NASA Astrophysics Data System (ADS)
Lee, Choonsik; Lee, Choonik; Han, Eun Young; Bolch, Wesley E.
2007-01-01
The effective dose recommended by the International Commission on Radiological Protection (ICRP) is the sum of organ equivalent doses weighted by corresponding tissue weighting factors, wT. ICRP is in the process of revising its 1990 recommendations on the effective dose where new values of organs and tissue weighting factors have been proposed and published in draft form for consultation by the radiological protection community. In its 5 June 2006 draft recommendations, new organs and tissues have been introduced in the effective dose which do not exist within the 1987 Oak Ridge National Laboratory (ORNL) phantom series (e.g., salivary glands). Recently, the investigators at University of Florida have updated the series of ORNL phantoms by implementing new organ models and adopting organ-specific elemental composition and densities. In this study, the effective dose changes caused by the transition from the current recommendation of ICRP Publication 60 to the 2006 draft recommendations were investigated for external photon irradiation across the range of ICRP reference ages (newborn, 1-year, 5-year, 10-year, 15-year and adult) and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO). Organ-absorbed doses were calculated by implementing the revised ORNL phantoms in the Monte Carlo radiation transport code, MCNPX2.5, after which effective doses were calculated under the 1990 and draft 2006 evaluation schemes of the ICRP. Effective doses calculated under the 2006 draft scheme were slightly higher than estimated under ICRP Publication 60 methods for all irradiation geometries exclusive of the AP geometry where an opposite trend was observed. The effective doses of the adult phantom were more greatly affected by the change in tissue weighting factors than that seen within the paediatric members of the phantom series. Additionally, dose conversion coefficients for newly identified radiosensitive organs—salivary glands, gall bladder, heart and prostate—were reported, as well as the brain, which was originally considered in ICRP Publication 60 as a member of the remainder category of the effective dose.
ICRP draft publication on 'radiological protection against radon exposure'.
Lecomte, J-F
2014-07-01
To control the main part of radon exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) recommends an integrated approach focused as far as possible on the management of the building or location in which radon exposure occurs whatever the purpose of the building and the types of its occupants. This approach is based on the optimisation principle and a graded approach according to the degree of responsibilities at stake, notably in workplace, as well as the level of ambition of the national authorities. The report which is being developed by the Committee 4 is considering the recently consolidated ICRP general recommendations, the new scientific knowledge about the radon risk and the experience gained by many organisations and countries in the control of radon exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
An improved MCNP version of the NORMAN voxel phantom for dosimetry studies.
Ferrari, P; Gualdrini, G
2005-09-21
In recent years voxel phantoms have been developed on the basis of tomographic data of real individuals allowing new sets of conversion coefficients to be calculated for effective dose. Progress in radiation studies brought ICRP to revise its recommendations and a new report, already circulated in draft form, is expected to change the actual effective dose evaluation method. In the present paper the voxel phantom NORMAN developed at HPA, formerly NRPB, was employed with MCNP Monte Carlo code. A modified version of the phantom, NORMAN-05, was developed to take into account the new set of tissues and weighting factors proposed in the cited ICRP draft. Air kerma to organ equivalent dose and effective dose conversion coefficients for antero-posterior and postero-anterior parallel photon beam irradiations, from 20 keV to 10 MeV, have been calculated and compared with data obtained in other laboratories using different numerical phantoms. Obtained results are in good agreement with published data with some differences for the effective dose calculated employing the proposed new tissue weighting factors set in comparison with previous evaluations based on the ICRP 60 report.
Management of radon: a review of ICRP recommendations.
Vaillant, Ludovic; Bataille, Céline
2012-09-01
This article proposes a review of past and current ICRP publications dealing with the management of radon exposures. Its main objective is to identify and discuss the driving factors that have been used by the Commission during the last 50 years so as to better appreciate current issues regarding radon exposure management. The analysis shows that major evolutions took place in very recent years. As far as the management of radon exposures is concerned, ICRP recommended, until ICRP Publication 103 (ICRP 2007 ICRP Publication 103; Ann. ICRP 37), to use action levels and to consider only exposures above these levels. The Commission has reviewed its approach and now proposes to manage any radon exposure through the application of the optimisation principle and associated reference levels. As far as the assessment of the radon risk is concerned, it appears that the successive changes made by ICRP did not have a strong impact on the values of radon gas concentration recommended as action levels either in dwellings or in workplaces. The major change occurred in late 2009 with the publication of the ICRP Statement on Radon, which acknowledged that the radon risk has been underestimated by a factor of 2, thus inducing a major revision of radon reference levels.
Application of the Commission's recommendations: the 2013-2017 Committee 4 programme of work.
Lochard, J
2015-06-01
Committee 4 of the International Commission on Radiological Protection (ICRP) is responsible for developing principles, recommendations, and guidance on the protection of people against radiation exposure, and to consider their practical application in all exposure situations. Currently, the Committee's efforts are focused on the completion of a series of future ICRP publications on the implementation of its 2007 Recommendations to the various existing exposure situations. A report on protection against radon exposure was published recently (ICRP Publication 126), and two documents on protection against cosmic radiation in aviation, and naturally occurring radioactive material are under development. The programme of work for the forthcoming 2013-2017 period comprises the update of ICRP Publication 109 on protection of people in emergency exposure situations, and the update of ICRP Publication 111 on protection of people living in long-term contaminated areas after a nuclear accident, as well as the development of a future ICRP publication on the ethics of radiological protection. It also includes the preparation of task groups on the application of the Commission's recommendations for contaminated sites from past activities and for surface and near-surface disposal of radioactive waste. Another important task for Committee 4 will be to develop a reflection on the tolerability of risk from radiation. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Basis for standards: ICRP activities.
Vano, E
2015-07-01
The purpose of this chapter is to describe work achieved recently by the International Commission on Radiological Protection (ICRP) and especially by Committee 3 (Protection in Medicine) and its use for standards. In March 1960, the Board of Governors of the International Atomic Energy Agency approved the Agency's 'Health and Safety Measures', stating that the Agency's 'Basic Safety Standards' (BSS) would be based, to the extent possible, on the recommendations of the ICRP. In a similar way, the Council of the European Union took into account the new recommendations of the ICRP when adopting the new Directive 2013/59/EURATOM that laid down BSS for protection against the dangers arising from exposure to ionising radiation. The new limit for the lens of the eyes for occupational exposures has been incorporated into these international standards and several articles dealing with medical exposures: justification, optimisation, recording patient doses, the use of diagnostic reference levels, training, accidental and unintended exposures, etc. have also been included in agreement with the ICRP recommendations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Annual limits on intake (ALI) values in ICRP 61 and 10 CFR Part 20 (1991)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, M.; Kearfott, K.J.
The newest major revision of Nuclear Regulatory Commission`s 10 CFR Part 20 (1991) incorporates the new dose methodology system, revised limits, and improved internal dose computations presented in International Commission on Radiation Protection (ICRP) Publication 30 (1979). A year before the issue of this revised 10 CFR Part 20, the ICRP dispatched Publication 61 (1990). This new ICRP report employed different dose limits, in addition to incorporating more recent biological information and variations in physiological and different tissue weighing factors for various organs. An investigation of the numerical differences in the Annual Limit on Intake (ALI) reported in this moremore » recent international regulations and those of the new regulations was thus undertaken. Overall means, medians, modes, maximum, minimum, and ranges of the percent changes are almost identical for ingestion and inhalation, although the percent difference between 10 CFR and ICRP Publication 61 showed minor differences for individual radionuclides. Approximately 334 of 1,351 radionuclides for inhalation and 173 of 771 radionuclides for ingestion have much less restrictive ALIs in the new ICRP recommendations than in the old, with some of those limits increased by at least a factor of two. Approximately 51% of the radionuclides for ingestion intake and 48% of radionuclides for inhalation intake showed changes of greater than 25%. The radionuclides observed to have much less restrictive ALIs are primarily the radionuclides of thorium, mercury, plutonium, uranium, and americium which have short effective clearance rates. While many countries have already applied the ICRP 61 recommendations to their radiation protection standards, using the ICRP 30 recommendation in the United States does not match the international standards even when the values of the ALIs are adjusted for differences in dose limits.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meinhold, C.B.
For many years, protecting the fetus has been a concern of the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP). Early recommendations focused on the possibility of a wide variety of detrimental developmental effects while later recommendations focused on the potential for severe mental retardation and/or reduction in the intelligence quotient (I.Q.). The latest recommendations also note that the risk of cancer for the fetus is probably two to three times greater per Sv than in the adult. For all these reasons, the NCRP and the ICRP have provided guidance to physiciansmore » on taking all reasonable steps to ascertain whether any woman requiring a radiological or nuclear medicine procedure is pregnant or nursing a child. The NCRP and the ICRP also advise the clinician to postpone such procedures until after delivery or cessation of nursing, if possible.« less
Lazo, Ted
2003-12-01
The Nuclear Energy Agency's (NEA's) Committee on Radiological Protection and Public Health (CRPPH) has collaborated closely with the ICRP in its efforts to develop new recommendations for radiological protection at the start of the 21st century. As part of this effort, the NEA organised, in collaboration with the ICRP, two fora to discuss the radiological protection of the environment (Taormina, February 2002) and the future policy for radiological protection (Lanzarote, April 2003). Both these meetings were attended by a broad representation of stakeholders. The CRPPH and other stakeholders universally appreciated the opportunity to speak directly with the ICRP on these important subjects. This report summarises the main conclusions made during these two meetings to advance the deliberations of the ICRP to create a new set of recommendations responsive to stakeholder needs, firmly rooted in science, and that can be implemented in a timely, efficient and cost-effective manner.
Müller, Wolfgang-Ulrich; Giussani, Augusto; Rühm, Werner; Lecomte, Jean-Francois; Harrison, John; Kreuzer, Michaela; Sobotzki, Christina; Breckow, Joachim
2016-08-01
ICRP suggested a strategy based on the distinction between a protection approach for dwellings and one for workplaces in the previous recommendations on radon. Now, the Commission recommends an integrated approach for the protection against radon exposure in all buildings irrespective of their purpose and the status of their occupants. The strategy of protection in buildings, implemented through a national action plan, is based on the application of the optimisation principle below a derived reference level in concentration (maximum 300 Bq m(-3)). A problem, however, arises that due to new epidemiological findings and application of dosimetric models, ICRP 115 (Ann ICRP 40, 2010) presents nominal probability coefficients for radon exposure that are approximately by a factor of 2 larger than in the former recommendations of ICRP 65 (Ann ICRP 23, 1993). On the basis of the so-called epidemiological approach and the dosimetric approach, the doubling of risk per unit exposure is represented by a doubling of the dose coefficients, while the risk coefficient of ICRP 103 (2007) remains unchanged. Thus, an identical given radon exposure situation with the new dose coefficients would result in a doubling of dose compared with the former values. This is of serious conceptual implications. A possible solution of this problem was presented during the workshop.
Radiological Protection in Space: Indication from the ICRP Task Group
NASA Astrophysics Data System (ADS)
Dietze, Günther
In 2007 the International Commission on Radiological Protection (ICRP) has established a Task Group (Radiation Protection in Space) dealing with the problems of radiation protection of astronauts in space missions. Its first task is a report on "Assessment of Radiation Exposure of Astronauts in Space". When the ICRP published its general recommendations for radiological protection in 2007 (ICRP Publication 103 following ICRP Publication 60 (1991)) it was obvious that these recommendations do not really consider the special situation of astronauts in space. The radiation field with its high content of charged particles of very high energies strongly differs from usual radiation fields on ground. For example, this has consequences for the assessment of doses in the body of astronauts. The ICRP Task Group has discussed this situation and the presentation will deal with some consequences for the concept of radiation dosimetry and radiological protection in space. This includes e. g. the assessment of organ doses and the application of the effective dose concept with its definition of radiation weighting factors. Radiation quality of high energy heavy ions may be defined different than usually performed on ground. An approach of using the quality factor concept in the definition of an "effective dose" is favored for application in space missions similar to the method proposed in NCRP Report 142. New data calculated on the basis of the reference anthropomorphic voxel phantoms recommended by ICRP support this procedure. Individual dosimetry is a further subject of discussion in the Task Group. While the operational dose equivalent quantities generally in use in radiation protection on ground are not helpful for applications in space, different procedures of the assessment of organ and effective doses are applied. The Task Group is dealing with this situation.
Broughton, J; Cantone, M C; Ginjaume, M; Shah, B
2013-12-01
This report was commissioned by the IRPA President to provide an assessment of the impact on members of IRPA Associate Societies of the introduction of ICRP recommendations for a reduced dose limit for the lens of the eye. The report summarises current practice and considers possible changes that may be required. Recommendations for further collaboration, clarification and changes to working practices are suggested.
Is ICRP guidance on the use of reference levels consistent?
Hedemann-Jensen, Per; McEwan, Andrew C
2011-12-01
In ICRP 103, which has replaced ICRP 60, it is stated that no fundamental changes have been introduced compared with ICRP 60. This is true except that the application of reference levels in emergency and existing exposure situations seems to be applied inconsistently, and also in the related publications ICRP 109 and ICRP 111. ICRP 103 emphasises that focus should be on the residual doses after the implementation of protection strategies in emergency and existing exposure situations. If possible, the result of an optimised protection strategy should bring the residual dose below the reference level. Thus the reference level represents the maximum acceptable residual dose after an optimised protection strategy has been implemented. It is not an 'off-the-shelf item' that can be set free of the prevailing situation. It should be determined as part of the process of optimising the protection strategy. If not, protection would be sub-optimised. However, in ICRP 103 some inconsistent concepts have been introduced, e.g. in paragraph 279 which states: 'All exposures above or below the reference level should be subject to optimisation of protection, and particular attention should be given to exposures above the reference level'. If, in fact, all exposures above and below reference levels are subject to the process of optimisation, reference levels appear superfluous. It could be considered that if optimisation of protection below a fixed reference level is necessary, then the reference level has been set too high at the outset. Up until the last phase of the preparation of ICRP 103 the concept of a dose constraint was recommended to constrain the optimisation of protection in all types of exposure situations. In the final phase, the term 'dose constraint' was changed to 'reference level' for emergency and existing exposure situations. However, it seems as if in ICRP 103 it was not fully recognised that dose constraints and reference levels are conceptually different. The use of reference levels in radiological protection is reviewed. It is concluded that the recommendations in ICRP 103 and related ICRP publications seem to be inconsistent regarding the use of reference levels in existing and emergency exposure situations.
Lochard, J
2016-12-01
Publication 111, published by the International Commission on Radiological Protection (ICRP) in 2009, provided the first recommendations for dealing with the long-term recovery phase after a nuclear accident. Its focus is on the protection of people living in long-term contaminated areas after a nuclear accident, drawing on the experience of the Belarus population, Cumbrian sheep farmers in the UK, and Sami reindeer herders in Norway affected by the fallout from Chernobyl. The ICRP dialogue initiative in Fukushima confirmed what had been identified after Chernobyl, namely the very strong concern for health, particularly that of children, loss of control over everyday life, apprehension about the future, disintegration of family life and of the social and economic fabric, and the threat to the autonomy and dignity of affected people. Through their testimonies and reflections, the participants of the 12 dialogue meetings shed light on this complex situation. The ICRP dialogue initiative also confirmed that the wellbeing of the affected people is at stake, and radiological protection must focus on rehabilitation of their living conditions. The challenge is to incorporate the important clarifications resulting from the ICRP dialogue initiative into the updated version of Publication 111 that is currently in development. This paper does not necessarily reflect the views of the International Commission on Radiological Protection.
Weiss, W; Larsson, C-M; McKenney, C; Minon, J-P; Mobbs, S; Schneider, T; Umeki, H; Hilden, W; Pescatore, C; Vesterlind, M
2013-06-01
This report updates and consolidates previous recommendations of the International Commission on Radiological Protection (ICRP) related to solid waste disposal (ICRP, 1985, 1997b, 1998). The recommendations given apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the ICRP system of radiological protection described in Publication 103 (ICRP, 2007) can be applied in the context of the geological disposal of long-lived solid radioactive waste. Although the report is written as a standalone document, previous ICRP recommendations not dealt with in depth in the report are still valid. The 2007 ICRP system of radiological protection evolves from the previous process-based protection approach relying on the distinction between practices and interventions by moving to an approach based on the distinction between three types of exposure situation: planned, emergency and existing. The Recommendations maintains the Commission's three fundamental principles of radiological protection namely: justification, optimisation of protection and the application of dose limits. They also maintain the current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They re-enforce the principle of optimisation of radiological protection, which applies in a similar way to all exposure situations, subject to restrictions on individual doses: constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment. This report describes the different stages in the life time of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences the application of the protection system over the different phases in the life time of a disposal facility is the level of oversight or 'watchful care' that is present. The level of oversight affects the capability to control the source, i.e. the waste and the repository, and to avoid or reduce potential exposures. Three main time frames are considered: time of direct oversight, when the disposal facility is being implemented and is under active supervision; time of indirect oversight, when the disposal facility is sealed and oversight is being exercised by regulators or special administrative bodies or society at large to provide additional assurance on behalf of society; and time of no oversight, when oversight is no longer exercised in case memory of the disposal facility is lost. Copyright © 2013. Published by Elsevier Ltd.
The mandate and work of ICRP Committee 3 on radiological protection in medicine.
Miller, D L; Martin, C J; Rehani, M M
2018-01-01
The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.
Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries: Neutrons
NASA Astrophysics Data System (ADS)
Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.; Hiller, M. M.
2017-09-01
With the introduction of new recommendations by ICRP Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors, and the introduction of reference sex-specific computational phantoms (ICRP Publication 110). Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue absorbed doses for caudal and cranial exposures to neutrons ranging in energy from 10-9 MeV to 10 GeV have been performed using the MCNP6 radiation transport code and the adult reference voxel phantoms of ICRP Publication 110. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above about 30 MeV the cranial and caudal values are greater.
A DISCUSSION ON DIFFERENT APPROACHES FOR ASSESSING LIFETIME RISKS OF RADON-INDUCED LUNG CANCER.
Chen, Jing; Murith, Christophe; Palacios, Martha; Wang, Chunhong; Liu, Senlin
2017-11-01
Lifetime risks of radon induced lung cancer were assessed based on epidemiological approaches for Canadian, Swiss and Chinese populations, using the most recent vital statistic data and radon distribution characteristics available for each country. In the risk calculation, the North America residential radon risk model was used for the Canadian population, the European residential radon risk model for the Swiss population, the Chinese residential radon risk model for the Chinese population, and the EPA/BEIR-VI radon risk model for all three populations. The results were compared with the risk calculated from the International Commission on Radiological Protection (ICRP)'s exposure-to-risk conversion coefficients. In view of the fact that the ICRP coefficients were recommended for radiation protection of all populations, it was concluded that, generally speaking, lifetime absolute risks calculated with ICRP-recommended coefficients agree reasonably well with the range of radon induced lung cancer risk predicted by risk models derived from epidemiological pooling analyses. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Organ and effective dose coefficients for cranial and caudal irradiation geometries: Neutrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.
Dose coefficients based on the recommendations of International Commission on Radiological Protection (ICRP) Publication 103 were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57 for the six reference irradiation geometries: anterior–posterior, posterior–anterior, right and left lateral, rotational and isotropic. In this work, dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and downward from above the head (cranial) using the ICRP 103 methodology were computed using the MCNP 6.1 radiation transport code. The dose coefficients were determined for neutrons ranging in energy from 10more » –9 MeV to 10 GeV. Here, at energies below about 500 MeV, the cranial and caudal dose coefficients are less than those for the six reference geometries reported in ICRP Publication 116.« less
Organ and effective dose coefficients for cranial and caudal irradiation geometries: Neutrons
Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.; ...
2016-08-29
Dose coefficients based on the recommendations of International Commission on Radiological Protection (ICRP) Publication 103 were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57 for the six reference irradiation geometries: anterior–posterior, posterior–anterior, right and left lateral, rotational and isotropic. In this work, dose coefficients for neutron irradiation of the body with parallel beams directed upward from below the feet (caudal) and downward from above the head (cranial) using the ICRP 103 methodology were computed using the MCNP 6.1 radiation transport code. The dose coefficients were determined for neutrons ranging in energy from 10more » –9 MeV to 10 GeV. Here, at energies below about 500 MeV, the cranial and caudal dose coefficients are less than those for the six reference geometries reported in ICRP Publication 116.« less
ICRP Publication 132: Radiological Protection from Cosmic Radiation in Aviation.
Lochard, J; Bartlett, D T; Rühm, W; Yasuda, H; Bottollier-Depois, J-F
2016-06-01
In this publication, the International Commission on Radiological Protection (ICRP) provides updated guidance on radiological protection from cosmic radiation in aviation, taking into account the current ICRP system of radiological protection, the latest available data on exposures in aviation, and experience gained worldwide in the management of exposures in aviation. The publication describes the origins of cosmic radiation, how it exposes passengers and aircraft crew, the basic radiological protection principles that apply to this existing exposure situation, and the available protective actions. For implementation of the optimisation principle, the Commission recommends a graded approach proportionate to the level of exposure that may be received by individuals. The objective is to keep the exposure of the most exposed individuals to a reasonable level. The Commission also recommends that information be disseminated to raise awareness about cosmic radiation, and to support informed decisions among concerned stakeholders.
MPC and ALI: their basis and their comparison
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, W.E. Jr.; Watson, E.C.
Radiation protection regulations in the United States have evolved from the recommendations of the International Commission on Radiological Protection (ICRP) and the National Council on Radiation Protection and Measurements (NCRP). In 1959, the ICRP issued Publication 2 which contained specific recommendations on dose rate limits, permissible body burdens, metabolic data for radionuclides, and maximum permissible concentrations (MPC) in air or water. Over the next 20 years, new information became available concerning the effects of radiation, the uptake and retention of radionuclides, and the radioactive decay schemes of parent radionuclides. To include this newer information, the ICRP issued Publication 30 inmore » 1978 to supersede Publication 2. One of the secondary limits defined in Publication 30 is the annual limit of intake (ALI). Radionuclide specific ALI values are intended to replace MPC values in determining whether or not ambient air and water concentrations are sufficiently low to maintain the dose to workers within accepted dose rate limits. In this paper, we discuss the derivation of MPC and ALI values, compare inhalation committed dose equivalent factors derived from ICRP Publications 2 and 30, and discuss the practical implications of using either MPC or ALI in determining compliance with occupational exposure limits. 6 references.« less
NASA Astrophysics Data System (ADS)
Schlattl, H.; Zankl, M.; Petoussi-Henss, N.
2007-04-01
A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.
Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons
Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.
2015-05-02
With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision ofmore » ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.« less
Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veinot, K. G.; Eckerman, K. F.; Hertel, N. E.
With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision ofmore » ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.« less
Weiss, W
2012-01-01
The report of International Commission on Radiological Protection (ICRP) Task Group 80 entitled 'Radiological protection in geological disposal of long-lived solid radioactive waste' updates and consolidates previous ICRP recommendations related to solid waste disposal (ICRP Publications 46, 77, and 81). The recommendations given in this report apply specifically to geological disposal of long-lived solid radioactive waste. The report explains how the 2007 system of radiological protection, described in ICRP Publication 103, can be applied in the context of the geological disposal of long-lived solid radioactive waste. The report is written as a self-standing document. It describes the different stages in the lifetime of a geological disposal facility, and addresses the application of relevant radiological protection principles for each stage depending on the various exposure situations that can be encountered. In particular, the crucial factor that influences application of the protection system over the different phases in the lifetime of a disposal facility is the level of oversight that is present. The level of oversight affects the capability to reduce or avoid exposures. Three main time frames have to be considered for the purpose of radiological protection: time of direct oversight when the disposal facility is being implemented and active oversight is taking place; time of indirect oversight when the disposal facility is sealed and indirect oversight is being exercised to provide additional assurance on behalf of the population; and time of no oversight when oversight is no longer exercised because memory is lost. Copyright © 2012. Published by Elsevier Ltd.
Kurihara, Chieko; Cho, Kunwoo; Toohey, Richard E
2016-12-01
The International Commission on Radiological Protection (ICRP) has established Task Group 94 (TG94) to develop a publication to clarify the ethical foundations of the radiological protection system it recommends. This TG identified four core ethical values which structure the system: beneficence and non-maleficence, prudence, justice, and dignity. Since the ICRP is an international organization, its recommendations and guidance should be globally applicable and acceptable. Therefore, first this paper presents the basic principles of the ICRP radiological protection system and its core ethical values, along with a reflection on the variation of these values in Western and Eastern cultural traditions. Secondly, this paper reflects upon how these values can be applied in difficult ethical dilemmas as in the case of the emergency and post-accident phases of a nuclear power plant accident, using the Fukushima case to illustrate the challenges at stake. We found that the core ethical values underlying the ICRP system of radiological protection seem to be quite common throughout the world, although there are some variations among various cultural contexts. Especially we found that 'prudence' would call for somewhat different implementation in each cultural context, balancing and integrating sometime conflicting values, but always with objectives to achieve the well-being of people, which is itself the ultimate aim of the radiological protection system.
ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.
Vano, E; Faulkner, K
2005-01-01
The International Commission on Radiological Protection (ICRP) has published two reports giving recommendations dealing with the avoidance of deterministic injuries in interventional radiology and the management of patient dose in digital radiology in 2001 and 2004, respectively. Another document, on radiation protection for cardiologists performing fluoroscopically guided procedures, will be produced during 2005. This paper highlights some of the topics of the published reports, their relevance to European legislation on medical exposures and the importance of radiation protection research in underpinning the ICRP task groups' work in to producing these documents. It is also anticipated that the results, obtained in the cardiology work package of the European research project, will be used in the new document on radiation protection for cardiologists.
Rühm, W; Walsh, L
2007-01-01
Currently, most analyses of the A-bomb survivors' solid tumour and leukaemia data are based on a constant neutron relative biological effectiveness (RBE) value of 10 that is applied to all survivors, independent of their distance to the hypocentre at the time of bombing. The results of these analyses are then used as a major basis for current risk estimates suggested by the International Commission on Radiological Protection (ICRP) for use in international safety guidelines. It is shown here that (i) a constant value of 10 is not consistent with weighting factors recommended by the ICRP for neutrons and (ii) it does not account for the hardening of the neutron spectra in Hiroshima and Nagasaki, which takes place with increasing distance from the hypocentres. The purpose of this paper is to present new RBE values for the neutrons, calculated as a function of distance from the hypocentres for both cities that are consistent with the ICRP60 neutron weighting factor. If based on neutron spectra from the DS86 dosimetry system, these calculations suggest values of about 31 at 1000 m and 23 at 2000 m ground range in Hiroshima, while the corresponding values for Nagasaki are 24 and 22. If the neutron weighting factor that is consistent with ICRP92 is used, the corresponding values are about 23 and 21 for Hiroshima and 21 and 20 for Nagasaki, respectively. It is concluded that the current risk estimates will be subject to some changes in view of the changed RBE values. This conclusion does not change significantly if the new doses from the Dosimetry System DS02 are used.
Medical and occupational dose reduction in pediatric barium meal procedures
NASA Astrophysics Data System (ADS)
Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Ledesma, J. A.; Legnani, A.; Bunick, A. P.; Sauzen, J.; Yagui, A.; Vosiak, P.
2017-11-01
Doses received in pediatric Barium Meal procedure can be rather high. It is possible to reduce dose values following the recommendations of the European Communities (EC) and the International Commission on Radiological Protection (ICRP). In the present work, the modifications of radiographic techniques made in a Brazilian hospital according to the EC and the ICRP recommendations and their influence on medical and occupational exposure are reported. The procedures of 49 patients before and 44 after the optimization were studied and air kerma-area product (PK,A) values and the effective doses were evaluated. The occupational equivalent doses were measured next to the eyes, under the thyroid shield and on each hand of both professionals who remained inside the examination room. The implemented modifications reduced by 70% and 60% the PK,A and the patient effective dose, respectively. The obtained dose values are lower than approximately 75% of the results from similar studies. The occupational annual equivalent doses for all studied organs became lower than the limits set by the ICRP. The equivalent doses in one examination were on average below than 75% of similar studies.
Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen
2010-12-01
The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... (rifaximin-550). The recommendations provide specific guidance on the design of bioequivalence (BE) studies... studies to support ANDAs for rifaximin-200 (Draft Rifaximin-200 BE Recommendations). FDA is now issuing a...] Draft Guidance for Industry on Bioequivalence Recommendations for Rifaximin Tablets; Availability AGENCY...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-11
...] Draft Guidance for Industry on Recommendations for Preparation and Submission of Animal Food Additive...) entitled ``Recommendations for Preparation and Submission of Animal Food Additive Petitions.'' This draft... guidance for industry (GFI 221) entitled ``Recommendations for Preparation and Submission of Animal Food...
THE SCIENCE BEHIND THE ICRP 2005 RECOMMENDATIONS
The ICRP 2005 Recommendations are stated to be "based on a simple, but widely applicable, general system of protection that will clarify its objectives and will provide a basis for the more formal systems needed by operating managements and regulators". The Recommendati...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-30
... Radiological Protection; Recommendations on the Annual Dose Limit to the Lens of the Eye AGENCY: Nuclear... Protection (ICRP) recommendations for the limitation of annual dose to the lens of the eye. This significant... might be lower than previously considered. For the lens of the eye, the threshold in absorbed dose for...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-26
...] (Formerly Docket No. 2007D-0168) Draft Guidance for Industry on Bioequivalence Recommendations for... industry entitled ``Draft Guidance on Risperidone.'' The guidance provides specific recommendations on the design of bioequivalence (BE) studies to support abbreviated new drug applications (ANDAs) for...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... Bioequivalence Recommendations; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY... draft product-specific bioequivalence (BE) recommendations. The recommendations provide product-specific guidance on the design of BE studies to support abbreviated new drug applications (ANDAs). In the Federal...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-19
... Draft Recommendations of the Healthcare Personnel Influenza Vaccination Subgroup for Consideration by... Influenza Vaccination in Healthcare Personnel AGENCY: Department of Health and Human Services, Office of the... ASH has charged the NVAC with developing recommended strategies for annually achieving 90% influenza...
Dose estimation of eye lens for interventional procedures in diagnosis
NASA Astrophysics Data System (ADS)
Liu, Yu-Rong; Huang, Chia-Yu; Hsu, Ching-Han; Hsu, Fang-Yuh
2017-11-01
The International Commission on Radiological Protection (ICRP) recommended that the equivalent dose limit for the lens of the eye be decreased from 150 mSv/y (ICRP, 2007) to 20 mSv/y averaged over five years (ICRP, 2011). How to accurately measure the eye-lens dose has, therefore, been an issue of interest recently. Interventional radiologists are at a higher risk of radiation-induced eye injury, such as cataracts, than all other occupational radiation workers. The main objective of this study is to investigate the relationship between the doses to the eye lenses of interventional radiologists measured by different commercial eye-lens dosimeters. This study measured a reference eye-lens dose, which involved placing thermoluminescent dosimeter (TLD) chips at the surface of the eye of the Rando Phantom, and the TLD chips were covered by a 3-mm-thick tissue-equivalent bolus. Commercial eye-lens dosimeters, such as a headband dosimeter and standard personnel dose badges, were placed at the positions recommended by the manufacturers. The results show that the personnel dose badge is not an appropriate dosimeter for evaluating eye-lens dose. Dose deviations for different dosimeters are discussed and presented in this study.
Bouffler, Simon; Ainsbury, Elizabeth; Gilvin, Phil; Harrison, John
2012-12-01
This paper presents the response of the Health Protection Agency (HPA) to the 2011 statement from the International Commission on Radiological Protection (ICRP) on tissue reactions and recommendation of a reduced dose limit for the lens of the eye. The response takes the form of a brief review of the most recent epidemiological and mechanistic evidence. This is presented together with a discussion of dose limits in the context of the related risk and the current status of eye dosimetry, which is relevant for implementation of the limits. It is concluded that although further work is desirable to quantify better the risk at low doses and following protracted exposures, along with research into the mechanistic basis for radiation cataractogenesis to inform selection of risk projection models, the HPA endorses the conclusion reached by the ICRP in their 2011 statement that the equivalent dose limit for the lens of the eye should be reduced from 150 to 20 mSv per year, averaged over a five year period, with no year's dose exceeding 50 mSv.
Use of the ICRP system for the protection of marine ecosystems.
Telleria, D; Cabianca, T; Proehl, G; Kliaus, V; Brown, J; Bossio, C; Van der Wolf, J; Bonchuk, I; Nilsen, M
2015-06-01
The International Commission on Radiological Protection (ICRP) recently reinforced the international system of radiological protection, initially focused on humans, by identifying principles of environmental protection and proposing a framework for assessing impacts of ionising radiation on non-human species, based on a reference flora and fauna approach. For this purpose, ICRP developed dosimetric models for a set of Reference Animals and Plants, which are representative of flora and fauna in different environments (terrestrial, freshwater, marine), and produced criteria based on information on radiation effects, with the aim of evaluating the level of potential or actual radiological impacts, and as an input for decision making. The approach developed by ICRP for flora and fauna is consistent with the approach used to protect humans. The International Atomic Energy Agency (IAEA) includes considerations on the protection of the environment in its safety standards, and is currently developing guidelines to assess radiological impacts based on the aforementioned ICRP approach. This paper presents the method developed by IAEA, in a series of meetings with international experts, to enable assessment of the radiological impact to the marine environment in connection with the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (London Convention 1972). This method is based on IAEA's safety standards and ICRP's recommendations, and was presented in 2013 for consideration by representatives of the contracting parties of the London Convention 1972; it was approved for inclusion in its procedures, and is in the process of being incorporated into guidelines. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
... and recommendations could be found on the Web at http://www.hhs.gov/nvpo/nvac/subgroups/adultimmunization . The Web address where the draft report and recommendations can be found is http://www.hhs.gov...) The draft report and recommendations are available on the Web at http://www.hhs.gov/nvpo/nvac...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-10
...] Draft Guidance for Industry on Bioequivalence Recommendations for Fluticasone Propionate; Salmeterol... ``Bioequivalence Recommendations for Fluticasone Propionate; Salmeterol Xinafoate.'' The recommendations provide specific guidance on the design of bioequivalence (BE) studies to support abbreviated new drug applications...
Sato, Tatsuhiko; Endo, Akira; Zankl, Maria; Petoussi-Henss, Nina; Niita, Koji
2009-04-07
The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation and tissue weighting factors, w(R) and w(T), respectively, as revised in ICRP Publication 103 were employed. The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of the absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. By comparing these data with the corresponding data for the effective dose, we found that the numerical compatibilities of the revised w(R) with the Q(L) and Q(y) relationships are fairly established. The calculated data of these dose conversion coefficients are indispensable for constructing the radiation protection systems based on the new recommendations given in ICRP103 for aircrews and astronauts, as well as for workers in accelerators and nuclear facilities.
Thilander-Klang, Anne; Ylhan, Betȕl; Lofthag-Hansen, Sara; Ekestubbe, Annika
2016-01-01
Objective: During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Methods: Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. Results: The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a full-mouth intraoral examination was 15 μSv and for panoramic radiography, the effective dose was in the range of 19–75 μSv, depending on the panoramic equipment used. Conclusion: The effective dose from a full-mouth intraoral examination is lower and that from panoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk–benefit profile of this technique must be assessed for the individual patient. Advances in knowledge: The effective dose of radiation from panoramic radiography is higher than previously reported and there is large variability in the delivered radiation dosage among the different types of equipment used. PMID:27452261
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
...] Draft Guidance for Industry on Bioequivalence Recommendations for Iron Sucrose Injection; Availability... Recommendations for Iron Sucrose.'' The recommendations provide specific guidance on the design of bioequivalence (BE) studies to support abbreviated new drug applications (ANDAs) for iron sucrose injection. DATES...
78 FR 35956 - Utah Resource Advisory Council Subgroup Conference Call
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... BLM-Utah's draft three-year National Conservation Lands Strategy. In May 2013, the RAC provided the BLM-Utah State Director with recommended changes to the draft strategy and this meeting was held to discuss how BLM-Utah has incorporated their recommendations into a revised draft strategy. A public...
Homma, T; Takahara, S; Kimura, M; Kinase, S
2015-06-01
Radiation protection issues on preparedness and response for a severe nuclear accident are discussed in this paper based on the experiences following the accident at Fukushima Daiichi nuclear power plant. The criteria for use in nuclear emergencies in the Japanese emergency preparedness guide were based on the recommendations of International Commission of Radiological Protection (ICRP) Publications 60 and 63. Although the decision-making process for implementing protective actions relied heavily on computer-based predictive models prior to the accident, urgent protective actions, such as evacuation and sheltering, were implemented effectively based on the plant conditions. As there were no recommendations and criteria for long-term protective actions in the emergency preparedness guide, the recommendations of ICRP Publications 103, 109, and 111 were taken into consideration in determining the temporary relocation of inhabitants of heavily contaminated areas. These recommendations were very useful in deciding the emergency protective actions to take in the early stages of the Fukushima accident. However, some suggestions have been made for improving emergency preparedness and response in the early stages of a severe nuclear accident. © The Chartered Institution of Building Services Engineers 2014.
Ozaki, Y.; Kaida, A.; Miura, M.; Nakagawa, K.; Toda, K.; Yoshimura, R.; Sumi, Y.; Kurabayashi, T.
2017-01-01
Abstract Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. PMID:28339846
History and Organizations for Radiological Protection.
Kang, Keon Wook
2016-02-01
International Commission on Radiological Protection (ICRP), an independent international organization established in 1925, develops, maintains, and elaborates radiological protection standards, legislation, and guidelines. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) provides scientific evidence. World Health Organization (WHO) and International Atomic Energy Agency (IAEA) utilise the ICRP recommendations to implement radiation protection in practice. Finally, radiation protection agencies in each country adopt the policies, and adapt them to each situation. In Korea, Nuclear Safety and Security Commission is the governmental body for nuclear safety regulation and Korea Institute of Nuclear Safety is a public organization for technical support and R&D in nuclear safety and radiation protection.
Radiological protection issues arising during and after the Fukushima nuclear reactor accident.
González, Abel J; Akashi, Makoto; Boice, John D; Chino, Masamichi; Homma, Toshimitsu; Ishigure, Nobuhito; Kai, Michiaki; Kusumi, Shizuyo; Lee, Jai-Ki; Menzel, Hans-Georg; Niwa, Ohtsura; Sakai, Kazuo; Weiss, Wolfgang; Yamashita, Shunichi; Yonekura, Yoshiharu
2013-09-01
Following the Fukushima accident, the International Commission on Radiological Protection (ICRP) convened a task group to compile lessons learned from the nuclear reactor accident at the Fukushima Daiichi nuclear power plant in Japan, with respect to the ICRP system of radiological protection. In this memorandum the members of the task group express their personal views on issues arising during and after the accident, without explicit endorsement of or approval by the ICRP. While the affected people were largely protected against radiation exposure and no one incurred a lethal dose of radiation (or a dose sufficiently large to cause radiation sickness), many radiological protection questions were raised. The following issues were identified: inferring radiation risks (and the misunderstanding of nominal risk coefficients); attributing radiation effects from low dose exposures; quantifying radiation exposure; assessing the importance of internal exposures; managing emergency crises; protecting rescuers and volunteers; responding with medical aid; justifying necessary but disruptive protective actions; transiting from an emergency to an existing situation; rehabilitating evacuated areas; restricting individual doses of members of the public; caring for infants and children; categorising public exposures due to an accident; considering pregnant women and their foetuses and embryos; monitoring public protection; dealing with 'contamination' of territories, rubble and residues and consumer products; recognising the importance of psychological consequences; and fostering the sharing of information. Relevant ICRP Recommendations were scrutinised, lessons were collected and suggestions were compiled. It was concluded that the radiological protection community has an ethical duty to learn from the lessons of Fukushima and resolve any identified challenges. Before another large accident occurs, it should be ensured that inter alia: radiation risk coefficients of potential health effects are properly interpreted; the limitations of epidemiological studies for attributing radiation effects following low exposures are understood; any confusion on protection quantities and units is resolved; the potential hazard from the intake of radionuclides into the body is elucidated; rescuers and volunteers are protected with an ad hoc system; clear recommendations on crisis management and medical care and on recovery and rehabilitation are available; recommendations on public protection levels (including infant, children and pregnant women and their expected offspring) and associated issues are consistent and understandable; updated recommendations on public monitoring policy are available; acceptable (or tolerable) 'contamination' levels are clearly stated and defined; strategies for mitigating the serious psychological consequences arising from radiological accidents are sought; and, last but not least, failures in fostering information sharing on radiological protection policy after an accident need to be addressed with recommendations to minimise such lapses in communication.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
... Draft Recommendations of the Vaccine Safety Working Group for Consideration by the National Vaccine Advisory Committee on the Federal Vaccine Safety System AGENCY: National Vaccine Program Office, Office of.... ACTION: Notice. SUMMARY: The National Vaccine Advisory Committee (NVAC) was established in 1987 to comply...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-07
... Recommended Interim Preliminary Remediation Goals for Dioxin in Soil at CERCLA and RCRA Sites AGENCY... Recommended Interim Preliminary Remediation Goals for Dioxin in Soil at Comprehensive Environmental Response... interim PRGs for dioxin in soil. These draft recommended interim PRGs were calculated using existing, peer...
77 FR 69619 - Draft Recommendations of Joint Outreach Team
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-20
... Team AGENCY: Western Area Power Administration, DOE. ACTION: Notice of Availability of draft recommendations of Western/DOE Joint Outreach Team. SUMMARY: The Western Area Power Administration (Western), a... recommendations of the Western/DOE Joint Outreach Team (JOT) for review and comment by Western's customers, Tribes...
Ozaki, Y; Watanabe, H; Kaida, A; Miura, M; Nakagawa, K; Toda, K; Yoshimura, R; Sumi, Y; Kurabayashi, T
2017-07-01
Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phantoms to estimate whole-body exposure from oral brachytherapy. We used a Particle and Heavy Ion Transport code System (PHITS) to model oral brachytherapy with 192Ir hairpins and 198Au grains and to perform a Monte Carlo simulation on the ICRP adult reference computational phantoms. To confirm the simulations, we also computed local dose distributions from these small sources, and compared them with the results from Oncentra manual Low Dose Rate Treatment Planning (mLDR) software which is used in day-to-day clinical practice. We successfully obtained data on absorbed dose for each organ in males and females. Sex-averaged equivalent doses were 0.547 and 0.710 Sv with 192Ir hairpins and 198Au grains, respectively. Simulation with PHITS was reliable when compared with an alternative computational technique using mLDR software. We concluded that the absorbed dose for each organ and whole-body exposure from oral brachytherapy can be estimated with Monte Carlo simulation using PHITS on ICRP reference phantoms. Effective doses for patients with oral cancer were obtained. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-06
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2007-D-0369] Draft Guidance for Industry on Bioequivalence Recommendations for Iron Sucrose; Availability AGENCY... guidance, FDA recommended an in vivo fasting BE study with pharmacokinetic endpoints and in vitro studies...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... Recommendations for Mesalamine.'' The recommendations provide specific guidance on the design of bioequivalence... suppositories: A fasting BE study with pharmacokinetic endpoints and comparative in vitro studies (melting point...). The draft guidance, when finalized, will represent the Agency's current thinking on the design of BE...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
...] Draft Guidance for Industry: Recommendations for Premarket Notification (510(k)) Submissions for Nucleic... ``Guidance for Industry: Recommendations for Premarket Notification (510(k)) Submissions for Nucleic Acid... submitters and FDA reviewers in preparing and reviewing 510(k) submissions for nucleic acid-based HLA test...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... Recommendations; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and...-specific bioequivalence (BE) recommendations. The recommendations provide product-specific guidance on the design of BE studies to support abbreviated new drug applications (ANDAs). In the Federal Register of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
... Recommendations; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and...-specific bioequivalence (BE) recommendations. The recommendations provide product-specific guidance on the design of BE studies to support abbreviated new drug applications (ANDAs). In the Federal Register of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-22
... Recommendations; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and...-specific bioequivalence (BE) recommendations. The recommendations provide product-specific guidance on the design of BE studies to support abbreviated new drug applications (ANDAs). In the Federal Register of...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
... document describes FDA's recommendations concerning 510(k) submissions for various types of in vitro.... SUPPLEMENTARY INFORMATION: I. Background This draft guidance includes recommendations concerning 510(k...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-13
... though we have not requested comparative in vitro studies, in vitro studies outlined in the 2002 guidance.... The recommendations provide specific guidance on the design of bioequivalence (BE) studies to support... draft guidance for industry on the Agency's recommendations for BE studies to support ANDAs for...
Radiological protection in computed tomography and cone beam computed tomography.
Rehani, M M
2015-06-01
The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Bolch, W E; Dietze, G; Petoussi-Henss, N; Zankl, M
2015-06-01
Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
78 FR 56718 - Draft Guidance for Industry on Bioanalytical Method Validation; Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
...] Draft Guidance for Industry on Bioanalytical Method Validation; Availability AGENCY: Food and Drug... availability of a draft guidance for industry entitled ``Bioanalytical Method Validation.'' The draft guidance is intended to provide recommendations regarding analytical method development and validation for the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
...) protect the head, neck and spine of all children transported in ground ambulances. By ensuring that these... transport (newborn with Mother, multiple children, etc.). The full text of the recommendations and the draft...
Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2009-01-13
In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... Texts for Use in the International Conference on Harmonisation Regions; Annex 13 on Bulk Density and... availability of a draft guidance entitled ``Q4B Evaluation and Recommendation of Pharmacopoeial Texts for Use...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
... Paliperidone Palmitate Extended-Release Injectable Suspension; Availability AGENCY: Food and Drug...) studies to support abbreviated new drug applications (ANDAs) for paliperidone palmitate extended-release... the availability of revised draft BE recommendations for paliperidone palmitate extended-release...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-19
...] Draft Guidance for Industry on Self-Selection Studies for Nonprescription Drug Products; Availability...) is announcing the availability of a draft guidance for industry entitled ``Self-Selection Studies for Nonprescription Drug Products.'' The draft guidance is intended to provide recommendations to industry on the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Posas, Paula J., E-mail: pjposas@gmail.co
2011-04-15
The Protocol on Strategic Environmental Assessment (SEA) to the United Nations Economic Commission for Europe (UNECE) Espoo Convention came into force on 11 July 2010. This Protocol, to which the European Union is party, gives a legal basis for enhanced attention to human health in the SEA process. In this context, the United Kingdom's (UK's) 2007 Draft Guidance on Health in Strategic Environmental Assessment represents an important early government-led effort to bring health issues and public health considerations more significantly into the SEA process. Since the UK is a worldwide leader in environmental and various other types of impact assessment,more » and since other countries may eventually consider its example in efforts to meet UNECE SEA Protocol requirements, scrutiny of its outputs is warranted. This paper thus examines the UK's Draft Guidance from both HIA academic and practitioner perspectives. First it assesses the extent to which the Draft Guidance reflects recent issues and lessons learned in the academic literature. In order to make the assessment, a meta-analysis of 70 HIA-related peer-reviewed articles was undertaken to extract authors' priority recommendations. These recommendations were subsequently compared with the contents of the Draft Guidance. Secondly, the Draft Guidance was assessed for its accordance with recommendations of the UNECE SEA Protocol background paper written by two HIA practitioners. Overall, the Draft Guidance's accordance with both sets of recommendations was found to be high, with only a few easily-remedied gaps. This evaluation suggests that the UK's Draft Guidance can be a useful starting point in the creation of future guidance on health in SEA in both the UK and other countries.« less
Hanford Technical Basis for Multiple Dosimetry Effective Dose Methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, Robin L.; Rathbone, Bruce A.
2010-08-01
The current method at Hanford for dealing with the results from multiple dosimeters worn during non-uniform irradiation is to use a compartmentalization method to calculate the effective dose (E). The method, as documented in the current version of Section 6.9.3 in the 'Hanford External Dosimetry Technical Basis Manual, PNL-MA-842,' is based on the compartmentalization method presented in the 1997 ANSI/HPS N13.41 standard, 'Criteria for Performing Multiple Dosimetry.' With the adoption of the ICRP 60 methodology in the 2007 revision to 10 CFR 835 came changes that have a direct affect on the compartmentalization method described in the 1997 ANSI/HPS N13.41more » standard, and, thus, to the method used at Hanford. The ANSI/HPS N13.41 standard committee is in the process of updating the standard, but the changes to the standard have not yet been approved. And, the drafts of the revision of the standard tend to align more with ICRP 60 than with the changes specified in the 2007 revision to 10 CFR 835. Therefore, a revised method for calculating effective dose from non-uniform external irradiation using a compartmental method was developed using the tissue weighting factors and remainder organs specified in 10 CFR 835 (2007).« less
Cosmic radiation in aviation: radiological protection of Air France aircraft crew.
Desmaris, G
2016-06-01
Cosmic radiation in aviation has been a concern since the 1960s, and measurements have been taken for several decades by Air France. Results show that aircraft crew generally receive 3-4 mSv y(-1) for 750 boarding hours. Compliance with the trigger level of 6 mSv y(-1) is achieved by route selection. Work schedules can be developed for pregnant pilots to enable the dose to the fetus to be kept below 1 mSv. Crew members are informed of their exposition and the potential health impact. The upcoming International Commission on Radiological Protection (ICRP) report on cosmic radiation in aviation will provide an updated guidance. A graded approach proportionate with the time of exposure is recommended to implement the optimisation principle. The objective is to keep exposures of the most exposed aircraft members to reasonable levels. ICRP also recommends that information about cosmic radiation be disseminated, and that awareness about cosmic radiation be raised in order to favour informed decision-making by all concerned stakeholders. © The International Society for Prosthetics and Orthotics.
Ethical foundations of the radiological protection system.
Cho, K W
2016-06-01
The International Commission on Radiological Protection (ICRP) has established Task Group 94 under Committee 4 to develop a report on the ethical foundations of the system of radiological protection. The aim of this report is to consolidate the basis of ICRP recommendations, to improve understanding of the system, and to provide a basis for communication on radiation risk and its perception. Through a series of workshops organised by the Commission in cooperation with the International Radiation Protection Association and its associate societies involving radiological protection professionals and specialists of ethics around the world, Task Group 94 has identified the key ethical and social values underpinning the system of radiological protection. The purpose of eliciting the ethical principles and values of the radiological protection system is not only to clarify the rationale for recommendations made by the Commission, but also to assist in discussions related to its practical implementation. A clear understanding of the ethical principles will help resolve dilemmas caused by potential conflicts in actions that might be considered, or decisions that must be made. © The International Society for Prosthetics and Orthotics.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-03
... in order to be excluded from the organic certification requirements of Part 205. The NOSB recommended... handling operations that are or are not excluded from organic certification. The draft guidance proposes... excluded from certification and, therefore, must be certified organic operations. \\1\\ NOSB Recommendation...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0395] Draft Guidance for Industry and Food and Drug Administration Staff; Recommendations for Premarket Notifications for Lamotrigine and Zonisamide Assays; Availability AGENCY: Food and Drug Administration, HHS...
The New US Preventive Services Task Force "C" Draft Recommendation for Prostate Cancer Screening.
Cooperberg, Matthew R
2017-09-01
The US Preventive Services Task Force has issued a new draft guideline, with a "C" recommendation that men aged 55-69 yr should be informed about the benefits and harms of screening for prostate cancer, and offered prostate-specific antigen testing if they choose it. For men aged ≥70 yr, the recommendation remains "D", or "do not screen." This draft represents substantial progress in the right direction towards offering men a fair opportunity to discuss the risks and benefits of screening with their primary care providers. However, the evidence review underlying the draft remains fundamentally inadequate, leading to biased presentations of both benefits and harms of screening. The final guideline and future revisions should reflect formal engagement with subject matter experts to optimize the advise given to men and their physicians. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-06
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2007-D-0433; (formerly Docket No. 2007D-0169)] Draft Guidance for Industry on Bioequivalence Recommendation for...) Acceptable fasting and fed bioequivalence studies on the 25 mg strength, (2) proportional similarity of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0928] Draft Guidance for Industry on Recommendations for Preparation and Submission of Animal Food Additive... Preparation and Submission of Animal Food Additive Petitions.'' DATES: Submit either electronic or written...
An International Approach to Enhancing a National Guideline on Driving and Dementia.
Rapoport, Mark J; Chee, Justin N; Carr, David B; Molnar, Frank; Naglie, Gary; Dow, Jamie; Marottoli, Richard; Mitchell, Sara; Tant, Mark; Herrmann, Nathan; Lanctôt, Krista L; Taylor, John-Paul; Donaghy, Paul C; Classen, Sherrilene; O'Neill, Desmond
2018-03-12
The purpose of this study was to update a national guideline on assessing drivers with dementia, addressing limitations of previous versions which included a lack of developmental rigor and stakeholder involvement. An international multidisciplinary team reviewed 104 different recommendations from 12 previous guidelines on assessing drivers with dementia in light of a recent review of the literature. Revised guideline recommendations were drafted by consensus. A preliminary draft was sent to specialist physician and occupational therapy groups for feedback, using an a priori definition of 90% agreement as consensus. The research team drafted 23 guideline recommendations, and responses were received from 145 stakeholders. No recommendation was endorsed by less than 80% of respondents, and 14 (61%) of the recommendations were endorsed by more than 90%.The recommendations are presented in the manuscript. The revised guideline incorporates the perspectives of consensus of an expert group as well as front-line clinicians who regularly assess drivers with dementia. The majority of the recommendations were based on evidence at the level of expert opinion, revealing gaps in the evidence and future directions for research.
ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3.
Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Marsh, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Blanchardon, E; Gregoratto, D; Harrison, J D
2017-12-01
The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988) and Publication 68 (ICRP, 1994). In addition, new data are now available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. OIR Part 1 has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. OIR Part 2 (ICRP, 2016), this current publication and upcoming publications in the OIR series (Parts 4 and 5) provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv Bq−1 intake) for inhalation and ingestion, tables of committed effective dose per content (Sv Bq−1 measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of publications contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. This third publication in the series provides the above data for the following elements: ruthenium (Ru), antimony (Sb), tellurium (Te), iodine (I), caesium (Cs), barium (Ba), iridium (Ir), lead (Pb), bismuth (Bi), polonium (Po), radon (Rn), radium (Ra), thorium (Th), and uranium (U).
76 FR 23845 - Draft Regulatory Guide: Issuance, Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
... draft guide in the agency's ``Regulatory Guide'' series. This series was developed to describe and make... approach that the staff of the NRC considers acceptable for use in developing an appropriate surveillance... steel. The recommendations described in this draft regulatory guide are an approach acceptable to the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
...] Draft Guidance for Industry on Providing Submissions in Electronic Format--Standardized Study Data... Submissions in Electronic Format--Standardized Study Data.'' This draft guidance establishes FDA's recommendation that sponsors and applicants submit nonclinical and clinical study data in a standardized...
US Food and Drug Administration draft recommendations on radioactive contamination of food
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, D.L.
Recommendations on accidental radioactive contamination of human food were issued in 1982 by the Food and Drug Administration (FDA). The recommendations provided guidance to State and local government officials in the exercise of their respective authorities, and were applicable to emergency response planning and to the conduct of radiation protection activities associated with the production, processing, distribution, and use of human food accidentally contaminated with radioactive material. Review of the 1982 FDA recommendations, stimulated by the events following the 1986 accident at Chernobyl, indicated that it would be appropriate to update the recommendations to incorporate newer scientific information and radiationmore » protection philosophy, to include experience gained since 1982, and to take into account international advances. This paper presents a brief outline of the FDA`s approach to its draft revision. the most recent draft was circulated for interagency review in November 1994. Modification made in response to the comments received are included in this paper. 20 refs., 6 tabs.« less
This is a draft of the recommendations that that Assumable Waters Subcommittee will present to NACEPT on May 10. It should be considered a draft until it is approved and transmitted to the EPA by NACEPT
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-26
... components, including Source Plasma. The guidance announced in this notice replaces the draft guidance... before it begins work on the final version of the guidance, submit either electronic or written comments... the SUPPLEMENTARY INFORMATION section for electronic access to the draft guidance document. Submit...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-11
... Product Container Is Not Made With Natural Rubber Latex.'' The purpose of this draft guidance is to make recommendations on the appropriate language to include in the labeling of a medical product to convey that natural... Products To Inform Users That the Product or Product Container Is Not Made With Natural Rubber Latex...
1998-01-01
C-Arms and Digital Fluorscopy ....... ............................. 6 Image Intensifier III) Input Exposure Rates and Exposures...Setup for ESE Measurements in Conventional Radiography .................. 3 Figure 2: Setup tor IP ;R M easurem ents...exposure from dental procedures. An area of dental radiography which has not been well addressed is the dose received during panoramic or panalipse
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-31
..., including Source Plasma, with recommendations intended to assist with determining which reporting mechanism... final version of the guidance, submit either electronic or written comments on the draft guidance by... INFORMATION section for electronic access to the draft guidance document. Submit electronic comments on the...
Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms
NASA Astrophysics Data System (ADS)
Tat Nguyen, Thang; Yeom, Yeon Soo; Kim, Han Sung; Wang, Zhao Jun; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Chung, Beom Sun
2015-11-01
The dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.
Kravchik, T; Oved, S; Paztal-Levy, O; Pelled, O; Gonen, R; German, U; Tshuva, A
2008-01-01
Inhalation is the main route of internal exposure to radioactive aerosols in the nuclear industry. To assess the radiation dose from the intake of these aerosols, it is necessary to know their physical (aerodynamic diameter distribution) and chemical (dissolution rate in extracellular lung fluid) characteristics. Air samples were taken from the uranium processing plant at the Nuclear Research Center, Negev. Measurements of aerodynamic diameter distribution using a cascade impactor indicated an average activity median aerodynamic diameter value close to 5 microm, in accordance with the recent recommended values of International Commission on Radiological Protection (ICRP) model. Solubility profiles of these aerosols were determined by performing in vitro solubility tests over 100 d in a simultant solution of the extracellular fluid. The tests indicated that the uranium aerosols should be assigned to an absorption between Types M and S (as defined by the ICRP Publication 66 model).
2006-01-01
This report compiles the various numerical protection level values published by the International Commission on Radiological Protection (ICRP) since its 1990 Recommendations (Publication 60). Several terms are used to denominate the protection levels: individual dose limit, 'maximum' individual dose, dose constraint, exemption level, exclusion level, action level, or intervention level. The reasons provided by the Commission for selecting the associated numerical values is quoted as far as available. In some cases the rationale is not totally explicit in the original ICRP report concerned; in such cases the Task Group that prepared the present report have proposed their own interpretation. Originally, this report was prepared by a Task Group at CEPN, a French research and development center, in behalf of IRSN, a French public expert body engaged in radiological protection and nuclear safety. It is published here with kind permission by CEPN and IRSN.
76 FR 36542 - Draft Guidance for Industry and Food and Drug Administration Staff: The Content of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-22
...The Food and Drug Administration (FDA) is announcing the availability of the draft guidance document entitled ``Draft Guidance for Industry and Food and Drug Administration Staff: The Content of Investigational Device Exemption (IDE) and Premarket Approval (PMA) Applications for Low Glucose Suspend (LGS) Device Systems.'' This draft guidance document provides industry and Agency staff with recommendations that are intended to improve the safety and effectiveness of LGS Device Systems. This draft guidance is not final nor is it in effect at this time.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... consider comments and recommendations on the draft guidebook, which is available at: http://www1.eere... draft guidebook is available at: http://www1.eere.energy.gov/femp/pdfs/largereguide.pdf . DOE will... DATES section. More information on DOE's FEMP is available at: http://www1.eere.energy.gov/femp...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... or on Medicated Feed or Drinking Water of Food-Producing Animals: Recommendations for Drug Sponsors for Voluntarily Aligning Product Use Conditions With GFI 209; Availability AGENCY: Food and Drug... availability of a draft guidance for industry (draft GFI 213) entitled ``New Animal Drugs and New Animal Drug...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manabe, K.; Endo, Akira; Eckerman, Keith F
2010-03-01
The impact a revision of nuclear decay data had on dose coefficients was studied using data newly published in ICRP Publication 107 (ICRP 107) and existing data from ICRP Publication 38 (ICRP 38). Committed effective dose coefficients for occupational inhalation of radionuclides were calculated using two sets of decay data with the dose and risk calculation software DCAL for 90 elements, 774 nuclides and 1572 cases. The dose coefficients based on ICRP 107 increased by over 10 % compared with those based on ICRP 38 in 98 cases, and decreased by over 10 % in 54 cases. It was foundmore » that the differences in dose coefficients mainly originated from changes in the radiation energy emitted per nuclear transformation. In addition, revisions of the half-lives, radiation types and decay modes also resulted in changes in the dose coefficients.« less
Risk of eye lens radiation exposure for members of the public.
Chevallier, M-A; Rannou, A; Villagrasa, C; Clairand, I
2016-01-01
In 2011, the International Commission on Radiological Protection (ICRP) reviewed its recommendation concerning the equivalent dose limit for the eye lens, lowering it to 20 mSv in a year, for occupational exposure in planned exposure situations. The ICRP's statement does not contain any explicit recommendations regarding the organ dose limit for the eye lens for public exposure. For the moment, no change is proposed. But, to be coherent in the overall approach, the current equivalent limit for the public might be lowered. A similar yardstick than in the former recommendation may be used, that is to say a reduction of 10 times lower than that for occupational exposure. In this context, additional data on potential scenarios for public exposure of the eye lens are necessary. This paper, mainly based on a literature study, aims to provide, as far as possible, an exhaustive list of the situations in which members of the public can be exposed at the level of the eye lens. Once these situations have been defined, some calculations, made to assess the associated doses to the eye lens, are presented. This literature study did not reveal any current situations where members of the public would receive significant radiation doses to the eye lens. Indeed, the situations in which the dose to the eye lens might reach around 1 mSv per year for the public are extremely rare. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
ERIC Educational Resources Information Center
Peck, Greg
This document contains (1) the final report of a project to develop a computer-aided drafting (CAD) curriculum and (2) a competency-based unit of instruction for use with the CADAPPLE system. The final report states the problem and project objective, presents conclusions and recommendations, and includes survey instruments. The unit is designed…
ICRP Publication 134: Occupational Intakes of Radionuclides: Part 2.
Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Ansoborlo, E; Giussani, A; Bolch, W E; Harrison, J D
2016-12-01
The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988b) and Publication 68 (ICRP, 1994b). In addition, new data are available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. Part 1 of the OIR series has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. The following publications in the OIR series (Parts 2–5) will provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv per Bq intake) for inhalation and ingestion, tables of committed effective dose per content (Sv per Bq measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of reports contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. The present publication provides the above data for the following elements: hydrogen (H), carbon (C), phosphorus (P), sulphur (S), calcium (Ca), iron (Fe), cobalt (Co), zinc (Zn), strontium (Sr), yttrium (Y), zirconium (Zr), niobium (Nb), molybdenum (Mo), and technetium (Tc).
EPA's Science Plan for Activities Related to Dioxins in the ...
The U.S. Environmental Protection Agency is currently addressing several issues related to dioxins and dioxin-like chemicals in the environment. These include the comprehensive human health and exposure assessment for dioxin, commonly called the dioxin reassessment and a review of dioxin soil clean-up levels currently in use across the United States. To move forward with both of these efforts, as well as other dioxin related activities, a plan with interim milestones has been developed and it is outlined below. EPA’sExposure and Human Health Reassessment of 2,3,7,8-Tetrachlorodibenzo-p-Dioxin(TCDD) and Related Compounds; Response to NAS and Completion of Dioxin Reassessment 1. EPA will release a draft report that responds to the recommendations and comments included in the National Academy of Sciences’ (NAS) 2006 review of EPA’s 2003 draft dioxin reassessment. UPDATED May 21, 2010: The draft response to comments report titled EPA’s Reanalysis of Key Issues Related to Dioxin Toxicity and Response to NAS Comments (External Review Draft) (“Draft Dioxin Reanalysis”) was completed and released for public review and comment on May 21, 2010. EPA’s National Center for Environment Assessment (NCEA) in the Office of Research and Development, will prepare a limited response to key comments and recommendations in the NAS report (draft response to comments report). The draft response will focus on dose-response
Kramer, R; Khoury, H J; Vieira, J W; Loureiro, E C M; Lima, V J M; Lima, F R A; Hoff, G
2004-12-07
The International Commission on Radiological Protection (ICRP) has created a task group on dose calculations, which, among other objectives, should replace the currently used mathematical MIRD phantoms by voxel phantoms. Voxel phantoms are based on digital images recorded from scanning of real persons by computed tomography or magnetic resonance imaging (MRI). Compared to the mathematical MIRD phantoms, voxel phantoms are true to the natural representations of a human body. Connected to a radiation transport code, voxel phantoms serve as virtual humans for which equivalent dose to organs and tissues from exposure to ionizing radiation can be calculated. The principal database for the construction of the FAX (Female Adult voXel) phantom consisted of 151 CT images recorded from scanning of trunk and head of a female patient, whose body weight and height were close to the corresponding data recommended by the ICRP in Publication 89. All 22 organs and tissues at risk, except for the red bone marrow and the osteogenic cells on the endosteal surface of bone ('bone surface'), have been segmented manually with a technique recently developed at the Departamento de Energia Nuclear of the UFPE in Recife, Brazil. After segmentation the volumes of the organs and tissues have been adjusted to agree with the organ and tissue masses recommended by ICRP for the Reference Adult Female in Publication 89. Comparisons have been made with the organ and tissue masses of the mathematical EVA phantom, as well as with the corresponding data for other female voxel phantoms. The three-dimensional matrix of the segmented images has eventually been connected to the EGS4 Monte Carlo code. Effective dose conversion coefficients have been calculated for exposures to photons, and compared to data determined for the mathematical MIRD-type phantoms, as well as for other voxel phantoms.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
... such as Internet promotion, social media, emails, CD-ROMs, and DVDs. Following issuance of the guidance... materials. The recommendations in the draft guidance pertain to product names in traditional print media...
1981-04-01
east of Arcola Creek. The Interim Report gave a favorable recommendation for the harbor project and the results were published in House Document No. 91...Draft Reformulation Phase I GDM Re]port (Draft Stage 3 Report) The purpi se of this )rf t Stag. 3 Report Is to present the results of the Stage 3...Iirements for a small-boat harbor at Geneva State Park. Results of the bathymetric survey and sediment sampling program are presented in Appendix A. (3
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-18
...The Food and Drug Administration (FDA) is announcing the availability of a draft guidance for industry entitled ``Patient Counseling Information Section of Labeling for Human Prescription Drug and Biological Products--Content and Format.'' The recommendations in the draft guidance are intended to help ensure that the labeling is clear, useful, informative, and to the extent possible, consistent in content and format.
The purpose of this draft report is to provide a summary of climate change impacts to selected watersheds and recommendations for how to improve the process of conducting watershed assessments in the future.
The optimisation of occupational potential exposures - preliminary considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crouail, P.; Guimaraes, L.
1995-03-01
One of the major innovation brought about the ICRP 60 recommendations and emphasized by the ICRP 64 publication, is the introduction of the concept of potential exposures into the system of radiological protection. Potential exposures are characterized by {open_quotes}probability of occurrence lesser than unity{close_quotes} and {open_quotes}radiological risks exceeding normal levels{close_quotes} where normal must be interpreted as not exceeding the planned routine exposures. It is then necessary to develop consensual methods to look for and choose the optimum scenarios (i.e. those for which probability of events and possible consequences have been reduced as low as reasonably achievable). Moreover, the boundaries formore » the unacceptable levels of risks for workers should be defined, as well as reasonable risk indicators. The aim of this paper is to discuss the actual changes in the field of occupational radiological protection, induced by the potential exposure concept with particular emphasize on the optimization of protection.« less
Conversion of ICRP male reference phantom to polygon-surface phantom
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi
2013-10-01
The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as photons and neutrons. The results of the electron beams, on the other hand, show that the dose values of the polygon-surface phantom are higher by a factor of 2-5 times than those of the ICRP reference phantom for the skin and wall organs which have large holes due to low voxel resolution. The results demonstrate that the ICRP reference phantom could provide significantly unreasonable dose values to thin or wall organs especially for weakly penetrating radiations. Therefore, when compared to the original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating radiations such as electrons and other charged particles.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-19
... Committee Healthcare Personnel Influenza Vaccination Subgroup's Draft Report and Draft Recommendations for Achieving the Healthy People 2020 Annual Coverage Goals for Influenza Vaccination in Healthcare Personnel... Influenza Vaccination Subgroup (HCPIVS), will host an informational webinar to introduce the committee's...
Telescience Testbed Pilot Program
NASA Technical Reports Server (NTRS)
Gallagher, Maria L. (Editor); Leiner, Barry M. (Editor)
1988-01-01
The Telescience Testbed Pilot Program is developing initial recommendations for requirements and design approaches for the information systems of the Space Station era. During this quarter, drafting of the final reports of the various participants was initiated. Several drafts are included in this report as the University technical reports.
NASA Astrophysics Data System (ADS)
Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun
2017-03-01
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Mindell, J; Sheridan, L; Joffe, M; Samson-Barry, H; Atkinson, S
2004-03-01
To increase the positive and mitigate the negative health impacts of the mayor's draft transport strategy for London. A rapid prospective health impact assessment (HIA) of the penultimate draft of the strategy, using a review commissioned by the regional director of public health; an appraisal of congestion charging; and a participatory workshop. Two audits of changes were performed to assess the impact on policy of the HIA process. Regional government policy development. Recommendations from the rapid HIA were fed back into the drafting process. Changes (a) between the penultimate draft and the draft for public consultation and (b) between that and the final mayoral strategy. The draft transport strategy published for consultation differed in a number of respects from the previous version. Almost all the recommendations from the HIA were incorporated into the final strategy. Significant changes included promoting sustainable travel plans for workplaces and schools; giving priority to infrastructure and services that benefit London's deprived communities; increased emphasis on promoting walking and cycling and reducing reliance on private cars; and a commitment to track the health impacts of the final strategy and its implementation. Specific additions included re-allocating road space. HIA was successful in influencing the transport strategy for London, resulting in several improvements from a health viewpoint. HIA is an effective method both for bringing about significant change in policy proposals and in increasing policy makers' understanding of determinants of health and hence in changing attitudes of policy makers.
Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W
2012-04-01
To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Measurement of dose equivalent distribution on-board commercial jet aircraft.
Kubančák, J; Ambrožová, I; Ploc, O; Pachnerová Brabcová, K; Štěpán, V; Uchihori, Y
2014-12-01
The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21: (1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36: , 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108: (2), 91-105 (2004)], the ambient dose equivalent rate Ḣ*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate Ḣ*(10) on-board selected types of aircraft. The authors found that Ḣ*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ethos in Fukushima and the ICRP dialogue seminars.
Ando, R
2016-12-01
Ethos in Fukushima, a non-profit organisation, participated in 10 of the 12 International Commission on Radiological Protection (ICRP) dialogue seminars over the past 4 years. The slides and videos that were shown at the seminars are recorded on the Ethos in Fukushima website ( http://ethos-fukushima.blogspot.jp/p/icrp-dialogue.html ). I would like to introduce the activities of Ethos in Fukushima to date, and explain why the ICRP dialogue materials have come to be published on its website.
Mundt, Kenneth A; Gentry, P Robinan; Dell, Linda D; Rodricks, Joseph V; Boffetta, Paolo
2018-02-01
Shortly after the International Agency for Research on Cancer (IARC) determined that formaldehyde causes leukemia, the United States Environmental Protection Agency (EPA) released its Draft IRIS Toxicological Review of Formaldehyde ("Draft IRIS Assessment"), also concluding that formaldehyde causes leukemia. Peer review of the Draft IRIS Assessment by a National Academy of Science committee noted that "causal determinations are not supported by the narrative provided in the draft" (NRC 2011). They offered recommendations for improving the Draft IRIS assessment and identified several important research gaps. Over the six years since the NRC peer review, significant new science has been published. We identify and summarize key recommendations made by NRC and map them to this new science, including extended analysis of epidemiological studies, updates of earlier occupational cohort studies, toxicological experiments using a sensitive mouse strain, mechanistic studies examining the role of exogenous versus endogenous formaldehyde in bone marrow, and several critical reviews. With few exceptions, new findings are consistently negative, and integration of all available evidence challenges the earlier conclusions that formaldehyde causes leukemia. Given formaldehyde's commercial importance, environmental ubiquity and endogenous production, accurate hazard classification and risk evaluation of whether exposure to formaldehyde from occupational, residential and consumer products causes leukemia are critical. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
This document describes the updated draft testing protocol recommended by the EPA to support the registration of copper-containing surface products (such as door knobs, or other items that are not intended for food contact) that bear sanitizer claims.
EPA's recently published draft Risk Burn Guidance recommends that hazardous waste combustion facilities complete a mass balance of the total organics (TOs) that may be emitted from the combustor. TOs, consisting of three distinct fractions (volatile, semivolatile, and nonvolatile...
The paper discusses measurement issues relating to the characterization of organic emissions from hazardous waste incineration processes under EPA's new risk burn guidance. The recently published draft quidance recommends that hazardous waste combustion facilities complete a mass...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
...] Draft Guidance for Industry and FDA Staff: Processing/ Reprocessing Medical Devices in Health Care... Devices in Health Care Settings: Validation Methods and Labeling.'' The recommendations in this guidance... Staff: Processing/Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-12
... Products (VICH). This draft VICH guidance document is intended to provide study design recommendations... Products; Draft Guidance for Industry on Studies to Evaluate the Metabolism and Residue Kinetics of Veterinary Drugs in Food-Producing Animals: Marker Residue Depletion Studies to Establish Product Withdrawal...
Quadrennial Review of Military Compensation (7TH). Global Subject Papers
1992-08-01
the added result of reducing officers’ retired pay via a reduction in Basic Pay. The draft report recommends the continuous payment of BAS to all...being eligible for VHA is unfair. However, we also believe a minimum eligibility period is needed. The draft report recommends payment of full housing...93-12040 JOIN form Approved REPORT DOCUMENTATION PACE J No0 *flcrr t 0 datA .,-Vtr A’d :,r.¶tq. ~.-- r’ ~ (F. 0 ’ ~ ~ t’-e’,’ -o..t,7d’ A-t’trt I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, C; Dave, J
Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROImore » sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
... Polysulfate Sodium Capsule; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY... entitled ``Bioequivalence Recommendations for Pentosan Polysulfate Sodium.'' The recommendations provide... (ANDAs) for pentosan polysulfate sodium capsule. DATES: Although you can comment on any guidance at any...
Estimation of eye lens doses received by pediatric interventional cardiologists.
Alejo, L; Koren, C; Ferrer, C; Corredoira, E; Serrada, A
2015-09-01
Maximum Hp(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP. Copyright © 2015 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-11
....html . Fax: 907-474-2282. Mail: Eastern Interior Field Office, Attention--Eastern Interior Draft RMP... opening about 44 percent of the NRA to hardrock mineral leasing. This decision was never implemented. The... Alternative D to include hardrock mineral leasing. This alternative would recommend making approximately 160...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
...] Draft Guidance for Industry on Size, Shape, and Other Physical Attributes of Generic Tablets and... ``Size, Shape, and Other Physical Attributes of Generic Tablets and Capsules.'' This guidance discusses FDA recommendations for the size, shape, and other physical attributes of generic tablets intended to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-05
...The Food and Drug Administration (FDA) is announcing the availability of a draft document entitled ``Guidance for Industry: Use of Donor Screening Tests to Test Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) for Infection with Treponema pallidum (Syphilis),'' dated October 2013. The draft guidance document provides establishments that make donor eligibility determinations for donors of HCT/Ps (HCT/P Establishments), with updated recommendations concerning donor testing for evidence of Treponema pallidum (T. pallidum) infection, the etiologic agent of syphilis. HCT/P Establishments must, as required under Federal regulations, test a donor specimen for evidence of T. pallidum infection using appropriate FDA-licensed, approved, or cleared donor screening tests, in accordance with the manufacturer's instructions, unless an exception to this requirement applies. The draft guidance clarifies that FDA does not consider diagnostic tests or pre-amendment devices (which have not been licensed, approved, or cleared) to be adequate for use in donor testing for T. pallidum infection under the criteria specified in Federal regulations. The recommendations in this guidance, when finalized, will supersede those recommendations for testing HCT/P donors for evidence of T. pallidum infection contained in the document entitled ``Guidance for Industry: Eligibility Determination for Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps),'' dated August 2007.
Comparison of fluence-to-dose conversion coefficients for deuterons, tritons and helions.
Copeland, Kyle; Friedberg, Wallace; Sato, Tatsuhiko; Niita, Koji
2012-02-01
Secondary radiation in aircraft and spacecraft includes deuterons, tritons and helions. Two sets of fluence-to-effective dose conversion coefficients for isotropic exposure to these particles were compared: one used the particle and heavy ion transport code system (PHITS) radiation transport code coupled with the International Commission on Radiological Protection (ICRP) reference phantoms (PHITS-ICRP) and the other the Monte Carlo N-Particle eXtended (MCNPX) radiation transport code coupled with modified BodyBuilder™ phantoms (MCNPX-BB). Also, two sets of fluence-to-effective dose equivalent conversion coefficients calculated using the PHITS-ICRP combination were compared: one used quality factors based on linear energy transfer; the other used quality factors based on lineal energy (y). Finally, PHITS-ICRP effective dose coefficients were compared with PHITS-ICRP effective dose equivalent coefficients. The PHITS-ICRP and MCNPX-BB effective dose coefficients were similar, except at high energies, where MCNPX-BB coefficients were higher. For helions, at most energies effective dose coefficients were much greater than effective dose equivalent coefficients. For deuterons and tritons, coefficients were similar when their radiation weighting factor was set to 2.
The role of the ICRP in radiation protection--a view from industry.
Henrichs, K
2003-01-01
It is the objective of this paper to discuss some aspects concerning the role and importance of the ICRP. Here, this is done with a background of practical radiation protection in industry. The author organises and controls radiation protection for a worldwide operating company, for which efficiently realised radiation safety is as relevant for its workplaces as for its products and services. According to the author's subjective observation, the ICRP has a decreasing importance in operational radiation protection. However, there are growing demands on the ICRP as it is the only basis for internationally compatible regulations and standards. It is the merit of the ICRP that an international comparison of legal protection systems and concepts should give a much more homogeneous picture than that for any other safety and protection issue. The most valuable asset of the ICRP is its credibility as a scientific authority solely committed to the effective protection of people. But its success also brings with it an obligation: there is an increasing need for more effective communication to non-experts. This and other expectations for the future are briefly discussed.
Child Development and Social Studies Curriculum Design: Toward a Rationale.
ERIC Educational Resources Information Center
Knox, Gary A.
This paper is a working draft of a study which has examined the accumulated research on child growth and development. The draft is designed as an input paper to enable the Marin Social Studies Project to refine its rationale and criteria for a recommended K-12 social studies program of curriculum options. Identification of the capabilities of…
ERIC Educational Resources Information Center
Pollard, Jim
This report reviews eight IBM-compatible software packages that are available to secondary schools to teach computer-aided drafting (CAD). Software packages to be considered were selected following reviews of CAD periodicals, computers in education periodicals, advertisements, and recommendations of teachers. The packages were then rated by…
ERIC Educational Resources Information Center
Pollard, Jim
This report reviews software packages for Apple Macintosh and Apple II computers available to secondary schools to teach computer-aided drafting (CAD). Products for the report were gathered through reviews of CAD periodicals, computers in education periodicals, advertisements, and teacher recommendations. The first section lists the primary…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
... inspection by FDA during the review of marketing applications. This draft guidance describes a recommended... associated with marketing applications. The summary level clinical site dataset: Contains data from all... represent the Agency's current thinking on this topic. It does not create or confer any rights for or on any...
Construction of new skin models and calculation of skin dose coefficients for electron exposures
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Kim, Chan Hyeong; Nguyen, Thang Tat; Choi, Chansoo; Han, Min Cheol; Jeong, Jong Hwi
2016-08-01
The voxel-type reference phantoms of the International Commission on Radiological Protection (ICRP), due to their limited voxel resolutions, cannot represent the 50- μm-thick radiosensitive target layer of the skin necessary for skin dose calculations. Alternatively, in ICRP Publication 116, the dose coefficients (DCs) for the skin were calculated approximately, averaging absorbed dose over the entire skin depth of the ICRP phantoms. This approximation is valid for highly-penetrating radiations such as photons and neutrons, but not for weakly penetrating radiations like electrons due to the high gradient in the dose distribution in the skin. To address the limitation, the present study introduces skin polygon-mesh (PM) models, which have been produced by converting the skin models of the ICRP voxel phantoms to a high-quality PM format and adding a 50- μm-thick radiosensitive target layer into the skin models. Then, the constructed skin PM models were implemented in the Geant4 Monte Carlo code to calculate the skin DCs for external exposures of electrons. The calculated values were then compared with the skin DCs of the ICRP Publication 116. The results of the present study show that for high-energy electrons (≥ 1 MeV), the ICRP-116 skin DCs are, indeed, in good agreement with the skin DCs calculated in the present study. For low-energy electrons (< 1 MeV), however, significant discrepancies were observed, and the ICRP-116 skin DCs underestimated the skin dose as much as 15 times for some energies. Besides, regardless of the small tissue weighting factor of the skin ( w T = 0.01), the discrepancies in the skin dose were found to result in significant discrepancies in the effective dose, demonstarting that the effective DCs in ICRP-116 are not reliable for external exposure to electrons.
NASA Astrophysics Data System (ADS)
Bundke, U.; Hänel, G.
2003-04-01
During the LACE 98footnote{Lindenberg Aerosol Characterization Experiment, (Germany) 1998} experiment microphysical, chemical and optical properties of atmospheric particles were measured by several groups. (Bundke et al.). The particle deposition and clearance of the particles in the human respiratory tract was calculated using the ICRP (International Commission on Radiological Protection) deposition and clearance model (ICRP 1994). Particle growth as function of relative humidity outside the body was calculated from measurement data using the model introduced by Bundke et al.. Particle growth inside the body was added using a non-equilibrium particle growth model. As a result of the calculations, time series of the total dry particle mass and -size distribution were obtained for all compartments of the human respiratory tract defined by ICRP 1994. The combined ICRP deposition and clearance model was initialized for different probationers like man, woman, children of different ages and several circumstances like light work, sitting, sleeping etc. Keeping the conditions observed during LACE 98 constant a approximation of the aerosol burdens of the different compartments was calculated up to 4 years of exposure and compared to the results from Snipes et al. for the "Phoenix" and "Philadelphia" aerosol. References: footnotesize{ Bundke, U. et al.,it{Aerosol Optical Properties during the Lindenberg Aerosol Characterization Experiment (LACE 98)} ,10.1029/2000JD000188, JGR, 2002 ICRP,it{Human Respiratory Tract Model for Radiological Protection, Bd. ICRP Publication 66}, Annals of the ICRP, 24,1-3, Elsevier Science, Ocford, 1994 Snipes et al. ,it{The 1994 ICRP66 Human Respiratory Tract Model as a Tool for predicting Lung Burdens from Exposure to Environmental Aerosols}, Appl. Occup. Environ. Hyg., 12, 547-553,1997}
Response Funtions for Computing Absorbed Dose to Skeletal Tissues from Photon Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerman, Keith F; Bolch, W E; Zankl, M
2007-01-01
The calculation of absorbed dose in skeletal tissues at radiogenic risk has been a difficult problem because the relevant structures cannot be represented in conventional geometric terms nor can they be visualised in the tomographic image data used to define the computational models of the human body. The active marrow, the tissue of concern in leukaemia induction, is present within the spongiosa regions of trabecular bone, whereas the osteoprogenitor cells at risk for bone cancer induction are considered to be within the soft tissues adjacent to the mineral surfaces. The International Commission on Radiological Protection (ICRP) recommends averaging the absorbedmore » energy over the active marrow within the spongiosa and over the soft tissues within 10 mm of the mineral surface for leukaemia and bone cancer induction, respectively. In its forthcoming recommendation, it is expected that the latter guidance will be changed to include soft tissues within 50 mm of the mineral surfaces. To address the computational problems, the skeleton of the proposed ICRP reference computational phantom has been subdivided to identify those voxels associated with cortical shell, spongiosa and the medullary cavity of the long bones. It is further proposed that the Monte Carlo calculations with these phantoms compute the energy deposition in the skeletal target tissues as the product of the particle fluence in the skeletal subdivisions and applicable fluence-to-dose response functions. This paper outlines the development of such response functions for photons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerman, K.F.
Committee 2 of the International Commission on Radiological Protection (ICRP) has had efforts underway to provide the radiation protection community with age-dependent dose coefficients, i.e.g, the dose per unit intake. The Task Group on Dose Calculations, chaired by the author, is responsible for the computation of these coefficients. The Task Group, formed in 1974 to produce ICRP Publication 30, is now international in its membership and its work load has been distributed among the institutions represented on the task group. This paper discusses: (1) recent advances in biokinetic modeling; (2) the recent changes in the dosimetric methodology; (3) the novelmore » computational problems with some of the ICRP quantities; and (4) quality assurance issues which the Task Group has encountered. Potential future developments of the dosimetric framework which might strengthen the relationships with the emerging understanding of radiation risk will also be discussed.« less
Evaluation of the Inhalation Carcinogenicity of Ethylene Oxide ...
On September 22, 2006, the draft Evaluation of the Carinogenicity of Ethylene Oxide (EPA/635/R-06/003) and the draft charge to external peer reviewers were released for external peer review and public comment. This draft was reviewed by EPA’s Science Advisory Board (SAB) and the expert panel’s final report was made available December 21, 2007. Since that time the Agency implemented the May 2009 IRIS assessment development process in which other federal agencies and the Executive Offices of the President are provided two opportunities to comment on IRIS human health assessments; Interagency Science Consultation (Step 3) prior to public comment/peer review and Interagency Science Discussion (Step 6b) following peer review. In July, 2011, the draft assessment incorporating the SAB recommendations (December 2007) was sent to other federal agencies and Executive Offices of the President as part of Step 6 of the IRIS process. Following the May 2009 process, all written comments submitted by other agencies will be made publicly available. Accordingly, the interagency comments for ethylene oxide and the interagency science discussion materials provided to the other agencies are posted on this site. Note: After further consideration EPA has decided to undertake an additional peer review of the revised draft assessment on how the Agency responded to the SAB panel recommendations (December 2007), the exposure-response modeling of epidemiologic data, including n
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, Hsu-Chi; Phalen, R.F.; Chang, I.
1995-12-01
The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Althoughmore » this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny ({approximately} 1 nm) to particles larger than 100 {mu}m. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar.« less
ERIC Educational Resources Information Center
Labelle, Martin; Beaulieu, Michele; Renzi, Paolo; Rahme, Elham; Thivierge, Robert L.
2004-01-01
Introduction: Written action plans (WAPs) are instructions that enable asthmatics to manage their condition appropriately and are recommended by current asthma clinical practice guidelines (CPGs). However, general practitioners (GPs) rarely draft WAPs for their patients. An interactive, case-based workshop for asthma, combined with an objective…
McAlindon, T E; Driban, J B; Henrotin, Y; Hunter, D J; Jiang, G-L; Skou, S T; Wang, S; Schnitzer, T
2015-05-01
The goal of this document is to update the original OARSI recommendations specifically for the design, conduct, and reporting of clinical trials that target symptom or structure modification among individuals with knee osteoarthritis (OA). To develop recommendations for the design, conduct, and reporting of clinical trials for knee OA we initially drafted recommendations through an iterative process. Members of the working group included representatives from industry and academia. After the working group members reviewed a final draft, they scored the appropriateness for recommendations. After the members voted we calculated the median score among the nine members of the working group who completed the score. The document includes 25 recommendations regarding randomization, blocking and stratification, blinding, enhancing accuracy of patient-reported outcomes (PRO), selecting a study population and index knee, describing interventions, patient-reported and physical performance measures, structural outcome measures, biochemical biomarkers, and reporting recommendations. In summary, the working group identified 25 recommendations that represent the current best practices regarding clinical trials that target symptom or structure modification among individuals with knee OA. These updated recommendations incorporate novel technologies (e.g., magnetic resonance imaging (MRI)) and strategies to address the heterogeneity of knee OA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-15
...The Food and Drug Administration (FDA) is announcing the availability of a draft guidance entitled ``M7 Assessment and Control of DNA Reactive (Mutagenic) Impurities in Pharmaceuticals to Limit Potential Carcinogenic Risk.'' The draft guidance was prepared under the auspices of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The draft guidance emphasizes considerations of both safety and quality risk management in establishing levels of mutagenic impurities that are expected to pose negligible carcinogenic risk. It outlines recommendations for assessment and control of mutagenic impurities that reside or are reasonably expected to reside in a final drug substance or product, taking into consideration the intended conditions of human use. The draft guidance is intended to provide guidance for new drug substances and new drug products during their clinical development and subsequent applications for marketing.
Evolution of the Radiological Protection System and its Implementation.
Lazo, Edward
2016-02-01
The International System of Radiological Protection, developed, maintained, and elaborated by the International Commission on Radiological Protection (ICRP) has, for the past 50 y, provided a robust framework for developing radiological protection policy, regulation, and application. It has, however, been evolving as a result of experience with its implementation, modernization of social awareness of a shrinking world where the Internet links everyone instantly, and increasing public interest in safety-related decisions. These currents have gently pushed the ICRP in recent years to focus more sharply on particular aspects of its system: optimization, prevailing circumstances, the use of effective dose and aspects of an individual's risk, and consideration of the independent implementation of the international system's elements. This paper will present these issues and their relevance to the ICRP system of protection and its evolution. The broader framework of radiological protection (e.g., science, philosophy, policy, regulation, implementation), of which the ICRP is an important element, will provide a global, equally evolving context for this characterization of the changing ICRP system of radiological protection.
76 FR 48117 - Committee on Rulemaking
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-08
... States. The committee will meet to discuss a recommendation, concerning agency innovations in e... ``Conference Projects,'' and then on ``Agency Innovations in e-Rulemaking.'' Comments may be submitted by e... Rulemaking will meet to consider a draft recommendation concerning agency innovations in e- Rulemaking. The...
76 FR 58237 - Committee on Rulemaking
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... States. The committee will meet to discuss a recommendation concerning agency innovations in e-Rulemaking...'' -> ``Conference Projects'' -> ``Agency Innovations in e-Rulemaking.'' Comments may be submitted by e-mail to...: The Committee on Rulemaking will meet to consider a draft recommendation concerning agency innovations...
A review of lung-to-blood absorption rates for radon progeny.
Marsh, J W; Bailey, M R
2013-12-01
The International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model (HRTM) treats clearance of materials from the respiratory tract as a competitive process between absorption into blood and particle transport to the alimentary tract and lymphatics. The ICRP recommended default absorption rates for lead and polonium (Type M) in ICRP Publication 71 but stated that the values were not appropriate for short-lived radon progeny. This paper reviews and evaluates published data from volunteer and laboratory animal experiments to estimate the HRTM absorption parameter values for short-lived radon progeny. Animal studies showed that lead ions have two phases of absorption: ∼10 % absorbed with a half-time of ∼15 min, the rest with a half-time of ∼10 h. The studies also indicated that some of the lead ions were bound to respiratory tract components. Bound fractions, f(b), for lead were estimated from volunteer and animal studies and ranged from 0.2 to 0.8. Based on the evaluations of published data, the following HRTM absorption parameter values were derived for lead as a decay product of radon: f(r) = 0.1, s(r) = 100 d(-1), s(s) = 1.7 d(-1), f(b) = 0.5 and s(b) = 1.7 d(-1). Effective doses calculated assuming these absorption parameter values instead of a single absorption half-time of 10 h with no binding (as has generally been assumed) are only a few per cent higher. However, as there is some conflicting evidence on the absorption kinetics for radon progeny, dose calculations have been carried out for different sets of absorption parameter values derived from different studies. The results of these calculations are discussed.
O'Connor, U; Gallagher, A; Malone, L; O'Reilly, G
2013-02-01
Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures. A new eye lens dosemeter (EYE-D(™), Radcard, Krakow, Poland) was used to measure the ERCP eye dose, H(p)(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out. The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma area product is also presented. Staff eye doses in ERCP have the potential to exceed the revised ICRP limit of 20 mSv per annum when an overcouch X-ray tube is used. The EYE-D dosemeter was found to be a convenient method for measuring lens dose. Eye doses in areas outside of radiology departments should be kept under review, particularly in light of the new ICRP eye dose limit. Occupational eye lens doses from ERCP procedures have been established using a new commercially available dedicated H(p)(3) dosemeter.
Walsh, C; Gallagher, A; Dowling, A; Guiney, M; Ryan, J M; McEniff, N; O'Reilly, G
2015-01-01
Objective: In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Methods: Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Results: Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an “unprotected” eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma–area product and eye dose per procedure have been included in the analysis. Conclusion: Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. Advances in knowledge: We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting. PMID:25761211
Operational health physics training
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1992-06-01
The initial four sections treat basic information concerning atomic structure and other useful physical quantities, natural radioactivity, the properties of {alpha}, {beta}, {gamma}, x rays and neutrons, and the concepts and units of radiation dosimetry (including SI units). Section 5 deals with biological effects and the risks associated with radiation exposure. Background radiation and man-made sources are discussed next. The basic recommendations of the ICRP concerning dose limitations: justification, optimization (ALARA concepts and applications) and dose limits are covered in Section seven. Section eight is an expanded version of shielding, and the internal dosimetry discussion has been extensively revised tomore » reflect the concepts contained in the MIRD methodology and ICRP 30. The remaining sections discuss the operational health physics approach to monitoring radiation. Individual sections include radiation detection principles, instrument operation and counting statistics, health physics instruments and personnel monitoring devices. The last five sections deal with the nature of, operation principles of, health physics aspects of, and monitoring approaches to air sampling, reactors, nuclear safety, gloveboxes and hot cells, accelerators and x ray sources. Decontamination, waste disposal and transportation of radionuclides are added topics. Several appendices containing constants, symbols, selected mathematical topics, and the Chart of the Nuclides, and an index have been included.« less
Mairs, William DA
2016-06-01
The International Commission on Radiological Protection (ICRP) has recommended a 20 mSv year(-1) dose limit for the lens of the eye, which has been adopted in the European Union Basic Safety Standards. Interventional radiologists (IRs) and interventional cardiologists (ICs) are likely to be affected by this. The effects of radiation in the lens are somewhat uncertain, and the ICRP explicitly recommend optimization. Occupational dose constraints are part of the optimization process and define a level of dose which ought to be achievable in a well-managed practice. This commentary calls on the professional bodies to review a need for national constraints to guide local decisions. Consideration is given to developing such constraints using maximum expected doses in high-workload facilities with good radiation protection practices and application of a factor allowing for attenuation by lead glasses (LG). Doses are based on a Public Health England survey of eye dose in the UK. Maximum expected doses for ICs are approximately 21 mSv year(-1), neglecting LG. However, the extent of IR exposure is not yet fully known, and further evidence is required before conclusions are drawn. A Health and Safety Laboratory review of LG established a conservative dose reduction factor of 3 for models available in 2012. Application of this factor provides a dose constraint of 7 mSv year(-1) to the eye for ICs. To achieve this constraint, those employers with the most exposed ICs will have to provide and ensure the correct use of a ceiling-suspended eye shield and LG.
Predicted percentage dissatisfied with ankle draft.
Liu, S; Schiavon, S; Kabanshi, A; Nazaroff, W W
2017-07-01
Draft is unwanted local convective cooling. The draft risk model of Fanger et al. (Energy and Buildings 12, 21-39, 1988) estimates the percentage of people dissatisfied with air movement due to overcooling at the neck. There is no model for predicting draft at ankles, which is more relevant to stratified air distribution systems such as underfloor air distribution (UFAD) and displacement ventilation (DV). We developed a model for predicted percentage dissatisfied with ankle draft (PPD AD ) based on laboratory experiments with 110 college students. We assessed the effect on ankle draft of various combinations of air speed (nominal range: 0.1-0.6 m/s), temperature (nominal range: 16.5-22.5°C), turbulence intensity (at ankles), sex, and clothing insulation (<0.7 clo; lower legs uncovered and covered). The results show that whole-body thermal sensation and air speed at ankles are the dominant parameters affecting draft. The seated subjects accepted a vertical temperature difference of up to 8°C between ankles (0.1 m) and head (1.1 m) at neutral whole-body thermal sensation, 5°C more than the maximum difference recommended in existing standards. The developed ankle draft model can be implemented in thermal comfort and air diffuser testing standards. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Mattsson, S.; Johansson, L.; Leide-Svegborn, S.; Liniecki, J.; Nosske, D.; Riklund, K.; Stabin, M.; Taylor, D.
2011-09-01
A Task Group within the ICRP Committees 2 and 3 is continuously working to improve absorbed dose estimates to patients investigated with radiopharmaceuticals. The work deals with reviews of the literature, initiation of new or complementary studies of the biokinetics of a compound and dose estimates. Absorbed dose calculations for organs and tissues have up to now been carried out using the MIRD formalism. There is still a lack of necessary biokinetic data from measurements in humans. More time series obtained by nuclear medicine imaging techniques such as whole-body planar gamma-camera imaging, SPECT or PET are highly desirable for this purpose. In 2008, a new addendum to ICRP Publication 53 was published under the name of ICRP Publication 106 containing biokinetic data and absorbed dose information to organs and tissues of patients of various ages for radiopharmaceuticals in common use. That report also covers a number of generic models and realistic maximum models covering other large groups of substances (e.g. "123I-brain receptor substances"). Together with ICRP Publication 80, most radiopharmaceuticals in clinical use at the time of publication were covered except the radioiodine labeled compounds for which the ICRP dose estimates are still found in Publication 53. There is an increasing use of new radiopharmaceuticals, especially PET-tracers and the TG has recently finished its work with biokinetic and dosimetric data for 18F-FET, 18F-FLT and 18F-choline. The work continues now with new data for 11C-raclopride, 11C-PiB and 123I-ioflupan as well as re-evaluation of published data for 82Rb-chloride, 18F-fluoride and radioiodide. This paper summarises published ICRP-information on dose to patients from radiopharmaceuticals and gives some preliminary data for substances under review.
Development of skeletal system for mesh-type ICRP reference adult phantoms
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Wang, Zhao Jun; Tat Nguyen, Thang; Kim, Han Sung; Choi, Chansoo; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Chung, Beom Sun; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik
2016-10-01
The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (⩽4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to ~1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.
Calculation of local skin doses with ICRP adult mesh-type reference computational phantoms
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Han, Haegin; Choi, Chansoo; Nguyen, Thang Tat; Lee, Hanjin; Shin, Bangho; Kim, Chan Hyeong; Han, Min Cheol
2018-01-01
Recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) developed new mesh-type reference computational phantoms (MRCPs) for adult males and females in order to address the limitations of the current voxel-type reference phantoms described in ICRP Publication 110 due to their limited voxel resolutions and the nature of the voxel geometry. One of the substantial advantages of the MRCPs over the ICRP-110 reference phantoms is the inclusion of a 50-μm-thick radiosensitive skin basal-cell layer; however, a methodology for calculating the local skin dose (LSD), i.e., the maximum dose to the basal layer averaged over a 1-cm2 area, has yet to be developed. In the present study, a dedicated program for the LSD calculation with the MRCPs was developed based on the mean shift algorithm and the Geant4 Monte Carlo code. The developed program was used to calculate local skin dose coefficients (LSDCs) for electrons and alpha particles, which were then compared with the values given in ICRP Publication 116 that were produced with a simple tissue-equivalent cube model. The results of the present study show that the LSDCs of the MRCPs are generally in good agreement with the ICRP-116 values for alpha particles, but for electrons, significant differences are found at energies higher than 0.15 MeV. The LSDCs of the MRCPs are greater than the ICRP-116 values by as much as 2.7 times at 10 MeV, which is due mainly to the different curvature between realistic MRCPs ( i.e., curved) and the simple cube model ( i.e., flat).
18 CFR 5.19 - Tendering notice and schedule.
Code of Federal Regulations, 2011 CFR
2011-04-01
... environmental analysis notice provided for in § 5.22. (2) Filing of recommendations, preliminary terms and... recommendations, mandatory terms and conditions, and fishway prescriptions in response to a draft NEPA document or... issue an order resolving any requests for additional information-gathering or studies made in comments...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meinhold, C.B.
1982-01-01
This paper discusses the goals of the ICRP for the 1980 decade in optimizing radiation protection in the areas of workers, patients, and the public. Economic and operational concerns are expressed. (PSB)
Meeting Summary, Credit Trading Work Group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Bryan
2000-12-07
OAK-B135 Credit Trading Work Group Meeting Summary. The purpose of the meeting is to: (1) Provide an opportunity for NWCC Work Group Members, NWCC Members, and invited expert participants to hear an overview of the draft NWCC Credit Trading Report and to critically review and discuss the report's recommendations and principles. (2) Hear presentations from several perspectives of other experts on credit trading which provide: (a) a brief summary of credit trading activities they are involved in, and (b) critical responses to the NWCC draft report. (3) Identify how the report can be improved at the big picture level. Attemptmore » to resolve issues or concerns if necessary. (4) Discuss the recommendations and credit trading principles in detail and attempt to reach consensus on these sections for presentation to the NWCC. (5) Discuss if any of the outreach and communication recommendations in the report should be conducted by the NWCC.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-29
... Metronidazole Vaginal Gel; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The... entitled ``Bioequivalence Recommendations for Metronidazole Vaginal Gel.'' The guidance provides specific...) for metronidazole vaginal gel. DATES: Although you can comment on any guidance at any time (see 21 CFR...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-20
... Recommendations Prepared by the Research Committee of the Scientific Working Group on Medicolegal Death... Justice Programs, National Institute of Justice, Scientific Working Group for Medicolegal Death.../Medicolegal Death Investigation''. The opportunity to provide comments on this document is open to coroner...
75 FR 4416 - Policy on Cooperating Associations, Draft Director's Order #32
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-27
...) agreement. This policy will apply to all units of the national park system, and will replace the previous... reflect the findings and recommendations of the Cooperating Association Steering Committee submitted to the National Leadership Council in August 2009. These recommendations include as follows: The primary...
Calculation of the effective dose from natural radioactivity in soil using MCNP code.
Krstic, D; Nikezic, D
2010-01-01
Effective dose delivered by photon emitted from natural radioactivity in soil was calculated in this work. Calculations have been done for the most common natural radionuclides in soil (238)U, (232)Th series and (40)K. A ORNL human phantoms and the Monte Carlo transport code MCNP-4B were employed to calculate the energy deposited in all organs. The effective dose was calculated according to ICRP 74 recommendations. Conversion factors of effective dose per air kerma were determined. Results obtained here were compared with other authors. Copyright 2009 Elsevier Ltd. All rights reserved.
Kodak EDR2 film for patient skin dose assessment in cardiac catheterization procedures.
Morrell, R E; Rogers, A T
2006-07-01
Patient skin doses were measured using Kodak EDR2 film for 20 coronary angiography (CA) and 32 percutaneous transluminal coronary angioplasty (PTCA) procedures. For CA, all skin doses were well below 1 Gy. However, 23% of PTCA patients received skin doses of 1 Gy or more. Dose-area product (DAP) was also recorded and was found to be an inadequate indicator of maximum skin dose. Practical compliance with ICRP recommendations requires a robust method for skin dosimetry that is more accurate than DAP and is applicable over a wider dose range than EDR2 film.
Dose conversion factors for radon: recent developments.
Marsh, James W; Harrison, John D; Laurier, Dominique; Blanchardon, Eric; Paquet, François; Tirmarche, Margot
2010-10-01
Epidemiological studies of the occupational exposure of miners and domestic exposures of the public have provided strong and complementary evidence of the risks of lung cancer following inhalation of radon progeny. Recent miner epidemiological studies, which include low levels of exposure, long duration of follow-up, and good quality of individual exposure data, suggest higher risks of lung cancer per unit exposure than assumed previously by the International Commission on Radiological Protection (ICRP). Although risks can be managed by controlling exposures, dose estimates are required for the control of occupational exposures and are also useful for comparing sources of public exposure. Currently, ICRP calculates doses from radon and its progeny using dose conversion factors from exposure (WLM) to dose (mSv) based on miner epidemiological studies, referred to as the epidemiological approach. Revision of these dose conversion factors using risk estimates based on the most recent epidemiological data gives values that are in good agreement with the results of calculations using ICRP biokinetic and dosimetric models, the dosimetric approach. ICRP now proposes to treat radon progeny in the same way as other radionuclides and to publish dose coefficients calculated using models, for use within the ICRP system of protection.
Fell, T P
2007-01-01
The ICRP has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public including children and pregnant or lactating women. The calculation of these coefficients conveniently divides into two distinct parts--the biokinetic and dosimetric. This paper gives a brief summary of the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLaughlin, David A; Schwahn, Scott O
2011-01-01
While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 methodology is used, along with updated radiological decay data and metabolic data, to identify committed equivalent dose coefficients [hT(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory s Spallation Neutron Source.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-19
... Texts for Use in the International Conference on Harmonisation Regions; Annex 14 on Bacterial Endotoxins... ``Q4B Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions; Annex 14... Endotoxins Test General Chapter harmonized text from each of the three pharmacopoeias (United States...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [Docket Number... Recommendations for Application Authority: 30 U.S.C. 95l. AGENCY: National Institute for Occupational Safety and Health (NIOSH) of the Centers for Disease Control and Prevention (CDC), Department of Health and Human...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... issues implicated by agency use of social media to support rulemaking. The Conference's consultant for... Committee on Adjudication will meet to consider a draft report and recommendations on social security... and recommendations based on legal and empirical analysis of the Social Security Administration's...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-31
... intended for transfusion, including recommendations for validation and quality control monitoring of the..., including recommendations for validation and quality control monitoring of the leukocyte reduction process... control number 0910-0052; the collections of information in 21 CFR 606.100(b), 606.100(c), and 606.121...
NASA Astrophysics Data System (ADS)
Haltigin, T.; Lange, C.; Mugnuolo, R.; Smith, C.
2018-04-01
This paper summarizes the findings and recommendations of the International Mars Architecture for the Return of Samples (iMARS) Phase II Working Group, an international team comprising 38 members from 16 countries and agencies.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-31
... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1599] Increasing the Supply of Forensic Pathologists in the United States: A Report and Recommendations AGENCY: National... draft document entitled, ``Increasing the Supply of Forensic Pathologists in the United States: A Report...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-13
... Evaluation of Recommended Practice on Fatigue Risk Management Systems for Personnel in the Refining and... and Health Administration: 2001-05-I-DE-1 (Process Safety Management coverage of atmospheric storage tanks); 2005-04-I-TX-9 (Process Safety Management requirement for organizational management of change...
ASCCP Colposcopy Standards: Colposcopy Quality Improvement Recommendations for the United States.
Mayeaux, Edward J; Novetsky, Akiva P; Chelmow, David; Garcia, Francisco; Choma, Kim; Liu, Angela H; Papasozomenos, Theognosia; Einstein, Mark H; Massad, L Stewart; Wentzensen, Nicolas; Waxman, Alan G; Conageski, Christine; Khan, Michelle J; Huh, Warner K
2017-10-01
The American Society for Colposcopy and Cervical Pathology (ASCCP) Colposcopy Standards recommendations address the role of and approach to colposcopy and biopsy for cervical cancer prevention in the United States. The recommendations were developed by an expert working group appointed by ASCCP's Board of Directors. The ASCCP Quality Improvement Working Group developed evidence-based guidelines to promote best practices and reduce errors in colposcopy and recommended indicators to measure colposcopy quality. The working group performed a systematic review of existing major society and national guidelines and quality indicators. An initial list of potential quality indicators was developed and refined through successive iterative discussions, and draft quality indicators were proposed. The draft recommendations were then reviewed and commented on by the entire Colposcopy Standards Committee, posted online for public comment, and presented at the International Federation for Cervical Pathology and Colposcopy 2017 World Congress for further comment. All comments were considered, additional adjustments made, and the final recommendations approved by the entire Task Force. Eleven quality indicators were selected spanning documentation, biopsy protocols, and time intervals between index screening tests and completion of diagnostic evaluation. The proposed quality indicators are intended to serve as a starting point for quality improvement in colposcopy at a time when colposcopy volume is decreasing and individual procedures are becoming technically more difficult to perform.
76 FR 34073 - Sunshine Act Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... Meeting of May 26, 2011. Draft Notice of Proposed Rulemaking on Independent Expenditures and... Recommendation Memorandum on the United Association Political Education Committee (UAPEC) (A09-27). Future...
NASA Astrophysics Data System (ADS)
Jansen, Jan T. M.; Shrimpton, Paul C.
2016-07-01
The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of ±6% and ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10’s of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.
Overview of ICRP Committee 3: protection in medicine.
Vañó, E; Miller, D L; Rehani, M M
2016-06-01
Committee 3 of the International Commission on Radiological Protection (ICRP) develops recommendations and guidance for protection of patients, staff, and the public against radiation exposure when ionising radiation is used for medical diagnosis, therapy, or biomedical research. This paper presents a summary of the work that Committee 3 has accomplished over the past few years, and also describes its current work. The most recent reports published by the Commission that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (Publication 129), 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (Publication 128, in cooperation with Committee 2), 'Radiological protection in ion beam radiotherapy' (Publication 127), 'Radiological protection in paediatric diagnostic and interventional radiology' (Publication 121), 'Radiological protection in cardiology' (Publication 120), and 'Radiological protection in fluoroscopically guided procedures outside the imaging department' (Publication 117). A new report on diagnostic reference levels in medical imaging will provide specific advice for interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and hybrid (multi-modality) imaging procedures, and is expected to be published in 2016. Committee 3 is also working on guidance for occupational radiological protection in brachytherapy, and on guidance on occupational protection issues in interventional procedures, paying particular attention to the 2011 Commission's recommendations on the occupational dose limit for the lens of the eye (Publication 118). Other reports in preparation deal with justification, radiological protection in therapy with radiopharmaceuticals, radiological protection in medicine as related to individual radiosusceptibility, appropriate use of effective dose (in cooperation with other Committees), and guidance for healthcare practitioners on radiological and patient protection. Committee 3 has also suggested specific priorities for research on radiological protection in medicine to the Commission. © The International Society for Prosthetics and Orthotics.
Ainsbury, Elizabeth A; Barnard, Stephen; Bright, Scott; Dalke, Claudia; Jarrin, Miguel; Kunze, Sarah; Tanner, Rick; Dynlacht, Joseph R; Quinlan, Roy A; Graw, Jochen; Kadhim, Munira; Hamada, Nobuyuki
The lens of the eye has long been considered as a radiosensitive tissue, but recent research has suggested that the radiosensitivity is even greater than previously thought. The 2012 recommendation of the International Commission on Radiological Protection (ICRP) to substantially reduce the annual occupational equivalent dose limit for the ocular lens has now been adopted in the European Union and is under consideration around the rest of the world. However, ICRP clearly states that the recommendations are chiefly based on epidemiological evidence because there are a very small number of studies that provide explicit biological, mechanistic evidence at doses <2Gy. This paper aims to present a review of recently published information on the biological and mechanistic aspects of cataracts induced by exposure to ionizing radiation (IR). The data were compiled by assessing the pertinent literature in several distinct areas which contribute to the understanding of IR induced cataracts, information regarding lens biology and general processes of cataractogenesis. Results from cellular and tissue level studies and animal models, and relevant human studies, were examined. The main focus was the biological effects of low linear energy transfer IR, but dosimetry issues and a number of other confounding factors were also considered. The results of this review clearly highlight a number of gaps in current knowledge. Overall, while there have been a number of recent advances in understanding, it remains unknown exactly how IR exposure contributes to opacification. A fuller understanding of how exposure to relatively low doses of IR promotes induction and/or progression of IR-induced cataracts will have important implications for prevention and treatment of this disease, as well as for the field of radiation protection. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Effect of Dietary Intake of Stable Iodine on Dose-per-unit-intake Factors for 99Tc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strom, Daniel J.
It is well-known that the human thyroid concentrates iodine more than 100 times the concentration in plasma. Also well-known is the fact that large amounts of stable iodine in the diet can limit thyroid uptake of total iodine; this is the basis for administering potassium iodide following a release of radioiodine from a nuclear reactor accident or nuclear weapon detonation. Many researchers have shown enhanced concentrations of both organic and inorganic iodine in saliva and breast milk. Technetium-99 is a long-lived (231,000 year half-life) radionuclide of concern in the management of high-level radioactive waste. There is no doubt that 99Tc,more » if it is in groundwater, will be found in the chemical form of pertechnetate, 99TcO4?. Pertechnetate is a large anion, almost identical in size to iodide, I?. The nuclear medicine literature shows that pertechnetate concentrates in the thyroid, salivary glands, and lactating breast in addition to the stomach, liver, and alimentary tract as currently recognized by the International Commission on Radiological Protection (ICRP). The fact that large intakes of stable iodine (127I) in the diet limit uptake of iodine by the thyroid leads one to generalize that stable iodine in the diet may also limit thyroid uptake of pertechnetate. While there is at least one report that iodine in the diet blocks uptake of 99mTcO4? by the thyroid and salivary glands (which have the same Na/I symporter, the biochemical concentration mechanism), the level of protective effect seen for blocking radioactive iodine is not expected for 99TcO4? because pertechnetate does not become organically bound in the thyroid and thus is not retained for months the way iodide is. While it does account for Tc concentration in the thyroid, the existing ICRP biokinetic model for technetium does not take enhanced concentrations in salivary gland and breast tissue into account. From the survey of the nuclear medicine literature, it is not possible to compute the effect of stable iodine in the diet on the dose per unit intake factors for 99Tc without developing an improved biokinetic model for technetium. Specific experiments should be designed to quantitatively evaluate 99TcO4? metabolism, excretion, and secretion, as well as to evaluate its chemical toxicity It is recommended that the ICRP reexamine its biokinetics models for Tc based on nuclear medicine data that have accumulated over the years. In particular, the ICRP ignores the lactation pathway, the enhanced concentration of Tc in breast and breast milk, and enhanced concentration of Tc (and I) in the salivary glands as well as in the thyroid. The ICRP should also explicitly incorporate the effect of stable iodine in the diet into both its models for iodine and technetium. The effect of concentration of Tc in breast milk needs further study for dosimetric implications to nursing infants whose mothers may ingest 99TcO4? from groundwater sources. The ICRP should also investigate the possibility of enhanced concentration of both I and Tc in the non-lactating female breast. To do these re-evaluations of biokinetic models, new experiments designed specifically to evaluate these questions concerning the biokinetics of Tc and I are needed.« less
Age and gender specific biokinetic model for strontium in humans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shagina, N. B.; Tolstykh, E. I.; Degteva, M. O.
A biokinetic model for strontium in humans is necessary for quantification of internal doses due to strontium radioisotopes. The ICRP-recommended biokinetic model for strontium has limitation for use in a population study, because it is not gender specific and does not cover all age ranges. The extensive Techa River data set on 90Sr in humans (tens of thousands of measurements) is a unique source of data on long-term strontium retention for men and women of all ages at intake. These, as well as published data, were used for evaluation of age- and gender-specific parameters for a new compartment biokinetic modelmore » for strontium (Sr-AGe model). The Sr-AGe model has similar structure as the ICRP model for the alkaline earth elements. The following parameters were mainly reevaluated: gastro-intestinal absorption and parameters related to the processes of bone formation and resorption defining calcium and strontium transfers in skeletal compartments. The Sr-AGe model satisfactorily describes available data sets on strontium retention for different kinds of intake (dietary and intravenous) at different ages (0–80 years old) and demonstrates good agreement with data sets for different ethnic groups. The Sr-AGe model can be used for dose assessment in epidemiological studies of general population exposed to ingested strontium radioisotopes.« less
Estimates of internal-dose equivalent from inhalation and ingestion of selected radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dunning, D.E.
1982-01-01
This report presents internal radiation dose conversion factors for radionuclides of interest in environmental assessments of nuclear fuel cycles. This volume provides an updated summary of estimates of committed dose equivalent for radionuclides considered in three previous Oak Ridge National Laboratory (ORNL) reports. Intakes by inhalation and ingestion are considered. The International Commission on Radiological Protection (ICRP) Task Group Lung Model has been used to simulate the deposition and retention of particulate matter in the respiratory tract. Results corresponding to activity median aerodynamic diameters (AMAD) of 0.3, 1.0, and 5.0 ..mu..m are given. The gastorintestinal (GI) tract has been representedmore » by a four-segment catenary model with exponential transfer of radioactivity from one segment to the next. Retention of radionuclides in systemic organs is characterized by linear combinations of decaying exponential functions, recommended in ICRP Publication 30. The first-year annual dose rate, maximum annual dose rate, and fifty-year dose commitment per microcurie intake of each radionuclide is given for selected target organs and the effective dose equivalent. These estimates include contributions from specified source organs plus the systemic activity residing in the rest of the body; cross irradiation due to penetrating radiations has been incorporated into these estimates. 15 references.« less
Weighting factors for radiation quality: how to unite the two current concepts.
Kellerer, Albrecht M
2004-01-01
The quality factor, Q(L), used to be the universal weighting factor to account for radiation quality, until--in its 1991 Recommendations--the ICRP established a dichotomy between 'computable' and 'measurable' quantities. The new concept of the radiation weighting factor, w(R), was introduced for use with the 'computable' quantities, such as the effective dose, E. At the same time, the application of Q(L) was restricted to 'measurable' quantities, such as the operational quantities ambient dose equivalent or personal dose equivalent. The result has been a dual system of incoherent dosimetric quantities. The most conspicuous inconsistency resulted for neutrons, for which the new concept of wR had been primarily designed. While its definition requires an accounting for the gamma rays produced by neutron capture in the human body, this effect is not adequately reflected in the numerical values of wR, which are now suitable for mice, but are--at energies of the incident neutrons below 1 MeV--conspicuously too large for man. A recent Report 92 to ICRP has developed a proposal to correct the current imbalance and to define a linkage between the concepts Q(L) and wR. The proposal is here considered within a broader assessment of the rationale that led to the current dual system of dosimetric quantities.
Transportation of Hazardous Evidentiary Material.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osborn, Douglas.
2005-06-01
This document describes the specimen and transportation containers currently available for use with hazardous and infectious materials. A detailed comparison of advantages, disadvantages, and costs of the different technologies is included. Short- and long-term recommendations are also provided.3 DraftDraftDraftExecutive SummaryThe Federal Bureau of Investigation's Hazardous Materials Response Unit currently has hazardous material transport containers for shipping 1-quart paint cans and small amounts of contaminated forensic evidence, but the containers may not be able to maintain their integrity under accident conditions or for some types of hazardous materials. This report provides guidance and recommendations on the availability of packages for themore » safe and secure transport of evidence consisting of or contaminated with hazardous chemicals or infectious materials. Only non-bulk containers were considered because these are appropriate for transport on small aircraft. This report will addresses packaging and transportation concerns for Hazardous Classes 3, 4, 5, 6, 8, and 9 materials. If the evidence is known or suspected of belonging to one of these Hazardous Classes, it must be packaged in accordance with the provisions of 49 CFR Part 173. The anthrax scare of several years ago, and less well publicized incidents involving unknown and uncharacterized substances, has required that suspicious substances be sent to appropriate analytical laboratories for analysis and characterization. Transportation of potentially hazardous or infectious material to an appropriate analytical laboratory requires transport containers that maintain both the biological and chemical integrity of the substance in question. As a rule, only relatively small quantities will be available for analysis. Appropriate transportation packaging is needed that will maintain the integrity of the substance, will not allow biological alteration, will not react chemically with the substance being shipped, and will otherwise maintain it as nearly as possible in its original condition.The recommendations provided are short-term solutions to the problems of shipping evidence, and have considered only currently commercially available containers. These containers may not be appropriate for all cases. Design, testing, and certification of new transportation containers would be necessary to provide a container appropriate for all cases.Table 1 provides a summary of the recommendations for each class of hazardous material.Table 1: Summary of RecommendationsContainerCost1-quart paint can with ArmlockTM seal ringLabelMaster(r)%242.90 eachHazard Class 3, 4, 5, 8, or 9 Small ContainersTC Hazardous Material Transport ContainerCurrently in Use4 DraftDraftDraftTable 1: Summary of Recommendations (continued)ContainerCost55-gallon open or closed-head steel drumsAll-Pak, Inc.%2458.28 - %2473.62 eachHazard Class 3, 4, 5, 8, or 9 Large Containers95-gallon poly overpack LabelMaster(r)%24194.50 each1-liter glass container with plastic coatingLabelMaster(r)%243.35 - %243.70 eachHazard Class 6 Division 6.1 Poisonous by Inhalation (PIH) Small ContainersTC Hazardous Material Transport ContainerCurrently in Use20 to 55-gallon PIH overpacksLabelMaster(r)%24142.50 - %24170.50 eachHazard Class 6 Division 6.1 Poisonous by Inhalation (PIH) Large Containers65 to 95-gallon poly overpacksLabelMaster(r)%24163.30 - %24194.50 each1-liter transparent containerCurrently in UseHazard Class 6 Division 6.2 Infectious Material Small ContainersInfectious Substance ShipperSource Packaging of NE, Inc.%24336.00 eachNone Commercially AvailableN/AHazard Class 6 Division 6.2 Infectious Material Large ContainersNone Commercially Available N/A5« less
Comparative analysis of dosimetry parameters for nuclear medicine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toohey, R.E.; Stabin, M.G.
For years many have employed the concept of ``total-body dose`` or ``whole-body dose,`` i.e., the total energy deposited in the body divided by the mass of the body, when evaluating the risks of different nuclear medicine procedures. The effective dose equivalent (H{sub E}), first described in ICRP Publication 26, has been accepted by some as a better quantity to use in evaluating the total risk of a procedure, but its use has been criticized by others primarily because the tissue weighting factors were intended for use in the radiation worker, rather than the nuclear medicine patient population. Nevertheless, in ICRPmore » Publication 52, the ICRP has suggested that the H{sub E} may be used in nuclear medicine. The ICRP also has published a compendium of dose estimates, including H{sub E} values, for various nuclear medicine procedures at various ages in ICRP Publication 53. The effective dose (E) of ICRP Publication 60 is perhaps more suitable for use in nuclear medicine, with tissue weighting factors based on the entire population. Other comparisons of H{sub E} and E have been published. The authors have used the program MIRDOSE 3.1 to compute total-body dose, H{sub E}, and E for 62 radiopharmaceutical procedures, based on the best current biokinetic data available.« less
Report of Programme Commission II (Natural Sciences), Annex - Recommendations.
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Paris (France). General Conference.
As the second part of the report of the Programme Commission II, a summary of recommendations on plans for natural sciences and their applications is presented in this document. Resolutions and budgetary appropriations are two major concerns in the document. The topics are related to the 1973-74 draft program and budget, the 1973-78 draft…
The new World Organisation for Animal Health standards on avian influenza and international trade.
Thiermann, Alex B
2007-03-01
In 2002, the World Organisation for Animal Health began a review of the chapter on avian influenza by convening a group of experts to revise the most recent scientific literature. The group drafted the initial text that would provide the necessary recommendations on avian influenza control and prevention measures. The main objectives of this draft were to provide clear notification criteria, as well as commodity-specific, risk-based mitigating measures, that would provide safety when trading and encourage transparent reporting.
16 CFR 1203.3 - Referenced documents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... to the draft ISO standard. (2) SAE Recommended Practice SAE J211 OCT88, Instrumentation for Impact..., Instrumentation for Impact Tests, are available from Society of Automotive Engineers, 400 Commonwealth Dr...
16 CFR 1203.3 - Referenced documents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... to the draft ISO standard. (2) SAE Recommended Practice SAE J211 OCT88, Instrumentation for Impact..., Instrumentation for Impact Tests, are available from Society of Automotive Engineers, 400 Commonwealth Dr...
16 CFR 1203.3 - Referenced documents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... to the draft ISO standard. (2) SAE Recommended Practice SAE J211 OCT88, Instrumentation for Impact..., Instrumentation for Impact Tests, are available from Society of Automotive Engineers, 400 Commonwealth Dr...
[Radiation protection in interventional radiology].
Adamus, R; Loose, R; Wucherer, M; Uder, M; Galster, M
2016-03-01
The application of ionizing radiation in medicine seems to be a safe procedure for patients as well as for occupational exposition to personnel. The developments in interventional radiology with fluoroscopy and dose-intensive interventions require intensified radiation protection. It is recommended that all available tools should be used for this purpose. Besides the options for instruments, x‑ray protection at the intervention table must be intensively practiced with lead aprons and mounted lead glass. A special focus on eye protection to prevent cataracts is also recommended. The development of cataracts might no longer be deterministic, as confirmed by new data; therefore, the International Commission on Radiological Protection (ICRP) has lowered the threshold dose value for eyes from 150 mSv/year to 20 mSv/year. Measurements show that the new values can be achieved by applying all X‑ray protection measures plus lead-containing eyeglasses.
Lazo, T
2016-12-01
Between September 2011 and August 2015, the International Commission on Radiological Protection (ICRP) organised a series of 12 stakeholder dialogue workshops with residents of Fukushima Prefecture. Discussions focused on recovery, addressing topics such as protection of children, management of contaminated food, monitoring, and self-help measures. The OECD Nuclear Energy Agency (NEA) supported, and the Committee on Radiation Protection and Public Health (CRPPH) Secretariat attended, all 12 meetings to listen directly to the concerns of affected individuals and draw lessons for CRPPH. To summarise the dialogue results, ICRP organised a final meeting in Date, Japan with the support of NEA and other organisations. The lessons from and utility of the dialogue meetings were praised by dialogue participants and sponsors, and ICRP agreed that some form of dialogue would continue, although with ICRP participation and support rather than leadership. This paper summarises the internationally relevant lessons learned by CRPPH from this important process.
The 2009 schizophrenia PORT psychosocial treatment recommendations and summary statements.
Dixon, Lisa B; Dickerson, Faith; Bellack, Alan S; Bennett, Melanie; Dickinson, Dwight; Goldberg, Richard W; Lehman, Anthony; Tenhula, Wendy N; Calmes, Christine; Pasillas, Rebecca M; Peer, Jason; Kreyenbuhl, Julie
2010-01-01
The Schizophrenia Patient Outcomes Research Team (PORT) psychosocial treatment recommendations provide a comprehensive summary of current evidence-based psychosocial treatment interventions for persons with schizophrenia. There have been 2 previous sets of psychosocial treatment recommendations (Lehman AF, Steinwachs DM. Translating research into practice: the Schizophrenia Patient Outcomes Research Team (PORT) treatment recommendations. Schizophr Bull. 1998;24:1-10 and Lehman AF, Kreyenbuhl J, Buchanan RW, et al. The Schizophrenia Patient Outcomes Research Team (PORT): updated treatment recommendations 2003. Schizophr Bull. 2004;30:193-217). This article reports the third set of PORT recommendations that includes updated reviews in 7 areas as well as adding 5 new areas of review. Members of the psychosocial Evidence Review Group conducted reviews of the literature in each intervention area and drafted the recommendation or summary statement with supporting discussion. A Psychosocial Advisory Committee was consulted in all aspects of the review, and an expert panel commented on draft recommendations and summary statements. Our review process produced 8 treatment recommendations in the following areas: assertive community treatment, supported employment, cognitive behavioral therapy, family-based services, token economy, skills training, psychosocial interventions for alcohol and substance use disorders, and psychosocial interventions for weight management. Reviews of treatments focused on medication adherence, cognitive remediation, psychosocial treatments for recent onset schizophrenia, and peer support and peer-delivered services indicated that none of these treatment areas yet have enough evidence to merit a treatment recommendation, though each is an emerging area of interest. This update of PORT psychosocial treatment recommendations underscores both the expansion of knowledge regarding psychosocial treatments for persons with schizophrenia at the same time as the limitations in their implementation in clinical practice settings.
Tax-exempt hospitals and community benefits: a review of state reporting requirements.
Hellinger, Fred Joseph
2009-02-01
In June 2007 the Internal Revenue Service proposed a major overhaul of its reporting requirements for tax-exempt hospitals and released draft Form 990 (the IRS form filed by tax-exempt organizations each year). In December 2007 the IRS promulgated the final Form 990 after incorporating some of the recommendations made in the almost seven hundred public comments on the discussion draft. One recommendation adopted in the final Form 990 is the postponement until tax year 2009 (returns filed in 2010) of the requirement for hospitals to submit detailed information on the percentage of total expenses attributable to charity care, unreimbursed Medicaid costs, and community-health improvement programs (the discussion draft required this information for tax year 2007). Although the IRS will not require tax-exempt hospitals to provide detailed information about community benefits until the 2009 tax year, sixteen states have laws requiring tax-exempt hospitals to enumerate the benefits that they provide to the community. Information about the impact of these laws on the provision of community benefits (e.g., charity and uncompensated care) is examined in this study whose primary purpose is to highlight information policy makers may glean from states that have adopted community-benefit reporting laws.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-14
... Texts for Use in the International Conference on Harmonisation Regions; Annex 13 on Bulk Density and... guidance entitled ``Q4B Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions... evaluation of the Bulk Density and Tapped Density of Powders General Chapter harmonized text from each of the...
ERIC Educational Resources Information Center
UNESCO-UNEVOC International Centre for Technical and Vocational Education and Training, 2014
2014-01-01
This virtual conference is part of a larger consultation process through which UNESCO will consult with practitioners and researchers; representatives of key stakeholder groupings such as employers' federations, trade unions and youth organizations; other international agencies and Member States in order to draft a new Revised Recommendation that…
Fiscal Analysis of the Report of the Select Panel on Revisioning Education in Maine
ERIC Educational Resources Information Center
Silvernail, David L.; Batista, Ida A.
2006-01-01
In late 2005 the Select Panel on Revisioning Education in Maine issued their draft report describing a series of recommendations for the improvement of student learning in Maine. The Panel, convened by the Maine State Board of Education, and pursuant to Tile 20-A statutory requirements, developed their recommendations through six months of data…
Kersting, Sabina; Neppelenbroek, Suzanne I M; Visser, Hein P J; van Gelder, Michel; Levin, Mark-David; Mous, Rogier; Posthuma, Ward; van der Straaten, Hanneke M; Kater, Arnon P
2018-01-01
In recent years, considerable progress has been made in the treatment of patients with chronic lymphocytic leukemia (CLL), and new potent drugs have become available. Therefore, the CLL working party revised the Dutch guidelines. Not only efficacy but also quality of life and socio-economic impact were taken into account in the formulation of treatment recommendations. The working party discussed a set of questions regarding diagnostic tests and treatment and wrote the draft guideline. This was evidence-based whenever possible, but in cases of low evidence, an expert-based recommendation was formulated with input of the entire working party. The draft guideline was sent to all hematologists in the Netherlands for comment and was subsequently approved. Recommendations were formulated on diagnostic tests and work-up before treatment. Also, recommendations were made for treatment with fludarabine-cyclophosphamide-rituximab, bendamustine-rituximab, chlorambucil with anti-CD20 antibody, ibrutinib, idelalisib-rituximab, venetoclax, and allogeneic stem cell transplantation. In the revised Dutch CLL guidelines, chemo-immunotherapy is still the cornerstone of CLL treatment with novel targeted drugs for specific risk groups. Copyright © 2017 Elsevier Inc. All rights reserved.
Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.
Ludlow, J B; Davies-Ludlow, L E; Brooks, S L; Howerton, W B
2006-07-01
Cone beam computed tomography (CBCT), which provides a lower dose, lower cost alternative to conventional CT, is being used with increasing frequency in the practice of oral and maxillofacial radiology. This study provides comparative measurements of effective dose for three commercially available, large (12'') field-of-view (FOV), CBCT units: CB Mercuray, NewTom 3G and i-CAT. Thermoluminescent dosemeters (TLDs) were placed at 24 sites throughout the layers of the head and neck of a tissue-equivalent human skull RANDO phantom. Depending on availability, the 12'' FOV and smaller FOV scanning modes were used with similar phantom positioning geometry for each CBCT unit. Radiation weighted doses to individual organs were summed using 1990 (E(1990)) and proposed 2005 (E(2005 draft)) ICRP tissue weighting factors to calculate two measures of whole-body effective dose. Dose as a multiple of a representative panoramic radiography dose was also calculated. For repeated runs dosimetry was generally reproducible within 2.5%. Calculated doses in microSv [corrected] (E(1990), E(2005 draft)) were NewTom3G (45, 59), i-CAT (135, 193) and CB Mercuray (477, 558). These are 4 to 42 times greater than comparable panoramic examination doses (6.3 microSv [corrected] 13.3 mSv). Reductions in dose were seen with reduction in field size and mA and kV technique factors. CBCT dose varies substantially depending on the device, FOV and selected technique factors. Effective dose detriment is several to many times higher than conventional panoramic imaging and an order of magnitude or more less than reported doses for conventional CT.
Menopausal hormone therapy for primary prevention: why the USPSTF is wrong.
Langer, R D; Simon, J A; Pines, A; Lobo, R A; Hodis, H N; Pickar, J H; Archer, D F; Sarrel, P M; Utian, W H
2017-10-01
The US Preventive Services Task Force (USPSTF) Draft Recommendation statement on Menopausal Hormone Therapy: Primary Prevention for Chronic Diseases, released in May 2017, perpetuates a major disconnect between the primary population affected, women within roughly 10 years of menopause, and the data cited. Furthermore, major elements of the evidence relied upon have been misinterpreted or misstated, particularly in regard to coronary heart disease and breast cancer, for which there is no statistically significant evidence of harm. As currently drafted, the recommendations reiterate the USPSTF statements of 2012, 2005 and 2002, and will perpetuate egregious harm to the public health. In an attempt to avoid that outcome and to facilitate a return to rational discourse regarding menopausal hormone therapy, an ad hoc group of experts in menopausal health submitted this comprehensive response to the USPSTF.
Tamura, Taro; Suganuma, Narufumi; Hering, Kurt G; Vehmas, Tapio; Itoh, Harumi; Akira, Masanori; Takashima, Yoshihiro; Hirano, Harukazu; Kusaka, Yukinori
2015-01-01
The International Classification of High-resolution Computed Tomography (HRCT) for Occupational and Environmental Respiratory Diseases (ICOERD) has been developed for the screening, diagnosis, and epidemiological reporting of respiratory diseases caused by occupational hazards. This study aimed to establish a correlation between readings of HRCT (according to the ICOERD) and those of chest radiography (CXR) pneumoconiotic parenchymal opacities (according to the International Labor Organization Classification/International Classification of Radiographs of Pneumoconioses [ILO/ICRP]). Forty-six patients with and 28 controls without mineral dust exposure underwent posterior-anterior CXR and HRCT. We recorded all subjects' exposure and smoking history. Experts independently read CXRs (using ILO/ICRP). Experts independently assessed HRCT using the ICOERD parenchymal abnormalities grades for well-defined rounded opacities (RO), linear and/or irregular opacities (IR), and emphysema (EM). The correlation between the ICOERD summed grades and ILO/ICRP profusions was evaluated using Spearman's rank-order correlation. Twenty-three patients had small opacities on CXR. HRCT showed that 21 patients had RO; 20 patients, IR opacities; and 23 patients, EM. The correlation between ILO/ICRP profusions and the ICOERD grades was 0.844 for rounded opacities (p<0.01). ICOERD readings from HRCT scans correlated well with previously validated ILO/ICRP criteria. The ICOERD adequately detects pneumoconiotic micronodules and can be used for the interpretation of pneumoconiosis.
EPA's Reanalysis of Key Issues Related to Dioxin Toxicity and ...
EPA is releasing for external peer review and public comment an important draft document reviewing the literature on the health effects of dioxin and related compounds (also referred to as 2,3,7,8-Tetrachlorodibenzo-p-dioxin). At the request of Administrator Jackson, EPA is in the process of re-assessing the science on the effects of dioxin, a toxic chemical that is emitted by multiple sources, on the public’s health. This draft dioxin report is EPA’s response to key comments and recommendations made by the National Academy of Sciences on the Agency’s draft dioxin reassessment. This assessment has been in progress for many years and raises health issues of broad interest to scientists and policymakers across the federal family. The Agency’s draft report includes significant new analyses on potential cancer and non-cancer human health effects that may result from exposures to dioxins and includes an oral reference dose for what is considered to be the most toxic of the dioxin-like compounds. EPA’s Science
In Brief: Geoengineering draft statement
NASA Astrophysics Data System (ADS)
Showstack, Randy
2009-04-01
The American Meteorological Society (AMS) has prepared a draft policy statement on geoengineering the climate system, which the AMS Council is considering for approval. The statement notes, “Geoengineering will not substitute for either aggressive mitigation or proactive adaptation. It could contribute to a comprehensive risk management strategy to slow climate change and alleviate its negative impacts, but the potential for adverse and unintended consequences implies a need for adequate research, appropriate regulation, and transparent consideration.” The statement, if adopted, indicates that AMS recommends enhanced research on the scientific and technological potential for geoengineering the climate system; additional study of the historical, ethical, legal, political, and societal aspects of the geoengineering issues; and the development and analysis of policy options to promote transparency and international cooperation in exploring geoengineering options along with restrictions on reckless efforts to manipulate the climate system. AMS is accepting comments on the draft statement until 23 April. For more information, visit http://ametsoc.org/policy/draftstatements/index.html#draft.
Measurement of radiation exposure in relatives of thyroid cancer patients treated with (131)I.
Ramírez-Garzón, Y T; Ávila, O; Medina, L A; Gamboa-deBuen, I; Rodríguez-Laguna, A; Buenfil, A E; Ruíz-Trejo, C; Estrada, E; Brandan, M E
2014-11-01
This work evaluates the radiological risk that patients treated with I for differentiated thyroid cancer could present to relatives and occupationally exposed workers. Recently, the International Atomic Energy Agency issued document K9010241, which recommends that patient discharge from the hospital must be based on the particular status of each patient. This work measures effective dose received by caregivers of patients treated with I at the Instituto Nacional de Cancerología, Mexico City. Thermoluminescent dosimeters were carried during a 15-d period by 40 family caregivers after patient release from hospital. Relatives were classified into two groups, ambulatory and hospitalized, according to the release mode of the patient, and three categories according to the individual patient home and transport facilities. Categories A, B, and C were defined going from most to least adequate concerning public exposure risk. Measurements were performed for 20 family caregivers in each group. The effective dose received by all caregivers participating in this study was found to be less than 5 mSv, the recommended limit per event for caregivers suggested by ICRP 103. In addition, 70 and 90% of ambulatory and hospitalized groups, respectively, received doses lower than 1 mSv. Caregivers belonging to category C, with home situations that are not appropriate for immediate release, received the highest average doses; i.e., 2.2 ± 1.3 and 3.1 ± 1.0 mSv for hospitalized and ambulatory patients, respectively. Results of this work have shown that the proper implementation of radiation protection instructions for relatives and patients can reduce significantly the risk that differentiated thyroid cancer patients treated with I can represent for surrounding individuals. The results also stress the relevance of the patient's particular lifestyle and transport conditions as the prevailing factors related to the dose received by the caregiver. Therefore, the patient's status should be the criterion used to decide his/her release modality. This work provides support to recommend the implementation of the "patient specific release criteria" in accordance with ICRP 94, IAEA Safety Report No. 63, and IAE document K9010241 A for patients treated with radiopharmaceuticals.
Methods to improve routine bioassay monitoring for freshly separated, poorly transported plutonium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bihl, D.E.; Lynch, T.P.; Carbaugh, E.H.
1988-09-01
Several human cases involving inhalation of plutonium oxide at Hanford have shown clearance half-times from the lung that are much longer than the 500-day half-time recommended for class Y plutonium in Publication 30 of the International Commission on Radiological Protection(ICRP). The more tenaciously retained material is referred to as super class Y plutonium. The ability to detect super class Y plutonium by current routine bioassay measurements is shown to be poor. Pacific Northwest Laboratory staff involved in the Hanford Internal Dosimetry Program investigated four methods to se if improvements in routine monitoring of workers for fresh super class Y plutoniummore » are feasible. The methods were lung counting, urine sampling, fecal sampling, and use of diethylenetriaminepentaacetate (DTPA) to enhance urinary excretion. Use of DTPA was determined to be not feasible. Routine fecal sampling was found to be feasible but not recommended. Recommendations were made to improve the detection level for routine annual urinalysis and routine annual lung counting. 12 refs., 9 figs., 7 tabs.« less
Coates, Laura C; Kavanaugh, Arthur; Mease, Philip J; Soriano, Enrique R; Laura Acosta-Felquer, Maria; Armstrong, April W; Bautista-Molano, Wilson; Boehncke, Wolf-Henning; Campbell, Willemina; Cauli, Alberto; Espinoza, Luis R; FitzGerald, Oliver; Gladman, Dafna D; Gottlieb, Alice; Helliwell, Philip S; Husni, M Elaine; Love, Thorvardur J; Lubrano, Ennio; McHugh, Neil; Nash, Peter; Ogdie, Alexis; Orbai, Ana-Maria; Parkinson, Andrew; O'Sullivan, Denis; Rosen, Cheryl F; Schwartzman, Sergio; Siegel, Evan L; Toloza, Sergio; Tuong, William; Ritchlin, Christopher T
2016-05-01
To update the 2009 Group for Research and Assessment of Psoriasis and Psoriatic Arthritis (GRAPPA) treatment recommendations for the spectrum of manifestations affecting patients with psoriatic arthritis (PsA). GRAPPA rheumatologists, dermatologists, and PsA patients drafted overarching principles for the management of PsA, based on consensus achieved at face-to-face meetings and via online surveys. We conducted literature reviews regarding treatment for the key domains of PsA (arthritis, spondylitis, enthesitis, dactylitis, skin disease, and nail disease) and convened a new group to identify pertinent comorbidities and their effect on treatment. Finally, we drafted treatment recommendations for each of the clinical manifestations and assessed the level of agreement for the overarching principles and treatment recommendations among GRAPPA members, using an online questionnaire. Six overarching principles had ≥80% agreement among both health care professionals (n = 135) and patient research partners (n = 10). We developed treatment recommendations and a schema incorporating these principles for arthritis, spondylitis, enthesitis, dactylitis, skin disease, nail disease, and comorbidities in the setting of PsA, using the Grading of Recommendations, Assessment, Development and Evaluation process. Agreement of >80% was reached for approval of the individual recommendations and the overall schema. We present overarching principles and updated treatment recommendations for the key manifestations of PsA, including related comorbidities, based on a literature review and consensus of GRAPPA members (rheumatologists, dermatologists, other health care providers, and patient research partners). Further updates are anticipated as the therapeutic landscape in PsA evolves. © 2016, American College of Rheumatology.
Maksymowych, Walter P; Gladman, Dafna; Rahman, Proton; Boonen, Annelies; Bykerk, Vivien; Choquette, Denis; Dimond, Sherry; Fortin, Paul; Karsh, Jacob; Klinkhoff, Alice V; Mosher, Dianne; Mulholland, Ken; Olszynski, Wojciech P; Russell, Anthony S; Savage, Laurie; Shanner, Laura; Shojania, Kam; Starr, Michael; Thomson, Glen; Zummer, Michel; Inman, Robert
2007-11-01
Development of treatment recommendations for arthritis has traditionally relied on the compilation of evidence-based data by experts in the field despite recommendations by various bodies for broad stakeholder input. Our objectives were: (1) To develop evidence-based treatment recommendations for the management of spondyloarthritis (SpA) in Canada that also incorporate the perspective of multiple stakeholders. (2) To generate a procedural template for the multidisciplinary development of treatment recommendations. The process was directed by a steering committee comprising the SPARCC Executive, rheumatologists from academic and community-based practice, patient consumers, and a representative from the John Dossetor Health Ethics Centre. Guidelines established by EULAR and stipulated in the AGREE instrument were followed. First, a working document was drafted that included a referenced summary of the evidence-based data and the 12 national arthritis care standards developed by the Alliance for the Canadian Arthritis Program. Second, a Web-based survey was conducted among patient consumers to address the relevance to patients of 2 primary outcome instruments that assess the effectiveness of treatment. Third, a list of questions was generated for drafting propositions by the ethics consultant. A Delphi consensus exercise was then conducted. Consensus was generated on a final list of 38 treatment recommendations categorized under the subject headings of general management principles, ethical considerations, target groups, definition of target disease, disease monitoring, and specific management recommendations. Using broad stakeholder input, we provide treatment recommendations to guide clinical practice and access to care for patients with SpA in Canada.
Working draft of the FDA GMP final rule (Part II).
Donawa, M E
1995-11-01
Part I of this two-part series provided information on the proposed design control provisions of the US Food and Drug Administration's (FDA) working draft of the final rule for new good manufacturing practice regulations for medical devices. The final rule could be published in April or May 1996. It would be in force 180 days after the date of publication. Design control requirements may become effective some months later. This article describes recommended modifications of three provisions that have been intensely discussed during recent FDA-sponsored public meetings.
21 CFR 10.80 - Dissemination of draft Federal Register notices and regulations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... may discuss orally or in writing with an interested person ideas and recommendations for notices or regulations. FDA welcomes assistance in developing ideas for, and in gathering the information to support...
21 CFR 10.80 - Dissemination of draft Federal Register notices and regulations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... may discuss orally or in writing with an interested person ideas and recommendations for notices or regulations. FDA welcomes assistance in developing ideas for, and in gathering the information to support...
The effective dose result of 18F-FDG PET-CT paediatric patients
NASA Astrophysics Data System (ADS)
Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.
2017-05-01
Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.
Lecompte, Yannick; Bohand, Sandra; Laroche, Pierre; Cazoulat, Alain
2013-01-01
After a review of radiometric reference methods used in radiotoxicology, analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the workplace urinary diagnosis of internal contamination by radionuclides are evaluated. A literature review (covering the period from 2000 to 2012) is performed to identify the different applications of ICP-MS in radiotoxicology for urine analysis. The limits of detection are compared to the recommendations of the International commission on radiological protection (ICRP 78: "Individual monitoring for internal exposure of workers"). Except one publication describing the determination of strontium-90 (β emitter), all methods using ICP-MS reported in the literature concern actinides (α emitters). For radionuclides with a radioactive period higher than 10(4) years, limits of detection are most often in compliance with ICRP publication 78 and frequently lower than radiometric methods. ICP-MS allows the specific determination of plutonium-239 + 240 isotopes which cannot be discriminated by α spectrometry. High resolution ICP-MS can also measure uranium isotopic ratios in urine for total uranium concentrations lower than 20 ng/L. The interest of ICP-MS in radiotoxicology concerns essentially the urinary measurement of long radioactive period actinides, particularly for uranium isotope ratio determination and 239 and 240 plutonium isotopes discrimination. Radiometric methods remain the most efficient for the majority of other radionuclides.
Federal Register for Sustainable and Healthy Communities Subcommittee Teleconference
The Sustainable and Healthy Communities (SHC) Subcommittee will host a public teleconference meeting on Wednesday, November 4, 2015, that will focus on a draft report summarizing the findings and recommendations from its September 2015 meeting.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-15
... that underlie many complex diseases, such as cancer, cardiovascular disease, and infectious diseases... used in combination to treat a disease or condition. This guidance provides recommendations and advice...
ERIC Educational Resources Information Center
AAUP Bulletin, 1975
1975-01-01
A report of the Committee on Freedom of Expression at Yale appointed by the president to examine the condition of free expression, peaceful dissent, mutual respect and tolerance at Yale and to draft recommendations for maintenance of those principles. (JT)
Monitoring Well Development Guidelines for Superfund Project Managers
This document provides well development guidelines and recommended additional sources of information. It was developed by the Supertund Ground Water Forum and draws upon U.S. Army Corps of Engineersand draft RCRA SW-846 field protocols. Comments..
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-23
... provides industry and agency staff with updated recommendations concerning 510(k) submissions for various... will be relevant for premarket notification (510(k)) submissions for these device types. Detection...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
... protected areas. The AP will provide recommendations on measures for inclusion into a public hearing draft... meeting is physically accessible to people with disabilities. Requests for auxiliary aids should be...
Radon exposure assessment for underground workers: a case of Seoul Subway Police officers in Korea.
Song, Myeong Han; Chang, Byung-Uck; Kim, Yongjae; Cho, Kun-Woo
2011-11-01
The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq·m(-3) in their workplaces. The total annual effective doses which may likely to be received on duty were assessed to be in the range of 0.41-1.64 mSv·y(-1). These were well below the recommended action level 10 mSv·y(-1) by ICRP. However, the effective doses were higher than subway station staff in Seoul, Korea.
O'Brien, Kelly K; Solomon, Patricia; Trentham, Barry; MacLachlan, Duncan; MacDermid, Joy; Tynan, Anne-Marie; Baxter, Larry; Casey, Alan; Chegwidden, William; Robinson, Greg; Tran, Todd; Wu, Janet; Zack, Elisse
2014-01-01
Objective Our aim was to develop evidence-informed recommendations for rehabilitation with older adults living with HIV. Design We conducted a knowledge synthesis, combining research evidence specific to HIV, rehabilitation and ageing, with evidence on rehabilitation interventions for common comorbidities experienced by older adults with HIV. Methods We included highly relevant HIV-specific research addressing rehabilitation and ageing (stream A) and high-quality evidence on the effectiveness of rehabilitation interventions for common comorbidities experienced by older adults ageing with HIV (stream B). We extracted and synthesised relevant data from the evidence to draft evidence-informed recommendations for rehabilitation. Draft recommendations were refined based on people living with HIV (PLHIV) and clinician experience, values and preferences, reviewed by an interprofessional team for Grading of Recommendations Assessment, Development, and Evaluation (GRADE) (quality) rating and revision and then circulated to PLHIV and clinicians for external endorsement and final refinement. We then devised overarching recommendations to broadly guide rehabilitation with older adults living with HIV. Results This synthesis yielded 8 overarching and 52 specific recommendations. Thirty-six specific recommendations were derived from 108 moderate-level or high-level research articles (meta-analyses and systematic reviews) that described the effectiveness of rehabilitation interventions for comorbidities that may be experienced by older adults with HIV. Recommendations addressed rehabilitation interventions across eight health conditions: bone and joint disorders, cancer, stroke, cardiovascular disease, mental health challenges, cognitive impairments, chronic obstructive pulmonary disease and diabetes. Sixteen specific recommendations were derived from 42 research articles specific to rehabilitation with older adults with HIV. The quality of evidence from which these recommendations were derived was either low or very low, consisting primarily of narrative reviews or descriptive studies with small sample sizes. Recommendations addressed approaches to rehabilitation assessment and interventions, and contextual factors to consider for rehabilitation with older adults living with HIV. Conclusions These evidence-informed recommendations provide a guide for rehabilitation with older adults living with HIV. PMID:24833687
MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolch, Wesley
The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2’s Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2’s revision of the target tissues of relevance for radiogenicmore » bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-μm cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-μm layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public« less
Ali, Ahmed Yousif M; Safwat, Tarek; Onyemelukwe, Geoffrey; Otaibi, Moh'd Amin Al; Amir, Ashraf A; Nawas, Yousef N; Aouina, Hichem; Afif, Moulay Hicham; Bolliger, Chris T
2012-01-01
Despite the abundance of scientific evidence confirming the health consequences of smoking and other forms of tobacco use, the tobacco epidemic remains an important public health problem and by 2030 it is predicted that more than 80% of tobacco deaths will be in developing countries. In Africa and the Middle East, many local factors contribute to the initiation and maintenance of tobacco use. Although efforts to reduce the mortality and morbidity associated with smoking and tobacco dependence are underway, there is a need for guidance on how to utilize appropriate tobacco control policies and psychology- and pharmacology-based therapies to counter tobacco dependence as recommended by the Framework Convention on Tobacco Control (FCTC). A group of tobacco cessation experts from public health services and/or academic institutions in Africa and the Middle East participated in a series of four meetings held in Cairo, Cape Town, and Dubai between May 2008 and February 2011 to develop a draft guideline tailored to their region. This article provides the background to the development of this draft smoking cessation guideline and discusses how the recommendations can be implemented and progress monitored to promote both primary prevention and cessation of tobacco use within our countries. The draft guideline for Africa and the Middle East provides an important resource in combating the devastating effects of tobacco use in these regions which can be further localized through engagement with local stakeholders in the countries of the region. Copyright © 2012 S. Karger AG, Basel.
Okely, Anthony D; Ghersi, Davina; Hesketh, Kylie D; Santos, Rute; Loughran, Sarah P; Cliff, Dylan P; Shilton, Trevor; Grant, David; Jones, Rachel A; Stanley, Rebecca M; Sherring, Julie; Hinkley, Trina; Trost, Stewart G; McHugh, Clare; Eckermann, Simon; Thorpe, Karen; Waters, Karen; Olds, Timothy S; Mackey, Tracy; Livingstone, Rhonda; Christian, Hayley; Carr, Harriette; Verrender, Adam; Pereira, João R; Zhang, Zhiguang; Downing, Katherine L; Tremblay, Mark S
2017-11-20
In 2017, the Australian Government funded the update of the National Physical Activity Recommendations for Children 0-5 years, with the intention that they be an integration of movement behaviours across the 24-h period. The benefit for Australia was that it could leverage research in Canada in the development of their 24-h guidelines for the early years. Concurrently, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) working group published a model to produce guidelines based on adoption, adaption and/or de novo development using the GRADE evidence-to-decision framework. Referred to as the GRADE-ADOLOPMENT approach, it allows guideline developers to follow a structured and transparent process in a more efficient manner, potentially avoiding the need to unnecessarily repeat costly tasks such as conducting systematic reviews. The purpose of this paper is to outline the process and outcomes for adapting the Canadian 24-Hour Movement Guidelines for the Early Years to develop the Australian 24-Hour Movement Guidelines for the Early Years guided by the GRADE-ADOLOPMENT framework. The development process was guided by the GRADE-ADOLOPMENT approach. A Leadership Group and Consensus Panel were formed and existing credible guidelines identified. The draft Canadian 24-h integrated movement guidelines for the early years best met the criteria established by the Panel. These were evaluated based on the evidence in the GRADE tables, summaries of findings tables and draft recommendations from the Canadian Draft Guidelines. Updates to each of the Canadian systematic reviews were conducted and the Consensus Panel reviewed the evidence for each behaviour separately and made a decision to adopt or adapt the Canadian recommendations for each behaviour or create de novo recommendations. An online survey was then conducted (n = 302) along with five focus groups (n = 30) and five key informant interviews (n = 5) to obtain feedback from stakeholders on the draft guidelines. Based on the evidence from the Canadian systematic reviews and the updated systematic reviews in Australia, the Consensus Panel agreed to adopt the Canadian recommendations and, apart from some minor changes to the wording of good practice statements, keep the wording of the guidelines, preamble and title of the Canadian Guidelines. The Australian Guidelines provide evidence-informed recommendations for a healthy day (24-h), integrating physical activity, sedentary behaviour (including limits to screen time), and sleep for infants (<1 year), toddlers (1-2 years) and preschoolers (3-5 years). To our knowledge, this is only the second time the GRADE-ADOLOPMENT approach has been used. Following this approach, the judgments of the Australian Consensus Panel did not differ sufficiently to change the directions and strength of the recommendations and as such, the Canadian recommendations were adopted with very minor alterations. This allowed the Guidelines to be developed much faster and at lower cost. As such, we would recommend the GRADE-ADOLOPMENT approach, especially if a credible set of guidelines, with all supporting materials and developed using a transparent process, is available. Other countries may consider using this approach when developing and/or revising national movement guidelines.
Assessment and management of nutrition and growth in Rett syndrome
Leonard, Helen; Ravikumara, Madhur; Baikie, Gordon; Naseem, Nusrat; Ellaway, Carolyn; Percy, Alan; Abraham, Suzanne; Geerts, Suzanne; Lane, Jane; Jones, Mary; Bathgate, Katherine; Downs, Jenny
2014-01-01
Objectives We developed recommendations for the clinical management of poor growth and weight gain in Rett syndrome through evidence review and the consensus of an expert panel of clinicians. Methods Initial draft recommendations were created based upon literature review and 34 open-ended questions where the literature was lacking. Statements and questions were made available to an international, multi-disciplinary panel of clinicians in an online format and a Microsoft Word formatted version of the draft via email. Input was sought using a 2-stage modified Delphi process to reach consensus agreement. Items included clinical assessment of growth, anthropometry, feeding difficulties and management to increase caloric intake, decrease feeding difficulties and consideration of gastrostomy. Results Agreement was achieved on 101/112 statements. A comprehensive approach to the management of poor growth in Rett syndrome is recommended that takes into account factors such as feeding difficulties and nutritional needs. A BMI of approximately the 25th centile can be considered as a reasonable target in clinical practice. Gastrostomy is indicated for very poor growth, if there is risk of aspiration and if feeding times are prolonged. Conclusions These evidence- and consensus-based recommendations have the potential to improve care of nutrition and growth in a rare condition and stimulate research to improve the current limited evidence base. PMID:24084372
A biokinetic model for systemic nickel
Melo, Dunstana; Leggett, Richard Wayne
2017-01-01
The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less
A biokinetic model for systemic nickel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melo, Dunstana; Leggett, Richard Wayne
The International Commission on Radiological Protection (ICRP) is updating its suite of reference biokinetic models for internally deposited radionuclides. This paper reviews data for nickel and proposes an updated biokinetic model for systemic (absorbed) nickel in adult humans for use in radiation protection. Compared with the ICRP s current model for nickel, the proposed model is based on a larger set of observations of the behavior of nickel in human subjects and laboratory animals and provides a more realistic description of the paths of movement of nickel in the body. For the two most important radioisotopes of nickel, 59Ni andmore » 63Ni, the proposed model yields substantially lower dose estimates per unit of activity reaching blood than the current ICRP model.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
... CONTACT: Subhas Malghan, Center for Devices and Radiological Health, Food and Drug Administration, 10903... respiratory ailments, and development of irritant dermatitis or Type IV allergy when glove powder is used on...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-27
...), Food and Drug Administration, 7519 Standish Pl., Rockville, MD 20855, 240-276-8465. SUPPLEMENTARY... in the Division of Dockets Management between 9 a.m. and 4 p.m., Monday through Friday, and will be...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-20
... carcinogenicity study performed by the National Toxicology Program. The new data suggest a positive systemic... alternative approach may be used if such approach satisfies the requirements of the applicable statutes and...
Rodrigues, A M; Canhão, H; Marques, A; Ambrósio, C; Borges, J; Coelho, P; Costa, L; Fernandes, S; Gonçalves, I; Gonçalves, M; Guerra, M; Marques, M L; Pimenta, S; Pinto, P; Sequeira, G; Simões, E; Teixeira, L; Vaz, C; Vieira-Sousa, E; Vieira, R; Alvarenga, F; Araújo, F; Barcelos, A; Barcelos, F; Barros, R; Bernardes, M; Canas da Silva, J; Cordeiro, A; Costa, M; Cunha-Miranda, L; Cruz, M; Duarte, A C; Duarte, C; Faustino, A; Figueiredo, G; Fonseca, J E; Furtado, C; Gomes, J; Lopes, C; Mourão, A F; Oliveira, M; Pimentel-Santos, F M; Ribeiro, A; Sampaio da Nóvoa, T; Santiago, M; Silva, C; Silva-Dinis, A; Sousa, S; Tavares-Costa, J; Terroso, G; Vilar, A; Branco, J C; Tavares, V; Romeu, J C; da Silva, Jap
2018-01-01
Advances in osteoporosis (OP)case definition, treatment options, optimal therapy duration and pharmacoeconomic evidence in the national context motivated the Portuguese Society of Rheumatology (SPR) to update the Portuguese recommendations for the diagnosis and management of osteoporosis published in 2007. SPR bone diseases' working group organized meetings involving 55 participants (rheumatologists, rheumatology fellows and one OP specialist nurse) to debate and develop the document. First, the working group selected 11 pertinent clinical questions for the diagnosis and management of osteoporosis in standard clinical practice. Then, each question was investigated through literature review and draft recommendations were built through consensus. When insufficient evidence was available, recommendations were based on experts' opinion and on good clinical practice. At two national meetings, the recommendations were discussed and updated. A draft of the recommendations full text was submitted to critical review among the working group and suggestions were incorporated. A final version was circulated among all Portuguese rheumatologists before publication and the level of agreement was anonymously assessed using an online survey. The 2018 SPR recommendations provide comprehensive guidance on osteoporosis prevention, diagnosis, fracture risk assessment, pharmacological treatment initiation, therapy options and duration of treatment, based on the best available evidence. They attained desirable agreement among Portuguese rheumatologists. As more evidence becomes available, periodic revisions will be performed. Target audience and patient population: The target audience for these guidelines includes all clinicians. The target patient population includes adult Portuguese people. Intended use: These recommendations provide general guidance for typical cases. They may not be appropriate in all situations - clinicians are encouraged to consider this information together with updated evidence and their best clinical judgment in individual cases.
Lang, Eddy S; Artz, Jennifer D; Wilkie, Ryan D; Stiell, Ian G; Topping, Claude; Belanger, François P; Afilalo, Marc; Renouf, Tia; Crocco, Anthony; Wyatt, Kelly; Christenson, Jim
2016-05-01
To describe the current state of academic emergency medicine (EM) funding in Canada and develop recommendations to grow and establish sustainable funding. A panel of eight leaders from different EM academic units was assembled. Using mixed methods (including a literature review, sharing of professional experiences, a survey of current EM academic heads, and data previously collected from an environmental scan), 10 recommendations were drafted and presented at an academic symposium. Attendee feedback was incorporated, and the second set of draft recommendations was further distributed to the Canadian Association Emergency Physicians (CAEP) Academic Section for additional comments before being finalized. Recommendations were developed around the funding challenges identified and solutions developed by academic EM university-based units across Canada. A strategic plan was seen as integral to achieving strong funding of an EM unit, especially when it aligned with departmental and institutional priorities. A business plan, although occasionally overlooked, was deemed an important component for planning and sustaining the academic mission. A number of recommendations surrounding philanthropy consisted of creating partnerships with existing foundations and engaging multiple stakeholders and communities. Synergy between academic and clinical EM departments was also viewed as an opportunity to ensure integration of common missions. Education and networking for current and future leaders were also viewed as invaluable to ensure that opportunities are optimized through strong leadership development and shared experiences to further the EM academic missions across the country. These recommendations were designed to improve the financial circumstances for many Canadian EM units. There is a considerable wealth of resources that can contribute to financial stability for an academic unit, and an annual networking meeting and continuing education on these issues will facilitate more rapid implementation of these recommendations.
Yucca Mountain nuclear waste repository prompts heated congressional hearing
NASA Astrophysics Data System (ADS)
Showstack, Randy
2011-11-01
Although the final report of the Blue Ribbon Commission on America's Nuclear Future is not expected until January 2012, the tentative conclusions of the commission's draft report were dissected during a recent joint hearing by two subcommittees of the House of Representatives' Committee on Science, Space, and Technology. Among the more heated issues debated at the hearing was the fate of the stalled Yucca Mountain nuclear waste repository in Nevada. The Blue Ribbon Commission's (BRC) draft report includes recommendations for managing nuclear waste and for developing one or more permanent deep geological repositories and interim storage facilities, but the report does not address the future of Yucca Mountain. The BRC charter indicates that the commission is to "conduct a comprehensive review of policies for managing the back end of the nuclear fuel cycle." However, the draft report states that the commission was not asked to consider, and therefore did not address, several key issues. "We have not rendered an opinion on the suitability of the Yucca Mountain site or on the request to withdraw the license application for Yucca Mountain," the draft report states.
Evolution of modern approaches to express uncertainty in measurement
NASA Astrophysics Data System (ADS)
Kacker, Raghu; Sommer, Klaus-Dieter; Kessel, Rüdiger
2007-12-01
An object of this paper is to discuss the logical development of the concept of uncertainty in measurement and the methods for its quantification from the classical error analysis to the modern approaches based on the Guide to the Expression of Uncertainty in Measurement (GUM). We review authoritative literature on error analysis and then discuss its limitations which motivated the experts from the International Committee for Weights and Measures (CIPM), the International Bureau of Weights and Measures (BIPM) and various national metrology institutes to develop specific recommendations which form the basis of the GUM. We discuss the new concepts introduced by the GUM and their merits and limitations. The limitations of the GUM led the BIPM Joint Committee on Guides in Metrology to develop an alternative approach—the draft Supplement 1 to the GUM (draft GUM-S1). We discuss the draft GUM-S1 and its merits and limitations. We hope this discussion will lead to a more effective use of the GUM and the draft GUM-S1 and stimulate investigations leading to further improvements in the methods to quantify uncertainty in measurement.
A TIERED APPROACH TO PERFORMING UNCERTAINTY ANALYSIS IN CONDUCTING EXPOSURE ANALYSIS FOR CHEMICALS
The WHO/IPCS draft Guidance Document on Characterizing and Communicating Uncertainty in Exposure Assessment provides guidance on recommended strategies for conducting uncertainty analysis as part of human exposure analysis. Specifically, a tiered approach to uncertainty analysis ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-06
... scientific workshop. In addition, FDA is aware that dengue viruses are endemic in Quintana Roo and Jalisco. FDA is currently evaluating the risk of dengue virus infections in U.S. blood donors that are acquired...
IRIS Toxicological Review of Formaldehyde (Inhalation) (External Review Draft 2010)
UPDATE EPA is currently revising its Integrated Risk Information System (IRIS) assessment of formaldehyde to address the 2011 NAS peer review recommendations. This assessment addresses both noncancer and cancer human health effects that are relevant to assessing ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-06
... Arctic Heritage Center, 171 Third Avenue in Kotzebue, Alaska, (907) 442-3890, on Thursday, November 17...' Workshop. 12. New Business. a. Gates of the Arctic National Park SRC Draft Hunting Plan Recommendation 10...
76 FR 4113 - Independent Scientific Peer Review Panel Meeting on an In Vitro
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-24
... Vitro Estrogen Receptor Transcriptional Activation Test Method for Endocrine Disruptor Chemical... Vitro Estrogen Receptor Transcriptional Activation Test Method for Endocrine Disruptor Chemical... the information included in the BRD supports ICCVAM's draft test method recommendations. NICEATM...
Santos, J A M; Nunes, R
2011-03-01
The International Commission on Radiological Protection recommendations for occupational exposed pregnant women do not imply necessarily the complete avoidance of work with radiation or radioactive materials. Instead, a careful review of the exposure conditions, once the pregnancy is declared, as part of the exercise of the ICRP optimisation principle (based in a teleological ethics point of view) is suggested. The dose limitation (following a deontological ethics point of view) of the fetus/embryo is, however, not clearly well established as happens in the case of workers or members of the public. Also, the justification of practices (to continue to work or not with radiation or radioactive materials) is not clearly addressed in most national or international recommendations. An analysis of this justification (bearing in mind both teleological and deontological ethics) is examined in this work having in mind the best interest of the child-to-be as well as other existing social and economical factors.
Hybrid pregnant reference phantom series based on adult female ICRP reference phantom
NASA Astrophysics Data System (ADS)
Rafat-Motavalli, Laleh; Miri-Hakimabad, Hashem; Hoseinian-Azghadi, Elie
2018-03-01
This paper presents boundary representation (BREP) models of pregnant female and her fetus at the end of each trimester. The International Commission on Radiological Protection (ICRP) female reference voxel phantom was used as a base template in development process of the pregnant hybrid phantom series. The differences in shape and location of the displaced maternal organs caused by enlarging uterus were also taken into account. The CT and MR images of fetus specimens and pregnant patients of various ages were used to replace the maternal abdominal pelvic organs of template phantom and insert the fetus inside the gravid uterus. Each fetal model contains 21 different organs and tissues. The skeletal model of the fetus also includes age-dependent cartilaginous and ossified skeletal components. The replaced maternal organ models were converted to NURBS surfaces and then modified to conform to reference values of ICRP Publication 89. The particular feature of current series compared to the previously developed pregnant phantoms is being constructed upon the basis of ICRP reference phantom. The maternal replaced organ models are NURBS surfaces. With this great potential, they might have the feasibility of being converted to high quality polygon mesh phantoms.
Coronado-Cerda, Erika Evangelina; Franco-Molina, Moisés Armides; Mendoza-Gamboa, Edgar; Prado-García, Heriberto; Rivera-Morales, Lydia Guadalupe; Zapata-Benavides, Pablo; Rodríguez-Salazar, María del Carmen; Caballero-Hernandez, Diana; Tamez-Guerra, Reyes Silvestre; Rodríguez-Padilla, Cristina
2016-01-01
Chemotherapy treatments induce a number of side effects, such as leukopenia neutropenia, peripheral erythropenia, and thrombocytopenia, affecting the quality of life for cancer patients. 5-Fluorouracil (5-FU) is wieldy used as myeloablative model in mice. The bovine dialyzable leukocyte extract (bDLE) or IMMUNEPOTENT CRP® (ICRP) is an immunomodulatory compound that has antioxidants and anti-inflammatory effects. In order to investigate the chemoprotection effect of ICRP on bone marrow cells in 5-FU treated mice, total bone marrow (BM) cell count, bone marrow colony forming units-granulocyte/macrophage (CFU-GM), cell cycle, immunophenotypification, ROS/superoxide and Nrf2 by flow cytometry, and histological and hematological analyses were performed. Our results demonstrated that ICRP increased BM cell count and CFU-GM number, arrested BM cells in G0/G1 phase, increased the percentage of leukocyte, granulocytic, and erythroid populations, reduced ROS/superoxide formation and Nrf2 activation, and also improved hematological levels and weight gain in 5-FU treated mice. These results suggest that ICRP has a chemoprotective effect against 5-FU in BM cells that can be used in cancer patients. PMID:27191003
An age dependent model for radium metabolism in man.
Johnson, J R
1983-01-01
The model developed by a Task Group of Committee 2 of ICRP to describe Alkaline Earth Metabolism in Adult Man (ICRP Publication 20) has been modified so that recycling is handled explicitly, and retention in mineral bone is represented by second compartments rather than by the product of a power function and an exponential. This model has been extended to include all ages from birth to adult man, and has been coupled with modified "ICRP" lung and G.I. tract models so that activity in organs can be calculated as functions of time during or after exposures. These activities, and age dependent "specific effective energy" factors, are then used to calculate age dependent dose rates, and dose commitments. This presentation describes this work, with emphasis on the model parameters and results obtained for radium.
Computational lymphatic node models in pediatric and adult hybrid phantoms for radiation dosimetry
NASA Astrophysics Data System (ADS)
Lee, Choonsik; Lamart, Stephanie; Moroz, Brian E.
2013-03-01
We developed models of lymphatic nodes for six pediatric and two adult hybrid computational phantoms to calculate the lymphatic node dose estimates from external and internal radiation exposures. We derived the number of lymphatic nodes from the recommendations in International Commission on Radiological Protection (ICRP) Publications 23 and 89 at 16 cluster locations for the lymphatic nodes: extrathoracic, cervical, thoracic (upper and lower), breast (left and right), mesentery (left and right), axillary (left and right), cubital (left and right), inguinal (left and right) and popliteal (left and right), for different ages (newborn, 1-, 5-, 10-, 15-year-old and adult). We modeled each lymphatic node within the voxel format of the hybrid phantoms by assuming that all nodes have identical size derived from published data except narrow cluster sites. The lymph nodes were generated by the following algorithm: (1) selection of the lymph node site among the 16 cluster sites; (2) random sampling of the location of the lymph node within a spherical space centered at the chosen cluster site; (3) creation of the sphere or ovoid of tissue representing the node based on lymphatic node characteristics defined in ICRP Publications 23 and 89. We created lymph nodes until the pre-defined number of lymphatic nodes at the selected cluster site was reached. This algorithm was applied to pediatric (newborn, 1-, 5-and 10-year-old male, and 15-year-old males) and adult male and female ICRP-compliant hybrid phantoms after voxelization. To assess the performance of our models for internal dosimetry, we calculated dose conversion coefficients, called S values, for selected organs and tissues with Iodine-131 distributed in six lymphatic node cluster sites using MCNPX2.6, a well validated Monte Carlo radiation transport code. Our analysis of the calculations indicates that the S values were significantly affected by the location of the lymph node clusters and that the values increased for smaller phantoms due to the shorter inter-organ distances compared to the bigger phantoms. By testing sensitivity of S values to random sampling and voxel resolution, we confirmed that the lymph node model is reasonably stable and consistent for different random samplings and voxel resolutions.
NASA Astrophysics Data System (ADS)
Zhang, Guozhi; Liu, Qian; Zeng, Shaoqun; Luo, Qingming
2008-07-01
The voxel-based visible Chinese human (VCH) adult male phantom has offered a high-quality test bed for realistic Monte Carlo modeling in radiological dosimetry simulations. The phantom has been updated in recent effort by adding newly segmented organs, revising walled and smaller structures as well as recalibrating skeletal marrow distributions. The organ absorbed dose against external proton exposure was calculated at a voxel resolution of 2 × 2 × 2 mm3 using the MCNPX code for incident energies from 20 MeV to 10 GeV and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO), respectively. The effective dose on the VCH phantom was derived in compliance with the evaluation scheme for the reference male proposed in the 2007 recommendations of the International Commission on Radiological Protection (ICRP). Algorithm transitions from the revised radiation and tissue weighting factors are accountable for approximately 90% and 10% of effective dose discrepancies in proton dosimetry, respectively. Results are tabulated in terms of fluence-to-dose conversion coefficients for practical use and are compared with data from other models available in the literature. Anatomical variations between various computational phantoms lead to dose discrepancies ranging from a negligible level to 100% or more at proton energies below 200 MeV, corresponding to the spatial geometric locations of individual organs within the body. Doses show better agreement at higher energies and the deviations are mostly within 20%, to which the organ volume and mass differences should be of primary responsibility. The impact of body size on dose distributions was assessed by dosimetry of a scaled-up VCH phantom that was resized in accordance with the height and total mass of the ICRP reference man. The organ dose decreases with the directionally uniform enlargement of voxels. Potential pathways to improve the VCH phantom have also been briefly addressed. This work pertains to VCH-based systematic multi-particle dose investigations and will contribute to comparative dosimetry studies of ICRP standardized voxel phantoms in the near future.
Burn disaster response planning: an urban region's approach.
Yurt, Roger W; Lazar, Eliot J; Leahy, Nicole E; Cagliuso, Nicholas V; Rabbitts, Angela C; Akkapeddi, Vijay; Cooper, Arthur; Dajer, Antonio; Delaney, Jack; Mineo, Frank P; Silber, Steven H; Soloff, Lewis; Magbitang, Kevin; Mozingo, David W
2008-01-01
The objective of this study was to describe a draft response plan for the tiered triage, treatment, or transportation of 400 adult and pediatric victims (50/million population) of a burn disaster for the first 3 to 5 days after injury using regional resources. Review of meeting minutes and the 11 deliverables of the draft response plan was performed. The draft burn disaster response plan developed for NYC recommended: 1) City hospitals or regional burn centers within a 60-mile distance be designated as tiered Burn Disaster Receiving Hospitals (BDRH); 2) these hospitals be divided into a four-tier system, based on clinical resources; and 3) burn care supplies be provided to Tier 3 nonburn centers. Existing burn center referral guidelines were modified into a hierarchical BDRH matrix, which would vector certain patients to local or regional burn centers for initial care until capacity is reached; the remainder would be cared for in nonburn center facilities for up to 3 to 5 days until a city, regional, or national burn bed becomes available. Interfacility triage would be coordinated by a central team. Although recommendations for patient transportation, educational initiatives for prehospital and hospital providers, city-wide, interfacility or interagency communication strategies and coordination at the State or Federal levels were outlined, future initiatives will expound on these issues. An incident resulting in critically injured burn victims exceeding the capacity of local and regional burn center beds may be a reality within any community and warrants a planned response. To address this possibility within New York City, an initial draft of a burn disaster response has been created. A scaleable plan using local, state, regional, or federal health care and governmental institutions was developed.
Canadian guideline for safe and effective use of opioids for chronic noncancer pain
Kahan, Meldon; Mailis-Gagnon, Angela; Wilson, Lynn; Srivastava, Anita
2011-01-01
Abstract Objective To provide family physicians with a practical clinical summary of the Canadian Guideline for Safe and Effective Use of Opioids for Chronic Non-Cancer Pain, developed by the National Opioid Use Guideline Group. Quality of evidence Researchers for the guideline conducted a systematic review of the literature on the effectiveness and safety of opioids for chronic noncancer pain, and drafted a series of recommendations. A panel of 49 clinicians from across Canada reviewed the draft and achieved consensus on 24 recommendations. Main message Screening for addiction risk is recommended before prescribing opioids. Weak opioids (codeine and tramadol) are recommended for mild to moderate pain that has not responded to first-line treatments. Oxycodone, hydromorphone, and morphine can be tried in patients who have not responded to weaker opioids. A low initial dose and slow upward titration is recommended, with patient education and close monitoring. Physicians should watch for the development of complications such as sleep apnea. The optimal dose is one which improves function or decreases pain ratings by at least 30%. For by far most patients, the optimal dose will be well below a 200-mg morphine equivalent dose per day. Tapering is recommended for patients who have not responded to an adequate opioid trial. Conclusion Opioids play an important role in the management of chronic noncancer pain, but careful prescribing is needed to limit potential harms. The new Canadian guideline provides much-needed guidance to help physicians achieve a balance between optimal pain control and safety. PMID:22084455
Kahan, Meldon; Mailis-Gagnon, Angela; Wilson, Lynn; Srivastava, Anita
2011-11-01
To provide family physicians with a practical clinical summary of the Canadian Guideline for Safe and Effective Use of Opioids for Chronic Non-Cancer Pain, developed by the National Opioid Use Guideline Group. Researchers for the guideline conducted a systematic review of the literature on the effectiveness and safety of opioids for chronic noncancer pain, and drafted a series of recommendations. A panel of 49 clinicians from across Canada reviewed the draft and achieved consensus on 24 recommendations. Screening for addiction risk is recommended before prescribing opioids. Weak opioids (codeine and tramadol) are recommended for mild to moderate pain that has not responded to first-line treatments. Oxycodone, hydromorphone, and morphine can be tried in patients who have not responded to weaker opioids. A low initial dose and slow upward titration is recommended, with patient education and close monitoring. Physicians should watch for the development of complications such as sleep apnea. The optimal dose is one which improves function or decreases pain ratings by at least 30%. For by far most patients, the optimal dose will be well below a 200-mg morphine equivalent dose per day. Tapering is recommended for patients who have not responded to an adequate opioid trial. Opioids play an important role in the management of chronic noncancer pain, but careful prescribing is needed to limit potential harms. The new Canadian guideline provides much-needed guidance to help physicians achieve a balance between optimal pain control and safety.
78 FR 54949 - Major Project Financial Plan Guidance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
...'' (GA-090-751). That report recommended that Financial Plans include the cost of financing the project... Project Financial Plan Guidance AGENCY: Federal Highway Administration (FHWA), DOT. ACTION: Notice; Request for comments. SUMMARY: This notice requests comments on draft Major Project Financial Plan...
76 FR 59449 - Advisory Committee on Reactor Safeguards; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-26
... Recommendations on the Near-Term Task Force Report Regarding the Events at the Fukushima Dai-ichi Site in Japan... the Fukushima Dai-ichi site in Japan. 10:15 a.m.-11:45 a.m.: Development of Draft Fire Human...
77 FR 26562 - Mobile Offshore Drilling Unit Dynamic Positioning Guidance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... regarding a draft policy letter on Dynamic Positioning (DP) Systems, Emergency Disconnect Systems, Blowout... Coast Guard, NOSAC issued the report ``Recommendations for Dynamic Positioning System Design and... DEPARTMENT OF HOMELAND SECURITY Coast Guard [USCG-2011-1106] Mobile Offshore Drilling Unit Dynamic...
42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?
Code of Federal Regulations, 2010 CFR
2010-10-01
... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...
42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?
Code of Federal Regulations, 2011 CFR
2011-10-01
... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...
42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?
Code of Federal Regulations, 2013 CFR
2013-10-01
... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...
42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?
Code of Federal Regulations, 2014 CFR
2014-10-01
... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...
42 CFR 82.18 - How will NIOSH calculate internal dose to the primary cancer site(s)?
Code of Federal Regulations, 2012 CFR
2012-10-01
... primary cancer site(s)? 82.18 Section 82.18 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND... Dose Reconstruction Process § 82.18 How will NIOSH calculate internal dose to the primary cancer site(s... cancer covered by a claim is in a tissue not covered by existing ICRP models, NIOSH will use the ICRP...
Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli
2017-03-21
The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm -2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an individual organ and the body mass between the Chinese and the ICRP adult reference phantoms. These monoenergetic photon conversion coefficients are subsequently used to evaluate radionuclides with decay data from ICRP publication 107.
An image-based skeletal tissue model for the ICRP reference newborn
NASA Astrophysics Data System (ADS)
Pafundi, Deanna; Lee, Choonsik; Watchman, Christopher; Bourke, Vincent; Aris, John; Shagina, Natalia; Harrison, John; Fell, Tim; Bolch, Wesley
2009-07-01
Hybrid phantoms represent a third generation of computational models of human anatomy needed for dose assessment in both external and internal radiation exposures. Recently, we presented the first whole-body hybrid phantom of the ICRP reference newborn with a skeleton constructed from both non-uniform rational B-spline and polygon-mesh surfaces (Lee et al 2007 Phys. Med. Biol. 52 3309-33). The skeleton in that model included regions of cartilage and fibrous connective tissue, with the remainder given as a homogenous mixture of cortical and trabecular bone, active marrow and miscellaneous skeletal tissues. In the present study, we present a comprehensive skeletal tissue model of the ICRP reference newborn to permit a heterogeneous representation of the skeleton in that hybrid phantom set—both male and female—that explicitly includes a delineation of cortical bone so that marrow shielding effects are correctly modeled for low-energy photons incident upon the newborn skeleton. Data sources for the tissue model were threefold. First, skeletal site-dependent volumes of homogeneous bone were obtained from whole-cadaver CT image analyses. Second, selected newborn bone specimens were acquired at autopsy and subjected to micro-CT image analysis to derive model parameters of the marrow cavity and bone trabecular 3D microarchitecture. Third, data given in ICRP Publications 70 and 89 were selected to match reference values on total skeletal tissue mass. Active marrow distributions were found to be in reasonable agreement with those given previously by the ICRP. However, significant differences were seen in total skeletal and site-specific masses of trabecular and cortical bone between the current and ICRP newborn skeletal tissue models. The latter utilizes an age-independent ratio of 80%/20% cortical and trabecular bone for the reference newborn. In the current study, a ratio closer to 40%/60% is used based upon newborn CT and micro-CT skeletal image analyses. These changes in mineral bone composition may have significant dosimetric implications when considering localized marrow dosimetry for radionuclides that target mineral bone in the newborn child.
NASA Astrophysics Data System (ADS)
Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli
2017-03-01
The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm-2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an individual organ and the body mass between the Chinese and the ICRP adult reference phantoms. These monoenergetic photon conversion coefficients are subsequently used to evaluate radionuclides with decay data from ICRP publication 107.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeslbagg, Y. Ue.; Kuecuekoemeroglu, A.; Kurnaz, A.
Indoor radon studies have been conducted in Artvin, Eastern alack sea region of Turkey using SSNTD type nuclear track detector (CR-39). Radon measurements were done for 4 seasons in 73 dwellings, selected as uniformly distributed as possible. The radon concentrations vary from 21 aq m{sup -3} to 321 aq m{sup -3} with the annual mean concentration of 132 aq m{sup -3} for Artvin. Seasonal variation indoor radon shows high in winter low values in summer. The resulting estimated annual effective dose-equivalent due to inhalation of radon for inhabitants is 3.32 mSv y{sup -1} and the total annual effective dose liesmore » in the range of the action level (3-10 mSv y{sup -1}) recommended by the ICRP.« less
Regulating exposure of the lens of the eye to ionising radiations.
Thorne, M C
2012-06-01
The International Commission on Radiological Protection (ICRP) has reviewed recent epidemiological evidence suggesting that, for the lens of the eye, the threshold in absorbed dose for the induction of deleterious health effects is about 0.5 Gy. On this basis, the Commission recommends that for occupational exposure in planned exposure situations, the equivalent dose limit for the lens of the eye should be 20 mSv in a year, averaged over defined periods of 5 yr, with exposure not exceeding 50 mSv in any single year. This paper summarises the data that have been taken into account by the ICRP and critically examines whether the proposed downward revision of the dose limit is justified. Overall, it is concluded that the accumulating radiobiological and epidemiological evidence makes it more appropriate to treat cataract induction as a stochastic rather than a deterministic effect. Within this framework, it is illogical to have the same dose limit for the lens of the eye as for the whole body irradiated uniformly. This could be addressed either by removing the special dose limit for the lens of the eye, assigning it an appropriate tissue weighting factor and including it in the computation of the effective dose, or through a composite approach involving the use of a tissue weighting factor for effective dose computations together with a special limit on the equivalent dose to the lens of the eye to ensure that no individual was subject to an unacceptably high risk of induction of clinically significant cataracts.
Ibrahim, Shawki; Simon, Steven L; Bouville, André; Melo, Dunstana; Beck, Harold
2009-01-01
This paper presents gastrointestinal absorption fractions (f1 values) for estimating internal doses from local and regional fallout radionuclides due to nuclear tests. The choice of f1 values are based on specific circumstances of weapons test conditions and a review of reported f1 values for elements in different physical and chemical states. Special attention is given to fallout from nuclear tests conducted at the Marshall Islands. We make a distinction between the f1 values for intakes of radioactive materials immediately after deposition (acute intakes) and intakes that occur in the course of months and years after deposition, following incorporation into terrestrial and aquatic foodstuffs (chronic intakes). Multiple f1 values for different circumstances where persons are exposed to radioactive fallout (e.g. local vs. regional fallout and coral vs. continental tests) are presented when supportive information is available. In some cases, our selected f1 values are similar to those adopted by the ICRP (e.g. iodine and most actinides). However, f1 values for cesium and strontium derived from urine bioassay data of the Marshallese population are notably lower than the generic f1 values recommended by ICRP, particularly for acute intakes from local fallout (0.4 and 0.05 for Cs and Sr, respectively. The f1 values presented here form the first complete set of values relevant to realistic dose assessments for exposure to local or regional radioactive fallout. PMID:20622554
Ibrahim, Shawki A; Simon, Steven L; Bouville, André; Melo, Dunstana; Beck, Harold L
2010-08-01
This paper presents gastrointestinal absorption fractions (f1 values) for estimating internal doses from local and regional fallout radionuclides due to nuclear tests. The choice of f1 values are based on specific circumstances of weapons test conditions and a review of reported f1 values for elements in different physical and chemical states. Special attention is given to fallout from nuclear tests conducted at the Marshall Islands. We make a distinction between the f1 values for intakes of radioactive materials immediately after deposition (acute intakes) and intakes that occur in the course of months and years after deposition, following incorporation into terrestrial and aquatic foodstuffs (chronic intakes). Multiple f1 values for different circumstances where persons are exposed to radioactive fallout (e.g., local vs. regional fallout and coral vs. continental tests) are presented when supportive information is available. In some cases, our selected f1 values are similar to those adopted by the International Commission on Radiological Protection (ICRP) (e.g., iodine and most actinides). However, f1 values for cesium and strontium derived from urine bioassay data of the Marshallese population are notably lower than the generic f1 values recommended by ICRP, particularly for acute intakes from local fallout (0.4 and 0.05 for Cs and Sr, respectively). The f1 values presented here form the first complete set of values relevant to realistic dose assessments for exposure to local or regional radioactive fallout.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolch, W E; Eckerman, Keith F; Sgouros, George
2009-03-01
The internal dosimetry schema of the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine has provided a broad framework for assessment of the absorbed dose to whole organs, tissue subregions, voxelized tissue structures, and individual cellular compartments for use in both diagnostic and therapeutic nuclear medicine. The schema was originally published in 1968, revised in 1976, and republished in didactic form with comprehensive examples as the MIRD primer in 1988 and 1991. The International Commission on Radiological Protection (ICRP) is an organization that also supplies dosimetric models and technical data, for use in providing recommendations formore » limits on ionizing radiation exposure to workers and members of the general public. The ICRP has developed a dosimetry schema similar to that of the MIRD Committee but has used different terminology and symbols for fundamental quantities such as the absorbed fraction, specific absorbed fraction, and various dose coefficients. The MIRD Committee objectives for this pamphlet are 3-fold: to restate its schema for assessment of absorbed dose in a manner consistent with the needs of both the nuclear medicine and the radiation protection communities, with the goal of standardizing nomenclature; to formally adopt the dosimetry quantities equivalent dose and effective dose for use in comparative evaluations of potential risks of radiation-induced stochastic effects to patients after nuclear medicine procedures; and to discuss the need to identify dosimetry quantities based on absorbed dose that address deterministic effects relevant to targeted radionuclide therapy.« less
Priya, S; Srinivasan, P; Gopalakrishnan, R K
2012-01-01
The thoria dissolver, used for separation of (233)U from reactor-irradiated thorium metal and thorium oxide rods, is no longer operational. It was decided to carry out assessment of the radiological status of the dissolver cell for planning of the future decommissioning/dismantling operations. The dissolver interiors are expected to be contaminated with the dissolution remains of irradiated thorium oxide rods in addition to some of the partially dissolved thoria pellets. Hence, (220)Rn, a daughter product of (228)Th is of major radiological concern. Airborne activity of thoron daughters (212)Pb (Th-B) and (212)Bi (Th-C) was estimated by air sampling followed by high-resolution gamma spectrometry of filter papers. By measuring the full-energy peaks counts in the energy windows of (212)Pb, (212)Bi and (208)Tl, concentrations of thoron progeny in the sampled air were estimated by applying the respective intrinsic peak efficiency factors and suitable correction factors for the equilibration effects of (212)Pb and (212)Bi in the filter paper during the delay between sampling and counting. Then the thoron working level (TWL) was evaluated using the International Commission on Radiological Protection (ICRP) methodology. Finally, the potential effective dose to the workers, due to inhalation of thoron and its progeny during dismantling operations was assessed by using dose conversion factors recommended by ICRP. Analysis of filter papers showed a maximum airborne thoron progeny concentration of 30 TWLs inside the dissolver.
Slack, Catherine M.
2014-01-01
There has been debate about sponsor-investigator ethical responsibilities to address participants’ medical needs in trials in resource-constrained contexts. Certain ethical guidelines make detailed recommendations. This study explored whether ethical guideline recommendations for care in HIV vaccine trials were being met, and whether stakeholders were facing difficulties addressed by guidelines. It sampled key stakeholders involved in two trials across five sites in South Africa, and reviewed relevant documentation. It concluded that sites were largely meeting guideline recommendations for addressing needs, with some exceeding these. Recommendations for writing protocols were only partially achieved. Recommendations for engaging participating community were mostly met, except for “moral negotiation” recommendations. Suggestions are made to strengthen practices, and to improve guidelines so they address empirical concerns. PMID:24572086
Slack, Catherine M
2014-02-01
There has been debate about sponsor-investigator ethical responsibilities to address participants' medical needs in trials in resource-constrained contexts. Certain ethical guidelines make detailed recommendations. This study explored whether ethical guideline recommendations for care in HIV vaccine trials were being met, and whether stakeholders were facing difficulties addressed by guidelines. It sampled key stakeholders involved in two trials across five sites in South Africa, and reviewed relevant documentation. It concluded that sites were largely meeting guideline recommendations for addressing needs, with some exceeding these. Recommendations for writing protocols were only partially achieved. Recommendations for engaging participating community were mostly met, except for "moral negotiation" recommendations. Suggestions are made to strengthen practices, and to improve guidelines so they address empirical concerns.
Summer 1983 Leeway Drift Experiment.
1985-08-01
used as the basis for the SAR Manual’s recommendation ( Scobie and Thompson, 1979). The RFD raft was deflected to the right or left of the wind...a leeway study for undrogued, canopied life rafts ( Scobie and Thompson, 1979). The current was measured by a buoy equipped with a 10-foot (3 m...recommendation for the canopied rafts with deep-draft ballast systems is based on data using a buoy with a 10-foot (3-m) square window-shade drogue ( Scobie
75 FR 10759 - New England Fishery Management Council; Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-09
... Fishery Management Council; Public Meeting AGENCY: National Marine Fisheries Service (NMFS), National... exclusive economic zone (EEZ). Recommendations from this group will be brought to the full Council for... complex using updated survey data; review the Ecosystem-Based Fishery Management draft policy paper and...
Reading on the Job: Schema, Function, and Depth.
ERIC Educational Resources Information Center
Jordan, William A.
A study conducted at the Albuquerque Vocational-Technical Institute (New Mexico) investigated the need for occupation-related reading skills and resulted in recommendations for curriculum and instruction to meet those needs. The occupational areas examined include architectural drafting, office occupations, diesel mechanics, practical nursing,…
Citizen Education Today. Draft.
ERIC Educational Resources Information Center
National Center for Voluntary Action, Washington, DC.
The document views citizenship education from the perspectives of the past and present and offers recommendations for improving citizenship education programs. The document is presented in three chapters, preceeded by an introductory essay highlighting major developments in citizenship education in the United States since the colonial period.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarberry, Randy
This is for a Java World article that was already published on Nov 21, 2006. When I originally submitted the draft, Java World wasn't in the available lists of publications. Now that it is, Hanford Library staff recommended that I resubmit so it would be counted. Original submission ID: PNNL-SA-52490
Cardot, J-M; Garcia Arieta, A; Paixao, P; Tasevska, I; Davit, B
2016-07-01
The US-FDA recently posted a draft guideline for industry recommending procedures necessary to obtain a biowaiver for immediate-release oral dosage forms based on the Biopharmaceutics Classification System (BCS). This review compares the present FDA BCS biowaiver approach, with the existing European Medicines Agency (EMA) approach, with an emphasis on similarities, difficulties, and shared challenges. Some specifics of the current EMA BCS guideline are compared with those in the recently published draft US-FDA BCS guideline. In particular, similarities and differences in the EMA versus US-FDA approaches to establishing drug solubility, permeability, dissolution, and formulation suitability for BCS biowaiver are critically reviewed. Several case studies are presented to illustrate the (i) challenges of applying for BCS biowaivers for global registration in the face of differences in the EMA and US-FDA BCS biowaiver criteria, as well as (ii) challenges inherent in applying for BCS class I or III designation and common to both jurisdictions.
Consensus standards for introductory e-learning courses in human participants research ethics
Williams, John R; Sprumont, Dominique; Hirtle, Marie; Adebamowo, Clement; Braunschweiger, Paul; Bull, Susan; Burri, Christian; Czarkowski, Marek; Te Fan, Chien; Franck, Caroline; Gefenas, Eugenjius; Geissbuhler, Antoine; Klingmann, Ingrid; Kouyaté, Bocar; Kraehenbhul, Jean-Pierre; Kruger, Mariana; Moodley, Keymanthri; Ntoumi, Francine; Nyirenda, Thomas; Pym, Alexander; Silverman, Henry; Tenorio, Sara
2015-01-01
This paper reports the results of a workshop held in January 2013 to begin the process of establishing standards for e-learning programmes in the ethics of research involving human participants that could serve as the basis of their evaluation by individuals and groups who want to use, recommend or accredit such programmes. The standards that were drafted at the workshop cover the following topics: designer/provider qualifications, learning goals, learning objectives, content, methods, assessment of participants and assessment of the course. The authors invite comments on the draft standards and eventual endorsement of a final version by all stakeholders. PMID:23959838
Mars Sample Handling Protocol Workshop Series: Workshop 4
NASA Technical Reports Server (NTRS)
Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)
2001-01-01
In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol, which was compiled from deliberations and recommendations from earlier Workshops in the Series, represents a consensus that emerged from the discussions of all the sub-groups assembled over the course of the five Workshops of the Series. These discussions converged on a conceptual approach to sample handling, as well as on specific analytical requirements. Discussions also identified important issues requiring attention, as well as research and development needed for protocol implementation.
Hascoët, J-M; Petitprez, K
2014-09-01
In light of changes in both medical practices and the organization of medical care, the French National Authority for Health (Haute Autorité de santé, HAS) proposed new recommendations on the discharge of mothers and newborns, updating its 2004 recommendations on early discharge of mothers and newborns. This decision in turn made it necessary to define optimal discharge conditions and accompanying measures for mothers and infants returning home. The problem was approached by adopting the usual HAS methodology for drafting good practice recommendations. This involved establishing a working group bringing together representatives of all medical and care fields related to perinatology as well as patient representatives. This working group submitted draft recommendations, based on updated published references, to a committee. The committee then proposed amendments to the recommendations, which the working group was free to accept or reject. The updated recommendations that emerged from this process apply four essential principles : first, preparing for discharge as early as the prenatal period, ideally during the third trimester of pregnancy, in particular by providing expectant mothers with information on how the discharge will be organized and anticipating problems that might arise; second, ensuring care continuity between hospitalization, discharge to home, and follow-up; third, ensuring optimal conditions for discharge after a maternity stay of 72-96 h for normal delivery or 96-120 h in case of caesarean section (this hospital stay duration allows for neonatal screening); and fourth, defining how mothers and children are to be accompanied during the first postnatal month. In conclusion, these recommendations resulted in an increase in the duration of as well as an improvement in routine newborn surveillance, whether in hospital or after discharge, in what is a critical phase of infant development. They encourage ambulatory postnatal monitoring. The new recommendations ensure continuity of care while taking into account mothers' and couples' wish to take responsibility for organizing their own healthcare. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Meerpohl, Joerg J; Schell, Lisa K; Bassler, Dirk; Gallus, Silvano; Kleijnen, Jos; Kulig, Michael; La Vecchia, Carlo; Marušić, Ana; Ravaud, Philippe; Reis, Andreas; Schmucker, Christine; Strech, Daniel; Urrútia, Gerard; Antes, Gerd
2015-01-01
Background Dissemination bias in clinical research severely impedes informed decision-making not only for healthcare professionals and patients, but also for funders, research ethics committees, regulatory bodies and other stakeholder groups that make health-related decisions. Decisions based on incomplete and biased evidence cannot only harm people, but may also have huge financial implications by wasting resources on ineffective or harmful diagnostic and therapeutic measures, and unnecessary research. Owing to involvement of multiple stakeholders, it remains easy for any single group to assign responsibility for resolving the problem to others. Objective To develop evidence-informed general and targeted recommendations addressing the various stakeholders involved in knowledge generation and dissemination to help overcome the problem of dissemination bias on the basis of previously collated evidence. Methods Based on findings from systematic reviews, document analyses and surveys, we developed general and targeted draft recommendations. During a 2-day workshop in summer 2013, these draft recommendations were discussed with external experts and key stakeholders, and refined following a rigorous and transparent methodological approach. Results Four general, overarching recommendations applicable to all or most stakeholder groups were formulated, addressing (1) awareness raising, (2) implementation of targeted recommendations, (3) trial registration and results posting, and (4) systematic approaches to evidence synthesis. These general recommendations are complemented and specified by 47 targeted recommendations tailored towards funding agencies, pharmaceutical and device companies, research institutions, researchers (systematic reviewers and trialists), research ethics committees, trial registries, journal editors and publishers, regulatory agencies, benefit (health technology) assessment institutions and legislators. Conclusions Despite various recent examples of dissemination bias and several initiatives to reduce it, the problem of dissemination bias has not been resolved. Tailored recommendations based on a comprehensive approach will hopefully help increase transparency in biomedical research by overcoming the failure to disseminate negative findings. PMID:25943371
76 FR 44602 - State of Arizona Resource Advisory Council Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
... Mineral Withdrawal Draft Environmental Impact Statement; presentation and RAC recommendations on the Red Rock Pass Program; RAC questions on District Managers' Reports; reports by the RAC working groups; and... Forest Service recreation fee proposals in Arizona. The RRAC will review the Forest Service's Red Rock...
ERIC Educational Resources Information Center
Johnson, Robert
1987-01-01
Describes a teacher's presentation in the classroom of the drafts, notes, outlines, and other artifacts from his own papers. Recommends that teachers show their students evidence of their own struggle with the writing process in order to encourage them and convince them that all writers hesitatingly begin with a mess. (JG)
75 FR 31424 - New England Fishery Management Council; Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-03
... Fishery Management Council; Public Meeting AGENCY: National Marine Fisheries Service (NMFS), National... economic zone (EEZ). Recommendations from this group will be brought to the full Council for formal.... Tuesday, June 22, 2010 The SSC will review the Ecosystem-Based Fishery Management draft policy paper...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0584... Products.'' This guidance updates recommendations regarding degradation products and updates the draft... information on listing of degradation products, setting acceptance criteria, and qualifying degradation...
A Guide for Equipping Industrial Arts Facilities.
ERIC Educational Resources Information Center
American Industrial Arts Association, Washington, DC. Equipment Guide Committee.
A guide for planning new and revising existing industrial arts facilities which gives a listing of tools and equipment recommended for each of the major areas of instruction (automotive and power mechanics, ceramics, drafting, electronics, elementary, general shop, graphic arts, metalworking, plastics, and woodworking). General descriptions and…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-20
.... The Report: Characterized marbled murrelet ecology and life history, recommended landscape... of their proposed actions to determine if the actions may significantly affect the human environment... on marbled murrelets and other species, and their communities and habitats; Marbled murrelet ecology...
78 FR 19691 - Defense Business Board; Notice of Federal Advisory Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... draft recommendations from the ``Applying Best Business Practices for Corporate Performance Management...: ``Applying Best Business Practices for Corporate Performance Management to DoD,'' ``Major Business Issues for... Group Study and ``Using Best Practices to Achieve More Effective Participation by Industry'' Task Group...
INSTRUMENTATION AND CONTROLS DIVISION ELECTRICAL DESIGN STANDARDS AND GRAPHICAL SYMBOLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1961-11-01
Copies are presented of the American Standards Association graphical symbols for electrical and electronic equipment and systems. Recommendations are given for electrical elementary design layout, device codings, etc., for permanent type installations. Electrical diagrams copied from American Drafting Standards Manual are presented. (M.C.G.)
7 CFR 1942.5 - Application review and approval.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Public Law 103-354 by written amendment to this letter. Any changes not approved by FmHA or its successor... Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS... complete the project summary, including written analysis and recommendations, and will prepare a draft...
Employing Our Veterans. Part 2. Service Member Transition
2013-01-01
Chamber of Commerce and the organization’s work to educate the American employer on the benefits and value of hiring veterans. The Task Group also spent time with both local and national veterans outreach programs to understand the demographics and data surrounding the issues. The Task Group’s draft findings and recommendations were presented to the Board for deliberation at the January 24, 2013 quarterly meeting where the Board voted to approve the recommendations. See Tab B for a copy of the brief including the final
Katja — the 24th week of virtual pregnancy for dosimetric calculations
NASA Astrophysics Data System (ADS)
Becker, Janine; Zankl, Maria; Fill, Ute; Hoeschen, Christoph
2008-01-01
Virtual human models, a.k.a. voxel models, are currently the
Sacks, David B; Arnold, Mark; Bakris, George L; Bruns, David E; Horvath, Andrea Rita; Kirkman, M Sue; Lernmark, Ake; Metzger, Boyd E; Nathan, David M
2011-06-01
Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A(1c) (HbA(1c)) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of HbA(1c). The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended.
Sacks, David B; Arnold, Mark; Bakris, George L; Bruns, David E; Horvath, Andrea Rita; Kirkman, M Sue; Lernmark, Ake; Metzger, Boyd E; Nathan, David M
2011-06-01
Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence Based Laboratory Medicine Committee of the AACC jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A(1c) (Hb A(1c)) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of Hb A(1c). The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended.
Peter, W F; Jansen, M J; Hurkmans, E J; Bloo, H; Dekker, J; Dilling, R G; Hilberdink, W; Kersten-Smit, C; de Rooij, M; Veenhof, C; Vermeulen, H M; de Vos, R J; Schoones, J W; Vliet Vlieland, T P
2011-01-01
An update of a Dutch physiotherapy practice guideline in Hip and Knee Osteoarthritis (HKOA) was made, based on current evidence and best practice. A guideline steering committee, comprising 10 expert physiotherapists, selected topics concerning the guideline chapters: initial assessment, treatment and evaluation. With respect to treatment a systematic literature search was performed using various databases, and the evidence was graded (1-4). For the initial assessment and evaluation mainly review papers and textbooks were used. Based on evidence and expert opinion, recommendations were formulated. A first draft of the guideline was reviewed by 17 experts from different professional backgrounds. A second draft was field-tested by 45 physiotherapists. In total 11 topics were selected. For the initial assessment, three recommendations were formulated, pertaining to history taking, red flags, and formulating treatment goals. Concerning treatment, 7 recommendations were formulated; (supervised) exercise therapy, education and self management interventions, a combination of exercise and manual therapy, postoperative exercise therapy and taping of the patella were recommended. Balneotherapy and hydrotherapy in HKOA, and thermotherapy, TENS, and Continuous Passive Motion in knee OA were neither recommended nor discouraged. Massage therapy, ultrasound, electrotherapy, electromagnetic field, Low Level Laser Therapy, preoperative physiotherapy and education could not be recommended. For the evaluation of treatment goals the following measurement instruments were recommended: Lequesne index, Western Ontario and McMaster Universities osteoarthritis index, Hip disability and Osteoarthritis Outcome Score and Knee injury and Osteoarthritis Outcome Score, 6-minute walktest, Timed Up and Go test, Patient Specific Complaint list, Visual Analoge Scale for pain, Intermittent and Constant OsteoArthritis Pain Questionnaire, goniometry, Medical Research Council for strength, handheld dynamometer. This update of a Dutch physiotherapy practice guideline on HKOA included 11 recommendations on the initial assessment, treatment and evaluation. The implementation of the guideline in clinical practice needs further evaluation.
77 FR 29595 - New England Fishery Management Council; Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
... group will be brought to the full Council for formal consideration and action, if appropriate. DATES...). Updated boundary recommendations from the PDT were discussed at the April Committee meeting, but decision-making was deferred. Second, the Committee will consider (1) a draft Memorandum of Understanding with the...
77 FR 17459 - Pacific Fishery Management Council (Pacific Council); Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-26
... meeting. SUMMARY: The Pacific Council will convene a meeting of the Ecosystem Plan Development Team (EPDT... drafting a report and recommendations to the Council on the Development of a Fishery Ecosystem Plan (FEP... Council meeting, revise and expand sections of the Council's developing Fishery Ecosystem Plan, discuss...
77 FR 30509 - Fiscal Year 2012 Draft Work Plan
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-23
... determines its own basic operating principles and funding criteria on an annual federal fiscal year (October 1 to September 30) basis. The Commission outlines these priorities and funding recommendations in an... federal funding sources (identified by the varying colors in the table below). These fund sources are...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-02
... international harmonization (e) Making recommendations for information exchange in relation to food import...;and investigations, committee meetings, agency decisions and rulings, #0;delegations of authority... to provide information and receive public comments on agenda items and draft United States (U.S...
Student Success: The Case for Establishing Prerequisites through Content Review
ERIC Educational Resources Information Center
Academic Senate for California Community Colleges, 2010
2010-01-01
In the 1990s, the Academic Senate collaborated with the Chancellor's Office and other leadership groups in the state to revise Title 5 regulations, to draft "The Model District Policy on Prerequisites, Corequisites, and Advisories on Recommended Preparation" (Board of Governors, 1993) and "Prerequisites, Corequisites, Advisories, And Limitations…
77 FR 60478 - Proposal Review Panel for Computing Communication Foundations; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... assess the progress of the EIC Award: 1029711, ``Collaborative Research: Mining Climate and Ecosystem Data'', and to provide advice and recommendations concerning further NSF support for the Center. AGENDA... answer sessions. 1 p.m.-8 p.m. Closed Draft report on education and research activities. Wednesday...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... provides recommendations for the design of clinical trials for cancer vaccines conducted under an IND to... in this notice finalizes the draft guidance of the same title dated September 2009. DATES: Submit...), Center for Biologics Evaluation and Research (CBER), Food and Drug Administration, 1401 Rockville Pike...
Building New Educational Strategies to Serve Rural Children and Youth.
ERIC Educational Resources Information Center
Coombs, Philip H.; Ahmed, Manzoor
Summarizing the International Council for Educational Development's (ICED) second report on the study of nonformal education for rural youth and children, this draft of the second report outlines the substance of each chapter and the main findings, conclusions, and recommendations. This summary does not include the detailed evidence,…
18 CFR 5.16 - Preliminary licensing proposal.
Code of Federal Regulations, 2011 CFR
2011-04-01
... its studies conducted under the approved study plan. (c) A potential applicant may elect to file a... application must include notice of its intent to do so in the updated study report required by § 5.15(f). (d... draft application, which may include recommendations on whether the Commission should prepare an...
IRIS Toxicological Review of Hexavalent Chromium (2010 External Review Draft)
Guidelines for dynamic data acquisition and analysis
NASA Technical Reports Server (NTRS)
Piersol, Allan G.
1992-01-01
The recommendations concerning pyroshock data presented in the final draft of a proposed military handbook on Guidelines for Dynamic Data Acquisition and Analysis are reviewed. The structural responses produced by pyroshocks are considered to be one of the most difficult types of dynamic data to accurately measure and analyze.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
..., identifying significant environmental issues in the DEIS/EIR, providing useful information such as published and unpublished data, and knowledge of relevant issues and recommending mitigation measures to offset... the scoping process. c. Individuals and agencies may offer information or data relevant to the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, J.S.; Abrahmson, S.; Bender, M.A.
1993-10-01
This report is a revision of NUREG/CR-4214, Rev. 1, Part 1 (1990), Health Effects Models for Nuclear Power Plant Accident Consequence Analysis. This revision has been made to incorporate changes to the Health Effects Models recommended in two addenda to the NUREG/CR-4214, Rev. 1, Part 11, 1989 report. The first of these addenda provided recommended changes to the health effects models for low-LET radiations based on recent reports from UNSCEAR, ICRP and NAS/NRC (BEIR V). The second addendum presented changes needed to incorporate alpha-emitting radionuclides into the accident exposure source term. As in the earlier version of this report, modelsmore » are provided for early and continuing effects, cancers and thyroid nodules, and genetic effects. Weibull dose-response functions are recommended for evaluating the risks of early and continuing health effects. Three potentially lethal early effects -- the hematopoietic, pulmonary, and gastrointestinal syndromes are considered. Linear and linear-quadratic models are recommended for estimating the risks of seven types of cancer in adults - leukemia, bone, lung, breast, gastrointestinal, thyroid, and ``other``. For most cancers, both incidence and mortality are addressed. Five classes of genetic diseases -- dominant, x-linked, aneuploidy, unbalanced translocations, and multifactorial diseases are also considered. Data are provided that should enable analysts to consider the timing and severity of each type of health risk.« less
Pragmatic ethical basis for radiation protection in diagnostic radiology.
Malone, Jim; Zölzer, Friedo
2016-01-01
Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years. The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations. A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic imaging. This system has the potential to be robust and to reach conclusions that are in accord with contemporary medical, social and ethical thinking. The system is not intended to replace the ICRP principles. Rather, it is intended as a well-informed interim approach that will help judge and analyse situations that arouse ethical concerns in radiology. Six scenarios illustrate the practicality of the value system in alerting one to possible deficits in practice. Five widely recognized values and the basis for them are identified to support the contemporary practice of diagnostic radiology. These are essential to complement the widely used ICRP principles pending further development in the area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McLaughlin, David A
Derived air concentration (DAC) values for 175 radionuclides* produced at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), but not listed in Appendix A of 10 CFR 835 (01/01/2009 version), are presented. The proposed DAC values, ranging between 1 E-07 {micro}Ci/mL and 2 E-03 {micro}Ci/mL, were calculated in accordance with the recommendations of the International Commission on Radiological Protection (ICRP), and are intended to support an exemption request seeking regulatory relief from the 10 CFR 835, Appendix A, requirement to apply restrictive DACs of 2E-13 {micro}Ci/mL and 4E-11 {micro}Ci/mL and for non-listed alpha and non-alpha-emitting radionuclides, respectively.
NASA Astrophysics Data System (ADS)
Grupen, Claus
Radiation protection is a very important aspect for the application of particle detectors in many different fields, like high energy physics, medicine, materials science, oil and mineral exploration, and arts, to name a few. The knowledge of radiation units, the experience with shielding, and information on biological effects of radiation are vital for scientists handling radioactive sources or operating accelerators or X-ray equipment. This article describes the modern radiation units and their conversions to older units which are still in use in many countries. Typical radiation sources and detectors used in the field of radiation protection are presented. The legal regulations in nearly all countries follow closely the recommendations of the International Commission on Radiological Protection (ICRP). Tables and diagrams with relevant information on the handling of radiation sources provide useful data for the researcher working in this field.
The potential clinical impact of the release of two drafts of the human proteome
Ezkurdia, Iakes; Calvo, Enrique; Del Pozo, Angela; Vázquez, Jesús; Valencia, Alfonso; Tress, Michael L.
2015-01-01
The authors have carried out an investigation of the two “draft maps of the human proteome” published in 2014 in Nature. The findings include an abundance of poor spectra, low-scoring peptide-spectrum matches and incorrectly identified proteins in both these studies, highlighting clear issues with the application of false discovery rates. This noise means that the claims made by the two papers – the identification of high numbers of protein coding genes, the detection of novel coding regions and the draft tissue maps themselves – should be treated with considerable caution. The authors recommend that clinicians and researchers do not use the unfiltered data from these studies. Despite this these studies will inspire further investigation into tissue-based proteomics. As long as this future work has proper quality controls, it could help produce a consensus map of the human proteome and improve our understanding of the processes that underlie health and disease. PMID:26496066
Siegfried, Elaine C; Jaworski, Jennifer C; Eichenfield, Lawrence F; Paller, Amy; Hebert, Adelaide A; Simpson, Eric L; Altman, Emily; Arena, Charles; Blauvelt, Andrew; Block, Julie; Boguniewicz, Mark; Chen, Suephy; Cordoro, Kelly; Hanna, Diane; Horii, Kimberly; Hultsch, Thomas; Lee, James; Leung, Donald Y; Lio, Peter; Milner, Joshua; Omachi, Theodore; Schneider, Christine; Schneider, Lynda; Sidbury, Robert; Smith, Timothy; Sugarman, Jeffrey; Taha, Sharif; Tofte, Susan; Tollefson, Megha; Tom, Wynnis L; West, Dennis P; Whitney, Lucinda; Zane, Lee
2018-05-01
Atopic dermatitis is the most common chronic skin disease, and it primarily affects children. Although atopic dermatitis (AD) has the highest effect on burden of skin disease, no high-level studies have defined optimal therapy for severe disease. Corticosteroids have been used to treat AD since the 1950s and remain the only systemic medication with Food and Drug Administration approval for this indication in children, despite published guidelines of care that recommend against this option. Several clinical trials with level 1 evidence have supported the use of topical treatments for mild to moderate atopic dermatitis in adults and children, but these trials have had little consistency in protocol design. Consensus recommendations will help standardize clinical development and trial design for children. The Food and Drug Administration issues guidance documents for industry as a source for "the Agency's current thinking on a particular subject." Although they are nonbinding, industry considers these documents to be the standard for clinical development and trial design. Our consensus group is the first to specifically address clinical trial design in this population. We developed a draft guidance document for industry, Developing Drugs for Treatment of Atopic Dermatitis in Children (≥3 months to <18 years of age). This draft guidance has been submitted to the Food and Drug Administration based on a provision in the Federal Register (Good Guidance Practices). © 2018 Wiley Periodicals, Inc.
Barratt, Christopher L R; Björndahl, Lars; De Jonge, Christopher J; Lamb, Dolores J; Osorio Martini, Francisco; McLachlan, Robert; Oates, Robert D; van der Poel, Sheryl; St John, Bianca; Sigman, Mark; Sokol, Rebecca; Tournaye, Herman
2017-11-01
Herein, we describe the consensus guideline methodology, summarize the evidence-based recommendations we provided to the World Health Organization (WHO) for their consideration in the development of global guidance and present a narrative review of the diagnosis of male infertility as related to the eight prioritized (problem or population (P), intervention (I), comparison (C) and outcome(s) (O) (PICO)) questions. Additionally, we discuss the challenges and research gaps identified during the synthesis of this evidence. The aim of this paper is to present an evidence-based approach for the diagnosis of male infertility as related to the eight prioritized PICO questions. Collating the evidence to support providing recommendations involved a collaborative process as developed by WHO, namely: identification of priority questions and critical outcomes; retrieval of up-to-date evidence and existing guidelines; assessment and synthesis of the evidence; and the formulation of draft recommendations to be used for reaching consensus with a wide range of global stakeholders. For each draft recommendation the quality of the supporting evidence was then graded and assessed for consideration during a WHO consensus. Evidence was synthesized and recommendations were drafted to address the diagnosis of male infertility specifically encompassing the following: What is the prevalence of male infertility and what proportion of infertility is attributable to the male? Is it necessary for all infertile men to undergo a thorough evaluation? What is the clinical (ART/non ART) value of traditional semen parameters? What key male lifestyle factors impact on fertility (focusing on obesity, heat and tobacco smoking)? Do supplementary oral antioxidants or herbal therapies significantly influence fertility outcomes for infertile men? What are the evidence-based criteria for genetic screening of infertile men? How does a history of neoplasia and related treatments in the male impact on (his and his partner's) reproductive health and fertility options? And lastly, what is the impact of varicocele on male fertility and does correction of varicocele improve semen parameters and/or fertility? This evidence synthesis analysis has been conducted in a manner to be considered for global applicability for the diagnosis of male infertility. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology.
Barratt, Christopher L R; Björndahl, Lars; De Jonge, Christopher J; Lamb, Dolores J; Osorio Martini, Francisco; McLachlan, Robert; Oates, Robert D; van der Poel, Sheryl; St John, Bianca; Sigman, Mark; Sokol, Rebecca; Tournaye, Herman
2017-01-01
Abstract BACKGROUND Herein, we describe the consensus guideline methodology, summarize the evidence-based recommendations we provided to the World Health Organization (WHO) for their consideration in the development of global guidance and present a narrative review of the diagnosis of male infertility as related to the eight prioritized (problem or population (P), intervention (I), comparison (C) and outcome(s) (O) (PICO)) questions. Additionally, we discuss the challenges and research gaps identified during the synthesis of this evidence. OBJECTIVE AND RATIONALE The aim of this paper is to present an evidence-based approach for the diagnosis of male infertility as related to the eight prioritized PICO questions. SEARCH METHODS Collating the evidence to support providing recommendations involved a collaborative process as developed by WHO, namely: identification of priority questions and critical outcomes; retrieval of up-to-date evidence and existing guidelines; assessment and synthesis of the evidence; and the formulation of draft recommendations to be used for reaching consensus with a wide range of global stakeholders. For each draft recommendation the quality of the supporting evidence was then graded and assessed for consideration during a WHO consensus. OUTCOMES Evidence was synthesized and recommendations were drafted to address the diagnosis of male infertility specifically encompassing the following: What is the prevalence of male infertility and what proportion of infertility is attributable to the male? Is it necessary for all infertile men to undergo a thorough evaluation? What is the clinical (ART/non ART) value of traditional semen parameters? What key male lifestyle factors impact on fertility (focusing on obesity, heat and tobacco smoking)? Do supplementary oral antioxidants or herbal therapies significantly influence fertility outcomes for infertile men? What are the evidence-based criteria for genetic screening of infertile men? How does a history of neoplasia and related treatments in the male impact on (his and his partner's) reproductive health and fertility options? And lastly, what is the impact of varicocele on male fertility and does correction of varicocele improve semen parameters and/or fertility? WIDER IMPLICATIONS This evidence synthesis analysis has been conducted in a manner to be considered for global applicability for the diagnosis of male infertility. PMID:28981651
Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J
2017-03-01
The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.
Overview of ICRP Committee 5: protection of the environment.
Larsson, C-M
2016-06-01
Protection of the environment is integral to the system of radiological protection, as outlined in the 2007 Recommendations of the International Commission on Radiological Protection (ICRP, Publication 103). The Commission's activities in this area are mainly pursued by Committee 5 and its associated Task Groups. Publication 91 broadly outlines the approach to radiological protection of the environment, and its alignment with approaches to environmental protection from hazardous substances in general. Publications 108 and 114 provide the cornerstones of the environmental protection system and relevant databases. Publication 124 considers its application in planned, existing, and emergency exposure situations. The system centres on 12 Reference Animals and Plants (RAPs) with broad relevance for environmental protection based on their ubiquity and significance as well as other criteria, as described in Publication 108 The databases comprise general biology of the RAPs, transfer parameters, dose conversion coefficients, and effects data. Derived Consideration Reference Levels (DCRLs) were established for each RAP; a DCRL represents a band of dose rates that might result in some deleterious effects in individuals of that type of RAP. Newly established Task Group 99 will compile the RAP-specific reference information into monographs, with the view of updating information and improving the applicability of the system in different exposure situations. For certain scenarios, more precise and ecosystem-specific protection benchmarks may be justified, which would have to be informed by consideration of representative organisms (i.e. representative of a particular ecosystem and relevant to the specific scenario; Publication 124). Committee 5 will explore this further, making use of a limited number of case studies. © The International Society for Prosthetics and Orthotics.
USGEO DMWG Cloud Computing Recommendations
NASA Astrophysics Data System (ADS)
de la Beaujardiere, J.; McInerney, M.; Frame, M. T.; Summers, C.
2017-12-01
The US Group on Earth Observations (USGEO) Data Management Working Group (DMWG) has been developing Cloud Computing Recommendations for Earth Observations. This inter-agency report is currently in draft form; DMWG hopes to have released the report as a public Request for Information (RFI) by the time of AGU. The recommendations are geared toward organizations that have already decided to use the Cloud for some of their activities (i.e., the focus is not on "why you should use the Cloud," but rather "If you plan to use the Cloud, consider these suggestions.") The report comprises Introductory Material, including Definitions, Potential Cloud Benefits, and Potential Cloud Disadvantages, followed by Recommendations in several areas: Assessing When to Use the Cloud, Transferring Data to the Cloud, Data and Metadata Contents, Developing Applications in the Cloud, Cost Minimization, Security Considerations, Monitoring and Metrics, Agency Support, and Earth Observations-specific recommendations. This talk will summarize the recommendations and invite comment on the RFI.
75 FR 31761 - Agenda and Notice of Public Meeting of the Connecticut Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-04
... Connecticut, School of Law, Faculty Lounge, 55 Elizabeth Street, Hartford, Connecticut 06105. The purpose of the meeting is to consider possible findings and recommendations on a draft report about school choice, high school attainment rates, and civil rights. Members of the public are entitled to submit written...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... with a wide range of experts in state and Federal governments, academic institutions, and industry and... measures and performance-based standards recommended in the Safety Measures Report will be analyzed for... government, academic institutions, and industry and advocacy organizations. In addition, draft...
Draft Cognitive Skills Training Program for En-Route Air Traffic Controllers.
ERIC Educational Resources Information Center
Redding, Richard E.
This document begins with a discussion of the cognitive task analysis (CTA) that was commissioned by the Federal Aviation Administration to identify the cognitive skills-related training needs of en-route air traffic controllers. Concluding the introductory section are a brief list of recommendations regarding the design of a training program…
Alaska Statewide Plan for Postsecondary Education, 1986-1990: A Draft for Public Comment. Volume I.
ERIC Educational Resources Information Center
Alaska State Commission on Postsecondary Education, Juneau.
This report, the first statewide master plan for postsecondary education in Alaska, outlines strategies and recommendations to achieve the following planning goals: (1) promote excellence to improve educational service; (2) enhance accountability of the educational process; (3) foster efficiency within the enterprise; and (4) improve access to…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-08
... has been proposed by these two agencies to address emergency planning and preparedness for Nuclear..., to measure the adequacy of emergency preparedness plans of Nuclear Power Plant (NPP) owners and... changes proposed in FEMA's draft Radiological Emergency Preparedness Program Manual and Supplement 4 to...
ERIC Educational Resources Information Center
Vosko, Leah F.
2008-01-01
This article explores the transnational regulation of temporary work. Analyzing the terms of the EU "Directive on Fixed-Term Work (1999), the ILO "Convention on Private Employment Agencies" (1997), the ILO "Recommendation on the Employment Relationship" (2006), and a draft EU Directive on "Temporary Agency Work"…
DOT National Transportation Integrated Search
2010-05-01
This report presents the regional conformity analysis and recommendation for a finding : of conformity for the Hampton Roads 2030 Long Range Transportation Plan (LRTP, or : "Plan") and associated Fiscal Year (FY) 2009-2012 Transportation Improvement ...
76 FR 58332 - Announcement of Meeting of the International Telecommunication Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... the U.S. should agree that Study Group 15's draft new Recommendation G.tp-oam (Operations, Administration and Maintenance mechanism for MPLS-TP in Packet Transport Network (PTN)) should be considered for approval at the December Study Group meeting, (b) the policy that the U.S. should invoke during the...
Report #13-P-0057, November 27, 2012. EPA has taken a number of actions to address findings and recommendations from the OIG’s 2008 report, including developing the GAP Online database, drafting a GAP guidebook, and revising GAP guidance.
3 CFR 13508 - Executive Order 13508 of May 12, 2009. Chesapeake Bay Protection and Restoration
Code of Federal Regulations, 2010 CFR
2010-01-01
... of the Nation's largest estuarine ecosystem and the natural sustainability of its watershed, it is... be officers of the United States. Sec. 202. Reports on Key Challenges to Protecting and Restoring the... lead agencies shall prepare and submit draft reports to the Committee making recommendations for...
77 FR 39446 - Draft Parachute Landing Area Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-03
... part 139) to comply with new PLA Standards set forth in Change 19 to AC 150/5300-13, ``Airport Design,'' which address hazards, PLA size and location, and recommended markings. The FAA proposes to use these... safely and efficiently. The PLA Standards will apply at the time airports enter into new grant agreements...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... impacts of climate change upon the United States; and to provide advice and recommendations toward the... to produce a proposed National Climate Assessment that meets the requirements of the Global Change... Report Chapters: Our Changing Climate; Water Resources; Energy Supply and Use; Transportation...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-25
..., medical surveillance, and personal protective equipment; 6. Oral comments provided to NIOSH on the draft... where individuals sign up to make public comments. If individuals in making a statement reveal personal..., including any personal information provided. CONTACT PERSON FOR MORE INFORMATION: Lauralynn Taylor McKernan...
AAIDD Proposed Recommendations for "ICD-11" and the Condition Previously Known as Mental Retardation
ERIC Educational Resources Information Center
Tasse, Marc J.; Luckasson, Ruth; Nygren, Margaret
2013-01-01
The World Health Organization (WHO) is in the process of seeking input from professional stakeholder groups and consumers regarding the draft proposals of the 11th edition of the "International Classification of Diseases" ("ICD-11"). The American Association on Intellectual and Developmental Disabilities (AAIDD) convened a small group of…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
... systemic exposure measures is suitable for documenting BE. The guidance will be especially useful when..., delayed) release drug products, and to non-orally administered drug products in which reliance on systemic... revises recommendations related to (1) the use of systemic exposure measures and (2) considerations for...
A Plan to the Future in Home Economics Education. Draft Curriculum.
ERIC Educational Resources Information Center
Ruckes, Nina Tiglio; Mongillo, Michael
This curriculum guide was prepared to help Connecticut high schools offer an opportunity to disadvantaged high school students who are interested in home economics education to earn some college credit toward a degree in dietetic technology. The curriculum guide includes an overview of the course with a course description, recommended textbooks,…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-12
... the Science Advisor announces that Versar, Inc., a contractor to the EPA, will convene an independent...: Julie Fitzpatrick, Office of the Science Advisor, Mail Code 8105-R, U.S. Environmental Protection Agency... recommendations presented in the National Research Council's report Science and Decisions: Advancing Risk...
Payment to Creators for Library Loans (Public Lending Right).
ERIC Educational Resources Information Center
Faulds, M.
These recommendations and report on Public Lending Right (PLR) drafted by the Parliamentary Assembly of the Council of Europe were designed to encourage the recognition of the principle of PLR and the setting up of compatible PLR schemes throughout Europe. It discusses why an agreement for PLR is necessary, and describes several methods of…
DOT National Transportation Integrated Search
2010-05-01
This report presents the regional conformity analysis and recommendation for a finding of conformity for the Hampton Roads 2030 Long Range Transportation Plan (LRTP, or "Plan") and associated Fiscal Year (FY) 2009-2012 Transportation Improvement Prog...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... Institute for Occupational Safety and Health (NIOSH) of the Centers for Disease Control and Prevention (CDC...: The National Institute for Occupational Safety and Health (NIOSH) of the Centers for Disease Control..., Director, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention...
"A Date Which Will Live in Infamy": The First Typed Draft of Franklin D. Roosevelt's War Address.
ERIC Educational Resources Information Center
Schamel, Wynell Burroughs; West, Jean
1991-01-01
Presents suggestions for teaching activities and student projects using Franklin Roosevelt's war address following the Japanese attack on Pearl Harbor. Recommends vocabulary emphasis, class discussion, and classroom listening to a recording of the speech. Suggests comparing the speech to Patrick Henry's famous speech and interviewing individuals…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-27
.... In August 2010, the Center for Devices and Radiological Health (CDRH) published two documents in.... These documents are titled ``CDRH Preliminary Internal Evaluations--Volume I: 510(k) Working Group Preliminary Report and Recommendations'' and ``CDRH Preliminary Internal Evaluations--Volume II: Task Force on...
Callen, J; McKenna, T
2018-05-01
During the response to the Fukushima Daiichi nuclear power plant (FDNPP) emergency, about 50 patients died during or shortly after an evacuation when they were not provided with the needed medical support. In addition, it has been shown that during the FDNPP emergency there were increases in mortality rates among the elderly due to long-term dislocation as a result of evacuation and relocation orders and an inability to stay in areas where residents were advised to shelter for extended periods. These deaths occurred even though the possible radiation exposure to the public was too low to result in radiation-induced deaths, injuries, or a meaningful increase in the cancer rate, even if no protective actions had been taken. These problems are not unique to the FDNPP emergency and would be expected if the recommendations of many organizations were followed. Neither the International Commission on Radiological Protection (ICRP), the U.S. Nuclear Regulatory Commission (NRC) nor the U.S Environmental Protection Agency (EPA) adequately take into consideration in their recommendations and analysis the non-radiological health impacts, such as deaths and injuries, that could result from protective actions. Furthermore, ICRP, NRC, EPA, and the U.S. Department of Homeland Security (DHS) call for taking protective actions at doses lower than those resulting in meaningful adverse radiation-induced health effects and do not state the doses at which such effects would be seen. Consequently, it would be impossible for decision makers and the public to balance all the hazards both from radiation exposure and protective actions when deciding whether a protective action is justified. What is needed, as is presented in this paper, is a method for developing a comprehensive protective action strategy that allows the public, decision makers, and others who must work together to balance the radiological with the non-radiological health hazards posed by protective actions, and to counter the exaggerated fear of radiation exposure that could lead to taking unjustified protective actions and adverse psychological, sociological, and other effects.
Arnold, Mark; Bakris, George L.; Bruns, David E.; Horvath, Andrea Rita; Kirkman, M. Sue; Lernmark, Ake; Metzger, Boyd E.; Nathan, David M.
2011-01-01
BACKGROUND Multiple laboratory tests are used to diagnose and manage patients with diabetes mellitus. The quality of the scientific evidence supporting the use of these tests varies substantially. APPROACH An expert committee compiled evidence-based recommendations for the use of laboratory testing for patients with diabetes. A new system was developed to grade the overall quality of the evidence and the strength of the recommendations. Draft guidelines were posted on the Internet and presented at the 2007 Arnold O. Beckman Conference. The document was modified in response to oral and written comments, and a revised draft was posted in 2010 and again modified in response to written comments. The National Academy of Clinical Biochemistry and the Evidence-Based Laboratory Medicine Committee of the American Association for Clinical Chemistry jointly reviewed the guidelines, which were accepted after revisions by the Professional Practice Committee and subsequently approved by the Executive Committee of the American Diabetes Association. CONTENT In addition to long-standing criteria based on measurement of plasma glucose, diabetes can be diagnosed by demonstrating increased blood hemoglobin A1c (HbA1c) concentrations. Monitoring of glycemic control is performed by self-monitoring of plasma or blood glucose with meters and by laboratory analysis of HbA1c. The potential roles of noninvasive glucose monitoring, genetic testing, and measurement of autoantibodies, urine albumin, insulin, proinsulin, C-peptide, and other analytes are addressed. SUMMARY The guidelines provide specific recommendations that are based on published data or derived from expert consensus. Several analytes have minimal clinical value at present, and their measurement is not recommended. PMID:21617108
Doses and risks from the ingestion of Dounreay fuel fragments.
Darley, P J; Charles, M W; Fell, T P; Harrison, J D
2003-01-01
The radiological implications of ingestion of nuclear fuel fragments present in the marine environment around Dounreay have been reassessed by using the Monte Carlo code MCNP to obtain improved estimates of the doses to target cells in the walls of the lower large intestine resulting from the passage of a fragment. The approach takes account of the reduction in dose due to attenuation within the intestinal wall and self-absorption of radiation in the fuel fragment itself. In addition, dose is calculated on the basis of a realistic estimate of the anatomical volume of the lumen, rather than being based on the average mass of the contents, as in the current ICRP model. Our best estimates of doses from the ingestion of the largest Dounreay particles are at least a factor of 30 lower than those predicted using the current ICRP model. The new ICRP model will address the issues raised here and provide improved estimates of dose.
Meerpohl, Joerg J; Schell, Lisa K; Bassler, Dirk; Gallus, Silvano; Kleijnen, Jos; Kulig, Michael; La Vecchia, Carlo; Marušić, Ana; Ravaud, Philippe; Reis, Andreas; Schmucker, Christine; Strech, Daniel; Urrútia, Gerard; Wager, Elizabeth; Antes, Gerd
2015-05-05
Dissemination bias in clinical research severely impedes informed decision-making not only for healthcare professionals and patients, but also for funders, research ethics committees, regulatory bodies and other stakeholder groups that make health-related decisions. Decisions based on incomplete and biased evidence cannot only harm people, but may also have huge financial implications by wasting resources on ineffective or harmful diagnostic and therapeutic measures, and unnecessary research. Owing to involvement of multiple stakeholders, it remains easy for any single group to assign responsibility for resolving the problem to others. To develop evidence-informed general and targeted recommendations addressing the various stakeholders involved in knowledge generation and dissemination to help overcome the problem of dissemination bias on the basis of previously collated evidence. Based on findings from systematic reviews, document analyses and surveys, we developed general and targeted draft recommendations. During a 2-day workshop in summer 2013, these draft recommendations were discussed with external experts and key stakeholders, and refined following a rigorous and transparent methodological approach. Four general, overarching recommendations applicable to all or most stakeholder groups were formulated, addressing (1) awareness raising, (2) implementation of targeted recommendations, (3) trial registration and results posting, and (4) systematic approaches to evidence synthesis. These general recommendations are complemented and specified by 47 targeted recommendations tailored towards funding agencies, pharmaceutical and device companies, research institutions, researchers (systematic reviewers and trialists), research ethics committees, trial registries, journal editors and publishers, regulatory agencies, benefit (health technology) assessment institutions and legislators. Despite various recent examples of dissemination bias and several initiatives to reduce it, the problem of dissemination bias has not been resolved. Tailored recommendations based on a comprehensive approach will hopefully help increase transparency in biomedical research by overcoming the failure to disseminate negative findings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
[Attitudes and opinions of Palestinian decision-makers about premarital examination law].
El Sharif, Nuha; Rifai, Ayshea; Assi, Sana'a; Al Hmidat, Amjad
2006-11-01
We explored the attitudes and opinions of 90 Palestinian decision-makers about the draft law on premarital examination. The findings revealed that decision-makers were aware of the spread of genetic diseases but not infectious diseases. The majority agreed on the draft law; however, they differed on the mode of its application. Half believed that the law is not ready yet for application due to insufficient financial support to establish the needed infrastructure. The most significant recommendations made by the decision-makers were to: enhance community awareness of the law, ensure proper coordination among the concerned ministries and institutions, and establish a national organization to work on endorsement of the tests and issuance of the appropriate application strategies and regulations.
Li, Wei Bo; Greiter, Matthias; Oeh, Uwe; Hoeschen, Christoph
2011-12-01
The reliability of biokinetic models is essential in internal dose assessments and radiation risk analysis for the public, occupational workers, and patients exposed to radionuclides. In this paper, a method for assessing the reliability of biokinetic models by means of uncertainty and sensitivity analysis was developed. The paper is divided into two parts. In the first part of the study published here, the uncertainty sources of the model parameters for zirconium (Zr), developed by the International Commission on Radiological Protection (ICRP), were identified and analyzed. Furthermore, the uncertainty of the biokinetic experimental measurement performed at the Helmholtz Zentrum München-German Research Center for Environmental Health (HMGU) for developing a new biokinetic model of Zr was analyzed according to the Guide to the Expression of Uncertainty in Measurement, published by the International Organization for Standardization. The confidence interval and distribution of model parameters of the ICRP and HMGU Zr biokinetic models were evaluated. As a result of computer biokinetic modelings, the mean, standard uncertainty, and confidence interval of model prediction calculated based on the model parameter uncertainty were presented and compared to the plasma clearance and urinary excretion measured after intravenous administration. It was shown that for the most important compartment, the plasma, the uncertainty evaluated for the HMGU model was much smaller than that for the ICRP model; that phenomenon was observed for other organs and tissues as well. The uncertainty of the integral of the radioactivity of Zr up to 50 y calculated by the HMGU model after ingestion by adult members of the public was shown to be smaller by a factor of two than that of the ICRP model. It was also shown that the distribution type of the model parameter strongly influences the model prediction, and the correlation of the model input parameters affects the model prediction to a certain extent depending on the strength of the correlation. In the case of model prediction, the qualitative comparison of the model predictions with the measured plasma and urinary data showed the HMGU model to be more reliable than the ICRP model; quantitatively, the uncertainty model prediction by the HMGU systemic biokinetic model is smaller than that of the ICRP model. The uncertainty information on the model parameters analyzed in this study was used in the second part of the paper regarding a sensitivity analysis of the Zr biokinetic models.
Pragmatic ethical basis for radiation protection in diagnostic radiology
Zölzer, Friedo
2016-01-01
Objective: Medical ethics has a tried and tested literature and a global active research community. Even among health professionals, literate and fluent in medical ethics, there is low recognition of radiation protection principles such as justification and optimization. On the other hand, many in healthcare environments misunderstand dose limitation obligations and incorrectly believe patients are protected by norms including a dose limit. Implementation problems for radiation protection in medicine possibly flow from apparent inadequacies of the International Commission on Radiological Protection (ICRP) principles taken on their own, coupled with their failure to transfer successfully to the medical world. Medical ethics, on the other hand, is essentially global, is acceptable in most cultures, is intuitively understood in hospitals, and its expectations are monitored, even by managements. This article presents an approach to ethics in diagnostic imaging rooted in the medical tradition, and alert to contemporary social expectations. ICRP and the International Radiation Protection Association (IRPA), both alert to growing ethical concerns, organized a series of consultations on ethics for general radiation protection in the last few years. Methods: The literature on medical ethics and implicit ICRP ethical values were reviewed qualitatively, with a view to identifying a system that will help guide contemporary behaviour in radiation protection of patients. Application of the system is illustrated in six clinical scenarios. The proposed system is designed, as far as is possible, so as not to be in conflict with the conclusions emerging from the ICRP/IRPA consultations. Results and conclusion: A widely recognized and well-respected system of medical ethics was identified that has global reach and claims acceptance in all cultures. Three values based on this system are grouped with two additional values to provide an ethical framework for application in diagnostic imaging. This system has the potential to be robust and to reach conclusions that are in accord with contemporary medical, social and ethical thinking. The system is not intended to replace the ICRP principles. Rather, it is intended as a well-informed interim approach that will help judge and analyse situations that arouse ethical concerns in radiology. Six scenarios illustrate the practicality of the value system in alerting one to possible deficits in practice. Advances in knowledge: Five widely recognized values and the basis for them are identified to support the contemporary practice of diagnostic radiology. These are essential to complement the widely used ICRP principles pending further development in the area. PMID:26796852
Electricite de France`s ALARA policy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stricker, L.; Rollin, P.
1995-03-01
In 1992, Electricite de France - EDF decided to improve the degree to which radiological protection is incorporated in overall management of the utility and set itself the objective of ensuring the same level of protection for workers from contractors as for those from EDF. This decision was taken in a context marked by a deterioration in exposure figures for French plants and by the new recommendations issued by the ICRP. This document describes the policy adopted by EDF at both corporate and plant level to meet these objectives, by: (1) setting up management systems which were responsive but notmore » cumbersome; (2) a broad policy of motivation; (3) the development and use of suitable tools. The document then describes some quite positive results of EDF`s ALARA policy, giving concrete examples and analyzing the changes in global indicators.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Fewer Animals to Identify Chemical Eye Hazards: Revised Criteria Necessary to Maintain Equivalent Hazard... criteria using results from 3-animal tests that would provide eye hazard classification equivalent to... least 1 positive animal in a 3-animal test to identify eye hazards will provide the same or greater...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
.... Heat stress can result in heat-related illnesses such as heat stroke, heat exhaustion, heat cramps, or... related materials, visit http://www.regulations.gov and enter CDC-2013-0025 in the search field and click... hydration that should be considered? (4) Are there any additional risk factors for heat-related illnesses...
Key Planning Factors for Recovery from a Radiological Terrorism Incident
2012-09-01
United States, Health Phys. 82(5), 591–608. Bromet E.J. (2012). Mental health consequences of the Chernobyl disaster, J Radiol Prot. 2012 Mar; 32(1...Recovery Planning Tools: Recommendations for Developing Regional Disaster Recovery Plans. Draft. Steinhausler, F. (2005), Chernobyl and Goiania Lessons for Responding to Radiological Terrorism. Health Phys. 89(5):566 –574
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... evolving transportation needs, challenges, and opportunities of the global economy. The subcommittee will... develop a work plan for future meetings. DATES: The meeting will be held on September 28, 2010, from 2 to.... Review the status of issue items. 2. Discuss the drafting of recommendations and report. 3. Develop a...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-17
....5 miles of new and upgraded access roads. The Enloe Project would operate automatically in a run-of... run-of-river and implementing agency-recommended ramping rates downstream of the project during... effects on geology and soils and water quality. Run-of-river operation would minimize effects on aquatic...
NASA Technology Area 1: Launch Propulsion Systems
NASA Technical Reports Server (NTRS)
McConnaughey, Paul; Femminineo, Mark; Koelfgen, Syri; Lepsch, Roger; Ryan, Richard M.; Taylor, Steven A.
2011-01-01
This slide presentation reviews the technology advancements plans for the NASA Technology Area 1, Launch Propulsion Systems Technology Area (LPSTA). The draft roadmap reviews various propulsion system technologies that will be developed during the next 25 + years. This roadmap will be reviewed by the National Research Council which will issue a final report, that will include findings and recommendations.
Collected Papers on Poverty Issues. Volume 1: American Poverty Problems and Policies.
ERIC Educational Resources Information Center
Yokelson, Doris, Ed.
This four-volume anthology is comprised of numerous drafts, papers, and reports written by professional staff and consultants of the Hudson Institute. The many chapters are not considered to offer any solutions but to have raised many problems, sorted out and elucidated issues, often in new ways, and suggested recommendations. The present…
32 CFR Appendix A to Part 152 - Guidance to the Joint Service Committee (JSCA)
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the Code Committee established by Article 146 of the UCMJ, with an invitation to submit comments. (4) The draft of the annual review shall set forth any specific recommendations for changes to the... Committee for its consideration under Article 146, UCMJ. (d) Public Notice and Meeting. (1) Proposals to...
The internal dosimetry code PLEIADES.
Fell, T P; Phipps, A W; Smith, T J
2007-01-01
The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts-the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included.
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Draft standard for color AMLCDs in U.S. military aircraft
NASA Astrophysics Data System (ADS)
Hopper, Darrel G.; Dolezal, William K.; Schur, Keith; Liccione, John W.
1994-06-01
Flight instruments have begun to use color active liquid crystal displays (AMLCDs), signaling the beginning of a significant transition from electromechanical and cathode ray tube display designs to AMLCD designs. We have the opportunity with this new technology to establish common products capable of meeting user requirements for sunlight-readable, color and gray scale-capable, high-pixel-count, flat-panel displays for weapon systems. The Wright Laboratory is leading the development of standard and specification documentation for this new generation of display modules based on requirements for U.S. military aircraft. These requirements are similar in many ways to those of both the civil aviation and automotive industries. Accordingly, commonality with these applications is incorporated, where possible, along with the requirements for all military combat applications. Industry and government organizations are involved in this process through workshops and draft review processes. Military procurement specifications for combat system applications may use this information as a source of recommended best practice for this new generation of digital flat panel displays. The draft standard will be revised based upon continuing feedback by early 1995.
Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G
2010-03-01
These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.
Field Testing of Alternative Cookstove Performance in a Rural Setting of Western India
Muralidharan, Veena; Sussan, Thomas E.; Limaye, Sneha; Koehler, Kirsten; Williams, D’Ann L.; Rule, Ana M.; Juvekar, Sanjay; Breysse, Patrick N.; Salvi, Sundeep; Biswal, Shyam
2015-01-01
Nearly three billion people use solid fuels for cooking and heating, which leads to extremely high levels of household air pollution and is a major cause of morbidity and mortality. Many stove manufacturers have developed alternative cookstoves (ACSs) that are aimed at reducing emissions and fuel consumption. Here, we tested a traditional clay chulha cookstove (TCS) and five commercially available ACSs, including both natural draft (Greenway Smart Stove, Envirofit PCS-1) and forced draft stoves (BioLite HomeStove, Philips Woodstove HD4012, and Eco-Chulha XXL), in a test kitchen in a rural village of western India. Compared to the TCS, the ACSs produced significant reductions in particulate matter less than 2.5 µm (PM2.5) and CO concentrations (Envirofit: 22%/16%, Greenway: 24%/42%, BioLite: 40%/35%, Philips: 66%/55% and Eco-Chulha: 61%/42%), which persisted after normalization for fuel consumption or useful energy. PM2.5 and CO concentrations were lower for forced draft stoves than natural draft stoves. Furthermore, the Philips and Eco-Chulha units exhibited higher cooking efficiency than the TCS. Despite significant reductions in concentrations, all ACSs failed to achieve PM2.5 levels that are considered safe by the World Health Organization (ACSs: 277–714 μg/m3 or 11–28 fold higher than the WHO recommendation of 25 μg/m3;). PMID:25654775
The conversion of exposures due to radon into the effective dose: the epidemiological approach.
Beck, T R
2017-11-01
The risks and dose conversion coefficients for residential and occupational exposures due to radon were determined with applying the epidemiological risk models to ICRP representative populations. The dose conversion coefficient for residential radon was estimated with a value of 1.6 mSv year -1 per 100 Bq m -3 (3.6 mSv per WLM), which is significantly lower than the corresponding value derived from the biokinetic and dosimetric models. The dose conversion coefficient for occupational exposures with applying the risk models for miners was estimated with a value of 14 mSv per WLM, which is in good accordance with the results of the dosimetric models. To resolve the discrepancy regarding residential radon, the ICRP approaches for the determination of risks and doses were reviewed. It could be shown that ICRP overestimates the risk for lung cancer caused by residential radon. This can be attributed to a wrong population weighting of the radon-induced risks in its epidemiological approach. With the approach in this work, the average risks for lung cancer were determined, taking into account the age-specific risk contributions of all individuals in the population. As a result, a lower risk coefficient for residential radon was obtained. The results from the ICRP biokinetic and dosimetric models for both, the occupationally exposed working age population and the whole population exposed to residential radon, can be brought in better accordance with the corresponding results of the epidemiological approach, if the respective relative radiation detriments and a radiation-weighting factor for alpha particles of about ten are used.
SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palomo-Llinares, R; Gimeno-Olmos, J; Carmona Meseguer, V
Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dosemore » that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Standard Dose Head protocol (100 kVp, 80 mA, 8 ms and 200 degree of rotation).The measurements were taken with thermoluminescence (TLD) EXTRAD (Harshaw) dosimeters placed in an anthropomorphic phantom over the eye and under 3 mm of bolus material to mimic the lens position. The center of the head was placed at the isocenter. To reduce TLD energy dependence, they were calibrated at the used beam quality. Results: The average lens dose at the lens in the OBI v 1.5 systems of the Clinac iX and the True Beam is 0.071 and 0.076 cGy/CBCT, respectively. Conclusions: The extra absorbed doses that receive the eye lenses due to one CBCT acquisition with the studied protocol is far below the new ICRP recommended threshold for the lens. However, the addition effect of several CBCT acquisition during the whole treatment should be taken into account.« less
A generic biokinetic model for carbon-14 labelled compounds
NASA Astrophysics Data System (ADS)
Manger, Ryan Paul
Carbon-14, a radioactive nuclide, is used in many industrial applications. Due to its wide range of uses in industry, many workers are at risk of accidental internal exposure to 14C. Being a low energy beta emitter, 14C is not a significant external radiation hazard, but the internal consequences posed by 14C are important, especially because of its long half life of 5730 years [46]. The current biokinetic model recommended by the International Commission on Radiological Protection (ICRP) is a conservative estimate of how radiocarbon is treated by the human body. The ICRP generic radiocarbon model consists of a single compartment representing the entire human body. This compartment has a biological half life of 40 days yielding an effective dose coefficient of 5.8x10-10 Sv B q-1 [44, 45, 49, 53, 54]. This overestimates the dose of all radiocarbon compounds that have been studied [96]. An improved model has been developed that includes and alimentary tract, a urinary bladder, CO2 model, and an "Other" compartment used to model systemic tissues. The model can be adapted to replicate any excretion curve and excretion pattern. In addition, the effective dose coefficient produced by the updated model is near the mean effective dose coefficient of carbon compounds that have been considered in this research. The major areas of improvement are: more anatomically significant, a less conservative dose coefficient, and the ability to manipulate the model for known excretion data. Due to the wide variety of carbon compounds, it is suggested that specific biokinetic models be implemented for known radiocarbon substances. If the source of radiocarbon is dietary, then the physiologically based model proposed by Whillans [102] that splits all ingested radiocarbon compounds into carbohydrates, fats, and proteins should be used.
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Qiu, Rui; Li, Junli; Zhang, Zhan; Liu, Liye; Bi, Lei; Ren, Li
2009-02-01
A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface.
Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal
2016-01-01
The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.
Pharmacologic management of chronic neuropathic pain
Mu, Alex; Weinberg, Erica; Moulin, Dwight E.; Clarke, Hance
2017-01-01
Abstract Objective To provide family physicians with a practical clinical summary of the Canadian Pain Society (CPS) revised consensus statement on the pharmacologic management of neuropathic pain. Quality of evidence A multidisciplinary interest group within the CPS conducted a systematic review of the literature on the current treatments of neuropathic pain in drafting the revised consensus statement. Main message Gabapentinoids, tricyclic antidepressants, and serotonin-norepinephrine reuptake inhibitors are the first-line agents for treating neuropathic pain. Tramadol and other opioids are recommended as second-line agents, while cannabinoids are newly recommended as third-line agents. Other anticonvulsants, methadone, tapentadol, topical lidocaine, and botulinum toxin are recommended as fourth-line agents. Conclusion Many pharmacologic analgesics exist for the treatment of neuropathic pain. Through evidence-based recommendations, the CPS revised consensus statement helps guide family physicians in the management of patients with neuropathic pain. PMID:29138154
Consensus standards for introductory e-learning courses in human participants research ethics.
Williams, John R; Sprumont, Dominique; Hirtle, Marie; Adebamowo, Clement; Braunschweiger, Paul; Bull, Susan; Burri, Christian; Czarkowski, Marek; Fan, Chien Te; Franck, Caroline; Gefenas, Eugenjius; Geissbuhler, Antoine; Klingmann, Ingrid; Kouyaté, Bocar; Kraehenbhul, Jean-Pierre; Kruger, Mariana; Moodley, Keymanthri; Ntoumi, Francine; Nyirenda, Thomas; Pym, Alexander; Silverman, Henry; Tenorio, Sara
2014-06-01
This paper reports the results of a workshop held in January 2013 to begin the process of establishing standards for e-learning programmes in the ethics of research involving human participants that could serve as the basis of their evaluation by individuals and groups who want to use, recommend or accredit such programmes. The standards that were drafted at the workshop cover the following topics: designer/provider qualifications, learning goals, learning objectives, content, methods, assessment of participants and assessment of the course. The authors invite comments on the draft standards and eventual endorsement of a final version by all stakeholders. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Basis for the ICRP’s updated biokinetic model for carbon inhaled as CO 2
Leggett, Richard W.
2017-03-02
Here, the International Commission on Radiological Protection (ICRP) is updating its biokinetic and dosimetric models for occupational intake of radionuclides (OIR) in a series of reports called the OIR series. This paper describes the basis for the ICRP's updated biokinetic model for inhalation of radiocarbon as carbon dioxide (CO 2) gas. The updated model is based on biokinetic data for carbon isotopes inhaled as carbon dioxide or injected or ingested as bicarbonatemore » $$({{{\\rm{HCO}}}_{3}}^{-}).$$ The data from these studies are expected to apply equally to internally deposited (or internally produced) carbon dioxide and bicarbonate based on comparison of excretion rates for the two administered forms and the fact that carbon dioxide and bicarbonate are largely carried in a common form (CO 2–H$${{{\\rm{CO}}}_{3}}^{-})$$ in blood. Compared with dose estimates based on current ICRP biokinetic models for inhaled carbon dioxide or ingested carbon, the updated model will result in a somewhat higher dose estimate for 14C inhaled as CO 2 and a much lower dose estimate for 14C ingested as bicarbonate.« less
ICRP Publication 107. Nuclear decay data for dosimetric calculations.
Eckerman, K; Endo, A
2008-01-01
In this report, the Commission provides an electronic database of the physical data needed in calculations of radionuclide-specific protection and operational quantities. This database supersedes the data of Publication 38 (ICRP, 1983), and will be used in future ICRP publications of dose coefficients for the intake of or exposure to radionuclides in the workplace and the environment.The database contains information on the half-lives, decay chains, and yields and energies of radiations emitted in nuclear transformations of 1252 radionuclides of 97 elements. The CD accompanying the publication provides electronic access to complete tables of the emitted radiations, as well as the beta and neutron spectra. The database has been constructed such that user-developed software can extract the data needed for further calculations of a radionuclide of interest. A Windows-based application is provided to display summary information on a user-specified radionuclide, as well as the general characterisation of the nuclides contained in the database. In addition, the application provides a means by which the user can export the emissions of a specified radionuclide for use in subsequent calculations.
Basis for the ICRP’s updated biokinetic model for carbon inhaled as CO 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leggett, Richard W.
Here, the International Commission on Radiological Protection (ICRP) is updating its biokinetic and dosimetric models for occupational intake of radionuclides (OIR) in a series of reports called the OIR series. This paper describes the basis for the ICRP's updated biokinetic model for inhalation of radiocarbon as carbon dioxide (CO 2) gas. The updated model is based on biokinetic data for carbon isotopes inhaled as carbon dioxide or injected or ingested as bicarbonatemore » $$({{{\\rm{HCO}}}_{3}}^{-}).$$ The data from these studies are expected to apply equally to internally deposited (or internally produced) carbon dioxide and bicarbonate based on comparison of excretion rates for the two administered forms and the fact that carbon dioxide and bicarbonate are largely carried in a common form (CO 2–H$${{{\\rm{CO}}}_{3}}^{-})$$ in blood. Compared with dose estimates based on current ICRP biokinetic models for inhaled carbon dioxide or ingested carbon, the updated model will result in a somewhat higher dose estimate for 14C inhaled as CO 2 and a much lower dose estimate for 14C ingested as bicarbonate.« less
Lee, James
2009-01-01
The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.
2014-01-01
Background The potential of clinical practice guidelines has not been realized due to inconsistent adoption in clinical practice. Optimising intrinsic characteristics of guidelines (e.g., its wording and format) that are associated with uptake (as perceived by their end users) may have potential. Using findings from a realist review on guideline uptake and consultation with experts in guideline development, we designed a conceptual version of a future tool called Guideline Implementability Tool (GUIDE-IT). The tool will aim to involve family physicians in the guideline development process by providing a process to assess draft guideline recommendations. This feedback will then be given back to developers to consider when finalizing the recommendations. As guideline characteristics are best assessed by end-users, the objectives of the current study were to explore how family physicians perceive guideline implementability, and to determine what components should comprise the final GUIDE-IT prototype. Methods We conducted a qualitative study with family physicians inToronto, Ontario. Two experienced investigators conducted one-hour interviews with family physicians using a semi-structured interview guide to 1) elicit feedback on perceptions on guideline implementability; 2) to generate a discussion in response to three draft recommendations; and 3) to provide feedback on the conceptual GUIDE-IT. Sessions were audio taped and transcribed verbatim. Data collection and analysis were guided by content analyses. Results 20 family physicians participated. They perceived guideline uptake according to facilitators and barriers across 6 categories of guideline implementability (format, content, language, usability, development, and the practice environment). Participants’ feedback on 3 draft guideline recommendations were grouped according to guideline perception, cognition, and agreement. When asked to comment on GUIDE-IT, most respondents believed that the tool would be useful, but urged to involve “regular” or community family physicians in the process, and suggested that an online system would be the most efficient way to deliver it. Conclusions Our study identified facilitators and barriers of guideline implementability from the perspective of community and academic family physicians that will be used to build our GUIDE-IT prototype. Our findings build on current knowledge by showing that family physicians perceive guideline uptake mostly according to factors that are in the control of guideline developers. PMID:24476491
Measuring the benefits of protected areas: a critical perspective on the IUCN guidelines
Dick Stanley; Luc Perron
1998-01-01
The International Union for the Conservation of Nature has drafted guidelines to help managers of protected natural areas to develop economic arguments in defense of those areas. The guidelines identify a series of benefits which protected areas might produce and which all have real markets in the outside world, and recommend that managers focus their arguments on...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... Virus From Donors of Human Cells, Tissues, and Cellular and Tissue-Based Products; Availability AGENCY... to Reduce the Risk of Transmission of West Nile Virus From Donors of Human Cells, Tissues, and... testing for West Nile Virus (WNV) using an FDA-licensed donor screening test. The guidance recommends the...
Proposed Master Plan for Higher Education in New Jersey.
ERIC Educational Resources Information Center
New Jersey State Commission on Higher Education.
The draft Master Plan was developed in response to requirements of the New Jersey Higher Education Restructuring Act of 1994. The plan proposes a vision and broad policy recommendations for New Jersey higher education into the next century. The focus of the plan is on the critical needs of the state and how higher education can help in addressing…
ERIC Educational Resources Information Center
Russian Education and Society, 1998
1998-01-01
Provides the discussion from the parliamentary hearings of the Russian Committee of the State Duma for Education and Science, held at Moscow State University, that focused on the draft of a plan to change some of the basic elements of Russian education. Offers recommendations of the parliamentary hearings and three letters. (CMK)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-07
.... While the COE failed to secure funds to do a detailed five-year study, its emergency management team recommended extensive bank hardening with rock, and dredging of the river channel. Estimated one-time cost is... floods. Until now, the NPS has addressed problems on a case-by-case basis throughout the valley with the...
The Error Prone Model and the Basic Grants Validation Selection System. Draft Final Report.
ERIC Educational Resources Information Center
System Development Corp., Falls Church, VA.
An evaluation of existing and proposed mechanisms to ensure data accuracy for the Pell Grant program is reported, and recommendations for efficient detection of fraud and error in the program are offered. One study objective was to examine the existing system of pre-established criteria (PEC), which are validation criteria that select students on…
Implementing Best Practices for Major Business Processes in the Department of Defense
2014-07-24
95 Figures and Tables Figure 1- Past budget declines following major military engagements...US Navy and COL Leslie Caballero, US Army served as the military representatives. APPROACH The Task Group’s draft findings and recommendations were...Group interviewed over 30 individuals from government, think tanks, and private industry, including current and recent DoD senior military and
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
... project in April 2000. This study recommended a 600- foot (ft) extension of the existing auxiliary lock chamber to a length of 1200 ft. The project was authorized by Congress in 2000; however, no funds have been appropriated for project construction. Due to the amount of time that has elapsed since completion...
Assignment Report on Library Banks in Health Institution in Indonesia (Draft).
ERIC Educational Resources Information Center
Urata, Takeo
The medical library needs of Indonesia were surveyed and recommendations for improving the existing situation are made based on the results of the survey. The survey indicates that: (1) the library collections are out of date and inadequate, (2) there is a need for more and better trained medical librarians and library assistants; (3) there is no…
NASA Technical Reports Server (NTRS)
Tarter, Jill; Backus, Peter
1995-01-01
Curriculum materials based on the search for extraterrestrial intelligence (SETI) were developed for grades 3 through 9 science classes. The project was supported in part by NASA. Six teacher's guides, plus ancillary visuals, addressing topics in astronomy, biology, chemistry, geosciences, and physics as well as mathematics, social sciences, and language arts, were designed by a team of teachers, scientists. curriculum developers, and artists. First drafts were piloted by 10 design team teachers; revised drafts were field tested by 109 teachers in 30 states. Extensive feedback from these teachers and their students and reviews by scientists were used to revise materials prior to submission to the publisher. The field test teachers overall ranking of all guides (data from individual lesson feedback forms) was 431 on a one low to five high scale; 85% found the content appropriate to course and grade level and 75% indicated they had no reservations about using the materials again or recommending them to colleagues. The ratio of liked to disliked student responses (from 1305 student letters) was 70:30. Most recommendations from the teachers, students, and science reviewers were incorporated in the final versions for the guides, published by Libraries Unlimited/Teacher Ideas Press, 1995.
Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee
2016-04-01
The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1mSv y(-1) for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.
KDEP: A resource for calculating particle deposition in the respiratory tract
Klumpp, John A.; Bertelli, Luiz
2017-08-01
This study presents KDEP, an open-source implementation of the ICRP lung deposition model developed by the authors. KDEP, which is freely available to the public, can be used to calculate lung deposition values under a variety of different conditions using the ICRP methodology. The paper describes how KDEP implements this model and discusses some key points of the implementation. The published lung deposition values for intakes by workers were reproduced, and new deposition values were calculated for intakes by members of the public. KDEP can be obtained for free at github.com or by emailing the authors directly.
Suzuki, Akira; Matsubara, Kosuke; Sasa, Yuko
2018-04-01
The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by ~60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.
Sugiyama, Daisuke; Hattori, Takatoshi
2013-01-01
In environmental remediation after nuclear accidents, radioactive wastes have to be appropriately managed in existing exposure situations with contamination resulting from the emission of radionuclides by such accidents. In this paper, a framework of radiation protection from radioactive waste management in existing exposure situations for application to the practical and reasonable waste management in contaminated areas, referring to related ICRP recommendations was proposed. In the proposed concept, intermediate reference levels for waste management are adopted gradually according to the progress of the reduction in the existing ambient dose in the environment on the basis of the principles of justification and optimisation by taking into account the practicability of the management of radioactive waste and environmental remediation. It is essential to include the participation of relevant stakeholders living in existing exposure situations in the selection of reference levels for the existing ambient dose and waste management.
Sugiyama, Daisuke; Hattori, Takatoshi
2013-01-01
In environmental remediation after nuclear accidents, radioactive wastes have to be appropriately managed in existing exposure situations with contamination resulting from the emission of radionuclides by such accidents. In this paper, a framework of radiation protection from radioactive waste management in existing exposure situations for application to the practical and reasonable waste management in contaminated areas, referring to related ICRP recommendations was proposed. In the proposed concept, intermediate reference levels for waste management are adopted gradually according to the progress of the reduction in the existing ambient dose in the environment on the basis of the principles of justification and optimisation by taking into account the practicability of the management of radioactive waste and environmental remediation. It is essential to include the participation of relevant stakeholders living in existing exposure situations in the selection of reference levels for the existing ambient dose and waste management. PMID:22719047
Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.
Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less
The radiation protection problems of high altitude and space flight
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fry, R.J.M.
1993-04-01
This paper considers the radiation environment in aircraft at high altitudes and spacecraft in low earth orbit and in deep space and the factors that influence the dose equivalents. Altitude, latitude and solar cycle are the major influences for flights below the radiation belts. In deep space, solar cycle and the occurrence of solar particle events are the factors of influence. The major radiation effects of concern are cancer and infertility in males. In high altitude aircraft the radiation consists mainly of protons and neutrons, with neutrons contributing about half the equivalent dose. The average dose rate at altitudes ofmore » transcontinental flights that approach the polar regions are greater by a factor of about 2.5 than on routes at low latitudes. Current estimates of does to air crews suggest they are well within the ICRP (1990) recommended dose limits for radiation workers.« less
The making of nursing practice law in Lebanon: a policy analysis case study.
El-Jardali, Fadi; Hammoud, Rawan; Younan, Lina; Nuwayhid, Helen Samaha; Abdallah, Nadine; Alameddine, Mohammad; Bou-Karroum, Lama; Salman, Lana
2014-09-05
Evidence-informed decisions can strengthen health systems, improve health, and reduce health inequities. Despite the Beijing, Montreux, and Bamako calls for action, literature shows that research evidence is underemployed in policymaking, especially in the East Mediterranean region (EMR). Selecting the draft nursing practice law as a case study, this policy analysis exercise aims at generating in-depth insights on the public policymaking process, identifying the factors that influence policymaking and assessing to what extent evidence is used in this process. This study utilized a qualitative research design using a case study approach and was conducted in two phases: data collection and analysis, and validation. In the first phase, data was collected through key informant interviews that covered 17 stakeholders. In the second phase, a panel discussion was organized to validate the findings, identify any gaps, and gain insights and feedback of the panelists. Thematic analysis was conducted and guided by the Walt & Gilson's "Policy Triangle Framework" as themes were categorized into content, actors, process, and context. Findings shed light on the complex nature of health policymaking and the unstructured approach of decision making. This study uncovered the barriers that hindered the progress of the draft nursing law and the main barriers against the use of evidence in policymaking. Findings also uncovered the risk involved in the use of international recommendations without the involvement of stakeholders and without accounting for contextual factors and implementation barriers. Findings were interpreted within the context of the Lebanese political environment and the power play between stakeholders, taking into account equity considerations. This policy analysis exercise presents findings that are helpful for policymakers and all other stakeholders and can feed into revising the draft nursing law to reach an effective alternative that is feasible in Lebanon. Our findings are relevant in local and regional context as policymakers and other stakeholders can benefit from this experience when drafting laws and at the global context, as international organizations can consider this case study when developing global guidance and recommendations.
Nantucket, Ma. Climate Protection Action Plan: A Public Outreach Strategy
NASA Astrophysics Data System (ADS)
Petrik, C.; Stephenson, A.; Petsch, S.
2009-12-01
As communities and municipalities gain a better understanding of climate change, they are exploring the ways in which to work towards adaptation and mitigation. One strategy that the Island of Nantucket, Massachusetts turned toward is the drafting of a Climate Protection Action Plan (CPAP). The CPAP was developed during the summer of 2009 to meet three goals: (1) assist the Town of Nantucket in creating a framework to help them reduce CO2 emissions; (2) educate the municipality and community in techniques that promote energy efficiency and sustainability on the island; and (3) document past, present and future approaches adopted by the Town towards emissions reduction and energy sustainability. In particular, this project focused on using local strengths and natural resources identified by island stakeholders that may help the island to mitigate carbon emissions and adapt to climate change.. Drafting the CPAP provided community members and politicians with an opportunity to become better educated in the science of climate change and to learn how climate change will affect their community. On the island of Nantucket, leaders in the religious, civic, and political communities were brought into a conversation about how each group could contribute to reducing greenhouse gas emissions. A geosciences graduate student was brought into the CPAP team as a climate fellow to facilitate this conversation. This provided the foundation for stakeholder recommendations incorporated into the CPAP. This capacity-building model served as an effective way to create an informal learning environment about climate change that allowed members of the island community to directly participate in developing their locally appropriate climate protection strategy. The draft CPAP developed through this study and presented to the Town of Nantucket comprises assessments and recommendations in public research and education; building and energy efficiency; transportation; renewable energy; and carbon offsets. Through the drafting of these types of Plans, geoscientists have the unique opportunity to offer a scientific foundation to communities that are looking to better understand climate change, its projected affects, and how they can best develop plans for mitigation and adaptation.
Lee, Amanda J; Kane, Sarah; Ramsey, Rebecca; Good, Elizabeth; Dick, Mathew
2016-04-12
Price and affordability of foods are important determinants of health. Targeted food pricing policies may help improve population diets. However, methods producing comparable data to inform relevant policy decisions are lacking in Australia and globally. The objective was to develop and pilot standardised methods to assess the price, relative price and affordability of healthy (recommended) and current (unhealthy) diets and test impacts of a potential policy change. Methods followed the optimal approach proposed by INFORMAS using recent Australian dietary intake data and guidelines. Draft healthy and current (unhealthy) diet baskets were developed for five household structures. Food prices were collected in stores in a high and low SES location in Brisbane, Australia. Diet prices were calculated and compared with household incomes, and with potential changes to the Australian Taxation System. Wilcoxen-signed rank tests were used to compare differences in price. The draft tools and protocols were deemed acceptable at household level, but methods could be refined. All households spend more on current (unhealthy) diets than required to purchase healthy (recommended) diets, with the majority (53-64 %) of the food budget being spent on 'discretionary' choices, including take-away foods and alcohol. A healthy diet presently costs between 20-31 % of disposable income of low income households, but would become unaffordable for these families under proposed changes to expand the GST to apply to all foods in Australia. Results confirmed that diet pricing methods providing meaningful, comparable data to inform potential fiscal and health policy actions can be developed, but draft tools should be refined. Results suggest that healthy diets can be more affordable than current (unhealthy) diets in Australia, but other factors may be as important as price in determining food choices.
Talke, Pekka O; Sharma, Deepak; Heyer, Eric J; Bergese, Sergio D; Blackham, Kristine A; Stevens, Robert D
2014-04-01
Literature on the anesthetic management of endovascular treatment of acute ischemic stroke (AIS) is limited. Anesthetic management during these procedures is still mostly dependent on individual or institutional preferences. Thus, the Society of Neuroscience in Anesthesiology and Critical Care (SNACC) created a task force to provide expert consensus recommendations on anesthetic management of endovascular treatment of AIS. The task force conducted a systematic literature review (up to August 2012). Because of the limited number of research articles relating to this subject, the task force solicited opinions from experts in this area. The task force created a draft consensus statement based on the available data. Classes of recommendations and levels of evidence were assigned to articles specifically addressing anesthetic management during endovascular treatment of stroke using the standard American Heart Association evidence rating scheme. The draft consensus statement was reviewed by the Task Force, SNACC Executive Committee and representatives of Society of NeuroInterventional Surgery (SNIS) and Neurocritical Care Society (NCS) reaching consensus on the final document. For this consensus statement the anesthetic management of endovascular treatment of AIS was subdivided into 12 topics. Each topic includes a summary of available data followed by recommendations. This consensus statement is intended for use by individuals involved in the care of patients with acute ischemic stroke, such as anesthesiologists, interventional neuroradiologists, neurologists, neurointensivists, and neurosurgeons.
Talke, Pekka O; Sharma, Deepak; Heyer, Eric J; Bergese, Sergio D; Blackham, Kristine A; Stevens, Robert D
2014-08-01
Literature on the anesthetic management of endovascular treatment of acute ischemic stroke (AIS) is limited. Anesthetic management during these procedures is still mostly dependent on individual or institutional preferences. Thus, the Society of Neuroscience in Anesthesiology and Critical Care (SNACC) created a task force to provide expert consensus recommendations on anesthetic management of endovascular treatment of AIS. The task force conducted a systematic literature review (up to August 2012). Because of the limited number of research articles relating to this subject, the task force solicited opinions from experts in this area. The task force created a draft consensus statement based on the available data. Classes of recommendations and levels of evidence were assigned to articles specifically addressing anesthetic management during endovascular treatment of stroke using the standard American Heart Association evidence rating scheme. The draft consensus statement was reviewed by the Task Force, SNACC Executive Committee and representatives of Society of NeuroInterventional Surgery (SNIS) and Neurocritical Care Society (NCS) reaching consensus on the final document. For this consensus statement the anesthetic management of endovascular treatment of AIS was subdivided into 12 topics. Each topic includes a summary of available data followed by recommendations. This consensus statement is intended for use by individuals involved in the care of patients with acute ischemic stroke, such as anesthesiologists, interventional neuroradiologists, neurologists, neurointensivists and neurosurgeons. © 2014 American Heart Association, Inc.
Bair, W J
1989-01-01
In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users. This should facilitate application of the revised human respiratory tract model to worldwide radiation protection needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watson, David J.; Strom, Daniel J.
This paper is part three of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. The radionuclides of interest are the 238U series (14 nuclides), the actinium series (headed by 235U; 11 nuclides), and the 232Th series (11 nuclides); primordial radionuclides 87Rb and 40K; cosmogenic and fallout radionuclides 14C and 3H; and purely anthropogenic radionuclides 137Cs-137mBa, 129I and 90Sr-90Y. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludesmore » intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Part two described the methods used to organize the data collected in part one and segregate it into the ages and genders defined by the study, imputed missing values from the existing data, apportioned activity in bone, and imputed activity in hollow organ contents and the remainder of the body. This paper estimates equivalent doses to target tissues from source regions and maps target tissues to lists of tissues with International Commission on Radiation Protection (ICRP) tissue-weighting factors or to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue-weighting factors recommended in 1977, 1990, and 2007, are then calculated, and an upper bound of variability of the effective dose is estimated by calculating the average coefficients of variation (CV), assuming all variance is due to variability. Most of the data were for adult males, whose average annual effective dose is estimated to be 337 μSv (CV = 0.65, geometric mean = 283 μSv, geometric standard deviation sG = 1.81) using 2007 ICRP tissue-weighting factors. This result is between the National Council on Radiation Protection & Measurements’ 1987 estimate of 390 μSv (using 1977 wTs) and its 2009 estimate of 285 μSv (using 2007 wTs) and is higher than the United Nations Scientific Committee on the Effects of Atomic Radiation’s 2000 estimate of 310 μSv (using 1990 wTs). The methods and software developed for this project are sufficiently detailed and sufficiently general to be usable with autopsy data from any or all countries.« less
The United Nations contribution towards an international agreement on remote sensing
NASA Technical Reports Server (NTRS)
Menter, M.
1976-01-01
The recommendations of the Legal Subcommittee of the United Nations committee for the Peaceful Uses of Space concerning satellite remote sensing are considered. Detailed studies of the Scientific and Technical Subcommittee of this committee are discussed with emphasis on three draft proposals submitted to it on remote sensing by (1) France and the USSR, (2) Latin American countries, and (3) the United States.
ERIC Educational Resources Information Center
Walker, Ben
2008-01-01
In August 2007, an $11.2 million proposal for a shared statewide high-density storage facility was submitted to the Board of Governors, the governing body of the State University System in Florida. The project was subsequently approved at a slightly lower level and funding was delayed until 2010/2011. The experiences of coordinating data…
Johnson, Mariah M; Leachman, Sancy A; Aspinwall, Lisa G; Cranmer, Lee D; Curiel-Lewandrowski, Clara; Sondak, Vernon K; Stemwedel, Clara E; Swetter, Susan M; Vetto, John; Bowles, Tawnya; Dellavalle, Robert P; Geskin, Larisa J; Grossman, Douglas; Grossmann, Kenneth F; Hawkes, Jason E; Jeter, Joanne M; Kim, Caroline C; Kirkwood, John M; Mangold, Aaron R; Meyskens, Frank; Ming, Michael E; Nelson, Kelly C; Piepkorn, Michael; Pollack, Brian P; Robinson, June K; Sober, Arthur J; Trotter, Shannon; Venna, Suraj S; Agarwala, Sanjiv; Alani, Rhoda; Averbook, Bruce; Bar, Anna; Becevic, Mirna; Box, Neil; E Carson, William; Cassidy, Pamela B; Chen, Suephy C; Chu, Emily Y; Ellis, Darrel L; Ferris, Laura K; Fisher, David E; Kendra, Kari; Lawson, David H; Leming, Philip D; Margolin, Kim A; Markovic, Svetomir; Martini, Mary C; Miller, Debbie; Sahni, Debjani; Sharfman, William H; Stein, Jennifer; Stratigos, Alexander J; Tarhini, Ahmad; Taylor, Matthew H; Wisco, Oliver J; Wong, Michael K
2017-01-01
Melanoma is usually apparent on the skin and readily detected by trained medical providers using a routine total body skin examination, yet this malignancy is responsible for the majority of skin cancer-related deaths. Currently, there is no national consensus on skin cancer screening in the USA, but dermatologists and primary care providers are routinely confronted with making the decision about when to recommend total body skin examinations and at what interval. The objectives of this paper are: to propose rational, risk-based, data-driven guidelines commensurate with the US Preventive Services Task Force screening guidelines for other disorders; to compare our proposed guidelines to recommendations made by other national and international organizations; and to review the US Preventive Services Task Force's 2016 Draft Recommendation Statement on skin cancer screening. PMID:28758010
The advanced orbiting systems testbed program: Results to date
NASA Technical Reports Server (NTRS)
Newsome, Penny A.; Otranto, John F.
1993-01-01
The Consultative Committee for Space Data Systems Recommendations for Packet Telemetry and Advanced Orbiting Systems (AOS) propose standard solutions to data handling problems common to many types of space missions. The Recommendations address only space/ground and space/space data handling systems. Goddard Space Flight Center's AOS Testbed (AOST) Program was initiated to better understand the Recommendations and their impact on real-world systems, and to examine the extended domain of ground/ground data handling systems. Central to the AOST Program are the development of an end-to-end Testbed and its use in a comprehensive testing program. Other Program activities include flight-qualifiable component development, supporting studies, and knowledge dissemination. The results and products of the Program will reduce the uncertainties associated with the development of operational space and ground systems that implement the Recommendations. The results presented in this paper include architectural issues, a draft proposed standardized test suite and flight-qualifiable components.
Mu, Alex; Weinberg, Erica; Moulin, Dwight E; Clarke, Hance
2017-11-01
To provide family physicians with a practical clinical summary of the Canadian Pain Society (CPS) revised consensus statement on the pharmacologic management of neuropathic pain. A multidisciplinary interest group within the CPS conducted a systematic review of the literature on the current treatments of neuropathic pain in drafting the revised consensus statement. Gabapentinoids, tricyclic antidepressants, and serotonin-norepinephrine reuptake inhibitors are the first-line agents for treating neuropathic pain. Tramadol and other opioids are recommended as second-line agents, while cannabinoids are newly recommended as third-line agents. Other anticonvulsants, methadone, tapentadol, topical lidocaine, and botulinum toxin are recommended as fourth-line agents. Many pharmacologic analgesics exist for the treatment of neuropathic pain. Through evidence-based recommendations, the CPS revised consensus statement helps guide family physicians in the management of patients with neuropathic pain. Copyright© the College of Family Physicians of Canada.
Clinical Practice Guideline: Safe Medication Use in the ICU.
Kane-Gill, Sandra L; Dasta, Joseph F; Buckley, Mitchell S; Devabhakthuni, Sandeep; Liu, Michael; Cohen, Henry; George, Elisabeth L; Pohlman, Anne S; Agarwal, Swati; Henneman, Elizabeth A; Bejian, Sharon M; Berenholtz, Sean M; Pepin, Jodie L; Scanlon, Mathew C; Smith, Brian S
2017-09-01
To provide ICU clinicians with evidence-based guidance on safe medication use practices for the critically ill. PubMed, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, CINAHL, Scopus, and ISI Web of Science for relevant material to December 2015. Based on three key components: 1) environment and patients, 2) the medication use process, and 3) the patient safety surveillance system. The committee collectively developed Population, Intervention, Comparator, Outcome questions and quality of evidence statements pertaining to medication errors and adverse drug events addressing the key components. A total of 34 Population, Intervention, Comparator, Outcome questions, five quality of evidence statements, and one commentary on disclosure was developed. Subcommittee members were assigned selected Population, Intervention, Comparator, Outcome questions or quality of evidence statements. Subcommittee members completed their Grading of Recommendations Assessment, Development, and Evaluation of the question with his/her quality of evidence assessment and proposed strength of recommendation, then the draft was reviewed by the relevant subcommittee. The subcommittee collectively reviewed the evidence profiles for each question they developed. After the draft was discussed and approved by the entire committee, then the document was circulated among all members for voting on the quality of evidence and strength of recommendation. The committee followed the principles of the Grading of Recommendations Assessment, Development, and Evaluation system to determine quality of evidence and strength of recommendations. This guideline evaluates the ICU environment as a risk for medication-related events and the environmental changes that are possible to improve safe medication use. Prevention strategies for medication-related events are reviewed by medication use process node (prescribing, distribution, administration, monitoring). Detailed considerations to an active surveillance system that includes reporting, identification, and evaluation are discussed. Also, highlighted is the need for future research for safe medication practices that is specific to critically ill patients.
Beulke, Sabine; van Beinum, Wendy; Suddaby, Laura
2015-04-01
First-tier regulatory exposure assessments for pesticides assume that pesticide sorption is instantaneous and fully reversible. In European Union (EU) regulatory guidance, an increase in sorption over time ("aged sorption") can be considered at the higher tier to refine predicted environmental concentrations in groundwater. Research commissioned by the UK Chemicals Regulation Directorate (CRD), funded by the Department for Environment Food & Rural Affairs (Defra), formed the basis of a draft regulatory guidance document proposing 1) a protocol on how to measure aged sorption of parent compounds in laboratory studies, 2) procedures to fit kinetic models to the experimental data, 3) criteria to test the reliability of the parameters, and 4) procedures for use of the parameters in the groundwater exposure assessment. The draft guidance was revised after feedback from stakeholders and testing of the guidance was performed against real data sets by an independent consultancy. The Chemicals Regulation Directorate submitted the revised document to the European Food Safety Authority (EFSA) for scrutiny. This article gives an overview of the draft guidance and explains the reasoning behind the recommendations made. 2015 Crown Copyright; Published 2015 SETAC.
Final Report of the NASA Technology Readiness Assessment (TRA) Study Team
NASA Technical Reports Server (NTRS)
Hirshorn, Steven; Jefferies, Sharon
2016-01-01
The material in this report covers the results on the NASA-wide TRA team, who are responsible for ascertaining the full extent of issues and ambiguities pertaining to TRATRL and to provide recommendations for mitigation. The team worked for approximately 6 months to become knowledgeable on the current TRATRL process and guidance and to derive recommendations for improvement.The team reviewed the TRA processes of other government agencies (OGA), including international agencies, and found that while the high-level processes are similar, the NASA process has a greater level of detail. Finally, NASA’s HQ OCT continues to monitor the GAO’s efforts to produce a TRA Best Practices Guide, a draft of which was received in February 2016. This Guide could impact the recommendations of this report.
Atkinson, Thomas M; Mendoza, Tito R; Sit, Laura; Passik, Steven; Scher, Howard I; Cleeland, Charles; Basch, Ethan
2010-03-01
In 2006, the United States Food and Drug Administration (FDA) released a draft Guidance for Industry on the use of patient-reported outcomes (PRO) Measures in Medical Product Development to Support Labeling Claims. This draft guidance outlines psychometric aspects that should be considered when designing a PRO measure, including conceptual framework, content validity, construct validity, reliability, and the ability to detect clinically meaningful score changes. When finalized, it may provide a blueprint for evaluations of PRO measures that can be considered by sponsors and investigators involved in PRO research and drug registration trials. In this review we examine the short form of the Brief Pain Inventory (BPI) and particularly the "pain at its worst in the last 24 hours" item in the context of the FDA draft guidance, to assess its utility in clinical trials that include pain as a PRO endpoint. After a systematic evaluation of the psychometric aspects of the BPI, we conclude that the BPI and its "pain at its worst in the last 24 hours" item generically satisfy most key recommendations outlined in the draft guidance for assessing a pain-reduction treatment effect. Nonetheless, when the BPI is being considered for assessment of pain endpoints in a registration trial, sponsors and investigators should consult with the appropriate FDA division early during research design to discuss whether there is sufficient precedent to use the instrument in the population of interest or whether additional evaluations of measurement properties are advisable.
Security Economics and European Policy
NASA Astrophysics Data System (ADS)
Anderson, Ross; Böhme, Rainer; Clayton, Richard; Moor, Tyler
In September 2007, we were awarded a contract by the European Network and Information Security Agency (ENISA) to investigate failures in the market for secure electronic communications within the European Union, and come up with policy recommendations. In the process, we spoke to a large number of stakeholders, and held a consultative meeting in December 2007 in Brussels to present draft proposals, which established most had wide stakeholder support. The formal outcome of our work was a detailed report, “Security Economics and the Internal Market”, published by ENISA in March 2008. This paper presents a much abridged version: in it, we present the recommendations we made, along with a summary of our reasoning.
Radon Dose Determination for Cave Guides in Czech Republic
NASA Astrophysics Data System (ADS)
Thinova, Lenka; Rovenska, Katerina
2008-08-01
According to recommended approach there are six (from total of twelve) open-to-public caves in Czech Republic, reaching near to an effective lung-dose of 6mSv/year. A conservative approach for estimating the potential effective lung-dose in caves (or underground) is based on two season's measurements, using solid state alpha track detector (Kodak in plastic diffusion chamber). The obtained dataset is converted into an annual effective dose, in agreement with the ICRP65 recommendation, using the "cave factor" 1.5. The value of "cave factor" which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached/attached ratio (6.5 : 93.5 for residential places, 13.6 : 86.4 for caves due to lower concentration of free aerosols) and on the equilibrium factor. Thus conversion factor is 1.5 times higher in comparison with ICRP 65. Is this correct? Because a more precisely determined dose value would have a significant impact on radon remedies, or on restricting the time workers stay underground, a series of measurement was initiated in 2003 with the aim to specify input data, computation and errors in effective dose assessment in each one of the evaluated caves separately. The enhancement of personal dosimetry for underground work places includes a study of the given questions, from the following points of view in each cave: continual radon measurement; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of free 218Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoil and in water inside/outside, a study of the radon sources in the cave; determination of the free fraction from continual unattached and attached fraction measurement (grid and filter); thoron measurement. Air flow measurements provide very interesting information about the origin of "radon pockets" with very high radon concentration, and enable study of the location of the radon supply and its transfer among individual areas of the cave. Most of the results show the equilibrium factor around F = 0.2-0.7 and the unattached fraction around 2%-30%. One of the most important question remains: how accurately was the unattached fraction measured? Part of this project was to verify the influence of etched track detector position in the cave.
2009-01-01
Background The International Commission on Radiological Protection (ICRP) recommended annual occupational dose limit is 20 mSv. Cancer mortality in Japanese A-bomb survivors exposed to less than 20 mSv external radiation in 1945 was analysed previously, using a latency model with non-linear dose response. Questions were raised regarding statistical inference with this model. Methods Cancers with over 100 deaths in the 0 - 20 mSv subcohort of the 1950-1990 Life Span Study are analysed with Poisson regression models incorporating latency, allowing linear and non-linear dose response. Bootstrap percentile and Bias-corrected accelerated (BCa) methods and simulation of the Likelihood Ratio Test lead to Confidence Intervals for Excess Relative Risk (ERR) and tests against the linear model. Results The linear model shows significant large, positive values of ERR for liver and urinary cancers at latencies from 37 - 43 years. Dose response below 20 mSv is strongly non-linear at the optimal latencies for the stomach (11.89 years), liver (36.9), lung (13.6), leukaemia (23.66), and pancreas (11.86) and across broad latency ranges. Confidence Intervals for ERR are comparable using Bootstrap and Likelihood Ratio Test methods and BCa 95% Confidence Intervals are strictly positive across latency ranges for all 5 cancers. Similar risk estimates for 10 mSv (lagged dose) are obtained from the 0 - 20 mSv and 5 - 500 mSv data for the stomach, liver, lung and leukaemia. Dose response for the latter 3 cancers is significantly non-linear in the 5 - 500 mSv range. Conclusion Liver and urinary cancer mortality risk is significantly raised using a latency model with linear dose response. A non-linear model is strongly superior for the stomach, liver, lung, pancreas and leukaemia. Bootstrap and Likelihood-based confidence intervals are broadly comparable and ERR is strictly positive by bootstrap methods for all 5 cancers. Except for the pancreas, similar estimates of latency and risk from 10 mSv are obtained from the 0 - 20 mSv and 5 - 500 mSv subcohorts. Large and significant cancer risks for Japanese survivors exposed to less than 20 mSv external radiation from the atomic bombs in 1945 cast doubt on the ICRP recommended annual occupational dose limit. PMID:20003238
Dental radiographic guidelines: a review.
Kim, Irene H; Mupparapu, Muralidhar
2009-05-01
The 2004 American Dental Association (ADA)/US Food and Drug Administration (FDA) radiographic selection criteria and guidelines were reviewed and compared with the prior radiographic selection criteria and guidelines. The authors reviewed the publications from the US FDA, US Department of Health and Human Services, and National Council on Radiation Protection and Measurements. The positions outlined by the Canadian Dental Association and the European Commission were also reviewed and compared to US guidelines. The FDA guidelines were first published in 1987, and several changes have been made to them over the years. Recent literature reveals that the general compliance of these guidelines is very low, especially within dental schools in the United States and Canada. Little is known about the compliance outside of the dental school environment; however, it is expected to be low for various reasons. In 2007, the International Commission on Radiological Protection (ICRP) revised its estimates of tissue radiosensitivity, which resulted in effective doses of dental radiographs 32% to 422% higher than the 1990 ICRP guidelines. Flow charts summarizing the latest guidelines were developed to facilitate general compliance among practitioners. Based on the literature reviewed and the recent ICRP findings, it would be prudent for dental health care professionals to follow dental radiographic guidelines.
Estimation of absorbed fraction to the anterior nose from inhaled beta emitters
NASA Astrophysics Data System (ADS)
Moussa, Hanna Moussa
2000-08-01
The main purpose of this research is to introduce a new and more realistic geometry for the anterior nose region (ET1) as an alternative to the one provided in ICRP Publication 66. For a more accurate estimation of electron absorbed fraction (AF) to the nuclei of basal cells in the ET 1 region, the proposed new geometry (frustum of a cone) replaces the cylinder geometry, which was used in ICRP 66. Since the electron absorbed fraction (AF) data in ICRP 66 are calculated based on the nose size for an adult Caucasian male, a second purpose of this research is to investigate how the nose size (different ethnic groups) and nose tissue composition (male, female and adolescent), affects the electron absorbed fraction values. The third aim of this research is to develop a Monte Carlo program to estimate the electron energies that emerge from the surface of spherical dust particles. Given that electrons can be located anywhere between the center and the surface of the sphere, we vary the sphere radius from 0.5 to 50 μm and investigate the effects of self-absorption on the emitted electron energies and absorbed fraction.
New Stochastic Annual Limits on Intake for Selected Radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
Annual limits on intake (ALI) have historically been tabulated by the International Commission on Radiological Protection (e.g., ICRP 1979, 1961) and also by the Environmental Protection Agency (EPA 1988). These compilations have been rendered obsolete by more recent ICRP dosimetry methods, and, rather than provide new ALIs, the ICRP has opted instead to provide committed dose coefficients from which an ALI can be determined by a user for a specific set of conditions. The U.S. Department of Energy historically has referenced compilations of ALIs and has defined their method of calculation in its radiation protection regulation (10 CFDR 835), butmore » has never provided a specific compilation. Under June 2007 amendments to 10 CFR 835, ALIs can be calculated by dividing an appropriate dose limit, either 5-rem (0.05 Sv) effective dose or 50 rem (0.5 Sv) equivalent dose to an individual organ or tissue, by an appropriate committed dose coefficient. When based on effective dose, the ALI is often referred to as a stochastic annual limit on intake (SALI), and when based on the individual organ or tissue equivalent limit, it has often been called a deterministic annual limit on intake (DALI).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.
1994-10-01
The unabridged data used in preparing ICRP Publication 38 (1983) and a monograph of the Medical Internal Radiation Dose (MIRD) Committee are now available in electronic form. The {open_quotes}ICRP38 collection{close_quotes} contains data on the energies and intensities of radiations emitted by 825 radionuclides (those in ICRP Publication 38 plus 13 from the MIRD monograph), and the {open_quotes}MIRD collection{close_quotes} contains data on 242 radionuclides. Each collection consists of a radiations data file and a beta spectra data file. The radiations data file contains the complete listing of the emitted radiations, their types, mean or unique energies, and absolute intensities for eachmore » radionuclide, the probability that a beta particle will be emitted with kinetic energies defined by a standard energy grid. Although summary information from the radiation data files has been published, neither the unabridged data nor the beta spectra have been published. These data files and a data extraction utility, which runs on a personal computer, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory. 13 refs., 1 fig., 6 tabs.« less
Harrison, John D.; Leggett, Richard Wayne
2016-01-01
This letter to the editor of Journal of Radiological Protection is in response to a letter to the editor from G. M. Smith and M. C. Thorne of Great Britain concerning the appropriate selection of dose coefficients for ingested carbon-14 and chlorine-36, two of the most important long-lived components of radioactive wastes. Smith and Thorne argue that current biokinetic models of the International Commission on Radiological Protection (ICRP) for carbon and chlorine are overly cautious models from the standpoint of radiation dose estimates for C-14 and Cl-36, and that more realistic models are needed for evaluation of the hazards ofmore » these radionuclides in nuclear wastes. We (Harrison and Leggett) point out that new biokinetic models for these and other elements (developed at ORNL) will soon appear in ICRP Publications. These new models generally are considerably more realistic than current ICRP models. Here, examples are given for C-14 inhaled as carbon dioxide or ingested in water as bicarbonate, carbonate, or carbon dioxide.« less
Puncher, M; Zhang, W; Harrison, J D; Wakeford, R
2017-06-26
Assessments of risk to a specific population group resulting from internal exposure to a particular radionuclide can be used to assess the reliability of the appropriate International Commission on Radiological Protection (ICRP) dose coefficients used as a radiation protection device for the specified exposure pathway. An estimate of the uncertainty on the associated risk is important for informing judgments on reliability; a derived uncertainty factor, UF, is an estimate of the 95% probable geometric difference between the best risk estimate and the nominal risk and is a useful tool for making this assessment. This paper describes the application of parameter uncertainty analysis to quantify uncertainties resulting from internal exposures to radioiodine by members of the public, specifically 1, 10 and 20-year old females from the population of England and Wales. Best estimates of thyroid cancer incidence risk (lifetime attributable risk) are calculated for ingestion or inhalation of 129 I and 131 I, accounting for uncertainties in biokinetic model and cancer risk model parameter values. These estimates are compared with the equivalent ICRP derived nominal age-, sex- and population-averaged estimates of excess thyroid cancer incidence to obtain UFs. Derived UF values for ingestion or inhalation of 131 I for 1 year, 10-year and 20-year olds are around 28, 12 and 6, respectively, when compared with ICRP Publication 103 nominal values, and 9, 7 and 14, respectively, when compared with ICRP Publication 60 values. Broadly similar results were obtained for 129 I. The uncertainties on risk estimates are largely determined by uncertainties on risk model parameters rather than uncertainties on biokinetic model parameters. An examination of the sensitivity of the results to the risk models and populations used in the calculations show variations in the central estimates of risk of a factor of around 2-3. It is assumed that the direct proportionality of excess thyroid cancer risk and dose observed at low to moderate acute doses and incorporated in the risk models also applies to very small doses received at very low dose rates; the uncertainty in this assumption is considerable, but largely unquantifiable. The UF values illustrate the need for an informed approach to the use of ICRP dose and risk coefficients.
Civilian End Strength Study. Study Sponsor ODCSLOG.
1985-12-30
Chief of Staff deferred action on the recommendations and requested a subsequent briefing with the following guidance. (1) Need to do more to take...Term Actions ... ..................... 38-39 ix CIVILIAN END STRENGTH STUDY Abstract This study examined the methodology by which the Army determines...DAPE-MBC) and COA ( DACA -OMP) has facilitated this process; an updated LOI, in draft, will clear up some of the problems identified in the test
1994-06-01
Army Navy ANF Army Navy Air Force ATI Air Transport Indicator BIT Built-in Test CVA Central Viewing Axis CIE Commission Internationale de l’Eclairage...up Time - Fighter ............................... 31 4.2.2.5 Warm-up time - Transport .............................. 32 4.2.3 Physical Characteristics...34 4.2.7 Transportability ............... ........... . 34 4.3 Design and Construction ............................ 34 4.3.1 Materials
ERIC Educational Resources Information Center
Pacific Region Educational Lab., Honolulu, HI.
The status of education in Enewetak, an island in the Republic of the Marshall Islands, is described in this report. Concern about the island's educational system was generated by the fact that none of the eighth-grade graduates had passed the government high school entrance exam since 1980. A visit made by a representative of the Pacific Region…
Genesee River Basin Study. Volume 1. Main Report.
1988-06-01
Watersheds" by the U.S. Department of Agriculture, Soil Conservation Service, was prepared in June and October 1974. The report entitled "Dyke Creek...Watershed Preliminary Evaluation" by the U.S. Department of Agriculture, Soil Conservation Service, was prepared in December 1974. The report recommended... Soil Conservation Service prepared the draft report "Dyke Creek, P.L. 566 Watershed Project, Watershed Plan and Environmental Assessment" in June
ERIC Educational Resources Information Center
Office of Science and Technology Policy, Washington, DC.
In this report, the National Information Infrastructure (NII) services issue is addressed, and activities to advance the development of NII services are recommended. The NII is envisioned to grow into a seamless web of communications networks, computers, databases, and consumer electronics that will put vast amounts of information at users'…
Treating the vulnerable in England and Wales: the impact of law reform and changing policy.
Glover-Thomas, N
2006-01-01
This article considers the role of treatment in the provision of mental health care in England and Wales. The current legislative position with regard to the making of treatment choices following compulsory commitment will be examined. Consideration will also be given to the position of the informal hospitalised patient, as in the case of R v. Bournewood Community and Mental Health NHS Trust, ex parte L and finally, the role of the common law in establishing (in)capacity in relation to the non-consensual provision of treatment for physical conditions. Attention will then be given to the reform process, which is currently ongoing in England and Wales, and its likely impact on treatment provision. The Mental Capacity Act 2005 received Royal Assent on the 7th April 2005, while the draft Mental Health Bill 2004 underwent detailed examination by the Joint Scrutiny Committee, a report of which was published on the 23rd March 2005. On the 13th July 2005 the British Government outlined its response following the publication of the Scrutiny Committee's recommendations and despite it accepting many of the recommendations put forward, some significant areas of concern remain making the draft Mental Health Bill 2004 "a long way from acceptable legislation".
[Recommendations for institutional response to an adverse event].
2016-01-01
The organizational response after an Adverse Event (AE) is critical for the patient recovery and trust restoration in the health system. It is also crucial for the involved caregiver psychological recovery. To design a frame of recommendations to help the healthcare services, institutions and organizations to provide a systematic approach to an AE. A reduced group of authors performed a non-systematic review of the literature and developed an initial draft. The draft was sent to the rest of authors, who suggested modifications in structure, content, references and style throughout successive manuscript versions until a final one was accepted. AE response includes the patient's clinical stabilization and a therapeutic plan to mitigate harm, the safeguard of used materials or health products involved, the appropriate disclosure to patient and family, the support of affected staff and their replacement if needed, the report to appropriate clinical and management heads, the event circumstances documentation and the starting of the AE investigation and analysis. Besides the professional, family and patient's trust and health recovery, the ultimate target of a correct AE response is the improvement of healthcare processes to prevent its repetition considering the AE as a system failure and learning and improving through its analysis. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Hum Na, Yong; Zhang, Binquan; Zhang, Juying; Caracappa, Peter F.; Xu, X. George
2010-07-01
Computational phantoms representing workers and patients are essential in estimating organ doses from various occupational radiation exposures and medical procedures. Nearly all existing phantoms, however, were purposely designed to match internal and external anatomical features of the Reference Man as defined by the International Commission on Radiological Protection (ICRP). To reduce uncertainty in dose calculations caused by anatomical variations, a new generation of phantoms of varying organ and body sizes is needed. This paper presents detailed anatomical data in tables and graphs that are used to design such size-adjustable phantoms representing a range of adult individuals in terms of the body height, body weight and internal organ volume/mass. Two different sets of information are used to derive the phantom sets: (1) individual internal organ size and volume/mass distribution data derived from the recommendations of the ICRP in Publications 23 and 89 and (2) whole-body height and weight percentile data from the National Health and Nutrition Examination Survey (NHANES 1999-2002). The NHANES height and weight data for 19 year old males and females are used to estimate the distributions of individuals' size, which is unknown, that corresponds to the ICRP organ and tissue distributions. This paper then demonstrates the usage of these anthropometric data in the development of deformable anatomical phantoms. A pair of phantoms—modeled entirely in mesh surfaces—of the adult male and female, RPI-adult male (AM) and RPI-adult female (AF) are used as the base for size-adjustable phantoms. To create percentile-specific phantoms from these two base phantoms, organ surface boundaries are carefully altered according to the tabulated anthropometric data. Software algorithms are developed to automatically match the organ volumes and masses with desired values. Finally, these mesh-based, percentile-specific phantoms are converted into voxel-based phantoms for Monte Carlo radiation transport simulations. This paper also compares absorbed organ doses for the RPI-AM-5th-height and -weight percentile phantom (165 cm in height and 56 kg in weight) and the RPI-AM-95th-height and -weight percentile phantom (188 cm in height and 110 kg in weight) with those for the RPI-AM-50th-height and -weight percentile phantom (176 cm in height and 73 kg in weight) from exposures to 0.5 MeV external photon beams. The results suggest a general finding that the phantoms representing a slimmer and shorter individual male received higher absorbed organ doses because of lesser degree of photon attenuation due to smaller amount of body fat. In particular, doses to the prostate and adrenal in the RPI-AM-5th-height and -weight percentile phantom is about 10% greater than those in the RPI-AM-50th-height and -weight percentile phantom approximating the ICRP Reference Man. On the other hand, the doses to the prostate and adrenal in the RPI-AM-95th-height and -weight percentile phantom are approximately 20% greater than those in the RPI-AM-50th-height and -weight percentile phantom. Although this study only considered the photon radiation of limited energies and irradiation geometries, the potential to improve the organ dose accuracy using the deformable phantom technology is clearly demonstrated.
Na, Yong Hum; Zhang, Binquan; Zhang, Juying; Caracappa, Peter F; Xu, X George
2012-01-01
Computational phantoms representing workers and patients are essential in estimating organ doses from various occupational radiation exposures and medical procedures. Nearly all existing phantoms, however, were purposely designed to match internal and external anatomical features of the Reference Man as defined by the International Commission on Radiological Protection (ICRP). To reduce uncertainty in dose calculations caused by anatomical variations, a new generation of phantoms of varying organ and body sizes is needed. This paper presents detailed anatomical data in tables and graphs that are used to design such size-adjustable phantoms representing a range of adult individuals in terms of the body height, body weight and internal organ volume/mass. Two different sets of information are used to derive the phantom sets: (1) individual internal organ size and volume/mass distribution data derived from the recommendations of the ICRP in Publications 23 and 89 and (2) whole-body height and weight percentile data from the National Health and Nutrition Examination Survey (NHANES 1999–2002). The NHANES height and weight data for 19 year old males and females are used to estimate the distributions of individuals’ size, which is unknown, that corresponds to the ICRP organ and tissue distributions. This paper then demonstrates the usage of these anthropometric data in the development of deformable anatomical phantoms. A pair of phantoms—modeled entirely in mesh surfaces—of the adult male and female, RPI-adult male (AM) and RPI-adult female (AF) are used as the base for size-adjustable phantoms. To create percentile-specific phantoms from these two base phantoms, organ surface boundaries are carefully altered according to the tabulated anthropometric data. Software algorithms are developed to automatically match the organ volumes and masses with desired values. Finally, these mesh-based, percentile-specific phantoms are converted into voxel-based phantoms for Monte Carlo radiation transport simulations. This paper also compares absorbed organ doses for the RPI-AM-5th-height and -weight percentile phantom (165 cm in height and 56 kg in weight) and the RPI-AM-95th-height and -weight percentile phantom (188 cm in height and 110 kg in weight)with those for theRPI-AM-50th-height and -weight percentile phantom (176 cm in height and 73 kg in weight) from exposures to 0.5 MeV external photon beams. The results suggest a general finding that the phantoms representing a slimmer and shorter individual male received higher absorbed organ doses because of lesser degree of photon attenuation due to smaller amount of body fat. In particular, doses to the prostate and adrenal in the RPI-AM-5th-height and -weight percentile phantom is about 10% greater than those in the RPI-AM-50th-height and -weight percentile phantom approximating the ICRP Reference Man. On the other hand, the doses to the prostate and adrenal in the RPI-AM-95th-height and -weight percentile phantom are approximately 20% greater than those in the RPI-AM-50th-height and -weight percentile phantom. Although this study only considered the photon radiation of limited energies and irradiation geometries, the potential to improve the organ dose accuracy using the deformable phantom technology is clearly demonstrated. PMID:20551505
Brazilian recommendations of mechanical ventilation 2013. Part 2
2014-01-01
Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumologia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document. PMID:25410835
Brazilian recommendations of mechanical ventilation 2013. Part I
Barbas, Carmen Sílvia Valente; Ísola, Alexandre Marini; Farias, Augusto Manoel de Carvalho; Cavalcanti, Alexandre Biasi; Gama, Ana Maria Casati; Duarte, Antonio Carlos Magalhães; Vianna, Arthur; Serpa, Ary; Bravim, Bruno de Arruda; Pinheiro, Bruno do Valle; Mazza, Bruno Franco; de Carvalho, Carlos Roberto Ribeiro; Toufen, Carlos; David, Cid Marcos Nascimento; Taniguchi, Corine; Mazza, Débora Dutra da Silveira; Dragosavac, Desanka; Toledo, Diogo Oliveira; Costa, Eduardo Leite; Caser, Eliana Bernardete; Silva, Eliezer; Amorim, Fabio Ferreira; Saddy, Felipe; Galas, Filomena Regina Barbosa Gomes; Silva, Gisele Sampaio; de Matos, Gustavo Faissol Janot; Emmerich, João Claudio; Valiatti, Jorge Luis dos Santos; Teles, José Mario Meira; Victorino, Josué Almeida; Ferreira, Juliana Carvalho; Prodomo, Luciana Passuello do Vale; Hajjar, Ludhmila Abrahão; Martins, Luiz Cláudio; Malbouisson, Luiz Marcelo Sá; Vargas, Mara Ambrosina de Oliveira; Reis, Marco Antonio Soares; Amato, Marcelo Brito Passos; Holanda, Marcelo Alcântara; Park, Marcelo; Jacomelli, Marcia; Tavares, Marcos; Damasceno, Marta Cristina Paulette; Assunção, Murillo Santucci César; Damasceno, Moyzes Pinto Coelho Duarte; Youssef, Nazah Cherif Mohamad; Teixeira, Paulo José Zimmermann; Caruso, Pedro; Duarte, Péricles Almeida Delfino; Messeder, Octavio; Eid, Raquel Caserta; Rodrigues, Ricardo Goulart; de Jesus, Rodrigo Francisco; Kairalla, Ronaldo Adib; Justino, Sandra; Nemer, Sérgio Nogueira; Romero, Simone Barbosa; Amado, Verônica Moreira
2014-01-01
Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumologia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document. PMID:25028944
Brazilian recommendations of mechanical ventilation 2013. Part 2
Barbas, Carmen Sílvia Valente; Ísola, Alexandre Marini; Farias, Augusto Manoel de Carvalho; Cavalcanti, Alexandre Biasi; Gama, Ana Maria Casati; Duarte, Antonio Carlos Magalhães; Vianna, Arthur; Serpa Neto, Ary; Bravim, Bruno de Arruda; Pinheiro, Bruno do Valle; Mazza, Bruno Franco; de Carvalho, Carlos Roberto Ribeiro; Toufen Júnior, Carlos; David, Cid Marcos Nascimento; Taniguchi, Corine; Mazza, Débora Dutra da Silveira; Dragosavac, Desanka; Toledo, Diogo Oliveira; Costa, Eduardo Leite; Caser, Eliana Bernadete; Silva, Eliezer; Amorim, Fabio Ferreira; Saddy, Felipe; Galas, Filomena Regina Barbosa Gomes; Silva, Gisele Sampaio; de Matos, Gustavo Faissol Janot; Emmerich, João Claudio; Valiatti, Jorge Luis dos Santos; Teles, José Mario Meira; Victorino, Josué Almeida; Ferreira, Juliana Carvalho; Prodomo, Luciana Passuello do Vale; Hajjar, Ludhmila Abrahão; Martins, Luiz Claudio; Malbouisson, Luis Marcelo Sá; Vargas, Mara Ambrosina de Oliveira; Reis, Marco Antonio Soares; Amato, Marcelo Brito Passos; Holanda, Marcelo Alcântara; Park, Marcelo; Jacomelli, Marcia; Tavares, Marcos; Damasceno, Marta Cristina Paulette; Assunção, Murillo Santucci César; Damasceno, Moyzes Pinto Coelho Duarte; Youssef, Nazah Cherif Mohamed; Teixeira, Paulo José Zimmermann; Caruso, Pedro; Duarte, Péricles Almeida Delfino; Messeder, Octavio; Eid, Raquel Caserta; Rodrigues, Ricardo Goulart; de Jesus, Rodrigo Francisco; Kairalla, Ronaldo Adib; Justino, Sandra; Nemer, Sergio Nogueira; Romero, Simone Barbosa; Amado, Verônica Moreira
2014-01-01
Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumologia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document. PMID:25295817
Guidelines for research on drugged driving
Walsh, J. Michael; Verstraete, Alain G.; Huestis, Marilyn A.; Mørland, Jørg
2009-01-01
Aim A major problem in assessing the true public health impact of drug-use on driving and overall traffic safety is that the variables being measured across studies vary significantly. In studies reported in a growing global literature, basic parameters assessed, analytical techniques and drugs tested are simply not comparable due to lack of standardization in the field. These shortcomings severely limit the value of this research to add knowledge to the field. A set of standards to harmonize research findings is sorely needed. This project was initiated by several international organizations to develop guidelines for research on drugged driving. Methods A September 2006 meeting of international experts discussed the harmonization of protocols for future research on drugged driving. The principal objective of the meeting was to develop a consensus report setting guidelines, standards, core data variables and other controls that would form the basis for future international research. A modified Delphi method was utilized to develop draft guidelines. Subsequently, these draft guidelines were posted on the internet for global review, and comments received were integrated into the final document. Results The Guidelines Document is divided into three major sections, each focusing upon different aspects of drugged driving research (e.g. roadside surveys, prevalence studies, hospital studies, fatality and crash investigations, etc.) within the critical issue areas of ‘behavior’, ‘epidemiology’ and ‘toxicology’. The behavioral section contains 32 specific recommendations; (2) epidemiology 40 recommendations; and (3) toxicology 64 recommendations. Conclusions It is anticipated that these guidelines will improve significantly the overall quality of drugged driving research and facilitate future cross-study comparisons nationally and globally. PMID:18855814
Brazilian recommendations of mechanical ventilation 2013. Part I
2014-01-01
Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumologia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document. PMID:25210957
Simões-Araújo, Jean Luiz; Leite, Jakson; Marie Rouws, Luc Felicianus; Passos, Samuel Ribeiro; Xavier, Gustavo Ribeiro; Rumjanek, Norma Gouvêa; Zilli, Jerri Édson
The strain BR 3262 was isolated from nodule of cowpea (Vigna unguiculata L. Walp) growing in soil of the Atlantic Forest area in Brazil and it is reported as an efficient nitrogen fixing bacterium associated to cowpea. Firstly, this strain was assigned as Bradyrhizobium elkanii, however, recently a more detailed genetic and molecular characterization has indicated it could be a Bradyrhizobium pachyrhizi species. We report here the draft genome sequence of B. pachyrhizi strain BR 3262, an elite bacterium used as inoculant for cowpea. The whole genome with 116 scaffolds, 8,965,178bp and 63.8% of C+G content for BR 3262 was obtained using Illumina MiSeq sequencing technology. Annotation was added by the RAST prokaryotic genome annotation service and shown 8369 coding sequences, 52 RNAs genes, classified in 504 subsystems. Published by Elsevier Editora Ltda.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1985-12-31
In 1982, the Congress enacted the Nuclear Waste Policy Act (Public Law 97-425), which established a comprehensive national program directed toward siting, constructing, and operating geologic repositories for the permanent disposal of high-level radioactive waste. In February 1983, the United States Department of Energy (DOE) identified the nine referenced repository locations as potentially acceptable sites for a mined geologic repository. These sites have been evaluated in accordance with the DOE`s General Guidelines for the Recommendation of Sites for Nuclear Waste Repositories. The DOE findings and determinations are based on the evaluations contained in the draft Environmental Assessments (EA). A finalmore » EA will be prepared after considering the comments received on the draft EA. The purpose of this document is to provide the public with specific site information on each potential repository location.« less
Evaluation in industry of a draft code of practice for manual handling.
Ashby, Liz; Tappin, David; Bentley, Tim
2004-05-01
This paper reports findings from a study which evaluated the draft New Zealand Code of Practice for Manual Handling. The evaluation assessed the ease of use, applicability and validity of the Code and in particular the associated manual handling hazard assessment tools, within New Zealand industry. The Code was studied in a sample of eight companies from four sectors of industry. Subjective feedback and objective findings indicated that the Code was useful, applicable and informative. The manual handling hazard assessment tools incorporated in the Code could be adequately applied by most users, with risk assessment outcomes largely consistent with the findings of researchers using more specific ergonomics methodologies. However, some changes were recommended to the risk assessment tools to improve usability and validity. The evaluation concluded that both the Code and the tools within it would benefit from simplification, improved typography and layout, and industry-specific information on manual handling hazards.
Clinical guidelines for the treatment of depressive disorders. II. Principles of management.
Reesal, R T; Lam, R W
2001-06-01
The Canadian Psychiatric Association and the Canadian Network for Mood and Anxiety Treatments partnered to produce clinical guidelines for psychiatrists for the treatment of depressive disorders. A standard guidelines development process was followed. Relevant literature was identified using a computerized Medline search supplemented by review of bibliographies. Operational criteria were used to rate the quality of scientific evidence, and the line of treatment recommendations included consensus clinical opinion. This section on "Principles of Management" is 1 of 7 articles drafted and reviewed by clinicians. Revised drafts underwent national and international expert peer review. The principles and goals of psychiatric management with psychotherapy and pharmacotherapy are reviewed. Two phases of treatment, acute and maintenance, are identified. Special topics, including inpatient management, suicide management, and medical-legal issues are also discussed. These principles of psychiatric management provide a framework for the use of specific treatments for depressive disorders.
Dosimetric assessment from 212Pb inhalation at a thorium purification plant.
Campos, M P; Pecequilo, B R S
2004-01-01
At the Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, there is a facility (thorium purification plant) where materials with high thorium concentrations are manipulated. In order to estimate afterwards the lung cancer risk for the workers, the thoron daughter (212Pb) levels were assessed and the committed effective and lung committed equivalent doses for workers in place. A total of 28 air filter samples were measured by total alpha counting through the modified Kusnetz method, to determine the 212Pb concentraion. The committed effective dose and lung committed equivalent dose due to 212Pb inhalation were derived from compartmental analysis following the ICRP 66 lung compartmental model, and ICRP 67 lead metabolic model.
ICRP Publication 125: Radiological Protection in Security Screening.
Cool, D A; Lazo, E; Tattersall, P; Simeonov, G; Niu, S
2014-07-01
The use of technologies to provide security screening for individuals and objects has been increasing rapidly, in keeping with the significant increase in security concerns worldwide. Within the spectrum of technologies, the use of ionizing radiation to provide backscatter and transmission screening capabilities has also increased. The Commission has previously made a number of statements related to the general topic of deliberate exposures of individuals in non-medical settings. This report provides advice on how the radiological protection principles recommended by the Commission should be applied within the context of security screening. More specifically, the principles of justification, optimisation of protection, and dose limitation for planned exposure situations are directly applicable to the use of ionising radiation in security screening. In addition, several specific topics are considered in this report, including the situation in which individuals may be exposed because they are concealed (‘stowaways’) in a cargo container or conveyance that may be subject to screening. The Commission continues to recommend that careful justification of screening should be considered before decisions are made to employ the technology. If a decision is made that its use is justified, the framework for protection as a planned exposure situation should be employed, including optimization of protection with the use of dose constraints and the appropriate provisions for authorisation and inspection.
Martin-Gill, Christian; Higgins, J Stephen; Van Dongen, Hans P A; Buysse, Daniel J; Thackery, Ronald W; Kupas, Douglas F; Becker, David S; Dean, Bradley E; Lindbeck, George H; Guyette, Francis X; Penner, Josef H; Violanti, John M; Lang, Eddy S; Patterson, P Daniel
2018-02-15
Performance measures are a key component of implementation, dissemination, and evaluation of evidence-based guidelines (EBGs). We developed performance measures for Emergency Medical Services (EMS) stakeholders to enable the implementation of guidelines for fatigue risk management in the EMS setting. Panelists associated with the Fatigue in EMS Project, which was supported by the National Highway Traffic Safety Administration (NHTSA), used an iterative process to develop a draft set of performance measures linked to 5 recommendations for fatigue risk management in EMS. We used a cross-sectional survey design and the Content Validity Index (CVI) to quantify agreement among panelists on the wording and content of draft measures. An anonymous web-based tool was used to solicit the panelists' perceptions of clarity and relevance of draft measures. Panelists rated the clarity and relevance separately for each draft measure on a 4-point scale. CVI scores ≥0.78 for clarity and relevance were specified a priori to signify agreement and completion of measurement development. Panelists judged 5 performance measures for fatigue risk management as clear and relevant. These measures address use of fatigue and/or sleepiness survey instruments, optimal duration of shifts, access to caffeine as a fatigue countermeasure, use of napping during shift work, and the delivery of education and training on fatigue risk management for EMS personnel. Panelists complemented performance measures with suggestions for implementation by EMS agencies. Performance measures for fatigue risk management in the EMS setting will facilitate the implementation and evaluation of the EBG for Fatigue in EMS.
Review of the Draft 2014 Science Mission Directorate Science Plan
NASA Technical Reports Server (NTRS)
2013-01-01
At the request of NASA's Science Mission Directorate (SMD), the National Research Council's (NRC's) Space Studies Board (SSB) initiated a study to review a draft of the SMD's 2014 Science Plan. The request for this review was made at a time when NASA is engaged in the final stages of a comprehensive, agency-wide effort to develop a new strategic plan and at a time when NASA's budget is under considerable stress. SMD's Science Plan serves to provide more detail on its four traditional science disciplines-astronomy and astrophysics, solar and space physics (also called heliophysics), planetary science, and Earth remote sensing and related activities-than is possible in the agency-wide Strategic Plan. In conducting its review of the draft Science Plan, the Committee on the Assessment of the NASA Science Mission Directorate 2014 Science Plan was charged to comment on the following specific areas: (1) Responsiveness to the NRC's guidance on key science issues and opportunities in recent NRC reports; (2) Attention to interdisciplinary aspects and overall scientific balance; (3) Identification and exposition of important opportunities for partnerships as well as education and public outreach; (4) Integration of technology development with the science program; (5) Clarity on how the plan aligns with SMD's strategic planning process; (6) General readability and clarity of presentation; and (7) Other relevant issues as determined by the committee. The main body of the report provides detailed findings and recommendations relating to the draft Science Plan. The highest-level, crosscutting issues are summarized here, and more detail is available in the main body of the report.
1982-06-01
these conditions . Therefore, the no-action plan is not being recommended. With the present channel conditions and anticipated slow growth for... conditions very similar to those of today. No ocean disposal is anticipated. Because no significant growth in socioeconomic activity is expected without...accuracy; however, project construction provides conditions favorable for growth . The service industry would be expected to closely follow any increase
Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, P.A.
1994-06-01
Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and redmore » marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from tissue activities, ranged from 7-20 mSv y{sup {minus}1} using human weighting factors for comparison to human doses only. Effective doses to northern Canadians and wildlife were, respectively, 7-11% and 1.8-5 times an estimated human background of 4 mSv y{sup {minus}} from all sources. 51 refs., 2 figs., 9 tabs.« less
NASA Astrophysics Data System (ADS)
Villoing, Daphnée; Marcatili, Sara; Garcia, Marie-Paule; Bardiès, Manuel
2017-03-01
The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model proposed by the International Commission on Radiological Protection in ICRP report 110. Monoenergetic photons and electrons (from 50 keV to 2 MeV) and four isotopes currently used in nuclear medicine (fluorine-18, lutetium-177, iodine-131 and yttrium-90) were investigated. Absorbed fractions, specific absorbed fractions and S-values were generated with GATE and MCNPX for 12 regions of interest in the ICRP 110 female computational model, thereby leading to 144 source/target pair configurations. Relative differences between GATE and MCNPX obtained in specific configurations (self-irradiation or cross-irradiation) are presented. Relative differences in absorbed fractions, specific absorbed fractions or S-values are below 10%, and in most cases less than 5%. Dosimetric results generated with GATE for the 12 volumes of interest are available as supplemental data. GATE can be safely used for radiopharmaceutical dosimetry at the clinical scale. This makes GATE a viable option for Monte Carlo modelling of both imaging and absorbed dose in nuclear medicine.
Positional bias in variant calls against draft reference assemblies.
Briskine, Roman V; Shimizu, Kentaro K
2017-03-28
Whole genome resequencing projects may implement variant calling using draft reference genomes assembled de novo from short-read libraries. Despite lower quality of such assemblies, they allowed researchers to extend a wide range of population genetic and genome-wide association analyses to non-model species. As the variant calling pipelines are complex and involve many software packages, it is important to understand inherent biases and limitations at each step of the analysis. In this article, we report a positional bias present in variant calling performed against draft reference assemblies constructed from de Bruijn or string overlap graphs. We assessed how frequently variants appeared at each position counted from ends of a contig or scaffold sequence, and discovered unexpectedly high number of variants at the positions related to the length of either k-mers or reads used for the assembly. We detected the bias in both publicly available draft assemblies from Assemblathon 2 competition as well as in the assemblies we generated from our simulated short-read data. Simulations confirmed that the bias causing variants are predominantly false positives induced by reads from spatially distant repeated sequences. The bias is particularly strong in contig assemblies. Scaffolding does not eliminate the bias but tends to mitigate it because of the changes in variants' relative positions and alterations in read alignments. The bias can be effectively reduced by filtering out the variants that reside in repetitive elements. Draft genome sequences generated by several popular assemblers appear to be susceptible to the positional bias potentially affecting many resequencing projects in non-model species. The bias is inherent to the assembly algorithms and arises from their particular handling of repeated sequences. It is recommended to reduce the bias by filtering especially if higher-quality genome assembly cannot be achieved. Our findings can help other researchers to improve the quality of their variant data sets and reduce artefactual findings in downstream analyses.
NANOTECHNOLOGY WHITE PAPER | Science Inventory | US ...
Nanotechnology is the science of manipulating materials at the atomic and molecular level to develop new or enhanced materials and products. In December 2004, EPA’s Science Policy Council created a cross-Agency workgroup to identify and describe the issues EPA must address to ensure protection of human health and the environment as this new technology is developed. The draft white paper on nanotechnology is the product of the workgroup. The draft white paper describes the technology, and provides a discussion of the potential environmental benefits of nanotechnology and its applications that can foster sustainable use of resources. Risk management issues and the Agency’s statutory mandates are outlined, followed by an extensive discussion of risk assessment issues. The paper identifies research needs for both environmental applications and implications of nanotechnology and concludes with recommendations on next steps for addressing science policy issues and research needs. Supplemental information is provided in a number of appendices. The Agency will use the white paper to address research needs and risk assessment issues concerning nanotechnology. The draft white paper will undergo independent expert review, which will be conducted in the February time frame. All public comments received by January 31, 2006 will be submitted to the external review panel for their consideration. Comments received beyond that time will be considered by EPA. Follo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pappas, D; Reis, S; Ali, A
Purpose To determine how consistent the results of different raters are when reviewing the same cases within the Radiation Oncology Incident Learning System (ROILS). Methods Three second-year medical physics graduate students filled out incident reports in spreadsheets set up to mimic ROILS. All students studied the same 33 cases and independently entered their assessments, for a total of 99 reviewed cases. The narratives for these cases were obtained from a published International Commission on Radiological Protection (ICRP) report which included shorter narratives selected from the Radiation Oncology Safety Information System (ROSIS) database. Each category of questions was reviewed to seemore » how consistent the results were by utilizing free-marginal multirater kappa analysis. The percentage of cases where all raters shared full agreement or full disagreement was recorded to show which questions were answered consistently by multiple raters for a given case. The consistency among the raters was analyzed between ICRP and ROSIS cases to see if either group led to more reliable results. Results The categories where all raters agreed 100 percent in their choices were the event type (93.94 percent of cases 0.946 kappa) and the likelihood of the event being harmful to the patient (42.42 percent of cases 0.409 kappa). The categories where all raters disagreed 100 percent in their choices were the dosimetric severity scale (39.39 percent of cases 0.139 kappa) and the potential future toxicity (48.48 percent of cases 0.205 kappa). ROSIS had more cases where all raters disagreed than ICRP (23.06 percent of cases compared to 15.58 percent, respectively). Conclusion Despite reviewing the same cases, the results among the three raters was widespread. ROSIS narratives were shorter than ICRP, which suggests that longer narratives lead to more consistent results. This study shows that the incident reporting system can be optimized to yield more consistent results.« less
Greiter, Matthias B; Giussani, Augusto; Höllriegl, Vera; Li, Wei Bo; Oeh, Uwe
2011-09-01
Biokinetic models describing the uptake, distribution and excretion of trace elements are an essential tool in nutrition, toxicology, or internal dosimetry of radionuclides. Zirconium, especially its radioisotope (95)Zr, is relevant to radiation protection due to its production in uranium fission and neutron activation of nuclear fuel cladding material. We present a comprehensive set of human data from a tracer study with stable isotopes of zirconium. The data are used to refine a biokinetic model of zirconium. Six female and seven male healthy adult volunteers participated in the study. It includes 16 complete double tracer investigations with oral ingestion and intravenous injection, and seven supplemental investigations. Tracer concentrations were measured in blood plasma and urine collected up to 100 d after tracer administration. The four data sets (two chemical tracer forms in plasma and urine) each encompass 105-240 measured concentration values above detection limits. Total fractional absorption of ingested zirconium was found to be 0.001 for zirconium in citrate-buffered drinking solution and 0.007 for zirconium oxalate solution. Biokinetic models were developed based on the linear first-order kinetic compartmental model approach used by the International Commission on Radiological Protection (ICRP). The main differences of the optimized systemic model of zirconium to the current ICRP model are (1) recycling into the transfer compartment made necessary by the observed tracer clearance from plasma, (2) different parameters related to fractional absorption for each form of the ingested tracer, and (3) a physiologically based excretion pathway to urine. The study considerably expands the knowledge on the biokinetics of zirconium, which was until now dominated by data from animal studies. The proposed systemic model improves the existing ICRP model, yet is based on the same principles and fits well into the ICRP radiation protection approach. Copyright © 2011 Elsevier B.V. All rights reserved.
Clavien, Pierre-Alain; Lesurtel, Mickael; Bossuyt, Patrick M M; Gores, Gregory J; Langer, Bernard; Perrier, Arnaud
2012-01-01
Although liver transplantation is a widely accepted treatment for hepatocellular carcinoma (HCC), much controversy remains and there is no generally accepted set of guidelines. An international consensus conference was held on Dec 2–4, 2010, in Zurich, Switzerland, with the aim of reviewing current practice regarding liver transplantation in patients with HCC and to develop internationally accepted statements and guidelines. The format of the conference was based on the Danish model. 19 working groups of experts prepared evidence-based reviews according to the Oxford classification, and drafted recommendations answering 19 specific questions. An independent jury of nine members was appointed to review these submissions and make final recommendations, after debates with the experts and audience at the conference. This report presents the final 37 statements and recommendations, covering assessment of candidates for liver transplantation, criteria for listing in cirrhotic and non-cirrhotic patients, role of tumour downstaging, management of patients on the waiting list, role of living donation, and post-transplant management. PMID:22047762
An Interim Report on NASA's Draft Space Technology Roadmaps
NASA Technical Reports Server (NTRS)
2011-01-01
NASA has developed a set of 14 draft roadmaps to guide the development of space technologies under the leadership of the NASA Office of the Chief Technologist (OCT). Each of these roadmaps focuses on a particular technology area (TA). The roadmaps are intended to foster the development of advanced technologies and concepts that address NASA's needs and contribute to other aerospace and national needs. OCT requested that the National Research Council conduct a study to review the draft roadmaps, gather and assess relevant community input, and make recommendations and suggest priorities to inform NASA's decisions as it finalizes its roadmaps. The statement of task states that "based on the results of the community input and its own deliberations, the steering committee will prepare a brief interim report that addresses high-level issues associated with the roadmaps, such as the advisability of modifying the number or technical focus of the draft NASA roadmaps." This interim report, which does not include formal recommendations, addresses that one element of the study charge. NASA requested this interim report so that it would have the opportunity to make an early start in modifying the draft roadmaps based on feedback from the panels and steering committee. The final report will address all other tasks in the statement of task. In particular, the final report will include a prioritization of technologies, will describe in detail the prioritization process and criteria, and will include specific recommendations on a variety of topics, including many of the topics mentioned in this interim report. In developing both this interim report and the final report to come, the steering committee draws on the work of six study panels organized by technical area, loosely following the organization of the 14 roadmaps, as follows: A Panel 1: Propulsion and Power TA01 Launch Propulsion Systems TA02 In-Space Propulsion Technologies TA03 Space Power and Energy Storage Systems TA13 Ground and Launch Systems Processing B Panel 2: Robotics, Communications, and Navigation TA04 Robotics, TeleRobotics, and Autonomous Systems TA05 Communication and Navigation Systems C Panel 3: Instruments and Computing TA08 Science Instruments, Observatories, and Sensor Systems TA11 Modeling, Simulation, Information Technology, and Data Processing D Panel 4: Human Health and Surface Exploration TA06 Human Health, Life Support, and Habitation Systems TA07 Human Exploration Destination Systems E Panel 5: Materials Panel TA10 Nanotechnology TA12 Materials, Structures, Mechanical Systems, and Manufacturing TA14 Thermal Management Systems F Panel 6: Entry, Descent, and Landing Panel TA09 Entry, Descent, and Landing Systems In addition to drawing on the expertise represented on the steering committee and panels, the committee obtained input from each of 14 public workshops held on each of the 14 roadmaps. At these 1-day workshops, invited speakers, guests, and members of the public engaged in discussions on the different technology areas and their value to NASA. Broad community input was also solicited from a public website, where more than 240 public comments were received on the draft roadmaps in response to application of criteria (such as benefit, risk and reasonableness, and alignment with NASA and national goals) that the steering committee established. This interim report reflects the results of deliberations by the steering committee in light of these public inputs as well as additional inputs from the six panels. The steering committee's final report will be completed early in 2012. That report will prioritize the technologies that span the entire scope of the 14 roadmaps and provide additional guidance on crosscutting themes and other relevant topics.
US Transuranium and Uranium Registries case study on accidental exposure to uranium hexafluoride.
Avtandilashvili, Maia; Puncher, Matthew; McComish, Stacey L; Tolmachev, Sergei Y
2015-03-01
The United States Transuranium and Uranium Registries' (USTUR) whole-body donor (Case 1031) was exposed to an acute inhalation of uranium hexafluoride (UF6) produced from an explosion at a uranium processing plant 65 years prior to his death. The USTUR measurements of tissue samples collected at the autopsy indicated long-term retention of inhaled slightly enriched uranium material (0.85% (235)U) in the deep lungs and thoracic lymph nodes. In the present study, the authors combined the tissue measurement results with historical bioassay data, and analysed them with International Commission on Radiological Protection (ICRP) respiratory tract models and the ICRP Publication 69 systemic model for uranium using maximum likelihood and Bayesian statistical methods. The purpose of the analysis was to estimate intakes and model parameter values that best describe the data, and evaluate their effect on dose assessment. The maximum likelihood analysis, which used the ICRP Publication 66 human respiratory tract model, resulted in a point estimate of 79 mg of uranium for the occupational intake composed of 86% soluble, type F material and 14% insoluble, type S material. For the Bayesian approach, the authors applied the Markov Chain Monte Carlo method, but this time used the revised human respiratory tract model, which is currently being used by ICRP to calculate new dose coefficients for workers. The Bayesian analysis estimated that the mean uranium intake was 160 mg, and calculated the case-specific lung dissolution parameters with their associated uncertainties. The parameters were consistent with the inhaled uranium material being predominantly soluble with a small but significant insoluble component. The 95% posterior range of the rapid dissolution fraction (the fraction of deposited material that is absorbed to blood rapidly) was 0.12 to 0.91 with a median of 0.37. The remaining fraction was absorbed slowly, with a 95% range of 0.000 22 d(-1) to 0.000 36 d(-1) and a median of 0.000 31 d(-1). The effective dose per unit intake calculated using the dissolution parameters derived from the maximum likelihood and the Bayesian analyses was higher than the current ICRP dose coefficient for type F uranium by a factor of 2 or 7, respectively; the higher value of the latter was due to use of the revised respiratory tract model. The dissolution parameter values obtained here may be more appropriate to use for radiation protection purposes when individuals are exposed to a UF6 mixture that contains an insoluble uranium component.
NASA Astrophysics Data System (ADS)
Sasaki, S.; Yamada, T.
2013-12-01
The great earthquake attacked the north-east area in Japan in March 11, 2011. The system of electrical facilities to control Fukushima Daiichi nuclear power station was completely destroyed by the following tsunamis. From the damaged reactor containment vessels, an amount of radioactive substances had leaked and been diffused in the vicinity of this station. Radiological internal exposure becomes a serious social issue both in Japan and all over the world. The present study provides an easily understandable, kinematic-based model to estimate the effective dose of radioactive substances in a human body by simplified the complicated mechanism of metabolism. International Commission on Radiological Protection (ICRP) has developed an exact model, which is well-known as a standard method to calculate the effective dose for radiological protection. However, owing to that the above method accord too much with the actual mechanism of metabolism in human bodies, it becomes rather difficult for non-professional people of radiology to gasp the whole images of the movement and the influences of radioactive substances in a human body. Therefore, in the present paper we propose a newly-derived and easily-understandable model to estimate the effective dose. The present method is very similar with the traditional and conventional hydrological tank model. Ingestion flux of radioactive substances corresponds to rain intensity and the storage of radioactive substances to the water storage in a basin in runoff analysis. The key of this method is to estimate the energy radiated from the radioactive nuclear disintegration of an atom by using classical theory of E. Fermi of beta decay and special relativity for various kinds of radioactive atoms. The parameters used in this study are only physical half-time and biological half-time, and there are no intentional and operational parameters of coefficients to adjust our theoretical runoff to observation of ICRP. Figure.1 compares time series of effective cesium-137 dose according to age calculated by ICRP software with calculated by the present method. Plots are calculated values by ICRP, the solid line is analytic solution given from the present method. It should be noted that the present study does not consider complicated mechanism, but it could give equally accurate results comparing to existing research. Time series of effective Cs-137 dose according to age when food contains 1 Bq/year is ingested for 1 year. (Plots are calculated values by ICRP. The solid line is analytic solution given from the present method)
Leenaars, P P; Hendriksen, C F; de Leeuw, W A; Carat, F; Delahaut, P; Fischer, R; Halder, M; Hanly, W C; Hartinger, J; Hau, J; Lindblad, E B; Nicklas, W; Outschoorn, I M; Stewart-Tull, D E
1999-01-01
This is the report of the thirty-fifth of a series of workshops organised by the European Centre for the Validation of Alternative Methods (ECVAM). ECVAM's main goal, as defined in 1993 by its Scientific Advisory Committee, is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine or replace the use of laboratory animals. One of the first priorities set by ECVAM was the implementation of procedures which would enable it to become well informed about the state-of-the-art of non-animal test development and validation, and the potential for the possible incorporation of alternative tests into regulatory procedures. It was decided that this would be best achieved by the organisation of ECVAM workshops on specific topics, at which small groups of invited experts would review the current status of various types of in vitro tests and their potential uses, and make recommendations about the best ways forward (1). This joint ECVAM/FELASA (Federation of European Laboratory Animal Science Associations) workshop on The Immunisation of Laboratory Animals for the Production of Polyclonal Antibodies was held in Utrecht (The Netherlands), on 20-22 March 1998, under the co-chairmanship of Coenraad Hendriksen (RIVM, Bilthoven, The Netherlands) and Wim de Leeuw (Inspectorate for Health Protection, The Netherlands). The participants, all experts in the fields of immunology, laboratory animal science, or regulation, came from universities, industry and regulatory bodies. The aims of the workshop were: a) to discuss and evaluate current immunisation procedures for the production of polyclonal antibodies (including route of injection, animal species and adjuvant ); and b) to draft recommendations and guidelines to improve the immunisation procedures, with regard both to animal welfare and to the optimisation of immunisation protocols. This report summarises the outcome of the discussions and includes a number of recommendations and a set of draft guidelines (included in Appendix 1). 1999 FRAME.
Care of girls and women with Turner syndrome: a guideline of the Turner Syndrome Study Group.
Bondy, Carolyn A
2007-01-01
The objective of this work is to provide updated guidelines for the evaluation and treatment of girls and women with Turner syndrome (TS). The Turner Syndrome Consensus Study Group is a multidisciplinary panel of experts with relevant clinical and research experience with TS that met in Bethesda, Maryland, April 2006. The meeting was supported by the National Institute of Child Health and unrestricted educational grants from pharmaceutical companies. The study group used peer-reviewed published information to form its principal recommendations. Expert opinion was used where good evidence was lacking. The study group met for 3 d to discuss key issues. Breakout groups focused on genetic, cardiological, auxological, psychological, gynecological, and general medical concerns and drafted recommendations for presentation to the whole group. Draft reports were available for additional comment on the meeting web site. Synthesis of the section reports and final revisions were reviewed by e-mail and approved by whole-group consensus. We suggest that parents receiving a prenatal diagnosis of TS be advised of the broad phenotypic spectrum and the good quality of life observed in TS in recent years. We recommend that magnetic resonance angiography be used in addition to echocardiography to evaluate the cardiovascular system and suggest that patients with defined cardiovascular defects be cautioned in regard to pregnancy and certain types of exercise. We recommend that puberty should not be delayed to promote statural growth. We suggest a comprehensive educational evaluation in early childhood to identify potential attention-deficit or nonverbal learning disorders. We suggest that caregivers address the prospect of premature ovarian failure in an open and sensitive manner and emphasize the critical importance of estrogen treatment for feminization and for bone health during the adult years. All individuals with TS require continued monitoring of hearing and thyroid function throughout the lifespan. We suggest that adults with TS be monitored for aortic enlargement, hypertension, diabetes, and dyslipidemia.
Corbel, Michael J; Das, Rose Gaines; Lei, Dianliang; Xing, Dorothy K L; Horiuchi, Yoshinobu; Dobbelaer, Roland
2008-04-07
This report reflects the discussion and conclusions of a WHO group of experts from National Regulatory Authorities (NRAs), National Control Laboratories (NCLs), vaccine industries and other relevant institutions involved in standardization and control of diphtheria, tetanus and pertussis vaccines (DTP), held on 20-21 July 2006 and 28-30 March 2007, in Geneva Switzerland for the revision of WHO Manual for quality control of DTP vaccines. Taking into account recent developments and standardization in quality control methods and the revision of WHO recommendations for D, T, P vaccines, and a need for updating the manual has been recognized. In these two meetings the current situation of quality control methods in terms of potency, safety and identity tests for DTP vaccines and statistical analysis of data were reviewed. Based on the WHO recommendations and recent validation of testing methods, the content of current manual were reviewed and discussed. The group agreed that the principles to be observed in selecting methods included identifying those critical for assuring safety, efficacy and quality and which were consistent with WHO recommendations/requirements. Methods that were well recognized but not yet included in current Recommendations should be taken into account. These would include in vivo and/or in vitro methods for determining potency, safety testing and identity. The statistical analysis of the data should be revised and updated. It was noted that the mouse based assays for toxoid potency were still quite widely used and it was desirable to establish appropriate standards for these to enable the results to be related to the standard guinea pig assays. The working group was met again to review the first drafts and to input further suggestions or amendments to the contributions of the drafting groups. The revised manual was to be finalized and published by WHO.
Xie, Tianwu; Zaidi, Habib
2016-12-01
Molecular imaging using PET and hybrid (PET/CT and PET/MR) modalities nowadays plays a pivotal role in the clinical setting for diagnosis and staging, treatment response monitoring, and radiation therapy treatment planning of a wide range of oncologic malignancies. The developing embryo/fetus presents a high sensitivity to ionizing radiation. Therefore, estimation of the radiation dose delivered to the embryo/fetus and pregnant patients from PET examinations to assess potential radiation risks is highly praised. We constructed eight embryo/fetus models at various gestation periods with 25 identified tissues according to reference data recommended by the ICRP publication 89 representing the anatomy of the developing embryo/fetus. The developed embryo/fetus models were integrated into realistic anthropomorphic computational phantoms of the pregnant female and used for estimating, using Monte Carlo calculations, S-values of common positron-emitting radionuclides, organ absorbed dose, and effective dose of a number of positron-emitting labeled radiotracers. The absorbed dose is nonuniformly distributed in the fetus. The absorbed dose of the kidney and liver of the 8-week-old fetus are about 47.45 % and 44.76 % higher than the average absorbed dose of the fetal total body for all investigated radiotracers. For 18 F-FDG, the fetal effective doses are 2.90E-02, 3.09E-02, 1.79E-02, 1.59E-02, 1.47E-02, 1.40E-02, 1.37E-02, and 1.27E-02 mSv/MBq at the 8th, 10th, 15th, 20th, 25th, 30th, 35th, and 38th weeks of gestation, respectively. The developed pregnant female/fetus models matching the ICRP reference data can be exploited by dedicated software packages for internal and external dose calculations. The generated S-values will be useful to produce new standardized dose estimates to pregnant patients and embryo/fetus from a variety of positron-emitting labeled radiotracers.
Gao, Bo; Li, Qiang; Zhou, Huai-Dong; Gao, Ji-Jun; Zou, Xiao-Wen; Yong, Huang
2014-05-01
The six heavy metal concentrations (Cr, Cr, As, Cd, Cu, Zn and Pb) in water samples collected from five reservoirs of Liao River Basin were studied. The health risk assessment for heavy metals pollution in reservoirs was conducted based on the environmental health risk assessment model recommended by U. S. Environmental Protection Agency. The results showed that the average concentrations of Cr, Cu, Zn, As, Cd and Pb in five reservoirs of Liao River Basin were 3.36, 1.03, 2. 70, 1.23, 0. 02 and 0. 03 microg L-1, respectively. In fact, these heavy metals concentrations were obviously lower than the Standard of National Drinking Water in China (GB 5749-2006). The results also showed that the metal carcinogenic risk was relatively high in this region. The order of the risk level of carcinogenic metals was Cr>As>Cd. The highest carcinogenic risk was from Cr, with the risk for adults ranging from 4. 50 X 10(-5) approximately 7. 53 X 10(-5) a-1' and the risk for children ranging from 6. 29 X 10(-5) to 1. 05 X 10(-4) a-1. The health risk levels caused by non-carcinogenic metals ranging from 10-13 to 10(-10) a-1 were lower than the acceptable range suggested by International Commission on Radiological Protection (ICRP) and the order of the risk level of non-carcinogenic metals was Cu>Zn>Pb. The total health risk of heavy metals for adults ranging from 1. 07X 10(-4) to 1. 72X 10(-4) a-1 and for children ranging from 1. 49 X 10(-4) to 2. 40 X 10(-4) a-1 exceeded the accepted level of 5 X 10(-5) a-1 as suggested by ICRP. The health risk levels of carcinogenic metals were significantly higher than those of non-carcinogenic metals in the reservoirs for Liao River Basin.
Sanusi, M S M; Ramli, A T; Hassan, W M S W; Lee, M H; Izham, A; Said, M N; Wagiran, H; Heryanshah, A
2017-07-01
Kuala Lumpur has been undergoing rapid urbanisation process, mainly in infrastructure development. The opening of new township and residential in former tin mining areas, particularly in the heavy mineral- or tin-bearing alluvial soil in Kuala Lumpur, is a contentious subject in land-use regulation. Construction practices, i.e. reclamation and dredging in these areas are potential to enhance the radioactivity levels of soil and subsequently, increase the existing background gamma radiation levels. This situation is worsened with the utilisation of tin tailings as construction materials apart from unavoidable soil pollutions due to naturally occurring radioactive materials in construction materials, e.g. granitic aggregate, cement and red clay brick. This study was conducted to assess the urbanisation impacts on background gamma radiation in Kuala Lumpur. The study found that the mean value of measured dose rate was 251±6nGyh -1 (156-392nGyh -1 ) and 4 times higher than the world average value. High radioactivity levels of 238 U (95±12Bqkg -1 ), 232 Th (191±23Bqkg -1 ,) and 40 K (727±130Bqkg -1 ) in soil were identified as the major source of high radiation exposure. Based on statistical ANOVA, t-test, and analyses of cumulative probability distribution, this study has statistically verified the dose enhancements in the background radiation. The effective dose was estimated to be 0.31±0.01mSvy -1 per man. The recommended ICRP reference level (1-20mSvy -1 ) is applicable to the involved existing exposure situation in this study. The estimated effective dose in this study is lower than the ICRP reference level and too low to cause deterministic radiation effects. Nevertheless based on estimations of lifetime radiation exposure risks, this study found that there was small probability for individual in Kuala Lumpur being diagnosed with cancer and dying of cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-12-01
In February 1983, the US Department of Energy (DOE) identified the Davis Canyon site in Utah, as one of nine potentially acceptable sites for a mined geologic repository for spent nuclear fuel and high-level radioactive waste. To determine their suitability, the Davis Canyon site and the eight other potentially acceptable sites have been evaluated in accordance with the DOE's General Guidelines for the Recommendation of Sites for Nuclear Waste Repositories. These evaluations are reported in this draft environmental assessment (EA), which is being issued for public review and comment. The DOE findings and determinations that are based on these evaluationsmore » are preliminary and subject to public review and comment. A final EA will be prepared after considering the comments received. On the basis of the evaluations reported in this draft EA, the DOE has found that the Davis Canyon site is not disqualified under the guidelines. The site is in the Paradox Basin, which is one of five distinct geohydrologic settings considered for the first repository. This setting contains one other potentially acceptable site - the Lavender Canyon site. Although the Lavender Canyon site appears to be suitable for site characterization, the DOE has concluded that the Davis Canyon site is the preferred site in the Paradox Basin. Furthermore, the DOE finds that the site is suitable for site characterization because the evidence does not support a conclusion that the site will not be able to meet each of the qualifying conditions specified in the guidelines. On the basis of these findings, the DOE is proposing to nominate the Davis Canyon site as one of five sites suitable for characterization. Having compared the Davis Canyon site with the other four sites proposed for nomination, the DOE has determined that the Davis Canyon site is not one of the three preferred sites for recommendation to the President as candidates for characterization.« less
Effective and organ doses from common CT examinations in one general hospital in Tehran, Iran
NASA Astrophysics Data System (ADS)
Khoramian, Daryoush; Hashemi, Bijan
2017-09-01
Purpose: It is well known that the main portion of artificial sources of ionizing radiation to human results from X-ray imaging techniques. However, reports carried out in various countries have indicated that most of their cumulative doses from artificial sources are due to CT examinations. Hence assessing doses resulted from CT examinations is highly recommended by national and international radiation protection agencies. The aim of this research has been to estimate the effective and organ doses in an average human according to 103 and 60 ICRP tissue weighting factor for six common protocols of Multi-Detector CT (MDCT) machine in a comprehensive training general hospital in Tehran/Iran. Methods: To calculate the patients' effective dose, the CT-Expo2.2 software was used. Organs/tissues and effective doses were determined for about 20 patients (totally 122 patients) for every one of six typical CT protocols of the head, neck, chest, abdomen-pelvis, pelvis and spine exams. In addition, the CT dosimetry index (CTDI) was measured in the standard 16 and 32 cm phantoms by using a calibrated pencil ionization chamber for the six protocols and by taking the average value of CT scan parameters used in the hospital compared with the CTDI values displayed on the console device of the machine. Results: The values of the effective dose based on the ICRP 103 tissue weighting factor were: 0.6, 2.0, 3.2, 4.2, 2.8, and 3.9 mSv and based on the ICRP 60 tissue weighting factor were: 0.9, 1.4, 3, 7.9, 4.8 and 5.1 mSv for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams respectively. Relative differences between those values were -22, 21, 23, -6, -31 and 16 percent for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams, respectively. The average value of CTDIv calculated for each protocol was: 27.32 ± 0.9, 18.08 ± 2.0, 7.36 ± 2.6, 8.84 ± 1.7, 9.13 ± 1.5, 10.42 ± 0.8 mGy for the head, neck, chest, abdomen-pelvis and spine CT exams, respectively. Conclusions: The highest organ doses delivered by various CT exams were received by brain (15.5 mSv), thyroid (19.00 mSv), lungs (9.3 mSv) and bladder (9.9 mSv), bladder (10.4 mSv), stomach (10.9 mSv) in the head, neck, chest, and the abdomen-pelvis, pelvis, and spine respectively. Except the neck and spine CT exams showing a higher effective dose compared to that reported in Netherlands, other exams indicated lower values compared to those reported by any other country.
Dose Limits for Man do not Adequately Protect the Ecosystem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higley, Kathryn A.; Alexakhin, Rudolf M.; McDonald, Joseph C.
2004-08-01
It has been known for quite some time that different organisms display differing degrees of sensitivity to the effects of ionizing radiations. Some microorganisms such as the bacterium Micrococcus radiodurans, along with many species of invertebrates, are extremely radio-resistant. Humans might be categorized as being relatively sensitive to radiation, and are a bit more resistant than some pine trees. Therefore, it could be argued that maintaining the dose limits necessary to protect humans will also result in the protection of most other species of flora and fauna. This concept is usually referred to as the anthropocentric approach. In other words,more » if man is protected then the environment is also adequately protected. The ecocentric approach might be stated as; the health of humans is effectively protected only when the environment is not unduly exposed to radiation. The ICRP is working on new recommendations dealing with the protection of the environment, and this debate should help to highlight a number of relevant issues concerning that topic.« less
NASA Astrophysics Data System (ADS)
Liu, Yi-Chi; Chuang, Keh-Shih; Yu, Cheng-Ching; Chao, Jiunn-Hsing; Hsu, Fang-Yuh
2015-11-01
Modern dental X-ray examination that consists of traditional form, panorama, and cone-beamed 3D technologies is one of the most frequent diagnostic applications nowadays. This study used the Rando Phantom and thermoluminescence dosimeters (TLD) to measure the absorbed doses of radiosensitive organs recommended by International Commission on Radiological Protection (ICRP), and whole body effective doses which were delivered due to dental X-ray examination performed with different types of X-ray instrument. Besides, enamel samples which performed reading with Electronic Paramagnetic Resonance (EPR) procedure were also used to estimate the tooth doses. EPR is a dose reconstruction method of measuring free radicals induced by radiation exposure to the calcified tissue (mainly in the tooth enamel or bone) to evaluate the accepted high dose. The tooth doses estimated by TLD and EPR methods were compared. Relationships between the tooth doses and effective doses by dental X-ray examinations with different types of X-ray equipment were investigated in this work.
Air radon concentration decrease in a waste water treatment plant.
Juste, B; Ortiz, J; Verdú, G; Martorell, S
2015-06-01
(222)Rn is a naturally occurring gas created from the decay of (226)Ra. The long-term health risk of breathing radon is lung cancer. One particular place where indoor radon concentrations can exceed national guidelines is in wastewater treatment plants (WWTPs) where treatment processes may contribute to ambient airborne concentrations. The aim of this paper was to study the radon concentration decrease after the application of corrective measures in a Spanish WWTP. According to first measures, air radon concentration exceeded International Commission Radiologica1 Protection (ICRP) normative (recommends intervention between 400 and 1000 Bq m(-3)). Therefore, the WWTP improved mechanical forced ventilation to lower occupational exposure. This measure allowed to increase the administrative controls, since the limitation of workers access to the plant changed from 2 h d(-1) (considering a maximum permissible dose of 20 mSv y(-1) averaged over 5 y) to 7 h d(-1). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Determination of quality factors by microdosimetry
NASA Astrophysics Data System (ADS)
Al-Affan, I. A. M.; Watt, D. E.
1987-03-01
The application of microdose parameters for the specification of a revised scale of quality factors which would be applicable at low doses and dose rates is examined in terms of an original proposal by Rossi. Two important modifications are suggested to enable an absolute scale of quality factors to be constructed. Allowance should be made to allow for the dependence of the saturation threshold of lineal energy on the type of heavy charged particle. Also, an artificial saturation threshold should be introduced for electron tracks as a mean of modifying the measurements made in the microdosimeter to the more realistic site sizes of nanometer dimensions. The proposed absolute scale of quality factors nicely encompasses the high RBEs of around 3 observed at low doses for tritium β rays and is consistent with the recent recommendation of the ICRP that the quality factor for fast neutrons be increased by a factor of two, assuming that there is no biological repair for the reference radiation.
2018-05-02
IDSA did not endorse the 2016 Surviving Sepsis Campaign Guidelines despite being represented in the working group that drafted the guidelines document. Leadership from the IDSA, the Surviving Sepsis Campaign Guidelines, and the Society of Critical Care Medicine had numerous amicable discussions primarily regarding the bolded, rated guidelines recommendations. Our societies had different perspectives, however, regarding the interpretation of the major studies that informed the guidelines' recommendations, thus leading us to different conclusions and different perspectives on the recommendations. IDSA consequently elected not to endorse the guidelines. IDSA nonetheless hopes to be able to continue collaborating with the Surviving Sepsis Campaign and the Society of Critical Care Medicine to resolve our differences and to develop further strategies together to prevent sepsis and septic shock as well as reduce death and disability from these conditions both nationally and globally.
Symon, Brian; Bammann, Michael
2012-04-01
Current World Health Organization guidelines recommend exclusive breastfeeding for the first 6 months of life. Breastfeeding conveys clear benefits to both mother and child. These benefits are likely to be amplified by prolonged feeding. This article outlines the emerging evidence that suggests possible benefits from introducing complementary solids from 4 months of age in developed countries. The human gut may have a critical early window during which it has an opportunity to develop immunological tolerance. Introducing complementary solids from 4 months of age may decrease the risk of food allergy and coeliac disease - immunological illnesses that have become a public health priority. The new draft National Health and Medical Research Council guidelines recommend introducing solids at around 6 months (22-26 weeks). However, given recent evidence, it may be appropriate to recommend the introduction of solids from 4 months of age in the Australian context.
Recommendations for the prescription of physical exercise for patients with spondyloarthritis.
Flórez García, Mariano Tomás; Carmona, Loreto; Almodóvar, Raquel; Fernández de Las Peñas, César; García Pérez, Fernando; Pérez Manzanero, M Ángeles; García García, José Manuel; Soriano Segarra, Lidón; Jiménez Díaz, José Fernando; Mendoza Laiz, Nuria; de Miguel Mendieta, Eugenio; Torre Alonso, Juan Carlos; Linares Ferrando, Luis Francisco; Collantes Estévez, Eduardo; Sanz Sanz, Jesús; Zarco Montejo, Pedro
2017-08-11
To develop expert-based recommendations on physical activity and exercise for patients with spondyloarthritis (SpA). Two discussion groups, one of physical therapists, rehabilitation physicians, and professionals of physical activity and sports, and another of rheumatologists interested in SpA, were held to discuss the results of a survey of rheumatologists on exercise and two focus groups with patients on barriers to exercise. Preliminary recommendations were drafted. These were submitted to the opinion of the experts in both groups according to a two round Delphi methodology. Twenty one recommendations covering general aspects of exercise, adaptation to patient, how to deliver messages, pain management, and type of exercise and monitoring were issued. The level of agreement varied slightly between expert groups but it was high overall. Items with poor agreement were removed from the consensus. We present recommendations on when and how to prescribe and monitor exercise in patients with SpA based on the opinion of experts in exercise and in SpA. We must now test whether these recommendations are useful for clinical practice and have an effect on patients with SpA seen by rheumatologists. Copyright © 2017. Publicado por Elsevier España, S.L.U.
Pharmacologic Therapy for Pulmonary Arterial Hypertension in Adults
Taichman, Darren B.; Chung, Lorinda; Klinger, James R.; Lewis, Sandra; Mandel, Jess; Palevsky, Harold I.; Rich, Stuart; Sood, Namita; Rosenzweig, Erika B.; Trow, Terence K.; Yung, Rex; Elliott, C. Gregory; Badesch, David B.
2014-01-01
OBJECTIVE: Choices of pharmacologic therapies for pulmonary arterial hypertension (PAH) are ideally guided by high-level evidence. The objective of this guideline is to provide clinicians advice regarding pharmacologic therapy for adult patients with PAH as informed by available evidence. METHODS: This guideline was based on systematic reviews of English language evidence published between 1990 and November 2013, identified using the MEDLINE and Cochrane Library databases. The strength of available evidence was graded using the Grades of Recommendations, Assessment, Development, and Evaluation methodology. Guideline recommendations, or consensus statements when available evidence was insufficient to support recommendations, were developed using a modified Delphi technique to achieve consensus. RESULTS: Available evidence is limited in its ability to support high-level recommendations. Therefore, we drafted consensus statements to address many clinical questions regarding pharmacotherapy for patients with PAH. A total of 79 recommendations or consensus statements were adopted and graded. CONCLUSIONS: Clinical decisions regarding pharmacotherapy for PAH should be guided by high-level recommendations when sufficient evidence is available. Absent higher level evidence, consensus statements based upon available information must be used. Further studies are needed to address the gaps in available knowledge regarding optimal pharmacotherapy for PAH. PMID:24937180
A Methodology for Selection of a Satellite Servicing Architecture. Volume 3. Appendices.
1985-12-01
draft copies of this work is greatly appreciated. Dis DII ii, I - A special measure of gratitude belongs to Major Dennis Clark for his help with...bute pair when its complementary set changed values, that pair of attributes can be considered PPI of its complemen- tary set. It is recommended that...a system. 2-2 Mission Accomplishment: The system is desired to accomplish its mission by meeting various specifica- tions. These specifications
Schneider, Lon S
2014-03-01
The February 2013 Food and Drug Administration (FDA) draft guidance for developing drugs for early-stage Alzheimer's disease (AD) creates certain challenges as they guide toward the use of one cognitive outcome to gain accelerated marketing approval for preclinical AD drugs, and a composite clinical scale - the Clinical Dementia Rating Scale in particular - for the primary outcome for prodromal AD clinical trials. In light of the developing knowledge regarding early stage diagnoses and clinical trials outcomes, we recommend that FDA describe its requirements for validating preclinical AD diagnoses for drug development purposes, maintain the principle for requiring coprimary outcomes, and encourage the advancement of outcomes for early stage AD trials. The principles for drug development for early stage AD should not differ from those for clinical AD, especially as the diagnoses of prodromal and early AD impinge on each other. The FDA should not recommend that a composite scale be used as a sole primary efficacy outcome to support a marketing claim unless it requires that the cognitive and functional components of such a scale are demonstrated to be individually meaningful. The current draft guidelines may inadvertently constrain efforts to better assess the clinical effects of new drugs and inhibit innovation in an area where evidence-based clinical research practices are still evolving. Copyright © 2014 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
Sheu, Bor-Shyang; Wu, Ming-Shiang; Chiu, Cheng-Tang; Lo, Jing-Chuan; Wu, Deng-Chyang; Liou, Jyh-Ming; Wu, Chun-Ying; Cheng, Hsiu-Chi; Lee, Yi-Chia; Hsu, Ping-I; Chang, Chun-Chao; Chang, Wei-Lun; Lin, Jaw-Town
2017-06-01
Previous international consensus statements provided general policies for the management of Helicobacter pylori infection. However, there are geographic differences in the prevalence and antimicrobial resistance of H. pylori, and in the availability of medications and endoscopy. Thus, nationwide or regional consensus statements are needed to improve control of H. pylori infection and gastric cancer. This consensus statement for management of H. pylori in Taiwan has three major sections: (1) optimal diagnosis and indications; (2) current treatment strategies; and (3) screening-to-treat and surveillance for control of gastric cancer. The literature review emphasized recent data for development of draft statements and determination of levels of evidence. Twenty-five Taiwan experts conducted a consensus conference, by a modified Delphi process, to modify the draft statements. Consensus, defined as an agreement of least 80% of the experts, and recommendation grade were determined by anonymous voting. There were 24 consensus statements. Section 1 has seven statements on recommendations for the diagnosis and indications for treatment of H. pylori infection. Section 2 has 10 statements that provide an updated treatment algorithm for first-line, second-line, and third-line regimens. Section 3 has seven statements regarding H. pylori eradication for reducing the risk of gastric cancer, with a cost-benefit analysis. After H. pylori eradication, the consensus highlights the use of endoscopic surveillance and/or chemoprevention to further reduce the burden of gastric cancer. This consensus statement has updated recommendations for improving the clinical management of H. pylori infection in areas such as Taiwan, which have high prevalence of H. pylori infection and gastric cancer. © 2017 The Authors. Helicobacter Published by John Wiley & Sons Ltd.
Parameters of care for craniosynostosis.
McCarthy, Joseph G; Warren, Stephen M; Bernstein, Joseph; Burnett, Whitney; Cunningham, Michael L; Edmond, Jane C; Figueroa, Alvaro A; Kapp-Simon, Kathleen A; Labow, Brian I; Peterson-Falzone, Sally J; Proctor, Mark R; Rubin, Marcie S; Sze, Raymond W; Yemen, Terrance A
2012-01-01
A multidisciplinary meeting was held from March 4 to 6, 2010, in Atlanta, Georgia, entitled "Craniosynostosis: Developing Parameters for Diagnosis, Treatment, and Management." The goal of this meeting was to create parameters of care for individuals with craniosynostosis. Fifty-two conference attendees represented a broad range of expertise, including anesthesiology, craniofacial surgery, dentistry, genetics, hand surgery, neurosurgery, nursing, ophthalmology, oral and maxillofacial surgery, orthodontics, otolaryngology, pediatrics, psychology, public health, radiology, and speech-language pathology. These attendees also represented 16 professional societies and peer-reviewed journals. The current state of knowledge related to each discipline was reviewed. Based on areas of expertise, four breakout groups were created to reach a consensus and draft specialty-specific parameters of care based on the literature or, in the absence of literature, broad clinical experience. In an iterative manner, the specialty-specific draft recommendations were presented to all conference attendees. Participants discussed the recommendations in multidisciplinary groups to facilitate exchange and consensus across disciplines. After the conference, a pediatric intensivist and social worker reviewed the recommendations. Consensus was reached among the 52 conference attendees and two post hoc reviewers. Longitudinal parameters of care were developed for the diagnosis, treatment, and management of craniosynostosis in each of the 18 specialty areas of care from prenatal evaluation to adulthood. To our knowledge, this is the first multidisciplinary effort to develop parameters of care for craniosynostosis. These parameters were designed to help facilitate the development of educational programs for the patient, families, and health-care professionals; stimulate the creation of a national database and registry to promote research, especially in the area of outcome studies; improve credentialing of interdisciplinary craniofacial clinical teams; and improve the availability of health insurance coverage for all individuals with craniosynostosis.
Drafting standards on cognitive accessibility: a global collaboration.
Steel, Emily J; Janeslätt, Gunnel
2017-05-01
The International Organization for Standardization (ISO) is working on accessibility of products to support people with cognitive impairment. Working Group 10, within the technical committee 173 (assistive products for persons with disability) was formed in 2014 to draft standards for assistive products that support people with cognitive impairment. This article explains the scope and purpose of the working group and the context for its formation, and describes the plans and process for drafting and publishing new international standards. The proposed suite of standards is presented, with examples from a draft standard on daily time management. It draws on international research evidence for the effectiveness of assistive products designed to support time management in people with cognitive impairment. Examples of assistive products and their key features are provided based on domains of time as defined in the International Classification of Functioning, Disability and Health for Children and Youth (ICF-CY). The proposed standards will provide design recommendations for features and functions that increase the accessibility of products used by people with cognitive impairment. They are intended to be used by designers, manufactures, educators and services providers, to facilitate their commitment to inclusion and demonstrate their willingness to work with accessibility regulation. Implications for Rehabilitation New standards based on universal design (UD) principles can guide the design of more user-friendly assistive products for people with cognitive impairment. Greater usability of assistive products, whether mainstream or specially-designed, will make it easier for practitioners to find and introduce assistive solutions to individuals with cognitive impairment. Greater usability of assistive products for daily time management can decrease the need for user training and support and enable participation.
Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette
2015-06-01
The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.
[Health Risk Assessment of Drinking Water Quality in Tianjin Based on GIS].
Fu, Gang; Zeng, Qiang; Zhao, Liang; Zhang, Yue; Feng, Bao-jia; Wang, Rui; Zhang, Lei; Wang, Yang; Hou, Chang-chun
2015-12-01
This study intends to assess the potential health hazards of drinking water quality and explore the application of geographic information system( GIS) in drinking water safety in Tianjin. Eight hundred and fifty water samples from 401 sampling points in Tianjin were measured according to the national drinking water standards. The risk assessment was conducted using the environmental health risk assessment model recommended by US EAP, and GIS was combined to explore the information visualization and risk factors simultaneously. The results showed that the health risks of carcinogens, non-carcinogens were 3.83 x 10⁻⁵, 5.62 x 10⁻⁹ and 3.83 x 10⁻⁵ for total health risk respectively. The rank of health risk was carcinogen > non-carcinogen. The rank of carcinogens health risk was urban > new area > rural area, chromium (VI) > cadmium > arsenic > trichlormethane > carbon tetrachloride. The rank of non-carcinogens health risk was rural area > new area > urban, fluoride > cyanide > lead > nitrate. The total health risk level of drinking water in Tianjin was lower than that of ICRP recommended level (5.0 x 10⁻⁵), while was between US EPA recommended level (1.0 x 10⁻⁴-1.0 x 10⁻⁶). It was at an acceptable level and would not cause obvious health hazards. The main health risks of drinking water came from carcinogens. More attentions should be paid to chromium (VI) for carcinogens and fluoride for non-carcinogens. GIS can accomplish information visualization of drinking water risk assessment and further explore of risk factors.
Sato, Tatsuhiko; Endo, Akira; Niita, Koji
2010-04-21
The fluence to organ-absorbed-dose and effective-dose conversion coefficients for heavy ions with atomic numbers up to 28 and energies from 1 MeV/nucleon to 100 GeV/nucleon were calculated using the PHITS code coupled to the ICRP/ICRU adult reference computational phantoms, following the instruction given in ICRP Publication 103 (2007 (Oxford: Pergamon)). The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. The calculation results indicate that the effective dose can generally give a conservative estimation of the effective dose equivalent for heavy-ion exposure, although it is occasionally too conservative especially for high-energy lighter-ion irradiations. It is also found from the calculation that the conversion coefficients for the Q(y)-based effective dose equivalents are generally smaller than the corresponding Q(L)-based values because of the conceptual difference between LET and y as well as the numerical incompatibility between the Q(L) and Q(y) relationships. The calculated data of these dose conversion coefficients are very useful for the dose estimation of astronauts due to cosmic-ray exposure.
Matsumoto, Masaki; Yamanaka, Tsuneyasu; Hayakawa, Nobuhiro; Iwai, Satoshi; Sugiura, Nobuyuki
2015-03-01
This paper describes the Basic Radionuclide vAlue for Internal Dosimetry (BRAID) code, which was developed to calculate the time-dependent activity distribution in each organ and tissue characterised by the biokinetic compartmental models provided by the International Commission on Radiological Protection (ICRP). Translocation from one compartment to the next is taken to be governed by first-order kinetics, which is formulated by the first-order differential equations. In the source program of this code, the conservation equations are solved for the mass balance that describes the transfer of a radionuclide between compartments. This code is applicable to the evaluation of the radioactivity of nuclides in an organ or tissue without modification of the source program. It is also possible to handle easily the cases of the revision of the biokinetic model or the application of a uniquely defined model by a user, because this code is designed so that all information on the biokinetic model structure is imported from an input file. The sample calculations are performed with the ICRP model, and the results are compared with the analytic solutions using simple models. It is suggested that this code provides sufficient result for the dose estimation and interpretation of monitoring data. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
New Radiation Dosimetry Estimates for [18F]FLT based on Voxelized Phantoms.
Mendes, B M; Ferreira, A V; Nascimento, L T C; Ferreira, S M Z M D; Silveira, M B; Silva, J B
2018-04-25
3'-Deoxy-3-[ 18 F]fluorothymidine, or [ 18 F]FLT, is a positron emission tomography (PET) tracer used in clinical studies for noninvasive assessment of proliferation activity in several types of cancer. Although the use of this PET tracer is expanding, to date, few studies concerning its dosimetry have been published. In this work, new [ 18 F]FLT dosimetry estimates are determined for human and mice using Monte Carlo simulations. Modern voxelized male and female phantoms and [ 18 F]FLT biokinetic data, both published by the ICRP, were used for simulations of human cases. For most human organs/tissues the absorbed doses were higher than those reported in ICRP Publication 128. An effective dose of 1.70E-02 mSv/MBq to the whole body was determined, which is 13.5% higher than the ICRP reference value. These new human dosimetry estimates obtained using more realistic human phantoms represent an advance in the knowledge of [ 18 F]FLT dosimetry. In addition, mice biokinetic data were obtained experimentally. These data and a previously developed voxelized mouse phantom were used for simulations of animal cases. Concerning animal dosimetry, absorbed doses for organs/tissues ranged from 4.47 ± 0.75 to 155.74 ± 59.36 mGy/MBq. The obtained set of organ/tissue radiation doses for healthy Swiss mice is a useful tool for application in animal experiment design.
Radon Dose Determination for Cave Guides in Czech Republic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thinova, Lenka; Rovenska, Katerina
2008-08-07
According to recommended approach there are six (from total of twelve) open-to-public caves in Czech Republic, reaching near to an effective lung-dose of 6mSv/year. A conservative approach for estimating the potential effective lung-dose in caves (or underground) is based on two season's measurements, using solid state alpha track detector (Kodak in plastic diffusion chamber). The obtained dataset is converted into an annual effective dose, in agreement with the ICRP65 recommendation, using the 'cave factor' 1.5. The value of 'cave factor' which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached/attached ratio (6.5 : 93.5more » for residential places, 13.6 : 86.4 for caves due to lower concentration of free aerosols) and on the equilibrium factor. Thus conversion factor is 1.5 times higher in comparison with ICRP 65. Is this correct? Because a more precisely determined dose value would have a significant impact on radon remedies, or on restricting the time workers stay underground, a series of measurement was initiated in 2003 with the aim to specify input data, computation and errors in effective dose assessment in each one of the evaluated caves separately. The enhancement of personal dosimetry for underground work places includes a study of the given questions, from the following points of view in each cave: continual radon measurement; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of free {sup 218}Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoil and in water inside/outside, a study of the radon sources in the cave; determination of the free fraction from continual unattached and attached fraction measurement (grid and filter); thoron measurement. Air flow measurements provide very interesting information about the origin of 'radon pockets' with very high radon concentration, and enable study of the location of the radon supply and its transfer among individual areas of the cave. Most of the results show the equilibrium factor around F = 0.2-0.7 and the unattached fraction around 2%-30%. One of the most important question remains: how accurately was the unattached fraction measured? Part of this project was to verify the influence of etched track detector position in the cave.« less
Li, Wei Bo; Höllriegl, Vera; Roth, Paul; Oeh, Uwe
2006-07-01
Intestinal absorption of strontium (Sr) in thirteen healthy adult German volunteers has been investigated by simultaneous oral and intravenous administration of two stable tracer isotopes, i.e. (84)Sr and (86)Sr. The measured Sr tracer concentration in plasma was analyzed using the convolution integral technique to obtain the intestinal absorption rate. The results showed that the Sr labeled in different foodstuffs was absorbed into the body fluids in a large range of difference. The maximum Sr absorption rates were observed within 60-120 min after administration. The rate of absorption is used to evaluate the intestinal absorption fraction, i.e. the f (1) value for various foodstuffs. The equivalent and effective dose coefficients for ingestion of (90)Sr were calculated using these f (1) values, and they were compared with those recommended by the International Commission on Radiological Protection (ICRP). The geometric and arithmetic means of the f (1) values are 0.38 and 0.45 associated with a geometric standard deviation and a standard deviation of 1.88 and 0.22, respectively. The 90% confidence interval of the f (1) values obtained in the present study ranges from 0.13 to 0.98. Expressed as the ratio of the 95 and 50% percentiles of the estimated probability, the uncertainty for the f (1) value corresponds to a factor of 2.58. The effective dose coefficients of (90)Sr after ingestion are 6.1 x 10(-9) Sv Bq(-1) for an f(1) value of 0.05, 1.0 x 10(-8) Sv Bq(-1) for 0.1, 1.9 x 10(-8) Sv Bq(-1) for 0.2, 2.8 x 10(-8) Sv Bq(-1) for 0.3, 3.6 x 10(-8) Sv Bq(-1) for 0.4, 5.3 x 10(-8) Sv Bq(-1) for 0.6, 7.1 x 10(-8) Sv Bq(-1) for 0.8, and 7.9 x 10(-8) Sv Bq(-1) for 0.9, respectively. Taking the effective dose coefficient of 2.8 x 10(-8) Sv Bq(-1) for an f (1) value of 0.3, which is recommended by the ICRP, as a reference, the effective dose coefficient of (90)Sr after ingestion varies by a factor of 2.8 when the f (1) value changes by a factor of 3, i.e. it decreases from 0.3 to 0.1 or increases from 0.3 to 0.9, respectively.
Froning, M; Kozielewski, T; Schläger, M; Hill, P
2004-01-01
In 1987, a worker was internally contaminated with 137Cs as a result of an accident during the handling of high temperature reactor fuel element ash. In the long-term follow-up monitoring an unusual retention behaviour was found. The observed time dependence of caesium retention does not agree with the standard models of ICRP Publication 30. The present case can be better explained by assuming an intake of a mixture of type F and type S compounds. However, experimental data can be best described by a four-exponential retention function with two long-lived components, which was used as an ad hoc model for dose calculation. The resulting dose is compared with doses calculated on the basis of ICRP Publication 66.
The evolving role of paramedics - a NICE problem to have?
Eaton, Georgette; Mahtani, Kamal; Catterall, Matt
2018-07-01
This short essay supports the growing role of paramedics in the clinical and academic workforce. We present a commentary of recent draft consultations by the National Institute for Health and Care Excellence in England that set out how the role of paramedics may be evolving to assist with the changing demands on the clinical workforce. Using these consultations as a basis, we extend their recommendations and suggest that the profession should also lead the academically driven evaluation of these new roles.
National Labor Relations Board: Action Needed to Improve Case-Processing Time at Headquarters
1991-01-01
Board more than 2 years. The Board agreed with the report regarding (1) the disruptive impact of Board-member turnover and vacancies, (2) Board...establish) and the impact of lead case delays were signifi- cant factors that warrant the extent of discussion in the report. ’’A Staff Report on the...of course, too early to evaluate the final impact of the Draft Report’s recommendations on action needed to improve case-processing time at the five
1983-12-01
Initializes the data tables shared by both the Local and Netowrk Operating Systems. 3. Invint: Written in Assembly Language. Initializes the Input/Output...connection with an appropriate type and grade of transport service and appropriate security authentication (Ref 6:38). Data Transfer within a session...V.; Kent, S. Security in oihr Level Protocolst Anorgaches. Alternatives and Recommendations, Draft Report ICST/HLNP-81-19, Wash ingt on,,D.C.: Dept
NASA Technical Reports Server (NTRS)
Davarian, Faramaz; Bishop, Dennis
1993-01-01
Propagation models that can be used for the design of earth-space land mobile-satellite telecommunications systems are presented. These models include: empirical roadside shadowing, attenuation frequency scaling, fade and non-fade duration distribution, multipath in a mountain environment, and multipath in a roadside tree environment. Propagation data from helicopter-mobile and satellite-mobile measurements in Australia and the United States were used to develop the models.
NASA Technical Reports Server (NTRS)
Davarian, F.; Bishop, D.
1993-01-01
Propogation models that can be used for the design of Earth-space land mobile-satellite telecommunications systems are presented. These models include: empirical roadside shadowing, attenuation frequency scaling, fade and non-fade duration distribution, multipath in a mountain environment, and multipath in a roadside tree environment. Propogation data from helicopter-mobile and satellite-mobile measurements in Australia and the United States were used to develop the models.
IRIS Toxicological Review of Inorganic Arsenic (Cancer) ...
EPA's Science Advisory Board (SAB) conducted a review of the scientific basis supporting the human health cancer hazard and dose-response assessment of inorganic arsenic that will appear on the Integrated Risk Information System (IRIS) database. EPA revised the assessment and is now returning the assessment to the SAB and releasing the document to the public for a focused review of EPA's responses to the SAB recommendations. This draft IRIS health assessment addresses only cancer human health effects that may result from chronic exposure to this chemical.
Creative revision - From rough draft to published paper
NASA Technical Reports Server (NTRS)
Buehler, M. F.
1976-01-01
The process of revising a technical or scientific paper can be performed more efficiently by the people involved (author, co-author, supervisor, editor) when the revision is controlled by breaking it into a series of steps. The revision process recommended here is based on the levels-of-edit concept that resulted from a study of the technical editorial function at the Jet Propulsion Laboratory of the California Institute of Technology. Types of revision discussed are Substantive, Policy, Language, Mechanical Style, Format, Integrity, and Copy Clarification.
Developing and Pretesting a Text Messaging Program for Health Behavior Change: Recommended Steps.
Abroms, Lorien C; Whittaker, Robyn; Free, Caroline; Mendel Van Alstyne, Judith; Schindler-Ruwisch, Jennifer M
2015-12-21
A growing body of evidence demonstrates that text messaging-based programs (short message service [SMS]) on mobile phones can help people modify health behaviors. Most of these programs have consisted of automated and sometimes interactive text messages that guide a person through the process of behavior change. This paper provides guidance on how to develop text messaging programs aimed at changing health behaviors. Based on their collective experience in designing, developing, and evaluating text messaging programs and a review of the literature, the authors drafted the guide. One author initially drafted the guide and the others provided input and review. Steps for developing a text messaging program include conducting formative research for insights into the target audience and health behavior, designing the text messaging program, pretesting the text messaging program concept and messages, and revising the text messaging program. The steps outlined in this guide may help in the development of SMS-based behavior change programs.
Assessment of the Draft AIAA S-119 Flight Dynamic Model Exchange Standard
NASA Technical Reports Server (NTRS)
Jackson, E. Bruce; Murri, Daniel G.; Hill, Melissa A.; Jessick, Matthew V.; Penn, John M.; Hasan, David A.; Crues, Edwin Z.; Falck, Robert D.; McCarthy, Thomas G.; Vuong, Nghia;
2011-01-01
An assessment of a draft AIAA standard for flight dynamics model exchange, ANSI/AIAA S-119-2011, was conducted on behalf of NASA by a team from the NASA Engineering and Safety Center. The assessment included adding the capability of importing standard models into real-time simulation facilities at several NASA Centers as well as into analysis simulation tools. All participants were successful at importing two example models into their respective simulation frameworks by using existing software libraries or by writing new import tools. Deficiencies in the libraries and format documentation were identified and fixed; suggestions for improvements to the standard were provided to the AIAA. An innovative tool to generate C code directly from such a model was developed. Performance of the software libraries compared favorably with compiled code. As a result of this assessment, several NASA Centers can now import standard models directly into their simulations. NASA is considering adopting the now-published S-119 standard as an internal recommended practice.
Science Goals of the U.S. Department of the Interior Southeast Climate Science Center
Dalton, Melinda S.
2011-01-01
In 2011, the U.S. Department of the Interior Southeast Climate Science Center (CSC) finalized the first draft of its goals for research needed to address the needs of natural and cultural partners for climate science in the Southeastern United States. The science themes described in this draft plan were established to address the information needs of ecoregion conservation partnerships, such as the Landscape Conservation Cooperatives (LCCs) and other regional conservation-science and resource-management partners. These themes were developed using priorities defined by partners and stakeholders in the Southeast and on a large-scale, multidisciplinary project-the Southeast Regional Assessment Project (SERAP)-developed in concert with those partners. Science products developed under these themes will provide models of potential future conditions, assessments of likely impacts, and tools that can be used to inform the conservation management decisions of LCCs and other partners. This information will be critical as managers try to anticipate and adapt to climate change. Resource managers in the Southeast are requesting this type of information, in many cases as a result of observed climate change effects. The Southeast CSC draft science plan identifies six science themes and frames the activities (tasks, with examples of recommended near-term work for each task included herein) related to each theme that are needed to achieve the objectives of the Southeast CSC.
[International trend of guidance for nanomaterial risk assessment].
Hirose, Akihiko
2013-01-01
In the past few years, several kinds of opinions or recommendations on the nanomaterial safety assessment have been published from international or national bodies. Among the reports, the first practical guidance of risk assessment from the regulatory body was published from the European Food Safety Authorities in May 2011, which included the determination of exposure scenario and toxicity testing strategy. In October 2011, European Commission (EC) adopted the definition of "nanomaterial" for regulation. And more recently, Scientific Committee on Consumer Safety of EC released guidance for assessment of nanomaterials in cosmetics in June 2012. A series of activities in EU marks an important step towards realistic safety assessment of nanomaterials. On the other hand, the US FDA announced a draft guidance for industry in June 2011, and then published draft guidance documents for both "Cosmetic Products" and "Food Ingredients and Food Contact Substances" in April 2012. These draft documents do not restrictedly define the physical properties of nanomaterials, but when manufacturing changes alter the dimensions, properties, or effects of an FDA-regulated product, the products are treated as new products. Such international movements indicate that most of nanomaterials with any new properties would be assessed or regulated as new products by most of national authorities in near future, although the approaches are still case by case basis. We will introduce such current international activities and consideration points for regulatory risk assessment.
Hemorrhagic fever viruses as biological weapons: medical and public health management.
Borio, Luciana; Inglesby, Thomas; Peters, C J; Schmaljohn, Alan L; Hughes, James M; Jahrling, Peter B; Ksiazek, Thomas; Johnson, Karl M; Meyerhoff, Andrea; O'Toole, Tara; Ascher, Michael S; Bartlett, John; Breman, Joel G; Eitzen, Edward M; Hamburg, Margaret; Hauer, Jerry; Henderson, D A; Johnson, Richard T; Kwik, Gigi; Layton, Marci; Lillibridge, Scott; Nabel, Gary J; Osterholm, Michael T; Perl, Trish M; Russell, Philip; Tonat, Kevin
2002-05-08
To develop consensus-based recommendations for measures to be taken by medical and public health professionals if hemorrhagic fever viruses (HFVs) are used as biological weapons against a civilian population. The Working Group on Civilian Biodefense included 26 representatives from academic medical centers, public health, military services, governmental agencies, and other emergency management institutions. MEDLINE was searched from January 1966 to January 2002. Retrieved references, relevant material published prior to 1966, and additional sources identified by participants were reviewed. Three formal drafts of the statement that synthesized information obtained in the evidence-gathering process were reviewed by the working group. Each draft incorporated comments and judgments of the members. All members approved the final draft. Weapons disseminating a number of HFVs could cause an outbreak of an undifferentiated febrile illness 2 to 21 days later, associated with clinical manifestations that could include rash, hemorrhagic diathesis, and shock. The mode of transmission and clinical course would vary depending on the specific pathogen. Diagnosis may be delayed given clinicians' unfamiliarity with these diseases, heterogeneous clinical presentation within an infected cohort, and lack of widely available diagnostic tests. Initiation of ribavirin therapy in the early phases of illness may be useful in treatment of some of these viruses, although extensive experience is lacking. There are no licensed vaccines to treat the diseases caused by HFVs.
Korean clinical practice guideline for benign prostatic hyperplasia
Yeo, Jeong Kyun; Choi, Hun; Bae, Jae Hyun; Kim, Jae Heon; Yang, Seong Ok; Oh, Chul Young; Cho, Young Sam; Kim, Kyoung Woo
2016-01-01
In 2014, the Korean Urological Association organized the Benign Prostatic Hyperplasia Guideline Developing Committee composed of experts in the field of benign prostatic hyperplasia (BPH) with the participation of the Korean Academy of Family Medicine and the Korean Continence Society to develop a Korean clinical practice guideline for BPH. The purpose of this clinical practice guideline is to provide current and comprehensive recommendations for the evaluation and treatment of BPH. The committee developed the guideline mainly by adapting existing guidelines and partially by using the de novo method. A comprehensive literature review was carried out primarily from 2009 to 2013 by using medical search engines including data from Korea. Based on the published evidence, recommendations were synthesized, and the level of evidence of the recommendations was determined by using methods adapted from the 2011 Oxford Centre for Evidence-Based Medicine. Meta-analysis was done for one key question and four recommendations. A draft guideline was reviewed by expert peer reviewers and discussed at an expert consensus meeting until final agreement was achieved. This evidence-based guideline for BPH provides recommendations to primary practitioners and urologists for the diagnosis and treatment of BPH in men older than 40 years. PMID:26966724
SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials
Tetzlaff, Jennifer M; Gøtzsche, Peter C; Altman, Douglas G; Mann, Howard; Berlin, Jesse A; Dickersin, Kay; Hróbjartsson, Asbjørn; Schulz, Kenneth F; Parulekar, Wendy R; Krleža-Jerić, Karmela; Laupacis, Andreas; Moher, David
2013-01-01
High quality protocols facilitate proper conduct, reporting, and external review of clinical trials. However, the completeness of trial protocols is often inadequate. To help improve the content and quality of protocols, an international group of stakeholders developed the SPIRIT 2013 Statement (Standard Protocol Items: Recommendations for Interventional Trials). The SPIRIT Statement provides guidance in the form of a checklist of recommended items to include in a clinical trial protocol. This SPIRIT 2013 Explanation and Elaboration paper provides important information to promote full understanding of the checklist recommendations. For each checklist item, we provide a rationale and detailed description; a model example from an actual protocol; and relevant references supporting its importance. We strongly recommend that this explanatory paper be used in conjunction with the SPIRIT Statement. A website of resources is also available (www.spirit-statement.org). The SPIRIT 2013 Explanation and Elaboration paper, together with the Statement, should help with the drafting of trial protocols. Complete documentation of key trial elements can facilitate transparency and protocol review for the benefit of all stakeholders. PMID:23303884
de Wit, Kerstin; Curran, Janet; Thoma, Brent; Dowling, Shawn; Lang, Eddy; Kuljic, Nebojsa; Perry, Jeffrey J; Morrison, Laurie
2018-05-01
Advances in emergency medicine research can be slow to make their way into clinical care, and implementing a new evidence-based intervention can be challenging in the emergency department. The Canadian Association of Emergency Physicians (CAEP) Knowledge Translation Symposium working group set out to produce recommendations for best practice in the implementation of a new science in Canadian emergency departments. A systematic review of implementation strategies to change health care provider behaviour in the emergency department was conducted simultaneously with a national survey of emergency physician experience. We summarized our findings into a list of draft recommendations that were presented at the national CAEP Conference 2017 and further refined based on feedback through social media strategies. We produced 10 recommendations for implementing new evidence-based interventions in the emergency department, which cover identifying a practice gap, evaluating the evidence, planning the intervention strategy, monitoring, providing feedback during implementation, and desired qualities of future implementation research. We present recommendations to guide future emergency department implementation initiatives. There is a need for robust and well-designed implementation research to guide future emergency department implementation initiatives.
SPIRIT 2013 explanation and elaboration: guidance for protocols of clinical trials.
Chan, An-Wen; Tetzlaff, Jennifer M; Gøtzsche, Peter C; Altman, Douglas G; Mann, Howard; Berlin, Jesse A; Dickersin, Kay; Hróbjartsson, Asbjørn; Schulz, Kenneth F; Parulekar, Wendy R; Krleza-Jeric, Karmela; Laupacis, Andreas; Moher, David
2013-01-08
High quality protocols facilitate proper conduct, reporting, and external review of clinical trials. However, the completeness of trial protocols is often inadequate. To help improve the content and quality of protocols, an international group of stakeholders developed the SPIRIT 2013 Statement (Standard Protocol Items: Recommendations for Interventional Trials). The SPIRIT Statement provides guidance in the form of a checklist of recommended items to include in a clinical trial protocol. This SPIRIT 2013 Explanation and Elaboration paper provides important information to promote full understanding of the checklist recommendations. For each checklist item, we provide a rationale and detailed description; a model example from an actual protocol; and relevant references supporting its importance. We strongly recommend that this explanatory paper be used in conjunction with the SPIRIT Statement. A website of resources is also available (www.spirit-statement.org). The SPIRIT 2013 Explanation and Elaboration paper, together with the Statement, should help with the drafting of trial protocols. Complete documentation of key trial elements can facilitate transparency and protocol review for the benefit of all stakeholders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-10-19
This report discusses the following topics: US Nuclear Data Network Meeting; TUNL A=3--20 Data Project Activity Report 1993; INEL Mass-chain Evaluation Project Activity Report for 1993; 1993 Isotopes; Nuclear Data Project Activity Report; The NNDC Activity Report Parts A and B; Minutes of the Formats and Procedures Subcommittee; Evaluation of High-spin Nuclear Data for ENSDF and Table of Superdeformed Nuclear Bands; Proposal for Support of a Experimental High-spin; Data File/Data-Network Coordinator; Radioactive Decay and Applications; A Plan for a Horizontal Evaluation of Decay Data; ENSDF On-line System; The MacNuclide Project Expanding the Scope of the Nuclear Structure Reference File; ENSDAT:more » Evaluated Nuclear Structure Drawings and Tables; Cross Section Evaluation Working Group (CSEWG) and CSEWG Strategy Session; A Draft Proposal for a USNDN Program Advisory Council; Recommendations of Focus Group 1; Recommendations of Focus Group 2; Recommendations of Focus Group 3; Recommendations of Focus Group 4; The Table of Isotopes; The Isotopes CD-ROM; Electronic Table of Isotopes (ETOI); and Electronic Access to Nuclear Data.« less
NASA Astrophysics Data System (ADS)
O'Reilly, Shannon E.; DeWeese, Lindsay S.; Maynard, Matthew R.; Rajon, Didier A.; Wayson, Michael B.; Marshall, Emily L.; Bolch, Wesley E.
2016-12-01
An image-based skeletal dosimetry model for internal electron sources was created for the ICRP-defined reference adult female. Many previous skeletal dosimetry models, which are still employed in commonly used internal dosimetry software, do not properly account for electron escape from trabecular spongiosa, electron cross-fire from cortical bone, and the impact of marrow cellularity on active marrow self-irradiation. Furthermore, these existing models do not employ the current ICRP definition of a 50 µm bone endosteum (or shallow marrow). Each of these limitations was addressed in the present study. Electron transport was completed to determine specific absorbed fractions to both active and shallow marrow of the skeletal regions of the University of Florida reference adult female. The skeletal macrostructure and microstructure were modeled separately. The bone macrostructure was based on the whole-body hybrid computational phantom of the UF series of reference models, while the bone microstructure was derived from microCT images of skeletal region samples taken from a 45 years-old female cadaver. The active and shallow marrow are typically adopted as surrogate tissue regions for the hematopoietic stem cells and osteoprogenitor cells, respectively. Source tissues included active marrow, inactive marrow, trabecular bone volume, trabecular bone surfaces, cortical bone volume, and cortical bone surfaces. Marrow cellularity was varied from 10 to 100 percent for active marrow self-irradiation. All other sources were run at the defined ICRP Publication 70 cellularity for each bone site. A total of 33 discrete electron energies, ranging from 1 keV to 10 MeV, were either simulated or analytically modeled. The method of combining skeletal macrostructure and microstructure absorbed fractions assessed using MCNPX electron transport was found to yield results similar to those determined with the PIRT model applied to the UF adult male skeletal dosimetry model. Calculated skeletal averaged absorbed fractions for each source-target combination were found to follow similar trends of more recent dosimetry models (image-based models) but did not follow results from skeletal models based upon assumptions of an infinite expanse of trabecular spongiosa.
López-Herce, Jesús; Almonte, Enma; Alvarado, Manuel; Bogado, Norma Beatriz; Cyunel, Mariana; Escalante, Raffo; Finardi, Christiane; Guzmán, Gustavo; Jaramillo-Bustamante, Juan C; Madrid, Claudia C; Matamoros, Martha; Moya, Luis Augusto; Obando, Grania; Reboredo, Gaspar; López, Lissette R; Scheu, Christian; Valenzuela, Alejandro; Yerovi, Rocío; Yock-Corrales, Adriana
2018-03-01
To develop a Latin American Consensus about Pediatric Cardiopulmonary Resuscitation. To clarify, reinforce, and adapt some specific recommendations for pediatric patients and to stimulate the implementation of these recommendations in clinical practice. Expert consensus recommendations with Delphi methodology. Latin American countries. Experts in pediatric cardiopulmonary resuscitation from 19 Latin American countries. Delphi methodology for expert consensus. The goal was to reach consensus with all the participating experts for every recommendation. An agreement of at least 80% of the participating experts had to exist in order to deliver a recommendation. Two Delphi voting rounds were sent out electronically. The experts were asked to score between 1 and 9 their level of agreement for each recommendation. The score was then classified into three groups: strong agreement (score 7-9), moderate agreement (score 4-6), and disagreement (score 1-3). Nineteen experts from 19 countries participated in both voting rounds and in the whole process of drafting the recommendations. Sixteen recommendations about organization of cardiopulmonary resuscitation, prevention, basic resuscitation, advanced resuscitation, and postresuscitation measures were approved. Ten of them had a consensus of 100%. Four of them were agreed by all the participants except one (94.7% consensus). One recommendation was agreed by all except two experts (89.4%), and finally, one was agreed by all except three experts (84.2%). All the recommendations reached a level of agreement. This consensus adapts 16 international recommendations to Latin America in order to improve the practice of cardiopulmonary resuscitation in children. Studies should be conducted to analyze the effectiveness of the implementation of these recommendations.
Möller, Ingrid; Loza, Estibaliz; Uson, Jacqueline; Acebes, Carlos; Andreu, Jose Luis; Batlle, Enrique; Bueno, Ángel; Collado, Paz; Fernández-Gallardo, Juan Manuel; González, Carlos; Jiménez Palop, Mercedes; Lisbona, María Pilar; Macarrón, Pilar; Maymó, Joan; Narváez, Jose Antonio; Navarro-Compán, Victoria; Sanz, Jesús; Rosario, M Piedad; Vicente, Esther; Naredo, Esperanza
To develop evidence-based recommendations on the use of ultrasound (US) and magnetic resonance imaging (MRI) in patients with rheumatoid arthritis (RA). Recommendations were generated following a nominal group technique. A panel of experts, consisting of 15 rheumatologists and 3 radiologists, was established in the first panel meeting to define the scope and purpose of the consensus document, as well as chapters, potential recommendations and systematic literature reviews (we used and updated those from previous EULAR documents). A first draft of recommendations and text was generated. Then, an electronic Delphi process (2 rounds) was carried out. Recommendations were voted from 1 (total disagreement) to 10 (total agreement). We defined agreement if at least 70% of experts voted ≥7. The level of evidence and grade or recommendation was assessed using the Oxford Centre for Evidence-based Medicine Levels of Evidence. The full text was circulated and reviewed by the panel. The consensus was coordinated by an expert methodologist. A total of 20 recommendations were proposed. They include the validity of US and MRI regarding inflammation and damage detection, diagnosis, prediction (structural damage progression, flare, treatment response, etc.), monitoring and the use of US guided injections/biopsies. These recommendations will help clinicians use US and MRI in RA patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Age-specific inhalation radiation dose commitment factors for selected radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strenge, D.L.; Peloquin, R.A.; Baker, D.A.
Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are /sup 35/S, /sup 36/Cl, /sup 45/Ca, /sup 67/Ga, /sup 75/Se, /sup 85/Sr, /sup 109/Cd, /sup 113/Sn, /sup 125/I, /sup 133/Ba, /sup 170/Tm, /sup 169/Yb, /sup 182/Ta, /sup 192/Ir, /sup 198/Au, /sup 201/Tl, /sup 204/Tl, and /sup 236/Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presentedmore » for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine.« less
Uranium levels in the diet of São Paulo City residents.
Garcia, F; Barioni, A; Arruda-Neto, J D T; Deppman, A; Milian, F; Mesa, J; Rodriguez, O
2006-07-01
Natural levels of uranium in the diet of São Paulo City residents were studied, and radionuclide concentrations were measured by the fission track method on samples of typical adult food items. This information was used to evaluate the daily intake of uranium in individuals living in São Paulo City which is, according to our findings, around 0.97 microg U/day. Using the ICRP Uranium-model, we estimated the uranium accumulation and committed doses in some tissues and organs, as function of time. We compared the output of the ICRP uranium biokinetic model, tailored for the conditions prevailing in São Paulo, with experimental data from other localities. Such comparison was possible by means of a simple method we developed, which allows normalization among experimental results from different regions where distinct values of chronic daily intake are observed.
Farkas, Árpád; Balásházy, Imre
2015-04-01
A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Behrens, R
2013-07-01
In this work, conversion coefficients from electron fluence to absorbed dose to the eye lens were calculated using Monte Carlo simulations based on a detailed stylised eye model and a very simple but whole body phantom. These data supersede and complement data published earlier based on the simulation of only a single stylised eye. The new data differ from the old ones by not more than 3, 4, 7 and 16 % for angles of radiation incidence of α=0°, 15°, 30° and 45°, respectively, due to the inclusion of the whole body phantom. The data presented in the present work also complement those of a recent report of the International Commission on Radiological Protection (ICRP) (ICRP Publication 116), where conversion coefficients from electron fluence to absorbed dose to the lens of the eye are shown for solely 0°, 180° and isotropic radiation incidence (but for a much broader range of energies). In this article, values are provided for angles of incidence of 0° up to 180° in steps of 15° and for rotational geometry; no systematic deviation was observed from the values given in ICRP Publication 116 for 0° (based on the application of a bare eye) and 180° (based on the application of a voxel whole body phantom). Data are given for monoenergetic electrons from 0.1 up to 10 MeV and for a broad parallel beam geometry in vacuum.
ICRP Publication 138: Ethical Foundations of the System of Radiological Protection.
Cho, K-W; Cantone, M-C; Kurihara-Saio, C; Le Guen, B; Martinez, N; Oughton, D; Schneider, T; Toohey, R; ZöLzer, F
2018-02-01
Despite a longstanding recognition that radiological protection is not only a matter of science, but also ethics, ICRP publications have rarely addressed the ethical foundations of the system of radiological protection explicitly. The purpose of this publication is to describe how the Commission has relied on ethical values, either intentionally or indirectly, in developing the system of radiological protection with the objective of presenting a coherent view of how ethics is part of this system. In so doing, it helps to clarify the inherent value judgements made in achieving the aim of the radiological protection system as underlined by the Commission in Publication 103. Although primarily addressed to the radiological protection community, this publication is also intended to address authorities, operators, workers, medical professionals, patients, the public, and its representatives (e.g. NGOs) acting in the interest of the protection of people and the environment. This publication provides the key steps concerning the scientific, ethical, and practical evolutions of the system of radiological protection since the first ICRP publication in 1928. It then describes the four core ethical values underpinning the present system: beneficence/ non-maleficence, prudence, justice, and dignity. It also discusses how these core ethical values relate to the principles of radiological protection, namely justification, optimisation, and limitation. The publication finally addresses key procedural values that are required for the practical implementation of the system, focusing on accountability, transparency, and inclusiveness. The Commission sees this publication as a founding document to be elaborated further in different situations and circumstances.
Implementation of the integrated approach in different types of exposure scenarios.
Copplestone, D; Hirth, G; Johansen, M; Lazo, E; Takala, J; Sakai, K; Yankovich, T
2018-01-01
The International Commission on Radiological Protection (ICRP) recognises three types of exposure situations: planned, existing, and emergency. In all three situations, the release of radionuclides into the natural environment leads to exposures of non-human biota, as well as the potential for exposures of the public. This paper describes how the key principles of the ICRP system of radiological protection apply to non-human biota and members of the public in each of these exposure situations. Current work in this area within ICRP Task Group 105 is highlighted. For example, how simplified numeric criteria may be used in planned exposure situations that are protective of both the public and non-human biota. In emergency exposure situations, the initial response will always be focused on human protection; however, understanding the potential impacts of radionuclide releases on non-human biota will likely become important in terms of communication as governments and the public seek to understand the exposures that are occurring. For existing exposure situations, there is a need to better understand the potential impacts of radionuclides on animals and plants, especially when deciding on protective actions. Understanding the comparative impacts from radiological, non-radiological, and physical aspects is often important in managing the remediation of legacy sites. Task Group 105 is making use of case studies of how exposure situations have been managed in the past to provide additional guidance and advice for the protection of non-human biota.
Cavero, Icilio; Crumb, William
2005-05-01
The International Conference on Harmonization (ICH) stems from the initiative of three major world partners (Japan, USA, European Community) who composed a mutually accepted body of regulations concerning the safety, quality and efficacy requirements that new medicines have to meet in order to receive market approval. Documents on non-clinical safety pharmacology already composed by this organisation include two guidelines: the S7A adopted in 2000 and, its companion, the S7B guideline, in a draft form since 2001. The S7A guideline deals with general principles and recommendations on safety pharmacology studies designed to protect healthy volunteers and patients from potential drug-induced adverse reactions. The S7B recommends a general non-clinical testing strategy for determining the propensity of non-cardiovascular pharmaceuticals to delay ventricular repolarisation, an effect that at times progresses into life-threatening ventricular arrhythmia. In the most recent version of this document (June 2004), the strategy proposes experimental assays and a critical examination of other pertinent information for applying an 'evidence of risk' label to a compound. Regrettably, the guideline fails to deal satisfactorily with a number of crucial issues such as scoring the evidence of risk and the clinical consequences of such scoring. However, in the latter case, the S7B relies on the new ICH guideline E14 which is currently in preparation. E14 is the clinical counterpart of the S7B guideline which states that non-clinical data are a poor predictor of drug-induced repolarisation delay in humans. The present contribution summarises and assesses salient aspects of the S7A guideline as its founding principles are also applicable to the S7B guideline. The differences in strategies proposed by the various existing drafts of the latter document are critically examined together with some unresolved, crucial problems. The need for extending the objective of the S7B document to characterise the full electrophysiological profile of new pharmaceuticals is argued as this approach would more extensively assess the non-clinical cardiac safety of a drug. Finally, in order to overcome present difficulties in arriving at the definitive version of the S7B guideline, the Expert Working Group could reflect on the introduction of the S7B guideline recommendations in the S7A document, as originally intended, or on postponing the adoption of an harmonized text until the availability of novel scientific data allows solving presently contentious aspects of this and the E14 guidelines.