Sample records for drain system design

  1. Passively operated spool valve for drain-down freeze protection of thermosyphon water heaters. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-04-30

    The work done to extend the existing drain-down valve technology to provide passive drain-down freeze protection for thermosyphon-based solar water heaters is described. The basic design of the existing valve model is that of a spool valve, employing a cylindrical spool which moves axially in a mating cartridge to open and close o-rings at the two operating extremes (drain and operate) to perform the valving function. Three passive actuators to drive the basic valving mechanism were designed, fabricated, and tested. Two piping configurations used to integrate the spool valve with the thermosyphon system are described, as are the passive actuators.more » The three actuator designs are: photovoltaic driven, refrigerant-based bellows, and heat motor cable-drive designs. Costs are compared for the alternative actuator designs, and operating characteristics were examined for the thermosyphon system, including field tests. The market for the valve for thermosyphon systems is then assessed. (LEW)« less

  2. 33 CFR 149.145 - What are the requirements for curbs, gutters, drains, and reservoirs?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION..., drains, and reservoirs? Each pumping platform complex must have enough curbs, gutters, drains, and... ocean according to the port's National Pollution Discharge Elimination System permit. ...

  3. 33 CFR 149.145 - What are the requirements for curbs, gutters, drains, and reservoirs?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION..., drains, and reservoirs? Each pumping platform complex must have enough curbs, gutters, drains, and... ocean according to the port's National Pollution Discharge Elimination System permit. ...

  4. Hydraulic characteristics of an underdrained irrigation circle, Muskegon County wastewater disposal system, Michigan

    USGS Publications Warehouse

    McDonald, M.G.

    1980-01-01

    Muskegon County, Michigan, disposes of wastewater by spray irrigating farmland on its waste-disposal site. Buried drains in the highly permeable unconfined aquifer at the site control the level of the water table. Hydraulic conductivity of the aquifer and drain-leakance, the reciprocal of resistance to flow into the drains, was determined at a representative irrigation circle while calibrating a model of the groundwater flow system. Hydraulic conductivity is 0.00055 m/sec, in the north zone of the circle, and 0.00039 m/sec in the south zone. Drain leakance -6 -6 is low in both zones: 2.9 x 10m/sec in the north and 9.5 x 10 m/sec in the south. Low drain leakance is responsible for waterlogging when irrigation rates are maintained at design levels. The capacity of the study circle to accept wastewater is 35 percent less than design capacity.

  5. Hydraulic characteristics of an underdrained irrigation circle, Muskegon County, wastewater disposal system, Michigan

    USGS Publications Warehouse

    McDonald, M.G.

    1981-01-01

    Muskegon County, Michigan, disposes of waste water by spray irrigating farmland on its waste-disposal site. Buried drains in the highly permeable unconfined aquifer at the site control the level of the water table. Hydraulic conductivity of the aquifer and drain-leakance, the reciprocal of resistance to flow into the drains, was determined at a representative irrigation circle while calibrating a model of the ground-water flow system. Hydraulic conductivity is 0.00055 meter per second in the north zone of the circle and 0.00039 meter per second in the south zone. Drain leakance is low in both zones: 2.9 x 10-6 meters per second in the north and 9.5 x 10-6 meters per second in the south. Low drain leakance is responsible for waterlogging when irrigation rates are maintained at design levels. The capacity of the study circle to accept waste water is 35 percent less than design capacity.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, M.R.

    A pneumatically deployed membrane system was used to conduct radiological surveys of the pipes and drains at a Department of Energy (DOE) Formerly Utilized Sites Remedial Action Program (FUSRAP) site in Adrian, Michigan. Remedial action consisted of the removal of residual radioactive sludge and oil. The innovative technology was used to transport a high-sensitivity probe specifically designed for this application, through designated pipes and drains. Use of this system made it possible to survey over 1,000 linear ft of underground drain line in one week, with no significant safety hazards. This was the first time this technology had been fieldmore » tested at a site, resulting in cost savings of more than $1.5 million.« less

  7. Guidelines for the design of subsurface drainage systems for highway structural sections

    DOT National Transportation Integrated Search

    1972-06-01

    Design criteria and a design method for pavement subsurface drainage systems include inflow-outflow method of analysis, open graded drainage layers, collector drains, pipe outlets and markers. Design examples are given for embankment sections, cut se...

  8. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    USGS Publications Warehouse

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the curtain-drain samples from the ETA systems showed somewhat more evidence of the presence of HSTS water than did the LL systems, most of the approaches were inconclusive by themselves. The best evidence of HSTS water, from the Cl/Br ratios, indicates that the water in 10 of the 11 curtain drains, at both HSTS types, was a mixture of dilute ground water and HSTS-derived water; the 11th drain also show some effects of the HSTS, although road salt-affected water may be present. Therefore, it appears that there is no difference between the ETA and LL systems with respect to the water quality in curtain drains.

  9. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  10. Challenging Pneumatic Requirements for Acoustic Testing of the Cryogenic Second Stage for the New Delta 3 Rocket

    NASA Technical Reports Server (NTRS)

    Webb, Andrew T.

    1998-01-01

    The paper describes the unique pneumatic test requirements for the acoustic and shock separation testing of the Second Stage for the new Delta III Rocket at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 45,000 cu ft (25-feet wide by 30-feet deep by 50-foot high) Acoustic Facility. The acoustic testing required that the liquid oxygen (LOX) and liquid hydrogen (LH2) tanks be filled with enough liquid nitrogen (LN2) to simulate launch fuel masses during testing. The challenge for this test dealt with designing, procuring, and fabricating the pneumatic supply systems for quick assembly while maintaining the purity requirements and minimizing costs. The pneumatic systems were designed to fill and drain the both LOX and LH2 tanks as well as to operate the fill/drain and vent valves for each of the tanks. The test criteria for the pneumatic sub-systems consisted of function, cleanliness, availability, and cost. The first criteria, function, required the tanks to be filled and drained in an efficient manner while preventing them from seeing pressures greater than 9 psig which would add a pressure cycle to the tank. An LN2 tanker, borrowed from another NASA facility, served as the pre-cool and drain tanker. Pre-cooling the tanks allowed for more efficient and cost effective transfer from the LN2 delivery tankers. Helium gas, supplied from a high purity tube trailer, was used to pressurize the vapor space above the LN2 pushing it into the drain tanker. The tube trailer also supplied high pressure helium to the vehicle for valve control and component purges. Cleanliness was maintained by proper component selection, end-use particle filtration, and any on-site cleaning determined necessary by testing. In order to meet the availability/cost juggling act, products designed for LOX delivery systems were procured to ensure system compatibility while off the shelf valves and tubing designed for the semiconductor industry were procured for the gas systems.

  11. Solar space- and water-heating system at Stanford University. Central Food Services Building

    NASA Astrophysics Data System (ADS)

    1980-05-01

    The closed-loop drain-back system is described as offering dependability of gravity drain-back freeze protection, low maintenance, minimal costs, and simplicity. The system features an 840 square-foot collector and storage capacity of 1550 gallons. The acceptance testing and the predicted system performance data are briefly described. Solar performance calculations were performed using a computer design program (FCHART). Bidding, costs, and economics of the system are reviewed. Problems are discussed and solutions and recommendations given. An operation and maintenance manual is given.

  12. A novel thin-film transistor with step gate-overlapped lightly doped drain and raised source/drain design

    NASA Astrophysics Data System (ADS)

    Chien, Feng-Tso; Chen, Jian-Liang; Chen, Chien-Ming; Chen, Chii-Wen; Cheng, Ching-Hwa; Chiu, Hsien-Chin

    2017-11-01

    In this paper, a novel step gate-overlapped lightly doped drain (GOLDD) with raised source/drain (RSD) structure (SGORSD) is proposed for TFT electronic device application. The new SGORSD structure could obtain a low electric field at channel near the drain side owing to a step GOLDD design. Compared to the conventional device, the SGORSD TFT exhibits a better kink effect and higher breakdown performance due to the reduced drain electric field (D-EF). In addition, the leakage current also can be suppressed. Moreover, the device stability, such as the threshold voltage shift and drain current degradation under a high gate bias, is improved by the design of SGORSD structure. Therefore, this novel step GOLDD structure can be a promising design to be used in active-matrix flat panel electronics.

  13. Differential Draining of Parallel-Fed Propellant Tanks in Morpheus and Apollo Flight

    NASA Technical Reports Server (NTRS)

    Hurlbert, Eric; Guardado, Hector; Hernandez, Humberto; Desai, Pooja

    2015-01-01

    Parallel-fed propellant tanks are an advantageous configuration for many spacecraft. Parallel-fed tanks allow the center of gravity (cg) to be maintained over the engine(s), as opposed to serial-fed propellant tanks which result in a cg shift as propellants are drained from tank one tank first opposite another. Parallel-fed tanks also allow for tank isolation if that is needed. Parallel tanks and feed systems have been used in several past vehicles including the Apollo Lunar Module. The design of the feedsystem connecting the parallel tank is critical to maintain balance in the propellant tanks. The design must account for and minimize the effect of manufacturing variations that could cause delta-p or mass flowrate differences, which would lead to propellant imbalance. Other sources of differential draining will be discussed. Fortunately, physics provides some self-correcting behaviors that tend to equalize any initial imbalance. The question concerning whether or not active control of propellant in each tank is required or can be avoided or not is also important to answer. In order to provide data on parallel-fed tanks and differential draining in flight for cryogenic propellants (as well as any other fluid), a vertical test bed (flying lander) for terrestrial use was employed. The Morpheus vertical test bed is a parallel-fed propellant tank system that uses passive design to keep the propellant tanks balanced. The system is operated in blow down. The Morpheus vehicle was instrumented with a capacitance level sensor in each propellant tank in order to measure the draining of propellants in over 34 tethered and 12 free flights. Morpheus did experience an approximately 20 lb/m imbalance in one pair of tanks. The cause of this imbalance will be discussed. This paper discusses the analysis, design, flight simulation vehicle dynamic modeling, and flight test of the Morpheus parallel-fed propellant. The Apollo LEM data is also examined in this summary report of the flight data.

  14. 40 CFR 63.681 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... features permanently integrated into the design of the unit. Emission point means an individual tank... system is not a drain and collection system that is designed and operated for the sole purpose of..., or transfer system used to manage off-site material. Off-site material service means any time when a...

  15. 40 CFR 63.681 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... features permanently integrated into the design of the unit. Emission point means an individual tank... system is not a drain and collection system that is designed and operated for the sole purpose of..., or transfer system used to manage off-site material. Off-site material service means any time when a...

  16. Design of maintainable drains for earth retaining structures : final report and design guide.

    DOT National Transportation Integrated Search

    2017-04-01

    Poor drainage is by far the most common cause of poor performance for earth retention systems. Poor performance includes burdensome serviceability problems that can progress to outright failure of the earth retention system if not addressed. : A comm...

  17. Remaining Sites Verification Package for the 331 Life Sciences Laboratory Drain Field Septic System, Waste Site Reclassification Form 2008-020

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. M. Capron

    2008-10-16

    The 331 Life Sciences Laboratory Drain Field (LSLDF) septic system waste site consists of a diversion chamber, two septic tanks, a distribution box, and a drain field. This septic system was designed to receive sanitary waste water, from animal studies conducted in the 331-A and 331-B Buildings, for discharge into the soil column. However, field observations and testing suggest the 331 LSLDF septic system did not receive any discharges. In accordance with this evaluation, the confirmatory sampling results support a reclassification of the 331 LSLDF waste site to No Action. This site does not have a deep zone or othermore » condition that would warrant an institutional control in accordance with the 300-FF-2 ROD under the industrial land use scenario.« less

  18. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 23.1021 Section 23.1021... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Oil System § 23.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  19. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 29.1021 Section 29.1021... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  20. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 27.1021 Section 27.1021... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Oil System § 27.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  1. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 25.1021 Section 25.1021... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  2. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 25.1021 Section 25.1021... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  3. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 23.1021 Section 23.1021... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Oil System § 23.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  4. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 29.1021 Section 29.1021... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  5. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 27.1021 Section 27.1021... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Oil System § 27.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  6. Charge-Dissipative Electrical Cables

    NASA Technical Reports Server (NTRS)

    Kolasinski, John R.; Wollack, Edward J.

    2004-01-01

    Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

  7. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 23.1021 Section 23.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  8. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 23.1021 Section 23.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  9. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  10. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  11. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  12. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  13. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  14. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  15. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  16. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  17. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  18. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  19. SIMS prototype system 3 test results: Engineering analysis

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  20. One vs two primary LOX feedline configuration study for the National Launch System

    NASA Technical Reports Server (NTRS)

    Dill, K.; Davis, D.; Bates, R.; Tarwater, R.

    1992-01-01

    Six single LOX feedline designs were evaluated for use on the National Launch Vehicle. A single feedline design, designated the 'Spider', was chosen and compared to the baseline system. The baseline configuration employs two 20-inch I.D. lines, each supplying LOX to three 650,000 lbf thrust Space Transportation Main Engines. Five single feedline diameters were examined for the spider configuration; 22, 24, 26, 28, and 30-inch I.D. System dry weights and LOX residuals were estimated. These parameters, along with calculated staged mass for the different single line and baseline configurations, were used to calculate the payload mass to orbit. For the cases where LOX is drained to minimum NPSP conditions, none of the single lines performed as well as the dual line system, although the 22-inch diameter single line compared well. However, for the cases where LOX is drained to operating levels (LOX level at the booster and spider manifolds for the dual and single line configurations, respectively), the 22 - 26-inch I.D. single line systems show a greater payload capability.

  1. Evaluation of wick drain performance in Virginia soils.

    DOT National Transportation Integrated Search

    2003-01-01

    Prefabricated vertical drains (PVD), also known as wick drains, are commonly used to accelerate the consolidation of fine-grained soils in order to reduce future settlements and increase shear strength. Various drain designs are currently on the mark...

  2. Methods for Decontamination of a Bipropellant Propulsion System

    NASA Technical Reports Server (NTRS)

    McClure, Mark B.; Greene, Benjamin

    2012-01-01

    Most propulsion systems are designed to be filled and flown, draining can be done but decontamination may be difficult. Transport of these systems may be difficult as well because flight weight vessels are not designed around DOT or UN shipping requirements. Repairs, failure analysis work or post firing inspections may be difficult or impossible to perform due to the hazards of residual propellants being present.

  3. Stability performance and interface shear strength of geocomposite drain/soil systems

    NASA Astrophysics Data System (ADS)

    Othman, Maidiana; Frost, Matthew; Dixon, Neil

    2018-02-01

    Landfill covers are designed as impermeable caps on top of waste containment facilities after the completion of landfill operations. Geocomposite drain (GD) materials consist of a geonet or geospacer (as a drainage core) sandwiched between non-woven geotextiles that act as separators and filters. GD provides a drainage function as part of the cover system. The stability performance of landfill cover system is largely controlled by the interface shear strength mobilized between the elements of the cover. If a GD is used, the interface shear strength properties between the upper surface of the GD and the overlying soil may govern stability of the system. It is not uncommon for fine grained materials to be used as cover soils. In these cases, understanding soil softening issues at the soil interface with the non-woven geotextile is important. Such softening can be caused by capillary break behaviour and build-up of water pressures from the toe of the drain upwards into the cover soil. The interaction processes to allow water flow into a GD core through the soil-geotextile interface is very complex. This paper reports the main behaviour of in-situ interface shear strength of soil-GD using field measurements on the trial landfill cover at Bletchley, UK. The soil softening at the interface due to soaked behaviour show a reduction in interface shear strength and this aspect should be emphasized in design specifications and construction control. The results also help to increase confidence in the understanding of the implications for design of cover systems.

  4. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  5. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  6. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  7. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  8. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  9. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  10. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  11. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  12. 40 CFR 63.681 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...

  13. 40 CFR 63.681 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...

  14. 40 CFR 63.681 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...

  15. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...

  16. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...

  17. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  18. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  19. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  20. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  1. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  2. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.

    2014-01-20

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

  3. 77 FR 70382 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... the fuel tank draining system. This proposed AD is prompted by a closed fuel tank drain that, in the... fuel tank compartments' draining system. FAA's Determination These helicopters have been approved by... buoyancy fixed parts, the ASBs describe procedures to modify the fuel tank draining system by removing...

  4. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 29.1021 Section 29.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  5. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 25.1021 Section 25.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  6. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 29.1021 Section 29.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  7. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 25.1021 Section 25.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  8. Quantification of non-stormwater flow entries into storm drains using a water balance approach.

    PubMed

    Xu, Zuxin; Yin, Hailong; Li, Huaizheng

    2014-07-15

    To make decisions about correcting illicit or inappropriate connections to storm drains, quantification of non-stormwater entries into storm drains was performed using a water flow balance approach, based on data analysis from 2008 to 2011 in a separate storm drainage system in a Shanghai downtown area of 374 ha. The study revealed severe sewage connections to storm drains; meanwhile, misconnections between surface water and storm drains were found to drive frequent non-stormwater pumping discharges at the outfall, producing a much larger volume of outfall flows in a short period. This paper presented a methodology to estimate quantities of inappropriate sewage flow, groundwater infiltration and river water backflow into the storm drains. It was concluded that inappropriate sewage discharge and groundwater seepage into storm drains were approximately 17,860 m(3)/d (i.e., up to 51% of the total sewage flow in the catchment) and 3,624 m(3)/d, respectively, and surface water backflow was up to an average 28,593 m(3)/d. On the basis of this work, end-of-storm pipe interceptor sewers of 0.25 m(3)/s (i.e., 21,600 m(3)/d) would be effective to tackle the problem of sewage connections and groundwater seepage to storm drains. Under this circumstance, the follow-up non-stormwater outfall pumping events indicate misconnections between surface water and storm drains, featuring pumping discharge equivalent to surface water backflow; hence the misconnections should be repaired. The information provided here is helpful in estimating the magnitude of non-stormwater flow entries into storm drains and designing the necessary pollution control activities, as well as combating city floods in storm events. Copyright © 2014. Published by Elsevier B.V.

  9. Land-Based Dlischarge Environmental Assessment at Beale Air Force Base, California

    DTIC Science & Technology

    2009-09-01

    Attainment Designations ................. 3-3 3-3 Federally Listed Species Evaluated...drain pit includes special design features to ensure that drained effluent does not enter Hutchinson Creek. The drain pit would consist of a pipe with...The cattle fence would consist of metal T- posts , five-strand cattle wire, and a standard cattle gate with wooden posts . The wooden posts would be

  10. 14 CFR 27.859 - Heating systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Except for heaters which incorporate designs to prevent hazards in the event of fuel leakage in the... locations ensuring prompt detection of fire in the heater region. (2) Fire extinguisher systems that provide... shrouds so that no leakage from those components can enter the ventilating airstream. (k) Drains. There...

  11. Phosphorus losses from drainage systems: breaking the surface tile riser connection

    USDA-ARS?s Scientific Manuscript database

    In freshwater ecosystems, phosphorus is generally the nutrient most limiting algal growth. Agricultural drainage systems in the upper Midwestern US are generally designed to drain water as quickly as possible, in order to ensure trafficability and minimize crop damage due to flooding. An unintended ...

  12. Solar domestic water heating performance test program - Interim report

    NASA Astrophysics Data System (ADS)

    Auris, R. H.

    Performance results from utility-installed or monitored flat plate collector systems on 13 residences are reported. The systems comprised either drain-down, i.e., emptying the water-working fluid into a reservoir in response to thermistor sensing of sufficiently low temperatures, or water/glycol mixture as freeze protection measures. Installation errors committeed by commercial solar contractors employed by the utility customers are outlined, indicating the uncertainty involved in obtaining a quality installation. Most system failures occurred with the drain-down systems, which also featured the highest system efficiencies. Redundancy in the control systems is suggested to offer significant improvements in system efficiency. The systems provided an average of 40% of the annual hot water needs, and the development of low cost materials, better system designs, low cost financing, and increased tax credits are concluded to be methods of making the systems cost effective.

  13. A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions

    NASA Technical Reports Server (NTRS)

    Thomas, Evan A.; Graf, John C.; Weislogel, Mark M.

    2010-01-01

    The invention, a static phase separator (SPS), uses airflow and capillary wetting characteristics to passively separate a two-phase (liquid and air) flow. The device accommodates highly variable liquid wetting characteristics. The resultant design allows for a range of wetting properties from about 0 to over 90 advancing contact angle, with frequent complete separation of liquid from gas observed when using appropriately scaled test conditions. Additionally, the design accommodates a range of air-to-liquid flow-rate ratios from only liquid flow to over 200:1 air-to-liquid flow rate. The SPS uses a helix input section with an ice-cream-cone-shaped constant area cross section (see figure). The wedge portion of the cross section is on the outer edge of the helix, and collects the liquid via centripetal acceleration. The helix then passes into an increasing cross-sectional area vane region. The liquid in the helix wedge is directed into the top of capillary wedges in the liquid containment section. The transition from diffuser to containment section includes a 90 change in capillary pumping direction, while maintaining inertial direction. This serves to impinge the liquid into the two off-center symmetrical vanes by the airflow. Rather than the airflow serving to shear liquid away from the capillary vanes, the design allows for further penetration of the liquid into the vanes by the air shear. This is also assisted by locating the air exit ports downstream of the liquid drain port. Additionally, any droplets not contained in the capillary vanes are re-entrained downstream by a third opposing capillary vane, which directs liquid back toward the liquid drain port. Finally, the dual air exit ports serve to slow the airflow down, and to reduce the likelihood of shear. The ports are stove-piped into the cavity to form an unfriendly capillary surface for a wetting fluid to carryover. The liquid drain port is located at the start of the containment region, allowing for draining the bulk fluid in a continuous circuit. The functional operation of the SPS involves introducing liquid flow (from a human body, a syringe, or other source) to the two-phase inlet while an air fan pulls on the air exit lines. The fan is operated until the liquid is fully introduced. The system is drained by negative pressure on the liquid drain lines when the SPS containment system is full.

  14. Liquid radwaste in-leakage reduction at TVA's Browns Ferry nuclear plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, A.C.; Roccasano, J.J.

    1987-01-01

    Early in 1985, Tennessee Valley Authority's (TVA's) Browns Ferry Nuclear Plant (BFNP) decided to initiate a liquid radwaste in-leakage reduction project as part of their chemistry improvement program. The purpose of this project was to reduce the overall volume of water processed by the radwaste system at BFNP by restricting uncontrolled in-leakage through the floor drain system. Impell Corporation was contracted to perform the project, which consisted of several tasks, each design to provide data for the reduction of in-leakage or to reduce the in-leakage directly. The program was begun in March 1985. Buy July of that same year, liquidmore » input to radwaste through the floor drain system had been reduced by --30%.« less

  15. Cryogenic fluid management for low-g transfer

    NASA Technical Reports Server (NTRS)

    Frank, D. J.; Jaekle, D. E., Jr.

    1986-01-01

    An account is given of design and operations criteria pertaining to low-g environment systems for the collection and delivery of liquid cryogens to a supply tank drain inlet in orbit. Analyses must assess the draining efficiencies of such devices, because the minimization of supply tank residual contents is of the essence. Settling accelerations, passive expulsion, and positive expulsion methods of fluid control have all been successfully demonstrated in orbit. Attention is given to the unique advantages and disadvantages of each method in view of different sets of requirements.

  16. 78 FR 76995 - Endangered and Threatened Wildlife and Plants; Threatened Status for Eriogonum codium (Umtanum...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... bladderpod. The Bureau of Reclamation has installed a system of surface and buried drains designed to... characterize genetic diversity and compare tuplashensis and douglasii under the study design. We find the peer... irrigated private lands or manmade structures (such as buildings, pavement, or other structures) and the...

  17. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  18. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  19. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  20. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  1. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  2. Hydrodynamics of octagonal culture tanks with Cornell-type dual-drain system

    USDA-ARS?s Scientific Manuscript database

    Large culture tanks of several hundred or thousand m3 size are generally encouraged for economic advantages in Recirculation Aquaculture Systems (RAS). Out of numerous possibilities in designing the inlet and outlet configurations in octagonal culture tanks, the inlet pipes near the corner walls and...

  3. Containment vessel drain system

    DOEpatents

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  4. High efficiency FET microwave detector design

    NASA Astrophysics Data System (ADS)

    Luglio, Juan; Ishii, Thomas Koryu

    1990-12-01

    The work is based on an assumption that very little microwave power would be consumed at a negatively biased gate of a microwave FET, yet significant detected signals would be obtained at the drain if the bias is given. By analyzing a Taylor-series expansion of the drain-current equation in the vicinity of a fixed gate-bias voltage, the bias voltage is found to maximize the second derivative of the drain current, the gate-bias voltage characteristic curve for the maximum detected drain current under a given fixed drain-bias voltage. Based on these findings, a high-efficiency microwave detector is designed, fabricated, and tested at 8.6 GHz, and it is shown that the audio power over absorbed microwave power ratio of the detector is 135 percent due to the positive gain.

  5. Experimental utilization of tire shreds to enhance highway drainage.

    DOT National Transportation Integrated Search

    2001-03-01

    This project investigates the practical benefits of using shredded tires as a free draining material : in a subsurface French drain to enhance drainage along a section of highway. French drains are : below-grade structures designed to re-direct groun...

  6. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  7. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  8. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  9. Safety drain system for fluid reservoir

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2012-01-01

    A safety drain system includes a plurality of drain sections, each of which defines distinct fluid flow paths. At least a portion of the fluid flow paths commence at a side of the drain section that is in fluid communication with a reservoir's fluid. Each fluid flow path at the side communicating with the reservoir's fluid defines an opening having a smallest dimension not to exceed approximately one centimeter. The drain sections are distributed over at least one surface of the reservoir. A manifold is coupled to the drain sections.

  10. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...

  11. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...

  12. Translating evidence-based protocol of wound drain management for total joint arthroplasty into practice: A quasi-experimental study.

    PubMed

    Tsang, Lap Fung; Cheng, Hang Cheong; Ho, Hon Shuen; Hsu, Yung Chak; Chow, Chiu Man; Law, Heung Wah; Fong, Lup Chau; Leung, Lok Ming; Kong, Ivy Ching Yan; Chan, Chi Wai; Sham, Alice So Yuen

    2016-05-01

    Although various drains have long been used in total joint replacement, evidence suggests inconsistent practice exists in the use of drainage systems including intermittently applying suction or free of drainage suction, and variations in the optimal timing for wound drain removal. A comprehensive systematic review of available evidence up to 2013 was conducted in a previous study and a protocol was adapted for clinical application according to the summary of the retrieved information (Tsang, 2015). To determine if the protocol could reduce blood loss and blood transfusion after operation and to develop a record form so as to enhance communication of drainage record amongst surgeons and nurses. A quasi-experimental time-series design was undertaken. In the conventional group, surgeons ordered free drainage if the drain output was more than 300 ml. The time of removal of the drain was based on their professional judgement. In the protocol group the method of drainage was dependant of the drainage output as was the timing of the removal of the drain. A standardized record form was developed to guide operating room and orthopaedic ward nurses to manage the drainage system. The drain was removed significantly earlier in the protocol group. Blood loss rate at the first hour of post-operation was extremely low in the protocol group due to clamping effect. Blood loss in volume during the first three hours in the protocol group was significantly lower than that in the conventional group. Only in 11.1% and 4% of cases was it necessary to clamp at the three and four hour post-operative hours. No clamping was required at the two and eight hour postoperative period. There was no significant difference in blood loss during the removal of the drain and during blood transfusion, which was required for patients upon removal of the drain in the two groups. This is the first clinical study to develop an evidence-based protocol to manage wound drain effectively in Hong Kong. Total blood loss and blood transfusions were not significantly different between the conventional and protocol groups. A standard documentation document is beneficial to enhance communication between doctors and nurses as well as to monitor and observe drainage effectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Media filter drain : modified design evaluation and existing design longevity evaluation.

    DOT National Transportation Integrated Search

    2014-02-01

    The media filter drain (MFD), a stormwater water quality treatment best management practice, consists of media made up of : aggregate, perlite, gypsum and dolomite in a trench located along roadway shoulders with gravel and vegetative pre-filtering :...

  14. Rupture disc

    DOEpatents

    Newton, Robert G.

    1977-01-01

    The intermediate heat transport system for a sodium-cooled fast breeder reactor includes a device for rapidly draining the sodium therefrom should a sodium-water reaction occur within the system. This device includes a rupturable member in a drain line in the system and means for cutting a large opening therein and for positively removing the sheared-out portion from the opening cut in the rupturable member. According to the preferred embodiment of the invention the rupturable member includes a solid head seated in the end of the drain line having a rim extending peripherally therearound, the rim being clamped against the end of the drain line by a clamp ring having an interior shearing edge, the bottom of the rupturable member being convex and extending into the drain line. Means are provided to draw the rupturable member away from the drain line against the shearing edge to clear the drain line for outflow of sodium therethrough.

  15. Pervious concrete physical characteristics and effectiveness in stormwater pollution reduction : tech transfer summaries.

    DOT National Transportation Integrated Search

    2016-04-01

    Pervious concrete is an environmentally friendly and sustainable : material that allows rainfall to be drained and to percolate through : the concrete to the subbase/subgrade. Depending on the design of the : pervious concrete system, the pavement an...

  16. VARIATIONS OF MICROORGANISM CONCENTRATIONS IN URBAN STORMWATER RUNOFF WITH LAND USE AND SEASONS

    EPA Science Inventory

    Stormwater runoff samples were collected from outfalls draining small municipal separate storm sewer systems. The samples were collected from three different land use areas based on local designation (high-density residential, low-density residential, and landscaped commercial)....

  17. System of GIS-Based Hydrologic and Hydraulic Applications for Highway Engineering: Summary Report

    DOT National Transportation Integrated Search

    1999-10-01

    A significant part of the cost of most highway projects is attributable to drainage facilities, such as bridges, highway culverts, storm drains, and water quality and quantity control structures. Design of these facilities involves a hydrologic analy...

  18. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 27.1021 Section 27.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  19. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 27.1021 Section 27.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duignan, M. R.; Herman, D. T.; Restivo, M. L.

    Experiments at several different scales were performed to understand the removal of spherical resorcinol formaldehyde (sRF) ion exchange resin using a gravity drain system with a valve located above the resin screen in the ion exchange column (IXC). This is being considered as part of the design for the Low Activity Waste Pretreatment System (LAWPS) to be constructed at the DOE Hanford Site.

  1. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...

  2. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...

  3. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...

  4. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...

  5. 75 FR 29520 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... section 1404(b) of the Act (``Drain Cover Standard''). In addition to the anti-entrapment devices or... system; gravity drainage system; automatic pump shut-off system or drain disablement. The Pool and Spa... the drain covers, anti-entrapment device/systems, sump or equalizer lines at the site; and report on...

  6. Discussion-preliminary review of the safety aspects of the crossunder line, Project CG-884. Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, S.S.

    1960-12-19

    In order to reduce both charge-discharge shutdown time and the number of manhours of radiation exposure, Project CGI-884 is being completed at the B, D, DR, F and R Reactors. This consists essentially of installing a large drain line at the bottom of one rear reactor riser. This drain line passes to a control valve and then to the effluent line beyond the downcomer. This system by-passes the crossover downcomer part of the effluent system and eliminates the need for intermittent rear crossheader valving during reactor charge-discharge procedures. Two aspects of this system have been considered, its basic design requirements,more » and operating restrictions to ensure adequate process tube cooling. Because of the complexity of the reactor flow system approximate solutions were used to compare different methods or degrees of operation and establish limits. Despite these approximations, there was sufficient difference in the case results to justify the specific conclusions presented in this report. This report should serve the dual purpose of providing design requirements for the crossunder and also providing the technical criteria necessary for the operating standards for the use of this new system.« less

  7. Reduce oil and grease content in wastewater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capps, R.W.; Matelli, G.N.; Bradford, M.L.

    Poor water quality is often blamed on biological oxidation unit malfunction. However, poorly treated water entering the bio-unit is more often the problem. At the microscopic level, oil/water-separation dynamics are influenced by pH, fluid velocity, temperature, and unit volumes. Oily water's physical and chemical properties affect pretreatment systems such as API separators, corrugated plate interception (CPI) separators, air flotation and equalization systems. A better understanding of pretreatment systems' limits and efficiencies can improve wastewater quality before it upsets the biological oxidation (BIOX). Oil contamination in refinery wastewater originates from desalting, steam stripping, product treating, tank drains, sample drains and equipmentmore » washdown. The largest volumetric contributors are cooling tower blowdowns and contaminated stormwater. The paper describes the BIOX process; oil/water separation; oil/water emulsions and colloidal solutions; air flotation; surfactants; DAF (dissolved air flotation) process; IAF (induced air flotation) process; equalization; load factors; salts; and system design.« less

  8. Finding New Water: Development of On-Site Non-Potable Water Reuse Systems

    EPA Science Inventory

    By designing our buildings to collect and treat water generated on-site, can be and reused for flushing our toilets and irrigating our landscaping. Several water sources are generated with-in a building including: rainwater, stormwater, graywater, blackwater and foundation drain...

  9. Development of Thermal Bridging Factors for Use in Energy Models

    DTIC Science & Technology

    2015-06-20

    assemblies. 5.2.2 Drainage : Drained systems Drained (Figure 5-6) and screened enclosures assume some rainwater will penetrate the outer surface...38 5.2.2 Drainage : Drained systems ...layer (e.g., drainage plane and gap or waterproofing) 2. Airflow control layer (e.g., an air barrier system ) 3. Thermal control layer (e.g., insulation

  10. Pink-Beam, Highly-Accurate Compact Water Cooled Slits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard

    2007-01-19

    Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Elementmore » Analysis of the system are presented.« less

  11. Contoured tank outlets for draining of cylindrical tanks in low-gravity environment. [Lewis Research Center Zero Gravity Facility

    NASA Technical Reports Server (NTRS)

    Symons, E. P.

    1979-01-01

    An analysis is presented for defining the outlet contour of a hemispherical-bottomed cylindrical tank that will prevent vapor ingestion when the tank is drained. The analysis was used to design two small-scale tanks that were fabricated and then tested in a low gravity environment. The draining performance of the tanks was compared with that for a tank with a conventional outlet having a constant circular cross-sectional area, under identical conditions. Even when drained at off-design conditions, the contoured tank had less liquid residuals at vapor ingestion than the conventional outlet tank. Effects of outflow rate, gravitational environment, and fluid properties on the outlet contour are discussed. Two potential applications of outlet contouring are also presented and discussed.

  12. Discharge characteristics of four highway drainage systems in Ohio

    USGS Publications Warehouse

    Straub, D.E.

    1995-01-01

    Excessive water in the subbase of high-way combined with large traffic volumes and heavy loads is a major cause of road deterioration. Prompt removal of any excess water in a subbase will decrease the road deterioration and extend the effective life of a highway. This study presents discharge characteristics of four highway subbase drainage systems. These systems consisted of shallow, longitudal trenches with geocomposite drain materials (edge drains made from a polyethylene core surrounded by a geotextile filter fabric) that underline the joint between the shoulder and the traffic lane of State Route 16, approximately 1.0 mile southeast of Granville, Ohio. For selected rainfall-runoff events the maximum discharge, discharge characteristics from April 1991 through November 1993 were computed for three geocomposite products- a post type, an oblong-pipe type, and a cusp type-and a conventional perforated pipe edge drain. In general, the discharge characteristics of the conventional edge drain and that of the oblong-pipe edge drain were similar for most of the rainfall-runoff event characteristics. Both produced most of the highest maximum discharges and largest discharge volumes among the four longitudal edge drains. The post edge drain produced smaller maximum discharge and volumes than the conventional and oblong-pipe edge drains, but it had the shortest lag times for most of the event characteristics. The cusp edge drain produced small maximum discharges and small volumes similar to those from the post edge drain, but it had the longest lag times of all the edge drains for most of the event characteristics. The cusp edge drain may have also had some problems during installation which could have affected the discharge characteristics.

  13. Traditional Foley drainage systems--do they drain the bladder?

    PubMed

    Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L

    2007-01-01

    Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

  14. Propellant Feed Subsystem for the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    McDonald, J. P.; Minor, R. B.; Knight, K. C.; Champion, R. H., Jr.; Russell, F. J., Jr.

    1998-01-01

    The Orbital Sciences Corporation X-34 vehicle demonstrates technologies and operations key to future reusable launch vehicles. The general flight performance goal of this unmanned rocket plane is Mach 8 flight at an altitude of 250,000 feet. The Main Propulsion System supplies liquid propellants to the main engine, which provides the primary thrust for attaining mission goals. Major NMS design and operational goals are aircraft-like ground operations, quick turnaround between missions, and low initial/operational costs. This paper reviews major design and analysis aspects of the X-34 propellant feed subsystem of the X-34 Main Propulsion System. Topics include system requirements, system design, the integration of flight and feed system performance, propellant acquisition at engine start, and propellant tank terminal drain.

  15. Abdominal drainage following cholecystectomy: high, low, or no suction?

    PubMed Central

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773

  16. 10 CFR 36.33 - Irradiator pools.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... purification system designed to be capable of maintaining the water during normal operation at a conductivity..., irradiator pools must either: (1) Have a water-tight stainless steel liner or a liner metallurgically... water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter...

  17. 10 CFR 36.33 - Irradiator pools.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... purification system designed to be capable of maintaining the water during normal operation at a conductivity..., irradiator pools must either: (1) Have a water-tight stainless steel liner or a liner metallurgically... water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter...

  18. 10 CFR 36.33 - Irradiator pools.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... purification system designed to be capable of maintaining the water during normal operation at a conductivity..., irradiator pools must either: (1) Have a water-tight stainless steel liner or a liner metallurgically... water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter...

  19. 10 CFR 36.33 - Irradiator pools.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... purification system designed to be capable of maintaining the water during normal operation at a conductivity..., irradiator pools must either: (1) Have a water-tight stainless steel liner or a liner metallurgically... water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter...

  20. 10 CFR 36.33 - Irradiator pools.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... purification system designed to be capable of maintaining the water during normal operation at a conductivity..., irradiator pools must either: (1) Have a water-tight stainless steel liner or a liner metallurgically... water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter...

  1. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  2. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  3. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  4. Advances in chest drain management in thoracic disease

    PubMed Central

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  5. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rozemeijer, J. C.; Visser, A.; Borren, W.

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates andmore » the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007–2008) and after (2009–2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. Furthermore, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.« less

  6. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    DOE PAGES

    Rozemeijer, J. C.; Visser, A.; Borren, W.; ...

    2016-01-19

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates andmore » the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007–2008) and after (2009–2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. Furthermore, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.« less

  7. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J. C.; Visser, A.; Borren, W.; Winegram, M.; van der Velde, Y.; Klein, J.; Broers, H. P.

    2016-01-01

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates and the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007-2008) and after (2009-2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. However, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.

  8. Control of crystal growth in water purification by directional freeze crystallization

    NASA Technical Reports Server (NTRS)

    Conlon, William M. (Inventor)

    1996-01-01

    A Directional Freeze Crystallization system employs an indirect contact heat exchanger to freeze a fraction of liquid to be purified. The unfrozen fraction is drained away and the purified frozen fraction is melted. The heat exchanger must be designed in accordance with a Growth Habit Index to achieve efficient separation of contaminants. If gases are dissolved in the liquid, the system must be pressurized.

  9. In Situ Corrosion and Heat Loss Assessment of Two Nonstandard Underground Heat Distribution System Piping Designs: Supplement-Appendices for Final Report on Project F07-AR01

    DTIC Science & Technology

    2011-06-01

    negative mission impacts . This report documents the assessment of two similar nonstandard UHDS piping system designs — one at Fort Carson, CO, and one at...psig and monitored for 2 hours to determine whether the conduit piping system is protected from ground water infiltration and its degrading impacts ...Conduits to/from this pit were tested from adjacent pits. 2. Supply, Return drains tested on 8/15/07: All Dry N S EW MH-3N ERDC/CERL TR-11-14 H13

  10. Improved simulation of poorly drained forests using Biome-BGC.

    PubMed

    Bond-Lamberty, Ben; Gower, Stith T; Ahl, Douglas E

    2007-05-01

    Forested wetlands and peatlands are important in boreal and terrestrial biogeochemical cycling, but most general-purpose forest process models are designed and parameterized for upland systems. We describe changes made to Biome-BGC, an ecophysiological process model, that improve its ability to simulate poorly drained forests. Model changes allowed for: (1) lateral water inflow from a surrounding watershed, and variable surface and subsurface drainage; (2) adverse effects of anoxic soil on decomposition and nutrient mineralization; (3) closure of leaf stomata in flooded soils; and (4) growth of nonvascular plants (i.e., bryophytes). Bryophytes were treated as ectohydric broadleaf evergreen plants with zero stomatal conductance, whose cuticular conductance to CO(2) was dependent on plant water content. Individual model changes were parameterized with published data, and ecosystem-level model performance was assessed by comparing simulated output to field data from the northern BOREAS site in Manitoba, Canada. The simulation of the poorly drained forest model exhibited reduced decomposition and vascular plant growth (-90%) compared with that of the well-drained forest model; the integrated bryophyte photosynthetic response accorded well with published data. Simulated net primary production, biomass and soil carbon accumulation broadly agreed with field measurements, although simulated net primary production was higher than observed data in well-drained stands. Simulated net primary production in the poorly drained forest was most sensitive to oxygen restriction on soil processes, and secondarily to stomatal closure in flooded conditions. The modified Biome-BGC remains unable to simulate true wetlands that are subject to prolonged flooding, because it does not track organic soil formation, water table changes, soil redox potential or anaerobic processes.

  11. EVALUATION OF FABRIC MEMBRANES FOR USE IN SALTSTONE DRAIN WATER SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickenheim, B.; Miller, D.; Burket, P.

    2012-03-08

    Saltstone Disposal Unit 2 contains a sheet drain fabric intended to separate solids from drain water to be returned to the Salt Feed Tank. A similar system installed in Vault 4 appears to be ineffective in keeping solids out of the drain water return lines. Waste Solidification Engineering is considering installation of an additional fabric membrane to supplement the existing sheet drain in SDU 2. Amerdrain 200 is the product currently installed in SDU 2. This product is no longer available, so Sitedrain 94 was used as the replacement product in this testing. Fabrics with apparent opening sizes of 10,more » 25, 50 and 100 microns were evaluated. These fabrics were evaluated under three separate test conditions, a water flow test, a solids retention test and a grout pour test. A flow test with water showed that installation of an additional filter layer will predictably reduce the theoretical flux through the sheet drain. The manufacturer reports the flux for Sitedrain 94 as 150 gpm/ft{sup 2} by ASTM D-4491. This compares reasonably well with the 117 gpm/ft{sup 2} obtained in this testing. A combination of the 10 micron fabric with Sitedrain 94 could be expected to decrease flux by about 10 times as compared to Sitedrain 94 alone. The different media were used to filter a slag and fly ash mixture from water. Slag historically has the smallest nominal particle size of the premix components. Cement was omitted from the test because of its reactivity with water would prohibit accurately particle size measurements of the filtered samples. All four media sizes were able to remove greater than 95% of particles larger than 100 microns from the slurry. The smaller opening sizes were increasingly effective in removing more particles. The 10 micron filter captured 15% of the total amount of solids used in the test. This result implies that some insoluble particles may still be able to enter the drain water collection system, although the overall solids rejection is significantly improved over the current design. Test boxes were filled with grout to evaluate the performance of the sheet drain and fabrics in a simulated vault environment. All of the tests produced a similar amount of drain water, between 8-11% of the amount of water in the mix, which is expected with the targeted formulation. All of the collected drain waters contained some amount of solids, although the 10 micron filter did not appear to allow any premix materials to pass through. The solids collected from this box are believed to consist of calcium carbonate based on one ICP-AES measurement. Any of the four candidate fabrics would be an improvement over the sheet drain alone relative to solids removal. The 10 micron fabric is the only candidate that stopped all premix material from passing. The 10 micron fabric will also cause the largest decrease in flux. This decrease in flux was not enough to inhibit the total amount of drain water removed, but may lead to increased time to remove standing water prior to subsequent pours in the facility. The acceptability of reduced liquid flux through the 10 micron fabric will depend on the amount of excess water to be removed, the time available for water removal and the total area of fabric installed at the disposal cell.« less

  12. Enhancement of capacitance benefit by drain offset structure in tunnel field-effect transistor circuit speed associated with tunneling probability increase

    NASA Astrophysics Data System (ADS)

    Asai, Hidehiro; Mori, Takahiro; Matsukawa, Takashi; Hattori, Junichi; Endo, Kazuhiko; Fukuda, Koichi

    2018-04-01

    The effect of a drain offset structure on the operation speed of a tunnel field-effect transistor (TFET) ring oscillator is investigated by technology computer-aided design (TCAD) simulation. We demonstrate that the reduction of gate-drain capacitance by the drain offset structure dramatically increases the operation speed of the ring oscillators. Interestingly, we find that this capacitance benefit to operation speed is enhanced by the increase in band-to-band tunneling probability. The “synergistic” speed enhancement by the drain offset structure and the tunneling rate increase will have promising application to the significant improvement of the operation speed of TFET circuits.

  13. Nutrient Drain Associated with Hardwood Plantation Culture

    Treesearch

    James B. Baker

    1978-01-01

    Past research and a tentative evaluation indicate that nutrient drain and possible site degradation could occur in southern hardwood plantations. The extent of nutrient drain on a given site would depend on the species, length of the rotation, and harvesting system used. The evaluation for cottonwood plantations in Mississippi indicates that nutrient drain is most...

  14. Effects of Land Use of the Hydrology of Drained Coastal Plain Watersheds

    Treesearch

    R. Wayne Skaggs; George M Chescheir; Glen P. Fernandez; Devendra M. Amatya

    2004-01-01

    Some of the world's most productive cropland requires artificial or improved drainage for efficient agricultural production. Soil hydraulic properties, such as hydraulicconductivity and drainable porosity, are conventionally used in design of drainage systems. While it is recognized that these soil properties vary over a relatively wide range within a given soil...

  15. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in..., turbine casings, exhaust piping and shutoff valves, is not designed for the full inlet pressure, the... must be provided for draining every steam pipe in which dangerous water hammer might otherwise occur...

  16. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in..., turbine casings, exhaust piping and shutoff valves, is not designed for the full inlet pressure, the... must be provided for draining every steam pipe in which dangerous water hammer might otherwise occur...

  17. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in..., turbine casings, exhaust piping and shutoff valves, is not designed for the full inlet pressure, the... must be provided for draining every steam pipe in which dangerous water hammer might otherwise occur...

  18. 46 CFR 56.50-15 - Steam and exhaust piping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... hot water for heating systems may not exceed 375 °F. (i) Where positive shutoff valves are fitted in..., turbine casings, exhaust piping and shutoff valves, is not designed for the full inlet pressure, the... must be provided for draining every steam pipe in which dangerous water hammer might otherwise occur...

  19. Prefabricated vertical drains, vol. I : engineering guidelines.

    DOT National Transportation Integrated Search

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal tion of prefabricated vertical drains to accelerate consolidation of soils. The contents represent the Consultant's interpretation of the state-of-the-art as of August...

  20. Environmental Education: Non-point Source Pollution

    EPA Pesticide Factsheets

    This activity is designed to demonstrate to students what an average storm drain collects during a rainfall event and how the water from storm drains can impact the water quality and aquatic environments of local streams, rivers, and bays.

  1. Media filter drain : modified design evaluation.

    DOT National Transportation Integrated Search

    2014-09-01

    The media filter drain (MFD), a stormwater water quality treatment best management practice, consists of media made up of : aggregate, perlite, gypsum and dolomite in a trench located along roadway shoulders with gravel and vegetative pre-filtering f...

  2. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  3. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  4. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  5. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  6. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  7. Effects of drain bias on the statistical variation of double-gate tunnel field-effect transistors

    NASA Astrophysics Data System (ADS)

    Choi, Woo Young

    2017-04-01

    The effects of drain bias on the statistical variation of double-gate (DG) tunnel field-effect transistors (TFETs) are discussed in comparison with DG metal-oxide-semiconductor FETs (MOSFETs). Statistical variation corresponds to the variation of threshold voltage (V th), subthreshold swing (SS), and drain-induced barrier thinning (DIBT). The unique statistical variation characteristics of DG TFETs and DG MOSFETs with the variation of drain bias are analyzed by using full three-dimensional technology computer-aided design (TCAD) simulation in terms of the three dominant variation sources: line-edge roughness (LER), random dopant fluctuation (RDF) and workfunction variation (WFV). It is observed than DG TFETs suffer from less severe statistical variation as drain voltage increases unlike DG MOSFETs.

  8. Drain placement can be safely omitted after the majority of robotic partial nephrectomies.

    PubMed

    Abaza, Ronney; Prall, David

    2013-03-01

    Drain placement after partial nephrectomy is considered standard but it is based on routine and not on evidence. With experience we performed robotic partial nephrectomy and routinely omitted a drain even with significant collecting system violation. We have rarely used drains after robotic partial nephrectomy for several years, and we report our outcomes. We reviewed a single surgeon, prospective database of all robotic partial nephrectomies from February 2008 to March 2012, including the characteristics of those with and without a drain. The 150 patients underwent a total of 160 robotic partial nephrectomy procedures with a drain used in 11 patients and omitted in 93%. Mean patient age was 57 years (range 22 to 89), mean American Society of Anesthesiologists score was 2.8 (range 2 to 4) and mean body mass index was 32 kg/m(2) (range 18 to 54). Values were similar in patients with and without a drain. In patients without a drain and in those with a drain mean tumor size was 3.5 cm (range 1.0 to 11.0) and 4.6 cm (range 1.1 to 8.6), and mean R.E.N.A.L. (radius, exophytic/endophytic, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines, hilar tumor touching main renal artery or vein) nephrometry score was 7.8 (range 4 to 12) and 8.8 (range 6 to 11), respectively. Collecting system violation occurred in 88 patients (59%), including 78 without a drain. Two patients (1.3%) required transfusion with no intervention for bleeding. All except 5 patients (97%) were discharged home on postoperative day 1 with all drains removed before discharge. In 2 patients (1.3%) without a drain small urinomas without infection developed more than 2 weeks postoperatively, which were treated with a week of Foley catheter drainage and percutaneous drainage, respectively. Drain placement after robotic partial nephrectomy can be routinely omitted with a low rate of urine leaks, which can be managed safely when they rarely occur. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Design guidelines for horizontal drains used for slope stabilization.

    DOT National Transportation Integrated Search

    2013-03-01

    The presence of water is one of the most critical factors contributing to the instability of hillslopes. A common : solution to stabilize hillslopes is installation of horizontal drains to decrease the elevation of the water table : surface. Lowering...

  10. Post-Outbreak Investigation of Pseudomonas aeruginosa Faucet Contamination by Quantitative Polymerase Chain Reaction and Environmental Factors Affecting Positivity.

    PubMed

    Bédard, Emilie; Laferrière, Céline; Charron, Dominique; Lalancette, Cindy; Renaud, Christian; Desmarais, Nadia; Déziel, Eric; Prévost, Michèle

    2015-11-01

    To perform a post-outbreak prospective study of the Pseudomonas aeruginosa contamination at the faucets (water, aerator and drain) by culture and quantitative polymerase chain reaction (qPCR) and to assess environmental factors influencing occurrence A 450-bed pediatric university hospital in Montreal, Canada Water, aerator swab, and drain swab samples were collected from faucets and analyzed by culture and qPCR for the post-outbreak investigation. Water microbial and physicochemical parameters were measured, and a detailed characterization of the sink environmental and design parameters was performed. The outbreak genotyping investigation identified drains and aerators as the source of infection. The implementation of corrective measures was effective, but post-outbreak sampling using qPCR revealed 50% positivity for P. aeruginosa remaining in the water compared with 7% by culture. P. aeruginosa was recovered in the water, the aerator, and the drain in 21% of sinks. Drain alignment vs the faucet and water microbial quality were significant factors associated with water positivity, whereas P. aeruginosa load in the water was an average of 2 log higher for faucets with a positive aerator. P. aeruginosa contamination in various components of sink environments was still detected several years after the resolution of an outbreak in a pediatric university hospital. Although contamination is often not detectable in water samples by culture, P. aeruginosa is present and can recover its culturability under favorable conditions. The importance of having clear maintenance protocols for water systems, including the drainage components, is highlighted.

  11. Water movement and isoproturon behaviour in a drained heavy clay soil: 1. Preferential flow processes

    NASA Astrophysics Data System (ADS)

    Haria, A. H.; Johnson, A. C.; Bell, J. P.; Batchelor, C. H.

    1994-12-01

    The processes and mechanisms that control pesticide transport from drained heavy clay catchments are being studied at Wytham Farm (Oxford University) in southern England. In the first field season field-drain water contained high concentrations of pesticide. Soil studies demonstrated that the main mechanism for pesticide translocation was by preferential flow processes, both over the soil surface and through the soil profile via a macropore system that effectively by-passed the soil matrix. This macropore system included worm holes, shrinkage cracks and cracks resulting from ploughing. Rainfall events in early winter rapidly created a layer of saturation in the A horizon perched above a B horizon of very low hydraulic conductivity. Drain flow was initiated when the saturated layer in the A horizon extended into the upper 0.06m of the soil profile; thereafter water moved down slope via horizontal macropores possibly through a band of incorporated straw residues. These horizontal pathways for water movement connected with the fracture system of the mole drains, thus feeding the drains. Overland flow occurred infrequently during the season.

  12. Promoting nitrate removal in rain gardens | Science Inventory ...

    EPA Pesticide Factsheets

    Rain gardens are vegetated surface depressions, often located at low points in landscapes, designed to receive stormwater runoff from roads, roofs, and parking lots. The gardens’ sandy soils allow stormwater to drain quickly to the native soils below and eventually to groundwater. The rain garden vegetation and soils remove pollutants and nutrients from stormwater runoff through biological and physical processes such as plant uptake and sorption to soil particles. In comparison with stormwater release to receiving waters through conventional storm drain systems, infiltrating stormwater through rain gardens reduces peak flows and loadings of both pollutants and nutrients. This reduction improves the physical and biological integrity of receiving streams by reducing stream bank erosion and negative effects on stream communities. While local governments and individual homeowners are building these systems, relatively few scientific studies have documented the ability of rain gardens to remove pollutants and nutrients. This U.S. EPA long-term research project investigates: 1) the performance of rain gardens in removing pollutants, and 2) whether currently-accepted design standards can be adjusted to improve nitrate removal capabilities. Typical rain garden designs provide large removals of pollutants of concern, including heavy metals, phosphorus, total nitrogen, and ammonium. The gardens have been less successful in removing nitrate, an importan

  13. CUA Annual Meeting Abstracts addition.

    PubMed

    2012-08-01

    : Foley catheters are assumed to drain the bladder to completion. We have previously shown that dependent loops along the drainage tubing create air-locks, which obstruct antegrade urine flow and result in un-drained residual bladder urine. We hypothesized that drainage characteristics of Foley catheters remain poorly understood by urologists and general surgeons. We conducted a nationwide survey of general surgery and urology training program faculty and residents, to assess perceptions of Foley catheter drainage. We designed a novel catheter drainage tube/bag that eliminates air-locks. : An anonymous illustrated questionnaire assessing Foley catheter use patterns and perception was sent to general surgery and urology residency programs (N=108) nationwide. A modified catheter drainage tube/bag unit was designed and tested. An ex vivo catheterized bladder model was designed to measure and compare urine drainage rates with the standard drainage system, versus with our novel design. : A total of 307 responses were collected from residents (55%) and faculty (45%); responses were similar among both groups (p<0.05). The majority reported that at their centers Foley catheter drainage tubes are generally positioned with a dependent loop (94.1%), and, that positioning with a dependent loop, versus without (78.1%) promoted optimal drainage. Antegrade drainage does not occur with a traditional drainage system when a >5.5 inch dependent loop in place. With our proposed design, which eliminates dependent loops, the bladder model emptied to completion consistently. : Traditional Foley catheter drainage systems, as commonly used, evacuate the bladder sub- optimally. More reliable and complete bladder drainage may decrease the incidence of catheter related UTI. The novel modified Foley catheter drainage tube/bag design presented here eliminates dependent loops, to optimize antegrade drainage.

  14. The 10 MWe Solar Thermal Central Receiver Pilot Plant: Solar facilities design integration. Pilot-plant station manual (RADL Item 2-1). Volume 1: System description

    NASA Astrophysics Data System (ADS)

    1982-09-01

    The complete Barstow Solar Pilot Plant is described. The plant requirements and general description are presented, the mechanical, electric power, and control and instrumentation systems as well as civil engineering and structural aspects and the station buildings are described. Included in the mechanical systems are the heliostats, receiver, thermal storage system, beam characterization system, steam, water, nitrogen, and compressed air systems, chemical feed system, fire protection system, drains, sumps and the waste disposal systems, and heating, ventilating, and air conditioning systems.

  15. Si1-yGey or Ge1-zSnz Source/Drain Stressors on Strained Si1-xGex-Channel P-Type Field-Effect Transistors: A Technology Computer-Aided Design Study

    NASA Astrophysics Data System (ADS)

    Eneman, Geert; De Keersgieter, An; Witters, Liesbeth; Mitard, Jerome; Vincent, Benjamin; Hikavyy, Andriy; Loo, Roger; Horiguchi, Naoto; Collaert, Nadine; Thean, Aaron

    2013-04-01

    The interaction between two stress techniques, strain-relaxed buffers (SRBs) and epitaxial source/drain stressors, is studied on short, Si1-xGex- and Ge-channel planar transistors. This work focuses on the longitudinal channel stress generated by these two techniques. Unlike for unstrained silicon-channel transistors, for strained channels on top of a strain-relaxed buffer a source/drain stressor without recess generates similar longitudinal channel stress than source/drain stressors with a deep recess. The least efficient stress transfer is obtained for source/drain stressors with a small recess that removes only the strained channel, not the substrate underneath. These trends are explained by a trade-off between elastic relaxation of the strained-channel during source/drain recess and the increased stress generation of thicker source/drain stressors. For Ge-channel pFETs, GeSn source/drains and Si1-xGex strain-relaxed buffers are efficient stressors for mobility enhancement. The former is more efficient for gate-last schemes than for gate-first, while the stress generated by the SRB is found to be independent of the gate-scheme.

  16. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    PubMed Central

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of <10 years, low-rank nurses and those working in the female medical ward; however, the relationship cant (P > 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  17. Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces.

    PubMed

    Benton, Ian J; Benfield, Grant F A

    2009-10-01

    To compare treatment success of large- and small-bore chest drains in the treatment of spontaneous pneumothoraces the case-notes were reviewed of those admitted to our hospital with a total of 73 pneumothoraces and who were treated by trainee doctors of varying experience. Both a large- and a small-bore intercostal tube drain system were in use during the two-year period reviewed. Similar pneumothorax profile and numbers treated with both drains were recorded, resulting in a similar drain time and numbers of successful and failed re-expansion of pneumothoraces. Successful pneumothorax resolution was the same for both drain types and the negligible tube drain complications observed with the small-bore drain reflected previously reported experiences. However the large-bore drain was associated with a high complication rate (32%) with more infectious complications (24%). The small-bore drain was prone to displacement (21%). There was generally no evidence of an increased failure and morbidity, reflecting poorer expertise, in the non-specialist trainees managing the pneumothoraces. A practical finding however was that in those large pneumothoraces where re-expansion failed, the tip of the drain had not been sited at the apex of the pleural cavity irrespective of the drain type inserted.

  18. Sloshing in the Liquid Hydrogen and Liquid Oxygen Propellant Tanks After Main Engine Cut Off

    NASA Technical Reports Server (NTRS)

    Kim, Sura; West, Jeff

    2011-01-01

    NASA Marshall Space Flight Center is designing and developing the Main Propulsion System (MPS) for Ares launch vehicles. Propellant sloshing in the liquid hydrogen (LH2) and liquid oxygen (LO2) propellant tanks after Main Engine Cut Off (MECO) was modeled using the Volume of Fluid (VOF) module of the computational fluid dynamics code, CFD-ACE+. The present simulation shows that there is substantial sloshing side forces acting on the LH2 tank during the deceleration of the vehicle after MECO. The LH2 tank features a side wall drain pipe. The side loads result from the residual propellant mass motion in the LH2 tank which is initiated by the stop of flow into the drain pipe at MECO. The simulations show that radial force on the LH2 tank wall is less than 50 lbf and the radial moment calculated based up through the center of gravity of the vehicle is predicted to be as high as 300 lbf-ft. The LO2 tank features a bottom dome drain system and is equipped with sloshing baffles. The remaining LO2 in the tank slowly forms a liquid column along the centerline of tank under the zero gravity environments. The radial force on the LO2 tank wall is predicted to be less than 100 lbf. The radial moment calculated based on the center of gravity of the vehicle is predicted as high as 4500 lbf-ft just before MECO and dropped down to near zero after propellant draining stopped completely.

  19. Accuracy of surgical wound drainage measurements: an analysis and comparison.

    PubMed

    Yue, Brian; Nizzero, Danielle; Zhang, Chunxiao; van Zyl, Natasha; Ting, Jeannette

    2015-05-01

    Surgical drain tube readings can influence the clinical management of the post-operative patient. The accuracy of these readings has not been documented in the current literature and this experimental study aims to address this paucity. Aliquots (10, 25, 40 and 90 mL) of black tea solution prepared to mimic haemoserous fluid were injected into UnoVac, RedoVac and Jackson-Pratt drain tubes. Nursing and medical staff from a tertiary hospital were asked to estimate drain volumes by direct observation; analysis of variance was performed on the results and significance level was set at 0.05. Doctors and nurses are equally accurate in estimating drain tube volumes. Jackson-Pratt systems were found to be the most accurate for intermediate volumes of 25 and 40 mL. For extreme of volumes (both high and low), all drainage systems were inaccurate. This study suggests that for intermediate volumes (25 and 40 mL), Jackson-Pratt is the drainage system of choice. The accuracy of volume measurement is diminished at the extremes of drain volumes; emptying of drainage systems is recommended to avoid overfilling of drainage systems. © 2014 Royal Australasian College of Surgeons.

  20. The New NASA-STD-4005 and NASA-HDBK-4006, Essentials for Direct-Drive Solar Electric Propulsion

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.

    2007-01-01

    High voltage solar arrays are necessary for direct-drive solar electric propulsion, which has many advantages, including simplicity and high efficiency. Even when direct-drive is not used, the use of high voltage solar arrays leads to power transmission and conversion efficiencies in electric propulsion Power Management and Distribution. Nevertheless, high voltage solar arrays may lead to temporary power disruptions, through the so-called primary electrostatic discharges, and may permanently damage arrays, through the so-called permanent sustained discharges between array strings. Design guidance is needed to prevent these solar array discharges, and to prevent high power drains through coupling between the electric propulsion devices and the high voltage solar arrays. While most electric propulsion systems may operate outside of Low Earth Orbit, the plasmas produced by their thrusters may interact with the high voltage solar arrays in many ways similarly to Low Earth Orbit plasmas. A brief description of previous experiences with high voltage electric propulsion systems will be given in this paper. There are two new official NASA documents available free through the NASA Standards website to help in designing and testing high voltage solar arrays for electric propulsion. They are NASA-STD-4005, the Low Earth Orbit Spacecraft Charging Design Standard, and NASA-HDBK-4006, the Low Earth Orbit Spacecraft Charging Design Handbook. Taken together, they can both educate the high voltage array designer in the engineering and science of spacecraft charging in the presence of dense plasmas and provide techniques for designing and testing high voltage solar arrays to prevent electrical discharges and power drains.

  1. Evaluation of the Environmental Fate of Munition Compounds in Soil.

    DTIC Science & Technology

    1979-06-01

    temperature in- duction furnace. Nitrate Water samples were analyzed for nitrate (NO:T) by a Dion -X System Ten ion chromatograph. Nitrite Water samples...moderately well drained Celins , somewhat poorly drained Crosby and Conover, and very poorly drained Kokomo form a drainage sequence with the

  2. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil system drains. 121.241 Section 121.241 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... position, must be provided to allow safe drainage of the entire oil system. ...

  3. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oil system drains. 121.241 Section 121.241 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... position, must be provided to allow safe drainage of the entire oil system. ...

  4. Novel technique of source and drain engineering for dual-material double-gate (DMDG) SOI MOSFETS

    NASA Astrophysics Data System (ADS)

    Yadav, Himanshu; Malviya, Abhishek Kumar; Chauhan, R. K.

    2018-04-01

    The dual-metal dual-gate (DMDG) SOI has been used with Dual Sided Source and Drain Engineered 50nm SOI MOSFET with various high-k gate oxide. It has been scrutinized in this work to enhance its electrical performance. The proposed structure is designed by creating Dual Sided Source and Drain Modification and its characteristics are evaluated on ATLAS device simulator. The consequence of this dual sided assorted doping on source and drain side of the DMDG transistor has better leakage current immunity and heightened ION current with higher ION to IOFF Ratio. Which thereby vesting the proposed device appropriate for low power digital applications.

  5. Determination and prioritization of MoDOT geotechnical related problems with emphasis on effectiveness of design for bridge approach slabs and pavement edge drains

    DOT National Transportation Integrated Search

    2003-01-01

    Surveys, interviews and site visits were used to identify, observe and document geotechnical-related problems in Missouri DOT infrastructure. Documented issues were evaluated and prioritized. Additional attention was focused on Pavement Edge Drains a...

  6. Frequency dependence and passive drains in fish-eye lenses

    NASA Astrophysics Data System (ADS)

    Quevedo-Teruel, O.; Mitchell-Thomas, R. C.; Hao, Y.

    2012-11-01

    The Maxwell fish eye lens has previously been reported as being capable of the much sought after phenomenon of subwavelength imaging. The inclusion of a drain in this system is considered crucial to the imaging ability, although its role is the topic of much debate. This paper provides a numerical investigation into a practical implementation of a drain in such systems, and analyzes the strong frequency dependence of both the Maxwell fish eye lens and an alternative, the Miñano lens. The imaging capability of these types of lens is questioned, and it is supported by simulations involving various configurations of drain arrays. Finally, a discussion of the near-field and evanescent wave contribution is given.

  7. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil system drains. 125.139 Section 125.139 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  8. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oil system drains. 125.139 Section 125.139 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  9. Design and performance of limestone drains to increase pH and remove metals from acidic mine drainage, Chapter 2

    USGS Publications Warehouse

    Cravotta,, Charles A.; Watzlaf, George R.

    2002-01-01

    Data on the construction characteristics and the composition of influent and effluent at 13 underground, limestone-filled drains in Pennsylvania and Maryland are reported to evaluate the design and performance of limestone drains for the attenuation of acidity and dissolved metals in acidic mine drainage. On the basis of the initial mass of limestone, dimensions of the drains, and average flow rates, the initial porosity and average detention time for each drain were computed. Calculated porosity ranged from 0.12 to 0.50 with corresponding detention times at average flow from 1.3 to 33 h. The effectiveness of treatment was dependent on influent chemistry, detention time, and limestone purity. At two sites where influent contained elevated dissolved Al (>5 mg/liter), drain performance declined rapidly; elsewhere the drains consistently produced near-neutral effluent, even when influent contained small concentrations of dissolved Fe^+ (<5 mg/liter). Rates of limestone dissolution computed on the basis of average long-term Ca ion flux normalized by initial mass and purity of limestone at each of the drains ranged from 0.008 to 0.079 year-1. Data for alkalinity concentration and flux during 11-day closed-container tests using an initial mass of 4kg crushed limestone and a solution volume of 2.3 liter yielded dissolution rate constants that were comparable to these long-term field rates. An analytical method is proposed using closed-container test data to evaluate long-term performance (longevity) or to estimate the mass of limestone needed for a limestone treatment. This method condisers flow rate, influent alkalinity, steady-state alkalinity of effluent, and desired effluent alkalinity or detention time at a future time(s) and aplies first-order rate laws for limestone dissolution (continuous) and production of alkalinity (bounded).

  10. Corrective Action Plan for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2011-04-30

    This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 562, Waste Systems, in accordance with the Federal Facility Agreement and Consent Order (1996; as amended March 2010). CAU 562 consists of 13 Corrective Action Sites (CASs) located in Areas 2, 23, and 25 of the Nevada National Security Site. Site characterization activities were performed in 2009 and 2010, and the results are presented in Appendix A of the Corrective Action Decision Document for CAU 562. The scope of work required to implement the recommended closure alternatives is summarized. (1) CAS 02-26-11, Lead Shot, will be clean closedmore » by removing shot. (2) CAS 02-44-02, Paint Spills and French Drain, will be clean closed by removing paint and contaminated soil. As a best management practice (BMP), asbestos tile will be removed. (3) CAS 02-59-01, Septic System, will be clean closed by removing septic tank contents. As a BMP, the septic tank will be removed. (4) CAS 02-60-01, Concrete Drain, contains no contaminants of concern (COCs) above action levels. No further action is required; however, as a BMP, the concrete drain will be removed. (5) CAS 02-60-02, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. As a BMP, the drain grates and drain pipe will be removed. (6) CAS 02-60-03, Steam Cleaning Drain, will be clean closed by removing contaminated soil. As a BMP, the steam cleaning sump grate and outfall pipe will be removed. (7) CAS 02-60-04, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. (8) CAS 02-60-05, French Drain, will be clean closed by removing contaminated soil. (9) CAS 02-60-06, French Drain, contains no COCs above action levels. No further action is required. (10) CAS 02-60-07, French Drain, requires no further action. The french drain identified in historical documentation was not located during corrective action investigation activities. (11) CAS 23-60-01, Mud Trap Drain and Outfall, will be clean closed by removing sediment from the mud trap. As a BMP, the mud trap and outfall pipe will be removed. (12) CAS 23-99-06, Grease Trap, will be clean closed by removing sediment from the grease trap and backfilling the grease trap with grout. (13) CAS 25-60-04, Building 3123 Outfalls, will be clean closed by removing contaminated soil and the sludge-containing outfall pipe.« less

  11. Two cases of left superior vena cava draining directly to a left atrium with a normal coronary sinus.

    PubMed Central

    Wiles, H B

    1991-01-01

    The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125

  12. Greenhouse gas fluxes of drained organic and flooded mineral agricultural soils in the United States

    USDA-ARS?s Scientific Manuscript database

    Drained organic soils for agriculture represent less than 1% of the area used for crops in the United States (US). However, emission of carbon dioxide (CO2) from microbial oxidation of drained organic soils offsets almost half of the contributions that carbon sequestration of other cropping systems ...

  13. Lithium Circuit Test Section Design and Fabrication

    NASA Technical Reports Server (NTRS)

    Godfroy, Thomas; Garber, Anne

    2006-01-01

    The Early Flight Fission - Test Facilities (EFF-TF) team has designed and built an actively pumped lithium flow circuit. Modifications were made to a circuit originally designed for NaK to enable the use of lithium that included application specific instrumentation and hardware. Component scale freeze/thaw tests were conducted to both gain experience with handling and behavior of lithium in solid and liquid form and to supply anchor data for a Generalized Fluid System Simulation Program (GFSSP) model that was modified to include the physics for freeze/thaw transitions. Void formation was investigated. The basic circuit components include: reactor segment, lithium to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and trace heaters. This paper will discuss the overall system design and build and the component testing findings.

  14. Lithium Circuit Test Section Design and Fabrication

    NASA Astrophysics Data System (ADS)

    Godfroy, Thomas; Garber, Anne; Martin, James

    2006-01-01

    The Early Flight Fission - Test Facilities (EFF-TF) team has designed and built an actively pumped lithium flow circuit. Modifications were made to a circuit originally designed for NaK to enable the use of lithium that included application specific instrumentation and hardware. Component scale freeze/thaw tests were conducted to both gain experience with handling and behavior of lithium in solid and liquid form and to supply anchor data for a Generalized Fluid System Simulation Program (GFSSP) model that was modified to include the physics for freeze/thaw transitions. Void formation was investigated. The basic circuit components include: reactor segment, lithium to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and trace heaters. This paper discusses the overall system design and build and the component testing findings.

  15. Control systems for heating, ventilating, and air conditioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haines, R.W.

    1977-01-01

    Hundreds of ideas for designing and controlling sophisticated heating, ventilating and air conditioning (HVAC) systems are presented. Information is included on enthalpy control, energy conservation in HVAC systems, on solar heating, cooling and refrigeration systems, and on a self-draining water collector and heater. Computerized control systems and the economics of supervisory systems are discussed. Information is presented on computer system components, software, relevant terminology, and computerized security and fire reporting systems. Benefits of computer systems are explained, along with optimization techniques, data management, maintenance schedules, and energy consumption. A bibliography, glossaries of HVAC terminology, abbreviations, symbols, and a subject indexmore » are provided. (LCL)« less

  16. Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

  17. Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

  18. Thoracic Trauma: Which Chest Tube When and Where?

    PubMed

    Molnar, Tamas F

    2017-02-01

    Clinical suspicion of hemo/pneumothorax: when in doubt, drain the chest. Stable chest trauma with hemo/pneumothorax: drain and wait. Unstable patient with dislocated trachea must be approached with drain in hand and scalpel ready. Massive hemo/pneumothorax may be controlled by drainage alone. The surgeon should not hesitate to open the chest if too much blood drains over a short period. The chest drainage procedure does not end with the last stitch; the second half of the match is still ahead. The drained patient is in need of physiotherapy and proper pain relief with an extended pleural space: control the suction system. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Autotransfusion after total knee arthroplasty. Effects on blood cells, plasma chemistry, and whole blood rheology.

    PubMed

    Dalén, T; Broström, L A; Engström, K G

    1997-08-01

    Postoperative drain blood was collected and reinfused using the ConstaVac system (Stryker, Kalamazoo, MI) in 30 patients after total knee arthroplasty. Of the total 1.1-L volume of postoperative bleeding, 60% was reinfused. No clinical complications were observed. Differences between venous blood and drain blood and between venous blood and drain blood after separate incubation were studied with respect to acidic and inflammatory effects on blood cells, plasma chemistry, and whole blood rheology. In drain blood, leukocyte and platelet counts were reduced (P < .001), probably as a result of consumption in the wound. Acidic incubation occurs in the drain container because of production of lactate from glucose, with a minimum pH at 5 hours of 7.2. The low pH caused slight but significant erythrocyte swelling (P < .01). The complement C3d indicated leukocyte activation, although of modest magnitude. Despite incubation and complement activation, maximum erythrocyte hemolysis after 24 hours of incubation was less than 1%. Drain blood showed a lower resistance against micropore filtration than venous blood (P < .001), mainly because of the reduced number of leukocytes, and remained unchanged with incubation. Although the autotransfusion system can be improved with respect to blood quality, filtered drain blood should be considered acceptable for reinfusion.

  20. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    PubMed

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P < 0.05). The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  1. A comparative study of surgical drain placement and the use of kinesiologic tape to reduce postoperative morbidity after third molar surgery.

    PubMed

    Genc, Aysenur; Cakarer, Sirmahan; Yalcin, Basak Keskin; Kilic, Beril Berivan; Isler, Sabri Cemil; Keskin, Cengizhan

    2018-04-19

    Our aim was to compare the effects of the surgical drain and kinesiotape applications on postoperative morbidity after mandibular third molar surgery in a split-mouth study design. A single-centre, split-mouth study was performed in 23 patients who needed surgical removal of bilateral mandibular third molars. Each patient was treated with a drain tube on one side of the mandible and Kinesio tape (KT) on the contralateral side. Swelling was significantly greater in the KT group than in the drain group throughout the study period. The groups did not differ significantly in the amount of trismus at any time point. The Visual Analogue Scale (VAS)-measured pain intensity was significantly lower in the drainage group. Patients with KT had greater postoperative discomfort than those with a drain tube. All patients were generally satisfied with their treatments. Although both treatments were useful, a surgical drain was significantly more effective at reducing swelling and pain intensity than Kinesio tape. The effects of both on trismus were similar.

  2. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  3. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  4. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  5. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  6. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  7. Drain Current Modulation of a Single Drain MOSFET by Lorentz Force for Magnetic Sensing Application.

    PubMed

    Chatterjee, Prasenjit; Chow, Hwang-Cherng; Feng, Wu-Shiung

    2016-08-30

    This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in size with respect to the metal loop, which ensures that the generated magnetic field is approximately uniform. The change of drain current and change of bulk current per micron device width has been measured. The result shows that the difference drain current is about 145 µA for the maximum applied magnetic field. Such changes occur from the applied Lorentz force to push out the carriers from the channel. Based on the drain current difference, the change in effective mobility has been detected up to 4.227%. Furthermore, a detailed investigation reveals that the device behavior is quite different in subthreshold and saturation region. A change of 50.24 µA bulk current has also been measured. Finally, the device has been verified for use as a magnetic sensor with sensitivity 4.084% (29.6 T(-1)), which is very effective as compared to other previously reported works for a single device.

  8. Perspective analysis of tri gate germanium tunneling field-effect transistor with dopant segregation region at source/drain

    NASA Astrophysics Data System (ADS)

    Liu, Liang-kui; Shi, Cheng; Zhang, Yi-bo; Sun, Lei

    2017-04-01

    A tri gate Ge-based tunneling field-effect transistor (TFET) has been numerically studied with technology computer aided design (TCAD) tools. Dopant segregated Schottky source/drain is applied to the device structure design (DS-TFET). The characteristics of the DS-TFET are compared and analyzed comprehensively. It is found that the performance of n-channel tri gate DS-TFET with a positive bias is insensitive to the dopant concentration and barrier height at n-type drain, and that the dopant concentration and barrier height at a p-type source considerably affect the device performance. The domination of electron current in the entire BTBT current of this device accounts for this phenomenon and the tri-gate DS-TFET is proved to have a higher performance than its dual-gate counterpart.

  9. Linear Test Bed. Volume 2: Test Bed No. 2. [linear aerospike test bed for thrust vector control

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Test bed No. 2 consists of 10 combustors welded in banks of 5 to 2 symmetrical tubular nozzle assemblies, an upper stationary thrust frame, a lower thrust frame which can be hinged, a power package, a triaxial combustion wave ignition system, a pneumatic control system, pneumatically actuated propellant valves, a purge and drain system, and an electrical control system. The power package consists of the Mark 29-F fuel turbopump, the Mark 29-0 oxidizer turbopump, a gas generator assembly, and propellant ducting. The system, designated as a linear aerospike system, was designed to demonstrate the feasibility of the concept and to explore technology related to thrust vector control, thrust vector optimization, improved sequencing and control, and advanced ignition systems. The propellants are liquid oxygen/liquid hydrogen. The system was designed to operate at 1200-psia chamber pressure at an engine mixture ratio of 5.5. With 10 combustors, the sea level thrust is 95,000 pounds.

  10. Effects of groundwater pumping on agricultural drains in the Tule Lake subbasin, Oregon and California

    USGS Publications Warehouse

    Pischel, Esther M.; Gannett, Marshall W.

    2015-07-24

    To better define the effect of increased pumping on drain flow and on the water balance of the groundwater system, the annual water volume pumped from drains in three subareas of the Tule Lake subbasin was estimated and a fine-grid, local groundwater model of the Tule Lake subbasin was constructed. Results of the agricultural-drain flow analysis indicate that groundwater discharge to drains has decreased such that flows in 2012 were approximately 32,400 acre-ft less than the 1997–2000 average flow. This decrease was concentrated in the northern and southeastern parts of the subbasin, which corresponds with the areas of greatest groundwater pumping. Model simulation results of the Tule Lake subbasin groundwater model indicate that increased supplemental pumping is the dominant stress to the groundwater system in the subbasin. Simulated supplemental pumping and decreased recharge from irrigation between 2000 and 2010 totaled 323,573 acre-ft, 234,800 acre-ft (73 percent) of which was from supplemental pumping. The response of the groundwater system to this change in stress included about 180,500 acre-ft (56 percent) of decreased groundwater discharge to drains and a 126,000 acre-ft (39 percent) reduction in aquifer storage. The remaining 5 percent came from reduced groundwater flow to other model boundaries, including the Lost River, the Tule Lake sumps, and interbasin flow.

  11. 29 CFR 1910.126 - Additional requirements for special dipping and coating operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sprinklers; or (ii) An automatic fire-extinguishing system conforming to the requirements of subpart L of... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...

  12. 29 CFR 1910.126 - Additional requirements for special dipping and coating operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sprinklers; or (ii) An automatic fire-extinguishing system conforming to the requirements of subpart L of... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...

  13. Simulation of the hydraulic performance of highway filter drains through laboratory models and stormwater management tools.

    PubMed

    Sañudo-Fontaneda, Luis A; Jato-Espino, Daniel; Lashford, Craig; Coupe, Stephen J

    2017-05-23

    Road drainage is one of the most relevant assets in transport infrastructure due to its inherent influence on traffic management and road safety. Highway filter drains (HFDs), also known as "French Drains", are the main drainage system currently in use in the UK, throughout 7000 km of its strategic road network. Despite being a widespread technique across the whole country, little research has been completed on their design considerations and their subsequent impact on their hydraulic performance, representing a gap in the field. Laboratory experiments have been proven to be a reliable indicator for the simulation of the hydraulic performance of stormwater best management practices (BMPs). In addition to this, stormwater management tools (SMT) have been preferentially chosen as a design tool for BMPs by practitioners from all over the world. In this context, this research aims to investigate the hydraulic performance of HFDs by comparing the results from laboratory simulation and two widely used SMT such as the US EPA's stormwater management model (SWMM) and MicroDrainage®. Statistical analyses were applied to a series of rainfall scenarios simulated, showing a high level of accuracy between the results obtained in laboratory and using SMT as indicated by the high and low values of the Nash-Sutcliffe and R 2 coefficients and root-mean-square error (RMSE) reached, which validated the usefulness of SMT to determine the hydraulic performance of HFDs.

  14. Phosphorus modeling in tile drained agricultural systems using APEX

    USDA-ARS?s Scientific Manuscript database

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  15. Rainfall, discharge, and water-quality data during stormwater monitoring, H-1 storm drain, Oahu, Hawaii, July 1, 2009, to June 30, 2010

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2010-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.

  16. Design of an Orifice and Weir Outlet for Poorly Drained Forested Watersheds

    Treesearch

    D.M. Amatya; R.W. Skaggs; J.H. Hughes

    1999-01-01

    Orifice-weir structures at ditch outlets are being used to reduce peak drainage rates and to store water during the growing season in poorly drained managed pine plantations. Earlier studies have shown their effectiveness on reducing drainage outflows while conserving water during the growing season. This study reports on criteria and preliminary guidelines for...

  17. Inkjet printed graphene-based field-effect transistors on flexible substrate

    NASA Astrophysics Data System (ADS)

    Monne, Mahmuda Akter; Enuka, Evarestus; Wang, Zhuo; Chen, Maggie Yihong

    2017-08-01

    This paper presents the design and fabrication of inkjet printed graphene field-effect transistors (GFETs). The inkjet printed GFET is fabricated on a DuPont Kapton FPC Polyimide film with a thickness of 5 mill and dielectric constant of 3.9 by using a Fujifilm Dimatix DMP-2831 materials deposition system. A layer by layer 3D printing technique is deployed with an initial printing of source and drain by silver nanoparticle ink. Then graphene active layer doped with molybdenum disulfide (MoS2) monolayer/multilayer dispersion, is printed onto the surface of substrate covering the source and drain electrodes. High capacitance ion gel is adopted as the dielectric material due to the high dielectric constant. Then the dielectric layer is then covered with silver nanoparticle gate electrode. Characterization of GFET has been done at room temperature (25°C) using HP-4145B semiconductor parameter analyzer (Hewlett-Packard). The characterization result shows for a voltage sweep from -2 volts to 2 volts, the drain current changes from 949 nA to 32.3 μA and the GFET achieved an on/off ratio of 38:1, which is a milestone for inkjet printed flexible graphene transistor.

  18. The fabrication of carbon nanotube field-effect transistors with semiconductors as the source and drain contact materials.

    PubMed

    Xiao, Z; Camino, F E

    2009-04-01

    Sb(2)Te(3) and Bi(2)Te(2)Se semiconductor materials were used as the source and drain contact materials in the fabrication of carbon nanotube field-effect transistors (CNTFETs). Ultra-purified single-walled carbon nanotubes (SWCNTs) were ultrasonically dispersed in N-methyl pyrrolidone solvent. Dielectrophoresis was used to deposit and align SWCNTs for fabrication of CNTFETs. The Sb(2)Te(3)- and Bi(2)Te(2)Se-based CNTFETs demonstrate p-type metal-oxide-silicon-like I-V curves with high on/off drain-source current ratio at large drain-source voltages and good saturation of drain-source current with increasing drain-source voltage. The fabrication process developed is novel and has general meaning, and could be used for the fabrication of SWCNT-based integrated devices and systems with semiconductor contact materials.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  20. Dual drain MOSFET detector for crosstie memory systems

    NASA Astrophysics Data System (ADS)

    Bluzer, N.

    1985-03-01

    This patent application, which discloses a circuit for detecting binary information in crosstie memory systems includes a dual drain MOSFET device having a single channel with a common source and an integrated, thin-film strip of magnetic material suitable for the storage and propagation of Bloch line-crosstie pairs acting as both a shift register and the device's gate. Current flowing through the device, in the absence of a magnetic field, is equally distributed to each drain; however, changing magnetic fields, normal to the plane of the device and generated by Bloch line-crosstie pairs in the strip, interact with the current such that a distribution imbalance exists and one drain or the other receives a disproportionate fraction of the current depending upon the direction of the magnetic field.

  1. State of science of phosphorus modeling in tile drained agricultural systems using APEX

    USDA-ARS?s Scientific Manuscript database

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  2. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study.

    PubMed

    Kumar, Barun; Bhate, Kalyani; Dolas, R S; Kumar, Sn Santhosh; Waknis, Pushkar

    2016-12-01

    Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus.

  3. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    PubMed Central

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001), but the trend of pain score between groups was not significantly different (P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group (P < 0.05). Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF. PMID:29387121

  4. Optimization of limestone drains for long- term treatment of acidic mine drainage, Swatara Creek Basin, Schuylkill County, PA

    USGS Publications Warehouse

    Cravotta, Charles A.; Ward, S.J.; Koury, Daniel J.; Koch, R.D.

    2004-01-01

    Limestone drains were constructed in 1995, 1997, and 2000 to treat acidic mine drainage (AMD) from the Orchard, Buck Mtn., and Hegins discharges, respectively, in the Swatara Creek Basin, Southern Anthracite Coalfield, east-central Pennsylvania. This report summarizes the construction characteristics and performance of each of the limestone drains on the basis of influent and effluent quality and laboratory tests of variables affecting limestone dissolution rates. Data for influent and effluent indicate substantial alkalinity production by the Orchard and Buck Mtn. limestone drains and only marginal benefits from the Hegins drain. Nevertheless, the annual alkalinity loading rates have progressively declined with age of all three systems. Collapsible-container (cubitainer) testing was conducted to evaluate current scenarios and possible options for reconstruction and maintenance of the limestone drains to optimize their long-term performance. The cubitainer tests indicated dissolution rates for the current configurations that were in agreement with field flux data (net loading) for alkalinity and dissolved calcium. The dissolution rates in cubitainers were larger for closed conditions than open conditions, but the rates were comparable for coated and uncoated limestone for a given condition. Models developed on the basis of the cubitainer testing indicate (1) exponential declines in limestone mass and corresponding alkalinity loading rates with increased age of limestone drains and (2) potential for improved performance with enlargement, complete burial, and/or regular flushing of the systems.

  5. Nitrate and phosphorus transport through subsurface drains under free and controlled drainage.

    PubMed

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-05-28

    Controlled drainage (CD) is a structural conservation practice in which the drainage outlet is managed in order to reduce drain flow volume and nutrient loads to water bodies. The goal of this study was to evaluate the potential of CD to improve water quality for two different seasons and levels of outlet control, using ten years of data collected from an agricultural drained field in eastern Indiana with two sets of paired plots. The Rank Sum test was used to quantify the impact of CD on cumulative annual drain flow and nitrate-N and phosphorus loads. CD plots had a statistically significant (at 5% level) lower annual drain flow (eastern pair: 39%; western pair: 25%) and nitrate load (eastern pair: 43%; western pair: 26%) compared to free draining (FD) plots, while annual soluble reactive phosphorus (SRP) and total phosphorus (TP) loads were not significantly different. An ANCOVA model was used to evaluate the impact of CD on daily drain flow, nitrate-N, SRP and TP concentrations and loads during the two different periods of control. The average percent reduction of daily drain flow was 68% in the eastern pair and 58% in the western pair during controlled drainage at the higher outlet level (winter) and 64% and 58% at the lower outlet level (summer) in the eastern and western pairs, respectively. Nitrate load reduction was similar to drain flow reduction, while the effect of CD on SRP and TP loads was not significant except for the increase in SRP in one pair. These results from a decade-long field monitoring and two different statistical methods enhance our knowledge about water quality impacts of CD system and support this management practice as a reliable system for reducing nitrate loss through subsurface drains, mainly caused by flow reduction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Design Issues Affecting Pipings Associated with a New Moisture Separator Reheater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hyung-Keun, Kim; Jae-Kyoung, Cho

    2006-07-01

    This paper summarizes the piping design effects on a New Moisture Separator Reheater (MSR) in Shin-Kori Nuclear Power Plant Units 1 and 2 (SKN 1 and 2) being under the construction in Korea. This SKN 1 and 2 has the same arrangement of a Turbine-Generator set as one of Korea Standard Nuclear Plant Units ( OPR 1000 ) in commercial operation. The Turbine-Generator Supplier has developed a new Moisture Separator Reheater which has first and second stage heating steam supply connections respectively, at both ends of the shell side of the vessel in comparison to MSR of OPR 1000 whichmore » has first and second stage heating steam supply connections at only one end. The different locations of reheaters in MSR cause changes in the associated pipings such as 2. stage reheater heating steam, 2. stage reheater drain, shell drain, drain tank location and tank condensate drainage pipings. (authors)« less

  7. Navigating the socio-bio-geo-chemistry and engineering of nitrogen management in two illinois tile-drained watersheds.

    PubMed

    David, Mark B; Flint, Courtney G; Gentry, Lowell E; Dolan, Mallory K; Czapar, George F; Cooke, Richard A; Lavaire, Tito

    2015-03-01

    Reducing nitrate loads from corn and soybean, tile-drained, agricultural production systems in the Upper Mississippi River basin is a major challenge that has not been met. We evaluated a range of possible management practices from biophysical and social science perspectives that could reduce nitrate losses from tile-drained fields in the Upper Salt Fork and Embarras River watersheds of east-central Illinois. Long-term water quality monitoring on these watersheds showed that nitrate losses averaged 30.6 and 23.0 kg nitrate N ha yr (Embarras and Upper Salt Fork watersheds, respectively), with maximum nitrate concentrations between 14 and 18 mg N L. With a series of on-farm studies, we conducted tile monitoring to evaluate several possible nitrate reduction conservation practices. Fertilizer timing and cover crops reduced nitrate losses (30% reduction in a year with large nitrate losses), whereas drainage water management on one tile system demonstrated the problems with possible retrofit designs (water flowed laterally from the drainage water management tile to the free drainage system nearby). Tile woodchip bioreactors had good nitrate removal in 2012 (80% nitrate reduction), and wetlands had previously been shown to remove nitrate (45% reductions) in the Embarras watershed. Interviews and surveys indicated strong environmental concern and stewardship ethics among landowners and farmers, but the many financial and operational constraints that they operate under limited their willingness to adopt conservation practices that targeted nitrate reduction. Under the policy and production systems currently in place, large-scale reductions in nitrate losses from watersheds such as these in east-central Illinois will be difficult. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  8. Closure Report for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2012-08-15

    This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 562, Waste Systems, and provides documentation supporting the completed corrective actions and confirmation that closure objectives for CAU 562 were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 as amended). CAU 562 consists of the following 13 Corrective Action Sites (CASs), located in Areas 2, 23, and 25 of the Nevadamore » National Security Site: · CAS 02-26-11, Lead Shot · CAS 02-44-02, Paint Spills and French Drain · CAS 02-59-01, Septic System · CAS 02-60-01, Concrete Drain · CAS 02-60-02, French Drain · CAS 02-60-03, Steam Cleaning Drain · CAS 02-60-04, French Drain · CAS 02-60-05, French Drain · CAS 02-60-06, French Drain · CAS 02-60-07, French Drain · CAS 23-60-01, Mud Trap Drain and Outfall · CAS 23-99-06, Grease Trap · CAS 25-60-04, Building 3123 Outfalls Closure activities began in October 2011 and were completed in April 2012. Activities were conducted according to the Corrective Action Plan for CAU 562 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2011). The corrective actions included No Further Action and Clean Closure. Closure activities generated sanitary waste and hazardous waste. Some wastes exceeded land disposal limits and required offsite treatment prior to disposal. Other wastes met land disposal restrictions and were disposed in appropriate onsite or offsite landfills. NNSA/NSO requests the following: · A Notice of Completion from the Nevada Division of Environmental Protection to NNSA/NSO for closure of CAU 562 · The transfer of CAU 562 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO« less

  9. Phytoplankton abundance and structure as indicator of water quality in the drainage system of the Burullus Lagoon, southern Mediterranean coast, Egypt.

    PubMed

    El-Kassas, Hala Yassin; Gharib, Samiha Mahmoud

    2016-09-01

    This study represents the first detailed account of phytoplankton community structure and seasonal succession in eight drain sites and the Brimbal Canal influx into the Burullus Lagoon. The phytoplankton characteristics were studied based on the data collected seasonally over 4 years, from summer 2012 to spring 2016. Various indices such as Palmer's and Shannon's biotic indices were used for the assessment of the water quality of the different drains. There were a total of 194 species belonging to 65 genera and 6 groups: Bacillariophyceae (76 species), Chlorophyceae (59 species), Cyanophyceae (30 species), Euglenophyceae (25 species), Dinophyceae (3 species), and Xanthophyceae (1 species). The phytoplankton community was dominated with diatoms, green algae, and euglenoids such as Cyclotella, Scenedesmus, Navicula, Nitzschia, Ankistrodesmus, Chlorella, and Euglena. Maximum and minimum phytoplankton abundance was recorded at the Brimbal Canal and Hooks Drain. Maximum and minimum species diversities (H') were found at the Hooks Drain (2.564) and Burullus Drain (2.055). Species evenness fluctuated between 0.595 (Burullus Drain) and 0.750 (West Burullus Drain). The total score of algal genus pollution index and the algal species pollution index at the different drains showed that Drain 7 and the West Burullus Drain had moderate pollution, and the total score of the other drains were greater than 20 indicating the confirmed high organic pollution. Thus, the present investigation can be considered an attempt to use the phytoplankton community as a bioindicator of organic pollution.

  10. Concentrations and loads of suspended sediment and nutrients in surface water of the Yakima River basin, Washington, 1999-2000 [electronic resource] : with an analysis of trends in concentrations

    USGS Publications Warehouse

    Ebbert, James C.; Embrey, Sandra S.; Kelley, Janet A.

    2003-01-01

    Spatial and temporal variations in concentrations and loads of suspended sediment and nutrients in surface water of the Yakima River Basin were assessed using data collected during 1999?2000 as part of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program. Samples were collected at 34 sites located throughout the Basin in August 1999 using a Lagrangian sampling design, and also were collected weekly and monthly from May 1999 through January 2000 at three of the sites. Nutrient and sediment data collected at various time intervals from 1973 through 2001 by the USGS, Bureau of Reclamation, Washington State Department of Ecology, and Roza-Sunnyside Board of Joint Control were used to assess trends in concentrations. During irrigation season (mid-March to mid-October), concentrations of suspended sediment and nutrients in the Yakima River increase as relatively pristine water from the forested headwaters moves downstream and mixes with discharges from streams, agricultural drains, and wastewater treatment plants. Concentrations of nutrients also depend partly on the proportions of mixing between river water and discharges: in years of ample water supply in headwater reservoirs, more water is released during irrigation season and there is more dilution of nutrients discharged to the river downstream. For example, streamflow from river mile (RM) 103.7 to RM 72 in August 1999 exceeded streamflow in July 1988 by a factor of almost 2.5, but loads of total nitrogen and phosphorus discharged to the reach from streams, drains, and wastewater treatment plants were only 1.2 and 1.1 times larger. In years of ample water supply, canal water, which is diverted from either the Yakima or Naches River, makes up more of the flow in drains and streams carrying agricultural return flows. The canal water dilutes nutrients (especially nitrate) transported to the drains and streams in runoff from fields and in discharges from subsurface field drains and the shallow ground-water system. The average concentration of total nitrogen in drains and streams discharging to the Yakima River from RM 103.7 to RM 72 in August 1999 was 2.63 mg/L, and in July 1988 was 3.16 mg/L; average concentrations of total phosphorus were 0.20 and 0.26 mg/L. After irrigation season, streamflow in agricultural drains decreases because irrigation water is no longer diverted from the Yakima and Naches Rivers. As a result, concentrations of total nitrogen in drains increase because nitrate, which constitutes much of total nitrogen, continues to enter the drains from subsurface drains and shallow ground water. Concentrations of total phosphorus and suspended sediment often decrease, because they are transported to the drains in runoff of irrigation water from fields. In Granger Drain, concentrations of total nitrogen ranged from 2-4 mg/L during irrigation season and increased to about 6 mg/L after irrigation season, and concentrations of total phosphorus, as high as 1 mg/L, decreased to about 0.2 mg/L. In calendar year 1999, Moxee Drain transported an average of 28,000 lb/d (pounds per day) of suspended sediment, 380 lb/d of total nitrogen, and 46 lb/d of total phosphorus to the Yakima River. These loads were about half the average loads transported by Granger Drain during the same period. Average streamflows were similar for the two drains, so the difference in loads was due to differences in constituent concentrations: those in Moxee Drain were about 40-60 percent less than those in Granger Drain. Loads of suspended sediment and total phosphorus in Moxee and Granger Drains were nearly four times higher during irrigation season than during the non-irrigation season because with increased flow during irrigation season, concentrations of suspended sediment and total phosphorus are usually higher. Loads of nitrate in the drains were about the same in both seasons because nitrate concentrations are higher during the non-irrigation season.

  11. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    PubMed

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  12. Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

  13. Randomised clinical trial of chest drainage systems.

    PubMed Central

    Graham, A N; Cosgrove, A P; Gibbons, J R; McGuigan, J A

    1992-01-01

    BACKGROUND: Problems in the management of thoracic trauma have stimulated the search for an alternative to underwater seals for drainage of the pleural cavity. A chest drainage bag incorporating a one way flutter valve has been compared with underwater seal drains in a randomised clinical trial. METHODS: During June-December 1989 119 patients undergoing elective thoracotomy were randomised to receive postoperative chest drainage by drainage bags (56 patients, 87 drains) or by underwater seal drains (63 patients, 98 drains). Daily drainage volumes, the requirement for pleural suction, mobility, and complications were recorded prospectively. RESULTS: There was no significant difference between the two groups in the mean volume drained, the requirements for pleural suction, or the occurrence of complications. Patients with drainage bags were fully mobile 23 hours (95% confidence interval 0-47 hours) earlier than the others. CONCLUSIONS: When used after elective thoracotomy drainage bags are safe and effective and permit earlier mobility than underwater seal drains. PMID:1496507

  14. Ensemble Monte Carlo particle investigation of hot electron induced source-drain burnout characteristics of GaAs field-effect transistors

    NASA Astrophysics Data System (ADS)

    Moglestue, C.; Buot, F. A.; Anderson, W. T.

    1995-08-01

    The lattice heating rate has been calculated for GaAs field-effect transistors of different source-drain channel design by means of the ensemble Monte Carlo particle model. Transport of carriers in the substrate and the presence of free surface charges are also included in our simulation. The actual heat generation was obtained by accounting for the energy exchanged with the lattice of the semiconductor during phonon scattering. It was found that the maximum heating rate takes place below the surface near the drain end of the gate. The results correlate well with a previous hydrodynamic energy transport estimate of the electronic energy density, but shifted slightly more towards the drain. These results further emphasize the adverse effects of hot electrons on the Ohmic contacts.

  15. Regenerative switching CMOS system

    DOEpatents

    Welch, James D.

    1998-01-01

    Complementary Metal Oxide Semiconductor (CMOS) Schottky barrier Field Effect Transistor systems, which are a seriesed combination of N and P-Channel MOSFETS, in which Source Schottky barrier junctions of the N and P-Channel Schottky barrier MOSFETS are electically interconnected, (rather than the Drains as in conventional diffused junction CMOS), which Schottky barrier MOSFET system demonstrates Regenerative Inverting Switching Characteristics in use are disclosed. Both the N and P-Channel Schottky barrier MOSFET devices are unique in that they provide operational Drain Current vs. Drain to Source voltage as a function of Gate voltage only where the polarities of the Drain voltage and Gate voltage are opposite, referenced to the Source as a common terminal, and where the polarity of the voltage applied to the Gate is appropriate to cause Channel inversion. Experimentally derived results which demonstrate and verify the operation of N and P-Channel Schottky barrier MOSFETS actually fabricated on P and N-type Silicon respectively, by a common procedure using vacuum deposited Chromium as a Schottky barrier forming metal, are also provided.

  16. Regenerative switching CMOS system

    DOEpatents

    Welch, J.D.

    1998-06-02

    Complementary Metal Oxide Semiconductor (CMOS) Schottky barrier Field Effect Transistor systems, which are a series combination of N and P-Channel MOSFETS, in which Source Schottky barrier junctions of the N and P-Channel Schottky barrier MOSFETS are electrically interconnected, (rather than the Drains as in conventional diffused junction CMOS), which Schottky barrier MOSFET system demonstrates Regenerative Inverting Switching Characteristics in use are disclosed. Both the N and P-Channel Schottky barrier MOSFET devices are unique in that they provide operational Drain Current vs. Drain to Source voltage as a function of Gate voltage only where the polarities of the Drain voltage and Gate voltage are opposite, referenced to the Source as a common terminal, and where the polarity of the voltage applied to the Gate is appropriate to cause Channel inversion. Experimentally derived results which demonstrate and verify the operation of N and P-Channel Schottky barrier MOSFETS actually fabricated on P and N-type Silicon respectively, by a common procedure using vacuum deposited Chromium as a Schottky barrier forming metal, are also provided. 14 figs.

  17. 37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING SYSTEM. NOTE SPIGOT UNDER BOARD AT UPPER LEFT INSERTS INTO HOLE IN PIPE AT BOTTOM OF FRAME. CYANIDE SOLUTION WAS PUMPED INTO THE TANKS AND THE PREGNANT SOLUTION DRAINED OUT OF THE TANKS THROUGH THIS PIPE, AND BACK INTO A SEPARATE HOLDING TANK ON THE EAST SIDE OF THE MILL. TAILINGS WERE REMOVED FROM THE TANKS THROUGH THE ROUND DRAIN DOOR IN THE BOTTOM OF THE TANK (MISSING) SEEN AT TOP CENTER. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA

  18. The effect of asymmetrical electrode form after negative bias illuminated stress in amorphous IGZO thin film transistors

    NASA Astrophysics Data System (ADS)

    Su, Wan-Ching; Chang, Ting-Chang; Liao, Po-Yung; Chen, Yu-Jia; Chen, Bo-Wei; Hsieh, Tien-Yu; Yang, Chung-I.; Huang, Yen-Yu; Chang, Hsi-Ming; Chiang, Shin-Chuan; Chang, Kuan-Chang; Tsai, Tsung-Ming

    2017-03-01

    This paper investigates the degradation behavior of InGaZnO thin film transistors (TFTs) under negative bias illumination stress (NBIS). TFT devices with two different source and drain layouts were exanimated: one having a parallel format electrode and the other with UI format electrode. UI means that source/drain electrodes shapes is defined as a forked-shaped structure. The I-V curve of the parallel electrode exhibited a symmetric degradation under forward and reverse sweeping in the saturation region after 1000 s NBIS. In contrast, the I-V curve of the UI electrode structure under similar conditions was asymmetric. The UI electrode structure also shows a stretch-out phenomenon in its C-V measurement. Finally, this work utilizes the ISE-Technology Computer Aided Design (ISE-TCAD) system simulations, which simulate the electron field and IV curves, to analyze the mechanisms dominating the parallel and UI device degradation behaviors.

  19. AmeriFlux CA-Qcu Quebec - Eastern Boreal, Black Spruce/Jack Pine Cutover

    DOE Data Explorer

    Margolis, Hank A. [Université Laval

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site CA-Qcu Quebec - Eastern Boreal, Black Spruce/Jack Pine Cutover. Site Description - The ground is gently rolling with a weak slope (<5%). In mesic areas (designated as well to moderately well drained areas, according to the Canadian System of Soil Classification (Agriculture Canada Expert Committee on Soil Survey, 1983)), the soil is a ferro-humic to humic podzol covered by an organic layer having an average depth of 26 cm (Fig. 1). In humid areas, the soil is organic (imperfectly to poorly drained) with an average organic layer of 125 cm. Mesic areas accounted for approximately 75% of the total surface area of the footprint and humid areas accounted for 25%. Full-time continuous measurements eneded in 2011. Intermittent measurements are on-going as resources permit.

  20. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study

    PubMed Central

    Bhate, Kalyani; Dolas, RS; Kumar, SN Santhosh; Waknis, Pushkar

    2016-01-01

    Introduction Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. Aim To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Materials and Methods Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. Results The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. Conclusion The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus. PMID:28209003

  1. Durability of Drainage Improvement by Combination of Main Drain and Trench Drains with Vertical Drains in Clayey Field Converted from Paddy to Upland Use

    NASA Astrophysics Data System (ADS)

    Adachi, Kazuhide; Ohno, Satoshi; Furuhata, Masami; Ogura, Chikara; Tanimoto, Takeshi

    The drainage efficiency of a subsurface drainage system for avoidance of standing water on the plow pan of clayey field was evaluated. A subsurface drainage system with a main drain and orthogonally adjoined rice husk trench drains joined by vertical rice husk drains was constructed on a test plot and compared to an identical control plot of paddy field converted to upland use under soybean cultivation. The ratio of total underdrain discharge to rainfall in the improved plot greatly increased over two years compared to that in a control plot. In the improved plot, the peak underdrain discharge per hour associated with some heavy rainfalls was around 3 mm/h in the first year but decreased to about 2 mm/h in the second year. By improving drainage in the paddy field, standing water on the plow pan was quickly eliminated after rain events and the period of flooding on the plow pan during the soybean growing season was greatly reduced. However, underdrain discharge in the improved plot decreased greatly in the third year to be at the same level as in the control plot, and rain water flooded the plow pan for extended periods of time.

  2. Restructuring brain drain: strengthening governance and financing for health worker migration.

    PubMed

    Mackey, Tim K; Liang, Bryan A

    2013-01-15

    Health worker migration from resource-poor countries to developed countries, also known as ''brain drain'', represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  3. 46 CFR 169.565 - Fixed carbon dioxide system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., protected against injury. (5) Drains and dirt traps must be fitted where necessary to prevent accumulation of dirt or moisture. Each drain and dirt trap must be located in accessible locations but not in...

  4. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  5. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  6. Alternative design of pipe sleeve for liquid removal mechanism in mortar slab layer

    NASA Astrophysics Data System (ADS)

    Nazri, W. M. H. Wan; Anting, N.; Lim, A. J. M. S.; Prasetijo, J.; Shahidan, S.; Din, M. F. Md; Anuar, M. A. Mohd

    2017-11-01

    Porosity is one of the mortar’s characteristics that can cause problems, especially in the room space that used high amount of water, such as bathrooms. Waterproofing is one of the technology that normally used to minimize this problem which is preventing deep penetration of liquid water or moisture into underlying concrete layers. However, without the proper mechanism to remove liquid water and moisture from mortar system, waterproofing layer tends to be damaged after a long period of time by the static formation of liquid water and moisture at mortar layer. Thus, a solution has been proposed to drain out water that penetrated into the mortar layer. This paper introduces a new solution using a Modified Pipe Sleeve (MPS) that installed at the mortar layer. The MPS has been designed considering the percentage surface area of the pipe sleeve that having contact with mortar layer (2%, 4%, 6%, 8% and 10%) with angle of holes of 60°. Infiltration test and flow rate test have been conducted to identify the effectiveness of the MPS in order to drain out liquid water or moisture from the mortar layer. In this study shows that, MPS surface area 10%, angled 60°, function effectively as a water removal compared to other design.

  7. Water balance of drained plantation watersheds in North Carolina

    Treesearch

    Johnny M. Grace; R. W. Skaggs

    2006-01-01

    A 3-year study to evaluate the effect of thinning on the hydrology of a drained loblolly pine (Pinus taeda L.) plantation was conducted in eastern North Carolina. The study utilized a paired watershed design with a 40-ha thinned watershed (WS5) and a 16-ha control watershed (WS2). Data from the field experiment conducted from 1999-2002 was used to...

  8. Design and Development of a Segmented Magnet Homopolar Torque Converter

    DTIC Science & Technology

    1975-07-01

    configuration Hydrostatically-positioned seal ( sealed drain) Hydrostatically-positioned seal Power- leakage relationship for a single annular seal lip... Seal 1. conducting wick - stationary/rotating, fiber, foam 2. hydrodynamic/hydrostatic 3. flooded (alternately) labyrinth C. Low-Speed Flooding...between collectors may be used to introduce oil droplets to lubricate the seals and to drain any NaK leakage that might occur Alternatively, they

  9. National Program for Inspection of Non-Federal Dams. Upper Eddy Pond Dam (VT 00231), Richelieu River Basin, Rutland, Vermont. Phase I Inspection Report.

    DTIC Science & Technology

    1981-04-01

    crest. There Is a pond drain about 18 inches in dimeter which is reported to be Inoperable. The top of dam stor-5 age is estimated to be 51 acre-fot...related to lateral movements and/or settlement of the rubbish fill. The dumped material should be removed and the embankment regraded. The seep- age area...drain- age area. 6 5.2 DESIGN DATA No hydraulic or hydrologic design data or criteria were available. 5.3 EXPERIENCE DATA There is no evidence of recent

  10. Decontamination systems information and research program. Quarterly report, April--June 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This report contains separate reports on the following subtasks: analysis of the Vortec cyclone melting system for remediation of PCB contaminated soils using CFD; drain enhanced soil flushing using prefabricated vertical drains; performance and characteristics evaluation of acrylates as grout barriers; development of standard test protocol barrier design models for desiccation barriers, and for in-situ formed barriers; in-situ bioremediation of chlorinated solvents at Portsmouth Gaseous Diffusion Plant; development of a decision support system and a prototype database for management of the EM50 technology development program; GIS-based infrastructure for site characterization and remediation; treatment of mixed wastes via fluidized bed steammore » reforming; use of centrifugal membrane technology to treat hazardous/radioactive waste; environmental pollution control devices based on novel forms of carbon; development of instrumental methods for analysis of nuclear wastes and environmental materials; production and testing of biosorbents and cleaning solutions for D and D; use of SpinTek centrifugal membrane and sorbents/cleaning solutions for D and D; West Virginia High Tech Consortium Foundation--Environmental support program; small business interaction opportunities; and approach for assessing potential voluntary environmental protection.« less

  11. 29 CFR 1910.126 - Additional requirements for special dipping and coating operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operations from fire, you must have in place: (i) Automatic sprinklers; or (ii) An automatic fire... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...

  12. 29 CFR 1910.126 - Additional requirements for special dipping and coating operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operations from fire, you must have in place: (i) Automatic sprinklers; or (ii) An automatic fire... the alarm set point, you must equip the tank with a circulating cooling system. (5) If the tank has a bottom drain, the bottom drain may be combined with the oil-circulating system. (6) You must not use air...

  13. Ecotoxicologic impacts of agricultural drain water in the Salinas River, California, USA.

    PubMed

    Anderson, Brian S; Hunt, John W; Phillips, Bryn M; Nicely, Patricia A; Gilbert, Kristine D; de Vlaming, Victor; Connor, Valerie; Richard, Nancy; Tjeerdema, Ronald S

    2003-10-01

    The Salinas River is the largest of the three rivers that drain into the Monterey Bay National Marine Sanctuary in central California (USA). Large areas of this watershed are cultivated year-round in row crops, and previous laboratory studies have demonstrated that acute toxicity of agricultural drain water to Ceriodaphnia dubia is caused by the organophosphate (OP) pesticides chlorpyrifos and diazinon. We investigated chemical contamination and toxicity in waters and sediments in the river downstream of an agricultural drain water input. Ecological impacts of drain water were investigated by using bioassessments of macroinvertebrate community structure. Toxicity identification evaluations were used to characterize chemicals responsible for toxicity. Salinas River water downstream of the agricultural drain was acutely toxic to the cladoceran Ceriodaphnia dubia, and toxicity to C. dubia was highly correlated with combined toxic units (TUs) of chlorpyrifos and diazinon. Laboratory tests were used to demonstrate that sediments in this system were acutely toxic to the amphipod Hyalella azteca, a resident invertebrate. Toxicity identification evaluations (TIEs) conducted on sediment pore water suggested that toxicity to amphipods was due in part to OP pesticides; concentrations of chlorpyrifos in pore water sometimes exceeded the 10-d mean lethal concentration (LC50) for H. azteca. Potentiation of toxicity with addition of the metabolic inhibitor piperonyl butoxide suggested that sediment toxicity also was due to other non-metabolically activated compounds. Macroinvertebrate community structure was highly impacted downstream of the agricultural drain input, and a number of macroinvertebrate community metrics were negatively correlated with combined TUs of chlorpyrifos and diazinon, as well as turbidity associated with the drain water. Some macroinvertebrate metrics were also correlated with bank vegetation cover. This study suggests that pesticide pollution is the likely cause of ecological damage in the Salinas River, and this factor may interact with other stressors associated with agricultural drain water to impact the macroinvertebrate community in the system.

  14. Method and system for reducing device performance degradation of organic devices

    DOEpatents

    Teague, Lucile C.

    2014-09-02

    Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.

  15. Effect of tube drainage compared with conventional suturing on postoperative discomfort after extraction of impacted mandibular third molars.

    PubMed

    Koyuncu, B Ö; Zeytinoğlu, M; Tetik, A; Gomel, M M

    2015-01-01

    The aim of this prospective randomised study was to assess the effects of tube drainage on postoperative discomfort after the extraction of impacted mandibular third molars. We studied 40 patients (11 men and 29 women) 18 years or older (mean (SD) 21 (3), range 18-29) who required extraction of mandibular third molars. We used a randomised crossover design by which if a drain was inserted on one side, then the other side was managed without a drain on a later occasion. Pain, swelling, and mouth opening were evaluated after 48 h and 7 days postoperatively in both groups. Facial swelling (p=0.001), pain p=0.001), and trismus (p=0.001) were significantly less common in the drained group compared with those not drained. We conclude that the use a tube drain is of benefit in minimising postoperative swelling, pain, and trismus after extraction of mandibular third molars. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Multitracer Study of Flow to Tile Drains in Irrigated Macroporous Soil

    NASA Astrophysics Data System (ADS)

    Bishop, J. M.; Callaghan, M. V.; Cey, E.; Bentley, L. R.

    2010-12-01

    Multiple tracer experiments have been conducted to test the effectiveness of using irrigation along with a tile drain system for salt remediation in west central Alberta, Canada. The experiments were designed to characterize the shallow flow system as part of a salt flushing pilot study and to determine the role of macroporosity in groundwater flow and transport. Soils at the site are primarily silty glaciolacustrine material underlain by a relatively impermeable till layer at approximately 2.5 m below ground surface. A 20 m by 20 m infiltration test plot is underlain by two tile drains at 2 m depth that are separated by 10 m. The test plot contains a drip irrigation system and has been irrigated regularly in the summer months over the past three seasons (2008-2010). Two reportedly conservative tracers, 2,6-difluorobenzoic acid [2,6-DFBA] and pentafluorobenzoic acid [PFBA], have been used on the plot and the pre-existing soil salinity was also used as a tracer. In August of 2009 a 2,6-DFBA solution (865g/L) was applied to the surface of the plot. Irrigation of the study plot continued after tracer application on a schedule that averaged roughly 12mm/day, applied 3 days a week. During the 2010 field season, a PFBA solution (at 4.2 g/L) was injected into two separate monitoring wells. One monitoring well is situated 0.5 m directly above the north tile drain (in which samples were collected regularly). The other well is situated at 2 m depth in the center of the study plot and samples were collected from a down gradient well. Tracer concentrations in the subsurface were monitored through sampling of tile drain effluent and monitoring wells in and around the plot, in addition to soil core extractions taken at several locations within the test plot at the end of the 2009 field season. Initial breakthrough of the DFBA in the tile drains occurred 24 hours after application and remained in all subsequent water samples at concentrations of 2 to 6 mg/L. Results from the DFBA analysis showed that the tiles are highly affected by the lateral and vertical contributions to the drains. Distribution of the DFBA in the soil showed that 82% of the tracer remained in the top 75 cm of the soil profile at the end of the 2009 season. This indicates that macropore flow is occurring, but has a minor influence on the movement of the salt mass. This result is important because it illustrates that although the salt mass has migrated slowly, macroporosity can transport contaminants quickly enough to exceeded drinking water quality guidelines. Breakthrough of the PFBA occurred in the north tile drain 13 hrs after application and peaked at a concentration of 10 mg/L, followed by a sharp decrease and stabilization to concentrations of 1.0 mg/L. This shows that macropore flow is occurring at depth in addition to the surface and that contaminant transport can occur rapidly in soils with lower hydraulic conductivity. Salt concentrations in the effluent were measured at high concentrations, showing that effective salt flushing of the matrix is still occurring.

  17. Modeling and simulation of enhancement mode p-GaN Gate AlGaN/GaN HEMT for RF circuit switch applications

    NASA Astrophysics Data System (ADS)

    Panda, D. K.; Lenka, T. R.

    2017-06-01

    An enhancement mode p-GaN gate AlGaN/GaN HEMT is proposed and a physics based virtual source charge model with Landauer approach for electron transport has been developed using Verilog-A and simulated using Cadence Spectre, in order to predict device characteristics such as threshold voltage, drain current and gate capacitance. The drain current model incorporates important physical effects such as velocity saturation, short channel effects like DIBL (drain induced barrier lowering), channel length modulation (CLM), and mobility degradation due to self-heating. The predicted I d-V ds, I d-V gs, and C-V characteristics show an excellent agreement with the experimental data for both drain current and capacitance which validate the model. The developed model was then utilized to design and simulate a single-pole single-throw (SPST) RF switch.

  18. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    PubMed

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  19. X-34 Main Propulsion System Design and Operation

    NASA Technical Reports Server (NTRS)

    Champion, R. J., Jr.; Darrow, R. J., Jr.

    1998-01-01

    The X-34 program is a joint industry/government program to develop, test, and operate a small, fully-reusable hypersonic flight vehicle, utilizing technologies and operating concepts applicable to future Reusable Launch Vehicle (RLV) systems. The vehicle will be capable of Mach 8 flight to 250,000 feet altitude and will demonstrate an all composite structure, composite RP-1 tank, the Marshall Space Flight Center (MSFC) developed Fastrac engine, and the operability of an advanced thermal protection systems. The vehicle will also be capable of carrying flight experiments. MSFC is supporting the X-34 program in three ways: Program Management, the Fastrac engine as Government Furnished Equipment (GFE), and the design of the Main Propulsion System (MPS). The MPS Product Development Team (PDT) at MSFC is responsible for supplying the MPS design, analysis, and drawings to Orbital. The MPS consists of the LOX and RP-1 Fill, Drain, Feed, Vent, & Dump systems and the Helium & Nitrogen Purge, Pressurization, and Pneumatics systems. The Reaction Control System (RCS) design was done by Orbital. Orbital is the prime contractor and has responsibility for integration, procurement, and construction of all subsystems. The paper also discusses the design, operation, management, requirements, trades studies, schedule, and lessons learning with the MPS and RCS designs.

  20. Analytical solutions for flow fields near drain-and-gate reactive barriers.

    PubMed

    Klammler, Harald; Hatfield, Kirk; Kacimov, Anvar

    2010-01-01

    Permeable reactive barriers (PRBs) are a popular technology for passive contaminant remediation in aquifers through installation of reactive materials in the pathway of a plume. Of fundamental importance are the degree of remediation inside the reactor (residence time) and the portion of groundwater intercepted by a PRB (capture width). Based on a two-dimensional conformal mapping approach (previously used in related work), the latter is studied in the present work for drain-and-gate (DG) PRBs, which may possess a collector and a distributor drain ("full" configuration) or a collector drain only ("simple" configuration). Inherent assumptions are a homogeneous unbounded aquifer with a uniform far field, in which highly permeable drains establish constant head boundaries. Solutions for aquifer flow fields in terms of the complex potential are derived, illustrated, and analyzed for doubly symmetric DG configurations and arbitrary reactor hydraulic resistance as well as ambient groundwater flow direction. A series of practitioner-friendly charts for capture width is given to assist in PRB design and optimization without requiring complex mathematics. DG PRBs are identified as more susceptible to flow divergence around the reactor than configurations using impermeable side structures (e.g., funnel-and-gate), and deployment of impermeable walls on drains is seen to mitigate this problem under certain circumstances.

  1. Evidence-based Value of Prophylactic Drainage in Gastrointestinal Surgery

    PubMed Central

    Petrowsky, Henrik; Demartines, Nicolas; Rousson, Valentin; Clavien, Pierre-Alain

    2004-01-01

    Objective: To determine the evidence-based value of prophylactic drainage in gastrointestinal (GI) surgery. Methods: An electronic search of the Medline database from 1966 to 2004 was performed to identify articles comparing prophylactic drainage with no drainage in GI surgery. The studies were reviewed and classified according to their quality of evidence using the grading system proposed by the Oxford Centre for Evidence-based Medicine. Seventeen randomized controlled trials (RCTs) were found for hepato-pancreatico-biliary surgery, none for upper GI tract, and 13 for lower GI tract surgery. If sufficient RCTs were identified, we performed a meta-analysis to characterize the drain effect using the random-effects model. Results: There is evidence of level 1a that drains do not reduce complications after hepatic, colonic, or rectal resection with primary anastomosis and appendectomy for any stage of appendicitis. Drains were even harmful after hepatic resection in chronic liver disease and appendectomy. In the absence of RCTs, there is a consensus (evidence level 5) about the necessity of prophylactic drainage after esophageal resection and total gastrectomy due to the potential fatal outcome in case of anastomotic and gastric leakage. Conclusion: Many GI operations can be performed safely without prophylactic drainage. Drains should be omitted after hepatic, colonic, or rectal resection with primary anastomosis and appendectomy for any stage of appendicitis (recommendation grade A), whereas prophylactic drainage remains indicated after esophageal resection and total gastrectomy (recommendation grade D). For many other GI procedures, especially involving the upper GI tract, there is a further demand for well-designed RCTs to clarify the value of prophylactic drainage. PMID:15570212

  2. Solar heating system installed at Blakedale Professional Center, Greenwood, South Carolina

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Information on the solar heating system installed at the Blakedale Professional Center, in Greenwood, South Carolina is presented. The information consists of site and building description, solar system description, performance evaluation, system problems and installation drawings. The solar system was designed to provide approximately 85 percent of the building's heating requirements. The system was installed concurrently with building construction and heats 4,440 square feet of the building. There are 954 square feet of liquid flat plate collectors that are proof-mounted and have a drain-down system to protect the collectors from freezing. A 5,000 gallon steel, polyurethane insulated tank buried underground provides storage. The system was fully instrumented for performance evaluation and integrated into the National Solar Data Network.

  3. Developing an evidence-based nursing protocol on wound drain management for total joint arthroplasty.

    PubMed

    Tsang, Lap Fung

    2015-05-01

    Although various drains have long been used for many years in total joint replacement, there is a paucity of evidence for the benefit of drain applications. Evidence suggests inconsistent practice in the use of drainage systems, whether intermittently applying suction or free of suction in the application of drainage systems, as well as the optimal timing for wound drain removal. It aimed to perform a systematic review to develop an evidence-based nursing protocol to manage wound drainage following total joint arthroplasty. A comprehensive systematic review of available evidence up to 2013. Searches of the EMBASE, Cochrane library, CINAHL, Medline electronic databases and an internet search by Yahoo and Google engine returned 2840 records, of which 11 met the inclusion criteria for this review. A further two papers were obtained through scanning the reference lists of those articles included from the initial literature search. Different clamping times were retrieved from the literature. A protocol was adapted for clinical application according to the summary of the retrieved information. It is suggested that clamping is performed 1 h after the insertion of suction drains post-operatively in the operating theatre. Wound drains should be clamped for 1 h if blood loss is more than 600 ml in 6 h in first 24 h. Wound drains should be clamped for 1 h if blood loss is more than 800 ml in 8 h thereafter. It is suggested that the drainage reservoir bottle should be mark and findings recorded in line with the principle of drain clamping. This means that the amount of drainage is measured and recorded every 6 h in first 24 h and every 8 h thereafter. It is suggested that wound drains should be remove before 48 h after TJR. If blood loss is less than 50 ml in past 6 h or less than 70 ml in past 8 h, the drain should be remove and the wound site should be monitored closely. This paper has guided nurses to develop an evidence-based protocol to improve patient care on wound drain management. Further study is necessary to evaluate the effectiveness of the protocol. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Building pit dewatering: application of transient analytic elements.

    PubMed

    Zaadnoordijk, Willem J

    2006-01-01

    Analytic elements are well suited for the design of building pit dewatering. Wells and drains can be modeled accurately by analytic elements, both nearby to determine the pumping level and at some distance to verify the targeted drawdown at the building site and to estimate the consequences in the vicinity. The ability to shift locations of wells or drains easily makes the design process very flexible. The temporary pumping has transient effects, for which transient analytic elements may be used. This is illustrated using the free, open-source, object-oriented analytic element simulator Tim(SL) for the design of a building pit dewatering near a canal. Steady calculations are complemented with transient calculations. Finally, the bandwidths of the results are estimated using linear variance analysis.

  5. Effect of electrode design on crosstalk between neighboring organic field-effect transistors based on one single crystal

    NASA Astrophysics Data System (ADS)

    Li, Mengjie; Tang, Qingxin; Tong, Yanhong; Zhao, Xiaoli; Zhou, Shujun; Liu, Yichun

    2018-03-01

    The design of high-integration organic circuits must be such that the interference between neighboring devices is eliminated. Here, rubrene crystals were used to study the effect of the electrode design on crosstalk between neighboring organic field-effect transistors (OFETs). Results show that a decreased source/drain interval and gate electrode width can decrease the diffraction distance of the current, and therefore can weaken the crosstalk. In addition, the inherent low carrier concentration in organic semiconductors can create a high-resistance barrier at the space between gate electrodes of neighboring devices, limiting or even eliminating the crosstalk as a result of the gate electrode width being smaller than the source/drain electrode width.

  6. Schottky barrier MOSFET systems and fabrication thereof

    DOEpatents

    Welch, James D.

    1997-01-01

    (MOS) device systems-utilizing Schottky barrier source and drain to channel region junctions are disclosed. Experimentally derived results which demonstrate operation of fabricated N-channel and P-channel Schottky barrier (MOSFET) devices, and of fabricated single devices with operational characteristics similar to (CMOS) and to a non-latching (SRC) are reported. Use of essentially non-rectifying Schottky barriers in (MOS) structures involving highly doped and the like and intrinsic semiconductor to allow non-rectifying interconnection of, and electrical accessing of device regions is also disclosed. Insulator effected low leakage current device geometries and fabrication procedures therefore are taught. Selective electrical interconnection of drain to drain, source to drain, or source to source, of N-channel and/or P-channel Schottky barrier (MOSFET) devices formed on P-type, N-type and Intrinsic semiconductor allows realization of Schottky Barrier (CMOS), (MOSFET) with (MOSFET) load, balanced differential (MOSFET) device systems and inverting and non-inverting single devices with operating characteristics similar to (CMOS), which devices can be utilized in modulation, as well as in voltage controled switching and effecting a direction of rectification.

  7. Schottky barrier MOSFET systems and fabrication thereof

    DOEpatents

    Welch, J.D.

    1997-09-02

    (MOS) device systems-utilizing Schottky barrier source and drain to channel region junctions are disclosed. Experimentally derived results which demonstrate operation of fabricated N-channel and P-channel Schottky barrier (MOSFET) devices, and of fabricated single devices with operational characteristics similar to (CMOS) and to a non-latching (SRC) are reported. Use of essentially non-rectifying Schottky barriers in (MOS) structures involving highly doped and the like and intrinsic semiconductor to allow non-rectifying interconnection of, and electrical accessing of device regions is also disclosed. Insulator effected low leakage current device geometries and fabrication procedures therefore are taught. Selective electrical interconnection of drain to drain, source to drain, or source to source, of N-channel and/or P-channel Schottky barrier (MOSFET) devices formed on P-type, N-type and Intrinsic semiconductor allows realization of Schottky Barrier (CMOS), (MOSFET) with (MOSFET) load, balanced differential (MOSFET) device systems and inverting and non-inverting single devices with operating characteristics similar to (CMOS), which devices can be utilized in modulation, as well as in voltage controlled switching and effecting a direction of rectification. 89 figs.

  8. A terrain-based paired-site sampling design to assess biodiversity losses from eastern hemlock decline

    USGS Publications Warehouse

    Young, J.A.; Smith, D.R.; Snyder, C.D.; Lemarie, D.P.

    2002-01-01

    Biodiversity surveys are often hampered by the inability to control extraneous sources of variability introduced into comparisons of populations across a heterogenous landscape. If not specifically accounted for a priori, this noise can weaken comparisons between sites, and can make it difficult to draw inferences about specific ecological processes. We developed a terrain-based, paired-site sampling design to analyze differences in aquatic biodiversity between streams draining eastern hemlock (Tsuga canadensis) forests, and those draining mixed hardwood forests in Delaware Water Gap National Recreation Area (USA). The goal of this design was to minimize variance due to terrain influences on stream communities, while representing the range of hemlock dominated stream environments present in the park. We used geographic information systems (GIS) and cluster analysis to define and partition hemlock dominated streams into terrain types based on topographic variables and stream order. We computed similarity of forest stands within terrain types and used this information to pair hemlock-dominated streams with hardwood counterparts prior to sampling. We evaluated the effectiveness of the design through power analysis and found that power to detect differences in aquatic invertebrate taxa richness was highest when sites were paired and terrain type was included as a factor in the analysis. Precision of the estimated difference in mean richness was nearly doubled using the terrain-based, paired site design in comparison to other evaluated designs. Use of this method allowed us to sample stream communities representative of park-wide forest conditions while effectively controlling for landscape variability.

  9. Two-dimensional analytical model for dual-material control-gate tunnel FETs

    NASA Astrophysics Data System (ADS)

    Xu, Hui Fang; Dai, Yue Hua; Gui Guan, Bang; Zhang, Yong Feng

    2016-09-01

    An analytical model for a dual-material control-gate (DMCG) tunnel field effect transistor (TFET) is presented for the first time in this paper, and the influence of the mobile charges on the potential profile is taken into account. On the basis of the potential profile, the lateral electric field is derived and the expression for the drain current is obtained by integrating the band-to-band tunneling (BTBT) generation rate applicable to low-bandgap and high-bandgap materials over the tunneling region. The model also predicts the impacts of the control-gate work function on the potential and drain current. The advantage of this work is that it not only offers physical insight into device physics but also provides the basic designing guideline for DMCG TFETs, enabling the designer to optimize the device in terms of the on-state current, the on-off current ratio, and suppressed ambipolar behavior. Very good agreements for both the potential and drain current are observed between the model calculations and the simulated results.

  10. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... restricts wind motion across the open area between the pipe and the drain) that encloses the space between...., there is no pump) or is operated with no more than slight fluctuations in the liquid level, the owner or...

  11. Drain placement can safely be omitted for open partial nephrectomy: Results from a prospective randomized trial.

    PubMed

    Kriegmair, Maximilian C; Mandel, Philipp; Krombach, Patrick; Dönmez, Hasan; John, Axel; Häcker, Axel; Michel, Maurice S

    2016-05-01

    To examine the benefit of drain placement during open partial nephrectomy. Overall, 106 patients treated with open partial nephrectomy were enrolled in a prospective randomized trial. Based on the randomization, a drain was placed or omitted. Complications were assessed according to the Clavien classification. Pain level and requirement for analgesics was evaluated according to a customized pattern. There was no significant difference in the two groups regarding age, body mass index, American Society of Anesthesiologists score, tumor size and nephrometry (preoperative aspects and dimensions used for an anatomical classification). In terms of overall and drain-related complications, no advantage of placing a drain could be proven (P = 0.249). Patients with a drain suffered from a significantly higher pain level (P = 0.01) and showed prolonged mobilization (P < 0.001). There was no difference in bowel movements and requirement of additional analgesics (P = 0.347 and 0.11). The results of the study suggest that drain placement during open partial nephrectomy can safely be omitted, even in cases with violation of the collecting system. © 2016 The Japanese Urological Association.

  12. A novel transanal tube designed to prevent anastomotic leakage after rectal cancer surgery: the WING DRAIN.

    PubMed

    Nishigori, Hideaki; Ito, Masaaki; Nishizawa, Yuji

    2017-04-01

    We introduce a novel transanal tube (TAT), named the "WING DRAIN", designed to prevent anastomotic leakage after rectal cancer surgery, and report the fundamental experiments that led to its development. We performed the basic experiments to evaluate the effect of TATs on intestinal decompression, the changes they make in patterns of watery fluid drainage, the changes in their decompression effect when the extension tube connecting the TAT to the collection bag fills with watery drainage fluid, and the variations in intestinal contact and crushing pressure made by some types of TAT. Any type of TAT contributed to decompression in the intestinal tract. Watery drainage commenced from when the water level first rose to the hole in the tip of drain. The intestinal pressure increased with the length of the vertical twist in an extension tube. The crushing pressures of most types of TAT were high enough to cause injury to the intestine. We resolved the problems using an existing TAT for the purpose of intestinal decompression and by creating the first specialized TAT designed to prevent anastomotic leakage after rectal cancer surgery in Japan.

  13. Water quality in organic systems

    USDA-ARS?s Scientific Manuscript database

    Non-point source contamination is a major water quality concern in the upper Midwestern USA, where plant nutrients, especially NO3-N, are susceptible to leaching due to extensive subsurface draining of the highly productive, but poorly drained, soils found in this region. Environmental impacts assoc...

  14. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Air Force Plant 38, Porter, New York

    DTIC Science & Technology

    1988-04-01

    drainageways collect surface runoff at the plant and channel the water off plant property. These are: the Central Drain- age Ditch, the Magazine Ditch, and...past, this drain- age system collected test area deluge waters , small spills from test- ing areas, and drainage from around the flush and maintenance...Drain- age Ditch Table 4-2 shows the results of the analyses of two water samples and one soil/sediment sample that were obtained from the drainage from

  15. Lower pole anatomy and mid-renal-zone classification applied to flexible ureteroscopy: experimental study using human three-dimensional endocasts.

    PubMed

    Marroig, Bruno; Favorito, Luciano Alves; Fortes, Marco A; Sampaio, Francisco J B

    2015-12-01

    The aim of this study was to analyze the anatomy of the inferior pole collecting system and the mid-renal-zone classification in human endocasts applied to flexible ureteroscopy. 170 three-dimensional polyester resin endocasts of the kidney collecting system were obtained from 85 adult cadavers. We divided the endocasts into four groups: A1--kidney midzone (KM), drained by minor calices (mc) that are dependent on the superior or the inferior caliceal groups; A2--KM drained by crossed calices; B1--KM drained by a major caliceal group independent of both the superior and inferior groups; and B2--KM drained by mc entering directly into the renal pelvis. We studied the number of calices, the angle between the lower infundibulum and renal pelvis and the angle between the lower infundibulum and the inferior mc (LIICA). Means were statistically compared using ANOVA and the unpaired T test (p < 0.05). We found 57 (33.53 %) endocasts of group A1; 23 (13.53 %) of group A2; 59 (34.71 %) of group B1; and 31 (18.23 %) of group B2. The inferior pole was drained by four or more calices in 84 cases (49.41 %), distributed into groups as follows: A1 = 35 cases (41.67 %); A2 = 18 (21.43 %); B1 = 22 (26.19 %); and B2 = 9 (10.71 %). Perpendicular mc were observed in 15 cases (8.82 %). We did not observe statistical differences between the LIICA in the groups studied. Collector systems with kidney midzone drained by minor calices that are dependent on the superior or on the inferior caliceal groups presented at least two restrictive anatomical features. The mid-renal-zone classification was predictive of anatomical risk factors for lower pole ureteroscopy difficulties.

  16. Accounting for the risks of phosphorus losses through tile drains in a phosphorus index.

    PubMed

    Reid, D Keith; Ball, Bonnie; Zhang, T Q

    2012-01-01

    Tile drainage systems have been identified as a significant conduit for phosphorus (P) losses to surface water, but P indices do not currently account for this transport pathway in a meaningful way. Several P indices mention tile drains, but most account for either the reduction in surface runoff or the enhanced transport through tiles rather than both simultaneously. A summary of the current state of how tile drains are accounted for within P indices is provided, and the challenges in predicting the risk of P losses through tile drains that are relative to actual losses are discussed. A framework for a component P Index is described, along with a proposal to incorporate predictions of losses through tile drains as a component within this framework. Options for calibrating and testing this component are discussed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  17. Fabrication and Electrical Characterization of Deep-Submicron Trench-Isolated CMOS Device Structures.

    NASA Astrophysics Data System (ADS)

    Perera, Asanga Hiran

    The magnitude of the extrinsic parasitic MOSFET series resistance was experimentally evaluated in the deep -submicron domain and its consequence on device performance was determined. The series resistance of depletion mode MOSFET test structures were measured for source-drain sizes as small as 0.2 μm by 0.3 μm at room temperature and 100^ circK. To build the test structures a multilevel -full electron beam lithography fabrication process was developed with a pattern overlay accuracy of 75 nm. A new positive tone novalac resist, SYSTEM-9, was developed for electron beam application. The resist had moderate sensitivity, 19-30 muC/cm ^2, and a contrast up to 14. Interrupted development and reduced developer temperature resulted in contrast enhancements of up to 125%. SYSTEM-9 had a two or three times better dry etch resistance than PMMA. A shallow trench isolation technology capable of defining 0.2 μm wide active areas was developed. A rapid thermal annealing based silicidation scheme using TiSi_2 was established. MOSFET sidewall spacer formation using PECVD SiO_2 was calibrated. Antimony and gallium were investigated as possible alternatives to arsenic and boron, respectively, and well behaved substrate diodes were successfully fabricated. Two new patterning techniques for the metal bi-layer metalization of TiW and Al, based on liftoff and reactive ion etching, were developed. The source drain resistance of the test structures was measured at room temperature and at 100^ circK. An LN_2 flushed cold chuck for low temperature device probing was designed and constructed. The temperature dependence of the current voltage characteristics and the extracted series resistance proved that current flow in the contacts was tunneling dominated. The extrinsic source-drain resistance increased rapidly as the contact size decreased below 0.5 mum, and showed an almost two order of magnitude change, when the source-drain area was reduced from 2 x 1.7 mum^2 to 0.2 x 0.3 mum^2 . The effect of this resistance increase on a CMOS inverter switching speed was estimated. A first order empirical model to predict the series resistance was also formulated. Good correspondence was observed between results from the device simulator PISCES-2B and measured data for larger source-drain sizes.

  18. Modeling and analysis of sub-surface leakage current in nano-MOSFET under cutoff regime

    NASA Astrophysics Data System (ADS)

    Swami, Yashu; Rai, Sanjeev

    2017-02-01

    The high leakage current in nano-meter regimes is becoming a significant portion of power dissipation in nano-MOSFET circuits as threshold voltage, channel length, and gate oxide thickness are scaled down to nano-meter range. Precise leakage current valuation and meticulous modeling of the same at nano-meter technology scale is an increasingly a critical work in designing the low power nano-MOSFET circuits. We present a specific compact model for sub-threshold regime leakage current in bulk driven nano-MOSFETs. The proposed logical model is instigated and executed into the latest updated PTM bulk nano-MOSFET model and is found to be in decent accord with technology-CAD simulation data. This paper also reviews various transistor intrinsic leakage mechanisms for nano-MOSFET exclusively in weak inversion, like drain-induced barricade lowering (DIBL), gate-induced drain leakage (GIDL), gate oxide tunneling (GOT) leakage etc. The root cause of the sub-surface leakage current is mainly due to the nano-scale short channel length causing source-drain coupling even in sub-threshold domain. Consequences leading to carriers triumphing the barricade between the source and drain. The enhanced model effectively considers the following parameter dependence in the account for better-quality value-added results like drain-to-source bias (VDS), gate-to-source bias (VGS), channel length (LG), source/drain junction depth (Xj), bulk doping concentration (NBULK), and operating temperature (Top).

  19. Using MODFLOW drains to simulate groundwater flow in a karst environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, J.; Tomasko, D.; Glennon, M.A.

    1998-07-01

    Modeling groundwater flow in a karst environment is both numerically challenging and highly uncertain because of potentially complex flowpaths and a lack of site-specific information. This study presents the results of MODFLOW numerical modeling in which drain cells in a finite-difference model are used as analogs for preferential flowpaths or conduits in karst environments. In this study, conduits in mixed-flow systems are simulated by assigning connected pathways of drain cells from the locations of tracer releases, sinkholes, or other karst features to outlet springs along inferred flowpaths. These paths are determined by the locations of losing stream segments, ephemeral streammore » beds, geophysical surveys, fracture lineaments, or other surficial characteristics, combined with the results of dye traces. The elevations of the drains at the discharge ends of the inferred flowpaths are estimated from field data and are adjusted when necessary during model calibration. To simulate flow in a free-flowing conduit, a high conductance is assigned to each drain to eliminate the need for drain-specific information that would be very difficult to obtain. Calculations were performed for a site near Hohenfels, Germany. The potentiometric surface produced by the simulations agreed well with field data. The head contours in the vicinity of the karst features behaved in a manner consistent with a flow system having both diffuse and conduit components, and the sum of the volumetric flow out of the drain cells agreed closely with spring discharges and stream flows. Because of the success of this approach, it is recommended for regional studies in which little site-specific information (e.g., location, number, size, and conductivity of fractures and conduits) is available, and general flow characteristics are desired.« less

  20. Continuous 'Passive' Registration of Non-Point Contaminant Loads Via Agricultural Subsurface Drain Tubes

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J.; Jansen, S.; de Jonge, H.; Lindblad Vendelboe, A.

    2014-12-01

    Considering their crucial role in water and solute transport, enhanced monitoring and modeling of agricultural subsurface tube drain systems is important for adequate water quality management. For example, previous work in lowland agricultural catchments has shown that subsurface tube drain effluent contributed up to 80% of the annual discharge and 90-92% of the annual NO3 loads from agricultural fields towards the surface water. However, existing monitoring techniques for flow and contaminant loads from tube drains are expensive and labor-intensive. Therefore, despite the unambiguous relevance of this transport route, tube drain monitoring data are scarce. The presented study aimed developing a cheap, simple, and robust method to monitor loads from tube drains. We are now ready to introduce the Flowcap that can be attached to the outlet of tube drains and is capable of registering total flow, contaminant loads, and flow-averaged concentrations. The Flowcap builds on the existing SorbiCells, a modern passive sampling technique that measures average concentrations over longer periods of time (days to months) for various substances. By mounting SorbiCells in our Flowcap, a flow-proportional part of the drain effluent is sampled from the main stream. Laboratory testing yielded good linear relations (R-squared of 0.98) between drainage flow rates and sampling rates. The Flowcap was tested in practice for measuring NO3 loads from two agricultural fields and one glasshouse in the Netherlands. The Flowcap registers contaminant loads from tube drains without any need for housing, electricity, or maintenance. This enables large-scale monitoring of non-point contaminant loads via tube drains, which would facilitate the improvement of contaminant transport models and would yield valuable information for the selection and evaluation of mitigation options to improve water quality.

  1. Treatment of heavy metals by iron oxide coated and natural gravel media in Sustainable urban Drainage Systems.

    PubMed

    Norris, M J; Pulford, I D; Haynes, H; Dorea, C C; Phoenix, V R

    2013-01-01

    Sustainable urban Drainage Systems (SuDS) filter drains are simple, low-cost systems utilized as a first defence to treat road runoff by employing biogeochemical processes to reduce pollutants. However, the mechanisms involved in pollution attenuation are poorly understood. This work aims to develop a better understanding of these mechanisms to facilitate improved SuDS design. Since heavy metals are a large fraction of pollution in road runoff, this study aimed to enhance heavy metal removal of filter drain gravel with an iron oxide mineral amendment to increase surface area for heavy metal scavenging. Experiments showed that amendment-coated and uncoated (control) gravel removed similar quantities of heavy metals. Moreover, when normalized to surface area, iron oxide coated gravels (IOCGs) showed poorer metal removal capacities than uncoated gravel. Inspection of the uncoated microgabbro gravel indicated that clay particulates on the surface (a natural product of weathering of this material) augmented heavy metal removal, generating metal sequestration capacities that were competitive compared with IOCGs. Furthermore, when the weathered surface was scrubbed and removed, metal removal capacities were reduced by 20%. When compared with other lithologies, adsorption of heavy metals by microgabbro was 10-70% higher, indicating that both the lithology of the gravel, and the presence of a weathered surface, considerably influence its ability to immobilize heavy metals. These results contradict previous assumptions which suggest that gravel lithology is not a significant factor in SuDS design. Based upon these results, weathered microgabbro is suggested to be an ideal lithology for use in SuDS.

  2. Optical mass memories

    NASA Technical Reports Server (NTRS)

    Bailey, G. A.

    1976-01-01

    Optical and magnetic variants in the design of trillion-bit read/write memories are compared and tabulated. Components and materials suitable for a random access read/write nonmoving memory system are examined, with preference given to holography and photoplastic materials. Advantages and deficiencies of photoplastics are reviewed. Holographic page composer design, essential features of an optical memory with no moving parts, fiche-oriented random access memory design, and materials suitable for an efficient photoplastic fiche are considered. The optical variants offer advantages in lower volume and weight at data transfer rates near 1 Mbit/sec, but power drain is of the same order as for the magnetic variants (tape memory, disk memory). The mechanical properties of photoplastic film materials still leave much to be desired.

  3. Fabrication and Analysis of a Selectively Contacted Dual Channel High Electron Mobility Field-Effect Transistor

    NASA Astrophysics Data System (ADS)

    Khanna, Ravi

    1992-01-01

    A selectively contacted dual-channel high electron mobility transistor (SCD-CHEMT) has been designed, fabricated, and electrically characterized, in order to better understand the properties of two layers of two-dimensional electron gases (2DEGs) confined within a quantum well. The 2DEGs are placed under a Schottky barrier control gate which modulates their sheet charge densities, and by use of auxiliary Schottky barrier gates and two levels of ohmic contacts, electrical contacts to the individual channels in which each 2DEG resides is achieved. The design of the dual channel FET structure, and its practical realization by recourse to process development and fabrication are described, as are the techniques, results, and interpretations of electrical characterizations used to analyze the completed device. Critical fabrication procedures involving photolithography, etching, deposition, shallow and deep ohmic contact formation, and gate formation are developed, and a simple technique to reduce gate leakage by photo-oxidation is demonstrated. Analysis of the completed device is performed using one-dimensional band diagram simulations, magnetotransport and electrical measurements. Magnetotransport studies establish the existence of two 2DEGs within the quantum well at 4K. Drain current vs. drain voltage, and transconductance vs. gate voltage characteristics at room temperature confirm the presence of two 2DEGs and show that current flow between them occurs easily at room temperature. Carrier electron mobility profiles are taken of the 2DEGs and show that the lower 2DEG has a mobility comparable to that of a 2DEG formed at a normal interface, indicating that the "inverted interface problem" has been overcome. Capacitance vs. gate voltage measurements are taken, which are consistent with a simple device model consisting of gate depletion and interelectrode parasitic capacitances. It is concluded from the analysis that the dual channel system resides in three basic states: (1) Both channels are occupied by 2DEGs or (2) The upper channel is depleted, or (3) Both channels depleted. Finally, increase in isolation between the two 2DEGs is dramatically demonstrated at 77K by the drain current vs. drain voltage, and transconductance vs. gate voltage characteristics.

  4. 27. EXCAVATION OF EAST (FRONT) BASEMENT WELL AND DRAINAGE SYSTEM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. EXCAVATION OF EAST (FRONT) BASEMENT WELL AND DRAINAGE SYSTEM, WITH ARCHED ENTRY INTO BASEMENT UNDER FRONT ENTRY IN BACKGROUND, LOOKING NORTH (NOTE GALLETING IN BRICK FOUNDATION) BUT CLOSER RANGE SHOWING BRICK STRUCTURE WHICH CARRIED WATER FROM THE GUTTER DRAIN PIPE INTO THE BRICK DRAIN ALONG THE GROUND AND AWAY FROM THE FOUNDATION OF THE HOUSE - Belair, Tulip Grove Drive, Belair-at-Bowie, Bowie, Prince George's County, MD

  5. Influence of Scattering on Ballistic Nanotransistor Design

    NASA Technical Reports Server (NTRS)

    Anantram, M. P.; Svizhenko, Alexei; Biegel, Bryan, A. (Technical Monitor)

    2002-01-01

    Importance of this work: (1) This is the first work to model electron-phonon scattering within a quantum mechanical approach to nanotransistors. The simulations use the non equilibrium Green's function method. (2) A simple equation which captures the importance of scattering as a function of the spatial location from source to drain is presented. This equation helps interpret the numerical simulations. (3) We show that the resistance per unit length in the source side is much larger than in the drain side. Thus making scattering in the source side of the device much more important than scattering in the drain side. Numerical estimates of ballisticity for 10nm channel length devices in the presence of of electron-phonon scattering are given. Based on these calculations, we propose that to achieve a larger on-current in nanotransistors, it is crucial to keep the highly doped source extension region extremely small, even if this is at the cost of making the highly doped drain extension region longer.

  6. MOSES Support Platform

    DTIC Science & Technology

    2008-02-01

    drain with collector • Final pressure switch with gauge and automatic shut- off • (2) Hour meter • Oil filled finel pressure gauge 0~400bar/5800psi...Automatic condensate drain system Final pressure switch with gauge and automatic shut-off (2) Hour meter, (2) On/Off Switch Filling Connection Four

  7. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other junction boxes (e.g., manholes, sumps, and lift stations) conveying regulated-material. For the purpose of... segregated from all other individual drain systems. Junction box means a sump, manhole, or access point to a...

  8. [Sterility in drained serums; before their use in emergency wards and in non-hospital emergency use].

    PubMed

    Carrasco, Juan Antonio Péculo; Escorza, Juana Gómez; Sánchez, María Del Mar Casal; Bouza, Mónica Rodríguez; Sanchez, José Luis Avecilla; Ruiz, Hugo José Rodríguez

    2008-01-01

    The authors detail the characteristics for the sterility of drained serums placed in a mobile emergency service unit and they determine how much time they can maintain optimum conditions for the use of these serums by means of a controlled, random, triple blind clinical test in which the units studied were serums prepared by an infusion system and a three-way valve. Data were gathered during a 12 month study period. The authors designed six operating groups based on their exposure time and where they were kept. These samples totaled 672 units. The authors carried out 12 microbiological cultural analyses for each unit; these analyses were tested for bacteria and fungi, both aerobic and anaerobic. The authors contrasted their hypothesis with a multivariable logistic regression model used as the variable for sterility A value of p < 0.05 was considered to be significant. Results were obtained on 669 serums, 98.82% of samples. Colonization was found in 1.7% of the 8028 cultures analyzed; in only 2 cases was there a register greater than 10 UFC/ml. This colonization corresponded to 103 serums which were then classified as non-sterile. For sterility the logistic regression model did not show any significant association with the various operating groups, which were controlled by means of two possible variable methods. The authors did not find evidence that recently drained serums were different, from the point of view of sterility, than the serums exposed during 24, 48 or 72 hours but, as well as for the groups, the incidences of these serums tripled the risk of colonization. The authors concluded they could use serums prepared previously and these serums sterility were guaranteed to the same degree as recently drained serums.

  9. Tests of oil scraper piston ring and piston fitted with oil drain holes

    NASA Technical Reports Server (NTRS)

    Mcdewell, H S

    1922-01-01

    Tests were conducted to determine whether or not a properly located and properly designed oil scraper piston ring, installed on a piston provided with oil drain holes of sufficient area, would prevent the excessive oiling of the Liberty engine, particularly with the engine running at idling speed with full oil pressure. Results showed that excessive oiling was in fact prevented. It is strongly recommended that scraper rings and pistons be adopted for aircraft engines.

  10. The Profile of Student Misconceptions on The Human and Plant Transport Systems

    NASA Astrophysics Data System (ADS)

    Ainiyah, M.; Ibrahim, M.; Hidayat, M. T.

    2018-01-01

    This research aims to identify misconceptions on the humans and plants transportation systems. The research was done in the 8th grade in Indonesia. Data were collected to use a three-tier test. This type of research was used survey design. Content analysis was used to analyze the misconception data. The results of this research were the location of misconception of each student is different. The highest misconceptions identified in this research, namely: a) arteries that drain blood to the heart (73.3%); b) veins that drain blood from the heart (70.0%); c) place of oxygen and carbon dioxide exchange occurs in the veins (66.7%); d) blood pressure in veins greater than in capillaries (63.3%); e) absorption of water occurs diffusion and absorption of minerals occurs osmosis (76.7%); f) transport of photosynthesis process occurs by diffusion (66.7%); g) photosynthesis process occurs during the day (63.3%); and h) process of evaporation of water through the leaves are guttation (56.7%). The results of this research show that the level of students misconceptions on the of human and plant transport systems is still high so that it can serve as a reference to improve the learning process and the reduction of student misconceptions.

  11. Left Superior Vena Cava Draining Into Left Atrium in Tetralogy of Fallot-Four Cases of a Rare Association.

    PubMed

    Ramman, Tarun Raina; Dutta, Nilanjan; Chowdhuri, Kuntal Roy; Agrawal, Sunny; Girotra, Sumir; Azad, Sushil; Radhakrishnan, Sitaraman; Iyer, Parvathi Unninayar; Iyer, Krishna Subramony

    2018-01-01

    Persistent left superior vena cava is a common congenital anomaly of the thoracic venous system. Left superior vena cava draining into left atrium is a malformation of sinus venosus and caval system. The anomaly may be a cause of unexplained hypoxia even in adults. It may give rise to various diagnostic and technical challenges during cardiac catheterization and open-heart surgery. It is often detected serendipitously during diagnostic workup. Isolated left superior vena cava opening into left atrium is very commonly associated with other congenital heart defects. But tetralogy of Fallot is very rarely associated with persistent left superior vena cava which drains into left atrium. We report four such cases who underwent surgical correction successfully.

  12. Corn yield under subirrigation and future climate scenarios in the Maumee river basin

    USDA-ARS?s Scientific Manuscript database

    Subirrigation has been proposed as a water table management practice to maintain appropriate soil water content during periods of high crop water demand on subsurface drained croplands in the Corn Belt. Subirrigation takes advantage of the subsurface drainage systems already installed on drained agr...

  13. Sewage Disposal in Port Harcourt, Nigeria.

    ERIC Educational Resources Information Center

    Ayotamuno, M. J.

    1993-01-01

    This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…

  14. Remaining Sites Verification Package for the 118-C-3:3, 105-C French Drains, Waste Site Reclassification Form 2006-016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. A. Carlson

    2006-04-24

    The 118-C-3:3 french drains received condensate from the steam heating system in the 105-C Reactor Building. The 118-C-3:3 french drain meets the remedial action objectives specified in the Remaining Sites ROD. The results demonstrate that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  15. The Portal Theory Supported by Venous Drainage–Selective Fat Transplantation

    PubMed Central

    Rytka, Julia M.; Wueest, Stephan; Schoenle, Eugen J.; Konrad, Daniel

    2011-01-01

    OBJECTIVE The “portal hypothesis” proposes that the liver is directly exposed to free fatty acids and cytokines increasingly released from visceral fat tissue into the portal vein of obese subjects, thus rendering visceral fat accumulation particularly hazardous for the development of hepatic insulin resistance and type 2 diabetes. In the present study, we used a fat transplantation paradigm to (artificially) increase intra-abdominal fat mass to test the hypothesis that venous drainage of fat tissue determines its impact on glucose homeostasis. RESEARCH DESIGN AND METHODS Epididymal fat pads of C57Bl6/J donor mice were transplanted into littermates, either to the parietal peritoneum (caval/systemic venous drainage) or, by using a novel approach, to the mesenterium, which confers portal venous drainage. RESULTS Only mice receiving the portal drained fat transplant developed impaired glucose tolerance and hepatic insulin resistance. mRNA expression of proinflammatory cytokines was increased in both portally and systemically transplanted fat pads. However, portal vein (but not systemic) plasma levels of interleukin (IL)-6 were elevated only in mice receiving a portal fat transplant. Intriguingly, mice receiving portal drained transplants from IL-6 knockout mice showed normal glucose tolerance. CONCLUSIONS These results demonstrate that the metabolic fate of intra-abdominal fat tissue transplantation is determined by the delivery of inflammatory cytokines to the liver specifically via the portal system, providing direct evidence in support of the portal hypothesis. PMID:20956499

  16. Heterotrophic bacteria in an air-handling system.

    PubMed Central

    Hugenholtz, P; Fuerst, J A

    1992-01-01

    Heterotrophic bacteria from structural surfaces, drain pan water, and the airstream of a well-maintained air-handling system with no reported building-related illness were enumerated. Visually the system appeared clean, but large populations of bacteria were found on the fin surface of the supply-side cooling coils (10(5) to 10(6) CFU cm-2), in drain pan water (10(5) to 10(7) CFU ml-1), and in the sump water of the evaporative condenser (10(5) CFU ml-1). Representative bacterial colony types recovered from heterotrophic plate count cultures on R2A medium were identified to the genus level. Budding bacteria belonging to the genus Blastobacter dominated the supply surface of the coil fins, the drain pan water, and the postcoil air. These data and independent scanning electron microscopy indicated that a resident population of predominantly Blastobacter bacteria was present as a biofilm on the supply-side cooling coil fins. Images PMID:1476435

  17. Heterotrophic bacteria in an air-handling system.

    PubMed

    Hugenholtz, P; Fuerst, J A

    1992-12-01

    Heterotrophic bacteria from structural surfaces, drain pan water, and the airstream of a well-maintained air-handling system with no reported building-related illness were enumerated. Visually the system appeared clean, but large populations of bacteria were found on the fin surface of the supply-side cooling coils (10(5) to 10(6) CFU cm-2), in drain pan water (10(5) to 10(7) CFU ml-1), and in the sump water of the evaporative condenser (10(5) CFU ml-1). Representative bacterial colony types recovered from heterotrophic plate count cultures on R2A medium were identified to the genus level. Budding bacteria belonging to the genus Blastobacter dominated the supply surface of the coil fins, the drain pan water, and the postcoil air. These data and independent scanning electron microscopy indicated that a resident population of predominantly Blastobacter bacteria was present as a biofilm on the supply-side cooling coil fins.

  18. GIDL analysis of the process variation effect in gate-all-around nanowire FET

    NASA Astrophysics Data System (ADS)

    Kim, Shinkeun; Seo, Youngsoo; Lee, Jangkyu; Kang, Myounggon; Shin, Hyungcheol

    2018-02-01

    In this paper, the gate-induced drain leakage (GIDL) is analyzed on gate-all-around (GAA) Nanowire FET (NW FET) with ellipse-shaped channel induced by process variation effect (PVE). The fabrication process of nanowire can lead to change the shape of channel cross section from circle to ellipse. The effect of distorted channel shape is investigated and verified by technology computer-aided design (TCAD) simulation in terms of the GIDL current. The simulation results demonstrate that the components of GIDL current are two mechanisms of longitudinal band-to-band tunneling (L-BTBT) at body/drain junction and transverse band-to-band tunneling (T-BTBT) at gate/drain junction. These two mechanisms are investigated on channel radius (rnw) and aspect ratio of ellipse-shape respectively and together.

  19. Effects of land use on greenhouse gas fluxes and soil properties of wetland catchments in the Prairie Pothole Region of North America

    USGS Publications Warehouse

    Tangen, Brian A.; Finocchiaro, Raymond G.; Gleason, Robert A.

    2015-01-01

    Results suggest that soil organic carbon is lost when relatively undisturbed catchments are converted for agriculture, and that when non-drained cropland catchments are restored, CH4 fluxes generally are not different than the pre-restoration baseline. Conversely, when drained cropland catchments are restored, CH4 fluxes are noticeably higher. Consequently, it is important to consider the type of wetland restoration (drained, non-drained) when assessing restoration benefits. Results also suggest that elevated N2O fluxes from cropland catchments likely would be reduced through restoration. The overall variability demonstrated by this study was consistent with findings of other wetland investigations and underscores the difficulty in quantifying the GHG balance of wetland systems.

  20. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology.

    PubMed

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-10-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3(+) CD4(+) CD8(-) , CD3(+) CD4(-) CD8(+) and human leucocyte antigen D-related (HLA-DR)(+) CD19(+) lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1-2 post-Itx, analysis by short tandem repeats fingerprinting of CD3(+) CD8(+) sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. © 2010 The Authors. Clinical and Experimental Immunology © 2010 British Society for Immunology.

  1. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology

    PubMed Central

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-01-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3+CD4+CD8-, CD3+CD4-CD8+ and human leucocyte antigen D-related (HLA-DR)+CD19+ lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1–2 post-Itx, analysis by short tandem repeats fingerprinting of CD3+CD8+ sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. PMID:20831713

  2. High work function materials for source/drain contacts in printed polymer thin film transistors

    NASA Astrophysics Data System (ADS)

    Sholin, V.; Carter, S. A.; Street, R. A.; Arias, A. C.

    2008-02-01

    Studies of materials for source-drain electrodes in ink-jet printed polymer-based thin film transistors (TFTs) are reported. Two systems are studied: a blend of Ag nanoparticles with poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) and an ethylene glycol-doped PEDOT:PSS solution (modified-PEDOT). The semiconductor used is the polythiophene derivative poly [5,5'-bis(3-dodecyl-2-thienyl)-2,2,2'-bithiophene]. PEDOT:Ag blends and modified-PEDOT yield TFTs with mobilities around 10-2 and 10-3cm2/Vs, respectively, subthreshold slopes around 1.6V/decade and on-to-off current ratios of 106-107. Both systems show considerable improvement over printed TFTs with Ag nanoparticle source-drain electrodes. Results on film resistivity and morphology are discussed along with device characteristic analysis.

  3. Processing of Lewisite munitions in the explosive destruction system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepodd, Timothy J.; Didlake, John E., Jr.; Bradshaw, Robert W., PhD

    2005-03-01

    The Explosive Destruction System (EDS) is a transportable system designed to treat chemical munitions. The EDS is transported on an open trailer that provides a mounting surface for major system components and an operator's work platform. The trailer is towed by a prime mover. An explosive containment vessel contains the shock, munition fragments, and the chemical agent during the munition opening process, and then provides a vessel for the subsequent chemical treatment of the agent. A fragmentation suppression system houses the chemical munition and protects the containment vessel from high velocity fragments. An explosive accessing system uses shaped charges tomore » cut the munition open and attack the burster. A firing system detonates the shaped charges. A chemical feed system supplies neutralizing reagents and water to the containment vessel. A waste handling system drains the treated effluent.« less

  4. Design and simulation of a novel 1400 V-4000 V enhancement mode buried gate GaN HEMT for power applications

    NASA Astrophysics Data System (ADS)

    Faramehr, Soroush; Kalna, Karol; Igić, Petar

    2014-11-01

    A novel enhancement mode structure, a buried gate gallium nitride (GaN) high electron mobility transistor (HEMT) with a breakdown voltage (BV) of 1400 V-4000 V for a source-to-drain spacing (LSD) of 6 μm-32 μm, is investigated using simulations by Silvaco Atlas. The simulations are based on meticulous calibration of a conventional lateral 1 μm gate length GaN HEMT with a source-to-drain spacing of 6 μm against its experimental transfer characteristics and BV. The specific on-resistance RS for the new power transistor with the source-to-drain spacing of 6 μm showing BV = 1400 V and the source-to-drain spacing of 8 μm showing BV = 1800 V is found to be 2.3 mΩ · cm2 and 3.5 mΩ · cm2, respectively. Further improvement up to BV = 4000 V can be achieved by increasing the source-to-drain spacing to 32 μm with the specific on-resistance of RS = 35.5 mΩ · cm2. The leakage current in the proposed devices stays in the range of ˜5 × 10-9 mA mm-1.

  5. Endoscopic, single-catheter treatment of Dandy-Walker syndrome hydrocephalus: technical case report and review of treatment options.

    PubMed

    Sikorski, Christian W; Curry, Daniel J

    2005-01-01

    Optimal treatment for hydrocephalus related to Dandy-Walker syndrome (DWS) remains elusive. Patients with DWS-related hydrocephalus often require combinations of shunting systems to effectively drain both the supratentorial ventricles and posterior fossa cyst. We describe an endoscopic technique, whereby a frontally placed, single-catheter shunting system effectively drained the supratentorial and infratentorial compartments. This reduces the complexity and potential risk associated with the combined shunting systems required by so many with DWS-related hydrocephalus. Copyright 2005 S. Karger AG, Basel.

  6. 76 FR 64801 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    .... But we might have found it necessary to use different words from those in the MCAI to ensure the AD is... blocked by water, which fails to enter the drain bottles. Investigation revealed that drain bottles used in the primary pitot-static system include check valves, which impede the entry of water into the...

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  8. Restructuring brain drain: strengthening governance and financing for health worker migration

    PubMed Central

    Mackey, Tim K.; Liang, Bryan A.

    2013-01-01

    Background Health worker migration from resource-poor countries to developed countries, also known as ‘‘brain drain’’, represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Methods Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Results Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. Conclusions In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed. PMID:23336617

  9. Assembly and Thermal Hydraulic Test of a Stainless Steel Sodium-Potassium Circuit

    NASA Technical Reports Server (NTRS)

    Garber, A.; Godfroy, T.; Webster, K.

    2007-01-01

    Early Flight Fission Test Facilities (EFF-TF) team has been tasked by the NASA Marshall Space Flight Center Nuclear Systems Office to design, fabricate, and test an actively pumped alkali metal flow circuit. The system was originally built for use with lithium, but due to a shift in focus, it was redesigned for use with a eutectic mixture of sodium potassium (NaK). Basic circuit components include: reactor segment, NaK to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and a spill reservoir. A 37-pin partial-array core (pin and flow path dimensions are the same as those in a full design) was selected for fabrication and test. This paper summarizes the first fill and checkout testing of the Stainless Steel NaK-Cooled Circuit (SNaKC).

  10. N loss to drain flow and N2O emissions from a corn-soybean rotation with winter rye.

    PubMed

    Gillette, K; Malone, R W; Kaspar, T C; Ma, L; Parkin, T B; Jaynes, D B; Fang, Q X; Hatfield, J L; Feyereisen, G W; Kersebaum, K C

    2018-03-15

    Anthropogenic perturbation of the global nitrogen cycle and its effects on the environment such as hypoxia in coastal regions and increased N 2 O emissions is of increasing, multi-disciplinary, worldwide concern, and agricultural production is a major contributor. Only limited studies, however, have simultaneously investigated NO 3 - losses to subsurface drain flow and N 2 O emissions under corn-soybean production. We used the Root Zone Water Quality Model (RZWQM) to evaluate NO 3 - losses to drain flow and N 2 O emissions in a corn-soybean system with a winter rye cover crop (CC) in central Iowa over a nine year period. The observed and simulated average drain flow N concentration reductions from CC were 60% and 54% compared to the no cover crop system (NCC). Average annual April through October cumulative observed and simulated N 2 O emissions (2004-2010) were 6.7 and 6.0kgN 2 O-Nha -1 yr -1 for NCC, and 6.2 and 7.2kgNha -1 for CC. In contrast to previous research, monthly N 2 O emissions were generally greatest when N loss to leaching were greatest, mostly because relatively high rainfall occurred during the months fertilizer was applied. N 2 O emission factors of 0.032 and 0.041 were estimated for NCC and CC using the tested model, which are similar to field results in the region. A local sensitivity analysis suggests that lower soil field capacity affects RZWQM simulations, which includes increased drain flow nitrate concentrations, increased N mineralization, and reduced soil water content. The results suggest that 1) RZWQM is a promising tool to estimate N 2 O emissions from subsurface drained corn-soybean rotations and to estimate the relative effects of a winter rye cover crop over a nine year period on nitrate loss to drain flow and 2) soil field capacity is an important parameter to model N mineralization and N loss to drain flow. Published by Elsevier B.V.

  11. Reducing sediment inputs to Scottish streams: a review of the efficacy of soil conservation practices in upland forestry.

    PubMed

    Carling, P A; Irvine, B J; Hill, A; Wood, M

    2001-01-29

    The historical process by which a soil conservation strategy has evolved within the UK forestry industry is briefly reviewed. Particular attention is given to the development of practical and effective guidelines to prevent both soil damage and sediment entering water courses. It is concluded that the 'Forest and Water Guidelines', together with other forest industry manuals, largely provide adequate protection for aquatic habitats from pre-afforestation cultivation and from harvesting activities. The problem of soil erosion owing to ploughing of open furrows has largely been obviated by improved drainage network design coupled with the use of vegetated buffer strips and sediment catchpits. Alternative site preparation techniques, such as 'moling' or 'dolloping' of afforestation sites, are now preferred. However, the effects on slope hydrology and the improved soil conservation associated with these methods require quantifying. Additional understanding of effective buffer strip function, for example, on a variety of slope angles, soil types and vegetation associations would be beneficial. The design of forest roads and the associated network of drains, culverts and sediment catchpits is addressed in forestry guidelines. Future potential in this area may involve the use of Geographical Information Systems in the effective design of road networks which minimise adverse effects on slope hydrology. Similarly computer simulation of flow routing might aid in the design of road drain networks. At the more local scale there remains scope for further research aimed at minimising soil disturbance by machinery. Consideration should also be given to the long-term sustainability of the soil structure through second and subsequent crop rotations.

  12. Propellant Management and Conditioning within the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Brown, T. M.; McDonald, J. P.; Hedayat, A.; Knight, K. C.; Champion, R. H., Jr.

    1998-01-01

    The X-34 hypersonic flight vehicle is currently under development by Orbital Sciences Corporation (Orbital). The Main Propulsion ystem as been designed around the liquid propellant Fastrac rocket engine currently under development at NASA Marshall Space Flight Center. This paper presents analyses of the MPS subsystems used to manage the liquid propellants. These subsystems include the propellant tanks, the tank vent/relief subsystem, and the dump/fill/drain subsystem. Analyses include LOX tank chill and fill time estimates, LOX boil-off estimates, propellant conditioning simulations, and transient propellant dump simulations.

  13. Evaluating Riparian and Agricultural Systems as Sinks for Surface Water Nutrients in the Upper Rio Grande

    NASA Astrophysics Data System (ADS)

    Oelsner, G. P.; Brooks, P. D.; Hogan, J. F.; Phillips, F. M.; Villinski, J. E.

    2005-12-01

    We have performed five years of biannual synoptic sampling along a 1200km reach of the Rio Grande to develop relationships between discharge, land use, and major water quality parameters. Both total dissolved nitrogen (TDN) and dissolved organic carbon (DOC) concentrations gradually increase with distance downstream, however for TDN and phosphate this trend is punctuated by large, localized inputs primarily from urban wastewater. Somewhat surprisingly, surface water draining from areas of intensive, irrigated agriculture during the growing season often had lower nutrient and DOC concentrations than the river. To better quantify the effects of urban and agricultural systems on water quality we conducted three years of higher spatial resolution sampling of a 250km reach (between Cochiti Dam and Elephant Butte Reservoir) that contains both major agricultural and urban water users. During the higher flow years of 2001 and 2005 TDN concentrations in the river were higher (x = 1.19mg/L, SD = 0.21) than in the drier years 2002-2004 (x = 0.52mg/L, SD = 0.42). TDN concentrations decreased from 1.97mg/L to 0.78 mg/L in a 5km reach below the Albuquerque wastewater treatment plant during the low discharge year of 2004, but there was little to no decrease in TDN concentrations over the 180km below the wastewater treatment plant in years with higher river discharge. In contrast, water diverted to agricultural fields and returned to the river in drains experienced a 60% reduction in TDN concentrations in dry years and a 30% reduction in wet years compared to initial river water. During the dry years, water in the conveyance channel appears to be a mixture of river and drain water whereas in wetter years the conveyance channel has a lower average TDN concentration than either the river or the drains. These data suggest that the river-riparian-hyporheic system of the Rio Grande can serve at best as a weak N sink, while the combination of agricultural fields and drains serve as a strong nutrient sink. Ongoing research is quantifying the locations and potential rates of N transformation in both the river and agricultural drain systems.

  14. Dissolved organic carbon in runoff and tile-drain water under corn and forage fertilized with hog manure.

    PubMed

    Royer, Isabelle; Angers, Denis A; Chantigny, Martin H; Simard, Régis R; Cluis, Daniel

    2007-01-01

    Dissolved organic carbon (DOC) export from soils can play a significant role in soil C cycling and in nutrient and pollutant transport. However, information about DOC losses from agricultural soils as influenced by management practices is scarce. We compared the effects of mineral fertilizer (MF) and liquid hog manure (LHM) applications on the concentration and molecular size of DOC released in runoff and tile-drain water under corn (Zea mays L.) and forage cropping systems. Runoff and tile-drain water samples were collected during a 2-mo period (October to December 1998) and DOC concentration was measured. Characterization of DOC was performed by tangential ultrafiltration with nominal cut-offs at 3 and 100 kDa. Mean concentration of DOC in runoff water (12.7 mg DOC L(-1)) was higher than in tile-drain water (6.5 mg DOC L(-1)). Incorporation of corn residues increased the DOC concentration by 6- to 17-fold in surface runoff, but this effect was short-lived. In runoff water, the relative size of the DOC molecules increased when corn residues and LHM were applied probably due to partial microbial breakdown of these organic materials and to a faster decomposition or preferential adsorption of the small molecules. The DOC concentration in tile-drain water was slightly higher under forage (7.5 mg DOC L(-1)) than under corn (5.4 mg DOC L(-1)) even though the application rates of LHM were higher in corn plots. We suggest that preferential flow facilitated the migration of DOC to tile drains in forage plots. In conclusion, incorporation of corn residues and LHM increased the concentration of DOC and the relative size of the molecules in surface runoff water, whereas DOC in tile-drain water was mostly influenced by the cropping system with relatively more DOC and larger molecules under forage than corn.

  15. Effects of trap-assisted tunneling on gate-induced drain leakage in silicon-germanium channel p-type FET for scaled supply voltages

    NASA Astrophysics Data System (ADS)

    Tiwari, Vishal A.; Divakaruni, Rama; Hook, Terence B.; Nair, Deleep R.

    2016-04-01

    Silicon-germanium is considered as an alternative channel material to silicon p-type FET (pFET) for the development of energy efficient high performance transistors for 28 nm and beyond in a high-k metal gate technology because of its lower threshold voltage and higher mobility. However, gate-induced drain leakage (GIDL) is a concern for high threshold voltage device design because of tunneling at reduced bandgap. In this work, the trap-assisted tunneling and band-to-band tunneling (BTBT) effects on GIDL is analyzed and modeled for SiGe pFETs. Experimental results and Monte Carlo simulation results reveal that the pre-halo germanium pre-amorphization implant used to contain the short channel effects contribute to GIDL at the drain sidewall in addition to GIDL due to BTBT in SiGe devices. The results are validated by comparing the experimental observations with the numerical simulation and a set of calibrated models are used to describe the GIDL mechanisms for various drain and gate bias.

  16. Monogroove liquid heat exchanger

    NASA Technical Reports Server (NTRS)

    Brown, Richard F. (Inventor); Edelstein, Fred (Inventor)

    1990-01-01

    A liquid supply control is disclosed for a heat transfer system which transports heat by liquid-vapor phase change of a working fluid. An assembly (10) of monogroove heat pipe legs (15) can be operated automatically as either heat acquisition devices or heat discharge sources. The liquid channels (27) of the heat pipe legs (15) are connected to a reservoir (35) which is filled and drained by respective filling and draining valves (30, 32). Information from liquid level sensors (50, 51) on the reservoir (35) is combined (60) with temperature information (55) from the liquid heat exchanger (12) and temperature information (56) from the assembly vapor conduit (42) to regulate filling and draining of the reservoir (35), so that the reservoir (35) in turn serves the liquid supply/drain needs of the heat pipe legs (15), on demand, by passive capillary action (20, 28).

  17. Switches from pi- to sigma-bonding complexes controlled by gate voltages.

    PubMed

    Matsui, Eriko; Harnack, Oliver; Matsuzawa, Nobuyuki N; Yasuda, Akio

    2005-10-01

    A conjugated polymer/metal ion/liquid-crystal molecular system was set between source and drain electrodes with a 100 nm gap. When gate voltage (Vg) increases, the current between source and drain electrodes increases. Infrared spectra show this system to be composed of pi and sigma complexes. At Vg = 0, the pi complex dominates the sigma complex, whereas the sigma complex becomes dominant when Vg is switched on. Calculations found that the pi complex has lower conductivity than the sigma complex.

  18. JMU Refuses to Let Money Go down the Drain

    ERIC Educational Resources Information Center

    McGuinn, Joseph P.

    2012-01-01

    James Madison University (JMU) in Harrisonburg, Virginia has embarked on a rational means to reduce energy costs and provides a sustainable approach to student housing. The investment to install a Drain Water Heat Recovery system (DWHR) at Wayland Hall is estimated to pay for itself in less than three years but will provide dividends for over 40.…

  19. Control of Culex quinquefasciatus in a storm drain system in Florida with attractive toxic sugar baits (ATSB)

    USDA-ARS?s Scientific Manuscript database

    Mosquitoes of the Culex pipiens group, including Culex quinquefasciatus, are important vectors of West Nile virus and other viruses around the world. Control of these mosquitoes in urban areas is often difficult because of the use of storm drains and other man-made structures as larval habitats. I...

  20. Management of maxillectomy defect with a hybrid hollow bulb obturator

    PubMed Central

    Singh, Kamleshwar; Singh, Saumyendra V; Mishra, Niraj; Agrawal, Kaushal Kishor

    2013-01-01

    A woman having already undergone maxillectomy came to the department complaining of difficulty in eating and speech. During the construction of an obturator, the bulb area should be hollowed to reduce weight so that the teeth and supporting tissues are not stressed unnecessarily. The conventional open design drains fluid from the adjacent mucosa, possibly increasing the weight of the prosthesis, and is difficult to clean. The closed bulb design does not drain secretions and may cause obstruction and susceptibility to infection in the paranasal and pharyngeal regions, though it is easier to maintain. An alternative to the two designs, combining their advantages, is presented in this report. As the open hollow part of the obturator was shallow, it was easy to clean. Making the inferior part of the bulb hollow and closed led to a reduction in the overall weight of the prosthesis while increasing its resonance. PMID:23436886

  1. An alternative tensiometer design for deep vadose zone monitoring

    NASA Astrophysics Data System (ADS)

    Moradi, A. B.; Kandelous, M. M.; Hopmans, J. W.

    2015-12-01

    The conventional tensiometer is among the most accurate devices for soil water matric potential measurements, as well as for estimations of soil water flux from soil water potential gradients. Uncertainties associated with conventional tensiometers such as caused by ambient temperature effects and the draining of the tensiometer tube, as well as their limitation for deep soil monitoring has prevented their widespread use for vadose zone monitoring, despite their superior accuracy, in general. We introduce an alternative tensiometer design that offers the accuracy of the conventional tensiometer, while minimizing afore-mentioned uncertainties and limitations. The proposed alternative tensiometer largely eliminates temperature-induced diurnal fluctuations and uncertainties associated with the draining of the tensiometer tube, and removes the limitation in installation depth. In addition, the manufacturing costs of this alternative tensiometer design is close to that of the conventional tensiometer, while it is especially suited for monitoring of soil water potential gradients as required for soil water flux measurements.

  2. A linked lake system beneath Thwaites Glacier, West Antarctica reveals an efficient mechanism for subglacial water flow.

    NASA Astrophysics Data System (ADS)

    Smith, B. E.; Gourmelen, N.; Huth, A.; Joughin, I. R.

    2016-12-01

    In this presentation we show the results of a multi-sensor survey of a system of subglacial lakes beneath Thwaites Glacier, West Antarctica. This is the first substantial active (meaning draining or filling on annual time scales) lake system detected under the fast-flowing glaciers of the Amundsen Coast. Altimetry data show that over the 2013 calendar year, four subglacial lakes drained, essentially simultaneously, with the bulk of the drainage taking place over the course the first three months of the year. The largest of the lakes appears to have drained around 3.7 km3 of water, with the others each draining less than 1 km3. The high-resolution radar surveys conducted in this area by NASA's IceBridge program allow detailed analysis of the subglacial hydrologic potential, which shows that the potential map in this area is characterized by small closed basins that should not, under the common assumption that water flow is directed down the gradient of the hydropotential, allow long-range water transport. The lakes' discharge demonstrates that, at least in some cases, water can flow out of apparently closed hydropotential basins. Combining a basal-flow routing map with a map of basal melt production suggests that the largest drainage event could recur as often as every 22 years, provided that overflow or leakage of mapped hydropotential basins allows melt water transport to refill the lake. An analysis of ice-surface speed records both around the lakes and at the Thwaites grounding line shows small changes in ice speed, but none clearly associated with the drainage event, suggesting that, at least in this area where subglacial melt is abundant, the addition of further water to the subglacial hydrologic system need not have any significant effect on ice flow. It is likely that the main impact of the lake system on the glacier is that as an efficient mechanism to remove meltwater from the system, it drains water that would otherwise flow through less efficient, distributed systems that would be more effective in lubricating the base of the glacier.

  3. Continuous Passive Sampling of Solutes from Agricultural Subsurface Drainage Tubes

    NASA Astrophysics Data System (ADS)

    Lindblad Vendelboe, Anders; de Jonge, Hubert; Rozemeijer, Joachim; Wollesen de Jonge, Lis

    2015-04-01

    Agricultural subsurface tube drain systems play an important role in water and solute transport. One study, focusing on lowland agricultural catchments, showed that subsurface tube drainage contributed up to 80% of the annual discharge and 90% of the annual NO3 load from agricultural fields to the receiving water bodies. Knowledge of e.g. nutrient loads and drainage volumes, based on measurements and modelling, are important for adequate water quality management. Despite the importance of tube drain transport of solutes, monitoring data are scarce. This scarcity is a result of the existing monitoring techniques for flow and contaminant load from tube drains being expensive and labor-extensive. The study presented here aimed at developing a cheap, simple, and robust method to monitor solute loads from tube drains. The method is based on the newly developed Flowcap, which can be attached to existing tube drain outlets and can measure total flow, contaminant load and flow-averaged concentrations of solutes in the drainage. The Flowcap builds on the existing Sorbicell principle, a passive sampling system that measures average concentrations over longer periods of time (days to months) for various compounds. The Sorbicell consists of two compartments permeable to water. One compartment contains an adsorbent and one contains a tracer. When water passes through the Sorbicell the compound of interest is absorbed while a tracer is released. Using the tracer loss to calculate the volume of water that has passed the Sorbicell it is possible to calculate the average concentration of the compound. When mounting Sorbicells in the Flowcap, a flow-proportional part of the drainage is sampled from the main stream. To accommodate the wide range of drainage flow rates two Flowcaps with different capacities were tested in the laboratory: one with a capacity of 25 L min-1 (Q25) and one with a capacity of 256 L min-1 (Q256). In addition, Sorbicells with two different hydraulic resistances were tested, again to accommodate a large range of potential drainage flows rates. The experiment was continued until the Sorbicell's capacity was exhausted, which gave experimentation times from 6 to 34 days, while continuously changing the drainage flow rate to simulate field drainage conditions, and to test the range of the Flowcap. The laboratory testing yielded a very good linear correlation between drainage flow rates and Sorbicell sampling rates, giving r = 0.99 for both the Q25 and the Q256 Flowcap. The Sorbicells in this experiment were designed to measure NO3, but the Flowcap can be used with any Sorbicell and thus be used to measure any compound of interest. The Flowcap does not need housing, electricity, or maintenance and continuously register drainage volumes and contaminant loads for periods up to one month. This, in addition to the low cost of the monitoring system, enables large-scale monitoring of contaminant loads via tube drains, giving valuable data for the improvement of contaminant transport models. Further, these data will help select and evaluate the different mitigation option to improve water quality.

  4. Regression Techniques for Determining the Effective Impervious Area in Southern California Watersheds

    NASA Astrophysics Data System (ADS)

    Sultana, R.; Mroczek, M.; Dallman, S.; Sengupta, A.; Stein, E. D.

    2016-12-01

    The portion of the Total Impervious Area (TIA) that is hydraulically connected to the storm drainage network is called the Effective Impervious Area (EIA). The remaining fraction of impervious area, called the non-effective impervious area, drains onto pervious surfaces which do not contribute to runoff for smaller events. Using the TIA instead of EIA in models and calculations can lead to overestimates of runoff volumes peak discharges and oversizing of drainage system since it is assumed all impervious areas produce urban runoff that is directly connected to storm drains. This makes EIA a better predictor of actual runoff from urban catchments for hydraulic design of storm drain systems and modeling non-point source pollution. Compared to TIA, determining the EIA is considerably more difficult to calculate since it cannot be found by using remote sensing techniques, readily available EIA datasets, or aerial imagery interpretation alone. For this study, EIA percentages were calculated by two successive regression methods for five watersheds (with areas of 8.38 - 158mi2) located in Southern California using rainfall-runoff event data for the years 2004 - 2007. Runoff generated from the smaller storm events are considered to be emanating only from the effective impervious areas. Therefore, larger events that were considered to have runoff from both impervious and pervious surfaces were successively removed in the regression methods using a criterion of (1) 1mm and (2) a max (2 , 1mm) above the regression line. MSE is calculated from actual runoff and runoff predicted by the regression. Analysis of standard deviations showed that criterion of max (2 , 1mm) better fit the regression line and is the preferred method in predicting the EIA percentage. The estimated EIAs have shown to be approximately 78% to 43% of the TIA which shows use of EIA instead of TIA can have significant impact on the cost building urban hydraulic systems and stormwater capture devices.

  5. An improved model to predict bandwidth enhancement in an inductively tuned common source amplifier.

    PubMed

    Reza, Ashif; Misra, Anuraag; Das, Parnika

    2016-05-01

    This paper presents an improved model for the prediction of bandwidth enhancement factor (BWEF) in an inductively tuned common source amplifier. In this model, we have included the effect of drain-source channel resistance of field effect transistor along with load inductance and output capacitance on BWEF of the amplifier. A frequency domain analysis of the model is performed and a closed-form expression is derived for BWEF of the amplifier. A prototype common source amplifier is designed and tested. The BWEF of amplifier is obtained from the measured frequency response as a function of drain current and load inductance. In the present work, we have clearly demonstrated that inclusion of drain-source channel resistance in the proposed model helps to estimate the BWEF, which is accurate to less than 5% as compared to the measured results.

  6. Design of double gate vertical tunnel field effect transistor using HDB and its performance estimation

    NASA Astrophysics Data System (ADS)

    Seema; Chauhan, Sudakar Singh

    2018-05-01

    In this paper, we demonstrate the double gate vertical tunnel field-effect transistor using homo/hetero dielectric buried oxide (HDB) to obtain the optimized device characteristics. In this concern, the existence of double gate, HDB and electrode work-function engineering enhances DC performance and Analog/RF performance. The use of electrostatic doping helps to achieve higher on-current owing to occurrence of higher tunneling generation rate of charge carriers at the source/epitaxial interface. Further, lightly doped drain region and high- k dielectric below channel and drain region are responsible to suppress the ambipolar current. Simulated results clarifies that proposed device have achieved the tremendous performance in terms of driving current capability, steeper subthreshold slope (SS), drain induced barrier lowering (DIBL), hot carrier effects (HCEs) and high frequency parameters for better device reliability.

  7. Assessment of Asphalt Concrete Reinforcement Grid in Flexible Pavements

    DTIC Science & Technology

    2016-05-01

    Guide for the Design of Pavement Structures (1993) remains in use and describes in detail the accepted procedures for both the design and maintenance...of pavement structures. Design considerations include pavement perfor- mance, traffic, subgrade soil, construction materials, environment, drain- age...Association of State Highway and Transportation Officials). 1993. Guide for the Design of Pavement Structures. Washington, DC: American Association of

  8. 49 CFR 193.2173 - Water removal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Water removal. 193.2173 Section 193.2173...: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2173 Water removal. (a) Impoundment areas must be constructed such that all areas drain completely to prevent water collection. Drainage...

  9. 49 CFR 193.2173 - Water removal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Water removal. 193.2173 Section 193.2173...: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2173 Water removal. (a) Impoundment areas must be constructed such that all areas drain completely to prevent water collection. Drainage...

  10. 49 CFR 193.2173 - Water removal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Water removal. 193.2173 Section 193.2173...: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2173 Water removal. (a) Impoundment areas must be constructed such that all areas drain completely to prevent water collection. Drainage...

  11. 49 CFR 193.2173 - Water removal.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Water removal. 193.2173 Section 193.2173...: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2173 Water removal. (a) Impoundment areas must be constructed such that all areas drain completely to prevent water collection. Drainage...

  12. 49 CFR 193.2173 - Water removal.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Water removal. 193.2173 Section 193.2173...: FEDERAL SAFETY STANDARDS Design Impoundment Design and Capacity § 193.2173 Water removal. (a) Impoundment areas must be constructed such that all areas drain completely to prevent water collection. Drainage...

  13. Advances in electrometer vacuum tube design

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Single-ended, miniature-cathode tube with a relatively low grid current level is constructed. Adequate cathode temperature at relatively low heater power drain is provided by designing the supporting spacers to provide a square cathode hole. Method of assembling the mount and bonding the elements is discussed.

  14. Is a drain tube necessary for minimally invasive lumbar spine fusion surgery?

    PubMed

    Hung, Pei-I; Chang, Ming-Chau; Chou, Po-Hsin; Lin, Hsi-Hsien; Wang, Shih-Tien; Liu, Chien-Lin

    2017-03-01

    This study aimed to evaluate if closed suction wound drainage is necessary in minimally invasive surgery of transforaminal lumbar interbody fusion (MIS TLIF). This is a prospective randomized clinical study. Fifty-six patients who underwent MIS TLIF were randomly divided into groups A (with a closed suction wound drainage) and B (without tube drainage). Surgical duration, intraoperative blood loss, timing of ambulation, length of hospital stay and complications were recorded. Patients were followed up for an average of 25.3 months. Clinical outcome was assessed using the Oswestry disability index and visual analogue scale (VAS). Fusion rate was classified with the Bridwell grading system, based on plain radiograph. Both groups had similar patient demographics. The use of drains had no significant influence on perioperative parameters including operative time, estimated blood loss, length of stay and complications. Patients in group B started ambulation 1 day earlier than patients in group A (p < 0.001). Clinical outcomes were comparable between group A and group B. A drain tube can lead to pain, anxiety and discomfort during the postoperative period. We conclude that drain tubes are not necessary for MIS TLIF. Patients without drains had the benefit of earlier ambulation than those with drains.

  15. Right main bronchial fracture resolution by digital thoracic drainage system.

    PubMed

    Cortés Julián, Gildardo; Mier, José M; Iñiguez, Marco A; Guzmán de Alba, Enrique

    2016-03-01

    Tracheobronchial stenosis is common in the thoracic surgery service, and iatrogenic injury of the airway after manipulation is not infrequent. When a digital thoracic drainage system came onto the market, many advantages were evident. A 24-year-old woman with critical right main bronchial stenosis underwent airway dilation that was complicated by a tear with a massive air leak, resulting in a total right pneumothorax. We employed a pleural drain connected to a digital thoracic drainage system. The drain was removed 2 days after successful resolution of the air leak. © The Author(s) 2015.

  16. Acetic acid as a decontamination method for sink drains in a nosocomial outbreak of metallo-β-lactamase-producing Pseudomonas aeruginosa.

    PubMed

    Stjärne Aspelund, A; Sjöström, K; Olsson Liljequist, B; Mörgelin, M; Melander, E; Påhlman, L I

    2016-09-01

    Pseudomonas aeruginosa may colonize water systems via biofilm formation. In hospital environments, contaminated sinks have been associated with nosocomial transmission. Here we describe a prolonged outbreak of a metallo-β-lactamase-producing P. aeruginosa (Pae-MBL) associated with sink drains, and propose a previously unreported decontamination method with acetic acid. To describe a nosocomial outbreak of Pae-MBL associated with hospital sink drains and to evaluate acetic acid as a decontamination method. The outbreak was investigated by searching the microbiology database, microbiological sampling and strain typing. Antibacterial and antibiofilm properties of acetic acid were evaluated in vitro. Pae-MBL-positive sinks were treated with 24% acetic acid once weekly and monitored with repeated cultures. Fourteen patients with positive cultures for Pae-MBL were identified from 2008 to 2014. The patients had been admitted to three wards, where screening discovered Pae-MBL in 12 sink drains located in the patient bathrooms. Typing of clinical and sink drain isolates revealed identical or closely related strains. Pae-MBL biofilm was highly sensitive to acetic acid with a minimum biofilm eradication concentration of 0.75% (range: 0.19-1.5). Weekly treatment of colonized sink drains with acetic acid resulted in negative cultures and terminated transmission. Acetic acid is highly effective against Pae-MBL biofilms, and may be used as a simple method to decontaminate sink drains and to prevent nosocomial transmission. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Stainless Steel NaK Circuit Integration and Fill Submission

    NASA Technical Reports Server (NTRS)

    Garber, Anne E.

    2006-01-01

    The Early Flight Fission Test Facilities (EFF-TF) team has been tasked by the Marshall Space Flight Center Nuclear Systems Office to design, fabricate, and test an actively pumped alkali metal flow circuit. The system, which was originally designed to hold a eutectic mixture of sodium potassium (NaK), was redesigned to hold lithium; but due to a shift in focus, it is once again being prepared for use with NaK. Changes made to the actively pumped, high temperature loop include the replacement of the expansion reservoir, addition of remotely operated valves, and modification of the support table. Basic circuit components include: reactor segment, NaK to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and a spill reservoir. A 37-pin partial-array core (pin and flow path dimensions are the same as those in a full design) was selected for fabrication and test. This document summarizes the integration and fill of the pumped liquid metal NaK flow circuit.

  18. Runoff losses of sediment and phosphorus from no-till and cultivated soils receiving dairy manure.

    PubMed

    Verbree, David A; Duiker, Sjoerd W; Kleinman, Peter J A

    2010-01-01

    Managing manure in no-till systems is a water quality concern because surface application of manure can enrich runoff with dissolved phosphorus (P), and incorporation by tillage increases particulate P loss. This study compared runoff from well-drained and somewhat poorly drained soils under corn (Zea mays, L.) production that had been in no-till for more than 10 yr. Dairy cattle (Bos taurus L.) manure was broadcast into a fall planted cover crop before no-till corn planting or incorporated by chisel/disk tillage in the absence of a cover crop. Rainfall simulations (60 mm h(-1)) were performed after planting, mid-season, and post-harvest in 2007 and 2008. In both years and on both soils, no-till yielded significantly less sediment than did chisel/disking. Relative effects of tillage on runoff and P loss differed with soil. On the well-drained soil, runoff depths from no-till were much lower than with chisel/disking, producing significantly lower total P loads (22-50% less). On the somewhat poorly drained soil, there was little to no reduction in runoff depth with no-till, and total P loads were significantly greater than with chisel/disking (40-47% greater). Particulate P losses outweighed dissolved P losses as the major concern on the well-drained soil, whereas dissolved P from surface applied manure was more important on the somewhat poorly drained soil. This study confirms the benefit of no-till to erosion and total P runoff control on well-drained soils but highlights trade-offs in no-till management on somewhat poorly drained soils where the absence of manure incorporation can exacerbate total P losses.

  19. Carbon and Water Fluxes in a Drained Coastal Clearcut and a Pine Plantation in Eastern North Carolina

    Treesearch

    J. L. Deforest; Ge Sun; A. Noormets; J. Chen; Steve McNulty; M. Gavazzi; Devendra M. Amatya; R. W. Skaggs

    2006-01-01

    The effects of clear-cutting and cultivating for timber on ecosystem carbon and water fluxes were evaluated by comparative measurements of two drained coastal wetland systems in the North Carolina coastal plain. Measurements were conducted from January through September, 2005 in a recent clearcut (CC) of native hardwoods and a loblolly pine (Pinus tacda...

  20. No evidence for intercohort cannibalism in mixed-size cultures of food-size and fingerling hybrid catfish (channel catfish x blue catfish) grown in ponds in winter or summer

    USDA-ARS?s Scientific Manuscript database

    Hybrid catfish (' Channel Catfish Ictalurus punctatus X ' Blue Catfish I. furcatus) are normally harvested by seining single-batch pond production systems in fall or winter. Ponds are typically restocked without draining. There is concern that without completely draining the pond after harvest, food...

  1. Comparative and Developmental Anatomy of Cardiac Lymphatics

    PubMed Central

    Ratajska, A.; Gula, G.; Flaht-Zabost, A.; Czarnowska, E.; Ciszek, B.; Jankowska-Steifer, E.; Niderla-Bielinska, J.; Radomska-Lesniewska, D.

    2014-01-01

    The role of the cardiac lymphatic system has been recently appreciated since lymphatic disturbances take part in various heart pathologies. This review presents the current knowledge about normal anatomy and structure of lymphatics and their prenatal development for a better understanding of the proper functioning of this system in relation to coronary circulation. Lymphatics of the heart consist of terminal capillaries of various diameters, capillary plexuses that drain continuously subendocardial, myocardial, and subepicardial areas, and draining (collecting) vessels that lead the lymph out of the heart. There are interspecies differences in the distribution of lymphatic capillaries, especially near the valves, as well as differences in the routes and number of draining vessels. In some species, subendocardial areas contain fewer lymphatic capillaries as compared to subepicardial parts of the heart. In all species there is at least one collector vessel draining lymph from the subepicardial plexuses and running along the anterior interventricular septum under the left auricle and further along the pulmonary trunk outside the heart and terminating in the right venous angle. The second collector assumes a different route in various species. In most mammalian species the collectors run along major branches of coronary arteries, have valves and a discontinuous layer of smooth muscle cells. PMID:24592145

  2. Comparative and developmental anatomy of cardiac lymphatics.

    PubMed

    Ratajska, A; Gula, G; Flaht-Zabost, A; Czarnowska, E; Ciszek, B; Jankowska-Steifer, E; Niderla-Bielinska, J; Radomska-Lesniewska, D

    2014-01-01

    The role of the cardiac lymphatic system has been recently appreciated since lymphatic disturbances take part in various heart pathologies. This review presents the current knowledge about normal anatomy and structure of lymphatics and their prenatal development for a better understanding of the proper functioning of this system in relation to coronary circulation. Lymphatics of the heart consist of terminal capillaries of various diameters, capillary plexuses that drain continuously subendocardial, myocardial, and subepicardial areas, and draining (collecting) vessels that lead the lymph out of the heart. There are interspecies differences in the distribution of lymphatic capillaries, especially near the valves, as well as differences in the routes and number of draining vessels. In some species, subendocardial areas contain fewer lymphatic capillaries as compared to subepicardial parts of the heart. In all species there is at least one collector vessel draining lymph from the subepicardial plexuses and running along the anterior interventricular septum under the left auricle and further along the pulmonary trunk outside the heart and terminating in the right venous angle. The second collector assumes a different route in various species. In most mammalian species the collectors run along major branches of coronary arteries, have valves and a discontinuous layer of smooth muscle cells.

  3. Urban drainage control applying rational method and geographic information technologies

    NASA Astrophysics Data System (ADS)

    Aldalur, Beatriz; Campo, Alicia; Fernández, Sandra

    2013-09-01

    The objective of this study is to develop a method of controlling urban drainages in the town of Ingeniero White motivated by the problems arising as a result of floods, water logging and the combination of southeasterly and high tides. A Rational Method was applied to control urban watersheds and used tools of Geographic Information Technology (GIT). A Geographic Information System was developed on the basis of 28 panchromatic aerial photographs of 2005. They were georeferenced with control points measured with Global Positioning Systems (basin: 6 km2). Flow rates of basins and sub-basins were calculated and it was verified that the existing open channels have a low slope with the presence of permanent water and generate stagnation of water favored by the presence of trash. It is proposed for the output of storm drains, the use of an existing channel to evacuate the flow. The solution proposed in this work is complemented by the placement of three pumping stations: one on a channel to drain rain water which will allow the drain of the excess water from the lower area where is located the Ingeniero White city and the two others that will drain the excess liquid from the port area.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wegemar, B.

    Operating experiences from the Forsmark 3 and Oskarshamn 3 BWRs have been evaluated during the first two cycles of their operation. The objective of this work was to determine the influence on water chemistry quality and radiation field buildup from the special design characteristics of these plants. Important differences from older ASEA-ATOM BWRs include the concept of forward pumped high pressure heater drains, magnetic filtration of high pressure drains and use of more erosion-resistant materials in turbine components. Data obtained from water radiochemistry measurements, shutdown dose rates and gamma scanning surveys, fuel deposit analyses and occuptional exposure statistics have beenmore » used in order to enable a comparsion to older ASEA-ATOM BWRs. At the end of the second cycles, satisfactory feedwater quality was reported in both plants. Radiation levels around components in the primary systems are higher in Forsmark 3 and Oskarshamn 3 as compared to other plants. This is in agreement with reactor water activities, fuel deposits and gamma scanning surveys, indicating somewhat higher amounts of cobalt-60 and cobalt-58. However, in both plants occupational exposures were low during the first two years of operation.« less

  5. MAP Propulsion System Thermal Design

    NASA Technical Reports Server (NTRS)

    Mosier, Carol L.

    2003-01-01

    The propulsion system of the Microwave Anisotropy Probe (MAP) had stringent requirements that made the thermal design unique. To meet instrument stability requirements the system had to be designed to keep temperatures of all components within acceptable limits without heater cycling. Although the spacecraft remains at a fixed 22 sun angle at L2, the variations in solar constant, property degradation, and bus voltage range all significantly affect the temperature. Large portions of the fuel lines are external to the structure and all components are mounted to non-conductive composite structure. These two facts made the sensitivity to the MLI effective emissivity and bus temperature very high. Approximately two years prior to launch the propulsion system was redesigned to meet MAP requirements. The new design utilized hardware that was already installed in order to meet schedule constraints. The spacecraft design and the thermal requirements were changed to compensate for inadequacies of the existing hardware. The propulsion system consists of fuel lines, fill and drain lines/valve, eight thrusters, a HXCM, and a propulsion tank. A voltage regulator was added to keep critical components within limits. Software was developed to control the operational heaters. Trim resistors were put in series with each operational heater circuits and the tank survival heater. A highly sophisticated test program, which included real time model correlation, was developed to determine trim resistors sizes. These trim resistors were installed during a chamber break and verified during thermal balance testing.

  6. The contribution of rice agriculture to methylmercury in surface waters: A review of data from the Sacramento Valley, California

    USGS Publications Warehouse

    Tanner, K. Christy; Windham-Myers, Lisamarie; Fleck, Jacob; Tate, Kenneth W.; McCord, Stephen A.; Linquist, Bruce A.

    2017-01-01

    Methylmercury (MeHg) is a bioaccumulative pollutant produced in and exported from flooded soils, including those used for rice (Oriza sativa L.) production. Using unfiltered aqueous MeHg data from MeHg monitoring programs in the Sacramento River watershed from 1996 to 2007, we assessed the MeHg contribution from rice systems to the Sacramento River. Using a mixed-effects regression analysis, we compared MeHg concentrations in agricultural drainage water from rice-dominated regions (AgDrain) to MeHg concentrations in the Sacramento and Feather Rivers, both upstream and downstream of AgDrain inputs. We also calculated MeHg loads from AgDrains and the Sacramento and Feather Rivers. Seasonally, MeHg concentrations were higher during November through May than during June through October, but the differences varied by location. Relative to upstream, November through May AgDrain least-squares mean MeHg concentration (0.18 ng L−1, range 0.15–0.23 ng L−1) was 2.3-fold higher, while June through October AgDrain mean concentration (0.097 ng L−1, range 0.6–1.6 ng L−1) was not significantly different from upstream. June through October AgDrain MeHg loads contributed 10.7 to 14.8% of the total Sacramento River MeHg load. Missing flow data prevented calculation of the percent contribution of AgDrains in November through May. At sites where calculation was possible, November through May loads made up 70 to 90% of the total annual load. Elevated flow and MeHg concentration in November through May both contribute to the majority of the AgDrain MeHg load occurring during this period. Methylmercury reduction efforts should target elevated November through May MeHg concentrations in AgDrains. However, our findings suggest that the contribution and environmental impact of rice is an order of magnitude lower than previous studies in the California Yolo Bypass.

  7. Investigation using whole genome sequencing of a prolonged restaurant outbreak of Salmonella Typhimurium linked to the building drainage system, England, February 2015 to March 2016.

    PubMed

    Mair-Jenkins, John; Borges-Stewart, Roberta; Harbour, Caroline; Cox-Rogers, Judith; Dallman, Tim; Ashton, Philip; Johnston, Robert; Modha, Deborah; Monk, Philip; Puleston, Richard

    2017-12-01

    Following notification of a Salmonella enterica serovar Typhimurium gastroenteritis outbreak, we identified 82 cases linked to a restaurant with symptom onset from 12 February 2015 to 8 March 2016. Seventy-two cases had an isolate matching the nationally unique whole genome sequencing profile (single nucleotide polymorphism (SNP) address: 1.1.1.124.395.395). Interviews established exposure to the restaurant and subsequent case-control analysis identified an association with eating carvery buffet food (adjusted odds ratios (AOR): 20.9; 95% confidence interval (CI): 2.2 - ∞). Environmental inspections, food/water testing, and a food trace-back investigation were inconclusive. Repeated cycles of cleaning were undertaken, including hydrogen peroxide fogging, however, transmission continued. After 7 months of investigation, environmental swabbing identified 106 isolates from kitchen surfaces and restaurant drains matching the outbreak profile. We found structural faults with the drainage system and hypothesised that a reservoir of bacteria in drain biofilm and underfloor flooded areas may have sustained this outbreak. Ineffective drain water-traps (U-bends) may have also contributed by allowing transmission of contaminated aerosols into the kitchen environment. These findings suggest that routine swabbing of sink drain points and inspection of drainage systems should be considered in future outbreak scenarios.

  8. Investigation using whole genome sequencing of a prolonged restaurant outbreak of Salmonella Typhimurium linked to the building drainage system, England, February 2015 to March 2016

    PubMed Central

    Mair-Jenkins, John; Borges-Stewart, Roberta; Harbour, Caroline; Cox-Rogers, Judith; Dallman, Tim; Ashton, Philip; Johnston, Robert; Modha, Deborah; Monk, Philip; Puleston, Richard

    2017-01-01

    Following notification of a Salmonella enterica serovar Typhimurium gastroenteritis outbreak, we identified 82 cases linked to a restaurant with symptom onset from 12 February 2015 to 8 March 2016. Seventy-two cases had an isolate matching the nationally unique whole genome sequencing profile (single nucleotide polymorphism (SNP) address: 1.1.1.124.395.395). Interviews established exposure to the restaurant and subsequent case–control analysis identified an association with eating carvery buffet food (adjusted odds ratios (AOR): 20.9; 95% confidence interval (CI): 2.2 – ∞). Environmental inspections, food/water testing, and a food trace-back investigation were inconclusive. Repeated cycles of cleaning were undertaken, including hydrogen peroxide fogging, however, transmission continued. After 7 months of investigation, environmental swabbing identified 106 isolates from kitchen surfaces and restaurant drains matching the outbreak profile. We found structural faults with the drainage system and hypothesised that a reservoir of bacteria in drain biofilm and underfloor flooded areas may have sustained this outbreak. Ineffective drain water-traps (U-bends) may have also contributed by allowing transmission of contaminated aerosols into the kitchen environment. These findings suggest that routine swabbing of sink drain points and inspection of drainage systems should be considered in future outbreak scenarios. PMID:29233257

  9. Use of Subdural Evacuating Port System Following Open Craniotomy with Excision of Native Dura and Membranes for Management of Chronic Subdural Hematoma.

    PubMed

    Cage, Tene; Bach, Ashley; McDermott, Michael W

    2017-04-26

    An 86-year-old woman was admitted to the intensive care unit with a chronic subdural hematoma (CSDH) and rapid onset of worsening neurological symptoms. She was taken to the operating room for a mini-craniotomy for evacuation of the CSDH including excision of the dura and CSDH membrane. Postoperatively, a subdural evacuation port system (SEPS) was integrated into the craniotomy site and left in place rather than a traditional subdural catheter drain to evacuate the subdural space postoperatively. The patient had a good recovery and improvement of symptoms after evacuation and remained clinically well after the SEPS was removed. We offer the technique of dura and CSDH membrane excision plus SEPS drain as an effective postoperative alternative to the standard craniotomy leaving the native dura intact with traditional subdural drain that overlies the cortical surface of the brain in treating patients with CSDH.

  10. Design, Fabrication and Integration of a NaK-Cooled Circuit

    NASA Technical Reports Server (NTRS)

    Garber, Anne; Godfroy, Thomas

    2006-01-01

    The Early Flight Fission Test Facilities (EFF-TF) team has been tasked by the NASA Marshall Space Flight Center Nuclear Systems Office to design, fabricate, and test an actively pumped alkali metal flow circuit. The system, which was originally designed for use with a eutectic mixture of sodium potassium (NaK), was redesigned to for use with lithium. Due to a shi$ in focus, it is once again being prepared for use with NaK. Changes made to the actively pumped, high temperature circuit include the replacement of the expansion reservoir, addition of remotely operated valves, and modification of the support table. Basic circuit components include: reactor segment, NaK to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and a spill reservoir. A 37-pin partial-array core (pin and flow path dimensions are the same as those in a fill design) was selected for fabrication and test. This paper summarizes the integration and preparations for the fill of the pumped liquid metal NaK flow circuit.

  11. Study on effective MOSFET channel length extracted from gate capacitance

    NASA Astrophysics Data System (ADS)

    Tsuji, Katsuhiro; Terada, Kazuo; Fujisaka, Hisato

    2018-01-01

    The effective channel length (L GCM) of metal-oxide-semiconductor field-effect transistors (MOSFETs) is extracted from the gate capacitances of actual-size MOSFETs, which are measured by charge-injection-induced-error-free charge-based capacitance measurement (CIEF CBCM). To accurately evaluate the capacitances between the gate and the channel of test MOSFETs, the parasitic capacitances are removed by using test MOSFETs having various channel sizes and a source/drain reference device. A strong linear relationship between the gate-channel capacitance and the design channel length is obtained, from which L GCM is extracted. It is found that L GCM is slightly less than the effective channel length (L CRM) extracted from the measured MOSFET drain current. The reason for this is discussed, and it is found that the capacitance between the gate electrode and the source and drain regions affects this extraction.

  12. Characterization of water quality in selected tributaries of the Alamosa River, southwestern Colorado, including comparisons to instream water-quality standards and toxicological reference values, 1995-97

    USGS Publications Warehouse

    Ortiz, Roderick F.; Ferguson, Sheryl A.

    2001-01-01

    A comprehensive water-quality sampling network was implemented by the U.S. Geological Survey from 1995 through 1997 at 12 tributary sites to the Alamosa River. The network was designed to address data gaps identified in the initial ecological risk assessment of the Summitville Superfund site. Tributaries draining hydrothermally altered areas had higher median values for nearly all measured properties and constituents than tributaries draining unaltered areas. Colorado instream standards for pH, copper, iron, and zinc were in attainment at most tributary sites. Instream standards for pH and chronic aquatic-life standards for iron were not attained in Jasper Creek. Toxicological reference values were most often exceeded at Iron Creek, Alum Creek, Bitter Creek, Wightman Fork, and Burnt Creek. These tributaries all drain hydrothermally altered areas.

  13. Numerical simulation of offset-drain amorphous oxide-based thin-film transistors

    NASA Astrophysics Data System (ADS)

    Jeong, Jaewook

    2016-11-01

    In this study, we analyzed the electrical characteristics of amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors (TFTs) with an offset-drain structure by technology computer aided design (TCAD) simulation. When operating in a linear region, an enhancement-type TFT shows poor field-effect mobility because most conduction electrons are trapped in acceptor-like defects in an offset region when the offset length (L off) exceeds 0.5 µm, whereas a depletion-type TFT shows superior field-effect mobility owing to the high free electron density in the offset region compared with the trapped electron density. When operating in the saturation region, both types of TFTs show good field-effect mobility comparable to that of a reference TFT with a large gate overlap. The underlying physics of the depletion and enhancement types of offset-drain TFTs are systematically analyzed.

  14. Impact of random discrete dopant in extension induced fluctuation in gate-source/drain underlap FinFET

    NASA Astrophysics Data System (ADS)

    Wang, Yijiao; Huang, Peng; Xin, Zheng; Zeng, Lang; Liu, Xiaoyan; Du, Gang; Kang, Jinfeng

    2014-01-01

    In this work, three dimensional technology computer-aided design (TCAD) simulations are performed to investigate the impact of random discrete dopant (RDD) including extension induced fluctuation in 14 nm silicon-on-insulator (SOI) gate-source/drain (G-S/D) underlap fin field effect transistor (FinFET). To fully understand the RDD impact in extension, RDD effect is evaluated in channel and extension separately and together. The statistical variability of FinFET performance parameters including threshold voltage (Vth), subthreshold slope (SS), drain induced barrier lowering (DIBL), drive current (Ion), and leakage current (Ioff) are analyzed. The results indicate that RDD in extension can lead to substantial variability, especially for SS, DIBL, and Ion and should be taken into account together with that in channel to get an accurate estimation on RDF. Meanwhile, higher doping concentration of extension region is suggested from the perspective of overall variability control.

  15. Induction melter apparatus

    DOEpatents

    Roach, Jay A [Idaho Falls, ID; Richardson, John G [Idaho Falls, ID; Raivo, Brian D [Idaho Falls, ID; Soelberg, Nicholas R [Idaho Falls, ID

    2008-06-17

    Apparatus and methods of operation are provided for a cold-crucible-induction melter for vitrifying waste wherein a single induction power supply may be used to effect a selected thermal distribution by independently energizing at least two inductors. Also, a bottom drain assembly may be heated by an inductor and may include an electrically resistive heater. The bottom drain assembly may be cooled to solidify molten material passing therethrough to prevent discharge of molten material therefrom. Configurations are provided wherein the induction flux skin depth substantially corresponds with the central longitudinal axis of the crucible. Further, the drain tube may be positioned within the induction flux skin depth in relation to material within the crucible or may be substantially aligned with a direction of flow of molten material within the crucible. An improved head design including four shells forming thermal radiation shields and at least two gas-cooled plenums is also disclosed.

  16. Operating an induction melter apparatus

    DOEpatents

    Roach, Jay A.; Richardson, John G.; Raivo, Brian D.; Soelberg, Nicholas R.

    2006-01-31

    Apparatus and methods of operation are provided for a cold-crucible-induction melter for vitrifying waste wherein a single induction power supply may be used to effect a selected thermal distribution by independently energizing at least two inductors. Also, a bottom drain assembly may be heated by an inductor and may include an electrically resistive heater. The bottom drain assembly may be cooled to solidify molten material passing therethrough to prevent discharge of molten material therefrom. Configurations are provided wherein the induction flux skin depth substantially corresponds with the central longitudinal axis of the crucible. Further, the drain tube may be positioned within the induction flux skin depth in relation to material within the crucible or may be substantially aligned with a direction of flow of molten material within the crucible. An improved head design including four shells forming thermal radiation shields and at least two gas-cooled plenums is also disclosed.

  17. Emerging organic contaminants in vertical subsurface flow constructed wetlands: influence of media size, loading frequency and use of active aeration.

    PubMed

    Avila, Cristina; Nivala, Jaime; Olsson, Linda; Kassa, Kinfe; Headley, Tom; Mueller, Roland A; Bayona, Josep Maria; García, Joan

    2014-10-01

    Four side-by-side pilot-scale vertical flow (VF) constructed wetlands of different designs were evaluated for the removal of eight widely used emerging organic contaminants from municipal wastewater (i.e. ibuprofen, acetaminophen, diclofenac, tonalide, oxybenzone, triclosan, ethinylestradiol, bisphenol A). Three of the systems were free-draining, with one containing a gravel substrate (VGp), while the other two contained sand substrate (VS1p and VS2p). The fourth system had a saturated gravel substrate and active aeration supplied across the bottom of the bed (VAp). All beds were pulse-loaded on an hourly basis, except VS2p, which was pulse-loaded every 2h. Each system had a surface area of 6.2m(2), received a hydraulic loading rate of 95 mm/day and was planted with Phragmites australis. The beds received an organic loading rate of 7-16 gTOC/m(2)d. The sand-based VF (VS1p) performed significantly better (p<0.05) than the gravel-based wetland (VGp) both in the removal of conventional water quality parameters (TSS, TOC, NH4-N) and studied emerging organic contaminants except for diclofenac (85 ± 17% vs. 74 ± 15% average emerging organic contaminant removal for VS1p and VGp, respectively). Although loading frequency (hourly vs. bi-hourly) was not observed to affect the removal efficiency of the cited conventional water quality parameters, significantly lower removal efficiencies were found for tonalide and bisphenol A for the VF wetland that received bi-hourly dosing (VS2p) (higher volume per pulse), probably due to the more reducing conditions observed in that system. However, diclofenac was the only contaminant showing an opposite trend to the rest of the compounds, achieving higher elimination rates in the wetlands that exhibited less-oxidizing conditions (VS2p and VGp). The use of active aeration in the saturated gravel bed (VAp) generally improved the treatment performance compared to the free-draining gravel bed (VGp) and achieved a similar performance to the free-draining sand-based VF wetlands (VS1p). Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Implants for draining neovascular glaucoma.

    PubMed Central

    Molteno, A C; Van Rooyen, M M; Bartholomew, R S

    1977-01-01

    The implant design, surgical technique, and pharmacological methods of controlling bleb fibrosis, used to treat neovascular glaucoma, are described, together with the results of 14 operations performed on 12 eyes. Images PMID:843508

  19. The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu; Brinkmann, Debra H.; Ward, Shelly B.

    2013-03-15

    Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the secondmore » (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.« less

  20. The addition of SPECT/CT lymphoscintigraphy to breast cancer radiation planning spares lymph nodes critical for arm drainage.

    PubMed

    Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A

    2013-03-15

    This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. A new assessment method of pHEMT models by comparing relative errors of drain current and its derivatives up to the third order

    NASA Astrophysics Data System (ADS)

    Dobeš, Josef; Grábner, Martin; Puričer, Pavel; Vejražka, František; Míchal, Jan; Popp, Jakub

    2017-05-01

    Nowadays, there exist relatively precise pHEMT models available for computer-aided design, and they are frequently compared to each other. However, such comparisons are mostly based on absolute errors of drain-current equations and their derivatives. In the paper, a novel method is suggested based on relative root-mean-square errors of both drain current and its derivatives up to the third order. Moreover, the relative errors are subsequently relativized to the best model in each category to further clarify obtained accuracies of both drain current and its derivatives. Furthermore, one our older and two newly suggested models are also included in comparison with the traditionally precise Ahmed, TOM-2 and Materka ones. The assessment is performed using measured characteristics of a pHEMT operating up to 110 GHz. Finally, a usability of the proposed models including the higher-order derivatives is illustrated using s-parameters analysis and measurement at more operating points as well as computation and measurement of IP3 points of a low-noise amplifier of a multi-constellation satellite navigation receiver with ATF-54143 pHEMT.

  2. Data on Streamflow and Quality of Water and Bottom Sediment in and near Humboldt Wildlife Management Area, Churchill and Pershing Counties, Nevada, 1998-2000

    USGS Publications Warehouse

    Paul, Angela P.; Thodal, Carl E.

    2003-01-01

    This study was initiated to expand upon previous findings that indicated concentrations of dissolved solids, arsenic, boron, mercury, molybdenum, selenium, and uranium were either above geochemical background concentrations or were approaching or exceeding ecological criteria in the lower Humboldt River system. Data were collected from May 1998 to September 2000 to further characterize streamflow and surface-water and bottom-sediment quality in the lower Humboldt River, selected agricultural drains, Upper Humboldt Lake, and Lower Humboldt Drain (ephemeral outflow from Humboldt Sink). During this study, flow in the lower Humboldt River was either at or above average. Flows in Army and Toulon Drains generally were higher than reported in previous investigations. An unnamed agricultural drain contributed a small amount to the flow measured in Army Drain. In general, measured concentrations of sodium, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium were higher in water from agricultural drains than in Humboldt River water during this study. Mercury concentrations in water samples collected during the study period typically were below the laboratory reporting level. However, low-level mercury analyses showed that samples collected in August 1999 from Army Drain had higher mercury concentrations than those collected from the river or Toulon Drain or the Lower Humboldt Drain. Ecological criteria and effect concentrations for sodium, chloride, dissolved solids, arsenic, boron, mercury, and molybdenum were exceeded in some water samples collected as part of this study. Although water samples from the agricultural drains typically contained higher concentrations of sodium, chloride, dissolved solids, arsenic, boron, and uranium, greater instantaneous loads of these constituents were carried in the river near Lovelock than in agricultural drains during periods of high flow or non-irrigation. During this study, the high flows in the lower Humboldt River produced the maximum instantaneous loads of sodium, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium at all river-sampling sites, except molybdenum near Imlay. Nevada Division of Environmental Protection monitoring reports on mine-dewatering discharge for permitted releases of treated effluent to the surface waters of the Humboldt River and its tributaries were reviewed for reported discharges and trace-element concentrations from June 1998 to September 1999. These data were compared with similar information for the river near Imlay. In all bottom sediments collected for this study, arsenic concentrations exceeded the Canadian Freshwater Interim Sediment-Quality Guideline for the protection of aquatic life and probable-effect level (concentration). Sediments collected near Imlay, Rye Patch Reservoir, Lovelock, and from Toulon Drain and Army Drain were found to contain cadmium and chromium concentrations that exceeded Canadian criteria. Chromium concentrations in sediments collected from these sites also exceeded the consensus-based threshold-effect concentration. The Canadian criterion for sediment copper concentration was exceeded in sediments collected from the Humboldt River near Lovelock and from Toulon, Army, and the unnamed agricultural drains. Mercury in sediments collected near Imlay and from Toulon Drain in August 1999 exceeded the U.S. Department of the Interior sediment probable-effect level. Nickel concentrations in sediments collected during this study were above the consensus-based threshold-effect concentration. All other river and drain sediments had constituent concentrations below protective criteria and toxicity thresholds. In Upper Humboldt Lake, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium concentrations in surface-water samples collected near the mouth of the Humboldt River generally were higher than in samples collected near the mouth of Army Drain. Ecological criteria or effect con

  3. Comparative analysis of the outflow water quality of two sustainable linear drainage systems.

    PubMed

    Andrés-Valeri, V C; Castro-Fresno, D; Sañudo-Fontaneda, L A; Rodriguez-Hernandez, J

    2014-01-01

    Three different drainage systems were built in a roadside car park located on the outskirts of Oviedo (Spain): two sustainable urban drainage systems (SUDS), a swale and a filter drain; and one conventional drainage system, a concrete ditch, which is representative of the most frequently used roadside drainage system in Spain. The concentrations of pollutants were analyzed in the outflow of all three systems in order to compare their capacity to improve water quality. Physicochemical water quality parameters such as dissolved oxygen, total suspended solids, pH, electrical conductivity, turbidity and total petroleum hydrocarbons were monitored and analyzed for 25 months. Results are presented in detail showing significantly smaller amounts of outflow pollutants in SUDS than in conventional drainage systems, especially in the filter drain which provided the best performance.

  4. Multiyear nutrient removal performance of three constructed wetlands intercepting tile drain flows from grazed pastures.

    PubMed

    Tanner, Chris C; Sukias, James P S

    2011-01-01

    Subsurface tile drain flows can be a major s ource of nurient loss from agricultural landscapes. This study quantifies flows and nitrogen and phosphorus yields from tile drains at three intensively grazed dairy pasture sites over 3- to 5-yr periods and evaluates the capacity of constructed wetlands occupying 0.66 to 1.6% of the drained catchments too reduce nutrient loads. Continuous flow records are combined with automated flow-proportional sampling of nutrient concentrations to calculate tile drain nutrient yields and wetland mass removal rates. Annual drainage water yields rangedfrom 193 to 564 mm (16-51% of rainfall) at two rain-fed sites and from 827 to 853 mm (43-51% of rainfall + irrigation) at an irrigated site. Annually, the tile drains exported 14 to 109 kg ha(-1) of total N (TN), of which 58 to 90% was nitrate-N. Constructed wetlands intercepting these flows removed 30 to 369 gTN m(-2) (7-63%) of influent loadings annually. Seasonal percentage nitrate-N and TN removal were negatively associated with wetland N mass loadings. Wetland P removal was poor in all wetlands, with 12 to 115% more total P exported annually overall than received. Annually, the tile drains exported 0.12 to 1.38 kg ha of total P, of which 15 to 93% was dissolved reactive P. Additional measures are required to reduce these losses or provide supplementary P removal. Wetland N removal performance could be improved by modifying drainage systems to release flows more gradually and improving irrigation practices to reduce drainage losses.

  5. Special Component Designs for Differential-Amplifier MMICs

    NASA Technical Reports Server (NTRS)

    Kangaslahti, Pekka

    2010-01-01

    Special designs of two types of electronic components transistors and transmission lines have been conceived to optimize the performances of these components as parts of waveguide-embedded differential-amplifier monolithic microwave integrated circuits (MMICs) of the type described in the immediately preceding article. These designs address the following two issues, the combination of which is unique to these particular MMICs: Each MMIC includes a differential double-strip transmission line that typically has an impedance between 60 and 100 W. However, for purposes of matching of impedances, transmission lines having lower impedances are also needed. The transistors in each MMIC are, more specifically, one or more pair(s) of InP-based high-electron-mobility transistors (HEMTs). Heretofore, it has been common practice to fabricate each such pair as a single device configured in the side-to-side electrode sequence source/gate/drain/gate/source. This configuration enables low-inductance source grounding from the sides of the device. However, this configuration is not suitable for differential operation, in which it is necessary to drive the gates differentially and to feed the output from the drain electrodes differentially. The special transmission-line design provides for three conductors, instead of two, in places where lower impedance is needed. The third conductor is a metal strip placed underneath the differential double-strip transmission line. The third conductor increases the capacitance per unit length of the transmission line by such an amount as to reduce the impedance to between 5 and 15 W. In the special HEMT-pair design, the side-to-side electrode sequence is changed to drain/gate/source/gate/ drain. In addition, the size of the source is reduced significantly, relative to corresponding sizes in prior designs. This reduction is justified by the fact that, by virtue of the differential configuration, the device has an internal virtual ground, and therefore there is no need for a low-resistance contact between the source and the radio-frequency circuitry. The source contact is needed only for DC biasing. These designs were implemented in a single-stage-amplifier MMIC. In a test at a frequency of 305 GHz, the amplifier embedded in a waveguide exhibited a gain of 0 dB; after correcting for the loss in the waveguide, the amplifier was found to afford a gain of 0.9 dB. In a test at 220 GHz, the overall gain of the amplifier- and-waveguide assembly was found to be 3.5 dB.

  6. Randomized Controlled Trial to Reduce Bacterial Colonization of Surgical Drains After Breast and Axillary Operations

    PubMed Central

    Degnim, Amy C.; Scow, Jeffrey S.; Hoskin, Tanya L.; Miller, Joyce P.; Loprinzi, Margie; Boughey, Judy C.; Jakub, James W.; Throckmorton, Alyssa; Patel, Robin; Baddour, Larry M.

    2014-01-01

    Objective To determine if bacterial colonization of drains can be reduced by local antiseptic interventions. Summary Background Drains are a potential source of bacterial entry into surgical wounds and may contribute to surgical site infection (SSI) after breast surgery. Methods Following IRB approval, patients undergoing total mastectomy and/or axillary lymph node dissection were randomized to standard drain care (control) or drain antisepsis (treated). Standard drain care comprised twice daily cleansing with alcohol swabs. Antisepsis drain care included 1) a chlorhexidine disc at the drain exit site and 2) irrigation of the drain bulb twice daily with dilute sodium hypochlorite (Dakin’s) solution. Cultures results of drain fluid and tubing were compared between control and antisepsis groups. Results Overall, 100 patients with 125 drains completed the study with 48 patients (58 drains) in the control group and 52 patients (67 drains) in the antisepsis group. Cultures of drain bulb fluid at one week were positive (1+ or greater growth) in 66% (38/58) of control drains compared to 21% of antisepsis drains (14/67), (p=0.0001). Drain tubing cultures demonstrated >50 CFU in 19% (8/43) of control drains versus 0% (0/53) of treated drains (p=0.004). SSI was diagnosed in 6 patients (6%) - 5 patients in the control group and 1 patient in the antisepsis group (p=0.06). Conclusions Simple and inexpensive local antiseptic interventions with a chlorhexidine disc and hypochlorite solution reduce bacterial colonization of drains. Based on these data, further study of drain antisepsis and its potential impact on SSI rate is warranted. PMID:23518704

  7. Los Angeles Area Permit Holder Estimated Trash Load Reduction

    EPA Pesticide Factsheets

    The Los Angeles River has been designated as an impaired waterbody due to the large volume of trash it receives from the watershed. To address this problem a Total Maximum Daily Load (TMDL), which establishes baseline trash loads to the river from the watershed, has been incorporated into the area stormwater permit. The permit requires each permittee to implement trash reduction measures for discharges through the storm drain system with an emphasis on the installation of full capture devices. The stormwater permit incorporates progressive reductions in trash discharges to the Los Angeles River, reaching a zero level in 2016.

  8. Adaptation Options for Land Drainage Systems Towards Sustainable Agriculture and Environment: A Czech Perspective

    NASA Astrophysics Data System (ADS)

    Kulhavý, Zbyněk; Fučík, Petr

    2015-04-01

    In this paper, issues of agricultural drainage systems are introduced and discussed from the views of their former, current and future roles and functioning in the Czech Republic (CR). A methodologically disparate survey was done on thirty-nine model localities in CR with different intensity and state of land drainage systems, aimed at description of commonly occurred problems and possible adaptations of agricultural drainage as perceived by farmers, land owners, landscape managers or by protective water management. The survey was focused on technical state of drainage, fragmentation of land ownership within drained areas as well as on possible conflicts between agricultural and environmental interests in a landscape. Achieved results confirmed that there is obviously an increasing need to reassess some functions of prevailingly single-purpose agricultural drainage systems. Drainage intensity and detected unfavourable technical state of drainage systems as well as the risks connected with the anticipated climate change from the view of possible water scarcity claims for a complex solution. An array of adaptation options for agricultural drainage systems is presented, aiming at enhancement of water retention time and improvement of water quality. It encompasses additional flow-controlling measures on tiles or ditches, or facilities for making selected parts of a drainage system inoperable in order to retain or slow down the drainage runoff, to establish water accumulation zones and to enhance water self-cleaning processes. However, it was revealed that the question of landowner parcels fragmentation on drained land in CR would dramatically complicate design and realization of these measures. Presented solutions and findings are propounded with a respect to contemporary and future state policies and international strategies for sustainable agriculture, water management and environment.

  9. Severe bradycardia and hypotension after connecting negative pressure to the subgaleal drain during craniotomy closure.

    PubMed

    Karamchandani, K; Chouhan, R S; Bithal, P K; Dash, H H

    2006-05-01

    Negative pressure drainage systems are often used after craniotomy for evacuation of potential bleeding. There are several reports of haemodynamic disturbances with epidural negative pressure drainage, but such reports are very few for subgaleal drains placed over the bone flap. We report a case in which a patient developed severe cardiovascular disturbances after the vacuum drainage was connected to a subgaleal drain after craniotomy for aneurysm clipping. The patient had no significant cardiac history, had an uneventful intra-operative course and yet developed bradycardia and hypotension, which were reproducible and severe enough to require atropine administration. Anaesthetists must be aware of these effects, so that they can anticipate and treat such complications.

  10. Storm drains are sources of human fecal pollution during dry weather in three urban southern California watersheds.

    PubMed

    Sercu, Bram; Van De Werfhorst, Laurie C; Murray, Jill; Holden, Patricia A

    2009-01-15

    Coastal urbanized areas in Southern California experience frequent beach water quality warnings in summer due to high concentrations of fecal indicator bacteria (FIB). Remediation can be difficult, as sources are often unknown. During two summers, we sampled three urbanized watersheds in Santa Barbara, CA at sites with historically high FIB concentrations to determine if human fecal matter was influencing water quality. By quantification of a human-specific Bacteroides marker (HBM), human waste was evidenced throughout both transects, and concentrations were highest in the discharges of several flowing storm drains. The HBM concentrations in storm drain discharges varied by up to 5 orders of magnitude on the same day. While the exact points of entry into the storm drain systems were not definitively determined, further inspection of the drain infrastructure suggested exfiltrating sanitary sewers as possible sources. The HBM and FIB concentrations were not consistently correlated, although the exclusive occurrence of high HBM concentrations with high FIB concentrations warrants the use of FIB analyses for a first tier of sampling. The association of human fecal pollution with dry weather drainage could be a window into a larger problem for other urbanized coastal areas with Mediterranean-type climates.

  11. Groundwater hydrology and estimation of horizontal groundwater flux from the Rio Grande at selected locations in Albuquerque, New Mexico, 2009–10

    USGS Publications Warehouse

    Rankin, Dale R.; Oelsner, Gretchen P.; McCoy, Kurt J.; Goeff J.M. Moret,; Jeffery A. Worthington,; Kimberly M. Bandy-Baldwin,

    2016-03-17

    The Albuquerque area of New Mexico has two principal sources of water: (1) groundwater from the Santa Fe Group aquifer system, and (2) surface water from the Rio Grande. From 1960 to 2002, pumping from the Santa Fe Group aquifer system caused groundwater levels to decline more than 120 feet while water-level declines along the Rio Grande in Albuquerque were generally less than 40 feet. These differences in water-level declines in the Albuquerque area have resulted in a great deal of interest in quantifying the river-aquifer interaction associated with the Rio Grande.In 2003, the U.S. Geological Survey, in cooperation with the Bureau of Reclamation, acting as fiscal agent for the Middle Rio Grande Endangered Species Collaborative Program, and the U.S. Army Corps of Engineers, began a study to characterize the hydrogeology of the Rio Grande inner valley alluvial aquifer in the Albuquerque area of New Mexico. The study provides hydrologic data in order to enhance the understanding of rates of water leakage from the Rio Grande to the alluvial aquifer, groundwater flow through the aquifer, and discharge of water from the aquifer to riverside drains. The study area extends about 20 miles along the Rio Grande in the Albuquerque area. Piezometers and surface-water gages were installed in paired transects at eight locations. Nested piezometers, completed at various depths in the alluvial aquifer, and surface-water gages, installed in the Rio Grande and riverside drains, were instrumented with pressure transducers. Water-level and water-temperature data were collected from 2009 to 2010.Water levels from the piezometers indicated that groundwater movement was usually away from the river towards the riverside drains. Annual mean horizontal groundwater gradients in the inner valley alluvial aquifer ranged from 0.0024 (I-25 East) to 0.0144 (Pajarito East). The median hydraulic conductivity values of the inner valley alluvial aquifer, determined from slug tests, ranged from 30 feet per day (ft/d) (Montaño) to 120 ft/d (Central) for paired transects, with a median hydraulic conductivity for all transects of 50 ft/d. Daily mean groundwater fluxes from the river through the inner valley alluvial aquifer computed using Darcy’s Law and the slug test results ranged from about 0.01 ft/d (Montaño West) to between 1.0 and 2.0 ft/d (Central East). Median annual groundwater fluxes from the river through the inner valley alluvial aquifer determined using the Suzuki-Stallman method was greatest at Alameda East (0.50 ft/d) and lowest at Alameda West (0.25 ft/d). The results from both methods agreed reasonably well.Seepage investigations conducted by measuring discharge in the east and west riverside drains provided information for computing changes in flow within the drains and for evaluating results from Darcy’s Law and Suzuki-Stallman method flux calculations. Discharge measured in the east riverside drain between the Barelas Bridge and the I-25 bridge indicated that the flow in the east riverside drain increased by an average of 56.5 cubic feet per day per linear foot (ft3/d/ft) of drain. Discharge measured in the west riverside drain between the Central bridge and the I-25 bridge indicated that flow increased between west drain miles 0 and 4, an average of 53.8 ft3/d/ft of drain, and that flow increased between west drain miles 7 and 10, an average of 44.9 ft3/d/ft of drain. In comparison to the seepage measurement results, the groundwater fluxes from the river through the inner valley alluvial aquifer calculated from Darcy’s Law (qslug) and by the Suzuki-Stallman method (qheat) would account for 20–36 percent or 53–95 percent, respectively, of the total flow in the east riverside drain and 22–31 percent or 19–26 percent, respectively, of the total flow in the west drain. These results indicate that the drains likely also receive water from outside the inner valley.The spatial variability of horizontal hydraulic gradients and groundwater fluxes can be primarily attributed to variability in the distances between the river and riverside drains throughout the study area and geologic heterogeneities in the alluvial aquifer. Temporal variability in the water levels, which control the horizontal hydraulic gradients and fluxes between the Rio Grande and the riverside drains, can be primarily attributed to seasonal fluctuations in river stage and irrigation practices.

  12. Effects of tillage and application rate on atrazine transport to subsurface drainage: Evaluation of RZWQM using a six-year field study

    USGS Publications Warehouse

    Malone, Robert W.; Nolan, Bernard T.; Ma, Liwang; Kanwar, Rameshwar S.; Pederson, Carl H.; Heilman, Philip

    2014-01-01

    Well tested agricultural system models can improve our understanding of the water quality effects of management practices under different conditions. The Root Zone Water Quality Model (RZWQM) has been tested under a variety of conditions. However, the current model's ability to simulate pesticide transport to subsurface drain flow over a long term period under different tillage systems and application rates is not clear. Therefore, we calibrated and tested RZWQM using six years of data from Nashua, Iowa. In this experiment, atrazine was spring applied at 2.8 (1990–1992) and 0.6 kg/ha/yr (1993–1995) to two 0.4 ha plots with different tillage (till and no-till). The observed and simulated average annual flow weighted atrazine concentrations (FWAC) in subsurface drain flow from the no-till plot were 3.7 and 3.2 μg/L, respectively for the period with high atrazine application rates, and 0.8 and 0.9 μg/L, respectively for the period with low application rates. The 1990–1992 observed average annual FWAC difference between the no-till and tilled plot was 2.4 μg/L while the simulated difference was 2.1 μg/L. These observed and simulated differences for 1993–1995 were 0.1 and 0.1 μg/L, respectively. The Nash–Sutcliffe model performance statistic (EF) for cumulative atrazine flux to subsurface drain flow was 0.93 for the no-till plot testing years (1993–1995), which is comparable to other recent model tests. The value of EF is 1.0 when simulated data perfectly match observed data. The order of selected parameter sensitivity for RZWQM simulated FWAC was atrazine partition coefficient > number of macropores > atrazine half life in soil > soil hydraulic conductivity. Simulations from 1990 to 1995 with four different atrazine application rates applied at a constant rate throughout the simulation period showed concentrations in drain flow for the no-till plot to be twice those of the tilled plot. The differences were more pronounced in the early simulation period (1990–1992), partly because of the characteristics of macropore flow during large storms. The results suggest that RZWQM is a promising tool to study pesticide transport to subsurface drain flow under different tillage systems and application rates over several years, the concentrations of atrazine in drain flow can be higher with no-till than tilled soil over a range of atrazine application rates, and atrazine concentrations in drain flow are sensitive to the macropore flow characteristics under different tillage systems and rainfall timing and intensity.

  13. The use of a portable digital thoracic suction Thopaz drainage system for the management of a persistent spontaneous secondary pneumothorax in a patient with underlying interstitial lung disease

    PubMed Central

    Jenkins, William S A; Hall, David P; Dhaliwal, Kev; Hill, Adam T; Hirani, Nik

    2012-01-01

    We present the case of a 68-year-old woman who presented in extremis with a secondary pneumothorax with a past history of severe idiopathic pulmonary fibrosis. Following insertion of a 32F intercostal drain, she developed a persistent broncho-pleural fistula and became dependent on negative-pressure wall-mounted suction to prevent respiratory compromise. She declined definitive surgical intervention and was therefore managed conservatively. After adhering to the wall-mounted suction method for 49 days, we obtained for use a portable digital thoracic drainage system previously used only in the cardiothoracic postoperative patient. This electronically delivered, negative-pressure drainage system induced radiographic improvement within 24 h, and allowed the patient to mobilise for the first time since admission. The patient was discharged home with the Thopaz drain in situ 8 weeks after placing it, and the drain was removed successfully with a resolved pneumothorax 20 weeks  after her initial presentation. PMID:22684832

  14. Moss and soil contributions to the annual net carbon flux of a maturing boreal forest

    USGS Publications Warehouse

    Harden, J.W.; O'Neill, K. P.; Trumbore, S.E.; Veldhuis, H.; Stocks, B.J.

    1997-01-01

    We used input and decomposition data from 14C studies of soils to determine rates of vertical accumulation of moss combined with carbon storage inventories on a sequence of burns to model how carbon accumulates in soils and moss after a stand-killing fire. We used soil drainage - moss associations and soil drainage maps of the old black spruce (OBS) site at the BOREAS northern study area (NSA) to areally weight the contributions of each moderately well drained, feathermoss areas; poorly drained sphagnum - feathermoss areas; and very poorly drained brown moss areas to the carbon storage and flux at the OBS NSA site. On this very old (117 years) complex of black spruce, sphagnum bog veneer, and fen systems we conclude that these systems are likely sequestering 0.01-0.03 kg C m-2 yr-' at OBS-NSA today. Soil drainage in boreal forests near Thompson, Manitoba, controls carbon storage and flux by controlling moss input and decomposition rates and by controlling through fire the amount and quality of carbon left after burning. On poorly drained soils rich in sphagnum moss, net accumulation and long-term storage of carbon is higher than on better drained soils colonized by feathermosses. The carbon flux of these contrasting ecosystems is best characterized by soil drainage class and stand age, where stands recently burned are net sources of CO2, and maturing stands become increasingly stronger sinks of atmospheric CO2. This approach to measuring carbon storage and flux presents a method of scaling to larger areas using soil drainage, moss cover, and stand age information.

  15. Using Arc/Info GIS to help implement the National Pollutant Discharge Elimination System (NPDES) stormwater permit for Los Angeles County

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levine, D.A.; Pace, P.J.; Woods, J.A.

    1997-06-01

    One of Los Angeles County Department of Public Works` many responsibilities is to manage non-point pollution that enters the storm drain network within Los Angeles County. The management of this non-point source pollution is mandated by the NPDES guidelines under the Federal Clean Water Act. These guidelines require the County to monitor the drainage network and the storm water and urban runoff flowing through it. The County covers over 3,117 square miles, with the NPDES Permit covering over 3,100 square miles and over 2500 miles of storm drains. A proposed solution to monitor and manage this vast geographic area ismore » centered upon an Arc/Info GIS. Some of the many concerns which need to be addressed include the administration and evaluation of Best Management Practices (BMP`s), storm drain inspection for illegal connections and illicit discharges, and pollutant load assessment and modeling. The storm drain network and other coverages will be related to external data bases currently used for facility management and planning. This system would be used for query purposes to perform spatial modeling and {open_quotes}what if{close_quotes} scenarios needed to create maps and reports required by the permit and to evaluate various BMP implementation strategies.« less

  16. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety.

    PubMed

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.

  17. An overview of impact of subsurface drainage project studies on salinity management in developing countries

    NASA Astrophysics Data System (ADS)

    Tiwari, Priyanka; Goel, Arun

    2017-05-01

    Subsurface drainage has been used for more than a century to keep water table at a desired level of salinity and waterlogging control. This paper has been focused on the impact assessment of pilot studies in India and some other countries from 1969 to 2014 . This review article may prove quite useful in deciding the installation of subsurface drainage project depending on main design parameters, such as drain depth and drain spacing, installation area and type of used outlet. A number of pilot studies have been taken up in past to solve the problems of soil salinity and waterlogging in India. The general guidelines that arise on the behalf of this review paper are to adapt drain depth >1.2 m and spacing depending on soil texture classification, i.e., 100-150 m for light-textured soils, 50-100 m for medium-textured soils and 30-50 m heavy-textured soils, for better result obtained from the problem areas in Indian soil and climatic conditions. An attempt has been made in the manner of literature survey to highlight the salient features of these studies, and it is hopeful to go a long way in selecting design parameters for subsurface drainage problems in the future with similar soil, water table and climatic conditions.

  18. Decomposition of soil organic matter from boreal black spruce forest: Environmental and chemical controls

    USGS Publications Warehouse

    Wickland, K.P.; Neff, J.C.

    2008-01-01

    Black spruce forests are a dominant covertype in the boreal forest region, and they inhabit landscapes that span a wide range of hydrologic and thermal conditions. These forests often have large stores of soil organic carbon. Recent increases in temperature at northern latitudes may be stimulating decomposition rates of this soil carbon. It is unclear, however, how changes in environmental conditions influence decomposition in these systems, and if substrate controls of decomposition vary with hydrologic and thermal regime. We addressed these issues by investigating the effects of temperature, moisture, and organic matter chemical characteristics on decomposition of fibric soil horizons from three black spruce forest sites. The sites varied in drainage and permafrost, and included a "Well Drained" site where permafrost was absent, and "Moderately well Drained" and "Poorly Drained" sites where permafrost was present at about 0.5 m depth. Samples collected from each site were incubated at five different moisture contents (2, 25, 50, 75, and 100% saturation) and two different temperatures (10??C and 20??C) in a full factorial design for two months. Organic matter chemistry was analyzed using pyrolysis gas chromatography-mass spectrometry prior to incubation, and after incubation on soils held at 20??C, 50% saturation. Mean cumulative mineralization, normalized to initial carbon content, ranged from 0.2% to 4.7%, and was dependent on temperature, moisture, and site. The effect of temperature on mineralization was significantly influenced by moisture content, as mineralization was greatest at 20??C and 50-75% saturation. While the relative effects of temperature and moisture were similar for all soils, mineralization rates were significantly greater for samples from the "Well Drained" site compared to the other sites. Variations in the relative abundances of polysaccharide-derivatives and compounds of undetermined source (such as toluene, phenol, 4-methyl phenol, and several unidentifiable compounds) could account for approximately 44% of the variation in mineralization across all sites under ideal temperature and moisture conditions. Based on our results, changes in temperature and moisture likely have similar, additive effects on in situ soil organic matter (SOM) decomposition across a wide range of black spruce forest systems, while variations in SOM chemistry can lead to significant differences in decomposition rates within and among forest sites. ?? 2007 Springer Science+Business Media B.V.

  19. Solar project description for Design Construction Association single family dwelling, Big Fork, Montana

    NASA Astrophysics Data System (ADS)

    1980-04-01

    A solar energy system was installed in a 2100 sq ft house located in Big Fork, Montana. The system is designed to provide solar energy for heating and domestic hot water. Solar energy is collected by flat plate collectors with a gross area of 792 square feet. The collector banks are mounted on the roof of the house and face due south at an angle of 45 deg to the horizontal optimizing solar energy collection. Solar energy is transferred from the collector array to a 1500 gallon storage tank. Water is used as the heat collection, transfer and storage medium. Freeze protection is provided by use of a drain down system. Space heating demands are met by circulating hot water from storage through baseboard units in the distribution system of the house. Auxiliary space heating is provided by an electrical heating element in the boiler. Similarly, an electrical heating element in the DHW tank provides energy for water heating. The dwelling was fully instrumented for performance evaluation since October 1977 and the data is integrated into the National Solar Data Network.

  20. Design and analysis of optimised class E power amplifier using shunt capacitance in the output structure

    NASA Astrophysics Data System (ADS)

    Hayati, Mohsen; Roshani, Sobhan; Zirak, Ali Reza

    2017-05-01

    In this paper, a class E power amplifier (PA) with operating frequency of 1 MHz is presented. MOSFET non-linear drain-to-source parasitic capacitance, linear external capacitance at drain-to-source port and linear shunt capacitance in the output structure are considered in design theory. One degree of freedom is added to the design of class E PA, by assuming the shunt capacitance in the output structure in the analysis. With this added design degree of freedom it is possible to achieve desired values for several parameters, such as output voltage, load resistance and operating frequency, while both zero voltage and zero derivative switching (ZVS and ZDS) conditions are satisfied. In the conventional class E PA, high value of peak switch voltage results in limitations for the design of amplifier, while in the presented structure desired specifications could be achieved with the safe margin of peak switch voltage. The results show that higher operating frequency and output voltage can also be achieved, compared to the conventional structure. PSpice software is used in order to simulate the designed circuit. The presented class E PA is designed, fabricated and measured. The measured results are in good agreement with simulation and theory results.

  1. TRAC-PF1 code verification with data from the OTIS test facility. [Once-Through Intergral System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Childerson, M.T.; Fujita, R.K.

    1985-01-01

    A computer code (TRAC-PF1/MOD1) developed for predicting transient thermal and hydraulic integral nuclear steam supply system (NSSS) response was benchmarked. Post-small break loss-of-coolant accident (LOCA) data from a scaled, experimental facility, designated the One-Through Integral System (OTIS), were obtained for the Babcock and Wilcox NSSS and compared to TRAC predictions. The OTIS tests provided a challenging small break LOCA data set for TRAC verification. The major phases of a small break LOCA observed in the OTIS tests included pressurizer draining and loop saturation, intermittent reactor coolant system circulation, boiler-condenser mode, and the initial stages of refill. The TRAC code wasmore » successful in predicting OTIS loop conditions (system pressures and temperatures) after modification of the steam generator model. In particular, the code predicted both pool and auxiliary-feedwater initiated boiler-condenser mode heat transfer.« less

  2. Structural alterations in tumor-draining lymph nodes before papillary thyroid carcinoma metastasis.

    PubMed

    Hinson, Andrew M; Massoll, Nicole A; Jolly, Lee Ann; Stack, Brendan C; Bodenner, Donald L; Franco, Aime T

    2017-08-01

    The purpose of this study was to define and characterize the thyroid tumor-draining lymph nodes in genetically engineered mice harboring thyroid-specific expression of oncogenic Braf V600E with and without Pten insufficiency. After intratumoral injection of methylene blue, the lymphatic drainage of the thyroid gland was visualized in real time. The thyroid gland/tumor was resected en bloc with the respiratory system for histological analysis. Although mice harboring Braf V600E mutations were smaller in body size compared with their wild-type (WT) littermates, the size of their thyroid glands and deep cervical lymph nodes were significantly larger. Additionally, the tumor-draining lymph nodes showed increased and enlarged lymphatic sinuses that were distributed throughout the cortex and medulla. Tumor-reactive lymphadenopathy and histiocytosis, but no frank metastases, were observed in all mice harboring Braf V600E mutations. The tumor-draining lymph nodes undergo significant structural alterations in immunocompetent mice, and this may represent a primer for papillary thyroid carcinoma (PTC) metastasis. © 2017 Wiley Periodicals, Inc.

  3. Shallow Groundwater Discharge into Urban Drains: Identifying the Missing Link to Define Urban Typologies for Impact Assessment of Urbanization on Water and Nutrient Balances

    NASA Astrophysics Data System (ADS)

    Ocampo, C. J.; Oldham, C. E.

    2015-12-01

    Groundwater and surface water (GW-SW) interaction in drains of many sandy coastal plain areas displays an ephemeral hydrological regime, as often shifts occur in their hydraulic functioning from a losing to a gaining water conditions upon the position of the surrounding shallow water table (SWT). Urbanization in such areas and stormwater management strategies enhancing infiltration have the potential to alter the infiltration rates and the subsurface water storage dynamics with consequences for the residence time of the water and nutrient transformations prior their discharge into receiving SW drains. Identifying first order control on the above processes will assist the improvement of assessment tools for better urban development. This work presents findings on the hydrodynamics of the GW-SW water exchange in two drains of the Perth Coastal Plain area (Western Australia, Australia) impacted by a SWT developing on a layered variable texture soil: a peri-urban drain and a restored living stream drain in urban residential area. A multi-technique approach was used to investigate water mass balance and fluxes over a reach scale and involved continuous records of hydrometric data for GW-SW interactions, passive tracers for water pathway identification, pore water temperature for vertical water exchange, and differential SW discharge using an Acoustic Doppler Current Profiler. Results highlighted differences in the GW-SW interactions between both drains under stormflow and baseflow conditions. A substantial increase of GW discharge into the drain coincided with the full development of a SWT over a seasonal scale at the peri-urban drain, which suggests a more natural water infiltration and redistribution in the subsurface. In contrast, a large volume of infiltrated rain water was discharged into the living stream over a period of few weeks regardless of the development of the surrounding SWT, which suggests the influence of underground pipe system in water redistribution. The results contributed to identify key physical parameters to define urban typologies, quantify the subsurface storage discharge and residence time, and finally assess the transport and transformations of nutrients using a generalised Damköhler number. Future work will populate the framework with other study cases.

  4. MODFLOW-2005 : the U.S. Geological Survey modular ground-water model--the ground-water flow process

    USGS Publications Warehouse

    Harbaugh, Arlen W.

    2005-01-01

    This report presents MODFLOW-2005, which is a new version of the finite-difference ground-water model commonly called MODFLOW. Ground-water flow is simulated using a block-centered finite-difference approach. Layers can be simulated as confined or unconfined. Flow associated with external stresses, such as wells, areal recharge, evapotranspiration, drains, and rivers, also can be simulated. The report includes detailed explanations of physical and mathematical concepts on which the model is based, an explanation of how those concepts are incorporated in the modular structure of the computer program, instructions for using the model, and details of the computer code. The modular structure consists of a MAIN Program and a series of highly independent subroutines. The subroutines are grouped into 'packages.' Each package deals with a specific feature of the hydrologic system that is to be simulated, such as flow from rivers or flow into drains, or with a specific method of solving the set of simultaneous equations resulting from the finite-difference method. Several solution methods are incorporated, including the Preconditioned Conjugate-Gradient method. The division of the program into packages permits the user to examine specific hydrologic features of the model independently. This also facilitates development of additional capabilities because new packages can be added to the program without modifying the existing packages. The input and output systems of the computer program also are designed to permit maximum flexibility. The program is designed to allow other capabilities, such as transport and optimization, to be incorporated, but this report is limited to describing the ground-water flow capability. The program is written in Fortran 90 and will run without modification on most computers that have a Fortran 90 compiler.

  5. Detention basin alternative outlet design study.

    DOT National Transportation Integrated Search

    2016-10-01

    This study examines the outlets structures CDOT has historically employed to drain water quality treatment detention basins and flood control basins, presents two new methods of metering the water quality capture volume (WQCV), namely 1) the Elliptic...

  6. Occurrence and Transport of Agricultural Chemicals in Leary Weber Ditch Basin, Hancock County, Indiana, 2003-04

    USGS Publications Warehouse

    Baker, Nancy T.; Stone, Wesley W.; Wilson, John T.; Meyer, Michael T.

    2006-01-01

    Leary Weber Ditch Basin, Hancock County, Indiana, is one of seven first-order basins selected from across the United States as part of the Agricultural Chemicals: Source, Transport, and Fate study conducted by the National Water-Quality Assessment Program of the U.S. Geological Survey. The nationwide study was designed to increase the understanding of the links between the sources of water and agricultural chemicals (nutrients and pesticides) and the transport and fate of these chemicals through the environment. Agricultural chemicals were detected in Leary Weber Ditch and in every associated hydrologic compartment sampled during 2003 and 2004. Pesticides were detected more frequently in samples collected from overland flow and from the ditch itself and less frequently in ground-water samples. The lowest concentrations of pesticides and nutrients were detected in samples of rain, soil water, and ground water. The highest concentrations of pesticides and nutrients were detected in samples of tile-drain water, overland flow, and water from Leary Weber Ditch. Samples collected from the tile drain, overland flow and Leary Weber Ditch soon after chemical applications to the fields and coincident with rainfall and increased streamflow had higher concentrations of pesticides and nutrients than samples collected a longer time after the chemicals were applied. A mass-balance mixing analysis based on potassium concentrations indicated that tile drains are the primary contributor of water to Leary Weber Ditch, but overland flow is also an important contributor during periods of high-intensity rainfall. When maximum rainfall intensity was 0.5 inches per hour or lower, overland flow contributed about 10 percent and tile drains contributed about 90 percent of the flow to Leary Weber Ditch. When maximum rainfall intensity was 0.75 inches per hour or greater, overland flow contributed about 40 percent and tile drains contributed about 60 percent of the flow to the ditch. Ground-water flow to Leary Weber Ditch was negligible. Tile drains are an important agricultural-chemical transport path to Leary Weber Ditch, based on the hydrologic contributions of overland flow and tile drains to the ditch. Overland flow is also an important agricultural-chemical transport pathway during high-intensity rainfall; however, storms with high-intensity rainfall are sporadic throughout the year. Tile drains and the soil water moving to the tile drains are the primary transport pathway for agricultural-chemical transport to Leary Weber Ditch during most storms as well as between storms.

  7. Use of laterally placed vacuum drains for management of aural hematomas in five dogs.

    PubMed

    Pavletic, Michael M

    2015-01-01

    5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.

  8. Environmental Setting of the Sugar Creek and Leary Weber Ditch Basins, Indiana, 2002-04

    USGS Publications Warehouse

    Lathrop, Timothy R.

    2006-01-01

    The U.S. Geological Survey operates streamflow-gaging stations at Sugar Creek at New Palestine and at Leary Weber Ditch at Mohawk within the study area. Mean daily streamflow for Sugar Creek is higher than streamflow at Leary Weber Ditch. Through most of its length, Sugar Creek is a gaining stream and base flow is supported by ground-water sources. At Leary Weber Ditch, there is little to no streamflow when tile drains are dry. Modifications to the natural hydrology of the study area include a large system of tile drains, the intersection of Sugar Creek by several major roads, and outflows from nearby wastewater-treatment plants. Leary Weber Ditch is affected only by tile drains.

  9. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors.

    PubMed

    Giusi, G; Giordano, O; Scandurra, G; Rapisarda, M; Calvi, S; Ciofi, C

    2016-04-01

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz(1/2), while DC performances are limited only by the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.

  10. Use of Subdural Evacuating Port System Following Open Craniotomy with Excision of Native Dura and Membranes for Management of Chronic Subdural Hematoma

    PubMed Central

    Bach, Ashley; McDermott, Michael W.

    2017-01-01

    An 86-year-old woman was admitted to the intensive care unit with a chronic subdural hematoma (CSDH) and rapid onset of worsening neurological symptoms. She was taken to the operating room for a mini-craniotomy for evacuation of the CSDH including excision of the dura and CSDH membrane. Postoperatively, a subdural evacuation port system (SEPS) was integrated into the craniotomy site and left in place rather than a traditional subdural catheter drain to evacuate the subdural space postoperatively. The patient had a good recovery and improvement of symptoms after evacuation and remained clinically well after the SEPS was removed. We offer the technique of dura and CSDH membrane excision plus SEPS drain as an effective postoperative alternative to the standard craniotomy leaving the native dura intact with traditional subdural drain that overlies the cortical surface of the brain in treating patients with CSDH. PMID:28560123

  11. High sensitivity measurement system for the direct-current, capacitance-voltage, and gate-drain low frequency noise characterization of field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giusi, G.; Giordano, O.; Scandurra, G.

    Measurements of current fluctuations originating in electron devices have been largely used to understand the electrical properties of materials and ultimate device performances. In this work, we propose a high-sensitivity measurement setup topology suitable for the automatic and programmable Direct-Current (DC), Capacitance-Voltage (CV), and gate-drain low frequency noise characterization of field effect transistors at wafer level. Automatic and programmable operation is particularly useful when the device characteristics relax or degrade with time due to optical, bias, or temperature stress. The noise sensitivity of the proposed topology is in the order of fA/Hz{sup 1/2}, while DC performances are limited only bymore » the source and measurement units used to bias the device under test. DC, CV, and NOISE measurements, down to 1 pA of DC gate and drain bias currents, in organic thin film transistors are reported to demonstrate system operation and performances.« less

  12. Lymphatics in Neurological Disorders: A neuro-lympho-vascular Component of Multiple Sclerosis and Alzheimer’s Disease

    PubMed Central

    Louveau, Antoine; Mesquita, Sandro Da; Kipnis, Jonathan

    2016-01-01

    Summary Lymphatic vasculature drains interstitial fluids, which contain the tissue’s waste products and ensures immune surveillance of the tissues, allowing immune-cell recirculation. Until recently the central nervous system (CNS) was considered to be devoid of a conventional lymphatic vasculature. The recent discovery in the meninges of a lymphatic network that drains the CNS calls into question classic models for the drainage of macromolecules and immune cells from the CNS. In the context of neurological disorders, the presence of a lymphatic system draining the CNS potentially offers a new player and a new avenue for therapy. In this review, we will attempt to integrate the known primary functions of the tissue lymphatic vasculature that exists in peripheral organs with the proposed function of meningeal lymphatic vessels in neurological disorders, specifically multiple sclerosis and Alzheimer’s disease. We propose that these (and potentially other) neurological afflictions can be viewed as diseases with neuro-lympho-vascular component and should be therapeutically targeted as such. PMID:27608759

  13. Initial Investigation on the Aerodynamic Performance of Flapping Wings for Nano Air Vehicles

    DTIC Science & Technology

    2008-02-01

    Experiments with Primitive Equations”, Monthly Weather Review, 93:99-164, 1963. 36. Yuan, W., Schilling, R., “Numerical Simulation of the Draft Tube and...LE and TE wake vorticity – Fully flexible wake – Linear approximation of Kutta condition yields a linear system of equations at each time step...all cases one must consider the drain rate. High drain rates substantially diminish capacity! Some batteries simply not capable of delivering

  14. Stabilizing Gas Bearings In Free-Piston Machines

    NASA Technical Reports Server (NTRS)

    Dhar, Manmohan

    1995-01-01

    Gas bearings and clearance seals between pistons and cylinders in free-piston machines designed to reduce undesired dynamic forces and torques on pistons, gas bearings, and cylinders. Circumferential grooves and drain galleries added to piston or cylinder in improved design. Provides stabilization without significant reduction in length of seal, or significant increase in leakage and consequent reduction of efficiency.

  15. A new design approach for enhancement of DC/RF characteristics with improved ambipolar conduction of charge plasma TFET: proposal, and optimization

    NASA Astrophysics Data System (ADS)

    Aslam, Mohd.; Sharma, Dheeraj; Yadav, Shivendra; Soni, Deepak; Bajaj, Varun

    2018-04-01

    This article presents a new device structure to suppress ambipolarity with enhanced electrostatic characteristics of charge plasma TFET (CP-TFET). Here, implantation of a metal angle (MA) of low workfunction inside the high-k dielectric (HfO2) layer near source/channel interface gives excellent improvement in DC and RF characteristics of the proposed device. Deposition of MA is advantageous to increase abruptness of source/channel junction for reducing the tunneling barrier. Along with MA placement, the metal electrode, which is placed over the silicon wafer for inducing N+ drain region, is divided into the two parts of low and high workfunctions. The workfunction of the part of metal electrode near the channel region is taken comparatively higher than the other part to restrict the tunneling of holes at drain/channel junction under negative bias (-V_gs) condition. Such concept induces asymmetrical concentration of charge carriers in the drain region, which widens the tunneling barrier at the drain/channel interface. Consequently, the proposed device shows better RF performance along with suppressed ambipolar conduction. Furthermore, reliability of conventional and proposed structures has been tested in terms of linearity. Simultaneously, the effect of workfunction and length variation of MA on the device characteristics is analyzed in optimization section of the article.

  16. Reactor Simulator Testing Overview

    NASA Technical Reports Server (NTRS)

    Schoenfeld, Michael P.

    2013-01-01

    OBJECTIVE: Integrated testing of the TDU components TESTING SUMMARY: a) Verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. b) Thermal test heat regeneration design aspect of a cold trap purification filter. c) Pump performance test at pump voltages up to 150 V (targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V). TESTING HIGHLIGHTS: a) Gas and vacuum ground support test equipment performed effectively for NaK fill, loop pressurization, and NaK drain operations. b) Instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

  17. An underlap field-effect transistor for electrical detection of influenza

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Won; Choi, Sung-Jin; Ahn, Jae-Hyuk; Moon, Dong-Il; Park, Tae Jung; Lee, Sang Yup; Choi, Yang-Kyu

    2010-01-01

    An underlap channel-embedded field-effect transistor (FET) is proposed for label-free biomolecule detection. Specifically, silica binding protein fused with avian influenza (AI) surface antigen and avian influenza antibody (anti-AI) were designed as a receptor molecule and a target material, respectively. The drain current was significantly decreased after the binding of negatively charged anti-AI on the underlap channel. A set of control experiments supports that only the biomolecules on the underlap channel effectively modulate the drain current. With the merits of a simple fabrication process, complementary metal-oxide-semiconductor compatibility, and enhanced sensitivity, the underlap FET could be a promising candidate for a chip-based biosensor.

  18. Improving off-state leakage characteristics for high voltage AlGaN/GaN-HFETs on Si substrates

    NASA Astrophysics Data System (ADS)

    Moon, Sung-Woon; Twynam, John; Lee, Jongsub; Seo, Deokwon; Jung, Sungdal; Choi, Hong Goo; Shim, Heejae; Yim, Jeong Soon; Roh, Sungwon D.

    2014-06-01

    We present a reliable process and design technique for realizing high voltage AlGaN/GaN hetero-junction field effect transistors (HFETs) on Si substrates with very low and stable off-state leakage current characteristics. In this work, we have investigated the effects of the surface passivation layer, prepared by low pressure chemical vapor deposition (LPCVD) of silicon nitride (SiNx), and gate bus isolation design on the off-state leakage characteristics of metal-oxide-semiconductor (MOS) gate structure-based GaN HFETs. The surface passivated devices with gate bus isolation fully surrounding the source and drain regions showed extremely low off-state leakage currents of less than 20 nA/mm at 600 V, with very small variation. These techniques were successfully applied to high-current devices with 80-mm gate width, yielding excellent off-state leakage characteristics within a drain voltage range 0-700 V.

  19. Automatic dispensing of liquid nitrogen in submilliliter doses

    NASA Astrophysics Data System (ADS)

    Milner, C. J.

    1984-10-01

    Well-controlled doses of 0.2 to 0.5 ml of liquid nitrogen are delivered, on electrical signal (not more than once per 5 s), as fills of a miniature bucket raised by an automatic hoist. The bucket is lifted, brimming, from the storage flask and then moved sideways until over the receiver. At this point, a steel ball, which has been resting in and sealing a drain hole in the bucket, is lifted from its seat by a magnet fixed alongside the (now descending) bucket. Design features are outlined: some alternative designs, valving liquid through a short drain tube fixed in the storage flask, are briefly reviewed. In tests the device delivered 74 g (approx. 260 doses) during 63 min, the loss by evaporation meanwhile being 11 g from the bucket, implying a transfer efficiency of 87%. An indirect measure indicated the dose sizes as 354±10 μl approximately.

  20. Performance and Design Considerations of a Novel Dual-Material Gate Carbon Nanotube Field-Effect Transistors: Nonequilibrium Green's Function Approach

    NASA Astrophysics Data System (ADS)

    Arefinia, Zahra; Orouji, Ali A.

    2009-02-01

    The concept of dual-material gate (DMG) is applied to the carbon nanotube field-effect transistor (CNTFET) with doped source and drain extensions, and the features exhibited by the resulting new structure, i.e., the DMG-CNTFET structure, have been examined for the first time by developing a two-dimensional (2D) full quantum simulation. The simulations have been done by the self-consistent solution of 2D Poisson-Schrödinger equations, within the nonequilibrium Green's function (NEGF) formalism. The results show DMG-CNTFET decreases significantly leakage current and drain conductance and increases on-off current ratio and voltage gain as compared to the single material gate counterparts CNTFET. It is seen that short channel effects in this structure are suppressed because of the perceivable step in the surface potential profile, which screens the drain potential. Moreover, these unique features can be controlled by engineering the workfunction and length of the gate metals. Therefore, this work provides an incentive for further experimental exploration.

  1. Climate mitigation scenarios of drained peat soils

    NASA Astrophysics Data System (ADS)

    Kasimir Klemedtsson, Åsa; Coria, Jessica; He, Hongxing; Liu, Xiangping; Nordén, Anna

    2014-05-01

    The national inventory reports (NIR) submitted to the UNFCCC show Sweden - which as many other countries has wetlands where parts have been drained for agriculture and forestry purposes, - to annually emit 12 million tonnes carbon dioxide equivalents, which is more GHG'es than industrial energy use release in Sweden. Similar conditions can be found in other northern countries, having cool and wet conditions, naturally promoting peat accumulation, and where land use management over the last centuries have promoted draining activities. These drained peatland, though covering only 2% of the land area, have emissions corresponding to 20% of the total reported NIR emissions. This substantial emission contribution, however, is hidden within the Land Use Land Use Change and Forestry sector (LULUCF) where the forest Carbon uptake is even larger, which causes the peat soil emissions become invisible. The only drained soil emission accounted in the Swedish Kyoto reporting is the N2O emission from agricultural drained organic soils of the size 0.5 million tonnes CO2e yr-1. This lack of visibility has made incentives for land use change and management neither implemented nor suggested, however with large potential. Rewetting has the potential to decrease soil mineralization, why CO2 and N2O emissions are mitigated. However if the soil becomes very wet CH4 emission will increase together with hampered plant growth. By ecological modeling, using the CoupModel the climate change mitigation potential have been estimated for four different land use scenarios; 1, Drained peat soil with Spruce (business as usual scenario), 2, raised ground water level to 20 cm depth and Willow plantation, 3, raised ground water level to 10 cm depth and Reed Canary Grass, and 4, rewetting to an average water level in the soil surface with recolonizing wetland plants and mosses. We calculate the volume of biomass production per year, peat decomposition, N2O emission together with nitrate and DOC/POC leakage. Based on the modelling results a cost benefit analysis is performed (economics), guiding to the design of environmental policies needed for land use change to come true.

  2. Soil surface CO2 flux in a boreal black spruce fire chronosequence

    NASA Astrophysics Data System (ADS)

    Wang, Chuankuan; Bond-Lamberty, Ben; Gower, Stith T.

    2003-02-01

    Understanding the effects of wildfire on the carbon (C) cycle of boreal forests is essential to quantifying the role of boreal forests in the global carbon cycle. Soil surface CO2 flux (Rs), the second largest C flux in boreal forests, is directly and indirectly affected by fire and is hypothesized to change during forest succession following fire. The overall objective of this study was to measure and model Rs for a black spruce (Picea mariana [Mill.] BSP) postfire chronosequence in northern Manitoba, Canada. The experiment design was a nested factorial that included two soil drainage classes (well and poorly drained) × seven postfire aged stands. Specific objectives were (1) to quantify the relationship between Rs and soil temperature for different aged boreal black spruce forests in well-drained and poorly drained soil conditions, (2) to examine Rs dynamics along postfire successional stands, and (3) to estimate annual soil surface CO2 flux for these ecosystems. Soil surface CO2 flux was significantly affected by soil drainage class (p = 0.014) and stand age (p = 0.006). Soil surface CO2 flux was positively correlated to soil temperature (R2 = 0.78, p < 0.001), but different models were required for each drainage class × aged stand combination. Soil surface CO2 flux was significantly greater at the well-drained than the poorly drained stands (p = 0.007) during growing season. Annual soil surface CO2 flux for the 1998, 1995, 1989, 1981, 1964, 1930, and 1870 burned stands averaged 226, 412, 357, 413, 350, 274, and 244 g C m-2 yr-1 in the well-drained stands and 146, 380, 300, 303, 256, 233, and 264 g C m-2 yr-1 in the poorly drained stands. Soil surface CO2 flux during the winter (from 1 November to 30 April) comprised from 5 to 19% of the total annual Rs. We speculate that the smaller soil surface CO2 flux in the recently burned than the older stands is mainly caused by decreased root respiration.

  3. Soil surface CO2 flux in a boreal black spruce fire chronosequence

    NASA Astrophysics Data System (ADS)

    Wang, Chuankuan; Bond-Lamberty, Ben; Gower, Stith T.

    2002-02-01

    Understanding the effects of wildfire on the carbon (C) cycle of boreal forests is essential to quantifying the role of boreal forests in the global carbon cycle. Soil surface CO2 flux (Rs), the second largest C flux in boreal forests, is directly and indirectly affected by fire and is hypothesized to change during forest succession following fire. The overall objective of this study was to measure and model Rs for a black spruce (Picea mariana [Mill.] BSP) postfire chronosequence in northern Manitoba, Canada. The experiment design was a nested factorial that included two soil drainage classes (well and poorly drained) × seven postfire aged stands. Specific objectives were (1) to quantify the relationship between Rs and soil temperature for different aged boreal black spruce forests in well-drained and poorly drained soil conditions, (2) to examine Rs dynamics along postfire successional stands, and (3) to estimate annual soil surface CO2 flux for these ecosystems. Soil surface CO2 flux was significantly affected by soil drainage class (p = 0.014) and stand age (p = 0.006). Soil surface CO2 flux was positively correlated to soil temperature (R2 = 0.78, p < 0.001), but different models were required for each drainage class × aged stand combination. Soil surface CO2 flux was significantly greater at the well-drained than the poorly drained stands (p = 0.007) during growing season. Annual soil surface CO2 flux for the 1998, 1995, 1989, 1981, 1964, 1930, and 1870 burned stands averaged 226, 412, 357, 413, 350, 274, and 244 g C m-2 yr-1 in the well-drained stands and 146, 380, 300, 303, 256, 233, and 264 g C m-2 yr-1 in the poorly drained stands. Soil surface CO2 flux during the winter (from 1 November to 30 April) comprised from 5 to 19% of the total annual Rs. We speculate that the smaller soil surface CO2 flux in the recently burned than the older stands is mainly caused by decreased root respiration.

  4. A prospective randomized study of use of drain versus no drain after burr-hole evacuation of chronic subdural hematoma.

    PubMed

    Singh, Amit Kumar; Suryanarayanan, Bhaskar; Choudhary, Ajay; Prasad, Akhila; Singh, Sachin; Gupta, Laxmi Narayan

    2014-01-01

    Chronic subdural hematoma (CSDH) recurs after surgical evacuation in 5-30% of patients. Inserting subdural drain might reduce the recurrence rate, but is not commonly practiced. There are few prospective studies to evaluate the effect of subdural drains. A prospective randomized study to investigate the effect of subdural drains in the on recurrence rates and clinical outcome following burr-hole drainage (BHD) of CSDH was undertaken. During the study period, 246 patients with CSDH were assessed for eligibility. Among 200 patients fulfilling the eligibility criteria, 100 each were assigned to "drain group" (drain inserted into the subdural space following BHD) and "without drain group" (subdural drain was not inserted following BHD) using random allocation software. The primary end point was recurrence needing re-drainage up to a period of 6 months from surgery. Recurrence occurred in 9 of 100 patients with a drain, and 26 of 100 patients in without drain group (P = 0.002). The mortality was 5% in patients with drain and 4% in patients without drain group (P = 0.744). The medical and surgical complications were comparable between the two study groups. Use of a subdural drain after burr-hole evacuation of a CSDH reduces the recurrence rate and is not associated with increased complications.

  5. Simulating the Effects of Drainage and Agriculture on Hydrology and Sediment in the Minnesota River Basin

    NASA Astrophysics Data System (ADS)

    Downer, C. W.; Pradhan, N. R.; Skahill, B. E.; Banitt, A. M.; Eggers, G.; Pickett, R. E.

    2014-12-01

    Throughout the Midwest region of the United States, slopes are relatively flat, soils tend to have low permeability, and local water tables are high. In order to make the region suitable for agriculture, farmers have installed extensive networks of ditches to drain off excess surface water and subsurface tiles to lower the water table and remove excess soil water in the root zone that can stress common row crops, such as corn and soybeans. The combination of tiles, ditches, and intensive agricultural land practices radically alters the landscape and hydrology. Within the watershed, tiles have outlets to both the ditch/stream network as well as overland locations, where the tile discharge appears to initiate gullies and exacerbate overland erosion. As part of the Minnesota River Basin Integrated Study we are explicitly simulating the tile and drainage systems in the watershed at multiple scales using the physics-based watershed model GSSHA (Gridded Surface Subsurface Hydrologic Analysis). The tile drainage system is simulated as a network of pipes that collect water from the local water table. Within the watershed, testing of the methods on smaller basins shows the ability of the model to simulate tile flow, however, application at the larger scale is hampered by the computational burden of simulating the flow in the complex tile drain networks that drain the agricultural fields. Modeling indicates the subsurface drains account for approximately 40% of the stream flow in the Seven Mile Creek sub-basin account in the late spring and early summer when the tile is flowing. Preliminary results indicate that agricultural tile drains increase overland erosion in the Seven Mile Creek watershed.

  6. Effect of inlet modelling on surface drainage in coupled urban flood simulation

    NASA Astrophysics Data System (ADS)

    Jang, Jiun-Huei; Chang, Tien-Hao; Chen, Wei-Bo

    2018-07-01

    For a highly developed urban area with complete drainage systems, flood simulation is necessary for describing the flow dynamics from rainfall, to surface runoff, and to sewer flow. In this study, a coupled flood model based on diffusion wave equations was proposed to simulate one-dimensional sewer flow and two-dimensional overland flow simultaneously. The overland flow model provides details on the rainfall-runoff process to estimate the excess runoff that enters the sewer system through street inlets for sewer flow routing. Three types of inlet modelling are considered in this study, including the manhole-based approach that ignores the street inlets by draining surface water directly into manholes, the inlet-manhole approach that drains surface water into manholes that are each connected to multiple inlets, and the inlet-node approach that drains surface water into sewer nodes that are connected to individual inlets. The simulation results were compared with a high-intensity rainstorm event that occurred in 2015 in Taipei City. In the verification of the maximum flood extent, the two approaches that considered street inlets performed considerably better than that without street inlets. When considering the aforementioned models in terms of temporal flood variation, using manholes as receivers leads to an overall inefficient draining of the surface water either by the manhole-based approach or by the inlet-manhole approach. Using the inlet-node approach is more reasonable than using the inlet-manhole approach because the inlet-node approach greatly reduces the fluctuation of the sewer water level. The inlet-node approach is more efficient in draining surface water by reducing flood volume by 13% compared with the inlet-manhole approach and by 41% compared with the manhole-based approach. The results show that inlet modeling has a strong influence on drainage efficiency in coupled flood simulation.

  7. Applications of thermal energy storage to waste heat recovery in the food processing industry

    NASA Astrophysics Data System (ADS)

    Trebilcox, G. J.; Lundberg, W. L.

    1981-03-01

    The canning segment of the food processing industry is a major energy user within that industry. Most of its energy demand is met by hot water and steam and those fluids, in addition to product cooling water, eventually flow from the processes as warm waste water. To minimize the possibility of product contamination, a large percentage of that waste water is sent directly to factory drains and sewer systems without being recycled and in many cases the thermal energy contained by the waste streams also goes unreclaimed and is lost from further use. Waste heat recovery in canning facilities can be performed economically using systems that employ thermal energy storage (TES). A project was proposed in which a demonstration waste heat recovery system, including a TES feature, would be designed, installed and operated.

  8. Subsurface irrigation of potato crop (Solanum tuberosum ssp. Andigena) in Suka Kollus with different drainage systems

    NASA Astrophysics Data System (ADS)

    Serrano-Coronel, Genaro; Chipana-Rivera, René; Fátima Moreno-Pérez, María; Roldán-Cañas, José

    2016-04-01

    Among the most important hydraulic structures of pre-Hispanic ancestral technology developed in the Andean region, we find the suka kollus, aymara word, called also waru waru, en quechua or raised fields, in English. They are raised platforms surrounded by water canals that irrigate subsurface, but also have the function of draining, to deal with floods because they are surrounding Lake Titicaca. They also have the property of generating a thermoregulatory effect to crops, depending on the configuration of the channels and platforms. Such agro-ecosystems are being abandoned, however, if properly addressed crop management and some drainage canals are replaced by underground drains for increased crop area could be very useful in enabling marginal soils affected by salts and / or excess water. For these reasons, the objective of this study was to evaluate the subsurface irrigation in the potato crop in suka kollus under a system of surface drainage, and mixed drainage (surface and subsurface). The study was conducted in marginal soils of Kallutaca area, located 30 km from the city of La Paz, Bolivia, at a height of 3892 m.a.s.l. The cultivation of the potato (Solanum tuberosum ssp. Andigena) was used. Four treatments were tested with different widths of the platforms: T1 (Control) with drainage through channels; T2 (replacing a channel by a drain); T3 (replacing two channels by two drains); T4 (replacing three channels by three drains). The flow of water into the soil from the water table was predominantly upward, except during periods of high rainfall. In terms of treatments, the flow in T1 was higher, mainly at weeks 8 to 11 after seedling emergence, coinciding with the phenological phases of flowering and at the beginning of the tuber ripening. It was followed by T3, T2 and T4 treatments, respectively. Tuber yield, if one considers that the channels detract arable land, was higher in the T3 treatment,16.4 Mg / ha, followed by T2 treatment, 15.2 Mg / ha, T1 treatment (Control) 7.3 Mg / ha and T4 treatment with 7.1 Mg / ha. Therefore, in the mixed system with two drains the best results were obtained.

  9. Reusable LH2 tank technology demonstration through ground test

    NASA Technical Reports Server (NTRS)

    Bianca, C.; Greenberg, H. S.; Johnson, S. E.

    1995-01-01

    The paper presents the project plan to demonstrate, by March 1997, the reusability of an integrated composite LH2 tank structure, cryogenic insulation, and thermal protection system (TPS). The plan includes establishment of design requirements and a comprehensive trade study to select the most suitable Reusable Hydrogen Composite Tank system (RHCTS) within the most suitable of 4 candidate structural configurations. The 4 vehicles are winged body with the capability to deliver 25,000 lbs of payload to a circular 220 nm, 51.6 degree inclined orbit (also 40,000 lbs to a 28.5 inclined 150 nm orbit). A prototype design of the selected RHCTS is established to identify the construction, fabrication, and stress simulation and test requirements necessary in an 8 foot diameter tank structure/insulation/TPS test article. A comprehensive development test program supports the 8 foot test article development and involves the composite tank itself, cryogenic insulation, and integrated tank/insulation/TPS designs. The 8 foot diameter tank will contain the integrated cryogenic insulation and TPS designs resulting from this development and that of the concurrent lightweight durable TPS program. Tank ground testing will include 330 cycles of LH2 filling, pressurization, body loading, depressurization, draining, and entry heating.

  10. Think Tanks

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A new inspection robot from Solex Robotics Systems was designed to eliminate hazardous inspections of petroleum and chemical storage tanks. The submersible robot, named Maverick, is used to inspect the bottoms of tanks, keeping the tanks operational during inspection. Maverick is able to provide services that will make manual tank inspections obsolete. While the inspection is conducted, Maverick's remote human operators remain safe outside of the tank. The risk to human health and life is now virtually eliminated. The risk to the environment is also minimal because there is a reduced chance of spillage from emptying and cleaning the tanks, where previously, tons of pollutants were released through the process of draining and refilling.

  11. Duplex System with Ectopic Ureter Opens into the Posterior Urethra: Case Report.

    PubMed

    Milicevic, Snjezana; Bijelic, Radojka; Krivokuca, Vladimir; Jakovljevic, Branislava

    2018-04-01

    Duplicated ureter or Duplex Collecting System is a congenital condition in which the ureteric bud, the embryological origin of the ureter, arises twice, resulting in two ureters draining a single kidney. This congenital anomaly is rare, and even rarer when the duplex system with ectopic ureter is present. This type of congenital anomaly is even more rarely diagnosed and surgically treated in adulthood. This case report presents a case of a 32-year-old male, who had a duplex collecting system with two ureters on the left side. Ectopic ureter, draining the upper pole of the left kidney, opened into the posterior urethra. In our patient, taking into account the clinical perspective, the renal tissue damaging of the upper pole which was not functional, partial nephrectomy and ureterectomy was successfully performed.

  12. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    PubMed

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  13. Modeling of coastal water contamination in Fortaleza (Northeastern Brazil).

    PubMed

    Pereira, S P; Rosman, P C C; Alvarez, C; Schetini, C A F; Souza, R O; Vieira, R H S F

    2015-01-01

    An important tool in environmental management projects and studies due to the complexity of environmental systems, environmental modeling makes it possible to integrate many variables and processes, thereby providing a dynamic view of systems. In this study the bacteriological quality of the coastal waters of Fortaleza (a state capital in Northeastern Brazil) was modeled considering multiple contamination sources. Using the software SisBaHiA, the dispersion of thermotolerant coliforms and Escherichia coli from three sources of contamination (local rivers, storm drains and submarine outfall) was analyzed. The models took into account variations in bacterial decay due to solar radiation and other environmental factors. Fecal pollution discharged from rivers and storm drains is transported westward by coastal currents, contaminating strips of beach water to the left of each storm drain or river. Exception to this condition only occurs on beaches protected by the breakwater of the harbor, where counterclockwise vortexes reverse this behavior. The results of the models were consistent with field measurements taken during the dry and the rainy season. Our results show that the submarine outfall plume was over 2 km from the nearest beach. The storm drains and the Maceió stream are the main factors responsible for the poor water quality on the waterfront of Fortaleza. The depollution of these sources would generate considerable social, health and economic gains for the region.

  14. Use of the Heimlich valve in a compact autotransfusion device.

    PubMed

    Schweitzer, E J; Hauer, J M; Swan, K G; Bresch, J R; Harmon, J W; Graeber, G M

    1987-05-01

    A compact device which evacuates blood from a hemothorax and facilitates rapid autotransfusion was evaluated in dogs. Experimental hemothorax was established surgically by incising the internal mammary artery through a thoracotomy with the animals under general anesthesia. Postoperatively the blood was drained by one of two methods. In the Heimlich valve group (n = 5), blood was drained by a chest tube through a one-way flutter valve into a collapsible plastic bag. In the Sorenson group (n = 5), blood was drained by a chest tube into the Sorenson Autotransfusion System. Blood from these two groups was then autotransfused. In the control group (n = 5), the drained blood was not autotransfused. Results showed no statistical difference between the two autotransfusion groups in the volume of blood collected, circulating fibrinogen levels, platelet counts, stroma-free hemoglobin levels, prothrombin time, or 51Cr-labeled RBC survival. There was a significant drop in the circulating platelet count, which returned to normal by 24 hours, in both groups of dogs which were autotransfused. We conclude that autotransfusion of blood collected by a compact device which utilizes a Heimlich valve and requires no suction is similar to using the Sorenson Autotransfusion System. It may be safe to use the Heimlich valve to collect blood for autotransfusion in clinical situations, where its qualities of simplicity, portability and a minimum requirement for storage space are desirable.

  15. An In Vivo Study of Low-Dose Intra-Articular Tranexamic Acid Application with Prolonged Clamping Drain Method in Total Knee Replacement: Clinical Efficacy and Safety

    PubMed Central

    Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj

    2015-01-01

    Background. Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05).  Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time. PMID:26583092

  16. Wastewater collection and treatment technologies for semi-urban areas of India: a case study.

    PubMed

    Sundaravadivel, M; Vigneswaran, S

    2001-01-01

    Sanitation and wastewater management problems in small and medium towns in India (referred to as "semi-urban areas"--SUAs) are distinctly different from those of large cities or rural villages. There is an apparent lack of choices of appropriate sanitation options for these semi-urban areas, leading them to adopt on-site sanitation technologies. A field study of four such small towns in India was conducted to evaluate the suitability of available low-cost wastewater collection and treatment technologies, in light of their current practice. Based on the field study, this paper suggests a system comprising "combined surface sewers" and "reed-bed channel" for collection and treatment of wastewater for semi-urban areas, that can utilize all the existing infrastructure to effect better sanitation at lower costs. The suggested system involves converting the existing open wastewater collection drains on the road sides, as "decentralized" networks of covered drains with simple structural modifications to collect both wastewater and stormwater; and, converting the large open drains on the outskirts of SUAs that carry wastewater to agricultural fields, as gravel media filled beds planted with local reeds. Cost estimates for the towns studied indicate this system to be over 70% cheaper compared to conventional collection and treatment systems.

  17. Aerosol can puncture device operational test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1994-05-03

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system`s fire/explosion proof characteristics, a study was undertaken to compare the baseline system`s design to commercially available puncturing devices. While the study found no areas which might indicate a riskmore » of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv.« less

  18. Efficiency of source control systems for reducing runoff pollutant loads: feedback on experimental catchments within Paris conurbation.

    PubMed

    Bressy, Adèle; Gromaire, Marie-Christine; Lorgeoux, Catherine; Saad, Mohamed; Leroy, Florent; Chebbo, Ghassan

    2014-06-15

    Three catchments, equipped with sustainable urban drainage systems (SUDS: vegetated roof, underground pipeline or tank, swale, grassed detention pond) for peak flow mitigation, have been compared to a reference catchment drained by a conventional separate sewer system in terms of hydraulic behaviour and discharged contaminant fluxes (organic matter, organic micropollutants, metals). A runoff and contaminant emission model has been developed in order to overcome land use differences. It has been demonstrated that the presence of peak flow control systems induces flow attenuation even for frequent rain events and reduces water discharges at a rate of about 50% depending on the site characteristics. This research has also demonstrated that this type of SUDS contributes to a significant reduction of runoff pollutant discharges, by 20%-80%. This level of reduction varies depending on the considered contaminant and on the design of the drainage system but is mostly correlated with the decrease in runoff volume. It could be improved if the design of these SUDS focused not only on the control of exceptional events but also targeted more explicitly the interception of frequent rain events. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Design optimization of the sensor spatial arrangement in a direct magnetic field-based localization system for medical applications.

    PubMed

    Marechal, Luc; Shaohui Foong; Zhenglong Sun; Wood, Kristin L

    2015-08-01

    Motivated by the need for developing a neuronavigation system to improve efficacy of intracranial surgical procedures, a localization system using passive magnetic fields for real-time monitoring of the insertion process of an external ventricular drain (EVD) catheter is conceived and developed. This system operates on the principle of measuring the static magnetic field of a magnetic marker using an array of magnetic sensors. An artificial neural network (ANN) is directly used for solving the inverse problem of magnetic dipole localization for improved efficiency and precision. As the accuracy of localization system is highly dependent on the sensor spatial location, an optimization framework, based on understanding and classification of experimental sensor characteristics as well as prior knowledge of the general trajectory of the localization pathway, for design of such sensing assemblies is described and investigated in this paper. Both optimized and non-optimized sensor configurations were experimentally evaluated and results show superior performance from the optimized configuration. While the approach presented here utilizes ventriculostomy as an illustrative platform, it can be extended to other medical applications that require localization inside the body.

  20. Research notes : free draining base materials properties.

    DOT National Transportation Integrated Search

    1992-04-01

    In the past few years, the Oregon Department of Transportation (ODOT) has started designing and constructing permeable bases in both flexible and rigid pavements. Two types of permeable bases have been used: one is asphalt treated permeable base and ...

  1. New Whole-House Case Study: William Ryan Homes, Tampa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    The builder worked with Consortium for Advanced Residential Buildings to design HERS-65 homes with energy-efficient heat pumps and programmable thermostats with humidity controls, foam-filled concrete block walls, draining house wrap, and airsealed kneewalls.

  2. A percutaneous drainage protocol for severe and moderately severe acute pancreatitis.

    PubMed

    Sugimoto, Motokazu; Sonntag, David P; Flint, Greggory S; Boyce, Cody J; Kirkham, John C; Harris, Tyler J; Carr, Sean M; Nelson, Brent D; Barton, Joshua G; Traverso, L William

    2015-11-01

    According to the revised Atlanta classification, severe and moderately severe acute pancreatitis (AP) includes patients with pancreatic and peripancreatic collections with or without organ failure. These collections suggest the presence of pancreatic juice leakage. The aim of this study was to evaluate the efficacy of a percutaneous catheter drainage (PCD) protocol designed to control leakage and decrease disease severity. Among 663 patients with clinical AP, 122 were classified as moderately severe or severe AP (all had collections). The computed tomography severity index (CTSI) score was calculated. The indication for PCD was based on progressive clinical signs and symptoms. Drain patency, position, and need for additional drainage sites were assessed using CT scans and drain studies initially every 3 days using a proactive protocol. Drain fluid was examined for amylase concentration and microbiological culture. Clinicopathological variables for patients with and without PCD were compared. Since there was no mortality, we used prolonged drainage time to measure the success of PCD. Within the group treated with PCD, variables that resulted in prolonged drainage time were analyzed. PCD was used in 47/122 (39 %) patients of which 33/47 (70 %) had necrosis. PCD cases had a median CTSI of 8 and were classified as moderately severe AP (57 %) and severe AP (43 %). Inhospital mortality was zero. Surgical necrosectomy was not required for patients with necrosis. Independent risk factors for prolonged drainage time were persistent organ failure >48 h (P = 0.001), CTSI 8-10 (P = 0.038), prolonged duration of amylase-rich fluid in drains (P < 0.001), and polymicrobial culture fluid in drains (P = 0.015). A proactive PCD protocol persistently maintaining drain patency advanced to the site of leak controlled the prolonged amylase in drainage fluid resulting in a mortality rate of zero.

  3. Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

    NASA Technical Reports Server (NTRS)

    Sunada, Eric; Birur, Gajanana C.; Ganapathi, Gani B.; Miller, Jennifer; Berisford, Daniel; Stephan, Ryan

    2010-01-01

    NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

  4. Conjunctivodacryocystorhinostomy using a high-density porous polyethylene-coated tear drain tube.

    PubMed

    Pushker, Neelam; Khurana, Saurbhi; Shrey, Dinesh; Bajaj, Mandeep S; Chawla, Bhavna; Chandra, Mahesh

    2013-08-01

    To evaluate the outcome of conjunctivodacryocystorhinostomy using a high-density porous polyethylene (HDPP)-coated tear drain tube. Patients with epiphora due to a proximal lacrimal system block were included in a prospective interventional case study. A total of 22 eyes were treated with lacrimal bypass surgery using the HDPP-coated tube. On follow-up (12-41 months), 21 eyes had a patent well-positioned tube with subjective relief of epiphora. In one eye, a loose sleeve was noted during surgery. The tube dislodged postoperatively and was removed. A high success rate with only a few minor complications is achievable using a HDPP-coated tear drain tube for lacrimal bypass surgery. Long-term follow-up is required to look for tube blockage due to conjunctival or nasal mucosal overgrowth.

  5. Corrective Action Investigation Plan for Corrective Action Unit 562: Waste Systems Nevada Test Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alfred Wickline

    2009-04-01

    Corrective Action Unit 562 is located in Areas 2, 23, and 25 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 562 is comprised of the 13 corrective action sites (CASs) listed below: • 02-26-11, Lead Shot • 02-44-02, Paint Spills and French Drain • 02-59-01, Septic System • 02-60-01, Concrete Drain • 02-60-02, French Drain • 02-60-03, Steam Cleaning Drain • 02-60-04, French Drain • 02-60-05, French Drain • 02-60-06, French Drain • 02-60-07, French Drain • 23-60-01, Mud Trap Drain and Outfall • 23-99-06, Grease Trap • 25-60-04, Buildingmore » 3123 Outfalls These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on December 11, 2008, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 562. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the corrective action investigation for CAU 562 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Perform field screening. • Collect and submit environmental samples for laboratory analysis to determine the nature and extent of any contamination released by each CAS. • Collect samples of source material to determine the potential for a release. • Collect samples of potential remediation wastes. • Collect quality control samples. This Corrective Action Investigation Plan has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; DOE, Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996; as amended February 2008). Under the Federal Facility Agreement and Consent Order, this Corrective Action Investigation Plan will be submitted to the Nevada Division of Environmental Protection for approval. Fieldwork will be conducted following approval of the plan.« less

  6. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    PubMed Central

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  7. A Brief History of Two Common Surgical Drains.

    PubMed

    Meyerson, Joseph M

    2016-01-01

    The use of surgical drains is commonplace in all types of surgical procedures, and rarely do we take the time to contemplate or investigate the origins of these critical devices. Every surgeon should be familiar with the Jackson-Pratt drain and Blake drain, 2 of the most frequently used closed suction, negative-pressure drainage devices in surgery. These drains are used throughout the body in a wide variety of surgical procedures. The development and differences between these 2 devices are seldom known by the practicing surgeon. In this article, we delve into the ancient history of drains, the creation and alterations of the closed suction, negative-pressure drain that paved the way for the Jackson-Pratt and Blake drain. Finally, we will discuss the variety of reservoirs that attach to these drains and the origin of the well-known adage of when to pull a drain.

  8. Force Dental Facility Design Guidance (AFDFDG).

    DTIC Science & Technology

    1998-06-01

    8217 Note: "A" designates 24"x48" drop in fluorescent light fixture having tubes with color rendering index greater than 90 (CRI...90). Since there are a varity of tube types to select from and varying lighting design concepts, certain tubes may be...terminated in utility center with 5/8" outside diameter (O.D.) tube . GRAVITY DRAIN, 1-1/2" nominal pipe protruding 1" from bottom of box. NOTE: Place

  9. Hydronic rooftop cooling systems

    DOEpatents

    Bourne, Richard C [Davis, CA; Lee, Brian Eric [Monterey, CA; Berman, Mark J [Davis, CA

    2008-01-29

    A roof top cooling unit has an evaporative cooling section that includes at least one evaporative module that pre-cools ventilation air and water; a condenser; a water reservoir and pump that captures and re-circulates water within the evaporative modules; a fan that exhausts air from the building and the evaporative modules and systems that refill and drain the water reservoir. The cooling unit also has a refrigerant section that includes a compressor, an expansion device, evaporator and condenser heat exchangers, and connecting refrigerant piping. Supply air components include a blower, an air filter, a cooling and/or heating coil to condition air for supply to the building, and optional dampers that, in designs that supply less than 100% outdoor air to the building, control the mixture of return and ventilation air.

  10. The Equipment of Using AZOLLA for O2-Supplimentation and its Test

    NASA Astrophysics Data System (ADS)

    Chen, Min; Liu, Xia-Shi; Bian, Zu-Liang; Liu, Chung-Chu

    The equipment of using Azolla for O2-supplementation and food-production in future space station was developed and tested. Dog was used as the O2-consumming animal. The design of this device considered both the requirement of Azolla growth, such as illumination, temperature, humidity, nutrition and biomass harvesting, and also the food supplement, excretion draining and temperature controlling for the dog under the condition of an airtight chamber for a relatively long duration. This device was preliminarily tested for O2-release by Azolla, and data about O2-supplementation by Azolla were obtained. Results showed that Azolla is one potential plant as O2-supplementation in future space station. Key words: Azolla, oxygen supply systems, test, chambers, closed ecological systems, oxygen supplement

  11. A study of the complications of small bore 'Seldinger' intercostal chest drains.

    PubMed

    Davies, Helen E; Merchant, Shairoz; McGown, Anne

    2008-06-01

    Use of small bore chest drains (<14F), inserted via the Seldinger technique, has increased globally over the last few years. They are now used as first line interventions in most acute medical situations when thoracostomy is required. Limited data are available on the associated complications. In this study, the frequency of complications associated with 12F chest drains, inserted using the Seldinger technique, was quantified. A retrospective case note audit was performed of consecutive patients requiring pleural drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.

  12. Development of a Contingency Capillary Wastewater Management Device

    NASA Technical Reports Server (NTRS)

    Thomas, Evan A.

    2010-01-01

    The Personal Body .Attached Liquid Liquidator (PBALL) is conceived as a passive, capillary driven contingency wastewater disposal device. In this contingency scenario, the airflow system on the NASA Crew Exploration Vehicle (CEV) is assumed to have failed, leaving only passive hardware and vacuum vent to dispose of the wastewater. To meet these needs, the PBALL was conceived to rely on capillary action and urine wetting design considerations. The PBALL is designed to accommodate a range of wetting conditions, from 0deg < (theta)adv approx. 90deg, be adaptable for both male and female use, collect and retain up to a liter of urine, minimize splash-back, and allow continuous drain of the wastewater to vacuum while minimizing cabin air loss. A sub-scale PBALL test article was demonstrated on NASA's reduced gravity aircraft in April, 2010.

  13. Is the blocking of drainage channels in upland peats an effective means of reducing DOC loss at the catchment scale?

    NASA Astrophysics Data System (ADS)

    Turner, Kate; Worrall, Fred

    2010-05-01

    Only 3% of the earths land surface is covered by peatland yet boreal and subarctic peatlands store approximately 15-30% of the World's soil carbon as peat (Limpens et al. 2008). In comparison British bogs store carbon equivalent to 20 years worth of national emissions. The loss of carbon from these areas in the form of dissolved organic carbon (DOC) is increasing and it is expected to have grown by up to 40% by 2018. Extensive drainage of UK peatlands has been associated with dehydration of the peat, an increase in water colour and a loss of carbon storage. It has been considered that the blocking of these drainage channels represents a means of peat restoration and a way of reducing DOC loss. This study aims to assess the effectiveness of this drain blocking at both an individual drain scale and at a larger catchment scale. Gibson et al. (2009) considered the effects of blocking at a solely individual drain scale finding that a 20% drop in DOC export was recorded post blocking however this decrease was due to a reduction in water yield rather than a reduction in DOC concentration with the concentration record showing no significant reduction. The effect of external parameters become more pronounced as the DOC record is examined at larger scales. The catchment is an open system and water chemistry will be influence by mixing with water from other sources. Also it is likely that at some point the drains will cut across slope leading to the flow of any highly coloured water down slope, bypassing the blockages, and entering the surface waters downstream. Degradation of DOC will occur naturally downstream due to the effects of light and microbial activity. There is, consequently, a need to examine the wider effects of drain blocking at a catchment scale to ensure that what is observed for one drain transfers to the whole catchment. A series of blocked and unblocked catchments were studied in Upper Teesdale, Northern England. Drain water samples were taken at least daily at nine localities. These sites were located such that individual drains could be monitored in the context of a larger catchment. Water table depth, flow and weather parameters were recorded along with the collection of runoff and soil water samples. A detailed sampling programme was undertaken in which a series of drains were studied in the 12 months prior to and post blocking. This approach has allowed the effects of blocking on the carbon budget, water balance and flow pathways to be considered. Results indicate that the blocking of zero order drainage channels leads to a decrease in DOC export on an individual drain scale. However, this is due to a reduction in water yield rather than concentration. Concentrations are seen to rise by a small yet statistically significant amount in blocked zero order streams. The effect at a larger scale is more complex. Annual export values in the unblocked control catchment show a rise from zero to first order streams indicating that water is being added to the system at this scale from external spatially variable sources. This pattern is also recognised in the blocked catchment. The DOC concentration record in blocked drains at this larger scale however indicated a reduction relative to the unblocked catchment. This reduction points to a change in flow pathways post blocking as highly coloured water re-navigates its way downstream. References: Gibson H, Worrall F, Burt TP, Adamson JK (2009) DOC budgets of drained peat catchments: implications for DOC production in peat soils, Hydrological Processes 23(13) 1901-1911 Limpens J (2008) Peatlands and the carbon cycle: from local processes to global implications- a synthesis, Biogeosciences 5 1475-1491

  14. Engineering solutions to improve the removal of fecal indicator bacteria by bioinfiltration systems during intermittent flow of stormwater.

    PubMed

    Mohanty, Sanjay K; Torkelson, Andrew A; Dodd, Hanna; Nelson, Kara L; Boehm, Alexandria B

    2013-10-01

    Bioinfiltration systems facilitate the infiltration of urban stormwater into soil and reduce high flow events and flooding. Stormwater carries a myriad of pollutants including fecal indicator bacteria (FIB). Significant knowledge gaps exist about the ability of bioinfiltration systems to remove and retain FIB. The present study investigates the ability of model, simplified bioinfiltration systems containing quartz sand and iron oxide-coated quartz sand (IOCS) to remove two FIB (Enterococcus faecalis and Escherichia coli) suspended in synthetic stormwater with and without natural organic matter (NOM) as well as the potential for accumulated FIB to be remobilized during intermittent flow. The experiments were conducted in two phases: (1) the saturated columns packed with either sand or IOCS were contaminated by injecting stormwater with bacteria followed by injection of sterile stormwater and (2) the contaminated columns were subjected to intermittent infiltration of sterile stormwater preceded by a pause during which columns were either kept saturated or drained by gravity. During intermittent flow, fewer bacteria were released from the saturated column compared to the column drained by gravity: 12% of attached E. coli and 3% of attached Ent. faecalis were mobilized from the drained sand column compared to 3% of attached E. coli and 2% attached Ent. faecalis mobilized from the saturated sand column. Dry and wet cycles introduce moving air-water interfaces that can scour bacteria from grain surfaces. During intermittent flows, less than 0.2% of attached bacteria were mobilized from IOCS, which bound both bacteria irreversibly in the absence of NOM. Addition of NOM, however, increased bacterial mobilization from IOCS: 50% of attached E. coli and 8% of attached Ent. faecalis were released from IOCS columns during draining and rewetting. Results indicate that using geomedia such as IOCS that promote irreversible attachment of bacteria, and maintaining saturated condition, could minimize the mobilization of previous attached bacteria from bioinfiltration systems, although NOM may significantly decrease these benefits.

  15. Tile drainage as karst: Conduit flow and diffuse flow in a tile-drained watershed

    USGS Publications Warehouse

    Schilling, K.E.; Helmers, M.

    2008-01-01

    The similarity of tiled-drained watersheds to karst drainage basins can be used to improve understanding of watershed-scale nutrient losses from subsurface tile drainage networks. In this study, short-term variations in discharge and chemistry were examined from a tile outlet collecting subsurface tile flow from a 963 ha agricultural watershed. Study objectives were to apply analytical techniques from karst springs to tile discharge to evaluate water sources and estimate the loads of agricultural pollutants discharged from the tile with conduit, intermediate and diffuse flow regimes. A two-member mixing model using nitrate, chloride and specific conductance was used to distinguish rainwater versus groundwater inputs. Results indicated that groundwater comprised 75% of the discharge for a three-day storm period and rainwater was primarily concentrated during the hydrograph peak. A contrasting pattern of solute concentrations and export loads was observed in tile flow. During base flow periods, tile flow consisted of diffuse flow from groundwater sources and contained elevated levels of nitrate, chloride and specific conductance. During storm events, suspended solids and pollutants adhered to soil surfaces (phosphorus, ammonium and organic nitrogen) were concentrated and discharged during the rapid, conduit flow portion of the hydrograph. During a three-day period, conduit flow occurred for 5.6% of the time but accounted for 16.5% of the total flow. Nitrate and chloride were delivered primarily with diffuse flow (more than 70%), whereas 80-94% of total suspended sediment, phosphorus and ammonium were exported with conduit and intermediate flow regimes. Understanding the water sources contributing to tile drainage and the manner by which pollutant discharge occurs from these systems (conduit, intermediate or diffuse flow) may be useful for designing, implementing and evaluating non-point source reduction strategies in tile-drained landscapes. ?? 2007 Elsevier B.V. All rights reserved.

  16. Promoting nitrate removal in rain gardens

    EPA Science Inventory

    Rain gardens are vegetated surface depressions, often located at low points in landscapes, designed to receive stormwater runoff from roads, roofs, and parking lots. The gardens’ sandy soils allow stormwater to drain quickly to the native soils below and eventually to groundwate...

  17. Asymmetric underlap optimization of sub-10nm finfets for realizing energy-efficient logic and robust memories

    NASA Astrophysics Data System (ADS)

    Akkala, Arun Goud

    Leakage currents in CMOS transistors have risen dramatically with technology scaling leading to significant increase in standby power consumption. Among the various transistor candidates, the excellent short channel immunity of Silicon double gate FinFETs have made them the best contender for successful scaling to sub-10nm nodes. For sub-10nm FinFETs, new quantum mechanical leakage mechanisms such as direct source to drain tunneling (DSDT) of charge carriers through channel potential energy barrier arising due to proximity of source/drain regions coupled with the high transport direction electric field is expected to dominate overall leakage. To counter the effects of DSDT and worsening short channel effects and to maintain Ion/ Ioff, performance and power consumption at reasonable values, device optimization techniques are necessary for deeply scaled transistors. In this work, source/drain underlapping of FinFETs has been explored using quantum mechanical device simulations as a potentially promising method to lower DSDT while maintaining the Ion/ Ioff ratio at acceptable levels. By adopting a device/circuit/system level co-design approach, it is shown that asymmetric underlapping, where the drain side underlap is longer than the source side underlap, results in optimal energy efficiency for logic circuits in near-threshold as well as standard, super-threshold operating regimes. In addition, read/write conflict in 6T SRAMs and the degradation in cell noise margins due to the low supply voltage can be mitigated by using optimized asymmetric underlapped n-FinFETs for the access transistor, thereby leading to robust cache memories. When gate-workfunction tuning is possible, using asymmetric underlapped n-FinFETs for both access and pull-down devices in an SRAM bit cell can lead to high-speed and low-leakage caches. Further, it is shown that threshold voltage degradation in the presence of Hot Carrier Injection (HCI) is less severe in asymmetric underlap n-FinFETs. A lifetime projection is carried out assuming that HCI is the major degradation mechanism and it is shown that a 3.4x improvement in device lifetime is possible over symmetric underlapped n-FinFET.

  18. Westfall fiberglass bridge drain system.

    DOT National Transportation Integrated Search

    2013-03-01

    VTrans Transportation District Administrators have asked the Agencys Structures Section to consider : using nonmetallic materials in bridge drainage systems. Fiberglass is inert to oil, gas, road salt, ice : melting : solutions and many other corr...

  19. An economic perspective on Malawi's medical "brain drain".

    PubMed

    Record, Richard; Mohiddin, Abdu

    2006-12-18

    The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding.Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production") of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance) to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. There is concern about the negative impacts of the medical "brain-drain". However a closer look at the evidence for and against the medical "brain-drain" in Malawi suggests that there are potential gains in managing medical migration to produce outcomes that are beneficial to individuals, households and the country. Finally we present several policy options.

  20. An economic perspective on Malawi's medical "brain drain"

    PubMed Central

    Record, Richard; Mohiddin, Abdu

    2006-01-01

    Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production") of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance) to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a closer look at the evidence for and against the medical "brain-drain" in Malawi suggests that there are potential gains in managing medical migration to produce outcomes that are beneficial to individuals, households and the country. Finally we present several policy options. PMID:17176457

  1. Simulation of ground-water flow near the nuclear-fuel reprocessing facility at the Western New York Nuclear Service Center, Cattaraugus County, New York

    USGS Publications Warehouse

    Yager, R.M.

    1987-01-01

    A two-dimensional finite-difference model was developed to simulate groundwater flow in a surficial sand and gravel deposit underlying the nuclear fuel reprocessing facility at Western New York Nuclear Service Center near West Valley, N.Y. The sand and gravel deposit overlies a till plateau that abuts an upland area of siltstone and shale on its west side, and is bounded on the other three sides by deeply incised stream channels that drain to Buttermilk Creek, a tributary to Cattaraugus Creek. Radioactive materials are stored within the reprocessing plant and are also buried within a till deposit at the facility. Tritiated water is stored in a lagoon system near the plant and released under permit to Franks Creek, a tributary to Buttermilk Creek. Groundwater levels predicted by steady-state simulations closely matched those measured in 23 observation wells, with an average error of 0.5 meter. Simulated groundwater discharges to two stream channels and a subsurface drain were within 5% of recorded values. Steady-state simulations used an average annual recharge rate of 46 cm/yr; predicted evapotranspiration loss from the ground was 20 cm/yr. The lateral range in hydraulic conductivity obtained through model calibration was 0.6 to 10 m/day. Model simulations indicated that 33% of the groundwater discharged from the sand and gravel unit (2.6 L/sec) is lost by evapotranspiration, 3% (3.0 L/sec) flows to seepage faces at the periphery of the plateau, 20% (1.6 L/sec) discharges to stream channels that drain a large wetland area near the center of the plateau, and the remaining 8% (0.6 L/sec) discharges to a subsurface french drain and to a wastewater treatment system. Groundwater levels computed by a transient-state simulation of an annual climatic cycle, including seasonal variation in recharge and evapotranspiration, closely matched water levels measured in eight observation wells. The model predicted that the subsurface drain and the stream channel that drains the wetland would intercept most of the recharge originating near the reprocessing plant. (Lantz-PTT)

  2. Cell Adhesion Molecule and Lymphocyte Activation Marker Expression during Experimental Vaginal Candidiasis

    PubMed Central

    Wormley, Floyd L.; Chaiban, Joseph; Fidel, Paul L.

    2001-01-01

    Cell-mediated immunity by Th1-type CD4+ T cells is the predominant host defense mechanism against mucosal candidiasis. However, studies using an estrogen-dependent murine model of vaginal candidiasis have demonstrated little to no change in resident vaginal T cells during infection and no systemic T-cell infiltration despite the presence of Candida-specific systemic Th1-type responses in infected mice. The present study was designed to further investigate these observations by characterizing T-cell activation and cell adhesion molecule expression during primary and secondary C. albicans vaginal infections. While flow cytometry analysis of activation markers showed some evidence for activation of CD3+ draining lymph node and/or vaginal lymphocytes during both primary and secondary vaginal Candida infection, CD3+ cells expressing the homing receptors and integrins α4β7, αM290β7, and α4β1 in draining lymph nodes of mice with primary and secondary infections were reduced compared to results for uninfected mice. At the local level, few vaginal lymphocytes expressed integrins, with only minor changes observed during both primary and secondary infections. On the other hand, immunohistochemical analysis of vaginal cell adhesion molecule expression showed increases in mucosal addressin cell adhesion molecule 1 and vascular cell adhesion molecule 1 expression during both primary and secondary infections. Altogether, these data suggest that although the vaginal tissue is permissive to cellular infiltration during a vaginal Candida infection, the reduced numbers of systemic cells expressing the reciprocal cellular adhesion molecules may preempt cellular infiltration, thereby limiting Candida-specific T-cell responses against infection. PMID:11447188

  3. A chest drainage system with a real-time pressure monitoring device

    PubMed Central

    Liu, Tsang-Pai; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung

    2015-01-01

    Background Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the “tidaling phenomenon” in the bottle can be reflective of the extent of patient’s recovery. Objectives However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. Methods The device is made of a pressure sensor with an operating range between −100 to +100 cmH2O and an amplifying using the “Wheatstone bridge” concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. Results The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. Conclusions This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system. PMID:26380726

  4. A chest drainage system with a real-time pressure monitoring device.

    PubMed

    Chen, Chih-Hao; Liu, Tsang-Pai; Chang, Ho; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung

    2015-07-01

    Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the "tidaling phenomenon" in the bottle can be reflective of the extent of patient's recovery. However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. The device is made of a pressure sensor with an operating range between -100 to +100 cmH2O and an amplifying using the "Wheatstone bridge" concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system.

  5. Chest Drain Fall-Out Rate According to Suturing Practices: A Retrospective Direct Comparison.

    PubMed

    Asciak, Rachelle; Addala, Dinesh; Karimjee, Juzer; Rana, Maaz Suhail; Tsikrika, Stamatoula; Hassan, Maged Fayed; Mercer, Rachel Mary; Hallifax, Robert John; Wrightson, John Matthew; Psallidas, Ioannis; Benamore, Rachel; Rahman, Najib Mahboob

    2018-06-14

    Chest drains often become displaced and require replacement, adding unnecessary risks to patients. Simple measures such as suturing of the drain may reduce fall-out rates; however, there is no direct data to demonstrate this and no standardized recommended practice that is evidence based. The study aimed to analyze the rate of chest drain fall out according to suturing practice. Retrospective analysis of all chest drain insertions (radiology and pleural teams) in 2015-2016. Details of chest drain fall out were collected from patient electronic records. Drain "fall out" was pre-hoc defined as the drain tip becoming dislodged outside the pleural cavity unintentionally before a clinical decision was taken to remove the drain. A total of 369 chest drains were inserted: sutured (n = 106, 28.7%; 44 male [41.5%], median age 74 [interquartile range (IQR) 21] years), and unsutured (n = 263, 71.3%; 139 male [52.9%], median age 68 [IQR 21] years). Of the sutured drains, 7 (6.6%) fell out after a mean of 3.3 days (SD 2.6) compared to 39 (14.8%; p = 0.04) unsutured drains falling out after a mean of 2.7 days (SD 2.0; p = 0.8). Within the limits of this retrospective analysis, these results -suggest that suturing of drains is associated with lower fall-out rates. © 2018 S. Karger AG, Basel.

  6. Might digital drains speed up the time to thoracic drain removal?

    PubMed

    Afoke, Jonathan; Tan, Carol; Hunt, Ian; Zakkar, Mustafa

    2014-07-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was: might digital drains speed up the time to thoracic drain removal in terms of time till chest drain removal, hospital stay and overall cost? A total of 296 papers were identified as a result of the search as described below. Of these, five papers provided the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. A literature search revealed that several single-centre prospective randomized studies have shown significantly earlier removal of chest drains with digital drains ranging between 0.8 and 2.1 days sooner. However, there was heterogeneity in studies in the management protocol of chest drains in terms of the use of suction, number of drains and assessment for drain removal. Some protocols such as routinely keeping drains irrespective of the presence of air leak or drain output may have skewed results. Differences in exclusion criteria and protocols for discharging home with portable devices may have biased results. Due to heterogeneity in the management protocol of chest drains, there is conflicting evidence regarding hospital stay. The limited data on cost suggest that there may be significantly lower postoperative costs in the digital drain group. All the studies were single-centre series generally including patients with good preoperative lung function tests. Further larger studies with more robust chest drain management protocols are required especially to assess length of hospital stay, cost and whether the results are applicable to a larger patient population. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Trends and transformation of nutrients and pesticides in a Coastal Plain aquifer system, United States

    USGS Publications Warehouse

    Denver, J.M.; Tesoriero, A.J.; Barbaro, J.R.

    2010-01-01

    Four local-scale sites in areas with similar corn (Zea mays L.) and soybean [Glycine max (L.) Merr.] agriculture were studied to determine the effects of different hydrogeologic settings of the Northern Atlantic Coastal Plain (NACP) on the transport of nutrients and pesticides in groundwater. Settings ranged from predominantly well-drained soils overlying thick, sandy surficial aquifers to predominantly poorly drained soils with complex aquifer stratigraphy and high organic matter content. Apparent age of groundwater, dissolved gases, N isotopes, major ions, selected pesticides and degradates, and geochemical environments in groundwater were studied. Agricultural chemicals were the source of most dissolved ions in groundwater. Specific conductance was strongly correlated with reconstructed nitrate (the sum of N in nitrate and N gas) (R2 = 0.81, p < 0.0001), and is indicative of the relative degree of agricultural effects on groundwater. Trends in nitrate were primarily related to changes in manure and fertilizer use at the well-drained sites where aquifer conditions were consistently oxic. Nitrate was present in young groundwater but completely removed over time through denitrification at the poorly drained sites where there were variations in chemical input and in geochemical environment. Median concentrations of atrazine (6-chloro-N-ethyl-N'-(1- methylethyl)-1,3,5-triazine-2,4-diamine), metolachlor (2-chloro-N-(2-ethyl-6- methylphenyl)-N-(2-methoxy-1-methylethyl)acetamide), and some of their common degradates were higher at well-drained sites than at poorly drained sites, with concentrations of degradates generally higher than those of the parent compounds at all sites. An increase in the percentage of deethylatrazine to total atrazine over time at one well-drained site may be related to changes in manure application. Copyright ?? 2010 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  8. Investigation of the effects of slow-release fertilizer and struvite in biodegradation in filter drains and potential application of treated water in irrigation of road verges.

    PubMed

    Theophilus, Stephen C; Mbanaso, Fredrick U; Nnadi, Ernest O; Onyedeke, Kingsley T

    2017-11-14

    Filter drains are usually laid along the margins of highways. Highway runoffs are polluted with hydrocarbons and high levels of total dissolved solids. Therefore, effective pollution removal mechanism is necessary in order to avoid contamination of surrounding soils and groundwater. Biodegradation is amongst pollution removal mechanisms in filter drains, but it is a relatively slow process which is dependent on wide range of factors including the type of pollutant and availability of nutrients. This paper reports on a study conducted to investigate the impact of slow-release fertilizer and struvite in enhancement of biodegradation of hydrocarbon in filter drains. Filter drain models incorporated with geotextile were challenged with cumulative oil loading of 178 mg/m 2 /week with a view to comparing the efficiency of these two nutrient sources under high oil pollution loading and realistic rainfall conditions of 13 mm/week. Nutrients and street dust were applied at one-off rate of 17 g/m 2 and 1.55 g/rig to provide nutrient enhancement and simulate field conditions respectively. The impact of the nutrients was studied by monitoring bacterial and fungal growth using nutrient agar, Rose Bengal Agar media and CO2 evolution. EC, pH, heavy metals, TPH, elemental analysis and SAR were used to investigate water quality of effluent of filter drains for potential application as irrigation fluid for trees and flowers planted on road verges. The results show that nutrient application encouraged microbial activities and enhanced biodegradation rates with differences in type of nutrient applied. Also, it was observed that incorporation of geotextiles in filter drains improved pollution retention efficiency and there is a potential opportunity for utilization of struvite in SuDS systems as sustainable nutrient source.

  9. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    NASA Astrophysics Data System (ADS)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  10. Performance improvement of doped TFET by using plasma formation concept

    NASA Astrophysics Data System (ADS)

    Soni, Deepak; Sharma, Dheeraj; Yadav, Shivendra; Aslam, Mohd.; Sharma, Neeraj

    2018-01-01

    Formation of abrupt doping profile at tunneling junction for the nanoscale tunnel field effect transistor (TFET) is a critical issue for attaining improved electrical behaviour. The realization of abrupt doping profile is more difficult in the case of physically doped TFETs due to material solubility limit. In this concern, we propose a novel design of TFET. For this, P+ (source)-I (channel)-N (drain) type structure has been considered, wherein a metal electrode is deposited over the source region. In addition to this, a negative voltage is applied to the source electrode (SE). It induces the surface plasma layer of holes in the source region, which is responsible for steepness in the bands at source/channel junction and provides the advantage of higher doping in source region without any addition of the physical impurity. The proposed modification is helpful for achieving steeper band bending at the source/channel interface, which enables higher tunneling generation rate of charge carriers at this interface and overcomes the issue of low ON-state current. Thus, the proposed device shows the increment of 2 decades in drain current and 252 mV reduction in threshold voltage compared with conventional device. The optimization of spacer length (LSG) between source/gate (LSG) and applied negative voltage (Vpg) over source electrode have been performed to obtain optimum drain current and threshold voltage (Vth). Further, for the suppression of ambipolar current, drain region is kept lightly doped, which reduces the ambipolar current up to level of Off state current. Moreover, in the proposed device gate electrode is underlapped for improving RF performance. It also reduces gate to drain capacitances (Cgd) and increases cut-off-frequency (fT), fmax, GBP, TFP. In addition to these, linearity analysis has been performed to validate the applicability of the device.

  11. [Dynamic simulation analysis of effects of project of ditching for drain on Oncomelania hupensis snail control and flood prevention security in Dongting Lake region].

    PubMed

    Zheng, Zhu; Wang-Yuan, Wei; Qian-Hui, Liu; Ben-Jiao, Hu; Ze-Min, Sun

    2017-01-19

    To evaluate the effects of the project of ditching for drain on Oncomelania hupensis snail control and flood prevention security and explore the optimal engineering design plan in Dongting Lake region. A retrospective study was performed on the previous studies about the project of ditching for drain. The reference values of project indices were determined. The outside levee of Nanhu New Distinct of Yueyang City in Dongting Lake region was selected as the study area, and the cross section of marshland perpendicular to the center line of the levee was extracted to research. According to the situations of various water levels, a dynamic simulation was performed on the effect and security of the project of ditching for drain through the software FLAC 3D . The retrospective study showed that the project would be effective when the relatively subsoil water level decreased by 0.35 m, and the soil water content decreased correspondingly. The dynamic simulation by FLAC 3D showed that the minimum safe distances between transverse ditch 1, vertical ditch and levee toe should be 25 m and 13 m respectively. The digging depth of transverse ditch and vertical ditch should be 1.2 m and 1.0 m respectively. If the width of marshland in drought period was less than 500 m, one transverse ditch was efficient. Otherwise, more transverse ditches should be set with the intervals of 300 m. The project of ditching for drain is an effective ecological snail elimination method. Optimizing the digging depth of ditches and distances between transverse ditches, vertical ditch and levee toe will ensure the effects and security of the project.

  12. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and tagged indicating that... and shutoff valves connecting the dead boiler with the live system or systems shall be secured, locked, and tagged. (2) Drain connections to atmosphere on all of the dead interconnecting systems shall be...

  13. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and tagged indicating that... and shutoff valves connecting the dead boiler with the live system or systems shall be secured, locked, and tagged. (2) Drain connections to atmosphere on all of the dead interconnecting systems shall be...

  14. Drain Insertion in Chronic Subdural Hematoma: An International Survey of Practice.

    PubMed

    Soleman, Jehuda; Kamenova, Maria; Lutz, Katharina; Guzman, Raphael; Fandino, Javier; Mariani, Luigi

    2017-08-01

    To investigate whether, after the publication of grade I evidence that it reduces recurrence rates, the practice of drain insertion after burr-hole drainage of chronic subdural hematoma has changed. Further, we aimed to document various practice modalities concerning the insertion of a drain adopted by neurosurgeons internationally. We administered a survey to neurosurgeons worldwide with questions relating to the surgical treatment of chronic subdural hematoma, with an emphasis on their practices concerning the use of a drain. The preferred surgical technique was burr-hole drainage (89%). Most surgeons prefer to place a drain (80%), whereas in 56% of the cases the reason for not placing a drain was brain expansion after evacuation. Subdural drains are placed by 50% and subperiosteal drains by 27% of the responders, whereas 23% place primarily a subdural drain if possible and otherwise a subperiosteal drain. Three quarters of the responders leave the drain for 48 hours and give prophylactic antibiotic treatment, mostly a single-shot dose intraoperatively (70%). Routine postoperative computed tomography is done by 59% mostly within 24-48 hours after surgery (94%). Adjunct treatment to surgery rarely is used (4%). The publication of grade I evidence in favor of drain use influenced positively this practice worldwide. Some surgeons are still reluctant to insert a drain, especially when the subdural space is narrow after drainage of the hematoma. The insertion of a subperiosteal drain could be a good alternative solution. However, its outcome and efficacy must be evaluated in larger studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage

    PubMed Central

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Objective Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. Description We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. Methods After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at −20 cm H2O for 30 min. Results When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. Conclusion The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications. PMID:25478289

  16. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage.

    PubMed

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at -20 cm H2O for 30 min. When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications.

  17. Design of a New Acceleration System for High-Current Pulsed Proton Beams from an ECR Source

    NASA Astrophysics Data System (ADS)

    Cooper, Andrew L.; Pogrebnyak, Ivan; Surbrook, Jason T.; Kelly, Keegan J.; Carlin, Bret P.; Champagne, Arthur E.; Clegg, Thomas B.

    2014-03-01

    A primary objective for accelerators at TUNL's Laboratory for Experimental Nuclear Astrophysics (LENA) is to maximize target beam intensity to ensure a high rate of nuclear events during each experiment. Average proton target currents of several mA are needed from LENA's electron cyclotron resonance (ECR) ion source because nuclear cross sections decrease substantially at energies of interest <200 keV. We seek to suppress undesired continuous environmental background by pulsing the beam and detecting events only during beam pulses. To improve beam intensity and transport, we installed a more powerful, stable microwave system for the ECR plasma, and will install a new acceleration system. This system will: reduce defocusing effects of the beam's internal space charge; provide better vacuum with a high gas conductance accelerating column; suppress bremsstrahlung X-rays produced when backstreaming electrons strike internal acceleration tube structures; and provide better heat dissipation by using deionized water to provide the current drain needed to establish the accelerating tube's voltage gradient. Details of beam optical modeling calculations, proposed accelerating tube design, and initial beam pulsing tests will be described. Work supported in part by USDOE Office of HE and Nuclear Physics.

  18. Stainless Steel NaK-Cooled Circuit (SNaKC) Fabrication and Assembly

    NASA Technical Reports Server (NTRS)

    Godfroy, Thomas J.

    2007-01-01

    An actively pumped Stainless Steel NaK Circuit (SNaKC) has been designed and fabricated by the Early Flight Fission Test Facility (EFF-TF) team at NASA's Marshall Space Flight Center. This circuit uses the eutectic mixture of sodium and potassium (NaK) as the working fluid building upon the experience and accomplishments of the SNAP reactor program from the late 1960's The SNaKC enables valuable experience and liquid metal test capability to be gained toward the goal of designing and building an affordable surface power reactor. The basic circuit components include a simulated reactor core a NaK to gas heat exchanger, an electromagnetic (EM) liquid metal pump, a liquid metal flow meter, an expansion reservoir and a drain/fill reservoir To maintain an oxygen free environment in the presence of NaK, an argon system is utilized. A helium and nitrogen system are utilized for core, pump, and heat exchanger operation. An additional rest section is available to enable special component testing m an elevated temperature actively pumped liquid metal environment. This paper summarizes the physical build of the SNaKC the gas and pressurization systems, vacuum systems, as well as instrumentation and control methods.

  19. Reinforced-soil embankment on soft foundation.

    DOT National Transportation Integrated Search

    2001-01-01

    A section of I-670 in Columbus, OH, constructed during 1997-1998, includes a 33 ft. (l0 m) high embankment over a deposit of very soft sludge. The design used geosynthetics for reinforcement of the embankment and wick drains to accelerate the consoli...

  20. Comparison of permeable pavement types : hydrology, design, installation, maintenance and cost.

    DOT National Transportation Integrated Search

    2012-01-13

    "WisDOTs regional storm water engineer for the Southeast Region is interested in developing a park-and-ride with : porous pavement, possibly with the PaveDrain brand of permeable block. Research was needed to determine how : well permeable pavemen...

  1. Remotely-actuated biomedical switch

    NASA Technical Reports Server (NTRS)

    Lee, R. D.

    1969-01-01

    Remotely-actuated biomedical switching circuit using transistors consumes no power in the off position and can be actuated by a single-frequency telemetry pulse to control implanted instrumentation. Silicon controlled rectifiers permit the circuit design which imposes zero drain on supply batteries when not in use.

  2. Using time-dependent density functional theory in real time for calculating electronic transport

    NASA Astrophysics Data System (ADS)

    Schaffhauser, Philipp; Kümmel, Stephan

    2016-01-01

    We present a scheme for calculating electronic transport within the propagation approach to time-dependent density functional theory. Our scheme is based on solving the time-dependent Kohn-Sham equations on grids in real space and real time for a finite system. We use absorbing and antiabsorbing boundaries for simulating the coupling to a source and a drain. The boundaries are designed to minimize the effects of quantum-mechanical reflections and electrical polarization build-up, which are the major obstacles when calculating transport by applying an external bias to a finite system. We show that the scheme can readily be applied to real molecules by calculating the current through a conjugated molecule as a function of time. By comparing to literature results for the conjugated molecule and to analytic results for a one-dimensional model system we demonstrate the reliability of the concept.

  3. 3. DRAINING & DRYING BUILDING, REINFORCED CONCRETE MUSHROOM COLUMNS WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. DRAINING & DRYING BUILDING, REINFORCED CONCRETE MUSHROOM COLUMNS WITH DROP PANELS SUPPORTING DRAINING BINS (IRON VALVES OF DRAINING BINS ARE EMBEDDED IN THE CEILING), VIEW LOOKING WEST - Mill "C" Complex, Sand Draining & Drying Building, South of Dee Bennet Road, near Illinois River, Ottawa, La Salle County, IL

  4. Evisceration of Appendix through the Drain Site: A Rare Case Report.

    PubMed

    Ravishankaran, Praveen; Rajamani, A

    2013-06-01

    Placing a drain after surgery is a usual procedure in any emergency abdominal operation. The drain is removed as soon as its purpose of draining the intraabdominal collection in served. Evisceration of intraabdominal organs through the drain site is a rare occurance. This case report is about an 12 year old girl who was admitted with blunt trauma abdomen. After completion of emergency laparotomy a drain was placed in the right lower quadrant. When the drain was removed on the 6th post operative day, the appendix eviscerated out of the drain site. The wound was extended a little and an appendectomy was done. This case is presented for its rarity as only two similar instances have been reported in literature so far.

  5. A forgotten retained drain inside a knee for 10 years: A case report.

    PubMed

    Koaban, Saeed; Alatassi, Raheef; Alogayyel, Nawaf

    2018-05-29

    Surgical drains are inserted into the wound after an arthroscopic knee procedure mainly to decrease fluid collection after the operation. The use of postoperative surgical drains remains controversial. This report presents a rare case of a forgotten retained drain that was accidentally found inside a knee 10 years after an arthroscopic procedure. The drain was removed without any complications. A retained and broken drain during removal is a very rare and preventable complication that can be stressful for both the patient and surgeon. Most of the literature supports that retained drains in the soft tissues do not affect long-term outcomes, but if the drain fragment is in the intra-articular area, it might cause complications. Furthermore, there are several preventive measures to avoid retained surgical drains. By reporting this case of a forgotten drain retained inside a knee for approximately 10 years, we aim to illustrate the potential risk of leaving a drain inside the joint following an arthroscopic procedure. Furthermore, we advise that surgeons maintain a high index of suspicion for iatrogenic complications when a patient continues to complain about unexplained pain at the surgical site. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Subsurface phosphorus transport through a no-till field in the semi arid Palouse region

    NASA Astrophysics Data System (ADS)

    Norby, J. C.; Brooks, E. S.; Strawn, D. G.

    2017-12-01

    Excess application of fertilizers containing nitrogen and phosphorus for farming use has led to ongoing water quality issues in the United States. When these nutrients leave agronomic systems, and enter water bodies in large quantities, algal bloom and eutrophication can occur. Extensive studies focusing on phosphorus as a pollutant from agronomic systems have been conducted in the many regions of the United States; however, there has been a lack of studies completed in the semiarid Palouse region of eastern Washington and western Idaho. The goal of this research study was to better understand how no-till farm management has altered soil P temporally and the current availability for off-site transport of P throughout an artificially drained catchment at the Cook Agronomy Farm in Pullman, WA. We also attempted to determine the processes responsible for subsurface flow of phosphorus, specifically through preferential flow pathways. Dissolved reactive P (DRP)concentrations of subsurface drainage from a artificial drain exceeded TMDL threshold concentrations during numerous seasonal high flow events over the two-year study time frame. Soil analyses show a highly variable distribution of water-extractable P across the sub-catchment area and initial results suggest a translocation of P species deeper into the soil profile after implementing no-till practices in 1998. We hypothesized that a greater network of macropores from lack of soil disturbance allow for preferential flow of nutrient-laden water deeper into the subsurface and to the artificial drain system. Simulated flow experiments on soil cores from the study site showed large-scale macropore development, extreme variability in soil conductivity, and high P adsorption potential for the soils, suggesting a disconnect between P movement through macropore soil and subsurface drainage water rich in DRP at the artificial drain line outlet.

  7. Chest drainage systems in use

    PubMed Central

    Zisis, Charalambos; Tsirgogianni, Katerina; Lazaridis, George; Lampaki, Sofia; Baka, Sofia; Mpoukovinas, Ioannis; Karavasilis, Vasilis; Kioumis, Ioannis; Pitsiou, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Rapti, Aggeliki; Trakada, Georgia; Karapantzos, Ilias; Karapantzou, Chrysanthi; Zissimopoulos, Athanasios; Zarogoulidis, Konstantinos

    2015-01-01

    A chest tube is a flexible plastic tube that is inserted through the chest wall and into the pleural space or mediastinum. It is used to remove air in the case of pneumothorax or fluid such as in the case of pleural effusion, blood, chyle, or pus when empyema occurs from the intrathoracic space. It is also known as a Bülau drain or an intercostal catheter. Insertion of chest tubes is widely performed by radiologists, pulmonary physicians and thoracic surgeons. Large catheters or small catheters are used based on each situation that the medical doctor encounters. In the current review we will focus on the chest drain systems that are in use. PMID:25815304

  8. Nitrate concentration-drainage flow (C-Q) relationship for a drained agricultural field in Eastern North Carolina Plain

    NASA Astrophysics Data System (ADS)

    Liu, W.; Youssef, M.; Birgand, F.; Chescheir, G. M.; Maxwell, B.; Tian, S.

    2017-12-01

    Agricultural drainage is a practice used to artificially enhance drainage characteristics of naturally poorly drained soils via subsurface drain tubing or open-ditch systems. Approximately 25% of the U.S. agricultural land requires improved drainage for economic crop production. However, drainage increases the transport of dissolved agricultural chemicals, particularly nitrates to downstream surface waters. Nutrient export from artificially drained agricultural landscapes has been identified as the leading source of elevated nutrient levels in major surface water bodies in the U.S. Controlled drainage has long been practiced to reduce nitrogen export from agricultural fields to downstream receiving waters. It has been hypothesized that controlled drainage reduces nitrogen losses by promoting denitrification, reducing drainage outflow from the field, and increasing plant uptake. The documented performance of the practice was widely variable as it depends on several site-specific factors. The goal of this research was to utilize high frequency measurements to investigate the effect of agricultural drainage and related management practices on nitrate fate and transport for an artificially drained agricultural field in eastern North Carolina. We deployed a field spectrophotometer to measure nitrate concentration every 45 minutes and measured drainage flow rate using a V-notch weir every 15 minutes. Furthermore, we measured groundwater level, precipitation, irrigation amount, temperature to characterize antecedent conditions for each event. Nitrate concentration-drainage flow (C-Q) relationships generated from the high frequency measurements illustrated anti-clockwise hysteresis loops and nitrate flushing mechanism in response to most precipitation and irrigation events. Statistical evaluation will be carried out for the C-Q relationships. The results of our analysis, combined with numerical modeling, will provide a better understanding of hydrological and biogeochemical processes controlling the fate and transport of nitrate in drained agricultural landscapes.

  9. Definition and classification of chyle leak after pancreatic operation: A consensus statement by the International Study Group on Pancreatic Surgery.

    PubMed

    Besselink, Marc G; van Rijssen, L Bengt; Bassi, Claudio; Dervenis, Christos; Montorsi, Marco; Adham, Mustapha; Asbun, Horacio J; Bockhorn, Maximillian; Strobel, Oliver; Büchler, Markus W; Busch, Olivier R; Charnley, Richard M; Conlon, Kevin C; Fernández-Cruz, Laureano; Fingerhut, Abe; Friess, Helmut; Izbicki, Jakob R; Lillemoe, Keith D; Neoptolemos, John P; Sarr, Michael G; Shrikhande, Shailesh V; Sitarz, Robert; Vollmer, Charles M; Yeo, Charles J; Hartwig, Werner; Wolfgang, Christopher L; Gouma, Dirk J

    2017-02-01

    Recent literature suggests that chyle leak may complicate up to 10% of pancreatic resections. Treatment depends on its severity, which may include chylous ascites. No international consensus definition or grading system of chyle leak currently is available. The International Study Group on Pancreatic Surgery, an international panel of pancreatic surgeons working in well-known, high-volume centers, reviewed the literature and worked together to establish a consensus on the definition and classification of chyle leak after pancreatic operation. Chyle leak was defined as output of milky-colored fluid from a drain, drain site, or wound on or after postoperative day 3, with a triglyceride content ≥110 mg/dL (≥1.2 mmol/L). Three different grades of severity were defined according to the management needed: grade A, no specific intervention other than oral dietary restrictions; grade B, prolongation of hospital stay, nasoenteral nutrition with dietary restriction, total parenteral nutrition, octreotide, maintenance of surgical drains, or placement of new percutaneous drains; and grade C, need for other more invasive in-hospital treatment, intensive care unit admission, or mortality. This classification and grading system for chyle leak after pancreatic resection allows for comparison of outcomes between series. As with the other the International Study Group on Pancreatic Surgery consensus statements, this classification should facilitate communication and evaluation of different approaches to the prevention and treatment of this complication. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Reducing phosphorus loss in tile water with managed drainage in a claypan soil.

    PubMed

    Nash, Patrick R; Nelson, Kelly A; Motavalli, Peter P; Nathan, Manjula; Dudenhoeffer, Chris

    2015-03-01

    Installing subsurface tile drain systems in poorly drained claypan soils to improve corn ( L.) yields could potentially increase environmental phosphorus (P) loss through the tile drainage system. The objectives of the study were to quantify the average concentration and loss of ortho-P in tile drain water from a claypan soil and to determine whether managed subsurface drainage (MD) could reduce ortho-P loss in tile water compared with free subsurface drainage (FD). Flow-weighted ortho-P concentration in the tile water was significantly lower with MD (0.09 mg L) compared with that of FD (0.15 mg L). Ortho-P loss in the tile water of this study was reduced with MD (36 g ha) by 80% compared with FD (180 g ha). Contrary to previous research, reduced ortho-P loss observed over the 4-yr study was not solely due to the reduced amount of water drained annually (63%) with MD compared with FD. During the spring period, when flow was similar between MD and FD, the concentration of ortho-P in the tile water generally was lower with MD compared with FD, which resulted in significantly less ortho-P loss with MD. We speculate that MD's ability to conserve water during the dry summer months increased corn's uptake of water and P, which reduced the amount of P available for leaching loss in the subsequent springs. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  11. 33 CFR 183.556 - Plugs and fittings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.556 Plugs and fittings. (a) A fuel system must not have a fitting for draining fuel. (b) A plug used to service the fuel...

  12. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  13. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  14. 29 CFR 1915.163 - Ship's piping systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... are taken: (1) The isolation and shutoff valves connecting the dead system with the live system or... welded instead of bolted, at least two isolation and shutoff valves connecting the dead system with the...) Drain connections to the atmosphere on all of the dead interconnecting systems shall be opened for...

  15. 29 CFR 1915.163 - Ship's piping systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... are taken: (1) The isolation and shutoff valves connecting the dead system with the live system or... welded instead of bolted, at least two isolation and shutoff valves connecting the dead system with the...) Drain connections to the atmosphere on all of the dead interconnecting systems shall be opened for...

  16. 29 CFR 1915.162 - Ship's boilers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dead boiler with the live system or systems shall be secured, blanked, and then locked or tagged, in... the dead boiler with the live system or systems shall be secured, and then locked or tagged, in accordance with § 1915.89. (2) Drain connections to atmosphere on all of the dead interconnecting systems...

  17. 29 CFR 1915.163 - Ship's piping systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... are taken: (1) The isolation and shutoff valves connecting the dead system with the live system or... welded instead of bolted, at least two isolation and shutoff valves connecting the dead system with the...) Drain connections to the atmosphere on all of the dead interconnecting systems shall be opened for...

  18. Estimating drain flow from measured water table depth in layered soils under free and controlled drainage

    NASA Astrophysics Data System (ADS)

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-01-01

    Long records of continuous drain flow are important for quantifying annual and seasonal changes in the subsurface drainage flow from drained agricultural land. Missing data due to equipment malfunction and other challenges have limited conclusions that can be made about annual flow and thus nutrient loads from field studies, including assessments of the effect of controlled drainage. Water table depth data may be available during gaps in flow data, providing a basis for filling missing drain flow data; therefore, the overall goal of this study was to examine the potential to estimate drain flow using water table observations. The objectives were to evaluate how the shape of the relationship between drain flow and water table height above drain varies depending on the soil hydraulic conductivity profile, to quantify how well the Hooghoudt equation represented the water table-drain flow relationship in five years of measured data at the Davis Purdue Agricultural Center (DPAC), and to determine the impact of controlled drainage on drain flow using the filled dataset. The shape of the drain flow-water table height relationship was found to depend on the selected hydraulic conductivity profile. Estimated drain flow using the Hooghoudt equation with measured water table height for both free draining and controlled periods compared well to observed flow with Nash-Sutcliffe Efficiency values above 0.7 and 0.8 for calibration and validation periods, respectively. Using this method, together with linear regression for the remaining gaps, a long-term drain flow record for a controlled drainage experiment at the DPAC was used to evaluate the impacts of controlled drainage on drain flow. In the controlled drainage sites, annual flow was 14-49% lower than free drainage.

  19. Post-operative blood loss monitoring device: a new tool for nursing activities.

    PubMed

    Logier, R; Carette, D; Sozanski, J P; Jeanne, M; Jounwaz, R; De Jonckheere, J

    2012-01-01

    In most medical specialties, after surgery, it is usual to place a drain at the operative site level, in order to assist the blood flow-out if necessary. This drainage allows avoiding the formation of hematomas and contributes to tissues recovery. However, postoperative blood loss can lead to serious consequences. Also, it is necessary to continuously check the blood output volume in order to be able to intervene quickly in case of too significant losses. In daily clinical practice, this task is due to the nursing staff that periodically records the blood level inside the supple bag connected to the drain. However, this method is not accurate about the volume of lost blood and does not reflect the flow of losses which is an important parameter regarding the evolution of the patient setting. We have designed and developed a prototype of a blood loss monitoring device based on the continuous weight measurement of the blood bag connected to the drain. This device is fixed on the bed and is able to instantaneously alert the medical staff in case of abnormal blood flow-out.

  20. Carbon nanotube feedback-gate field-effect transistor: suppressing current leakage and increasing on/off ratio.

    PubMed

    Qiu, Chenguang; Zhang, Zhiyong; Zhong, Donglai; Si, Jia; Yang, Yingjun; Peng, Lian-Mao

    2015-01-27

    Field-effect transistors (FETs) based on moderate or large diameter carbon nanotubes (CNTs) usually suffer from ambipolar behavior, large off-state current and small current on/off ratio, which are highly undesirable for digital electronics. To overcome these problems, a feedback-gate (FBG) FET structure is designed and tested. This FBG FET differs from normal top-gate FET by an extra feedback-gate, which is connected directly to the drain electrode of the FET. It is demonstrated that a FBG FET based on a semiconducting CNT with a diameter of 1.5 nm may exhibit low off-state current of about 1 × 10(-13) A, high current on/off ratio of larger than 1 × 10(8), negligible drain-induced off-state leakage current, and good subthreshold swing of 75 mV/DEC even at large source-drain bias and room temperature. The FBG structure is promising for CNT FETs to meet the standard for low-static-power logic electronics applications, and could also be utilized for building FETs using other small band gap semiconductors to suppress leakage current.

  1. Reactor Simulator Testing

    NASA Technical Reports Server (NTRS)

    Schoenfeld, Michael P.; Webster, Kenny L.; Pearson, Boise J.

    2013-01-01

    As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

  2. Reactor Simulator Integration and Testing

    NASA Technical Reports Server (NTRS)

    Schoenfield, M. P.; Webster, K. L.; Pearson, J. B.

    2013-01-01

    As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator (RxSim) test loop was designed and built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing were to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V because the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This Technical Memorandum summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained, which was lower than the predicted 750 K but 156 K higher than the cold temperature, indicating the design provided some heat regeneration. The annular linear induction pump tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

  3. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  4. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  5. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  6. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  7. Impact of methicillin-resistant Staphylococcus Aureus (MRSA) infection on patient outcome after pancreatoduodenectomy (PD)--a cause for concern?

    PubMed

    Sanjay, Pandanaboyana; Fawzi, Ali; Kulli, Christoph; Polignano, Francesco M; Tait, Iain S

    2010-11-01

    This study evaluated the impact of methicillin-resistant Staphylococcus aureus (MRSA) hospital-acquired infection on postoperative complications and patient outcome after pancreatoduodenectomy (PD). Seventy-nine patients who underwent PD were monitored for hospital-acquired MRSA. The patients were grouped as (1) no MRSA infection, (2) skin colonization with MRSA, and (3) systemic MRSA infection. Forty (51%) of the 79 patients were MRSA positive during hospital admission. Fourteen of the 40 patients swabbed for MRSA were found positive (skin colonization), and 26 patients (33%) developed systemic MRSA infection after PD. The sites of MRSA infection included (1) abdominal drain fluid (16/26; 42%), (2) sputum (4/26; 15%), (3) blood cultures (2/26; 8%), and (4) combination of sites (9/26; 35%). The patients with systemic MRSA infection had a longer postoperative stay (31 vs 22 days; P = 0.005) and increased incidence of chest infections compared with MRSA-negative patients (14 vs 4; P = 0.02). Four of the 16 patients with MRSA-positive drain fluid had a postpancreatectomy hemorrhage compared with 3 of the 63 patients with no MRSA infection in drain fluid (P = 0.02). Of the 79 patients admitted for PD, 51% became colonized with MRSA infection. Systemic hospital-acquired MRSA infection in 33% was associated with prolonged postoperative stay, increased wound and chest infections, and increased risk of postoperative hemorrhage.

  8. Ranger Station Solar-Energy System Receives Economic Evaluation

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Economic performance of Glendo Reservoir Ranger Station solar-energy system in Wyoming and extrapolated performance in four other locations around the U.S. is reviewed in report. System is a passive drain-down system using water as heat-transfer medium for space and hot-water heating.

  9. Bacterial diversity of floor drain biofilms and drain waters in a Listeria monocytogenes contaminated food processing environment.

    PubMed

    Dzieciol, Monika; Schornsteiner, Elisa; Muhterem-Uyar, Meryem; Stessl, Beatrix; Wagner, Martin; Schmitz-Esser, Stephan

    2016-04-16

    Sanitation protocols are applied on a daily basis in food processing facilities to prevent the risk of cross-contamination with spoilage organisms. Floor drain water serves along with product-associated samples (slicer dust, brine or cheese smear) as an important hygiene indicator in monitoring Listeria monocytogenes in food processing facilities. Microbial communities of floor drains are representative for each processing area and are influenced to a large degree by food residues, liquid effluents and washing water. The microbial communities of drain water are steadily changing, whereas drain biofilms provide more stable niches. Bacterial communities of four floor drains were characterized using 16S rRNA gene pyrosequencing to better understand the composition and exchange of drain water and drain biofilm communities. Furthermore, the L. monocytogenes contamination status of each floor drain was determined by applying cultivation-independent real-time PCR quantification and cultivation-dependent detection according to ISO11290-1. Pyrosequencing of 16S rRNA genes of drain water and drain biofilm bacterial communities yielded 50,611 reads, which were clustered into 641 operational taxonomic units (OTUs), affiliated to 16 phyla dominated by Proteobacteria, Firmicutes and Bacteroidetes. The most abundant OTUs represented either product- (Lactococcus lactis) or fermentation- and food spoilage-associated phylotypes (Pseudomonas mucidolens, Pseudomonas fragi, Leuconostoc citreum, and Acetobacter tropicalis). The microbial communities in DW and DB samples were distinct in each sample type and throughout the whole processing plant, indicating the presence of indigenous specific microbial communities in each processing compartment. The microbiota of drain biofilms was largely different from the microbiota of the drain water. A sampling approach based on drain water alone may thus only provide reliable information on planktonic bacterial cells but might not allow conclusions on the bacterial composition of the microbiota in biofilms. Copyright © 2016. Published by Elsevier B.V.

  10. [Outpatient Drain Management in Patients with Clinically Relevant Postoperative Pancreatic Fistula (CR-POPF) - Current Status in Germany].

    PubMed

    Hempel, Sebastian; Püttmann, Pamela; Kahlert, Christoph; Seifert, Lena; Mees, Sören Torge; Welsch, Thilo; Weitz, Jürgen; Distler, Marius

    2018-06-01

    Postoperative pancreatic fistula (POPF) is a common complication after pancreatic surgery and is associated with extended hospitalisation, increased medical costs, and reduced quality of life. The aim of the present study was to assess the treatment of POPF in Germany, with a special focus on outpatient drain management in patients with clinically relevant POPF (CR-POPF). A questionnaire evaluating postoperative management once a CR-POPF is diagnosed - especially focusing on ambulatory drain management - was developed and sent to 211 German hospitals performing > 12 pancreatic operations per year. Statistical analysis was carried out using SPSS 21. The final response rate was 62% (n = 131). Outpatient drainage management is performed by most of the responding hospitals (n = 100, 76.3%). However, 30% of hospitals (n = 40) perform outpatient treatment only in 5% of their cases with clinically relevant POPF. There was no correlation between case load of the pancreatic centres and frequency of outpatient drain management. In general, discharge criteria for patients with drained POPF (n = 98, 74.8%), the drain management itself (n = 95, 72.5%) and criteria for drain removal (n = 74, 56.5%) are not standardised but made individually. In centres with standardised drain management criteria for drain removal, these criteria were drain volume < 20 ml (29.8%), no fluid collection (25.2%), no elevation of drain amylase/lipase (25.2%) and no specific symptoms (22.1%). This is the first survey in Germany evaluating outpatient drain management in patients with CR-POPF. Although the data in the literature are rare, the majority of German pancreatic surgeons perform outpatient drain management. However, discharge criteria, outpatient care and drain removal are standardised in only the minority of centres. Therefore, we recommend the evaluation of discharge criteria and a management algorithm for patients with drained CR-POPF to improve the perioperative course. Georg Thieme Verlag KG Stuttgart · New York.

  11. Velocity control propulsion subsystem of the Radio Astronomy Explorer satellite for Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Braught, W.; Moore, E. K.; Steinberg, R. L.

    1973-01-01

    The Velocity Control Propulsion Subsystem (VCPS) was designed the propulsion required for trajectory and lunar orbit corrections of the spacecraft. A GFE clamp assembly physically attaches the VCPS to the spacecraft and the unit is ejected after completing the required corrections. The VCPS is physically and functionally separated from the spacecraft except for the electrical and telemetry interfaces. A GFE transtage provides the superstructure on which the VCPS is assembled. The subsystem consists of two 5 foot pound rocket engine assemblies, 4 propellant tanks, 2 latching valves, 2 fill and drain valves, a system filter, pressure transducer, gas and propellant manifolds and electrical heaters and thermostats. The RAE-B VCPS program covered the design, manufacture and qualification of one subsystem. This subsystem was to be manufactured, subjected to qualification tests; and refurbished, if necessary, prior to flight. The VCPS design and test program precluded the need for refurbishing the subsystem and the unit was delivered to GSFC at the conclusion of the program.

  12. Partial abnormal drainage of superior and inferior caval veins into the left atrium: two case reports.

    PubMed

    Chessa, Massimo; Carminati, Mario; Cinteză, Eliza Elena; Butera, Gianfranco; Giugno, Luca; Arcidiacono, Carmelo; Piazza, Luciane; Bulescu, Nicolae Cristian; Pome, Giuseppe; Frigiola, Alessandro; Giamberti, Alessandro

    2016-01-01

    Abnormal connection of the right superior caval vein to the left atrium is an uncommon systemic vein drainage anomaly, with only a few cases reported among congenital heart disease (CHD), around 20 cases published in the medical literature. The inferior vena cava connection with the left atrium, also very rare, can appear directly or in heterotaxy. Clinical suspicion arises due to the presence of cyanosis in the absence of other specific clinical signs (without other associated CHD). We present the cases of two children with abnormal superior and inferior systemic venous return. The first case is an abnormal connection of right superior vena cava to the left atrium associated with persistent left superior vena cava draining into the right atrium through the coronary sinus. The second case is an interruption of the inferior vena cava with hemiazygos continuation, drained into the left superior vena cava, which drained into the left atrium. The diagnosis was imagistic - echocardiography and angiography. Surgical treatment solutions vary from one case to another, usually following anatomic correction. Hypoxia accompanied by cyanosis must bring into question the pathology of systemic venous drainage anomaly, after other common causes have been excluded. Surgery is indicated in all cases due to the risk associated with the presence of right-to-left shunt.

  13. Drivers of variability in tree transpiration in a Boreal Black Spruce Forest Chronosequence

    NASA Astrophysics Data System (ADS)

    Angstmann, J. L.; Ewers, B. E.; Kwon, H.

    2009-12-01

    Boreal forests are of particular interest in climate change studies because of their large land area and ability to sequester and store carbon, which is controlled by water availability. Heterogeneity of these forests is predicted to increase with climate change through the impact of more frequent wildfires, warmer, longer growing seasons, and potential drainage of forested wetlands. This study aims to quantify the influence of stand age, drainage condition, and species on tree transpiration and its drivers in a central Canadian black spruce boreal forest. Heat dissipation sensors were installed in 113 trees (69 Picea mariana (black spruce), 25 Populus tremuloides (trembling aspen), and 19 Pinus banksiana (jack pine) at four stand ages, each containing a well- and poorly-drained site over three growing seasons (2006-2008). Sap flux per unit xylem area, JS, was expressed as transpiration per unit ground area, EC, and transpiration per unit leaf area, EL, using site- and species-specific allometry to obtain sapwood area (AS)and leaf area(AL)per unit ground area. Well-drained, younger Picea mariana daily JS was 47-64% greater than the older well-drained burn ages and younger poorly-drained stands were 64-68% greater than the two oldest poorly-drained stands. Daily EL in the well-drained Picea mariana stands was on average 12-33% higher in younger stand than in the two oldest stands whereas young, poorly-drained Picea mariana had 71% greater daily EL than the older stands. Well-drained Picea mariana trees had 52% higher daily EC than older trees and poorly-drained Picea mariana in the 1964 burn had 42-81% higher daily EC than the oldest stands. Populus tremuloides located in the two youngest stands had daily JS 38-58% greater rates than the 1930 burn, whereas daily EL and EC had no distint differences due to high interannual variability. Pinus banksiana experienced 21-33% greater daily JS in the 1989 burn than in the older 1964 burn for well- and poorly-drained sites. Poorly-drained Pinus banksiana trees from the older 1964 burn had 23-48% greater daily EL and 26-39% higher daily EC than the 1989 burn. Poorly-drained Picea mariana had 17-31% higher daily JS than the well-drained sites. Poorly-drained Picea mariana had 29-58% higher daily EL 42-50% higher daily EC than the well-drained trees. Poorly-drained Pinus banksiana on average had 27-28% higher daily JS than well-drained trees. Poorly-drained Pinus banskiana had 23.25% higher daily EL than well-drained trees and daily EC 32-67% lower than the well-drained trees. Drivers of these differences include midday leaf water potential, AS, and AL.

  14. Electric current focusing efficiency in a graphene electric lens.

    PubMed

    Mu, Weihua; Zhang, Gang; Tang, Yunqing; Wang, Wei; Ou-Yang, Zhongcan

    2011-12-14

    In the present work, we study theoretically the electron wave's focusing phenomenon in a single-layered graphene pn junction (PNJ) and obtain the electric current density distribution of graphene PNJ, which is in good agreement with the qualitative result in previous numerical calculations (Cheianov et al 2007 Science, 315, 1252). In addition, we find that, for a symmetric PNJ, 1/4 of total electric current radiated from the source electrode can be collected by the drain electrode. Furthermore, this ratio reduces to 3/16 in a symmetric graphene npn junction. Our results obtained by the present analytical method provide a general design rule for an electric lens based on negative refractory index systems. © 2011 IOP Publishing Ltd

  15. Reinforced-soil embankment on soft foundation : executive summary.

    DOT National Transportation Integrated Search

    2000-01-01

    A section of I-670 in Columbus, OH, constructed during 1997-1998, includes a 33 ft. (l0 m) high embankment over a deposit of very soft sludge. The design used geosynthetics for reinforcement of the embankment and wick drains to accelerate the consoli...

  16. Blind inlets: Conservation practices to reduce herbicide losses from closed depressional areas

    USDA-ARS?s Scientific Manuscript database

    Pesticides are designed to benefit agricultural production and may inadvertently affect water quality if environmental stewardship programs are not implemented. Closed depressional areas (potholes) are typical in the US Midwest and are usually drained with tile risers, however sediment and contamina...

  17. Generating enhanced site topography data to improve permeable pavement performance assessment methods - presentation

    EPA Science Inventory

    Permeable pavement surfaces are infiltration based stormwater control measures (SCM) commonly applied in parking lots to decrease impervious area and reduce runoff volume. Many are not optimally designed however, as little attention is given to draining a large enough contributin...

  18. Analytical drain current model for symmetric dual-gate amorphous indium gallium zinc oxide thin-film transistors

    NASA Astrophysics Data System (ADS)

    Qin, Ting; Liao, Congwei; Huang, Shengxiang; Yu, Tianbao; Deng, Lianwen

    2018-01-01

    An analytical drain current model based on the surface potential is proposed for amorphous indium gallium zinc oxide (a-InGaZnO) thin-film transistors (TFTs) with a synchronized symmetric dual-gate (DG) structure. Solving the electric field, surface potential (φS), and central potential (φ0) of the InGaZnO film using the Poisson equation with the Gaussian method and Lambert function is demonstrated in detail. The compact analytical model of current-voltage behavior, which consists of drift and diffusion components, is investigated by regional integration, and voltage-dependent effective mobility is taken into account. Comparison results demonstrate that the calculation results obtained using the derived models match well with the simulation results obtained using a technology computer-aided design (TCAD) tool. Furthermore, the proposed model is incorporated into SPICE simulations using Verilog-A to verify the feasibility of using DG InGaZnO TFTs for high-performance circuit designs.

  19. A compact model and direct parameters extraction techniques For amorphous gallium-indium-zinc-oxide thin film transistors

    NASA Astrophysics Data System (ADS)

    Moldovan, Oana; Castro-Carranza, Alejandra; Cerdeira, Antonio; Estrada, Magali; Barquinha, Pedro; Martins, Rodrigo; Fortunato, Elvira; Miljakovic, Slobodan; Iñiguez, Benjamin

    2016-12-01

    An advanced compact and analytical drain current model for the amorphous gallium indium zinc oxide (GIZO) thin film transistors (TFTs) is proposed. Its output saturation behavior is improved by introducing a new asymptotic function. All model parameters were extracted using an adapted version of the Universal Method and Extraction Procedure (UMEM) applied for the first time for GIZO devices in a simple and direct form. We demonstrate the correct behavior of the model for negative VDS, a necessity for a complete compact model. In this way we prove the symmetry of source and drain electrodes and extend the range of applications to both signs of VDS. The model, in Verilog-A code, is implemented in Electronic Design Automation (EDA) tools, such as Smart Spice, and compared with measurements of TFTs. It describes accurately the experimental characteristics in the whole range of GIZO TFTs operation, making the model suitable for the design of circuits using these types of devices.

  20. RAMI Analysis for Designing and Optimizing Tokamak Cooling Water System (TCWS) for the ITER's Fusion Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrada, Juan J; Reiersen, Wayne T

    U.S.-ITER is responsible for the design, engineering, and procurement of the Tokamak Cooling Water System (TCWS). TCWS is designed to provide cooling and baking for client systems that include the first wall/blanket, vacuum vessel, divertor, and neutral beam injector. Additional operations that support these primary functions include chemical control of water provided to client systems, draining and drying for maintenance, and leak detection/localization. TCWS interfaces with 27 systems including the secondary cooling system, which rejects this heat to the environment. TCWS transfers heat generated in the Tokamak during nominal pulsed operation - 850 MW at up to 150 C andmore » 4.2 MPa water pressure. Impurities are diffused from in-vessel components and the vacuum vessel by water baking at 200-240 C at up to 4.4 MPa. TCWS is complex because it serves vital functions for four primary clients whose performance is critical to ITER's success and interfaces with more than 20 additional ITER systems. Conceptual design of this one-of-a-kind cooling system has been completed; however, several issues remain that must be resolved before moving to the next stage of the design process. The 2004 baseline design indicated cooling loops that have no fault tolerance for component failures. During plasma operation, each cooling loop relies on a single pump, a single pressurizer, and one heat exchanger. Consequently, failure of any of these would render TCWS inoperable, resulting in plasma shutdown. The application of reliability, availability, maintainability, and inspectability (RAMI) tools during the different stages of TCWS design is crucial for optimization purposes and for maintaining compliance with project requirements. RAMI analysis will indicate appropriate equipment redundancy that provides graceful degradation in the event of an equipment failure. This analysis helps demonstrate that using proven, commercially available equipment is better than using custom-designed equipment with no field experience and lowers specific costs while providing higher reliability. This paper presents a brief description of the TCWS conceptual design and the application of RAMI tools to optimize the design at different stages during the project.« less

  1. Brain drain and health workforce distortions in Mozambique.

    PubMed

    Sherr, Kenneth; Mussa, Antonio; Chilundo, Baltazar; Gimbel, Sarah; Pfeiffer, James; Hagopian, Amy; Gloyd, Stephen

    2012-01-01

    Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs), and the private sector. An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties. Of 723 qualifying physicians between 1980-2006, 95.9% (693) were working full-time, including 71.1% (493) as clinicians, 20.5% (142) as health system managers, and 6.9% (48) as researchers/professors. 25.5% (181) of the sample had left the public sector, of which 62.4% (113) continued working in-country and 37.6% (68) emigrated from Mozambique. Of those cases of internal migration, 66.4% (75) worked for NGOs, 21.2% (24) for donor agencies, and 12.4% (14) in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113) of internal migration cases had previously held senior-level management positions in the public sector. Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they seek to strengthen.

  2. Brain Drain and Health Workforce Distortions in Mozambique

    PubMed Central

    Sherr, Kenneth; Mussa, Antonio; Chilundo, Baltazar; Gimbel, Sarah; Pfeiffer, James; Hagopian, Amy; Gloyd, Stephen

    2012-01-01

    Introduction Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs), and the private sector. Methods An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980–2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties. Results Of 723 qualifying physicians between 1980–2006, 95.9% (693) were working full-time, including 71.1% (493) as clinicians, 20.5% (142) as health system managers, and 6.9% (48) as researchers/professors. 25.5% (181) of the sample had left the public sector, of which 62.4% (113) continued working in-country and 37.6% (68) emigrated from Mozambique. Of those cases of internal migration, 66.4% (75) worked for NGOs, 21.2% (24) for donor agencies, and 12.4% (14) in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113) of internal migration cases had previously held senior-level management positions in the public sector. Discussion Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they seek to strengthen. PMID:22558237

  3. Controlling the ambipolarity and improvement of RF performance using Gaussian Drain Doped TFET

    NASA Astrophysics Data System (ADS)

    Nigam, Kaushal; Gupta, Sarthak; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2018-05-01

    Ambipolar conduction in tunnel field-effect transistors (TFETs) has been occurred as an inherent issue due to drain-channel tunneling. It makes TFET less efficient and restricts its application in complementary digital circuits. Therefore, this manuscript reports the application of Gaussian doping profile on nanometer regime silicon channel TFETs to completely eliminate the ambipolarity. For this, Gaussian doping is used in the drain region of conventional gate-drain overlap TFET to control the tunneling of electrons from the valence band of channel to the conduction band of drain. As a result, barrier width at the drain/channel junction increases significantly leading to the suppression of an ambipolar current even when higher doping concentration (1 ? 10 ? cm ?) is considered in the drain region. However, significant improvement in terms of RF figure-of-merits such as cut-off frequency (f ?), gain bandwidth product (GBW), and gate-to-drain capacitance (C ?) is achieved with Gaussian doped gate on drain overlap TFET as compared to its counterpart TFET.

  4. Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion

    PubMed Central

    Rotman, Jessica A.; Getrajdman, George I.; Maybody, Majid; Erinjeri, Joseph P.; Yarmohammadi, Hooman; Sofocleous, Constantinos T.; Solomon, Stephen B.; Boas, F. Edward

    2016-01-01

    Background The purpose of this study is to determine whether larger abdominopelvic abscess drains reduce the time required for abscess resolution, or the probability of tube occlusion. Methods 144 consecutive patients who underwent abscess drainage at a single institution were reviewed retrospectively. Results: Larger initial drain size did not reduce drainage time, drain occlusion, or drain exchanges (p>0.05). Subgroup analysis did not find any type of collection that benefitted from larger drains. A multivariate model predicting drainage time showed that large collections (>200 ml) required 16 days longer drainage time than small collections (<50 ml). Collections with a fistula to bowel required 17 days longer drainage time than collections without a fistula. Initial drain size and the viscosity of the fluid in the collection had no significant effect on drainage time in the multivariate model. Conclusions 8 F drains are adequate for initial drainage of most serous and serosanguineous collections. 10 F drains are adequate for initial drainage of most purulent or bloody collections. PMID:27634422

  5. Decommissioning of the 247-F Fuel Manufacturing Facility at the Savannah River Site (SRS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos, Joseph K.; Chostner, Stephen M.

    Building 247-F at SRS was a roughly 110,000 ft{sup 2} two-story facility designed and constructed during the height of the cold war naval buildup to provide additional naval nuclear fuel manufacturing capacity in early 1980's. The manufacturing process employed a wide variety of acids, bases, and other hazardous materials. As the need for naval fuel declined, the facility was shut down and underwent initial deactivation, which was completed in 1990. All process systems were flushed with water and drained using the existing process drain valves. However, since these drains were not always installed at the lowest point in piping andmore » equipment systems, a significant volume of liquid remained after initial deactivation. After initial deactivation, a non-destructive assay of the process area identified approximately 17 ({+-}100%) kg of uranium held up in equipment and piping. The facility was placed in Surveillance and Maintenance mode until 2003, when the decision was made to perform final deactivation, and then decommission the facility. The following lessons were learned as a result of the D and D of building 247-F. Successful D and D of a major radiochemical process building requires significant up-front planning by a team of knowledgeable personnel led by a strong project manager. The level of uncertainty and resultant risk to timely, cost effective project execution was found to be high. Examples of the types of problems encountered which had high potential to adversely impact cost and schedule performance are described below. Low level and sanitary waste acceptance criteria do not allow free liquids in waste containers. These liquids, which are often corrosive, must be safely removed from the equipment before it is loaded to waste containers. Drained liquids must be properly managed, often as hazardous or mixed waste. Tapping and draining of process lines is a dangerous operation, which must be performed carefully. The temptation to become complacent when breaking into lines is great. Incidents of personnel exposure to liquids during draining are likely. Records from the initial 1990 deactivation led early work planners to assume the facility was cold, dark and dry. This turned out to be a poor assumption. Work instructions had to be modified to require that engineers evaluate each of several hundred process lines to identify the low point, where a tap and drain system could be installed to allow positive verification that the line was empty before the line was cut for removal. During the period between facility shut down in 1990 and the start of final deactivation in 2003, roof leaks had developed, allowing rain water to enter building 247-F, which provided an environment for mold growth. Sampling confirmed the presence of Stachybotrys chartarum, a toxic indoor mold that grows on wet cellulosic material, such as drywall paper. D and D workers in areas where this hazard was identified were required to where proper personal protective equipment, which complicated work execution. Discovery of the potential presence of uniquely hazardous chemicals such as shock sensitive compounds and toxic uranium hexafluoride became issues which required investigation and special handling strategies. Team access to subject matter experts, who could quickly provide the required guidance for safe material handling, was critical to keeping the project on schedule. In old legacy facilities, it is possible that the D and D workers will be exposed to undocumented energy sources such as energized electrical conductors and pipes containing hazardous materials that originate outside the boundaries of the facility. Significant effort must be expended on adequate mechanical and electrical isolation. Subdividing the facility into well defined zones for which detailed zone-specific end points could be developed proved to be a highly effective project management strategy. Waste management must be carefully planned. The rate of waste generation as the facility is converted from a structure to waste can frequently exceed the D and D team's resources to characterize, package, store and transport the waste to a disposal facility in a timely manner. This can lead to schedule delays and/or increased project cost.« less

  6. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    PubMed Central

    2010-01-01

    Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery. PMID:20492665

  7. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    PubMed

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  8. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    PubMed

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  9. Long-Term Hydrologic Impacts of Controlled Drainage Using DRAINMOD

    NASA Astrophysics Data System (ADS)

    Saadat, S.; Bowling, L. C.; Frankenberger, J.

    2017-12-01

    Controlled drainage is a management strategy designed to mitigate water quality issues caused by subsurface drainage but it may increase surface ponding and runoff. To improve controlled drainage system management, a long-term and broader study is needed that goes beyond the experimental studies. Therefore, the goal of this study was to parametrize the DRAINMOD field-scale, hydrologic model for the Davis Purdue Agricultural Center located in Eastern Indiana and to predict the subsurface drain flow and surface runoff and ponding at this research site. The Green-Ampt equation was used to characterize the infiltration, and digital elevation models (DEMs) were used to estimate the maximum depressional storage as the surface ponding parameter inputs to DRAINMOD. Hydraulic conductivity was estimated using the Hooghoudt equation and the measured drain flow and water table depths. Other model inputs were either estimated or taken from the measurements. The DRAINMOD model was calibrated and validated by comparing model predictions of subsurface drainage and water table depths with field observations from 2012 to 2016. Simulations based on the DRAINMOD model can increase understanding of the environmental and hydrological effects over a broader temporal and spatial scale than is possible using field-scale data and this is useful for developing management recommendations for water resources at field and watershed scales.

  10. A Distance Detector with a Strip Magnetic MOSFET and Readout Circuit.

    PubMed

    Sung, Guo-Ming; Lin, Wen-Sheng; Wang, Hsing-Kuang

    2017-01-10

    This paper presents a distance detector composed of two separated metal-oxide semiconductor field-effect transistors (MOSFETs), a differential polysilicon cross-shaped Hall plate (CSHP), and a readout circuit. The distance detector was fabricated using 0.18 μm 1P6M Complementary Metal-Oxide Semiconductor (CMOS) technology to sense the magnetic induction perpendicular to the chip surface. The differential polysilicon CSHP enabled the magnetic device to not only increase the magnetosensitivity but also eliminate the offset voltage generated because of device mismatch and Lorentz force. Two MOSFETs generated two drain currents with a quadratic function of the differential Hall voltages at CSHP. A readout circuit-composed of a current-to-voltage converter, a low-pass filter, and a difference amplifier-was designed to amplify the current difference between two drains of MOSFETs. Measurements revealed that the electrostatic discharge (ESD) could be eliminated from the distance sensor by grounding it to earth; however, the sensor could be desensitized by ESD in the absence of grounding. The magnetic influence can be ignored if the magnetic body (human) stays far from the magnetic sensor, and the measuring system is grounded to earth by using the ESD wrist strap (Strap E-GND). Both 'no grounding' and 'grounding to power supply' conditions were unsuitable for measuring the induced Hall voltage.

  11. In Situ NDA Conformation Measurements Performed at Auxiliary Charcoal Bed and Other Main Charcoal Beds After Uranium Removal from Molten Salt Reactor Experiment ACB at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haghighi, M. H.; Kring, C. T.; McGehee, J. T.

    2002-02-26

    The Molten Salt Reactor Experiment (MSRE) site is located in Tennessee, on the U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR). The MSRE was run by Oak Ridge National Laboratory (ORNL) to demonstrate the desirable features of the molten-salt concept in a practical reactor that could be operated safely and reliably. It introduced the idea of a homogeneous reactor using fuel salt media and graphite moderation for power and breeder reactors. The MSRE reactor and associated components are located in cells beneath the floor in the high-bay area of Building 7503. The reactor was operated from June 1965 tomore » December 1969. When the reactor was shut down, fuel salt was drained from the reactor circuit to two drain tanks. A ''clean'' salt was then circulated through the reactor as a decontamination measure and drained to a third drain tank. When operations ceased, the fuel and flush salts were allowed to cool and solidify in the drain tanks. At shutdown, the MSRE facility complex was placed in a surveillance and maintenance program. Beginning in 1987, it was discovered that gaseous uranium (U-233/U-232) hexafluoride (UF6) had moved throughout the MSRE process systems. The UF6 had been generated when radiolysis in the fluorine salts caused the individual constituents to dissociate to their component atoms, including free fluorine. Some of the free fluorine combined with uranium fluorides (UF4) in the salt to produce UF6. UF6 is gaseous at slightly above ambient temperatures; thus, periodic heating of the fuel salts (which was intended to remedy the radiolysis problems) and simple diffusion had allowed the UF6 to move out of the salt and into the process systems of MSRE. One of the systems that UF6 migrated into due to this process was the offgas system which is vented to the MSRE main charcoal beds and MSRE auxiliary charcoal bed (ACB). Recently, the majority of the uranium laden-charcoal material residing within the ACB was safely and successfully removed using the uranium deposit removal system and equipment. After removal a series of NDA measurements was performed to determine the amount of uranium material remaining in the ACB, the amount of uranium material removed from the ACB, and the amount of uranium material remaining in the uranium removal equipment due to removal activities.« less

  12. Influence of the renal lower pole anatomy and mid-renal-zone classification in successful approach to the calices during flexible ureteroscopy.

    PubMed

    Marroig, Bruno; Frota, Rodrigo; Fortes, Marco A; Sampaio, Francisco J; Favorito, Luciano Alves

    2016-04-01

    The aim of this paper is to analyze if the anatomy type of the collector system (CS) limits the accessibility of flexible ureteroscopy (FUR) in the lower pole. We analyzed the pyelographies of 51 patients submitted to FUR and divided the CS into four groups: A1-kidney midzone (KM) drained by minor calices (Mc) that are dependent on the superior or on the inferior caliceal groups; A2-KM drained by crossed calices; B1-KM drained by a major caliceal group independent both of the superior and inferior groups, and B2-KM drained by Mc entering directly into the renal pelvis. We studied the number of calices, the angle between the lower infundibulum and renal pelvis, and the angle between the lower infundibulum and the inferior Mc. With the use of a flexible ureteroscope, the access attempt was made to all of lower pole calices. Averages were statistically compared using the ANOVA and Unpaired T test (p < 0.05). We found 14 kidneys of A1 (27.45 %); 4 of A2 (7.84 %); 17 of B1 (33.33 %); and 16 of B2 (31.37 %). The LIP was >90° in 31 kidneys (60.78 %) and between 61° and 90° in 20 kidneys (39.22 %). We did not find angles smaller than 60°. The group A1 presented 48 Mc and the UF was able to access 42 (87.5 %); the group A2 had 11 Mc and the UF was able to access 7 (63.64 %); the group B1 had 48 Mc and the UF was able to access 41 (85.42 %) and in group B2 we observed 41 Mc and the UF could access 35 (85.36 %). There was no statistical difference in the accessibility between the groups (p = 0.2610). Collecting system with kidney midzone drained by crossed calices presented the lower accessibility rate during FUR.

  13. Advances in Dust Detection and Removal for Tokamaks

    NASA Astrophysics Data System (ADS)

    Campos, A.; Skinner, C. H.; Roquemore, A. L.; Leisure, J. O. V.; Wagner, S.

    2008-11-01

    Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. An electrostatic dust detector[1] developed in the laboratory is being applied to NSTX. In the tokamak environment, large particles or fibres can fall on the grid potentially causing a permanent short. We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments with varying nozzle designs, backing pressures, puff durations, and exit flow orientations have obtained an optimal configuration that effectively removes particles from a 25 cm^2 area. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tripolar grid of fine interdigitated traces has been designed that generates an electrostatic travelling wave for conveying dust particles to a ``drain.'' First trials have shown particle motion in optical microscope images. [1] C. H. Skinner et al., J. Nucl. Mater., 376 (2008) 29.

  14. A programmable point-of-care device for external CSF drainage and monitoring.

    PubMed

    Simkins, Jeffrey R; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.

  15. An elevated source/drain-on-insulator structure to maximize the intrinsic performance of extremely scaled MOSFETs

    NASA Astrophysics Data System (ADS)

    Zhang, Zhikuan; Zhang, Shengdong; Feng, Chuguang; Chan, Mansun

    2003-10-01

    In this paper, a source/drain structure separated from the silicon substrate by oxide isolation is fabricated and studied. The source/drain diffusion regions are connected to the shallow source/drain extension through a smaller opening defined by a double spacer process. Experimental results indicate that the source/drain on insulator significantly reduces the parasitic capacitance. Further optimization by simulation indicates a reduction of series resistance and band-to-band drain leakage at off-state can be achieved in extremely scaled devices. Compared with the conventional planner source/drain structure, the reduction of parasitic capacitance and series resistance can be as much as 80% and 30% respectively.

  16. Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.

    PubMed

    Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2017-04-07

    The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.

  17. Camel Gate Field Effect Transistors.

    DTIC Science & Technology

    1983-01-01

    CAMFETs can be designed to yield relatively voltage independent transconductances, large for- * ward turn-on voltages, and large gate-drain breakdown...doping. The FATFET area is 4.6 x 10- 4 cm2. I.- . - . . - , - 36 80 * Camel Gate U_-- Eperimental 60 * -Theoretical % Schottky Gate ~--Experimental CL 4...in the design of other devices. Finally, a comparative study of the reliabil- ities of CAMFETs, JFETs, and MESFETs should be attempted. 43 VII

  18. Microanatomy of the intestinal lymphatic system

    PubMed Central

    Miller, Mark J.; Newberry, Rodney D.

    2011-01-01

    The intestinal lymphatic system is comprised of two non-communicating lymphatic networks; one containing the lacteals draining the villi and the connecting submucosal lymphatic network, and one containing the lymphatics that drain the intestine muscular layer. These systems deliver lymph into a common network of collecting lymphatics originating near the mesenteric border. The intestinal lymphatic system serves vital functions in the regulation of tissue fluid homeostasis, immune surveillance, and the transport of nutrients, and conversely this system is affected by, and directly contributes to, disease processes within the intestine. Recent discoveries of specific lymphatic markers, factors promoting lymphangiogenesis, and factors selectively affecting the development of intestinal lymphatics hold promise for unlocking the role of lymphatics in the pathogenesis of diseases affecting the intestine and for intestinal lymphatic selective therapies. Vital to progress in understanding how the intestinal lymphatic system functions is integrating of recent advances identifying molecular pathways for lymphatic growth and remodeling with advanced imaging modalities to observe lymphatic function and dysfunction in vivo. PMID:20961303

  19. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    PubMed

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  20. Prospective Validation of Optimal Drain Management "The 3 × 3 Rule" after Liver Resection.

    PubMed

    Mitsuka, Yusuke; Yamazaki, Shintaro; Yoshida, Nao; Masamichi, Moriguchi; Higaki, Tokio; Takayama, Tadatoshi

    2016-09-01

    We previously established an optimal postoperative drain management rule after liver resection (i.e., drain removal on postoperative day 3 if the drain fluid bilirubin concentration is <3 mg/dl) from the results of 514 drains of 316 consecutive patients. This test set predicts that 274 of 316 patients (87.0 %) will be safely managed without adverse events when drain management is performed without deviation from the rule. To validate the feasibility of our rule in recent time period. The data from 493 drains of 274 consecutive patients were prospectively collected. Drain fluid volumes, bilirubin levels, and bacteriological cultures were measured on postoperative days (POD) 1, 3, 5, and 7. The drains were removed according to the management rule. The achievement rate of the rule, postoperative adverse events, hospital stay, medical costs, and predictive value for reoperation according to the rule were validated. The rule was achieved in 255 of 274 (93.1 %) patients. The drain removal time was significantly shorter [3 days (1-30) vs. 7 (2-105), p < 0.01], drain fluid infection was less frequent [4 patients (1.5 %) vs. 58 (18.4 %), p < 0.01], postoperative hospital stay was shorter [11 days (6-73) vs. 16 (9-59), p = 0.04], and medical costs were decreased [1453 USD (968-6859) vs. 1847 (4667-9498), p < 0.01] in the validation set compared with the test set. Five patients who required reoperation were predicted by the drain-based information and treated within 2 days after operation. Our 3 × 3 rule is clinically feasible and allows for the early removal of the drain tube with minimum infection risk after liver resection.

Top