Sample records for drains

  1. Randomized Controlled Trial to Reduce Bacterial Colonization of Surgical Drains After Breast and Axillary Operations

    PubMed Central

    Degnim, Amy C.; Scow, Jeffrey S.; Hoskin, Tanya L.; Miller, Joyce P.; Loprinzi, Margie; Boughey, Judy C.; Jakub, James W.; Throckmorton, Alyssa; Patel, Robin; Baddour, Larry M.

    2014-01-01

    Objective To determine if bacterial colonization of drains can be reduced by local antiseptic interventions. Summary Background Drains are a potential source of bacterial entry into surgical wounds and may contribute to surgical site infection (SSI) after breast surgery. Methods Following IRB approval, patients undergoing total mastectomy and/or axillary lymph node dissection were randomized to standard drain care (control) or drain antisepsis (treated). Standard drain care comprised twice daily cleansing with alcohol swabs. Antisepsis drain care included 1) a chlorhexidine disc at the drain exit site and 2) irrigation of the drain bulb twice daily with dilute sodium hypochlorite (Dakin’s) solution. Cultures results of drain fluid and tubing were compared between control and antisepsis groups. Results Overall, 100 patients with 125 drains completed the study with 48 patients (58 drains) in the control group and 52 patients (67 drains) in the antisepsis group. Cultures of drain bulb fluid at one week were positive (1+ or greater growth) in 66% (38/58) of control drains compared to 21% of antisepsis drains (14/67), (p=0.0001). Drain tubing cultures demonstrated >50 CFU in 19% (8/43) of control drains versus 0% (0/53) of treated drains (p=0.004). SSI was diagnosed in 6 patients (6%) - 5 patients in the control group and 1 patient in the antisepsis group (p=0.06). Conclusions Simple and inexpensive local antiseptic interventions with a chlorhexidine disc and hypochlorite solution reduce bacterial colonization of drains. Based on these data, further study of drain antisepsis and its potential impact on SSI rate is warranted. PMID:23518704

  2. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 23.1021 Section 23.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  3. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 23.1021 Section 23.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  4. A prospective randomized study of use of drain versus no drain after burr-hole evacuation of chronic subdural hematoma.

    PubMed

    Singh, Amit Kumar; Suryanarayanan, Bhaskar; Choudhary, Ajay; Prasad, Akhila; Singh, Sachin; Gupta, Laxmi Narayan

    2014-01-01

    Chronic subdural hematoma (CSDH) recurs after surgical evacuation in 5-30% of patients. Inserting subdural drain might reduce the recurrence rate, but is not commonly practiced. There are few prospective studies to evaluate the effect of subdural drains. A prospective randomized study to investigate the effect of subdural drains in the on recurrence rates and clinical outcome following burr-hole drainage (BHD) of CSDH was undertaken. During the study period, 246 patients with CSDH were assessed for eligibility. Among 200 patients fulfilling the eligibility criteria, 100 each were assigned to "drain group" (drain inserted into the subdural space following BHD) and "without drain group" (subdural drain was not inserted following BHD) using random allocation software. The primary end point was recurrence needing re-drainage up to a period of 6 months from surgery. Recurrence occurred in 9 of 100 patients with a drain, and 26 of 100 patients in without drain group (P = 0.002). The mortality was 5% in patients with drain and 4% in patients without drain group (P = 0.744). The medical and surgical complications were comparable between the two study groups. Use of a subdural drain after burr-hole evacuation of a CSDH reduces the recurrence rate and is not associated with increased complications.

  5. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 23.1021 Section 23.1021... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Oil System § 23.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  6. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 29.1021 Section 29.1021... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  7. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 27.1021 Section 27.1021... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Oil System § 27.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  8. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 25.1021 Section 25.1021... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  9. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 25.1021 Section 25.1021... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  10. 14 CFR 23.1021 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Oil system drains. 23.1021 Section 23.1021... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Oil System § 23.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain...

  11. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 29.1021 Section 29.1021... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  12. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Oil system drains. 27.1021 Section 27.1021... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Oil System § 27.1021 Oil system drains. A drain (or drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  13. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    PubMed Central

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  14. A Brief History of Two Common Surgical Drains.

    PubMed

    Meyerson, Joseph M

    2016-01-01

    The use of surgical drains is commonplace in all types of surgical procedures, and rarely do we take the time to contemplate or investigate the origins of these critical devices. Every surgeon should be familiar with the Jackson-Pratt drain and Blake drain, 2 of the most frequently used closed suction, negative-pressure drainage devices in surgery. These drains are used throughout the body in a wide variety of surgical procedures. The development and differences between these 2 devices are seldom known by the practicing surgeon. In this article, we delve into the ancient history of drains, the creation and alterations of the closed suction, negative-pressure drain that paved the way for the Jackson-Pratt and Blake drain. Finally, we will discuss the variety of reservoirs that attach to these drains and the origin of the well-known adage of when to pull a drain.

  15. A study of the complications of small bore 'Seldinger' intercostal chest drains.

    PubMed

    Davies, Helen E; Merchant, Shairoz; McGown, Anne

    2008-06-01

    Use of small bore chest drains (<14F), inserted via the Seldinger technique, has increased globally over the last few years. They are now used as first line interventions in most acute medical situations when thoracostomy is required. Limited data are available on the associated complications. In this study, the frequency of complications associated with 12F chest drains, inserted using the Seldinger technique, was quantified. A retrospective case note audit was performed of consecutive patients requiring pleural drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.

  16. Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces.

    PubMed

    Benton, Ian J; Benfield, Grant F A

    2009-10-01

    To compare treatment success of large- and small-bore chest drains in the treatment of spontaneous pneumothoraces the case-notes were reviewed of those admitted to our hospital with a total of 73 pneumothoraces and who were treated by trainee doctors of varying experience. Both a large- and a small-bore intercostal tube drain system were in use during the two-year period reviewed. Similar pneumothorax profile and numbers treated with both drains were recorded, resulting in a similar drain time and numbers of successful and failed re-expansion of pneumothoraces. Successful pneumothorax resolution was the same for both drain types and the negligible tube drain complications observed with the small-bore drain reflected previously reported experiences. However the large-bore drain was associated with a high complication rate (32%) with more infectious complications (24%). The small-bore drain was prone to displacement (21%). There was generally no evidence of an increased failure and morbidity, reflecting poorer expertise, in the non-specialist trainees managing the pneumothoraces. A practical finding however was that in those large pneumothoraces where re-expansion failed, the tip of the drain had not been sited at the apex of the pleural cavity irrespective of the drain type inserted.

  17. Chest Drain Fall-Out Rate According to Suturing Practices: A Retrospective Direct Comparison.

    PubMed

    Asciak, Rachelle; Addala, Dinesh; Karimjee, Juzer; Rana, Maaz Suhail; Tsikrika, Stamatoula; Hassan, Maged Fayed; Mercer, Rachel Mary; Hallifax, Robert John; Wrightson, John Matthew; Psallidas, Ioannis; Benamore, Rachel; Rahman, Najib Mahboob

    2018-06-14

    Chest drains often become displaced and require replacement, adding unnecessary risks to patients. Simple measures such as suturing of the drain may reduce fall-out rates; however, there is no direct data to demonstrate this and no standardized recommended practice that is evidence based. The study aimed to analyze the rate of chest drain fall out according to suturing practice. Retrospective analysis of all chest drain insertions (radiology and pleural teams) in 2015-2016. Details of chest drain fall out were collected from patient electronic records. Drain "fall out" was pre-hoc defined as the drain tip becoming dislodged outside the pleural cavity unintentionally before a clinical decision was taken to remove the drain. A total of 369 chest drains were inserted: sutured (n = 106, 28.7%; 44 male [41.5%], median age 74 [interquartile range (IQR) 21] years), and unsutured (n = 263, 71.3%; 139 male [52.9%], median age 68 [IQR 21] years). Of the sutured drains, 7 (6.6%) fell out after a mean of 3.3 days (SD 2.6) compared to 39 (14.8%; p = 0.04) unsutured drains falling out after a mean of 2.7 days (SD 2.0; p = 0.8). Within the limits of this retrospective analysis, these results -suggest that suturing of drains is associated with lower fall-out rates. © 2018 S. Karger AG, Basel.

  18. Might digital drains speed up the time to thoracic drain removal?

    PubMed

    Afoke, Jonathan; Tan, Carol; Hunt, Ian; Zakkar, Mustafa

    2014-07-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was: might digital drains speed up the time to thoracic drain removal in terms of time till chest drain removal, hospital stay and overall cost? A total of 296 papers were identified as a result of the search as described below. Of these, five papers provided the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of the papers are tabulated. A literature search revealed that several single-centre prospective randomized studies have shown significantly earlier removal of chest drains with digital drains ranging between 0.8 and 2.1 days sooner. However, there was heterogeneity in studies in the management protocol of chest drains in terms of the use of suction, number of drains and assessment for drain removal. Some protocols such as routinely keeping drains irrespective of the presence of air leak or drain output may have skewed results. Differences in exclusion criteria and protocols for discharging home with portable devices may have biased results. Due to heterogeneity in the management protocol of chest drains, there is conflicting evidence regarding hospital stay. The limited data on cost suggest that there may be significantly lower postoperative costs in the digital drain group. All the studies were single-centre series generally including patients with good preoperative lung function tests. Further larger studies with more robust chest drain management protocols are required especially to assess length of hospital stay, cost and whether the results are applicable to a larger patient population. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    NASA Astrophysics Data System (ADS)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  20. Drain Insertion in Chronic Subdural Hematoma: An International Survey of Practice.

    PubMed

    Soleman, Jehuda; Kamenova, Maria; Lutz, Katharina; Guzman, Raphael; Fandino, Javier; Mariani, Luigi

    2017-08-01

    To investigate whether, after the publication of grade I evidence that it reduces recurrence rates, the practice of drain insertion after burr-hole drainage of chronic subdural hematoma has changed. Further, we aimed to document various practice modalities concerning the insertion of a drain adopted by neurosurgeons internationally. We administered a survey to neurosurgeons worldwide with questions relating to the surgical treatment of chronic subdural hematoma, with an emphasis on their practices concerning the use of a drain. The preferred surgical technique was burr-hole drainage (89%). Most surgeons prefer to place a drain (80%), whereas in 56% of the cases the reason for not placing a drain was brain expansion after evacuation. Subdural drains are placed by 50% and subperiosteal drains by 27% of the responders, whereas 23% place primarily a subdural drain if possible and otherwise a subperiosteal drain. Three quarters of the responders leave the drain for 48 hours and give prophylactic antibiotic treatment, mostly a single-shot dose intraoperatively (70%). Routine postoperative computed tomography is done by 59% mostly within 24-48 hours after surgery (94%). Adjunct treatment to surgery rarely is used (4%). The publication of grade I evidence in favor of drain use influenced positively this practice worldwide. Some surgeons are still reluctant to insert a drain, especially when the subdural space is narrow after drainage of the hematoma. The insertion of a subperiosteal drain could be a good alternative solution. However, its outcome and efficacy must be evaluated in larger studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage

    PubMed Central

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Objective Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. Description We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. Methods After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at −20 cm H2O for 30 min. Results When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. Conclusion The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications. PMID:25478289

  2. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage.

    PubMed

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at -20 cm H2O for 30 min. When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, P<0.001). By 30 min, the split drain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications.

  3. 3. DRAINING & DRYING BUILDING, REINFORCED CONCRETE MUSHROOM COLUMNS WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. DRAINING & DRYING BUILDING, REINFORCED CONCRETE MUSHROOM COLUMNS WITH DROP PANELS SUPPORTING DRAINING BINS (IRON VALVES OF DRAINING BINS ARE EMBEDDED IN THE CEILING), VIEW LOOKING WEST - Mill "C" Complex, Sand Draining & Drying Building, South of Dee Bennet Road, near Illinois River, Ottawa, La Salle County, IL

  4. Evisceration of Appendix through the Drain Site: A Rare Case Report.

    PubMed

    Ravishankaran, Praveen; Rajamani, A

    2013-06-01

    Placing a drain after surgery is a usual procedure in any emergency abdominal operation. The drain is removed as soon as its purpose of draining the intraabdominal collection in served. Evisceration of intraabdominal organs through the drain site is a rare occurance. This case report is about an 12 year old girl who was admitted with blunt trauma abdomen. After completion of emergency laparotomy a drain was placed in the right lower quadrant. When the drain was removed on the 6th post operative day, the appendix eviscerated out of the drain site. The wound was extended a little and an appendectomy was done. This case is presented for its rarity as only two similar instances have been reported in literature so far.

  5. A forgotten retained drain inside a knee for 10 years: A case report.

    PubMed

    Koaban, Saeed; Alatassi, Raheef; Alogayyel, Nawaf

    2018-05-29

    Surgical drains are inserted into the wound after an arthroscopic knee procedure mainly to decrease fluid collection after the operation. The use of postoperative surgical drains remains controversial. This report presents a rare case of a forgotten retained drain that was accidentally found inside a knee 10 years after an arthroscopic procedure. The drain was removed without any complications. A retained and broken drain during removal is a very rare and preventable complication that can be stressful for both the patient and surgeon. Most of the literature supports that retained drains in the soft tissues do not affect long-term outcomes, but if the drain fragment is in the intra-articular area, it might cause complications. Furthermore, there are several preventive measures to avoid retained surgical drains. By reporting this case of a forgotten drain retained inside a knee for approximately 10 years, we aim to illustrate the potential risk of leaving a drain inside the joint following an arthroscopic procedure. Furthermore, we advise that surgeons maintain a high index of suspicion for iatrogenic complications when a patient continues to complain about unexplained pain at the surgical site. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Estimating drain flow from measured water table depth in layered soils under free and controlled drainage

    NASA Astrophysics Data System (ADS)

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-01-01

    Long records of continuous drain flow are important for quantifying annual and seasonal changes in the subsurface drainage flow from drained agricultural land. Missing data due to equipment malfunction and other challenges have limited conclusions that can be made about annual flow and thus nutrient loads from field studies, including assessments of the effect of controlled drainage. Water table depth data may be available during gaps in flow data, providing a basis for filling missing drain flow data; therefore, the overall goal of this study was to examine the potential to estimate drain flow using water table observations. The objectives were to evaluate how the shape of the relationship between drain flow and water table height above drain varies depending on the soil hydraulic conductivity profile, to quantify how well the Hooghoudt equation represented the water table-drain flow relationship in five years of measured data at the Davis Purdue Agricultural Center (DPAC), and to determine the impact of controlled drainage on drain flow using the filled dataset. The shape of the drain flow-water table height relationship was found to depend on the selected hydraulic conductivity profile. Estimated drain flow using the Hooghoudt equation with measured water table height for both free draining and controlled periods compared well to observed flow with Nash-Sutcliffe Efficiency values above 0.7 and 0.8 for calibration and validation periods, respectively. Using this method, together with linear regression for the remaining gaps, a long-term drain flow record for a controlled drainage experiment at the DPAC was used to evaluate the impacts of controlled drainage on drain flow. In the controlled drainage sites, annual flow was 14-49% lower than free drainage.

  7. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  8. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  9. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  10. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  11. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  12. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  13. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  14. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  15. 14 CFR 29.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 29.999 Section 29.999... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  16. 14 CFR 27.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 27.999 Section 27.999... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.999 Fuel system drains. (a) There must be at least one accessible drain at the lowest point in each fuel system to completely drain...

  17. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  18. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  19. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  20. 21 CFR 868.5995 - Tee drain (water trap).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  1. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    PubMed

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  2. Bacterial diversity of floor drain biofilms and drain waters in a Listeria monocytogenes contaminated food processing environment.

    PubMed

    Dzieciol, Monika; Schornsteiner, Elisa; Muhterem-Uyar, Meryem; Stessl, Beatrix; Wagner, Martin; Schmitz-Esser, Stephan

    2016-04-16

    Sanitation protocols are applied on a daily basis in food processing facilities to prevent the risk of cross-contamination with spoilage organisms. Floor drain water serves along with product-associated samples (slicer dust, brine or cheese smear) as an important hygiene indicator in monitoring Listeria monocytogenes in food processing facilities. Microbial communities of floor drains are representative for each processing area and are influenced to a large degree by food residues, liquid effluents and washing water. The microbial communities of drain water are steadily changing, whereas drain biofilms provide more stable niches. Bacterial communities of four floor drains were characterized using 16S rRNA gene pyrosequencing to better understand the composition and exchange of drain water and drain biofilm communities. Furthermore, the L. monocytogenes contamination status of each floor drain was determined by applying cultivation-independent real-time PCR quantification and cultivation-dependent detection according to ISO11290-1. Pyrosequencing of 16S rRNA genes of drain water and drain biofilm bacterial communities yielded 50,611 reads, which were clustered into 641 operational taxonomic units (OTUs), affiliated to 16 phyla dominated by Proteobacteria, Firmicutes and Bacteroidetes. The most abundant OTUs represented either product- (Lactococcus lactis) or fermentation- and food spoilage-associated phylotypes (Pseudomonas mucidolens, Pseudomonas fragi, Leuconostoc citreum, and Acetobacter tropicalis). The microbial communities in DW and DB samples were distinct in each sample type and throughout the whole processing plant, indicating the presence of indigenous specific microbial communities in each processing compartment. The microbiota of drain biofilms was largely different from the microbiota of the drain water. A sampling approach based on drain water alone may thus only provide reliable information on planktonic bacterial cells but might not allow conclusions on the bacterial composition of the microbiota in biofilms. Copyright © 2016. Published by Elsevier B.V.

  3. [Outpatient Drain Management in Patients with Clinically Relevant Postoperative Pancreatic Fistula (CR-POPF) - Current Status in Germany].

    PubMed

    Hempel, Sebastian; Püttmann, Pamela; Kahlert, Christoph; Seifert, Lena; Mees, Sören Torge; Welsch, Thilo; Weitz, Jürgen; Distler, Marius

    2018-06-01

    Postoperative pancreatic fistula (POPF) is a common complication after pancreatic surgery and is associated with extended hospitalisation, increased medical costs, and reduced quality of life. The aim of the present study was to assess the treatment of POPF in Germany, with a special focus on outpatient drain management in patients with clinically relevant POPF (CR-POPF). A questionnaire evaluating postoperative management once a CR-POPF is diagnosed - especially focusing on ambulatory drain management - was developed and sent to 211 German hospitals performing > 12 pancreatic operations per year. Statistical analysis was carried out using SPSS 21. The final response rate was 62% (n = 131). Outpatient drainage management is performed by most of the responding hospitals (n = 100, 76.3%). However, 30% of hospitals (n = 40) perform outpatient treatment only in 5% of their cases with clinically relevant POPF. There was no correlation between case load of the pancreatic centres and frequency of outpatient drain management. In general, discharge criteria for patients with drained POPF (n = 98, 74.8%), the drain management itself (n = 95, 72.5%) and criteria for drain removal (n = 74, 56.5%) are not standardised but made individually. In centres with standardised drain management criteria for drain removal, these criteria were drain volume < 20 ml (29.8%), no fluid collection (25.2%), no elevation of drain amylase/lipase (25.2%) and no specific symptoms (22.1%). This is the first survey in Germany evaluating outpatient drain management in patients with CR-POPF. Although the data in the literature are rare, the majority of German pancreatic surgeons perform outpatient drain management. However, discharge criteria, outpatient care and drain removal are standardised in only the minority of centres. Therefore, we recommend the evaluation of discharge criteria and a management algorithm for patients with drained CR-POPF to improve the perioperative course. Georg Thieme Verlag KG Stuttgart · New York.

  4. Drivers of variability in tree transpiration in a Boreal Black Spruce Forest Chronosequence

    NASA Astrophysics Data System (ADS)

    Angstmann, J. L.; Ewers, B. E.; Kwon, H.

    2009-12-01

    Boreal forests are of particular interest in climate change studies because of their large land area and ability to sequester and store carbon, which is controlled by water availability. Heterogeneity of these forests is predicted to increase with climate change through the impact of more frequent wildfires, warmer, longer growing seasons, and potential drainage of forested wetlands. This study aims to quantify the influence of stand age, drainage condition, and species on tree transpiration and its drivers in a central Canadian black spruce boreal forest. Heat dissipation sensors were installed in 113 trees (69 Picea mariana (black spruce), 25 Populus tremuloides (trembling aspen), and 19 Pinus banksiana (jack pine) at four stand ages, each containing a well- and poorly-drained site over three growing seasons (2006-2008). Sap flux per unit xylem area, JS, was expressed as transpiration per unit ground area, EC, and transpiration per unit leaf area, EL, using site- and species-specific allometry to obtain sapwood area (AS)and leaf area(AL)per unit ground area. Well-drained, younger Picea mariana daily JS was 47-64% greater than the older well-drained burn ages and younger poorly-drained stands were 64-68% greater than the two oldest poorly-drained stands. Daily EL in the well-drained Picea mariana stands was on average 12-33% higher in younger stand than in the two oldest stands whereas young, poorly-drained Picea mariana had 71% greater daily EL than the older stands. Well-drained Picea mariana trees had 52% higher daily EC than older trees and poorly-drained Picea mariana in the 1964 burn had 42-81% higher daily EC than the oldest stands. Populus tremuloides located in the two youngest stands had daily JS 38-58% greater rates than the 1930 burn, whereas daily EL and EC had no distint differences due to high interannual variability. Pinus banksiana experienced 21-33% greater daily JS in the 1989 burn than in the older 1964 burn for well- and poorly-drained sites. Poorly-drained Pinus banksiana trees from the older 1964 burn had 23-48% greater daily EL and 26-39% higher daily EC than the 1989 burn. Poorly-drained Picea mariana had 17-31% higher daily JS than the well-drained sites. Poorly-drained Picea mariana had 29-58% higher daily EL 42-50% higher daily EC than the well-drained trees. Poorly-drained Pinus banksiana on average had 27-28% higher daily JS than well-drained trees. Poorly-drained Pinus banskiana had 23.25% higher daily EL than well-drained trees and daily EC 32-67% lower than the well-drained trees. Drivers of these differences include midday leaf water potential, AS, and AL.

  5. Controlling the ambipolarity and improvement of RF performance using Gaussian Drain Doped TFET

    NASA Astrophysics Data System (ADS)

    Nigam, Kaushal; Gupta, Sarthak; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2018-05-01

    Ambipolar conduction in tunnel field-effect transistors (TFETs) has been occurred as an inherent issue due to drain-channel tunneling. It makes TFET less efficient and restricts its application in complementary digital circuits. Therefore, this manuscript reports the application of Gaussian doping profile on nanometer regime silicon channel TFETs to completely eliminate the ambipolarity. For this, Gaussian doping is used in the drain region of conventional gate-drain overlap TFET to control the tunneling of electrons from the valence band of channel to the conduction band of drain. As a result, barrier width at the drain/channel junction increases significantly leading to the suppression of an ambipolar current even when higher doping concentration (1 ? 10 ? cm ?) is considered in the drain region. However, significant improvement in terms of RF figure-of-merits such as cut-off frequency (f ?), gain bandwidth product (GBW), and gate-to-drain capacitance (C ?) is achieved with Gaussian doped gate on drain overlap TFET as compared to its counterpart TFET.

  6. Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion

    PubMed Central

    Rotman, Jessica A.; Getrajdman, George I.; Maybody, Majid; Erinjeri, Joseph P.; Yarmohammadi, Hooman; Sofocleous, Constantinos T.; Solomon, Stephen B.; Boas, F. Edward

    2016-01-01

    Background The purpose of this study is to determine whether larger abdominopelvic abscess drains reduce the time required for abscess resolution, or the probability of tube occlusion. Methods 144 consecutive patients who underwent abscess drainage at a single institution were reviewed retrospectively. Results: Larger initial drain size did not reduce drainage time, drain occlusion, or drain exchanges (p>0.05). Subgroup analysis did not find any type of collection that benefitted from larger drains. A multivariate model predicting drainage time showed that large collections (>200 ml) required 16 days longer drainage time than small collections (<50 ml). Collections with a fistula to bowel required 17 days longer drainage time than collections without a fistula. Initial drain size and the viscosity of the fluid in the collection had no significant effect on drainage time in the multivariate model. Conclusions 8 F drains are adequate for initial drainage of most serous and serosanguineous collections. 10 F drains are adequate for initial drainage of most purulent or bloody collections. PMID:27634422

  7. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    PubMed Central

    2010-01-01

    Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery. PMID:20492665

  8. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    PubMed

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  9. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    PubMed

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  10. An elevated source/drain-on-insulator structure to maximize the intrinsic performance of extremely scaled MOSFETs

    NASA Astrophysics Data System (ADS)

    Zhang, Zhikuan; Zhang, Shengdong; Feng, Chuguang; Chan, Mansun

    2003-10-01

    In this paper, a source/drain structure separated from the silicon substrate by oxide isolation is fabricated and studied. The source/drain diffusion regions are connected to the shallow source/drain extension through a smaller opening defined by a double spacer process. Experimental results indicate that the source/drain on insulator significantly reduces the parasitic capacitance. Further optimization by simulation indicates a reduction of series resistance and band-to-band drain leakage at off-state can be achieved in extremely scaled devices. Compared with the conventional planner source/drain structure, the reduction of parasitic capacitance and series resistance can be as much as 80% and 30% respectively.

  11. Prospective Validation of Optimal Drain Management "The 3 × 3 Rule" after Liver Resection.

    PubMed

    Mitsuka, Yusuke; Yamazaki, Shintaro; Yoshida, Nao; Masamichi, Moriguchi; Higaki, Tokio; Takayama, Tadatoshi

    2016-09-01

    We previously established an optimal postoperative drain management rule after liver resection (i.e., drain removal on postoperative day 3 if the drain fluid bilirubin concentration is <3 mg/dl) from the results of 514 drains of 316 consecutive patients. This test set predicts that 274 of 316 patients (87.0 %) will be safely managed without adverse events when drain management is performed without deviation from the rule. To validate the feasibility of our rule in recent time period. The data from 493 drains of 274 consecutive patients were prospectively collected. Drain fluid volumes, bilirubin levels, and bacteriological cultures were measured on postoperative days (POD) 1, 3, 5, and 7. The drains were removed according to the management rule. The achievement rate of the rule, postoperative adverse events, hospital stay, medical costs, and predictive value for reoperation according to the rule were validated. The rule was achieved in 255 of 274 (93.1 %) patients. The drain removal time was significantly shorter [3 days (1-30) vs. 7 (2-105), p < 0.01], drain fluid infection was less frequent [4 patients (1.5 %) vs. 58 (18.4 %), p < 0.01], postoperative hospital stay was shorter [11 days (6-73) vs. 16 (9-59), p = 0.04], and medical costs were decreased [1453 USD (968-6859) vs. 1847 (4667-9498), p < 0.01] in the validation set compared with the test set. Five patients who required reoperation were predicted by the drain-based information and treated within 2 days after operation. Our 3 × 3 rule is clinically feasible and allows for the early removal of the drain tube with minimum infection risk after liver resection.

  12. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    USGS Publications Warehouse

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the curtain-drain samples from the ETA systems showed somewhat more evidence of the presence of HSTS water than did the LL systems, most of the approaches were inconclusive by themselves. The best evidence of HSTS water, from the Cl/Br ratios, indicates that the water in 10 of the 11 curtain drains, at both HSTS types, was a mixture of dilute ground water and HSTS-derived water; the 11th drain also show some effects of the HSTS, although road salt-affected water may be present. Therefore, it appears that there is no difference between the ETA and LL systems with respect to the water quality in curtain drains.

  13. Safety drain system for fluid reservoir

    NASA Technical Reports Server (NTRS)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2012-01-01

    A safety drain system includes a plurality of drain sections, each of which defines distinct fluid flow paths. At least a portion of the fluid flow paths commence at a side of the drain section that is in fluid communication with a reservoir's fluid. Each fluid flow path at the side communicating with the reservoir's fluid defines an opening having a smallest dimension not to exceed approximately one centimeter. The drain sections are distributed over at least one surface of the reservoir. A manifold is coupled to the drain sections.

  14. Containment vessel drain system

    DOEpatents

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  15. Evaluation of wick drain performance in Virginia soils.

    DOT National Transportation Integrated Search

    2003-01-01

    Prefabricated vertical drains (PVD), also known as wick drains, are commonly used to accelerate the consolidation of fine-grained soils in order to reduce future settlements and increase shear strength. Various drain designs are currently on the mark...

  16. Effect of abdominopelvic abscess drain size on drainage time and probability of occlusion.

    PubMed

    Rotman, Jessica A; Getrajdman, George I; Maybody, Majid; Erinjeri, Joseph P; Yarmohammadi, Hooman; Sofocleous, Constantinos T; Solomon, Stephen B; Boas, F Edward

    2017-04-01

    The purpose of this study is to determine whether larger abdominopelvic abscess drains reduce the time required for abscess resolution or the probability of tube occlusion. 144 consecutive patients who underwent abscess drainage at a single institution were reviewed retrospectively. Larger initial drain size did not reduce drainage time, drain occlusion, or drain exchanges (P > .05). Subgroup analysis did not find any type of collection that benefitted from larger drains. A multivariate model predicting drainage time showed that large collections (>200 mL) required 16 days longer drainage time than small collections (<50 mL). Collections with a fistula to bowel required 17 days longer drainage time than collections without a fistula. Initial drain size and the viscosity of the fluid in the collection had no significant effect on drainage time in the multivariate model. 8 F drains are adequate for initial drainage of most serous and serosanguineous collections. 10 F drains are adequate for initial drainage of most purulent or bloody collections. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Preferential flow estimates to an agricultural tile drain with implications for glyphosate transport

    USGS Publications Warehouse

    Stone, W.W.; Wilson, J.T.

    2006-01-01

    Agricultural subsurface drains, commonly referred to as tile drains, are potentially significant pathways for the movement of fertilizers and pesticides to streams and ditches in much of the Midwest. Preferential flow in the unsaturated zone provides a route for water and solutes to bypass the soil matrix and reach tile drains faster than predicted by traditional displacement theory. This paper uses chloride concentrations to estimate preferential flow contributions to a tile drain during two storms in May 2004. Chloride, a conservative anion, was selected as the tracer because of differences in chloride concentrations between the two sources of water to the tile drain, preferential and matrix flow. A strong correlation between specific conductance and chloride concentration provided a mechanism to estimate chloride concentrations in the tile drain throughout the storm hydrographs. A simple mixing analysis was used to identify the preferential flow component of the storm hydrograph. During two storms, preferential flow contributed 11 and 51% of total storm tile drain flow; the peak contributions, 40 and 81%, coincided with the peak tile drain flow. Positive relations between glyphosate [N-(phosphonomethyl)glycine] concentrations and preferential flow for the two storms suggest that preferential flow is an important transport pathway to the tile drain. ?? ASA, CSSA, SSSA.

  18. Phytoplankton abundance and structure as indicator of water quality in the drainage system of the Burullus Lagoon, southern Mediterranean coast, Egypt.

    PubMed

    El-Kassas, Hala Yassin; Gharib, Samiha Mahmoud

    2016-09-01

    This study represents the first detailed account of phytoplankton community structure and seasonal succession in eight drain sites and the Brimbal Canal influx into the Burullus Lagoon. The phytoplankton characteristics were studied based on the data collected seasonally over 4 years, from summer 2012 to spring 2016. Various indices such as Palmer's and Shannon's biotic indices were used for the assessment of the water quality of the different drains. There were a total of 194 species belonging to 65 genera and 6 groups: Bacillariophyceae (76 species), Chlorophyceae (59 species), Cyanophyceae (30 species), Euglenophyceae (25 species), Dinophyceae (3 species), and Xanthophyceae (1 species). The phytoplankton community was dominated with diatoms, green algae, and euglenoids such as Cyclotella, Scenedesmus, Navicula, Nitzschia, Ankistrodesmus, Chlorella, and Euglena. Maximum and minimum phytoplankton abundance was recorded at the Brimbal Canal and Hooks Drain. Maximum and minimum species diversities (H') were found at the Hooks Drain (2.564) and Burullus Drain (2.055). Species evenness fluctuated between 0.595 (Burullus Drain) and 0.750 (West Burullus Drain). The total score of algal genus pollution index and the algal species pollution index at the different drains showed that Drain 7 and the West Burullus Drain had moderate pollution, and the total score of the other drains were greater than 20 indicating the confirmed high organic pollution. Thus, the present investigation can be considered an attempt to use the phytoplankton community as a bioindicator of organic pollution.

  19. Discharge characteristics of four highway drainage systems in Ohio

    USGS Publications Warehouse

    Straub, D.E.

    1995-01-01

    Excessive water in the subbase of high-way combined with large traffic volumes and heavy loads is a major cause of road deterioration. Prompt removal of any excess water in a subbase will decrease the road deterioration and extend the effective life of a highway. This study presents discharge characteristics of four highway subbase drainage systems. These systems consisted of shallow, longitudal trenches with geocomposite drain materials (edge drains made from a polyethylene core surrounded by a geotextile filter fabric) that underline the joint between the shoulder and the traffic lane of State Route 16, approximately 1.0 mile southeast of Granville, Ohio. For selected rainfall-runoff events the maximum discharge, discharge characteristics from April 1991 through November 1993 were computed for three geocomposite products- a post type, an oblong-pipe type, and a cusp type-and a conventional perforated pipe edge drain. In general, the discharge characteristics of the conventional edge drain and that of the oblong-pipe edge drain were similar for most of the rainfall-runoff event characteristics. Both produced most of the highest maximum discharges and largest discharge volumes among the four longitudal edge drains. The post edge drain produced smaller maximum discharge and volumes than the conventional and oblong-pipe edge drains, but it had the shortest lag times for most of the event characteristics. The cusp edge drain produced small maximum discharges and small volumes similar to those from the post edge drain, but it had the longest lag times of all the edge drains for most of the event characteristics. The cusp edge drain may have also had some problems during installation which could have affected the discharge characteristics.

  20. Fallopian Tube Herniation through Left Sided Abdominal Drain Site.

    PubMed

    Hussain, Khalid; Masood, Jovaria

    2016-06-01

    Intra-abdominal drains have been used since long to prevent intra-abdominal collection, and detect any anastomotic leaks. We report a case of left sided fallopian tube herniation from a left lower abdominal drain site in a 27-year female who underwent caesarian section for breach presentation. Several complications related to drain usage has been described but left sided fallopian tube prolapse through drain site has not been reported in literature.

  1. Drain Management after Pancreatoduodenectomy: Reappraisal of a Prospective Randomized Trial Using Risk Stratification.

    PubMed

    McMillan, Matthew T; Malleo, Giuseppe; Bassi, Claudio; Butturini, Giovanni; Salvia, Roberto; Roses, Robert E; Lee, Major K; Fraker, Douglas L; Drebin, Jeffrey A; Vollmer, Charles M

    2015-10-01

    A recent randomized trial used the Fistula Risk Score (FRS) to develop guidelines for selective drainage based on clinically relevant fistula (CR-POPF) risk. Additionally, postoperative day (POD) 1 drain and serum amylase have been identified as accurate postoperative predictors of CR-POPF. This study sought to identify patients who may benefit from selective drainage, as well as the optimal timing for drain removal after pancreatoduodenectomy. One hundred six pancreatoduodenectomies from a previously reported RCT were assessed using risk-adjustment. The incidence of CR-POPF was compared between FRS risk cohorts. Drain and serum amylase values from POD 1 were evaluated using receiver operating characteristic (ROC) analysis to establish cut-offs predictive of CR-POPF occurrence. A regression analysis compared drain removal randomizations (POD 3 vs POD 5). Three-quarters of patients had moderate/high CR-POPF risk. This group had a CR-POPF rate of 36.3% vs 7.7% among negligible/low risk patients (p = 0.005). The areas under the ROC curve for CR-POPF prediction using POD 1 drain and serum amylase values were 0.800 (p = 0.000001; 95% CI 0.70-0.90) and 0.655 (p = 0.012; 95% CI 0.55-0.77), respectively. No significant serum amylase cut-offs were identified. Moderate/high risk patients with POD 1 drain amylase ≤ 5,000 U/L had significantly lower rates of CR-POPF when randomized to POD 3 drain removal (4.2% vs 38.5%; p = 0.003); moreover, these patients experienced fewer complications and shorter hospital stays. A clinical care protocol is proposed whereby drains are recommended for moderate/high FRS risk patients, but may be omitted in patients with negligible/low risk. Drain amylase values in moderate/high risk patients should then be evaluated on POD 1 to determine the optimal timing for drain removal. Moderate/high risk patients with POD 1 drain amylase ≤ 5,000 U/L have lower rates of CR-POPF with POD 3 (vs POD ≥ 5) drain removal; early drain removal is recommended for these patients. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Effect of polluted water on soil and plant contamination by heavy metals in El-Mahla El-Kobra, Egypt

    NASA Astrophysics Data System (ADS)

    Kasem Mahmoud, Esawy; Ghoneim, Adel Mohamed

    2016-04-01

    The discharge of untreated waste water in Zefta drain and drain no. 5 is becoming a problem for many farmers in the El-Mahla El-Kobra area, Egypt. The discharged water contains high levels of contaminants considered hazardous to the ecosystem. Some plants, soil, water, and sediment samples were collected from the El-Mahla El-Kobra area to evaluate the contamination by heavy metals. The results showed that the heavy metals, pH, sodium adsorption ratio (SAR), biochemical oxygen demand (BOD), and chemical oxygen demand (COD) in the water of Zefta drain and drain no. 5 exceeded permissible limits for irrigation. In rice and maize shoots grown in soils irrigated by contaminated water from Zefta drain and drain no. 5, the bioaccumulation factors for Cd, Pb, Zn, Cu, and Mn were higher than 1.0. The heavy metals content of irrigated soils from Zefta drain and drain no. 5 exceeded the upper limit of background heavy metals. In this study, the mean contaminant factor values of the drain no. 5 sediments revealed that Zn, Mn, Cu, Cd, Pb, and Ni > 6, indicating very high contamination. The bioaccumulation coefficient values of Cynodon dactylon, Phragmites australis, and Typha domingensis aquatic plants growing in Zefta drain are high. These species can be considered as hyperaccumulators for the decontamination of contaminated water.

  3. A novel thin-film transistor with step gate-overlapped lightly doped drain and raised source/drain design

    NASA Astrophysics Data System (ADS)

    Chien, Feng-Tso; Chen, Jian-Liang; Chen, Chien-Ming; Chen, Chii-Wen; Cheng, Ching-Hwa; Chiu, Hsien-Chin

    2017-11-01

    In this paper, a novel step gate-overlapped lightly doped drain (GOLDD) with raised source/drain (RSD) structure (SGORSD) is proposed for TFT electronic device application. The new SGORSD structure could obtain a low electric field at channel near the drain side owing to a step GOLDD design. Compared to the conventional device, the SGORSD TFT exhibits a better kink effect and higher breakdown performance due to the reduced drain electric field (D-EF). In addition, the leakage current also can be suppressed. Moreover, the device stability, such as the threshold voltage shift and drain current degradation under a high gate bias, is improved by the design of SGORSD structure. Therefore, this novel step GOLDD structure can be a promising design to be used in active-matrix flat panel electronics.

  4. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery.

    PubMed

    Connolly, J; Holden, N M

    2017-12-01

    Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA) was performed on a very high resolution satellite image (Geoeye-1) to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality (CCQ) were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA) of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95-97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO 2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of drains on a blanket bog in the west of Ireland. The results show that information on drain extent and location can be extracted from high resolution imagery and mapped with a high degree of accuracy. Under Article 3.4 of the Kyoto Protocol Annex 1 parties can account for greenhouse gas emission by sources and removals by sinks resulting from "wetlands drainage and rewetting". The ability to map the spatial extent, density and location of peatlands drains means that Annex 1 parties can develop strategies for drain blocking to aid reduction of CO 2 emissions, DOC runoff and water discoloration. This paper highlights some uncertainty around using one-size-fits-all emission factors for GHG in drained peatlands and re-wetting scenarios. However, the OBIA method is robust and accurate and could be used to assess the extent of drains in peatlands across the globe aiding the refinement of peatland carbon dynamics .

  5. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery.

    PubMed

    Connolly, J; Holden, N M

    2017-12-01

    Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA) was performed on a very high resolution satellite image (Geoeye-1) to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality ( CCQ ) were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA) of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95-97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO 2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of drains on a blanket bog in the west of Ireland. The results show that information on drain extent and location can be extracted from high resolution imagery and mapped with a high degree of accuracy. Under Article 3.4 of the Kyoto Protocol Annex 1 parties can account for greenhouse gas emission by sources and removals by sinks resulting from "wetlands drainage and rewetting". The ability to map the spatial extent, density and location of peatlands drains means that Annex 1 parties can develop strategies for drain blocking to aid reduction of CO 2 emissions, DOC runoff and water discoloration. This paper highlights some uncertainty around using one-size-fits-all emission factors for GHG in drained peatlands and re-wetting scenarios. However, the OBIA method is robust and accurate and could be used to assess the extent of drains in peatlands across the globe aiding the refinement of peatland carbon dynamics .

  6. Comparative effect of tube drain on post operative inflammatory complications of impacted mandibular third molar surgery College Hospital, Ibadan, Nigeria.

    PubMed

    Obimakinde, O S; Fasola, A O; Arotiba, J T; Okoje, V N; Obiechina, A E

    2010-09-01

    Swelling, pain and trismus are acute reversible inflammatory complications of impacted mandibular third molar (M3) surgery. They contribute to the deterioration of quality of life and loss of several useful working hours. This study aimed to investigate whether the use of a surgical drain following M3 surgery can minimise these inflammatory complications. Eighty consecutive patients who gave consent were enrolled into the study. Patients were assigned into two groups (drain and no drain) by systematic sampling method which was modified to ensure matching of patients by age, sex and spatial relationship of the impacted mandibular third molar. The patients in the drain group (n=40) had a Foley's catheter drain inserted into the wound after the surgical procedure while the patients in the no drain group (n=40) had their wound closed without the use of drain. All patients had primary wound closure with 3.0 black silk sutures after the procedure. Demographic data, cheek dimension and maximal mouth opening were recorded before the procedure. Pain, swelling and trismus were evaluated in the two groups at 24 hours, 48 hours and 7th day after surgery. Post operative swelling and visual analogue scale score for pain were comparatively lesser in the drain group patients. The maximal interincisal distance was also more in the drain group patients. The findings from this study indicated that there is a significant benefit of using a surgical drain in minimising postoperative oedema, pain and trismus following surgical removal of impacted mandibular third molar.

  7. 77 FR 70382 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... the fuel tank draining system. This proposed AD is prompted by a closed fuel tank drain that, in the... fuel tank compartments' draining system. FAA's Determination These helicopters have been approved by... buoyancy fixed parts, the ASBs describe procedures to modify the fuel tank draining system by removing...

  8. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 29.1021 Section 29.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  9. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 25.1021 Section 25.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  10. 14 CFR 29.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 29.1021 Section 29.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  11. 14 CFR 25.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 25.1021 Section 25.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... drains) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible...

  12. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  13. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  14. 14 CFR 125.139 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil system drains. 125.139 Section 125.139....139 Oil system drains. Accessible drains incorporating either a manual or automatic means for positive locking in the closed position must be provided to allow safe drainage of the entire oil system. ...

  15. 46 CFR 45.157 - Scuppers and gravity drains.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  16. 46 CFR 45.157 - Scuppers and gravity drains.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  17. 46 CFR 45.157 - Scuppers and gravity drains.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  18. 46 CFR 45.157 - Scuppers and gravity drains.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  19. 46 CFR 45.157 - Scuppers and gravity drains.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  20. Pontine infarction caused by medial branch injury of the basilar artery as a rare complication of cisternal drain placement.

    PubMed

    Horiuchi, Tetsuyoshi; Yamamoto, Yasunaga; Kuroiwa, Masafumi; Rahmah, Nunung Nur; Hongo, Kazuhiro

    2012-04-01

    We present a rare complication of cisternal drain placement during aneurysm surgery. A ruptured anterior communicating artery aneurysm was clipped through a right pterional approach. A cisternal drain was inserted from the retro-carotid to the prepontine cistern. Postoperatively, a left-sided paresis of the upper extremity had developed. A CT brain scan revealed that the drain was located between the pons and the basilar artery, resulting in a pontine infarction. Vascular neurosurgeons should keep this complication in mind when placing a cisternal drain tube. The drain tube should not be inserted too deep into the prepontine cistern. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Dong-Suk; Kang, Yu-Jin; Park, Jae-Hyung

    Highlights: • We developed and investigated source/drain electrodes in oxide TFTs. • The Mo S/D electrodes showed good output characteristics. • Intrinsic TFT parameters were calculated by the transmission line method. - Abstract: This paper investigates the feasibility of a low-resistivity electrode material (Mo) for source/drain (S/D) electrodes in thin film transistors (TFTs). The effective resistances between Mo source/drain electrodes and amorphous zinc–tin-oxide (a-ZTO) thin film transistors were studied. Intrinsic TFT parameters were calculated by the transmission line method (TLM) using a series of TFTs with different channel lengths measured at a low source/drain voltage. The TFTs fabricated with Momore » source/drain electrodes showed good transfer characteristics with a field-effect mobility of 10.23 cm{sup 2}/V s. In spite of slight current crowding effects, the Mo source/drain electrodes showed good output characteristics with a steep rise in the low drain-to-source voltage (V{sub DS}) region.« less

  2. Rupture disc

    DOEpatents

    Newton, Robert G.

    1977-01-01

    The intermediate heat transport system for a sodium-cooled fast breeder reactor includes a device for rapidly draining the sodium therefrom should a sodium-water reaction occur within the system. This device includes a rupturable member in a drain line in the system and means for cutting a large opening therein and for positively removing the sheared-out portion from the opening cut in the rupturable member. According to the preferred embodiment of the invention the rupturable member includes a solid head seated in the end of the drain line having a rim extending peripherally therearound, the rim being clamped against the end of the drain line by a clamp ring having an interior shearing edge, the bottom of the rupturable member being convex and extending into the drain line. Means are provided to draw the rupturable member away from the drain line against the shearing edge to clear the drain line for outflow of sodium therethrough.

  3. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  4. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  5. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  6. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  7. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  8. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  9. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  10. 14 CFR 25.999 - Fuel system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...

  11. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  12. 14 CFR 23.999 - Fuel system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 23.999 Section 23.999... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System Components § 23.999 Fuel system drains. (a) There must be at least one drain to allow safe drainage of the entire...

  13. Nutrient Drain Associated with Hardwood Plantation Culture

    Treesearch

    James B. Baker

    1978-01-01

    Past research and a tentative evaluation indicate that nutrient drain and possible site degradation could occur in southern hardwood plantations. The extent of nutrient drain on a given site would depend on the species, length of the rotation, and harvesting system used. The evaluation for cottonwood plantations in Mississippi indicates that nutrient drain is most...

  14. The management of vacuum neck drains in head and neck surgery and the comparison of two different practice protocols for drain removal.

    PubMed

    Kasbekar, A V; Davies, F; Upile, N; Ho, M W; Roland, N J

    2016-01-01

    Introduction The management of vacuum neck drains in head and neck surgery is varied. We aimed to improve early drain removal and therefore patient discharge in a safe and effective manner. Methods The postoperative management of head and neck surgical patients with vacuum neck drains was reviewed retrospectively. A new policy was then implemented to measure drainage three times daily (midnight, 6am, midday). The decision for drain removal was based on the most recent drainage period (at <3ml per hour). A further patient cohort was subsequently assessed prospectively. The length of hospital stay was compared between the cohorts. Results The retrospective audit included 51 patients while the prospective audit included 47. The latter saw 16 patients (33%) discharged at least one day earlier than they would have been under the previous policy. No adverse effects were noted from earlier drain removal. Conclusions Measuring drainage volumes three times daily allows for more accurate assessment of wound drainage, and this can lead to earlier removal of neck drains and safe discharge.

  15. The health workforce crisis: the brain drain scourge.

    PubMed

    Ike, Samuel O

    2007-01-01

    The magnitude of the health workforce crisis engendered by brain drain particularly in Africa, and nay more especially Nigeria, has been assuming increasingly alarming proportions in the past three decades. The challenge it poses in meeting the manpower needs in the healthcare sector as well as in the larger economy of the sending countries is enormous. This paper thus sets out to highlight the scope of this brain drain, its effects and the reasons sustaining it, as well as makes concrete suggestions to help stern the tide. A review of the literature on brain drain with particular emphasis on the health workforce sector was done, with focus on Africa, and specifically Nigeria. Literature search was done using mainly the Medline, as well as local journals. The historical perspectives, with the scope of external and internal brain drain are explored. The glaring effects of brain drain both in the global workforce terrain and specifically in the health sectors are portrayed. The countries affected most and the reasons for brain drain are outlined. Strategic steps to redress the brain drain crisis are proffered in this paper. The health workforce crisis resulting from brain drain must be brought to the front-burner of strategic policy decisions leading to paradigm shift in political, social and economic conditions that would serve as incentives to curb the scourge.

  16. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.

    PubMed

    Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho

    2011-05-01

    A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  17. Drain blocking: an effective treatment for reducing dissolved organic carbon loss and water discolouration in a drained peatland.

    PubMed

    Wallage, Zoe E; Holden, Joseph; McDonald, Adrian T

    2006-08-31

    Peatlands are an important terrestrial carbon store. However, heightened levels of degradation in response to environmental change have resulted in an increased loss of dissolved organic carbon (DOC) and an associated rise in the level of discolouration in catchment waters. A significant threat to peatland sustainability has been the installation of artificial drainage ditches. However, recent restoration schemes have pursued drain blocking as a possible strategy for reducing degradation, fluvial carbon loss and water discolouration. This paper investigates the effect of open cut drainage and the impact of drain blocking on DOC and colour dynamics in blanket peat soil-water solutions. Three treatments (intact peat, drained peat and drain-blocked peat) were monitored in an upland blanket peat catchment in the UK. DOC and colour values were significantly higher on the drained slopes compared with those of the intact peat, which in turn had greater DOC and colour values than the drain-blocked slopes. Consequently, drain blocking is shown to be a highly successful technique in reducing both the DOC concentration and level of discolouration in soil waters, even to values lower than those observed for the intact site, which suggests a process of store exhaustion and flushing may operate. The colour per carbon unit (C/C) ratio was significantly higher at the drain-blocked site than either the intact or the drained treatments, while the E4/E6 ratio (fulvic acid/humic acid) was significantly lower at the blocked site compared to the two other treatments. The high C/C and low E4/E6 ratios indicate that drain blocking also modifies the composition of DOC, such that darker-coloured humic substances become more dominant compared to the intact site. This implies disturbance to DOC production and/or transportation processes operating within the peat.

  18. Generation of airborne Listeria innocua from model floor drains.

    PubMed

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  19. Drain placement can be safely omitted after the majority of robotic partial nephrectomies.

    PubMed

    Abaza, Ronney; Prall, David

    2013-03-01

    Drain placement after partial nephrectomy is considered standard but it is based on routine and not on evidence. With experience we performed robotic partial nephrectomy and routinely omitted a drain even with significant collecting system violation. We have rarely used drains after robotic partial nephrectomy for several years, and we report our outcomes. We reviewed a single surgeon, prospective database of all robotic partial nephrectomies from February 2008 to March 2012, including the characteristics of those with and without a drain. The 150 patients underwent a total of 160 robotic partial nephrectomy procedures with a drain used in 11 patients and omitted in 93%. Mean patient age was 57 years (range 22 to 89), mean American Society of Anesthesiologists score was 2.8 (range 2 to 4) and mean body mass index was 32 kg/m(2) (range 18 to 54). Values were similar in patients with and without a drain. In patients without a drain and in those with a drain mean tumor size was 3.5 cm (range 1.0 to 11.0) and 4.6 cm (range 1.1 to 8.6), and mean R.E.N.A.L. (radius, exophytic/endophytic, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines, hilar tumor touching main renal artery or vein) nephrometry score was 7.8 (range 4 to 12) and 8.8 (range 6 to 11), respectively. Collecting system violation occurred in 88 patients (59%), including 78 without a drain. Two patients (1.3%) required transfusion with no intervention for bleeding. All except 5 patients (97%) were discharged home on postoperative day 1 with all drains removed before discharge. In 2 patients (1.3%) without a drain small urinomas without infection developed more than 2 weeks postoperatively, which were treated with a week of Foley catheter drainage and percutaneous drainage, respectively. Drain placement after robotic partial nephrectomy can be routinely omitted with a low rate of urine leaks, which can be managed safely when they rarely occur. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  1. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  2. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  3. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  4. Responses of Young Slash Pine on Poorly Drained to Somewhat Poorly Drained Silt Loam Soils to Site Preparation and Fertilization Treatments

    Treesearch

    James D. Haywood

    1995-01-01

    Slash pines (Pinus elliottii Engelm. var. elliottii) were planted on poorly drained Wrightsville and somewhat poorly drained Vidrine silt loam soils in southwest Louisiana. Neither flat disking nor bedding increased pine growth and yield substantially after nine growing seasons, but broadcast application of triple superphoshate...

  5. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58... Service 1 Equipment and Utensils § 58.416 Cheese vats, tanks and drain tables. (a) The vats, tanks and drain tables used for making cheese should be of metal construction with adequate jacket capacity for...

  6. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58... Service 1 Equipment and Utensils § 58.416 Cheese vats, tanks and drain tables. (a) The vats, tanks and drain tables used for making cheese should be of metal construction with adequate jacket capacity for...

  7. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a head-of-hollow... not located in an area containing intermittent or perennial streams. A rock-core chimney drain may be... is diverted around the fill. The alternative rock-core chimney drain system shall be incorporated...

  8. Method of draining water through a solid waste site without leaching

    DOEpatents

    Treat, Russell L.; Gee, Glendon W.; Whyatt, Greg A.

    1993-01-01

    The present invention is a method of preventing water from leaching solid waste sites by preventing atmospheric precipitation from contacting waste as the water flows through a solid waste site. The method comprises placing at least one drain hole through the solid waste site. The drain hole is seated to prevent waste material from entering the drain hole, and the solid waste site cover material is layered and graded to direct water to flow toward the drain hole and to soil beneath the waste site.

  9. Minimally invasive surgical technique for tethered surgical drains

    PubMed Central

    Hess, Shane R; Satpathy, Jibanananda; Waligora, Andrew C; Ugwu-Oju, Obinna

    2017-01-01

    A feared complication of temporary surgical drain placement is from the technical error of accidentally suturing the surgical drain into the wound. Postoperative discovery of a tethered drain can frequently necessitate return to the operating room if it cannot be successfully removed with nonoperative techniques. Formal wound exploration increases anesthesia and infection risk as well as cost and is best avoided if possible. We present a minimally invasive surgical technique that can avoid the morbidity associated with a full surgical wound exploration to remove a tethered drain when other nonoperative techniques fail. PMID:28400669

  10. Method of draining water through a solid waste site without leaching

    DOEpatents

    Treat, R.L.; Gee, G.W.; Whyatt, G.A.

    1993-02-02

    The present invention is a method of preventing water from leaching solid waste sites by preventing atmospheric precipitation from contacting waste as the water flows through a solid waste site. The method comprises placing at least one drain hole through the solid waste site. The drain hole is seated to prevent waste material from entering the drain hole, and the solid waste site cover material is layered and graded to direct water to flow toward the drain hole and to soil beneath the waste site.

  11. Abdominal drainage following cholecystectomy: high, low, or no suction?

    PubMed Central

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773

  12. Leakage current conduction in metal gate junctionless nanowire transistors

    NASA Astrophysics Data System (ADS)

    Oproglidis, T. A.; Karatsori, T. A.; Barraud, S.; Ghibaudo, G.; Dimitriadis, C. A.

    2017-05-01

    In this paper, the experimental off-state drain leakage current behavior is systematically explored in n- and p-channel junctionless nanowire transistors with HfSiON/TiN/p+-polysilicon gate stack. The analysis of the drain leakage current is based on experimental data of the gate leakage current. It has been shown that the off-state drain leakage current in n-channel devices is negligible, whereas in p-channel devices it is significant and dramatically increases with drain voltage. The overall results indicate that the off-state drain leakage current in p-channel devices is mainly due to trap-assisted Fowler-Nordheim tunneling of electrons through the gate oxide of electrons from the metal gate to the silicon layer near the drain region.

  13. Improved long-term survival with subdural drains following evacuation of chronic subdural haematoma.

    PubMed

    Guilfoyle, Mathew R; Hutchinson, Peter J A; Santarius, Thomas

    2017-05-01

    Chronic subdural haematoma (CSDH) is a common condition that is effectively managed by burrhole drainage but requires repeat surgery in a significant minority of patients. The Cambridge Chronic Subdural Haematoma Trial (CCSHT) was a randomised controlled study that showed placement of subdural drains for 48 h following burrhole evacuation significantly reduces the incidence of reoperation and improves survival at 6 months. The present study examined the long-term survival of the patients in the trial. In the original trial patients at a single neurosurgical centre from 2004-2007 were randomly assigned to receive a drain (n = 108) or no drain (n = 107) following burrhole drainage of CSDH. We ascertained whether the trial patients were alive in February 2016-a minimum of 8 years following enrollment-via the UK NHS tracing service. Survival was compared between the trial groups and against expected survival for the UK general population matched for age and sex. At 5 years following surgery the drain group continued to have significantly better survival than the no drain patients (p = 0.027), but this was no longer apparent at 10 years. Survival of patients in the drain group did not differ significantly from that of the general population whereas patients who did not receive a drain had significantly lower survival than expected (p = 0.0006). Subdural drains following CSDH evacuation are associated with improved long-term survival, which appears similar to that expected for the general population of the same age and sex. All patients having burrhole CSDH evacuation should receive a drain as standard practice unless specifically contraindicated.

  14. A novel method for electronic measurement and recording of surgical drain output.

    PubMed

    van Duren, Bernard Hendrik; van Boxel, Gijsbert Isaac

    2017-04-01

    Surgical drains are used to collect and measure fluids (e.g. serous fluid, lymph, blood, etc.). The volume of fluid in the container is measured using graded markings on the container and then recorded manually on a "drain chart" allowing for manual rate calculations. This method is dependant on regularly checking the volume of the drain and recording the value accurately; unfortunately, this is often not feasible due to staffing levels and time constraints. This results in inaccurate "drain charts" making clinical decisions based on these figures unreliable. Often the lack of confidence in these measurements leads to delayed drain removal with consequent increased infection risks and potential delayed discharge. Accurate digital measurement of drain content would have a significant impact on clinical care. This paper describes a digital technology to measure volume, making use of a positive terminal at the lowest point of the vessel and negative (sensor) terminals placed at accurate intervals along an axis of the vessel. A proof-of-concept prototype was developed using commercially available electronic components to test the feasibility of a technology for electronic measurement and recording of surgical drain content. In a simulated environment, the proposed technology was shown to be effective and accurate. The proposed electronic drain has a number of advantages over currently used devices in saving time and easing pressure on nursing staff, reduce disturbance of patients, and allows for preset alarms.

  15. Short-Channel Tunneling Field-Effect Transistor with Drain-Overlap and Dual-Metal Gate Structure for Low-Power and High-Speed Operations.

    PubMed

    Yoon, Young Jun; Eun, Hye Rim; Seo, Jae Hwa; Kang, Hee-Sung; Lee, Seong Min; Lee, Jeongmin; Cho, Seongjae; Tae, Heung-Sik; Lee, Jung-Hee; Kang, In Man

    2015-10-01

    We have investigated and proposed a highly scaled tunneling field-effect transistor (TFET) based on Ge/GaAs heterojunction with a drain overlap to suppress drain-induced barrier thinning (DIBT) and improve low-power (LP) performance. The highly scaled TFET with a drain overlap achieves lower leakage tunneling current because of the decrease in tunneling events between the source and drain, whereas a typical short-channel TFET suffers from a great deal of tunneling leakage current due to the DIBT at the off-state. However, the drain overlap inevitably increases the gate-to-drain capacitance (Cgd) because of the increase in the overlap capacitance (Cov) and inversion capacitance (Cinv). Thus, in this work, a dual-metal gate structure is additionally applied along with the drain overlap. The current performance and the total gate capacitance (Cgg) of the device with a dual-metal gate can be possibly controlled by adjusting the metal gate workfunction (φgate) and φoverlap-gate in the overlapping regions. As a result, the intrinsic delay time (τ) is greatly reduced by obtaining lower Cgg divided by the on-state current (Ion), i.e., Cgg/Ion. We have successfully demonstrated excellent LP and high-speed performance of a highly scaled TFET by adopting both drain overlap and dual-metal gate with DIBT minimization.

  16. Water table dynamics in undisturbed, drained and restored blanket peat

    NASA Astrophysics Data System (ADS)

    Holden, J.; Wallage, Z. E.; Lane, S. N.; McDonald, A. T.

    2011-05-01

    SummaryPeatland water table depth is an important control on runoff production, plant growth and carbon cycling. Many peatlands have been drained but are now subject to activities that might lead to their restoration including the damming of artificial drains. This paper investigates water table dynamics on intact, drained and restored peatland slopes in a blanket peat in northern England using transects of automated water table recorders. Long-term (18 month), seasonal and short-term (storm event) records are explored. The restored site had drains blocked 6 years prior to monitoring commencing. The spatially-weighted mean water table depths over an 18 month period were -5.8 cm, -8.9 cm and -11.5 cm at the intact, restored and drained sites respectively. Most components of water table behaviour at the restored site, including depth exceedance probability curves, seasonality of water table variability, and water table responses to individual rainfall events were intermediate between that of the drained and intact sites. Responses also depended on location with respect to the drains. The results show that restoration of drained blanket peat is difficult and the water table dynamics may not function in the same way as those in undisturbed blanket peat even many years after management intervention. Further measurement of hydrological processes and water table responses to peatland restoration are required to inform land managers of the hydrological success of those projects.

  17. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    PubMed Central

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of <10 years, low-rank nurses and those working in the female medical ward; however, the relationship cant (P > 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  18. Growth and Seed Production of Sawtooth Oak (Quercus acutissima) 22 Years After Direct Seeding

    Treesearch

    J.C.G. Goelz; D.W. Carlson

    1997-01-01

    Sawtooth oak (Quercus acutissima Carruth.) was direct seeded at two locations, one with a poorly drained clay soil and the other with a well-drained silty clay loam. For comparison, Nuttall oak (Q. nuttallii Palmer) was direct seeded on the poorly drained clay soil. On the well-drained silty clay loam, sawtooth oak was 18 ft...

  19. Interaction of the Bored Sand and Gravel Drain Pile with the Surrounding Compacted Loam Soil and Foundation Raft Taking into Account Rheological Properties of the Loam Soil and Non-Linear Properties of the Drain Pile

    NASA Astrophysics Data System (ADS)

    Ter-Martirosyan, Z. G.; Ter-Martirosyan, A. Z.; Anzhelo, G. O.; Buslov, A. S.

    2018-01-01

    The task of the interaction of the sand and gravel drain pile with the surrounding loam soil after its preliminary deep compaction and formation of the composite ground cylinder from the drain pile and surrounding compacted loam soil (cells) is considered in the article. It is seen that the subsidence and carrying capacity of such cell considerably depends on physical and mechanical properties of the compacted drain piles and surrounding loam soil as well as their diameter and intercellular distance. The strain-stress state of the cell is considered not taking into account its component elements, but taking into account linear and elastic-plastic properties of the drain pile and creep flow of the surrounding loam soil. It is stated that depending on these properties the distribution and redistribution of the load on a cell takes place from the foundation raft between the drain pile and surrounding soil. Based on the results of task solving the formulas and charts are given demonstrating the ratio of the load between the drain pile and surrounding loam soil in time.

  20. Si1-yGey or Ge1-zSnz Source/Drain Stressors on Strained Si1-xGex-Channel P-Type Field-Effect Transistors: A Technology Computer-Aided Design Study

    NASA Astrophysics Data System (ADS)

    Eneman, Geert; De Keersgieter, An; Witters, Liesbeth; Mitard, Jerome; Vincent, Benjamin; Hikavyy, Andriy; Loo, Roger; Horiguchi, Naoto; Collaert, Nadine; Thean, Aaron

    2013-04-01

    The interaction between two stress techniques, strain-relaxed buffers (SRBs) and epitaxial source/drain stressors, is studied on short, Si1-xGex- and Ge-channel planar transistors. This work focuses on the longitudinal channel stress generated by these two techniques. Unlike for unstrained silicon-channel transistors, for strained channels on top of a strain-relaxed buffer a source/drain stressor without recess generates similar longitudinal channel stress than source/drain stressors with a deep recess. The least efficient stress transfer is obtained for source/drain stressors with a small recess that removes only the strained channel, not the substrate underneath. These trends are explained by a trade-off between elastic relaxation of the strained-channel during source/drain recess and the increased stress generation of thicker source/drain stressors. For Ge-channel pFETs, GeSn source/drains and Si1-xGex strain-relaxed buffers are efficient stressors for mobility enhancement. The former is more efficient for gate-last schemes than for gate-first, while the stress generated by the SRB is found to be independent of the gate-scheme.

  1. Enhanced performance of amorphous In-Ga-Zn-O thin-film transistors using different metals for source/drain electrodes

    NASA Astrophysics Data System (ADS)

    Pyo, Ju-Young; Cho, Won-Ju

    2017-09-01

    In this paper, we propose an amorphous indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) with off-planed source/drain electrodes. We applied different metals for the source/drain electrodes with Ni and Ti to control the work function as high and low. When we measured the configuration of Ni to drain and source to Ti, the a-IGZO TFT showed increased driving current, decreased leakage current, a high on/off current ratio, low subthreshold swing, and high mobility. In addition, we conducted a reliability test with a gate bias stress test at various temperatures. The results of the reliability test showed the Ni drain and Ti drain had an equivalent effective energy barrier height. Thus, we confirmed that the proposed off-planed structure improved the electrical characteristics of the fabricated devices without any degradation of characteristics. Through the a-IGZO TFT with different source/drain electrode metal engineering, we realized high-performance TFTs for next-generation display devices.

  2. Necessity of suction drains in gynecomastia surgery.

    PubMed

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  3. Hot-Electron-Induced Device Degradation during Gate-Induced Drain Leakage Stress

    NASA Astrophysics Data System (ADS)

    Kim, Kwang-Soo; Han, Chang-Hoon; Lee, Jun-Ki; Kim, Dong-Soo; Kim, Hyong-Joon; Shin, Joong-Shik; Lee, Hea-Beoum; Choi, Byoung-Deog

    2012-11-01

    We studied the interface state generation and electron trapping by hot electrons under gate-induced drain leakage (GIDL) stress in p-type metal oxide semiconductor field-effect transistors (P-MOSFETs), which are used as the high-voltage core circuit of flash memory devices. When negative voltage was applied to a drain in the off-state, a GIDL current was generated, but when high voltage was applied to the drain, electrons had a high energy. The hot electrons produced the interface state and electron trapping. As a result, the threshold voltage shifted and the off-state leakage current (trap-assisted drain junction leakage current) increased. On the other hand, electron trapping mitigated the energy band bending near the drain and thus suppressed the GIDL current generation.

  4. Jet-controlled freeze valve for use in a glass melter

    DOEpatents

    Routt, K.R.

    1985-07-29

    A drain valve for use in furnace for the melting of thermoplastic material is disclosed. The furnace includes a drain cavity formed in its bottom for withdrawing a flow of thermoplastic material. The drain valve includes a flow member which include a flow tube having an inlet and outlet for the material, and coaxially disposed concentric tubular members defining annuli surrounding the flow tube. The tubular members include heating and cooling means for the flow tube. The drain valve can also be used in a furnace of glass melting that includes a drain cavity for withdrawing molten glass from the furnace.

  5. Effect of an intervention in storm drains to prevent Aedes aegypti reproduction in Salvador, Brazil.

    PubMed

    Souza, Raquel Lima; Mugabe, Vánio André; Paploski, Igor Adolfo Dexheimer; Rodrigues, Moreno S; Moreira, Patrícia Sousa Dos Santos; Nascimento, Leile Camila Jacob; Roundy, Christopher Michael; Weaver, Scott C; Reis, Mitermayer Galvão; Kitron, Uriel; Ribeiro, Guilherme Sousa

    2017-07-11

    Aedes aegypti, the principal vector for dengue, chikungunya and Zika viruses, is a synanthropic species that uses stagnant water to complete its reproductive cycle. In urban settings, rainfall water draining structures, such as storm drains, may retain water and serve as a larval development site for Aedes spp. reproduction. Herein, we describe the effect of a community-based intervention on preventing standing water accumulation in storm drains and their consequent infestation by adult and immature Ae. aegypti and other mosquitoes. Between April and May of 2016, local residents association of Salvador, Brazil, after being informed of water accumulation and Ae. aegypti infestation in the storm drains in their area, performed an intervention on 52 storm drains. The intervention consisted of placing concrete at the bottom of the storm drains to elevate their base to the level of the outflow tube, avoiding water accumulation, and placement of a metal mesh covering the outflow tube to avoid its clogging with debris. To determine the impact of the intervention, we compared the frequency at which the 52 storm drains contained water, as well as adult and immature mosquitoes using data from two surveys performed before and two surveys performed after the intervention. During the pre-intervention period, water accumulated in 48 (92.3%) of the storm drains, and immature Ae. aegypti were found in 11 (21.2%) and adults in 10 (19.2%). After the intervention, water accumulated in 5 (9.6%) of the storm drains (P < 0.001), none (0.0%) had immatures (P < 0.001), and 3 (5.8%) contained adults (P = 0.039). The total number of Ae. aegypti immatures collected decreased from 109 to 0 (P < 0.001) and adults decreased from 37 to 8 (P = 0.011) after the intervention. Collection of immature and adult non-Aedes mosquitoes (mainly Culex spp.) in the storm drains also decreased after the intervention. This study exemplifies how a simple intervention targeting storm drains can result in a major reduction of water retention, and, consequently, impact Ae. aegypti larval populations. Larger and multi-center evaluations are needed to confirm the potential of citywide structural modifications of storm drains to reduce Aedes spp. infestation level.

  6. Intra-abdominal drain fracture following pancreatic necrosectomy.

    PubMed

    Campbell, W; Wallace, W; Gibson, E; McCallion, K

    2011-06-01

    We describe a rare case of iatrogenic fracture of an intra-abdominal tube drain (Portex Robinson drain, Smiths Medical, Kent, UK) in a 74-year-old man. The fracture occurred at the level of an additionally placed fenestration and was identified on CT scanning prior to retrieval at planned re-laparotomy. This case highlights the potential dangers of modifying pre-formed drains and recommends against this practice.

  7. Effectiveness of Postoperative Wound Drains in One- and Two-Level Cervical Spine Fusions

    PubMed Central

    Poorman, Caroline E.; Bianco, Kristina M.; Boniello, Anthony; Yang, Sun; Gerling, Michael C.

    2014-01-01

    Background Cervical drains have historically been used to avoid postoperative wound and respiratory complications such as excessive edema, hematoma, infection, re-intubation, delayed extubation, or respiratory distress. Recently, some surgeons have ceased using drains because they may prolong hospital stay, operative time, or patient discomfort. The objective of this retrospective case-control series is to investigate the effectiveness of postoperative drains following one- and two-level cervical fusions. Methods A chart review was conducted at a single institution from 2010-2013. Outcome measures included operative time, hospital stay, estimated blood loss and incidence of wound complications (infection, hematoma, edema, and complications with wound healing or evacuation), respiratory complications (delayed extubation, re-intubation, and respiratory treatment), and overall complications (wound complications, respiratory complications, dysphagia, and other complications). Statistical analyses including independent samples t-test, chi-square, analysis of covariance, and linear regression were used to compare patients who received a postoperative drain to those who did not. Results The study population included 39 patients who received a postoperative drain and 42 patients who did not. There were no differences in demographics between the two groups. Patients with drains showed increased operative time (100.1 vs 69.3 min, p < 0.001), hospital stay (38.9 vs. 31.7 hrs, p = 0.021), and blood loss (62.7 vs 29.1 mL, p < 0.001) compared to patients without drains. The frequency of wound complications, respiratory complications, and overall complications did not vary significantly between groups. Conclusions/Level of Evidence Cervical drains may not be necessary for patients undergoing one- and two-level cervical fusion. While there were no differences in incidence of complications between groups, patients treated with drains had significantly longer operative time and length of hospital stay. Clinical relevance This could contribute to excessive costs for patients treated with drains, despite the lack of compelling evidence of the advantages of this treatment in the literature and in the current study. PMID:25694927

  8. Remote sensing for assessing the zone of benefit where deep drains improve productivity of land affected by shallow saline groundwater.

    PubMed

    Kobryn, H T; Lantzke, R; Bell, R; Admiraal, R

    2015-03-01

    The installation of deep drains is an engineering approach to remediate land salinised by the influence of shallow groundwater. It is a costly treatment and its economic viability is, in part, dependent on the lateral extent to which the drain increases biological productivity by lowering water tables and soil salinity (referred to as the drains' zone of benefit). Such zones may be determined by assessing the biological productivity response of adjacent vegetation over time. We tested a multi-temporal satellite remote sensing method to analyse temporal and spatial changes in vegetation condition surrounding deep drainage sites at five locations in the Western Australian wheatbelt affected by dryland salinity-Morawa, Pithara, Beacon, Narembeen and Dumbleyung. Vegetation condition as a surrogate for biological productivity was assessed by Normalised Difference Vegetation Index (NDVI) during the peak growing season. Analysis was at the site scale within a 1000 m buffer zone from the drains. There was clear evidence of NDVI increasing with elevation, slope and distance from the drain. After accounting for elevation, slope and distance from the drain, there was a significant increase in NDVI across the five locations after installation of deep drains. Changes in NDVI after drainage were broadly consistent with measured changes at each site in groundwater levels after installation of the deep drains. However, this study assessed the lateral extent of benefit for biological productivity and gave a measure of the area of benefit along the entire length of the drain. The method demonstrated the utility of spring NDVI images for rapid and relatively simple assessment of the change in site condition after implementation of drainage, but approaches for further improvement of the procedure were identified. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Quantification of non-stormwater flow entries into storm drains using a water balance approach.

    PubMed

    Xu, Zuxin; Yin, Hailong; Li, Huaizheng

    2014-07-15

    To make decisions about correcting illicit or inappropriate connections to storm drains, quantification of non-stormwater entries into storm drains was performed using a water flow balance approach, based on data analysis from 2008 to 2011 in a separate storm drainage system in a Shanghai downtown area of 374 ha. The study revealed severe sewage connections to storm drains; meanwhile, misconnections between surface water and storm drains were found to drive frequent non-stormwater pumping discharges at the outfall, producing a much larger volume of outfall flows in a short period. This paper presented a methodology to estimate quantities of inappropriate sewage flow, groundwater infiltration and river water backflow into the storm drains. It was concluded that inappropriate sewage discharge and groundwater seepage into storm drains were approximately 17,860 m(3)/d (i.e., up to 51% of the total sewage flow in the catchment) and 3,624 m(3)/d, respectively, and surface water backflow was up to an average 28,593 m(3)/d. On the basis of this work, end-of-storm pipe interceptor sewers of 0.25 m(3)/s (i.e., 21,600 m(3)/d) would be effective to tackle the problem of sewage connections and groundwater seepage to storm drains. Under this circumstance, the follow-up non-stormwater outfall pumping events indicate misconnections between surface water and storm drains, featuring pumping discharge equivalent to surface water backflow; hence the misconnections should be repaired. The information provided here is helpful in estimating the magnitude of non-stormwater flow entries into storm drains and designing the necessary pollution control activities, as well as combating city floods in storm events. Copyright © 2014. Published by Elsevier B.V.

  10. Continuous 'Passive' Registration of Non-Point Contaminant Loads Via Agricultural Subsurface Drain Tubes

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J.; Jansen, S.; de Jonge, H.; Lindblad Vendelboe, A.

    2014-12-01

    Considering their crucial role in water and solute transport, enhanced monitoring and modeling of agricultural subsurface tube drain systems is important for adequate water quality management. For example, previous work in lowland agricultural catchments has shown that subsurface tube drain effluent contributed up to 80% of the annual discharge and 90-92% of the annual NO3 loads from agricultural fields towards the surface water. However, existing monitoring techniques for flow and contaminant loads from tube drains are expensive and labor-intensive. Therefore, despite the unambiguous relevance of this transport route, tube drain monitoring data are scarce. The presented study aimed developing a cheap, simple, and robust method to monitor loads from tube drains. We are now ready to introduce the Flowcap that can be attached to the outlet of tube drains and is capable of registering total flow, contaminant loads, and flow-averaged concentrations. The Flowcap builds on the existing SorbiCells, a modern passive sampling technique that measures average concentrations over longer periods of time (days to months) for various substances. By mounting SorbiCells in our Flowcap, a flow-proportional part of the drain effluent is sampled from the main stream. Laboratory testing yielded good linear relations (R-squared of 0.98) between drainage flow rates and sampling rates. The Flowcap was tested in practice for measuring NO3 loads from two agricultural fields and one glasshouse in the Netherlands. The Flowcap registers contaminant loads from tube drains without any need for housing, electricity, or maintenance. This enables large-scale monitoring of non-point contaminant loads via tube drains, which would facilitate the improvement of contaminant transport models and would yield valuable information for the selection and evaluation of mitigation options to improve water quality.

  11. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  12. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  13. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  14. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  15. 40 CFR 60.692-2 - Standards: Individual drain systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emissions From Petroleum Refinery Wastewater Systems § 60.692-2 Standards: Individual drain systems. (a)(1... section. (e) Refinery wastewater routed through new process drains and a new first common downstream...

  16. The fabrication of carbon nanotube field-effect transistors with semiconductors as the source and drain contact materials.

    PubMed

    Xiao, Z; Camino, F E

    2009-04-01

    Sb(2)Te(3) and Bi(2)Te(2)Se semiconductor materials were used as the source and drain contact materials in the fabrication of carbon nanotube field-effect transistors (CNTFETs). Ultra-purified single-walled carbon nanotubes (SWCNTs) were ultrasonically dispersed in N-methyl pyrrolidone solvent. Dielectrophoresis was used to deposit and align SWCNTs for fabrication of CNTFETs. The Sb(2)Te(3)- and Bi(2)Te(2)Se-based CNTFETs demonstrate p-type metal-oxide-silicon-like I-V curves with high on/off drain-source current ratio at large drain-source voltages and good saturation of drain-source current with increasing drain-source voltage. The fabrication process developed is novel and has general meaning, and could be used for the fabrication of SWCNT-based integrated devices and systems with semiconductor contact materials.

  17. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  18. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    PubMed

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P < 0.05). The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  19. Carbon Dioxide Flux from Rice Paddy Soils in Central China: Effects of Intermittent Flooding and Draining Cycles

    PubMed Central

    Liu, Yi; Wan, Kai-yuan; Tao, Yong; Li, Zhi-guo; Zhang, Guo-shi; Li, Shuang-lai; Chen, Fang

    2013-01-01

    A field experiment was conducted to (i) examine the diurnal and seasonal soil carbon dioxide (CO2) fluxes pattern in rice paddy fields in central China and (ii) assess the role of floodwater in controlling the emissions of CO2 from soil and floodwater in intermittently draining rice paddy soil. The soil CO2 flux rates ranged from −0.45 to 8.62 µmol.m−2.s−1 during the rice-growing season. The net effluxes of CO2 from the paddy soil were lower when the paddy was flooded than when it was drained. The CO2 emissions for the drained conditions showed distinct diurnal variation with a maximum efflux observed in the afternoon. When the paddy was flooded, daytime soil CO2 fluxes reversed with a peak negative efflux just after midday. In draining/flooding alternating periods, a sudden pulse-like event of rapidly increasing CO2 efflux occured in response to re-flooding after draining. Correlation analysis showed a negative relation between soil CO2 flux and temperature under flooded conditions, but a positive relation was found under drained conditions. The results showed that draining and flooding cycles play a vital role in controlling CO2 emissions from paddy soils. PMID:23437170

  20. Drain amylase aids detection of anastomotic leak after esophagectomy.

    PubMed

    Baker, Erin H; Hill, Joshua S; Reames, Mark K; Symanowski, James; Hurley, Susie C; Salo, Jonathan C

    2016-04-01

    Anastomotic leak following esophagectomy is associated with significant morbidity and mortality. As hospital length of stay decreases, the timely diagnosis of leak becomes more important. We evaluated CT esophagram, white blood count (WBC), and drain amylase levels in the early detection of anastomotic leak. The diagnostic performance of CT esophagram, drain amylase >800 IU/L, and WBC >12,000/µL within the first 10 days after surgery in predicting leak at any time after esophagectomy was calculated. Anastomotic leak occurred in 13 patients (13%). CT esophagram performed within 10 days of surgery diagnosed six of these leaks with a sensitivity of 0.54. Elevation in drain amylase level within 10 days of surgery diagnosed anastomotic leak with a sensitivity of 0.38. When the CT esophagram and drain amylase were combined, the sensitivity rose to 0.69 with a specificity of 0.98. WBC elevation had a sensitivity of 0.92, with a specificity of 0.34. Among 30 patients with normal drain amylase and a normal WBC, one developed an anastomotic leak. Drain amylase adds to the sensitivity of CT esophagram in the early detection of anastomotic leak. Selected patients with normal drain amylase levels and normal WBC may be able to safely forgo CT esophagram.

  1. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    PubMed Central

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  2. Thoracic Trauma: Which Chest Tube When and Where?

    PubMed

    Molnar, Tamas F

    2017-02-01

    Clinical suspicion of hemo/pneumothorax: when in doubt, drain the chest. Stable chest trauma with hemo/pneumothorax: drain and wait. Unstable patient with dislocated trachea must be approached with drain in hand and scalpel ready. Massive hemo/pneumothorax may be controlled by drainage alone. The surgeon should not hesitate to open the chest if too much blood drains over a short period. The chest drainage procedure does not end with the last stitch; the second half of the match is still ahead. The drained patient is in need of physiotherapy and proper pain relief with an extended pleural space: control the suction system. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Numerical Simulation of Liquids Draining From a Tank Using OpenFOAM

    NASA Astrophysics Data System (ADS)

    Sakri, Fadhilah Mohd; Sukri Mat Ali, Mohamed; Zaki Shaikh Salim, Sheikh Ahmad; Muhamad, Sallehuddin

    2017-08-01

    Accurate simulation of liquids draining is a challenging task. It involves two phases flow, i.e. liquid and air. In this study draining a liquid from a cylindrical tank is numerically simulated using OpenFOAM. OpenFOAM is an open source CFD package and it becomes increasingly popular among the academician and also industries. Comparisons with theoretical and results from previous published data confirmed that OpenFOAM is able to simulate the liquids draining very well. This is done using the gas-liquid interface solver available in the standard library of OpenFOAM. Additionally, this study was also able to explain the physics flow of the draining tank.

  4. Data on Streamflow and Quality of Water and Bottom Sediment in and near Humboldt Wildlife Management Area, Churchill and Pershing Counties, Nevada, 1998-2000

    USGS Publications Warehouse

    Paul, Angela P.; Thodal, Carl E.

    2003-01-01

    This study was initiated to expand upon previous findings that indicated concentrations of dissolved solids, arsenic, boron, mercury, molybdenum, selenium, and uranium were either above geochemical background concentrations or were approaching or exceeding ecological criteria in the lower Humboldt River system. Data were collected from May 1998 to September 2000 to further characterize streamflow and surface-water and bottom-sediment quality in the lower Humboldt River, selected agricultural drains, Upper Humboldt Lake, and Lower Humboldt Drain (ephemeral outflow from Humboldt Sink). During this study, flow in the lower Humboldt River was either at or above average. Flows in Army and Toulon Drains generally were higher than reported in previous investigations. An unnamed agricultural drain contributed a small amount to the flow measured in Army Drain. In general, measured concentrations of sodium, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium were higher in water from agricultural drains than in Humboldt River water during this study. Mercury concentrations in water samples collected during the study period typically were below the laboratory reporting level. However, low-level mercury analyses showed that samples collected in August 1999 from Army Drain had higher mercury concentrations than those collected from the river or Toulon Drain or the Lower Humboldt Drain. Ecological criteria and effect concentrations for sodium, chloride, dissolved solids, arsenic, boron, mercury, and molybdenum were exceeded in some water samples collected as part of this study. Although water samples from the agricultural drains typically contained higher concentrations of sodium, chloride, dissolved solids, arsenic, boron, and uranium, greater instantaneous loads of these constituents were carried in the river near Lovelock than in agricultural drains during periods of high flow or non-irrigation. During this study, the high flows in the lower Humboldt River produced the maximum instantaneous loads of sodium, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium at all river-sampling sites, except molybdenum near Imlay. Nevada Division of Environmental Protection monitoring reports on mine-dewatering discharge for permitted releases of treated effluent to the surface waters of the Humboldt River and its tributaries were reviewed for reported discharges and trace-element concentrations from June 1998 to September 1999. These data were compared with similar information for the river near Imlay. In all bottom sediments collected for this study, arsenic concentrations exceeded the Canadian Freshwater Interim Sediment-Quality Guideline for the protection of aquatic life and probable-effect level (concentration). Sediments collected near Imlay, Rye Patch Reservoir, Lovelock, and from Toulon Drain and Army Drain were found to contain cadmium and chromium concentrations that exceeded Canadian criteria. Chromium concentrations in sediments collected from these sites also exceeded the consensus-based threshold-effect concentration. The Canadian criterion for sediment copper concentration was exceeded in sediments collected from the Humboldt River near Lovelock and from Toulon, Army, and the unnamed agricultural drains. Mercury in sediments collected near Imlay and from Toulon Drain in August 1999 exceeded the U.S. Department of the Interior sediment probable-effect level. Nickel concentrations in sediments collected during this study were above the consensus-based threshold-effect concentration. All other river and drain sediments had constituent concentrations below protective criteria and toxicity thresholds. In Upper Humboldt Lake, chloride, dissolved solids, arsenic, boron, molybdenum, and uranium concentrations in surface-water samples collected near the mouth of the Humboldt River generally were higher than in samples collected near the mouth of Army Drain. Ecological criteria or effect con

  5. Closed flume inlet efficiency : [summary].

    DOT National Transportation Integrated Search

    2014-04-01

    The storm drain is an inconspicuous but critical : part of the roadway, especially in Florida. Drains : look deceptively simple, but they must capture : water as efficiently as possible. To help assure : the performance of storm drains, the Florida :...

  6. Statistical variability study of random dopant fluctuation on gate-all-around inversion-mode silicon nanowire field-effect transistors

    NASA Astrophysics Data System (ADS)

    Yoon, Jun-Sik; Rim, Taiuk; Kim, Jungsik; Kim, Kihyun; Baek, Chang-Ki; Jeong, Yoon-Ha

    2015-03-01

    Random dopant fluctuation effects of gate-all-around inversion-mode silicon nanowire field-effect transistors (FETs) with different diameters and extension lengths are investigated. The nanowire FETs with smaller diameter and longer extension length reduce average values and variations of subthreshold swing and drain-induced barrier lowering, thus improving short channel immunity. Relative variations of the drain currents increase as the diameter decreases because of decreased current drivability from narrower channel cross-sections. Absolute variations of the drain currents decrease critically as the extension length increases due to decreasing the number of arsenic dopants penetrating into the channel region. To understand variability origins of the drain currents, variations of source/drain series resistance and low-field mobility are investigated. All these two parameters affect the variations of the drain currents concurrently. The nanowire FETs having extension lengths sufficient to prevent dopant penetration into the channel regions and maintaining relatively large cross-sections are suggested to achieve suitable short channel immunity and small variations of the drain currents.

  7. Cleanup Verification Package for the 118-H-6:2, 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils; the 118-H-6:3, 105-H Reactor Fuel Storage Basin and Underlying Soils; The 118-H-6:3 Fuel Storage Basin Deep Zone Side Slope Soils; the 100-H-9, 100-H-10, and 100-H-13 French Drains; the 100-H-11 and 100-H-12 Expansion Box French Drains; and the 100-H-14 and 100-H-31 Surface Contamination Zones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. J. Appel

    2006-06-29

    This cleanup verification package documents completion of removal actions for the 105-H Reactor Ancillary Support Areas, Below-Grade Structures, and Underlying Soils (subsite 118-H-6:2); 105-H Reactor Fuel Storage Basin and Underlying Soils (118-H-6:3); and Fuel Storage Basin Deep Zone Side Slope Soils. This CVP also documents remedial actions for the following seven additional waste sties: French Drain C (100-H-9), French Drain D (100-H-10), Expansion Box French Drain E (100-H-11), Expansion Box French Drain F (100-H-12), French Drain G (100-H-13), Surface Contamination Zone H (100-H-14), and the Polychlorinated Biphenyl Surface Contamination Zone (100-H-31).

  8. Randomised clinical trial of chest drainage systems.

    PubMed Central

    Graham, A N; Cosgrove, A P; Gibbons, J R; McGuigan, J A

    1992-01-01

    BACKGROUND: Problems in the management of thoracic trauma have stimulated the search for an alternative to underwater seals for drainage of the pleural cavity. A chest drainage bag incorporating a one way flutter valve has been compared with underwater seal drains in a randomised clinical trial. METHODS: During June-December 1989 119 patients undergoing elective thoracotomy were randomised to receive postoperative chest drainage by drainage bags (56 patients, 87 drains) or by underwater seal drains (63 patients, 98 drains). Daily drainage volumes, the requirement for pleural suction, mobility, and complications were recorded prospectively. RESULTS: There was no significant difference between the two groups in the mean volume drained, the requirements for pleural suction, or the occurrence of complications. Patients with drainage bags were fully mobile 23 hours (95% confidence interval 0-47 hours) earlier than the others. CONCLUSIONS: When used after elective thoracotomy drainage bags are safe and effective and permit earlier mobility than underwater seal drains. PMID:1496507

  9. p-MOSFET total dose dosimeter

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  10. Corrective Action Plan for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2011-04-30

    This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 562, Waste Systems, in accordance with the Federal Facility Agreement and Consent Order (1996; as amended March 2010). CAU 562 consists of 13 Corrective Action Sites (CASs) located in Areas 2, 23, and 25 of the Nevada National Security Site. Site characterization activities were performed in 2009 and 2010, and the results are presented in Appendix A of the Corrective Action Decision Document for CAU 562. The scope of work required to implement the recommended closure alternatives is summarized. (1) CAS 02-26-11, Lead Shot, will be clean closedmore » by removing shot. (2) CAS 02-44-02, Paint Spills and French Drain, will be clean closed by removing paint and contaminated soil. As a best management practice (BMP), asbestos tile will be removed. (3) CAS 02-59-01, Septic System, will be clean closed by removing septic tank contents. As a BMP, the septic tank will be removed. (4) CAS 02-60-01, Concrete Drain, contains no contaminants of concern (COCs) above action levels. No further action is required; however, as a BMP, the concrete drain will be removed. (5) CAS 02-60-02, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. As a BMP, the drain grates and drain pipe will be removed. (6) CAS 02-60-03, Steam Cleaning Drain, will be clean closed by removing contaminated soil. As a BMP, the steam cleaning sump grate and outfall pipe will be removed. (7) CAS 02-60-04, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. (8) CAS 02-60-05, French Drain, will be clean closed by removing contaminated soil. (9) CAS 02-60-06, French Drain, contains no COCs above action levels. No further action is required. (10) CAS 02-60-07, French Drain, requires no further action. The french drain identified in historical documentation was not located during corrective action investigation activities. (11) CAS 23-60-01, Mud Trap Drain and Outfall, will be clean closed by removing sediment from the mud trap. As a BMP, the mud trap and outfall pipe will be removed. (12) CAS 23-99-06, Grease Trap, will be clean closed by removing sediment from the grease trap and backfilling the grease trap with grout. (13) CAS 25-60-04, Building 3123 Outfalls, will be clean closed by removing contaminated soil and the sludge-containing outfall pipe.« less

  11. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study.

    PubMed

    Kumar, Barun; Bhate, Kalyani; Dolas, R S; Kumar, Sn Santhosh; Waknis, Pushkar

    2016-12-01

    Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus.

  12. Abdominal Drainage and Amylase Measurement for Detection of Leakage After Gastrectomy for Gastric Cancer.

    PubMed

    Schots, Judith P M; Luyer, Misha D P; Nieuwenhuijzen, Grard A P

    2018-05-07

    To investigate the value of daily measurement of drain amylase for detecting leakage in gastric cancer surgery. This was a retrospective analysis including all patients who underwent a gastrectomy for gastric cancer. From January 2013 until December 2015, an intra-abdominal drain was routinely placed. Drain amylase was measured daily. Receiver operator characteristic curves were created to assess the ability of amylase to predict leakage. Sensitivity, specificity, and negative and positive predictive value of amylase in drain fluid were determined. Leakage of the gastrojejunostomy or esophagojejunostomy, enteroenterostomy, duodenal stump, or pancreas was diagnosed by CT scan, endoscopy, or during re-operation. From January 2016 until April 2017, no drain was inserted. Surgical outcome and postoperative complications were compared between both groups. Median drain amylase concentrations were higher for each postoperative day in patients with leakage. The optimal cutoff value was 1000 IU/L (sensitivity 77.8%, specificity 98.2%, negative predictive value 96.6%). Sixty-seven consecutive procedures were performed with a drain and 40 procedures without. No differences in group characteristics were observed except for gender. Fourteen patients (13.1%) had a leakage. The incidence and severity of leakage were not different between the patients with and without a drain. There was no significant difference in time to diagnosis (1 vs. 0 days; p 0.34), mortality rate (7.5 vs. 2.5%; p 0.41), and median length of hospital stay (9 days in both groups; p 0.46). Daily amylase measurement in drain fluid does not influence the early recognition and management of leakage in gastric cancer surgery.

  13. Current practice patterns of drain usage amongst UK and Irish surgeons performing bilateral breast reductions: Evidence down the drain.

    PubMed

    Sugrue, Conor M; McInerney, Niall; Joyce, Cormac W; Jones, Deidre; Hussey, Alan J; Kelly, Jack L; Kerin, Michael J; Regan, Padraic J

    2015-01-01

    Bilateral breast reduction (BBR) is one of the most frequently performed female breast operations. Despite no evidence supporting efficacy of drain usage in BBRs, postoperative insertion is common. Recent high quality evidence demonstrating potential harm from drain use has subsequently challenged this traditional practice. The aim of this study is to assess the current practice patterns of drains usage by Plastic & Reconstructive and Breast Surgeons in UK and Ireland performing BBRs. An 18 question survey was created evaluating various aspects of BBR practice. UK and Irish Plastic & Reconstructive and Breast Surgeons were invited to participate by an email containing a link to a web-based survey. Statistical analysis was performed with student t-test and chi-square test. Two hundred and eleven responding surgeons were analysed, including 80.1% (171/211) Plastic Surgeons and 18.9% (40/211) Breast Surgeons. Of the responding surgeons, 71.6% (151/211) routinely inserted postoperative drains, for a mean of 1.32 days. Drains were used significantly less by surgeons performing ≥20 BBRs (p = 0.02). With the majority of BBRs performed as an inpatient procedure, there was a trend towards less drain usage in surgeons performing this procedure as an outpatient; however, this was not statistically significant (p = 0.07). Even with the high level of evidence demonstrating the safety of BBR without drains, they are still routinely utilised. In an era of evidence- based medicine, surgeons performing breast reductions must adopt the results from scientific research into their clinical practice.

  14. Multiple variations of the renal and testicular vessels: possible embryological basis and clinical importance.

    PubMed

    Mazengenya, Pedzisai

    2016-08-01

    During routine dissection of the abdominal cavity of a 55-year-old African male cadaver, multiple anomalies including renal and testicular vessels were encountered. The right kidney was supplied by three right hilar renal arteries arising from the abdominal aorta at different vertebral levels whereas only one left renal artery supplied the left kidney. On the right three renal veins drained the kidney into the inferior vena cava. In contrast, the left kidney was drained by a single renal vein which received a large primary posterior tributary. The primary posterior tributary had three tributaries from the posterior lumbar region. The right testis had two sources of arterial supply; one from the subcostal artery and another from the abdominal aorta. The left testis was supplied normally by a single testicular artery. The right testis was drained by four testicular veins as follows: one drained into the subcostal vein, the other two drained separately for a longer course and joined shortly before draining into the right main renal vein, the fourth one drained into the anterior aspect of the inferior vena cava at the level of the second lumbar vertebra. On the left, the testicle was drained by two testicular veins which travelled separately from the deep inguinal ring and joined shortly before they drain into the left renal vein. This variation may represent an immature form of complicated development of kidneys and testes. Additionally, emphasis must be put on preoperative vascular examination to avoid surgical complications from variant vessels in this region.

  15. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    PubMed Central

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001), but the trend of pain score between groups was not significantly different (P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group (P < 0.05). Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF. PMID:29387121

  16. Impact of Drain Insertion After Perforated Peptic Ulcer Repair in a Japanese Nationwide Database Analysis.

    PubMed

    Okumura, K; Hida, K; Kunisawa, S; Nishigori, T; Hosogi, H; Sakai, Y; Imanaka, Y

    2018-03-01

    Many perforated peptic ulcers (PPUs) require surgical repair due to diffuse peritonitis. However, few studies have examined the clinical effects of postoperative drainage after PPU repair. This study aimed to investigate the drain insertion rates in patients who underwent PPU repair in Japan, and to clarify the impact of drain insertion on the postoperative clinical course. A retrospective nationwide cohort study was performed using administrative claims data of patients who had undergone PPU repair between 2010 and 2016. These patients were divided into two groups based on whether or not they had received a postoperative abdominal drain. Using propensity score matching, we compared the incidences of postoperative interventions for abdominal complications between both groups. A total of 4869 patients from 324 hospitals were analyzed. At the hospital level, drains were placed in all PPU repair patients in 229 (70.7%) hospitals. At the patient level, 4401 patients (90.4%) had drains inserted. The drain group was associated with a higher emergency admission rate, poorer preoperative shock status, longer anesthetic time, and a higher amount of intra-abdominal irrigation. In the propensity score-matched patients, the drain group had a significantly lower incidence of postoperative interventions than the no-drain group (1.9 vs. 5.6%; risk ratio = 0.35; 95% confidence interval 0.16-0.73; P = 0.003). Postoperative drainage was performed in the majority of patients who underwent PPU repair in Japan. Drainage following PPU repair may facilitate patient recovery by reducing the need for postoperative interventions.

  17. Using Smoke Injection in Drains to Identify Potential Preferential Pathways in a Drained Arable Field

    NASA Astrophysics Data System (ADS)

    Nielsen, M. H.; Petersen, C. T.; Hansen, S.

    2014-12-01

    Macropores forming a continuous pathway between the soil surface and subsurface drains favour the transport of many contaminants from agricultural fields to surface waters. The smoke injection method presented by Shipitalo and Gibbs (2000) used for demonstrating and quantifying such pathways has been further developed and used on a drained Danish sandy loam. In order to identify the preferential pathways to drains, smoke was injected in three 1.15 m deep tile drains (total drain length 93 m), and smoke emitting macropores (SEMP) at the soil surface were counted and characterized as producing either strong or weak plumes compared to reference plumes from 3 and 6 mm wide tubes. In the two situations investigated in the present study - an early spring and an autumn situation, smoke only penetrated the soil surface layer via earthworm burrows located in a 1.0 m wide belt directly above the drain lines. However, it is known from previous studies that desiccation fractures in a dry summer situation also can contribute to the smoke pattern. The distance between SEMP measured along the drain lines was on average 0.46 m whereas the average spacing between SEMP with strong plumes was 2.3 m. Ponded water was applied in 6 cm wide rings placed above 52 burrows including 17 reference burrows which did not emit smoke. Thirteen pathways in the soil were examined using dye tracer and profile excavation. SEMP with strong plumes marked the entrance of highly efficient transport pathways conducting surface applied water and dye tracer into the drain. However, no single burrow was traced all the way from the surface into the drain, the dye patterns branched off in a network of other macropores. Water infiltration rates were significantly higher (P < 0.05) in SEMP with strong plumes (average rate: 247 mL min-1 n = 19) compared to SEMP with weak plumes (average rate: 87 mL min-1 n = 16) and no plumes (average rate: 56 mL min-1 n = 17). The results suggest that the smoke injection method is useful for identification of potentially efficient pathways for surface applied contaminants to drains and surface waters, pathways being associated primarily with unevenly distributed SEMP producing strong smoke plumes.

  18. A theoretical approach to study the optical sensitivity of a MESFET

    NASA Astrophysics Data System (ADS)

    Dutta, Sutanu

    2018-05-01

    A theoretical model to study the optical sensitivity of a metal-semiconductor field effect transistor has been proposed for a relatively high drain field. An analytical expression of drain current of the device has been derived for a MESFET under optical illumination considering field dependent mobility of electrons across the channel. The variation of drain current with and without optical illumination has been studied with drain and gate voltages. The optical sensitivity of the drain current has been studied for different biasing conditions and gate lengths. In addition, the shift in threshold voltage of a MESFET under optical illumination is determined and optical sensitivity of the device in terms of its threshold voltage has been studied.

  19. Enhancement of capacitance benefit by drain offset structure in tunnel field-effect transistor circuit speed associated with tunneling probability increase

    NASA Astrophysics Data System (ADS)

    Asai, Hidehiro; Mori, Takahiro; Matsukawa, Takashi; Hattori, Junichi; Endo, Kazuhiko; Fukuda, Koichi

    2018-04-01

    The effect of a drain offset structure on the operation speed of a tunnel field-effect transistor (TFET) ring oscillator is investigated by technology computer-aided design (TCAD) simulation. We demonstrate that the reduction of gate-drain capacitance by the drain offset structure dramatically increases the operation speed of the ring oscillators. Interestingly, we find that this capacitance benefit to operation speed is enhanced by the increase in band-to-band tunneling probability. The “synergistic” speed enhancement by the drain offset structure and the tunneling rate increase will have promising application to the significant improvement of the operation speed of TFET circuits.

  20. Homogenization of one-dimensional draining through heterogeneous porous media including higher-order approximations

    NASA Astrophysics Data System (ADS)

    Anderson, Daniel M.; McLaughlin, Richard M.; Miller, Cass T.

    2018-02-01

    We examine a mathematical model of one-dimensional draining of a fluid through a periodically-layered porous medium. A porous medium, initially saturated with a fluid of a high density is assumed to drain out the bottom of the porous medium with a second lighter fluid replacing the draining fluid. We assume that the draining layer is sufficiently dense that the dynamics of the lighter fluid can be neglected with respect to the dynamics of the heavier draining fluid and that the height of the draining fluid, represented as a free boundary in the model, evolves in time. In this context, we neglect interfacial tension effects at the boundary between the two fluids. We show that this problem admits an exact solution. Our primary objective is to develop a homogenization theory in which we find not only leading-order, or effective, trends but also capture higher-order corrections to these effective draining rates. The approximate solution obtained by this homogenization theory is compared to the exact solution for two cases: (1) the permeability of the porous medium varies smoothly but rapidly and (2) the permeability varies as a piecewise constant function representing discrete layers of alternating high/low permeability. In both cases we are able to show that the corrections in the homogenization theory accurately predict the position of the free boundary moving through the porous medium.

  1. Effects of pond draining on biodiversity and water quality of farm ponds.

    PubMed

    Usio, Nisikawa; Imada, Miho; Nakagawa, Megumi; Akasaka, Munemitsu; Takamura, Noriko

    2013-12-01

    Farm ponds have high conservation value because they contribute significantly to regional biodiversity and ecosystem services. In Japan pond draining is a traditional management method that is widely believed to improve water quality and eradicate invasive fish. In addition, fishing by means of pond draining has significant cultural value for local people, serving as a social event. However, there is a widespread belief that pond draining reduces freshwater biodiversity through the extirpation of aquatic animals, but scientific evaluation of the effectiveness of pond draining is lacking. We conducted a large-scale field study to evaluate the effects of pond draining on invasive animal control, water quality, and aquatic biodiversity relative to different pond-management practices, pond physicochemistry, and surrounding land use. The results of boosted regression-tree models and analyses of similarity showed that pond draining had little effect on invasive fish control, water quality, or aquatic biodiversity. Draining even facilitated the colonization of farm ponds by invasive red swamp crayfish (Procambarus clarkii), which in turn may have detrimental effects on the biodiversity and water quality of farm ponds. Our results highlight the need for reconsidering current pond management and developing management plans with respect to multifunctionality of such ponds. Efectos del Drenado de Estanques sobre la Biodiversidad y la Calidad del Agua en Estanques de Cultivo. © 2013 Society for Conservation Biology.

  2. Drain Current Modulation of a Single Drain MOSFET by Lorentz Force for Magnetic Sensing Application.

    PubMed

    Chatterjee, Prasenjit; Chow, Hwang-Cherng; Feng, Wu-Shiung

    2016-08-30

    This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in size with respect to the metal loop, which ensures that the generated magnetic field is approximately uniform. The change of drain current and change of bulk current per micron device width has been measured. The result shows that the difference drain current is about 145 µA for the maximum applied magnetic field. Such changes occur from the applied Lorentz force to push out the carriers from the channel. Based on the drain current difference, the change in effective mobility has been detected up to 4.227%. Furthermore, a detailed investigation reveals that the device behavior is quite different in subthreshold and saturation region. A change of 50.24 µA bulk current has also been measured. Finally, the device has been verified for use as a magnetic sensor with sensitivity 4.084% (29.6 T(-1)), which is very effective as compared to other previously reported works for a single device.

  3. Mechanisms of surface runoff genesis on a subsurface drained soil affected by surface crusting: A field investigation

    NASA Astrophysics Data System (ADS)

    Augeard, Bénédicte; Kao, Cyril; Chaumont, Cédric; Vauclin, Michel

    Artificial drainage has been subject to widespread criticism because of its impact on water quality and because there is suspicion that it may have detrimental effects on flood genesis. The present work aims at a better understanding of the mechanisms controlling infiltration and surface runoff genesis, particularly in soils with artificial drainage and affected by surface crusting. A field experiment was conducted during one drainage season (November 2003-March 2004) in the Brie region (80 km east of Paris, France) on a subsurface drained silty soil. Water table elevation and surface runoff were monitored above the drain and at midpoint between drains. Soil water pressure head was measured at various depths and locations between the midpoint and the drain. Soil surface characteristics (microtopography and degree of structural and sedimentary crust development) were recorded regularly on the experimental site and on other plots of various drainage intensities. The results show that the first surface runoff events were induced by high water table. However, runoff was higher at midpoint between the drains because water table reached the soil surface at that point, thus considerably reducing infiltration capacity compared to that above the drain. Comparing different plots, the area with older drainage installation (1948) yielded the most surface runoff. Wider drain spacing, smaller drain depth and possible plugging may have led to a greater area of saturated soil between drains. During the winter period, the impact of raindrops induced the formation of a structural crust on the soil surface. Furthermore, the development of the sedimentary crust, which was favored by water actually flowing on the soil surface during the high water table periods could be correlated with surface runoff volume. The formation of this crust had a significant impact on runoff occurrence at the end of the winter. Therefore, poorly drained fields presented more favorable conditions for both Horton type runoff and saturation excess runoff. Drainage effectively reduces surface runoff occurrences not only by lowering the water table in winter but also by limiting soil surface sealing.

  4. Experimental utilization of tire shreds to enhance highway drainage.

    DOT National Transportation Integrated Search

    2001-03-01

    This project investigates the practical benefits of using shredded tires as a free draining material : in a subsurface French drain to enhance drainage along a section of highway. French drains are : below-grade structures designed to re-direct groun...

  5. Reduction in wick drain effectiveness with spacing for Utah silts and clays.

    DOT National Transportation Integrated Search

    2012-04-01

    Although decreasing the spacing of vertical drains usually decreases the time for consolidation, previous field tests have shown that there is a critical drain spacing for which tighter spacing does not decrease the time for consolidation. This...

  6. Generation of airborne listeria from floor drain

    USDA-ARS?s Scientific Manuscript database

    Listeria monocytogenes can colonize in floor drains in poultry processing plants and further throughout processing facilities, remaining present even after cleaning and disinfection of the plant. Therefore, during wash down, workers exercise caution to prevent escape and transfer of drain microflor...

  7. Efficacy of tranexamic acid plus drain-clamping to reduce blood loss in total knee arthroplasty: A meta-analysis.

    PubMed

    Zhang, Yan; Zhang, Jun-Wei; Wang, Bao-Hua

    2017-06-01

    Perioperative blood loss is still an unsolved problem in total knee arthroplasty (TKA). The efficacy of the preoperative use of tranexamic acid (TXA) plus drain-clamping to reduce blood loss in TKA has been debated. This meta-analysis aimed to illustrate the efficacy of TXA plus drain-clamping to reduce blood loss in patients who underwent a TKA. In February 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, the Cochrane Database of Systematic Reviews, and Google Scholar. Data from patients prepared for TKA in studies that compared TXA plus drain-clamping versus TXA alone, drain-clamping alone, or controls were retrieved. The primary endpoint was the need for transfusion. The secondary outcomes were total blood loss, blood loss in drainage, the decrease in hemoglobin, and the occurrence of deep venous thrombosis. After testing for publication bias and heterogeneity between studies, data were aggregated for random-effects models when necessary. Ultimately, 5 clinical studies with 618 patients (TXA plus drain-clamping group = 249, control group = 130, TXA-alone group = 60, and drain-clamping group = 179) were included. TXA plus drain-clamping could decrease the need for transfusion, total blood loss, blood loss in drainage, and the decrease in hemoglobin than could the control group, the TXA-alone group, and the drain-clamping group (P < .05). There was no significant difference between the occurrence of deep venous thrombosis between the included groups (P > .05). TXA plus drain-clamping can achieve the maximum effects of hemostasis in patients prepared for primary TKA. Because the number and the quality of the included studies were limited, more high-quality randomized controlled trials are needed to identify the optimal dose of TXA and the clamping hours in patients prepared for TKA.

  8. Nitrate and phosphorus transport through subsurface drains under free and controlled drainage.

    PubMed

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-05-28

    Controlled drainage (CD) is a structural conservation practice in which the drainage outlet is managed in order to reduce drain flow volume and nutrient loads to water bodies. The goal of this study was to evaluate the potential of CD to improve water quality for two different seasons and levels of outlet control, using ten years of data collected from an agricultural drained field in eastern Indiana with two sets of paired plots. The Rank Sum test was used to quantify the impact of CD on cumulative annual drain flow and nitrate-N and phosphorus loads. CD plots had a statistically significant (at 5% level) lower annual drain flow (eastern pair: 39%; western pair: 25%) and nitrate load (eastern pair: 43%; western pair: 26%) compared to free draining (FD) plots, while annual soluble reactive phosphorus (SRP) and total phosphorus (TP) loads were not significantly different. An ANCOVA model was used to evaluate the impact of CD on daily drain flow, nitrate-N, SRP and TP concentrations and loads during the two different periods of control. The average percent reduction of daily drain flow was 68% in the eastern pair and 58% in the western pair during controlled drainage at the higher outlet level (winter) and 64% and 58% at the lower outlet level (summer) in the eastern and western pairs, respectively. Nitrate load reduction was similar to drain flow reduction, while the effect of CD on SRP and TP loads was not significant except for the increase in SRP in one pair. These results from a decade-long field monitoring and two different statistical methods enhance our knowledge about water quality impacts of CD system and support this management practice as a reliable system for reducing nitrate loss through subsurface drains, mainly caused by flow reduction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Efficacy of tranexamic acid plus drain-clamping to reduce blood loss in total knee arthroplasty

    PubMed Central

    Zhang, Yan; Zhang, Jun-Wei; Wang, Bao-Hua

    2017-01-01

    Abstract Background: Perioperative blood loss is still an unsolved problem in total knee arthroplasty (TKA). The efficacy of the preoperative use of tranexamic acid (TXA) plus drain-clamping to reduce blood loss in TKA has been debated. This meta-analysis aimed to illustrate the efficacy of TXA plus drain-clamping to reduce blood loss in patients who underwent a TKA. Methods: In February 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, the Cochrane Database of Systematic Reviews, and Google Scholar. Data from patients prepared for TKA in studies that compared TXA plus drain-clamping versus TXA alone, drain-clamping alone, or controls were retrieved. The primary endpoint was the need for transfusion. The secondary outcomes were total blood loss, blood loss in drainage, the decrease in hemoglobin, and the occurrence of deep venous thrombosis. After testing for publication bias and heterogeneity between studies, data were aggregated for random-effects models when necessary. Results: Ultimately, 5 clinical studies with 618 patients (TXA plus drain-clamping group = 249, control group = 130, TXA-alone group = 60, and drain-clamping group = 179) were included. TXA plus drain-clamping could decrease the need for transfusion, total blood loss, blood loss in drainage, and the decrease in hemoglobin than could the control group, the TXA-alone group, and the drain-clamping group (P < .05). There was no significant difference between the occurrence of deep venous thrombosis between the included groups (P > .05). Conclusions: TXA plus drain-clamping can achieve the maximum effects of hemostasis in patients prepared for primary TKA. Because the number and the quality of the included studies were limited, more high-quality randomized controlled trials are needed to identify the optimal dose of TXA and the clamping hours in patients prepared for TKA. PMID:28658157

  10. Drain placement can safely be omitted for open partial nephrectomy: Results from a prospective randomized trial.

    PubMed

    Kriegmair, Maximilian C; Mandel, Philipp; Krombach, Patrick; Dönmez, Hasan; John, Axel; Häcker, Axel; Michel, Maurice S

    2016-05-01

    To examine the benefit of drain placement during open partial nephrectomy. Overall, 106 patients treated with open partial nephrectomy were enrolled in a prospective randomized trial. Based on the randomization, a drain was placed or omitted. Complications were assessed according to the Clavien classification. Pain level and requirement for analgesics was evaluated according to a customized pattern. There was no significant difference in the two groups regarding age, body mass index, American Society of Anesthesiologists score, tumor size and nephrometry (preoperative aspects and dimensions used for an anatomical classification). In terms of overall and drain-related complications, no advantage of placing a drain could be proven (P = 0.249). Patients with a drain suffered from a significantly higher pain level (P = 0.01) and showed prolonged mobilization (P < 0.001). There was no difference in bowel movements and requirement of additional analgesics (P = 0.347 and 0.11). The results of the study suggest that drain placement during open partial nephrectomy can safely be omitted, even in cases with violation of the collecting system. © 2016 The Japanese Urological Association.

  11. Minimally invasive retrieval of a retained Jackson--Pratt drainage tube using the Sachse urethrotome.

    PubMed

    Fariña-Perez, Luis Angel; Pesqueira-Santiago, Daniel

    2012-05-01

    A retained postoperative drain tube, trapped by one or more of the sutures of the abdominal wall closure, is a rare complication of frustrating consequences and potential legal repercussions. There are few reports of techniques for minimally invasive removal of an anchored postoperative drain tube, which not infrequently has been treated by reopening the wound. A 75 years-old man with a left T2-T3N0M0 renal carcinoma was treated with transperitoneal laparoscopic nephrectomy and a Jackson-Pratt drain was left in place. Drain removal the day after revealed impossible, as if being caught with fascial suture. With the patient under sedation, we introduced a Sachse urethrotome parallel to the drain, and the abdominal fascia was identified, then the polyglycolic stitch anchoring it to the wall could be severed, freeing the drain. Percutaneous extraction with the Sachse urethrotome of an anchored postoperative drain, should be the first option, before trying a forced traction or using more complex options. This technique is for the first time published in the Spanish bibliography, and we think this possibility should be disclosed to abdominal surgeons.

  12. A novel gate and drain engineered charge plasma tunnel field-effect transistor for low sub-threshold swing and ambipolar nature

    NASA Astrophysics Data System (ADS)

    Yadav, Dharmendra Singh; Raad, Bhagwan Ram; Sharma, Dheeraj

    2016-12-01

    In this paper, we focus on the improvement of figures of merit for charge plasma based tunnel field-effect transistor (TFET) in terms of ON-state current, threshold voltage, sub-threshold swing, ambipolar nature, and gate to drain capacitance which provides better channel controlling of the device with improved high frequency response at ultra-low supply voltages. Regarding this, we simultaneously employ work function engineering on the drain and gate electrode of the charge plasma TFET. The use of gate work function engineering modulates the barrier on the source/channel interface leads to improvement in the ON-state current, threshold voltage, and sub-threshold swing. Apart from this, for the first time use of work function engineering on the drain electrode increases the tunneling barrier for the flow of holes on the drain/channel interface, it results into suppression of ambipolar behavior. The lowering of gate to drain capacitance therefore enhanced high frequency parameters. Whereas, the presence of dual work functionality at the gate electrode and over the drain region improves the overall performance of the charge plasma based TFET.

  13. 33 CFR 149.145 - What are the requirements for curbs, gutters, drains, and reservoirs?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION..., drains, and reservoirs? Each pumping platform complex must have enough curbs, gutters, drains, and... ocean according to the port's National Pollution Discharge Elimination System permit. ...

  14. 33 CFR 149.145 - What are the requirements for curbs, gutters, drains, and reservoirs?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION..., drains, and reservoirs? Each pumping platform complex must have enough curbs, gutters, drains, and... ocean according to the port's National Pollution Discharge Elimination System permit. ...

  15. Evaluation of trench and slotted drain maintenance and cleaning : Phase 1 : final report.

    DOT National Transportation Integrated Search

    2017-03-01

    Trench and slotted drains are increasingly being used by ODOT to remove storm water from the roadways. These drains have to be properly cleaned and maintained to prevent vehicles from hydroplaning, eliminate flooding and avoid premature roadway failu...

  16. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study

    PubMed Central

    Bhate, Kalyani; Dolas, RS; Kumar, SN Santhosh; Waknis, Pushkar

    2016-01-01

    Introduction Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. Aim To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Materials and Methods Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. Results The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. Conclusion The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus. PMID:28209003

  17. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology.

    PubMed

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-10-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3(+) CD4(+) CD8(-) , CD3(+) CD4(-) CD8(+) and human leucocyte antigen D-related (HLA-DR)(+) CD19(+) lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1-2 post-Itx, analysis by short tandem repeats fingerprinting of CD3(+) CD8(+) sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. © 2010 The Authors. Clinical and Experimental Immunology © 2010 British Society for Immunology.

  18. Analysis of immune cells draining from the abdominal cavity as a novel tool to study intestinal transplant immunobiology

    PubMed Central

    Meier, D; Cagnola, H; Ramisch, D; Rumbo, C; Chirdo, F; Docena, G; Gondolesi, G E; Rumbo, M

    2010-01-01

    During intestinal transplant (ITx) operation, intestinal lymphatics are not reconstituted. Consequently, trafficking immune cells drain freely into the abdominal cavity. Our aim was to evaluate whether leucocytes migrating from a transplanted intestine could be recovered from the abdominal draining fluid collected by a peritoneal drainage system in the early post-ITx period, and to determine potential applications of the assessment of draining cellular populations. The cell composition of the abdominal draining fluid was analysed during the first 11 post-ITx days. Using flow cytometry, immune cells from blood and draining fluid samples obtained the same day showed an almost complete lymphopenia in peripheral blood, whereas CD3+CD4+CD8-, CD3+CD4-CD8+ and human leucocyte antigen D-related (HLA-DR)+CD19+ lymphocytes were the main populations in the draining fluid. Non-complicated recipients evolved from a mixed leucocyte pattern including granulocytes, monocytes and lymphocytes to an exclusively lymphocytic pattern along the first post-ITx week. At days 1–2 post-Itx, analysis by short tandem repeats fingerprinting of CD3+CD8+ sorted T cells from draining fluid indicated that 50% of cells were from graft origin, whereas by day 11 post-ITx this proportion decreased to fewer than 1%. Our results show for the first time that the abdominal drainage fluid contains mainly immune cells trafficking from the implanted intestine, providing the opportunity to sample lymphocytes draining from the grafted organ along the post-ITx period. Therefore, this analysis may provide information useful for understanding ITx immunobiology and eventually could also be of interest for clinical management. PMID:20831713

  19. Concentrations and loads of suspended sediment and nutrients in surface water of the Yakima River basin, Washington, 1999-2000 [electronic resource] : with an analysis of trends in concentrations

    USGS Publications Warehouse

    Ebbert, James C.; Embrey, Sandra S.; Kelley, Janet A.

    2003-01-01

    Spatial and temporal variations in concentrations and loads of suspended sediment and nutrients in surface water of the Yakima River Basin were assessed using data collected during 1999?2000 as part of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program. Samples were collected at 34 sites located throughout the Basin in August 1999 using a Lagrangian sampling design, and also were collected weekly and monthly from May 1999 through January 2000 at three of the sites. Nutrient and sediment data collected at various time intervals from 1973 through 2001 by the USGS, Bureau of Reclamation, Washington State Department of Ecology, and Roza-Sunnyside Board of Joint Control were used to assess trends in concentrations. During irrigation season (mid-March to mid-October), concentrations of suspended sediment and nutrients in the Yakima River increase as relatively pristine water from the forested headwaters moves downstream and mixes with discharges from streams, agricultural drains, and wastewater treatment plants. Concentrations of nutrients also depend partly on the proportions of mixing between river water and discharges: in years of ample water supply in headwater reservoirs, more water is released during irrigation season and there is more dilution of nutrients discharged to the river downstream. For example, streamflow from river mile (RM) 103.7 to RM 72 in August 1999 exceeded streamflow in July 1988 by a factor of almost 2.5, but loads of total nitrogen and phosphorus discharged to the reach from streams, drains, and wastewater treatment plants were only 1.2 and 1.1 times larger. In years of ample water supply, canal water, which is diverted from either the Yakima or Naches River, makes up more of the flow in drains and streams carrying agricultural return flows. The canal water dilutes nutrients (especially nitrate) transported to the drains and streams in runoff from fields and in discharges from subsurface field drains and the shallow ground-water system. The average concentration of total nitrogen in drains and streams discharging to the Yakima River from RM 103.7 to RM 72 in August 1999 was 2.63 mg/L, and in July 1988 was 3.16 mg/L; average concentrations of total phosphorus were 0.20 and 0.26 mg/L. After irrigation season, streamflow in agricultural drains decreases because irrigation water is no longer diverted from the Yakima and Naches Rivers. As a result, concentrations of total nitrogen in drains increase because nitrate, which constitutes much of total nitrogen, continues to enter the drains from subsurface drains and shallow ground water. Concentrations of total phosphorus and suspended sediment often decrease, because they are transported to the drains in runoff of irrigation water from fields. In Granger Drain, concentrations of total nitrogen ranged from 2-4 mg/L during irrigation season and increased to about 6 mg/L after irrigation season, and concentrations of total phosphorus, as high as 1 mg/L, decreased to about 0.2 mg/L. In calendar year 1999, Moxee Drain transported an average of 28,000 lb/d (pounds per day) of suspended sediment, 380 lb/d of total nitrogen, and 46 lb/d of total phosphorus to the Yakima River. These loads were about half the average loads transported by Granger Drain during the same period. Average streamflows were similar for the two drains, so the difference in loads was due to differences in constituent concentrations: those in Moxee Drain were about 40-60 percent less than those in Granger Drain. Loads of suspended sediment and total phosphorus in Moxee and Granger Drains were nearly four times higher during irrigation season than during the non-irrigation season because with increased flow during irrigation season, concentrations of suspended sediment and total phosphorus are usually higher. Loads of nitrate in the drains were about the same in both seasons because nitrate concentrations are higher during the non-irrigation season.

  20. Towards evidence-based emergency medicine: best BETs from the Manchester Royal Infirmary. BET 4: does size matter? Chest drains in haemothorax following trauma.

    PubMed

    2013-11-01

    A short-cut review was carried out to establish whether the size of chest drain inserted is important in haemothoraces. Forty-nine papers were found of which four presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of these best papers are shown in table 4. The clinical bottom line is that while the available evidence suggests that small bore drains may be as effective as large bore drains in resolving traumatic haemothoraces without additional complications, there is insufficient evidence currently available to recommend a change to standard practice (ie, large bore drains).

  1. Effects of drain bias on the statistical variation of double-gate tunnel field-effect transistors

    NASA Astrophysics Data System (ADS)

    Choi, Woo Young

    2017-04-01

    The effects of drain bias on the statistical variation of double-gate (DG) tunnel field-effect transistors (TFETs) are discussed in comparison with DG metal-oxide-semiconductor FETs (MOSFETs). Statistical variation corresponds to the variation of threshold voltage (V th), subthreshold swing (SS), and drain-induced barrier thinning (DIBT). The unique statistical variation characteristics of DG TFETs and DG MOSFETs with the variation of drain bias are analyzed by using full three-dimensional technology computer-aided design (TCAD) simulation in terms of the three dominant variation sources: line-edge roughness (LER), random dopant fluctuation (RDF) and workfunction variation (WFV). It is observed than DG TFETs suffer from less severe statistical variation as drain voltage increases unlike DG MOSFETs.

  2. 76 FR 76060 - Final Flood Elevation Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... Port Georgetown. Sheldon Street. At the confluence with +646 Knight Intercounty Drain. Bliss Creek.... Georgetown. At the downstream side of +616 Kenowa Avenue Southwest. Knight Intercounty Drain At the... River/Black Creek of Zeeland Approximately 0.8 mile +584 Charter Township of Drain. upstream of River...

  3. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  4. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  5. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil system drains. 121.241 Section 121.241..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.241 Oil system drains... position, must be provided to allow safe drainage of the entire oil system. ...

  6. Charge-Dissipative Electrical Cables

    NASA Technical Reports Server (NTRS)

    Kolasinski, John R.; Wollack, Edward J.

    2004-01-01

    Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

  7. Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty.

    PubMed

    Srinivasan, Sathish; Rootman, David S

    2007-09-01

    To describe a new slit-lamp technique for draining interface fluid to manage complete donor disc detachments following Descemet's stripping (automated) endothelial keratoplasty (DSEK/DSAEK). Interventional case series. Five DSEK/DSAEK patients presented on the first postoperative day with complete detachment of the donor lenticule. Slit-lamp biomicroscopy showed interface fluid preventing attachment of the donor disc to the host stromal bed. A new slit-lamp technique is described to drain the interface fluid. This technique involved completely filling the anterior chamber with an air bubble using a 30-gauge needle on a 3 ml syringe. Following this, a 0.12 forceps was used to open the inferior mid-peripheral corneal drainage slit to drain the interface fluid. This technique was successful in draining the interface fluid in all five patients, leading to immediate complete reattachment of the donor disc. Donor disc detachments following DSEK/DSAEK can be successfully managed by this slit-lamp technique of draining the interface fluid.

  8. Pupal productivity & nutrient reserves of Aedes mosquitoes breeding in sewage drains & other habitats of Kolkata, India: Implications for habitat expansion & vector management.

    PubMed

    Banerjee, Soumyajit; Mohan, Sushree; Saha, Nabaneeta; Mohanty, Siba Prasad; Saha, Goutam K; Aditya, Gautam

    2015-12-01

    The quality of breeding sites is reflected through the pupal productivity and the life history traits of Aedes mosquitoes. Using nutrient reserves and pupal productivity of Aedes as indicators, the larval habitats including sewage drains were characterized to highlight the habitat expansion and vector management. The pupae and adults collected from the containers and sewage drains were characterized in terms of biomass and nutrient reserves and the data were subjected to three way factorial ANOVA. Discriminant function analyses were performed to highlight the differences among the habitats for sustenance of Aedes mosquitoes. Survey of larval habitats from the study area revealed significant differences (P<0.05) in the pupal productivity of Aedes among the habitats and months. Despite sewage drains being comparatively less utilized for breeding, the pupae were of higher biomass with corresponding adults having longer wings in contrast to other habitats. The nutrient reserve of the adults emerging from pupae of sewage drains was significantly higher (P<0.05), compared to other habitats, as reflected through the discriminant function analysis. The present results showed that for both Ae. aegypti and Ae. albopictus, sewage drains were equally congenial habitat as were plastic, porcelain and earthen habitats. Availability of Aedes immature in sewage drains poses increased risk of dengue, and thus vector control programme should consider inclusion of sewage drains as breeding habitat of dengue vector mosquitoes.

  9. Jet-controlled freeze valve for use in a glass melter

    DOEpatents

    Routt, Kenneth R.

    1986-09-02

    A drain valve for use in a furnace for the melting of thermoplastic material. The furnace includes a drain cavity formed in its bottom for withdrawing a flow of thermoplastic material. The drain valve includes a flow member which include a flow tube having an inlet and outlet for the material, and coaxially disposed concentric tubular members defining annuli surrounding the flow tube. The tubular members include heating and cooling means for the flow tube. The flow member is adapted to fit in mating relationship in the drain cavity. A freeze valve member is disposed adjacent the outlet of the flow member. The freeze valve member includes heating means and has a plurality of air jets adapted to direct streams of pressurized air at the outlet to control the flow of thermoplastic material through the flow members. The drain valve can also be used in a furnace of glass melting that includes a drain cavity for withdrawing molten glass from the furnace. The drain valve includes a flow tube member having an inlet and outlet, and having heating and cooling means. The tube member is adapted to fit in mating relationship with the drain cavity. A freeze valve member is disposed at the outlet of the flow tube member. The freeze valve member includes heating means and has a plurality of air jets adapted to direct a stream of pressurized air at the outlet to control the flow of glass through the flow tube member.

  10. Comparison of natural drainage group and negative drainage groups after total thyroidectomy: prospective randomized controlled study.

    PubMed

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum; Son, Young-Ik

    2013-01-01

    The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. The amount of drainage during the first 24 hours postoperatively was 41.68 ± 3.93 mL in the negative drain group and 25.3 ± 2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19 ± 4.26 mL and natural drain groups 21.53 ± 2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done.

  11. Jet-controlled freeze valve for use in a glass melter

    DOEpatents

    Routt, Kenneth R.

    1986-01-01

    A drain valve for use in a furnace for the melting of thermoplastic material. The furnace includes a drain cavity formed in its bottom for withdrawing a flow of thermoplastic material. The drain valve includes a flow member which include a flow tube having an inlet and outlet for the material, and coaxially disposed concentric tubular members defining annuli surrounding the flow tube. The tubular members include heating and cooling means for the flow tube. The flow member is adapted to fit in mating relationship in the drain cavity. A freeze valve member is disposed adjacent the outlet of the flow member. The freeze valve member includes heating means and has a plurality of air jets adapted to direct streams of pressurized air at the outlet to control the flow of thermoplastic material through the flow members. The drain valve can also be used in a furnace of glass melting that includes a drain cavity for withdrawing molten glass from the furnace. The drain valve includes a flow tube member having an inlet and outlet, and having heating and cooling means. The tube member is adapted to fit in mating relationship with the drain cavity. A freeze valve member is disposed at the outlet of the flow tube member. The freeze valve member includes heating means and has a plurality of air jets adapted to direct a stream of pressurized air at the outlet to control the flow of glass through the flow tube member.

  12. Evaluation of the Environmental Fate of Munition Compounds in Soil.

    DTIC Science & Technology

    1979-06-01

    temperature in- duction furnace. Nitrate Water samples were analyzed for nitrate (NO:T) by a Dion -X System Ten ion chromatograph. Nitrite Water samples...moderately well drained Celins , somewhat poorly drained Crosby and Conover, and very poorly drained Kokomo form a drainage sequence with the

  13. The Draining Cylinder

    ERIC Educational Resources Information Center

    James Graham-Eagle

    2009-01-01

    This article explores the time it takes for a liquid to drain from a cylindrical container through a hole in the bottom. Using dimensional analysis and some thought experiments this time is determined and Torricelli's law derived as a consequence. Finally, the effect of pouring liquid into the container as it drains is considered.

  14. Toxic-Waste Disposal by Drain-in-Furnace Technique

    NASA Technical Reports Server (NTRS)

    Compton, L. E.; Stephens, J. B.; Moynihan, P. I.; Houseman, J.; Kalvinskas, J. J.

    1986-01-01

    Compact furnace moved from site to site. Toxic industrial waste destroyed using furnace concept developed for disposal of toxic munitions. Toxic waste drained into furnace where incinerated immediately. In furnace toxic agent rapidly drained and destroyed in small combustion chamber between upper and lower layers of hot ceramic balls

  15. 75 FR 61999 - Airworthiness Directives; The Boeing Company Model 767 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-07

    ..., for certain airplanes, reworking the bonding jumper assemblies on the drain tube assemblies of the... inspections of the drain tube assemblies of the slat track housing of the wings to find discrepancies... would also require replacing the drain tube assemblies. For certain airplanes, this proposed AD would...

  16. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil system drains. 27.1021 Section 27.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  17. 14 CFR 27.1021 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Oil system drains. 27.1021 Section 27.1021 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS...) must be provided to allow safe drainage of the oil system. Each drain must— (a) Be accessible; and (b...

  18. Treatment of phosphorus transported from tile and ditch-drained agricultural fields using sorption materials

    USDA-ARS?s Scientific Manuscript database

    Many flat, poorly drained soils, such as the Delmarva Peninsula, the upper Midwest, and certain areas of Europe such as Denmark and Netherlands, have been extensively drained through the construction of artificial drainage ditches and tiles to allow agriculture and other human activities. In additi...

  19. Theory of Maxwell's fish eye with mutually interacting sources and drains

    NASA Astrophysics Data System (ADS)

    Leonhardt, Ulf; Sahebdivan, Sahar

    2015-11-01

    Maxwell's fish eye is predicted to image with a resolution not limited by the wavelength of light. However, interactions between sources and drains may ruin the subwavelength imaging capabilities of this and similar absolute optical instruments. Nevertheless, as we show in this paper, at resonance frequencies of the device, an array of drains may resolve a single source, or alternatively, a single drain may scan an array of sources, no matter how narrowly spaced they are. It seems that near-field information can be obtained from far-field distances.

  20. High efficiency FET microwave detector design

    NASA Astrophysics Data System (ADS)

    Luglio, Juan; Ishii, Thomas Koryu

    1990-12-01

    The work is based on an assumption that very little microwave power would be consumed at a negatively biased gate of a microwave FET, yet significant detected signals would be obtained at the drain if the bias is given. By analyzing a Taylor-series expansion of the drain-current equation in the vicinity of a fixed gate-bias voltage, the bias voltage is found to maximize the second derivative of the drain current, the gate-bias voltage characteristic curve for the maximum detected drain current under a given fixed drain-bias voltage. Based on these findings, a high-efficiency microwave detector is designed, fabricated, and tested at 8.6 GHz, and it is shown that the audio power over absorbed microwave power ratio of the detector is 135 percent due to the positive gain.

  1. Successful Removal of Malpositioned Chest Drain Within the Liver by Embolization of the Transhepatic Track

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tait, Paul; Waheed, Umeer; Bell, Suzanne, E-mail: drsuzy29@hotmail.co

    2009-07-15

    The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfullymore » removed without the complication of bleeding in a patient unsuitable for a general anesthetic.« less

  2. How to remove a chest drain.

    PubMed

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  3. Autotransfusion after total knee arthroplasty. Effects on blood cells, plasma chemistry, and whole blood rheology.

    PubMed

    Dalén, T; Broström, L A; Engström, K G

    1997-08-01

    Postoperative drain blood was collected and reinfused using the ConstaVac system (Stryker, Kalamazoo, MI) in 30 patients after total knee arthroplasty. Of the total 1.1-L volume of postoperative bleeding, 60% was reinfused. No clinical complications were observed. Differences between venous blood and drain blood and between venous blood and drain blood after separate incubation were studied with respect to acidic and inflammatory effects on blood cells, plasma chemistry, and whole blood rheology. In drain blood, leukocyte and platelet counts were reduced (P < .001), probably as a result of consumption in the wound. Acidic incubation occurs in the drain container because of production of lactate from glucose, with a minimum pH at 5 hours of 7.2. The low pH caused slight but significant erythrocyte swelling (P < .01). The complement C3d indicated leukocyte activation, although of modest magnitude. Despite incubation and complement activation, maximum erythrocyte hemolysis after 24 hours of incubation was less than 1%. Drain blood showed a lower resistance against micropore filtration than venous blood (P < .001), mainly because of the reduced number of leukocytes, and remained unchanged with incubation. Although the autotransfusion system can be improved with respect to blood quality, filtered drain blood should be considered acceptable for reinfusion.

  4. Linking selenium sources to ecosystems: San Francisco Bay-Delta Model

    USGS Publications Warehouse

    Presser, Theresa S.; Luoma, Samuel N.

    2004-01-01

    Marine sedimentary rocks of the Coast Ranges contribute selenium to soil, surface water, and ground water in the western San Joaquin Valley, California. Irrigation funnels selenium into a network of subsurface drains and canals. Proposals to build a master drain (i.e., San Luis Drain) to discharge into the San Francisco Bay-Delta Estuary remain as controversial today as they were in the 1950s, when drainage outside the San Joaquin Valley was first considered. An existing 85-mile portion of the San Luis Drain was closed in 1986 after fish mortality and deformities in ducks, grebes and coots were discovered at Kesterson National Wildlife Refuge, the temporary terminus of the drain. A 28-mile portion of the drain now conveys drainage from 100,000 acres into the San Joaquin River and eventually into the Bay-Delta. If the San Luis Drain is extended directly to the Bay-Delta, as is now being proposed as an alternative to sustain agriculture, it could receive drainage from an estimated one-million acres of farmland affected by rising water tables and increasing salinity. In addition to agricultural sources, oil refineries also discharge selenium to the Bay-Delta, although those discharges have declined in recent years. To understand the effects of changing selenium inputs, scientists have developed the Bay-Delta Selenium Model.

  5. Developing an evidence-based nursing protocol on wound drain management for total joint arthroplasty.

    PubMed

    Tsang, Lap Fung

    2015-05-01

    Although various drains have long been used for many years in total joint replacement, there is a paucity of evidence for the benefit of drain applications. Evidence suggests inconsistent practice in the use of drainage systems, whether intermittently applying suction or free of suction in the application of drainage systems, as well as the optimal timing for wound drain removal. It aimed to perform a systematic review to develop an evidence-based nursing protocol to manage wound drainage following total joint arthroplasty. A comprehensive systematic review of available evidence up to 2013. Searches of the EMBASE, Cochrane library, CINAHL, Medline electronic databases and an internet search by Yahoo and Google engine returned 2840 records, of which 11 met the inclusion criteria for this review. A further two papers were obtained through scanning the reference lists of those articles included from the initial literature search. Different clamping times were retrieved from the literature. A protocol was adapted for clinical application according to the summary of the retrieved information. It is suggested that clamping is performed 1 h after the insertion of suction drains post-operatively in the operating theatre. Wound drains should be clamped for 1 h if blood loss is more than 600 ml in 6 h in first 24 h. Wound drains should be clamped for 1 h if blood loss is more than 800 ml in 8 h thereafter. It is suggested that the drainage reservoir bottle should be mark and findings recorded in line with the principle of drain clamping. This means that the amount of drainage is measured and recorded every 6 h in first 24 h and every 8 h thereafter. It is suggested that wound drains should be remove before 48 h after TJR. If blood loss is less than 50 ml in past 6 h or less than 70 ml in past 8 h, the drain should be remove and the wound site should be monitored closely. This paper has guided nurses to develop an evidence-based protocol to improve patient care on wound drain management. Further study is necessary to evaluate the effectiveness of the protocol. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Gummel Symmetry Test on charge based drain current expression using modified first-order hyperbolic velocity-field expression

    NASA Astrophysics Data System (ADS)

    Singh, Kirmender; Bhattacharyya, A. B.

    2017-03-01

    Gummel Symmetry Test (GST) has been a benchmark industry standard for MOSFET models and is considered as one of important tests by the modeling community. BSIM4 MOSFET model fails to pass GST as the drain current equation is not symmetrical because drain and source potentials are not referenced to bulk. BSIM6 MOSFET model overcomes this limitation by taking all terminal biases with reference to bulk and using proper velocity saturation (v -E) model. The drain current equation in BSIM6 is charge based and continuous in all regions of operation. It, however, adopts a complicated method to compute source and drain charges. In this work we propose to use conventional charge based method formulated by Enz for obtaining simpler analytical drain current expression that passes GST. For this purpose we adopt two steps: (i) In the first step we use a modified first-order hyperbolic v -E model with adjustable coefficients which is integrable, simple and accurate, and (ii) In the second we use a multiplying factor in the modified first-order hyperbolic v -E expression to obtain correct monotonic asymptotic behavior around the origin of lateral electric field. This factor is of empirical form, which is a function of drain voltage (vd) and source voltage (vs) . After considering both the above steps we obtain drain current expression whose accuracy is similar to that obtained from second-order hyperbolic v -E model. In modified first-order hyperbolic v -E expression if vd and vs is replaced by smoothing functions for the effective drain voltage (vdeff) and effective source voltage (vseff), it will as well take care of discontinuity between linear to saturation regions of operation. The condition of symmetry is shown to be satisfied by drain current and its higher order derivatives, as both of them are odd functions and their even order derivatives smoothly pass through the origin. In strong inversion region and technology node of 22 nm the GST is shown to pass till sixth-order derivative and for weak inversion it is shown till fifth-order derivative. In the expression of drain current major short channel phenomena like vertical field mobility reduction, velocity saturation and velocity overshoot have been taken into consideration.

  7. Effects of Post-fire Succession and Edaphic Conditions on Tree Transpiration in a Boreal Black Spruce Forest

    NASA Astrophysics Data System (ADS)

    Angstmann, J. L.; Ewers, B. E.; Kwon, H.; Bond-Lamberty, B.; Amiro, B.; Gower, S. T.

    2007-12-01

    Boreal forest ecosystems play an integral role in global climate change because of their large land area and ability to store large quantities of carbon. Quantifying and explaining tree water use in both well- and poorly- drained soils and across successional development is critical in understanding the influence of physiological processes on carbon, water, and energy cycling. Four black spruce stands burned in 1850, 1930, 1964, and 1989 were chosen for this research because they had been shown in previous studies to represent critical stages of forest development that capture the successional impacts of both leaf area and species composition change. We hypothesized that tree transpiration will differ between well- and poorly-drained areas and with age due to 1) tree size and age and edaphic-related hydraulic adjustments and 2) tree size will be explained by species specific growth differences from edaphic conditions. Sap flux, leaf water potential (\\PsiL), site specific allometric relationships between sapwood area and leaf area and soil properties such as texture and organic matter depth in each of the four burn ages were utilized to test these hypotheses. Results show that sap flux for Picea mariana at the 1964 burn age differed between well- and poorly-drained soils when scaled per unit xylem area with trees located on poorly-drained soils experiencing higher sap flux rates than trees in well- drained areas (101.79 & 83.02 g cm-2 day-1 respectively). However, when scaled to transpiration on a per tree basis, taking tree size into account, trees on well-drained soils had higher rates than those in poorly- drained locations (366.96 & 216.82 g tree-1 day-1 respectively). The presence of Pinus banksiana and Populus tremuloides in the well-drained areas increased stand transpiration rates for these areas considerably as compared to the poorly-drained areas. Midday \\PsiL for all four burns show no significant difference between well- and poorly-drained (average midday \\PsiL = -1.23 & -1.29 MPa respectively) sites for Picea mariana (t-value = -0.591, df = 6, p-value = 0.576). This indicates that tree size, which is constrained by growth and anaerobic conditions, drives differences in tree transpiration for well- and poorly-drained soils.

  8. Characterizing subsurface water flow to artificial drain lines using fiber-optic distributed temperature sensing

    NASA Astrophysics Data System (ADS)

    Shults, D.; Brooks, E. S.; Heinse, R.; Keller, C. K.

    2017-12-01

    Over the last several years growers have experienced increasingly wet spring conditions in the Palouse Region located in North Idaho, Eastern Washington and Eastern Oregon. As a result more artificial drain lines are being installed so growers can access their fields earlier in the growing season. Additionally there has been increasing adoption of no-tillage practices among growers in order minimize erosion and runoff in the region. There is a growing body of evidence that suggests long-term no-tillage may lead to the establishment of large macropore networks through increased earthworm activity and the preservation of root channels. These macropore networks, in conjunctions with the presence of artificial drains lines, may create connected preferential flow paths from agricultural fields to receiving streams. This connectivity of flow paths from agricultural fields to receiving water bodies may increase the loading of nutrients and agricultural chemicals as some flow paths may largely bypass soil matrix interaction where materials can be sequestered. Our primary objective for this study was to characterize subsurface flow to two artificial drain lines, one under conventional tillage and the other under no-tillage, using distributed temperature sensing (DTS) technology. During the study (November 2016-April 2017) the near surface soil-water temperature was consistently colder than that of deeper depths. Temperature was thus used as a tracer as snow melt and soil-water moved from the near surface to the drain lines during snowmelt and precipitation events. The spatial and temporal variability of the temperature along the artificial drain line under no-tillage practices was found to be greater than that of the conventional tilled field. It is hypothesized that preferential flow paths are responsible for the increased variability of temperature seen in the drain line under long term no-till management. The temperature along the conventional till drain line showed a dampened response to snow melt and precipitation events during the winter indicating matrix flow was the predominate flow mechanism. In addition to temperature traces, water chemistry (electrical conductivity, pH and nitrate) and discharge measurements were collected at the outlet of each drain line as well as at access ports along the drain lines.

  9. Storm drains as larval development and adult resting sites for Aedes aegypti and Aedes albopictus in Salvador, Brazil.

    PubMed

    Paploski, Igor Adolfo Dexheimer; Rodrigues, Moreno S; Mugabe, Vánio André; Kikuti, Mariana; Tavares, Aline S; Reis, Mitermayer Galvão; Kitron, Uriel; Ribeiro, Guilherme Sousa

    2016-07-27

    Dengue (DENV), Chikungunya (CHIKV), Zika (ZIKV), as well as yellow fever (YFV) viruses are transmitted to humans by Aedes spp. females. In Salvador, the largest urban center in north-eastern Brazil, the four DENV types have been circulating, and more recently, CHIKV and ZIKV have also become common. We studied the role of storm drains as Aedes larval development and adult resting sites in four neighbourhoods of Salvador, representing different socioeconomic, infrastructure and topographic conditions. A sample of 122 storm drains in the four study sites were surveyed twice during a 4-month period in 2015; in 49.0 % of the visits, the storm drains contained water. Adults and immatures of Aedes aegypti were captured in two of the four sites, and adults and immatures of Aedes albopictus were captured in one of these two sites. A total of 468 specimens were collected: 148 Ae. aegypti (38 adults and 110 immatures), 79 Ae. albopictus (48 adults and 31 immatures), and 241 non-Aedes (mainly Culex spp.) mosquitoes (42 adults and 199 immatures). The presence of adults or immatures of Ae. aegypti in storm drains was independently associated with the presence of non-Aedes mosquitoes and with rainfall of ≤ 50 mm during the preceding week. We found that in Salvador, one of the epicentres of the 2015 ZIKV outbreak, storm drains often accumulate water and serve as larval development sites and adult resting areas for both Ae. aegypti and Ae. albopictus. Vector control campaigns usually overlook storm drains, as most of the effort to prevent Ae. agypti reproduction is directed towards containers in the domicile environment. While further studies are needed to determine the added contribution of storm drains for the maintenance of Aedes spp. populations, we advocate that vector control programs incorporate actions directed at storm drains, including regular inspections and use of larvicides, and that human and capital resources are mobilized to modify storm drains, so that they do not serves as larval development sites for Aedes (and other) mosquitoes.

  10. Tracking an Unusual Carbapenemase-producing Organism from Drains to Patient Using Whole Genome Sequencing

    PubMed Central

    Ramsburg, Amanda M; Weingarten, Rebecca A; Conlan, Sean P; Dekker, John P; Michelin, Angela V; Odom, Robin T; Bordner, MaryAnn; Zellmer, Caroline J; Henderson, David K; Segre, Julia A; Frank, Karen M; Palmore, Tara N

    2017-01-01

    Abstract Background The NIH Clinical Center conducts patient and environmental surveillance for carbapenemase-producing organisms (CPO). Previous investigation revealed that sink drains can become colonized with CPO. Subsequent surveillance targets included potential aqueous reservoirs, such as floor drains of environmental services (EVS) closets. Methods Premoistened swabs were used to culture sink drains, floor drains, and equipment for CPO. Perirectal swabs were ordered monthly for all patients in non-behavioral health wards. Specimens were plated to CRE- and ESBL-selective media, and colonies identified by MALDI-TOF. The presence of the blaKPC gene was confirmed by PCR. When environmental CPO isolates were detected, EVS procedures and practices were reviewed. Results In June 2016, blaKPC+ Leclercia adecarboxylata was isolated from an EVS closet floor drain, and in August 2016, from drains in four additional closets. In the previous 10 years, Leclercia sp. was isolated just once from a clinical culture. In September 2016, routine surveillance revealed new-onset blaKPC+ L. adecarboxylata colonization in a stem cell transplant recipient. Investigation included 33 cultures collected from sink and floor drains, EVS equipment, and other items. EVS equipment, especially mop buckets, were identified as a likely point source due to their use in patient care areas and closets with contaminated floor drains. Among seven mop buckets sampled, one grew blaKPC+ L. adecarboxylata. Whole genome sequencing demonstrated genetic relatedness of the Leclercia isolates. Floor cleaner was changed to a disinfectant solution. Extensive decontamination of 67 EVS closets and equipment was performed urgently. No further patient or environmental cultures have grown blaKPC+ L. adecarboxylata. Conclusion The recovery of a highly unusual organism, rarely found in clinical specimens, that was also carrying a blaKPC+ plasmid, allowed us to detect environmental spread of this organism in the hospital. The ability to track this organism using genome sequencing provided strong evidence of the mode of spread, leading to effective remediation. No evidence-based methods exist for remediating drain contamination, which can serve as a potential reservoir for transmission. Disclosures All authors: No reported disclosures.

  11. Surface runoff and subsurface tile drain losses of neonicotinoids and companion herbicides at edge-of-field.

    PubMed

    Chrétien, François; Giroux, Isabelle; Thériault, Georges; Gagnon, Patrick; Corriveau, Julie

    2017-05-01

    With their application as seed coatings, the use of neonicotinoid insecticides increased dramatically during the last decade. They are now frequently detected in aquatic ecosystems at concentrations susceptible to harm aquatic invertebrates at individual and population levels. This study intent was to document surface runoff and subsurface tile drain losses of two common neonicotinoids (thiamethoxam and clothianidin) compared to those of companion herbicides (atrazine, glyphosate, S-metolachlor and mesotrione) at the edge of a 22.5-ha field under a corn-soybean rotation. A total of 14 surface runoff and tile drain discharge events were sampled over two years. Events and annual unit mass losses were computed using flow-weighted concentrations and total surface runoff and tile drain flow volumes. Detection frequencies close to 100% in edge-of-field surface runoff and tile drain water samples were observed for thiamethoxam and clothianidin even though only thiamethoxam had been applied in the first year. In 2014, thiamethoxam median concentrations in surface runoff and tile drain samples were respectively 0.46 and 0.16 μg/L, while respective maximum concentrations of 2.20 and 0.44 μg/L were measured in surface runoff and tile drain samples during the first post-seeding storm event. For clothianidin, median concentrations in surface runoff and tile drain samples were 0.02 and 0.01, μg/L, and respective maximum concentrations were 0.07 μg/L and 0.05 μg/L. Surface runoff and tile drain discharge were key transport mechanisms with similar contributions of 53 and 47% of measured mass losses, respectively. Even if thiamethoxam was applied at a relatively low rate and had a low mass exportation value (0.3%), the relative toxicity was one to two orders of magnitude higher than those of the other chemicals applied in 2014 and 2015. Companion herbicides, except glyphosate in tile drains, exceeded their water quality guideline during one sampling campaign after application but rapidly resumed below these limits. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Comparison of Natural Drainage Group and Negative Drainage Groups after Total Thyroidectomy: Prospective Randomized Controlled Study

    PubMed Central

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum

    2013-01-01

    Purpose The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Materials and Methods Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. Results The amount of drainage during the first 24 hours postoperatively was 41.68±3.93 mL in the negative drain group and 25.3±2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19±4.26 mL and natural drain groups 21.53±2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. Conclusion These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done. PMID:23225820

  13. Use of drains versus no drains after burr-hole evacuation of chronic subdural haematoma: a randomised controlled trial.

    PubMed

    Santarius, Thomas; Kirkpatrick, Peter J; Ganesan, Dharmendra; Chia, Hui Ling; Jalloh, Ibrahim; Smielewski, Peter; Richards, Hugh K; Marcus, Hani; Parker, Richard A; Price, Stephen J; Kirollos, Ramez W; Pickard, John D; Hutchinson, Peter J

    2009-09-26

    Chronic subdural haematoma causes serious morbidity and mortality. It recurs after surgical evacuation in 5-30% of patients. Drains might reduce recurrence but are not used routinely. Our aim was to investigate the effect of drains on recurrence rates and clinical outcomes. We did a randomised controlled trial at one UK centre between November, 2004, and November, 2007. 269 patients aged 18 years and older with a chronic subdural haematoma for burr-hole drainage were assessed for eligibility. 108 were randomly assigned by block randomisation to receive a drain inserted into the subdural space and 107 to no drain after evacuation. The primary endpoint was recurrence needing redrainage. The trial was stopped early because of a significant benefit in reduction of recurrence. Analyses were done on an intention-to-treat basis. This study is registered with the International Standard Randomised Controlled Trial Register (ISRCTN 97314294). Recurrence occurred in ten of 108 (9.3%) people with a drain, and 26 of 107 (24%) without (p=0.003; 95% CI 0.14-0.70). At 6 months mortality was nine of 105 (8.6%) and 19 of 105 (18.1%), respectively (p=0.042; 95% CI 0.1-0.99). Medical and surgical complications were much the same between the study groups. Use of a drain after burr-hole drainage of chronic subdural haematoma is safe and associated with reduced recurrence and mortality at 6 months. Academy of Medical Sciences, Health Foundation, and NIHR Biomedical Research Centre (Neurosciences Theme).

  14. Pancreatic resection without routine intraperitoneal drainage

    PubMed Central

    Fisher, William E; Hodges, Sally E; Silberfein, Eric J; Artinyan, Avo; Ahern, Charlotte H; Jo, Eunji; Brunicardi, F Charles

    2011-01-01

    Background Most surgeons routinely place intraperitoneal drains at the time of pancreatic resection but this practice has recently been challenged. Objective Evaluate the outcome when pancreatic resection is performed without operatively placed intraperitoneal drains. Methods In all, 226 consecutive patients underwent pancreatic resection. In 179 patients drains were routinely placed at the time of surgery and in 47 no drains were placed. Outcomes for these two cohorts were recorded in a prospective database and compared using the χ2- /Fisher's exact test for categorical variables, and Wilcoxon's test for continuous variables. Results Demographic, surgical and pathological details were similar between the two cohorts. Elimination of routine intraperitoneal drainage did not increase the frequency or severity of serious complications. However, when all grades of complications were considered, the number of patients that experienced any complication (65% vs. 47%, P = 0.020) and the median complication severity grade (1 vs. 0, P = 0.027) were increased in the group that had drains placed at the time of surgery. Eliminating intra-operative drains was associated with decreased delayed gastric emptying (24% vs. 9%, P = 0.020) and a trend towards decreased wound infection (12% vs. 2%, P = 0.054). The readmission rate (9% vs. 17% P = 0.007) and number of patients requiring post-operative percutaneous drains (2% vs. 11%, P = 0.001) was higher in patients who did not have operatively placed drains but there was no difference in the re-operation rate (4% vs. 0%, P = 0.210). Conclusion Abandoning the practice of routine intraperitoneal drainage after pancreatic resection may not increase the incidence or severity of severe post-operative complications. PMID:21689234

  15. 40 CFR 86.532-78 - Vehicle preconditioning.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 1978 and Later New Motorcycles; Test Procedures § 86.532-78 Vehicle preconditioning. (a) The vehicle shall be moved to the test area and the following operations performed: (1) The fuel tank(s) shall be drained through the provided fuel tank(s) drain(s) and charged with the specified test fuel, § 86.513, to...

  16. 40 CFR 86.532-78 - Vehicle preconditioning.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 1978 and Later New Motorcycles; Test Procedures § 86.532-78 Vehicle preconditioning. (a) The vehicle shall be moved to the test area and the following operations performed: (1) The fuel tank(s) shall be drained through the provided fuel tank(s) drain(s) and charged with the specified test fuel, § 86.513, to...

  17. 40 CFR 86.532-78 - Vehicle preconditioning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1978 and Later New Motorcycles; Test Procedures § 86.532-78 Vehicle preconditioning. (a) The vehicle shall be moved to the test area and the following operations performed: (1) The fuel tank(s) shall be drained through the provided fuel tank(s) drain(s) and charged with the specified test fuel, § 86.513, to...

  18. 40 CFR 86.532-78 - Vehicle preconditioning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1978 and Later New Motorcycles; Test Procedures § 86.532-78 Vehicle preconditioning. (a) The vehicle shall be moved to the test area and the following operations performed: (1) The fuel tank(s) shall be drained through the provided fuel tank(s) drain(s) and charged with the specified test fuel, § 86.513, to...

  19. 40 CFR 86.532-78 - Vehicle preconditioning.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 1978 and Later New Motorcycles; Test Procedures § 86.532-78 Vehicle preconditioning. (a) The vehicle shall be moved to the test area and the following operations performed: (1) The fuel tank(s) shall be drained through the provided fuel tank(s) drain(s) and charged with the specified test fuel, § 86.513, to...

  20. Dissolved organic carbon loading from the field to watershed scale in tile-drained landscapes

    USDA-ARS?s Scientific Manuscript database

    Dissolved organic carbon (DOC) is an integral part to the functioning of aquatic ecosystems; yet, there is a paucity of data on DOC delivery and management in tile-drained agricultural headwater watersheds. The objective of this study was to quantify the contribution of subsurface tile drains to wat...

  1. Surface Water and Groundwater Nitrogen Dynamics in a Well Drained Riparian Forest within a Poorly Drained Agricultural Landscape

    EPA Science Inventory

    The effectiveness of riparian zones in mitigating nutrients in ground and surface water depends on the climate, management and hydrogeomorphology of a site. The purpose of this study was to determine the efficacy of a well-drained, mixed-deciduous riparian forest to buffer a ri...

  2. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... drain piping for each toilet shall be vented by a 11/2 inch minimum diameter vent or rectangular vent of..., connected to the toilet drain by one of the following methods: (i) A 11/2 inch diameter (min.) individual vent pipe or equivalent directly connected to the toilet drain within the distance allowed in § 3280...

  3. Leaf litter decomposition and macroinvertebrate communities in headwater streams draining pine and hardwood catchments

    Treesearch

    Matt R. Whiles; J. Bruce Wallace

    1997-01-01

    Benthic invertebrates, litter decomposition, and litterbag invertebrates were examined in streams draining pine monoculture and undisturbed hardwood catchments at the Coweeta Hydrologic Laboratory in the southern Appalachian Mountains, USA. Bimonthly benthic samples were collected from a stream draining a pine catchment at Coweeta during 1992, and compared to...

  4. Rethinking "Brain Drain" in the Era of Globalisation

    ERIC Educational Resources Information Center

    Rizvi, Fazal

    2005-01-01

    This paper discusses a range of issues concerning the idea of "brain drain" within the context of recent thinking on transnational mobility. It argues that the traditional analyses of brain drain are not sufficient, and that we can usefully approach the topic from a postcolonial perspective concerned with issues of identity, national…

  5. Greenhouse gas fluxes of drained organic and flooded mineral agricultural soils in the United States

    USDA-ARS?s Scientific Manuscript database

    Drained organic soils for agriculture represent less than 1% of the area used for crops in the United States (US). However, emission of carbon dioxide (CO2) from microbial oxidation of drained organic soils offsets almost half of the contributions that carbon sequestration of other cropping systems ...

  6. Effects of land use and surficial geology on flow and water quality of streams in the coal-mining region of southwestern Indiana, October 1979 through September 1980

    USGS Publications Warehouse

    Wilber, William G.; Renn, Danny E.; Crawford, Charles G.

    1985-01-01

    The effect of surficial geology on stream quality was evident for several dissolved constituents in forested and agricultural watersheds. In general, pH and concentrations of alkalinity and calcium were significantly higher in streams draining the Wisconsin glacial province than in streams draining the Illinoian glacial province and unglaciated regions. The higher pH and concentrations of these constituents suggests that there is greater dissolution of carbonate minerals in the Wisconsin glacial province than the other regions. Median concentrations of arsenic, lead, and manganese for streams draining the Wisconsin glacial province were significantly lower than for those constituents in streams draining the Illinoian province and unglaciated region. The median cadmium concentration for streams draining the Wisconsin glacial province was lower than for streams draining the unglaciated region. These differences may have been due to lower solubilities of metal and trace elements at higher pH values in the Wisconsin glacial province than in the Illinoian glacial province and the unglaciated region.

  7. Water movement and isoproturon behaviour in a drained heavy clay soil: 1. Preferential flow processes

    NASA Astrophysics Data System (ADS)

    Haria, A. H.; Johnson, A. C.; Bell, J. P.; Batchelor, C. H.

    1994-12-01

    The processes and mechanisms that control pesticide transport from drained heavy clay catchments are being studied at Wytham Farm (Oxford University) in southern England. In the first field season field-drain water contained high concentrations of pesticide. Soil studies demonstrated that the main mechanism for pesticide translocation was by preferential flow processes, both over the soil surface and through the soil profile via a macropore system that effectively by-passed the soil matrix. This macropore system included worm holes, shrinkage cracks and cracks resulting from ploughing. Rainfall events in early winter rapidly created a layer of saturation in the A horizon perched above a B horizon of very low hydraulic conductivity. Drain flow was initiated when the saturated layer in the A horizon extended into the upper 0.06m of the soil profile; thereafter water moved down slope via horizontal macropores possibly through a band of incorporated straw residues. These horizontal pathways for water movement connected with the fracture system of the mole drains, thus feeding the drains. Overland flow occurred infrequently during the season.

  8. A comparative study of surgical drain placement and the use of kinesiologic tape to reduce postoperative morbidity after third molar surgery.

    PubMed

    Genc, Aysenur; Cakarer, Sirmahan; Yalcin, Basak Keskin; Kilic, Beril Berivan; Isler, Sabri Cemil; Keskin, Cengizhan

    2018-04-19

    Our aim was to compare the effects of the surgical drain and kinesiotape applications on postoperative morbidity after mandibular third molar surgery in a split-mouth study design. A single-centre, split-mouth study was performed in 23 patients who needed surgical removal of bilateral mandibular third molars. Each patient was treated with a drain tube on one side of the mandible and Kinesio tape (KT) on the contralateral side. Swelling was significantly greater in the KT group than in the drain group throughout the study period. The groups did not differ significantly in the amount of trismus at any time point. The Visual Analogue Scale (VAS)-measured pain intensity was significantly lower in the drainage group. Patients with KT had greater postoperative discomfort than those with a drain tube. All patients were generally satisfied with their treatments. Although both treatments were useful, a surgical drain was significantly more effective at reducing swelling and pain intensity than Kinesio tape. The effects of both on trismus were similar.

  9. A two dimensional analytical modeling of surface potential in triple metal gate (TMG) fully-depleted Recessed-Source/Drain (Re-S/D) SOI MOSFET

    NASA Astrophysics Data System (ADS)

    Priya, Anjali; Mishra, Ram Awadh

    2016-04-01

    In this paper, analytical modeling of surface potential is proposed for new Triple Metal Gate (TMG) fully depleted Recessed-Source/Dain Silicon On Insulator (SOI) Metal Oxide Semiconductor Field Effect Transistor (MOSFET). The metal with the highest work function is arranged near the source region and the lowest one near the drain. Since Recessed-Source/Drain SOI MOSFET has higher drain current as compared to conventional SOI MOSFET due to large source and drain region. The surface potential model developed by 2D Poisson's equation is verified by comparison to the simulation result of 2-dimensional ATLAS simulator. The model is compared with DMG and SMG devices and analysed for different device parameters. The ratio of metal gate length is varied to optimize the result.

  10. The contribution of rice agriculture to methylmercury in surface waters: A review of data from the Sacramento Valley, California

    USGS Publications Warehouse

    Tanner, K. Christy; Windham-Myers, Lisamarie; Fleck, Jacob; Tate, Kenneth W.; McCord, Stephen A.; Linquist, Bruce A.

    2017-01-01

    Methylmercury (MeHg) is a bioaccumulative pollutant produced in and exported from flooded soils, including those used for rice (Oriza sativa L.) production. Using unfiltered aqueous MeHg data from MeHg monitoring programs in the Sacramento River watershed from 1996 to 2007, we assessed the MeHg contribution from rice systems to the Sacramento River. Using a mixed-effects regression analysis, we compared MeHg concentrations in agricultural drainage water from rice-dominated regions (AgDrain) to MeHg concentrations in the Sacramento and Feather Rivers, both upstream and downstream of AgDrain inputs. We also calculated MeHg loads from AgDrains and the Sacramento and Feather Rivers. Seasonally, MeHg concentrations were higher during November through May than during June through October, but the differences varied by location. Relative to upstream, November through May AgDrain least-squares mean MeHg concentration (0.18 ng L−1, range 0.15–0.23 ng L−1) was 2.3-fold higher, while June through October AgDrain mean concentration (0.097 ng L−1, range 0.6–1.6 ng L−1) was not significantly different from upstream. June through October AgDrain MeHg loads contributed 10.7 to 14.8% of the total Sacramento River MeHg load. Missing flow data prevented calculation of the percent contribution of AgDrains in November through May. At sites where calculation was possible, November through May loads made up 70 to 90% of the total annual load. Elevated flow and MeHg concentration in November through May both contribute to the majority of the AgDrain MeHg load occurring during this period. Methylmercury reduction efforts should target elevated November through May MeHg concentrations in AgDrains. However, our findings suggest that the contribution and environmental impact of rice is an order of magnitude lower than previous studies in the California Yolo Bypass.

  11. Small-bore wire-guided chest drains: safety, tolerability, and effectiveness in pneumothorax, malignant effusions, and pleural empyema.

    PubMed

    Cafarotti, Stefano; Dall'Armi, Valentina; Cusumano, Giacomo; Margaritora, Stefano; Meacci, Elisa; Lococo, F; Vita, M L; Porziella, V; Bonassi, S; Cesario, Alfredo; Granone, Pierluigi

    2011-03-01

    The use of small-bore wire-guided chest drains for pleural effusions and pneumothorax has become popular; however, limited data are available on its efficacy and morbidity. The aim of this retrospective study is to measure, via the analysis of the so far largest reported cohort, the efficacy, safety, and tolerability of this approach in different clinical conditions. In the period from January 2002 to December 2008, 1092 patients have undergone the positioning of a small-bore wire-guided chest drain (12F) for the evidence of pneumothorax or pleural effusion and have been monitored over time for morbidity, pain at the time of insertion (measured via the visual analogue scale), and drain failure for misplacement or blockage. Patients with trauma were excluded from this study. Male/female ratio and mean age were respectively 418:674 and 55.85 ± 18.6. Three-hundred ninety-nine (36.5%) drains were inserted for pneumothorax, 324 (29.7%) for malignant effusion, 97 (8.9%) for empyema, and 272 (24.9%) for nonmalignant effusion. The pain experience was on average "very mild" (mean visual analogue scale = 4.6 mm). The overall drain failure rate was 12.9%. The percentage of successful cases was 93.8% in malignant effusion, 93% in pneumothorax, and 92.3% in nonmalignant effusion; in the cases of pathologically diagnosed empyema, drains were more likely to get blocked (74.2%). We recorded 1 serious complication within the malignant effusion group. Wire-guided 12F Seldinger-type drains are a well-tolerated and effective method of treating pneumothorax and uncomplicated pleural effusions (malignant and nonmalignant) with acceptable morbidity. The use of 12F small-bore chest drain is not indicated for the treatment of empyema. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. Determining optimal fluid and air leak cut off values for chest drain management in general thoracic surgery

    PubMed Central

    Mesa-Guzman, Miguel; Periklis, Perikleous; Niwaz, Zakiyah; Socci, Laura; Raubenheimer, Hilgardt; Adams, Ben; Gurung, Lokesh; Uzzaman, Mohsin

    2015-01-01

    Background Chest drain duration is one of the most important influencing aspects of hospital stay but the management is perhaps one of the most variable aspects of thoracic surgical care. The aim of our study is to report outcomes associated with increasing fluid and air leak criteria of protocol based management. Methods A 6-year retrospective analysis of protocolised chest drain management starting in 2007 with a fluid criteria of 3 mL/kg increasing to 7 mL/kg in 2011 to no fluid criteria in 2012, and an air leak criteria of 24 hours without leak till 2012 when digital air leak monitoring was introduced with a criteria of <20 mL/min of air leak for more than 6 hours. Patient data were obtained from electronic hospital records and digital chest films were reviewed to determine the duration of chest tube drainage and post-drain removal complications. Results From 2009 to 2012, 626 consecutive patients underwent thoracic surgery procedures under a single consultant. A total of 160 did not require a chest drain and data was missing in 22, leaving 444 for analysis. The mean age [standard deviation (SD)] was 57±19 years and 272 (61%) were men. There were no differences in the incidence of pneumothoraces (P=0.191), effusion (P=0.344) or re-interventions (P=0.431) for drain re-insertions as progressively permissive criteria were applied. The median drain duration dropped from 1-3 days (P<0.001) and accordingly hospital stay reduced from 4-6 days (P<0.001). Conclusions Our results show that chest drains can be safely removed without fluid criteria and air leak of less than 20 mL/min with median drain duration of 1 day, associated with a reduced length of hospital stay. PMID:26716045

  13. Difference in growth and coalescing patterns of droplets on bi-philic surfaces with varying spatial distribution.

    PubMed

    Garimella, Martand Mayukh; Koppu, Sudheer; Kadlaskar, Shantanu Shrikant; Pillutla, Venkata; Abhijeet; Choi, Wonjae

    2017-11-01

    This paper reports the condensation and subsequent motion of water droplets on bi-philic surfaces, surfaces that are patterned with regions of different wettability. Bi-philic surfaces can enhance the water collection efficiency: droplets condensing on hydrophobic regions wick into hydrophilic drain channels when droplets grow to a certain size, renewing the condensation on the dry hydrophobic region. The onset of drain phenomenon can be triggered by multiple events with distinct nature ranging from gravity, direct contact between a droplet and a drain channel, to a mutual coalescence between droplets. This paper focuses on the effect of the length scale of hydrophobic regions on the dynamics of mutual coalescence between droplets and subsequent drainage. The main hypothesis was that, when the drop size is sufficient, the kinetic energy associated with a coalescence of droplets may cause dynamic advancing of a newly formed drop, leading to further coalescence with nearby droplets and ultimately to a chain reaction. We fabricate bi-philic surfaces with hydrophilic and hydrophobic stripes, and the result confirms that coalescing droplets, when the length scale of droplets increases beyond 0.2mm, indeed display dynamic expansion and chain reaction. Multiple droplets can thus migrate to hydrophilic drain simultaneously even when the initial motion of the droplets was not triggered by the direct contact between the droplet and the hydrophilic drain. Efficiency of drain due to mutual coalescence of droplets varies depending on the length scale of bi-philic patterns, and the drain phenomenon reaches its peak when the width of hydrophobic stripes is between 800μm and 1mm. The Ohnesorge number of droplets draining on noted surfaces is between 0.0042 and 0.0037 respectively. The observed length scale of bi-philic patterns matches that on the Stenocara beetle's fog harvesting back surface. This match between length scales suggests that the surface of the insect is optimized for the drain of harvested water. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Ecotoxicologic impacts of agricultural drain water in the Salinas River, California, USA.

    PubMed

    Anderson, Brian S; Hunt, John W; Phillips, Bryn M; Nicely, Patricia A; Gilbert, Kristine D; de Vlaming, Victor; Connor, Valerie; Richard, Nancy; Tjeerdema, Ronald S

    2003-10-01

    The Salinas River is the largest of the three rivers that drain into the Monterey Bay National Marine Sanctuary in central California (USA). Large areas of this watershed are cultivated year-round in row crops, and previous laboratory studies have demonstrated that acute toxicity of agricultural drain water to Ceriodaphnia dubia is caused by the organophosphate (OP) pesticides chlorpyrifos and diazinon. We investigated chemical contamination and toxicity in waters and sediments in the river downstream of an agricultural drain water input. Ecological impacts of drain water were investigated by using bioassessments of macroinvertebrate community structure. Toxicity identification evaluations were used to characterize chemicals responsible for toxicity. Salinas River water downstream of the agricultural drain was acutely toxic to the cladoceran Ceriodaphnia dubia, and toxicity to C. dubia was highly correlated with combined toxic units (TUs) of chlorpyrifos and diazinon. Laboratory tests were used to demonstrate that sediments in this system were acutely toxic to the amphipod Hyalella azteca, a resident invertebrate. Toxicity identification evaluations (TIEs) conducted on sediment pore water suggested that toxicity to amphipods was due in part to OP pesticides; concentrations of chlorpyrifos in pore water sometimes exceeded the 10-d mean lethal concentration (LC50) for H. azteca. Potentiation of toxicity with addition of the metabolic inhibitor piperonyl butoxide suggested that sediment toxicity also was due to other non-metabolically activated compounds. Macroinvertebrate community structure was highly impacted downstream of the agricultural drain input, and a number of macroinvertebrate community metrics were negatively correlated with combined TUs of chlorpyrifos and diazinon, as well as turbidity associated with the drain water. Some macroinvertebrate metrics were also correlated with bank vegetation cover. This study suggests that pesticide pollution is the likely cause of ecological damage in the Salinas River, and this factor may interact with other stressors associated with agricultural drain water to impact the macroinvertebrate community in the system.

  15. 37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING SYSTEM. NOTE SPIGOT UNDER BOARD AT UPPER LEFT INSERTS INTO HOLE IN PIPE AT BOTTOM OF FRAME. CYANIDE SOLUTION WAS PUMPED INTO THE TANKS AND THE PREGNANT SOLUTION DRAINED OUT OF THE TANKS THROUGH THIS PIPE, AND BACK INTO A SEPARATE HOLDING TANK ON THE EAST SIDE OF THE MILL. TAILINGS WERE REMOVED FROM THE TANKS THROUGH THE ROUND DRAIN DOOR IN THE BOTTOM OF THE TANK (MISSING) SEEN AT TOP CENTER. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA

  16. Draining characteristics of hemispherically bottomed cylinders in a low-gravity environment

    NASA Technical Reports Server (NTRS)

    Symons, E. P.

    1978-01-01

    An experimental investigation was conducted to study the phenomenon of vapor ingestion during the draining of a scale model, hemispherically bottomed cylindrical tank in a low-gravity environment. Where possible, experimental results are compared with previously obtained numerical predictions. It was observed that certain combinations of Weber and Bond number resulted in draining-induced axisymmetric slosh motion. The periods of the slosh waves were correlated with the square root of the draining parameter, the ratio (Weber number)/(Bond number plus one), as was the quantity of liquid remaining in the tank when vapor was ingested into the outlet line.

  17. Advances in chest drain management in thoracic disease

    PubMed Central

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  18. N Channel JFET Based Digital Logic Gate Structure

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J (Inventor)

    2013-01-01

    An apparatus is provided that includes a first field effect transistor with a source tied to zero volts and a drain tied to voltage drain drain (Vdd) through a first resistor. The apparatus also includes a first node configured to tie a second resistor to a third resistor and connect to an input of a gate of the first field effect transistor in order for the first field effect transistor to receive a signal. The apparatus also includes a second field effect transistor configured as a unity gain buffer having a drain tied to Vdd and an uncommitted source.

  19. The effects of vault drainage on postoperative morbidity after vaginal hysterectomy for benign gynaecological disease: a randomised controlled trial.

    PubMed

    Dua, A; Galimberti, A; Subramaniam, M; Popli, G; Radley, S

    2012-02-01

    To evaluate the efficacy of vault drainage in reducing the immediate postoperative morbidity associated with vaginal hysterectomy carried out for benign gynaecological conditions. Randomised controlled trial. A tertiary referral gynaecology centre in UK. A total of 272 women who underwent vaginal hysterectomy for benign conditions between March 2005 and June 2010. The 272 women were randomised to have a drain inserted or not inserted, 'drain' or 'no drain', respectively, before vault closure during vaginal hysterectomy, using a sealed envelope technique. The surgical procedures were performed using the surgeons' standard technique and postoperative care was delivered according to the unit's protocol. The primary outcome measure was reduction in postoperative febrile morbidity. Secondary outcome measures were hospital readmission rate, blood transfusion, change in postoperative haemoglobin and length of stay. In all, 135 women were randomised to have a drain and 137 to 'no drain'. There were no differences in the incidence of febrile morbidity, length of stay, change in haemoglobin or need for postoperative blood transfusion between the two groups. The routine use of vault drain at vaginal hysterectomy for benign disorders has no significant effect on postoperative morbidity. The use of vault drain in this context is not recommended. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  20. Meta-Analysis of Drainage Versus No Drainage After Laparoscopic Cholecystectomy

    PubMed Central

    Lucarelli, Pierino; Di Filippo, Annalisa; De Angelis, Francesco; Stipa, Francesco; Spaziani, Erasmo

    2014-01-01

    Background and Objectives: Routine drainage after laparoscopic cholecystectomy is still controversial. This meta-analysis was performed to assess the role of drains in reducing complications in laparoscopic cholecystectomy. Methods: An electronic search of Medline, Science Citation Index Expanded, Scopus, and the Cochrane Library database from January 1990 to June 2013 was performed to identify randomized clinical trials that compare prophylactic drainage with no drainage in laparoscopic cholecystectomy. The odds ratio for qualitative variables and standardized mean difference for continuous variables were calculated. Results: Twelve randomized controlled trials were included in the meta-analysis, involving 1939 patients randomized to a drain (960) versus no drain (979). The morbidity rate was lower in the no drain group (odds ratio, 1.97; 95% confidence interval, 1.26 to 3.10; P = .003). The wound infection rate was lower in the no drain group (odds ratio, 2.35; 95% confidence interval, 1.22 to 4.51; P = .01). Abdominal pain 24 hours after surgery was less severe in the no drain group (standardized mean difference, 2.30; 95% confidence interval, 1.27 to 3.34; P < .0001). No significant difference was present with respect to the presence and quantity of subhepatic fluid collection, shoulder tip pain, parenteral ketorolac consumption, nausea, vomiting, and hospital stay. Conclusion: This study was unable to prove that drains were useful in reducing complications in laparoscopic cholecystectomy. PMID:25516708

  1. Non-equilibrium Green's functions study of discrete dopants variability on an ultra-scaled FinFET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valin, R., E-mail: r.valinferreiro@swansea.ac.uk; Martinez, A., E-mail: a.e.Martinez@swansea.ac.uk; Barker, J. R., E-mail: john.barker@glasgow.ac.uk

    In this paper, we study the effect of random discrete dopants on the performance of a 6.6 nm channel length silicon FinFET. The discrete dopants have been distributed randomly in the source/drain region of the device. Due to the small dimensions of the FinFET, a quantum transport formalism based on the non-equilibrium Green's functions has been deployed. The transfer characteristics for several devices that differ in location and number of dopants have been calculated. Our results demonstrate that discrete dopants modify the effective channel length and the height of the source/drain barrier, consequently changing the channel control of the charge. Thismore » effect becomes more significant at high drain bias. As a consequence, there is a strong effect on the variability of the on-current, off-current, sub-threshold slope, and threshold voltage. Finally, we have also calculated the mean and standard deviation of these parameters to quantify their variability. The obtained results show that the variability at high drain bias is 1.75 larger than at low drain bias. However, the variability of the on-current, off-current, and sub-threshold slope remains independent of the drain bias. In addition, we have found that a large source to drain current by tunnelling current occurs at low gate bias.« less

  2. Optimization of limestone drains for long- term treatment of acidic mine drainage, Swatara Creek Basin, Schuylkill County, PA

    USGS Publications Warehouse

    Cravotta, Charles A.; Ward, S.J.; Koury, Daniel J.; Koch, R.D.

    2004-01-01

    Limestone drains were constructed in 1995, 1997, and 2000 to treat acidic mine drainage (AMD) from the Orchard, Buck Mtn., and Hegins discharges, respectively, in the Swatara Creek Basin, Southern Anthracite Coalfield, east-central Pennsylvania. This report summarizes the construction characteristics and performance of each of the limestone drains on the basis of influent and effluent quality and laboratory tests of variables affecting limestone dissolution rates. Data for influent and effluent indicate substantial alkalinity production by the Orchard and Buck Mtn. limestone drains and only marginal benefits from the Hegins drain. Nevertheless, the annual alkalinity loading rates have progressively declined with age of all three systems. Collapsible-container (cubitainer) testing was conducted to evaluate current scenarios and possible options for reconstruction and maintenance of the limestone drains to optimize their long-term performance. The cubitainer tests indicated dissolution rates for the current configurations that were in agreement with field flux data (net loading) for alkalinity and dissolved calcium. The dissolution rates in cubitainers were larger for closed conditions than open conditions, but the rates were comparable for coated and uncoated limestone for a given condition. Models developed on the basis of the cubitainer testing indicate (1) exponential declines in limestone mass and corresponding alkalinity loading rates with increased age of limestone drains and (2) potential for improved performance with enlargement, complete burial, and/or regular flushing of the systems.

  3. Method of making self-aligned lightly-doped-drain structure for MOS transistors

    DOEpatents

    Weiner, Kurt H.; Carey, Paul G.

    2001-01-01

    A process for fabricating lightly-doped-drains (LDD) for short-channel metal oxide semiconductor (MOS) transistors. The process utilizes a pulsed laser process to incorporate the dopants, thus eliminating the prior oxide deposition and etching steps. During the process, the silicon in the source/drain region is melted by the laser energy. Impurities from the gas phase diffuse into the molten silicon to appropriately dope the source/drain regions. By controlling the energy of the laser, a lightly-doped-drain can be formed in one processing step. This is accomplished by first using a single high energy laser pulse to melt the silicon to a significant depth and thus the amount of dopants incorporated into the silicon is small. Furthermore, the dopants incorporated during this step diffuse to the edge of the MOS transistor gate structure. Next, many low energy laser pulses are used to heavily dope the source/drain silicon only in a very shallow region. Because of two-dimensional heat transfer at the MOS transistor gate edge, the low energy pulses are inset from the region initially doped by the high energy pulse. By computer control of the laser energy, the single high energy laser pulse and the subsequent low energy laser pulses are carried out in a single operational step to produce a self-aligned lightly-doped-drain-structure.

  4. Effect of defect creation and migration on hump characteristics of a-InGaZnO thin film transistors under long-term drain bias stress with light illumination

    NASA Astrophysics Data System (ADS)

    Cho, Yong-Jung; Kim, Woo-Sic; Lee, Yeol-Hyeong; Park, Jeong Ki; Kim, Geon Tae; Kim, Ohyun

    2018-06-01

    We investigated the mechanism of formation of the hump that occurs in the current-voltage I-V characteristics of amorphous InGaZnO (a-IGZO) thin film transistors (TFTs) that are exposed to long-term drain bias stress under illumination. Transfer characteristics showed two-stage degradation under the stress. At the beginning of the stress, the I-V characteristics shifted in the negative direction with a degradation of subthreshold slope, but the hump phenomenon developed over time in the I-V characteristics. The development of the hump was related to creation of defects, especially ionized oxygen vacancies which act as shallow donor-like states near the conduction-band minimum in a-IGZO. To further investigate the hump phenomenon we measured a capacitance-voltage C-V curve and performed two-dimensional device simulation. Stretched-out C-V for the gate-to-drain capacitance and simulated electric field distribution which exhibited large electric field near the drain side of TFT indicated that VO2+ were generated near the drain side of TFT, but the hump was not induced when VO2+ only existed near the drain side. Therefore, the degradation behavior under DBITS occurred because VO2+ were created near the drain side, then were migrated to the source side of the TFT.

  5. Controlling attachment and growth of Listeria monocytogenes in PVC model floor drains using a peroxide chemical, chitosan/arginine or heat

    USDA-ARS?s Scientific Manuscript database

    Listeria monocytogenes enters a poultry further processing plant with raw product and colonizes the plant as a resident in floor drains. We have shown that L. monocytogenes can escape floor drains, becoming airborne during wash down, creating potential for contamination of fully cooked product. Li...

  6. Controlling attachment and growth of listeria monocytogenes in polyvinyl chloride model floor drains using a peroxide chemical, chitosan-arginine, or heat

    USDA-ARS?s Scientific Manuscript database

    Listeria monocytogenes can colonize a poultry processing or further processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross contamination of product. The objective of this study was to compare a synthetic hydrogen per...

  7. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  8. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  9. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  10. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  11. 19 CFR 159.22 - Net weights and tares.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... tins imported from Spain: The following schedule drained weight shall be used as the Customs dutiable... in tins and such drained weight being the allowance made in liquidation for tare for water: Size can Drained weight 3 kilo 13.6 kilograms-case of 6 tins. 794 grams 16.7 kilograms-case of 24 tins. 425 grams 8...

  12. 19 CFR 159.22 - Net weights and tares.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... tins imported from Spain: The following schedule drained weight shall be used as the Customs dutiable... in tins and such drained weight being the allowance made in liquidation for tare for water: Size can Drained weight 3 kilo 13.6 kilograms-case of 6 tins. 794 grams 16.7 kilograms-case of 24 tins. 425 grams 8...

  13. 19 CFR 159.22 - Net weights and tares.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... tins imported from Spain: The following schedule drained weight shall be used as the Customs dutiable... in tins and such drained weight being the allowance made in liquidation for tare for water: Size can Drained weight 3 kilo 13.6 kilograms-case of 6 tins. 794 grams 16.7 kilograms-case of 24 tins. 425 grams 8...

  14. 19 CFR 159.22 - Net weights and tares.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... tins imported from Spain: The following schedule drained weight shall be used as the Customs dutiable... in tins and such drained weight being the allowance made in liquidation for tare for water: Size can Drained weight 3 kilo 13.6 kilograms-case of 6 tins. 794 grams 16.7 kilograms-case of 24 tins. 425 grams 8...

  15. 19 CFR 159.22 - Net weights and tares.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... tins imported from Spain: The following schedule drained weight shall be used as the Customs dutiable... in tins and such drained weight being the allowance made in liquidation for tare for water: Size can Drained weight 3 kilo 13.6 kilograms-case of 6 tins. 794 grams 16.7 kilograms-case of 24 tins. 425 grams 8...

  16. An Exact Solution to the Draining Reservoir Problem of the Incompressible and Non-Viscous Liquid

    ERIC Educational Resources Information Center

    Hong, Seok-In

    2009-01-01

    The exact expressions for the drain time and the height, velocity and acceleration of the free surface are found for the draining reservoir problem of the incompressible and non-viscous liquid. Contrary to the conventional approximate results, they correctly describe the initial time dependence of the liquid velocity and acceleration. Torricelli's…

  17. Development of Thermal Bridging Factors for Use in Energy Models

    DTIC Science & Technology

    2015-06-20

    assemblies. 5.2.2 Drainage : Drained systems Drained (Figure 5-6) and screened enclosures assume some rainwater will penetrate the outer surface...38 5.2.2 Drainage : Drained systems ...layer (e.g., drainage plane and gap or waterproofing) 2. Airflow control layer (e.g., an air barrier system ) 3. Thermal control layer (e.g., insulation

  18. Novel pod for chlorine dioxide generation and delivery to control aerobic bacteria on the inner surface of floor drains

    USDA-ARS?s Scientific Manuscript database

    Floor drains in poultry processing and further processing plants are a harborage site for bacteria both free swimming and in biofilms. This population can include Listeria monocytogenes which has been shown to have potential for airborne spreading from mishandled open drains. Chlorine dioxide (ClO...

  19. 75 FR 29520 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... section 1404(b) of the Act (``Drain Cover Standard''). In addition to the anti-entrapment devices or... system; gravity drainage system; automatic pump shut-off system or drain disablement. The Pool and Spa... the drain covers, anti-entrapment device/systems, sump or equalizer lines at the site; and report on...

  20. Influence of thinning operations on the hydrology of a drained coastal plantation watershed

    Treesearch

    Johnny M. Grace; R.W. Skaggs; H.R. Malcom; G.M. Chescheir; D.K. Cassel

    2003-01-01

    Forest management activities such as harvesting, thinning, and site preparation can affect the hydrologic behavior of watersheds on poorly drained soils. The effects of thinning on hydrology are presented for an artificially drained pine plantation paired watershed in eastern North Carolina. Outflow and water table depths were monitored over a 3-year study period...

  1. 30 CFR 816.72 - Disposal of excess spoil: Valley fills/head-of-hollow fills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., 6-hour precipitation event. (b) Rock-core chimney drains. A rock-core chimney drain may be used in a... as the fill is not located in an area containing intermittent or perennial streams. A rock-core... upstream drainage is diverted around the fill. The alternative rock-core chimney drain system shall be...

  2. Disinfection of drain water of tomato by means of UV radiation and slow sand filtration in real greenhouse circumstances.

    PubMed

    De Rocker, E; Goen, K; Van Poucke, K

    2006-01-01

    The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.

  3. 77 FR 70357 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... replacing the drain tube assemblies and support clamps on the aft fairing of the engine struts. This new AD requires replacing the drain tube assembly of the left and right engine strut aft fairings with a new one... require replacing the drain tube assembly of the left and right engine strut aft fairings with a new one...

  4. Volatilization of low vapor pressure--volatile organic compounds (LVP-VOCs) during three cleaning products-associated activities: Potential contributions to ozone formation.

    PubMed

    Shin, Hyeong-Moo; McKone, Thomas E; Bennett, Deborah H

    2016-06-01

    There have been many studies to reduce ozone formation mostly from volatile organic compound (VOC) sources. However, the role of low vapor pressure (LVP)-VOCs from consumer products remains mostly unexplored and unaddressed. This study explores the impact of high production volume LVP-VOCs on ozone formation from three cleaning products-associated activities (dishwashing, clothes washing, and surface cleaning). We develop a model framework to account for the portion available for ozone formation during the use phase and from the down-the-drain disposal. We apply experimental studies that measured emission rates or models that were developed for estimating emission rates of organic compounds during the use phase. Then, the fraction volatilized (fvolatilized) and the fraction disposed down the drain (fdown-the-drain) are multiplied by the portion available for ozone formation for releases to the outdoor air (fO3|volatilized) and down-the-drain (fO3|down-the-drain), respectively. Overall, for chemicals used in three specific cleaning-product uses, fvolatilized is less than 0.6% for all studied LVP-VOCs. Because greater than 99.4% of compounds are disposed of down the drain during the use phase, when combined with fO3|volatilized and fO3|down-the-drain, the portion available for ozone formation from the direct releases to outdoor air and the down-the-drain disposal is less than 0.4% and 0.2%, respectively. The results from this study indicate that the impact of the studied LVP-VOCs on ozone formation is very sensitive to what occurs during the use phase and suggest the need for future research on experimental work at the point of use. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Postoperative drainage in head and neck surgery.

    PubMed

    Amir, Ida; Morar, Pradeep; Belloso, Antonio

    2010-11-01

    A major factor affecting patients' length of hospitalisation following head and neck surgery remains the use of surgical drains. The optimal time to remove these drains has not been well defined. A routine practice is to measure the drainage every 24 h and remove the drain when daily drainage falls below 25 ml. This study aims to determine whether drainage measurement at shorter intervals decreases the time to drain removal and hence the length of in-patient stays. A 6-month prospective observational study was performed. The inclusion criteria were patients who underwent head and neck surgery without neck dissection and had a closed suction drain inserted. Drainage rates were measured at 8-hourly intervals. Drains were removed when drainage-rate was ≤ 1 ml/h over an 8-h period. A total of 43 patients were evaluated. The highest drainage rate occurred in the first 8 postoperative hours and decreased significantly in the subsequent hours. The median drainage rates at 8, 16, 24, 32 and 40 postoperative hours were 3.375, 1, 0, 0 and 0 ml/h, respectively. Applying our new removal criteria of ≤ 1 ml/h drainage rate, the drains were removed in 22 (51%) patients at the 16th postoperative hour; 37 (86%) were removed by 24 h after operation. In comparison, only nine (20.9%) patients could potentially be discharged the day after surgery if previous criteria of ≤ 25 ml/24-h were used to decide on drain removal. Our 8-hourly drainage-rate monitoring has facilitated safe earlier discharge of an additional 28 (65%) patients on the day after surgery. This has led to improvement in patient care, better optimisation of hospital resources and resulted in positive economic implications to the department.

  6. Occurrence and seasonal variations of per- and polyfluoroalkyl substances (PFASs) including fluorinated alternatives in rivers, drain outlets and the receiving Bohai Sea of China.

    PubMed

    Chen, Hong; Han, Jianbo; Zhang, Can; Cheng, Jiayi; Sun, Ruijun; Wang, Xiaomeng; Han, Gengchen; Yang, Wenchao; He, Xin

    2017-12-01

    A simultaneous sampling campaign was undertaken to study the pollution by 21 per- and polyfluoroalkyl substances (PFASs) in rivers, drain outlets and their receiving Bohai Sea of China. Chlorinated polyfluoroalkyl ether sulfonic acids (Cl-PFESAs) are being used as fluorinated alternatives and they were included in this study. In comparison with other regions and countries, high concentrations of ∑ 21 PFASs in seawater samples from the Bohai Sea, ranging from 5.03 to 41 700 ng/L (median: 64.8 ng/L), were observed. The spatial distribution of PFAS levels in this sea area was in the ranking of Laizhou Bay > Liaodong Bay > Bohai Bay > other sea areas. By comparing the levels and composition profiles of PFASs in the seawater and their sources (rivers and drain outlets), it was concluded that rivers and drain outlets are the primary sources of PFAS contamination to the Bohai Sea. These PFAS levels varied seasonally among the rivers and drain outlets, but statistically significant changes were not observed. Levels of 6:2 and 8:2 Cl-PFESAs in rivers, drain outlets and receiving sea were firstly reported in the present study. Relatively high concentrations of 6:2 Cl-PFESA were found in drain outlets, ranging from below method limits of quantification (MLQ) to 7600 ng/L, but 8:2 Cl-PFAES detection was infrequent and all median concentration below MLQ. Mass discharges to the sea of 6:2 Cl-PFESA from rivers and drain outlets to the sea were estimated to be 37 and 17 kg/y, respectively. Copyright © 2017. Published by Elsevier Ltd.

  7. Runoff losses of sediment and phosphorus from no-till and cultivated soils receiving dairy manure.

    PubMed

    Verbree, David A; Duiker, Sjoerd W; Kleinman, Peter J A

    2010-01-01

    Managing manure in no-till systems is a water quality concern because surface application of manure can enrich runoff with dissolved phosphorus (P), and incorporation by tillage increases particulate P loss. This study compared runoff from well-drained and somewhat poorly drained soils under corn (Zea mays, L.) production that had been in no-till for more than 10 yr. Dairy cattle (Bos taurus L.) manure was broadcast into a fall planted cover crop before no-till corn planting or incorporated by chisel/disk tillage in the absence of a cover crop. Rainfall simulations (60 mm h(-1)) were performed after planting, mid-season, and post-harvest in 2007 and 2008. In both years and on both soils, no-till yielded significantly less sediment than did chisel/disking. Relative effects of tillage on runoff and P loss differed with soil. On the well-drained soil, runoff depths from no-till were much lower than with chisel/disking, producing significantly lower total P loads (22-50% less). On the somewhat poorly drained soil, there was little to no reduction in runoff depth with no-till, and total P loads were significantly greater than with chisel/disking (40-47% greater). Particulate P losses outweighed dissolved P losses as the major concern on the well-drained soil, whereas dissolved P from surface applied manure was more important on the somewhat poorly drained soil. This study confirms the benefit of no-till to erosion and total P runoff control on well-drained soils but highlights trade-offs in no-till management on somewhat poorly drained soils where the absence of manure incorporation can exacerbate total P losses.

  8. Source-drain burnout mechanism of GaAs power MESFETS: Three terminal effects

    NASA Astrophysics Data System (ADS)

    Takamiya, Saburo; Sonoda, Takuji; Yamanouchi, Masahide; Fujioka, Takashi; Kohno, Masaki

    1997-03-01

    Theoretical expressions for thermal and electrical feedback effects are derived. These limit the power capability of a power FET and lead a device to catastrophic breakdown (source-drain burnout) when the loop gain of the former reaches unity. Field emission of thermally excited electrons at the Schottky gate plays the key role in thermal feedback, while holes being impact ionized by the drain current play a similar role in the electrical feedback. Thermal feedback is dominant in a high temperature and low drain voltage area. Electrical feedback is dominant in a high drain voltage and low temperature area. In the first area, a high junction temperature is the main factor causing the thermal runaway of the device. In the second area, the electrcal feedback increases the drain current and the temperature and gives a trigger to the thermal feedback so that it reaches unity more easily. Both effects become significant in proportion to transconductance and gate bias resistance, and cause simultaneous runaway of the gate and drain currents. The expressions of the loop gains clearly indicate the safe operating conditions for a power FET. C-band 4 W (1 chip) and 16 W (4 chip) GaAs MESFETs were used as the experimental samples. With these devices the simultaneous runaway of the gate and the drain currents, apparent dependence of the three teminal breakdown voltage on the gate bias resistance in the region dominated by electrical feedback, the rapid increase of the field emitted current at the critical temperature and clear coincidence between the measured and calculated three terminal gate currents both in the thermal feedback dominant region, etc. are demonstrated. The theory explains the experimental results well.

  9. Gauze Impregnated With Quaternary Ammonium Salt Reduces Bacterial Colonization of Surgical Drains After Breast Reconstruction.

    PubMed

    Strong, Amy L; Wolfe, Emily T; Shank, Nina; Chaffin, Abigail E; Jansen, David A

    2018-06-01

    Surgical site infection after breast reconstruction is associated with increased length of hospital stay, readmission rates, cost, morbidity, and mortality. Identifying methods to reduce surgical site infection without the use of antibiotics may be beneficial at reducing antimicrobial resistance, reserving the use of antibiotics for more severe cases. Quaternary ammonium salts have previously been shown to be a safe and effective antimicrobial agent in the setting of in vitro and in vivo animal experiments. A retrospective study was conducted to investigate the antimicrobial properties of a quaternary ammonium salt, 3-trimethoxysilyl propyldimethyloctadecyl ammonium chloride (QAS-3PAC; Bio-spear), at reducing surgical drain site colonization and infection after breast reconstruction (deep inferior epigastric perforator flap reconstruction or tissue expander placement). Twenty patients were enrolled, with 14 surgical drains covered with nonimpregnated gauze and 17 surgical drains covered with QAS-3PAC impregnated gauze, for the purposes of investigating bacterial colonization. Antibiotic sensitivity analysis was also conducted when bacterial cultures were positive. The overall incidence of bacterial colonization of surgical drains was lower in the treatment group compared with the control group (17.6% vs 64.3%, respectively; P = 0.008). QAS-3PAC impregnated gauze reduced the incidence of bacterial colonization of surgical drains during the first (0.0% vs 33.3%) and second (33.3% vs 87.5%; P = 0.04) postoperative week. Furthermore, no enhanced antibiotic resistance was noted on drains treated with QAS-3PAC impregnated gauze. The results of this study suggest that QAS-3PAC impregnated gauze applied over surgical drains may be an effective method for reducing the incidence of bacterial colonization.

  10. Anatomical variations in the pattern of the right hepatic veins draining the posterior segment of the right lobe of the liver.

    PubMed

    Shilal, Poonam; Tuli, Anita

    2015-03-01

    The pattern of drainage in the right posterior lobe of liver varies considerably. The knowledge of this variation is very important while performing various surgeries on the right posterior lobe. A study was conducted to see the variations in the pattern of drainage of posterior segment of the right lobe of liver. The aim was to see the variations of right hepatic vein and small accessory hepatic veins draining the posterior segment, the presence of which led to modifications in drainage of posterior segment. Sixty formalin fixed adult human liver specimens were dissected manually. According to the pattern of drainage of tributaries of right hepatic vein, the right hepatic vein was classified into type I, type II, type III and type IV. According to presence of inferior right hepatic vein, three types of drainage of posterior lobe were seen: Type I, (76.36%) right hepatic vein was large, draining wide area of posterior segment. A small inferior right hepatic vein drained the small area of posterior segment. In Type II, (19.92%) both right hepatic and inferior right hepatic veins were medium sized draining the posteroinferior segment of the right lobe concomitantly. In Type III, (32%) accessory veins, the middle right hepatic vein drained the posterosuperior (VII) as well as the posteroinferior (VI) segment. In one specimen, there were numerous middle right hepatic veins draining the right posterior segment. The knowledge of anatomic relationship of veins draining right lobe, is important in performing right posterior segmentectomy. For safe resection of the liver, the complex anatomy of the distribution of the tributaries of the right hepatic vein and the accessory veins have to be studied prior to any surgery done on liver.

  11. Investigation of the novel attributes in double recessed gate SiC MESFETs at drain side

    NASA Astrophysics Data System (ADS)

    Orouji, Ali A.; Razavi, S. M.; Ebrahim Hosseini, Seyed; Amini Moghadam, Hamid

    2011-11-01

    In this paper, the potential impact of drain side-double recessed gate (DS-DRG) on silicon carbide (SiC)-based metal semiconductor field effect transistors (MESFETs) is studied. We investigate the device performance focusing on breakdown voltage, threshold voltage, drain current and dc output conductance with two-dimensional and two-carrier device simulation. Our simulation results demonstrate that the channel thickness under the gate in the drain side is an important factor in the breakdown voltage. Also, the positive shift in the threshold voltage for the DS-DRG structure is larger in comparison with that for the source side-double recessed gate (SS-DRG) SiC MESFET. The saturated drain current for the DS-DRG structure is larger compared to that for the SS-DRG structure. The maximum dc output conductance in the DS-DRG structure is smaller than that in the SS-DRG structure.

  12. Hydraulic characteristics of an underdrained irrigation circle, Muskegon County wastewater disposal system, Michigan

    USGS Publications Warehouse

    McDonald, M.G.

    1980-01-01

    Muskegon County, Michigan, disposes of wastewater by spray irrigating farmland on its waste-disposal site. Buried drains in the highly permeable unconfined aquifer at the site control the level of the water table. Hydraulic conductivity of the aquifer and drain-leakance, the reciprocal of resistance to flow into the drains, was determined at a representative irrigation circle while calibrating a model of the groundwater flow system. Hydraulic conductivity is 0.00055 m/sec, in the north zone of the circle, and 0.00039 m/sec in the south zone. Drain leakance -6 -6 is low in both zones: 2.9 x 10m/sec in the north and 9.5 x 10 m/sec in the south. Low drain leakance is responsible for waterlogging when irrigation rates are maintained at design levels. The capacity of the study circle to accept wastewater is 35 percent less than design capacity.

  13. Accounting for the risks of phosphorus losses through tile drains in a phosphorus index.

    PubMed

    Reid, D Keith; Ball, Bonnie; Zhang, T Q

    2012-01-01

    Tile drainage systems have been identified as a significant conduit for phosphorus (P) losses to surface water, but P indices do not currently account for this transport pathway in a meaningful way. Several P indices mention tile drains, but most account for either the reduction in surface runoff or the enhanced transport through tiles rather than both simultaneously. A summary of the current state of how tile drains are accounted for within P indices is provided, and the challenges in predicting the risk of P losses through tile drains that are relative to actual losses are discussed. A framework for a component P Index is described, along with a proposal to incorporate predictions of losses through tile drains as a component within this framework. Options for calibrating and testing this component are discussed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  14. Modeling the long-term effect of winter cover crops on nitrate transport in artificially drained fields across the Midwest U.S.

    USDA-ARS?s Scientific Manuscript database

    A fall-planted cover crop is a management practice with multiple benefits including reducing nitrate losses from artificially drained fields. We used the Root Zone Water Quality Model (RZWQM) to simulate the impact of a cereal rye cover crop on reducing nitrate losses from drained fields across five...

  15. Teacher Drain from China's Higher Education Institutions and Some Consequences of This Drain

    ERIC Educational Resources Information Center

    Shufeng, Xu; Shihua, Cui; Zhaoping, Sun; Xianlei, Zhang

    2005-01-01

    Teachers are where the major strength of organizational control lies in the educational process; it is mainly they who restrict the quality of education and teaching and who are the irreplaceable factor in determining how well a school is run and its overall image. Therefore, once a teacher drain from higher education institutions begins, it is…

  16. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...

  17. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...

  18. 76 FR 62605 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-11

    ... the VGB Act defines an ``unblockable drain'' as ``a drain of any size and shape that a human body...'' as follows: A suction outlet defined as all components, including the sump and/or body, cover/grate...'' Body Blocking Element of ASME/ANSI A112.19.8-2007 and that the rated flow through the remaining open...

  19. The Brain Rotation and Brain Diffusion Strategies of Small Islanders: Considering "Movement" in Lieu of "Place"

    ERIC Educational Resources Information Center

    Baldacchino, Godfrey

    2006-01-01

    The "brain drain" phenomenon is typically seen as a zero-sum game, where one party's gain is presumed to be another's drain. This corresponds to deep-seated assumptions about what is "home" and what is "away". This article challenges the view, driven by much "brain drain" literature, that the dynamic is an…

  20. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.

    2014-01-20

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

  1. Method of burning sulfur-containing fuels in a fluidized bed boiler

    DOEpatents

    Jones, Brian C.

    1982-01-01

    A method of burning a sulfur-containing fuel in a fluidized bed of sulfur oxide sorbent wherein the overall utilization of sulfur oxide sorbent is increased by comminuting the bed drain solids to a smaller average particle size, preferably on the order of 50 microns, and reinjecting the comminuted bed drain solids into the bed. In comminuting the bed drain solids, particles of spent sulfur sorbent contained therein are fractured thereby exposing unreacted sorbent surface. Upon reinjecting the comminuted bed drain solids into the bed, the newly-exposed unreacted sorbent surface is available for sulfur oxide sorption, thereby increasing overall sorbent utilization.

  2. Capacitorless one-transistor dynamic random-access memory based on asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor with n-doped boosting layer and drain-underlap structure

    NASA Astrophysics Data System (ADS)

    Yoon, Young Jun; Seo, Jae Hwa; Kang, In Man

    2018-04-01

    In this work, we present a capacitorless one-transistor dynamic random-access memory (1T-DRAM) based on an asymmetric double-gate Ge/GaAs-heterojunction tunneling field-effect transistor (TFET) for DRAM applications. The n-doped boosting layer and gate2 drain-underlap structure is employed in the device to obtain an excellent 1T-DRAM performance. The n-doped layer inserted between the source and channel regions improves the sensing margin because of a high rate of increase in the band-to-band tunneling (BTBT) probability. Furthermore, because the gate2 drain-underlap structure reduces the recombination rate that occurs between the gate2 and drain regions, a device with a gate2 drain-underlap length (L G2_D-underlap) of 10 nm exhibited a longer retention performance. As a result, by applying the n-doped layer and gate2 drain-underlap structure, the proposed device exhibited not only a high sensing margin of 1.11 µA/µm but also a long retention time of greater than 100 ms at a temperature of 358 K (85 °C).

  3. Improvement in the performance of graphene nanoribbon p-i-n tunneling field effect transistors by applying lightly doped profile on drain region

    NASA Astrophysics Data System (ADS)

    Naderi, Ali

    2017-12-01

    In this paper, an efficient structure with lightly doped drain region is proposed for p-i-n graphene nanoribbon field effect transistors (LD-PIN-GNRFET). Self-consistent solution of Poisson and Schrödinger equation within Nonequilibrium Green’s function (NEGF) formalism has been employed to simulate the quantum transport of the devices. In proposed structure, source region is doped by constant doping density, channel is an intrinsic GNR, and drain region contains two parts with lightly and heavily doped doping distributions. The important challenge in tunneling devices is obtaining higher current ratio. Our simulations demonstrate that LD-PIN-GNRFET is a steep slope device which not only reduces the leakage current and current ratio but also enhances delay, power delay product, and cutoff frequency in comparison with conventional PIN GNRFETs with uniform distribution of impurity and with linear doping profile in drain region. Also, the device is able to operate in higher drain-source voltages due to the effectively reduced electric field at drain side. Briefly, the proposed structure can be considered as a more reliable device for low standby-power logic applications operating at higher voltages and upper cutoff frequencies.

  4. Translating evidence-based protocol of wound drain management for total joint arthroplasty into practice: A quasi-experimental study.

    PubMed

    Tsang, Lap Fung; Cheng, Hang Cheong; Ho, Hon Shuen; Hsu, Yung Chak; Chow, Chiu Man; Law, Heung Wah; Fong, Lup Chau; Leung, Lok Ming; Kong, Ivy Ching Yan; Chan, Chi Wai; Sham, Alice So Yuen

    2016-05-01

    Although various drains have long been used in total joint replacement, evidence suggests inconsistent practice exists in the use of drainage systems including intermittently applying suction or free of drainage suction, and variations in the optimal timing for wound drain removal. A comprehensive systematic review of available evidence up to 2013 was conducted in a previous study and a protocol was adapted for clinical application according to the summary of the retrieved information (Tsang, 2015). To determine if the protocol could reduce blood loss and blood transfusion after operation and to develop a record form so as to enhance communication of drainage record amongst surgeons and nurses. A quasi-experimental time-series design was undertaken. In the conventional group, surgeons ordered free drainage if the drain output was more than 300 ml. The time of removal of the drain was based on their professional judgement. In the protocol group the method of drainage was dependant of the drainage output as was the timing of the removal of the drain. A standardized record form was developed to guide operating room and orthopaedic ward nurses to manage the drainage system. The drain was removed significantly earlier in the protocol group. Blood loss rate at the first hour of post-operation was extremely low in the protocol group due to clamping effect. Blood loss in volume during the first three hours in the protocol group was significantly lower than that in the conventional group. Only in 11.1% and 4% of cases was it necessary to clamp at the three and four hour post-operative hours. No clamping was required at the two and eight hour postoperative period. There was no significant difference in blood loss during the removal of the drain and during blood transfusion, which was required for patients upon removal of the drain in the two groups. This is the first clinical study to develop an evidence-based protocol to manage wound drain effectively in Hong Kong. Total blood loss and blood transfusions were not significantly different between the conventional and protocol groups. A standard documentation document is beneficial to enhance communication between doctors and nurses as well as to monitor and observe drainage effectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Potential depletion of surface water in the Colorado River and agricultural drains by groundwater pumping in the Parker-Palo Verde-Cibola area, Arizona and California

    USGS Publications Warehouse

    Leake, Stanley A.; Owen-Joyce, Sandra J.; Heilman, Julian A.

    2013-01-01

    Water use along the lower Colorado River is allocated as “consumptive use,” which is defined to be the amount of water diverted from the river minus the amount that returns to the river. Diversions of water from the river include surface water in canals and water removed from the river by pumping wells in the aquifer connected to the river. A complication in accounting for water pumped by wells occurs if the pumping depletes water in drains and reduces measured return flow in those drains. In that case, consumptive use of water pumped by the wells is accounted for in the reduction of measured return flow. A method is needed to understand where groundwater pumping will deplete water in the river and where it will deplete water in drains. To provide a basis for future accounting for pumped groundwater in the Parker-Palo Verde-Cibola area, a superposition model was constructed. The model consists of three layers of finite-difference cells that cover most of the aquifer in the study area. The model was run repeatedly with each run having a pumping well in a different model cell. The source of pumped water that is depletion of the river, expressed as a fraction of the pumping rate, was computed for all active cells in model layer 1, and maps were constructed to understand where groundwater pumping depletes the river and where it depletes drains. The model results indicate that if one or more drains exist between a pumping well location and the river, nearly all of the depletion will be from drains, and little or no depletion will come from the Colorado River. Results also show that if a well pumps on a side of the river with no drains in the immediate area, depletion will come from the Colorado River. Finally, if a well pumps between the river and drains that parallel the river, a fraction of the pumping will come from the river and the rest will come from the drains. Model results presented in this report may be considered in development or refinement of strategies for accounting for groundwater pumping in the river aquifer connected to the Colorado River in the study area.

  6. Groundwater hydrology and estimation of horizontal groundwater flux from the Rio Grande at selected locations in Albuquerque, New Mexico, 2009–10

    USGS Publications Warehouse

    Rankin, Dale R.; Oelsner, Gretchen P.; McCoy, Kurt J.; Goeff J.M. Moret,; Jeffery A. Worthington,; Kimberly M. Bandy-Baldwin,

    2016-03-17

    The Albuquerque area of New Mexico has two principal sources of water: (1) groundwater from the Santa Fe Group aquifer system, and (2) surface water from the Rio Grande. From 1960 to 2002, pumping from the Santa Fe Group aquifer system caused groundwater levels to decline more than 120 feet while water-level declines along the Rio Grande in Albuquerque were generally less than 40 feet. These differences in water-level declines in the Albuquerque area have resulted in a great deal of interest in quantifying the river-aquifer interaction associated with the Rio Grande.In 2003, the U.S. Geological Survey, in cooperation with the Bureau of Reclamation, acting as fiscal agent for the Middle Rio Grande Endangered Species Collaborative Program, and the U.S. Army Corps of Engineers, began a study to characterize the hydrogeology of the Rio Grande inner valley alluvial aquifer in the Albuquerque area of New Mexico. The study provides hydrologic data in order to enhance the understanding of rates of water leakage from the Rio Grande to the alluvial aquifer, groundwater flow through the aquifer, and discharge of water from the aquifer to riverside drains. The study area extends about 20 miles along the Rio Grande in the Albuquerque area. Piezometers and surface-water gages were installed in paired transects at eight locations. Nested piezometers, completed at various depths in the alluvial aquifer, and surface-water gages, installed in the Rio Grande and riverside drains, were instrumented with pressure transducers. Water-level and water-temperature data were collected from 2009 to 2010.Water levels from the piezometers indicated that groundwater movement was usually away from the river towards the riverside drains. Annual mean horizontal groundwater gradients in the inner valley alluvial aquifer ranged from 0.0024 (I-25 East) to 0.0144 (Pajarito East). The median hydraulic conductivity values of the inner valley alluvial aquifer, determined from slug tests, ranged from 30 feet per day (ft/d) (Montaño) to 120 ft/d (Central) for paired transects, with a median hydraulic conductivity for all transects of 50 ft/d. Daily mean groundwater fluxes from the river through the inner valley alluvial aquifer computed using Darcy’s Law and the slug test results ranged from about 0.01 ft/d (Montaño West) to between 1.0 and 2.0 ft/d (Central East). Median annual groundwater fluxes from the river through the inner valley alluvial aquifer determined using the Suzuki-Stallman method was greatest at Alameda East (0.50 ft/d) and lowest at Alameda West (0.25 ft/d). The results from both methods agreed reasonably well.Seepage investigations conducted by measuring discharge in the east and west riverside drains provided information for computing changes in flow within the drains and for evaluating results from Darcy’s Law and Suzuki-Stallman method flux calculations. Discharge measured in the east riverside drain between the Barelas Bridge and the I-25 bridge indicated that the flow in the east riverside drain increased by an average of 56.5 cubic feet per day per linear foot (ft3/d/ft) of drain. Discharge measured in the west riverside drain between the Central bridge and the I-25 bridge indicated that flow increased between west drain miles 0 and 4, an average of 53.8 ft3/d/ft of drain, and that flow increased between west drain miles 7 and 10, an average of 44.9 ft3/d/ft of drain. In comparison to the seepage measurement results, the groundwater fluxes from the river through the inner valley alluvial aquifer calculated from Darcy’s Law (qslug) and by the Suzuki-Stallman method (qheat) would account for 20–36 percent or 53–95 percent, respectively, of the total flow in the east riverside drain and 22–31 percent or 19–26 percent, respectively, of the total flow in the west drain. These results indicate that the drains likely also receive water from outside the inner valley.The spatial variability of horizontal hydraulic gradients and groundwater fluxes can be primarily attributed to variability in the distances between the river and riverside drains throughout the study area and geologic heterogeneities in the alluvial aquifer. Temporal variability in the water levels, which control the horizontal hydraulic gradients and fluxes between the Rio Grande and the riverside drains, can be primarily attributed to seasonal fluctuations in river stage and irrigation practices.

  7. Wound drains following thyroid surgery.

    PubMed

    Samraj, K; Gurusamy, K S

    2007-10-17

    The nature and indications for thyroid surgery vary and a perceived risk of haemorrhage post-surgery is one reason why wound drains are frequently inserted. However when a significant bleed occurs, wound drains may become blocked and the drain does not obviate the need for surgery or meticulous haemostasis. The evidence in support of the use of drains post-thyroid surgery is unclear therefore and a systematic review of the best available evidence was undertaken. To determine the effects of inserting a wound drain during thyroid surgery, on wound complications, respiratory complications and mortality. We searched the following databases: Cochrane Wounds Group Specialised Register and the Cochrane Central Register of Controlled Trials (CENTRAL) (issue 1, 2007); MEDLINE (2005 to February 2007); EMBASE (2005 to February 2007); CINAHL (2005 to February 2007) using relevant search strategies. Only randomised controlled trials were eligible for inclusion. Quasi randomised studies were excluded. Studies with participants undergoing any form of thyroid surgery, irrespective of indications, were eligible for inclusion in this review. Studies involving people undergoing parathyroid surgery and lateral neck dissections were excluded. At least 80% follow up (till discharge) was considered essential. Studies were assessed for eligibility and data were extracted by two authors independently, differences were resolved by discussion. Studies were assessed for validity including criteria on whether they used a robust method of random sequence generation and allocation concealment. Missing and unclear data were resolved by contacting the study authors. 13 eligible studies were identified (1646 participants). 11 studies compared drainage with no drainage and found no significant difference in re-operation rates; incidence of respiratory distress and wound infections. Post-operative wound collections needing aspiration or drainage were significantly reduced by drains (RR 0.51, 95% CI 0.27 to 0.97), but a further analysis of the 4 high quality studies showed no significant difference (RR 1.82, 95% CI 0.51 to 6.46). Hospital stay was significantly prolonged in the drain group (WMD 1.18 days, 95% CI 0.73 to 1.63).Eleven studies compared suction drain with no drainage and found no significant difference in re-operation rates; incidence of respiratory distress and wound infection rates. The incidence of collections that required aspiration or drainage without formal re-operation was significantly less in the drained group (RR 0.48, 95% CI 0.25 to 0.92). However, further analysis of only high quality studies showed no significant difference (RR 1.78, 95% CI 0.44 to 7.17). Hospital stay was significantly prolonged in the drain group (WMD 1.20 days, 95% CI 0.77 to 1.63). One study compared open drain with no drain. No participant in either group required re-operation. No data were available regarding the incidence of respiratory distress, wound infection and pain. The incidence of collections needing aspiration or drainage without re-operation was not significantly different between the groups and there was no significant difference in length of hospital stay. One study compared suction drainage with passive closed drainage. None of the participants in the study needed re-operation and data regarding other outcomes were not available. Two studies (180 participants) compared open drainage with suction drainage. One study reported wound infections and minor wound collections, both were not significantly different. The other study reported wound collections requiring intervention and hospital stay; both were not significantly different. None of the participants in either study required re-operation. Data regarding other outcomes were not available. There is no clear evidence that using drains in patients undergoing thyroid operations significantly improves patient outcomes and drains may be associated with an increased length of hospital stay. The existing evidence is from trials involving patients having goitres without mediastinal extension, normal coagulation indices and the operation not involving any lateral neck dissection for lymphadenectomy.

  8. Enhancement of AlGaN/GaN high-electron mobility transistor off-state drain breakdown voltage via backside proton irradiation

    NASA Astrophysics Data System (ADS)

    Ren, F.; Hwang, Y.-H.; Pearton, S. J.; Patrick, Erin; Law, Mark E.

    2015-03-01

    Proton irradiation from the backside of the samples were employed to enhance off-state drain breakdown voltage of AlGaN/GaN high electron mobility transistors (HEMTs) grown on Si substrates. Via holes were fabricated directly under the active area of the HEMTs by etching through the Si substrate for subsequent backside proton irradiation. By taking the advantage of the steep drop at the end of proton energy loss profile, the defects created by the proton irradiation from the backside of the sample could be precisely placed at specific locations inside the AlGaN/GaN HEMT structure. There were no degradation of drain current nor enhancement of off-state drain voltage breakdown voltage observed for the irradiated AlGaN/GaN HEMTs with the proton energy of 225 or 275 keV, for which the defects created by the proton irradiations were intentionally placed in the GaN buffer. HEMTs with defects placed in the 2 dimensional electron gas (2DEG) channel region and AlGaN barrier using 330 or 340 keV protons not only showed degradation of drain current, but also exhibited improvement of the off-state drain breakdown voltage. FLOODS TCAD finite-element simulations were performed to confirm the hypothesis of a virtual gate formed around the 2DEG region to reduce the peak electric field around the gate edges and increase the off-state drain breakdown voltage.

  9. Intracerebral hemorrhage after external ventricular drain placement: an evaluation of risk factors for post-procedural hemorrhagic complications.

    PubMed

    Rowe, A Shaun; Rinehart, Derrick R; Lezatte, Stephanie; Langdon, J Russell

    2018-03-07

    The objective of this study was to evaluate and identify the risk factors for developing a new or enlarged intracranial hemorrhage (ICH) after the placement of an external ventricular drain. A single center, nested case-control study of individuals who received an external ventricular drain from June 1, 2011 to June 30, 2014 was conducted at a large academic medical center. A bivariate analysis was conducted to compare those individuals who experienced a post-procedural intracranial hemorrhage to those who did not experience a new bleed. The variables identified as having a p-value less than 0.15 in the bivariate analysis were then evaluated using a multivariate logistic regression model. Twenty-seven of the eighty-one study participants experienced a new or enlarged intracranial hemorrhage after the placement of an external ventricular drain. Of these twenty-seven patients, 6 individuals received an antiplatelet within ninety-six hours of external ventricular drain placement (p = 0.024). The multivariate logistic regression model identified antiplatelet use within 96 h of external ventricular drain insertion as an independent risk factor for post-EVD ICH (OR 13.1; 95% CI 1.95-88.6; p = 0.008). Compared to those study participants who did not receive an antiplatelet within 96 h of external ventricular drain placement, those participants who did receive an antiplatelet were 13.1 times more likely to exhibit a new or enlarged intracranial hemorrhage.

  10. The Nelaton Catheter Guard for Safe and Effective Placement of Subdural Drain for Two-Burr-Hole Trephination in Chronic Subdural Hematoma: A Technical Note.

    PubMed

    Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning

    2015-09-01

    For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.

  11. Acetic acid as a decontamination method for sink drains in a nosocomial outbreak of metallo-β-lactamase-producing Pseudomonas aeruginosa.

    PubMed

    Stjärne Aspelund, A; Sjöström, K; Olsson Liljequist, B; Mörgelin, M; Melander, E; Påhlman, L I

    2016-09-01

    Pseudomonas aeruginosa may colonize water systems via biofilm formation. In hospital environments, contaminated sinks have been associated with nosocomial transmission. Here we describe a prolonged outbreak of a metallo-β-lactamase-producing P. aeruginosa (Pae-MBL) associated with sink drains, and propose a previously unreported decontamination method with acetic acid. To describe a nosocomial outbreak of Pae-MBL associated with hospital sink drains and to evaluate acetic acid as a decontamination method. The outbreak was investigated by searching the microbiology database, microbiological sampling and strain typing. Antibacterial and antibiofilm properties of acetic acid were evaluated in vitro. Pae-MBL-positive sinks were treated with 24% acetic acid once weekly and monitored with repeated cultures. Fourteen patients with positive cultures for Pae-MBL were identified from 2008 to 2014. The patients had been admitted to three wards, where screening discovered Pae-MBL in 12 sink drains located in the patient bathrooms. Typing of clinical and sink drain isolates revealed identical or closely related strains. Pae-MBL biofilm was highly sensitive to acetic acid with a minimum biofilm eradication concentration of 0.75% (range: 0.19-1.5). Weekly treatment of colonized sink drains with acetic acid resulted in negative cultures and terminated transmission. Acetic acid is highly effective against Pae-MBL biofilms, and may be used as a simple method to decontaminate sink drains and to prevent nosocomial transmission. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Transport of agrichemicals to ground and surface water in a small central Indiana watershed

    USGS Publications Warehouse

    Fenelon, J.M.; Moore, R.C.

    1998-01-01

    The occurrence, distribution, concentrations, and pathways of agrichemicals in water were investigated in the Sugar Creek watershed, a poorly drained agricultural watershed typical of many watersheds in the midwestern USA. Water samples from Sugar Creek, two tile drains, and 11 wells along a groundwater flowpath to Sugar Creek were collected between May 1992 and August 1996 and analyzed for N and pesticide compounds. Nitrate was the principal N species and pesticides were common in alluvial water-bearing units in the Sugar Creek floodplain. In the confined stratified drift aquifers, ammonia was the principal N species and pesticides were rare. Tile drains directly affected the water quality in Sugar Creek by transporting Soil pore water and shallow groundwater containing high concentrations of nitrate (NO3) and pesticides to the creek. When tile drains were flowing (typically December through July), elevated NO3 concentrations (2-10 mg/L NO3N) in the creek correlated with high NO3 concentrations (2-23 mg/L NO3N) in tile drains discharging to the creek. Likewise, with concentrations of atrazine and atrazine metabolites, seasonal trends in the tile-drain effluent were similar to seasonal trends in Sugar Creek. When tile drains went dry, NO3 concentrations in the creek were low, indicating most groundwater discharge to the creek consisted of old or denitrified water. Trace levels of pesticides in the creek at low flow probably were the result of seepage from alluvial water-bearing units.

  13. Conservation of peat soils in agricultural use by infiltration of ditch water via submerged drains: results of a case study in the western peat soil area of The Netherlands

    NASA Astrophysics Data System (ADS)

    van den Akker, Jan J. H.; Hendriks, Rob F. A.

    2017-04-01

    About 8% of all soils in The Netherlands are peat soils which almost all drained with ditches and mainly in agricultural use as permanent pasture for dairy farming. The largest part of the peat meadow area is situated in the densely populated western provinces South- and North-Holland and Utrecht and is called the Green Heart and is valued as a historic open landscape. Conservation of these peats soil by raising water levels and converting the peat meadow areas mainly in very extensive grasslands or wet nature proved to be a very costly and slow process due to the strong opposition of farmers and many others who value the open cultural historic landscape and meadow birds. The use of submerged drains seems to be a promising solution acceptable for dairy farmers and effective in diminishing peat oxidation and so the associated subsidence and CO2 emissions. Oxidation of peat soils strongly depends on the depth of groundwater levels in dry periods. In dry periods the groundwater level can be 30 to 50 cm lower than the ditchwater level, which is 30 - 60 cm below soil surface. Infiltration of ditchwater via submerged drain can raise the groundwater level up to the ditchwater level and diminish the oxidation and associated subsidence and CO2 emissions with at least 50%. Since 2003 several pilots with submerged drains are started to check this theoretical reduction and to answer questions raised about water usage and water quality and grass yields and trafficability etcetera. In our presentation we focus on the results of a pilot in South-Holland concerning the hydrological aspects, however, include results from the other pilots to consider the long term aspects such as the reduction of subsidence. The use of submerged drains proves to be promising to reduce peat oxidation and so subsidence and CO2 emissions with at least 50%. Grass yields are more or less equal in parcels with versus parcels without submerged drains. Trafficability in wet periods is better and trampling less by the draining effect of submerged drains. This reduces losses of grass yield by trampling and increases the length of the grazing season. The use of submerged drains causes a higher water usage, however, raising ditchwater levels to derive the same peat soil conservation would require a higher amount of inlet water. The impact on ditchwater quality is in most cases positive, however, sometimes slightly negative. For the dairy farmer submerged drains are economically in the short term not effective, however in the longer term increasingly positive. For the society as a whole the use of submerged drains is a very cost effective way to reduce CO2 emissions and subsidence of peat soils in agricultural use.

  14. Effects of Orifice-Weir Outlet on Hydrology and Water Quality of a Drained Forested Watershed

    Treesearch

    Devendra M. Amatya; R. Wayne Skaggs; J.W. Gilliam; J.H. Hughes

    2003-01-01

    Orifice-weir structures at ditch outlets are proposed to reduce peak drainage rates during high flows and to store water during the growing season in poorly drained managed pine plantations. Two coastal watersheds, one conventionally drained (D1) and another with an orifice-weir outlet (D3), were monitored to examine the effects of this orifice treatment on drainage...

  15. Foliar nutrient concentrations in balsam fir as affected by soil drainage and methods of slash disposal

    Treesearch

    Miroslaw M. Czapowskyj

    1979-01-01

    Foliar nutrient concentrations in young balsam fir growing on strip clearcuts were assessed in relation to soil drainage and three methods of slash disposal. Concentrations of N, K, and Mn were higher for trees growing on well-drained soils than for trees growing on poorly drained soils. Mo concentrations were higher on poorly drained soils and all other measured...

  16. Land-Based Dlischarge Environmental Assessment at Beale Air Force Base, California

    DTIC Science & Technology

    2009-09-01

    Attainment Designations ................. 3-3 3-3 Federally Listed Species Evaluated...drain pit includes special design features to ensure that drained effluent does not enter Hutchinson Creek. The drain pit would consist of a pipe with...The cattle fence would consist of metal T- posts , five-strand cattle wire, and a standard cattle gate with wooden posts . The wooden posts would be

  17. Shallow Groundwater Discharge into Urban Drains: Identifying the Missing Link to Define Urban Typologies for Impact Assessment of Urbanization on Water and Nutrient Balances

    NASA Astrophysics Data System (ADS)

    Ocampo, C. J.; Oldham, C. E.

    2015-12-01

    Groundwater and surface water (GW-SW) interaction in drains of many sandy coastal plain areas displays an ephemeral hydrological regime, as often shifts occur in their hydraulic functioning from a losing to a gaining water conditions upon the position of the surrounding shallow water table (SWT). Urbanization in such areas and stormwater management strategies enhancing infiltration have the potential to alter the infiltration rates and the subsurface water storage dynamics with consequences for the residence time of the water and nutrient transformations prior their discharge into receiving SW drains. Identifying first order control on the above processes will assist the improvement of assessment tools for better urban development. This work presents findings on the hydrodynamics of the GW-SW water exchange in two drains of the Perth Coastal Plain area (Western Australia, Australia) impacted by a SWT developing on a layered variable texture soil: a peri-urban drain and a restored living stream drain in urban residential area. A multi-technique approach was used to investigate water mass balance and fluxes over a reach scale and involved continuous records of hydrometric data for GW-SW interactions, passive tracers for water pathway identification, pore water temperature for vertical water exchange, and differential SW discharge using an Acoustic Doppler Current Profiler. Results highlighted differences in the GW-SW interactions between both drains under stormflow and baseflow conditions. A substantial increase of GW discharge into the drain coincided with the full development of a SWT over a seasonal scale at the peri-urban drain, which suggests a more natural water infiltration and redistribution in the subsurface. In contrast, a large volume of infiltrated rain water was discharged into the living stream over a period of few weeks regardless of the development of the surrounding SWT, which suggests the influence of underground pipe system in water redistribution. The results contributed to identify key physical parameters to define urban typologies, quantify the subsurface storage discharge and residence time, and finally assess the transport and transformations of nutrients using a generalised Damköhler number. Future work will populate the framework with other study cases.

  18. Ionic composition and nitrate in drainage water from fields fertilized with different nitrogen sources, middle swamp watershed, North Carolina, August 2000-August 2001

    USGS Publications Warehouse

    Harden, Stephen L.; Spruill, Timothy B.

    2004-01-01

    A study was conducted from August 2000 to August 2001 to characterize the influence of fertilizer use from different nitrogen sources on the quality of drainage water from 11 subsurface tile drains and 7 surface field ditches in a North Carolina Coastal Plain watershed. Agricultural fields receiving commercial fertilizer (conventional sites), swine lagoon effluent (spray sites), and wastewater-treatment plant sludge (sludge site) in the Middle Swamp watershed were investigated. The ionic composition of drainage water in tile drains and ditches varied depending on fertilizer source type. The dominant ions identified in water samples from tile drains and ditches include calcium, magnesium, sodium, chloride, nitrate, and sulfate, with tile drains generally having lower pH, low or no bicarbonates, and higher nitrate and chloride concentrations. Based on fertilizer source type, median nitrate-nitrogen concentrations were significantly higher at spray sites (32.0 milligrams per liter for tiles and 8.2 milligrams per liter for ditches) relative to conventional sites (6.8 milligrams per liter for tiles and 2.7 milligrams per liter for ditches). The median instantaneous nitrate-nitrogen yields also were significantly higher at spray sites (420 grams of nitrogen per hectare per day for tile drains and 15.6 grams of nitrogen per hectare per day for ditches) relative to conventional sites (25 grams of nitrogen per hectare per day for tile drains and 8.1 grams of nitrogen per hectare per day for ditches). The tile drain site where sludge is applied had a median nitrate-nitrogen concentration of 10.5 milligrams per liter and a median instantaneous nitrate-nitrogen yield of 93 grams of nitrogen per hectare per day, which were intermediate to those of the conventional and spray tile drain sites. Results from this study indicate that nitrogen loadings and subsequent edge-of-field nitrate-nitrogen yields through tile drains and ditches were significantly higher at sites receiving applications of swine lagoon effluent compared to sites receiving commercial fertilizer.

  19. Closure Report for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    2012-08-15

    This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 562, Waste Systems, and provides documentation supporting the completed corrective actions and confirmation that closure objectives for CAU 562 were met. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 as amended). CAU 562 consists of the following 13 Corrective Action Sites (CASs), located in Areas 2, 23, and 25 of the Nevadamore » National Security Site: · CAS 02-26-11, Lead Shot · CAS 02-44-02, Paint Spills and French Drain · CAS 02-59-01, Septic System · CAS 02-60-01, Concrete Drain · CAS 02-60-02, French Drain · CAS 02-60-03, Steam Cleaning Drain · CAS 02-60-04, French Drain · CAS 02-60-05, French Drain · CAS 02-60-06, French Drain · CAS 02-60-07, French Drain · CAS 23-60-01, Mud Trap Drain and Outfall · CAS 23-99-06, Grease Trap · CAS 25-60-04, Building 3123 Outfalls Closure activities began in October 2011 and were completed in April 2012. Activities were conducted according to the Corrective Action Plan for CAU 562 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2011). The corrective actions included No Further Action and Clean Closure. Closure activities generated sanitary waste and hazardous waste. Some wastes exceeded land disposal limits and required offsite treatment prior to disposal. Other wastes met land disposal restrictions and were disposed in appropriate onsite or offsite landfills. NNSA/NSO requests the following: · A Notice of Completion from the Nevada Division of Environmental Protection to NNSA/NSO for closure of CAU 562 · The transfer of CAU 562 from Appendix III to Appendix IV, Closed Corrective Action Units, of the FFACO« less

  20. Novel technique of source and drain engineering for dual-material double-gate (DMDG) SOI MOSFETS

    NASA Astrophysics Data System (ADS)

    Yadav, Himanshu; Malviya, Abhishek Kumar; Chauhan, R. K.

    2018-04-01

    The dual-metal dual-gate (DMDG) SOI has been used with Dual Sided Source and Drain Engineered 50nm SOI MOSFET with various high-k gate oxide. It has been scrutinized in this work to enhance its electrical performance. The proposed structure is designed by creating Dual Sided Source and Drain Modification and its characteristics are evaluated on ATLAS device simulator. The consequence of this dual sided assorted doping on source and drain side of the DMDG transistor has better leakage current immunity and heightened ION current with higher ION to IOFF Ratio. Which thereby vesting the proposed device appropriate for low power digital applications.

  1. Frequency dependence and passive drains in fish-eye lenses

    NASA Astrophysics Data System (ADS)

    Quevedo-Teruel, O.; Mitchell-Thomas, R. C.; Hao, Y.

    2012-11-01

    The Maxwell fish eye lens has previously been reported as being capable of the much sought after phenomenon of subwavelength imaging. The inclusion of a drain in this system is considered crucial to the imaging ability, although its role is the topic of much debate. This paper provides a numerical investigation into a practical implementation of a drain in such systems, and analyzes the strong frequency dependence of both the Maxwell fish eye lens and an alternative, the Miñano lens. The imaging capability of these types of lens is questioned, and it is supported by simulations involving various configurations of drain arrays. Finally, a discussion of the near-field and evanescent wave contribution is given.

  2. The application of remote sensing technology to the solution of problems in the management of resources in Indiana

    NASA Technical Reports Server (NTRS)

    Weismiller, R. A. (Principal Investigator); Mroczynski, R. P.

    1977-01-01

    The author has identified the following significant results. The Lydich quadrangle area was successfully classified into seven cover types: (1) trees, (2) poorly drained soil and water, (3) pasture land, (4) well drained brown soil, (5) moderately well drained dark brown soil, (6) moderately drained soil, and (7) medium to poorly drained soil. Measurements of the percent of mapping unit represented by a named soil series range from 44 to 55 percent. If the class identified as vegetation is combined with the named unit, the range increases from 54 to 64 percent. The Xenia mapping unit was the only unit represented by less than 50 percent of the named unit. Results from the intensive tent moth study in Owensburg and Williams were interpreted from 70 mm color infrared and visually transferred to maps. A correction factor was necessary, because the date the sample photography was taken was a month later than the intensive site data (CF x acres defoliated in each level = expanded defoliated acres).

  3. Hydraulic characteristics of an underdrained irrigation circle, Muskegon County, wastewater disposal system, Michigan

    USGS Publications Warehouse

    McDonald, M.G.

    1981-01-01

    Muskegon County, Michigan, disposes of waste water by spray irrigating farmland on its waste-disposal site. Buried drains in the highly permeable unconfined aquifer at the site control the level of the water table. Hydraulic conductivity of the aquifer and drain-leakance, the reciprocal of resistance to flow into the drains, was determined at a representative irrigation circle while calibrating a model of the ground-water flow system. Hydraulic conductivity is 0.00055 meter per second in the north zone of the circle and 0.00039 meter per second in the south zone. Drain leakance is low in both zones: 2.9 x 10-6 meters per second in the north and 9.5 x 10-6 meters per second in the south. Low drain leakance is responsible for waterlogging when irrigation rates are maintained at design levels. The capacity of the study circle to accept waste water is 35 percent less than design capacity.

  4. Establishment and application of the estimation model for pollutant concentrfation in agriculture drain

    NASA Astrophysics Data System (ADS)

    Li, Qiangkun; Hu, Yawei; Jia, Qian; Song, Changji

    2018-02-01

    It is the key point of quantitative research on agricultural non-point source pollution load, the estimation of pollutant concentration in agricultural drain. In the guidance of uncertainty theory, the synthesis of fertilization and irrigation is used as an impulse input to the farmland, meanwhile, the pollutant concentration in agricultural drain is looked as the response process corresponding to the impulse input. The migration and transformation of pollutant in soil is expressed by Inverse Gaussian Probability Density Function. The law of pollutants migration and transformation in soil at crop different growth periods is reflected by adjusting parameters of Inverse Gaussian Distribution. Based on above, the estimation model for pollutant concentration in agricultural drain at field scale was constructed. Taking the of Qing Tong Xia Irrigation District in Ningxia as an example, the concentration of nitrate nitrogen and total phosphorus in agricultural drain was simulated by this model. The results show that the simulated results accorded with measured data approximately and Nash-Sutcliffe coefficients were 0.972 and 0.964, respectively.

  5. Organic Field Effect Transistors for Large Format Electronics

    DTIC Science & Technology

    2003-06-19

    calculated output characteristics for a p-channel substrate insulator Organic layer Source Drain Gate 6 pentacene OFET with 2µm source to drain spacing...conventional transistors. Figure 3. Calculated output characteristics of a pentacene OFET with image charge induced contact barrier...Cross section view of a part of an OFET in the vicinity of a source or drain contact. local ordering due to surface energy effects. The development of

  6. Influence of eastern hemlock (Tsuga canadensis) forests on aquatic invertebrate assemblages in headwater streams

    USGS Publications Warehouse

    Snyder, C.D.; Young, J.A.; Lemarie, D.P.; Smith, D.R.

    2002-01-01

    We conducted a comparative study in the Delaware Water Gap National Recreation Area to determine the potential long-term impacts of hemlock forest decline on stream benthic macroinvertebrate assemblages. Hemlock forests throughout eastern North America have been declining because of the hemlock woolly adelgid, an exotic insect pest. We found aquatic invertebrate community structure to be strongly correlated with forest composition. Streams draining hemlock forests supported significantly more total taxa than streams draining mixed hardwood forests, and over 8% of the taxa were strongly associated with hemlock. In addition, invertebrate taxa were more evenly distributed (i.e., higher Simpson's evenness values) in hemlock-drained streams. In contrast, the number of rare species and total densities were significantly lower in streams draining hemlock, suggesting that diversity differences observed between forest types were not related to stochastic factors associated with sampling and that streams draining mixed hardwood forests may be more productive. Analysis of stream habitat data indicated that streams draining hemlock forests had more stable thermal and hydrologic regimes. Our findings suggest that hemlock decline may result in long-term changes in headwater ecosystems leading to reductions in both within-stream (i.e., alpha) and park-wide (i.e., gamma) benthic community diversity.

  7. Durability of Drainage Improvement by Combination of Main Drain and Trench Drains with Vertical Drains in Clayey Field Converted from Paddy to Upland Use

    NASA Astrophysics Data System (ADS)

    Adachi, Kazuhide; Ohno, Satoshi; Furuhata, Masami; Ogura, Chikara; Tanimoto, Takeshi

    The drainage efficiency of a subsurface drainage system for avoidance of standing water on the plow pan of clayey field was evaluated. A subsurface drainage system with a main drain and orthogonally adjoined rice husk trench drains joined by vertical rice husk drains was constructed on a test plot and compared to an identical control plot of paddy field converted to upland use under soybean cultivation. The ratio of total underdrain discharge to rainfall in the improved plot greatly increased over two years compared to that in a control plot. In the improved plot, the peak underdrain discharge per hour associated with some heavy rainfalls was around 3 mm/h in the first year but decreased to about 2 mm/h in the second year. By improving drainage in the paddy field, standing water on the plow pan was quickly eliminated after rain events and the period of flooding on the plow pan during the soybean growing season was greatly reduced. However, underdrain discharge in the improved plot decreased greatly in the third year to be at the same level as in the control plot, and rain water flooded the plow pan for extended periods of time.

  8. Is a drain tube necessary for minimally invasive lumbar spine fusion surgery?

    PubMed

    Hung, Pei-I; Chang, Ming-Chau; Chou, Po-Hsin; Lin, Hsi-Hsien; Wang, Shih-Tien; Liu, Chien-Lin

    2017-03-01

    This study aimed to evaluate if closed suction wound drainage is necessary in minimally invasive surgery of transforaminal lumbar interbody fusion (MIS TLIF). This is a prospective randomized clinical study. Fifty-six patients who underwent MIS TLIF were randomly divided into groups A (with a closed suction wound drainage) and B (without tube drainage). Surgical duration, intraoperative blood loss, timing of ambulation, length of hospital stay and complications were recorded. Patients were followed up for an average of 25.3 months. Clinical outcome was assessed using the Oswestry disability index and visual analogue scale (VAS). Fusion rate was classified with the Bridwell grading system, based on plain radiograph. Both groups had similar patient demographics. The use of drains had no significant influence on perioperative parameters including operative time, estimated blood loss, length of stay and complications. Patients in group B started ambulation 1 day earlier than patients in group A (p < 0.001). Clinical outcomes were comparable between group A and group B. A drain tube can lead to pain, anxiety and discomfort during the postoperative period. We conclude that drain tubes are not necessary for MIS TLIF. Patients without drains had the benefit of earlier ambulation than those with drains.

  9. Differences in microbial community structure and nitrogen cycling in natural and drained tropical peatland soils.

    PubMed

    Espenberg, Mikk; Truu, Marika; Mander, Ülo; Kasak, Kuno; Nõlvak, Hiie; Ligi, Teele; Oopkaup, Kristjan; Maddison, Martin; Truu, Jaak

    2018-03-16

    Tropical peatlands, which play a crucial role in the maintenance of different ecosystem services, are increasingly drained for agriculture, forestry, peat extraction and human settlement purposes. The present study investigated the differences between natural and drained sites of a tropical peatland in the community structure of soil bacteria and archaea and their potential to perform nitrogen transformation processes. The results indicate significant dissimilarities in the structure of soil bacterial and archaeal communities as well as nirK, nirS, nosZ, nifH and archaeal amoA gene-possessing microbial communities. The reduced denitrification and N 2 -fixing potential was detected in the drained tropical peatland soil. In undisturbed peatland soil, the N 2 O emission was primarily related to nirS-type denitrifiers and dissimilatory nitrate reduction to ammonium, while the conversion of N 2 O to N 2 was controlled by microbes possessing nosZ clade I genes. The denitrifying microbial community of the drained site differed significantly from the natural site community. The main reducers of N 2 O were microbes harbouring nosZ clade II genes in the drained site. Additionally, the importance of DNRA process as one of the controlling mechanisms of N 2 O fluxes in the natural peatlands of the tropics revealed from the results of the study.

  10. Analytical solutions for flow fields near drain-and-gate reactive barriers.

    PubMed

    Klammler, Harald; Hatfield, Kirk; Kacimov, Anvar

    2010-01-01

    Permeable reactive barriers (PRBs) are a popular technology for passive contaminant remediation in aquifers through installation of reactive materials in the pathway of a plume. Of fundamental importance are the degree of remediation inside the reactor (residence time) and the portion of groundwater intercepted by a PRB (capture width). Based on a two-dimensional conformal mapping approach (previously used in related work), the latter is studied in the present work for drain-and-gate (DG) PRBs, which may possess a collector and a distributor drain ("full" configuration) or a collector drain only ("simple" configuration). Inherent assumptions are a homogeneous unbounded aquifer with a uniform far field, in which highly permeable drains establish constant head boundaries. Solutions for aquifer flow fields in terms of the complex potential are derived, illustrated, and analyzed for doubly symmetric DG configurations and arbitrary reactor hydraulic resistance as well as ambient groundwater flow direction. A series of practitioner-friendly charts for capture width is given to assist in PRB design and optimization without requiring complex mathematics. DG PRBs are identified as more susceptible to flow divergence around the reactor than configurations using impermeable side structures (e.g., funnel-and-gate), and deployment of impermeable walls on drains is seen to mitigate this problem under certain circumstances.

  11. Leaching of dissolved phosphorus from tile-drained agricultural areas.

    PubMed

    Andersen, H E; Windolf, J; Kronvang, B

    2016-01-01

    We investigated leaching of dissolved phosphorus (P) from 45 tile-drains representing animal husbandry farms in all regions of Denmark. Leaching of P via tile-drains exhibits a high degree of spatial heterogeneity with a low concentration in the majority of tile-drains and few tile-drains (15% in our investigation) having high to very high concentration of dissolved P. The share of dissolved organic P (DOP) was high (up to 96%). Leaching of DOP has hitherto been a somewhat overlooked P loss pathway in Danish soils and the mechanisms of mobilization and transport of DOP needs more investigation. We found a high correlation between Olsen-P and water extractable P. Water extractable P is regarded as an indicator of risk of loss of dissolved P. Our findings indicate that Olsen-P, which is measured routinely in Danish agricultural soils, may be a useful proxy for the P leaching potential of soils. However, we found no straight-forward correlation between leaching potential of the top soil layer (expressed as either degree of P saturation, Olsen-P or water extractable P) and the measured concentration of dissolved P in the tile-drain. This underlines that not only the source of P but also the P loss pathway must be taken into account when evaluating the risk of P loss.

  12. Does pilonidal abscess heal quicker with off-midline incision and drainage?

    PubMed

    Webb, P M; Wysocki, A P

    2011-06-01

    No clinical trials have been done to guide the surgeon in the optimal technique of draining a pilonidal abscess. The aim of our study was to investigate whether the location of the incision influences wound healing. Electronic records from the surgical database at our 200-bed district general hospital were reviewed for operative technique (midline vs. lateral) for patients who underwent incision and drainage for acute pilonidal abscess between January 2003 and February 2010. These patients were admitted from the Emergency Department with a pilonidal abscess, underwent operative drainage, and returned for follow-up. The main outcome measure was wound healing time. Two hundred and forty-three pilonidal abscesses were drained, 134 with a lateral and 74 with a midline incision. All patients underwent simple longitudinal incision. No patient underwent de-roofing, marsupialisation, or closure. Forty-eight patients with midline drainage who returned for follow-up were matched for gender, age, and microbiology culture results with patients who underwent lateral drainage. Almost all were drained under general anesthesia with a median postoperative stay of 1 day. The overall length of follow-up was the same in both groups (P = 0.13). Abscesses that did not heal were followed-up for the same period of time irrespective of incision type (P = 0.48). Abscesses that healed after midline incision took approximately 3 weeks longer than those drained via a lateral incision (P = 0.02). Our study has limitations since it was a retrospective study that did not capture patients whose abscess drained spontaneously or were drained in the emergency department. Pilonidal abscess should be drained away from the midline.

  13. The hydrology of a drained topographical depression within an agricutlural field in north-central Iowa

    USGS Publications Warehouse

    Roth, Jason L.; Capel, Paul D.

    2012-01-01

    North-central Iowa is an agriculturally intensive area comprising the southeastern portion of the Prairie Pothole Region, a landscape containing a high density of enclosed topographical depressions. Artificial drainage practices have been implemented throughout the area to facilitate agricultural production. Vertical surface drains are utilized to drain the topographical depressions that accumulate water. This study focuses on the hydrology of a drained topographical depression located in a 39.5 ha agricultural field. To assess the hydrology of the drained depression, a water balance was constructed for 11 ponding events during the 2008 growing season. Continuous pond and groundwater level data were obtained with pressure transducers. Flows into the vertical surface drain were calculated based on pond depth. Precipitation inflows and evaporative outflows of the ponds were calculated using climatic data. Groundwater levels were used to assess groundwater/pond interactions. Results of the water balances show distinct differences between the inflows to and outflows from the depression based on antecedent conditions. In wet conditions, groundwater inflow sustained the ponds. The ponds receded only after the groundwater level declined to below the land surface. In drier conditions, groundwater was not a source of water to the depression. During these drier conditions, infiltration comprised 30% of the outflows from the depression during declining pond stages. Over the entire study period, the surface drain, delivering water to the stream, was the largest outflow from the pond, accounting for 97% of the outflow, while evapotranspiration was just 2%. Precipitation onto the pond surface proved to be a minor component, accounting for 4% of the total inflows.

  14. A novel explicit approach to model bromide and pesticide transport in connected soil structures

    NASA Astrophysics Data System (ADS)

    Klaus, J.; Zehe, E.

    2011-07-01

    The present study tests whether an explicit treatment of worm burrows and tile drains as connected structures is feasible for simulating water flow, bromide and pesticide transport in structured heterogeneous soils at hillslope scale. The essence is to represent worm burrows as morphologically connected paths of low flow resistance in a hillslope model. A recent Monte Carlo study (Klaus and Zehe, 2010, Hydrological Processes, 24, p. 1595-1609) revealed that this approach allowed successful reproduction of tile drain event discharge recorded during an irrigation experiment at a tile drained field site. However, several "hillslope architectures" that were all consistent with the available extensive data base allowed a good reproduction of tile drain flow response. Our second objective was thus to find out whether this "equifinality" in spatial model setups may be reduced when including bromide tracer data in the model falsification process. We thus simulated transport of bromide for the 13 spatial model setups that performed best with respect to reproduce tile drain event discharge, without any further calibration. All model setups allowed a very good prediction of the temporal dynamics of cumulated bromide leaching into the tile drain, while only four of them matched the accumulated water balance and accumulated bromide loss into the tile drain. The number of behavioural model architectures could thus be reduced to four. One of those setups was used for simulating transport of Isoproturon, using different parameter combinations to characterise adsorption according to the Footprint data base. Simulations could, however, only reproduce the observed leaching behaviour, when we allowed for retardation coefficients that were very close to one.

  15. Peat accumulation in drained thermokarst lake basins in continuous, ice-rich permafrost, northern Seward Peninsula, Alaska

    USGS Publications Warehouse

    Jones, Miriam C.; Grosse, Guido; Jones, Benjamin M.; Anthony, Katey Walter

    2012-01-01

    Thermokarst lakes and peat-accumulating drained lake basins cover a substantial portion of Arctic lowland landscapes, yet the role of thermokarst lake drainage and ensuing peat formation in landscape-scale carbon (C) budgets remains understudied. Here we use measurements of terrestrial peat thickness, bulk density, organic matter content, and basal radiocarbon age from permafrost cores, soil pits, and exposures in vegetated, drained lake basins to characterize regional lake drainage chronology, C accumulation rates, and the role of thermokarst-lake cycling in carbon dynamics throughout the Holocene on the northern Seward Peninsula, Alaska. Most detectable lake drainage events occurred within the last 4,000 years with the highest drainage frequency during the medieval climate anomaly. Peat accumulation rates were highest in young (50–500 years) drained lake basins (35.2 g C m−2 yr−1) and decreased exponentially with time since drainage to 9 g C m−2 yr−1 in the oldest basins. Spatial analyses of terrestrial peat depth, basal peat radiocarbon ages, basin geomorphology, and satellite-derived land surface properties (Normalized Difference Vegetation Index (NDVI); Minimum Noise Fraction (MNF)) from Landsat satellite data revealed significant relationships between peat thickness and mean basin NDVI or MNF. By upscaling observed relationships, we infer that drained thermokarst lake basins, covering 391 km2 (76%) of the 515 km2 study region, store 6.4–6.6 Tg organic C in drained lake basin terrestrial peat. Peat accumulation in drained lake basins likely serves to offset greenhouse gas release from thermokarst-impacted landscapes and should be incorporated in landscape-scale C budgets.

  16. Multiyear nutrient removal performance of three constructed wetlands intercepting tile drain flows from grazed pastures.

    PubMed

    Tanner, Chris C; Sukias, James P S

    2011-01-01

    Subsurface tile drain flows can be a major s ource of nurient loss from agricultural landscapes. This study quantifies flows and nitrogen and phosphorus yields from tile drains at three intensively grazed dairy pasture sites over 3- to 5-yr periods and evaluates the capacity of constructed wetlands occupying 0.66 to 1.6% of the drained catchments too reduce nutrient loads. Continuous flow records are combined with automated flow-proportional sampling of nutrient concentrations to calculate tile drain nutrient yields and wetland mass removal rates. Annual drainage water yields rangedfrom 193 to 564 mm (16-51% of rainfall) at two rain-fed sites and from 827 to 853 mm (43-51% of rainfall + irrigation) at an irrigated site. Annually, the tile drains exported 14 to 109 kg ha(-1) of total N (TN), of which 58 to 90% was nitrate-N. Constructed wetlands intercepting these flows removed 30 to 369 gTN m(-2) (7-63%) of influent loadings annually. Seasonal percentage nitrate-N and TN removal were negatively associated with wetland N mass loadings. Wetland P removal was poor in all wetlands, with 12 to 115% more total P exported annually overall than received. Annually, the tile drains exported 0.12 to 1.38 kg ha of total P, of which 15 to 93% was dissolved reactive P. Additional measures are required to reduce these losses or provide supplementary P removal. Wetland N removal performance could be improved by modifying drainage systems to release flows more gradually and improving irrigation practices to reduce drainage losses.

  17. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    PubMed

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p < 0.001). There was no significant difference between groups B and C ( p = 0.99). The drainage clamping method can be safer than IA-TXA administration in patients with risk factor of venous thromboembolic complication. Furthermore, the IA-TXA administration can be more optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  18. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rozemeijer, J. C.; Visser, A.; Borren, W.

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates andmore » the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007–2008) and after (2009–2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. Furthermore, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.« less

  19. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    DOE PAGES

    Rozemeijer, J. C.; Visser, A.; Borren, W.; ...

    2016-01-19

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates andmore » the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007–2008) and after (2009–2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. Furthermore, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.« less

  20. Design and performance of limestone drains to increase pH and remove metals from acidic mine drainage, Chapter 2

    USGS Publications Warehouse

    Cravotta,, Charles A.; Watzlaf, George R.

    2002-01-01

    Data on the construction characteristics and the composition of influent and effluent at 13 underground, limestone-filled drains in Pennsylvania and Maryland are reported to evaluate the design and performance of limestone drains for the attenuation of acidity and dissolved metals in acidic mine drainage. On the basis of the initial mass of limestone, dimensions of the drains, and average flow rates, the initial porosity and average detention time for each drain were computed. Calculated porosity ranged from 0.12 to 0.50 with corresponding detention times at average flow from 1.3 to 33 h. The effectiveness of treatment was dependent on influent chemistry, detention time, and limestone purity. At two sites where influent contained elevated dissolved Al (>5 mg/liter), drain performance declined rapidly; elsewhere the drains consistently produced near-neutral effluent, even when influent contained small concentrations of dissolved Fe^+ (<5 mg/liter). Rates of limestone dissolution computed on the basis of average long-term Ca ion flux normalized by initial mass and purity of limestone at each of the drains ranged from 0.008 to 0.079 year-1. Data for alkalinity concentration and flux during 11-day closed-container tests using an initial mass of 4kg crushed limestone and a solution volume of 2.3 liter yielded dissolution rate constants that were comparable to these long-term field rates. An analytical method is proposed using closed-container test data to evaluate long-term performance (longevity) or to estimate the mass of limestone needed for a limestone treatment. This method condisers flow rate, influent alkalinity, steady-state alkalinity of effluent, and desired effluent alkalinity or detention time at a future time(s) and aplies first-order rate laws for limestone dissolution (continuous) and production of alkalinity (bounded).

  1. Characterizing the Frequency and Elevation of Rapid Drainage Events in West Greenland

    NASA Astrophysics Data System (ADS)

    Cooley, S.; Christoffersen, P.

    2016-12-01

    Rapid drainage of supraglacial lakes on the Greenland Ice Sheet is critical for the establishment of surface-to-bed hydrologic connections and the subsequent transfer of water from surface to bed. Yet, estimates of the number and spatial distribution of rapidly draining lakes vary widely due to limitations in the temporal frequency of image collection and obscureness by cloud. So far, no study has assessed the impact of these observation biases. In this study, we examine the frequency and elevation of rapidly draining lakes in central West Greenland, from 68°N to 72.6°N, and we make a robust statistical analysis to estimate more accurately the likelihood of lakes draining rapidly. Using MODIS imagery and a fully automated lake detection method, we map more than 500 supraglacial lakes per year over a 63000 km2 study area from 2000-2015. Through testing four different definitions of rapidly draining lakes from previously published studies, we find that the number of rapidly draining lakes varies from 3% to 38%. Logistic regression between rapid drainage events and image sampling frequency demonstrates that the number of rapid drainage events is strongly dependent on cloud-free observation percentage. We then develop three new drainage criteria and apply an observation bias correction that suggests a true rapid drainage probability between 36% and 45%, considerably higher than previous studies without bias assessment have reported. We find rapid-draining lakes are on average larger and disappear earlier than slow-draining lakes, and we also observe no elevation differences for the lakes detected as rapidly draining. We conclude a) that methodological problems in rapid drainage research caused by observation bias and varying detection methods have obscured large-scale rapid drainage characteristics and b) that the lack of evidence for an elevation limit on rapid drainage suggests surface-to-bed hydrologic connections may continue to propagate inland as climate warms.

  2. High-frequency monitoring of water fluxes and nutrient loads to assess the effects of controlled drainage on water storage and nutrient transport

    NASA Astrophysics Data System (ADS)

    Rozemeijer, J. C.; Visser, A.; Borren, W.; Winegram, M.; van der Velde, Y.; Klein, J.; Broers, H. P.

    2016-01-01

    High nitrogen (N) and phosphorus (P) fluxes from upstream agriculture threaten aquatic ecosystems in surface waters and estuaries, especially in areas characterized by high agricultural N and P inputs and densely drained catchments like the Netherlands. Controlled drainage has been recognized as an effective option to optimize soil moisture conditions for agriculture and to reduce unnecessary losses of fresh water and nutrients. This is achieved by introducing control structures with adjustable overflow levels into subsurface tube drain systems. A small-scale (1 ha) field experiment was designed to investigate the hydrological and chemical changes after introducing controlled drainage. Precipitation rates and the response of water tables and drain fluxes were measured in the periods before the introduction of controlled drainage (2007-2008) and after (2009-2011). For the N and P concentration measurements, auto-analyzers for continuous records were combined with passive samplers for time-averaged concentrations at individual drain outlets. The experimental setup enabled the quantification of changes in the water and solute balance after introducing controlled drainage. The results showed that introducing controlled drainage reduced the drain discharge and increased the groundwater storage in the field. To achieve this, the overflow levels have to be elevated in early spring, before the drain discharge stops due to dryer conditions and falling groundwater levels. The groundwater storage in the field would have been larger if the water levels in the adjacent ditch were controlled as well by an adjustable weir. The N concentrations and loads increased, which was largely related to elevated concentrations in one of the three monitored tube drains. The P loads via the tube drains reduced due to the reduction in discharge after introducing controlled drainage. However, this may be counteracted by the higher groundwater levels and the larger contribution of N- and P-rich shallow groundwater and overland flow to the surface water.

  3. Year 3 Summary Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin

    USGS Publications Warehouse

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2008-01-01

    This report summarizes findings from the third year of a 4-year-long field investigation to document selected baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water quality and fish species were measured at roughly quarterly intervals from April 2007 to January 2008. The water quality measurements included total suspended solids and total (particulate plus dissolved) selenium. In addition, during April and October 2007, water samples were collected from seven intensively monitored drains for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices (particulate organic detritus, filamentous algae, net plankton, and midge [chironomid] larvae), and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for desert pupfish (Cyprinodon macularius), an endangered species that we were not permitted to take for selenium determinations. Water quality values were typical of surface waters in a hot desert climate. A few drains exhibited brackish, near anoxic conditions especially during the summer and fall when water temperatures occasionally exceeded 30 degrees C. In general, total selenium concentrations in water varied directly with conductivity and inversely with pH. Although desert pupfish were found in several drains, sometimes in relatively high numbers, the fish faunas of most drains and ponds were dominated by nonnative species, especially red shiner (Cyprinella lutrensis), mosquitofish, and mollies. Dissolved selenium in water samples from the seven intensively monitored drains ranged from 0.700 to 24.1 ug/L, with selenate as the major constituent in all samples. Selenium concentrations in other matrices varied widely among drains and ponds, with at least one drain (for example, Trifolium 18) exhibiting especially high concentrations in food chain organisms (in detritus, 13.3-28.9 ug Se/g; in net plankton, 11.9-19.3 ug Se/g; in midge larvae, 12.7-15.4 ug Se/g) and fish (in mollies, 12.8-25.1 ug Se/g; in mosquitofish, 13.2-20.2 ug Se/g; all concentrations are dry weights). These elevated concentrations approached or exceeded average concentrations reported from flowing waters in seleniferous wetlands in the San Joaquin Valley.

  4. Final Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin, California

    USGS Publications Warehouse

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2010-01-01

    This report summarizes comprehensive findings from a 4-year-long field investigation to document baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water-quality collections and fish community assessments were conducted on as many as 16 sampling dates at roughly quarterly intervals from July 2005 to April 2009. The water-quality measurements included total suspended solids and total (particulate plus dissolved) selenium. With one exception, fish were surveyed with baited minnow traps at quarterly intervals during the same time period. However, in July 2007, fish surveys were not conducted because we lacked permission from the California Department of Fish and Game for incidental take of desert pupfish (Cyprinodon macularius), an endangered species. During April and October 2006-08, water samples also were collected from seven intensively monitored drains (which were selected from the 29 total drains) for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices [particulate organic detritus, filamentous algae, net plankton, and midge (chironomid) larvae], and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for pupfish, which we were not permitted to sacrifice for selenium determinations. Water quality (temperature, dissolved oxygen, pH, specific conductance, and turbidity) values were typical of surface waters in a hot, arid climate. A few drains exhibited brackish, near-anoxic conditions, especially during summer and fall when water temperatures occasionally exceeded 30 degrees Celsius. Total selenium concentrations in water were directly correlated with salinity and inversely correlated with total suspended-solids concentrations. Although pupfish were found in several drains, sometimes in relatively high numbers, the fish faunas of most drains and ponds were dominated by nonnative species, especially mosquitofish, mollies, and red shiner (Cyprinella lutrensis). Dissolved selenium in water samples from the seven intensively monitored drains ranged from 0.700 to 32.8 micrograms per liter (?g/L), with selenate as the major constituent. Selenium concentrations in other matrices varied widely among drains and ponds, with one drain (Trifolium 18) exhibiting especially high concentrations in food chain matrices [particulate organic detritus, 5.98-58.0 micrograms of selenium per gram (?g Se/g); midge larvae, 12.7-50.6 ?g Se/g] and in fish (mosquitofish, 13.2-20.2 ?g Se/g; sailfin mollies, 12.8-30.4 ?g Se/g; all concentrations are based on dry weights). Although selenium was accumulated by all trophic levels, biomagnification (defined as a progressive increase in selenium concentration from one trophic level to the next higher level) in midge larvae and fish occurred only at lower exposure concentrations. Judging mostly from circumstantial evidence, the health and wellbeing of poeciliids and pupfish are not believed to be threatened by ambient exposure to selenium in the drains and ponds.

  5. Development of a 30mm Frangible Projectile Crimper

    DTIC Science & Technology

    1977-02-01

    located at end of tank. Open drain valve to drain condensation Tht outomatic lank drain equipped compressor makes this unnecessary. PRESSURE SWITCH : The... pressure switch is automatic and will start compressor at the low pressure and stop when the maximum pressure is leached. It is adjusted to start...of the check valve, located between the compressor and the tank, together with the relief valve on pressure switch relief valve units, and the cen

  6. Simulation study of short-channel effects of tunnel field-effect transistors

    NASA Astrophysics Data System (ADS)

    Fukuda, Koichi; Asai, Hidehiro; Hattori, Junichi; Mori, Takahiro; Morita, Yukinori; Mizubayashi, Wataru; Masahara, Meishoku; Migita, Shinji; Ota, Hiroyuki; Endo, Kazuhiro; Matsukawa, Takashi

    2018-04-01

    Short-channel effects of tunnel field-effect transistors (FETs) are investigated in detail using simulations of a nonlocal band-to-band tunneling model. Discussion is limited to silicon. Several simulation scenarios were considered to address different effects, such as source overlap and drain offset effects. Adopting the drain offset to suppress the drain leakage current suppressed the short channel effects. The physical mechanism underlying the short-channel behavior of the tunnel FETs (TFETs) was very different from that of metal-oxide-semiconductor FETs (MOSFETs). The minimal gate lengths that do not lose on-state current by one order are shown to be 3 nm for single-gate structures and 2 nm for double gate structures, as determined from the drain offset structure.

  7. Ultrasound guided transrectal catheter drainage of pelvic collections.

    PubMed

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  8. Top-Contact Pentacene-Based Organic Thin Film Transistor (OTFT) with N, N'-Bis(3-Methyl Phenyl)- N, N'-Diphenyl Benzidine (TPD)/Au Bilayer Source-Drain Electrode

    NASA Astrophysics Data System (ADS)

    Borthakur, Tribeni; Sarma, Ranjit

    2018-01-01

    A top-contact Pentacene-based organic thin film transistor (OTFT) with N, N'-Bis (3-methyl phenyl)- N, N'-diphenyl benzidine (TPD)/Au bilayer source-drain electrode is reported. The devices with TPD/Au bilayer source-drain (S-D) electrodes show better performance than the single layer S-D electrode OTFT devices. The field-effect mobility of 4.13 cm2 v-1 s-1, the on-off ratio of 1.86 × 107, the threshold voltage of -4 v and the subthreshold slope of .27 v/decade, respectively, are obtained from the device with a TPD/Au bilayer source-drain electrode.

  9. Sediment transport by irrigation return flows on the Yakima Indian Reservation, Washington 1975 and 1976 irrigation seasons

    USGS Publications Warehouse

    Nelson, Leonard M.

    1978-01-01

    As determined from data collected at 10 sites on the Yakima Indian Reservation, Wash., during the 1975 and 1976 irrigation seasons (April-September), seasonal sediment discharges in irrigation return flows ranged from 11,000 tons from Marion Drain and Satus Drain 302 to 400 tons from Coulee Drain. There was little variation between the sediment discharges of the 1975 and 1976 irrigation seasons except those from Satus Drain 302. Due to the lack of natural runoff during those seasons, no distinction could be made between sediment discharges from irrigated and nonirrigated areas. No significant or usable relationships were found between suspend-sediment concentration and concurrent water turbidity or discharges. (Woodard-USGS)

  10. Diagnostic value of drain amylase for detecting intrathoracic leakage after esophagectomy

    PubMed Central

    Berkelmans, Gijs HK; Kouwenhoven, Ewout A; Smeets, Boudewijn JJ; Weijs, Teus J; Silva Corten, Luis C; van Det, Marc J; Nieuwenhuijzen, Grard AP; Luyer, Misha DP

    2015-01-01

    AIM: To investigate the value of elevated drain amylase concentrations for detecting anastomotic leakage (AL) after minimally invasive Ivor-Lewis esophagectomy (MI-ILE). METHODS: This was a retrospective analysis of prospectively collected data in two hospitals in the Netherlands. Consecutive patients undergoing MI-ILE were included. A Jackson-Pratt drain next to the dorsal side of the anastomosis and bilateral chest drains were placed at the end of the thoracoscopic procedure. Amylase levels in drain fluid were determined in all patients during at least the first four postoperative days. Contrast computed tomography scans and/or endoscopic imaging were performed in cases of a clinically suspected AL. Anastomotic leakage was defined as any sign of leakage of the esophago-gastric anastomosis on endoscopy, re-operation, radiographic investigations, post mortal examination or when gastro-intestinal contents were found in drain fluid. Receiver operator characteristic curves were used to determine the cut-off values. Sensitivity, specificity, positive predictive value, negative predictive value, risk ratio and overall test accuracy were calculated for elevated drain amylase concentrations. RESULTS: A total of 89 patients were included between March 2013 and August 2014. No differences in group characteristics were observed between patients with and without AL, except for age. Patients with AL were older than were patients without AL (P = 0.01). One patient (1.1%) without AL died within 30 d after surgery due to pneumonia and acute respiratory distress syndrome. Anastomotic leakage that required any intervention occurred in 15 patients (16.9%). Patients with proven anastomotic leakage had higher drain amylase levels than patients without anastomotic leakage [median 384 IU/L (IQR 34-6263) vs median 37 IU/L (IQR 26-66), P = 0.003]. Optimal cut-off values on postoperative days 1, 2, and 3 were 350 IU/L, 200 IU/L and 160 IU/L, respectively. An elevated amylase level was found in 9 of the 15 patients with AL. Five of these 9 patients had early elevations of their amylase levels, with a median of 2 d (IQR 2-5) before signs and symptoms occurred. CONCLUSION: Measurement of drain amylase levels is an inexpensive and easy tool that may be used to screen for anastomotic leakage soon after MI-ILE. However, clinical validation of this marker is necessary. PMID:26290638

  11. Peritoneal drainage or laparotomy for neonatal bowel perforation? A randomized controlled trial.

    PubMed

    Rees, Clare M; Eaton, Simon; Kiely, Edward M; Wade, Angie M; McHugh, Kieran; Pierro, Agostino

    2008-07-01

    To determine whether primary peritoneal drainage improves survival and outcome of extremely low birth weight (ELBW) infants with intestinal perforation. Optimal surgical management of ELBW infants with intestinal perforation is unknown. An international multicenter randomized controlled trial was performed between 2002 and 2006. Inclusion criteria were birthweight >or=1000 g and pneumoperitoneum on x-ray (necrotizing enterocolitis or isolated perforation). Patients were randomized to peritoneal drain or laparotomy, minimizing differences in weight, gestation, ventilation, inotropes, platelets, country, and on-site surgical facilities. Patients randomized to drain were allowed to have a delayed laparotomy after at least 12 hours of no clinical improvement. Sixty-nine patients were randomized (35 drain, 34 laparotomy); 1 subsequently withdrew consent. Six-month survival was 18/35 (51.4%) with a drain and 21/33 (63.6%) with laparotomy (P = 0.3; difference 12% 95% CI, -11, 34%). Cox regression analysis showed no significant difference between groups (hazard ratio for primary drain 1.6; P = 0.3; 95% CI, 0.7-3.4). Delayed laparotomy was performed in 26/35 (74%) patients after a median of 2.5 days (range, 0.4-21) and did not improve 6-month survival compared with primary laparotomy (relative risk of mortality 1.4; P = 0.4; 95% CI, 0.6-3.4). Drain was effective as a definitive treatment in only 4/35 (11%) surviving neonates, the rest either had a delayed laparotomy or died. Seventy-four percent of neonates treated with primary peritoneal drainage required delayed laparotomy. There were no significant differences in outcomes between the 2 randomization groups. Primary peritoneal drainage is ineffective as either a temporising measure or definitive treatment. If a drain is inserted, a timely "rescue" laparotomy should be considered. Trial registration number ISRCTN18282954; http://isrctn.org/

  12. Using MODFLOW drains to simulate groundwater flow in a karst environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, J.; Tomasko, D.; Glennon, M.A.

    1998-07-01

    Modeling groundwater flow in a karst environment is both numerically challenging and highly uncertain because of potentially complex flowpaths and a lack of site-specific information. This study presents the results of MODFLOW numerical modeling in which drain cells in a finite-difference model are used as analogs for preferential flowpaths or conduits in karst environments. In this study, conduits in mixed-flow systems are simulated by assigning connected pathways of drain cells from the locations of tracer releases, sinkholes, or other karst features to outlet springs along inferred flowpaths. These paths are determined by the locations of losing stream segments, ephemeral streammore » beds, geophysical surveys, fracture lineaments, or other surficial characteristics, combined with the results of dye traces. The elevations of the drains at the discharge ends of the inferred flowpaths are estimated from field data and are adjusted when necessary during model calibration. To simulate flow in a free-flowing conduit, a high conductance is assigned to each drain to eliminate the need for drain-specific information that would be very difficult to obtain. Calculations were performed for a site near Hohenfels, Germany. The potentiometric surface produced by the simulations agreed well with field data. The head contours in the vicinity of the karst features behaved in a manner consistent with a flow system having both diffuse and conduit components, and the sum of the volumetric flow out of the drain cells agreed closely with spring discharges and stream flows. Because of the success of this approach, it is recommended for regional studies in which little site-specific information (e.g., location, number, size, and conductivity of fractures and conduits) is available, and general flow characteristics are desired.« less

  13. In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?

    PubMed

    Johnson, Charles H N; Lang, Sommer A; Bilal, Haris; Rammohan, Kandadai S

    2014-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?'. Altogether more than 200 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Subcutaneous emphysema is usually a benign, self-limiting condition only requiring conservative management. Interventions are useful in the context of severe patient discomfort, respiratory distress or persistent air leak. In the absence of any comparative study, it is not possible to choose definitively between infraclavicular incisions, drain insertion and increasing suction on an in situ drain as the best method for managing severe subcutaneous emphysema. All the three techniques described have been shown to provide effective relief. Increasing suction on a chest tube already in situ provided rapid relief in patients developing SE following pulmonary resection. A retrospective study showed resolution in 66%, increasing to 98% in those who underwent video-assisted thoracic surgery with identification and closure of the leak. Insertion of a drain into the subcutaneous tissue also provided rapid sustained relief. Several studies aided drainage by using regular compressive massage. Infraclavicular incisions were also shown to provide rapid relief, but were noted to be more invasive and carried the potential for cosmetic defect. No major complications were illustrated. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Drain data to predict clinically relevant pancreatic fistula

    PubMed Central

    Moskovic, Daniel J; Hodges, Sally E; Wu, Meng-Fen; Brunicardi, F Charles; Hilsenbeck, Susan G; Fisher, William E

    2010-01-01

    Background Post-operative pancreatic fistula (POPF) is a common and potentially devastating complication of pancreas resection. Management of this complication is important to the pancreas surgeon. Objective The aim of the present study was to evaluate whether drain data accurately predicts clinically significant POPF. Methods A prospectively maintained database with daily drain amylase concentrations and output volumes from 177 consecutive pancreatic resections was analysed. Drain data, demographic and operative data were correlated with POPF (ISGPF Grade: A – clinically silent, B – clinically evident, C – severe) to determine predictive factors. Results Twenty-six (46.4%) out of 56 patients who underwent distal pancreatectomy and 52 (43.0%) out of 121 patients who underwent a Whipple procedure developed a POPF (Grade A-C). POPFs were classified as A (24, 42.9%) and C (2, 3.6%) after distal pancreatectomy whereas they were graded as A (35, 28.9%), B (15, 12.4%) and C (2, 1.7%) after Whipple procedures. Drain data analysis was limited to Whipple procedures because only two patients developed a clinically significant leak after distal pancreatectomy. The daily total drain output did not differ between patients with a clinical leak (Grades B/C) and patients without a clinical leak (no leak and Grade A) on post-operative day (POD) 1 to 7. Although the median amylase concentration was significantly higher in patients with a clinical leak on POD 1–6, there was no day that amylase concentration predicted a clinical leak better than simply classifying all patients as ‘no leak’ (maximum accuracy =86.1% on POD 1, expected accuracy by chance =85.6%, kappa =10.2%). Conclusion Drain amylase data in the early post-operative period are not a sensitive or specific predictor of which patients will develop clinically significant POPF after pancreas resection. PMID:20815856

  15. Chief Joseph Dam, Columbia River, Washington, Additional Units and Structural Modification Foundation Report

    DTIC Science & Technology

    1988-01-01

    diameter companion drain holes in the area below the intake structure. The second contract, DACW67-75-C-0042, was awarded to Goodfellow Brothers, Inc. in...tolerances for bolt anchors. Subhori- zontal companion drain holes were drilled adjacent to the rock bolt holes. Negligible ground water was encountered...excavation contract was then modified so that rock excavation would not go below elevation 799 feet. The contractor installed rock bolts and companion drain

  16. [The wound drainage after operation on thyroid gland].

    PubMed

    Nechay, A P; Smolyar, V A; Voytenko, V V; Sichinava, R M; Larin, A S; Cherenko, S M

    2015-03-01

    Efficacy of active draining, promoting the most rapid reconvalescence and rehabilitation of the patients, in comparison to passive wound draining was studied up in various diseases of thyroid gland and operative intervention volume. The autors have had concluded, that suturing of operative wound without draining after hemithyroidectomy conduction is possible, as well as a thyroidectomy for nodular and multinodular goiter, if the excised volume of the lobe/gland do not exceed 15 cm3 and in nonapplication of anticoagulants.

  17. Threshold Voltage Instability in A-Si:H TFTS and the Implications for Flexible Displays and Circuits

    DTIC Science & Technology

    2008-12-01

    and negative gate voltages with and without elevated drain voltages for FDC TFTs. Extending techniques used to localize hot electron degradation...in MOSFETs, experiments in our lab have localized the degradation of a-Si:H to the gate dielectric/a-Si:H channel interface [Shringarpure, et al...saturation, increased drain source current measured with the source and drain reversed indicates localization of ΔVth to the gate dielectric/amorphous

  18. Effects of groundwater pumping on agricultural drains in the Tule Lake subbasin, Oregon and California

    USGS Publications Warehouse

    Pischel, Esther M.; Gannett, Marshall W.

    2015-07-24

    To better define the effect of increased pumping on drain flow and on the water balance of the groundwater system, the annual water volume pumped from drains in three subareas of the Tule Lake subbasin was estimated and a fine-grid, local groundwater model of the Tule Lake subbasin was constructed. Results of the agricultural-drain flow analysis indicate that groundwater discharge to drains has decreased such that flows in 2012 were approximately 32,400 acre-ft less than the 1997–2000 average flow. This decrease was concentrated in the northern and southeastern parts of the subbasin, which corresponds with the areas of greatest groundwater pumping. Model simulation results of the Tule Lake subbasin groundwater model indicate that increased supplemental pumping is the dominant stress to the groundwater system in the subbasin. Simulated supplemental pumping and decreased recharge from irrigation between 2000 and 2010 totaled 323,573 acre-ft, 234,800 acre-ft (73 percent) of which was from supplemental pumping. The response of the groundwater system to this change in stress included about 180,500 acre-ft (56 percent) of decreased groundwater discharge to drains and a 126,000 acre-ft (39 percent) reduction in aquifer storage. The remaining 5 percent came from reduced groundwater flow to other model boundaries, including the Lost River, the Tule Lake sumps, and interbasin flow.

  19. The role of soil drainage class in carbon dioxide exchange and decomposition in boreal black spruce (Picea mariana) forest stands

    USGS Publications Warehouse

    Wickland, K.P.; Neff, J.C.; Harden, J.W.

    2010-01-01

    Black spruce (Picea mariana (Mill.) B.S.P.) forest stands range from well drained to poorly drained, typically contain large amounts of soil organic carbon (SOC), and are often underlain by permafrost. To better understand the role of soil drainage class in carbon dioxide (CO2) exchange and decomposition, we measured soil respiration and net CO2 fluxes, litter decomposition and litterfall rates, and SOC stocks above permafrost in three Alaska black spruce forest stands characterized as well drained (WD), moderately drained (MD), and poorly drained (PD). Soil respiration and net CO2 fluxes were not significantly different among sites, although the relation between soil respiration rate and temperature varied with site (Qw: WD > MD > PD). Annual estimated soil respiration, litter decomposition, and groundcover photosynthesis were greatest at PD. These results suggest that soil temperature and moisture conditions in shallow organic horizon soils at PD were more favorable for decomposition compared with the better drained sites. SOC stocks, however, increase from WD to MD to PD such that surface decomposition and C storage are diametric. Greater groundcover vegetation productivity, protection of deep SOC by permafrost and anoxic conditions, and differences in fire return interval and (or) severity at PD counteract the relatively high near-surface decomposition rates, resulting in high net C accumulation.

  20. Routine postoperative CT-scans after burr hole trepanation for chronic subdural hematoma - better before or after drainage removal?

    PubMed

    Brokinkel, Benjamin; Ewelt, Christian; Holling, Markus; Hesselmann, Volker; Heindel, Walter Leonard; Stummer, Walter; Fischer, Bernhard Robert

    2013-01-01

    To evaluate timing of scheduled CT-scans after burr hole trepanation for chronic subdural hematoma (cSDH). 131 patients with primary cSDH were included. Scheduled CT-scans were performed after burr hole trepanation and placement of a subdural drain. The influence of CT-scanning with or without indwelling drain was analysed regarding subsequent surgery and CT-scans, duration of hospitalization, short- and middle-term follow up by single factor analyses. Subgroup analyses were performed for patients receiving anticoagulant drugs. Median age was 74 years. Routine CT-scans with indwelling drainage were not shown to be beneficial regarding subsequent burr hole trepanations (p=0.243), craniotomies (p=1.000) and outcome at discharge (p=0.297). Mean duration of hospitalization (11 vs. 8 days, p=0.013) was significantly longer and number of subsequent CT-scans was higher when CT scan was performed with indwelling drain (2.3 vs. 1.4, p=0.001). In middle-term follow-up, beneficial effects of CT-scanning with inlaying drainage could neither be shown. Moreover, advantageous effects of CT-scans with indwelling drains could neither be shown for patients receiving anticoagulant drugs. Scheduled postoperative cranial imaging with indwelling drains was not shown to be beneficial and misses information of intracranial damage inflicted by removal of drains. We thus recommend CT-scanning after drainage removal.

  1. The Management of Cerebrospinal Fluid Leak After Anterior Cervical Decompression Surgery.

    PubMed

    Zhai, Jiliang; Panchal, Ripul R; Tian, Ye; Wang, Shujie; Zhao, Lijuan

    2018-03-01

    Cerebrospinal fluid (CSF) leak is a rare but potentially troublesome and occasionally catastrophic complication after anterior cervical decompression surgery. There is limited literature describing this complication, and the management of CSF leak varies. The aim of this study was to retrospectively review the treatment of cases with CSF leak and develop a management algorithm. A series of 14 patients with CSF leak from January 2011 to May 2016 were included in this study. Their characteristics, management of CSF leak, and outcomes were documented. There were 5 male and 9 female patients. Mean age at surgery was 57.1±9.9 years (range, 37-76 years). All instances of CSF leak, except 1 noted postoperatively, were indirectly repaired intraoperatively. A closed straight wound drain was placed for all patients. A lumbar subarachnoid drain was placed immediately after surgery in 4 patients and postoperatively in 7 patients. In 1 patient, lumbar drain placement was unsuccessful. In 2 additional patients, the surgeon decided not to place a lumbar drain. One patient developed meningitis and recovered after antibiotic therapy with meropenem and vancomycin. Another patient had a deep wound infection and required a revision surgery. Wound drains and lumbar drains should be immediately considered when CSF leak is identified. Antibiotics also should be considered to prevent intradural infection. [Orthopedics. 2018; 41(2):e283-e288.]. Copyright 2018, SLACK Incorporated.

  2. A Multi-Disciplinary Review of the Potential Association between Closed-Suction Drains and Surgical Site Infection

    PubMed Central

    Reiffel, Alyssa J.; Barie, Philip S.

    2013-01-01

    Abstract Background Despite the putative advantages conferred by closed-suction drains (CSDs), the widespread utilization of post-operative drains has been questioned due to concerns regarding both efficacy and safety, particularly with respect to the risk of surgical site infection (SSI). Although discipline-specific reports exist delineating risk factors associated with SSI as they relate to the presence of CSDs, there are no broad summary studies to examine this issue in depth. Methods The pertinent medical literature exploring the relationship between CSDs and SSI across multiple surgical disciplines was reviewed. Results Across most surgical disciplines, studies to evaluate the risk of SSI associated with routine post-operative CSD have yielded conflicting results. A few studies do suggest an increased risk of SSI associated with drain placement, but are usually associated with open drainage and not the use of CSDs. No studies whatsoever attribute a decrease in the incidence of SSI (including organ/space SSI) to drain placement. Conclusions Until additional, rigorous randomized trials are available to address the issue definitively, we recommend judicious use and prompt, timely removal of CSDs. Given that the evidence is scant and weak to suggest that CSD use is associated with increased risk of SSI, there is no justification for the prolongation of antibiotic prophylaxis to “cover” an indwelling drain. PMID:23718273

  3. Modeling and analysis of sub-surface leakage current in nano-MOSFET under cutoff regime

    NASA Astrophysics Data System (ADS)

    Swami, Yashu; Rai, Sanjeev

    2017-02-01

    The high leakage current in nano-meter regimes is becoming a significant portion of power dissipation in nano-MOSFET circuits as threshold voltage, channel length, and gate oxide thickness are scaled down to nano-meter range. Precise leakage current valuation and meticulous modeling of the same at nano-meter technology scale is an increasingly a critical work in designing the low power nano-MOSFET circuits. We present a specific compact model for sub-threshold regime leakage current in bulk driven nano-MOSFETs. The proposed logical model is instigated and executed into the latest updated PTM bulk nano-MOSFET model and is found to be in decent accord with technology-CAD simulation data. This paper also reviews various transistor intrinsic leakage mechanisms for nano-MOSFET exclusively in weak inversion, like drain-induced barricade lowering (DIBL), gate-induced drain leakage (GIDL), gate oxide tunneling (GOT) leakage etc. The root cause of the sub-surface leakage current is mainly due to the nano-scale short channel length causing source-drain coupling even in sub-threshold domain. Consequences leading to carriers triumphing the barricade between the source and drain. The enhanced model effectively considers the following parameter dependence in the account for better-quality value-added results like drain-to-source bias (VDS), gate-to-source bias (VGS), channel length (LG), source/drain junction depth (Xj), bulk doping concentration (NBULK), and operating temperature (Top).

  4. Comparative investigation of novel hetero gate dielectric and drain engineered charge plasma TFET for improved DC and RF performance

    NASA Astrophysics Data System (ADS)

    Yadav, Dharmendra Singh; Verma, Abhishek; Sharma, Dheeraj; Tirkey, Sukeshni; Raad, Bhagwan Ram

    2017-11-01

    Tunnel-field-effect-transistor (TFET) has emerged as one of the most prominent devices to replace conventional MOSFET due to its ability to provide sub-threshold slope below 60 mV/decade (SS ≤ 60 mV/decade) and low leakage current. Despite this, TFETs suffer from ambipolar behavior, lower ON-state current, and poor RF performance. To address these issues, we have introduced drain and gate work function engineering with hetero gate dielectric for the first time in charge plasma based doping-less TFET (DL TFET). In this, the usage of dual work functionality over the drain region significantly reduces the ambipolar behavior of the device by varying the energy barrier at drain/channel interface. Whereas, the presence of dual work function at the gate terminal increases the ON-state current (ION). The combined effect of dual work function at the gate and drain electrode results in the increment of ON-state current (ION) and decrement of ambipolar conduction (Iambi) respectively. Furthermore, the incorporation of hetero gate dielectric along with dual work functionality at the drain and gate electrode provides an overall improvement in the performance of the device in terms of reduction in ambipolarity, threshold voltage and sub-threshold slope along with improved ON-state current and high frequency figures of merit.

  5. Restructuring brain drain: strengthening governance and financing for health worker migration.

    PubMed

    Mackey, Tim K; Liang, Bryan A

    2013-01-15

    Health worker migration from resource-poor countries to developed countries, also known as ''brain drain'', represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  6. Growth and seed production of sawtooth oak (`quercus acutissima`) 22 years after direct seeding. Forest Service research note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goelz, J.C.G.; Carlson, D.W.

    Sawtooth oak (Quercus acutissima Carruth) was direct seeded at two locations, one with a poorly drained clay soil and the other with a well-drained silty clay loam. For comparison, Nuttall oak (Q. nuttallii Palmer) was direct seeded on the poorly drained clay soil. On the well-drained silty clay loam, sawtooth oak was 18 ft taller and 2.4 inches larger in d.b.h. at age 22 than on the poorly drained clay soil. On the clay, sawtooth oak grew faster than Nuttall oak, but survival was lower. Almost all sawtooth oaks were producing acorns on both sites; however, no developing acorns weremore » found on the Nuttall oaks. Sawtooth oak is a viable alternative for planting on a wide range of Mississippi Delta forest types. Because sawtooth oak has a poorer form than Nuttal oak, its primary use is as a source of wildlife food. Sawtooth oak could be included in plantings with the multiple objectives of timber production and wildlife use because it grows well and could potentially be used for pulpwood.« less

  7. Knee arthroplasty and bleeding: when to remove drainages.

    PubMed

    Ares, Oscar; Seijas, Roberto; Hernandez, Alberto; Castellet, Enric; Sallent, Andrea

    2013-02-01

    The aim of this study is an attempt to clarify the productive time of drainages as we find that the use of drains in knee arthroplasty is controversial, and there is no consensus regarding their length-time maintenance. We analysed the survival curve of bleeding within three surgical techniques for knee arthroplasty and the effect of two variables on survival curve. One hundred and eighty-eight out of 234 knees were included in the study, and patients were divided into three groups according to the surgical technique: conventional total knee arthroplasty (TKA), subvastus TKA and unicompartmental knee arthroplasty. Variables of study were type of surgery, number and placement of drains. Mean of survival curve for postoperative bleeding time was 16 h (95 % CI: 15.4; 16.6). The risk for longer bleeding increased 1.38-fold with each additional drain used (95 % CI 1.1; 1.8). According to the present study, drains can be safely removed at around 17 h postoperative. Bleeding time reduces as less drains are applied. Therapeutic study, Level III.

  8. Effect of tube drainage compared with conventional suturing on postoperative discomfort after extraction of impacted mandibular third molars.

    PubMed

    Koyuncu, B Ö; Zeytinoğlu, M; Tetik, A; Gomel, M M

    2015-01-01

    The aim of this prospective randomised study was to assess the effects of tube drainage on postoperative discomfort after the extraction of impacted mandibular third molars. We studied 40 patients (11 men and 29 women) 18 years or older (mean (SD) 21 (3), range 18-29) who required extraction of mandibular third molars. We used a randomised crossover design by which if a drain was inserted on one side, then the other side was managed without a drain on a later occasion. Pain, swelling, and mouth opening were evaluated after 48 h and 7 days postoperatively in both groups. Facial swelling (p=0.001), pain p=0.001), and trismus (p=0.001) were significantly less common in the drained group compared with those not drained. We conclude that the use a tube drain is of benefit in minimising postoperative swelling, pain, and trismus after extraction of mandibular third molars. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Sediment transport by irrigation return flows in four small drains within the DID-18 drainage of the Sulphur Creek basin, Yakima County, Washington, April 1979 to October 1981

    USGS Publications Warehouse

    Boucher, P.R.

    1984-01-01

    Suspended sediment, water discharges, and water temperatures were monitored in four small drains in the DID-18 basin of the Sulphur Creek basin, a tributary to the Yakima River, Washington. Water outflow, inflow, and miscellaneous sites were also monitored. The information was used to evaluate the effectiveness of management practices in reducing sediment loads in irrigated areas. This study was one of seven Model Implementation Plan projects selected by the U.S. Soil Conservation Service and the U.S. Environmental Protection Agency to demonstrate the effectiveness of institutional and administrative implementation of management plans. Sediment discharges from the four basins could not be correlated with changes in management practices, because Imhoff Cone readings collected for the study showed no statistical differences between the three irrigation seasons. However, one drain acted as a sink for sediment where more lands were sprinkler irrigated; this drain had a smaller proportion of row crops than did the other three drains. (USGS)

  10. Efficacy of short-term versus long-term chest tube drainage following talc slurry pleurodesis in patients with malignant pleural effusions: a randomised trial.

    PubMed

    Goodman, Anna; Davies, Christopher W H

    2006-10-01

    Talc pleurodesis is commonly used in the palliative treatment of malignant pleural effusions but the shortest and most effective regime has not been determined. In particular, it is not clear when the intercostal drain should be removed following the insertion of sclerosant. We conducted a single-centre, randomised, open trial of drain removal at 24 h versus 72 h following talc slurry pleurodesis. The primary outcome measure was success of pleurodesis (no recurrence of effusion on chest radiograph at 1-month follow-up) and secondary outcome measures included length of hospital stay and mortality. We found no difference between recurrence of pleural effusion in those randomised to drain removal at 24 h and those randomised to drain removal at 72 h (p>0.5). However, length of stay was significantly reduced when the chest drain was removed at 24 h (4 days versus 8 days; p<0.01). Mortality did not differ between the two groups. We conclude that this shorter pleurodesis regime is safe and effective.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.

    Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less

  12. Effects of land use on greenhouse gas fluxes and soil properties of wetland catchments in the Prairie Pothole Region of North America

    USGS Publications Warehouse

    Tangen, Brian A.; Finocchiaro, Raymond G.; Gleason, Robert A.

    2015-01-01

    Results suggest that soil organic carbon is lost when relatively undisturbed catchments are converted for agriculture, and that when non-drained cropland catchments are restored, CH4 fluxes generally are not different than the pre-restoration baseline. Conversely, when drained cropland catchments are restored, CH4 fluxes are noticeably higher. Consequently, it is important to consider the type of wetland restoration (drained, non-drained) when assessing restoration benefits. Results also suggest that elevated N2O fluxes from cropland catchments likely would be reduced through restoration. The overall variability demonstrated by this study was consistent with findings of other wetland investigations and underscores the difficulty in quantifying the GHG balance of wetland systems.

  13. Dual drain MOSFET detector for crosstie memory systems

    NASA Astrophysics Data System (ADS)

    Bluzer, N.

    1985-03-01

    This patent application, which discloses a circuit for detecting binary information in crosstie memory systems includes a dual drain MOSFET device having a single channel with a common source and an integrated, thin-film strip of magnetic material suitable for the storage and propagation of Bloch line-crosstie pairs acting as both a shift register and the device's gate. Current flowing through the device, in the absence of a magnetic field, is equally distributed to each drain; however, changing magnetic fields, normal to the plane of the device and generated by Bloch line-crosstie pairs in the strip, interact with the current such that a distribution imbalance exists and one drain or the other receives a disproportionate fraction of the current depending upon the direction of the magnetic field.

  14. Contoured tank outlets for draining of cylindrical tanks in low-gravity environment. [Lewis Research Center Zero Gravity Facility

    NASA Technical Reports Server (NTRS)

    Symons, E. P.

    1979-01-01

    An analysis is presented for defining the outlet contour of a hemispherical-bottomed cylindrical tank that will prevent vapor ingestion when the tank is drained. The analysis was used to design two small-scale tanks that were fabricated and then tested in a low gravity environment. The draining performance of the tanks was compared with that for a tank with a conventional outlet having a constant circular cross-sectional area, under identical conditions. Even when drained at off-design conditions, the contoured tank had less liquid residuals at vapor ingestion than the conventional outlet tank. Effects of outflow rate, gravitational environment, and fluid properties on the outlet contour are discussed. Two potential applications of outlet contouring are also presented and discussed.

  15. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    PubMed

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  16. Suppression of ambipolar current in tunnel FETs using drain-pocket: Proposal and analysis

    NASA Astrophysics Data System (ADS)

    Garg, Shelly; Saurabh, Sneh

    2018-01-01

    In this paper, we investigate the impact of a drain-pocket (DP) adjacent to the drain region in Tunnel Field-Effect Transistors (TFETs) to effectively suppress the ambipolar current. Using calibrated two-dimensional device simulation, we examine the impact of DP in Double Gate TFET (DGTFET). We demonstrate the superiority of the DP technique over the existing techniques in controlling the ambipolar current. In particular, the addition of DP to a TFET is able to fully suppress the ambipolar current even when TFET is biased at high negative gate voltages and drain doping is kept as high as the source doping. Moreover, adding DP is complementary to the well-known technique of employ-ing source-pocket (SP) in a TFET since both need similar doping type and doping concentration.

  17. High temperature-induced abnormal suppression of sub-threshold swing and on-current degradations under hot-carrier stress in a-InGaZnO thin film transistors

    NASA Astrophysics Data System (ADS)

    Tsai, Ming-Yen; Chang, Ting-Chang; Chu, Ann-Kuo; Hsieh, Tien-Yu; Chen, Te-Chih; Lin, Kun-Yao; Tsai, Wu-Wei; Chiang, Wen-Jen; Yan, Jing-Yi

    2013-07-01

    This letter investigates the effect of temperature on hot-carrier stress-induced degradation behavior in InGaZnO thin film transistors. After hot-carrier stress at 25 °C, serious on-current and subthreshold swing degradations are observed due to trap state generation near the drain side. For identical stress performed at elevated temperatures, current degradation in the I-V transfer curve under reverse mode is gradually suppressed and the anomalous hump in the gate-to-drain capacitance-voltage curve becomes more severe. These suppressed degradations and the more severe hump can be both attributed to hole-trapping near the drain side due to high drain bias at high temperature.

  18. EVALUATION OF FABRIC MEMBRANES FOR USE IN SALTSTONE DRAIN WATER SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickenheim, B.; Miller, D.; Burket, P.

    2012-03-08

    Saltstone Disposal Unit 2 contains a sheet drain fabric intended to separate solids from drain water to be returned to the Salt Feed Tank. A similar system installed in Vault 4 appears to be ineffective in keeping solids out of the drain water return lines. Waste Solidification Engineering is considering installation of an additional fabric membrane to supplement the existing sheet drain in SDU 2. Amerdrain 200 is the product currently installed in SDU 2. This product is no longer available, so Sitedrain 94 was used as the replacement product in this testing. Fabrics with apparent opening sizes of 10,more » 25, 50 and 100 microns were evaluated. These fabrics were evaluated under three separate test conditions, a water flow test, a solids retention test and a grout pour test. A flow test with water showed that installation of an additional filter layer will predictably reduce the theoretical flux through the sheet drain. The manufacturer reports the flux for Sitedrain 94 as 150 gpm/ft{sup 2} by ASTM D-4491. This compares reasonably well with the 117 gpm/ft{sup 2} obtained in this testing. A combination of the 10 micron fabric with Sitedrain 94 could be expected to decrease flux by about 10 times as compared to Sitedrain 94 alone. The different media were used to filter a slag and fly ash mixture from water. Slag historically has the smallest nominal particle size of the premix components. Cement was omitted from the test because of its reactivity with water would prohibit accurately particle size measurements of the filtered samples. All four media sizes were able to remove greater than 95% of particles larger than 100 microns from the slurry. The smaller opening sizes were increasingly effective in removing more particles. The 10 micron filter captured 15% of the total amount of solids used in the test. This result implies that some insoluble particles may still be able to enter the drain water collection system, although the overall solids rejection is significantly improved over the current design. Test boxes were filled with grout to evaluate the performance of the sheet drain and fabrics in a simulated vault environment. All of the tests produced a similar amount of drain water, between 8-11% of the amount of water in the mix, which is expected with the targeted formulation. All of the collected drain waters contained some amount of solids, although the 10 micron filter did not appear to allow any premix materials to pass through. The solids collected from this box are believed to consist of calcium carbonate based on one ICP-AES measurement. Any of the four candidate fabrics would be an improvement over the sheet drain alone relative to solids removal. The 10 micron fabric is the only candidate that stopped all premix material from passing. The 10 micron fabric will also cause the largest decrease in flux. This decrease in flux was not enough to inhibit the total amount of drain water removed, but may lead to increased time to remove standing water prior to subsequent pours in the facility. The acceptability of reduced liquid flux through the 10 micron fabric will depend on the amount of excess water to be removed, the time available for water removal and the total area of fabric installed at the disposal cell.« less

  19. Rainfall, discharge, and water-quality data during stormwater monitoring, H-1 storm drain, Oahu, Hawaii, July 1, 2009, to June 30, 2010

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2010-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.

  20. Depression (For Teens)

    MedlinePlus

    ... good things in life. Depression drains the energy, motivation, and concentration a person needs for normal activities. ... a problem is actually temporary. Low energy and motivation. People with depression may feel tired, drained, or ...

  1. [Late results of surgical treatment in patients, suffering complicated forms of chronic pancreatitis].

    PubMed

    Ratchyk, V M; Orlovs'kyĭ, D V; Makarchuk, V A; Zemlians'kyĭ, D É; Orlovs'kyĭ, V V

    2014-12-01

    Late results of treatment were analyzed in 58 patients, suffering complicated forms of chronic pancreatitis, to whom draining and resectional-draining surgical interventions were performed. On average the patients age was (49.90 ± 8.59) yrs, there were 42 (72.4%) men and 16 (27.6%) women. During period of the 3 yrs postoperative follow- up in the patients the pain syndrome severity have reduced essentially and quality of life improved, comparing with those indices after resectional-draining interventions.

  2. Massachusetts Institute of Technology Lincoln Laboratory Facilities Replacement on Hanscom Air Force Base Phase 1 Final Environmental Assessment

    DTIC Science & Technology

    2014-07-24

    Service UST Underground Storage Tank VC Vitrified Clay VOCs Volatile Organic Compounds W Watts 1 1.0 PURPOSE AND NEED FOR ACTION 1.1 INTRODUCTION The...discharged to sanitary drain and the solids slurry is hauled off site for disposal Fluoride drain: welded stainless steel drain piping from wet...diameter vitrified clay (VC) gravity sewer collection pipe, flowing north/northeast to the upper pumping station at Building 1306, is located within the

  3. Two cases of left superior vena cava draining directly to a left atrium with a normal coronary sinus.

    PubMed Central

    Wiles, H B

    1991-01-01

    The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125

  4. SONOS Nonvolatile Memory Cell Programming Characteristics

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd C.; Phillips, Thomas A.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile memory is gaining favor over conventional EEPROM FLASH memory technology. This paper characterizes the SONOS write operation using a nonquasi-static MOSFET model. This includes floating gate charge and voltage characteristics as well as tunneling current, voltage threshold and drain current characterization. The characterization of the SONOS memory cell predicted by the model closely agrees with experimental data obtained from actual SONOS memory cells. The tunnel current, drain current, threshold voltage and read drain current all closely agreed with empirical data.

  5. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Air Force Plant 38, Porter, New York

    DTIC Science & Technology

    1988-04-01

    drainageways collect surface runoff at the plant and channel the water off plant property. These are: the Central Drain- age Ditch, the Magazine Ditch, and...past, this drain- age system collected test area deluge waters , small spills from test- ing areas, and drainage from around the flush and maintenance...Drain- age Ditch Table 4-2 shows the results of the analyses of two water samples and one soil/sediment sample that were obtained from the drainage from

  6. 46 CFR 76.15-15 - Piping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... necessary, protected against injury. (g) Drains and dirt traps shall be fitted where necessary to prevent the accumulation of dirt or moisture. Drains and dirt traps shall be located in accessible locations...

  7. N loss to drain flow and N2O emissions from a corn-soybean rotation with winter rye.

    PubMed

    Gillette, K; Malone, R W; Kaspar, T C; Ma, L; Parkin, T B; Jaynes, D B; Fang, Q X; Hatfield, J L; Feyereisen, G W; Kersebaum, K C

    2018-03-15

    Anthropogenic perturbation of the global nitrogen cycle and its effects on the environment such as hypoxia in coastal regions and increased N 2 O emissions is of increasing, multi-disciplinary, worldwide concern, and agricultural production is a major contributor. Only limited studies, however, have simultaneously investigated NO 3 - losses to subsurface drain flow and N 2 O emissions under corn-soybean production. We used the Root Zone Water Quality Model (RZWQM) to evaluate NO 3 - losses to drain flow and N 2 O emissions in a corn-soybean system with a winter rye cover crop (CC) in central Iowa over a nine year period. The observed and simulated average drain flow N concentration reductions from CC were 60% and 54% compared to the no cover crop system (NCC). Average annual April through October cumulative observed and simulated N 2 O emissions (2004-2010) were 6.7 and 6.0kgN 2 O-Nha -1 yr -1 for NCC, and 6.2 and 7.2kgNha -1 for CC. In contrast to previous research, monthly N 2 O emissions were generally greatest when N loss to leaching were greatest, mostly because relatively high rainfall occurred during the months fertilizer was applied. N 2 O emission factors of 0.032 and 0.041 were estimated for NCC and CC using the tested model, which are similar to field results in the region. A local sensitivity analysis suggests that lower soil field capacity affects RZWQM simulations, which includes increased drain flow nitrate concentrations, increased N mineralization, and reduced soil water content. The results suggest that 1) RZWQM is a promising tool to estimate N 2 O emissions from subsurface drained corn-soybean rotations and to estimate the relative effects of a winter rye cover crop over a nine year period on nitrate loss to drain flow and 2) soil field capacity is an important parameter to model N mineralization and N loss to drain flow. Published by Elsevier B.V.

  8. Targeting sediment management strategies using sediment quantification and fingerprinting methods

    NASA Astrophysics Data System (ADS)

    Sherriff, Sophie; Rowan, John; Fenton, Owen; Jordan, Phil; hUallacháin, Daire Ó.

    2016-04-01

    Cost-effective sediment management is required to reduce excessive delivery of fine sediment due to intensive land uses such as agriculture, resulting in the degradation of aquatic ecosystems. Prioritising measures to mitigate dominant sediment sources is, however, challenging, as sediment loss risk is spatially and temporally variable between and within catchments. Fluctuations in sediment supply from potential sources result from variations in land uses resulting in increased erodibility where ground cover is low (e.g., cultivated, poached and compacted soils), and physical catchment characteristics controlling hydrological connectivity and transport pathways (surface and/or sub-surface). Sediment fingerprinting is an evidence-based management tool to identify sources of in-stream sediments at the catchment scale. Potential sediment sources are related to a river sediment sample, comprising a mixture of source sediments, using natural physico-chemical characteristics (or 'tracers'), and contributions are statistically un-mixed. Suspended sediment data were collected over two years at the outlet of three intensive agricultural catchments (approximately 10 km2) in Ireland. Dominant catchment characteristics were grassland on poorly-drained soils, arable on well-drained soils and arable on moderately-drained soils. High-resolution (10-min) calibrated turbidity-based suspended sediment and discharge data were combined to quantify yield. In-stream sediment samples (for fingerprinting analysis) were collected at six to twelve week intervals, using time-integrated sediment samplers. Potential sources, including stream channel banks, ditches, arable and grassland field topsoils, damaged road verges and tracks were sampled, oven-dried (<40oC) and sieved (125 microns). Soil and sediment samples were analysed for mineral magnetics, geochemistry and radionuclide tracers, particle size distribution and soil organic carbon. Tracer data were corrected to account for particle size and organic matter selectivity processes. Contributions from potential sources type groups (channel - ditches and stream banks, roads - road verges and tracks, fields - grassland and arable topsoils) were statistically un-mixed using FR2000, an uncertainty-inclusive algorithm, and combined with sediment yield data. Results showed sediment contributions from channel, field and road groups were 70%, 25% and 5% in the poorly-drained catchment, 59%, 22% and 19% in the well-drained catchment, and 17%, 74% and 9% in the moderately-drained catchment. Higher channel contributions in the poorly-drained catchment were attributed to bank erosion accelerated by the rapid diversion of surface runoff into channels, facilitated by surface and sub-surface artificial drainage networks, and bank seepage from lateral pressure gradients due to confined groundwater. Despite the greatest proportion of arable soils in the well-drained catchment, this source was frequently hydrologically disconnected as well-drained soils largely infiltrated rainfall and prevented surface soil erosion. Periods of high and intense rainfall were associated with greater proportions of field losses in the well-drained catchment likely due to infiltration exceeding the saturated hydraulic conductivity of soils and establishment of surface hydrological connectivity. Losses from field topsoils dominated in the moderately-drained catchment as antecedent soil wetness maintained surface flow pathways and coincided with low groundcover on arable soils. For cost-effective management of sediment pressures to aquatic ecosystems, catchment specific variations in sediment sources must be considered.

  9. Spatial Variability of Tree Transpiration Along a Soil Drainage Gradient of Boreal Black Spruce Forest

    NASA Astrophysics Data System (ADS)

    Angstmann, J. L.; Ewers, B. E.; Kwon, H.; Bond-Lamberty, B.; Amiro, B.; Gower, S. T.

    2008-12-01

    Boreal forests are an integral component in obtaining a predictive understanding of global climate change because they comprise 33% of the world's forests and store large amounts of carbon. Much of this carbon storage is a result of peat formation in cold, poorly-drained soils. Transpiration plays a crucial role in the interaction between carbon and water cycles due to stomatal control of these fluxes. The primary focus of this study is to quantify the spatial variability and drivers of tree transpiration in boreal forest stands across a well- to poorly-drained soil drainage gradient. Species composition of this region of boreal forest changes during succession in well-drained soils from being primarily dominated by Picea mariana with co-dominant Pinus banksiana and Populus tremuloides in younger stands to being dominated solely by Picea marianain older stands. Poorly-drained soils are dominated by Picea mariana and change little with succession. Previous work in well-drained stands showed that 1) tree transpiration changed substantially with stand age due to sapwood-to-leaf area ratio dynamics and 2) minimum leaf water potential (Ψ) was kept constant to prevent excessive cavitation. We hypothesized that 1) minimum Ψ would be constant, 2) transpiration would be proportional to the sapwood-to-leaf area ratio across a soil drainage gradient, and 3) spatial relationships between trees would vary depending on stomatal responses to vapor pressure deficit (D). We tested these hypotheses by measuring Ψ of 33 trees and sap flux from 204 trees utilizing cyclic sampling constructed to study spatial relationships. Measurements were conducted at a 42-year-old stand representing maximum tree diversity during succession. There were no significant differences between growing season averaged Ψ in well- (-0.35 and -1.37 for pre-dawn and mid-day respectively) and poorly- drained soil conditions (-0.38 and -1.41 for pre-dawn and mid-day respectively) for Picea mariana. Water use results of Picea mariana differed between drainage conditions when expressed per unit xylem area with trees in poorly-drained soils experiencing higher rates than trees in well-drained areas (101.79 and 83.02 g cm-2 day-1 respectively). In contrast, when expressed as transpiration per tree, trees on well-drained soils had higher rates than those in poorly-drained locations (366.96 and 216.82 g tree-1 day-1 respectively). This indicates that tree size, reflected in sapwood area per ground area, which is constrained by anaerobic conditions across well- to poorly-drained areas, is driving differences in tree transpiration. Initial spatial analyses show that spatial autocorrelation decreases from 51.3 to 24.6 meters as D increases from 0.9 to 2.1 kPa. This phenomenon is explained by tree hydraulics and more patchy stomatal response as trees regulate water loss. Thus, regional scale bottom-up process models of boreal forest transpiration can be simplified with respect to soil drainage while retaining mechanistic rigor with respect to plant hydraulics.

  10. 46 CFR 34.15-15 - Piping-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and where necessary, protected against injury. (g) Drains and dirt traps shall be fitted where necessary to prevent the accumulation of dirt or moisture. Drains and dirt traps shall be located in...

  11. Modeling of Metal-Ferroelectric-Semiconductor Field Effect Transistors

    NASA Technical Reports Server (NTRS)

    Duen Ho, Fat; Macleod, Todd C.

    1998-01-01

    The characteristics for a MFSFET (metal-ferroelectric-semiconductor field effect transistor) is very different than a conventional MOSFET and must be modeled differently. The drain current has a hysteresis shape with respect to the gate voltage. The position along the hysteresis curve is dependent on the last positive or negative polling of the ferroelectric material. The drain current also has a logarithmic decay after the last polling. A model has been developed to describe the MFSFET drain current for both gate voltage on and gate voltage off conditions. This model takes into account the hysteresis nature of the MFSFET and the time dependent decay. The model is based on the shape of the Fermi-Dirac function which has been modified to describe the MFSFET's drain current. This is different from the model proposed by Chen et. al. and that by Wu.

  12. Investigation of Gate-Stacked In-Ga-Zn-O TFTs with Ga-Zn-O Source/Drain Electrodes by Atmospheric Pressure Plasma-Enhanced Chemical Vapor Deposition.

    PubMed

    Wu, Chien-Hung; Chang, Kow-Ming; Chen, Yi-Ming; Huang, Bo-Wen; Zhang, Yu-Xin; Wang, Shui-Jinn; Hsu, Jui-Mei

    2018-03-01

    Atmospheric pressure plasma-enhanced chemical vapor deposition (AP-PECVD) was employed for the fabrication of indium gallium zinc oxide thin-film transistors (IGZO TFTs) with high transparent gallium zinc oxide (GZO) source/drain electrodes. The influence of post-deposition annealing (PDA) temperature on GZO source/drain and device performance was studied. Device with a 300 °C annealing demonstrated excellent electrical characteristics with on/off current ratio of 2.13 × 108, saturation mobility of 10 cm2/V-s, and low subthreshold swing of 0.2 V/dec. The gate stacked LaAlO3/ZrO2 of AP-IGZO TFTs with highly transparent and conductive AP-GZO source/drain electrode show excellent gate control ability at a low operating voltage.

  13. Monogroove liquid heat exchanger

    NASA Technical Reports Server (NTRS)

    Brown, Richard F. (Inventor); Edelstein, Fred (Inventor)

    1990-01-01

    A liquid supply control is disclosed for a heat transfer system which transports heat by liquid-vapor phase change of a working fluid. An assembly (10) of monogroove heat pipe legs (15) can be operated automatically as either heat acquisition devices or heat discharge sources. The liquid channels (27) of the heat pipe legs (15) are connected to a reservoir (35) which is filled and drained by respective filling and draining valves (30, 32). Information from liquid level sensors (50, 51) on the reservoir (35) is combined (60) with temperature information (55) from the liquid heat exchanger (12) and temperature information (56) from the assembly vapor conduit (42) to regulate filling and draining of the reservoir (35), so that the reservoir (35) in turn serves the liquid supply/drain needs of the heat pipe legs (15), on demand, by passive capillary action (20, 28).

  14. Ensemble Monte Carlo particle investigation of hot electron induced source-drain burnout characteristics of GaAs field-effect transistors

    NASA Astrophysics Data System (ADS)

    Moglestue, C.; Buot, F. A.; Anderson, W. T.

    1995-08-01

    The lattice heating rate has been calculated for GaAs field-effect transistors of different source-drain channel design by means of the ensemble Monte Carlo particle model. Transport of carriers in the substrate and the presence of free surface charges are also included in our simulation. The actual heat generation was obtained by accounting for the energy exchanged with the lattice of the semiconductor during phonon scattering. It was found that the maximum heating rate takes place below the surface near the drain end of the gate. The results correlate well with a previous hydrodynamic energy transport estimate of the electronic energy density, but shifted slightly more towards the drain. These results further emphasize the adverse effects of hot electrons on the Ohmic contacts.

  15. A surface-potential-based drain current compact model for a-InGaZnO thin-film transistors in Non-Degenerate conduction regime

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Ma, Xiaoyu; Deng, Wanling; Liou, Juin J.; Huang, Junkai

    2017-11-01

    A physics-based drain current compact model for amorphous InGaZnO (a-InGaZnO) thin-film transistors (TFTs) is proposed. As a key feature, the surface potential model accounts for both exponential tail and deep trap densities of states, which are essential to describe a-InGaZnO TFT electrical characteristics. The surface potential is solved explicitly without the process of amendment and suitable for circuit simulations. Furthermore, based on the surface potential, an explicit closed-form expression of the drain current is developed. For the cases of the different operational voltages, surface potential and drain current are verified by numerical results and experimental data, respectively. As a result, our model can predict DC characteristics of a-InGaZnO TFTs.

  16. Photocurrent microscopy of contact resistance and charge carrier traps in organic field-effect transistors

    NASA Astrophysics Data System (ADS)

    Liewald, C.; Reiser, D.; Westermeier, C.; Nickel, B.

    2016-08-01

    We use a pentacene transistor with asymmetric source drain contacts to test the sensitivity of scanning photocurrent microscopy (SPCM) for contact resistance and charge traps. The drain current of the device strongly depends on the choice of the drain electrode. In one case, more than 94% of the source drain voltage is lost due to contact resistance. Here, SPCM maps show an enhanced photocurrent signal at the hole-injecting contact. For the other bias condition, i.e., for ohmic contacts, the SPCM signal peaks heterogeneously along the channel. We argue from basic transport models that bright areas in SPCM maps indicate areas of large voltage gradients or high electric field strength caused by injection barriers or traps. Thus, SPCM allows us to identify and image the dominant voltage loss mechanism in organic field-effect transistors.

  17. A novel double gate MOSFET by symmetrical insulator packets with improved short channel effects

    NASA Astrophysics Data System (ADS)

    Ramezani, Zeinab; Orouji, Ali A.

    2018-03-01

    In this article, we study a novel double-gate SOI MOSFET structure incorporating insulator packets (IPs) at the junction between channel and source/drain (S/D) ends. The proposed MOSFET has great strength in inhibiting short channel effects and OFF-state current that are the main problems compared with conventional one due to the significant suppressed penetrations of both the lateral electric field and the carrier diffusion from the S/D into the channel. Improvement of the hot electron reliability, the ON to OFF drain current ratio, drain-induced barrier lowering, gate-induced drain leakage and threshold voltage over conventional double-gate SOI MOSFETs, i.e. without IPs, is displayed with the simulation results. This study is believed to improve the CMOS device reliability and is suitable for the low-power very-large-scale integration circuits.

  18. Anatomical variations in lymphatic drainage of the right lung: applications in lung cancer surgery.

    PubMed

    Ndiaye, Assane; Di-Marino, V; Ba, P S; Ndiaye, Aï; Gaye, M; Nazarian, S

    2016-12-01

    To specify the topography and variations in lymphatic drainage of the right lung to the mediastinum and their therapeutic implications in non-small cell lung cancers (NSCLC). We injected a dye into the subpleural lymphatic vessels in 65 right lung segments, followed by dissection in 22 subjects. At the upper lobe, we had injected 32 segments. We noted extrasegmental overflow in one case; extrasegmental and extralobar drainage in two cases; drainage to the lymph nodes of another lobe in one case. Fifty-six percent of the segments drained directly (skipping intrapulmonary and hilar lymph nodes) into the right paratracheal lymph nodes, and one dorsal segment drained into the thoracic duct. A ventral segment drained into the inferior tracheobronchial lymph nodes. A contralateral drainage to the recurrent chain was observed in two cases. Sixteen segments of the middle lobe were injected and mainly drained into the inferior tracheobronchial lymph nodes with six direct paths; one medial segment drained into the right anterior mediastinal chain. We noted three contralateral drainages and eight downward abdominal drainages. Out of the 17 segments of the lower lobe injected, 6 segments drained into the lymph nodes of another lobe, 5 segments showed a direct route to the lower quadrant chains. We noted one time a drainage into the paraesophageal lymph nodes. The variations in lymphatic drainage of the right lung require to carry out systematically a radical mediastinal lymphadenectomy during the removal of non-small cell lung cancers and to associate an adjuvant treatment.

  19. Use of laterally placed vacuum drains for management of aural hematomas in five dogs.

    PubMed

    Pavletic, Michael M

    2015-01-01

    5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.

  20. Azolla pinnata growth performance in different water sources.

    PubMed

    Nordiah, B; Harah, Z Muta; Sidik, B Japar; Hazma, W N Wan

    2012-07-01

    Azolla pinnata R.Br. growth performance experiments in different water sources were conducted from May until July 2011 at Aquaculture Research Station, Puchong, Malaysia. Four types of water sources (waste water, drain water, paddy field water and distilled water) each with different nutrient contents were used to grow and evaluate the growth performance of A. pinnata. Four water sources with different nutrient contents; waste, drain, paddy and distilled water as control were used to evaluate the growth performance of A. pinnata. Generally, irrespective of the types of water sources there were increased in plant biomass from the initial biomass (e.g., after the first week; lowest 25.2% in distilled water to highest 133.3% in drain water) and the corresponding daily growth rate (3.61% in distilled water to 19.04% in drain water). The increased in biomass although fluctuated with time was consistently higher in drain water compared to increased in biomass for other water sources. Of the four water sources, drain water with relatively higher nitrate concentration (0.035 +/- 0.003 mg L(-l)) and nitrite (0.044 +/- 0.005 mg L(-1)) and with the available phosphate (0.032 +/- 0.006 mg L(-1)) initially provided the most favourable conditions for Azolla growth and propagation. Based on BVSTEP analysis (PRIMER v5), the results indicated that a combination of more than one nutrient or multiple nutrient contents explained the observed increased in biomass of A. pinnata grown in the different water sources.

  1. Investigation and statistical modeling of InAs-based double gate tunnel FETs for RF performance enhancement

    NASA Astrophysics Data System (ADS)

    Poorvasha, S.; Lakshmi, B.

    2018-05-01

    In this paper, RF performance analysis of InAs-based double gate (DG) tunnel field effect transistors (TFETs) is investigated in both qualitative and quantitative fashion. This investigation is carried out by varying the geometrical and doping parameters of TFETs to extract various RF parameters, unity gain cut-off frequency (f t), maximum oscillation frequency (f max), intrinsic gain and admittance (Y) parameters. An asymmetric gate oxide is introduced in the gate-drain overlap and compared with that of DG TFETs. Higher ON-current (I ON) of about 0.2 mA and less leakage current (I OFF) of 29 fA is achieved for DG TFET with gate-drain overlap. Due to increase in transconductance (g m), higher f t and intrinsic gain is attained for DG TFET with gate-drain overlap. Higher f max of 985 GHz is obtained for drain doping of 5 × 1017 cm‑3 because of the reduced gate-drain capacitance (C gd) with DG TFET with gate-drain overlap. In terms of Y-parameters, gate oxide thickness variation offers better performance due to the reduced values of C gd. A second order numerical polynomial model is generated for all the RF responses as a function of geometrical and doping parameters. The simulation results are compared with this numerical model where the predicted values match with the simulated values. Project supported by the Department of Science and Technology, Government of India under SERB Scheme (No. SERB/F/2660).

  2. Novel attributes of AlGaN/AlN/GaN/SiC HEMTs with the multiple indented channel

    NASA Astrophysics Data System (ADS)

    Orouji, Ali A.; Ghaffari, Majid

    2015-11-01

    In this paper, a high performance AlGaN/AlN/GaN/SiC High Electron Mobility Transistor (HEMT) with the multiple indented channel (MIC-HEMT) is proposed. The main focus of the proposed structure is based on reduction of the space around the gate, stop of the spread of the depletion region around the source-drain, and decrement of the thickness of the channel between the gate and drain. Therefore, the breakdown voltage increases, meanwhile the elimination of the gate depletion layer extension to source/drain decreases the gate-source and gate-drain capacitances. The optimized results reveal that the breakdown voltage and the drain saturation current increase about 178% and 46% compared with a conventional HEMT (C-HEMT), respectively. Therefore, the maximum output power density is improved by factor 4.1 in comparison with conventional one. Also, the cut-off frequency of 25.2 GHz and the maximum oscillation frequency of 92.1 GHz for the MIC-HEMT are obtained compared to 13 GHz and 43 GHz for that of the C-HEMT and the minimum figure noise decreased consequently of reducing the gate-drain and gate-source capacitances by about 42% and 40%, respectively. The proposed MIC-HEMT shows a maximum stable gain (MSG) exceeding 24.1 dB at 3.1 GHz which the greatest gain is yet reported for HEMTs, showing the potential of this device for high power RF applications.

  3. Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.

    PubMed

    Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2017-04-07

    The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.

  4. Occurrence and Transport of Agricultural Chemicals in Leary Weber Ditch Basin, Hancock County, Indiana, 2003-04

    USGS Publications Warehouse

    Baker, Nancy T.; Stone, Wesley W.; Wilson, John T.; Meyer, Michael T.

    2006-01-01

    Leary Weber Ditch Basin, Hancock County, Indiana, is one of seven first-order basins selected from across the United States as part of the Agricultural Chemicals: Source, Transport, and Fate study conducted by the National Water-Quality Assessment Program of the U.S. Geological Survey. The nationwide study was designed to increase the understanding of the links between the sources of water and agricultural chemicals (nutrients and pesticides) and the transport and fate of these chemicals through the environment. Agricultural chemicals were detected in Leary Weber Ditch and in every associated hydrologic compartment sampled during 2003 and 2004. Pesticides were detected more frequently in samples collected from overland flow and from the ditch itself and less frequently in ground-water samples. The lowest concentrations of pesticides and nutrients were detected in samples of rain, soil water, and ground water. The highest concentrations of pesticides and nutrients were detected in samples of tile-drain water, overland flow, and water from Leary Weber Ditch. Samples collected from the tile drain, overland flow and Leary Weber Ditch soon after chemical applications to the fields and coincident with rainfall and increased streamflow had higher concentrations of pesticides and nutrients than samples collected a longer time after the chemicals were applied. A mass-balance mixing analysis based on potassium concentrations indicated that tile drains are the primary contributor of water to Leary Weber Ditch, but overland flow is also an important contributor during periods of high-intensity rainfall. When maximum rainfall intensity was 0.5 inches per hour or lower, overland flow contributed about 10 percent and tile drains contributed about 90 percent of the flow to Leary Weber Ditch. When maximum rainfall intensity was 0.75 inches per hour or greater, overland flow contributed about 40 percent and tile drains contributed about 60 percent of the flow to the ditch. Ground-water flow to Leary Weber Ditch was negligible. Tile drains are an important agricultural-chemical transport path to Leary Weber Ditch, based on the hydrologic contributions of overland flow and tile drains to the ditch. Overland flow is also an important agricultural-chemical transport pathway during high-intensity rainfall; however, storms with high-intensity rainfall are sporadic throughout the year. Tile drains and the soil water moving to the tile drains are the primary transport pathway for agricultural-chemical transport to Leary Weber Ditch during most storms as well as between storms.

  5. Influence of an anomalous dimension effect on thermal instability in amorphous-InGaZnO thin-film transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kuan-Hsien; Chou, Wu-Ching, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw; Chang, Ting-Chang, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw

    2014-10-21

    This paper investigates abnormal dimension-dependent thermal instability in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Device dimension should theoretically have no effects on threshold voltage, except for in short channel devices. Unlike short channel drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, for devices with either a relatively large channel width or a short channel length, the output drain current decreases instead of saturating with an increase in drain voltage. Moreover, the wider the channel and the shorter the channel length, the larger the threshold voltage and output on-state current degradation that is observed. Because of themore » surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider/shorter channel length devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast I{sub D}-V{sub G} and modulated peak/base pulse time I{sub D}-V{sub D} measurements are utilized to demonstrate the self-heating induced anomalous dimension-dependent threshold voltage variation and on-state current degradation.« less

  6. Integrated modeling of storm drain and natural channel networks for real-time flash flood forecasting in large urban areas

    NASA Astrophysics Data System (ADS)

    Habibi, H.; Norouzi, A.; Habib, A.; Seo, D. J.

    2016-12-01

    To produce accurate predictions of flooding in urban areas, it is necessary to model both natural channel and storm drain networks. While there exist many urban hydraulic models of varying sophistication, most of them are not practical for real-time application for large urban areas. On the other hand, most distributed hydrologic models developed for real-time applications lack the ability to explicitly simulate storm drains. In this work, we develop a storm drain model that can be coupled with distributed hydrologic models such as the National Weather Service Hydrology Laboratory's Distributed Hydrologic Model, for real-time flash flood prediction in large urban areas to improve prediction and to advance the understanding of integrated response of natural channels and storm drains to rainfall events of varying magnitude and spatiotemporal extent in urban catchments of varying sizes. The initial study area is the Johnson Creek Catchment (40.1 km2) in the City of Arlington, TX. For observed rainfall, the high-resolution (500 m, 1 min) precipitation data from the Dallas-Fort Worth Demonstration Network of the Collaborative Adaptive Sensing of the Atmosphere radars is used.

  7. Retention of Ag-specific memory CD4+ T cells in the draining lymph node indicates lymphoid tissue resident memory populations.

    PubMed

    Marriott, Clare L; Dutton, Emma E; Tomura, Michio; Withers, David R

    2017-05-01

    Several different memory T-cell populations have now been described based upon surface receptor expression and migratory capabilities. Here we have assessed murine endogenous memory CD4 + T cells generated within a draining lymph node and their subsequent migration to other secondary lymphoid tissues. Having established a model response targeting a specific peripheral lymph node, we temporally labelled all the cells within draining lymph node using photoconversion. Tracking of photoconverted and non-photoconverted Ag-specific CD4 + T cells revealed the rapid establishment of a circulating memory population in all lymph nodes within days of immunisation. Strikingly, a resident memory CD4 + T cell population became established in the draining lymph node and persisted for several months in the absence of detectable migration to other lymphoid tissue. These cells most closely resembled effector memory T cells, usually associated with circulation through non-lymphoid tissue, but here, these cells were retained in the draining lymph node. These data indicate that lymphoid tissue resident memory CD4 + T-cell populations are generated in peripheral lymph nodes following immunisation. © 2017 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Analytical model of nanoscale junctionless transistors towards controlling of short channel effects through source/drain underlap and channel thickness engineering

    NASA Astrophysics Data System (ADS)

    Roy, Debapriya; Biswas, Abhijit

    2018-01-01

    We develop a 2D analytical subthreshold model for nanoscale double-gate junctionless transistors (DGJLTs) with gate-source/drain underlap. The model is validated using well-calibrated TCAD simulation deck obtained by comparing experimental data in the literature. To analyze and control short-channel effects, we calculate the threshold voltage, drain induced barrier lowering (DIBL) and subthreshold swing of DGJLTs using our model and compare them with corresponding simulation value at channel length of 20 nm with channel thickness tSi ranging 5-10 nm, gate-source/drain underlap (LSD) values 0-7 nm and source/drain doping concentrations (NSD) ranging 5-12 × 1018 cm-3. As tSi reduces from 10 to 5 nm DIBL drops down from 42.5 to 0.42 mV/V at NSD = 1019 cm-3 and LSD = 5 nm in contrast to decrement from 71 to 4.57 mV/V without underlap. For a lower tSiDIBL increases marginally with increasing NSD. The subthreshold swing reduces more rapidly with thinning of channel thickness rather than increasing LSD or decreasing NSD.

  9. Storm drains are sources of human fecal pollution during dry weather in three urban southern California watersheds.

    PubMed

    Sercu, Bram; Van De Werfhorst, Laurie C; Murray, Jill; Holden, Patricia A

    2009-01-15

    Coastal urbanized areas in Southern California experience frequent beach water quality warnings in summer due to high concentrations of fecal indicator bacteria (FIB). Remediation can be difficult, as sources are often unknown. During two summers, we sampled three urbanized watersheds in Santa Barbara, CA at sites with historically high FIB concentrations to determine if human fecal matter was influencing water quality. By quantification of a human-specific Bacteroides marker (HBM), human waste was evidenced throughout both transects, and concentrations were highest in the discharges of several flowing storm drains. The HBM concentrations in storm drain discharges varied by up to 5 orders of magnitude on the same day. While the exact points of entry into the storm drain systems were not definitively determined, further inspection of the drain infrastructure suggested exfiltrating sanitary sewers as possible sources. The HBM and FIB concentrations were not consistently correlated, although the exclusive occurrence of high HBM concentrations with high FIB concentrations warrants the use of FIB analyses for a first tier of sampling. The association of human fecal pollution with dry weather drainage could be a window into a larger problem for other urbanized coastal areas with Mediterranean-type climates.

  10. Monte Carlo simulations of spin transport in a strained nanoscale InGaAs field effect transistor

    NASA Astrophysics Data System (ADS)

    Thorpe, B.; Kalna, K.; Langbein, F. C.; Schirmer, S.

    2017-12-01

    Spin-based logic devices could operate at a very high speed with a very low energy consumption and hold significant promise for quantum information processing and metrology. We develop a spintronic device simulator by combining an in-house developed, experimentally verified, ensemble self-consistent Monte Carlo device simulator with spin transport based on a Bloch equation model and a spin-orbit interaction Hamiltonian accounting for Dresselhaus and Rashba couplings. It is employed to simulate a spin field effect transistor operating under externally applied voltages on a gate and a drain. In particular, we simulate electron spin transport in a 25 nm gate length In0.7Ga0.3As metal-oxide-semiconductor field-effect transistor with a CMOS compatible architecture. We observe a non-uniform decay of the net magnetization between the source and the gate and a magnetization recovery effect due to spin refocusing induced by a high electric field between the gate and the drain. We demonstrate a coherent control of the polarization vector of the drain current via the source-drain and gate voltages, and show that the magnetization of the drain current can be increased twofold by the strain induced into the channel.

  11. Retrograde Instillation of Methylene Blue in the Difficult Diagnosis of BPF

    PubMed Central

    Ravenna, F.; Feo, C.; Calia, N.; Avoscan, C.; Barbetta, C.; Cavallesco, G. N.

    2012-01-01

    We report two cases in which we were able to diagnose bronchopleural fistula through retrograde methylene blue instillation during bronchoscopy. In the first case, methylene blue was injected through an abdominal drain, followed by air instillation and detected in the left bronchial tree, demonstrating the presence of a fistula in the lingula's bronchus. In the second case, methylene blue was injected into a pleural drain, through a breach on a surgical suture and detected in the right bronchial tree, demonstrating the presence of a fistula in the right inferior bronchus. The retrograde instillation of methylene blue, through a drain in the abdomen or the thoracic wall, is a safe, cheap, and practical method that allows the bronchoscopist to identify the presence of a fistula and, more importantly, to identify the exact point on the bronchial tree where a fistula is located. This provides the possibility of sealing the fistula with a variety of devices. It is our opinion that this procedure should be considered a primary method of diagnosis when a bronchopleural fistula is suspected and a drain on the thoracic or abdominal wall is positioned such that effusions are able to drain. PMID:23091498

  12. Retrograde Instillation of Methylene Blue in the Difficult Diagnosis of BPF.

    PubMed

    Ravenna, F; Feo, C; Calia, N; Avoscan, C; Barbetta, C; Cavallesco, G N

    2012-01-01

    We report two cases in which we were able to diagnose bronchopleural fistula through retrograde methylene blue instillation during bronchoscopy. In the first case, methylene blue was injected through an abdominal drain, followed by air instillation and detected in the left bronchial tree, demonstrating the presence of a fistula in the lingula's bronchus. In the second case, methylene blue was injected into a pleural drain, through a breach on a surgical suture and detected in the right bronchial tree, demonstrating the presence of a fistula in the right inferior bronchus. The retrograde instillation of methylene blue, through a drain in the abdomen or the thoracic wall, is a safe, cheap, and practical method that allows the bronchoscopist to identify the presence of a fistula and, more importantly, to identify the exact point on the bronchial tree where a fistula is located. This provides the possibility of sealing the fistula with a variety of devices. It is our opinion that this procedure should be considered a primary method of diagnosis when a bronchopleural fistula is suspected and a drain on the thoracic or abdominal wall is positioned such that effusions are able to drain.

  13. Accuracy of surgical wound drainage measurements: an analysis and comparison.

    PubMed

    Yue, Brian; Nizzero, Danielle; Zhang, Chunxiao; van Zyl, Natasha; Ting, Jeannette

    2015-05-01

    Surgical drain tube readings can influence the clinical management of the post-operative patient. The accuracy of these readings has not been documented in the current literature and this experimental study aims to address this paucity. Aliquots (10, 25, 40 and 90 mL) of black tea solution prepared to mimic haemoserous fluid were injected into UnoVac, RedoVac and Jackson-Pratt drain tubes. Nursing and medical staff from a tertiary hospital were asked to estimate drain volumes by direct observation; analysis of variance was performed on the results and significance level was set at 0.05. Doctors and nurses are equally accurate in estimating drain tube volumes. Jackson-Pratt systems were found to be the most accurate for intermediate volumes of 25 and 40 mL. For extreme of volumes (both high and low), all drainage systems were inaccurate. This study suggests that for intermediate volumes (25 and 40 mL), Jackson-Pratt is the drainage system of choice. The accuracy of volume measurement is diminished at the extremes of drain volumes; emptying of drainage systems is recommended to avoid overfilling of drainage systems. © 2014 Royal Australasian College of Surgeons.

  14. Electrical characteristics of tunneling field-effect transistors with asymmetric channel thickness

    NASA Astrophysics Data System (ADS)

    Kim, Jungsik; Oh, Hyeongwan; Kim, Jiwon; Meyyappan, M.; Lee, Jeong-Soo

    2017-02-01

    Effects of using asymmetric channel thickness in tunneling field-effect transistors (TFET) are investigated in sub-50 nm channel regime using two-dimensional (2D) simulations. As the thickness of the source side becomes narrower in narrow-source wide-drain (NSWD) TFETs, the threshold voltage (V th) and the subthreshold swing (SS) decrease due to enhanced gate controllability of the source side. The narrow source thickness can make the band-to-band tunneling (BTBT) distance shorter and induce much higher electric field near the source junction at the on-state condition. In contrast, in a TFET with wide-source narrow-drain (WSND), the SS shows almost constant values and the V th slightly increases with narrowing thickness of the drain side. In addition, the ambipolar current can rapidly become larger with smaller thickness on the drain side because of the shorter BTBT distance and the higher electric-field at the drain junction. The on-current of the asymmetric channel TFET is lower than that of conventional TFETs due to the volume limitation of the NSWD TFET and high series resistance of the WSND TFET. The on-current is almost determined by the channel thickness of the source side.

  15. Top-gated chemical vapor deposition grown graphene transistors with current saturation.

    PubMed

    Bai, Jingwei; Liao, Lei; Zhou, Hailong; Cheng, Rui; Liu, Lixin; Huang, Yu; Duan, Xiangfeng

    2011-06-08

    Graphene transistors are of considerable interest for radio frequency (rf) applications. In general, transistors with large transconductance and drain current saturation are desirable for rf performance, which is however nontrivial to achieve in graphene transistors. Here we report high-performance top-gated graphene transistors based on chemical vapor deposition (CVD) grown graphene with large transconductance and drain current saturation. The graphene transistors were fabricated with evaporated high dielectric constant material (HfO(2)) as the top-gate dielectrics. Length scaling studies of the transistors with channel length from 5.6 μm to 100 nm show that complete current saturation can be achieved in 5.6 μm devices and the saturation characteristics degrade as the channel length shrinks down to the 100-300 nm regime. The drain current saturation was primarily attributed to drain bias induced shift of the Dirac points. With the selective deposition of HfO(2) gate dielectrics, we have further demonstrated a simple scheme to realize a 300 nm channel length graphene transistors with self-aligned source-drain electrodes to achieve the highest transconductance of 250 μS/μm reported in CVD graphene to date.

  16. Development of Charge Drain Coatings: Final CRADA Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elam, Jeffrey W.

    2017-01-17

    The primary goal of this CRADA project was to develop and optimize tunable resistive coatings prepared by atomic layer deposition (ALD) for use as charge-drain coatings on the KLA-Tencor digital pattern generators (DPGs).

  17. 46 CFR 169.565 - Fixed carbon dioxide system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., protected against injury. (5) Drains and dirt traps must be fitted where necessary to prevent accumulation of dirt or moisture. Each drain and dirt trap must be located in accessible locations but not in...

  18. National Dam Safety Program, Mill Pond Dam (Inventory Number NY 368), Lake Champlain Basin, Essex County, New York. Phase I Inspection Report

    DTIC Science & Technology

    1980-08-28

    displaced timbers on the downstream face, replace broken timbers, repair of the valve on the drain, and repair of the spalling concrete on the wingwall which...repair of the valve on the drain, and repair of the spalling concrete on the wingwall which extends downstream of the north abutment. In addition, a...long. The gatehouse at the northern end of the dam contains the control mechanism for a valve which regulates flow at the reservoir drain inlet, an 84

  19. Internal combuston engine having separated cylinder head oil drains and crankcase ventilation passages

    DOEpatents

    Boggs, David Lee; Baraszu, Daniel James; Foulkes, David Mark; Gomes, Enio Goyannes

    1998-01-01

    An internal combustion engine includes separated oil drain-back and crankcase ventilation passages. The oil drain-back passages extend from the cylinder head to a position below the top level of oil in the engine's crankcase. The crankcase ventilation passages extend from passages formed in the main bearing bulkheads from positions above the oil level in the crankcase and ultimately through the cylinder head. Oil dams surrounding the uppermost portions of the crankcase ventilation passages prevent oil from running downwardly through the crankcase ventilation passages.

  20. Internal combuston engine having separated cylinder head oil drains and crankcase ventilation passages

    DOEpatents

    Boggs, D.L.; Baraszu, D.J.; Foulkes, D.M.; Gomes, E.G.

    1998-12-29

    An internal combustion engine includes separated oil drain-back and crankcase ventilation passages. The oil drain-back passages extend from the cylinder head to a position below the top level of oil in the engine`s crankcase. The crankcase ventilation passages extend from passages formed in the main bearing bulkheads from positions above the oil level in the crankcase and ultimately through the cylinder head. Oil dams surrounding the uppermost portions of the crankcase ventilation passages prevent oil from running downwardly through the crankcase ventilation passages. 4 figs.

  1. Lower San Fernando corrugated metal pipe failure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardet, J.P.; Davis, C.A.

    1995-12-31

    During the January 17, 1994, Northridge earthquake, a 2.4 m diameter corrugated metal pipe was subjected to 90 m of extensive lateral crushing failure at the Lower San Fernando Dam. The dam and outlet works were reconstructed after the 1971 San Fernando Earthquake. In 1994, the dam underwent liquefaction upstream of the reconstructed berm. The pipe collapsed on the west side of the liquefied zone and a large sinkhole formed over the drain line. The failure of this drain line provides a unique opportunity to study the seismic response of buried drains and culverts.

  2. Remaining Sites Verification Package for the 118-C-3:3, 105-C French Drains, Waste Site Reclassification Form 2006-016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. A. Carlson

    2006-04-24

    The 118-C-3:3 french drains received condensate from the steam heating system in the 105-C Reactor Building. The 118-C-3:3 french drain meets the remedial action objectives specified in the Remaining Sites ROD. The results demonstrate that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  3. High soil solution carbon and nitrogen concentrations in a drained Atlantic bog are reduced to natural levels by 10 years of rewetting

    NASA Astrophysics Data System (ADS)

    Frank, S.; Tiemeyer, B.; Gelbrecht, J.; Freibauer, A.

    2014-04-01

    Anthropogenic drainage of peatlands releases additional greenhouse gases to the atmosphere, and dissolved carbon (C) and nutrients to downstream ecosystems. Rewetting drained peatlands offers a possibility to reduce nitrogen (N) and C losses. In this study, we investigate the impact of drainage and rewetting on the cycling of dissolved C and N as well as on dissolved gases, over a period of 1 year and a period of 4 months. We chose four sites within one Atlantic bog complex: a near-natural site, two drained grasslands with different mean groundwater levels and a former peat cutting area rewetted 10 years ago. Our results clearly indicate that long-term drainage has increased the concentrations of dissolved organic carbon (DOC), ammonium, nitrate and dissolved organic nitrogen (DON) compared to the near-natural site. DON and ammonium contributed the most to the total dissolved nitrogen. Nitrate concentrations below the mean groundwater table were negligible. The concentrations of DOC and N species increased with drainage depth. In the deeply-drained grassland, with a mean annual water table of 45 cm below surface, DOC concentrations were twice as high as in the partially rewetted grassland with a mean annual water table of 28 cm below surface. The deeply drained grassland had some of the highest-ever observed DOC concentrations of 195.8 ± 77.3 mg L-1 with maximum values of >400 mg L-1. In general, dissolved organic matter (DOM) at the drained sites was enriched in aromatic moieties and showed a higher degradation status (lower DOC to DON ratio) compared to the near-natural site. At the drained sites, the C to N ratios of the uppermost peat layer were the same as of DOM in the peat profile. This suggests that the uppermost degraded peat layer is the main source of DOM. Nearly constant DOM quality through the profile furthermore indicated that DOM moving downwards through the drained sites remained largely biogeochemically unchanged. Unlike DOM concentration, DOM quality and dissolved N species distribution were similar in the two grasslands and thus unaffected by the drainage depth. Methane production during the winter months at the drained sites was limited to the subsoil, which was quasi-permanently water saturated. The recovery of the water table in the winter months led to the production of nitrous oxide around mean water table depth at the drained sites. The rewetted and the near-natural site had comparable DOM quantity and quality (DOC to DON ratio and aromaticity). 10 years after rewetting quasi-pristine biogeochemical conditions have been re-established under continuously water logged conditions in the former peat cut area. Only the elevated dissolved methane and ammonium concentrations reflected the former disturbance by drainage and peat extraction. Rewetting via polder technique seems to be an appropriate way to revitalize peatlands on longer timescales and to improve the water quality of downstream water bodies.

  4. Trends and transformation of nutrients and pesticides in a Coastal Plain aquifer system, United States

    USGS Publications Warehouse

    Denver, J.M.; Tesoriero, A.J.; Barbaro, J.R.

    2010-01-01

    Four local-scale sites in areas with similar corn (Zea mays L.) and soybean [Glycine max (L.) Merr.] agriculture were studied to determine the effects of different hydrogeologic settings of the Northern Atlantic Coastal Plain (NACP) on the transport of nutrients and pesticides in groundwater. Settings ranged from predominantly well-drained soils overlying thick, sandy surficial aquifers to predominantly poorly drained soils with complex aquifer stratigraphy and high organic matter content. Apparent age of groundwater, dissolved gases, N isotopes, major ions, selected pesticides and degradates, and geochemical environments in groundwater were studied. Agricultural chemicals were the source of most dissolved ions in groundwater. Specific conductance was strongly correlated with reconstructed nitrate (the sum of N in nitrate and N gas) (R2 = 0.81, p < 0.0001), and is indicative of the relative degree of agricultural effects on groundwater. Trends in nitrate were primarily related to changes in manure and fertilizer use at the well-drained sites where aquifer conditions were consistently oxic. Nitrate was present in young groundwater but completely removed over time through denitrification at the poorly drained sites where there were variations in chemical input and in geochemical environment. Median concentrations of atrazine (6-chloro-N-ethyl-N'-(1- methylethyl)-1,3,5-triazine-2,4-diamine), metolachlor (2-chloro-N-(2-ethyl-6- methylphenyl)-N-(2-methoxy-1-methylethyl)acetamide), and some of their common degradates were higher at well-drained sites than at poorly drained sites, with concentrations of degradates generally higher than those of the parent compounds at all sites. An increase in the percentage of deethylatrazine to total atrazine over time at one well-drained site may be related to changes in manure application. Copyright ?? 2010 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  5. Investigation of the effects of slow-release fertilizer and struvite in biodegradation in filter drains and potential application of treated water in irrigation of road verges.

    PubMed

    Theophilus, Stephen C; Mbanaso, Fredrick U; Nnadi, Ernest O; Onyedeke, Kingsley T

    2017-11-14

    Filter drains are usually laid along the margins of highways. Highway runoffs are polluted with hydrocarbons and high levels of total dissolved solids. Therefore, effective pollution removal mechanism is necessary in order to avoid contamination of surrounding soils and groundwater. Biodegradation is amongst pollution removal mechanisms in filter drains, but it is a relatively slow process which is dependent on wide range of factors including the type of pollutant and availability of nutrients. This paper reports on a study conducted to investigate the impact of slow-release fertilizer and struvite in enhancement of biodegradation of hydrocarbon in filter drains. Filter drain models incorporated with geotextile were challenged with cumulative oil loading of 178 mg/m 2 /week with a view to comparing the efficiency of these two nutrient sources under high oil pollution loading and realistic rainfall conditions of 13 mm/week. Nutrients and street dust were applied at one-off rate of 17 g/m 2 and 1.55 g/rig to provide nutrient enhancement and simulate field conditions respectively. The impact of the nutrients was studied by monitoring bacterial and fungal growth using nutrient agar, Rose Bengal Agar media and CO2 evolution. EC, pH, heavy metals, TPH, elemental analysis and SAR were used to investigate water quality of effluent of filter drains for potential application as irrigation fluid for trees and flowers planted on road verges. The results show that nutrient application encouraged microbial activities and enhanced biodegradation rates with differences in type of nutrient applied. Also, it was observed that incorporation of geotextiles in filter drains improved pollution retention efficiency and there is a potential opportunity for utilization of struvite in SuDS systems as sustainable nutrient source.

  6. Water management controls net carbon exchange in drained and flooded agricultural peatlands in the Sacramento-San Joaquin Delta, CA

    NASA Astrophysics Data System (ADS)

    Hatala, J.; Detto, M.; Sonnentag, O.; Verfaillie, J. G.; Baldocchi, D. D.

    2011-12-01

    Draining peatlands for agricultural cultivation creates an ecosystem shift with some of the fastest rates and largest magnitudes of carbon loss attributable to land-use change, yet peatland drainage is practiced around the world due to the high economic benefit of fertile soil. The Sacramento-San Joaquin Delta in California was drained at the end of the 19th century for agriculture and human settlement, and as a result, has lost 5-8m of peat soil due to oxidation. To reverse subsidence and capture carbon, there is increasing interest in converting drained agricultural land-uses back to flooded conditions to inhibit further peat oxidation. However, this method remains relatively untested at the landscape-scale. This study analyzed the short-term effects of drained to flooded land-use conversion on the balance of carbon, water, and energy over two years at two landscapes in the Delta. We used the eddy covariance method to compare CO2, CH4, H2O, and energy fluxes under the same meteorological conditions in two different land-use types: a drained pasture grazed by cattle, and a flooded newly-converted rice paddy. By analyzing differences in the fluxes from these two land-use types we determined that water management and differences in the plant canopy both play a fundamental role in governing the seasonal pattern and the annual budgets of CO2 and CH4 fluxes at these two sites. While the pasture was a source of carbon to the atmosphere in both years, the rice paddy captured carbon through NEE, even after considering losses from CH4. Especially during the fallow winter months, flooding the soil at the rice paddy inhibited loss of CO2 through ecosystem respiration when compared with the carbon exchange from the drained pasture.

  7. Automated detection of external ventricular and lumbar drain-related meningitis using laboratory and microbiology results and medication data.

    PubMed

    van Mourik, Maaike S M; Groenwold, Rolf H H; Berkelbach van der Sprenkel, Jan Willem; van Solinge, Wouter W; Troelstra, Annet; Bonten, Marc J M

    2011-01-01

    Monitoring of healthcare-associated infection rates is important for infection control and hospital benchmarking. However, manual surveillance is time-consuming and susceptible to error. The aim was, therefore, to develop a prediction model to retrospectively detect drain-related meningitis (DRM), a frequently occurring nosocomial infection, using routinely collected data from a clinical data warehouse. As part of the hospital infection control program, all patients receiving an external ventricular (EVD) or lumbar drain (ELD) (2004 to 2009; n = 742) had been evaluated for the development of DRM through chart review and standardized diagnostic criteria by infection control staff; this was the reference standard. Children, patients dying <24 hours after drain insertion or with <1 day follow-up and patients with infection at the time of insertion or multiple simultaneous drains were excluded. Logistic regression was used to develop a model predicting the occurrence of DRM. Missing data were imputed using multiple imputation. Bootstrapping was applied to increase generalizability. 537 patients remained after application of exclusion criteria, of which 82 developed DRM (13.5/1000 days at risk). The automated model to detect DRM included the number of drains placed, drain type, blood leukocyte count, C-reactive protein, cerebrospinal fluid leukocyte count and culture result, number of antibiotics started during admission, and empiric antibiotic therapy. Discriminatory power of this model was excellent (area under the ROC curve 0.97). The model achieved 98.8% sensitivity (95% CI 88.0% to 99.9%) and specificity of 87.9% (84.6% to 90.8%). Positive and negative predictive values were 56.9% (50.8% to 67.9%) and 99.9% (98.6% to 99.9%), respectively. Predicted yearly infection rates concurred with observed infection rates. A prediction model based on multi-source data stored in a clinical data warehouse could accurately quantify rates of DRM. Automated detection using this statistical approach is feasible and could be applied to other nosocomial infections.

  8. A prospective randomised study to compare the utility and outcomes of subdural and subperiosteal drains for the treatment of chronic subdural haematoma.

    PubMed

    Kaliaperumal, Chandrasekaran; Khalil, Ayman; Fenton, Eoin; Okafo, Uchenna; Kaar, George; O'Sullivan, Michael; Marks, Charles

    2012-11-01

    The usage of a drain following evacuation of a chronic subdural haematoma (CSDH) is known to reduce recurrence. In this study we aim to compare the clinical outcomes and recurrence rate of utilising two different types of drains (subperiosteal and subdural drain) following drainage of a CSDH. Prospective randomised single-centre study analysing 50 patients who underwent CSDH treatment. Two types of drains, subperiosteal (SPD) and subdural (SDD), were utilised on consecutive alternate patients following burr-hole craniostomy, with a total of 25 patients in each group. The drains were left in for 48-h duration and then removed. The modified Rankin Scale (mRS) was used for outcome measurement at 3 and 6 months. Data analysis was performed by unpaired t test with Welch's correction. It was observed that none of the patients in either group had haematoma recurrence during a 6-month follow-up, and a significant difference in outcome was noted at 6 months (p = 0.0118) more than at 3 months (p = 0.0493) according to the statistical analysis. Postoperative seizure and inadvertent placement of the subdural drain into the brain parenchyma were the two complications noted in this study. Anticoagulant use prior to the surgery did not affect the outcome in either group. We conclude there was no recurrence of CSDH utilising the SDD and SPD following burr-hole craniostomy. The mRS measurement at the 6-month follow-up was found to be statistically significant, with better outcomes with utilisation of the SPD. The SPD may thus prove to be more beneficial than the SDD in the treatment of CSDH. A multi-centre study with a larger group of patients is recommended to reinforce the results from our study.

  9. Dissolved organic carbon in runoff and tile-drain water under corn and forage fertilized with hog manure.

    PubMed

    Royer, Isabelle; Angers, Denis A; Chantigny, Martin H; Simard, Régis R; Cluis, Daniel

    2007-01-01

    Dissolved organic carbon (DOC) export from soils can play a significant role in soil C cycling and in nutrient and pollutant transport. However, information about DOC losses from agricultural soils as influenced by management practices is scarce. We compared the effects of mineral fertilizer (MF) and liquid hog manure (LHM) applications on the concentration and molecular size of DOC released in runoff and tile-drain water under corn (Zea mays L.) and forage cropping systems. Runoff and tile-drain water samples were collected during a 2-mo period (October to December 1998) and DOC concentration was measured. Characterization of DOC was performed by tangential ultrafiltration with nominal cut-offs at 3 and 100 kDa. Mean concentration of DOC in runoff water (12.7 mg DOC L(-1)) was higher than in tile-drain water (6.5 mg DOC L(-1)). Incorporation of corn residues increased the DOC concentration by 6- to 17-fold in surface runoff, but this effect was short-lived. In runoff water, the relative size of the DOC molecules increased when corn residues and LHM were applied probably due to partial microbial breakdown of these organic materials and to a faster decomposition or preferential adsorption of the small molecules. The DOC concentration in tile-drain water was slightly higher under forage (7.5 mg DOC L(-1)) than under corn (5.4 mg DOC L(-1)) even though the application rates of LHM were higher in corn plots. We suggest that preferential flow facilitated the migration of DOC to tile drains in forage plots. In conclusion, incorporation of corn residues and LHM increased the concentration of DOC and the relative size of the molecules in surface runoff water, whereas DOC in tile-drain water was mostly influenced by the cropping system with relatively more DOC and larger molecules under forage than corn.

  10. Closed-Suction Drains After Subcutaneous Mastectomy for Gynecomastia: Do They Reduce Complications? A Different Approach.

    PubMed

    Boccara, David; Serror, Kevin; Malca, Nathaniel; Chaouat, Marc; Mimoun, Maurice

    2018-06-01

    We read the manuscript entitled "Closed-suction drains after subcutaneous mastectomy for gynecomastia: do they reduce complications? » published by Chao et al. (Aesthetic Plast Surg, 2017. https://doi.org/10.1007/s00266-017-0959-z ). They have concluded that drains may reduce rates of seromas requiring needle aspiration after surgical treatment, but also that there are several adverse effects of drains: patients' discomfort, anxiety, cost and additional clinic visits. They also recalled several limitations: (1) bias in terms of surgeon decision to place a drain, (2) nuances in technique. Here we want to discuss our different technique of drainage. To prevent all the disadvantages, we have chosen to replace closed-suction drains with silicone blades and a wide scar opening at the level of the periareolar scar. We carried out a retrospective study in our department in 2016. This series consisted of 83 patients (153 breasts) aged 26.7 years of age (15-67), with an average BMI of 28.6 (19.5-39). All were followed during the 12 months postoperatively. We considered here only grade 1-2a gynecomastia with palpable fibrous glandular tissue. The surgical procedure consisted of initial liposuction, then open surgical excision via the periareolar approach. We did not notice any seroma or collection requiring intervention. However, 4 patients (4/153; 2.6%) had hematomas requiring intervention the day after surgery. Our technique presents a lot of advantages, reduced length of stay in the hospital, costs from drain site care and clinic visits, patients' discomfort, and antibiotic prescriptions. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  11. Sub-xyphoid pleural drain as a determinant of functional capacity and clinical results after off-pump coronary artery bypass surgery: a randomized clinical trial.

    PubMed

    Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J

    2014-09-01

    The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P <0.05). Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P <0.05), lower pain scores (P <0.0001), and shorter orotracheal intubation and hospitalization lengths (P <0.001). Sub-xyphoid pleural drain determined better functional capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Poison-Proof Your Home: One Room at a Time Checklist

    MedlinePlus

    ... hazardous products like bleach, bug spray, drain cleaners, ammonia, floor wax, furniture polish, and disinfectants up high ... food. Are all kitchen cleanser, drain opener, and ammonia substances in their original containers? Yes ■ Keep all ...

  13. Prefabricated vertical drains, vol. I : engineering guidelines.

    DOT National Transportation Integrated Search

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal tion of prefabricated vertical drains to accelerate consolidation of soils. The contents represent the Consultant's interpretation of the state-of-the-art as of August...

  14. Environmental Education: Non-point Source Pollution

    EPA Pesticide Factsheets

    This activity is designed to demonstrate to students what an average storm drain collects during a rainfall event and how the water from storm drains can impact the water quality and aquatic environments of local streams, rivers, and bays.

  15. Media filter drain : modified design evaluation.

    DOT National Transportation Integrated Search

    2014-09-01

    The media filter drain (MFD), a stormwater water quality treatment best management practice, consists of media made up of : aggregate, perlite, gypsum and dolomite in a trench located along roadway shoulders with gravel and vegetative pre-filtering f...

  16. An analytical drain current model for symmetric double-gate MOSFETs

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Huang, Gongyi; Lin, Wei; Xu, Chuanzhong

    2018-04-01

    An analytical surface-potential-based drain current model of symmetric double-gate (sDG) MOSFETs is described as a SPICE compatible model in this paper. The continuous surface and central potentials from the accumulation to the strong inversion regions are solved from the 1-D Poisson's equation in sDG MOSFETs. Furthermore, the drain current is derived from the charge sheet model as a function of the surface potential. Over a wide range of terminal voltages, doping concentrations, and device geometries, the surface potential calculation scheme and drain current model are verified by solving the 1-D Poisson's equation based on the least square method and using the Silvaco Atlas simulation results and experimental data, respectively. Such a model can be adopted as a useful platform to develop the circuit simulator and provide the clear understanding of sDG MOSFET device physics.

  17. Back bias induced dynamic and steep subthreshold swing in junctionless transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parihar, Mukta Singh; Kranti, Abhinav, E-mail: akranti@iiti.ac.in

    In this work, we analyze back bias induced steep and dynamic subthreshold swing in junctionless double gate transistors operated in the asymmetric mode. This impact ionization induced dynamic subthreshold swing is explained in terms of the ratio between minimum hole concentration and peak electron concentration, and the dynamic change in the location of the conduction channel with applied front gate voltage. The reason for the occurrence of impact ionization at sub-bandgap drain voltages in silicon junctionless transistors is also accounted for. The optimum junctionless transistor operating at a back gate bias of −0.9 V, achieves over 5 orders of change inmore » drain current at a gate overdrive of 200 mV and drain bias of 1 V. These results for junctionless transistors are significantly better than those exhibited by silicon tunnel field effect transistors operating at the same drain bias.« less

  18. Bottom-gate poly-Si thin-film transistors by nickel silicide seed-induced lateral crystallization with self-aligned lightly doped layer

    NASA Astrophysics Data System (ADS)

    Lee, Sol Kyu; Seok, Ki Hwan; Chae, Hee Jae; Lee, Yong Hee; Han, Ji Su; Jo, Hyeon Ah; Joo, Seung Ki

    2017-03-01

    We report a novel method to reduce source and drain (S/D) resistances, and to form a lightly doped layer (LDL) of bottom-gate polycrystalline silicon (poly-Si) thin-film transistors (TFTs). For application in driving TFTs, which operate under high drain voltage condition, poly-Si TFTs are needed in order to attain reliability against hot-carriers as well as high field-effect mobility (μFE). With an additional doping on the p+ Si layer, sheet resistance on S/D was reduced by 37.5% and an LDL was introduced between the channel and drain. These results contributed to not only a lower leakage current and gate-induced drain leakage, but also high immunity of kink-effect and hot-carrier stress. Furthermore, the measured electrical characteristics exhibited a steep subthreshold slope of 190 mV/dec and high μFE of 263 cm2/Vs.

  19. Short-term effects of salinity reduction and drainage on salt-marsh biogeochemical cycling and Spartina (Cordgrass) production

    USGS Publications Warehouse

    Portnoy, J.W.; Valiela, I.

    1997-01-01

    To assess the biogeochemical effects of tidal restrictions on salt-marsh sulfur cycling and plant growth, cores of short-form Spartina alterniflora peat were desalinated and kept either waterlogged or drained in greenhouse microcosms. Changes in net Spartina production, and porewater and solid phase chemistry of treated cores were compared to natural conditions in the field collection site over a 21-mo period. Net production among treatments increased significantly in drained and waterlogged peat compared to field conditions during the first growing season. Constantly high sulfide in waterlogged cores accompanied reduced plant growth. Aeration invigorated growth in drained cores but led to oxidization of sulfide minerals and to lowered pH. During the second growing season, growth declined in the drained treatment, probably because of acidification and decreased dissolved inorganic nitrogen. Results are pertinent to the success of current wetland protection and restoration activities in the coastal zone.

  20. Method and system for reducing device performance degradation of organic devices

    DOEpatents

    Teague, Lucile C.

    2014-09-02

    Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.

  1. Modeling and simulation of enhancement mode p-GaN Gate AlGaN/GaN HEMT for RF circuit switch applications

    NASA Astrophysics Data System (ADS)

    Panda, D. K.; Lenka, T. R.

    2017-06-01

    An enhancement mode p-GaN gate AlGaN/GaN HEMT is proposed and a physics based virtual source charge model with Landauer approach for electron transport has been developed using Verilog-A and simulated using Cadence Spectre, in order to predict device characteristics such as threshold voltage, drain current and gate capacitance. The drain current model incorporates important physical effects such as velocity saturation, short channel effects like DIBL (drain induced barrier lowering), channel length modulation (CLM), and mobility degradation due to self-heating. The predicted I d-V ds, I d-V gs, and C-V characteristics show an excellent agreement with the experimental data for both drain current and capacitance which validate the model. The developed model was then utilized to design and simulate a single-pole single-throw (SPST) RF switch.

  2. Comparison of gate and drain current detection of hydrogen at room temperature with AlGaN /GaN high electron mobility transistors

    NASA Astrophysics Data System (ADS)

    Wang, Hung-Ta; Kang, B. S.; Ren, F.; Fitch, R. C.; Gillespie, J. K.; Moser, N.; Jessen, G.; Jenkins, T.; Dettmer, R.; Via, D.; Crespo, A.; Gila, B. P.; Abernathy, C. R.; Pearton, S. J.

    2005-10-01

    Pt-gated AlGaN /GaN high electron mobility transistors can be used as room-temperature hydrogen gas sensors at hydrogen concentrations as low as 100ppm. A comparison of the changes in drain and gate current-voltage (I-V) characteristics with the introduction of 500ppm H2 into the measurement ambient shows that monitoring the change in drain-source current provides a wider gate voltage operation range for maximum detection sensitivity and higher total current change than measuring the change in gate current. However, over a narrow gate voltage range, the relative sensitivity of detection by monitoring the gate current changes is up to an order of magnitude larger than that of drain-source current changes. In both cases, the changes are fully reversible in <2-3min at 25°C upon removal of the hydrogen from the ambient.

  3. Remaining Sites Verification Package for the 100-F-46, 119-F Stack Sampling French Drain, Waste Site Reclassification Form 2008-021

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. M. Capron

    2008-08-08

    The 100-F-46 french drain consisted of a 1.5 to 3 m long, vertically buried, gravel-filled pipe that was approximately 1 m in diameter. Also included in this waste site was a 5 cm cast-iron pipeline that drained condensate from the 119-F Stack Sampling Building into the 100-F-46 french drain. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do notmore » preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.« less

  4. Chemical and microbiological water quality of subsurface agricultural drains during a field trial of liquid dairy manure effluent application rate and varying tillage practices, Upper Tiffin Watershed, southeastern Michigan

    USGS Publications Warehouse

    Haack, Sheridan Kidd; Duris, Joseph W.

    2008-01-01

    A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational-water-quality single-sample criterion of 235 colony forming units per 100 milliliters in only 3 of 56 samples. Of these three samples, two were collected within 1 day post-LDME application from the treatment receiving 8,000 gal/acre LDME with no tillage (NT8000). The third sample was from the rolling-tine aerator treatment with 4,000 gal/acre LDME application rate after the first significant rainfall. Two wastewater chemicals and two bacterial genes (eaeA and stx1) detected in the LDME, but absent in field blank or pre-application samples, were detected in the 4-hour or 1-day postapplication NT8000 samples. No LDME-associated chemicals were detected in later samples from the NT8000 treatment, and none were detected in samples from other treatments after the first significant rainfall. Results of this field trial were somewhat equivocal with respect to the influence of LDME concentration and tillage practices on subsurface-drain water quality, both immediately after LDME application and in the longer term, after significant rainfall. Interpretation of study findings is limited by the fact that treatments were not replicated, and flow rate or discharge from the subsurface drains was not measured. Nevertheless, study results provide useful information about nutrient and bacteria concentrations in subsurface drains during the non-growing season. In addition, study results demonstrate some potential for the use of chemical and microbiological indicators of LDME transport to subsurface drains.

  5. Necessity of Surgical Site Closed Suction Drain for Pterional Craniotomy

    PubMed Central

    Choi, Su Yong; Yoon, Sung Min; Yoo, Chan Jong; Kim, Young Bo; Kim, Woo Kyung

    2015-01-01

    Objective The aim of this study was to assess the benefit of using a prophylactic surgical site closed suction drain in pterional craniotomy. Materials and Methods A retrospective review was conducted on 607 consecutive patients who underwent a pterional craniotomy for treatment of intracranial anterior circulation aneurysms over a 5-year period. Between January 2000 and December 2004, 607 patients were divided into two groups, those who had a prophylactic suction drain during closure of the surgical site (drain group, DG) and those who did not (non-drain group, NDG). Head computed tomography (CT) was taken routinely on postoperative day (POD) 1, 7, and 14. Patients' demographics, incidence of surgical site complications, and courses of surgical site healing which were evaluated radiologically by the thickness of the surgical site myocutaneous layer, were analyzed between DG and NDG. Results Patients' demographics and characteristics did not differ significantly between the two groups. The head CT showed that the degree of changes in the postoperative surgical site thickness was 148% at POD 1, 209% at POD 7, and 198% at POD 14 in DG, and 118% at POD 1, 152% at POD 7, and 158% at POD 14 in NDG compared to the preoperative value. Postoperative surgical site hematoma was 7.9% (22/274) in DG and 2.4% (8/333) in NDG. Conclusion Prophylactic use of an epidural and/or subgaleal closed suction drain does not appear to be necessary for prevention of postoperative surgical site hematoma as well as for promotion of surgical site healing in pterional craniotomy. PMID:26523255

  6. Improved simulation of poorly drained forests using Biome-BGC.

    PubMed

    Bond-Lamberty, Ben; Gower, Stith T; Ahl, Douglas E

    2007-05-01

    Forested wetlands and peatlands are important in boreal and terrestrial biogeochemical cycling, but most general-purpose forest process models are designed and parameterized for upland systems. We describe changes made to Biome-BGC, an ecophysiological process model, that improve its ability to simulate poorly drained forests. Model changes allowed for: (1) lateral water inflow from a surrounding watershed, and variable surface and subsurface drainage; (2) adverse effects of anoxic soil on decomposition and nutrient mineralization; (3) closure of leaf stomata in flooded soils; and (4) growth of nonvascular plants (i.e., bryophytes). Bryophytes were treated as ectohydric broadleaf evergreen plants with zero stomatal conductance, whose cuticular conductance to CO(2) was dependent on plant water content. Individual model changes were parameterized with published data, and ecosystem-level model performance was assessed by comparing simulated output to field data from the northern BOREAS site in Manitoba, Canada. The simulation of the poorly drained forest model exhibited reduced decomposition and vascular plant growth (-90%) compared with that of the well-drained forest model; the integrated bryophyte photosynthetic response accorded well with published data. Simulated net primary production, biomass and soil carbon accumulation broadly agreed with field measurements, although simulated net primary production was higher than observed data in well-drained stands. Simulated net primary production in the poorly drained forest was most sensitive to oxygen restriction on soil processes, and secondarily to stomatal closure in flooded conditions. The modified Biome-BGC remains unable to simulate true wetlands that are subject to prolonged flooding, because it does not track organic soil formation, water table changes, soil redox potential or anaerobic processes.

  7. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    PubMed

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  8. A novel explicit approach to model bromide and pesticide transport in soils containing macropores

    NASA Astrophysics Data System (ADS)

    Klaus, J.; Zehe, E.

    2011-01-01

    The present study tests whether an explicit treatment of worm burrows is feasible for simulating water flow, bromide and pesticide transport in structured heterogeneous soils. The essence is to represent worm burrows as morphologically connected paths of low flow resistance in the spatially highly resolved model domain. A recent Monte Carlo study (Klaus and Zehe, 2010) revealed that this approach allowed successful reproduction of tile drain event discharge recorded during an irrigation experiment at a tile drained field site. However, several "hillslope architectures" that were all consistent with the available extensive data base allowed a good reproduction of tile drain flow response. Our second objective was thus to find out whether this "equifinality" in spatial model setups may be reduced when including bromide tracer data in the model falsification process. We thus simulated transport of bromide and Isoproturon (IPU) for the 13 spatial model setups, which performed best with respect to reproduce tile drain event discharge, without any further calibration. All model setups allowed a very good prediction of the temporal dynamics of cumulated bromide leaching into the tile drain, while only four of them matched the accumulated water balance and accumulated bromide loss into the tile drain. The number of behavioural model architectures could thus be reduced to four. One of those setups was used for simulating transport of IPU, using different parameter combinations to characterise adsorption according to the Footprint data base. Simulations could, however, only reproduce the observed leaching behaviour, when we allowed for retardation coefficients that were very close to one.

  9. MODULATING STORM DRAIN FLOWS TO REDUCE STREAM POLLUTANT CONCENTRATIONS

    EPA Science Inventory

    Pathogen and toxic chemical concentrations above the chemical and toxicity water quality standards in creeks and rivers pose risks to human health and aquatic ecosystems. Storm drains discharging into these watercourses often contribute significantly to elevating pollutant concen...

  10. Design guidelines for horizontal drains used for slope stabilization.

    DOT National Transportation Integrated Search

    2013-03-01

    The presence of water is one of the most critical factors contributing to the instability of hillslopes. A common : solution to stabilize hillslopes is installation of horizontal drains to decrease the elevation of the water table : surface. Lowering...

  11. 2. VIEW EAST OF HEADGATES AT SPOOL DAM; DRAIN GATE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW EAST OF HEADGATES AT SPOOL DAM; DRAIN GATE MECHANISM AND DAM EDGE AT RIGHT - Willimantic Linen Company, Mill No. 1, Immediately West of South Main Street, North Bank of Willimantic River, Windham, Windham County, CT

  12. Community-based environmental management for malaria control: evidence from a small-scale intervention in Dar es Salaam, Tanzania.

    PubMed

    Castro, Marcia C; Tsuruta, Atsuko; Kanamori, Shogo; Kannady, Khadija; Mkude, Sixbert

    2009-04-08

    Historically, environmental management has brought important achievements in malaria control and overall improvements of health conditions. Currently, however, implementation is often considered not to be cost-effective. A community-based environmental management for malaria control was conducted in Dar es Salaam between 2005 and 2007. After community sensitization, two drains were cleaned followed by maintenance. This paper assessed the impact of the intervention on community awareness, prevalence of malaria infection, and Anopheles larval presence in drains. A survey was conducted in neighbourhoods adjacent to cleaned drains; for comparison, neighbourhoods adjacent to two drains treated with larvicides and two drains under no intervention were also surveyed. Data routinely collected by the Urban Malaria Control Programme were also used. Diverse impacts were evaluated through comparison of means, odds ratios (OR), logistic regression, and time trends calculated by moving averages. Individual awareness of health risks and intervention goals were significantly higher among sensitized neighbourhoods. A reduction in the odds of malaria infection during the post-cleaning period in intervention neighbourhoods was observed when compared to the pre-cleaning period (OR = 0.12, 95% CI 0.05-0.3, p < 0.001). During the post-cleaning period, a higher risk of infection (OR = 1.7, 95% CI 1.1-2.4, p = 0.0069) was observed in neighbourhoods under no intervention compared to intervention ones. Eighteen months after the initial cleaning, one of the drains was still clean due to continued maintenance efforts (it contained no waste materials and the water was flowing at normal velocity). A three-month moving average of the percentage of water habitats in that drain containing pupae and/or Anopheles larvae indicated a decline in larval density. In the other drain, lack of proper resources and local commitment limited success. Although environmental management was historically coordinated by authoritarian/colonial regimes or by industries/corporations, its successful implementation as part of an integrated vector management framework for malaria control under democratic governments can be possible if four conditions are observed: political will and commitment, community sensitization and participation, provision of financial resources for initial cleaning and structural repairs, and inter-sectoral collaboration. Such effort not only is expected to reduce malaria transmission, but has the potential to empower communities, improve health and environmental conditions, and ultimately contribute to poverty alleviation and sustainable development.

  13. Is the blocking of drainage channels in upland peats an effective means of reducing DOC loss at the catchment scale?

    NASA Astrophysics Data System (ADS)

    Turner, Kate; Worrall, Fred

    2010-05-01

    Only 3% of the earths land surface is covered by peatland yet boreal and subarctic peatlands store approximately 15-30% of the World's soil carbon as peat (Limpens et al. 2008). In comparison British bogs store carbon equivalent to 20 years worth of national emissions. The loss of carbon from these areas in the form of dissolved organic carbon (DOC) is increasing and it is expected to have grown by up to 40% by 2018. Extensive drainage of UK peatlands has been associated with dehydration of the peat, an increase in water colour and a loss of carbon storage. It has been considered that the blocking of these drainage channels represents a means of peat restoration and a way of reducing DOC loss. This study aims to assess the effectiveness of this drain blocking at both an individual drain scale and at a larger catchment scale. Gibson et al. (2009) considered the effects of blocking at a solely individual drain scale finding that a 20% drop in DOC export was recorded post blocking however this decrease was due to a reduction in water yield rather than a reduction in DOC concentration with the concentration record showing no significant reduction. The effect of external parameters become more pronounced as the DOC record is examined at larger scales. The catchment is an open system and water chemistry will be influence by mixing with water from other sources. Also it is likely that at some point the drains will cut across slope leading to the flow of any highly coloured water down slope, bypassing the blockages, and entering the surface waters downstream. Degradation of DOC will occur naturally downstream due to the effects of light and microbial activity. There is, consequently, a need to examine the wider effects of drain blocking at a catchment scale to ensure that what is observed for one drain transfers to the whole catchment. A series of blocked and unblocked catchments were studied in Upper Teesdale, Northern England. Drain water samples were taken at least daily at nine localities. These sites were located such that individual drains could be monitored in the context of a larger catchment. Water table depth, flow and weather parameters were recorded along with the collection of runoff and soil water samples. A detailed sampling programme was undertaken in which a series of drains were studied in the 12 months prior to and post blocking. This approach has allowed the effects of blocking on the carbon budget, water balance and flow pathways to be considered. Results indicate that the blocking of zero order drainage channels leads to a decrease in DOC export on an individual drain scale. However, this is due to a reduction in water yield rather than concentration. Concentrations are seen to rise by a small yet statistically significant amount in blocked zero order streams. The effect at a larger scale is more complex. Annual export values in the unblocked control catchment show a rise from zero to first order streams indicating that water is being added to the system at this scale from external spatially variable sources. This pattern is also recognised in the blocked catchment. The DOC concentration record in blocked drains at this larger scale however indicated a reduction relative to the unblocked catchment. This reduction points to a change in flow pathways post blocking as highly coloured water re-navigates its way downstream. References: Gibson H, Worrall F, Burt TP, Adamson JK (2009) DOC budgets of drained peat catchments: implications for DOC production in peat soils, Hydrological Processes 23(13) 1901-1911 Limpens J (2008) Peatlands and the carbon cycle: from local processes to global implications- a synthesis, Biogeosciences 5 1475-1491

  14. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... restricts wind motion across the open area between the pipe and the drain) that encloses the space between...., there is no pump) or is operated with no more than slight fluctuations in the liquid level, the owner or...

  15. Evaluating Use of Sub-Grade Drains with PFC for Stormwater Drainage : final report.

    DOT National Transportation Integrated Search

    2017-08-01

    The overarching objective of this project is to evaluate the effectiveness of incorporated subgrade drain (usually called underdrain) in the permeable friction course (PFC) pavement to facilitate drainage of stormwater within and on the pavemen...

  16. Healthy Blood Pressure "It's worth the effort!" | NIH MedlinePlus the Magazine

    MedlinePlus

    ... drain excess liquid. Add onion, green and red peppers – stir until tender Add kidney beans, diced tomatoes ... 16 oz) – rinse and drain 1 red bell pepper, diced 1 green bell pepper, diced 1 medium ...

  17. 18. ROSS POWERHOUSE: BUTTERFLY VALVE FROM BELOW AND SCROLL CASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. ROSS POWERHOUSE: BUTTERFLY VALVE FROM BELOW AND SCROLL CASE DRAIN. TAG INDICATES THE SCROLL CASE DRAIN WAS OPEN, 1989. - Skagit Power Development, Ross Powerhouse, On Skagit River, 10.7 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  18. Media filter drain : modified design evaluation and existing design longevity evaluation.

    DOT National Transportation Integrated Search

    2014-02-01

    The media filter drain (MFD), a stormwater water quality treatment best management practice, consists of media made up of : aggregate, perlite, gypsum and dolomite in a trench located along roadway shoulders with gravel and vegetative pre-filtering :...

  19. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  20. Design and simulation of a novel 1400 V-4000 V enhancement mode buried gate GaN HEMT for power applications

    NASA Astrophysics Data System (ADS)

    Faramehr, Soroush; Kalna, Karol; Igić, Petar

    2014-11-01

    A novel enhancement mode structure, a buried gate gallium nitride (GaN) high electron mobility transistor (HEMT) with a breakdown voltage (BV) of 1400 V-4000 V for a source-to-drain spacing (LSD) of 6 μm-32 μm, is investigated using simulations by Silvaco Atlas. The simulations are based on meticulous calibration of a conventional lateral 1 μm gate length GaN HEMT with a source-to-drain spacing of 6 μm against its experimental transfer characteristics and BV. The specific on-resistance RS for the new power transistor with the source-to-drain spacing of 6 μm showing BV = 1400 V and the source-to-drain spacing of 8 μm showing BV = 1800 V is found to be 2.3 mΩ · cm2 and 3.5 mΩ · cm2, respectively. Further improvement up to BV = 4000 V can be achieved by increasing the source-to-drain spacing to 32 μm with the specific on-resistance of RS = 35.5 mΩ · cm2. The leakage current in the proposed devices stays in the range of ˜5 × 10-9 mA mm-1.

  1. The safety of peri-articular local anaesthetic injection for patients undergoing total knee replacement with autologous blood transfusion: a randomised trial.

    PubMed

    Wallace, D F; Emmett, S R; Kang, K K; Chahal, G S; Hiskens, R; Balasubramanian, S; McGuinness, K; Parsons, H; Achten, J; Costa, M L

    2012-12-01

    Intra-operative, peri-articular injection of local anaesthesia is an increasingly popular way of controlling pain following total knee replacement. At the same time, the problems associated with allogenic blood transfusion have led to interest in alternative methods for managing blood loss after total knee replacement, including the use of auto-transfusion of fluid from the patient's surgical drain. It is safe to combine peri-articular infiltration with auto-transfusion from the drain. We performed a randomised clinical trial to compare the concentration of local anaesthetic in the blood and in the fluid collected in the knee drain in patients having either a peri-articular injection or a femoral nerve block. Clinically relevant concentrations of local anaesthetic were found in the fluid from the drains of patients having peri-articular injections (4.92 μg/ml (sd 3.151)). However, none of the patients having femoral nerve blockade had detectable levels. None of the patients in either group had clinically relevant concentrations of local anaesthetic in their blood after re-transfusion. The evidence from this study suggests that it is safe to use peri-articular injection in combination with auto-transfusion of blood from peri-articular drains during knee replacement surgery.

  2. Utility of drain fluid amylase measurement on the first postoperative day after distal pancreatectomy.

    PubMed

    Vass, David G; Hodson, James; Isaac, John; Marudanayagam, Ravi; Mirza, Darius F; Muiesan, Paolo; Roberts, Keith; Sutcliffe, Robert P

    2018-05-22

    Early exclusion of a postoperative pancreatic fistula (POPF) may facilitate earlier drain removal in selected patients after distal pancreatectomy. The purpose of this study was to evaluate the role of first postoperative day drain fluid amylase (DFA1) measurement to predict POPF. Patients in whom DFA1 was measured after distal pancreatectomy were identified from a prospectively maintained database over a five-year period. A cut-off value of DFA1 was derived using ROC analysis, which yielded sensitivity and negative predictive value of 100% for excluding POPF. DFA1 was available in 53 of 138 (38%) patients who underwent distal pancreatectomy. 19 of 53 patients (36%) developed a pancreatic fistula (Grade A - 15, Grade B - 3, Grade C - 1). Median DFA1 was significantly higher in those who developed a pancreatic fistula (5473; range 613-28,450) compared those without (802; range 57-2350). p < 0.0001. Using ROC analysis, a DFA1 less than 600 excluded pancreatic fistula with a sensitivity of 100% (AUROC of 0.91; SE = 0.04, p < 0.001). First postoperative day drain fluid amylase measurement may have a role in excluding pancreatic fistula after distal pancreatectomy. Such patients may be suitable for earlier drain removal. Copyright © 2017. Published by Elsevier Ltd.

  3. Carbon dioxide flux and net primary production of a boreal treed bog: responses to warming and water table manipulations

    NASA Astrophysics Data System (ADS)

    Munir, T. M.; Perkins, M.; Kaing, E.; Strack, M.

    2014-09-01

    Mid-latitude treed bogs are significant carbon (C) stocks and are highly sensitive to global climate change. In a dry continental treed bog, we compared three sites; control, recent (1-3 years; experimental) and older drained (10-13 years; drained) with water levels at 38, 74 and 120 cm below the surface, respectively. At each site we measured carbon dioxide (CO2) fluxes and tree root respiration (Rr) (across hummock-hollow microtopography of the forest floor) and net primary production (NPP) of trees during the growing seasons (May to October) of 2011-2013. The carbon (C) balance was calculated by adding net CO2 exchange of the forest floor (NEff-Rr) to the NPP of the trees. From cooler and wetter 2011 to driest and warmest 2013, The control site was a~C sink of 92, 70 and 76 g m-2, experimental site was a C source of 14, 57 and 135 g m-2, and drained site was a progressively smaller source of 26, 23 and 13 g m-2, respectively. Although all microforms at the experimental site had large net CO2 emissions, the longer-term drainage and deeper water level at the drained site resulted in the replacement of mosses with vascular plants (shrubs) at the hummocks and lichens at the hollows leading to the highest CO2 uptake at drained hummocks and significant losses at hollows. The tree NPP was highest at the drained site. We also quantified the impact of climatic warming at all water table treatments by equipping additional plots with open-top chambers (OTCs) that caused a passive warming on average of ∼1 °C and differential air warming of ∼6 °C (at mid-day full sun) across the study years. Warming significantly enhanced the shrub growth and CO2 sink function of the drained hummocks (exceeding the cumulative respiration losses at hollows induced by the lowered water level × warming). There was an interaction of water level with warming across hummocks that resulted in largest net CO2 uptake at warmed drained hummocks. Thus in 2013, the warming treatment enhanced the sink function of control by 13 g m-2, reduced the source function of experimental by 10 g m-2, and significantly enhanced the sink function of the drained site by 73 g m-2. Therefore, drying and warming in continental bogs is expected to initially accelerate C losses via respiration but persistent drought and warming is expected to restore the peatland's original C sink function as a result of transitional shift of vegetation between the microforms and increased NPP of trees over time.

  4. Water-quality conditions of the lower Boise River, Ada and Canyon Counties, Idaho, May 1994 through February 1997

    USGS Publications Warehouse

    Mullins, William H.

    1998-01-01

    Agricultural land and water use, wastewater treatment facility discharges, land development, road construction, urban runoff, confined-animal feeding operations, reservoir operations, and river channelization affect the water quality and biotic integrity of the lower Boise River between Lucky Peak Dam and the river's mouth at Parma, Idaho. During May 1994 through February 1997, 4 sites on the Boise River, 12 tributary/drain sites, and 3 wastewater treatment facilities were sampled at various intervals during the irrigation (high-flow) and post-irrigation (low-flow) seasons to determine sources, concentrations, and relative loads of nutrients and suspended sediment. Discharge entering the Boise River from the 12 tributary/drain sites and 3 wastewater treatment facilities was measured to determine the nutrient loads being contributed from each source. Total nitrogen, total phosphorus, and suspended sediment concentrations and loads tended to increase in a downstream direction along the Boise River. Among the 15 sources of discharge to the Boise River, 3 southside tributary/drains and the West Boise wastewater treatment facility contributed the largest loads of total nitrogen; the median daily load was more than 2,000 pounds per day. The West Boise wastewater treatment facility contributed the largest median daily load of total phosphorus (810 pounds per day); Dixie Drain contributed the largest median daily load of suspended sediment (26.4 tons per day). Nitrogen-to-phosphorus ratios at the four Boise River sites indicated that phosphorus could be limiting algal growth at the Diversion Dam site, whereas nitrogen could be limiting algal growth at the Glenwood and Middleton sites during some parts of the year. Algal growth in the Boise River near Parma did not appear to be nutrient limited. Because of the complexity of the plumbing system in the lower Boise River (numerous diversions and inflow points), accurate comparisons between discharge and nutrient loads entering the river at measured sites during high-flow sampling periods were difficult. During low-flow sampling periods, southside tributary/drains contributed most of the discharge and total nitrogen load, and wastewater treatment facilities contributed most of the total phosphorus load to the Boise River. During the 50-day period July 18 through September 5, 1996, the Idaho State standard for maximum daily average temperature for coldwater biota was exceeded by 34 percent at Middleton, 48 percent at Caldwell, and 80 percent near Parma. Violations of State standards for primary and secondary contact recreation were observed at all tributary/ drains and in the Boise River near Parma. Median instantaneous concentrations of fecal coliform bacteria exceeded State standards for primary contact recreation at five tributary/drains and exceeded standards for secondary contact recreation at one tributary/drain (Dixie Drain).

  5. Water quality in organic systems

    USDA-ARS?s Scientific Manuscript database

    Non-point source contamination is a major water quality concern in the upper Midwestern USA, where plant nutrients, especially NO3-N, are susceptible to leaching due to extensive subsurface draining of the highly productive, but poorly drained, soils found in this region. Environmental impacts assoc...

  6. 2. VIEW OF CENTRAL BEND OF LOWER DIAGONAL NO. 1 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW OF CENTRAL BEND OF LOWER DIAGONAL NO. 1 DRAIN, LOOKING 2932 EAST OF NORTH. - Truckee-Carson Irrigation District, Lower Diagonal No. 1 Drain, Bounded by West Gate Road & Weapons Delivery Road, Naval Air Station Fallon, Fallon, Churchill County, NV

  7. By-pass filters : taking your fleet the extra mile

    DOT National Transportation Integrated Search

    2000-01-01

    There has been an industry-wide push over the last few years to extend oil drain intervals on fleet equipment. This industry demand is an effort to reduce downtime, reduce waste oil generation, and cut maintenance costs. Extended oil drain intervals ...

  8. 3. VIEW NORTH, GENERAL VIEW SHOWING CANAL, DRAIN GATE GATEHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW NORTH, GENERAL VIEW SHOWING CANAL, DRAIN GATE GATEHOUSE ON RIGHT, HEADGATES AND GATEHOUSE IN DISTANCE - Norwich Water Power Company, West bank of Shetucket River beginning opposite Second Street & extending .8 mile northward, Greenville section, Norwich, New London County, CT

  9. Nitrate concentration-drainage flow (C-Q) relationship for a drained agricultural field in Eastern North Carolina Plain

    NASA Astrophysics Data System (ADS)

    Liu, W.; Youssef, M.; Birgand, F.; Chescheir, G. M.; Maxwell, B.; Tian, S.

    2017-12-01

    Agricultural drainage is a practice used to artificially enhance drainage characteristics of naturally poorly drained soils via subsurface drain tubing or open-ditch systems. Approximately 25% of the U.S. agricultural land requires improved drainage for economic crop production. However, drainage increases the transport of dissolved agricultural chemicals, particularly nitrates to downstream surface waters. Nutrient export from artificially drained agricultural landscapes has been identified as the leading source of elevated nutrient levels in major surface water bodies in the U.S. Controlled drainage has long been practiced to reduce nitrogen export from agricultural fields to downstream receiving waters. It has been hypothesized that controlled drainage reduces nitrogen losses by promoting denitrification, reducing drainage outflow from the field, and increasing plant uptake. The documented performance of the practice was widely variable as it depends on several site-specific factors. The goal of this research was to utilize high frequency measurements to investigate the effect of agricultural drainage and related management practices on nitrate fate and transport for an artificially drained agricultural field in eastern North Carolina. We deployed a field spectrophotometer to measure nitrate concentration every 45 minutes and measured drainage flow rate using a V-notch weir every 15 minutes. Furthermore, we measured groundwater level, precipitation, irrigation amount, temperature to characterize antecedent conditions for each event. Nitrate concentration-drainage flow (C-Q) relationships generated from the high frequency measurements illustrated anti-clockwise hysteresis loops and nitrate flushing mechanism in response to most precipitation and irrigation events. Statistical evaluation will be carried out for the C-Q relationships. The results of our analysis, combined with numerical modeling, will provide a better understanding of hydrological and biogeochemical processes controlling the fate and transport of nitrate in drained agricultural landscapes.

  10. The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu; Brinkmann, Debra H.; Ward, Shelly B.

    2013-03-15

    Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the secondmore » (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.« less

  11. Drain Failure in Intra-Abdominal Abscesses Associated with Appendicitis.

    PubMed

    Horn, Christopher B; Coleoglou Centeno, Adrian A; Guerra, Jarot J; Mazuski, John E; Bochicchio, Grant V; Turnbull, Isaiah R

    2018-04-01

    Previous studies have suggested that percutaneous drainage and interval appendectomy is an effective treatment for appendicitis with associated abscess. Few studies to date have analyzed risk factors for failed drain management. We hypothesized that older patients with more co-morbidities would be at higher risk for failing conservative treatment. The 2010-2014 editions of the National Inpatient Sample (NIS) were queried for patients with diagnoses of peri-appendiceal abscesses. Minors and elective admissions were excluded. We identified patients who underwent percutaneous drainage and defined drain failure as undergoing a surgical operation after drainage but during the same inpatient visit to assess for factors associated with failure of drainage alone as a treatment. After univariable analysis, binomial logistic regression was used to assess for independent risk factors. Frequencies were analyzed by χ 2 and continuous variables by Student's t-test. A total of 2,209 patients with appendiceal abscesses received drains; 561 patients (25.4%) failed conservative management and underwent operative intervention. On univariable analysis, patients who failed conservative management were younger, more likely to be Hispanic, have more inpatient diagnoses, and to have undergone drainage earlier in the hospital course. Multivariable regression demonstrated that the number of diagnoses, female sex, and Hispanic race were predictive of failure of drainage alone. Older age, West and Midwest census regions, and later drain placement were predictive of successful treatment with drainage alone. Failure was associated with more charges and longer hospital stay but not with a higher mortality rate. Approximately a quarter of patients will fail management of appendiceal abscess with percutaneous drain placement alone. Risk factors for failure are patient complexity, female sex, earlier drainage, and Hispanic race. Failure of drainage is associated with higher total charges and longer hospital stay; however, no change in the mortality rate was noted.

  12. What Is the Outcome of an Incision and Drainage Procedure in Endodontic Patients? A Prospective, Randomized, Single-blind Study.

    PubMed

    Beus, Hannah; Fowler, Sara; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike; Jatana, Courtney

    2018-02-01

    There are no prospective endodontic studies to determine the outcome of an incision and drainage (I&D) procedure for swelling in healthy, endodontic patients. The purpose of this prospective, randomized, single-blind study was to compare the postoperative course of I&D with drain placement versus a mock I&D procedure with mock drain placement after endodontic debridement in swollen emergency patients with symptomatic teeth and a pulpal diagnosis of necrosis. Eighty-one adult emergency patients presenting with clinical swelling received either penicillin or, if allergic, clindamycin and complete endodontic debridement, and then were randomly divided into 2 treatment groups: I&D with drain placement or a mock I&D procedure with mock drain placement. At the end of the appointment, all patients received a combination of ibuprofen/acetaminophen and, if needed, an opioid-containing escape medication. Patients recorded their pain and medication use for 4 days postoperatively. Success was defined as no or mild postoperative pain and no use of an opioid-containing escape medication. Success was evaluated using repeated measure mixed model logistic regression. Both groups had a decrease in postoperative pain and medication use over the 4 days. The mock I&D group had significantly higher success than the I&D group (odds ratio = 2.00; 95% confidence interval, 1.16-3.41). The success rate was 45% with the mock I&D and 33% with the I&D. After endodontic debridement, patients who received a mock I&D procedure with mock drain placement had more success than patients who received I&D with drain placement. Both groups clinically improved over 4 days. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. The addition of SPECT/CT lymphoscintigraphy to breast cancer radiation planning spares lymph nodes critical for arm drainage.

    PubMed

    Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A

    2013-03-15

    This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Antimicrobial prophylaxis to prevent surgical site infection in adolescent idiopathic scoliosis patients undergoing posterior spinal fusion: 2 doses versus antibiotics till drain removal.

    PubMed

    Kamath, Vijay H D; Cheung, Jason Pui Yin; Mak, Kin Cheung; Wong, Yat Wa; Cheung, Wai Yuen; Luk, Keith Dip Kei; Cheung, Kenneth Man Chee

    2016-10-01

    There is much variation in the choice, timing and duration of antimicrobial prophylaxis for preventing surgical site infections (SSI) but no guideline exists for scoliosis surgery. The aim of study was to compare the efficacy of two antimicrobial prophylaxis (AMP) protocols with cephazolin in preventing SSI in adolescent idiopathic scoliosis (AIS). A retrospective comparative analysis of two post-operative AMP protocols (two postoperative doses versus continued antibiotics till drain removal) was performed. Patient characteristics, pre-operative, intra- and post-operative risk factors for infection, drain use, generic drug name and number of doses administered were recorded from 226 patients with AIS who had undergone posterior spinal fusion. Details of superficial or deep SSI and wound healing aberrations, and serious adverse events were recorded. Analysis was performed to evaluate differences in the pre-, intra- and post-operative variables between the two groups. 155 patients received 2 postoperative doses of AMP and 71 patients had antibiotics till drain removal. The average follow-up was 43 months. The overall rate of SSI was 1.7 % for the spine wound and 1.3 % for the iliac crest wound. 1.9 % of patients with 2 doses of AMP and 1.4 % of patients with antibiotics till drain removal had SSI. No adverse reactions attributable to cephazolin were observed. This is the first study on the AMP protocol in scoliosis surgery for SSI prevention. Results suggest that two doses of AMP are as effective as continued antimicrobial use until drain removal. Cephazolin appears to be effective and safe for prophylaxis.

  15. Phylogenetic Profiles of In-House Microflora in Drains at a Food Production Facility: Comparison and Biocontrol Implications of Listeria-Positive and -Negative Bacterial Populations

    PubMed Central

    Solomon, Katie; Moore, John E.; Wall, Patrick G.; Fanning, Séamus

    2014-01-01

    Listeria species experience complex interactions with other microorganisms, which may promote growth and colonization of the organism in local environments or negatively affect them. This study investigated the microbial community at a food production facility, examining interactions between Listeria and the associated microbiome. Listeria species can be transferred between zones in the production environment by individuals or equipment, and drains may act as a reservoir for the organism, reflecting the microbial flora potentially in the production environment. Drains that were colonized by Listeria species and those determined to be free of Listeria were examined. In each case, 16S rRNA gene analysis was performed using the PhyloChip platform. Some general similarities in bacterial population structure were observed when Listeria-negative and -positive drain communities were compared, with some distinct differences also noted. These included increased populations of the genera Prevotella and Janthinobacterium associated with the absence of Listeria species, whereas Enterococcus and Rhodococcus were in higher abundance in drains colonized by Listeria species. Based on these results, a selection of bacterial species were grown in coculture biofilm with a Listeria monocytogenes strain identified as having colonized a drain at the facility. Mixed-species biofilm experiments showed that Janthinobacterium inhibited attachment and subsequent biofilm formation of L. monocytogenes; however, Enterococcus gallinarum significantly increased it. The results of this study suggest the microbial community in food processing facilities can impact the colonization of Listeria species and that influencing the microbiome in favor of antilisterial species may reduce the colonization of Listeria species and limit the likelihood of product/process contamination. PMID:24657862

  16. Evapotranspiration from drained wetlands: drivers, modeling, storage functions, and restoration implications

    NASA Astrophysics Data System (ADS)

    Shukla, S.; Wu, C. L.; Shrestha, N.

    2017-12-01

    Abstract Evapotranspiration (ET) is a major component of wetland and watershed water budgets. The effect of wetland drainage on ET is not well understood. We tested whether the current understanding of insignificant effect of drainage on ET in the temperate region wetlands applies to those in the sub-tropics. Eddy covariance (EC) based ET measurements were made for two years at two previously drained and geographically close wetlands in the Everglades region of Florida. One wetland was significantly drained with 97% of its storage capacity lost. The other was a more functional wetland with 42% of storage capacity lost. Annual average ET at the significantly drained wetland was 836 mm, 34% less than the function wetland (1271 mm) and the difference was statistically significant (p = 0.001). Such differences in wetland ET in the same climatic region have not been observed. The difference in ET was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two daily ET models, a regression (r2 = 0.80) and a Relevance Vector Machine (RVM) model (r2 = 0.84), were developed with the latter being more robust. These models, when used in conjunction with hydrologic models, improved ET predictions for drained wetlands. Predictions from an integrated model showed that more intensely drained wetlands at higher elevation should be targeted for restoration of downstream flows (flooding) because they have the ability to loose higher water volume through ET which increases available water storage capacity of wetlands. Daily ET models can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  17. Evapotranspiration from drained wetlands with different hydrologic regimes: Drivers, modeling, and storage functions

    NASA Astrophysics Data System (ADS)

    Wu, Chin-Lung; Shukla, Sanjay; Shrestha, Niroj K.

    2016-07-01

    We tested whether the current understanding of insignificant effect of drainage on evapotranspiration (ET) in the temperate region wetlands applies to those in the subtropics. Hydro-climatic drivers causing the changes in drained wetlands were identified and used to develop a generic model to predict wetland ET. Eddy covariance (EC)-based ET measurements were made for two years at two differently drained but close by wetlands, a heavily drained wetland (SW) (97% reduced surface storage) and a more functional wetland (DW) (42% reduced storage). Annual ET for more intensively drained SW was 836 mm, 34% less than DW (1271 mm) and the difference was significant (p = 0.001). This difference was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two generic daily ET models, a regression model (MSE = 0.44 mm2, R2 = 0.80) and a machine learning-based Relevance Vector Machine (RVM) model (MSE = 0.36 mm2, R2 = 0.84), were developed with the latter being more robust. The RVM model can predict changes in ET for different restoration scenarios; a 1.1 m rise in drainage level showed 7% increase ET (18 mm) at SW while the increase at DW was negligible. The additional ET, 28% of surface flow, can enhance water storage, flood protection, and climate mitigation services at SW compared to DW. More intensely drained wetlands at higher elevation should be targeted for restoration for enhanced storage through increased ET. The models developed can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  18. Lower pole anatomy and mid-renal-zone classification applied to flexible ureteroscopy: experimental study using human three-dimensional endocasts.

    PubMed

    Marroig, Bruno; Favorito, Luciano Alves; Fortes, Marco A; Sampaio, Francisco J B

    2015-12-01

    The aim of this study was to analyze the anatomy of the inferior pole collecting system and the mid-renal-zone classification in human endocasts applied to flexible ureteroscopy. 170 three-dimensional polyester resin endocasts of the kidney collecting system were obtained from 85 adult cadavers. We divided the endocasts into four groups: A1--kidney midzone (KM), drained by minor calices (mc) that are dependent on the superior or the inferior caliceal groups; A2--KM drained by crossed calices; B1--KM drained by a major caliceal group independent of both the superior and inferior groups; and B2--KM drained by mc entering directly into the renal pelvis. We studied the number of calices, the angle between the lower infundibulum and renal pelvis and the angle between the lower infundibulum and the inferior mc (LIICA). Means were statistically compared using ANOVA and the unpaired T test (p < 0.05). We found 57 (33.53 %) endocasts of group A1; 23 (13.53 %) of group A2; 59 (34.71 %) of group B1; and 31 (18.23 %) of group B2. The inferior pole was drained by four or more calices in 84 cases (49.41 %), distributed into groups as follows: A1 = 35 cases (41.67 %); A2 = 18 (21.43 %); B1 = 22 (26.19 %); and B2 = 9 (10.71 %). Perpendicular mc were observed in 15 cases (8.82 %). We did not observe statistical differences between the LIICA in the groups studied. Collector systems with kidney midzone drained by minor calices that are dependent on the superior or on the inferior caliceal groups presented at least two restrictive anatomical features. The mid-renal-zone classification was predictive of anatomical risk factors for lower pole ureteroscopy difficulties.

  19. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    PubMed

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  20. Innovative Technique for the Placement of the Drainage Tube for Microendoscopic Spinal Decompression.

    PubMed

    Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2017-02-01

    A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.

  1. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

    PubMed Central

    2018-01-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity (“water seal”) drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. PMID:29372629

  2. Perioperative lumbar drain utilization in transsphenoidal pituitary resection.

    PubMed

    Alharbi, Shatha; Harsh, Griffith; Ajlan, Abdulrazag

    2018-01-01

    To evaluate lumbar drain (LD) efficacy in transnasal resection of pituitary macroadenomas in preventing postoperative cerebrospinal fluid (CSF) leak, technique safety, and effect on length of hospital stay. We conducted a retrospective data review of pituitary tumor patients in our institution who underwent surgery between December 2006 and January 2013. All patients were operated on for complete surgical resection of pituitary macroadenoma tumors. Patients were divided into 2 groups: group 1 received a preoperative drain, while LD was not preoperatively inserted in group 2. In cases of tumors with suprasellar extension with anticipation of high-flow leak, LD was inserted after the patient was intubated and in a lateral position. Lumbar drain was used for 48 hours, and the drain was removed if no leak was observed postoperatively. In documented postoperative CSF leak patients with no preoperative drain, the leak was treated by LD trial prior to surgical reconstruction. Cases in which leak occurred 6 months postoperatively were excluded. Our study population consisted of 186 patients, 99 women (53%) and 87 men (47%), with a mean age of 50.3+/-16.1 years. Complications occurred in 7 patients (13.7%) in group 1 versus 21 (15.5%) in group 2 (p=0.72). Postoperative CSF leak was observed in 1 patient (1.9%) in group 1 and 7 (5%) in group 2 (Fisher exact test=0.3). Length of hospital stay was a mean of 4.7+/-1.9 days in group 1 and a mean of 2.7+/-2.4 days in group 2 (p<001). The most common reason to extend hospital stay was management of diabetes insipidus. Although LD insertion is generally considered safe with a low risk of complications, it increases the length of hospitalization. Minor complications include headaches and patient discomfort.

  3. 6. VIEW OF WEST GATE ROAD CULVERT OF LOWER DIAGONAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF WEST GATE ROAD CULVERT OF LOWER DIAGONAL NO. 1 DRAIN, LOOKING 2502 EAST OF NORTH. - Truckee-Carson Irrigation District, Lower Diagonal No. 1 Drain, Bounded by West Gate Road & Weapons Delivery Road, Naval Air Station Fallon, Fallon, Churchill County, NV

  4. 7. VIEW OF WEAPONS DELIVERY ROAD CULVERT OF LOWER DIAGONAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF WEAPONS DELIVERY ROAD CULVERT OF LOWER DIAGONAL NO. 1 DRAIN, LOOKING 522 EAST OF NORTH. - Truckee-Carson Irrigation District, Lower Diagonal No. 1 Drain, Bounded by West Gate Road & Weapons Delivery Road, Naval Air Station Fallon, Fallon, Churchill County, NV

  5. 5. VIEW OF WEST GATE ROAD CULVERT OF LOWER DIAGONAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF WEST GATE ROAD CULVERT OF LOWER DIAGONAL NO. 1 DRAIN, LOOKING 323' EAST OF NORTH. - Truckee-Carson Irrigation District, Lower Diagonal No. 1 Drain, Bounded by West Gate Road & Weapons Delivery Road, Naval Air Station Fallon, Fallon, Churchill County, NV

  6. A synthesis and comparative evaluation of drainage water management

    USDA-ARS?s Scientific Manuscript database

    Viable large-scale crop production in the United States requires artificial drainage in humid and poorly drained agricultural regions. Excess water removal is generally achieved by installing tile drains that export water to open ditches that eventually flow into streams. Drainage water management...

  7. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil system drains. 121.241 Section 121.241 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... position, must be provided to allow safe drainage of the entire oil system. ...

  8. 14 CFR 121.241 - Oil system drains.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oil system drains. 121.241 Section 121.241 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... position, must be provided to allow safe drainage of the entire oil system. ...

  9. Surficial geologic map of the Framingham quadrangle, Middlesex and Worcester Counties, Massachusetts

    USGS Publications Warehouse

    Nelson, Arthur E.

    1974-01-01

    With the exception of a small part of the southeast corner, which is drained by the Charles River, the quadrangle is drained by the Sudbury River, whose waters eventually flow into the Merrimack River in the northeast part of the state.

  10. Brain Migration Revisited

    ERIC Educational Resources Information Center

    Vinokur, Annie

    2006-01-01

    The "brain drain/brain gain" debate has been going on for the past 40 years, with irresolvable theoretical disputes and unenforceable policy recommendations that economists commonly ascribe to the lack of reliable empirical data. The recent report of the World Bank, "International migration, remittances and the brain drain", documents the…

  11. Structural alterations in tumor-draining lymph nodes before papillary thyroid carcinoma metastasis.

    PubMed

    Hinson, Andrew M; Massoll, Nicole A; Jolly, Lee Ann; Stack, Brendan C; Bodenner, Donald L; Franco, Aime T

    2017-08-01

    The purpose of this study was to define and characterize the thyroid tumor-draining lymph nodes in genetically engineered mice harboring thyroid-specific expression of oncogenic Braf V600E with and without Pten insufficiency. After intratumoral injection of methylene blue, the lymphatic drainage of the thyroid gland was visualized in real time. The thyroid gland/tumor was resected en bloc with the respiratory system for histological analysis. Although mice harboring Braf V600E mutations were smaller in body size compared with their wild-type (WT) littermates, the size of their thyroid glands and deep cervical lymph nodes were significantly larger. Additionally, the tumor-draining lymph nodes showed increased and enlarged lymphatic sinuses that were distributed throughout the cortex and medulla. Tumor-reactive lymphadenopathy and histiocytosis, but no frank metastases, were observed in all mice harboring Braf V600E mutations. The tumor-draining lymph nodes undergo significant structural alterations in immunocompetent mice, and this may represent a primer for papillary thyroid carcinoma (PTC) metastasis. © 2017 Wiley Periodicals, Inc.

  12. DNA Persistence in a Sink Drain Environment

    DOE PAGES

    Winder, Eric M.; Bonheyo, George T.

    2015-07-31

    Biofilms are organized structures composed mainly of cells and extracellular polymeric substances produced by the constituent microorganisms. Ubiquitous in nature, biofilms have an innate ability to capture and retain passing material and may therefore act as natural collectors of contaminants or signatures of upstream activities. To determine the persistence and detectability of DNA passing through a sink drain environment, Bacillus anthracis strain Ames35 was cultured (6.35 x 10 7 CFU/mL), sterilized, and disposed of by addition to a sink drain apparatus with an established biofilm. The sink drain apparatus was sampled before and for several days after the addition ofmore » the sterilized B. anthracis culture to detect the presence of B. anthracis DNA. Multiple PCR primer pairs were used to screen for chromosomal and plasmid DNA with primers targeting shorter sequences showing greater amplification efficiency and success. PCR amplification and detection of target sequences indicate persistence of chromosomal DNA and plasmid DNA in the biofilm for 5 or more and 14 or more days, respectively.« less

  13. Influence of Scattering on Ballistic Nanotransistor Design

    NASA Technical Reports Server (NTRS)

    Anantram, M. P.; Svizhenko, Alexei; Biegel, Bryan, A. (Technical Monitor)

    2002-01-01

    Importance of this work: (1) This is the first work to model electron-phonon scattering within a quantum mechanical approach to nanotransistors. The simulations use the non equilibrium Green's function method. (2) A simple equation which captures the importance of scattering as a function of the spatial location from source to drain is presented. This equation helps interpret the numerical simulations. (3) We show that the resistance per unit length in the source side is much larger than in the drain side. Thus making scattering in the source side of the device much more important than scattering in the drain side. Numerical estimates of ballisticity for 10nm channel length devices in the presence of of electron-phonon scattering are given. Based on these calculations, we propose that to achieve a larger on-current in nanotransistors, it is crucial to keep the highly doped source extension region extremely small, even if this is at the cost of making the highly doped drain extension region longer.

  14. Effects of annealing gas and drain doping concentration on electrical properties of Ge-source/Si-channel heterojunction tunneling FETs

    NASA Astrophysics Data System (ADS)

    Bae, Tae-Eon; Wakabayashi, Yuki; Nakane, Ryosho; Takenaka, Mitsuru; Takagi, Shinichi

    2018-04-01

    Improvement in the performance of Ge-source/Si-channel heterojunction tunneling FETs (TFETs) with high on-current/off-current (I on/I off) ratio and steep subthreshold swing (SS) is demonstrated. In this paper, we experimentally examine the effects of gas ambient [N2 and forming gas (4% H2/N2)] and a doping concentration in the drain regions on the electrical characteristics of Ge/Si heterojunction TFETs. The minimum SS (SSmin) of 70.9 mV/dec and the large I on/I off ratio of 1.4 × 107 are realized by postmetallization annealing in forming gas. Also, the steep SSmin and averaged SS (SSavr) values of 64.2 and 78.4 mV/dec, respectively, are obtained in low drain doping concentration. This improvement is attributable to the reduction in interface state density (D it) in the channel region and to the low leakage current in the drain region.

  15. DNA Persistence in a Sink Drain Environment

    PubMed Central

    Winder, Eric M.; Bonheyo, George T.

    2015-01-01

    Biofilms are organized structures composed mainly of cells and extracellular polymeric substances produced by the constituent microorganisms. Ubiquitous in nature, biofilms have an innate ability to capture and retain passing material and may therefore act as natural collectors of contaminants or signatures of upstream activities. To determine the persistence and detectability of DNA passing through a sink drain environment, Bacillus anthracis strain Ames35 was cultured (6.35 x 107 CFU/mL), sterilized, and disposed of by addition to a sink drain apparatus with an established biofilm. The sink drain apparatus was sampled before and for several days after the addition of the sterilized B. anthracis culture to detect the presence of B. anthracis DNA. Multiple PCR primer pairs were used to screen for chromosomal and plasmid DNA with primers targeting shorter sequences showing greater amplification efficiency and success. PCR amplification and detection of target sequences indicate persistence of chromosomal DNA and plasmid DNA in the biofilm for 5 or more and 14 or more days, respectively. PMID:26230525

  16. Reevaluating the need for routine drainage in reduction mammaplasty.

    PubMed

    Matarasso, A; Wallach, S G; Rankin, M

    1998-11-01

    The incidence of complications after reduction mammaplasty without drains was reviewed by analysis of 50 bilateral reduction mammaplasty procedures. Patients ranged in age from 14 to 65 years; the average combined volume removed was 953 g. Eighty-four percent of the patients underwent a Pitanguy technique, and the remaining patients underwent an inferior pedicle or amputative technique with free nipple grafts. Three patients had six complications; one of these patients had three of the complications. Complications included two cases of fat necrosis and one case of wound disruption. One patient had a hematoma with wound disruption and partial nipple loss. There were no cases of infection. The purpose of this study was to determine the rate of complications in reduction mammaplasty performed without drains. Incidentally, statistical analysis using the chi-squared test revealed that this series without drains compared favorably with previously published data for reduction mammaplasty using drains. It is concluded that routine closed suction drainage after reduction mammaplasty is unnecessary and should be reconsidered.

  17. DNA Persistence in a Sink Drain Environment.

    PubMed

    Winder, Eric M; Bonheyo, George T

    2015-01-01

    Biofilms are organized structures composed mainly of cells and extracellular polymeric substances produced by the constituent microorganisms. Ubiquitous in nature, biofilms have an innate ability to capture and retain passing material and may therefore act as natural collectors of contaminants or signatures of upstream activities. To determine the persistence and detectability of DNA passing through a sink drain environment, Bacillus anthracis strain Ames35 was cultured (6.35 x 107 CFU/mL), sterilized, and disposed of by addition to a sink drain apparatus with an established biofilm. The sink drain apparatus was sampled before and for several days after the addition of the sterilized B. anthracis culture to detect the presence of B. anthracis DNA. Multiple PCR primer pairs were used to screen for chromosomal and plasmid DNA with primers targeting shorter sequences showing greater amplification efficiency and success. PCR amplification and detection of target sequences indicate persistence of chromosomal DNA and plasmid DNA in the biofilm for 5 or more and 14 or more days, respectively.

  18. The effect of sea-water and fresh-water soaking on the quality of Eucheuma sp. syrup and pudding

    NASA Astrophysics Data System (ADS)

    Novianty, H.; Herandarudewi, S. M. C.

    2018-04-01

    Eucheuma alvarezii is one of marine commodity with great opportunities to be developed in Indonesia. This seaweed can be used as an additional material in cosmetic and pharmaceutical products or for syrup and pudding. Post-harvest technique conducted by the seaweed farmers will affects the quality of dried and processed products. The purpose of this study was to observe the effect of post harvest technique on the quality of dried seaweed and hedonic test (favorable test) of processed product (syrup and pudding). This study was conducted using descriptive method. The study compared dried, syrup, and puddings from two differents post-harvest technique, between salt and fresh-water draining products. The results showed that fresh-water draining technique obtained better quality results organoleptic test. The results showed that panelist prefered the fresh-water drained products of syrup and pudding. The hedonic scores were much higher for the fresh-water drained products in all three catagories of color, taste, and smell.

  19. Modeling and risk assessment of a 30-Year-old subsurface radioactive-liquid drain field

    NASA Astrophysics Data System (ADS)

    Dawson, Lon A.; Pohl, Phillip I.

    1997-11-01

    The contamination from a 30-year-old radioactive liquid drain field was assessed for movement in the subsurface and potential risks to humans. This assessment included determining field concentrations of cesium 137 (137Cs) and other inorganic contaminants and modeling of the flow and transport of the liquid waste that was sent to the drain field. The field investigation detected no contamination deeper than 15 feet (4.6 m) from the bottom of the drain field. Prediction of the water content of the vadose zone showed no saturated conditions for times greater than 10 years after the known infiltration. Sensitivity analysis of the modeling parameters showed the equilibrium sorption coefficient to be the most important factor in predicting the contaminant plumes. Calibration of modeling results with field data gave a 137Cs sorption coefficient that is within the range of values found in the literature. The risk assessment for the site showed that the contamination poses no significant risk to human health.

  20. Direct imprinting of indium-tin-oxide precursor gel and simultaneous formation of channel and source/drain in thin-film transistor

    NASA Astrophysics Data System (ADS)

    Haga, Ken-ichi; Kamiya, Yuusuke; Tokumitsu, Eisuke

    2018-02-01

    We report on a new fabrication process for thin-film transistors (TFTs) with a new structure and a new operation principle. In this process, both the channel and electrode (source/drain) are formed simultaneously, using the same oxide material, using a single nano-rheology printing (n-RP) process, without any conventional lithography process. N-RP is a direct thermal imprint technique and deforms oxide precursor gel. To reduce the source/drain resistance, the material common to the channel and electrode is conductive indium-tin-oxide (ITO). The gate insulator is made of a ferroelectric material, whose high charge density can deplete the channel of the thin ITO film, which realizes the proposed operation principle. First, we have examined the n-RP conditions required for the channel and source/drain patterning, and found that the patterning properties are strongly affected by the cooling rate before separating the mold. Second, we have fabricated the TFTs as proposed and confirmed their TFT operation.

  1. Nitrogen and phosphorus loading from drained wetlands adjacent to Upper Klamath and Agency lakes, Oregon

    USGS Publications Warehouse

    Snyder, Daniel T.; Morace, Jennifer L.

    1997-01-01

    The results of this study could be useful in helping to prioritize which drained wetlands may provide the greatest benefits with regard to reducing nutrient loads to the lake if restoration or land-use modifications are instituted. Recent acquisition and planned restoration of drained wetland areas at the Wood River and Williamson River North properties may produce significant reduction in the quantity of nutrients released by the decomposition of peat soils of these areas. If the water table rises to predrainage levels, the peats soils may become inundated most of the year, resulting in the continued long-term storage of nutrients within the peat soils by reducing aerobic decomposition. The maximum benefit, in terms of decreasing potential nutrient loss due to peat decomposition, could be the reduction of total nitrogen and total phosphorus loss to about one-half that of the 1994–95 annual loss estimated for all the drained wetlands sampled for this study.

  2. Passively operated spool valve for drain-down freeze protection of thermosyphon water heaters. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1982-04-30

    The work done to extend the existing drain-down valve technology to provide passive drain-down freeze protection for thermosyphon-based solar water heaters is described. The basic design of the existing valve model is that of a spool valve, employing a cylindrical spool which moves axially in a mating cartridge to open and close o-rings at the two operating extremes (drain and operate) to perform the valving function. Three passive actuators to drive the basic valving mechanism were designed, fabricated, and tested. Two piping configurations used to integrate the spool valve with the thermosyphon system are described, as are the passive actuators.more » The three actuator designs are: photovoltaic driven, refrigerant-based bellows, and heat motor cable-drive designs. Costs are compared for the alternative actuator designs, and operating characteristics were examined for the thermosyphon system, including field tests. The market for the valve for thermosyphon systems is then assessed. (LEW)« less

  3. Regenerative switching CMOS system

    DOEpatents

    Welch, James D.

    1998-01-01

    Complementary Metal Oxide Semiconductor (CMOS) Schottky barrier Field Effect Transistor systems, which are a seriesed combination of N and P-Channel MOSFETS, in which Source Schottky barrier junctions of the N and P-Channel Schottky barrier MOSFETS are electically interconnected, (rather than the Drains as in conventional diffused junction CMOS), which Schottky barrier MOSFET system demonstrates Regenerative Inverting Switching Characteristics in use are disclosed. Both the N and P-Channel Schottky barrier MOSFET devices are unique in that they provide operational Drain Current vs. Drain to Source voltage as a function of Gate voltage only where the polarities of the Drain voltage and Gate voltage are opposite, referenced to the Source as a common terminal, and where the polarity of the voltage applied to the Gate is appropriate to cause Channel inversion. Experimentally derived results which demonstrate and verify the operation of N and P-Channel Schottky barrier MOSFETS actually fabricated on P and N-type Silicon respectively, by a common procedure using vacuum deposited Chromium as a Schottky barrier forming metal, are also provided.

  4. Regenerative switching CMOS system

    DOEpatents

    Welch, J.D.

    1998-06-02

    Complementary Metal Oxide Semiconductor (CMOS) Schottky barrier Field Effect Transistor systems, which are a series combination of N and P-Channel MOSFETS, in which Source Schottky barrier junctions of the N and P-Channel Schottky barrier MOSFETS are electrically interconnected, (rather than the Drains as in conventional diffused junction CMOS), which Schottky barrier MOSFET system demonstrates Regenerative Inverting Switching Characteristics in use are disclosed. Both the N and P-Channel Schottky barrier MOSFET devices are unique in that they provide operational Drain Current vs. Drain to Source voltage as a function of Gate voltage only where the polarities of the Drain voltage and Gate voltage are opposite, referenced to the Source as a common terminal, and where the polarity of the voltage applied to the Gate is appropriate to cause Channel inversion. Experimentally derived results which demonstrate and verify the operation of N and P-Channel Schottky barrier MOSFETS actually fabricated on P and N-type Silicon respectively, by a common procedure using vacuum deposited Chromium as a Schottky barrier forming metal, are also provided. 14 figs.

  5. Climate mitigation scenarios of drained peat soils

    NASA Astrophysics Data System (ADS)

    Kasimir Klemedtsson, Åsa; Coria, Jessica; He, Hongxing; Liu, Xiangping; Nordén, Anna

    2014-05-01

    The national inventory reports (NIR) submitted to the UNFCCC show Sweden - which as many other countries has wetlands where parts have been drained for agriculture and forestry purposes, - to annually emit 12 million tonnes carbon dioxide equivalents, which is more GHG'es than industrial energy use release in Sweden. Similar conditions can be found in other northern countries, having cool and wet conditions, naturally promoting peat accumulation, and where land use management over the last centuries have promoted draining activities. These drained peatland, though covering only 2% of the land area, have emissions corresponding to 20% of the total reported NIR emissions. This substantial emission contribution, however, is hidden within the Land Use Land Use Change and Forestry sector (LULUCF) where the forest Carbon uptake is even larger, which causes the peat soil emissions become invisible. The only drained soil emission accounted in the Swedish Kyoto reporting is the N2O emission from agricultural drained organic soils of the size 0.5 million tonnes CO2e yr-1. This lack of visibility has made incentives for land use change and management neither implemented nor suggested, however with large potential. Rewetting has the potential to decrease soil mineralization, why CO2 and N2O emissions are mitigated. However if the soil becomes very wet CH4 emission will increase together with hampered plant growth. By ecological modeling, using the CoupModel the climate change mitigation potential have been estimated for four different land use scenarios; 1, Drained peat soil with Spruce (business as usual scenario), 2, raised ground water level to 20 cm depth and Willow plantation, 3, raised ground water level to 10 cm depth and Reed Canary Grass, and 4, rewetting to an average water level in the soil surface with recolonizing wetland plants and mosses. We calculate the volume of biomass production per year, peat decomposition, N2O emission together with nitrate and DOC/POC leakage. Based on the modelling results a cost benefit analysis is performed (economics), guiding to the design of environmental policies needed for land use change to come true.

  6. Soil surface CO2 flux in a boreal black spruce fire chronosequence

    NASA Astrophysics Data System (ADS)

    Wang, Chuankuan; Bond-Lamberty, Ben; Gower, Stith T.

    2003-02-01

    Understanding the effects of wildfire on the carbon (C) cycle of boreal forests is essential to quantifying the role of boreal forests in the global carbon cycle. Soil surface CO2 flux (Rs), the second largest C flux in boreal forests, is directly and indirectly affected by fire and is hypothesized to change during forest succession following fire. The overall objective of this study was to measure and model Rs for a black spruce (Picea mariana [Mill.] BSP) postfire chronosequence in northern Manitoba, Canada. The experiment design was a nested factorial that included two soil drainage classes (well and poorly drained) × seven postfire aged stands. Specific objectives were (1) to quantify the relationship between Rs and soil temperature for different aged boreal black spruce forests in well-drained and poorly drained soil conditions, (2) to examine Rs dynamics along postfire successional stands, and (3) to estimate annual soil surface CO2 flux for these ecosystems. Soil surface CO2 flux was significantly affected by soil drainage class (p = 0.014) and stand age (p = 0.006). Soil surface CO2 flux was positively correlated to soil temperature (R2 = 0.78, p < 0.001), but different models were required for each drainage class × aged stand combination. Soil surface CO2 flux was significantly greater at the well-drained than the poorly drained stands (p = 0.007) during growing season. Annual soil surface CO2 flux for the 1998, 1995, 1989, 1981, 1964, 1930, and 1870 burned stands averaged 226, 412, 357, 413, 350, 274, and 244 g C m-2 yr-1 in the well-drained stands and 146, 380, 300, 303, 256, 233, and 264 g C m-2 yr-1 in the poorly drained stands. Soil surface CO2 flux during the winter (from 1 November to 30 April) comprised from 5 to 19% of the total annual Rs. We speculate that the smaller soil surface CO2 flux in the recently burned than the older stands is mainly caused by decreased root respiration.

  7. Soil surface CO2 flux in a boreal black spruce fire chronosequence

    NASA Astrophysics Data System (ADS)

    Wang, Chuankuan; Bond-Lamberty, Ben; Gower, Stith T.

    2002-02-01

    Understanding the effects of wildfire on the carbon (C) cycle of boreal forests is essential to quantifying the role of boreal forests in the global carbon cycle. Soil surface CO2 flux (Rs), the second largest C flux in boreal forests, is directly and indirectly affected by fire and is hypothesized to change during forest succession following fire. The overall objective of this study was to measure and model Rs for a black spruce (Picea mariana [Mill.] BSP) postfire chronosequence in northern Manitoba, Canada. The experiment design was a nested factorial that included two soil drainage classes (well and poorly drained) × seven postfire aged stands. Specific objectives were (1) to quantify the relationship between Rs and soil temperature for different aged boreal black spruce forests in well-drained and poorly drained soil conditions, (2) to examine Rs dynamics along postfire successional stands, and (3) to estimate annual soil surface CO2 flux for these ecosystems. Soil surface CO2 flux was significantly affected by soil drainage class (p = 0.014) and stand age (p = 0.006). Soil surface CO2 flux was positively correlated to soil temperature (R2 = 0.78, p < 0.001), but different models were required for each drainage class × aged stand combination. Soil surface CO2 flux was significantly greater at the well-drained than the poorly drained stands (p = 0.007) during growing season. Annual soil surface CO2 flux for the 1998, 1995, 1989, 1981, 1964, 1930, and 1870 burned stands averaged 226, 412, 357, 413, 350, 274, and 244 g C m-2 yr-1 in the well-drained stands and 146, 380, 300, 303, 256, 233, and 264 g C m-2 yr-1 in the poorly drained stands. Soil surface CO2 flux during the winter (from 1 November to 30 April) comprised from 5 to 19% of the total annual Rs. We speculate that the smaller soil surface CO2 flux in the recently burned than the older stands is mainly caused by decreased root respiration.

  8. Outcome in primary cemented total knee arthroplasty with or without drain: A prospective comparative study

    PubMed Central

    Kęska, Rafał; Paradowski, T Przemysław; Witoński, Dariusz

    2014-01-01

    Background: Suction drain insertion is a common practice in orthopedic surgery, especially after joint arthroplasty to prevent the formation of a hematoma. Theoretically the use of a drain should diminish the volume of hematoma; however the literature has conflicting data. Some authors state that drainage evacuates fluid from a limited area only and can be a cause of infection due to retrograde migration of bacteria. It can also impair the early postoperative rehabilitation. The aim of this study was to evaluate the clinical outcome (especially postoperative pain) and intake of analgesics in patients who had undergone primary cemented total knee arthroplasty (TKA) with or without a postoperative drain. Materials and Methods: A prospective comparative study of 108 consecutive patients (121 knees) was conducted. They were divided into two groups: A study group, with no drainage and a control group with drain inserted at the end of surgery. A total of 121 patients were recruited into two groups. A study group consisted of 59 knees, in which we did not use drainage after TKA and a control group with 62 knees, in which drain was inserted post surgery. Both groups were comparable in terms of preoperative characteristics. The indication for TKA was osteoarthritis (n = 105) and rheumatoid arthritis (n = 16). Results: In patients without drainage we observed lower need for opioids, higher blood loss on the 1st postoperative day and a lower need for change of dressings. There were no statistically significant differences in terms of total blood loss, hidden blood loss, transfusion rate, range of motion, length of hospital stay or incidence of complications between the two groups. In 1 year observation there were no differences in clinical outcome between the two groups. Conclusions: The present study conclude that there is no rationale for the use of drain after primary TKA. There are benefits in terms of lower opioid intake, lower blood loss on the first postoperative day and lower need for dressing reinforcement during hospitalization. PMID:25143646

  9. Chemical fractionation of metals in wetland sediments: Indiana Dunes National Lakeshore.

    PubMed

    Dollar, N L; Souch, C J; Filippelli, G M; Mastalerz, M

    2001-09-15

    Tessier-type (1979) sequential extractions for heavy metals (Cd, Cr, Cu, Fe, Mn, Pb, and Zn) were conducted on sediments from two wetland sites, one inundated and the other drained, within the Indiana Dunes National Lakeshore (IDNL), NW Indiana, with the objective of (i) evaluating extraction techniques on organic-rich sediments, (ii) determining the geochemistry and mobility of potentially biotoxic trace metals in a contaminated environment, and (iii) considering the implications of different restoration strategies on the potential for heavy metal remobilization. Long and repeated extractions were needed to effectively degrade the organic-rich sediments (up to 75% of the sediment by mass). Analysis of sulfur fractionation revealed that it was predominantly sequestered along with the organically bound fraction (renamed oxidizable). Metal recovery was good with the sum of the extractant steps typically within 20% of the total metal concentration determined after total microwave digestion. Results showed metal fractionation to be both metal- and site-specific, The oxidizable fraction is dominant for Cu, Cr, and Fe (>65% of the nonresidual fraction for almost all samples) and overall is most important also for Cd and Pb. The iron/manganese oxide fraction is important for Pb, Mn, and Zn, particularly at the drained site. The carbonate bound fraction is relatively insignificant at both sites, except for Cd and Mn, although it is more important at the drained site. The exchangeable fraction is significant in the uppermost sediments at the drained site, particularly for Cd (3-24%), Pb (3-14%), and Zn (36-45%); whereas, for the inundated site, it ranged only from 0 to 1% Zn, with no detectable Cd or Pb. Chromium, Cu, and Fe exist in forms not likely to be remobilized, whereas Cd, Mn, Pb, and Zn are potentially mobile if drained wetland sites are reflooded (and pH and redox potential altered). Simple mass balance calculations illustrate the potential for the removal of approximately 84,375 kg of exchangeable Zn if currently drained sites across the IDNL are reflooded, with concentrations in water draining into Lake Michigan as high as 5 ppm.

  10. Agricultural peatland restoration: effects of land-use change on greenhouse gas (CO2 and CH4) fluxes in the Sacramento-San Joaquin Delta.

    PubMed

    Knox, Sara Helen; Sturtevant, Cove; Matthes, Jaclyn Hatala; Koteen, Laurie; Verfaillie, Joseph; Baldocchi, Dennis

    2015-02-01

    Agricultural drainage of organic soils has resulted in vast soil subsidence and contributed to increased atmospheric carbon dioxide (CO2) concentrations. The Sacramento-San Joaquin Delta in California was drained over a century ago for agriculture and human settlement and has since experienced subsidence rates that are among the highest in the world. It is recognized that drained agriculture in the Delta is unsustainable in the long-term, and to help reverse subsidence and capture carbon (C) there is an interest in restoring drained agricultural land-use types to flooded conditions. However, flooding may increase methane (CH4) emissions. We conducted a full year of simultaneous eddy covariance measurements at two conventional drained agricultural peatlands (a pasture and a corn field) and three flooded land-use types (a rice paddy and two restored wetlands) to assess the impact of drained to flooded land-use change on CO2 and CH4 fluxes in the Delta. We found that the drained sites were net C and greenhouse gas (GHG) sources, releasing up to 341 g C m(-2) yr(-1) as CO2 and 11.4 g C m(-2) yr(-1) as CH4. Conversely, the restored wetlands were net sinks of atmospheric CO2, sequestering up to 397 g C m(-2) yr(-1). However, they were large sources of CH4, with emissions ranging from 39 to 53 g C m(-2) yr(-1). In terms of the full GHG budget, the restored wetlands could be either GHG sources or sinks. Although the rice paddy was a small atmospheric CO2 sink, when considering harvest and CH4 emissions, it acted as both a C and GHG source. Annual photosynthesis was similar between sites, but flooding at the restored sites inhibited ecosystem respiration, making them net CO2 sinks. This study suggests that converting drained agricultural peat soils to flooded land-use types can help reduce or reverse soil subsidence and reduce GHG emissions. © 2014 John Wiley & Sons Ltd.

  11. [Effects of tranexamic acid combined with temporary drain clamping on postoperative blood loss in total knee arthroplasty].

    PubMed

    Dong, Yi-Long; Qian, Yue-Nan; Zhong, Xi-Qiang; Shen, Guang-Jie; Cai, Chun-Yuan

    2017-04-25

    To evaluate the efficacy and safety of one dose tranexamic acid combined with temporary drain lamping in primary unilateral total knee arthroplasty. Total 160 patients undergoing unilateral primary total knee arthroplasty between January 2012 and December 2013 were randomly divided into four groups(40 cases in each group):group A (the drain was clamped for 2 hours after the operation and the patients received 20 ml physiological saline), group B(the drain was clamped for 2 hours after the operation and the patients received 10 ml tranexamic acid and 10 ml physiological saline), group C (the drain was clamped for 4 hours after the operation and the patients received 20 ml physiological saline) and group D(the drain was clamped for 4 hours after the operation and the patients received 10 ml tranexamic acid and 10 ml physiological saline). The postoperative hemoglobin level, maximum hemoglobin loss, wound drainage, blood loss, the volume of blood transfusion, the number of patients inquiring blood transfusion, venous thrombo embolism rate, and ecchymosis rate were recorded and compared among the four groups. There was no incision infection, severe hypoxia, and symptomatic pulmonary embolism in these groups. There were significant differences in hemoglobin content one day after operation in each group( F =12.26, P =0.000), in the hemoglobin content 7 days after operation in each group( F =20.74, P =0.000), in postoperative drainage in each group( F =38.71, P =0.000);in the amount of invisible red blood cell loss in each group( F =83.41, P =0.000), and in total red blood cell loss in each group( F =102.68, P =0.000). Color Doppler ultrasound examination found that the total incidence of VTE was 3%(5/160) and there were no significant differences in each group( P =0.892). There were no significant differences in postoperative subcutaneous ecchymosis area>1% incidence( P =0.143). Topical tranexami acid treatment combined with temporary clamping of drain for 4 hours could reduce postoperative blood loss, blood transfusion, and ecchymosis rate without increasing the risk of thromboembolic event after total knee arthroplasty.

  12. Poly(3,3‴-didodecylquarterthiophene) field effect transistors with single-walled carbon nanotube based source and drain electrodes

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan Yuan; Shi, Yumeng; Chen, Fuming; Mhaisalkar, S. G.; Li, Lain-Jong; Ong, Beng S.; Wu, Yiliang

    2007-11-01

    A solution processable method for employing single-walled carbon nanotubes (SWCNTs) as bottom contact source/drain electrodes for a significant reduction of contact resistance in poly(3,3‴-didodecylquarterthiophene) based organic field effect transistors (OFETs) is proposed. A two order of magnitude reduction in contact resistance and up to a threefold improvement in field effect mobilities were observed in SWCNT contacted OFETs as opposed to similar devices with gold source/drain electrodes. Based on Kelvin probe measurements, this improvement was attributed to a reduction in the Schottky barrier for hole injection into organic semiconductor.

  13. Measuring bi-directional current through a field-effect transistor by virtue of drain-to-source voltage measurement

    DOEpatents

    Turner, Steven Richard

    2006-12-26

    A method and apparatus for measuring current, and particularly bi-directional current, in a field-effect transistor (FET) using drain-to-source voltage measurements. The drain-to-source voltage of the FET is measured and amplified. This signal is then compensated for variations in the temperature of the FET, which affects the impedance of the FET when it is switched on. The output is a signal representative of the direction of the flow of current through the field-effect transistor and the level of the current through the field-effect transistor. Preferably, the measurement only occurs when the FET is switched on.

  14. Models of second-order effects in metal-oxide-semiconductor field-effect transistors for computer applications

    NASA Technical Reports Server (NTRS)

    Benumof, Reuben; Zoutendyk, John; Coss, James

    1988-01-01

    Second-order effects in metal-oxide-semiconductor field-effect transistors (MOSFETs) are important for devices with dimensions of 2 microns or less. The short and narrow channel effects and drain-induced barrier lowering primarily affect threshold voltage, but formulas for drain current must also take these effects into account. In addition, the drain current is sensitive to channel length modulation due to pinch-off or velocity saturation and is diminished by electron mobility degradation due to normal and lateral electric fields in the channel. A model of a MOSFET including these considerations and emphasizing charge conservation is discussed.

  15. Small signal measurement of Sc 2O 3 AlGaN/GaN moshemts

    NASA Astrophysics Data System (ADS)

    Luo, B.; Mehandru, R.; Kang, B. S.; Kim, J.; Ren, F.; Gila, B. P.; Onstine, A. H.; Abernathy, C. R.; Pearton, S. J.; Gotthold, D.; Birkhahn, R.; Peres, B.; Fitch, R.; Gillespie, J. K.; Jenkins, T.; Sewell, J.; Via, D.; Crespo, A.

    2004-02-01

    The rf performance of 1 × 200 μm 2 AlGaN/GaN MOS-HEMTs with Sc 2O 3 used as both the gate dielectric and as a surface passivation layer is reported. A maximum fT of ˜11 GHz and fMAX of 19 GHz were obtained. The equivalent device parameters were extracted by fitting this data to obtain the transconductance, drain resistance, drain-source resistance, transfer time and gate-drain and gate-source capacitance as a function of gate voltage. The transfer time is in the order 0.5-1 ps and decreases with increasing gate voltage.

  16. Changing Workplace.

    ERIC Educational Resources Information Center

    1998

    This document contains four papers from a symposium on the changing workplace and its relationship to human resource development (HRD). In "Globalization, Immigration and Quality of Life Dynamics for Reverse Brain Drains" (Ben-Chieh Liu, Maw Lin Lee, Hau-Lien), the factors responsible for the brain drain from Taiwan to the United States…

  17. Cultural Resources Investigations of the West Bank Hurricane Protection Project, Jefferson Parish, Louisiana

    DTIC Science & Technology

    1989-09-01

    most common understory plants include thistle (Carduus sp.), violet (Viola sp.), bur- marigold (Bidens laevis), and ferns. Drained cypress-tupelo swamp... marigold (Bidens laevis), violet (Viola sp.), thistle (Carduus sp.), and Southern shield fern (Thelypteris kunthil). Drained marsh makes up the

  18. MOSES Support Platform

    DTIC Science & Technology

    2008-02-01

    drain with collector • Final pressure switch with gauge and automatic shut- off • (2) Hour meter • Oil filled finel pressure gauge 0~400bar/5800psi...Automatic condensate drain system Final pressure switch with gauge and automatic shut-off (2) Hour meter, (2) On/Off Switch Filling Connection Four

  19. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other junction boxes (e.g., manholes, sumps, and lift stations) conveying regulated-material. For the purpose of... segregated from all other individual drain systems. Junction box means a sump, manhole, or access point to a...

  20. Phosphorus modeling in tile drained agricultural systems using APEX

    USDA-ARS?s Scientific Manuscript database

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

Top