Sample records for draize eye test

  1. Alternatives to In Vivo Draize Rabbit Eye and Skin Irritation Tests with a Focus on 3D Reconstructed Human Cornea-Like Epithelium and Epidermis Models

    PubMed Central

    Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min

    2017-01-01

    Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350

  2. Prediction of ocular irritancy of 26 chemicals and 26 cosmetic products with isolated rabbit eye (IRE) test.

    PubMed

    Guo, Xiang; Yang, Xing Fen; Yang, Ying; Hans, Raabe; Cai, Jing Heng; Xue, Jin Yu; Tan, Xiao Hua; Xie, Xiao Ping; Xiong, Xi Kun; Huang, Jun Ming

    2012-06-01

    This study aims to establish and evaluate the methodology of isolated rabbit eye (IRE) test. IRE test was performed according to modifications of the in vitro toxicology (INVITTOX) Protocol No.85: Rabbit enucleated eye test by European Centre for the Validation of Alternative Methods (ECVAM), and then 26 chemicals and 26 cosmetic products were tested in both in vitro IRE and in vivo Draize tests. A statistical analysis was conducted to determine the relevance of the IRE test to the data generated in the Draize test. IRE test was established successfully in our laboratory. It was shown that ranking correlation and class concordance were fairly well between the IRE test and the Draize test for 26 reference chemicals (Fisher's Exact Test χ(2)=51.314, P<0.001; McNemar P=0.261; Gamma=0.960, P<0.001; Kappa=0.843, P<0.001) and 26 cosmetic products (Fisher's Exact Test χ(2)=15.522, P<0.001; McNemar P=0.311; Gamma=0.967, P<0.001; Kappa=0.611, P<0.001). IRE test was established successfully for in vitro testing of eye irritation as an alternative to Draize test. Copyright © 2012 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.

  3. Retrospective analysis of the Draize test for serious eye damage/eye irritation: importance of understanding the in vivo endpoints under UN GHS/EU CLP for the development and evaluation of in vitro test methods.

    PubMed

    Adriaens, Els; Barroso, João; Eskes, Chantra; Hoffmann, Sebastian; McNamee, Pauline; Alépée, Nathalie; Bessou-Touya, Sandrine; De Smedt, Ann; De Wever, Bart; Pfannenbecker, Uwe; Tailhardat, Magalie; Zuang, Valérie

    2014-03-01

    For more than two decades, scientists have been trying to replace the regulatory in vivo Draize eye test by in vitro methods, but so far only partial replacement has been achieved. In order to better understand the reasons for this, historical in vivo rabbit data were analysed in detail and resampled with the purpose of (1) revealing which of the in vivo endpoints are most important in driving United Nations Globally Harmonized System/European Union Regulation on Classification, Labelling and Packaging (UN GHS/EU CLP) classification for serious eye damage/eye irritation and (2) evaluating the method's within-test variability for proposing acceptable and justifiable target values of sensitivity and specificity for alternative methods and their combinations in testing strategies. Among the Cat 1 chemicals evaluated, 36-65 % (depending on the database) were classified based only on persistence of effects, with the remaining being classified mostly based on severe corneal effects. Iritis was found to rarely drive the classification (<4 % of both Cat 1 and Cat 2 chemicals). The two most important endpoints driving Cat 2 classification are conjunctiva redness (75-81 %) and corneal opacity (54-75 %). The resampling analyses demonstrated an overall probability of at least 11 % that chemicals classified as Cat 1 by the Draize eye test could be equally identified as Cat 2 and of about 12 % for Cat 2 chemicals to be equally identified as No Cat. On the other hand, the over-classification error for No Cat and Cat 2 was negligible (<1 %), which strongly suggests a high over-predictive power of the Draize eye test. Moreover, our analyses of the classification drivers suggest a critical revision of the UN GHS/EU CLP decision criteria for the classification of chemicals based on Draize eye test data, in particular Cat 1 based only on persistence of conjunctiva effects or corneal opacity scores of 4. In order to successfully replace the regulatory in vivo Draize eye test, it will be important to recognise these uncertainties and to have in vitro tools to address the most important in vivo endpoints identified in this paper.

  4. [Cytotoxicity of chemicals used in household products: estimation of eye irritating potency of 25 chemicals tested during 1991-1996].

    PubMed

    Ikarashi, Y; Tsuchiya, T; Nakamura, A

    1997-01-01

    Cytotoxicity potential of chemicals was evaluated by determining the concentrations inducing 50% reduction of neutral red (NR) uptake into Chinese hamster fibroblast V79 cells compared with control culture (IC50). The results of cytotoxicity test for surfactants with the data produced by the in vivo Draize eye and skin irritation test were compared. There was a good correlation between cytotoxicity and eye irritation score obtained from the Draize test. In contrast, no correlation was observed between Draize skin irritation score and cytotoxic potential of chemicals. Therefore, the NR cytotoxicity test was regarded as a possible in vitro model for predicting eye irritation. Based on the IC50 values in the NR cytotoxicity test, the eye irritation classification (weak, moderate and strong) for each chemical used in household products has been established. We evaluated the cytotoxicity of 25 chemicals used for antimicrobial, rubber accelerator, rubber antioxidant, ultraviolet absorber etc. in household products, and estimated the eye irritating potency of these test chemicals according to the criterion.

  5. Analysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008–2014 REACH Data

    PubMed Central

    Luechtefeld, Thomas; Maertens, Alexandra; Russo, Daniel P.; Rovida, Costanza; Zhu, Hao; Hartung, Thomas

    2017-01-01

    Summary Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retesting of substances. This allowed assessment of the test’s reproducibility based on all substances tested more than once. There was a 10% chance of a non-irritant evaluation after a prior severe-irritant result according to UN GHS classification criteria. The most reproducible outcomes were the results negative (94% reproducible) and severe eye irritant (73% reproducible). To evaluate whether other GHS categorizations predict eye irritation, we built a dataset of 5,629 substances (1,931 “irritant” and 3,698 “non-irritant”). The two best decision trees with up to three other GHS classifications resulted in balanced accuracies of 68% and 73%, i.e., in the rank order of the Draize rabbit eye test itself, but both use inhalation toxicity data (“May cause respiratory irritation”), which is not typically available. Next, a dataset of 929 substances with at least one Draize study was mapped to PubChem to compute chemical similarity using 2D conformational fingerprints and Tanimoto similarity. Using a minimum similarity of 0.7 and simple classification by the closest chemical neighbor resulted in balanced accuracy from 73% over 737 substances to 100% at a threshold of 0.975 over 41 substances. This represents a strong support of read-across and (Q)SAR approaches in this area. PMID:26863293

  6. The CTFA Evaluation of Alternatives Program: an evaluation of in vitro alternatives to the Draize primary eye irritation test. (Phase III) surfactant-based formulations.

    PubMed

    Gettings, S D; Lordo, R A; Hintze, K L; Bagley, D M; Casterton, P L; Chudkowski, M; Curren, R D; Demetrulias, J L; Dipasquale, L C; Earl, L K; Feder, P I; Galli, C L; Glaza, S M; Gordon, V C; Janus, J; Kurtz, P J; Marenus, K D; Moral, J; Pape, W J; Renskers, K J; Rheins, L A; Roddy, M T; Rozen, M G; Tedeschi, J P; Zyracki, J

    1996-01-01

    The CTFA Evaluation of Alternatives Program is an evaluation of the relationship between data from the Draize primary eye irritation test and comparable data from a selection of promising in vitro eye irritation tests. In Phase III, data from the Draize test and 41 in vitro endpoints on 25 representative surfactant-based personal care formulations were compared. As in Phase I and Phase II, regression modelling of the relationship between maximum average Draize score (MAS) and in vitro endpoint was the primary approach adopted for evaluating in vitro assay performance. The degree of confidence in prediction of MAS for a given in vitro endpoint is quantified in terms of the relative widths of prediction intervals constructed about the fitted regression curve. Prediction intervals reflect not only the error attributed to the model but also the material-specific components of variation in both the Draize and the in vitro assays. Among the in vitro assays selected for regression modeling in Phase III, the relationship between MAS and in vitro score was relatively well defined. The prediction bounds on MAS were most narrow for materials at the lower or upper end of the effective irritation range (MAS = 0-45), where variability in MAS was smallest. This, the confidence with which the MAS of surfactant-based formulations is predicted is greatest when MAS approaches zero or when MAS approaches 45 (no comment is made on prediction of MAS > 45 since extrapolation beyond the range of observed data is not possible). No single in vitro endpoint was found to exhibit relative superiority with regard to prediction of MAS. Variability associated with Draize test outcome (e.g. in MAS values) must be considered in any future comparisons of in vivo and in vitro test results if the purpose is to predict in vivo response using in vitro data.

  7. Screening for eye irritancy using cultured HeLa cells.

    PubMed

    Selling, J; Ekwall, B

    1985-01-01

    To investigate whether toxicity tests on HeLa cells were predictive of eye irritancy, 18 compounds of known eye irritancy and in vitro cytotoxicity were tested on HeLa cells in the MIT-24 system. The results correlated well with eye irritancy as determined by the Draize test in rabbits for 16 of the test substances, but failed to detect the high eye irritancy of 1-heptanol and allyl alcohol, both of which were cytotoxic in other cellular systems.

  8. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. CON4EI: Selection of the reference chemicals for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R

    2017-10-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Reprint of "CON4EI: Selection of the reference chemicals for hazard identification and labelling of eye irritating chemicals".

    PubMed

    Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2018. Published by Elsevier Ltd.

  11. Cosmetics Europe compilation of historical serious eye damage/eye irritation in vivo data analysed by drivers of classification to support the selection of chemicals for development and evaluation of alternative methods/strategies: the Draize eye test Reference Database (DRD).

    PubMed

    Barroso, João; Pfannenbecker, Uwe; Adriaens, Els; Alépée, Nathalie; Cluzel, Magalie; De Smedt, Ann; Hibatallah, Jalila; Klaric, Martina; Mewes, Karsten R; Millet, Marion; Templier, Marie; McNamee, Pauline

    2017-02-01

    A thorough understanding of which of the effects assessed in the in vivo Draize eye test are responsible for driving UN GHS/EU CLP classification is critical for an adequate selection of chemicals to be used in the development and/or evaluation of alternative methods/strategies and for properly assessing their predictive capacity and limitations. For this reason, Cosmetics Europe has compiled a database of Draize data (Draize eye test Reference Database, DRD) from external lists that were created to support past validation activities. This database contains 681 independent in vivo studies on 634 individual chemicals representing a wide range of chemical classes. A description of all the ocular effects observed in vivo, i.e. degree of severity and persistence of corneal opacity (CO), iritis, and/or conjunctiva effects, was added for each individual study in the database, and the studies were categorised according to their UN GHS/EU CLP classification and the main effect driving the classification. An evaluation of the various in vivo drivers of classification compiled in the database was performed to establish which of these are most important from a regulatory point of view. These analyses established that the most important drivers for Cat 1 Classification are (1) CO mean ≥ 3 (days 1-3) (severity) and (2) CO persistence on day 21 in the absence of severity, and those for Cat 2 classification are (3) CO mean ≥ 1 and (4) conjunctival redness mean ≥ 2. Moreover, it is shown that all classifiable effects (including persistence and CO = 4) should be present in ≥60 % of the animals to drive a classification. As a consequence, our analyses suggest the need for a critical revision of the UN GHS/EU CLP decision criteria for the Cat 1 classification of chemicals. Finally, a number of key criteria are identified that should be taken into consideration when selecting reference chemicals for the development, evaluation and/or validation of alternative methods and/or strategies for serious eye damage/eye irritation testing. Most important, the DRD is an invaluable tool for any future activity involving the selection of reference chemicals.

  12. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

    PubMed Central

    Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-01-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556

  13. Estimation of the chemical-induced eye injury using a Weight-of-Evidence (WoE) battery of 21 artificial neural network (ANN) c-QSAR models (QSAR-21): part II: corrosion potential.

    PubMed

    Verma, Rajeshwar P; Matthews, Edwin J

    2015-03-01

    This is part II of an in silico investigation of chemical-induced eye injury that was conducted at FDA's CFSAN. Serious eye damage caused by chemical (eye corrosion) is assessed using the rabbit Draize test, and this endpoint is an essential part of hazard identification and labeling of industrial and consumer products to ensure occupational and consumer safety. There is an urgent need to develop an alternative to the Draize test because EU's 7th amendment to the Cosmetic Directive (EC, 2003; 76/768/EEC) and recast Regulation now bans animal testing on all cosmetic product ingredients and EU's REACH Program limits animal testing for chemicals in commerce. Although in silico methods have been reported for eye irritation (reversible damage), QSARs specific for eye corrosion (irreversible damage) have not been published. This report describes the development of 21 ANN c-QSAR models (QSAR-21) for assessing eye corrosion potential of chemicals using a large and diverse CFSAN data set of 504 chemicals, ADMET Predictor's three sensitivity analyses and ANNE classification functionalities with 20% test set selection from seven different methods. QSAR-21 models were internally and externally validated and exhibited high predictive performance: average statistics for the training, verification, and external test sets of these models were 96/96/94% sensitivity and 91/91/90% specificity. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. CON4EI: Evaluation of QSAR models for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Geerts, L; Adriaens, E; Alépée, N; Guest, R; Willoughby, J A; Kandarova, H; Drzewiecka, A; Fochtman, P; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: eye irritation.

    PubMed

    McNamee, Pauline; Hibatallah, Jalila; Costabel-Farkas, Margit; Goebel, Carsten; Araki, Daisuke; Dufour, Eric; Hewitt, Nicola J; Jones, Penny; Kirst, Annette; Le Varlet, Béatrice; Macfarlane, Martin; Marrec-Fairley, Monique; Rowland, Joanna; Schellauf, Florian; Scheel, Julia

    2009-07-01

    The need for alternative approaches to replace the in vivo rabbit Draize eye test for evaluation of eye irritation of cosmetic ingredients has been recognised by the cosmetics industry for many years. Extensive research has lead to the development of several assays, some of which have undergone formal validation. Even though, to date, no single in vitro assay has been validated as a full replacement for the rabbit Draize eye test, organotypic assays are accepted for specific and limited regulatory purposes. Although not formally validated, several other in vitro models have been used for over a decade by the cosmetics industry as valuable tools in a weight of evidence approach for the safety assessment of ingredients and finished products. In light of the deadlines established in the EU Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision-tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. Furthermore, recommendations are given on how remaining data gaps and research needs can be addressed.

  16. CON4EI: Development of testing strategies for hazard identification and labelling for serious eye damage and eye irritation of chemicals.

    PubMed

    Adriaens, E; Verstraelen, S; Alépée, N; Kandarova, H; Drzewiecka, A; Gruszka, K; Guest, R; Willoughby, J A; Van Rompay, A R

    2018-06-01

    Assessment of acute eye irritation potential is part of the international regulatory requirements for safety testing of chemicals. In the last decades, many efforts have been made in the search for alternative methods to replace the regulatory in vivo Draize rabbit eye test (OECD TG 405). Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. The main objective of the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for serious eye damage and eye irritation assessment that can lead to complete replacement of OECD TG 405. A set of 80 reference chemicals (e.g. balanced by important driver of classification and physical state), was tested with seven test methods. Based on the results of this project, three different strategies were suggested. We have provided a standalone (EpiOcular ET-50), a two-tiered and three-tiered strategy, that can be used to distinguish between Cat 1 and Cat 2 chemicals and chemicals that do not require classification (No Cat). The two-tiered and three-tiered strategies use an RhCE test method (EpiOcular EIT or SkinEthic™ EIT) at the bottom (identification No Cat) in combination with the BCOP LLBO (two-tiered strategy) or BCOP OP-KIT and SMI (three-tiered strategy) at the top (identification Cat 1). For our proposed strategies, 71.1% - 82.9% Cat 1, 64.2% - 68.5% Cat 2 and ≥80% No Cat chemicals were correctly identified. Also, similar results were obtained for the Top-Down and Bottom-Up approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.

    PubMed

    Spöler, Felix; Kray, Oya; Kray, Stefan; Panfil, Claudia; Schrage, Norbert F

    2015-07-01

    Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy. 2015 FRAME.

  18. Estimation of the chemical-induced eye injury using a weight-of-evidence (WoE) battery of 21 artificial neural network (ANN) c-QSAR models (QSAR-21): part I: irritation potential.

    PubMed

    Verma, Rajeshwar P; Matthews, Edwin J

    2015-03-01

    Evaluation of potential chemical-induced eye injury through irritation and corrosion is required to ensure occupational and consumer safety for industrial, household and cosmetic ingredient chemicals. The historical method for evaluating eye irritant and corrosion potential of chemicals is the rabbit Draize test. However, the Draize test is controversial and its use is diminishing - the EU 7th Amendment to the Cosmetic Directive (76/768/EEC) and recast Regulation now bans marketing of new cosmetics having animal testing of their ingredients and requires non-animal alternative tests for safety assessments. Thus, in silico and/or in vitro tests are advocated. QSAR models for eye irritation have been reported for several small (congeneric) data sets; however, large global models have not been described. This report describes FDA/CFSAN's development of 21 ANN c-QSAR models (QSAR-21) to predict eye irritation using the ADMET Predictor program and a diverse training data set of 2928 chemicals. The 21 models had external (20% test set) and internal validation and average training/verification/test set statistics were: 88/88/85(%) sensitivity and 82/82/82(%) specificity, respectively. The new method utilized multiple artificial neural network (ANN) molecular descriptor selection functionalities to maximize the applicability domain of the battery. The eye irritation models will be used to provide information to fill the critical data gaps for the safety assessment of cosmetic ingredient chemicals. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    PubMed

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  20. Evaluation of a three-dimensional human dermal model as a predictor of shampoo ocular irritation.

    PubMed

    Decker, D; Harper, R

    1994-04-01

    A three-dimensional human tissue model (Skin(2) ZK1100) was used to evaluate 43 adult and baby shampoos. The ZK1100 model consists of metabolically active proliferating human fibroblasts isolated from the dermis of neonatal foreskins and seeded onto a nylon mesh. The fibroblasts multiply and produce matrix proteins to form a living tissue. MTT reduction (mitochondrial function) was used as the cytotoxicity endpoint. The primary components of the adult shampoos are alkyl sulfate surfactants, while the baby shampoos contain ethoxylated alkyl sulfates and amphoteric surfactants. All shampoos were diluted to five concentrations (100, 300, 700, 1000 and 3000 mug/ml) in aqueous cell culture media and the tissue exposed for 24 hr. An EC(50) value for each test was generated from a dose-response curve. All samples were tested in two or more separate experiments, and the EC(50) values were averaged and plotted versus their respective 24-hr unwashed Draize eye irritation values (r(2) = 0.81). The adult shampoos had Draize values in the moderate irritation category and EC(50) values ranging from 220 to 1051 mug/ml, while the baby shampoos had Draize values in the minimal irritation category and EC(50) values ranging from 820 to 2285 mug/ml. These results indicate that the three-dimensional human tissue model can be useful in predicting the Draize ocular irritation category for shampoos.

  1. Computerized In Vitro Test for Chemical Toxicity Based on Tetrahymena Swimming Patterns

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Matsos, Helen C.; Cronise, Raymond J.; Looger, Loren L.; Relwani, Rachna A.; Johnson, Jacqueline U.

    1994-01-01

    An apparatus and a method for rapidly determining chemical toxicity have been evaluated as an alternative to the rabbit eye initancy test (Draize). The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The method, called the motility assay (MA), is tested for 30 s to determine the chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy.

  2. A new cell-based method for assessing the eye irritation potential of chemicals: an alternative to the Draize test.

    PubMed

    Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong

    2012-07-20

    Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    PubMed

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  4. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests

    PubMed Central

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2014-01-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%). PMID:27134543

  5. Adverse reactions to cosmetics and methods of testing.

    PubMed

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  6. Lacking applicability of in vitro eye irritation methods to identify seriously eye irritating agrochemical formulations: Results of bovine cornea opacity and permeability assay, isolated chicken eye test and the EpiOcular™ ET-50 method to classify according to UN GHS.

    PubMed

    Kolle, Susanne N; Van Cott, Andrew; van Ravenzwaay, Bennard; Landsiedel, Robert

    2017-04-01

    In vitro methods have gained regulatory acceptance for the prediction of serious eye damage (UN GHS Cat 1). However, the majority of in vitro methods do not state whether they are applicable to agrochemical formulations. This manuscript presents a study of up to 27 agrochemical formulations tested in three in vitro assays (three versions of the bovine corneal opacity and permeability test (BCOP, OECD TG 437) assay, the isolated chicken eye test (ICE, OECD TG 438) and the EpiOcular™ ET-50 assay). The results were compared with already-available in vivo data. In the BCOP only one of the four, one of five in the ICE and six of eleven tested formulations in the EpiOcular™ ET-50 Neat Protocol resulted in the correct UN GHS Cat 1 prediction. Overpredictions occurred in all assays. These data indicate a lack of applicability of the three in vitro methods to reliably predict UN GHS Cat 1 of agrochemical formulations. In order to ensure animal-free identification of seriously eye damaging agrochemical formulations testing protocols and/or prediction models need to be modified or classification rules should be tailored to in vitro testing rather than using in vivo Draize data as a standard. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. CON4EI: Development of serious eye damage and eye irritation testing strategies with respect to the requirements of the UN GHS/EU CLP hazard categories.

    PubMed

    Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. CON4EI: Slug Mucosal Irritation (SMI) test method for hazard identification and labelling of serious eye damaging and eye irritating chemicals.

    PubMed

    Adriaens, E; Guest, R; Willoughby, J A; Fochtman, P; Kandarova, H; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. The objective of CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment that can lead to complete replacement of the in vivo Draize rabbit eye test (OECD TG 405). A set of 80 reference chemicals was tested with seven test methods, one method was the Slug Mucosal Irritation (SMI) test method. The method measures the amount of mucus produced (MP) during a single 1-hour contact with a 1% and 10% dilution of the chemical. Based on the total MP, a classification (Cat 1, Cat 2, or No Cat) is predicted. The SMI test method correctly identified 65.8% of the Cat 1 chemicals with a specificity of 90.5% (low over-prediction rate for in vivo Cat 2 and No Cat chemicals). Mispredictions were predominantly unidirectional towards lower classifications with 26.7% of the liquids and 40% of the solids being underpredicted. In general, the performance was better for liquids than for solids with respectively 76.5% vs 57.1% (Cat 1), 61.5% vs 50% (Cat 2), and 87.5% vs 85.7% (No Cat) being identified correctly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™.

    PubMed

    Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min

    2015-09-01

    Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.

  10. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    PubMed

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  11. Short Time Exposure (STE) test in conjunction with Bovine Corneal Opacity and Permeability (BCOP) assay including histopathology to evaluate correspondence with the Globally Harmonized System (GHS) eye irritation classification of textile dyes.

    PubMed

    Oliveira, Gisele Augusto Rodrigues; Ducas, Rafael do Nascimento; Teixeira, Gabriel Campos; Batista, Aline Carvalho; Oliveira, Danielle Palma; Valadares, Marize Campos

    2015-09-01

    Eye irritation evaluation is mandatory for predicting health risks in consumers exposed to textile dyes. The two dyes, Reactive Orange 16 (RO16) and Reactive Green 19 (RG19) are classified as Category 2A (irritating to eyes) based on the UN Globally Harmonized System for classification (UN GHS), according to the Draize test. On the other hand, animal welfare considerations and the enforcement of a new regulation in the EU are drawing much attention in reducing or replacing animal experiments with alternative methods. This study evaluated the eye irritation of the two dyes RO16 and RG19 by combining the Short Time Exposure (STE) and the Bovine Corneal Opacity and Permeability (BCOP) assays and then comparing them with in vivo data from the GHS classification. The STE test (first level screening) categorized both dyes as GHS Category 1 (severe irritant). In the BCOP, dye RG19 was also classified as GHS Category 1 while dye RO16 was classified as GHS no prediction can be made. Both dyes caused damage to the corneal tissue as confirmed by histopathological analysis. Our findings demonstrated that the STE test did not contribute to arriving at a better conclusion about the eye irritation potential of the dyes when used in conjunction with the BCOP test. Adding the histopathology to the BCOP test could be an appropriate tool for a more meaningful prediction of the eye irritation potential of dyes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Comparison of cytotoxicity in vitro and irritation in vivo for aqueous and oily solutions of surfactants.

    PubMed

    Czajkowska-Kośnik, Anna; Wolska, Eliza; Chorążewicz, Juliusz; Sznitowska, Małgorzata

    2015-01-01

    The in vivo model on rabbit eyes and the in vitro cytotoxicity on fibroblasts were used to compare irritation effect of aqueous and oily (Miglyol 812) solutions of surfactants. Tween 20, Tween 80 and Cremophor EL were tested in different concentrations (0.1, 1 or 5%) and the in vitro test demonstrated that surfactants in oil are less cytotoxic than in aqueous solutions. In the in vivo study, the aqueous solutions of surfactants were characterized as non-irritant while small changes in conjunctiva were observed after application the oily solutions of surfactants and the preparations were classified as slightly irritant, however this effect was similar when Miglyol was applied alone. In conclusion, it is reported that the MTT assay does not correlate well with the Draize scores.

  13. Two-stage bottom-up tiered approach combining several alternatives for identification of eye irritation potential of chemicals including insoluble or volatile substances.

    PubMed

    Hayashi, Kazuhiko; Mori, Taeko; Abo, Takayuki; Ooshima, Kenichi; Hayashi, Takumi; Komano, Tomoko; Takahashi, Yutaka; Sakaguchi, Hitoshi; Takatsu, Akihiko; Nishiyama, Naohiro

    2012-10-01

    For the assessment of eye irritation, one alternative test may not completely replace the rabbit Draize test. In the present study, we examined the predictive potential of a tiered approach analyzing the results from several alternatives (i.e., the Short Time Exposure (STE) test, the EpiOcular assay, the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) assay and the Bovine Corneal Opacity and Permeability (BCOP) assay) for assessing Globally Harmonized System (GHS) eye irritation categories. Fifty-six chemicals including alcohols, surfactants, and esters were selected with a balanced GHS category and a wide range of chemical classes. From a standpoint of both assessable sample numbers and predictive accuracy, the more favorable tiered approach was considered to be the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay (accuracy 69.6%, under prediction rate 8.9%). Moreover, a more favorable predictive capacity (accuracy 71.4%, under prediction rate 3.6%) was obtained when high volatile alcohols/esters with vapor pressures >6 kilopascal (kPa) at 25°C were evaluated with EpiOcular assay instead of the STE test. From these results, the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay might be a promising method for the classification of GHS eye irritation category (Not classified (NC), Category 2 (Cat. 2), and Category 1 (Cat. 1)) for a wide range of test chemicals regardless of solubility. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. The EpiOcular™ Eye Irritation Test is the Method of Choice for the In Vitro Eye Irritation Testing of Agrochemical Formulations: Correlation Analysis of EpiOcular Eye Irritation Test and BCOP Test Data According to the UN GHS, US EPA and Brazil ANVISA Classification Schemes.

    PubMed

    Kolle, Susanne N; Rey Moreno, Maria Cecilia; Mayer, Winfried; van Cott, Andrew; van Ravenzwaay, Bennard; Landsiedel, Robert

    2015-07-01

    The Bovine Corneal Opacity and Permeability (BCOP) test is commonly used for the identification of severe ocular irritants (GHS Category 1), but it is not recommended for the identification of ocular irritants (GHS Category 2). The incorporation of human reconstructed tissue model-based tests into a tiered test strategy to identify ocular non-irritants and replace the Draize rabbit eye irritation test has been suggested (OECD TG 405). The value of the EpiOcular™ Eye Irritation Test (EIT) for the prediction of ocular non-irritants (GHS No Category) has been demonstrated, and an OECD Test Guideline (TG) was drafted in 2014. The purpose of this study was to evaluate whether the BCOP test, in conjunction with corneal histopathology (as suggested for the evaluation of the depth of the injury( and/or the EpiOcular-EIT, could be used to predict the eye irritation potential of agrochemical formulations according to the UN GHS, US EPA and Brazil ANVISA classification schemes. We have assessed opacity, permeability and histopathology in the BCOP assay, and relative tissue viability in the EpiOcular-EIT, for 97 agrochemical formulations with available in vivo eye irritation data. By using the OECD TG 437 protocol for liquids, the BCOP test did not result in sufficient correct predictions of severe ocular irritants for any of the three classification schemes. The lack of sensitivity could be improved somewhat by the inclusion of corneal histopathology, but the relative viability in the EpiOcular-EIT clearly outperformed the BCOP test for all three classification schemes. The predictive capacity of the EpiOcular-EIT for ocular non-irritants (UN GHS No Category) for the 97 agrochemical formulations tested (91% sensitivity, 72% specificity and 82% accuracy for UN GHS classification) was comparable to that obtained in the formal validation exercise underlying the OECD draft TG. We therefore conclude that the EpiOcular-EIT is currently the best in vitro method for the prediction of the eye irritation potential of liquid agrochemical formulations. 2015 FRAME.

  15. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion

    PubMed Central

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728

  16. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion.

    PubMed

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.

  17. Ocular toxicity of authentic lunar dust

    PubMed Central

    2012-01-01

    Background Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind’s limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Methods Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). Results In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Conclusions Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance. PMID:22817808

  18. Ocular toxicity of authentic lunar dust.

    PubMed

    Meyers, Valerie E; Garcìa, Hector D; Monds, Kathryn; Cooper, Bonnie L; James, John T

    2012-07-20

    Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind's limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance.

  19. Clinical effect of four different ointment bases on healthy cat eyes.

    PubMed

    Eördögh, Réka; Schwendenwein, Ilse; Tichy, Alexander; Loncaric, Igor; Nell, Barbara

    2016-07-01

    To describe the effects of long-term treatment with four different eye ointment bases (OBs) in cats. Ten healthy cats. The study was performed in two periods. Four different OBs were tested. Hundred grams of OB contained the following: OB-A: 35.17 g liquid paraffin (lp), 64.83 g white petrolatum (wp); OB-B: 10.03 g lp, 84.95 g wp 5.02 g lanolin; OB-C: 18.34 g lp, 51.40 g wp, 25.00 mg KH2 PO4 , 57.00 mg K2 HPO4 , 18.90 g eucerinum anhydricum, 11.28 g water for injections; and OB-D: 70 g unguentum lanalcoli, 20 g lp, 10 g aqua conservans. One eye was treated, and the other served as a negative control. Cats received the OBs TID for 28 days. The two study periods were separated by a 4-month washout phase. Samples for conjunctival impression cytology, swabs for bacteriologic and mycologic examination, and cytobrush samples for FHV-1 and Chlamydophila felis PCR detection were obtained. Both eyes were examined daily. Severity of ocular symptoms was scored using a modified Draize eye irritation test. A total of five eyes were treated with OB-A, five with OB-B, four with OB-C, and five with OB-D. Treated eyes had significantly higher clinical scores. Eyes receiving OB-A had the highest overall clinical score. The results of bacteriologic and mycologic examination concur with the previously published data. All samples tested were negative for FHV-1 and Chlamydophila felis. There was no significant difference between treated and control eyes upon cytological examination. The application of OBs resulted in clinical symptoms in treated eyes. The long-term use of ointments is not well tolerated in cats and may lead to ocular irritation. © 2015 American College of Veterinary Ophthalmologists.

  20. Determining the pharmacological activity of Physalis peruviana fruit juice on rabbit eyes and fibroblast primary cultures.

    PubMed

    Pardo, Juan Manuel; Fontanilla, Marta Raquel; Ospina, Luis Fernando; Espinosa, Lady

    2008-07-01

    The pharmacologic activity of compounds isolated from Physalis peruviana has been demonstrated. The use of this fruit juice for treating pterygium has been reported in Colombian traditional medicine. However, studies demonstrating the fruit juice's pharmacologic activity when used in this disease have not been published to date. In the present study the anti-inflammatory and cytostatic activities of P. peruviana fruit juice in a rabbit eye inflammatory model were investigated. A novel rabbit eye inflammation model was developed for studying the juice's anti-inflammatory activity (based on an adaptation of the Draize test). Cytostatic activity was evaluated by measuring and comparing growth rates of cultured fibroblasts exposed and not exposed to various fruit juice concentrations. P. peruviana fruit juice exhibited a mild anti-inflammatory activity compared with methylprednisolone, a known anti-inflammatory drug. An interesting dose-dependent cytostatic effect on cultured fibroblasts was also established. The data found suggest that the P. peruviana fruit juice anti-pterygium effect described in traditional medicine may be related to its inhibiting fibroblast growth. The present study contributes to the pharmacologic knowledge regarding a remedy commonly used in Colombian traditional medicine.

  1. Semiautomated Motility Assay For Determining Toxicity

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Cronise, Raymond

    1996-01-01

    Improved method of assessing toxicities of various substances based on observation of effects of those substances on motilities of manageably small number of cells of protozoan species Tetrahema pyriformis. Provides repeatable, standardized tests with minimal handling by technicians and with minimal exposure of technicians to chemicals. Rapid and economical alternative to Draize test.

  2. Design and elaboration of freeze-dried PLGA nanoparticles for the transcorneal permeation of carprofen: Ocular anti-inflammatory applications.

    PubMed

    Parra, Alexander; Mallandrich, Mireia; Clares, Beatriz; Egea, María A; Espina, Marta; García, María L; Calpena, Ana C

    2015-12-01

    This work aimed the design and development of poly(lactic-co-glycolic) acid (PLGA) nanoparticles (NPs) for the ocular delivery of Carprofen (CP) by a central rotatable composite design 2(3)+ star. NPs showed adequate size for ocular administration (189.50 ± 1.67 nm), low polydispersity (0.01 ± 0.01), negative charge surface (-22.80 ± 0.66 mV) and optimal entrapment efficiency (74.70 ± 0.95%). Physicochemical analysis confirmed that CP was dispersed inside the NPs. The drug release followed a first order kinetic model providing greater sustained CP release after lyophilization. Ex vivo permeation analysis through isolated rabbit cornea revealed that a sufficient amount of CP was retained in the tissue avoiding excessive permeation and thus, potential systemic levels. Ex vivo ocular tolerance results showed no signs of ocular irritancy, which was also confirmed by in vivo Draize test. In vivo ocular anti-inflammatory efficacy test confirmed an optimal efficacy of NPs and its potential application in eye surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Tiered application of the neutral red release and EpiOcular™ assays for evaluating the eye irritation potential of agrochemical formulations.

    PubMed

    Settivari, Raja S; Amado, Ricardo Acosta; Corvaro, Marco; Visconti, Nicolo R; Kan, Lynn; Carney, Edward W; Boverhof, Darrell R; Gehen, Sean C

    2016-11-01

    Agrochemical formulations have been underrepresented in validation efforts for implementing alternative eye irritation approaches but represent a significant opportunity to reduce animal testing. This study assesses the utility of the neutral red release assay (NRR) and EpiOcular™ assay (EO) for predicting the eye irritation potential of 64 agrochemical formulations relative to Draize data. In the NRR, formulations with an NRR50 value ≤ 50 mg/mL were categorized as UN GHS Cat 1 and those >250 mg/mL were classified as UN GHS Non Classified (NC). The accuracy, sensitivity, and specificity were 78, 85 and 76% and 73, 85 and 61% for identifying UN GHS 1 and NC formulations, respectively. Specificity was poor for formulations with NRR50 > 50 to ≤250 mg/mL. The EO (ET-40 method) was explored to differentiate formulations that were UN GHS 1/2 and UN GHS NC. The EO resulted in accuracy, sensitivity, and specificity of 65%, 58% and 75% for identifying UN GHS NC formulations. To improve the overall performance, the assays were implemented using a tiered-approach where the NRR was run as a first-tier followed by the EO. The tiered-approach resulted in improved accuracy (75%) and balanced sensitivity (73%) and specificity (77%) for distinguishing between irritating and non-irritating agrochemical formulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: skin irritation.

    PubMed

    Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia

    2009-07-01

    Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.

  5. Mechanistic-based non-animal assessment of eye toxicity: Inflammatory profile of human keratinocytes cells after exposure to eye damage/irritant agents.

    PubMed

    da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos

    2018-06-25

    Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential. Copyright © 2018. Published by Elsevier B.V.

  6. Effect of sperminated pullulans on drug permeation through isolated rabbit cornea and determination of ocular irritation.

    PubMed

    Yu, N; Xun, Y; Jin, D; Yang, H; Hang, T; Cui, H

    2010-01-01

    The aim of this study was to investigate the effect of two sperminated pullulans (SP) with a different number of amino groups (SP-L, amino group content 0.124 mmol/g polymer; and SP-H, amino group content 0.578 mmol/g polymer) on the permeation of drugs through isolated rabbit corneas. Determination of corneal hydration levels and Draize eye tests were performed to assess the safety of SP both in vitro and in vivo. For 0.2% (w/v) SP-L and 0.2% (w/v) SP-H, the enhancement ratios (ERs) with dexamethasone of 1.34 and 1.42, respectively, were not statistically significant. For ofloxacin, tobramycin and sodium fluorescein, the ERs with 0.2% SP-L were 1.37, 2.02 and 2.12, respectively, and with 0.2% SP-H the ERs were 1.84, 4.69 and 6.87, respectively; these ERs were all statistically significant. Enhancement increased with increasing amino group content of the SP. The improved transcorneal drug absorption via the paracellular route indicated opening of the tight junctions in the corneal epithelium. Irritation tests indicated that 0.2% SP-L and 0.2% SP-H did not damage the corneal tissues.

  7. A reassessment of the in vitro RBC haemolysis assay with defibrinated sheep blood for the determination of the ocular irritation potential of cosmetic products: comparison with the in vivo Draize rabbit test.

    PubMed

    Alves, Eloísa Nunes; Presgrave, Rosaura de Farias; Presgrave, Octávio Augusto França; Sabagh, Fernanda Peres; de Freitas, João Carlos Borges Rolim; Corrado, Alexandre P

    2008-07-01

    We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (DI); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.

  8. Bioconvective Assay As Alternative To Draize Test

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Matsos, Helen C.

    1993-01-01

    Protocol to determine toxicities of chemicals implemented relatively cheaply by use of equipment and materials packaged in convenient kit form. Tests involve observation of macroscopic patterns formed at high concentrations of free-swimming protozoan species Tetrahymena pyriformis in liquid media. Provides more-sensitive indication of toxicity and costs less. Given that there are no data on toxicities of 70 to 80 percent of commercial chemicals, high cost of, and current opposition to, testing on higher animals, new protocol helps meet pressing need.

  9. Controlled drug delivery for glaucoma therapy using montmorillonite/Eudragit microspheres as an ion-exchange carrier

    PubMed Central

    Tian, Shuangyan; Li, Juan; Tao, Qi; Zhao, Yawen; Lv, Zhufen; Yang, Fan; Duan, Haoyun; Chen, Yanzhong; Zhou, Qingjun; Hou, Dongzhi

    2018-01-01

    Background Glaucoma is a serious eye disease that can lead to loss of vision. Unfortunately, effective treatments are limited by poor bioavailability of antiglaucoma medicine due to short residence time on the preocular surface. Materials and methods To solve this, we successfully prepared novel controlled-release ion-exchange microparticles to deliver betaxolol hydrochloride (BH). Montmorillonite/BH complex (Mt-BH) was prepared by acidification-intercalation, and this complex was encapsulated in microspheres (Mt-BH encapsulated microspheres [BMEMs]) by oil-in-oil emulsion–solvent evaporation method. The BH loaded into ion-exchange Mt was 47.45%±0.54%. After the encapsulation of Mt-BH into Eudragit microspheres, the encapsulation efficiency of BH into Eudragit microspheres was 94.35%±1.01% and BH loaded into Eudragit microspheres was 14.31%±0.47%. Results Both Fourier transform infrared spectra and X-ray diffraction patterns indicated that BH was successfully intercalated into acid-Mt to form Mt-BH and then Mt-BH was encapsulated into Eudragit microspheres to obtain BMEMs. Interestingly, in vitro release duration of the prepared BMEMs was extended to 12 hours, which is longer than both of the BH solution (2.5 hours) and the conventional BH microspheres (5 hours). Moreover, BMEM exhibited lower toxicity than that of BH solution as shown by the results of cytotoxicity tests, chorioallantoic membrane-trypan blue staining, and Draize rabbit eye test. In addition, both in vivo and in vitro preocular retention capacity study of BMEMs showed a prolonged retention time. The pharmacodynamics showed that BMEMs could extend the drug duration of action. Conclusion The developed BMEMs have the potential to be further applied as ocular drug delivery systems for the treatment of glaucoma. PMID:29391798

  10. Controlled drug delivery for glaucoma therapy using montmorillonite/Eudragit microspheres as an ion-exchange carrier.

    PubMed

    Tian, Shuangyan; Li, Juan; Tao, Qi; Zhao, Yawen; Lv, Zhufen; Yang, Fan; Duan, Haoyun; Chen, Yanzhong; Zhou, Qingjun; Hou, Dongzhi

    2018-01-01

    Glaucoma is a serious eye disease that can lead to loss of vision. Unfortunately, effective treatments are limited by poor bioavailability of antiglaucoma medicine due to short residence time on the preocular surface. To solve this, we successfully prepared novel controlled-release ion-exchange microparticles to deliver betaxolol hydrochloride (BH). Montmorillonite/BH complex (Mt-BH) was prepared by acidification-intercalation, and this complex was encapsulated in microspheres (Mt-BH encapsulated microspheres [BMEMs]) by oil-in-oil emulsion-solvent evaporation method. The BH loaded into ion-exchange Mt was 47.45%±0.54%. After the encapsulation of Mt-BH into Eudragit microspheres, the encapsulation efficiency of BH into Eudragit microspheres was 94.35%±1.01% and BH loaded into Eudragit microspheres was 14.31%±0.47%. Both Fourier transform infrared spectra and X-ray diffraction patterns indicated that BH was successfully intercalated into acid-Mt to form Mt-BH and then Mt-BH was encapsulated into Eudragit microspheres to obtain BMEMs. Interestingly, in vitro release duration of the prepared BMEMs was extended to 12 hours, which is longer than both of the BH solution (2.5 hours) and the conventional BH microspheres (5 hours). Moreover, BMEM exhibited lower toxicity than that of BH solution as shown by the results of cytotoxicity tests, chorioallantoic membrane-trypan blue staining, and Draize rabbit eye test. In addition, both in vivo and in vitro preocular retention capacity study of BMEMs showed a prolonged retention time. The pharmacodynamics showed that BMEMs could extend the drug duration of action. The developed BMEMs have the potential to be further applied as ocular drug delivery systems for the treatment of glaucoma.

  11. Cytoprotective effect against UV-induced DNA damage and oxidative stress: role of new biological UV filter.

    PubMed

    Said, T; Dutot, M; Martin, C; Beaudeux, J-L; Boucher, C; Enee, E; Baudouin, C; Warnet, J-M; Rat, P

    2007-03-01

    The majority of chemical solar filters are cytotoxic, particularly on sensitive ocular cells (corneal and conjunctival cells). Consequently, a non-cytotoxic UV filter would be interesting in dermatology, but more especially in ophthalmology. In fact, light damage to the eye can be avoided thanks to a very efficient ocular antioxidant system; indeed, the chromophores absorb light and dissipate its energy. After middle age, a decrease in the production of antioxidants and antioxidative enzymes appears with accumulation of endogenous molecules that are phototoxic. UV radiations can induce reactive oxygen species formation, leading to various ocular diseases. Because most UV filters are cytotoxic for the eye, we investigated the anti-UV properties of Calophyllum inophyllum oil in order to propose it as a potential vehicle, free of toxicity, with a natural UV filter action in ophthalmic formulation. Calophyllum inophyllum oil, even at low concentration (1/10,000, v/v), exhibited significant UV absorption properties (maximum at 300nm) and was associated with an important sun protection factor (18-22). Oil concentrations up to 1% were not cytotoxic on human conjunctival epithelial cells, and Calophyllum inophyllum oil appeared to act as a cytoprotective agent against oxidative stress and DNA damage (85% of the DNA damage induced by UV radiations were inhibited with 1% Calophyllum oil) and did not induce in vivo ocular irritation (Draize test on New Zealand rabbits). Calophyllum inophyllum oil thus exhibited antioxidant and cytoprotective properties, and therefore might serve, for the first time, as a natural UV filter in ophthalmic preparations.

  12. Safety Evaluation of Silk Protein Film (A Novel Wound Healing Agent) in Terms of Acute Dermal Toxicity, Acute Dermal Irritation and Skin Sensitization

    PubMed Central

    Padol, Amol R.; Jayakumar, K.; Shridhar, N. B.; Narayana Swamy, H. D.; Narayana Swamy, M.; Mohan, K.

    2011-01-01

    Acute dermal toxicity study was conducted in rats. The parameters studied were body weight, serum biochemistry and gross pathology. The animals were also observed for clinical signs and mortality after the application of test film. The dermal irritation potential of silk protein film was examined using Draize test. In the initial test, three test patches were applied sequentially for 3 min, 1 and 4 hours, respectively, and skin reaction was graded. The irritant or negative response was confirmed using two additional animals, each with one patch, for an exposure period of 4 hours. The responses were scored at 1, 24, 48 and 72 hours after the patch removal. Skin sensitization study was conducted according to Buehler test in guinea pigs, in which on day 0, 7 and 14, the animals were exposed to test material for 6 hours (Induction phase) and on day 28, the animals were exposed for a period of 24 hours (Challenge phase). The skin was observed and recorded at 24 and 48 hours after the patch removal. In acute dermal toxicity study, the rats dermally treated with silk film did not show any abnormal clinical signs and the body weight, biochemical parameters and gross pathological observations were not significantly different from the control group. In acute dermal irritation study, the treated rabbits showed no signs of erythema, edema and eschar, and the scoring was given as “0” for all time points of observations according to Draize scoring system. In skin sensitization study, there were no skin reactions 24 and 48 hours after the removal of challenge patch, which was scored “0” based on Magnusson/Kligman grading scale. PMID:21430915

  13. Survey of ocular irritation predictive capacity using Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test historical data for 319 personal care products over fourteen years.

    PubMed

    Donahue, D A; Kaufman, L E; Avalos, J; Simion, F A; Cerven, D R

    2011-03-01

    The Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test are widely used to predict ocular irritation potential for consumer-use products. These in vitro assays do not require live animals, produce reliable predictive data for defined applicability domains compared to the Draize rabbit eye test, and are rapid and inexpensive. Data from 304 CAMVA and/or BCOP studies (319 formulations) were surveyed to determine the feasibility of predicting ocular irritation potential for various formulations. Hair shampoos, skin cleansers, and ethanol-based hair styling sprays were repeatedly predicted to be ocular irritants (accuracy rate=0.90-1.00), with skin cleanser and hair shampoo irritation largely dependent on surfactant species and concentration. Conversely, skin lotions/moisturizers and hair styling gels/lotions were repeatedly predicted to be non-irritants (accuracy rate=0.92 and 0.82, respectively). For hair shampoos, ethanol-based hair stylers, skin cleansers, and skin lotions/moisturizers, future ocular irritation testing (i.e., CAMVA/BCOP) can be nearly eliminated if new formulations are systematically compared to those previously tested using a defined decision tree. For other tested product categories, new formulations should continue to be evaluated in CAMVA/BCOP for ocular irritation potential because either the historical data exhibit significant variability (hair conditioners and mousses) or the historical sample size is too small to permit definitive conclusions (deodorants, make-up removers, massage oils, facial masks, body sprays, and other hair styling products). All decision tree conclusions should be made within a conservative weight-of-evidence context, considering the reported limitations of the BCOP test for alcohols, ketones, and solids. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. A new alternative method for testing skin irritation using a human skin model: a pilot study.

    PubMed

    Miles, A; Berthet, A; Hopf, N B; Gilliet, M; Raffoul, W; Vernez, D; Spring, P

    2014-03-01

    Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Conjugation of cell-penetrating peptides with poly(lactic-co-glycolic acid)-polyethylene glycol nanoparticles improves ocular drug delivery

    PubMed Central

    Vasconcelos, Aimee; Vega, Estefania; Pérez, Yolanda; Gómara, María J; García, María Luisa; Haro, Isabel

    2015-01-01

    In this work, a peptide for ocular delivery (POD) and human immunodeficiency virus transactivator were conjugated with biodegradable poly(lactic-co-glycolic acid) (PGLA)–polyethylene glycol (PEG)-nanoparticles (NPs) in an attempt to improve ocular drug bioavailability. The NPs were prepared by the solvent displacement method following two different pathways. One involved preparation of PLGA NPs followed by PEG and peptide conjugation (PLGA-NPs-PEG-peptide); the other involved self-assembly of PLGA-PEG and the PLGA-PEG-peptide copolymer followed by NP formulation. The conjugation of the PEG and the peptide was confirmed by a colorimetric test and proton nuclear magnetic resonance spectroscopy. Flurbiprofen was used as an example of an anti-inflammatory drug. The physicochemical properties of the resulting NPs (morphology, in vitro release, cell viability, and ocular tolerance) were studied. In vivo anti-inflammatory efficacy was assessed in rabbit eyes after topical instillation of sodium arachidonate. Of the formulations developed, the PLGA-PEG-POD NPs were the smaller particles and exhibited greater entrapment efficiency and more sustained release. The positive charge on the surface of these NPs, due to the conjugation with the positively charged peptide, facilitated penetration into the corneal epithelium, resulting in more effective prevention of ocular inflammation. The in vitro toxicity of the NPs developed was very low; no ocular irritation in vitro (hen’s egg test–chorioallantoic membrane assay) or in vivo (Draize test) was detected. Taken together, these data demonstrate that PLGA-PEG-POD NPs are promising vehicles for ocular drug delivery. PMID:25670897

  16. Influence of freeze-drying and γ-irradiation in preclinical studies of flurbiprofen polymeric nanoparticles for ocular delivery using d-(+)-trehalose and polyethylene glycol

    PubMed Central

    Ramos Yacasi, Gladys Rosario; García López, María Luisa; Espina García, Marta; Parra Coca, Alexander; Calpena Campmany, Ana Cristina

    2016-01-01

    This study investigated the suspension of poly(ε-caprolactone) nanoparticles as an ocular delivery system for flurbiprofen (FB-PεCL-NPs) in order to overcome the associated problems, such as stability, sterility, tolerance, and efficacy, with two different FB-PεCL-NP formulations. The formulations were stabilized with poloxamer 188 (1.66% and 3.5%) and submitted individually for freeze-drying and γ-irradiation with polyethylene glycol 3350 (PEG3350) and d-(+)-trehalose (TRE). Both formulations satisfied criteria according to all physicochemical parameters required for ocular pharmaceuticals. The FB-PεCL-NP formulations showed non-Newtonian behavior and sustained drug release. Ex vivo permeation analysis using isolated ocular pig tissues suggested that the presence of PEG3350 results in a reduction of FB transcorneal permeation. Moreover, TRE improved the penetration of FB across the cornea, especially after γ-irradiation. In addition, both formulations did not show a significant affinity in increasing FB transscleral permeation. Both formulations were classified as nonirritating, safe products for ophthalmic administration according to hen’s egg test-chorioallantoic membrane and Draize eye test. Furthermore, an in vivo anti-inflammatory efficacy test showed that irradiated FB-PεCL-NPs prepared with PEG3350 (IR-NPsPEG) have longer anti-inflammatory effects than those presented with irradiated FB-PεCL-NPs prepared with TRE (IR-NPsTRE). IR-NPsPEG showed a suitable physical stability after an aqueous reconstitution over >30 days. This study concludes that both formulations meet the Goldman’s criteria and demonstrate how irradiated nanoparticles, with innovative permeation characteristics, could be used as a feasible alternative to a flurbiprofen solution for ocular application in clinical trials. PMID:27601897

  17. Influence of freeze-drying and γ-irradiation in preclinical studies of flurbiprofen polymeric nanoparticles for ocular delivery using d-(+)-trehalose and polyethylene glycol.

    PubMed

    Ramos Yacasi, Gladys Rosario; García López, María Luisa; Espina García, Marta; Parra Coca, Alexander; Calpena Campmany, Ana Cristina

    This study investigated the suspension of poly(ε-caprolactone) nanoparticles as an ocular delivery system for flurbiprofen (FB-PεCL-NPs) in order to overcome the associated problems, such as stability, sterility, tolerance, and efficacy, with two different FB-PεCL-NP formulations. The formulations were stabilized with poloxamer 188 (1.66% and 3.5%) and submitted individually for freeze-drying and γ-irradiation with polyethylene glycol 3350 (PEG3350) and d-(+)-trehalose (TRE). Both formulations satisfied criteria according to all physicochemical parameters required for ocular pharmaceuticals. The FB-PεCL-NP formulations showed non-Newtonian behavior and sustained drug release. Ex vivo permeation analysis using isolated ocular pig tissues suggested that the presence of PEG3350 results in a reduction of FB transcorneal permeation. Moreover, TRE improved the penetration of FB across the cornea, especially after γ-irradiation. In addition, both formulations did not show a significant affinity in increasing FB transscleral permeation. Both formulations were classified as nonirritating, safe products for ophthalmic administration according to hen's egg test-chorioallantoic membrane and Draize eye test. Furthermore, an in vivo anti-inflammatory efficacy test showed that irradiated FB-PεCL-NPs prepared with PEG3350 (IR-NPsPEG) have longer anti-inflammatory effects than those presented with irradiated FB-PεCL-NPs prepared with TRE (IR-NPsTRE). IR-NPsPEG showed a suitable physical stability after an aqueous reconstitution over >30 days. This study concludes that both formulations meet the Goldman's criteria and demonstrate how irradiated nanoparticles, with innovative permeation characteristics, could be used as a feasible alternative to a flurbiprofen solution for ocular application in clinical trials.

  18. Characterization and evaluation of poly(epsilon-caprolactone) nanoparticles containing 2-ethylhexyl-p-methoxycinnamate, octocrylene, and benzophenone-3 in anti-solar preparations.

    PubMed

    do Nascimento, Débora Freitas; Silva, Anna Claudia; Mansur, Claudia Regina Elias; Presgrave, Rosaura de Faria; Alves, Eloisa Nunes; Silva, Ronald Santos; Ricci-Júnior, Eduardo; de Freitas, Zaida Maria Faria; dos Santos, Elisabete Pereira

    2012-09-01

    Ultraviolet radiation can bring both harm and benefits to human health. Among those harms are erythemas, photosensitivity, photoaging, and the most worrying, skin cancer. Nanoencapsulation of sunscreen agents (SA) by using a biocompatible and biodegradable polymer such as poly(epsilon-caprolactone) (PCL) is advantageous as it increases the retention of UV absorbers in the skin, avoids systemic absorption, and consequently, improves water resistance and stability of the preparation. The aim of this work is to develop, characterize, and study the encapsulation of 3 different SA: 2-ethylhexyl-p-methoxycinnamate, benzophenone-3, and octocrylene in PCL nanoparticles (Nps). Nps were prepared by the solvent emulsification and evaporation method. The process yield was calculated, and the Nps were characterized in terms of size, polydispersity index (PI), morphology, zeta potential (ZP), encapsulation efficiency (EE) (%), and sunscreen agent content (SAC). The final formulations were submitted to the hen's egg test-chorioallantoic membrane (HET-CAM), chorioallantoic membrane-trypan blue staining (CAM-TBS), red blood cell (RBC), Draize tests, in vitro release, in vitro sun protection factor (SPF), UVA protection factor (PF-UVA), and photostability. All the Nps were in the nanometric scale. PI showed monodisperse systems. ZP became more negative as the Np were lyophilized and were added to the formulations. EE varied from 84 to 90%. The SAC went from 44 to 65 microg of sunscreen agents by milligram of Np. The process yield went from 60 to 76%. Nps were predominantly spherical and elliptical forms. The addition of Np diminished the release of the SA. The SPF increased with Np presence and helped to maintain the PF-UVA after irradiation. The HET-CAM assay evaluated the formulation as slightly irritant, CAM-TBS and RBC tests as non irritant, and the Draize test as moderately irritant.

  19. Organic-inorganic hybrid nanocomposites based on chitosan derivatives and layered double hydroxides with intercalated phacolysin as ocular delivery system

    NASA Astrophysics Data System (ADS)

    Qin, Zhiguo; Zhang, Jie; Chi, Huibo; Cao, Feng

    2015-12-01

    This study was mainly aimed to evaluate the potential use of a novel ocular drug delivery system, organic-inorganic hybrid nanocomposites based on chitosan derivatives and layered double hydroxides (LDH). Organic polymers of chitosan-glutathione (CG) and pre-activated chitosan-glutathione (CG-2MNA) were successfully synthesized and characterized. LDH with intercalated phacolysin (PCL), including larger hexagonal LDH-PCL (Lh-LDH-PCL), larger spherical LDH-PCL (Ls-LDH-PCL), smaller hexagonal LDH-PCL (Sh-LDH-PCL), CG hybrid LDH-PCL (LDH-PCL-CG), and CG-2MNA hybrid LDH-PCL (LDH-PCL-CG-2MNA), were prepared. The nanocomposites with particle size of 107.2-274.9 nm were characterized by powder X-ray diffraction, Fourier transform infrared, transmission electron micrographs, etc. In vivo precorneal retention studies showed that the detectable time of all nanocomposites was prolonged from 2 to 6 h in comparison to PCL saline. Accordingly, the AUC0-6h values of Lh-LDH-PCL, Ls-LDH-PCL, Sh-LDH-PCL, LDH-PCL-CG, and LDH-PCL-CG-2MNA nanocomposites were increased by 2.27-, 2.08-, 3.08-, 4.67-, and 3.36-fold, respectively. The Draize test and hematoxylin and eosin staining demonstrated that modified LDH had no eye irritation after single and repeated administration. These results indicated that chitosan derivatives-LDH hybrid nanocomposite dispersion could be a promising ocular drug delivery system to improve precorneal retention time of drugs.

  20. Evaluation of Barrier Skin Cream Effectiveness Against JP-8 Jet Fuel Absorption and Irritation

    DTIC Science & Technology

    2009-04-01

    quantify the colorimeter measurements. This system uses spectral chromaticity coordinates and corresponding color- matching functions based on...in the caudal thigh or lumbar muscles and the rabbit was monitored throughout the procedure. Once anesthetized, a baseline visual and colorimeter ...Visual Scoring Technique All barrier creams were scored in 3 ways; by visual scoring described in the Draize method, by colorimeter , and by

  1. In vitro assessment of skin irritation potential of surfactant-based formulations by using a 3-D skin reconstructed tissue model and cytokine response.

    PubMed

    Walters, Russel M; Gandolfi, Lisa; Mack, M Catherine; Fevola, Michael; Martin, Katharine; Hamilton, Mathew T; Hilberer, Allison; Barnes, Nicole; Wilt, Nathan; Nash, Jennifer R; Raabe, Hans A; Costin, Gertrude-Emilia

    2016-12-01

    The personal care industry is focused on developing safe, more efficacious, and increasingly milder products, that are routinely undergoing preclinical and clinical testing before becoming available for consumer use on skin. In vitro systems based on skin reconstructed equivalents are now established for the preclinical assessment of product irritation potential and as alternative testing methods to the classic Draize rabbit skin irritation test. We have used the 3-D EpiDerm™ model system to evaluate tissue viability and primary cytokine interleukin-1α release as a way to evaluate the potential dermal irritation of 224 non-ionic, amphoteric and/or anionic surfactant-containing formulations, or individual raw materials. As part of our testing programme, two representative benchmark materials with known clinical skin irritation potential were qualified through repeated testing, for use as references for the skin irritation evaluation of formulations containing new surfactant ingredients. We have established a correlation between the in vitro screening approach and clinical testing, and are continually expanding our database to enhance this correlation. This testing programme integrates the efforts of global manufacturers of personal care products that focus on the development of increasingly milder formulations to be applied to the skin, without the use of animal testing. 2016 FRAME.

  2. The effects of sperminated pullulans on cornea permeability to puerarin and the toxicity.

    PubMed

    Yu, Nannan; Dong, Guo; Ge, Hongyan; Jin, Di; Cui, Hao; Liu, Ping

    2012-10-01

    To investigate the varied effects of sperminated pullulans (SP) with different amino residues on cornea permeability and its local toxicity. Three groups of rabbits were used: control, low-amino residue content SP (SP-L), and high-amino residue content SP (SP-H). The in vitro and in vivo spreading assays were combined with high performance liquid chromatography (HPLC) to measure the concentration of puerarin in the external medium or aqueous humor when 0% SP, 0.2% SP-L, and 0.2% SP-H were included. The toxicity of SP was determined by corneal hydration values, Draize score, aqueous humor protein concentration, corneal endothelial evaluation, as well as light microscopy and electron microscopy. The application of 0.2% SP-L and 0.2% SP-H to the cornea in vitro increased puerarin apparent permeability coefficient by 1.96-fold (P<0.05) and 2.95-fold (P<0.01), respectively. SP-H showed stronger effect than SP-L (P<0.05). For the in vivo assay, those were 1.81-fold (P<0.05) and 3.71-fold (P<0.01), respectively. With the SP application, the corneal hydration values were <83% and Draize scores were <4, with no apparent changes in histological observations. SP is one potential adjuvant promoting puerarin permeability to the cornea, and the high-content amino residue SP showed stronger effect, without ocular toxicity.

  3. Catch-up validation study of an in vitro skin irritation test method based on an open source reconstructed epidermis (phase II).

    PubMed

    Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R

    2016-10-01

    To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Evaluation of Ocular Irritation and Bioavailability of Voriconazole Loaded Microemulsion.

    PubMed

    Kumar, Rakesh; Sinha, Vivek Ranjan

    2017-01-01

    Voriconazole (VCZ), a second-generation antifungal with excellent attributes like, broad-spectrum activity, targeted delivery, and tolerability. VCZ loaded microemulsion could be an effective strategy for efficient ocular delivery of the drug. To perform corneal irritation studies and in vivo delivery of VCZ microemulsion to establish its potential as an efficient ocular delivery system. Ocular irritancy was performed by HETCAM (Hen's Egg Test Chorio Allantoic Membrane) assay, corneal histopathology and Draize test. Ex vivo and in vivo studies were performed to determine permeation efficiency of VCZ microemulsion. The irritation studies suggested the non-irritant nature of the microemulsion. The ex vivo studies performed on excised cornea displayed significant enhancement in drug permeation/penetration from microemulsion in contrast to the drug suspension. Further, the in vivo study confirmed the higher availability of VCZ (from microemulsion) in aqueous humor with minimal nasolacrimal drainage (lower plasma drug content) when compared with the drug suspension. The non-irritant nature and high corneal permeation of VCZ encourages the role of microemulsion as a potential ocular delivery system. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Proposal of limit concentrations for skin irritation within the context of a new EEC directive on the classification and labeling of preparations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, G.; Martens, M.; Mosselmans, G.

    1987-12-01

    In this study, solvents belonging to different chemical families were tested for their irritating properties to the skin. The irritating potential of a chemical is expressed as its concentration in a nonirritant diluent beyond which irritation of the skin may be expected in the sense of EEC Directive 79/831/EEC. The substances were applied onto the shaved skin of rabbits by means of a modified Finn chamber for 4 hr. Afterward the exposure chamber was removed and the skin cleaned. Reading of erythema and edema was performed according to the scale of Draize at 1, 24, 48, and 72 hr aftermore » the removal of the patch. On the basis of the readings obtained the different dilutions of the organic solvents tested were classified as irritant or not according to the interpretation rules laid down in EEC Directive 83/467/EEC. On the basis of the structure-activity relationships found within each chemical family the irritation potential of the other members of the family could be derived via interpolation.« less

  6. Selection of non-steroidal anti-inflammatory drug and treatment regimen for sulfur mustard-induced cutaneous lesions.

    PubMed

    Plahovinsak, Jennifer L; Buccellato, Matthew A; Reid, Frances M; Graham, John S

    2016-09-01

    The inflammatory process plays an important role in sulfur mustard (HD) injury and HD pathogenesis, suggesting that anti-inflammatory treatments applied as soon as possible following HD injury may reduce tissue damage and accelerate healing. This study used the HD dermal weanling swine model to investigate the efficacy of two non-steroidal anti-inflammatory drugs, capsaicin and diclofenac, when applied in combination with the steroid, clobetasol. The therapeutic regimen was also investigated with respect to initiation of treatment post-exposure, frequency and duration. Yorkshire-cross pigs were randomly assigned to experimental groups, corresponding to all combinations of treatment (capsaicin with clobetasol or diclofenac with clobetasol), onset time (1, 2 or 4 h post-exposure), treatment duration (1, 3 or 5 days) and frequency of applications (2, 3 or 4 per day). For each animal, two sites on the ventral abdomen were exposed to 400 μL of neat HD for 8 min to achieve superficial dermal (SD) lesions and two sites were exposed to 400 μL neat HD for 30 min to achieve deep dermal (DD) lesions. Each treatment regimen was tested against a SD and a DD injury. Untreated SD and DD lesion sites served as within-animal controls. Assessments, up to one week post-challenge, included digital photographs, clinical assessments (lesion size measurements and modified Draize scoring), transepidermal water loss (TEWL), reflectance colorimetry and histopathologic evaluations that included an estimate for depth of injury and wound healing parameters. Diclofenac plus clobetasol treatment resulted in significant reductions in lesion contracture and modified Draize scores, increased barrier function (decreased TEWL), and increased healing as determined by histopathology for both SD and DD injury when compared with untreated sites and sites treated with capsaicin plus clobetasol. An increased duration of treatment from 1 to 5 days was most commonly associated with decreased clinical assessment and histopathological severity scores. Therefore, a combination of diclofenac and clobetasol application, when administered for at least five days, shows promise in ameliorating HD-induced lesions.

  7. Optimization and physicochemical characterization of a triamcinolone acetonide-loaded NLC for ocular antiangiogenic applications.

    PubMed

    Araújo, J; Gonzalez-Mira, E; Egea, M A; Garcia, M L; Souto, E B

    2010-06-30

    The purpose of this study was to develop a novel nanostructured lipid carrier (NLC) for the intravitreal-targeting delivery of triamcinolone acetonide (TA) by direct ocular instillation. A five-level central composite rotable design was used to study the influence of four different variables on the physicochemical characteristics of NLCs. The analysis of variance (ANOVA) statistical test was used to assess the optimization of NLC production parameters. The systems were produced by high pressure homogenization using Precirol ATO5 and squalene as solid and liquid lipids respectively, and Lutrol F68 as surfactant. Homogenization at 600 bar for 3 cycles of the optimized formulation resulted in the production of small NLC (mean diameter < 200 nm) with a homogeneous particle size distribution (polydispersity index (PI) approximately 0.1), of negatively charged surface (approximately |45| mV) and high entrapment efficiency (approximately 95%). Surface morphology was assessed by SEM which revealed fairly spherical shape. DSC, WAXS and FT-IR analyses confirmed that TA was mostly entrapped into the NLC, characterized by an amorphous matrix. In vivo Draize test showed no signs of ocular toxicity. 2010 Elsevier B.V. All rights reserved.

  8. Are Cosmetics Used in Developing Countries Safe? Use and Dermal Irritation of Body Care Products in Jimma Town, Southwestern Ethiopia

    PubMed Central

    Amasa, Wayessa; Santiago, Dante; Mekonen, Seblework; Ambelu, Argaw

    2012-01-01

    Background. Rabbit skin model was used to test skin irritation of the most commonly used cosmetic products in Jimma town, southwestern Ethiopia. The most commonly used cosmetics were Dove, Glysolid, College, Top Society, Fair and Lovely, Nivea, Lux, Magic fruit world, Solea, Body talk, Kris, Holly, Victoria, and Sweet Heart. Methods. Intact and abraded rabbit skins were tested for erythema and edema under shade and under sun exposure. Draize Primary Irritation Index (PII) was used to calculate skin irritation of each cosmetic. Cosmetic ingredients were analyzed from the labels. Results and Discussion. Only Dove cream caused no skin irritation except for an abraded skin under sun exposure for five consecutive days. It has been identified that application of cosmetics on abraded skin under sunny condition worsens the irritation. Cosmetic labels revealed that most ingredients used in all products were those restricted chemicals due to their adverse health effects. Conclusion. This study has concluded that use of cosmetics under sunshine and also on abraded skin increases skin irritation. Hence, those users who have abraded skin are advised not to apply those cosmetics on continuous basis specifically under sun exposure. PMID:23209460

  9. Schirmer test

    MedlinePlus

    Tear test; Tearing test; Dry eye test; Basal secretion test; Sjögren - Schirmer; Schirmer's test ... used when the eye doctor suspects you have dry eye. Symptoms include dryness of the eyes or excessive ...

  10. Design and ocular tolerance of flurbiprofen loaded ultrasound-engineered NLC.

    PubMed

    Gonzalez-Mira, E; Egea, M A; Garcia, M L; Souto, E B

    2010-12-01

    Packaging small drug molecules, such as non-steroidal anti-inflammatory drugs (NSAIDs) into nanoparticulate systems has been reported as a promising approach to improve the drug's bioavailability, biocompatibility and safety profiles. In the last 20 years, lipid nanoparticles (lipid dispersions) entered the nanoparticulate library as novel carrier systems due to their great potential as an alternative to other systems such as polymeric nanoparticles and liposomes for several administration routes. For ocular instillation nanoparticulate carriers are required to have a low mean particle size, with the lowest polydispersity as possible. The purpose of this work was to study the combined influence of 2-level, 4-factor variables on the formulation of flurbiprofen (FB), a lipophilic NSAID, in lipid carriers currently named as nanostructured lipid carriers (NLC). NLC were produced with stearic acid (SA) and castor oil (CO) stabilized by Tween® 80 (non-ionic surfactant) in aqueous dispersion. A 2(4) full factorial design based on 4 independent variables was used to plan the experiments, namely, the percentage of SA with regard to the total lipid, the FB concentration, the stabilizer concentration, and the storage conditions (i.e., storage temperature). The effects of these parameters on the mean particle size, polydispersity index (PI) and zeta potential (ZP) were investigated as dependent variables. The optimization process was achieved and the best formulation corresponded to the NLC formulation composed of 0.05 (wt%) FB, 1.6 (wt%) Tween® 80 and a 50:50 ratio of SA to CO, with an average diameter of 288 nm, PI 0.245 of and ZP of -29 mV. This factorial design study has proven to be a useful tool in optimizing FB-loaded NLC formulations. Stability of the optimized NLC was predicted using a TurbiScanLab® and the ocular tolerance was assessed in vitro and in vivo by the Eytex® and Draize test, respectively. The developed systems were shown physico-chemically stable with high tolerance for eye instillation. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Vestibular ataxia and its measurement in man

    NASA Technical Reports Server (NTRS)

    Fregly, A. R.

    1974-01-01

    Methods involved in and results obtained with a new comprehensive ataxia test battery are described, and definitions of spontaneous and induced vestibular ataxia in man are given in terms of these findings. In addition, the topic of alcohol-induced ataxia in relation to labyrinth function is investigated. Items in the test battery comprise a sharpened Romberg test, in which the subject stands on the floor with eyes closed and arms folded against his chest, feet heel-to-toe, for 60 seconds; an eyes-open walking test; an eyes-open standing test; an eyes-closed standing test; an eyes-closed on-leg standing test; an eyes-closed walk a line test; an eyes-closed heel-to-toe walking test; and supplementary ataxia tests such as the classical Romberg test.

  12. Corneal ulcers and infections

    MedlinePlus

    ... eye Scratches (abrasions) on the eye surface Severely dry eyes Severe allergic eye disease Various inflammatory disorders Wearing ... response Refraction test Slit-lamp examination Tests for dry eye Visual acuity Blood tests to check for inflammatory ...

  13. Dermatotoxicology: Historical perspective and advances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ngo, Mai A.; Maibach, Howard I., E-mail: MaibachH@derm.ucsf.ed

    2010-03-01

    The fundamental principles underlying the study of dermatotoxicology were developed by Arnold Lehman and John Draize over a half century ago and remain applicable today. This discipline has proven indispensable for addressing the problems associated with skin exposure to chemicals. The 55th anniversary of Lehman's landmark publication on safety factors presents the opportunity to reflect upon the historical beginnings of dermatotoxicology and the role of regulatory policies on the development of this field over the years. The complexity and sheer volume of information that has been collected makes it difficult to comprehensively cover all aspects of this vast discipline. Thismore » overview will touch upon the general concepts of ADME, the various forms of contact dermatitis, and transdermal drug delivery systems. The traditional tests performed in animals and humans to identify allergic or irritant potential of chemicals, in addition to alternative methods such as QSAR modeling will be discussed. The subspecialties of infant and occupational dermatotoxicology, as well as dermatotoxicology of aged and ethnic skin, and skin of the vulva and vagina will also be noted.« less

  14. 16 CFR 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test for eye irritants. 1500.42 Section 1500... eye irritants. (a)(1) Six albino rabbits are used for each test substance. Animal facilities for such... materials that might produce eye irritation. Both eyes of each animal in the test group shall be examined...

  15. Irritant and sensitizing potential of eight surfactants commonly used in skin cleansers: an evaluation of 105 patients.

    PubMed

    Corazza, Monica; Lauriola, Maria Michela; Bianchi, Anna; Zappaterra, Mario; Virgili, Annarosa

    2010-01-01

    Irritation from surfactants contained in detergents is a frequent adverse reaction to cosmetics. Sensitization to surfactants is also possible. In the literature, comparative studies about irritant and sensitizing potential of different surfactants are heterogeneous and inconclusive about the best molecules to use. We compared the irritant and sensitizing potential of some surfactants that are usual components in marketed synthetic detergents (syndets) to obtain practical information regarding commonly used detergents. We patch-tested eight surfactants of the different types (anionic, cationic, amphoteric, and non-ionic) in 105 patients. Assessment of allergic reactions of tested surfactants was carried out in accordance with the recommendations of the International Contact Dermatitis Research Group; assessment of irritant power followed the amended Draize classification. None of the eight surfactants in our series gave positive allergic reactions. Only cocamidopropyl betaine from the Italian standard (Società Italiana di Dermatologia Allergologica, Professionale e Ambientale [SIDAPA]) series gave five positive reactions among 105 patients. None of the eight studied surfactants induced skin irritation. The most tolerated are two new mild anionics (sodium cocoyl glutamate and sodium lauroyl oat amino acids) and an amphoteric agent (disodium cocoamphodiacetate). From this study, we deduce that cosmetic companies' efforts to search for and market new products with very mild surfactants have been generally successful.

  16. Methyl trypsin loaded poly(D,L-lactide-coglycolide) nanoparticles for contact lens care.

    PubMed

    Jimenez, N; Galan, J; Vallet, A; Egea, M A; Garcia, M L

    2010-03-01

    The need of an enzymatic cleaner for soft contact lens care with an improved ocular safety and stability profile led us to evaluate the use of nanoparticles (NPs) of poly(D,L-lactide-coglycolide) (PLGA) and methyl trypsin (MT). NPs were prepared by double emulsion-solvent evaporation technique. A factorial design was performed to select the lactic acid proportion in the copolymer and conditions of the second sonication. The increment in proportion of lactic acid provided higher particle size results. When the time of second sonication was decreased, the entrapment efficiency (EE) increased. PLGA 50:50 NPs were chosen for further development since PLGA 50:50H NPs settled fast with different particle size in the sediment and PLGA 75:25 NPs led to form aggregates. The addition of glycerol to the NPs provided the highest EE of MT (>90%) while the addition of Tetronic 1304 promoted the fast release of enzyme initially and decreased the zeta potential (zeta) up to neutral values after gamma irradiation. NPs are expected to be effective as a lens care cleaner after 3 days or even longer with a very low quantity of enzyme released. Formulations showed an acceptable irritation ocular tolerance after in vitro HET-CAM test and in vivo Draize test. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  17. Structural Neural Substrates of Reading the Mind in the Eyes.

    PubMed

    Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi

    2016-01-01

    The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.

  18. The psychometric properties of the "Reading the Mind in the Eyes" Test: an item response theory (IRT) analysis.

    PubMed

    Preti, Antonio; Vellante, Marcello; Petretto, Donatella R

    2017-05-01

    The "Reading the Mind in the Eyes" Test (hereafter: Eyes Test) is considered an advanced task of the Theory of Mind aimed at assessing the performance of the participant in perspective-takingthat is, the ability to sense or understand other people's cognitive and emotional states. In this study, the item response theory analysis was applied to the adult version of the Eyes Test. The Italian version of the Eyes Test was administered to 200 undergraduate students of both genders (males = 46%). Modified parallel analysis (MPA) was used to test unidimensionality. Marginal maximum likelihood estimation was used to fit the 1-, 2-, and 3-parameter logistic (PL) model to the data. Differential Item Functioning (DIF) due to gender was explored with five independent methods. MPA provided evidence in favour of unidimensionality. The Rasch model (1-PL) was superior to the other two models in explaining participants' responses to the Eyes Test. There was no robust evidence of gender-related DIF in the Eyes Test, although some differences may exist for some items as a reflection of real differences by group. The study results support a one-factor model of the Eyes Test. Performance on the Eyes Test is defined by the participant's ability in perspective-taking. Researchers should cease using arbitrarily selected subscores in assessing the performance of participants to the Eyes Test. Lack of gender-related DIF favours the use of the Eyes Test in the investigation of gender differences concerning empathy and social cognition.

  19. 77 FR 41406 - Evaluation of In Vitro Tests for Identifying Eye Injury Hazard Potential of Chemicals and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Evaluation of In Vitro Tests for Identifying Eye Injury...-animal testing strategies proposed for identifying eye injury hazard potential of chemicals and products... Panel and submission of data from substances tested in in vitro tests for identifying eye injury hazard...

  20. A Clinical Study of Subtype-based Prevalence of Dry Eye.

    PubMed

    Rege, Aditya; Kulkarni, Varsha; Puthran, Neelam; Khandgave, Tejaswini

    2013-10-01

    Dry Eye is a multifactorial disease of the tearfilm and the ocular surface which may be due to reduced tear production or excessive tear evaporation resulting in discomfort, visual disturbance, and tear film instability with a potential damage to the ocular surface. Various population-based studies have been done to find out the prevalence and the magnitude of the problem. Women Health Study reported prevalence of 7.8% after screening 36995 subjects above 49 years by interview. The prevalence reported by Blue Mountain Study was 15.3% .The Beaver Dam Study and Shiphai Eye studies are other studies reporting prevalence of 14.5% and 33.7% respectively. McMonnies questionnaire is a widely used screening instrument for Dry-Eye syndromes with sensitivity reportedly varying between 87% and 98% and specificity between 87% and 97%. Prevalence studies use McMonnie's questionnaire for screening individuals for Dry Eye, whereafter tests like Schirmer's test, Tear Film Break Up Time test, Rose Bengal test, Lissamine Green test and Meibomian Gland Dysfunction test are useful for further evaluation. While these tests help to differentiate the subtypes of Dry Eye such as Lipid Anomaly Dry Eye, Aqueous Tear Deficiency and Mucin Layer Deficiency, however, their sensitivity and specificity has not been widely studied. Additionally, very few studies have reported the prevalence of the various subtypes of Dry Eye. To determine the subtype-based prevalence of Dry Eye, to study the specificity and sensitivity of clinical tests for Dry Eye and to correlate McMonnies questionnaire with Dry Eye tests results. A prospective, cross-sectional, observational study, duly approved by the Institutional Ethics Committee, was conducted from October 2010 to April 2012. A total of 4750 subjects above 18 yrs of age were screened by the McMonnies questionnaire. Respondents having a score greater than 14.5 were subjected to clinical Dry Eye tests. The data obtained was analyzed using chi-square test. p value < 0.005 was considered statistically significant.The specificity and sensitivity of each clinical test was calculated using Schirmer's test as gold standard. The prevalence of Dry Eye was 15.4%, with a female preponderance (p = 0.01) and a significant increase with age above 60 years was noted (p<0.0001). Tear Film Break Up Time was the most reliable test with a good sensitivity (68.85%) and specificity (78.32%). Lipid Anomaly Dry Eye was the most prevalent (14.48%) followed by Aqueous Tear Deficiency (13.36%) and Mucin Layer Deficiency (3.51%). A positive correlation between McMonnies score and severity of Dry Eye was seen. This study suggests that Lipid Layer Anomaly is the most prevalent subtype in Dry Eye. Tear Film Break Up Time test is the most likely test to diagnose mild Dry Eye. McMonies Questionnaire can be effectively used for screening of a large population. Tear Film Break Up Time was found to have better sensitivity as well as specificity than other tests used for diagnosing Dry Eye.

  1. Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers.

    PubMed

    Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri

    2015-01-01

    Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.

  2. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  3. 16 CFR 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., including testing that does not require animals, are presented in the CPSC's animal testing policy set forth... conducted, a sequential testing strategy is recommended to reduce the number of test animals. Additionally... eye irritation. Both eyes of each animal in the test group shall be examined before testing, and only...

  4. A Comparison of Functional and Structural Measures for Identifying Progression of Glaucoma

    PubMed Central

    Xin, Daiyan; Greenstein, Vivienne C.; Ritch, Robert; Liebmann, Jeffrey M.; De Moraes, Carlos Gustavo

    2011-01-01

    Purpose. To compare glaucoma progression by functional and structural tests. Methods. The authors prospectively studied 33 glaucoma patients (55 eyes); 20 eyes (15 patients) had disc hemorrhage, and 35 eyes (18 patients) had exfoliation glaucoma. The following tests were performed at two baseline and three follow-up examinations: frequency doubling perimetry (FDT), 24-2 Humphrey visual fields (HVF), multifocal visual evoked potentials (mfVEP), and optical coherence tomography (OCT). To identify progression, the baseline measurements were averaged and compared to those obtained at the final examination. Stereophotographs of the optic disc were obtained at baseline and compared with those at the final examination. Results. Patients were followed up for 21.1 ± 1.8 months. For HVF there were significant changes in mean deviation (MD) in eight (14.5%) eyes but in pattern standard deviation (P/SD) in only two (3.6%) eyes. For FDT, there were significant changes in MD in 13 (23.6%) eyes. Five eyes showed changes in MD for HVF and FDT. For mfVEP, there was an increase in abnormal points in nine (16.4%) eyes. Six of these eyes did not show significant HVF or FDT changes. For OCT, RNFL average thickness values were significantly decreased in nine (16.4%) eyes. Nine (16.4%) eyes showed progression on stereophotography; four of these eyes did not show significant changes on OCT and functional tests. Conclusions. Each test showed evidence of progression in some eyes. However, agreement among tests and stereophotography regarding which eyes showed progression was poor, illustrating the importance of following up patients with a combination of functional and structural tests. PMID:20847115

  5. Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies

    PubMed Central

    Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.

    2014-01-01

    Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911

  6. Utilisation of eye-care services: the effect of Scotland's free eye examination policy.

    PubMed

    Dickey, Heather; Ikenwilo, Divine; Norwood, Patricia; Watson, Verity; Zangelidis, Alexandros

    2012-12-01

    To examine how the introduction of free eye examinations in Scotland affected people's use of eye care services. Particularly, to assess if more people are now having their eyes examined regularly, and whether there are differences in the way people responded to the policy across socio-economic groups. Using the British Household Panel Survey, eye test uptake and frequency in Scotland is compared to the rest of the UK pre and post policy. Propensity to have eye tests and responsiveness to the policy is compared across socio-economic groups. In addition, using data available from a chain of private ophthalmic opticians, clinical characteristics of eye examination patients are compared pre- and post-policy. There is evidence that suggests that people responded positively to the policy. In particular, a higher percentage of people in Scotland have their eyes tested after the free eye care policy was introduced. Interestingly, the response to the policy varies between the different socio-economic groups. For the highest earners and most educated groups, the proportion of people having an eye test increased more than for those groups with lower income or lower education. Although the policy succeeded in getting more people to have their eyes tested, the socio-economic differences observed suggest that the policy has not reached the more vulnerable segments in society to the same extent, in particular, those with low education and low income. As a result, eye care services utilisation inequalities have widened in Scotland after the free eye care policy was introduced. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. A 10-year follow-up to determine the effect of YAG laser iridotomy on the natural history of pigment dispersion syndrome: a randomized clinical trial.

    PubMed

    Gandolfi, Stefano A; Ungaro, Nicola; Tardini, Maria Grazia; Ghirardini, Stella; Carta, Arturo; Mora, Paolo

    2014-12-01

    Prospective long-term analyses of the role of drug-induced mydriasis and laser peripheral iridotomy (LPI) are needed to identify and manage the eyes of patients with pigment dispersion syndrome (PDS) at risk for progressing to ocular hypertension. To assess the 10-year incidence of increased intraocular pressure (IOP) in the 2 eyes of patients with PDS, with 1 eye that underwent LPI and the other that did not. In a randomized clinical trial in the glaucoma research unit at the University Hospital of Parma, Italy, 72 patients with PDS underwent phenylephrine testing. Of these 72 patients, 29 (58 eyes) tested positive for succeeding IOP elevation, and 43 (59 eyes) tested negative. For the 29 high-risk patients (all in both eyes), one eye was randomly assigned to LPI, and the fellow eye was left untreated. For the 43 low-risk patients, the affected eyes were left untreated. An IOP elevation of 5 mm Hg or higher vs baseline (daily phasing) was considered to be a significant increase (ie, an event). In the high-risk group, 3 of 21 eyes that underwent LPI (14.3%) and 13 of 21 untreated eyes (61.9%) showed an increase in IOP of 5 mm Hg or higher during the follow-up period; 4 of 35 low-risk eyes (11.4%) showed a similar increase. Event-free mean (SD) time was 7.99 (0.43) years for high-risk treated eyes, 3.89 (0.68) years for high-risk untreated eyes, and 7.16 (0.23) years for low-risk eyes. The log-rank test showed the following: P < .001 for treated high-risk eyes vs untreated high-risk eyes, P = .74 for treated high-risk eyes vs low-risk eyes, and P < .001 for untreated high-risk eyes vs low-risk eyes. At the end of the 10-year follow-up, (1) approximately one-third of the whole PDS patient population showed an IOP increase of 5 mm Hg or higher in at least 1 eye; (2) phenylephrine testing identified eyes at high risk for developing IOP elevation; and (3) LPI, when performed on high-risk eyes, reduced the rate of IOP elevation to the same level as the low-risk eyes. clinicaltrials.gov Identifier: NCT01053416.

  8. Minor salivary glands and labial mucous membrane graft in the treatment of severe symblepharon and dry eye in patients with Stevens-Johnson syndrome.

    PubMed

    Sant' Anna, Ana Estela B P P; Hazarbassanov, Rossen M; de Freitas, Denise; Gomes, José Álvaro P

    2012-02-01

    To evaluate minor salivary glands and labial mucous membrane graft in patients with severe symblepharon and dry eye secondary to Stevens-Johnson syndrome (SJS). A prospective, non-comparative, interventional case series of 19 patients with severe symblepharon and dry eye secondary to SJS who underwent labial mucous membrane and minor salivary glands transplantation. A complete ophthalmic examination including the Schirmer I test was performed prior to and following surgery. All patients had a preoperative Schirmer I test value of zero. Nineteen patients with severe symblepharon and dry eye secondary to SJS were included in the study. There was a statistically significant improvement in the best spectacle-corrected visual acuity in eight patients (t test; p=0.0070). Values obtained in the Schirmer I test improved significantly in 14 eyes (73.7%) 6 months following surgery (χ(2) test; p=0.0094). A statistically significant increase in tear production (Schirmer I test) was found in eyes that received more than 10 glands per graft compared with eyes that received fewer glands (χ(2) test; p=0.0096). Corneal transparency improved significantly in 11 (72.2%) eyes and corneal neovascularisation improved significantly in five eyes (29.4%) (McNemar test; p=0.001 and p=0.0005). The symptoms questionnaire revealed improvement in foreign body sensation in 53.6% of the patients, in photophobia in 50.2% and in pain in 54.8% (Kruskal-Wallis test; p=0.0167). Labial mucous membrane and minor salivary glands transplantation were found to constitute a good option for the treatment of severe symblepharon and dry eye secondary to SJS. This may be considered as a step prior to limbal stem cell and corneal transplantation in these patients.

  9. Vitrectomy for the diagnosis and management of uveitis of unknown cause.

    PubMed

    Margolis, Ron; Brasil, Oswaldo F M; Lowder, Careen Y; Singh, Rishi P; Kaiser, Peter K; Smith, Scott D; Perez, Victor L; Sonnie, Christine; Sears, Jonathan E

    2007-10-01

    To determine the diagnostic yield of tests commonly used for vitreous fluid analysis in eyes with suspected intraocular infection or malignancy. Noncomparative interventional case series. Forty-four consecutive patients (45 eyes) treated from 1998 through 2006 with posterior segment inflammation who underwent pars plana vitrectomy for diagnostic purposes. Vitreous specimens obtained via pars plana vitrectomy were analyzed by microbiologic culture, cytologic analysis, and flow cytometry. Diagnostic yield and sensitivity of each test performed on vitreous specimens and visual outcomes of eyes that underwent diagnostic vitrectomy (DVx). Preoperative diagnoses were infection in 15 eyes and malignancy in 30 eyes. Overall, vitreous analysis identified a specific cause in 9 (20%) of 45 eyes. The overall sensitivity of DVx was 63.6%. The sensitivities of individual tests were: culture, 50%; cytologic analysis, 66.7%; and flow cytometry, 83.3%. The yields of diagnostic tests were: culture, 5.7%; cytologic analysis, 14.3%; and flow cytometry, 20.6%. Final diagnoses were infection in 6 eyes, malignancy in 9 eyes, and idiopathic in 30 eyes. Mean visual acuity improved significantly in the first 6 months after DVx. Visual acuity improved in 60% of eyes, with 37.8% of eyes improving by 3 lines or more. Analysis of vitreous fluid by widely available tests is useful in identifying intraocular infection or malignancy. Most patients experienced a substantial improvement in vision.

  10. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    PubMed

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  11. The Matrix Metalloproteinase 9 Point-of-Care Test in Dry Eye.

    PubMed

    Lanza, Nicole L; Valenzuela, Felipe; Perez, Victor L; Galor, Anat

    2016-04-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. However, the subjective symptoms of dry eye poorly correlate to the current gold standard for diagnostic tests, reflecting the need to develop better objective tests for the diagnosis of dry eye. This review considers the role of ocular surface matrix metalloproteinase 9 (MMP-9) in dry eye and the implications of a novel point-of-care test that measures MMP-9 levels, InflammaDry (RPS, Sarasota, FL) on choosing appropriate therapeutic treatments. Published by Elsevier Inc.

  12. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  13. Measuring center of pressure signals to quantify human balance using multivariate multiscale entropy by designing a force platform.

    PubMed

    Huang, Cheng-Wei; Sue, Pei-Der; Abbod, Maysam F; Jiang, Bernard C; Shieh, Jiann-Shing

    2013-08-08

    To assess the improvement of human body balance, a low cost and portable measuring device of center of pressure (COP), known as center of pressure and complexity monitoring system (CPCMS), has been developed for data logging and analysis. In order to prove that the system can estimate the different magnitude of different sways in comparison with the commercial Advanced Mechanical Technology Incorporation (AMTI) system, four sway tests have been developed (i.e., eyes open, eyes closed, eyes open with water pad, and eyes closed with water pad) to produce different sway displacements. Firstly, static and dynamic tests were conducted to investigate the feasibility of the system. Then, correlation tests of the CPCMS and AMTI systems have been compared with four sway tests. The results are within the acceptable range. Furthermore, multivariate empirical mode decomposition (MEMD) and enhanced multivariate multiscale entropy (MMSE) analysis methods have been used to analyze COP data reported by the CPCMS and compare it with the AMTI system. The improvements of the CPCMS are 35% to 70% (open eyes test) and 60% to 70% (eyes closed test) with and without water pad. The AMTI system has shown an improvement of 40% to 80% (open eyes test) and 65% to 75% (closed eyes test). The results indicate that the CPCMS system can achieve similar results to the commercial product so it can determine the balance.

  14. Measuring Center of Pressure Signals to Quantify Human Balance Using Multivariate Multiscale Entropy by Designing a Force Platform

    PubMed Central

    Huang, Cheng-Wei; Sue, Pei-Der; Abbod, Maysam F.; Jiang, Bernard C.; Shieh, Jiann-Shing

    2013-01-01

    To assess the improvement of human body balance, a low cost and portable measuring device of center of pressure (COP), known as center of pressure and complexity monitoring system (CPCMS), has been developed for data logging and analysis. In order to prove that the system can estimate the different magnitude of different sways in comparison with the commercial Advanced Mechanical Technology Incorporation (AMTI) system, four sway tests have been developed (i.e., eyes open, eyes closed, eyes open with water pad, and eyes closed with water pad) to produce different sway displacements. Firstly, static and dynamic tests were conducted to investigate the feasibility of the system. Then, correlation tests of the CPCMS and AMTI systems have been compared with four sway tests. The results are within the acceptable range. Furthermore, multivariate empirical mode decomposition (MEMD) and enhanced multivariate multiscale entropy (MMSE) analysis methods have been used to analyze COP data reported by the CPCMS and compare it with the AMTI system. The improvements of the CPCMS are 35% to 70% (open eyes test) and 60% to 70% (eyes closed test) with and without water pad. The AMTI system has shown an improvement of 40% to 80% (open eyes test) and 65% to 75% (closed eyes test). The results indicate that the CPCMS system can achieve similar results to the commercial product so it can determine the balance. PMID:23966184

  15. Association between eye diagnosis and positive syphilis test results in a large, urban sexually transmitted infection/primary care clinic population.

    PubMed

    Lobo, Ann-Marie; Gao, Yan; Rusie, Laura; Houlberg, Magda; Mehta, Supriya D

    2018-03-01

    In 2015, the Centers for Disease Control and Prevention (CDC) and the American Academy of Ophthalmology (AAO) released clinical advisories on rising cases of ocular syphilis. We examined the association between eye disease and syphilis infection among primary care and sexually transmitted infection (STI) clinic patients attending an urban lesbian, gay, bisexual, transgender (LGBT) health center. We conducted a retrospective medical record review of all patients who underwent syphilis testing at Howard Brown Health between 1 January 2010 and 31 December 2015. Confirmed eye diagnosis was based on International Classification of Diseases, Ninth Revision (ICD-9) diagnosis codes for conjunctivitis, uveitis, keratitis, retinitis, and red eye. Demographic information, syphilis treatment, HIV status, and high-risk behaviors were abstracted. Syphilis diagnosis was defined by available laboratory data (enzyme immunoassay [EIA], rapid plasma reagin [RPR] titer, fluorescent treponemal antibody absorption [FTA-Abs], Treponema pallidum Ab). Multivariable logistic regression with robust variance was used to identify independent associations. During the study period, 71,299 syphilis tests were performed on 30,422 patients. There were 2288 (3.2%) positive syphilis tests. Seventy-seven patients had a confirmed eye diagnosis (0.25%). Patients with eye disease had higher probability of at least one positive syphilis test (33%) compared to those without eye disease (8%) ( p < 0.01). Of patients with eye disease, 77% were men who had sex with men (MSM) and 65% were HIV-positive. Patients with eye disease had 5.97 (95% CI: 3.70, 9.63) higher odds of having syphilis compared to patients without eye disease. When adjusted for age, race, gender/sexual orientation, insurance status, and HIV status, this association between positive syphilis test and eye disease decreased but was still significant (OR 2.00, 95% CI 1.17, 3.41). Patients who present with an eye diagnosis to STI/primary care clinic have a higher probability of positive syphilis tests even after adjusting for other risk factors for syphilis. High-risk patients with eye symptoms should have routine STI testing and in keeping with CDC and AAO recommendations, full ophthalmologic examination.

  16. Survey of eye practitioners' preference of diagnostic tests and treatment modalities for dry eye in Ghana.

    PubMed

    Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame

    2016-12-01

    This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Perceptions and understanding of genetics and genetic eye disease and attitudes to genetic testing and gene therapy in a primary eye care setting.

    PubMed

    Ganne, Pratyusha; Garrioch, Robert; Votruba, Marcela

    2015-03-01

    Genetic eye pathology represents a significant percentage of the causes of blindness in industrialized countries. This study explores the level of understanding and perceptions of genetics and inherited eye diseases and the attitudes to genetic testing and gene therapy. The study was conducted in two parts. Participant groups included were: undergraduate students of optometry, primary eye care professionals and members of the general public. A preliminary study aimed to understand perceptions and to explore the level of knowledge about genetics in general, eye genetics and gene therapy. A second survey was designed to explore attitudes to genetic testing and gene therapy. The majority of participants (82%) perceived genetics as an important science. However, none of them showed a high level of understanding of genetics and inherited eye diseases. Undergraduate students and primary eye care professionals were better informed about inherited eye diseases than the general public (p = 0.001). The majority (80%) across all three groups had a positive attitude to genetic testing and gene therapy. There was a lack of knowledge about the genetic services available among all groups of participants. This calls for serious thinking about the level of dissemination of information about genetics and inherited eye diseases. It shows a broadly supportive attitude to genomic medicine among the public. Improving public awareness and education in inherited eye diseases can improve the utility of genetic testing and therapy.

  18. Structural Correlates of Reading the Mind in the Eyes in Autism Spectrum Disorder.

    PubMed

    Sato, Wataru; Uono, Shota; Kochiyama, Takanori; Yoshimura, Sayaka; Sawada, Reiko; Kubota, Yasutaka; Sakihama, Morimitsu; Toichi, Motomi

    2017-01-01

    Behavioral studies have shown that individuals with autism spectrum disorder (ASD) have impaired ability to read the mind in the eyes. Although this impairment is central to their social malfunctioning, its structural neural correlates remain unclear. To investigate this issue, we assessed Reading the Mind in the Eyes Test, revised version (Eyes Test) and acquired structural magnetic resonance images in adults with high-functioning ASD ( n = 19) and age-, sex- and intelligence quotient-matched typically developing (TD) controls ( n = 19). On the behavioral level, the Eyes Test scores were lower in the ASD group than in the control group. On the neural level, an interaction between group and Eyes Test score was found in the left temporoparietal junction (TPJ). A positive association between the Eyes Test score and gray matter volume of this region was evident in the control group, but not in the ASD group. This finding suggests that the failure to develop appropriate structural neural representations in the TPJ may underlie the impaired ability of individuals with ASD to read the mind in the eyes. These behavioral and neural findings provide support for the theories that impairments in processing eyes and the ability to infer others' mental states are the core symptoms of ASD, and that atypical features in the social brain network underlie such impairments.

  19. Survey of Ophthalmologists Regarding Practice Patterns for Dry Eye and Sjogren Syndrome.

    PubMed

    Bunya, Vatinee Y; Fernandez, Karen B; Ying, Gui-Shuang; Massaro-Giordano, Mina; Macchi, Ilaria; Sulewski, Michael E; Hammersmith, Kristin M; Nagra, Parveen K; Rapuano, Christopher J; Orlin, Stephen E

    2018-01-15

    To survey ophthalmologists about current practice patterns regarding the evaluation of dry eye patients and referrals for a Sjogren syndrome (SS) workup. An online survey was sent to ophthalmologists affiliated with the Scheie Eye Institute or Wills Eye Hospital using REDCap in August 2015. Descriptive statistics were used to summarize the data. Four hundred seventy-four survey invitations were sent out and 101 (21%) ophthalmologists completed the survey. The common traditional dry eye test performed was corneal fluorescein staining (62%) and the most common newer dry eye test performed was tear osmolarity (18%). Half of respondents (51%) refer fewer than 5% of their dry eye patients for SS workups, with 18% reporting that they never refer any patients. The most common reasons for referrals included positive review of systems (60%), severe dry eye symptoms (51%) or ocular signs (47%), or dry eye that is refractory to treatment (42%). The majority (83%) felt that there is a need for an evidence-based standardized screening tool for dry eye patients to decide who should be referred for evaluation for SS. Ophthalmologists continue to prefer the use of traditional dry eye tests in practice, with the most common test being corneal fluorescein staining. There is an underreferral of dry eye patients for SS workups, which is contributing to the continued underdiagnosis of the disease. Most respondents felt that there was a need for an evidence-based standardized screening tool to decide which dry eye patients should be referred for SS evaluations.

  20. [Static posturography versus clinical tests in elderly people with vestibular pathology].

    PubMed

    Ortuño-Cortés, Miguel A; Martín-Sanz, Eduardo; Barona-de Guzmán, Rafael

    2008-01-01

    Balance can be quantified by clinical tests and through instrumental studies. The objective of this paper is to determine the correlation between static posturography and 4 clinical tests of balance in elderly people with vestibular disorders and to identify its capability to discriminate the groups studied. 60 patients with vestibular disorders and 60 healthy subjects performed 4 clinical tests (one leg standing with opened eyes, Timed Up and Go, Tinetti and Berg tests) and a static posturography analysis (NedSVE/IBV system) under 4 conditions: Romberg Test, Eyes Open (REO), Romberg Test, Eyes Closed (REC), Romberg Test on Foam with Eyes Open (RFEO), and Romberg Test on Foam with Eyes Closed (RFEC). RFEO correlated best with the clinical tests and RFEC was the worst. RFEO distinguished between healthy individuals and decompensated patients. RFEO gave the best information about postural balance in the elderly. RFEC was not useful. Static posturography can be useful to distinguish vestibular compensation status.

  1. 16 CFR 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... before testing, and only those animals without eye defects or irritation shall be used. The animal is held firmly but gently until quiet. The test material is placed in one eye of each animal by gently pulling the lower lid away from the eyeball to form a cup into which the test substance is dropped. The...

  2. Color vision deficits and laser eyewear protection for soft tissue laser applications.

    PubMed

    Teichman, J M; Vassar, G J; Yates, J T; Angle, B N; Johnson, A J; Dirks, M S; Thompson, I M

    1999-03-01

    Laser safety considerations require urologists to wear laser eye protection. Laser eye protection devices block transmittance of specific light wavelengths and may distort color perception. We tested whether urologists risk color confusion when wearing laser eye protection devices for laser soft tissue applications. Subjects were tested with the Farnsworth-Munsell 100-Hue Test without (controls) and with laser eye protection devices for carbon dioxide, potassium titanyl phosphate (KTP), neodymium (Nd):YAG and holmium:YAG lasers. Color deficits were characterized by error scores, polar graphs, confusion angles, confusion index, scatter index and color axes. Laser eye protection device spectral transmittance was tested with spectrophotometry. Mean total error scores plus or minus standard deviation were 13+/-5 for controls, and 44+/-31 for carbon dioxide, 273+/-26 for KTP, 22+/-6 for Nd:YAG and 14+/-8 for holmium:YAG devices (p <0.001). The KTP laser eye protection polar graphs, and confusion and scatter indexes revealed moderate blue-yellow and red-green color confusion. Color axes indicated no significant deficits for controls, or carbon dioxide, Nd:YAG or holmium:YAG laser eye protection in any subject compared to blue-yellow color vision deficits in 8 of 8 tested with KTP laser eye protection (p <0.001). Spectrophotometry demonstrated that light was blocked with laser eye protection devices for carbon dioxide less than 380, holmium:YAG greater than 850, Nd:YAG less than 350 and greater than 950, and KTP less than 550 and greater than 750 nm. The laser eye protection device for KTP causes significant blue-yellow and red-green color confusion. Laser eye protection devices for carbon dioxide, holmium:YAG and Nd:YAG cause no significant color confusion compared to controls. The differences are explained by laser eye protection spectrophotometry characteristics and visual physiology.

  3. Objective Methods to Test Visual Dysfunction in the Presence of Cognitive Impairment

    DTIC Science & Technology

    2015-12-01

    the eye and 3) purposeful eye movements to track targets that are resolved. Major Findings: Three major objective tests of vision were successfully...developed and optimized to detect disease. These were 1) the pupil light reflex (either comparing the two eyes or independently evaluating each eye ...separately for retina or optic nerve damage, 2) eye movement based analysis of target acquisition, fixation, and eccentric viewing as a means of

  4. Trustworthy-Looking Face Meets Brown Eyes

    PubMed Central

    Kleisner, Karel; Priplatova, Lenka; Frost, Peter; Flegr, Jaroslav

    2013-01-01

    We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes. PMID:23326406

  5. 76 FR 50220 - Availability of Draft ICCVAM Recommendations on Using Fewer Animals to Identify Chemical Eye...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... Fewer Animals to Identify Chemical Eye Hazards: Revised Criteria Necessary to Maintain Equivalent Hazard... criteria using results from 3-animal tests that would provide eye hazard classification equivalent to... least 1 positive animal in a 3-animal test to identify eye hazards will provide the same or greater...

  6. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    PubMed

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  7. Human Skin Permeation Studies with PPARγ Agonist to Improve Its Permeability and Efficacy in Inflammatory Processes.

    PubMed

    Silva-Abreu, Marcelle; Espinoza, Lupe Carolina; Rodríguez-Lagunas, María José; Fábrega, María-José; Espina, Marta; García, María Luisa; Calpena, Ana Cristina

    2017-11-28

    Rosacea is the most common inflammatory skin disease. It is characterized by erythema, inflammatory papules and pustules, visible blood vessels, and telangiectasia. The current treatment has limitations and unsatisfactory results. Pioglitazone (PGZ) is an agonist of peroxisome proliferator-activated receptors (PPARs), a nuclear receptor that regulates important cellular functions, including inflammatory responses. The purpose of this study was to evaluate the permeation of PGZ with a selection of penetration enhancers and to analyze its effectiveness for treating rosacea. The high-performance liquid chromatography (HPLC) method was validated for the quantitative determination of PGZ. Ex vivo permeation experiments were realized in Franz diffusion cells using human skin, in which PGZ with different penetration enhancers were assayed. The results showed that the limonene was the most effective penetration enhancer that promotes the permeation of PGZ through the skin. The cytotoxicity studies and the Draize test detected cell viability and the absence of skin irritation, respectively. The determination of the skin color using a skin colorimetric probe and the results of histopathological studies confirmed the ability of PGZ-limonene to reduce erythema and vasodilation. This study suggests new pharmacological indications of PGZ and its possible application in the treatment of skin diseases, namely rosacea.

  8. Nanostructured lipid carriers as novel ophthalmic delivery system for mangiferin: improving in vivo ocular bioavailability.

    PubMed

    Liu, Rui; Liu, Zhidong; Zhang, Chengui; Zhang, Boli

    2012-10-01

    The aim of this study was to develop a novel nanostructured lipid carriers (NLCs) system to improve ocular bioavailability of mangiferin (MGN) for the potential treatment of cataract. The physicochemical properties of MGN-loaded NLC (MGN-NLC) formulation were characterized by particle size, polydispersity index, zeta potential, entrapment efficiency, drug loading, morphological property, and crystalline state. in vitro characteristics were investigated by drug release from NLC system, physical stability, and corneal permeation through excised rabbit cornea. Moreover, in vivo ocular tolerability was assessed by a modified Draize test and histological microscopy. Preocular retention capability was evaluated by slit-lamp observation. Pharmacokinetic study in the aqueous humor was performed by microdialysis technique. Transmission electron microscopy depicted spherical and uniform morphology. Differential scanning calorimetry and X-ray diffractometry displayed imperfect crystalline lattice. The optimized MGN-NLC formulation exhibited a sustained drug release with 3 months stability and 4.31-fold increase of in vitro corneal permeation. Furthermore, in vivo studies exhibited a high tolerance in the ocular tissues and prolonged drug retention capacity on the corneal surface. Finally, pharmacokinetic study suggested a 5.69-fold increase of ocular bioavailability compared with MGN solution (MGN-SOL). Therefore, NLC system is a promising approach for ocular delivery of MGN. Copyright © 2012 Wiley Periodicals, Inc.

  9. Hyaluronic acid modified chitosan nanoparticles for effective management of glaucoma: development, characterization, and evaluation.

    PubMed

    Wadhwa, Sheetu; Paliwal, Rishi; Paliwal, Shivani R; Vyas, S P

    2010-05-01

    In clinical practices, solution of dorzolamide hydrochloride (DH) and timolol maléate (TM) is recommended for the treatment of glaucoma. However, low drug-contact time and poor ocular bioavailability of drugs due to drainage of solution, tear turnover and its dilution or lacrimation limits its uses. In addition, systemic absorption of TM may induce undesirable cardiovascular side effects. Chitosan (CS) is a polycationic biodegradable polymer which provides sustained and local delivery of drugs to the ocular sites. Hyaluronic acid (HA) also provides synergistic effect for mucoadhesion in association with chitosan. In the present study, hyaluronic acid modified chitosan nanoparticles (CS-HA-NPs) loaded with TM and DH were developed and characterized. The CS-HA-NPs were evaluated for size, shape, zeta potential, entrapment efficiency, and mucoadhesive strength. The in vitro release study was also performed in PBS pH 7.4. The ocular irritation potential of CS-HA-NPs was estimated using draize test on albino rabbits. A significant reduction in IOP level was obtained using CS-HA-NPs as compared to plain solution of drug and a comparable higher reduction in IOP level was observed as to CS-NPs. These results suggest that HA potentialy enhance the mucoadhesiveness and efficiency of CS-NPs and may be promising carrier for ocular drug delivery.

  10. Clinical correlations of dry eye syndrome and allergic conjunctivitis in Korean children.

    PubMed

    Kim, Tae Hyung; Moon, Nam Ju

    2013-01-01

    Clinical patterns in pediatric patients with dry eye syndrome and allergic conjunctivitis were investigated. Children aged 6 to 15 years with dry eye symptoms were included. Slit-lamp examinations including tear film break-up time, Schirmer's test, and fluorescent staining were performed, and subjective symptoms were investigated. Patients with allergic conjunctivitis were subjected to skin prick tests. Tear film break-up time was shorter and the number of symptoms related to dry eyes was higher in pediatric patients with allergic conjunctivitis than in those without allergic conjunctivitis. Patients with allergic conjunctivitis who had higher numbers of positive allergens on the skin prick test also had shorter tear film break-up time. Because pediatric patients with dry eye syndrome tend to complain less about their symptoms than adult patients, dry eye syndrome is commonly overlooked. This study showed that dry eyes tended to be more severe with the presence of allergic conjunctivitis; the more allergens present, the more severe the dry eyes. More attention should be paid to the treatment of pediatric patients with dry eyes accompanied by allergies. Copyright 2013, SLACK Incorporated.

  11. Eye movement perimetry in glaucoma.

    PubMed

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  12. CON4EI: EpiOcular™ Eye Irritation Test (EpiOcular™ EIT) for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, H; Letasiova, S; Adriaens, E; Guest, R; Willoughby, J A; Drzewiecka, A; Gruszka, K; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested. Copyright © 2017. Published by Elsevier Ltd.

  13. An ancient eye test--using the stars.

    PubMed

    Bohigian, George M

    2008-01-01

    Vision testing in ancient times was as important as it is today. The predominant vision testing in some cultures was the recognition and identification of constellations and celestial bodies of the night sky. A common ancient naked eye test used the double star of the Big Dipper in the constellation Ursa Major or the Big Bear. The second star from the end of the handle of the Big Dipper is an optical double star. The ability to perceive this separation of these two stars, Mizar and Alcor, was considered a test of good vision and was called the "test" or presently the Arab Eye Test. This article is the first report of the correlation of this ancient eye test to the 20/20 line in the current Snellen visual acuity test. This article describes the astronomy, origin, history, and the practicality of this test and how it correlates with the present day Snellen visual acuity test.

  14. The effect of mitomycin C trabeculectomy on the progression of visual field defect in normal-tension glaucoma.

    PubMed

    Hagiwara, Y; Yamamoto, T; Kitazawa, Y

    2000-03-01

    We investigated in a prospective fashion the visual prognosis and complications in normal-tension glaucoma following unilateral trabeculectomy with adjunctive mitomycin C. Trabeculectomy with adjunctive mitomycin C was carried out unilaterally in 21 cases of normal-tension glaucoma. Intraocular pressure (IOP), visual prognosis, and complications were compared between the operated eyes and the non-operated fellow eyes. The follow-up period ranged from 2 to 7 years. The IOP dropped significantly from 14.8+/-1.8 mmHg (mean +/- SD) to 9.6+/-3.9 mmHg in the operated eyes (P=0.0002, Wilcoxon signed-rank test), but did not drop in the non-operated eyes. The mean deviation (MD) was -12.69+/-6.41 dB preoperatively and -14.70+/-5.49 dB at the last clinic visit in the operated eyes, whereas in non-operated eyes it was -7.85+/-5.65 dB and -11.15+/-5.62 dB, respectively. The MD deteriorated significantly in both operated and non-operated eyes (operated eyes P=0.0239, non-operated eyes: P=0.0002; Wilcoxon signed-rank test). The MD slope was -0.37+/-0.60 dB/year and -0.71+/-0.89 dB/year for the operated and non-operated eyes, respectively (P=0.5243, Mann-Whitney U-test). Visual field deterioration was more frequently observed in the non-operated eyes by a pointwise definition of the progression (P<0.05, McNemar test). Visual acuity deteriorated in 6 of the operated eyes and in 5 of the non-operated eyes. Cataract developed in 6 (29%) of the 21 operated eyes, while among the non-operated eyes 4 (19%) developed cataract. Mitomycin C trabeculectomy is effective in delaying progression of visual field defect in normal-tension glaucoma, but complications may arise and cause some visual disturbance.

  15. Influence of Eye Movements, Auditory Perception, and Phonemic Awareness in the Reading Process

    ERIC Educational Resources Information Center

    Megino-Elvira, Laura; Martín-Lobo, Pilar; Vergara-Moragues, Esperanza

    2016-01-01

    The authors' aim was to analyze the relationship of eye movements, auditory perception, and phonemic awareness with the reading process. The instruments used were the King-Devick Test (saccade eye movements), the PAF test (auditory perception), the PFC (phonemic awareness), the PROLEC-R (lexical process), the Canals reading speed test, and the…

  16. Improvement in conduction velocity after optic neuritis measured with the multifocal VEP.

    PubMed

    Yang, E Bo; Hood, Donald C; Rodarte, Chris; Zhang, Xian; Odel, Jeffrey G; Behrens, Myles M

    2007-02-01

    To test the efficacy of the multifocal visual evoked potential (mfVEP) technique after long-term latency changes in optic neuritis (ON)/multiple sclerosis (MS), mfVEPs were recorded in 12 patients with ON/MS. Sixty local VEP responses were recorded simultaneously. mfVEP was recorded from both eyes of 12 patients with ON/MS. Patients were tested twice after recovery from acute ON episodes, which occurred in 14 of the 24 eyes. After recovery, all eyes had 20/20 or better visual acuity and normal visual fields as measured with static automated perimetry (SAP). The time between the two postrecovery tests varied from 6 to 56 months. Between test days, the visual fields obtained with SAP remained normal. Ten of the 14 affected eyes showed improvement in median latency on the mfVEP. Six of these eyes fell at or below (improved latency) the 96% confidence interval for the control eyes. None of the 10 initially unaffected eyes fell below the 96% lower limit. Although the improvement was widespread across the field, it did not include all regions. For the six eyes showing clear improvement, on average, 78% of the points had latencies that were shorter on test 2 than on test 1. A substantial percentage of ON/MS patients show a long-term improvement in conduction velocity. Because this improvement can be local, the mfVEP should allow these improvements to be monitored in patients with ON/MS.

  17. Watertight cataract incision closure using fibrin tissue adhesive.

    PubMed

    Hovanesian, John A; Karageozian, Vicken H

    2007-08-01

    To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.

  18. [Investigation of color vision in acute unilateral optic neuritis using a web-based color vision test].

    PubMed

    Kuchenbecker, J; Blum, M; Paul, F

    2016-03-01

    In acute unilateral optic neuritis (ON) color vision defects combined with a decrease in visual acuity and contrast sensitivity frequently occur. This study investigated whether a web-based color vision test is a reliable detector of acquired color vision defects in ON and, if so, which charts are particularly suitable. In 12 patients with acute unilateral ON, a web-based color vision test ( www.farbsehtest.de ) with 25 color plates (16 Velhagen/Broschmann and 9 Ishihara color plates) was performed. For each patient the affected eye was tested first and then the unaffected eye. The mean best-corrected distance visual acuity (BCDVA) in the ON eye was 0.36 ± 0.20 and 1.0 ± 0.1 in the contralateral eye. The number of incorrectly read plates correlated with the visual acuity. For the ON eye a total of 134 plates were correctly identified and 166 plates were incorrectly identified, while for the disease-free fellow eye, 276 plates were correctly identified and 24 plates were incorrectly identified. Both of the blue/yellow plates were identified correctly 14 times and incorrectly 10 times using the ON eye and exclusively correctly (24 times) using the fellow eye. The Velhagen/Broschmann plates were incorrectly identified significantly more frequently in comparison with the Ishihara plates. In 4 out of 16 Velhagen/Broschmann plates and 5 out of 9 Ishihara plates, no statistically significant differences between the ON eye and the fellow eye could be detected. The number of incorrectly identified plates correlated with a decrease in visual acuity. Red/green and blue/yellow plates were incorrectly identified significantly more frequently with the ON eye, while the Velhagen/Broschmann color plates were incorrectly identified significantly more frequently than the Ishihara color plates. Thus, under defined test conditions the web-based color vision test can also be used to detect acquired color vision defects, such as those caused by ON. Optimization of the test by altering the combination of plates may be a useful next step.

  19. The Relation of Ocular Surface Irregularity and Visual Disturbance in Early Stage Acanthamoeba Keratitis.

    PubMed

    Matsumoto, Yukihiro; Kodama, Asako; Goto, Eiki; Kawakita, Tetsuya; Dogru, Murat; Tsubota, Kazuo

    2017-01-01

    To evaluate the relation between ocular surface irregularity and visual disturbance in early stage Acanthamoeba keratitis (AK). Fifteen patients with culture-proven AK underwent routine ophthalmic examinations, including best-corrected visual acuity (BCVA) measurement, slitlamp biomicroscope examination, and corneal fluorescein dye staining test, in both the eyes. We also evaluated the corneal sensitivity with Cochet-Bonnet esthesiometer, tear functions by Schirmer's test, and ocular surface irregularity by corneal topography and compared the results with the contralateral healthy eyes in this study. The mean logarithm of the minimum angle of resolution BCVA (0.71±0.77) was significantly lower in the eyes with AK (P=0.002). Epithelial disorders were present in all eyes, and radial keratoneuritis in 14 eyes (93.3%). The mean corneal sensitivity (39.3±24.1 mm) was significantly lower in eyes with AK compared with the healthy eyes (P=0.005). The mean Schirmer's test value (22.5±12.0 mm) in eyes with AK was significantly higher compared with the healthy eyes (P=0.01). The ocular surface irregularity indices (the surface regularity index, 2.47±0.42; the surface asymmetry index, 3.24±1.31) were significantly higher in eyes with AK compared with contralateral healthy eyes (P<0.0001 and P<0.0001, respectively). The ocular surface disease in AK is associated with decrease in corneal sensitivity and increase in Schirmer's test value and ocular surface irregularity indices. The visual disturbance in AK may owe not only to corneal haze but also to ocular surface irregularity.

  20. [The 8-year follow-up study for clinical diagnostic potentials of frequency-doubling technology perimetry for perimetrically normal eyes of open-angle glaucoma patients with unilateral visual field loss].

    PubMed

    Fan, X; Wu, L L; Xiao, G G; Ma, Z Z; Liu, F

    2018-03-11

    Objective: To analyze potentials of frequency-doubling technology perimetry (FDP) for diagnosing open-angle glaucoma (OAG) in perimetrically normal eyes of OAG patients diagnosed with standard automated perimetry (SAP) and relating factors from abnormalities on FDP to visual field loss on SAP. Methods: A prospective cohort study. Sixty-eight eyes of 68 OAG patients visiting the ophthalmic clinic of Peking University Third Hospital during November 2003 and October 2007 [32 primary open-angle glaucoma patients and 36 normal tension glaucoma patients, 32 males and 36 females, with an average age of (59±13) years] with unilateral field loss detected by SAP (Octopus101 tG2 program) were examined with the FDP N-30 threshold program (Humphrey Instruments) at baseline. Two groups, FDP positive group and FDP negative group, were divided based on the FDP results, and visual field examinations were followed by a series of SAP examinations for the perimetrically normal eyes over 8 years. During the follow-up, the difference of the converting rate of SAP tests between the two groups was analyzed. Differences between "convertors" and "non-convertors" of SAP tests in the FDP positive group, such as the cup-to-disk ratio and glaucomatous optic neuropathy rate, were also compared with the independent-sample t test or Wilcoxon two-sample test for continuous variable data and the χ(2) test or Fisher exact test for classified variable data and rates. Results: Forty-eight perimetrically normal eyes of 48 participants had complete data and a qualifying follow-up. Baseline FDP results were positive in 33 eyes and negative in 15 eyes. Of the eyes with positive FDP results, 22 eyes developed abnormal SAP results after 4.0 to 90.0 months (median 14.5 months) , whereas none of the eyes with negative FDP results developed abnormal SAP results. For perimetrically normal eyes in the FDP positive group, "converters" showed a greater cup-to-disk ratio (0.73±0.09 vs . 0.63±0.14, Wilcoxon two-sample test, P= 0.011) and more eyes with glaucomatous optic neuropathy (19/22 vs . 4/11, Fisher exact test, P= 0.006). Conclusions: In perimetrically normal eyes of OAG patients, FDP could detect visual field loss of these eyes and predict to some extent future visual field loss on SAP. Severity of glaucomatous optic neuropathy at baseline is related to converting from abnormalities on FDP to visual field loss on SAP. (Chin J Ophthalmol, 2018, 54: 177-183) .

  1. [Analysis of risk factors for dry eye syndrome in visual display terminal workers].

    PubMed

    Zhu, Yong; Yu, Wen-lan; Xu, Ming; Han, Lei; Cao, Wen-dong; Zhang, Hong-bing; Zhang, Heng-dong

    2013-08-01

    To analyze the risk factors for dry eye syndrome in visual display terminal (VDT) workers and to provide a scientific basis for protecting the eye health of VDT workers. Questionnaire survey, Schirmer I test, tear break-up time test, and workshop microenvironment evaluation were performed in 185 VDT workers. Multivariate logistic regression analysis was performed to determine the risk factors for dry eye syndrome in VDT workers after adjustment for confounding factors. In the logistic regression model, the regression coefficients of daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and female gender on the results of Schirmer I test were 0.153, 0.548, 0.400, 0.796, 0.234, 0.516, 0.559, and -0.685, respectively; the regression coefficients of daily mean time of exposure to screen, parallel screen-eye angle, upward screen-eye angle, age, working years, and female gender on tear break-up time were 0.021, 0.625, 2.652, 0.749, 0.403, and 1.481, respectively. Daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and working years are risk factors for dry eye syndrome in VDT workers.

  2. SacLab: A toolbox for saccade analysis to increase usability of eye tracking systems in clinical ophthalmology practice.

    PubMed

    Cercenelli, Laura; Tiberi, Guido; Corazza, Ivan; Giannaccare, Giuseppe; Fresina, Michela; Marcelli, Emanuela

    2017-01-01

    Many open source software packages have been recently developed to expand the usability of eye tracking systems to study oculomotor behavior, but none of these is specifically designed to encompass all the main functions required for creating eye tracking tests and for providing the automatic analysis of saccadic eye movements. The aim of this study is to introduce SacLab, an intuitive, freely-available MATLAB toolbox based on Graphical User Interfaces (GUIs) that we have developed to increase the usability of the ViewPoint EyeTracker (Arrington Research, Scottsdale, AZ, USA) in clinical ophthalmology practice. SacLab consists of four processing modules that enable the user to easily create visual stimuli tests (Test Designer), record saccadic eye movements (Data Recorder), analyze the recorded data to automatically extract saccadic parameters of clinical interest (Data Analyzer) and provide an aggregate analysis from multiple eye movements recordings (Saccade Analyzer), without requiring any programming effort by the user. A demo application of SacLab to carry out eye tracking tests for the analysis of horizontal saccades was reported. We tested the usability of SacLab toolbox with three ophthalmologists who had no programming experience; the ophthalmologists were briefly trained in the use of SacLab GUIs and were asked to perform the demo application. The toolbox gained an enthusiastic feedback from all the clinicians in terms of intuitiveness, ease of use and flexibility. Test creation and data processing were accomplished in 52±21s and 46±19s, respectively, using the SacLab GUIs. SacLab may represent a useful tool to ease the application of the ViewPoint EyeTracker system in clinical routine in ophthalmology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. The isolated chicken eye test as a suitable in vitro method for determining the eye irritation potential of household cleaning products.

    PubMed

    Schutte, K; Prinsen, M K; McNamee, P M; Roggeband, R

    2009-08-01

    Eye irritation is an important endpoint in the safety evaluation of consumer products and their ingredients. Several in vitro methods have been developed and are used by different industry sectors to assess eye irritation. One such in vitro method in use for some time already is the isolated chicken eye test (ICE). This investigation focuses on assessing the ICE as a method to determine the eye irritation potential of household cleaning products, both for product safety assurance prior to marketing and for classification and labeling decisions. The ICE involves a single application of test substances onto the cornea of isolated chicken eyes. Endpoints are corneal swelling, corneal opacity and fluorescein retention. The ICE results were compared to historic LVET data in this study due to availability of such in vivo data and the ability to correlate LVET to human experience data on the outcome of accidental exposures to household cleaning products in general. The results of this study indicate that the ICE test is a useful in vitro method for evaluating the eye irritation/corrosion potential and establishing classification and labeling for household cleaning products. For new product formulations, it is best used as part of a weight-of-evidence approach and benchmarked against data from comparable formulations with known eye irritation/corrosion profiles and market experience.

  4. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    PubMed

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Eye vision system using programmable micro-optics and micro-electronics

    NASA Astrophysics Data System (ADS)

    Riza, Nabeel A.; Amin, M. Junaid; Riza, Mehdi N.

    2014-02-01

    Proposed is a novel eye vision system that combines the use of advanced micro-optic and microelectronic technologies that includes programmable micro-optic devices, pico-projectors, Radio Frequency (RF) and optical wireless communication and control links, energy harvesting and storage devices and remote wireless energy transfer capabilities. This portable light weight system can measure eye refractive powers, optimize light conditions for the eye under test, conduct color-blindness tests, and implement eye strain relief and eye muscle exercises via time sequenced imaging. Described is the basic design of the proposed system and its first stage system experimental results for vision spherical lens refractive error correction.

  6. Dry Eye Following Phacoemulsification Surgery and its Relation to Associated Intraoperative Risk Factors.

    PubMed

    Sahu, P K; Das, G K; Malik, Aman; Biakthangi, Laura

    2015-01-01

    The purpose was to study dry eye following phacoemulsification surgery and analyze its relation to associated intra-operative risk factors. A prospective observational study was carried out on 100 eyes of 100 patients without preoperative dry eye. Schirmer's Test I, tear meniscus height, tear break-up time, and lissamine green staining of cornea and conjunctiva were performed preoperatively and at 5 days, 10 days, 1-month, and 2 months after phacoemulsification surgery, along with the assessment of subjective symptoms, using the dry eye questionnaire. The correlations between these values and the operating microscope light exposure time along with the cumulative dissipated energy (CDE) were investigated. There was a significant deterioration of all dry eye test values following phacoemulsification surgery along with an increase in subjective symptoms. These values started improving after 1-month postoperatively, but preoperative levels were not achieved till 2 months after surgery. Correlations of dry eye test values were noted with the operating microscope light exposure time and CDE, but they were not significant. Phacoemulsification surgery is capable of inducing dry eye, and patients should be informed accordingly prior to surgery. The clinician should also be cognizant that increased CDE can induce dry eyes even in eyes that were healthy preoperatively. In addition, intraoperative exposure to the microscopic light should be minimized.

  7. Severity of dry eye syndrome is related to anti-dsDNA autoantibody in systemic lupus erythematosus patients without secondary Sjogren syndrome: A cross-sectional analysis.

    PubMed

    Chen, Alexander; Chen, Hung-Ta; Hwang, Yih-Hsiou; Chen, Yi-Tsun; Hsiao, Ching-Hsi; Chen, Hung-Chi

    2016-07-01

    There are as many as one-third of the systemic lupus erythematosus (SLE) patients who suffer from dry eye syndrome. To this date, dry eye syndrome in SLE patients is believed to be caused by secondary Sjogren syndrome (sSS). However, there is increasing evidence for possible independency of dry eye syndrome and sSS in patients suffering from autoimmune diseases. The purpose of this retrospective observational case series was to identify SLE patients without sSS who had dry eye syndrome, examine the correlation of different autoantibodies and dry eye severity, and determine the cause of dry eye in these patients.We included 49 consecutive SLE patients with dry eye who visited our dry eye clinic. In order to rule out sSS, these patients were all negative for anti-Sjogren's-syndrome-related antigen A and B (anti-SSA/SSB) and had no oral symptoms. Each patient's lupus activity was determined by serological tests including antidouble-stranded DNA antibody (anti-dsDNA), complement levels (C3, C4), erythrocyte sedimentation rate (ESR), and antinuclear antibody (ANA). Severity of dry eye syndrome was determined by corneal sensation (KSen), superficial punctuate keratopathy (SPK), Schirmer-I test (Schirmer), and tear film break-up time (TBUT). The autoantibodies and the dry eye parameters in each group were tested using the χ test or the Mann-Whitney U test for normally distributed or skewed data, respectively.The anti-dsDNA showed significant correlations with KSen (P < 0.001), SPK (P < 0.001), and Schirmer (P = 0.042) but not TBUT. The C3 showed significant correlations with KSen (P < 0.001), SPK (P < 0.001), and Schirmer (P = 0.014) but not TBUT. No correlations of dry eye parameters were observed between C4, ESR, and ANA.The major finding of this study was that the severity of dry eye syndrome in SLE patients without sSS was strongly correlated with anti-dsDNA and C3 but not with C4, ESR, and ANA.

  8. Severity of dry eye syndrome is related to anti-dsDNA autoantibody in systemic lupus erythematosus patients without secondary Sjogren syndrome

    PubMed Central

    Chen, Alexander; Chen, Hung-Ta; Hwang, Yih-Hsiou; Chen, Yi-Tsun; Hsiao, Ching-Hsi; Chen, Hung-Chi

    2016-01-01

    Abstract There are as many as one-third of the systemic lupus erythematosus (SLE) patients who suffer from dry eye syndrome. To this date, dry eye syndrome in SLE patients is believed to be caused by secondary Sjogren syndrome (sSS). However, there is increasing evidence for possible independency of dry eye syndrome and sSS in patients suffering from autoimmune diseases. The purpose of this retrospective observational case series was to identify SLE patients without sSS who had dry eye syndrome, examine the correlation of different autoantibodies and dry eye severity, and determine the cause of dry eye in these patients. We included 49 consecutive SLE patients with dry eye who visited our dry eye clinic. In order to rule out sSS, these patients were all negative for anti-Sjogren's-syndrome-related antigen A and B (anti-SSA/SSB) and had no oral symptoms. Each patient's lupus activity was determined by serological tests including antidouble-stranded DNA antibody (anti-dsDNA), complement levels (C3, C4), erythrocyte sedimentation rate (ESR), and antinuclear antibody (ANA). Severity of dry eye syndrome was determined by corneal sensation (KSen), superficial punctuate keratopathy (SPK), Schirmer-I test (Schirmer), and tear film break-up time (TBUT). The autoantibodies and the dry eye parameters in each group were tested using the χ2 test or the Mann–Whitney U test for normally distributed or skewed data, respectively. The anti-dsDNA showed significant correlations with KSen (P < 0.001), SPK (P < 0.001), and Schirmer (P = 0.042) but not TBUT. The C3 showed significant correlations with KSen (P < 0.001), SPK (P < 0.001), and Schirmer (P = 0.014) but not TBUT. No correlations of dry eye parameters were observed between C4, ESR, and ANA. The major finding of this study was that the severity of dry eye syndrome in SLE patients without sSS was strongly correlated with anti-dsDNA and C3 but not with C4, ESR, and ANA. PMID:27428227

  9. The Reliability, Validity, and Normative Data of Interpupillary Distance and Pupil Diameter Using Eye-Tracking Technology

    PubMed Central

    Murray, Nicholas P.; Hunfalvay, Melissa; Bolte, Takumi

    2017-01-01

    Purpose The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted. PMID:28685104

  10. An Evaluation of the "Reading the Mind in the Eyes-Test" with Seventh to Ninth Graders

    ERIC Educational Resources Information Center

    Müller, Christoph Michael; Gmünder, Lena

    2014-01-01

    Individuals with autism spectrum disorders are often considered to have difficulty with using facial cues (e.g., cues from the eye region) to understand others' mental states. One of the pioneering assessments to test competence in this skill is the "Reading the Mind in the Eyes-Test" (RMET). In order to find out more about the…

  11. Comparison of the Handy Eye Chart and the Lea Symbols Chart in a population of deaf children aged 7–18 years

    PubMed Central

    Gorham, John Paul; Bruce, Beau B.; Hutchinson, Amy K.

    2016-01-01

    Purpose To compare the results of visual acuity testing in a population of deaf children using the Handy Eye Chart versus the Lea Symbols Chart and to compare testability and preference between charts. Methods A total of 24 participants were recruited at the Atlanta Area School for the Deaf. Visual Acuity was evaluated using the Handy Eye Chart and the Lea Symbols Chart. Patient preference and duration of testing were measured. Results The mean difference between the visual acuity as measured by each chart was –0.02 logMAR (95% CI, −0.06 to 0.03). Testing with the Handy Eye Chart was an average of 13.79 seconds faster than testing with the Lea Symbols Chart (95% CI, 1.1–26.47; P = 0.03). Of the 24 participants, 17 (71%) preferred the Handy Eye Chart (95% CI: 49%–87%; P = 0.07). Conclusions The Handy Eye Chart is a fast, valid, and preferred tool for measuring visual acuity in deaf children age 7–18 years. Additional research is needed to evaluate the utility of the Handy Eye Chart in younger children and deaf adults. PMID:27164427

  12. 16 CFR § 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... before testing, and only those animals without eye defects or irritation shall be used. The animal is... substances, including testing that does not require animals, are presented in the CPSC's animal testing... conducted, a sequential testing strategy is recommended to reduce the number of test animals. Additionally...

  13. Toward building an anatomically correct solid eye model with volumetric representation of retinal morphology

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Rowe, T. Scott; Fuller, Alfred R.; Hamann, Bernd; Werner, John S.

    2010-02-01

    An accurate solid eye model (with volumetric retinal morphology) has many applications in the field of ophthalmology, including evaluation of ophthalmic instruments and optometry/ophthalmology training. We present a method that uses volumetric OCT retinal data sets to produce an anatomically correct representation of three-dimensional (3D) retinal layers. This information is exported to a laser scan system to re-create it within solid eye retinal morphology of the eye used in OCT testing. The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power to that of the human eye (~58D). Additionally we tested a water bath eye model from Eyetech Ltd. with a customized retina consisting of five layers of ~60 μm thick biaxial polypropylene film and hot melt rubber adhesive.

  14. Prevalence of dry eye syndrome in residents of surgical specialties.

    PubMed

    Castellanos-González, José Alberto; Torres-Martínez, Verónica; Martínez-Ruiz, Adriana; Fuentes-Orozco, Clotilde; Rendón-Félix, Jorge; Irusteta-Jiménez, Leire; Márquez-Valdez, Aída Rebeca; Cortés-Lares, José Antonio; González-Ojeda, Alejandro

    2016-07-16

    The aim of this study was to determine the prevalence and severity of dry eye syndrome in a group of Mexican residents of different surgical specialties. A cross-sectional descriptive study where the residents were studied using the Ocular Surface Disease Index, together with diagnostic tests for dry eye syndrome, such as tear breakup time, Oxford Schema, Schirmer's test I, and meibomian gland dysfunction testing. Statistical analyses were performed by Pearson's chi-squared test for categorical variables and student's t-test for quantitative variables. Any P value < 0.05 was considered statistically significant. One hundred and twenty-three residents were included (246 eyes); 90 (73 %) were male and 33 (27 %) were female. The mean age was 27.8 ± 2.1 years. A higher number of residents with dry eye syndrome was found in the cardiothoracic surgery (75 %) and otorhinolaryngology (71 %) specialties; 70 % of them reported ocular symptoms, with teardrop quality involvement in >50 % of them. We found a prevalence of 56 % for mild-to-moderate/severe stages of the condition. Their presence in the operating room predisposes surgical residents to dry eye syndrome because of environmental conditions.

  15. Eye-closure-triggered paroxysmal activity and cognitive impairment: a case report.

    PubMed

    Termine, Cristiano; Rubboli, Guido; Veggiotti, Pierangelo

    2006-01-01

    To study the neuropsychological status of an epileptic patient presenting with epileptic activity triggered by eye closure in a 14-year follow-up period. The patient was studied at 12 and 26 years of age; during this period he underwent periodical clinical evaluations and EEG investigations; brain magnetic resonance imaging (MRI) was performed at 12 years of age. A neuropsychological assessment was carried out both at 12 years of age (T0) and at 26 years of age. At T0 and T1, neuropsychological tests (digits and words span, graphoestesia, reactions time to auditory stimuli, sentences repetition, words repetition, digital gnosis, backward counting [i.e.,100-0]) were performed during video-EEG monitoring either with eyes closed or with eyes open, to evaluate possible transitory effects related to ongoing epileptic activity. Moreover, at T0 the patient underwent Wechsler Intelligence Scale for Children-Revised, and at T1 to Wechsler Adult Intelligence Scale-Revised. EEG recordings showed continuous epileptic activity triggered by eye closure, disappearing only with eyes opening, both at T0 and T1 (in this latter case, anteriorly predominant). The results of neuropsychological assessment during eyes closed as compared to performances with eyes open did not show significant differences, at T0 as well as at T1. Wechsler Intelligence scales showed a deterioration of performances at T1 with respect to T0; in addition, at T1, attention and short-term memory abnormalities, impairment in facial recognition and block design, and defective results in Continuous Performance Test and Wisconsin Card Sorting Test were observed. Lack of differences between the results of neuropsychological tests performed with eyes closed as compared to the eyes open condition suggests that in our patient epileptic activity did not cause transitory cognitive abnormalities. Deterioration of Wechsler Intelligence Scales in the follow-up period might be interpreted as the result of a disruption of cognitive processes possibly related to the persistence of a continuous epileptic activity during eye closure over the years. We speculate whether a dysfunction in posterior cortical areas involved in visual processing might be related to the impairment in face recognition and block design tests as well to eye closure sensitivity.

  16. The diagnostic value and accuracy of conjunctival impression cytology, dry eye symptomatology, and routine tear function tests in computer users.

    PubMed

    Bhargava, Rahul; Kumar, Prachi; Kaur, Avinash; Kumar, Manjushri; Mishra, Anurag

    2014-07-01

    To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. A case-control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R (2)) of 0.5 or more was statistically significant. The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls (P < 0.001). Mean TBUT, Schirmer's test values, and goblet cell density were significantly reduced in computer users (P < 0.001). TBUT, Schirmer's, and CIC were abnormal in 48.5%, 29.1%, and 38.4% symptomatic computer users respectively as compared to 8%, 6.7%, and 7.3% symptomatic controls respectively. On correlation analysis, there was a significant (inverse) association of dry eye symptoms (DESS) with TBUT and CIC scores (R (2) > 0.5), in contrast to Schirmer's scores (R(2) < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users.

  17. The relation of functional visual acuity measurement methodology to tear functions and ocular surface status.

    PubMed

    Kaido, Minako; Ishida, Reiko; Dogru, Murat; Tsubota, Kazuo

    2011-09-01

    To investigate the relation of functional visual acuity (FVA) measurements with dry eye test parameters and to compare the testing methods with and without blink suppression and anesthetic instillation. A prospective comparative case series. Thirty right eyes of 30 dry eye patients and 25 right eyes of 25 normal subjects seen at Keio University School of Medicine, Department of Ophthalmology were studied. FVA testing was performed using a FVA measurement system with two different approaches, one in which measurements were made under natural blinking conditions without topical anesthesia (FVA-N) and the other in which the measurements were made under the blink suppression condition with topical anesthetic eye drops (FVA-BS). Tear function examinations, such as the Schirmer test, tear film break-up time, and fluorescein and Rose Bengal vital staining as ocular surface evaluation, were performed. The mean logMAR FVA-N scores and logMAR Landolt visual acuity scores were significantly lower in the dry eye subjects than in the healthy controls (p < 0.05), while there were no statistical differences between the logMAR FVA-BS scores of the dry eye subjects and those of the healthy controls. There was a significant correlation between the logMAR Landolt visual acuities and the logMAR FVA-N and logMAR FVA-BS scores. The FVA-N scores correlated significantly with tear quantities, tear stability and, especially, the ocular surface vital staining scores. FVA measurements performed under natural blinking significantly reflected the tear functions and ocular surface status of the eye and would appear to be a reliable method of FVA testing. FVA measurement is also an accurate predictor of dry eye status.

  18. 77 FR 61610 - Interagency Coordinating Committee on the Validation of Alternative Methods Evaluation Report and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-10

    ... Chemical Eye Hazards With Fewer Animals; Availability of Report; Notice of Transmittal to Federal Agencies... (ICCVAM) test method evaluation report (TMER) that provides recommendations for identifying chemical eye... animals in a three-animal test to identify chemicals and products that are eye hazards will maintain...

  19. Magnifying visual target information and the role of eye movements in motor sequence learning.

    PubMed

    Massing, Matthias; Blandin, Yannick; Panzer, Stefan

    2016-01-01

    An experiment investigated the influence of eye movements on learning a simple motor sequence task when the visual display was magnified. The task was to reproduce a 1300 ms spatial-temporal pattern of elbow flexions and extensions. The spatial-temporal pattern was displayed in front of the participants. Participants were randomly assigned to four groups differing on eye movements (free to use their eyes/instructed to fixate) and the visual display (small/magnified). All participants had to perform a pre-test, an acquisition phase, a delayed retention test, and a transfer test. The results indicated that participants in each practice condition increased their performance during acquisition. The participants who were permitted to use their eyes in the magnified visual display outperformed those who were instructed to fixate on the magnified visual display. When a small visual display was used, the instruction to fixate induced no performance decrements compared to participants who were permitted to use their eyes during acquisition. The findings demonstrated that a spatial-temporal pattern can be learned without eye movements, but being permitting to use eye movements facilitates the response production when the visual angle is increased. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. The effect of image sharpness on quantitative eye movement data and on image quality evaluation while viewing natural images

    NASA Astrophysics Data System (ADS)

    Vuori, Tero; Olkkonen, Maria

    2006-01-01

    The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.

  1. Eye Dominance Predicts fMRI Signals in Human Retinotopic Cortex

    PubMed Central

    Mendola, Janine D.; Conner, Ian P.

    2009-01-01

    There have been many attempts to define eye dominance in normal subjects, but limited consensus exists, and relevant physiological data is scarce. In this study, we consider two different behavioral methods for assignment of eye dominance, and how well they predict fMRI signals evoked by monocular stimulation. Sighting eye dominance was assessed with two standard tests, the Porta Test, and a ‘hole in hand’ variation of the Miles Test. Acuity dominance was tested with a standard eye chart and with a computerized test of grating acuity. We found limited agreement between the sighting and acuity methods for assigning dominance in our individual subjects. We then compared the fMRI response generated by dominant eye stimulation to that generated by non-dominant eye, according to both methods, in 7 normal subjects. The stimulus consisted of a high contrast hemifield stimulus alternating with no stimulus in a blocked paradigm. In separate scans, we used standard techniques to label the borders of visual areas V1, V2, V3, VP, V4, V3A, and MT. These regions of interest (ROIs) were used to analyze each visual area separately. We found that percent change in fMRI BOLD signal was stronger for the dominant eye as defined by the acuity method, and this effect was significant for areas located in the ventral occipital territory (V1v, V2v, VP, V4). In contrast, assigning dominance based on sighting produced no significant interocular BOLD differences. We conclude that interocular BOLD differences in normal subjects exist, and may be predicted by acuity measures. PMID:17194544

  2. Double silicone tube intubation for the management of partial lacrimal system obstruction.

    PubMed

    Demirci, Hakan; Elner, Victor M

    2008-02-01

    To evaluate the effectiveness of double silicone intubation for the management of partial lacrimal drainage system obstruction in adults. Observational retrospective case series. Twenty-four eyes of 18 consecutive adult patients with partial lacrimal system obstruction managed at the University of Michigan. Retrospective review of symptoms and signs, duration of silicone intubation, and complications. Resolution of tearing. Preoperative tearing, negative Jones I testing, positive Jones II testing, and resistance to positive-pressure irrigation were present in all eyes (100%). The first silicone tube was removed after a mean of 11+/-7 months, and the second tube after 16+/-6 months. Postoperatively, at a mean of 21+/-9 months after removal of both tubes, tearing remained resolved in 19 eyes (79%) and remained improved in 2 eyes (8%). In eyes with resolved tearing, Jones I testing became positive, and there was no resistance to positive-pressure irrigation. Persistent tearing in 3 eyes (13%) required treatment with external dacryocystorhinostomy. The only complication was peripunctal pyogenic granulomas in 2 eyes. Double silicone intubation is an effective minimally invasive technique for treatment of partial lacrimal system obstruction in adults.

  3. The identification and classification of skin irritation hazard by a human patch test.

    PubMed

    Basketter, D A; Whittle, E; Griffiths, H A; York, M

    1994-08-01

    There exist various regulatory instruments the purpose of which is to ensure that the intrinsic toxic hazards associated with substances and preparations are identified. In the context of identification of skin irritation potential, the method is normally the Draize test. Guidance notes provided by the OECD and the EEC expect that corrosive substances will have been screened out by a variety of methods. Substances or preparations which cause a sufficient degree of skin irritation will be classified as skin irritants. The primary motivation behind the present work was to introduce the concept that it is possible to assess the hazard potential of a substance or preparation to produce skin irritation in a human study. In the example presented here, 20% sodium lauryl sulfate (SLS) has been chosen as the positive control. With the protocol currently devised, occluded patch treatment with 20% SLS for up to 4 hr produces an irritant response in just over half of the panel. An irritant response is taken as a clinically evident and significant increase in erythema, oedema or dryness--a minimum of a+ reaction on the ICDRG scale. At such a level of response with the positive control (both in terms of intensity and in proportion of the panel), it is then possible to judge and/or to determine statistically, whether the test material has produced a level of skin irritation which is similar to, greater, or lower than the positive control. In this way a human patch test protocol can form a fundamental component of a strategy for the replacement of animals in determination of skin irritation and corrosion potential. By use of a careful and progressive protocol and by comparison of test data against a positive control it is both possible and practical to classify substances and preparations in terms of their skin irritation potential using that endpoint in the species of concern, man.

  4. [Development of alternative to animal experiment in evaluation of skin irritation caused by alcohol-based hand rubs].

    PubMed

    Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu

    2010-08-01

    Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.

  5. Analysis of static and dynamic balance in healthy elderly practitioners of Tai Chi Chuan versus ballroom dancing

    PubMed Central

    Rahal, Miguel Antônio; Alonso, Angélica Castilho; Andrusaitis, Felix Ricardo; Rodrigues, Thuam Silva; Speciali, Danielli Souza; Greve, Júlia Maria D′Andréa; Leme, Luiz Eugênio Garcez

    2015-01-01

    OBJECTIVE: To determine whether Tai Chi Chuan or ballroom dancing promotes better performance with respect to postural balance, gait, and postural transfer among elderly people. METHODS: We evaluated 76 elderly individuals who were divided into two groups: the Tai Chi Chuan Group and the Dance Group. The subjects were tested using the NeuroCom Balance Master® force platform system with the following protocols: static balance tests (the Modified Clinical Tests of Sensory Interaction on Balance and Unilateral Stance) and dynamic balance tests (the Walk Across Test and Sit-to-stand Transfer Test). RESULTS: In the Modified Clinical Test of Sensory Interaction on Balance, the Tai Chi Chuan Group presented a lower sway velocity on a firm surface with open and closed eyes, as well as on a foam surface with closed eyes. In the Modified Clinical Test of Sensory Interaction on Unilateral Stance, the Tai Chi Chuan Group presented a lower sway velocity with open eyes, whereas the Dance Group presented a lower sway velocity with closed eyes. In the Walk Across Test, the Tai Chi Chuan Group presented faster walking speeds than those of the Dance Group. In the Sit-to-stand Transfer Test, the Tai Chi Chuan Group presented shorter transfer times from the sitting to the standing position, with less sway in the final standing position. CONCLUSION: The elderly individuals who practiced Tai Chi Chuan had better bilateral balance with eyes open on both types of surfaces compared with the Dance Group. The Dance Group had better unilateral postural balance with eyes closed. The Tai Chi Chuan Group had faster walking speeds, shorter transfer times, and better postural balance in the final standing position during the Sit-to-stand Test. PMID:26017644

  6. Analysis of static and dynamic balance in healthy elderly practitioners of Tai Chi Chuan versus ballroom dancing.

    PubMed

    Rahal, Miguel Antônio; Alonso, Angélica Castilho; Andrusaitis, Felix Ricardo; Rodrigues, Thuam Silva; Speciali, Danielli Souza; Greve, Júlia Maria D Andréa; Leme, Luiz Eugênio Garcez

    2015-03-01

    To determine whether Tai Chi Chuan or ballroom dancing promotes better performance with respect to postural balance, gait, and postural transfer among elderly people. We evaluated 76 elderly individuals who were divided into two groups: the Tai Chi Chuan Group and the Dance Group. The subjects were tested using the NeuroCom Balance Master¯ force platform system with the following protocols: static balance tests (the Modified Clinical Tests of Sensory Interaction on Balance and Unilateral Stance) and dynamic balance tests (the Walk Across Test and Sit-to-stand Transfer Test). In the Modified Clinical Test of Sensory Interaction on Balance, the Tai Chi Chuan Group presented a lower sway velocity on a firm surface with open and closed eyes, as well as on a foam surface with closed eyes. In the Modified Clinical Test of Sensory Interaction on Unilateral Stance, the Tai Chi Chuan Group presented a lower sway velocity with open eyes, whereas the Dance Group presented a lower sway velocity with closed eyes. In the Walk Across Test, the Tai Chi Chuan Group presented faster walking speeds than those of the Dance Group. In the Sit-to-stand Transfer Test, the Tai Chi Chuan Group presented shorter transfer times from the sitting to the standing position, with less sway in the final standing position. The elderly individuals who practiced Tai Chi Chuan had better bilateral balance with eyes open on both types of surfaces compared with the Dance Group. The Dance Group had better unilateral postural balance with eyes closed. The Tai Chi Chuan Group had faster walking speeds, shorter transfer times, and better postural balance in the final standing position during the Sit-to-stand Test.

  7. Retinal vein occlusion

    MedlinePlus

    ... of one eye. Exams and Tests Tests to evaluate for vein occlusion include: Exam of the retina after dilating the pupil An eye test that uses a special dye and camera to look at blood flow in the retina and choroid. Intraocular pressure Pupil ...

  8. Validity of autorefractor based screening method for irregular astigmatism compared to the corneal topography- a cross sectional study.

    PubMed

    Galindo-Ferreiro, Alicia; De Miguel-Gutierrez, Julita; González-Sagrado, Manuel; Galvez-Ruiz, Alberto; Khandekar, Rajiv; Schellini, Silvana; Galindo-Alonso, Julio

    2017-01-01

    To present a method of screening for irregular astigmatism with an autorefractor and its determinants compared to corneal topography. This cross-sectional validity study was conducted in 2013 at an eye hospital in Spain. A tabletop autorefractor (test 1) was used to measure the refractive status of the anterior surface of the cornea at two corneal meridians of each eye. Then corneal topography (test 2) and Bogan's classification was used to group eyes into those with regular or no astigmatism (GRI) and irregular astigmatism (GRII). Test 1 provided a single absolute value for the greatest cylinder difference (Vr). The receiver operating characteristic (ROC) were plotted for the Vr values measured by test 1 for GRI and GRII eyes. On the basis a Vr value of 1.25 D as cut off, sensitivity, specificity were also calculated. The study sample was comprised of 260 eyes (135 patients). The prevalence of irregular astigmatism was 42% [95% confidence interval (CI): 36, 48]. Based on test 2, there were 151 eyes in GRI and 109 eyes in GRII. The median Vr was 0.75 D (25% quartile, 0.5 D) for GRI and 1.75 D (25% quartile, 1.25 D) for GRII. The area under curve was 0.171 for GRI and 0.83 for GRII. The sensitivity of test I was 78.1% and the specificity was 76.1%. A conventional autorefractor can be effective as a first level screening method to detect irregular corneal astigmatism in places where corneal topography facilities are not available.

  9. Eye Movements in Implicit Artificial Grammar Learning

    ERIC Educational Resources Information Center

    Silva, Susana; Inácio, Filomena; Folia, Vasiliki; Petersson, Karl Magnus

    2017-01-01

    Artificial grammar learning (AGL) has been probed with forced-choice behavioral tests (active tests). Recent attempts to probe the outcomes of learning (implicitly acquired knowledge) with eye-movement responses (passive tests) have shown null results. However, these latter studies have not tested for sensitivity effects, for example, increased…

  10. Video-based eye tracking for neuropsychiatric assessment.

    PubMed

    Adhikari, Sam; Stark, David E

    2017-01-01

    This paper presents a video-based eye-tracking method, ideally deployed via a mobile device or laptop-based webcam, as a tool for measuring brain function. Eye movements and pupillary motility are tightly regulated by brain circuits, are subtly perturbed by many disease states, and are measurable using video-based methods. Quantitative measurement of eye movement by readily available webcams may enable early detection and diagnosis, as well as remote/serial monitoring, of neurological and neuropsychiatric disorders. We successfully extracted computational and semantic features for 14 testing sessions, comprising 42 individual video blocks and approximately 17,000 image frames generated across several days of testing. Here, we demonstrate the feasibility of collecting video-based eye-tracking data from a standard webcam in order to assess psychomotor function. Furthermore, we were able to demonstrate through systematic analysis of this data set that eye-tracking features (in particular, radial and tangential variance on a circular visual-tracking paradigm) predict performance on well-validated psychomotor tests. © 2017 New York Academy of Sciences.

  11. Corneal permeability changes in dry eye disease: an observational study.

    PubMed

    Fujitani, Kenji; Gadaria, Neha; Lee, Kyu-In; Barry, Brendan; Asbell, Penny

    2016-05-13

    Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. Dry eye patients who have had established signs or symptoms for at least 6 months were included in this observational study. Normal subjects with no symptoms of dry eyes served as controls. Each eye had a baseline fluorescein scan prior to any fluorescein dye. Fluorescein dye was then placed into both eyes, rinsed with saline solution, and scanned at 5, 10, 15, and 30 min. Patients were administered the following diagnostic tests to correlate with fluorophotometry: OSDI, TBUT, fluorescein, and lissamine. Standard protocols were used. P < 0.05 was considered significant. Fifty eyes from 25 patients (DED = 22 eyes, 11 patients; Normal = 28 eyes, 14 patients) were included. Baseline scans of the dry eye and control groups did not show any statistical difference (p = 0.84). Fluorescein concentration of DED and normal patients showed statistical significance at all time intervals (p < 10(-5), 0.001, 0.002, 0.049 for 5, 10, 15, & 30 min respectively). Fluorophotometry values converged towards baseline as time elapsed, but both groups were still statistically different at 30 min (p < 0.01). We used four fluorophotometry scoring methods and correlated them with OSDI, TBUT, fluorescein, and lissamine along with adjusted and aggregate scores. The four scoring schemes did not show any significant correlations with the other tests, except for correlations seen with lissamine and 10 (p = 0.045, 0.034) and 15 min (p = 0.013, 0.012), and with aggregate scores and 15 min (p = 0.042, 0.017). Fluorophotometry generally did not correlate with any other DED tests, even though it showed capability of differentiating between DED and normal eyes up to 30 min after fluorescein dye instillation. There may be an aspect of DED that is missed in the current regimen of DED tests and only captured with fluorophotometry. Adding fluorophotometry may be useful in screening, diagnosing, and monitoring patients with DED.

  12. Testing of visual field with virtual reality goggles in manual and visual grasp modes.

    PubMed

    Wroblewski, Dariusz; Francis, Brian A; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4-6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode.

  13. Is adaptation to perceived interocular differences in height explained by vertical fusional eye movements?

    PubMed

    Maier, Felix M; Schaeffel, Frank

    2013-07-24

    To find out whether adaptation to a vertical prism involves more than fusional vertical eye movements. Adaptation to a vertical base-up 3 prism diopter prism was measured in a custom-programmed Maddox test in nine visually normal emmetropic subjects (mean age 27.0 ± 2.8 years). Vertical eye movements were binocularly measured in six of the subjects with a custom-programmed binocular video eye tracker. In the Maddox test, some subjects adjusted the perceived height as expected from the power of the prism while others appeared to ignore the prism. After 15 minutes of adaptation, the interocular difference in perceived height was reduced by on average 51% (from 0.86°-0.44°). The larger the initially perceived difference in height in a subject, the larger the amplitude of adaptation was. Eye tracking showed that the prism generated divergent vertical eye movements of 1.2° on average, which was less than expected from its power. Differences in eye elevation were maintained as long as the prism was in place. Small angles of lateral head tilt generated large interocular differences in eye elevation, much larger than the effects introduced by the prism. Vertical differences in retinal image height were compensated by vertical fusional eye movements but some subjects responded poorly to a vertical prism in both experiments; fusional eye movements were generally too small to realign both foveae with the fixation target; and the prism adaptation in the Maddox test was fully explained by the changes in vertical eye position, suggesting that no further adaptational mechanism may be involved.

  14. Walking with eyes closed is easier than walking with eyes open without visual cues: The Romberg task versus the goggle task.

    PubMed

    Yelnik, A P; Tasseel Ponche, S; Andriantsifanetra, C; Provost, C; Calvalido, A; Rougier, P

    2015-12-01

    The Romberg test, with the subject standing and with eyes closed, gives diagnostic arguments for a proprioceptive disorder. Closing the eyes is also used in balance rehabilitation as a main way to stimulate neural plasticity with proprioceptive, vestibular and even cerebellar disorders. Nevertheless, standing and walking with eyes closed or with eyes open in the dark are certainly 2 different tasks. We aimed to compare walking with eyes open, closed and wearing black or white goggles in healthy subjects. A total of 50 healthy participants were randomly divided into 2 protocols and asked to walk on a 5-m pressure-sensitive mat, under 3 conditions: (1) eyes open (EO), eyes closed (EC) and eyes open with black goggles (BG) and (2) EO, EO with BG and with white goggles (WG). Gait was described by velocity (m·s(-1)), double support (% gait cycle), gait variability index (GVI/100) and exit from the mat (%). Analysis involved repeated measures Anova, Holm-Sidak's multiple comparisons test for parametric parameters (GVI) and Dunn's multiple comparisons test for non-parametric parameters. As compared with walking with EC, walking with BG produced lower median velocity, by 6% (EO 1.26; BG 1.01 vs EC 1.07 m·s(-1), P=0.0328), and lower mean GVI, by 8% (EO 91.8; BG 66.8 vs EC 72.24, P=0.009). Parameters did not differ between walking under the BG and WG conditions. The goggle task increases the difficulty in walking with visual deprivation compared to the Romberg task, so the goggle task can be proposed to gradually increase the difficulty in walking with visual deprivation (from eyes closed to eyes open in black goggles). Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Glaucoma management in patients with osteo-odonto-keratoprosthesis (OOKP): the Singapore OOKP Study.

    PubMed

    Kumar, Rajesh S; Tan, Donald T H; Por, Yong-Ming; Oen, Francis T; Hoh, Sek-Tien; Parthasarathy, Anand; Aung, Tin

    2009-01-01

    To report diagnostic modalities and treatment options for glaucoma in eyes with osteo-odonto keratoprosthesis (OOKP). Eyes that underwent OOKP were evaluated for glaucoma at the time of the first postoperative visit, then at 1 and 3 months after the procedure, and thereafter every 6 months. All eyes underwent stereo-biomicroscopic optic nerve head (ONH) assessment, kinetic (Goldmann perimetry) and automated static visual field testing, ONH photography, Heidelberg retina tomograph, scanning laser polarimetery (GDx), and optical coherence tomography. Treatment of glaucoma was also reviewed. Average follow-up period was 19.1 (range: 5 to 31) months. Of the 15 eyes that underwent OOKP, 5 eyes had preexisting glaucoma. None of the other 10 eyes developed glaucoma after OOKP. ONH photography and visual field testing were the most reliable methods to assess status of the disease, whereas Heidelberg retina tomograph and optical coherence tomography could be performed with reasonable reproducibility and quality; GDx imaging was poor. All patients with glaucoma were treated with oral acetazolamide 500 mg twice a day. Transscleral cyclophotocoagulation was performed in 3 eyes at stage 2 of OOKP surgery. Progression of glaucoma was noted in 2 eyes on the basis of optic disc photographs and automated perimetry. Visual field testing and optic disc assessment with optic disc photographs seem to be effective methods to monitor eyes with OOKP for glaucoma. Treatment strategies include oral medications to lower intraocular pressure and cyclophotocoagulation.

  16. Vision problems

    MedlinePlus

    ... shade or curtain hanging across part of your visual field. Optic neuritis : inflammation of the optic nerve ... to ask your doctor Images Crossed eyes Eye Visual acuity test Slit-lamp exam Visual field test ...

  17. Visual function assessment in simulated real-life situations in patients with age-related macular degeneration compared to normal subjects.

    PubMed

    Barteselli, G; Gomez, M L; Doede, A L; Chhablani, J; Gutstein, W; Bartsch, D-U; Dustin, L; Azen, S P; Freeman, W R

    2014-10-01

    To evaluate visual function variations in eyes with age-related macular degeneration (AMD) compared to normal eyes under different light/contrast conditions using a time-dependent visual acuity testing instrument, the Central Vision Analyzer (CVA). Overall, 37 AMD eyes and 35 normal eyes were consecutively tested with the CVA after assessing best-corrected visual acuity (BCVA) using ETDRS charts. The CVA established visual thresholds for three mesopic environments (M1 (high contrast), M2 (medium contrast), and M3 (low contrast)) and three backlight-glare environments (G1 (high contrast, equivalent to ETDRS), G2 (medium contrast), and G3 (low contrast)) under timed conditions. Vision drop across environments was calculated, and repeatability of visual scores was determined. BCVA significantly reduced with decreasing contrast in all eyes. M1 scores for BCVA were greater than M2 and M3 (P<0.001); G1 scores were greater than G2 and G3 (P<0.01). BCVA dropped more in AMD eyes than in normal eyes between M1 and M2 (P=0.002) and between M1 and M3 (P=0.003). In AMD eyes, BCVA was better using ETDRS charts compared to G1 (P<0.001). The drop in visual function between ETDRS and G1 was greater in AMD eyes compared to normal eyes (P=0.004). Standard deviations of test-retest ranged from 0.100 to 0.139 logMAR. The CVA allowed analysis of the visual complaints that AMD patients experience with different lighting/contrast time-dependent conditions. BCVA changed significantly under different lighting/contrast conditions in all eyes, however, AMD eyes were more affected by contrast reduction than normal eyes. In AMD eyes, timed conditions using the CVA led to worse BCVA compared to non-timed ETDRS charts.

  18. Effects of bilateral eye movements on the retrieval of item, associative, and contextual information.

    PubMed

    Parker, Andrew; Relph, Sarah; Dagnall, Neil

    2008-01-01

    Two experiments are reported that investigate the effects of saccadic bilateral eye movements on the retrieval of item, associative, and contextual information. Experiment 1 compared the effects of bilateral versus vertical versus no eye movements on tests of item recognition, followed by remember-know responses and associative recognition. Supporting previous research, bilateral eye movements enhanced item recognition by increasing the hit rate and decreasing the false alarm rate. Analysis of remember-know responses indicated that eye movement effects were accompanied by increases in remember responses. The test of associative recognition found that bilateral eye movements increased correct responses to intact pairs and decreased false alarms to rearranged pairs. Experiment 2 assessed the effects of eye movements on the recall of intrinsic (color) and extrinsic (spatial location) context. Bilateral eye movements increased correct recall for both types of context. The results are discussed within the framework of dual-process models of memory and the possible neural underpinnings of these effects are considered.

  19. The utility of modeling word identification from visual input within models of eye movements in reading

    PubMed Central

    Bicknell, Klinton; Levy, Roger

    2012-01-01

    Decades of empirical work have shown that a range of eye movement phenomena in reading are sensitive to the details of the process of word identification. Despite this, major models of eye movement control in reading do not explicitly model word identification from visual input. This paper presents a argument for developing models of eye movements that do include detailed models of word identification. Specifically, we argue that insights into eye movement behavior can be gained by understanding which phenomena naturally arise from an account in which the eyes move for efficient word identification, and that one important use of such models is to test which eye movement phenomena can be understood this way. As an extended case study, we present evidence from an extension of a previous model of eye movement control in reading that does explicitly model word identification from visual input, Mr. Chips (Legge, Klitz, & Tjan, 1997), to test two proposals for the effect of using linguistic context on reading efficiency. PMID:23074362

  20. Mental Imagery as Revealed by Eye Movements and Spoken Predicates: A Test of Neurolinguistic Programming.

    ERIC Educational Resources Information Center

    Elich, Matthew; And Others

    1985-01-01

    Tested Bandler and Grinder's proposal that eye movement direction and spoken predicates are indicative of sensory modality of imagery. Subjects reported images in the three modes, but no relation between imagery and eye movements or predicates was found. Visual images were most vivid and often reported. Most subjects rated themselves as visual,…

  1. Eye-movements and ongoing task processing.

    PubMed

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  2. [Solar retinopathy].

    PubMed

    Kawa, P; Mańkowska, A; Mackiewicz, J; Zagórski, Z

    1998-01-01

    The purpose of this study is the present clinical evaluation of 21 patients (number of affected eyes--33), who watched eclipse of the sun on 12 October 1996. All patients had general ophthalmic examination with emphasis on visual acuity, visual field, Amsler test, fluorescein angiography and fundus appearance. Eleven out of 21 patients had at least one follow up examination (number of affected eyes--17). None of the patient received any treatment. All patients revealed tiny, central scotomata--positive Amsler test and decreased visual acuity on the first visit; reading Snellen chart could be improved in all patients by adequate head tilt or eye movement (improvement up to 3 Snellen chart lines). No signs of retinopathy were observed in two eyes with uncorrected refractive error and one amblyopic eye. After 7-8 weeks the visual acuity was decreased to 5/30 in two eyes and to 5/10 in ten eyes. In all those eyes persisted a tiny, central scotoma. Looking at the eclipse of the sun in spite of using primitive eye protection may cause irreversible retinal damage. Return of visual acuity to 5/5 does not always imply complete recovery because of persistent central scotoma.

  3. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    PubMed

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P < .05) occurred between the testing sessions for any of the tests. The standard error of measurement ranged from 15.9 to 23.6%. Reliability estimates were similar between the two stances and visual conditions assessed. Slightly higher coefficients were identified for the self-selected stances compared to the narrow stances under both visual conditions; however, there were negligible differences between the sessions. The within subject session-to-session variability provides a basis for further research to consider differences between fallers and non-fallers. Reliability for eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  4. [Eyes test performance among unaffected mothers of patients with schizophrenia].

    PubMed

    Birdal, Seval; Yıldırım, Ejder Akgün; Arslan Delice, Mehtap; Yavuz, Kasım Fatih; Kurt, Erhan

    2015-01-01

    Theory of Mind (ToM) deficit is a widely accepted feature of schizophrenia. A number of studies have examined ToM deficits of first degree relatives of schizophrenic patients as genetic markers of schizophrenia. Examination of mentalization capacity among mothers of schizophrenia patients may improve our understanding of theory of mind impairments in schizophrenia. The aim of this study is to use Reading Mind in the Eyes test to examine theory of mind capacity among mothers of schizophrenic patients. Performance during the test "Reading the Mind in the Eyes" (Eyes Test) was compared between the mothers of schizophrenic patients (n=47) and mothers whose children have no psychotic mental illness (n=47). Test results were analyzed based on the categorization of test items as positive, negative, and neutral. Mothers of schizophrenic patients displayed poorer performance during the Eyes Test compare to mothers in the control group, particularly in the recognition of positive and neutral mental representations. There was no statistically significant difference in the recognition of negative mental representations between mothers of patients and the control groups. The results of this study indicate that mothers of schizophrenic patients differ in some theory of mind patterns. Theory of mind may be an important developmental or endophenotipic factor in the pathogenesis of schizophrenia and should be further evaluated using other biological markers.

  5. Your Child's Vision

    MedlinePlus

    ... 3½, kids should have eye health screenings and visual acuity tests (tests that measure sharpness of vision) ... eye rubbing extreme light sensitivity poor focusing poor visual tracking (following an object) abnormal alignment or movement ...

  6. Relationship Between Eye Movement and Cognitive Information Acquisition Utilizing an Unobtrusive Eye Movement Monitoring Device.

    ERIC Educational Resources Information Center

    Nesbit, Larry L.

    A research study was designed to test the relationship between the number of eye fixations and amount of learning as determined by a criterion referenced posttest. The study sought to answer the following questions: (1) Are differences in eye movement indices related to the posttest score? (2) Do differences in eye movement indices of subjects…

  7. Investigating the Construct Measured by Banked Gap-Fill Items: Evidence from Eye-Tracking

    ERIC Educational Resources Information Center

    McCray, Gareth; Brunfaut, Tineke

    2018-01-01

    This study investigates test-takers' processing while completing banked gap-fill tasks, designed to test reading proficiency, in order to test theoretically based expectations about the variation in cognitive processes of test-takers across levels of performance. Twenty-eight test-takers' eye traces on 24 banked gap-fill items (on six tasks) were…

  8. Human corneal epithelial cell shedding and fluorescein staining in response to silicone hydrogel lenses and contact lens disinfecting solutions.

    PubMed

    Gorbet, Maud; Peterson, Rachael; McCanna, David; Woods, Craig; Jones, Lyndon; Fonn, Desmond

    2014-03-01

    A pilot study was conducted to evaluate human corneal epithelial cell shedding in response to wearing a silicone hydrogel contact lens/solution combination inducing corneal staining. The nature of ex vivo collected cells staining with fluorescein was also examined. A contralateral eye study was conducted in which up to eight participants were unilaterally exposed to a multipurpose contact lens solution/silicone hydrogel lens combination previously shown to induce corneal staining (renu® fresh™ and balafilcon A; test eye), with the other eye using a combination of balafilcon A soaked in a hydrogen peroxide care system (Clear Care®; control eye). Lenses were worn for 2, 4 or 6 hours. Corneal staining was graded after lens removal. The Ocular Surface Cell Collection Apparatus was used to collect cells from the cornea and the contact lens. In the test eye, maximum solution-induced corneal staining (SICS) was observed after 2 hours of lens wear (reducing significantly by 4 hours; p < 0.001). There were significantly more cells collected from the test eye after 4 hours of lens wear when compared to the control eye and the collection from the test eye after 2 hours (for both; n = 5; p < 0.001). The total cell yield at 4 hours was 813 ± 333 and 455 ± 218 for the test and control eyes, respectively (N = 5, triplicate, p = 0.003). A number of cells were observed to have taken up the fluorescein dye from the initial fluorescein instillation. Confocal microscopy of fluorescein-stained cells revealed that fluorescein was present throughout the cell cytoplasm and was retained in the cells for many hours after recovery from the corneal surface. This pilot study indicates that increased epithelial cell shedding was associated with a lens-solution combination which induces SICS. Our data provides insight into the transient nature of the SICS reaction and the nature of fluorescein staining observed in SICS.

  9. Efficacy of punctal occlusion in management of dry eyes after laser in situ keratomileusis for myopia.

    PubMed

    Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah

    2014-03-01

    To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p < 0.0001; 2 months, p < 0.0001; 6 months, p = 0.008). At the final follow-up visit, the percentage of normal eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.

  10. Predator mimicry, not conspicuousness, explains the efficacy of butterfly eyespots

    PubMed Central

    De Bona, Sebastiano; Valkonen, Janne K.; López-Sepulcre, Andrés; Mappes, Johanna

    2015-01-01

    Large conspicuous eyespots on butterfly wings have been shown to deter predators. This has been traditionally explained by mimicry of vertebrate eyes, but recently the classic eye-mimicry hypothesis has been challenged. It is proposed that the conspicuousness of the eyespot, not mimicry, is what causes aversion due to sensory biases, neophobia or sensory overloads. We conducted an experiment to directly test whether the eye-mimicry or the conspicuousness hypothesis better explain eyespot efficacy. We used great tits (Parus major) as model predator, and tested their reaction towards animated images on a computer display. Birds were tested against images of butterflies without eyespots, with natural-looking eyespots, and manipulated spots with the same contrast but reduced resemblance to an eye, as well as images of predators (owls) with and without eyes. We found that mimetic eyespots were as effective as true eyes of owls and more efficient in eliciting an aversive response than modified, less mimetic but equally contrasting eyespots. We conclude that the eye-mimicry hypothesis explains our results better than the conspicuousness hypothesis and is thus likely to be an important mechanism behind the evolution of butterfly eyespots. PMID:25854889

  11. Extraocular muscle function testing

    MedlinePlus

    ... may result in double vision or rapid, uncontrolled eye movements . Normal Results Normal movement of the eyes in all directions. What Abnormal Results Mean Eye movement disorders may be due to abnormalities of the ...

  12. Crowded letter and crowded picture logMAR acuity in children with amblyopia: a quantitative comparison.

    PubMed

    O'Boyle, Cathy; Chen, Sean I; Little, Julie-Anne

    2017-04-01

    Clinically, picture acuity tests are thought to overestimate visual acuity (VA) compared with letter tests, but this has not been systematically investigated in children with amblyopia. This study compared VA measurements with the LogMAR Crowded Kay Picture test to the LogMAR Crowded Keeler Letter acuity test in a group of young children with amblyopia. 58 children (34 male) with amblyopia (22 anisometropic, 18 strabismic and 18 with both strabismic/anisometropic amblyopia) aged 4-6 years (mean=68.7, range=48-83 months) underwent VA measurements. VA chart testing order was randomised, but the amblyopic eye was tested before the fellow eye. All participants wore up-to-date refractive correction. The Kay Picture test significantly overestimated VA by 0.098 logMAR (95% limits of agreement (LOA), 0.13) in the amblyopic eye and 0.088 logMAR (95% LOA, 0.13) in the fellow eye, respectively (p<0.001). No interactions were found from occlusion therapy, refractive correction or type of amblyopia on VA results (p>0.23). For both the amblyopic and fellow eyes, Bland-Altman plots demonstrated a systematic and predictable difference between Kay Picture and Keeler Letter charts across the range of acuities tested (Keeler acuity: amblyopic eye 0.75 to -0.05 logMAR; fellow eye 0.45 to -0.15 logMAR). Linear regression analysis (p<0.00001) and also slope values close to one (amblyopic 0.98, fellow 0.86) demonstrate that there is no proportional bias. The Kay Picture test consistently overestimated VA by approximately 0.10 logMAR when compared with the Keeler Letter test in young children with amblyopia. Due to the predictable difference found between both crowded logMAR acuity tests, it is reasonable to adjust Kay Picture acuity thresholds by +0.10 logMAR to compute expected Keeler Letter acuity scores. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Genotoxicity, acute oral and dermal toxicity, eye and dermal irritation and corrosion and skin sensitisation evaluation of silver nanoparticles.

    PubMed

    Kim, Jin Sik; Song, Kyung Seuk; Sung, Jae Hyuck; Ryu, Hyun Ryol; Choi, Byung Gil; Cho, Hyun Sun; Lee, Jin Kyu; Yu, Il Je

    2013-08-01

    To clarify the health risks related to silver nanoparticles (Ag-NPs), we evaluated the genotoxicity, acute oral and dermal toxicity, eye irritation, dermal irritation and corrosion and skin sensitisation of commercially manufactured Ag-NPs according to the OECD test guidelines and GLP. The Ag-NPs were not found to induce genotoxicity in a bacterial reverse mutation test and chromosomal aberration test, although some cytotoxicity was observed. In acute oral and dermal toxicity tests using rats, none of the rats showed any abnormal signs or mortality at a dose level of ∼ 2000 mg/kg. Similarly, acute eye and dermal irritation and corrosion tests using rabbits revealed no significant clinical signs or mortality and no acute irritation or corrosion reaction for the eyes and skin. In a skin sensitisation test using guinea pigs, one animal (1/20) showed discrete or patchy erythema, thus Ag-NPs can be classified as a weak skin sensitiser.

  14. Automated classifiers for early detection and diagnosis of retinopathy in diabetic eyes.

    PubMed

    Somfai, Gábor Márk; Tátrai, Erika; Laurik, Lenke; Varga, Boglárka; Ölvedy, Veronika; Jiang, Hong; Wang, Jianhua; Smiddy, William E; Somogyi, Anikó; DeBuc, Delia Cabrera

    2014-04-12

    Artificial neural networks (ANNs) have been used to classify eye diseases, such as diabetic retinopathy (DR) and glaucoma. DR is the leading cause of blindness in working-age adults in the developed world. The implementation of DR diagnostic routines could be feasibly improved by the integration of structural and optical property test measurements of the retinal structure that provide important and complementary information for reaching a diagnosis. In this study, we evaluate the capability of several structural and optical features (thickness, total reflectance and fractal dimension) of various intraretinal layers extracted from optical coherence tomography images to train a Bayesian ANN to discriminate between healthy and diabetic eyes with and with no mild retinopathy. When exploring the probability as to whether the subject's eye was healthy (diagnostic condition, Test 1), we found that the structural and optical property features of the outer plexiform layer (OPL) and the complex formed by the ganglion cell and inner plexiform layers (GCL + IPL) provided the highest probability (positive predictive value (PPV) of 91% and 89%, respectively) for the proportion of patients with positive test results (healthy condition) who were correctly diagnosed (Test 1). The true negative, TP and PPV values remained stable despite the different sizes of training data sets (Test 2). The sensitivity, specificity and PPV were greater or close to 0.70 for the retinal nerve fiber layer's features, photoreceptor outer segments and retinal pigment epithelium when 23 diabetic eyes with mild retinopathy were mixed with 38 diabetic eyes with no retinopathy (Test 3). A Bayesian ANN trained on structural and optical features from optical coherence tomography data can successfully discriminate between healthy and diabetic eyes with and with no retinopathy. The fractal dimension of the OPL and the GCL + IPL complex predicted by the Bayesian radial basis function network provides better diagnostic utility to classify diabetic eyes with mild retinopathy. Moreover, the thickness and fractal dimension parameters of the retinal nerve fiber layer, photoreceptor outer segments and retinal pigment epithelium show promise for the diagnostic classification between diabetic eyes with and with no mild retinopathy.

  15. Proprioceptive role for palisade endings in extraocular muscles: evidence from the Jendrassik Maneuver.

    PubMed

    Niechwiej-Szwedo, E; González, E; Bega, S; Verrier, M C; Wong, A M; Steinbach, M J

    2006-07-01

    A proprioceptive hypothesis for the control of eye movements has been recently proposed based on neuroanatomical tracing studies. It has been suggested that the non-twitch motoneurons could be involved in modulating the gain of sensory feedback from the eye muscles analogous to the gamma (gamma) motoneurons which control the gain of proprioceptive feedback in skeletal muscles. We conducted behavioral and psychophysical experiments to test the above hypothesis using the Jendrassik Maneuver (JM) to alter the activity of gamma motoneurons. It was hypothesized that the JM would alter the proprioceptive feedback from the eye muscles which would result in misregistration of eye position and mislocalization of targets. In the first experiment, vergence eye movements and pointing responses were examined. Data showed that the JM affected the localization responses but not the actual eye position. Perceptual judgments were tested in the second experiment, and the results showed that targets were perceived as farther when the afferent feedback was altered by the JM. Overall, the results from the two experiments showed that eye position was perceived as more divergent with the JM, but the actual eye movements were not affected. We tested this further in Experiment 3 by examining the effect of JM on the amplitude and velocity of saccadic eye movements. As expected, there were no significant differences in saccadic parameters between the control and experimental conditions. Overall, the present study provides novel insight into the mechanism which may be involved in the use of sensory feedback from the eye muscles. Data from the first two experiments support the hypothesis that the JM alters the registered eye position, as evidenced by the localization errors. We propose that the altered eye position signal is due to the effect of the JM which changes the gain of the sensory feedback from the eye muscles, possibly via the activity of non-twitch motoneurons.

  16. Albinism

    MedlinePlus

    ... normal skin and hair Patches of missing skin color Many forms of albinism are associated with the following symptoms: Crossed eyes Light sensitivity Rapid eye movements Vision problems, or functional blindness Exams and Tests Genetic testing offers the most ...

  17. The Evaluation of Anatomic and Functional Changes in Unilateral Moderate Amblyopic Eyes Using Optical Coherence Tomography and Pupil Cycle Time.

    PubMed

    Kusbeci, Tuncay; Karti, Omer; Karahan, Eyyup; Oguztoreli, Mustafa

    2017-12-01

    To investigate whether macular anatomic structure and afferent visual system function differ among amblyopic eyes, non-amblyopic fellow eyes, and controls, using spectral-domain optical coherence tomography (SD-OCT), and pupil cycle time (PCT). This observational, cross-sectional study included 30 patients with unilateral amblyopia and 30 healthy subjects. Optical coherence tomography (OCT) and pupil cycle time (PCT) were used to evaluate patients with unilateral amblyopia and were compared with their non-amblyopic fellow eyes and age- and gender-matched healthy eyes (30 participants). The amblyopic eyes were separated into two groups: anisometropic amblyopia (n = 16) and strabismic amblyopia (n = 14). OCT maps were used to calculate central macular thickness (CMT), retinal nerve fiber layer thickness (RNFLT), and ganglion cell-inner plexiform layer (GC-IPL) thickness. The average RNFLT, GC-IPL thickness, and CMT did not show any significant differences among the amblyopic eyes, non-amblyopic fellow eyes and controls (p > 0.05, Kruskal-Wallis test). Mean PCT was 773.57 ± 64 msn in strabismic eyes, 771.25 ± 58 msn in anisometropic eyes, 778.00 ± 72 msn in non-amblyopic fellow eyes, and 774.75 ± 69 msn in control eyes. The differences among the amblyopic eyes, its fellow and control eyes were not statistically significant (p > 0.05, Kruskal-Wallis test). In this study, we investigated morphological and functional differences among amblyopic eyes, non-amblyopic fellow eyes and controls by using SD-OCT and PCT. We did not find anatomical or functional changes in amblyopic eyes.

  18. A reliable unipedal stance test for the assessment of balance using a force platform.

    PubMed

    Ponce-González, J G; Sanchis-Moysi, J; González-Henriquez, J J; Arteaga-Ortiz, R; Calbet, J A L; Dorado, C

    2014-02-01

    The aim was to develop a unipedal stance test for the assessment of balance using a force platform. A single-leg balance test was conducted in 23 students (mean ± SD) age: 23 ± 3 years) in a standard position limiting the movement of the arms and non-supporting leg. Six attempts, with both the jumping (JL) and the contralateral leg (CL), were performed under 3 conditions: 1) eyes opened; 2) eyes closed; 3) eyes opened and executing a precision task. The same protocol was repeated two-week apart. The mean and the best result of the six attempts performed each day were taken as representative of balance. The speed of the centre of pressure (CP-Speed) showed excellent reliability for the "best result" analysis in all tests (ICCs 0.87-0.97), except in the test with the eyes closed performed on the CL (ICC<0.4). The CP-Speed had better reliability with the "best result" than with the "mean result" analysis (P<0.05), whilst no significant differences were observed between the JL and the CL (P=0.71 and P=0.96 for mean and best results analysis, respectively). A lower dispersion in the Bland and Altman graph was observed with the eyes opened than closed, and the dynamic test. The single-leg stance balance test proposed is a reliable method to assess balance, especially when performed in a static position, with the eyes opened and using the best result of six attempts as reference, independently of the stance leg.

  19. The evolution of vertebrate eye size across an environmental gradient: phenotype does not predict genotype in a Trinidadian killifish.

    PubMed

    Beston, Shannon M; Wostl, Elijah; Walsh, Matthew R

    2017-08-01

    Vertebrates exhibit substantial variation in eye size. Eye size correlates positively with visual capacity and behaviors that enhance fitness, such as predator avoidance. This foreshadows a connection between predation and eye size evolution. Yet, the conditions that favor evolutionary shifts in eye size, besides the well-known role for light availability, are unclear. We tested the influence of predation on the evolution of eye size in Trinidadian killifish, Rivulus hartii. Rivulus are located across a series of communities where they coexist with visually oriented piscivores ("high predation" sites), and no predators ("Rivulus-only" sites). Wild-caught Rivulus from high predation sites generally exhibited a smaller relative eye size than communities that lack predators. Yet, such differences were inconsistent across rivers. Second-generation common garden reared fish revealed repeatable decreases in eye size in Rivulus from high predation sites. We performed additional experiments that tested the importance of light and resources on eye size evolution. Sites that differ in light or resource availability did not differ in eye size. Our results argue that differences in predator-induced mortality underlie genetically-based shifts in vertebrate eye size. We discuss the drivers of eye size evolution in light of the nonparallel trends between the phenotypic and common garden results. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  20. Testing of Visual Field with Virtual Reality Goggles in Manual and Visual Grasp Modes

    PubMed Central

    Wroblewski, Dariusz; Francis, Brian A.; Sadun, Alfredo; Vakili, Ghazal; Chopra, Vikas

    2014-01-01

    Automated perimetry is used for the assessment of visual function in a variety of ophthalmic and neurologic diseases. We report development and clinical testing of a compact, head-mounted, and eye-tracking perimeter (VirtualEye) that provides a more comfortable test environment than the standard instrumentation. VirtualEye performs the equivalent of a full threshold 24-2 visual field in two modes: (1) manual, with patient response registered with a mouse click, and (2) visual grasp, where the eye tracker senses change in gaze direction as evidence of target acquisition. 59 patients successfully completed the test in manual mode and 40 in visual grasp mode, with 59 undergoing the standard Humphrey field analyzer (HFA) testing. Large visual field defects were reliably detected by VirtualEye. Point-by-point comparison between the results obtained with the different modalities indicates: (1) minimal systematic differences between measurements taken in visual grasp and manual modes, (2) the average standard deviation of the difference distributions of about 5 dB, and (3) a systematic shift (of 4–6 dB) to lower sensitivities for VirtualEye device, observed mostly in high dB range. The usability survey suggested patients' acceptance of the head-mounted device. The study appears to validate the concepts of a head-mounted perimeter and the visual grasp mode. PMID:25050326

  1. New testing options for diagnosing and grading dry eye disease.

    PubMed

    Foulks, Gary N; Pflugfelder, Stephen C

    2014-06-01

    To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Saccadic eye movements as a measure of residual effects: temazepam compared with other hypnotics.

    PubMed

    Hofferberth, B; Hirschberg; Grotemeyer

    1986-01-01

    Eye movements are classified into two categories: quickly running saccades and smooth pursuit movements. Saccades are fast conjugate eye movements with a preprogrammed direction, amplitude, and speed course; their purpose is to register new objects in the visual field. The duration and velocity of saccadic eye movements are very much dependent on vigilance. Comparisons were made with a number of psychometric tests [d 2 Durchstreichtest (cross out test), Viennese determination apparatus, and flicker fusion frequency] and the velocity of fast eye movements. The results of three separate investigations are presented. Standardization was undertaken in 100 healthy volunteers, 50 male and 50 female subjects aged between 20 and more than 50 years were included. In an open parallel group study, comparisons were made between various hypnotics with different half-lives (temazepam, flunitrazepam, flurazepam, and phenobarbital). There were 10 healthy volunteers in each group, and medication was taken as a single night-time dose for 7 nights. In a double-blind study, temazepam (20 mg/day) was tested against flunitrazepam (2 mg/day). Dosing lasted 7 days. A marked impairment of the saccadic eye movements was observed with flunitrazepam but not with temazepam. Of all the benzodiazepines tested, only temazepam had no influence on the parameters of the saccade test. These results can be explained by temazepam's short half-life and also by the fact that no active metabolites are formed.

  3. Aging of vestibular function evaluated using correlational vestibular autorotation test

    PubMed Central

    Hsieh, Li-Chun; Lin, Hung-Ching; Lee, Guo-She

    2014-01-01

    Background Imbalance from degeneration of vestibular end organs is a common problem in the elderly. However, the decline of vestibular function with aging was revealed in few vestibular function tests such as vestibular autorotation test (VAT). In the current VAT, there are drawbacks of poor test–retest reliability, slippage of the sensor at high-speed rotations, and limited data about the effect of aging. We developed a correlational-VAT (cVAT) system that included a small, light sensor (less than 20 g) with wireless data transmission technique to evaluate the aging of vestibular function. Material and methods We enrolled 53 healthy participants aged between 25 and 75 years and divided them into five age groups. The test conditions were vertical and horizontal head autorotations of frequencies from 0 to 3 Hz with closed eyes or open eyes. The cross-correlation coefficient (CCC) between eye velocity and head velocity was obtained for the head autorotations between 1 Hz and 3 Hz. The mean of the CCCs was used to represent the vestibular function. Results Age was significantly and negatively correlated with the mean CCC for all test conditions, including horizontal or vertical autorotations with open eyes or closed eyes (P<0.05). The mean CCC with open eyes declined significantly at 55–65 years old and the mean CCC with closed eyes declined significantly at 65–75 years old. Conclusion Vestibular function evaluated using mean CCC revealed a decline with age, and the function of visual-vestibulo-ocular reflex declined 10 years earlier than the function of vestibulo-ocular reflex. PMID:25214774

  4. Eye injury risk associated with remote control toy helicopter blades.

    PubMed

    Alphonse, Vanessa D; Kemper, Andrew R; Rowson, Steven; Duma, Stefan M

    2012-01-01

    Eye injuries can be caused by a variety of consumer products and toys. Recently, indoor remote controlled (RC) toy helicopters have become very popular. The purpose of this study is to quantify eye injury risk associated with five commercially available RC toy helicopter blades. An experimental matrix of 25 tests was developed to test five different RC toy helicopter blades at full battery power on six postmortem human eyes. A pressure sensor inserted through the optic nerve measured intraocular pressure. Corneal abrasion was assessed post-impact using fluorescein dye. Intraocular pressure was correlated to injury risk for hyphema, lens damage, retinal damage, and globe rupture using published risk functions. All tests resulted in corneal abrasions; however, no other injuries were observed. The 25 tests produced an increase intraocular pressure between 15.2 kPa and 99.3 kPa (114.3 mmHg and 744.7 mmHg). Calculated blade velocities ranged between 16.0 m/s and 25.4 m/s. Injury risk for hyphema was a maximum of 0.2%. Injury risk for lens damage, retinal damage, and globe rupture was 0.0% for all tests. Blade design parameters such as length and mass did not affect the risk of eye injury. This is the first study to quantify the risk of eye injury from RC toy helicopter blades. While corneal abrasions were observed, more serious eye injuries were neither observed nor predicted to have occurred. Results from this study are critical for establishing safe design thresholds for RC toy helicopter blades so that more serious injuries can be prevented.

  5. Dry eye in vitamin D deficiency: more than an incidental association.

    PubMed

    Yildirim, Pelin; Garip, Yeşim; Karci, Ayse Aslihan; Guler, Tuba

    2016-01-01

    The aim of this article is two-fold: (i) to demonstrate the relation between vitamin D deficiency and dry eye and impaired tear function; and (ii) to investigate the possible associations among clinical parameters of hypovitaminosis D with dry eye parameters. Fifty premenopausal women with vitamin D deficiency (serum vitamin D levels < 20 ng/mL) and 48 controls were included. Participants were assessed by Schirmer's test, tear break-up time test (TBUT), ocular surface disease index (OSDI), Stanford Health Assessment Questionnaire (HAQ), fatigue severity scale (FSS), and visual analogue scale-pain (VAS-pain). Lower scores in Schirmer's test and TBUT, and higher in OSDI were detected in patients with vitamin D deficiency than in controls (P < 0.05). FSS was negatively correlated with Schirmer's test (r = -0,29; P = 0.038) and TBUT scores (r = -0,43; P = 0.002); VAS-pain was negatively correlated with TBUT scores (r = -0.32; P = 0.023). HAQ scores showed no significant correlation with dry eye parameters (P > 0.05). Vitamin D level was negatively correlated with OSDI (r = -0.49; P < 0.001), and positively with Schirmer's test (r = 0.45; P = 0.001) and TBUT scores (r = 0.30; P = 0.029). Dry eye and impaired tear function in patients with vitamin D deficiency may indicate a protective role of vitamin D in the development of dry eye, probably by enhancing tear film parameters and reducing ocular surface inflammation. Patients with vitamin D deficiency should be evaluated for dry eye syndromes. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  6. Get Your Eyes Tested

    MedlinePlus

    ... in older adults, including: Cataracts Glaucoma Age-related macular degeneration (AMD) Diabetic eye disease Low vision Dry eye ... for glaucoma Some people who have age-related macular degeneration If you don’t have insurance, look for ...

  7. Discriminating anisometropic amblyopia from myopia based on interocular inhibition

    PubMed Central

    Jia, Wuli; Zhou, Jiawei; Lu, Zhong-Lin; Lesmes, Luis A.; Huang, Chang-Bing

    2016-01-01

    Amblyopia screening during childhood is critical for early detection and successful treatment. In the current study, we develop and evaluate a screening method that exploits the imbalanced interocular inhibition between amblyopic and fellow eyes. In nineteen subjects with anisometropic amblyopia and twenty-two age-matched subjects with myopia, we measured the area under the contrast sensitivity functions (AUCSFs) in eight monocular conditions defined by tested eye (left, right), patching of the untested eye (translucent, opaque), and refractive status (corrected, uncorrected). For each test eye, we defined the inhibition index as the ratio between AUCSF values obtained in the translucent and opaque patching conditions of the untested eye. To evaluate the screening potential of the inhibition index, we compared results from patients with amblyopia and myopia. With and without optical correction, the index was significantly lower in the amblyopic eye than in the fellow eye of the amblyopic subjects and both eyes of the myopic subjects. No significant difference was found among the two eyes of the myopic subjects and the fellow eyes of the amblyopic subjects. With the inhibition index as the predictor, a logistic regression model successfully discriminated amblyopic eyes from myopic eyes with 100% accuracy in the uncorrected condition. In the corrected condition, with the inhibition index and interocular visual acuity difference as predictors, amblyopic eyes were likewise discriminated from myopic eyes with 100% accuracy. This pattern of CSF changes, caused by the different patching modes of the untested eye, provides a potential CSF signature to discriminate anisometropic amblyopia from myopia. PMID:25701741

  8. Eye-tracking of visual attention in web-based assessment using the Force Concept Inventory

    NASA Astrophysics Data System (ADS)

    Han, Jing; Chen, Li; Fu, Zhao; Fritchman, Joseph; Bao, Lei

    2017-07-01

    This study used eye-tracking technology to investigate students’ visual attention while taking the Force Concept Inventory (FCI) in a web-based interface. Eighty nine university students were randomly selected into a pre-test group and a post-test group. Students took the 30-question FCI on a computer equipped with an eye-tracker. There were seven weeks of instruction between the pre- and post-test data collection. Students’ performance on the FCI improved significantly from pre-test to post-test. Meanwhile, the eye-tracking results reveal that the time students spent on taking the FCI test was not affected by student performance and did not change from pre-test to post-test. Analysis of students’ attention to answer choices shows that on the pre-test students primarily focused on the naïve choices and ignored the expert choices. On the post-test, although students had shifted their primary attention to the expert choices, they still kept a high level of attention to the naïve choices, indicating significant conceptual mixing and competition during problem solving. Outcomes of this study provide new insights on students’ conceptual development in learning physics.

  9. Assessing the Potential Use of Eye-Tracking Triangulation for Evaluating the Usability of an Online Diabetes Exercise System.

    PubMed

    Schaarup, Clara; Hartvigsen, Gunnar; Larsen, Lars Bo; Tan, Zheng-Hua; Årsand, Eirik; Hejlesen, Ole Kristian

    2015-01-01

    The Online Diabetes Exercise System was developed to motivate people with Type 2 diabetes to do a 25 minutes low-volume high-intensity interval training program. In a previous multi-method evaluation of the system, several usability issues were identified and corrected. Despite the thorough testing, it was unclear whether all usability problems had been identified using the multi-method evaluation. Our hypothesis was that adding the eye-tracking triangulation to the multi-method evaluation would increase the accuracy and completeness when testing the usability of the system. The study design was an Eye-tracking Triangulation; conventional eye-tracking with predefined tasks followed by The Post-Experience Eye-Tracked Protocol (PEEP). Six Areas of Interests were the basis for the PEEP-session. The eye-tracking triangulation gave objective and subjective results, which are believed to be highly relevant for designing, implementing, evaluating and optimizing systems in the field of health informatics. Future work should include testing the method on a larger and more representative group of users and apply the method on different system types.

  10. Eye-tracking-based assessment of cognitive function in low-resource settings.

    PubMed

    Forssman, Linda; Ashorn, Per; Ashorn, Ulla; Maleta, Kenneth; Matchado, Andrew; Kortekangas, Emma; Leppänen, Jukka M

    2017-04-01

    Early development of neurocognitive functions in infants can be compromised by poverty, malnutrition and lack of adequate stimulation. Optimal management of neurodevelopmental problems in infants requires assessment tools that can be used early in life, and are objective and applicable across economic, cultural and educational settings. The present study examined the feasibility of infrared eye tracking as a novel and highly automated technique for assessing visual-orienting and sequence-learning abilities as well as attention to facial expressions in young (9-month-old) infants. Techniques piloted in a high-resource laboratory setting in Finland (N=39) were subsequently field-tested in a community health centre in rural Malawi (N=40). Parents' perception of the acceptability of the method (Finland 95%, Malawi 92%) and percentages of infants completing the whole eye-tracking test (Finland 95%, Malawi 90%) were high, and percentages of valid test trials (Finland 69-85%, Malawi 68-73%) satisfactory at both sites. Test completion rates were slightly higher for eye tracking (90%) than traditional observational tests (87%) in Malawi. The predicted response pattern indicative of specific cognitive function was replicated in Malawi, but Malawian infants exhibited lower response rates and slower processing speed across tasks. High test completion rates and the replication of the predicted test patterns in a novel environment in Malawi support the feasibility of eye tracking as a technique for assessing infant development in low-resource setting. Further research is needed to the test-retest stability and predictive validity of the eye-tracking scores in low-income settings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Prevalence of Dry Eye in Uyghur and Han Ethnic Groups in Western China.

    PubMed

    Gong, Ying-Ying; Zhang, Fan; Zhou, Jin; Li, Jing; Zhang, Guang-Hui; Wang, Jun-Liang; Gu, Zhen-Sheng

    2017-06-01

    To describe and compare the prevalence and characteristics of dry eye among Han and Uyghur persons living in Kashi, the most inland city of China. A total of 1015 residents of Kashi participated in this 2013 cross-sectional study. To evaluate clinical characteristics, each subject completed (1) a dry-eye questionnaire detailing symptoms of dry eye, (2) Schirmer's I-test (SIT), (3) tear-film break-up time (BUT) test, and fluorescein staining of the cornea. Dry eye was defined as the existence of dry eye symptoms and at least two positive clinical signs. Data were analyzed using SPSS software. The prevalence and risk factors of dry eye were evaluated using a multivariate model. Overall, 282 (27.8%) of the 1015 participants were diagnosed with dry eye (95% confidence interval (CI): range, 25.5-30.1). The prevalence of dry eye among Han persons (37.9 %) (95% CI: range, 35.8-40.0) was higher than that among Uyghurs (21.8%) (95% CI: 19.6-24.0) (p < 0.05). The prevalence of dry eye was 25.6% (95% CI: range, 23.3-27.8) among men and 28.7% (95% CI: 26.5-30.9) among women (p > 0.05). Risk factors for dry eye included ethnicity, age, occupation, arthritis, and dry mouth. Our study revealed a higher prevalence of dry eye among Han than Uyghur persons in Kashi. Dry eye was significantly associated with environment and ethnicity.

  12. Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.

    PubMed

    Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang

    2015-03-01

    IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P < 0.01). In addition, IL-21 gene expression in the conjunctiva was also higher in primary SS dry eyes than in non-SS dry eyes and normal controls (P < 0.01). However, there were no significant differences in IL-21 expression in tears and the conjunctiva between non-SS dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P < 0.01) and Schirmer I test values (r = -0.23, P < 0.05) in primary SS dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.

  13. Influence of vision on masticatory muscles function: surface electromyographic evaluation

    PubMed Central

    Ciavarella, Domenico; Palazzo, Antonio; De Lillo, Alfredo; Lo Russo, Lucio; Paduano, Sergio; Laino, Luigi; Chimenti, Claudio; Frezza, Federica; Lo Muzio, Lorenzo

    2014-01-01

    Summary The role of the ocular disorders (OD) in pathogenesis of MMp is still a controversal issue. Ocular arc reflexes (OAR) may involve changes in head and neck posture and generate modifications of contraction resulting in muscle contraction and finally weakness. sEMG tests were performed on 28 patients (13 with masticatory muscles pain and myopia/15 healthy) in rest position with eyes open and eyes closed. Patients group control (healthy patients) showed no significance difference in sEMG record in open/close test. In non healthy patients there were great differences between the sEMG recordings with eyes closed and open. Temporalis and masseters showed a statistical difference of means activation in two tests (temporalis p = 0.0010; masseters = 0.0006). Great difference there was in means muscles activation between open eyes healthy test and non healthy. No difference in close eyes test was evaluated in temporalis and masseters close test in the two groups. The exact causes of MMp are still unknown. The role how ocular disorders (OD) may play an important role in pathogenesis of MMp is still a controversal issue. Ocular arc reflexes (OAR) may involve changes in head and neck posture and generate modifications of contraction resulting in muscle contraction and finally weakness. PMID:25002919

  14. The Importance of Conditional Probability in Diagnostic Reasoning and Clinical Decision Making: A Primer for the Eye Care Practitioner.

    PubMed

    Sanfilippo, Paul G; Hewitt, Alex W; Mackey, David A

    2017-04-01

    To outline and detail the importance of conditional probability in clinical decision making and discuss the various diagnostic measures eye care practitioners should be aware of in order to improve the scope of their clinical practice. We conducted a review of the importance of conditional probability in diagnostic testing for the eye care practitioner. Eye care practitioners use diagnostic tests on a daily basis to assist in clinical decision making and optimizing patient care and management. These tests provide probabilistic information that can enable the clinician to increase (or decrease) their level of certainty about the presence of a particular condition. While an understanding of the characteristics of diagnostic tests are essential to facilitate proper interpretation of test results and disease risk, many practitioners either confuse or misinterpret these measures. In the interests of their patients, practitioners should be aware of the basic concepts associated with diagnostic testing and the simple mathematical rule that underpins them. Importantly, the practitioner needs to recognize that the prevalence of a disease in the population greatly determines the clinical value of a diagnostic test.

  15. THE RELATIONSHIP BETWEEN VARIOUS MODES OF SINGLE LEG POSTURAL CONTROL ASSESSMENT

    PubMed Central

    Schmitz, Randy

    2012-01-01

    Purpose/Background: While various techniques have been developed to assess the postural control system, little is known about the relationship between single leg static and functional balance. The purpose of the current study was to determine the relationship between the performance measures of several single leg postural stability tests. Methods: Forty six recreationally active college students (17 males, 29 females, 21±3 yrs, 173±10 cm) performed six single leg tests in a counterbalanced order: 1) Firm Surface-Eyes Open, 2) Firm Surface-Eyes Closed, 3) Multiaxial Surface-Eyes Open, 4) Multiaxial Surface-Eyes Closed, 5) Star Excursion Balance Test (posterior medial reach), 6) Single leg Hop-Stabilization Test. Bivariate correlations were conducted between the six outcome variables. Results: Mild to moderate correlations existed between the static tests. No significant correlations existed involving either of the functional tests. Conclusions: The results indicate that while performance of static balance tasks are mildly to moderately related, they appear to be unrelated to functional reaching or hopping movements, supporting the utilization of a battery of tests to determine overall postural control performance. Level of Evidence: 3b PMID:22666640

  16. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  17. VARIABILITY OF VISUAL FIELD MEASUREMENTS IS CORRELATED WITH THE GRADIENT OF VISUAL SENSITIVITY

    PubMed Central

    Wyatt, Harry J.; Dul, Mitchell W.; Swanson, William H.

    2007-01-01

    Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, the rate at which sensitivity changes with location. We tested one eye each, twice within 3 weeks, of 29 patients with glaucoma, 17 young normal subjects and 13 older normal subjects. The 10-2 test pattern with the SITA Standard algorithm was used to assess sensitivity at locations with 2° spacing. Variability and gradient were calculated at individual test locations. Matrix correlations were determined between variability and gradient, and were substantial for the patients with glaucoma. The results were consistent with a substantial contribution to test-retest variability from small fixational eye movements interacting with visual field gradient. Successful characterization of the gradient of sensitivity appears to require sampling at relatively close spacing, as in the 10-2 test pattern. PMID:17320924

  18. Variability of visual field measurements is correlated with the gradient of visual sensitivity.

    PubMed

    Wyatt, Harry J; Dul, Mitchell W; Swanson, William H

    2007-03-01

    Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, the rate at which sensitivity changes with location. We tested one eye each, twice within 3 weeks, of 29 patients with glaucoma, 17 young normal subjects and 13 older normal subjects. The 10-2 test pattern with the SITA Standard algorithm was used to assess sensitivity at locations with 2 degrees spacing. Variability and gradient were calculated at individual test locations. Matrix correlations were determined between variability and gradient, and were substantial for the patients with glaucoma. The results were consistent with a substantial contribution to test-retest variability from small fixational eye movements interacting with visual field gradient. Successful characterization of the gradient of sensitivity appears to require sampling at relatively close spacing, as in the 10-2 test pattern.

  19. Making the diagnosis of Sjögren's syndrome in patients with dry eye.

    PubMed

    Beckman, Kenneth A; Luchs, Jodi; Milner, Mark S

    2016-01-01

    Sjögren's syndrome (SS) is a chronic and progressive systemic autoimmune disease that often presents initially with symptoms of dry eye and dry mouth. Symptoms are often nonspecific and develop gradually, making diagnosis difficult. Patients with dry eye complaints warrant a step-wise evaluation for possible SS. Initial evaluation requires establishment of a dry eye diagnosis using a combination of patient questionnaires and objective ocular tests, including inflammatory biomarker testing. Additional work-up using the Schirmer test and tear film break-up time can differentiate between aqueous-deficient dry eye (ADDE) and evaporative dry eye. The presence of ADDE should trigger further work-up to differentiate between SS-ADDE and non-SS-ADDE. There are numerous non-ocular manifestations of SS, and monitoring for SS-related comorbid findings can aid in diagnosis, ideally in collaboration with a rheumatologist. The clinical work-up of SS can involve a variety of tests, including tear function tests, serological tests for autoantibody biomarkers, minor salivary gland and lacrimal gland biopsies. Examination of classic SS biomarkers (SS-A/Ro, SS-B/La, antinuclear antibody, and rheumatoid factor) is a convenient and non-invasive way of evaluating patients for the presence of SS, even years prior to confirmed diagnosis, although not all SS patients will test positive, particularly those with early disease. Recently, newer biomarkers have been identified, including autoantibodies to salivary gland protein-1, parotid secretory protein, and carbonic anhydrase VI, and may allow for earlier diagnosis of SS. A diagnostic test kit is commercially available (Sjö(®)), incorporating these new biomarkers along with the classic autoantibodies. This advanced test has been shown to identify SS patients who previously tested negative against traditional biomarkers only. All patients with clinically significant ADDE should be considered for serological assessment for SS, given the availability of new serological diagnostic tests and the potentially serious consequences of missing the diagnosis.

  20. Making the diagnosis of Sjögren’s syndrome in patients with dry eye

    PubMed Central

    Beckman, Kenneth A; Luchs, Jodi; Milner, Mark S

    2016-01-01

    Sjögren’s syndrome (SS) is a chronic and progressive systemic autoimmune disease that often presents initially with symptoms of dry eye and dry mouth. Symptoms are often nonspecific and develop gradually, making diagnosis difficult. Patients with dry eye complaints warrant a step-wise evaluation for possible SS. Initial evaluation requires establishment of a dry eye diagnosis using a combination of patient questionnaires and objective ocular tests, including inflammatory biomarker testing. Additional work-up using the Schirmer test and tear film break-up time can differentiate between aqueous-deficient dry eye (ADDE) and evaporative dry eye. The presence of ADDE should trigger further work-up to differentiate between SS-ADDE and non-SS-ADDE. There are numerous non-ocular manifestations of SS, and monitoring for SS-related comorbid findings can aid in diagnosis, ideally in collaboration with a rheumatologist. The clinical work-up of SS can involve a variety of tests, including tear function tests, serological tests for autoantibody biomarkers, minor salivary gland and lacrimal gland biopsies. Examination of classic SS biomarkers (SS-A/Ro, SS-B/La, antinuclear antibody, and rheumatoid factor) is a convenient and non-invasive way of evaluating patients for the presence of SS, even years prior to confirmed diagnosis, although not all SS patients will test positive, particularly those with early disease. Recently, newer biomarkers have been identified, including autoantibodies to salivary gland protein-1, parotid secretory protein, and carbonic anhydrase VI, and may allow for earlier diagnosis of SS. A diagnostic test kit is commercially available (Sjö®), incorporating these new biomarkers along with the classic autoantibodies. This advanced test has been shown to identify SS patients who previously tested negative against traditional biomarkers only. All patients with clinically significant ADDE should be considered for serological assessment for SS, given the availability of new serological diagnostic tests and the potentially serious consequences of missing the diagnosis. PMID:26766898

  1. CON4EI: CONsortium for in vitro Eye Irritation testing strategy - EpiOcular™ time-to-toxicity (EpiOcular ET-50) protocols for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, Helena; Letasiova, Silvia; Adriaens, Els; Guest, Robert; Willoughby, Jamin A; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment for all drivers of classification. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different alternative methods. Here, the results obtained with reconstructed human cornea-like epithelium (RhCE) EpiOcular™ in the EpiOcular time-to-toxicity Tests (Neat and Dilution ET-50 protocols) are presented. The primary aim of this study was to evaluate whether test methods can discriminate chemicals not requiring classification for serious eye damage/eye irritancy (No Category) from chemicals requiring classification and labelling for Category 1 and Category 2. In addition, the predictive capacity in terms of in vivo drivers of classification was investigated. The chemicals were tested in two independent runs by MatTek In Vitro Life Science Laboratories. Results of this study demonstrate very high specificity of both test protocols. With the existing prediction models described in the SOPs, the specificity of the Neat and Dilution method was 87% and 100%, respectively. The Dilution method was able to correctly predicting 66% of GHS Cat 2 chemicals, however, prediction of GHS Cat 1 chemicals was only 47%-55% using the current protocols. In order to achieve optimal prediction for all three classes, a testing strategy was developed which combines the most predictive time-points of both protocols and for tests liquids and solids separately. Using this new testing strategy, the sensitivity for predicting GHS Cat 1 and GHS Cat 2 chemicals was 73% and 64%, respectively and the very high specificity of 97% was maintained. None of the Cat 1 chemicals was underpredicted as GHS No Category. Further combination of the EpiOcular time-to-toxicity protocols with other validated in vitro systems evaluated in this project, should enable significant reduction and even possible replacement of the animal tests for the final assessment of the irritation potential in all of the GHS classes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    PubMed

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Driver fatigue detection based on eye state.

    PubMed

    Lin, Lizong; Huang, Chao; Ni, Xiaopeng; Wang, Jiawen; Zhang, Hao; Li, Xiao; Qian, Zhiqin

    2015-01-01

    Nowadays, more and more traffic accidents occur because of driver fatigue. In order to reduce and prevent it, in this study, a calculation method using PERCLOS (percentage of eye closure time) parameter characteristics based on machine vision was developed. It determined whether a driver's eyes were in a fatigue state according to the PERCLOS value. The overall workflow solutions included face detection and tracking, detection and location of the human eye, human eye tracking, eye state recognition, and driver fatigue testing. The key aspects of the detection system incorporated the detection and location of human eyes and driver fatigue testing. The simplified method of measuring the PERCLOS value of the driver was to calculate the ratio of the eyes being open and closed with the total number of frames for a given period. If the eyes were closed more than the set threshold in the total number of frames, the system would alert the driver. Through many experiments, it was shown that besides the simple detection algorithm, the rapid computing speed, and the high detection and recognition accuracies of the system, the system was demonstrated to be in accord with the real-time requirements of a driver fatigue detection system.

  4. Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

    PubMed

    Koh, Shizuka; Ikeda, Chikako; Takai, Yoshihiro; Watanabe, Hitoshi; Maeda, Naoyuki; Nishida, Kohji

    2013-09-01

    To evaluate the preliminary long-term efficacy of diquafosol ophthalmic solution for aqueous-deficient dry eye. Fifteen patients with mild-to-moderate aqueous-deficient dry eye were enrolled. After a washout period, the patients were treated with 3 % diquafosol ophthalmic solution for 6 months. We assessed 12 subjective dry eye symptoms, corneal and conjunctival staining with fluorescein, tear film break-up time (BUT), lower tear meniscus height measured with anterior-segment optical coherence tomography, Schirmer's testing, and adverse reactions at baseline and 1, 3, and 6 months after the start of treatment. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining, BUT, and tear meniscus height at 1 month and maintained the effectiveness for 6 months. Conjunctival staining significantly improved 3 and 6 months after treatment. No significant adverse reactions developed. Prolonged use of diquafosol ophthalmic solution for 6 months produced significant improvement both subjectively (dry eye symptom score) and objectively (ocular staining score and tear function tests) for aqueous-deficient dry eye.

  5. Prospective, randomized, controlled comparison of SYSTANE UD eye drops versus VISINE INTENSIV 1% EDO eye drops for the treatment of moderate dry eye.

    PubMed

    Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus

    2012-12-01

    The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.

  6. Associations between subjective happiness and dry eye disease: a new perspective from the Osaka study.

    PubMed

    Kawashima, Motoko; Uchino, Miki; Yokoi, Norihiko; Uchino, Yuichi; Dogru, Murat; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Mimura, Masaru; Tsubota, Kazuo

    2015-01-01

    Dry eye disease has become an important health problem. A lack of concordance between self-reported symptoms and the outcome of dry eye examinations has raised questions about dry eye disease. To explore the association between subjective happiness and objective and subjective symptoms of dry eye disease. The study adopted a cross-sectional design. All the employees of a company in Osaka, Japan. 672 Japanese office workers using Visual Display Terminals (age range: 26-64 years). The dry eye measurement tools included the Schirmer test, conjunctivocorneal staining, the tear film break-up time, as well as the administration of a dry eye symptoms questionnaire. Happiness was measured by the Subjective Happiness Scale. Dry eye examination parameters, dry eye symptoms questionnaires, and the Subjective Happiness Scale score. Of the 672 workers, 561 (83.5%) completed the questionnaires and examinations. The mean Subjective Happiness Scale score was 4.91 (SD = 1.01). This score was inversely correlated with the dry eye symptom score (r = -0.188, p < 0.001), but was not associated with objective findings which include conjunctivocorneal staining, low Schirmer test score, or low tear film break-up time. The level of subjective happiness was the lowest in the group without objective results, but reported subjective symptoms of dry eyes (p < 0.05). There is evidence of the relationship between subjective happiness and self-reported symptoms of dry eyes. Findings of this study revealed a new perspective on dry eye disease, including the potential for innovative treatments of a specific population with dry eye disease.

  7. Evaluation of Eye Metrics as a Detector of Fatigue

    DTIC Science & Technology

    2010-03-01

    eyeglass frames . The cameras are angled upward toward the eyes and extract real-time pupil diameter, eye-lid movement, and eye-ball movement. The...because the cameras were mounted on eyeglass -like frames , the system was able to continuously monitor the eye throughout all sessions. Overall, the...of “ fitness for duty” testing and “real-time monitoring” of operator performance has been slow (Institute of Medicine, 2004). Oculometric-based

  8. Traumatic eye injuries as a result of blunt impact

    NASA Astrophysics Data System (ADS)

    Clemente, Chiara; Esposito, Luca; Bonora, Nicola; Limido, Jerome; Lacome, Jean-Luc; Rossi, Tommaso

    2013-06-01

    The detachment or tearing of the retina in the human eye as a result of a collision is a phenomenon that occurs very often. This research is aimed at identifying and understanding the actual dynamic physical mechanisms responsible for traumatic eye injuries accompanying blunt impact, with particular attention to the damage processes that take place at the retina. To this purpose, a numerical and experimental investigation of the dynamic response of the eye during an impact event was performed. Numerical simulation of both tests was performed with IMPETUS-FEA, a general non-linear finite element software which offers NURBS finite element technology for the simulation of large deformation and fracture in materials. Computational results were compared with the experimental results on fresh enucleated porcine eyes impacted with airsoft pellets. The eyes were placed in a container filled with 10 percent ballistic gelatin simulating the fatty tissue surrounding the eye. A miniature pressure transducer was inserted into the eye bulb through the optic nerve in order to measure the pressure of the eye during blunt-projectile impacts. Each test was recorded using a high speed video camera. The ocular injuries observed in the impacted eyes were assessed by an ophthalmologist in order to evaluate the correlation between the pressure measures and the risk of retinal damage.

  9. Prevalence of dry eye syndrome in an adult population.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Kheirkhah, Ahmad; Emamian, Mohammad Hassan; Mehravaran, Shiva; Shariati, Mohammad; Fotouhi, Akbar

    2014-04-01

    To determine the prevalence of dry eye syndrome in the general 40- to 64-year-old population of Shahroud, Iran. Population-based cross-sectional study. Through cluster sampling, 6311 people were selected and 5190 participated. Assessment of dry eye was done in a random subsample of 1008 people. Subjective assessment for dry eye syndrome was performed using Ocular Surface Disease Index questionnaire. In addition, the following objective tests of dry eye syndrome were employed: Schirmer test, tear break-up time, and fluorescein and Rose Bengal staining using the Oxford grading scheme. Those with an Ocular Surface Disease Index score ≥23 were considered symptomatic, and dry eye syndrome was defined as having symptoms and at least one positive objective sign. The prevalence of dry eye syndrome was 8.7% (95% confidence interval 6.9-10.6). Assessment of signs showed an abnormal Schirmer score in 17.8% (95% confidence interval 15.5-20.0), tear break-up time in 34.2% (95% confidence interval 29.5-38.8), corneal fluorescein staining (≥1) in 11.3% (95% confidence interval 8.5-14.1) and Rose Bengal staining (≥3 for cornea and/or conjunctiva) in 4.9% (95% confidence interval 3.4-6.5). According to the Ocular Surface Disease Index scores, 18.3% (95% confidence interval 15.9-20.6) had dry eye syndrome symptoms. The prevalence of dry eye syndrome was significantly higher in women (P = 0.010) and not significantly associated with age (P = 0.291). The objective dry eye syndrome signs significantly increased with age. Based on the findings, the prevalence of dry eye syndrome in the studied population is in the mid-range. The prevalence is higher in women. Also, objective tests tend to turn abnormal at higher age. Pterygium is associated with dry eye syndrome and increased its symptoms. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  10. Non-Animal Testing Approach to EPA Labeling for Eye Irritation

    EPA Pesticide Factsheets

    This document is an update to EPA’s 2013 published alternative testing approach (using in vitro/ex vivo assays) for determination of eye irritation potential in the pesticide program under EPA's classification and labeling system.

  11. 29 CFR 1919.27 - Unit proof tests-winches, derricks and gear accessory thereto.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., goosenecks, eye plates, eye bolts, or other attachments), shall be tested with a proof load which shall..., a qualified technical office of an accredited gear certification agency, with the recognition that...

  12. Evaluation of point-of-care test for elevated tear matrix metalloproteinase 9 in post-LASIK dry eyes.

    PubMed

    Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal

    2016-09-01

    To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Mobile Apps for Eye Care in Canada: An Analysis of the iTunes Store.

    PubMed

    Rodin, Alexander; Shachak, Aviv; Miller, Aaron; Akopyan, Vladimir; Semenova, Nataliya

    2017-06-14

    Mobile phone screens can facilitate stimulation to various components of the visual system and many mobile apps are accepted as a means of providing clinical assessments for the oculo-visual system. Although many of these apps are intended for use in clinical settings, there is a growing number of apps in eye care developed for self-tests and eye exercises for lay people. These and other features, however, have not yet been well described. Our objective was to identify, describe, and categorize mobile apps related to eye care that are available to users in the Canadian iTunes market. We conducted an extensive search of the Apple iTunes Store for apps related to eye care. We used the terms "eye," "eye care," "vision," and "eye test" and included apps that are targeted at both lay people and medical professionals. We excluded apps whose primary function is not related to eye care. Eligible apps were categorized by primary purpose, based on how they were described by their developers in the iTunes Store. Our search yielded 10,657 apps, of which 427 met our inclusion criteria. After removing duplicates, 355 unique apps were subject to further review. We assigned the eligible apps to three distinct categories: 39/355 apps (11.0%) were intended for use by medical professionals, 236 apps (66.5%, 236/355) were intended for use by lay people, and 80 apps (22.5%, 80/355) were intended for marketing eye care and eye-care products. We identified 9 subcategories of apps based on the descriptions of their primary functions. Apps for medical professionals fell into three subcategories: clinical calculators (n=6), clinical diagnostic tools (n=18), and education and networking apps for professionals (n=15). Apps for lay people fell into four subcategories: self-testing (n=153), eye exercises (n=30), patient tools and low vision aids (n=35), and apps for patient education (n=18). Mixed-use apps (n=80) were placed into two subcategories: marketing of individual practitioners or eye-care products (n=72) and marketing of multiple eye-care products or professional services. The most extensive subcategory pertaining to eye care consisted of apps for use by lay people, especially for conducting self-tests (n=236). This study revealed a previously uncharacterized category of apps intended for use by doctors and patients, of which the primary goal is marketing of eye-care services and products (n=80). ©Alexander Rodin, Aviv Shachak, Aaron Miller, Vladimir Akopyan, Nataliya Semenova. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 14.06.2017.

  14. Eye movements during the Rorschach test in schizophrenia.

    PubMed

    Hori, Yasuko; Fukuzako, Hiroshi; Sugimoto, Yoko; Takigawa, Morikuni

    2002-08-01

    In order to understand relationships between scanning behaviors, characteristics of visual stimuli and the clinical symptoms in schizophrenia, eye movements of 37 schizophrenic patients and 36 controls were recorded using an eye-mark recorder during a free-response period in a Rorschach test. Four cards (I, II, V and VIII) were used. Data were analyzed during 15 s from the presentation of each card. For all cards, the number of eye fixations and the number of eye fixation areas were fewer, and total scanning length and mean scanning length were shorter for schizophrenic patients than for controls. For card II, in the non-popular response group, eye fixation frequency upon area 5 + 6 (red) was higher for schizophrenic patients. For card VIII, in the popular response group, eye fixation frequency upon area 5 + 6 (pink) was lower for schizophrenic patients. For cards II and VIII, the number of eye fixations was inversely correlated with negative symptoms. For card II, total scanning length tended to be inversely correlated with negative symptoms, and mean eye fixation time was correlated with negative symptoms. The number of eye fixation areas was inversely correlated with positive symptoms. For card VIII, eye fixation frequency in a stimulative area tended to be correlated with positive symptoms. Scanning behaviors in schizophrenic patients are affected by characteristics of visual stimuli, and partially by clinical symptoms.

  15. Expert System Diagnosis of Cataract Eyes Using Fuzzy Mamdani Method

    NASA Astrophysics Data System (ADS)

    Santosa, I.; Romla, L.; Herawati, S.

    2018-01-01

    Cataracts are eye diseases characterized by cloudy or opacity of the lens of the eye by changing the colour of black into grey-white which slowly continues to grow and develop without feeling pain and pain that can cause blindness in human vision. Therefore, researchers make an expert system of cataract eye disease diagnosis by using Fuzzy Mamdani and how to care. The fuzzy method can convert the crisp value to linguistic value by fuzzification and includes in the rule. So this system produces an application program that can help the public in knowing cataract eye disease and how to care based on the symptoms suffered. From the results of the design implementation and testing of expert system applications to diagnose eye disease cataracts, it can be concluded that from a trial of 50 cases of data, obtained test results accuracy between system predictions with expert predictions obtained a value of 78% truth.

  16. The Prevalence of Dry Eye and Sjögren Syndrome in Patients with Migraine.

    PubMed

    Sarac, Ozge; Kosekahya, Pinar; Yildiz Tasci, Yelda; Keklikoglu, Hava D; Deniz, Orhan; Erten, Şükran; Çağıl, Nurullah

    2017-06-01

    To evaluate the presence of dry eye and primary Sjögren syndrome (SS) in patients with migraine. In total, 46 eyes of 46 patients with migraine (group 1) and 50 eyes of 50 healthy subjects (group 2) were included in this study. Detailed ophthalmologic, neurologic and rheumatologic examination were performed on all participants. Ocular surface disease index questionnaire, tear function tests, visual analog scale for pain, serologic analysis were also performed. Dry eye symptoms and findings were significantly higher and more severe in group 1 when compared with group 2. Primary SS was not found in any of the participants. The migraine lifetime duration was negatively correlated with the tear function tests while it was positively correlated with the ocular surface disease index scores. Dry eye symptoms and findings are higher in migraine patients when compared with the healthy subjects without the presence of Sjögren syndrome.

  17. Macular dysfunction in patients with macula-on rhegmatogenous retinal detachments.

    PubMed

    Akiyama, Kunihiko; Fujinami, Kaoru; Watanabe, Ken; Noda, Toru; Miyake, Yozo; Tsunoda, Kazushige

    2018-06-01

    To assess macular function in patients with macula-on rhegmatogenous retinal detachments (RRDs) using focal macular electroretinography (FMERG). This is a prospective, observational case series of 27 patients diagnosed with a macula-on RRD. Foveal attachment was confirmed on spectral-domain optical coherence tomography. Eyes with any macular disorder, cataract, vitreous opacity or vitreous haemorrhage were excluded. FMERG was recorded in the affected and fellow eyes using a round stimulus 15° in diameter. The status of four retinal factors in the affected eyes was examined, that is, the number of involved quadrants, number of quadrants with retinal breaks, presence of an RRD invading the vascular arcade, and presence of a giant retinal tear. The implicit time and amplitude of the a-wave, b-wave and oscillatory potentials (OPs) were compared between the affected and fellow eyes using Wilcoxon signed-rank test. The influence of the four retinal factors on each FMERG component of the affected eyes was also evaluated using Mann-Whitney U  test and Kruskal-Wallis test. Significant reductions in the amplitudes of the a-waves (p=0.001), b-waves (p<0.001) and OPs (p=0.001) were observed in the affected eyes compared with the fellow eyes. There was no significant difference between the affected and fellow eyes in the implicit times of any components. None of the four retinal factors affected the parameters in the affected eyes. Altered FMERG responses suggested the presence of macular dysfunction in eyes with macula-on RRDs. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. An optomechanical model eye for ophthalmological refractive studies.

    PubMed

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  19. Utility of Novel Autoantibodies in the Diagnosis of Sjögren's Syndrome Among Patients With Dry Eye.

    PubMed

    Karakus, Sezen; Baer, Alan N; Agrawal, Devika; Gurakar, Merve; Massof, Robert W; Akpek, Esen K

    2018-04-01

    To investigate the value of 3 novel autoantibodies [salivary protein 1 (SP1), carbonic anhydrase 6 (CA6), and parotid secretory protein (PSP)] in differentiating Sjögren's syndrome (SS)-related dry eye from non-SS dry eye. Forty-six dry eye patients with SS (SS dry eye), 14 dry eye patients without SS (non-SS dry eye), and 25 controls were included. The 2012 American College of Rheumatology classification criteria were used for the diagnosis of SS. After a detailed review of systems, the Ocular Surface Disease Index questionnaire, Schirmer test without anesthesia, tear film breakup time, and ocular surface staining were performed to assess dry eye. All participants underwent serological testing using a commercially available finger prick kit. Thirty-seven patients with SS (80.4%) had a positive traditional autoantibody and 28 (60.9%) had a positive novel autoantibody. Traditional autoantibodies were absent in all non-SS dry eye patients and controls. Novel autoantibodies were present in 7/14 (50%) non-SS dry eye patients and 4/25 (16%) controls. Among 3 novel autoantibodies, anti-CA6 was significantly more prevalent in the SS and non-SS dry eye groups than in controls (52.2% vs. 42.9% vs. 8.0%, P = 0.001). Dry eye patients with positive anti-CA6 alone were significantly younger than patients with only traditional autoantibodies. Anti-CA6 was associated with worse dry eye signs and symptoms. Anti-CA6 was the most prevalent novel autoantibody in patients with dry eye, and was associated with younger age and more severe disease. Longitudinal studies are needed to determine whether anti-CA6 is a marker for early SS or perhaps another form of an autoimmune dry eye disease.

  20. Frequency doubling technology perimetry for detection of visual field progression in glaucoma: a pointwise linear regression analysis.

    PubMed

    Liu, Shu; Yu, Marco; Weinreb, Robert N; Lai, Gilda; Lam, Dennis Shun-Chiu; Leung, Christopher Kai-Shun

    2014-05-02

    We compared the detection of visual field progression and its rate of change between standard automated perimetry (SAP) and Matrix frequency doubling technology perimetry (FDTP) in glaucoma. We followed prospectively 217 eyes (179 glaucoma and 38 normal eyes) for SAP and FDTP testing at 4-month intervals for ≥36 months. Pointwise linear regression analysis was performed. A test location was considered progressing when the rate of change of visual sensitivity was ≤-1 dB/y for nonedge and ≤-2 dB/y for edge locations. Three criteria were used to define progression in an eye: ≥3 adjacent nonedge test locations (conservative), any three locations (moderate), and any two locations (liberal) progressed. The rate of change of visual sensitivity was calculated with linear mixed models. Of the 217 eyes, 6.1% and 3.9% progressed with the conservative criteria, 14.5% and 5.6% of eyes progressed with the moderate criteria, and 20.1% and 11.7% of eyes progressed with the liberal criteria by FDTP and SAP, respectively. Taking all test locations into consideration (total, 54 × 179 locations), FDTP detected more progressing locations (176) than SAP (103, P < 0.001). The rate of change of visual field mean deviation (MD) was significantly faster for FDTP (all with P < 0.001). No eyes showed progression in the normal group using the conservative and the moderate criteria. With a faster rate of change of visual sensitivity, FDTP detected more progressing eyes than SAP at a comparable level of specificity. Frequency doubling technology perimetry can provide a useful alternative to monitor glaucoma progression.

  1. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  2. Do Adults with High Functioning Autism or Asperger Syndrome Differ in Empathy and Emotion Recognition?

    PubMed

    Montgomery, Charlotte B; Allison, Carrie; Lai, Meng-Chuan; Cassidy, Sarah; Langdon, Peter E; Baron-Cohen, Simon

    2016-06-01

    The present study examined whether adults with high functioning autism (HFA) showed greater difficulties in (1) their self-reported ability to empathise with others and/or (2) their ability to read mental states in others' eyes than adults with Asperger syndrome (AS). The Empathy Quotient (EQ) and 'Reading the Mind in the Eyes' Test (Eyes Test) were compared in 43 adults with AS and 43 adults with HFA. No significant difference was observed on EQ score between groups, while adults with AS performed significantly better on the Eyes Test than those with HFA. This suggests that adults with HFA may need more support, particularly in mentalizing and complex emotion recognition, and raises questions about the existence of subgroups within autism spectrum conditions.

  3. Changes in tear volume and ocular symptoms of patients receiving oral anticancer drug S-1.

    PubMed

    Kuriki, Reiko; Hata, Tsuyoshi; Nakayama, Kinuyo; Ito, Yuichi; Misawa, Kazunari; Ito, Seiji; Tatematsu, Michiko; Kaneda, Norio

    2018-01-01

    Most eye disorders are not fatal but may deteriorate the quality of life of a patient. The eye disorder that is most frequently reported in the cancer chemotherapy is associated with the combination of tegafur/gimeracil/potassium oxonate (S-1). However, preventive methods or treatment methods for the eye disorder have not yet been established. This study aimed to determine changes in tear volume and subjective ocular symptoms during the treatment period in patients receiving S-1 monotherapy for early detection of adverse effects in the eye and establishment of its treatment methods. This study included eleven patients receiving S-1 monotherapy as a postoperative adjuvant chemotherapy for gastric cancer. Six subjective ocular symptoms including watering eyes were evaluated and changes in tear volume measured by the Schirmer's test in patients receiving S-1 during the treatment period. In the present study, the patients were divided into "no watering eyes" (patients not experienced watering eyes) group and "watering eyes" (patients experienced watering eyes even once) group. Six out of eleven patients developed watering eyes after receiving S-1 monotherapy. Among these, the earliest onset occurred on the 2nd week after oral administration. Watering eyes and eye discharge were highly related in patients having a trouble in daily life due to the decreased QOL. Changes in tear volume in the "watering eyes" group significantly increased compared to the "no watering eyes" group during the treatment period, especially when the patients had no subjective symptom of the increased tear volume. It is essential to prevent eye disorders including watering eyes as an adverse effect of S-1 administration. The present study recommends that the tear volume should be periodically measured using Schirmer's test, and the patient should be interviewed regarding the subjective ocular symptoms for the early detection of watering eyes caused by S-1 administration. If the tear volume can not be measured periodically, medical staffs should pay attention to the patient with eye discharge.

  4. The Efficacy of Eye Movement Desensitization and Reprocessing Therapy Technique in the Treatment of Test Anxiety of College Students.

    ERIC Educational Resources Information Center

    Enright, Matthew; Baldo, Tracy D.; Wykes, Scott D.

    2000-01-01

    Explores the efficacy of eye movement desensitization and reprocessing (EMDR) in the treatment of test anxiety. Thirty-five college students with test anxiety were assigned to either a treatment or delayed treatment control group. EMDR was shown to be effective in reducing overall test anxiety as well as "emotionality" and…

  5. Theory of Mind and Selective Attention, Response Inhibition, Cognitive Flexibility in Patients with Schizophrenia.

    PubMed

    Eşsizoğlu, Altan; Köşger, Ferdi; Akarsu, Ferdane Özlem; Özaydin, Özer; Güleç, Gülcan

    2017-06-01

    The aims of the current study are to investigate the relationship between selective attention, response inhibition, and cognitive flexibility that are among executive functions and sociocognitive and socioperceptual theory of mind (ToM) functions and also to investigate whether selective attention, response inhibition, and cognitive flexibility are predictive factors for ToM functions in patients with schizophrenia. Forty-seven patients diagnosed with schizophrenia and a control group consisting of 42 individuals were administered demographic information form, Wisconsin card sorting test (WCST), Stroop test, Eye test, Hinting test. Positive and negative syndrome scale was applied to the schizophrenia group. In comparison to the control group, the schizophrenia group performed significantly worse on Eyes test and Hinting test. Eyes Test score and age, WCST perseverative error scores were significantly negatively correlated; education and WCST categories achieved scores were significantly positively correlated in patients with schizophrenia. Age and cognitive flexibility were found to predict the Eyes test score in patients with schizophrenia. ToM functions that are important in maintaining socioperceptual functioning are closely related with cognitive flexibility, and impairment in cognitive flexibility may predict the ToM functions in patients with schizophrenia.

  6. The efficacy, sensitivity, and specificity of strip meniscometry in conjunction with tear function tests in the assessment of tear meniscus.

    PubMed

    Ibrahim, Osama M A; Dogru, Murat; Ward, Samantha K; Matsumoto, Yukihiro; Wakamatsu, Tais Hitomi; Ishida, Katsushi; Tsuyama, Atsushi; Kojima, Takashi; Shimazaki, Jun; Tsubota, Kazuo

    2011-04-06

    To evaluate the specificity and sensitivity of strip meniscometry (SM) testing in conjunction with tear function tests in the diagnosis of dry eye (DE) disease and to investigate the effect of SM on reflex tearing. One hundred seven left eyes of 107 patients with definite DE disease according to the Japanese DE diagnostic criteria and 68 left eyes of 68 age- and sex-matched control subjects were studied. Tear meniscus height (TMH) measurements, fluorescein tear film break-up time (FTBUT), fluorescein (F) and rose bengal (RB) staining, and Schirmer's test-1 (ST) were also performed. The assessment of reflex tearing before and after SM application was assessed with a graticule scale at the slit lamp and by optical coherence tomography. The sensitivity and specificity of SM alone and in combination with tear function tests were also sought. The SM scores, TMH measurements, FTBUTs, and STs were significantly lower in dry eye patients than in the controls (P < 0.001). The RB and F staining scores were significantly higher in the dry eye group than in the control group (P < 0.001). The meniscometry strips did not induce significant changes in relation to reflex tearing. SM had an acceptable sensitivity and specificity. SM is a swift, noninvasive, promising method of assessing tear meniscus volume. The combined SM and FTBUT examination appears to be a sensitive approach to the assessment of dry eye disease.

  7. Effects of individual differences in verbal skills on eye-movement patterns during sentence reading

    PubMed Central

    Kuperman, Victor; Van Dyke, Julie A.

    2011-01-01

    This study is a large-scale exploration of the influence that individual reading skills exert on eye-movement behavior in sentence reading. Seventy one non-college-bound 16–24 year-old speakers of English completed a battery of 18 verbal and cognitive skill assessments, and read a series of sentences as their eye movements were monitored. Statistical analyses were performed to establish what tests of reading abilities were predictive of eye-movement patterns across this population and how strong the effects were. We found that individual scores in rapid automatized naming and word identification tests (i) were the only participant variables with reliable predictivity throughout the time-course of reading; (ii) elicited effects that superceded in magnitude the effects of established predictors like word length or frequency; and (iii) strongly modulated the influence of word length and frequency on fixation times. We discuss implications of our findings for testing reading ability, as well as for research of eye-movements in reading. PMID:21709808

  8. Visual acuity test

    MedlinePlus

    ... contact lenses and stand or sit 20 feet (6 meters) from the eye chart. You will keep both eyes open. You will be asked to cover one eye with the palm of your hand, a piece of paper, or a small paddle while you ...

  9. Central Connections of the Lacrimal Functional Unit.

    PubMed

    Willshire, Catherine; Buckley, Roger J; Bron, Anthony J

    2017-08-01

    To study the contribution of each eye to the reflex tear response, after unilateral and bilateral topical anesthesia. A closed-eye, modified Schirmer test was performed bilaterally in 8 normal subjects, in a controlled environment chamber set to 23°C, 45% relative humidity, and 0.08 m/s airflow. Eye drops were instilled into each eye 10 minutes before the Schirmer test. Experiments were as follows: 1) bilateral saline (control), 2) unilateral anesthesia (ipsilateral anesthetic; contralateral saline), and 3) bilateral anesthesia. There was no difference in between-eye wetting lengths in the saline control eyes (P = 0.394) or the bilaterally anesthetized eyes (P = 0.171). The wetting length was reduced in both eyes after bilateral anesthesia compared with saline controls (P = 0.001; P ≤ 0.0005). After unilateral anesthesia, the wetting length was reduced in the anesthetized eye compared with its saline control by 51.4% (P ≤ 0.0005) and compared with its fellow, unanesthetized eye (P = 0.005). The fellow eye value was also reduced compared with its saline control (P = 0.06). The wetting length was reduced by topical anesthesia, when instilled bilaterally and ipsilaterally. The latter response implies an ipsilateral, reflex sensory drive to lacrimal secretion. In the unanesthetized fellow eye, the reduction compared with its saline control was not quite significant. This implies a relative lack of central, sensory, reflex cross-innervation, although the possibility cannot entirely be ruled out. These results are relevant to the possibility of reflex lacrimal compensation from a normal fellow eye, in cases of unilateral corneal anesthesia.

  10. Eye-Tracking as a Tool in Process-Oriented Reading Test Validation

    ERIC Educational Resources Information Center

    Solheim, Oddny Judith; Uppstad, Per Henning

    2011-01-01

    The present paper addresses the continuous need for methodological reflection on how to validate inferences made on the basis of test scores. Validation is a process that requires many lines of evidence. In this article we discuss the potential of eye tracking methodology in process-oriented reading test validation. Methodological considerations…

  11. Magnetic eye tracking in mice

    PubMed Central

    Payne, Hannah L

    2017-01-01

    Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455

  12. Associations between Subjective Happiness and Dry Eye Disease: A New Perspective from the Osaka Study

    PubMed Central

    Kawashima, Motoko; Uchino, Miki; Yokoi, Norihiko; Uchino, Yuichi; Dogru, Murat; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Mimura, Masaru; Tsubota, Kazuo

    2015-01-01

    Importance Dry eye disease has become an important health problem. A lack of concordance between self-reported symptoms and the outcome of dry eye examinations has raised questions about dry eye disease. Objective To explore the association between subjective happiness and objective and subjective symptoms of dry eye disease. Design The study adopted a cross-sectional design. Setting All the employees of a company in Osaka, Japan. Participants 672 Japanese office workers using Visual Display Terminals (age range: 26–64 years). Methods The dry eye measurement tools included the Schirmer test, conjunctivocorneal staining, the tear film break-up time, as well as the administration of a dry eye symptoms questionnaire. Happiness was measured by the Subjective Happiness Scale. Main Outcome Measures Dry eye examination parameters, dry eye symptoms questionnaires, and the Subjective Happiness Scale score. Results Of the 672 workers, 561 (83.5%) completed the questionnaires and examinations. The mean Subjective Happiness Scale score was 4.91 (SD = 1.01). This score was inversely correlated with the dry eye symptom score (r = -0.188, p < 0.001), but was not associated with objective findings which include conjunctivocorneal staining, low Schirmer test score, or low tear film break-up time. The level of subjective happiness was the lowest in the group without objective results, but reported subjective symptoms of dry eyes (p < 0.05). Conclusions and Relevance There is evidence of the relationship between subjective happiness and self-reported symptoms of dry eyes. Findings of this study revealed a new perspective on dry eye disease, including the potential for innovative treatments of a specific population with dry eye disease. PMID:25830665

  13. Sex, eye size, and the rate of myopic eye growth due to form deprivation in outbred white leghorn chickens.

    PubMed

    Chen, Yen-Po; Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; To, Chi Ho; Schaeffel, Frank; Guggenheim, Jeremy A

    2010-02-01

    There is considerable variation in the degree of form-deprivation myopia (FDM) induced in chickens by a uniform treatment regimen. Sex and pretreatment eye size have been found to be predictive of the rate of FD-induced eye growth. Therefore, this study was undertaken to test whether the greater rate of myopic eye growth in males is a consequence of their larger eyes or of some other aspect of their sex. Monocular FDM was induced in 4-day-old White Leghorn chicks for 4 days. Changes in ocular component dimensions and refractive error were assessed by A-scan ultrasonography and retinoscopy, respectively. Sex identification of chicks was performed by DNA test. Relationships between traits were assessed by multiple regression. FD produced (mean +/- SD) 13.47 +/- 3.12 D of myopia and 0.47 +/- 0.14 mm of vitreous chamber elongation. The level of induced myopia was not significantly different between the sexes, but the males had larger eyes initially and showed greater myopic eye growth than did the females. In multiple linear regression analysis, the partial correlation between sex and the degree of induced eye growth remained significant (P = 0.008) after adjustment for eye size, whereas the partial correlation between initial eye size and the degree of induced eye growth was no longer significant after adjustment for sex (P = 0.11). After adjustment for other factors, the chicks' sex accounted for 6.4% of the variation in FD-induced vitreous chamber elongation. The sex of the chick influences the rate of experimentally induced myopic eye growth, independent of its effects on eye size.

  14. Pattern of eye diseases among welders in a Nigeria community.

    PubMed

    Ajayi Iyiade, A; Omotoye Olusola, J

    2012-06-01

    Welders have been identified as a high risk group for eye disorders due to their exposure to ultraviolet radiation. To determine the prevalence and types of eye diseases amongst welders in Ile-Ife, Osun state. This is a cross sectional descriptive study of 405 consenting welders. Information on socio-demographic characteristics was obtained using a pre-tested proforma and all subjects had visual actuity test, anterior and posterior segments examination, test of stereopsis and macular function. Two hundred and seventy five (67.9%) of the respondents were arc welders, 99(22.5%) were gas welders while 39(9.6%) utilized both welding techniques. The age of the respondents ranged from 16 years to 80 years with a mean of 38 ± 13 years. Conjunctival degenerative disorders like pingueculum (50.1%) and pterygium(17.5%) constituted the commonest eye disorders among the welders. There were 6 blind eyes of 5 welders with pigmentary maculopathy accounting for the single case of bilateral blindness. There is a greater odd in developing pingueculum and Pterygium (OR=1.015, 1.039 respectively) in arc welders than in gas welders. Pingueculum, Pterygium, corneal opacity, and pigmentary macular deposits were the common eye disorders among welders.

  15. Results of selected ophthalmic diagnostic tests for clinically normal Syrian hamsters (Mesocricetus auratus).

    PubMed

    Rajaei, Seyed Mehdi; Mood, Maneli Ansari; Sadjadi, Reza; Williams, David L

    2016-01-01

    To determine values for tear production, horizontal palpebral fissure length (HPFL), eye blink frequency, and intraocular pressure (IOP) in healthy Syrian hamsters (Mesocricetus auratus). 40 healthy adult Syrian hamsters (80 eyes). Tear production was measured with the phenol red thread test (PRTT), modified Schirmer tear test (mSTT), and endodontic absorbent paper points tear test (EAPPTT). The IOP was measured by use of rebound tonometry. Correlations between test results and body weight were evaluated. Mean ± SD values for the IOP, PRTT, EAPPTT, mSTT, HPFL, and blink frequency for all 80 eyes were 4.55 ± 1.33 mm Hg, 5.57 ± 1.51 mm/15 s, 4.52 ± 1.55 mm/min, 2.07 ± 0.97 mm/min, 5.84 ± 0.45 mm, and 1.68 ± 0.43 blinks/min, respectively. For all variables, values did not differ significantly between the right and left eyes or between males and females. There was no correlation between measured variables and body weight. Results for this study provided information on values for the IOP, PRTT, mSTT, EAPPTT, HPFL, and eye blink frequency in healthy Syrian hamsters. It was important to determine reference intervals for this species because they commonly are kept as pets or used as research animals.

  16. Matrix Metalloproteinase 9 Testing in Dry Eye Disease Using a Commercially Available Point-of-Care Immunoassay.

    PubMed

    Messmer, Elisabeth M; von Lindenfels, Victoria; Garbe, Alexandra; Kampik, Anselm

    2016-11-01

    To measure matrix metalloproteinase 9 (MMP-9) in the tear film of patients with dry eye disease (DED) compared with controls and to correlate clinical findings. In a prospective study, 101 patients and controls underwent MMP-9 testing of the tear film. Thereafter, they were evaluated for symptoms and signs of DED. Included patients were those who showed 3 of the following 4 dry eye criteria: ocular surface disease index (OSDI) score of more than 12, tear film break-up time (TBUT) of 10 seconds or less, Schirmer test results without anesthesia of less than 10 mm/5 minutes, and corneal staining results of 1 or more. Fifty-four healthy eyes and 47 eyes fulfilling diagnostic criteria for DED of various levels of severity were included in this study. The tear film was analyzed for MMP-9 by a commercially available test (InflammaDry; Rapid Pathogen Screening, Inc, Sarasota, FL) detecting MMP-9 levels of more than 40 ng/ml. Symptoms and signs of DED were evaluated using the OSDI questionnaire, TBUT, conjunctival and corneal staining, Schirmer test results without anesthesia, and meibomian gland examination. These findings were correlated to results of the MMP-9 test in tears. Positive MMP-9 results in tears. In 19 of 47 patients confirmed with dry eye (40.4%) and in 3 of 54 controls (5.6%), the MMP-9 results were positive. This difference was statistically significant (P < 0.001). Thus, the MMP-9 results indicated a clinically significant inflammation in 40% of dry eye patients. Positive results correlated well with subjective symptoms of DED evaluated by OSDI (P = 0.001), TBUT of less than 5 seconds (P < 0.013), Schirmer test results (P < 0.001), conjunctival staining (P < 0.001), and corneal staining (P = 0.007). Moreover, MMP-9 results correlated with the number of obstructed meibomian ducts (P = 0.005) and a pathologic meibomian gland secretion (P = 0.001). The MMP-9 results were increased significantly in women (P < 0.001) and in patients with autoimmune disease (P = 0.005), especially Sjögren's syndrome (P = 0.001) and thyroid disease (P = 0.012). Matrix metalloproteinase 9 testing in DED is a valuable new diagnostic tool. It correlated well with other dry eye tests and identified the presence of ocular surface inflammation in 40% of confirmed dry eye patients. It may be especially helpful to identify patients with ocular surface inflammation and autoimmune disease and may facilitate the decision to institute anti-inflammatory treatment in these patients. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.

    PubMed

    Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E

    2016-11-01

    To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.

  18. Fixation Patterns and Reading Rates in Eyes with Central Scotomas from Advanced Atrophic Age-related Macular Degeneration and Stargardt Disease

    PubMed Central

    Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.

    2009-01-01

    Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306

  19. Long-term visual outcomes in extremely low-birth-weight children (an American Ophthalmological Society thesis).

    PubMed

    Spencer, Rand

    2006-01-01

    The goal is to analyze the long-term visual outcome of extremely low-birth-weight children. This is a retrospective analysis of eyes of extremely low-birth-weight children on whom vision testing was performed. Visual outcomes were studied by analyzing acuity outcomes at >/=36 months of adjusted age, correlating early acuity testing with final visual outcome and evaluating adverse risk factors for vision. Data from 278 eyes are included. Mean birth weight was 731g, and mean gestational age at birth was 26 weeks. 248 eyes had grating acuity outcomes measured at 73 +/- 36 months, and 183 eyes had recognition acuity testing at 76 +/- 39 months. 54% had below normal grating acuities, and 66% had below normal recognition acuities. 27% of grating outcomes and 17% of recognition outcomes were /=3 years of age. A slower-than-normal rate of early visual development was predictive of abnormal grating acuity (P < .0001) and abnormal recognition acuity (P < .0001) at >/=3 years of age. Eyes diagnosed with maximal retinopathy of prematurity in zone I had lower acuity outcomes (P = .0002) than did those with maximal retinopathy of prematurity in zone II/III. Eyes of children born at 28 weeks gestational age. Eyes of children with poorer general health after premature birth had a 5.3 times greater risk of abnormal recognition acuity. Long-term visual development in extremely low-birth-weight infants is problematic and associated with a high risk of subnormal acuity. Early acuity testing is useful in identifying children at greatest risk for long-term visual abnormalities. Gestational age at birth of

  20. Osmolarity of prevalent eye drops, side effects, and therapeutic approaches.

    PubMed

    Dutescu, Ralf M; Panfil, Claudia; Schrage, Norbert

    2015-05-01

    Little is known about how the osmolarity of ophthalmic formulations affects the ocular surface. Because hyperosmolar eye drops could be therapeutic for treating corneal edema, this article presents an ex vivo model of corneal edema for testing ophthalmic drugs based on their osmolarity. The respective osmolarity of common eye drops found in the German market is also analyzed here. For modeling corneal edema, an Ex Vivo Eye Irritation Test was used to simulate an ocular anterior chamber with a physiological corneal barrier. To induce corneal edema, the anterior chamber was supplied with a hypoosmolar medium (148 mOsm/L) for 24 hours. Preserved and preservative-free 5% sodium chloride (hyperosmolar Omnisorb and Ocusalin 5% UD) were used for 1 hour, on 5 corneas each, to test their efficiency to reduce corneal edema in this model. Corneal thickness was determined by optical coherence tomography. Osmolarity of 87 common eye drops was measured by freezing point osmometry. Ex vivo, the tested hypoosmolar condition induced corneal edema from 450 μm (±50 μm) at baseline to 851 μm (±94 μm, P < 0.0001). Omnisorb and Ocusalin 5% UD significantly reduced the corneal thickness by 279 μm (±28 μm, P < 0.001) for Omnisorb and 258 μm (±29 μm, P < 0.001) for Ocusalin 5% UD. Forty-three (49%) of the tested products had an osmolarity below and 44 (51%) above the physiological tear osmolarity of 289 mOsm/L. Osmolarity values of less than 200 mOsm/L were found in lubricant drops. The highest osmolarity was detected in Omnisorb (1955 mOsm/L). The Ex Vivo Eye Irritation Test has proven to be a reliable novel model of corneal edema for evaluating osmotic eye drops. Osmolarity measurements revealed a wide range from hypotonic to hypertonic formulations for commonly marketed ophthalmic drugs.

  1. Reduction of foveal bulges and other anatomical changes in fellow eyes of patients with unilateral idiopathic macular hole without vitreomacular pathologic changes.

    PubMed

    Delas, Barbara; Julio, Gemma; Fernández-Vega, Álvaro; Casaroli-Marano, Ricardo P; Nadal, Jeroni

    2017-11-01

    To compare the foveal characteristics in fellow eyes (FE) of patients with unilateral idiopathic macular hole without vitreomacular pathologic changes with eyes of healthy controls. Forty-seven FE and 52 eyes of 52 age- and sex-matched healthy controls were studied. Quantitative assessment of the dome-shaped appearance of the hyperreflective lines that represent external limiting membrane (ELM_bulge) and inner outer segment junctions (IS/OS_bulge) were made by optical coherence tomography (OCT) images. Inner retinal complex thickness (IRCT) was quantitatively assessed at 1000 and 2000 μm of the foveal center in nasal and temporal quadrants. Presence of alterations in the inner retinal outer layers and central foveal thickness (CFT) were also analyzed. Significantly lower ELM_bulge (p < 0.0001; Mann-Whitney test) and IS/OS_bulge (p < 0.001; student t test) and higher cases with COST alterations, expressed as a diffuse line (p < 0.006; Chi 2 test) were found in FE than control eyes. IRCT were significantly reduced in FE at all the studied locations when comparing to control eyes (p < 0.05; student t test), maintaining anatomical proportionality among locations. FE without pathologic vitreomacular interactions seems to present some central cone alterations that may be related to other causes than vitreomacular traction.

  2. CEFR and Eye Movement Characteristics during EFL Reading: The Case of Intermediate Readers

    ERIC Educational Resources Information Center

    Dolgunsöz, Emrah; Sariçoban, Arif

    2016-01-01

    This study primarily aims to (1) examine the relationship between foreign language reading proficiency and eye movements during reading, and (2) to describe eye movement differences between two CEFR proficiency groups (B1 and B2) by using eye tracking technique. 57 learners of EFL were tested under two experimental conditions: Natural L2 reading…

  3. EYE MOVEMENT RECORDING AND NONLINEAR DYNAMICS ANALYSIS – THE CASE OF SACCADES#

    PubMed Central

    Aştefănoaei, Corina; Pretegiani, Elena; Optican, L.M.; Creangă, Dorina; Rufa, Alessandra

    2015-01-01

    Evidence of a chaotic behavioral trend in eye movement dynamics was examined in the case of a saccadic temporal series collected from a healthy human subject. Saccades are highvelocity eye movements of very short duration, their recording being relatively accessible, so that the resulting data series could be studied computationally for understanding the neural processing in a motor system. The aim of this study was to assess the complexity degree in the eye movement dynamics. To do this we analyzed the saccadic temporal series recorded with an infrared camera eye tracker from a healthy human subject in a special experimental arrangement which provides continuous records of eye position, both saccades (eye shifting movements) and fixations (focusing over regions of interest, with rapid, small fluctuations). The semi-quantitative approach used in this paper in studying the eye functioning from the viewpoint of non-linear dynamics was accomplished by some computational tests (power spectrum, portrait in the state space and its fractal dimension, Hurst exponent and largest Lyapunov exponent) derived from chaos theory. A high complexity dynamical trend was found. Lyapunov largest exponent test suggested bi-stability of cellular membrane resting potential during saccadic experiment. PMID:25698889

  4. The effect of an eye health promotion program on the health protective behaviors of primary school students

    PubMed Central

    Kirag, Nukhet; Temel, Ayla Bayik

    2018-01-01

    INTRODUCTION: Undiagnosed and uncorrected refractive errors in childhood can negatively affect the development of vision and cause students to have low academic success and even quit school before graduation. This study aims to determine the effects of an eye health promotion program on the health protective behaviors of primary school students. MATERIALS AND METHODS: This experimental study using a pretest-posttest design with a control group was conducted in three public primary schools in Aydın, a city in the Western Anatolia Region of Turkey, between April and November 2014. The eye health promotion program was provided by the researchers to the experimental Group 2 days in 4 weeks. The data were analyzed using the t-test, Chi-square analysis, the Mann–Whitney U-test, the Wilcoxon signed-rank test, and the McNemar test. RESULTS: The average age of the students was identified as 9.0 ± 3.64 years. The students wearing glasses all in the experimental group and 53.3% in the control group were found to always wear their glasses after the education program was completed (P < 0.05). These students, 97.9% in the experimental group and 58.1% in the control group underwent eye examinations from an ophthalmologist (P < 0.05). The eye health protective behaviors of the experimental group were found to have positively changed in the final follow-up, compared to the control group (P < 0.05). CONCLUSION: The eye health promotion program was found to be effective in improving eye health protective behaviors within the experimental group. PMID:29619388

  5. Multiple sclerosis and optic nerve: an analysis of retinal nerve fiber layer thickness and color Doppler imaging parameters

    PubMed Central

    Akçam, H T; Capraz, I Y; Aktas, Z; Batur Caglayan, H Z; Ozhan Oktar, S; Hasanreisoglu, M; Irkec, C

    2014-01-01

    Purpose To compare both retinal nerve fiber layer thickness and orbital color Doppler ultrasonography parameters in patients with multiple sclerosis (MS) versus healthy controls. Methods This is an observational case–control study. Forty eyes from MS patients and twenty eyes from healthy volunteers were examined. Eyes were classified into three groups as group 1, eyes from MS patients with previous optic neuritis (n=20); group 2, eyes from MS patients without previous optic neuritis (n=20); and group 3, eyes from healthy controls (n=20). Following complete ophthalmologic examination and retinal nerve fiber layer thickness measurement for each group, blood flow velocities of posterior ciliary arteries, central retinal artery, ophthalmic artery, and superior ophthalmic vein were measured. Pourcelot index (resistive index), an indicator of peripheral vascular resistance, was also calculated. The statistical assessment was performed with the assistance of Pearson's Chi-square test, Mann–Whitney U-test, Kruskal–Wallis test, and Spearman's correlation test. Results The studied eyes exposed similar values in terms of intraocular pressure and central corneal thickness, implying no evidence in favor of glaucoma. All nerve fiber layer thickness values, except superior nasal quadrants, in group 1 were found to be significantly thinner than groups 2 and 3. Blood flow velocity and mean resistivity index parameters were similar in all the groups. Conclusions In MS patients, especially with previous optic neuritis, diminished retinal nerve fiber layer thickness was observed. Contrary to several studies in the current literature, no evidence supporting potential vascular origin of ocular involvement in MS was found. PMID:25081285

  6. Sunglasses with thick temples and frame constrict temporal visual field.

    PubMed

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  7. Vision Screening by Color Photography

    NASA Technical Reports Server (NTRS)

    Jayroe, R.; Richardson, J. R.; Kerr, J.; Hay, S.; Mcbride, R.

    1985-01-01

    Screening test developed for detecting a range of vision defects in eye, including common precursors to amblyopia. Test noninvasive, safe, and administered easily in field by operator with no medical training. Only minimal momentary cooperation of subject required: Thus, test shows promise for use with very young children. Test produces color-slide images of retinas of eyes under specially-controlled lighting conditions. Trained observer screens five children per minute.

  8. Are Long-Term Chloroquine or Hydroxychloroquine Users Being Checked Regularly for Toxic Maculopathy?

    PubMed Central

    Nika, Melisa; Blachley, Taylor S.; Edwards, Paul; Lee, Paul P.; Stein, Joshua D.

    2014-01-01

    Importance According to evidence-based, expert recommendations, long-term users of chloroquine (CQ) or hydroxychloroquine (HCQ) should undergo regular visits to eye-care providers and diagnostic testing to check for maculopathy. Objective To determine whether patients with rheumatoid arthritis (RA) or systemic lupus erythematosus (SLE) taking CQ or HCQ are regularly visiting eye-care providers and being screened for maculopathy. Setting, Design and Participants Patients with RA or SLE who were continuously enrolled in a particular managed-care network for ≥5 years during 2001-2011 were studied. Patients' amount of CQ/HCQ use in the 5 years since initial RA/SLE diagnosis was calculated, along with their number of eye-care visits and diagnostic tests for maculopathy. Those at high risk for maculopathy were identified. Visits to eye providers and diagnostic testing for maculopathy were assessed for each enrollee over the study period. Logistic regression was performed to assess potential factors associated with regular eye-care-provider visits (≥3 in 5 years) among CQ/HCQ users, including those at greatest risk for maculopathy. Main Outcome Measures Among CQ/HCQ users and those at high risk for toxic maculopathy, the proportions with regular eye-care visits and diagnostic testing, and the likelihood of regular eye-care visits (odds ratios [ORs] with 95% confidence intervals [CI]). Results Among 18,051 beneficiaries with RA or SLE, 6,339 (35.1%) had ≥1 record of HCQ/CQ use and 1,409 (7.8%) used HCQ/CQ for ≥4 years. Among those at high risk for maculopathy, 27.9% lacked regular eye-provider visits, 6.1% had no visits to eye providers, and 34.5% had no diagnostic testing for maculopathy during the 5-year period. Among high-risk patients, each additional month of HCQ/CQ use was associated with a 2.0%-increased likelihood of regular eye care (adjusted OR=1.02, CI=1.01-1.03). High-risk patients whose SLE/RA were managed by rheumatologists had a 77%-increased likelihood of regular eye care (adjusted OR=1.77, CI=1.27-2.47), relative to other patients. Conclusions and Relevance In this insured population, many patients at high risk for HCQ/CQ-associated maculopathy are not undergoing routine monitoring for this serious side effect. Future studies should explore factors contributing to suboptimal adherence to expert guidelines and the potential impact on patients' vision-related outcomes. PMID:24970348

  9. MAPK Target Sites of Eyes Absent Are Not Required for Eye Development or Survival in Drosophila

    PubMed Central

    Jusiak, Barbara; Abulimiti, Abuduaini; Haelterman, Nele; Chen, Rui; Mardon, Graeme

    2012-01-01

    Eyes absent (Eya) is a highly conserved transcription cofactor and protein phosphatase that plays an essential role in eye development and survival in Drosophila. Ectopic eye induction assays using cDNA transgenes have suggested that mitogen activated protein kinase (MAPK) activates Eya by phosphorylating it on two consensus target sites, S402 and S407, and that this activation potentiates the ability of Eya to drive eye formation. However, this mechanism has never been tested in normal eye development. In the current study, we generated a series of genomic rescue transgenes to investigate how loss- and gain-of-function mutations at these two MAPK target sites within Eya affect Drosophila survival and normal eye formation: eya+GR, the wild-type control; eyaSAGR, which lacks phosphorylation at the two target residues; and eyaSDEGR, which contains phosphomimetic amino acids at the same two residues. Contrary to the previous studies in ectopic eye development, all eya genomic transgenes tested rescue both eye formation and survival equally effectively. We conclude that, in contrast to ectopic eye formation, MAPK-mediated phosphorylation of Eya on S402 and S407 does not play a role in normal development. This is the first study in Drosophila to evaluate the difference in outcomes between genomic rescue and ectopic cDNA-based overexpression of the same gene. These findings indicate similar genomic rescue strategies may prove useful for re-evaluating other long-standing Drosophila developmental models. PMID:23251383

  10. Automatic optometer operates with infrared test pattern

    NASA Technical Reports Server (NTRS)

    Cornsweet, T. N.; Crane, H. D.

    1970-01-01

    Refractive strength of human eye is monitored by optometer that automatically and continuously images infrared test pattern onto the retina. Condition of focus of the eye at any instant is determined from optometer settings needed to maintain focus of the pattern on the retina.

  11. A Sticky Situation.

    PubMed

    Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq

    2018-04-26

    An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Evaluation of an eye-pointer interaction device for human-computer interaction.

    PubMed

    Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián

    2018-03-01

    Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.

  13. Eye-Directed Overpressure Airwave-Induced Trauma Causes Lasting Damage to the Anterior and Posterior Globe: A Model for Testing Cell-Based Therapies

    PubMed Central

    Bricker-Anthony, Courtney; Hines-Beard, Jessica

    2016-01-01

    Abstract Purpose: Characterization of the response of the Balb/c mouse to an eye-directed overpressure airwave, with the hypothesis that this mouse strain and model is useful for testing potential therapeutics for the treatment of traumatic eye injury. Methods: The left eyes of adult Balb/c mice were exposed to an eye-directed overpressure airwave. Intraocular pressure (IOP) was measured and eyes were inspected for gross pathology changes. Optical coherence tomography and histology were used to examine the structural integrity of the retina and optic nerve. Immunohistochemistry, in vivo molecular fluorophores, and a multiplex enzyme-linked immunosorbent assay were utilized to identify changes in cell death, neuroinflammation, and oxidative stress. Results: This model induced a transient increase in IOP, corneal injuries, infrequent large retinal detachments, retinal pigment epithelium (RPE) vacuolization, glial reactivity, and retinal cell death. Both the corneal damage and RPE vacuolization persisted with time. Optic nerve degeneration occurred as early as 7 days postinjury and persisted out to 60 days. Retinal cell death, increased levels of reactive oxygen species, and neuroinflammation were detected at 7 days postinjury. Conclusions: The injury profile of the Balb/c mouse is consistent with commonly observed pathologies in blast-exposed patients. The damage is throughout the eye and persistent, making this mouse model useful for testing cell-based therapies. PMID:26982447

  14. Benefit of bi-ocular visual stimulation for postural control in children with strabismus.

    PubMed

    Gaertner, Chrystal; Creux, Charlotte; Espinasse-Berrod, Marie-Andrée; Orssaud, Christophe; Dufier, Jean-Louis; Kapoula, Zoï

    2013-01-01

    Vision is important for postural control as is shown by the Romberg quotient (RQ): with eyes closed, postural instability increases relative to eyes open (RQ = 2). Yet while fixating at far distance, postural stability is similar with eyes open and eyes closed (RQ = 1). Postural stability can be better with both eyes viewing than one eye, but such effect is not consistent among healthy subjects. The first goal of the study is to test the RQ as a function of distance for children with convergent versus divergent strabismus. The second goal is to test whether vision from two eyes relative to vision from one eye provides better postural stability. Thirteen children with divergent strabismus and eleven with convergent strabismus participated in this study. Posturtography was done with the Techno concept device. Experiment 1, four conditions: fixation at 40 cm and at 200 cm both with eyes open and eyes covered (evaluation of RQ). Experiment 2, six conditions: fixation at 40 cm and at 200 cm, with both eyes viewing or under monocular vision (dominant and non-dominant eye). For convergent strabismus, the groups mean value of RQ was 1.3 at near and 0.94 at far distance; for divergent, it was 1.06 at near and 1.68 at far. For all children, the surface of body sway was significantly smaller under both eyes viewing than monocular viewing (either eye). Increased RQ value at near for convergent and at far for divergent strabismus is attributed to the influence of the default strabismus angle and to better use of ocular motor signals. Vision with the two eyes improves postural control for both viewing distances and for both types of strabismus. Such benefit can be due to complementary mechanisms: larger visual field, better quality of fixation and vergence angle due to the use of visual inputs from both eyes.

  15. Effects of Punctal Occlusion on Clinical Signs and Symptoms and on Tear Cytokine Levels in Patients with Dry Eye.

    PubMed

    Tong, Louis; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E

    2016-04-01

    To investigate changes in signs, symptoms, and tear cytokines following punctal plug occlusion in patients with dry eye. A single-center study was conducted at Singapore Eye Research Institute. Nonabsorbable punctal plugs were inserted in the lower punctum of both eyes in patients with moderate dry eye. Over 3 weeks, in the more severe eye, dry eye symptoms, fluorescein corneal staining, Schirmer I (without topical anesthesia) test, tear film breakup time (TFBUT), and safety were assessed. Cytokine and matrix metalloproteinase-9 (MMP-9) levels in tear samples were measured. Twenty-nine patients (mean age 49.8 years) with moderate dry eye were evaluated. At baseline, mean (standard deviation) global symptoms score was 53.8 (26.5), Schirmer I test score was 5.1 (2.8) mm, and TFBUT was 2.2 (0.6) seconds. After 3 weeks, punctal occlusion significantly reduced global irritation symptoms score (P<.001) and decreased fluorescein staining in all zones (P<.01) except the inferior zone (P=.42). No significant association between levels of cytokines or MMP-9 and either TFBUT or global irritation symptoms were observed at baseline. Levels of several cytokines and MMP-9 were higher in patients with Schirmer I test scores ≤8 mm at baseline. After 3 weeks of punctal occlusion, no significant changes in overall cytokine or MMP-9 levels were observed. Punctal plug occlusion provided symptomatic relief and reduced fluorescein staining in all except the inferior zone. However, insertion of punctal plugs had minimal effect on tear cytokines and MMP-9 levels, suggesting a need for earlier treatment with anti-inflammatory agents for management of dry eye disease. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Determination of Risk Factors and Treatment of Dry Eye Disease in Type 1 Diabetes Before Corneal Complications at Sindh Institute of Ophthalmology And Visual Sciences.

    PubMed

    Shujaat, Shehnilla; Jawed, Muhammad; Memon, Shahzad; Talpur, Khalid Iqbal

    2017-01-01

    The objective of this study was to assess and determine the risk factors and treatment of dry eye disease in type 1 diabetes before any ocular surface or corneal complication occurs. This study was conducted at Sindh Institute of Ophthalmology And Visual Sciences, Hyderabad, Pakistan. Subjects and methods for observational study were undertaken at the Department of Ophthalmology Sindh Institute Of Ophthalmology And Visual Sciences, Hyderabad, Pakistan. Hundred confirmed cases of type 1 diabetes were included in the study by non probability convenience sampling. Tear film breakup time and schrimer test were carried out to determine dry eye disease. Data was collected by self-prepared questionnaire and entered and analyzed by using Statistical Program for Social Sciences (SPSS, version 20.0). The frequencies and percentage were recorded and any associations with predisposing factors were statistically analyzed by t test. Out of hundred patients, 71 (71%) were found to have dry eyes (P<0.001). The mean age of the subject in this study was 50.97 years (range 30-70 years). Old age was related to high risk of dry eye disease (P<0.001). There was no big difference in the incidence of dry eyes in males and females. Long duration was found to be related with increased occurrence of dry eyes (P<0.001). We found higher values for abnormal tear film break up time than schirmer test values leading to increased occurrence of evaporative dry eyes. There is marked increase in frequency/ risk of developing dry eye disease in type 1 diabetes patients. Therefore, it is recommended to have periodic ophthalmic examination for type 1 diabetic patients.

  17. Analysis of novel Sjogren's syndrome autoantibodies in patients with dry eyes.

    PubMed

    Everett, Sandra; Vishwanath, Sahana; Cavero, Vanessa; Shen, Long; Suresh, Lakshmanan; Malyavantham, Kishore; Lincoff-Cohen, Norah; Ambrus, Julian L

    2017-03-07

    Dry eye is a common problem in Ophthalmology and may occur for many reasons including Sjogren's syndrome (SS). Recent studies have identified autoantibodies, anti-salivary gland protein 1 (SP1), anti-carbonic anhydrase 6 (CA6) and anti-parotid secretory protein (PSP), which occur early in the course of SS. The current studies were designed to evaluate how many patients with idiopathic dry eye and no evidence of systemic diseases from a dry eye practice have these autoantibodies. Patients from a dry eye clinic and normal controls were assessed by Schirmer's test for tear flow. Sera were assessed for autoantibodies using ELISA assays. Statistics was performed with Prism 7 software and student's unpaired t test. In this study 60% of the dry eye patients expressed one of these autoantibodies. Only 30% expressed one of the autoantibodies associated with long-standing SS, which are included in the diagnostic criteria for SS, anti-Ro and anti-La. Patients with disease for less than 2 years and mild dry eyes did not express anti-Ro or anti-La, while 25% expressed anti-SP1. Similar observations, with smaller numbers, were made when patients had not only dry eye but also dry mouth. Antibodies to SP1, CA6 and PSP occur in some patients with idiopathic dry eyes. Further studies will be needed to determine how many of these patients go on to develop systemic manifestations of SS. Testing for these autoantibodies may allow early recognition of patients with SS. This will lead to improved management of the patients and the development of new strategies to maintain normal lacrimal and salivary gland function in patients with SS.

  18. Impact of oral vitamin D supplementation on the ocular surface in people with dry eye and/or low serum vitamin D.

    PubMed

    Yang, Chih-Huang; Albietz, Julie; Harkin, Damien G; Kimlin, Michael G; Schmid, Katrina L

    2018-02-01

    To determine the possible association between serum vitamin D levels and dry eye symptoms, and the impact of an oral vitamin D supplement. Three linked studies were performed. (i) 29 older adult participants, (ii) 29 dry eyed participants, and (iii) 2-month vitamin D supplementation for 32 dry eyed/low serum vitamin D levelled participants. All participants were assessed by the Ocular Surface Diseases Index (OSDI) to determine dry eye symptoms, and the phenol red thread test (PRT) and/or Schirmer's tear test, tear meniscus height, non-invasive tear break up time, grading ocular surface redness and fluorescein staining of the cornea to detect the tear quality and ocular surface conditions. Blood samples were collected for serum vitamin D analysis and interleukin-6 (IL-6) levels. Among older adult participants, vitamin D levels were negatively correlated with dry eye symptoms, the severity of dry eye, and associated with tired eye symptom. Vitamin D levels of people with dry eye diagnosis were not correlated with OSDI scores and IL-6 levels; while IL-6 levels showed correlation with tear production. In supplement study, vitamin D levels increased by 29mol/l, while dry eye symptoms and grading of corneal staining appeared significant reductions. No significant changes in IL-6 levels. Low vitamin D levels (<50nmol/l) were associated with dry eye symptoms in older individuals but not those diagnosed with dry eye. Vitamin D supplement increased the vitamin D levels, and improved dry eye symptoms, the tear quality and ocular surface conditions. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Knowledge and attitude of guardians towards eye health of primary school pupils in Ilorin, Nigeria.

    PubMed

    Ayanniyi, A A; Olatunji, F O; Mahmoud, A O; Ayanniyi, R O

    2010-03-01

    To determine guardians' knowledge and attitude towards pupils' eye health and draw implication for designing children-oriented ocular health messages. A survey of 1,393 guardians selected through multistage random sampling in Ilorin, Nigeria. Using structured questionnaire, information sought included guardians' demographic characteristics, relationship to pupils, occupation, awareness of eye specialists, perception of normal vision, pupils' eye complaints, and ways of treating children eye conditions. Data analysis was done with SPSS 12.0.1. The test of significance was performed using Chi square test and significance was taken at p < 0.05. Guardians comprised 689 (49.4%) males and 704 (50.6%) females, mean age 43.61 SD 11.45. Most (88.54%) were pupils' parents and (11.46%) were relations (n=1,318); (55.15%) were in low-paying occupations (n=1,311); (87.92%) were aware of eye specialists, (12.08%) unaware, (n=1192); (97.27%) adjudged normal vision at least important, (2.73%) not important (n=1,174). Pupils' eye complaints (n=914) included pain (26.04%), itching (24.73%), redness (21.12%), discharge (8.53%), blur vision (8.21%), photophobia (7.33%) and lacrimation (4.05%). Guardians (n=1,069) managed pupils' eye diseases using hospital treatment (61.65%), neglect (21.33%), self medication (9.26%) and traditional medication (7.76%). There were no significant associations between guardians' ways of managing pupils' eye diseases and their views on normal vision (p = 0.940); awareness of eye care specialists (p = 0.952); and economic occupational grouping (p = 0.959). The negative implications of neglecting eye diseases and use of self and harmful traditional eye-medications by some of the guardians need to be discouraged by appropriate eye health education.

  20. Monocular oral reading after treatment of dense congenital unilateral cataract

    PubMed Central

    Birch, Eileen E.; Cheng, Christina; Christina, V; Stager, David R.

    2010-01-01

    Background Good long-term visual acuity outcomes for children with dense congenital unilateral cataracts have been reported following early surgery and good compliance with postoperative amblyopia therapy. However, treated eyes rarely achieve normal visual acuity and there has been no formal evaluation of the utility of the treated eye for reading. Methods Eighteen children previously treated for dense congenital unilateral cataract were tested monocularly with the Gray Oral Reading Test, 4th edition (GORT-4) at 7 to 13 years of age using two passages for each eye, one at grade level and one at +1 above grade level. In addition, right eyes of 55 normal children age 7 to 13 served as a control group. The GORT-4 assesses reading rate, accuracy, fluency, and comprehension. Results Visual acuity of treated eyes ranged from 0.1 to 2.0 logMAR and of fellow eyes from −0.1 to 0.2 logMAR. Treated eyes scored significantly lower than fellow and normal control eyes on all scales at grade level and at +1 above grade level. Monocular reading rate, accuracy, fluency, and comprehension were correlated with visual acuity of treated eyes (rs = −0.575 to −0.875, p < 0.005). Treated eyes with 0.1-0.3 logMAR visual acuity did not differ from fellow or normal control eyes in rate, accuracy, fluency, or comprehension when reading at grade level or at +1 above grade level. Fellow eyes did not differ from normal controls on any reading scale. Conclusions Excellent visual acuity outcomes following treatment of dense congenital unilateral cataracts are associated with normal reading ability of the treated eye in school-age children. PMID:20603057

  1. Clinical Objective Dry Eye Tests in a Population of Tannery Workers in North India.

    PubMed

    Ranjan, Ratnesh; Kushwaha, Raj Nath; Khan, Perwez; Mohan, Shalini; Gupta, Ramesh Chandra

    2016-10-01

    To analyze the correlation between subjective symptoms and clinical signs of dry eye among tannery workers. In this cross-sectional study, three classic clinical tests, namely the fluorescein tear film break-up time (FTBUT) test, the fluorescein staining (FS) test, and the Schirmer test (ST), were performed to assess the clinical signs of dry eye disease in 246 tanners who were found symptomatic for dry eye in a prior ocular surface disease index survey. All workers were male with a mean age of 35 ± 9 years, and the mean duration of work at tanneries was 8 ± 5 years. Among 246 symptomatic subjects, the FTBUT test, the FS test and the ST were positive in 63.8%, 30.9% and 41.9% workers, respectively. Mean FTBUT and ST scores were 10.6 ± 4.2 seconds and 10.1 ± 7.7mm, respectively. Mean FTBUT for mild, moderate and severe symptom categories differed significantly. Mean ST scores for the mild symptom group were significantly higher than that of the moderate group (p < 0.0001). The FTBUT and ST score showed a strong negative correlation with severity of symptoms (p < 0.0001). A moderate positive correlation was observed between FS positivity and increasing symptom severity (p < 0.0001). The effect of age was insignificant for FTBUT (p = 0.10), while significant for ST score (p < 0.001). The effect of duration of tannery work was significant for both FTBUT and ST scores (p < 0.0001). Clinical tests correlated well with symptom severity among tanners, and a multifactorial etiology is suggested for dry eye diseases.

  2. Understanding disparities among diagnostic technologies in glaucoma.

    PubMed

    De Moraes, Carlos Gustavo V; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2012-07-01

    To investigate causes of disagreement among 3 glaucoma diagnostic techniques: standard automated achromatic perimetry (SAP), the multifocal visual evoked potential technique (mfVEP), and optical coherence tomography (OCT). In a prospective cross-sectional study, 138 eyes of 69 patients with glaucomatous optic neuropathy were tested using SAP, the mfVEP, and OCT. Eyes with the worse and better mean deviations (MDs) were analyzed separately. If the results of 2 tests were consistent for the presence of an abnormality in the same topographic site, that abnormality was considered a true glaucoma defect. If a third test missed that abnormality (false-negative result), the reasons for disparity were investigated. Eyes with worse MD (mean [SD], -6.8 [8.0] dB) had better agreements among tests than did eyes with better MD (-2.5 [3.5] dB, P<.01). For the 94 of 138 hemifields with abnormalities of the more advanced eyes, the 3 tests were consistent in showing the same hemifield abnormality in 50 hemifields (53%), and at least 2 tests were abnormal in 65 of the 94 hemifields (69%). The potential explanations for the false-negative results fell into 2 general categories: inherent limitations of each technique to detect distinct features of glaucoma and individual variability and the distribution of normative values used to define statistically significant abnormalities. All the cases of disparity could be explained by known limitations of each technique and interindividual variability, suggesting that the agreement among diagnostic tests may be better than summary statistics suggest and that disagreements between tests do not indicate discordance in the structure-function relationship.

  3. Early detection of glaucoma by means of a novel 3D computer‐automated visual field test

    PubMed Central

    Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald

    2007-01-01

    Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma. PMID:17504855

  4. Comparison of Ishihara Booklet with Color Vision Smartphone Applications.

    PubMed

    Sorkin, Nir; Rosenblatt, Amir; Cohen, Eyal; Ohana, Oded; Stolovitch, Chaim; Dotan, Gad

    2016-07-01

    To compare the standard Ishihara booklet with color-vision-testing smartphone applications. A prospective observational diagnostic study on 42 normal trichromats and 38 color-deficient subjects. Patients were presented with three color vision tests in random order: an Ishihara test booklet and two color-vision-testing smartphone applications: Eye2Phone and the Color Vision Test application (CVT app). Sensitivity and specificity of the electronic tests was compared with Ishihara results, and in each one of these applications every plate was individually analyzed for success/failure rate. Average age was 42.7 ± 12.9 years. There were 57 males (71.2%). Sensitivity and specificity of each test was 100% (38/38) and 95.2% (40/42) for the Eye2Phone, and 100% (38/38) and 54.8% (23/42) for the CVT app. There was no significant difference between the Ishihara booklet and the Eye2Phone (p = 0.500), with a high kappa measure of agreement (0.950, p < 0.001). The CVT app was significantly different than both other tests (p < 0.001) with a low kappa measure of agreement (0.535 with the Ishihara and 0.575 with the Eye2Phone). Of the 21 tested plates, color-deficient subjects failed 11.8 ± 3.1 plates in the Ishihara booklet and 14.1 ± 2.1 plates in the Eye2Phone (p < 0.001). Significant plate-specific differences for the color-deficient group were found in plate numbers 3, 6, 7, 8, 9, 15, and 16. Both tests were poorly able to give an indication of the specific dichromatism type. The Ishihara booklet was rated more comfortable and clearer than the Eye2Phone in color-deficient subjects. The CVT app was rated lowest for comfort and clarity in both groups. Smartphone applications testing for color vision deficiency are readily available; however, users of these apps should be aware that some may have different sensitivity for detection of color vision deficiency compared to Ishihara booklet, limiting their usefulness for clinical use. Therefore, further validation of these applications is required.

  5. Integrated Eye Tracking and Neural Monitoring for Enhanced Assessment of Mild TBI

    DTIC Science & Technology

    2016-04-01

    and we anticipate the initiation of the neuroimaging portion of the study early in Year 3. The fMRI task has been completed and is in beta testing...neurocognitive test battery, and self-report measures of cognitive efficacy. We will also include functional magnetic resonance imagining ( fMRI ) and... fMRI and DTI will provide an objective basis for cross-validating the EEG and eye tracking system. Both the EEG and eye tracking data will be

  6. Using eye tracking to test for individual differences in attention to attractive faces

    PubMed Central

    Valuch, Christian; Pflüger, Lena S.; Wallner, Bernard; Laeng, Bruno; Ansorge, Ulrich

    2015-01-01

    We assessed individual differences in visual attention toward faces in relation to their attractiveness via saccadic reaction times. Motivated by the aim to understand individual differences in attention to faces, we tested three hypotheses: (a) Attractive faces hold or capture attention more effectively than less attractive faces; (b) men show a stronger bias toward attractive opposite-sex faces than women; and (c) blue-eyed men show a stronger bias toward blue-eyed than brown-eyed feminine faces. The latter test was included because prior research suggested a high effect size. Our data supported hypotheses (a) and (b) but not (c). By conducting separate tests for disengagement of attention and attention capture, we found that individual differences exist at distinct stages of attentional processing but these differences are of varying robustness and importance. In our conclusion, we also advocate the use of linear mixed effects models as the most appropriate statistical approach for studying inter-individual differences in visual attention with naturalistic stimuli. PMID:25698993

  7. Using eye tracking to test for individual differences in attention to attractive faces.

    PubMed

    Valuch, Christian; Pflüger, Lena S; Wallner, Bernard; Laeng, Bruno; Ansorge, Ulrich

    2015-01-01

    We assessed individual differences in visual attention toward faces in relation to their attractiveness via saccadic reaction times. Motivated by the aim to understand individual differences in attention to faces, we tested three hypotheses: (a) Attractive faces hold or capture attention more effectively than less attractive faces; (b) men show a stronger bias toward attractive opposite-sex faces than women; and (c) blue-eyed men show a stronger bias toward blue-eyed than brown-eyed feminine faces. The latter test was included because prior research suggested a high effect size. Our data supported hypotheses (a) and (b) but not (c). By conducting separate tests for disengagement of attention and attention capture, we found that individual differences exist at distinct stages of attentional processing but these differences are of varying robustness and importance. In our conclusion, we also advocate the use of linear mixed effects models as the most appropriate statistical approach for studying inter-individual differences in visual attention with naturalistic stimuli.

  8. FogEye UV Sensor System : Low Visibility Landing Test (Phase IV Report)

    DOT National Transportation Integrated Search

    2004-03-01

    The potential of FogEye solar blind UV technology to contribute to safe and swift throughput operations at airports has been demonstrated. One application, use of FogEye (Safety Sentry), as an aircraft surface detection sensor has been successfully o...

  9. What can eye movements tell us about Symbol Digit substitution by patients with schizophrenia?

    PubMed

    Elahipanah, Ava; Christensen, Bruce K; Reingold, Eyal M

    2011-04-01

    Substitution tests are sensitive to cognitive impairment and reliably discriminate patients with schizophrenia from healthy individuals better than most other neuropsychological instruments. However, due to their multifaceted nature, substitution test scores cannot pinpoint the specific cognitive deficits that lead to poor performance. The current study investigated eye movements during performance on a substitution test in order to better understand what aspect of substitution test performance underlies schizophrenia-related impairment. Twenty-five patients with schizophrenia and 25 healthy individuals performed a computerized version of the Symbol Digit Modalities Test while their eye movements were monitored. As expected, patients achieved lower overall performance scores. Moreover, analysis of participants' eye movements revealed that patients spent more time searching for the target symbol every time they visited the key area. Patients also made more visits to the key area for each response that they made. Regression analysis suggested that patients' impaired performance on substitution tasks is primarily related to a less efficient visual search and, secondarily, to impaired memory. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Evaluating a Tablet Application and Differential Reinforcement to Increase Eye Contact in Children with Autism

    ERIC Educational Resources Information Center

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-01-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a…

  11. In vitro and in vivo topical delivery studies of tretinoin-loaded ultradeformable vesicles.

    PubMed

    Ascenso, Andreia; Salgado, Ana; Euletério, Carla; Praça, Fabíola Garcia; Bentley, Maria Vitória Lopes Badra; Marques, Helena C; Oliveira, Helena; Santos, Conceição; Simões, Sandra

    2014-09-01

    Ultradeformable vesicles are highly promising tools to enhance the percutaneous transport of different drugs such as tretinoin across the skin barrier and also to increase the formulation stability at absorption site and reduce the drug induced irritation. Topical delivery of tretinoin-loaded ultradeformable vesicles (tretinoin-UDV) was evaluated concerning different studies, such as: the release and permeation profiles (tape stripping); skin penetration (fluorescence analysis); induced electrical changes in skin barrier properties; cytotoxicity (Trypan Blue assay) and skin irritation in in vivo conditions (Draize test). The novel formulation performance was also compared to a commercial tretinoin formulation regarding in vivo studies. It was obtained a sustained and controlled drug release, as expected for UDV formulation. In addition, a dermal delivery was observed regarding the permeation study since it was not detected any drug amount in the receptor phase after 24h. Nile Red-UDV stained intensively mostly in the stratum corneum, corroborating the tape stripping results. Tretinoin-UDV decreased skin resistance, suggesting its ability to induce skin barrier disruption. Finally, the formulation vehicle (empty UDV) and tretinoin-UDV were not toxic under in vitro and in vivo conditions, at least, at 5×10(-3)mg/mL and 0.5mg/mL of tretinoin, respectively. Tretinoin-UDV is a promising delivery system for tretinoin dermal delivery without promoting skin irritation (unlike other commercial formulations), which is quite advantageous for therapeutic purpose. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Nano vesicular lipid carriers of angiotensin II receptor blocker: Anti-hypertensive and skin toxicity study in focus.

    PubMed

    Ahad, Abdul; Aqil, Mohd; Kohli, Kanchan; Sultana, Yasmin; Mujeeb, Mohd

    2016-05-01

    Nanoethosomal carriers of valsartan have been previously prepared, characterized and optimized. A gel formulation of valsartan vesicular lipid carriers was composed of Carbopol(®) (1% w/w), polyethylene glycol-400 (15% w/w) and triethanolamine (0.5% w/w). The influence of the valsartan nanoethosomal formulation developed on the blood pressure of experimental hypertensive rats, and its potential for skin irritation, are presented in this report. The experimental rats were divided into three groups; the control group received no treatment (Group A). Group B was administered methyl prednisolone acetate (20 mg/kg/week) for two weeks (hypertensive control). Group C received methyl prednisolone acetate, followed by administration of the valsartan ethosomal formulation. The blood pressure of the rats was measured using a non-invasive rat blood pressure instrument based on the tail-cuff technique. The statistical analysis was performed using GraphPad InStat 3 software. The treatment group showed a significant (P < 0.05) and constant fall in blood pressure, for up to 48 h. The valsartan ethosomal formulation was found to be effective, with a 34.11% reduction in blood pressure. The formulation's potential for skin irritation was assessed by the Draize irritation score test, which ruled out the possibility of any skin irritation caused by application of the formulation in rats. Our results suggest that nanoethosomes are efficient carriers for transdermal delivery of valsartan, for the management of hypertension.

  13. Effects of Lycopersicon esculentum extract on hair growth and alopecia prevention.

    PubMed

    Choi, Jae-Suk; Jung, Sung Kyu; Jeon, Min-Hee; Moon, Jin-Nam; Moon, Woi-Sook; Ji, Yi-Hwa; Choi, In Soon; Wook Son, Sang

    2013-01-01

    To evaluate the potential hair growth-promoting activity and the expression of cell growth factors of Lycopersicon esculentum extracts, each 3% (w/w) of ethyl acetate extract (EAE), and supercritical CO2 extract (SCE) of L. esculentum and isolated lycopene Tween 80 solution (LTS) and test hair tonic (THT) containing LTS were applied on the dorsal skin of C57BL/6 mice, once a day for 4 weeks. At week 4, LTS and THT exhibited hair growth-promoting potential similar to that of 3% minoxidil as a positive control (PC). Further, in the LTS group, a significant increase of mRNA expression of vascular endothelial growth factor (VEGF), keratinocyte growth factor, and insulin-like growth factor-1 (IGF-1) was observed than PC, as well as the negative control (NC). In the THT group, increases in IGF-1 and decrease in VEGF and transforming growth factor-β expression were significant over the NC. In a histological examination in the THT group, the induction of anagen stage of hair follicles was faster than that of NC. In the Draize skin irritation study for THT, no observable edema or erythema was observed on all four sectors in the back skin after exposure for 24 or 72 h for any rabbit. Therefore, this study provides reasonable evidence that L. esculentum extracts promote hair growth and suggests that applications could be found in hair loss treatments without skin irritation at moderate doses.

  14. The "Reading the Mind in the Eyes" Test: Investigation of Psychometric Properties and Test-Retest Reliability of the Persian Version

    ERIC Educational Resources Information Center

    Khorashad, Behzad S.; Baron-Cohen, Simon; Roshan, Ghasem M.; Kazemian, Mojtaba; Khazai, Ladan; Aghili, Zahra; Talaei, Ali; Afkhamizadeh, Mozhgan

    2015-01-01

    The psychometric properties of the Persian "Reading the Mind in the Eyes" test were investigated, so were the predictions from the Empathizing-Systemizing theory of psychological sex differences. Adults aged 16-69 years old (N = 545, female = 51.7%) completed the test online. The analysis of items showed them to be generally acceptable.…

  15. Instability of ocular torsion in zero gravity - Possible implications for space motion sickness

    NASA Technical Reports Server (NTRS)

    Diamond, Shirley G.; Markham, Charles H.; Money, Ken E.

    1990-01-01

    It is proposed that study of the eye torsion reflex and its behavior under novel gravitational states may possibly provide the basis for a long-sought test to predict space motion sickness (SMS). Measures of eye torsion such as ocular counterrolling and spontaneous eye torsion, were examined during hypo- and hypergravity in parabolic flight on the NASA KC-135 aircraft. Ten subjects, including two astronauts, one who had experienced SMS and one who had not, were ranked according to scores of torsional inability at 0 G and divided into two equal groups of high and low susceptibility to SMS. At 1.8 G the groups were significantly different in both the instability measure and the measure of torsional ability. No differences were detected in eye torsion in either 0 G or 1.8 G and none of the tests were significantly different in 1 G. Results suggest that tests of eye torsion on the KC-135 might differentiate those who would experience SMS from those who would not, although it is noted that this is not yet proven.

  16. Eye Movement Indices in the Study of Depressive Disorder

    PubMed Central

    LI, Yu; XU, Yangyang; XIA, Mengqing; ZHANG, Tianhong; WANG, Junjie; LIU, Xu; HE, Yongguang; WANG, Jijun

    2016-01-01

    Background Impaired cognition is one of the most common core symptoms of depressive disorder. Eye movement testing mainly reflects patients’ cognitive functions, such as cognition, memory, attention, recognition, and recall. This type of testing has great potential to improve theories related to cognitive functioning in depressive episodes as well as potential in its clinical application. Aims This study investigated whether eye movement indices of patients with unmedicated depressive disorder were abnormal or not, as well as the relationship between these indices and mental symptoms. Methods Sixty patients with depressive disorder and sixty healthy controls (who were matched by gender, age and years of education) were recruited, and completed eye movement tests including three tasks: fixation task, saccade task and free-view task. The EyeLink desktop eye tracking system was employed to collect eye movement information, and analyze the eye movement indices of the three tasks between the two groups. Results (1) In the fixation task, compared to healthy controls, patients with depressive disorder showed more fixations, shorter fixation durations, more saccades and longer saccadic lengths; (2) In the saccade task, patients with depressive disorder showed longer anti-saccade latencies and smaller anti-saccade peak velocities; (3) In the free-view task, patients with depressive disorder showed fewer saccades and longer mean fixation durations; (4) Correlation analysis showed that there was a negative correlation between the pro-saccade amplitude and anxiety symptoms, and a positive correlation between the anti-saccade latency and anxiety symptoms. The depression symptoms were negatively correlated with fixation times, saccades, and saccadic paths respectively in the free-view task; while the mean fixation duration and depression symptoms showed a positive correlation. Conclusion Compared to healthy controls, patients with depressive disorder showed significantly abnormal eye movement indices. In addition patients’ anxiety and depression symptoms and eye movement indices were correlated. The pathological meaning of these phenomena deserve further exploration. PMID:28638208

  17. Eye Movement Indices in the Study of Depressive Disorder.

    PubMed

    Li, Yu; Xu, Yangyang; Xia, Mengqing; Zhang, Tianhong; Wang, Junjie; Liu, Xu; He, Yongguang; Wang, Jijun

    2016-12-25

    Impaired cognition is one of the most common core symptoms of depressive disorder. Eye movement testing mainly reflects patients' cognitive functions, such as cognition, memory, attention, recognition, and recall. This type of testing has great potential to improve theories related to cognitive functioning in depressive episodes as well as potential in its clinical application. This study investigated whether eye movement indices of patients with unmedicated depressive disorder were abnormal or not, as well as the relationship between these indices and mental symptoms. Sixty patients with depressive disorder and sixty healthy controls (who were matched by gender, age and years of education) were recruited, and completed eye movement tests including three tasks: fixation task, saccade task and free-view task. The EyeLink desktop eye tracking system was employed to collect eye movement information, and analyze the eye movement indices of the three tasks between the two groups. (1) In the fixation task, compared to healthy controls, patients with depressive disorder showed more fixations, shorter fixation durations, more saccades and longer saccadic lengths; (2) In the saccade task, patients with depressive disorder showed longer anti-saccade latencies and smaller anti-saccade peak velocities; (3) In the free-view task, patients with depressive disorder showed fewer saccades and longer mean fixation durations; (4) Correlation analysis showed that there was a negative correlation between the pro-saccade amplitude and anxiety symptoms, and a positive correlation between the anti-saccade latency and anxiety symptoms. The depression symptoms were negatively correlated with fixation times, saccades, and saccadic paths respectively in the free-view task; while the mean fixation duration and depression symptoms showed a positive correlation. Compared to healthy controls, patients with depressive disorder showed significantly abnormal eye movement indices. In addition patients' anxiety and depression symptoms and eye movement indices were correlated. The pathological meaning of these phenomena deserve further exploration.

  18. Differentiation between Vergence and Saccadic Functional Activity within the Human Frontal Eye Fields and Midbrain Revealed through fMRI

    PubMed Central

    Alkan, Yelda; Biswal, Bharat B.; Alvarez, Tara L.

    2011-01-01

    Purpose Eye movement research has traditionally studied solely saccade and/or vergence eye movements by isolating these systems within a laboratory setting. While the neural correlates of saccadic eye movements are established, few studies have quantified the functional activity of vergence eye movements using fMRI. This study mapped the neural substrates of vergence eye movements and compared them to saccades to elucidate the spatial commonality and differentiation between these systems. Methodology The stimulus was presented in a block design where the ‘off’ stimulus was a sustained fixation and the ‘on’ stimulus was random vergence or saccadic eye movements. Data were collected with a 3T scanner. A general linear model (GLM) was used in conjunction with cluster size to determine significantly active regions. A paired t-test of the GLM beta weight coefficients was computed between the saccade and vergence functional activities to test the hypothesis that vergence and saccadic stimulation would have spatial differentiation in addition to shared neural substrates. Results Segregated functional activation was observed within the frontal eye fields where a portion of the functional activity from the vergence task was located anterior to the saccadic functional activity (z>2.3; p<0.03). An area within the midbrain was significantly correlated with the experimental design for the vergence but not the saccade data set. Similar functional activation was observed within the following regions of interest: the supplementary eye field, dorsolateral prefrontal cortex, ventral lateral prefrontal cortex, lateral intraparietal area, cuneus, precuneus, anterior and posterior cingulates, and cerebellar vermis. The functional activity from these regions was not different between the vergence and saccade data sets assessed by analyzing the beta weights of the paired t-test (p>0.2). Conclusion Functional MRI can elucidate the differences between the vergence and saccade neural substrates within the frontal eye fields and midbrain. PMID:22073141

  19. Looking at a predator with the left or right eye: asymmetry of response in lizards.

    PubMed

    Bonati, Beatrice; Csermely, Davide; Sovrano, Valeria Anna

    2013-01-01

    Studies carried out with the common wall lizard (Podarcis muralis) revealed preferential use of the left eye during responses to predatory threat in laboratory settings and in the wild. Here we tested lizards under monocular conditions of vision, using temporary eye-patching. Lizards were facing a (simulated) predatory threat laterally, from the side of the non-patched eye. Results showed that lizards with the left eye uncovered during predatory threat used the left eye to monitor the predator, whereas lizards with the right eye uncovered nonetheless tried to use the covered left eye. Moreover, lizards frequently tried to change the eye exposition, making a body C-bend behaviour. Right-eyed lizards showed more frequent and faster C-bending responses than left-eyed lizards, trying to monitor the predator with the left eye even though it was patched. Results fit with asymmetries in spontaneous eye use observed in laboratory conditions and in the wild in this species, confirming that structures located on the right side of the brain (mainly served by the left eye) predominantly attend to predatory threat.

  20. Standing balance tests for screening people with vestibular impairments.

    PubMed

    Cohen, Helen S; Mulavara, Ajitkumar P; Peters, Brian T; Sangi-Haghpeykar, Haleh; Bloomberg, Jacob J

    2014-02-01

    To improve the test standards for a version of the Romberg test and to determine whether measuring kinematic variables improved its utility for screening. Healthy controls and patients with benign paroxysmal positional vertigo, postoperative acoustic neuroma resection, and chronic peripheral unilateral weakness were compared. Subjects wore Bluetooth-enabled inertial motion units while standing on the floor or medium-density, compliant foam, with eyes open or closed, with head still or moving in pitch or yaw. Dependent measures were time to perform each test condition, number of head movements made, and kinematic variables. Patients and controls did not differ significantly with eyes open or with eyes closed while on the floor. With eyes closed, on foam, some significant differences were found between patients and controls, especially for subjects older than 59 years. Head movement conditions were more challenging than with the head still. Significantly fewer patients than controls could make enough head movements to obtain kinematic measures. Kinematics indicated that lateral balance control is significantly reduced in these patients compared to controls. Receiver operator characteristics and sensitivity/specificity analyses showed moderately good differences with older subjects. Tests on foam with eyes closed, with head still or moving, may be useful as part of a screening battery for vestibular impairments, especially for older people. 3b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  1. Impact of lifestyle intervention on dry eye disease in office workers: a randomized controlled trial.

    PubMed

    Kawashima, Motoko; Sano, Kokoro; Takechi, Sayuri; Tsubota, Kazuo

    2018-04-04

    To evaluate the effects of a 2-month lifestyle intervention for dry eye disease in office workers. Prospective interventional study (randomized controlled study). Forty-one middle-aged Japanese office workers (men, 22; women, 19; 39.2 ± 8.0 years) with definite and probable dry eye disease were enrolled and randomized to an intervention group (n = 22) and a control group (n = 19). The intervention aimed at modifying diet, increasing physical activity, and encouraging positive thinking. The primary outcome was change in dry eye disease diagnoses. Secondary outcome was change in disease parameters, including dry eye symptoms, as assessed using the Dry Eye-Related Quality of Life Score, corneal and conjunctival staining scores, tear break-up time, and Schirmer test results. A total of 36 participants (intervention group, 17; control group, 19) completed the study. The number of definite dry eye disease diagnoses decreased from four to none (p =.05), and the dry eye symptom score showed a significant decrease in the intervention group (p =.03). In contrast, the corneal and conjunctival staining scores, tear break-up time, and Schirmer test results did not differ significantly between groups. The 2-month lifestyle intervention employed in this study improved dry eye disease status among office workers, with a considerable decrease in subjective symptoms. Lifestyle intervention may be a promising management option for dry eye disease, although further investigation of long-term effects are required.

  2. [Eye symptoms in office employees working at computer stations].

    PubMed

    Kowalska, Małgorzata; Zejda, Jan E; Bugajska, Joanna; Braczkowska, Bogumiła; Brozek, Grzegorz; Malińska, Marzena

    2011-01-01

    The aim of the study was to measure the prevalence and intensity of eye symptoms in office workers who use computers on a regular basis, and to find out if the symptoms depend on the duration of computer use and other work-related factors. Office workers employed at large social services companies in two cities (Warszawa and Katowice) were invited to fill in a questionnaire (cross-sectional study). The questions included work history and history of last-week eye symptoms and eye-related complains. Altogether 477 men and women returned the completed questionnaires. Between-group symptom differences were tested by the chi-square test and verified by the results of multivariate logistic analysis. The examined effects included the role of daily computer use and lighting conditions at work stations. The examined persons complained of such eye symptoms as eye strain, visual acuity impairment and mucosal dryness or eye burning. The following values of symptom prevalence were found in women and men, respectively: eye strain 50.7% and 32.6%, disturbed visual acuity 38.3% and 21.2%, mucosal dryness and eye burning 46.5% and 24.2%. The results of multivariate analysis confirmed the statistically significant effects of lighting intensity and screen flickering on the occurrence of symptoms. Frequent occurrence of eye symptoms and their associatation with some characteristics of the work environment point to the need of observing ergonomic standards of work stations and of the usage of computers at work.

  3. Normative values for the unipedal stance test with eyes open and closed.

    PubMed

    Springer, Barbara A; Marin, Raul; Cyhan, Tamara; Roberts, Holly; Gill, Norman W

    2007-01-01

    Limited normative data are available for the unipedal stance test (UPST), making it difficult for clinicians to use it confidently to detect subtle balance impairments. The purpose of this study was to generate normative values for repeated trials of the UPST with eyes opened and eyes closed across age groups and gender. This prospective, mixed-model design was set in a tertiary care medical center. Healthy subjects (n= 549), 18 years or older, performed the UPST with eyes open and closed. Mean and best of 3 UPST times for males and females of 6 age groups (18-39, 40-49, 50-59, 60-69, 70-79, and 80+) were documented and inter-rater reliability was tested. There was a significant age dependent decrease in UPST time during both conditions. Inter-rater reliability for the best of 3 trials was determined to be excellent with an intra-class correlation coefficient of 0.994 (95% confidence interval 0.989-0.996) for eyes open and 0.998 (95% confidence interval 0.996-0.999) for eyes closed. This study adds to the understanding of typical performance on the UPST. Performance is age-specific and not related to gender. Clinicians now have more extensive normative values to which individuals can be compared.

  4. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    NASA Astrophysics Data System (ADS)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.

  5. Oral supplementation with a nutraceutical formulation containing omega-3 fatty acids, vitamins, minerals, and antioxidants in a large series of patients with dry eye symptoms: results of a prospective study.

    PubMed

    Gatell-Tortajada, Jordi

    2016-01-01

    To assess the benefits and tolerability of a dietary supplement based on omega-3 fatty acids to relieve dry eye symptoms. A total of 1,419 patients (74.3% women, mean age 58.9 years) with dry eye syndrome using artificial tears participated in a 12-week prospective study. Patients were instructed to take 3 capsules/day of the nutraceutical formulation (Brudysec(®) 1.5 g). Study variables were dry eye symptoms (scratchy and stinging sensation, eye redness, grittiness, painful and tired eyes, grating sensation, and blurry vision), conjunctival hyperemia, tear breakup time (TBUT), Schrimer I test, and Oxford grading scheme. At 12 weeks, each dry eye symptom improved significantly (P<0.001), and the use of artificial tears decreased significantly from 3.77 (standard deviation [SD] =2.08) at baseline to 3.45 (SD =1.72) (P<0.01). In addition, the Schirmer test scores and the TBUT increased significantly, and there was an increase in patients grading 0-I in the Oxford scale and a decrease of those grading IV-V. Significant differences in improvements of dry eye symptoms were also found in compliant versus noncompliant patients as well as in those with moderate/severe versus none/mild conjunctival hyperemia. Oral ω-3 fatty acids supplementation was an effective treatment for dry eye symptoms.

  6. Polypropylene vs silicone Ahmed valve with adjunctive mitomycin C in paediatric age group: a prospective controlled study

    PubMed Central

    El Sayed, Y; Awadein, A

    2013-01-01

    Purpose To compare the results of silicone and polypropylene Ahmed glaucoma valves (AGV) implanted during the first 10 years of life. Methods A prospective study was performed on 50 eyes of 33 patients with paediatric glaucoma. Eyes were matched to either polypropylene or silicone AGV. In eyes with bilateral glaucoma, one eye was implanted with polypropylene and the other eye was implanted with silicone AGV. Results Fifty eyes of 33 children were reviewed. Twenty five eyes received a polypropylene valve, and 25 eyes received a silicone valve. Eyes implanted with silicone valves achieved a significantly lower intraocular pressure (IOP) compared with the polypropylene group at 6 months, 1 year, and 2 years postoperatively. The average survival time was significantly longer (P=0.001 by the log-rank test) for the silicone group than for the polypropylene group and the cumulative probability of survival by the log-rank test at the end of the second year was 80% (SE: 8.0, 95% confidence interval (CI): 64–96%) in the silicone group and 56% (SE: 9.8, 95% CI: 40–90%) in the polypropylene group. The difference in the number of postoperative interventions and complications between both groups was statistically insignificant. Conclusion Silicone AGVs can achieve better IOP control, and longer survival with less antiglaucoma drops compared with polypropylene valves in children younger than 10 years. PMID:23579403

  7. Contrast masking in strabismic amblyopia: attenuation, noise, interocular suppression and binocular summation.

    PubMed

    Baker, Daniel H; Meese, Tim S; Hess, Robert F

    2008-07-01

    To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

  8. A Field Test of Web-Based Screening for Dry Eye Disease to Enhance Awareness of Eye Problems Among General Internet Users: A Latent Strategy to Promote Health

    PubMed Central

    Uchino, Miki; Kawazoe, Takashi; Kamiyashiki, Masaaki; Sano, Kokoro; Tsubota, Kazuo

    2013-01-01

    Background A Web-based self-check system including a brief questionnaire would seem to be a suitable tool for rapid disease screening. Objective The purpose of this preliminary study was to test a Web-based self-screening questionnaire for drawing attention to dry eye disease among general Internet users and identifying those with a higher risk of developing the condition. Methods A survey website was launched and used to recruit participants from general Internet users. In the first phase, volunteers were asked to complete a Web-based self-screening questionnaire containing 12 questions on dry eye symptoms. The second phase focused on the respondents who reported five or more dry eye symptoms and expressed their intention to seek medical attention. These participants performed the Schirmer test, for evaluating tear production, and completed a paper-based lifestyle questionnaire to provide relevant background data. Results Of the 1689 visitors to the website, 980 (58.0%) volunteers completed the Web-based self-screening questionnaire. Among these, 355 (36.2%) respondents reported five or more dry eye symptoms. Then, 99 (27.9%) of the symptomatic participants performed the Schirmer test and completed the paper-based lifestyle questionnaire. Out of these, 32 (32.2%) had abnormal tear production (≤5 mm). Conclusions The proposed Web-based self-screening questionnaire seems to be a promising tool for raising awareness of dry eye disease among general Internet users and identifying those with a higher risk of developing the condition, although further research is needed to validate its effectiveness. PMID:24072379

  9. Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.

    PubMed

    Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor

    2013-07-01

    To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.

  10. Diquafosol sodium ophthalmic solution for the treatment of dry eye: clinical evaluation and biochemical analysis of tear composition.

    PubMed

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Tsubota, Kazuo

    2015-11-01

    To evaluate the clinical efficacy of 3% diquafosol sodium ophthalmic solution for dry eye, and to analyze the concentration of tear proteins and mucin-like substances after the treatment. Fifty eyes of 25 patients with dry eye syndrome were prospectively enrolled. The patients were treated with diquafosol solution at a dose of 1 drop in each eye 6 times daily for 4 weeks. The parameters of clinical efficacy were tear osmolarity, tear breakup time (BUT), fluorescein staining scores for the cornea and conjunctiva, Schirmer test values, and subjective symptoms evaluated using the ocular surface disease index (OSDI). Tears collected with Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of the total protein and the 4 major tear proteins, namely, secretory IgA, lactoferrin, lipocalin-1, lysozyme, and N-acetyl-neuraminic acid (Neu5Ac), were measured. Neu5Ac is a major sialic acid, a marker of secretory mucins. The BUT, keratoconjunctival staining scores, and Schirmer test values were improved with statistical significance after the treatment with diquafosol solution, while changes in the other parameters, including tear osmolarity, corneal staining scores, and OSDI scores were not significant. The Neu5Ac concentration was significantly increased, which was not accompanied by changes in tear proteins. Topical application of diquafosol significantly improved the clinical parameters of the BUT, keratoconjunctival staining scores, and Schirmer test values and was accompanied by increased sialic acid content in the tears of patients with dry eye.

  11. Saccadic eye movement performance as an indicator of driving ability in elderly drivers.

    PubMed

    Schmitt, Kai-Uwe; Seeger, Rolf; Fischer, Hartmut; Lanz, Christian; Muser, Markus; Walz, Felix; Schwarz, Urs

    2015-01-01

    Regular checking of the fitness to drive of elderly car-license holders is required in some countries, and this will become increasingly important as more countries face aging populations. The present study investigated whether the analysis of saccadic eye movements could be used as a screening method for the assessment of driving ability. Three different paradigms (prosaccades, antisaccades, and visuovisual interactive (VVI) saccades) were used to test saccadic eye movements in 144 participants split into four groups: elderly drivers who came to the attention of road authorities for suspected lack of fitness to drive, a group of elderly drivers who served as a comparison group, a group of neurology patients with established brain lesion diagnoses, and a young comparison group. The group of elderly drivers with suspected deficits in driving skills also underwent a medical examination and a practical on-road driving test. The results of the saccadic eye tests of the different groups were compared. Antisaccade results indicated a strong link to driving behaviour: elderly drivers who were not fit to drive exhibited a poor performance on the antisaccade task and the performance in the VVI task was also clearly poorer in this group. Testing saccadic eye movements appears to be a promising and efficient method for screening large numbers of people such as elderly drivers. This study indicated a link between antisaccade performance and the ability to drive. Hence, measuring saccadic eye movements should be considered as a tool for screening the fitness to drive.

  12. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    PubMed

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p < 0.001). Subgroup analysis revealed (I) right eye laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  13. Efficacy of topical nerve growth factor treatment in dogs affected by dry eye.

    PubMed

    Coassin, Marco; Lambiase, Alessandro; Costa, Nicola; De Gregorio, Alessandra; Sgrulletta, Roberto; Sacchetti, Marta; Aloe, Luigi; Bonini, Stefano

    2005-02-01

    Preliminary data show that nerve growth factor (NGF) may improve tear production in humans. We evaluated the efficacy of topical NGF treatment in dogs who developed dry eye after the excision of the third eyelid lacrimal gland. English Bulldogs (2- to 6-year-old males and females) that had undergone the surgical removal of the prolapsed lacrimal gland of the third eyelid in both eyes at the age of 3-6 months developed chronic keratoconjunctivitis sicca associated with a decrease of Schirmer tear test I values after at least 1 year. One eye, randomly selected, of each dog was treated twice daily with 100 microl of NGF ointment for 1 month, while the fellow eye was used as control and treated with the ointment vehicle only. At baseline and after 1 month of NGF treatment the following examinations were performed: corneal evaluation by slit lamp, fluorescein staining, Schirmer tear test I, tear ferning test, corneal esthesiometry by cotton swab and conjunctival impression cytology. Topical application of NGF caused a significant improvement of all the evaluated parameters compared with baseline values. In contrast, in the control eyes there was no significant difference between the values measured before and after treatment. In particular, after NGF treatment superficial punctate keratopathy was resolved, corneal haze was reduced from stage 4 to stage 2 and Schirmer test values increased (17.2+/-1.7 mm/min vs 4.5+/-1.3 mm/min; p<0.05), as did the tear mucous component (as demonstrated by ferning test: 2.0+/-0.0 vs 4.0+/-0.0; p<0.05); conjunctival impression cytology evaluation demonstrated the presence of numerous mucous filaments and a significant increase in conjunctival goblet cell density (102.7+/-68.3 vs. 18.2+/-14.3 cell x field; p<0.05). Topical NGF treatment improved corneal sensitivity in two of three eyes. This open study suggests that topical application of NGF may enhance the production and functional characteristics in tear film, with an improvement of ocular surface signs in dogs with surgically induced dry eye. These results suggest the possibility of performing further, larger, controlled studies.

  14. Ultrathin flexible piezoelectric sensors for monitoring eye fatigue

    NASA Astrophysics Data System (ADS)

    Lü, Chaofeng; Wu, Shuang; Lu, Bingwei; Zhang, Yangyang; Du, Yangkun; Feng, Xue

    2018-02-01

    Eye fatigue is a symptom induced by long-term work of both eyes and brains. Without proper treatment, eye fatigue may incur serious problems. Current studies on detecting eye fatigue mainly focus on computer vision detect technology which can be very unreliable due to occasional bad visual conditions. As a solution, we proposed a wearable conformal in vivo eye fatigue monitoring sensor that contains an array of piezoelectric nanoribbons integrated on an ultrathin flexible substrate. By detecting strains on the skin of eyelid, the sensors may collect information about eye blinking, and, therefore, reveal human’s fatigue state. We first report the design and fabrication of the piezoelectric sensor and experimental characterization of voltage responses of the piezoelectric sensors. Under bending stress, the output voltage curves yield key information about the motion of human eyelid. We also develop a theoretical model to reveal the underlying mechanism of detecting eyelid motion. Both mechanical load test and in vivo test are conducted to convince the working performance of the sensors. With satisfied durability and high sensitivity, this sensor may efficiently detect abnormal eyelid motions, such as overlong closure, high blinking frequency, low closing speed and weak gazing strength, and may hopefully provide feedback for assessing eye fatigue in time so that unexpected situations can be prevented.

  15. [Can fixation disparity be detected reliably by measurement and correctional techniques according H.J. Haase (MKH)?].

    PubMed

    Gerling, J; de Paz, H; Schroth, V; Bach, M; Kommerell, G

    2000-06-01

    The theory of the "Measuring and Correction Methods of H.-J. Haase" (MCH) states that a small misalignment of one eye, called fixation disparity, indicates a difficulty in overcoming a "vergence position of rest" that is different from ortho position. This difficulty, so the theory, can cause asthenopic complaints, such as headaches, and these complaints can be relieved by prisms. The theory further claims that fixation disparity can be ascertained by a series of tests which depend on the subject's perception. The tests most decisive for the diagnosis of a so-called fixation disparity type 2 consist of stereo displays. The magnitude of the prism that allows the subject to see the test configurations in symmetry is thought to be the one that corrects the "vergence position of rest". Nine subjects with healthy eyes in whom a "fixation disparity type 2" had been diagnosed were selected for the study. Misalignment of the eyes was determined according to the principle of the unilateral cover test. Targets identical for both eyes were presented on the screen of the Polatest E. Then, the target was deleted for one eye and the ensuing position change of the other eye was measured, using the search coil technique. This test was performed both with and without the MCH prism. In all 9 subjects the misalignment was less than 10 minutes of arc, i.e. in the range of normal fixation instability. Averaging across the 9 subjects, the deviation of the eye (misaligned according to MCH) was 0.79 +/- 3.45 minutes of arc in the direction opposed to that predicted by the MCH, a value not significantly different from zero. The MCH prism elicited a fusional vergence movement the magnitude of which corresponded to the magnitude of the MCH prism. Ascertaining fixation disparity with the MCH is unreliable. Accordingly, it appears dubious to correct a "vergence position of rest" on the basis of the MCH.

  16. The Effect of Pseudoexfoliation and Pseudoexfoliation Induced Dry Eye on Central Corneal Thickness.

    PubMed

    Akdemir, M Orcun; Kirgiz, Ahmet; Ayar, Orhan; Kaldirim, Havva; Mert, Metin; Cabuk, Kubra Serefoglu; Taskapili, Muhittin

    2016-01-01

    The aim of this study is to investigate the effect of pseudoexfoliation (PEX) and PEX-induced dry eye on central corneal thickness (CCT). This cross-sectional study consists of total 270 eyes of 135 patients (67 females, 68 males) in total. After excluding the PEX (-) 32 eyes with PEX in the other eye, totally 130 eyes in PEX (-) group and 108 eyes in the PEX (+) group were included in the study. The PEX (+) group was regrouped as PEX syndrome (80 eyes of 50 patients) and PEX glaucoma (28 eyes of 20 patients). In the PEX (-) group, the mean Schirmer test result was 12 ± 4 mm (4-25 mm), in the PEX syndrome group 10 ± 4 mm (4-22 mm), in the PEX glaucoma group 9 ± 3 mm (4-15 mm). The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was statistically significant (p < 0.001, p < 0.001, respectively). In the PEX (-) group, the mean tear break up time test result was 11 ± 2 s (5-16 s), in the PEX syndrome group 8 ± 3 (3-16 s), in the PEX glaucoma group 8 ± 3 s (5-15 s). Mean CCT result was 544 µm in the PEX (-), 521 µm in the PEX syndrome group and 533 µm in the PEX glaucoma group. The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was significant (p < 0.001, p = 0.030, respectively). There was a significant (+) correlation between intraocular pressure and CCT in the eyes with PEX (r = 0.307, p = 0.001). However, there was no statistically significant correlation between CCT, Schirmer and tear break up time tests in the eyes with PEX. PEX material can cause decrease in tear film secretion and disturb tear film stability. There is no effect of PEX-induced dry eye on CCT. Lower CCT values in the eyes with PEX material may be a result of decrease in corneal stromal cell density. Moreover, higher CCT values may be because of decreased endothelial cells in PEX glaucoma patients.

  17. The Cost of Being Watched: Stroop Interference Increases under Concomitant Eye Contact

    ERIC Educational Resources Information Center

    Conty, Laurence; Gimmig, David; Belletier, Clement; George, Nathalie; Huguet, Pascal

    2010-01-01

    Current models in social neuroscience advance that eye contact may automatically recruit cognitive resources. Here, we directly tested this hypothesis by evaluating the distracting strength of eye contact on concurrent visual processing in the well-known Stroop's paradigm. As expected, participants showed stronger Stroop interference under…

  18. Horizontal Saccadic Eye Movements Enhance the Retrieval of Landmark Shape and Location Information

    ERIC Educational Resources Information Center

    Brunye, Tad T.; Mahoney, Caroline R.; Augustyn, Jason S.; Taylor, Holly A.

    2009-01-01

    Recent work has demonstrated that horizontal saccadic eye movements enhance verbal episodic memory retrieval, particularly in strongly right-handed individuals. The present experiments test three primary assumptions derived from this research. First, horizontal eye movements should facilitate episodic memory for both verbal and non-verbal…

  19. Intraocular (Uveal) Melanoma Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Cancer.gov

    Intraocular melanoma is a rare cancer that forms from cells that make melanin in the eye. It is the most common eye cancer in adults and may not cause early signs or symptoms. Find out risk factors, tests to diagnose, prognosis, and staging for intraocular melanoma.

  20. Needed: Instruments as Good as Our Eyes

    ERIC Educational Resources Information Center

    Brickell, Henry M.

    2011-01-01

    Evaluators use their eyes to see what is there, whether it is intended or not. But they use their test instruments to measure what is intended, whether it is there or not. Evaluators have been broadening their repertoire of instruments for years: curriculum-embedded tests, observer checklists, audiotape recorders, videotape recorders, unobtrusive…

  1. Statistical approaches to assessing single and multiple outcome measures in dry eye therapy and diagnosis.

    PubMed

    Tomlinson, Alan; Hair, Mario; McFadyen, Angus

    2013-10-01

    Dry eye is a multifactorial disease which would require a broad spectrum of test measures in the monitoring of its treatment and diagnosis. However, studies have typically reported improvements in individual measures with treatment. Alternative approaches involve multiple, combined outcomes being assessed by different statistical analyses. In order to assess the effect of various statistical approaches to the use of single and combined test measures in dry eye, this review reanalyzed measures from two previous studies (osmolarity, evaporation, tear turnover rate, and lipid film quality). These analyses assessed the measures as single variables within groups, pre- and post-intervention with a lubricant supplement, by creating combinations of these variables and by validating these combinations with the combined sample of data from all groups of dry eye subjects. The effectiveness of single measures and combinations in diagnosis of dry eye was also considered. Copyright © 2013. Published by Elsevier Inc.

  2. Are the fluctuations in dynamic anterior surface aberrations of the human eye chaotic?

    PubMed

    Jayakumar, Varadharajan; Thapa, Damber; Hutchings, Natalie; Lakshminarayanan, Vasudevan

    2013-12-15

    The purpose of the study is to measure chaos in dynamic anterior surface aberrations and examine how it varies between the eyes of an individual. Noninvasive tear breakup time and dynamic corneal surface aberrations were measured for two open-eye intervals of 15 s. The maximal Lyapunov exponent (MLE) was calculated to test the nature of the fluctuations of the dynamic anterior surface aberrations. The average MLE for total higher-order aberration (HOA) was found to be small (+0.0102±0.0072) μm/s. No significant difference in MLE was found between the eyes for HOA (t-test; p=0.131). Data analysis was carried out for individual Zernike coefficients, including vertical prism as it gives a direct measure of the thickness of the tear film over time. The results show that the amount of chaos was small for each Zernike coefficient and not significantly correlated between the eyes.

  3. Effects of Vestibular Rehabilitation on Balance Control in Older People with Chronic Dizziness: A Randomized Clinical Trial.

    PubMed

    Ricci, Natalia Aquaroni; Aratani, Mayra Cristina; Caovilla, Heloísa Helena; Ganança, Fernando Freitas

    2016-04-01

    The aim of this study was to compare the effects of vestibular rehabilitation protocols on balance control in elderly with dizziness. This is a randomized clinical trial with 3-mo follow-up period. The sample was composed of 82 older individuals with chronic dizziness from vestibular disorders. The control group was treated according to the Conventional Cawthorne & Cooksey protocol (n = 40), and the experimental group was submitted to a Multimodal Cawthorne & Cooksey protocol (n = 42). Measures included Dynamic Gait Index, fall history, hand grip strength, Time Up-and-Go Test, sit-to-stand test, multidirectional reach, and static balance tests. With the exception of history of falls, Forward Functional Reach, Unipedal Right and Left Leg Eyes Closed, and Sensorial Romberg Eyes Open, all outcomes improved after treatments. Such results persisted at follow-up period, with the exception of the Tandem Eyes Open and the Timed Up-and-Go manual. The between-group differences for Sensorial Romberg Eyes Closed (4.27 secs) and Unipedal Left Leg Eyes Open (4.08 secs) were significant after treatment, favoring the Multimodal protocol. Both protocols resulted in improvement on elderly's balance control, which was maintained during a short-term period. The multimodal protocol presented better performance on specific static balance tests.

  4. Biomechanics of the Human Posterior Sclera: Age- and Glaucoma-Related Changes Measured Using Inflation Testing

    PubMed Central

    Coudrillier, Baptiste; Tian, Jing; Alexander, Stephen; Myers, Kristin M.; Quigley, Harry A.; Nguyen, Thao D.

    2012-01-01

    Purpose. The objective of this study was to measure the biomechanical response of the human posterior sclera in vitro and to estimate the effects of age and glaucoma. Methods. Scleral specimens from 22 donors with no history of glaucoma and 11 donors with a history of glaucoma were excised 3 mm posterior to the equator and affixed to an inflation chamber. Optic nerve cross-sections were graded to determine the presence of axon loss. The time-dependent inflation response was measured in a series of pressure-controlled load–unload tests to 30 mm Hg and creep tests to 15 and 30 mm Hg. Circumferential and meridional strains were computed from the digital image correlation displacements, and midposterior stresses were determined from pressure and deformed geometry. Results. Among normal specimens, older age was predictive of a stiffer response and a thinner sclera. In the age group 75 to 93, diagnosed glaucoma eyes with axon damage were thicker than normal eyes. Both damaged and undamaged glaucoma eyes had a different strain response in the peripapillary sclera characterized by a stiffer meridional response. Undamaged glaucoma eyes had slower circumferential creep rates in the peripapillary sclera than normal eyes. Glaucoma eyes were not different from normal eyes in stresses and strains in the midposterior sclera. Conclusions. The observed differences in the biomechanical response of normal and glaucoma sclera may represent baseline properties that contribute to axon damage, or may be characteristics that result from glaucomatous disease. PMID:22395883

  5. Subretinal electrical stimulation preserves inner retinal function in RCS rat retina.

    PubMed

    Ciavatta, Vincent T; Mocko, Julie A; Kim, Moon K; Pardue, Machelle T

    2013-01-01

    Previously, studies showed that subretinal electrical stimulation (SES) from a microphotodiode array (MPA) preserves electroretinography (ERG) b-wave amplitude and regional retinal structure in the Royal College of Surgeons (RCS) rat and simultaneously upregulates Fgf2 expression. This preservation appears to be associated with the increased current produced when the MPA is exposed to ERG test flashes, as weekly ERG testing produces greater neuroprotection than biweekly or no testing. Using an infrared source to stimulate the MPA while avoiding potential confounding effects from exposing the RCS retina to high luminance white light, this study examined whether neuroprotective effects from SES increased with subretinal current in a dose-dependent manner. RCS rats (n=49) underwent subretinal implantation surgery at P21 with MPA devices in one randomly selected eye, and the other eye served as the control. Naïve RCS rats (n=25) were also studied. To increase SES current levels, implanted eyes were exposed to 15 min per session of flashing infrared light (IR) of defined intensity, frequency, and duty cycle. Rats were divided into four SES groups that received ERG testing only (MPA only), about 450 µA/cm2 once per week (Low 1X), about 450 µA/cm2 three times per week (Low 3X), and about 1350 µA/cm2 once per week (High 1X). One eye of the control animals was randomly chosen for IR exposure. All animals were followed for 4 weeks with weekly binocular ERGs. A subset of the eyes was used to measure retina Fgf2 expression with real-time reverse-transcription PCR. Eyes receiving SES showed significant preservation of b-wave amplitude, a- and b-wave implicit times, oscillatory potential amplitudes, and post-receptoral parameters (Vmax and log σ) compared to untreated eyes. All SES-treated eyes had similar preservation, regardless of increased SES from IR light exposure. SES-treated eyes tended to have greater retinal Fgf2 expression than untreated eyes, but Fgf2 expression did not increase with IR light. The larger post-receptoral responses (Vmax), greater post-receptoral sensitivity (logσ), and larger oscillatory potentials suggest SES-treated eyes maintained better inner retinal function than the opposite, untreated eyes. This suggests that in addition to preserving photoreceptors in RCS rats, SES may also promote more robust signal transmission through the retinal network compared to the control eyes. These studies suggest that the protective effects of SES on RCS retinal function cannot be improved with additional subretinal current induction from the MPA, or the charge injection provided by ERG Ganzfeld flashes was not adequately mimicked by the flashing IR light used in this study.

  6. Analysis of tear cytokines and clinical correlations in Sjögren syndrome dry eye patients and non-Sjögren syndrome dry eye patients.

    PubMed

    Lee, Sang Yeop; Han, Soo Jung; Nam, Sang Min; Yoon, Sang Chul; Ahn, Ji Min; Kim, Tae-Im; Kim, Eung Kweon; Seo, Kyoung Yul

    2013-08-01

    To compare concentrations of tear cytokines in 3 groups composed of Sjögren syndrome (SS) dry eye, non-Sjögren syndrome (non-SS) dry eye, and normal subjects. Correlations between ocular surface parameters and tear cytokines were also investigated. Prospective cross-sectional study. SS dry eye patients (n = 24; 40 eyes) were diagnosed with primary SS according to the criteria set by the American-European Consensus Group. Non-SS dry eye patients (n = 25; 40 eyes) and normal subjects (n = 21; 35 eyes) were also enrolled. Tear concentrations of interleukin (IL)-17, IL-6, IL-10, IL-4, IL-2, interferon γ (IFN-γ), and tumor necrosis factor α (TNF-α) were measured by a multiplex immunobead assay. Ocular Surface Disease Index (OSDI), tear film breakup time (TBUT), Schirmer I test, and fluorescein staining scores were obtained from dry eye patients. All cytokine levels except for IL-2 were highest in the SS group, followed by non-SS dry eye group and control subjects. Concentrations of IL-17, TNF-α, and IL-6 were significantly different among the 3 groups (IL-17: SS > control P < .001, non-SS > control P = .042, SS > non-SS P < .001; TNF-α: SS > control P = .006, non-SS > control P = .034, SS > non-SS P = .029; IL-6: SS > control P = .002, non-SS > control P = .032, SS > non-SS P = .002). IL-17 was significantly correlated with TBUT (R = -0.22, P = .012) and Schirmer I test (R = -0.36, P = .027) scores in the SS group. IL-6 was significantly correlated only with TBUT (R = -0.38, P = .02) in the non-SS group. Differences in tear cytokine levels and correlation patterns between SS dry eye and non-SS dry eye patients suggest the involvement of different inflammatory processes as causes of dry eye syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Efficacy of corneal eye shields in protecting patients' eyes from laser irradiation.

    PubMed

    Russell, S W; Dinehart, S M; Davis, I; Flock, S T

    1996-07-01

    The continuing development of new types and applications of lasers has appeared to surpass the development of specific eye protection for these lasers. There are a variety of eye shields on the market, but few are specifically designed for laser protection. Our purpose was to test a variety of eye shields by two parameters, light transmission and temperature rise, and to determine from these measurements the most protective shield for patients. We tested four plastic shields, one metal shield, and two sets of tanning goggles for temperature rise and light transmission when irradiated with a beam from a flashlamp-pumped, pulsed-dye laser. The temperature rise at the surface of the shield opposite the laser impacts was no more than 0.2 degree C in any case. White light was transmitted at significant levels through several of the shields, but yellow light transmittance was noted only through the green eye shield. Our measurements indicate that all except the green shield appeared safe from transmission of the 585-nm radiant energy. However, the optimal laser eye shield, in our opinion, would be a composite of several different shields' characteristics.

  8. Right hemisphere advantage for social recognition in the chick.

    PubMed

    Vallortigara, G

    1992-09-01

    Recognition of familiar and unfamiliar conspecifics was studied in pair-reared chicks tested binocularly or with only one eye in use. Chicks were tested on day 3 in pairs composed of either cagemates or strangers. Social discrimination, as measured by the ratio "number of pecks at the strangers/total number of pecks" was impaired in right-eyed chicks with respect to left-eyed and binocular chicks. Male chicks showed higher levels of social pecking than females, and chicks that used both eyes showed higher pecking than monocular chicks. There were no significant differences in the total number of pecks (i.e. pecks at companions plus pecks at strangers) between right- and left-eyed chicks: the impairment in social discrimination of right-eyed chicks seemed to be due partly to a reduction in pecking at strangers and partly to an increase in pecking at companions. It is suggested that neural structures fed by the left eye (mainly located at the right hemisphere) are better at processing and/or storing of visual information which allows recognition of individual conspecifics. This may be part of a wider tendency to respond to small changes in any of a variety of intrinsic stimulus properties.

  9. Antioxidants intake and dry eye syndrome: a crossover, placebo-controlled, randomized trial.

    PubMed

    Drouault-Holowacz, Sophie; Bieuvelet, Séverine; Burckel, André; Rigal, Danièle; Dubray, Claude; Lichon, Jean-Louis; Bringer, Paul; Pilon, Francois; Chiambaretta, Frédéric

    2009-01-01

    To assess whether an orally administered antioxidant dietary supplement could improve the objective clinical signs and alleviate the subjective symptoms of dry eye syndrome. Twenty-four subjects diagnosed with dry eye syndrome were randomized in a crossover, double-blind, controlled, randomized study to receive a placebo or an antioxidants combination (Oxybiane) for 12 weeks. In all subjects, break-up time (BUT) test, Schirmer test, ocular symptoms (sore eyes, burning, itching, sensation of foreign object in the eye, photophobia, sticky eyes, and redness), visual comfort, and general well-being were evaluated weekly. After 12 weeks of supplementation with Oxybiane, both the BUT scores (27.3%+/-8.4% with Oxybiane versus 3.61%+/-4.3% with the placebo, p=0.017) and the Schirmer scores (26.9%+/-14.2% with Oxybiane versus -4.7%+/-3.4% with the placebo, p=0.037) were significantly increased. A significantly improvement was also observed considering subjective clinical symptoms such as burning (p=0.031), itching (p=0.027), sensation of foreign body in eye (p=0.030), and redness (p=0.043). CONCLUSIONS. Supplementation with oral antioxidants can improve both tear stability and quantity but also subjective clinical signs.

  10. Glued intraocular lens implantation for eyes with inadequate capsular support: Analysis of the postoperative visual outcome.

    PubMed

    Mohan, Sujatha; John, Bina; Rajan, Mohan; Malkani, Harsha; Nagalekshmi, S V; Singh, Siddhartha

    2017-06-01

    The aim of this study is to analyze the postoperative visual outcomes of fibrin glue-assisted, suture-less posterior chamber (PC) intraocular lens (IOL) implantation technique in eyes with inadequate capsule support at a tertiary eye care hospital in South India. This is a retrospective, nonrandomized case series. This study analyzes 94 eyes which underwent PC-IOL implantation by fibrin glue-assisted, suture-less technique. All patients who had IOL implants by the fibrin glue-assisted PC-IOL technique from August 2009 to January 2014 were included in the study. Intra- and post-operative complications were analyzed. The postoperative best spectacle-corrected visual acuity (BSCVA) was evaluated and recorded at the end of 6 months. The data were analyzed using SPSS version 16.1 (SPSS Inc., Chicago, Illinois, USA) using two sample paired t-test and independent t-test. A total of 94 eyes of 92 patients that underwent glued IOL implantation over a period of 5 years were analyzed. Out of 94 eyes, 77 eyes (84.6%) maintained or improved on their preoperative BSCVA (P = 0.012). We conclude that glued IOL implantation is a feasible option in rehabilitating patients with aphakia without adequate capsular support.

  11. Dry eye syndrome among computer users

    NASA Astrophysics Data System (ADS)

    Gajta, Aurora; Turkoanje, Daniela; Malaescu, Iosif; Marin, Catalin-Nicolae; Koos, Marie-Jeanne; Jelicic, Biljana; Milutinovic, Vuk

    2015-12-01

    Dry eye syndrome is characterized by eye irritation due to changes of the tear film. Symptoms include itching, foreign body sensations, mucous discharge and transitory vision blurring. Less occurring symptoms include photophobia and eye tiredness. Aim of the work was to determine the quality of the tear film and ocular dryness potential risk in persons who spend more than 8 hours using computers and possible correlations between severity of symptoms (dry eyes symptoms anamnesis) and clinical signs assessed by: Schirmer test I, TBUT (Tears break-up time), TFT (Tear ferning test). The results show that subjects using computer have significantly shorter TBUT (less than 5 s for 56 % of subjects and less than 10 s for 37 % of subjects), TFT type II/III in 50 % of subjects and type III 31% of subjects was found when compared to computer non users (TFT type I and II was present in 85,71% of subjects). Visual display terminal use, more than 8 hours daily, has been identified as a significant risk factor for dry eye. It's been advised to all persons who spend substantial time using computers to use artificial tears drops in order to minimize the symptoms of dry eyes syndrome and prevents serious complications.

  12. Assessing Binocular Interaction in Amblyopia and Its Clinical Feasibility

    PubMed Central

    Kwon, MiYoung; Lu, Zhong-Lin; Miller, Alexandra; Kazlas, Melanie; Hunter, David G.; Bex, Peter J.

    2014-01-01

    Purpose To measure binocular interaction in amblyopes using a rapid and patient-friendly computer-based method, and to test the feasibility of the assessment in the clinic. Methods Binocular interaction was assessed in subjects with strabismic amblyopia (n = 7), anisometropic amblyopia (n = 6), strabismus without amblyopia (n = 15) and normal vision (n = 40). Binocular interaction was measured with a dichoptic phase matching task in which subjects matched the position of a binocular probe to the cyclopean perceived phase of a dichoptic pair of gratings whose contrast ratios were systematically varied. The resulting effective contrast ratio of the weak eye was taken as an indicator of interocular imbalance. Testing was performed in an ophthalmology clinic under 8 mins. We examined the relationships between our binocular interaction measure and standard clinical measures indicating abnormal binocularity such as interocular acuity difference and stereoacuity. The test-retest reliability of the testing method was also evaluated. Results Compared to normally-sighted controls, amblyopes exhibited significantly reduced effective contrast (∼20%) of the weak eye, suggesting a higher contrast requirement for the amblyopic eye compared to the fellow eye. We found that the effective contrast ratio of the weak eye covaried with standard clincal measures of binocular vision. Our results showed that there was a high correlation between the 1st and 2nd measurements (r = 0.94, p<0.001) but without any significant bias between the two. Conclusions Our findings demonstrate that abnormal binocular interaction can be reliably captured by measuring the effective contrast ratio of the weak eye and quantitative assessment of binocular interaction is a quick and simple test that can be performed in the clinic. We believe that reliable and timely assessment of deficits in a binocular interaction may improve detection and treatment of amblyopia. PMID:24959842

  13. Regular examinations for toxic maculopathy in long-term chloroquine or hydroxychloroquine users.

    PubMed

    Nika, Melisa; Blachley, Taylor S; Edwards, Paul; Lee, Paul P; Stein, Joshua D

    2014-10-01

    According to evidence-based, expert recommendations, long-term users of chloroquine or hydroxychloroquine sulfate should undergo regular visits to eye care providers and diagnostic testing to check for maculopathy. To determine whether patients with rheumatoid arthritis (RA) or systemic lupus erythematosus (SLE) taking chloroquine or hydroxychloroquine are regularly visiting eye care providers and being screened for maculopathy. Patients with RA or SLE who were continuously enrolled in a particular managed care network for at least 5 years between January 1, 2001, and December 31, 2011, were studied. Patients' amount of chloroquine or hydroxychloroquine use in the 5 years since the initial RA or SLE diagnosis was calculated, along with their number of eye care visits and diagnostic tests for maculopathy. Those at high risk for maculopathy were identified. Logistic regression was performed to assess potential factors associated with regular eye care visits (annual visits in ≥3 of 5 years) among chloroquine or hydroxychloroquine users, including those at highest risk for maculopathy. Among chloroquine or hydroxychloroquine users and those at high risk for toxic maculopathy, the proportions with regular eye care visits and diagnostic testing, as well as the likelihood of regular eye care visits. Among 18 051 beneficiaries with RA or SLE, 6339 (35.1%) had at least 1 record of chloroquine or hydroxychloroquine use, and 1409 (7.8%) had used chloroquine or hydroxychloroquine for at least 4 years. Among those at high risk for maculopathy, 27.9% lacked regular eye care visits, 6.1% had no visits to eye care providers, and 34.5% had no diagnostic testing for maculopathy during the 5-year period. Among high-risk patients, each additional month of chloroquine or hydroxychloroquine use was associated with a 2.0% increased likelihood of regular eye care (adjusted odds ratio, 1.02; 95% CI, 1.01-1.03). High-risk patients whose SLE or RA was managed by rheumatologists had a 77.4% increased likelihood of regular eye care (adjusted odds ratio, 1.77; 95% CI, 1.27-2.47) relative to other patients. In this insured population, many patients at high risk for maculopathy associated with the use of chloroquine or hydroxychloroquine are not undergoing routine monitoring for this serious adverse effect. Future studies should explore factors contributing to suboptimal adherence to expert guidelines and the potential effect on patients' vision-related outcomes.

  14. LONG-TERM VISUAL OUTCOMES IN EXTREMELY LOW-BIRTH-WEIGHT CHILDREN (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    Spencer, Rand

    2006-01-01

    Purpose The goal is to analyze the long-term visual outcome of extremely low-birth-weight children. Methods This is a retrospective analysis of eyes of extremely low-birth-weight children on whom vision testing was performed. Visual outcomes were studied by analyzing acuity outcomes at ≥36 months of adjusted age, correlating early acuity testing with final visual outcome and evaluating adverse risk factors for vision. Results Data from 278 eyes are included. Mean birth weight was 731g, and mean gestational age at birth was 26 weeks. 248 eyes had grating acuity outcomes measured at 73 ± 36 months, and 183 eyes had recognition acuity testing at 76 ± 39 months. 54% had below normal grating acuities, and 66% had below normal recognition acuities. 27% of grating outcomes and 17% of recognition outcomes were ≤20/200. Abnormal early grating acuity testing was predictive of abnormal grating (P < .0001) and recognition (P = .0001) acuity testing at ≥3 years of age. A slower-than-normal rate of early visual development was predictive of abnormal grating acuity (P < .0001) and abnormal recognition acuity (P < .0001) at ≥3 years of age. Eyes diagnosed with maximal retinopathy of prematurity in zone I had lower acuity outcomes (P = .0002) than did those with maximal retinopathy of prematurity in zone II/III. Eyes of children born at ≤28 weeks gestational age had 4.1 times greater risk for abnormal recognition acuity than did those of children born at >28 weeks gestational age. Eyes of children with poorer general health after premature birth had a 5.3 times greater risk of abnormal recognition acuity. Conclusions Long-term visual development in extremely low-birth-weight infants is problematic and associated with a high risk of subnormal acuity. Early acuity testing is useful in identifying children at greatest risk for long-term visual abnormalities. Gestational age at birth of ≤ 28 weeks was associated with a higher risk of an abnormal long-term outcome. PMID:17471358

  15. Posterior Eye Shape Measurement With Retinal OCT Compared to MRI

    PubMed Central

    Kuo, Anthony N.; Verkicharla, Pavan K.; McNabb, Ryan P.; Cheung, Carol Y.; Hilal, Saima; Farsiu, Sina; Chen, Christopher; Wong, Tien Y.; Ikram, M. Kamran; Cheng, Ching Y.; Young, Terri L.; Saw, Seang M.; Izatt, Joseph A.

    2016-01-01

    Purpose Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. Methods Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical coherence tomography segmentations were corrected for optical and display distortions requiring biometry data. The segmentations were fitted to spheres and ellipsoids to obtain the posterior eye radius of curvature (Rc) and asphericity (Qxz). The differences in Rc and Qxz measured by MRI and OCT were tested using paired t-tests. Categorical assignments of prolateness or oblateness using Qxz were compared. Results Fifty-two subjects (67.8 ± 5.6 years old) with spherical equivalent refraction from +0.50 to −5.38 were included. The mean paired difference between MRI and original OCT posterior eye Rc was 24.03 ± 46.49 mm (P = 0.0005). For corrected OCT images, the difference in Rc decreased to −0.23 ± 2.47 mm (P = 0.51). The difference between MRI and OCT asphericity, Qxz, was −0.052 ± 0.343 (P = 0.28). However, categorical agreement was only moderate (κ = 0.50). Conclusions Distortion-corrected OCT measurements of Rc and Qxz were not statistically significantly different from MRI, although the moderate categorical agreement suggests that individual differences remained. This study provides evidence that with distortion correction, noninvasive office-based OCT could potentially be used instead of MRI for the study of posterior eye shape. PMID:27409473

  16. Personalized Pseudophakic Model for Refractive Assessment

    PubMed Central

    Ribeiro, Filomena J.; Castanheira-Dinis, António; Dias, João M.

    2012-01-01

    Purpose To test a pseudophakic eye model that allows for intraocular lens power (IOL) calculation, both in normal eyes and in extreme conditions, such as post-LASIK. Methods Participants: The model’s efficacy was tested in 54 participants (104 eyes) who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corneal topography. Modelling The Liou-Brennan eye model was used as a starting point, and biometric values were replaced by individual measurements. Detailed corneal surface data were obtained from topography (Orbscan®) and a grid of elevation values was used to define corneal surfaces in an optical ray-tracing software (Zemax®). To determine IOL power, optimization criteria based on values of the modulation transfer function (MTF) weighted according to contrast sensitivity function (CSF), were applied. Results Pre-operative refractive assessment calculated by our eye model correlated very strongly with SRK/T (r = 0.959, p<0.001) with no difference of average values (16.9±2.9 vs 17.1±2.9 D, p>0.05). Comparison of post-operative refractive assessment obtained using our eye model with the average of currently used formulas showed a strong correlation (r = 0.778, p<0.001), with no difference of average values (21.5±1.7 vs 21.8±1.6 D, p>0.05). Conclusions Results suggest that personalized pseudophakic eye models and ray-tracing allow for the use of the same methodology, regardless of previous LASIK, independent of population averages and commonly used regression correction factors, which represents a clinical advantage. PMID:23056450

  17. Improved eye- and skin-color prediction based on 8 SNPs.

    PubMed

    Hart, Katie L; Kimura, Shey L; Mushailov, Vladimir; Budimlija, Zoran M; Prinz, Mechthild; Wurmbach, Elisa

    2013-06-01

    To improve the 7-plex system to predict eye and skin color by increasing precision and detailed phenotypic descriptions. Analysis of an eighth single nucleotide polymorphism (SNP), rs12896399 (SLC24A4), showed a statistically significant association with human eye color (P=0.007) but a rather poor strength of agreement (κ=0.063). This SNP was added to the 7-plex system (rs12913832 at HERC2, rs1545397 at OCA2, rs16891982 at SLC45A2, rs1426654 at SLC24A5, rs885479 at MC1R, rs6119471 at ASIP, and rs12203592 at IRF4). Further, the instruction guidelines on the interpretation of genotypes were changed to create a new 8-plex system. This was based on the analysis of an 803-sample training set of various populations. The newly developed 8-plex system can predict the eye colors brown, green, and blue, and skin colors light, not dark, and not light. It is superior to the 7-plex system with its additional ability to predict blue eye and light skin color. The 8-plex system was tested on an additional 212 samples, the test set. Analysis showed that the number of positive descriptions for eye colors as being brown, green, or blue increased significantly (P=6.98e-15, z-score: -7.786). The error rate for eye-color prediction was low, at approximately 5%, while the skin color prediction showed no error in the test set (1% in training set). We can conclude that the new 8-plex system for the prediction of eye and skin color substantially enhances its former version.

  18. Self-Motion Perception during Locomotor Recalibration: More than Meets the Eye

    ERIC Educational Resources Information Center

    Durgin, Frank H.; Pelah, Adar; Fox, Laura F.; Lewis, Jed; Kane, Rachel; Walley, Katherine A.

    2005-01-01

    Do locomotor after effects depend specifically on visual feedback? In 7 experiments, 116 college students were tested, with closed eyes, at stationary running or at walking to a previewed target after adaptation, with closed eyes, to treadmill locomotion. Subjects showed faster inadvertent drift during stationary running and increased distance…

  19. 49 CFR 571.209 - Standard No. 209; Seat belt assemblies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (1) Eye bolts, shoulder bolts, or other bolt used to secure the pelvic restraint of seat belt... connecting webbing to an eye bolt shall be provided with a retaining latch or keeper which shall not move...) Single attachment hook for connecting webbing to any eye bolt shall be tested in the following manner...

  20. Eye Closure Reduces the Cross-Modal Memory Impairment Caused by Auditory Distraction

    ERIC Educational Resources Information Center

    Perfect, Timothy J.; Andrade, Jackie; Eagan, Irene

    2011-01-01

    Eyewitnesses instructed to close their eyes during retrieval recall more correct and fewer incorrect visual and auditory details. This study tested whether eye closure causes these effects through a reduction in environmental distraction. Sixty participants watched a staged event before verbally answering questions about it in the presence of…

  1. Clinical applications of correlational vestibular autorotation test.

    PubMed

    Hsieh, Li-Chun; Lin, Te-Ming; Chang, Yu-Min; Kuo, Terry B J; Lee, Gho-She

    2015-06-01

    The correlational vestibular autorotation test (VAT) system has the advantages of good test-retest reliability and calibrations of absolute degrees of eye movement are unnecessary when acquiring a cross correlation coefficient (CCC). The approach is able to efficiently detect peripheral vestibulopathies. A VAT has some drawbacks including poor test-retest reliability and slippage of sensor. This study aimed to develop a correlational VAT system and to evaluate the reliability and applicability of this system. Twenty healthy participants and 10 vertiginous patients were enrolled. Vertical and horizontal autorotations from 0 to 3 Hz with either closed or open eyes were performed. A small sensor and a wireless transmission technique were used to acquire the electro-ocular graph and head velocity signals. The two signals were analyzed using CCCs to assess the functioning of the vestibular ocular reflex (VOR). The results showed a significantly greater CCC for open-eye versus closed-eye of head autorotations. The CCCs also increased significantly with head rotational frequencies. Moreover, the CCCs significantly correlated with the VOR gains at autorotation frequencies ≥1.0 Hz. The test-retest reliability was good (intraclass correlation coefficients ≥0.85). The vertiginous participants had significantly lower individual CCCs and overall average CCC than age- and-gender matched controls.

  2. Postural equilibrium following exposure to weightless space flight

    NASA Technical Reports Server (NTRS)

    Homick, J. L.; Reschke, M. F.

    1977-01-01

    Postural equilibrium performance by Skylab crewmen following exposure to weightlessness of 28, 59, and 84 days respectively was evaluated using a modified version of a quantitative ataxia test developed by Graybiel and Fregly (1966). Performance for this test was measured under two sets of conditions. In the first, the crewman was required to maintain postural equilibrium on narrow metal rails (or floor) with his eyes open. In the second condition, he attempted to balance with his eyes closed. A comparison of the preflight and postflight data indicated moderate postflight decrements in postural equilibrium in three of the crewmen during the eyes open test condition. In the eyes-closed condition, a considerable decrease in ability to maintain balance on the rails was observed postflight for all crewmen tested. The magnitude of the change was most pronounced during the first postflight test day. Improvement was slow; however, on the basis of data obtained, recovery of preflight baseline levels of performance was evidently complete at the end of approximately two weeks for all crewmen. The findings are explained in terms of functional alterations in the kinesthetic, touch, vestibular and neuromuscular sensory mechanisms induced by the prolonged absence of a normal 1-G gravitational environment.

  3. Evidence for Trait Related Theory of Mind Impairment in First Episode Psychosis Patients and Its Relationship with Processing Speed: A 3 Year Follow-up Study.

    PubMed

    Ayesa-Arriola, Rosa; Setién-Suero, Esther; Neergaard, Karl D; Ferro, Adele; Fatjó-Vilas, Mar; Ríos-Lago, Marcos; Otero, Soraya; Rodríguez-Sánchez, Jose M; Crespo-Facorro, Benedicto

    2016-01-01

    This study aimed to confirm whether first-episode psychosis patients present a stable trait impairment in theory of mind (ToM) and to examine the potential relationship between ToM and clinical symptomatology and neurocognition. Patients with a first episode of psychosis (N = 160) and healthy controls (N = 159) were assessed with an extensive neuropsychological test battery, which included a mental state decoding task known as "The Reading the Mind in the Eyes" (Eyes test), at baseline and reassessed after 1 and 3 years. The clinical group performed below healthy controls on the Eyes test while not showing test-retest differences between baseline and follow-up administrations. Analyses revealed age, education and premorbid IQ as potential moderators. Poorer performance on the Eyes test was not linked to clinical symptomatology but was associated with greater neurocognitive deficit, particularly related to processing speed. The persistence of ToM deficits in patients suggests that there are trait related metalizing impairments in first episode psychosis. This study shows the influence of processing speed and moderator variables on efficient ToM.

  4. Labial salivary gland transplantation for severe dry eye due to chemical burns and Stevens-Johnson syndrome.

    PubMed

    Marinho, Diane R; Burmann, Tiana G; Kwitko, Sérgio

    2010-01-01

    Salivary gland transplantation has been a promising alternative for the treatment of dry eye syndrome. In this article, we describe the results of an autotransplant procedure of labial salivary glands in the upper conjunctival fornix of patients with severe dry eye. A total of 14 eyes from 14 patients presenting with Stevens-Johnson syndrome and chemical burns were prospectively analyzed after surgery (average follow-up of 14 months). We evaluated their underlying symptoms, visual acuity, biomicroscopy, Schirmer's test, break-up time, and need for lubricants before and after transplantation. All patients expressed improvement in their ocular discomfort. Nine eyes showed a slight best-corrected visual acuity improvement, while the vision of the remainder stayed stable. Corneal staining, present in all patients before surgery, was persistent in only four patients, but in a reduced area. Schirmer's test and break-up time showed significant increase in all patients (p < 0.05). In 71% of the patients, the use of lubricants was reduced. Labial salivary gland transplantation can improve the life quality of patients with compromised ocular surfaces who suffer from severe dry eye syndrome.

  5. Minimum velocity necessary for nonconventional projectiles to penetrate the eye: an experimental study using pig eyes.

    PubMed

    Marshall, John W; Dahlstrom, Dean B; Powley, Kramer D

    2011-06-01

    To satisfy the Criminal Code of Canada's definition of a firearm, a barreled weapon must be capable of causing serious bodily injury or death to a person. Canadian courts have accepted the forensically established criteria of "penetration or rupture of an eye" as serious bodily injury. The minimal velocity of nonconventional ammunition required to penetrate the eye including airsoft projectiles has yet to be established. To establish minimal threshold requirements for eye penetration, empirical tests were conducted using a variety of airsoft projectiles. Using the data obtained from these tests, and previous research using "air gun" projectiles, an "energy density" parameter was calculated for the minimum penetration threshold of an eye. Airsoft guns capable of achieving velocities in excess of 99 m/s (325 ft/s) using conventional 6-mm airsoft ammunition will satisfy the forensically established criteria of "serious bodily injury." The energy density parameter for typical 6-mm plastic airsoft projectiles is 4.3 to 4.8 J/cm². This calculation also encompasses 4.5-mm steel BBs.

  6. Peripheral refraction with eye and head rotation with contact lenses.

    PubMed

    Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M

    2015-04-01

    To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Discordant Dry Eye Disease (An American Ophthalmological Society Thesis)

    PubMed Central

    Shtein, Roni M.; Harper, Daniel E.; Pallazola, Vincent; Harte, Steven E.; Hussain, Munira; Sugar, Alan; Williams, David A.; Clauw, Daniel J.

    2016-01-01

    Purpose To improve understanding of dry eye disease and highlight a subgroup of patients who have a component of central sensitization and neuropathic pain contributing to their condition. Methods Prospective, cross-sectional, IRB-approved study comparing isolated dry eye disease (n=48) to fibromyalgia (positive control; n=23) and healthy (negative control; n=26) individuals with ocular surface examination, corneal confocal microscopy, quantitative sensory testing, and self-reported ocular symptoms and systemic associations. A subset of patients also underwent skin biopsy and/or brain neuroimaging. Dry eye patients were split into concordant (ie, those with dry eyes on examination) and discordant (ie, those with dry eye symptoms but normal examination) subgroups for further analysis. We hypothesized that on the systemic measures included, concordant patients would resemble healthy controls, whereas discordant patients would show evidence of centralized mechanisms similar to fibromyalgia. Results Schirmer test and Ocular Surface Disease Index (OSDI) scores indicated significant decreases in tear production (Schirmer: healthy, 18.5±8.2 mm; dry, 11.2±5.4 mm; fibromyalgia, 14.4±7.5; P<.001) and increases in self-reported dry eye symptoms (OSDI: healthy, 1.9±3.0; dry, 20.3±17.7; fibromyalgia, 20.3±17.1; P<.001) in the dry eye and fibromyalgia patients, compared to controls. The discordant subgroup had decreased corneal nerve density and decreased visual quality-of-life scores, similar to patients with fibromyalgia. Concordant patients were more similar to healthy controls on these measures. Conclusions Individuals with discordant dry eye may have a central pathophysiologic mechanism leading to their eye pain symptoms, which could be an important factor to consider in treatment of chronic idiopathic dry eye. PMID:28050051

  8. Discordant Dry Eye Disease (An American Ophthalmological Society Thesis).

    PubMed

    Shtein, Roni M; Harper, Daniel E; Pallazola, Vincent; Harte, Steven E; Hussain, Munira; Sugar, Alan; Williams, David A; Clauw, Daniel J

    2016-08-01

    To improve understanding of dry eye disease and highlight a subgroup of patients who have a component of central sensitization and neuropathic pain contributing to their condition. Prospective, cross-sectional, IRB-approved study comparing isolated dry eye disease (n=48) to fibromyalgia (positive control; n=23) and healthy (negative control; n=26) individuals with ocular surface examination, corneal confocal microscopy, quantitative sensory testing, and self-reported ocular symptoms and systemic associations. A subset of patients also underwent skin biopsy and/or brain neuroimaging. Dry eye patients were split into concordant (ie, those with dry eyes on examination) and discordant (ie, those with dry eye symptoms but normal examination) subgroups for further analysis. We hypothesized that on the systemic measures included, concordant patients would resemble healthy controls, whereas discordant patients would show evidence of centralized mechanisms similar to fibromyalgia. Schirmer test and Ocular Surface Disease Index (OSDI) scores indicated significant decreases in tear production (Schirmer: healthy, 18.5±8.2 mm; dry, 11.2±5.4 mm; fibromyalgia, 14.4±7.5; P <.001) and increases in self-reported dry eye symptoms (OSDI: healthy, 1.9±3.0; dry, 20.3±17.7; fibromyalgia, 20.3±17.1; P <.001) in the dry eye and fibromyalgia patients, compared to controls. The discordant subgroup had decreased corneal nerve density and decreased visual quality-of-life scores, similar to patients with fibromyalgia. Concordant patients were more similar to healthy controls on these measures. Individuals with discordant dry eye may have a central pathophysiologic mechanism leading to their eye pain symptoms, which could be an important factor to consider in treatment of chronic idiopathic dry eye.

  9. Clinical characterisation and cytological study of dry eye in patients with autoimmune disease.

    PubMed

    Guannan, Huang; Long, Su; Xia, Hua; Dong, Wang; Shaozhen, Zhao

    2018-03-01

    To assess the clinical characteristics and changes in ocular surface cytology of dry eye in patients with systemic autoimmune disease. The case-control study was conducted in the Second Hospital of Tianjin Medical University, Tianjin, China, from February 2016 to January 2017, and comprised systemic autoimmune disease patients and healthy controls. Schirmer's I test, tear breakup time test, and fluorescein staining were performed on all subjects. Both groups were evaluated for dry eye with the current diagnostic criteria. Conjunctival impression cytology and the morphology of epithelial cells were observed in both groups of subjects. Flow cytometry was used to identify the amount of apoptosis. SPSS 15 was used to analyse the data. Each of the two groups had 60(50%) subjects each. The morbidity of dry eye in the control group was 17(28.3%), while it was 31(51.7%) in the patients (p<0.01). Among the patients with dry eye, the severity level of cells obtained by conjunctival impression sampling was significantly higher in patients than in controls (p<0.01). The percentage of conjunctival epithelial cells undergoing apoptosis was higher in patients with dry eye than in patients without dry eye in each group, and among patients with dry eye, the percentage of conjunctival epithelial cells undergoing apoptosis was higher in the patients than in controls (p<0.01 each). The cell injury on the ocular surface was more serious in subjects with dry eye in systemic autoimmune disease than in subjects with dry eye in healthy controls.

  10. Callous-unemotional traits in children and mechanisms of impaired eye contact during expressions of love: a treatment target?

    PubMed

    Dadds, Mark R; Allen, Jennifer L; McGregor, Kimberley; Woolgar, Matthew; Viding, Essi; Scott, Stephen

    2014-07-01

    We previously hypothesised that the early development of psychopathy is associated with a failure to attend to the eyes of attachment figures, and we have presented preliminary data from a parent-child 'love' scenario in support of this. Here, we confirm the association in a larger sample and test mechanisms of impaired eye contact during expressions of love in control and behaviourally disturbed children. Oppositional defiant disorder children, assessed for callous-unemotional (CU) traits, and controls, were observed in a brief interaction task where the mother was asked to show love to her child. Eye contact and affection were measured for each dyad. As predicted, there were no group differences in affection and eye contact expressed by mothers; levels of CU traits predicted low levels of eye contact towards their mothers across all groups of children. As expected, low eye contact was correlated with psychopathic fearlessness in their fathers, and maternal reports of negative feelings towards the child. Independent observations showed that child's behaviour largely drives the low eye contact associated with CU traits, and low eye contact was not associated with independent observations of the quality of attachment-related behaviours in mothers. Impaired eye contact is a unique characteristic of children with CU traits; these impairments are largely independent of maternal behaviour, but associated with psychopathic traits in the fathers. These impairments should be tested for functional significance and amenability to change in longitudinal and treatment studies. © 2013 The Authors. Journal of Child Psychology and Psychiatry © 2013 Association for Child and Adolescent Mental Health.

  11. Difference in Visual Processing Assessed by Eye Vergence Movements

    PubMed Central

    Solé Puig, Maria; Puigcerver, Laura; Aznar-Casanova, J. Antonio; Supèr, Hans

    2013-01-01

    Orienting visual attention is closely linked to the oculomotor system. For example, a shift of attention is usually followed by a saccadic eye movement and can be revealed by micro saccades. Recently we reported a novel role of another type of eye movement, namely eye vergence, in orienting visual attention. Shifts in visuospatial attention are characterized by the response modulation to a selected target. However, unlike (micro-) saccades, eye vergence movements do not carry spatial information (except for depth) and are thus not specific to a particular visual location. To further understand the role of eye vergence in visual attention, we tested subjects with different perceptual styles. Perceptual style refers to the characteristic way individuals perceive environmental stimuli, and is characterized by a spatial difference (local vs. global) in perceptual processing. We tested field independent (local; FI) and field dependent (global; FD) observers in a cue/no-cue task and a matching task. We found that FI observers responded faster and had stronger modulation in eye vergence in both tasks than FD subjects. The results may suggest that eye vergence modulation may relate to the trade-off between the size of spatial region covered by attention and the processing efficiency of sensory information. Alternatively, vergence modulation may have a role in the switch in cortical state to prepare the visual system for new incoming sensory information. In conclusion, vergence eye movements may be added to the growing list of functions of fixational eye movements in visual perception. However, further studies are needed to elucidate its role. PMID:24069140

  12. Reconceptualizing Reactivity of Think-Alouds and Eye Tracking: Absence of Evidence Is Not Evidence of Absence

    ERIC Educational Resources Information Center

    Godfroid, Aline; Spino, Le Anne

    2015-01-01

    This study extends previous reactivity research on the cognitive effects of think-alouds to include eye-tracking methodology. Unlike previous studies, we supplemented traditional superiority tests with equivalence tests, because only the latter are conceptually appropriate for demonstrating nonreactivity. Advanced learners of English read short…

  13. 16 CFR 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... noted below. (2) The eyes are examined and the grade of ocular reaction is recorded at 24, 48, and 72 hours. Reading of reactions is facilitated by use of a binocular loupe, hand slit-lamp, or other expert... positive reaction if the test substance produces at any of the readings ulceration of the cornea (other...

  14. Validity and reliability of the Nintendo Wii Balance Board to assess standing balance and sensory integration in highly functional older adults.

    PubMed

    Scaglioni-Solano, Pietro; Aragón-Vargas, Luis F

    2014-06-01

    Standing balance is an important motor task. Postural instability associated with age typically arises from deterioration of peripheral sensory systems. The modified Clinical Test of Sensory Integration for Balance and the Tandem test have been used to screen for balance. Timed tests present some limitations, whereas quantification of the motions of the center of pressure (CoP) with portable and inexpensive equipment may help to improve the sensitivity of these tests and give the possibility of widespread use. This study determines the validity and reliability of the Wii Balance Board (Wii BB) to quantify CoP motions during the mentioned tests. Thirty-seven older adults completed three repetitions of five balance conditions: eyes open, eyes closed, eyes open on a compliant surface, eyes closed on a compliant surface, and tandem stance, all performed on a force plate and a Wii BB simultaneously. Twenty participants repeated the trials for reliability purposes. CoP displacement was the main outcome measure. Regression analysis indicated that the Wii BB has excellent concurrent validity, and Bland-Altman plots showed good agreement between devices with small mean differences and no relationship between the difference and the mean. Intraclass correlation coefficients (ICCs) indicated modest-to-excellent test-retest reliability (ICC=0.64-0.85). Standard error of measurement and minimal detectable change were similar for both devices, except the 'eyes closed' condition, with greater standard error of measurement for the Wii BB. In conclusion, the Wii BB is shown to be a valid and reliable method to quantify CoP displacement in older adults.

  15. Sit-to-stand ground reaction force characteristics in blind and sighted female children.

    PubMed

    Faraji Aylar, Mozhgan; Jafarnezhadgero, Amir Ali; Salari Esker, Fatemeh

    2018-03-05

    The association between visual sensory and sit-to-stand ground reaction force characteristics is not clear. Impulse is the amount of force applied over a period of time. Also, free moment represents the vertical moment applied in the center of pressure (COP). How the ground reaction force components, vertical loading rate, impulses and free moment respond to long and short term restricted visual information? Fifteen female children with congenital blindness and 45 healthy girls with no visual impairments participated in this study. The girls with congenital blindness were placed in one group and the 45 girls with no visual impairments were randomly divided into three groups of 15; eyes open, permanently eyes closed, and temporary eyes closed. The participants in the permanently eyes closed group closed their eyes for 20 min before the test, whereas temporary eyes closed group did tests with their eyes closed throughout, and those in the eyes open group kept their eyes open. Congenital blindness was associated with increased vertical loading rate, range of motion of knee and hip in the medio-lateral plane. Also, medio-lateral and vertical ground reaction force impulses. Similar peak negative and positive free moments were observed in three groups. In conclusion, the results reveal that sit-to-stand ground reaction force components in blind children may have clinical importance for improvement of balance control of these individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Dry eye and meibomian gland dysfunction in pseudophakic bullous keratopathy.

    PubMed

    Palamar, Melis; Kiyat, Pelin; Yagci, Ayse

    2018-02-01

    To evaluate dry eye tests and meibography of patients with pseudophakic bullous keratopathy (PBK). Thirty-seven patients with PBK were included. The eyes with PBK were compared with the normal pseudophakic fellow eyes. All patients had undergone a detailed ophthalmic examination including corneal and conjunctival fluorescein staining and Oxford scoring, tear film breakup time, Schirmer 1 test, Ocular Surface Disease Index (OSDI) score assessment, lid margin abnormalities, upper and lower eyelid Meibomian gland evaluation using infrared captures of a biomicroscope. Partial or complete loss of the Meibomian glands (Meibomian dropout) was scored for each eyelid from grade 0 (no loss) through grade 3 (lost area was > 2/3 of the total meibomian gland area). The mean age of the patients was 73.2 ± 8.9 (range, 50-93). Mean tear film breakup time value was statistically lower in PBK eyes (P ≤ 0.001). OSDI, Oxford, lid margin abnormalities, inferior meibography, total meibography score were significantly higher in PBK eyes (P ≤ 0.001). The comparison of Schirmer 1 and superior meibography scores of the groups was insignificant (P = 0.143, P = 0.793, respectively). The Meibomian gland morphology of the PBK eyes demonstrates significant differences when compared with normal fellow eyes and might be related to evaporative dry eye. For this reason, patients with PBK should be monitored for Meibomian gland dysfunction and when needed start prompt treatment in order to prevent further disturbance of the ocular surface.

  17. Current landscape of direct-to-consumer genetic testing and its role in ophthalmology: a review.

    PubMed

    Sanfilippo, Paul G; Kearns, Lisa S; Wright, Philip; Mackey, David A; Hewitt, Alex W

    2015-08-01

    The sequencing of the human genome has seen the emergence of the direct-to-consumer (DTC) genetic-testing market, which allows individuals to obtain information about their genetic profile and its many health and lifestyle implications. Genetics play an important role in the development of many eye diseases, however, little information is available describing the influence of the DTC industry in ophthalmology. In this review, we examined DTC companies providing genetic test products for eye disease. Of all eye conditions, the majority of DTC companies provided susceptibility testing or risk assessment for age-related macular degeneration (AMD). For the 15 companies noted to offer products, we found considerable variation in the cost, scope and clarity of informational content of DTC genetic testing for ophthalmic conditions. The clinical utility of these tests remains in question, and the American Academy of Ophthalmology recommendations against routine testing for many conditions probably still apply. © 2015 Royal Australian and New Zealand College of Ophthalmologists.

  18. Ocular Surface Disease in Glaucoma: Effect of Polypharmacy and Preservatives.

    PubMed

    Ramli, Norlina; Supramaniam, Gowri; Samsudin, Amir; Juana, Azida; Zahari, Mimiwati; Choo, May May

    2015-09-01

    To evaluate the prevalence of ocular surface disease (OSD) in glaucoma and nonglaucoma subjects using different clinical tests and to determine the effect of number of antiglaucoma medications and preservatives on OSD. This is a cross-sectional, case-comparison study at the Eye Clinic of the University of Malaya Medical Centre, Malaysia, between June 2012 and January 2013. Glaucoma subjects (n = 105) using topical antiglaucoma medications were compared with control subjects (n = 102) who were not on any topical medications. The presence of OSD was assessed using the tear film breakup time (TBUT) test, corneal staining, Schirmer test, and Ocular Surface Disease Index (OSDI) questionnaire grading. The prevalence of OSD varied from 37 to 91% in the glaucoma group, depending on the type of clinical test. More subjects in the glaucoma group had corneal staining (63% vs. 36%, p = 0.004), abnormal Schirmer tests (39% vs. 25%, p = 0.049), and moderate OSDI symptoms (17% vs. 7%, p = 0.028). The percentage with abnormal TBUT increased with higher numbers of topical medications and was high with both benzalkonium chloride-containing and preservative-free eye drops (90% and 94%, respectively, both p < 0.001). Benzalkonium chloride was associated with a nearly three times higher odds ratio of showing abnormal OSDI. Ocular surface disease is common in those using topical antiglaucoma medications. Abnormal TBUT is associated with increasing number of eye drops and benzalkonium chloride-containing eye drops, although this also occurs with the use of preservative-free eye drops.

  19. Modified visual field trend analysis.

    PubMed

    De Moraes, Carlos Gustavo V; Ritch, Robert; Tello, Celso; Liebmann, Jeffrey M

    2011-01-01

    Visual field trend analysis can be influenced by outlying values that may disproportionately affect estimation of the rate of change. We tested a modified approach to visual field trend analysis to minimize this problem. Automated pointwise linear regression (PLR) was used in glaucoma patients with ≥13 SITA-Standard 24-2 VF tests in either eye. In the control group (Group A), conventional PLR using the entire set of VF tests was carried out. In the other 3 groups (study groups), a truncated analysis was done using only the first and last 3 (Group B), first and last 4 (Group C), or first and last 5 (Group D) VF tests. We compared the global slopes (dB/y), number of eyes experiencing significant progression, and significant improvement between groups. Ninety eyes of 90 patients were evaluated. The mean number±SD of VF tests was 15.7±2.6, spanning 7.8±1.7 years. The study groups showed similar global rates of VF change as the control group (Group A=-0.48±0.5, Group B=-0.48±0.6, Group C=-0.48±0.6, Group D=-0.48±0.5 dB/y, P>0.05), and a similar number of eyes reaching a progression endpoint (Group A=53, Group B=52, Group C=49, Group D=53, P>0.05). However, Group B showed fewer eyes presenting VF improvement (false-positives). The modified VF trend-analysis showed greater specificity than conventional PLR in a population with glaucoma.

  20. Psychophysical assessment of low visual function in patients with retinal degenerative diseases (RDDs) with the Diagnosys full-field stimulus threshold (D-FST).

    PubMed

    Klein, M; Birch, D G

    2009-12-01

    To determine whether the Diagnosys full-field stimulus threshold (D-FST) is a valid, sensitive and repeatable psychophysical method of measuring and following visual function in low-vision subjects. Fifty-three affected eyes of 42 subjects with severe retinal degenerative diseases (RDDs) were tested with achromatic stimuli on the D-FST. Included were subjects who were either unable to perform a static perimetric field or had non-detectable or sub-microvolt electroretinograms (ERGs). A subset of 21 eyes of 17 subjects was tested on both the D-FST and the FST2, a previous established full-field threshold test. Seven eyes of 7 normal control subjects were tested on both the D-FST and the FST2. Results for the two methods were compared with the Bland-Altman test. On the D-FST, a threshold could successfully be determined for 13 of 14 eyes with light perception (LP) only (median 0.9 +/- 1.4 log cd/m2), and all eyes determined to be counting fingers (CF; median 0.3 +/- 1.8 log cd/m2). The median full-field threshold for the normal controls was -4.3 +/- 0.6 log cd/m2 on the D-FST and -4.8 +/- 0.9 log cd/m2 on the FST2. The D-FST offers a commercially available method with a robust psychophysical algorithm and is a useful tool for following visual function in low vision subjects.

  1. Glaucoma-Diagnostic Ability of Ganglion Cell-Inner Plexiform Layer Thickness Difference Across Temporal Raphe in Highly Myopic Eyes.

    PubMed

    Kim, Young Kook; Yoo, Byeong Wook; Jeoung, Jin Wook; Kim, Hee Chan; Kim, Hae Jin; Park, Ki Ho

    2016-11-01

    To evaluate the glaucoma-diagnostic ability of the ganglion cell-inner plexiform layer (GCIPL) thickness difference across the temporal raphe in highly myopic eyes. We consecutively enrolled a total of 195 highly myopic eyes (axial length [AL] >26.5 mm) of 195 subjects: 93 glaucoma patients along with and 102 nonglaucomatous subjects. Cirrus high-definition optical coherence tomography (OCT) was employed to scan all of the subjects' macular and optic discs. Using a MATLAB-based customized program (the GCIPL hemifield test), a positive test result was automatically declared if the following two conditions were met: (1) the horizontal line is detected for longer than one-half of the distance from the temporal inner elliptical annulus to the outer elliptical annulus, and (2) the average GCIPL thickness difference within 10 pixels of the reference line, both above and below, is 5 μm or more. The glaucoma-diagnostic ability was computed using the area under the receiver operating characteristic curve (AUC). Among the glaucomatous eyes, GCIPL hemifield test positivity was shown in 92.5% (86 of 93), significantly higher than that for the nonglaucomatous eyes (4.90%, 5 of 102; P <0.001). The value of AUC for the GCIPL hemifield test was excellent (0.938; sensitivity 92.50%, specificity 95.10%) and was the best compared with those for any of OCT parameters. In highly myopic eyes, determination of the presence or absence of GCIPL thickness difference across the temporal raphe via OCT macula scan can be a useful means of distinguishing the glaucomatous damage.

  2. A new nonhuman primate model of severe dry eye.

    PubMed

    Qin, Yi; Tan, Xiaobo; Zhang, Yingnan; Jie, Ying; Labbe, Antoine; Pan, Zhiqiang

    2014-05-01

    The aim of this study was to establish a new rhesus monkey model of severe dry eye. A total of 8 rhesus monkeys were used for the study. Four monkeys had their main lacrimal gland and nictitating membrane surgically removed (group 1). Another 4 monkeys had a similar surgery with further application of 50% trichloroacetic acid on the bulbar conjunctiva (group 2). The ocular surface was evaluated before and after the surgery (1, 4, 8, 12, and 24 weeks) using Schirmer-1 test, corneal fluorescein staining, and the lissamine green test. Conjunctival impression cytology was also performed before and 24 weeks after the surgery. Finally, the cornea and the conjunctiva were evaluated using light microscopy. A significant decrease in tear secretion was observed in all operated eyes. Schirmer test data measured were ≤4 mm in all the operated eyes. Slit-lamp examination also revealed abnormal staining in all the operated eyes that remained stable until the end of the experiment. In group 2, corneal fluorescein staining and lissamine green test values were always ≥5 (max 12) and ≥4 (max 9), respectively. Impression cytology specimens of both the treated groups showed conjunctival squamous metaplasia and a decreased number of goblet cells. Under light microscopy, the corneal epithelium appeared irregular with edematous basal epithelial cells. The conjunctiva showed a decreased goblet cell density with infiltration of inflammatory cells. Complete removal of the principal lacrimal gland and nictitating membrane associated with the application of 50% trichloroacetic acid on the conjunctiva could induce severe dry eye in rhesus monkeys.

  3. Vestibuloocular reflex of rhesus monkeys after spaceflight

    NASA Technical Reports Server (NTRS)

    Cohen, Bernard; Kozlovskaia, Inessa; Raphan, Theodore; Solomon, David; Helwig, Denice; Cohen, Nathaniel; Sirota, Mikhail; Iakushin, Sergei

    1992-01-01

    The vestibuloocular reflex (VOR) of two rhesus monkeys was recorded before and after 14 days of spaceflight. The gain (eye velocity/head velocity) of the horizontal VOR, tested 15 and 18 h after landing, was approximately equal to preflight values. The dominant time constant of the animal tested 15 h after landing was equivalent to that before flight. During nystagmus induced by off-vertical axis rotation (OVAR), the latency, rising time constant, steady-state eye velocity, and phase of modulation in eye velocity and eye position with respect to head position were similar in both monkeys before and after flight. There were changes in the amplitude of modulation of horizontal eye velocity during steady-state OVAR and in the ability to discharge stored activity rapidly by tilting during postrotatory nystagmus (tilt dumping) after flight: OVAR modulations were larger, and tilt dumping was lost in the one animal tested on the day of landing and for several days thereafter. If the gain and time constant of the horizontal VOR exchange in microgravity, they must revert to normal soon after landing. The changes that were observed suggest that adaptation to microgravity had caused alterations in way that the central nervous system processes otolith input.

  4. Hypothesis test for synchronization: twin surrogates revisited.

    PubMed

    Romano, M Carmen; Thiel, Marco; Kurths, Jürgen; Mergenthaler, Konstantin; Engbert, Ralf

    2009-03-01

    The method of twin surrogates has been introduced to test for phase synchronization of complex systems in the case of passive experiments. In this paper we derive new analytical expressions for the number of twins depending on the size of the neighborhood, as well as on the length of the trajectory. This allows us to determine the optimal parameters for the generation of twin surrogates. Furthermore, we determine the quality of the twin surrogates with respect to several linear and nonlinear statistics depending on the parameters of the method. In the second part of the paper we perform a hypothesis test for phase synchronization in the case of experimental data from fixational eye movements. These miniature eye movements have been shown to play a central role in neural information processing underlying the perception of static visual scenes. The high number of data sets (21 subjects and 30 trials per person) allows us to compare the generated twin surrogates with the "natural" surrogates that correspond to the different trials. We show that the generated twin surrogates reproduce very well all linear and nonlinear characteristics of the underlying experimental system. The synchronization analysis of fixational eye movements by means of twin surrogates reveals that the synchronization between the left and right eye is significant, indicating that either the centers in the brain stem generating fixational eye movements are closely linked, or, alternatively that there is only one center controlling both eyes.

  5. The feasibility of automated eye tracking with the Early Childhood Vigilance Test of attention in younger HIV-exposed Ugandan children.

    PubMed

    Boivin, Michael J; Weiss, Jonathan; Chhaya, Ronak; Seffren, Victoria; Awadu, Jorem; Sikorskii, Alla; Giordani, Bruno

    2017-07-01

    Tobii eye tracking was compared with webcam-based observer scoring on an animation viewing measure of attention (Early Childhood Vigilance Test; ECVT) to evaluate the feasibility of automating measurement and scoring. Outcomes from both scoring approaches were compared with the Mullen Scales of Early Learning (MSEL), Color-Object Association Test (COAT), and Behavior Rating Inventory of Executive Function for preschool children (BRIEF-P). A total of 44 children 44 to 65 months of age were evaluated with the ECVT, COAT, MSEL, and BRIEF-P. Tobii ×2-30 portable infrared cameras were programmed to monitor pupil direction during the ECVT 6-min animation and compared with observer-based PROCODER webcam scoring. Children watched 78% of the cartoon (Tobii) compared with 67% (webcam scoring), although the 2 measures were highly correlated (r = .90, p = .001). It is possible for 2 such measures to be highly correlated even if one is consistently higher than the other (Bergemann et al., 2012). Both ECVT Tobii and webcam ECVT measures significantly correlated with COAT immediate recall (r = .37, p = .02 vs. r = .38, p = .01, respectively) and total recall (r = .33, p = .06 vs. r = .42, p = .005) measures. However, neither the Tobii eye tracking nor PROCODER webcam ECVT measures of attention correlated with MSEL composite cognitive performance or BRIEF-P global executive composite. ECVT scoring using Tobii eye tracking is feasible with at-risk very young African children and consistent with webcam-based scoring approaches in their correspondence to one another and other neurocognitive performance-based measures. By automating measurement and scoring, eye tracking technologies can improve the efficiency and help better standardize ECVT testing of attention in younger children. This holds promise for other neurodevelopmental tests where eye movements, tracking, and gaze length can provide important behavioral markers of neuropsychological and neurodevelopmental processes associated with such tests. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  6. Effect of Oral Lactoferrin on Cataract Surgery Induced Dry Eye: A Randomised Controlled Trial.

    PubMed

    Devendra, Jaya; Singh, Sneha

    2015-10-01

    Cataract surgery is one of the most frequently performed intra-ocular surgeries, of these manual Small Incision Cataract Surgery (SICS) is a time tested technique of cataract removal. Any corneal incisional surgery, including cataract surgery, can induce dry eye postoperatively. Various factors have been implicated, of which oneis the inflammation induced by the surgery. Lactoferrin, a glycoprotein present in tears is said to have anti-inflammatory effects, and promotes cell growth. It has been used orally in patients of immune mediated dry eye to alleviate symptoms. This study was aimed to evaluate the dry eyes induced by manual Small Incision Cataract Surgery, and the effect if any, of oral lactoferrin on the dry eyes. A single centre, prospective randomised controlled trial with a concurrent parallel design. The study was carried out on patients presenting in the OPD of Rohilkhand Medical College hospital for cataract surgery. Sixty four patients of cataract surgery were included in the study. Patients with pre-existing dry eyes, ocular disease or systemic disease predisposing to dry eyes were excluded from the study. The selected patients were assigned into two groups by simple randomisation-Control Group A-32 patients that did not receive oral lactoferrin postoperatively. Group B-32 patients that received oral lactoferrin 350 gm postoperatively from day 1 after SICS. All patients were operated for cataract and their pre and postoperative (on days 7, 14, 30 and 60) dry eye status was assessed using the mean tear film break-up time (tBUT) and Schirmer test 1 (ST 1) as the evaluating parameters. Subjective evaluation of dry eye was done using Ocular Surface Disease Index (OSDI) scoring. Data was analysed for 58 patients, as 6 did not complete the follow up. Unpaired t-test was used to calculate the p-values. There was a statistically significant difference between the tBUT values of the Control and Lactoferrin group from day 14 onwards. The tBUT of control group on day 60 was 7.86 (±0.86) seconds as compared to 13.9(± 0.99) seconds in the lactoferrin group. The Schirmer test 1 values also showed a statistically significant difference between the two groups- 15.86 (± 5.83) seconds in the control group versus 30.9 (±1.66) in the lactoferrin group on day 60. OSDI score showed 42.8% patients complaining of at least mild dry eye symptoms in the control group, as compared to 26.6% patients in the lactoferrin group on day 60. Small Incision Cataract Surgery induces dry eye postoperatively. Oral lactoferrin given postoperatively improves tear film status and dry eye after cataract surgery.

  7. Investigating the effect of Eye Movement Desensitization and Reprocessing (EMDR) on postoperative pain intensity in adolescents undergoing surgery: a randomized controlled trial.

    PubMed

    Maroufi, Mohsen; Zamani, Shahla; Izadikhah, Zahra; Marofi, Maryam; O'Connor, Peter

    2016-09-01

    To investigate the efficacy of Eye Movement Desensitization and Reprocessing for postoperative pain management in adolescents. Eye Movement Desensitization and Reprocessing is an inexpensive, non-pharmacological intervention that has successfully been used to treat chronic pain. It holds promise in the treatment of acute, postsurgical pain based on its purported effects on the brain and nervous system. A randomized controlled trial was used. Fifty-six adolescent surgical patients aged between 12-18 years were allocated to gender-balanced Eye Movement Desensitization and Reprocessing (treatment) or non-Eye Movement Desensitization and Reprocessing (control) groups. Pain was measured using the Wong-Baker FACES(®) Pain Rating Scale (WBFS) before and after the intervention (or non-intervention for the control group). A Wilcoxon signed-rank test demonstrated that the Eye Movement Desensitization and Reprocessing group experienced a significant reduction in pain intensity after treatment intervention, whereas the control group did not. Additionally, a Mann-Whitney U-test showed that, while there was no significant difference between the two groups at time 1, there was a significant difference in pain intensity between the two groups at time 2, with the Eye Movement Desensitization and Reprocessing group experiencing lower levels of pain. These results suggest that Eye Movement Desensitization and Reprocessing may be an effective treatment modality for postoperative pain. © 2016 John Wiley & Sons Ltd.

  8. Stereoacuity in children with anisometropic amblyopia.

    PubMed

    Wallace, David K; Lazar, Elizabeth L; Melia, Michele; Birch, Eileen E; Holmes, Jonathan M; Hopkins, Kristine B; Kraker, Raymond T; Kulp, Marjean T; Pang, Yi; Repka, Michael X; Tamkins, Susanna M; Weise, Katherine K

    2011-10-01

    To determine factors associated with pretreatment and posttreatment stereoacuity in subjects with moderate anisometropic amblyopia. Data for subjects enrolled in seven studies conducted by the Pediatric Eye Disease Investigator Group were pooled. The sample included 633 subjects aged 3 to <18 years with anisometropic amblyopia, no heterotropia observed by cover test, and baseline amblyopic eye acuity of 20/100 or better. A subset included 248 subjects who were treated with patching or Bangerter filters and had stereoacuity testing at both the baseline and outcome examinations. Multivariate regression models identified factors associated with baseline stereoacuity and with outcome stereoacuity as measured by the Randot Preschool Stereoacuity test. Better baseline stereoacuity was associated with better baseline amblyopic eye acuity (P < 0.001), less anisometropia (P = 0.03), and anisometropia due to astigmatism alone (P < 0.001). Better outcome stereoacuity was associated with better baseline stereoacuity (P < 0.001) and better amblyopic eye acuity at outcome (P < 0.001). Among 48 subjects whose amblyopic eye visual acuity at outcome was 20/25 or better and within one line of the fellow eye, stereoacuity was worse than that of children with normal vision of the same age. In children with anisometropic amblyopia of 20/40 to 20/100 inclusive, better posttreatment stereoacuity is associated with better baseline stereoacuity and better posttreatment amblyopic eye acuity. Even if their visual acuity deficit resolves, many children with anisometropic amblyopia have stereoacuity worse than that of nonamblyopic children of the same age. Copyright © 2011 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  9. Aggressive posterior retinopathy of prematurity in Asian Indian babies: spectrum of disease and outcome after laser treatment.

    PubMed

    Sanghi, Gaurav; Dogra, Mangat R; Das, Pranab; Vinekar, Anand; Gupta, Amod; Dutta, Saurabh

    2009-10-01

    To analyze the spectrum of aggressive posterior retinopathy of prematurity and outcome after laser treatment. This is a retrospective review of 81 eyes of 44 consecutive infants diagnosed to have aggressive posterior retinopathy of prematurity and treated between September 2005 and March 2007 from a large tertiary care center in North India. Qualitative variables were tested for statistical significance using the chi-square test and independent samples with the student's t-test. Mean birth weight and gestational age were 1,259.66 +/- 310.51 g (range, 660-2,000 g) and 29.75 +/- 2.35 weeks (range, 26-36 weeks), respectively. Twenty-one infants (47.72%) had a birth weight > 1,250 g. Thirty-three (40.74%) eyes had Zone 1, and 48 (59.26%) had posterior Zone 2 disease. All eyes underwent confluent laser photocoagulation at a mean postconceptional age of 34.58 +/- 2.19 weeks (range, 31-40.5 weeks). Mean follow-up was 12.8 months (range, 6-24 months). At the last follow-up visit, 55 (71.4%) of 77 eyes had a favorable outcome. Eighteen eyes (23.4%) had a localized (1-3 clock hours) partial peripheral tractional detachment (Stage 4a), which remained stable at last follow-up. Two eyes (2.6%) developed falciform fold involving the macular area, and 2 (2.6%) developed Stage 5 retinopathy of prematurity. Aggressive posterior retinopathy of prematurity is encountered not only in low birth weight infants, but also in heavier and more mature Asian Indian infants. Early, aggressive confluent laser photocoagulation is necessary to maximize outcomes in these eyes.

  10. Human Factor and Usability Testing of a Binocular Optical Coherence Tomography System

    PubMed Central

    Chopra, Reena; Mulholland, Pádraig J.; Dubis, Adam M.; Anderson, Roger S.; Keane, Pearse A.

    2017-01-01

    Purpose To perform usability testing of a binocular optical coherence tomography (OCT) prototype to predict its function in a clinical setting, and to identify any potential user errors, especially in an elderly and visually impaired population. Methods Forty-five participants with chronic eye disease (mean age 62.7 years) and 15 healthy controls (mean age 53 years) underwent automated eye examination using the prototype. Examination included ‘whole-eye' OCT, ocular motility, visual acuity measurement, perimetry, and pupillometry. Interviews were conducted to assess the subjective appeal and ease of use for this cohort of first-time users. Results All participants completed the full suite of tests. Eighty-one percent of the chronic eye disease group, and 79% of healthy controls, found the prototype easier to use than common technologies, such as smartphones. Overall, 86% described the device to be appealing for use in a clinical setting. There was no statistically significant difference in the total time taken to complete the examination between participants with chronic eye disease (median 702 seconds) and healthy volunteers (median 637 seconds) (P = 0.81). Conclusion On their first use, elderly and visually impaired users completed the automated examination without assistance. Binocular OCT has the potential to perform a comprehensive eye examination in an automated manner, and thus improve the efficiency and quality of eye care. Translational Relevance A usable binocular OCT system has been developed that can be administered in an automated manner. We have identified areas that would benefit from further development to guide the translation of this technology into clinical practice. PMID:28824827

  11. Environmental testing and laser transmission results for ruggedized high power IR fiber cables

    NASA Astrophysics Data System (ADS)

    Busse, Lynda; Kung, Frederic; Florea, Catalin; Shaw, Brandon; Aggarwal, Ishwar; Sanghera, Jas

    2013-03-01

    We present successful results of high mid-IR laser power transmission as well as MIL-SPEC environmental testing (thermal cycling and vibration testing) of ruggedized, IR-transmitting chalcogenide glass fiber cables. The cables tested included chalcogenide fiber cables with endfaces imprinted with anti-reflective "moth eye" surfaces, whereby the reflection loss is reduced from about 17% per end to less than 3%. The cables with these moth eye surfaces also show excellent laser damage resistance.

  12. The coordinate system of the eye in cataract surgery: Performance comparison of the circle Hough transform and Daugman's algorithm

    NASA Astrophysics Data System (ADS)

    Vlachynska, Alzbeta; Oplatkova, Zuzana Kominkova; Sramka, Martin

    2017-07-01

    The aim of the work is to determine the coordinate system of an eye and insert a polar-axis system into images captured by a slip lamp. The image of the eye with the polar axis helps a surgeon accurately implant toric intraocular lens in the required position/rotation during the cataract surgery. In this paper, two common algorithms for pupil detection are compared: the circle Hough transform and Daugman's algorithm. The procedures were tested and analysed on the anonymous data set of 128 eyes captured at Gemini eye clinic in 2015.

  13. Retinal detachment

    MedlinePlus

    ... eye, including the retina ( ophthalmoscopy ) Checking eyeglass prescription ( refraction test ) Checking color vision Checking the smallest letters ... of the first symptoms of new flashes of light and floaters. Prevention Use protective eye wear to ...

  14. Christoph Scheiner and the optics of the eye. (German Title: Christoph Scheiner und die Optik des Auges)

    NASA Astrophysics Data System (ADS)

    Daxecker, Franz

    Some of Scheiner's discoveries and experiments are taken from the books «Oculus», (Innsbruck 1619) and «Rosa Ursina sive Sol» (Rome 1626-1630): determination of the radius of curvature of the cornea, discovery of the nasal exit of the visual nerve, increase in the curvature of the lens in case of accommodation, anatomy of the eye, light reaction of the pupil, contraction of the pupil during accommodation, Scheiner's test (double images caused by ametropia), stenopeic effect, crossing rays in the eye, aperture, description of the cataract treatment, refractive indices of various parts of the eye, eye model, visual pivot angle of the eye, proof of crossing rays on the retina, comparison of the camera obscura and the optics of the eye.

  15. Recognizing patterns of visual field loss using unsupervised machine learning

    NASA Astrophysics Data System (ADS)

    Yousefi, Siamak; Goldbaum, Michael H.; Zangwill, Linda M.; Medeiros, Felipe A.; Bowd, Christopher

    2014-03-01

    Glaucoma is a potentially blinding optic neuropathy that results in a decrease in visual sensitivity. Visual field abnormalities (decreased visual sensitivity on psychophysical tests) are the primary means of glaucoma diagnosis. One form of visual field testing is Frequency Doubling Technology (FDT) that tests sensitivity at 52 points within the visual field. Like other psychophysical tests used in clinical practice, FDT results yield specific patterns of defect indicative of the disease. We used Gaussian Mixture Model with Expectation Maximization (GEM), (EM is used to estimate the model parameters) to automatically separate FDT data into clusters of normal and abnormal eyes. Principal component analysis (PCA) was used to decompose each cluster into different axes (patterns). FDT measurements were obtained from 1,190 eyes with normal FDT results and 786 eyes with abnormal (i.e., glaucomatous) FDT results, recruited from a university-based, longitudinal, multi-center, clinical study on glaucoma. The GEM input was the 52-point FDT threshold sensitivities for all eyes. The optimal GEM model separated the FDT fields into 3 clusters. Cluster 1 contained 94% normal fields (94% specificity) and clusters 2 and 3 combined, contained 77% abnormal fields (77% sensitivity). For clusters 1, 2 and 3 the optimal number of PCA-identified axes were 2, 2 and 5, respectively. GEM with PCA successfully separated FDT fields from healthy and glaucoma eyes and identified familiar glaucomatous patterns of loss.

  16. Evaluation of ocular irritancy of coal-tar dyes used in cosmetics employing reconstructed human cornea-like epithelium and short time exposure tests.

    PubMed

    Lee, Miri; Nam, Ki Taek; Kim, Jungah; Lim, Song E; Yeon, Sang Hyeon; Lee, Buhyun; Lee, Joo Young; Lim, Kyung-Min

    2017-10-01

    Coal-tar dyes in cosmetics may elicit adverse effects in the skin and eyes. Countries, like the US, have banned the use of coal-tar dyes in cosmetics for the eye area due to the potential for ocular irritation. We evaluated the eye irritation potential of 15 coal-tar dyes permitted as cosmetic ingredients in reconstructed human cornea-like epithelium (RhCEs [EpiOcular™ and MCTT HCE™]) tests and the short time exposure (STE) test. Eosin YS, phloxine B, tetrachlorotetrabromofluorescein, and tetrabromofluorescein were identified as irritants in RhCEs; dibromofluorescein and uranine yielded discrepant results. STE enabled further classification in accordance with the UN Globally Harmonized System of Classification and Labelling of Chemicals, as follows: eosin YS as Cat 2; phloxine B, Cat 1; and tetrachlorotetrabromofluorescein and tetrabromofluorescein, Cat 1/2. STE indicated dibromofluorescein (irritant in EpiOcular™) and uranine (irritant in MCTT HCE™) as No Cat, resulting in the classification of "No prediction can be made." based on bottom-up approach with each model. These results demonstrated that in vitro eye irritation tests can be utilized to evaluate the potential ocular irritancy of cosmetic ingredients and provide significant evidence with which to determine whether precautions should be given for the use of coal-tar dyes in cosmetics or other substances applied to the eye area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Evaluation of retinoic acid ophthalmic emulsion in dry eye.

    PubMed

    Selek, H; Unlü, N; Orhan, M; Irkeç, M

    2000-01-01

    An oil in water emulsion of 0.01% all-trans-retinoic acid (tretinoin) was prepared and clinically evaluated in dry eye patients. The ophthalmic emulsion consisted of 10% of arachis oil and 90% of the hydrogel of Carbopol 940. To evaluate retinoic acid emulsion clinically, a placebo-controlled, open-labeled, randomized study was performed with 22 dry-eye patients. Symptoms were recorded before and after the treatments. The Schirmer I test, measurement of tear film break-up time (BUT), rose Bengal and fluorescein staining of cornea and conjunctiva, and mucus fern test were done. Retinoic acid did not improve the dryness, photophobia and foreign body sensation more than placebo. Schirmer test and BUT were significantly improved by retinoic acid treatment. Corneal and conjunctival epithelium maintained their characteristics during the use of retinoic acid, as indicated by rose Bengal and fluorescein staining. Ophthalmic emulsion of retinoic acid can be suggested as a promising approach for the treatment of dry eye.

  18. Characterization of iris pattern stretches and application to the measurement of roll axis eye movements.

    PubMed

    Nishiyama, Junpei; Hashimoto, Tsutomu; Sakashita, Yusuke; Fujiyoshi, Hironobu; Hirata, Yutaka

    2008-01-01

    Eye movements are utilized in many scientific studies as a probe that reflects the neural representation of 3 dimensional extrapersonal space. This study proposes a method to accurately measure the roll component of eye movements under the conditions in which the pupil diameter changes. Generally, the iris pattern matching between a reference and a test iris image is performed to estimate roll angle of the test image. However, iris patterns are subject to change when the pupil size changes, thus resulting in less accurate roll angle estimation if the pupil sizes in the test and reference images are different. We characterized non-uniform iris pattern contraction/expansion caused by pupil dilation/constriction, and developed an algorithm to convert an iris pattern with an arbitrary pupil size into that with the same pupil size as the reference iris pattern. It was demonstrated that the proposed method improved the accuracy of the measurement of roll eye movement by up to 76.9%.

  19. Technical Report of the Use of a Novel Eye Tracking System to Measure Impairment Associated with Mild Traumatic Brain Injury

    PubMed Central

    2017-01-01

    This technical report details the results of an uncontrolled study of EyeGuide Focus, a 10-second concussion management tool which relies on eye tracking to determine the potential impairment of visual attention, an indicator often of mild traumatic brain injury (mTBI). Essentially, people who can visually keep steady and accurate attention on a moving object in their environment likely suffer from no impairment. However, if after a potential mTBI event, subjects cannot keep attention on a moving object in a normal way as demonstrated on their previous healthy baseline tests. This may indicate possible neurological impairment. Now deployed at multiple locations across the United States, Focus (EyeGuide, Lubbock, Texas, United States) to date, has recorded more than 4,000 test scores. Our data analysis of these results shows the promise of Focus as a low-cost, ocular-based impairment test for assessing potential neurological impairment caused by mTBI in subjects ages eight and older.  PMID:28630809

  20. Technical Report of the Use of a Novel Eye Tracking System to Measure Impairment Associated with Mild Traumatic Brain Injury.

    PubMed

    Kelly, Michael

    2017-05-15

    This technical report details the results of an uncontrolled study of EyeGuide Focus, a 10-second concussion management tool which relies on eye tracking to determine the potential impairment of visual attention, an indicator often of mild traumatic brain injury (mTBI). Essentially, people who can visually keep steady and accurate attention on a moving object in their environment likely suffer from no impairment. However, if after a potential mTBI event, subjects cannot keep attention on a moving object in a normal way as demonstrated on their previous healthy baseline tests. This may indicate possible neurological impairment. Now deployed at multiple locations across the United States, Focus (EyeGuide, Lubbock, Texas, United States) to date, has recorded more than 4,000 test scores. Our data analysis of these results shows the promise of Focus as a low-cost, ocular-based impairment test for assessing potential neurological impairment caused by mTBI in subjects ages eight and older.

  1. Do the Eyes Have It? Using Eye Tracking to Assess Students Cognitive Dimensions

    ERIC Educational Resources Information Center

    Nisiforou, Efi A.; Laghos, Andrew

    2013-01-01

    Field dependence/independence (FD/FI) is a significant dimension of cognitive styles. The paper presents results of a study that seeks to identify individuals' level of field independence during visual stimulus tasks processing. Specifically, it examined the relationship between the Hidden Figure Test (HFT) scores and the eye tracking metrics.…

  2. 46 CFR 402.210 - Requirements and qualifications for registration.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., neurosyphilis, hemiplegia, paralysis or missing arm, leg, or eye, muteness or pronounced speech impairment... one eye and at least 20/40 in the other. An applicant who wears glasses or contact lenses must also pass a test without glasses or lens of at least 20/40 in one eye and at least 20/70 in the other...

  3. A Critical Test of Temporal and Spatial Accuracy of the Tobii T60XL Eye Tracker

    ERIC Educational Resources Information Center

    Morgante, James D.; Zolfaghari, Rahman; Johnson, Scott P.

    2012-01-01

    Infant eye tracking is becoming increasingly popular for its presumed precision relative to traditional looking time paradigms and potential to yield new insights into developmental processes. However, there is strong reason to suspect that the temporal and spatial resolution of popular eye tracking systems is not entirely accurate, potentially…

  4. Saccadic Eye Movements Impose a Natural Bottleneck on Visual Short-Term Memory

    ERIC Educational Resources Information Center

    Ohl, Sven; Rolfs, Martin

    2017-01-01

    Visual short-term memory (VSTM) is a crucial repository of information when events unfold rapidly before our eyes, yet it maintains only a fraction of the sensory information encoded by the visual system. Here, we tested the hypothesis that saccadic eye movements provide a natural bottleneck for the transition of fragile content in sensory memory…

  5. Visual function after strontium-90 plaque irradiation in patients with age-related subfoveal choroidal neovascularization.

    PubMed

    Jaakkola, A; Heikkonen, J; Tarkkanen, A; Immonen, I

    1999-02-01

    To report 2-year visual and angiographic results in eyes treated with strontium plaque irradiation for subfoveal choroidal neovascular membranes (CNVM) in age-related macular degeneration. Twenty eyes with recent subfoveal CNVM were treated with local irradiation. The impact of the treatment on visual function was evaluated by visual acuity, contrast sensitivity and reading speed testing. At 12 months visual acuity had improved or remained the same in 9/ 20 eyes (45%). At 24 months visual acuity was stable in 5/18 eyes (28%). Eyes with signs of CNVM regression (13/18, 72%) lost a mean of 3.3 lines, but eyes with recurrent CNVM lost a mean of 5.1 lines of vision. The mean contrast sensitivity was better in the irradiated eyes than in the fellow eyes with late age-related macular degeneration at 24 months. Six of 17 irradiated eyes (35%) could read at least some words at 24 months. Visual function decreases in patients treated with strontium irradiation, but less in eyes showing regression of the CNVM than in eyes with further growth of the CNVM.

  6. Comparison of eye imaging pattern recognition using neural network

    NASA Astrophysics Data System (ADS)

    Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.

    2015-05-01

    The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.

  7. Multifocal VEP and OCT findings in patients with primary open angle glaucoma: A cross-sectional study

    PubMed Central

    2012-01-01

    Bakground To evaluate objectively the anatomical and functional changes of optic nerve in eyes with primary open angle glaucoma (POAG) by the joint use of optical coherence tomography (OCT) and multifocal visual evoked potentials (mfVEP). Methods 29 eyes with open angle glaucoma and visual field defects, as well as 20 eyes of 10 age-matched control normal subjects were tested. All participants underwent a complete ophthalmological examination. Moreover, Humphrey visual field test, OCT examination and recording of mfVEP were performed. Amplitude and implicit time of mfVEP, as well as RNFL thickness were measured. Differences in density components of mfVEP and in RNFL thickness among POAG eyes and control eyes were examined using Student’s t-test. Results In glaucomatous eyes the mean Retinal Response Density (RRD) was lower than normal in ring 1, 2 and 3 of mfVEP (p < 0.0001). Specifically the mean amplitude of mfVEP in POAG eyes was estimated at 34.2 ± 17.6 nV/deg2, 6.9 ± 4.8 nV/deg2 and 2.6 ± 1.6 nV/deg2 in rings 1, 2 and 3 respectively. In contrast the mean implicit time was similar to control eyes. In addition, the mean RNFL thickness in POAG eyes was estimated at 76.8 ± 26.6 μm in the superior area, 52.1 ± 16.3 μm in the temporal area, 75.9 ± 32.5 μm in the inferior area and 58.6 ± 19.4 μm in the nasal area. There was a statistically significant difference in RNFL thickness in all peripapillary areas (p < 0.0001) between POAG eyes and controls, with superior and inferior area to present the highest decrease. Conclusions Our study shows that, although Standard Automatic Perimetry is the gold standard to evaluate glaucomatous neuropathy, the joint use of mfVEP and OCT could be useful in better monitoring glaucoma progression. PMID:22856337

  8. Principles of operation, accuracy and precision of an Eye Surface Profiler.

    PubMed

    Iskander, D Robert; Wachel, Pawel; Simpson, Patrick N D; Consejo, Alejandra; Jesus, Danilo A

    2016-05-01

    To introduce a newly developed instrument for measuring the topography of the anterior eye, provide principles of its operation and to assess its accuracy and precision. The Eye Surface Profiler is a new technology based on Fourier transform profilometry for measuring the anterior eye surface encompassing the corneo-scleral area. Details of technical principles of operation are provided for the particular case of sequential double fringe projection. Technical limits of accuracy have been assessed for several key parameters such as the carrier frequency, image quantisation level, sensor size, carrier frequency inaccuracy, and level and type of noise. Further, results from both artificial test surfaces as well as real eyes are used to assess precision and accuracy of the device (here benchmarked against one of popular Placido disk videokeratoscopes). Technically, the Eye Surface Profiler accuracy can reach levels below 1 μm for a range of considered key parameters. For the unit tested and using calibrated artificial surfaces, the accuracy of measurement (in terms of RMS error) was below 10 μm for a central measurement area of 8 mm diameter and below 40 μm for an extended measurement area of 16 mm. In some cases, the error reached levels of up to 200 μm at the very periphery of the measured surface (up to 20 mm). The SimK estimates of the test surfaces from the Eye Surface Profiler were in close agreement with those from a Placido disk videokeratoscope with differences no greater than ±0.1 D. For real eyes, the benchmarked accuracy was within ±0.5D for both the spherical and cylindrical SimK components. The Eye Surface Profiler can successfully measure the topography of the entire anterior eye including the cornea, limbus and sclera. It has a great potential to become an optometry clinical tool that could substitute the currently used videokeratoscopes and provide a high quality corneo-scleral topography. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  9. Studies of the vestibulo-ocular reflex on STS 4, 5 and 6

    NASA Technical Reports Server (NTRS)

    Thornton, William E.; Pool, Sam L.; Moore, Thomas P.; Uri, John J.

    1988-01-01

    The vestibulo-ocular reflex (VOR) may be altered by weightlessness. Since this reflex plays a large role in visual stabilization, it was important to document any changes caused by space flight. This is a report on findings on STS-4 through 6 and is part of a larger study of neurosensory adaptation done on STS-4 through 8. Voluntary horizontal head oscillations at 1/3 Hz with amplitude of 30 deg right and left of center were recorded by a potentiometer and compared to eye position recorded by electroculography under the following conditions: eyes open, head fixed, tracking horizontal targets switched 0, 15, and 30 degrees right and left (optokinetic reflex - OKR - and calibration); eyes open and fixed on static external target with oscillation, (vestibulo ocular reflex, eyes closed - VOR EC); eyes open and wearing opaque goggles with target fixed in imagination (vestibulo-ocular reflex, eyes shaded - VOR ES); and eyes open and fixed on a head synchronized target with head oscillation (VOR suppression). No significant changes were found in voluntary head oscillation frequency or amplitude in those with (n=5), and without (n=3), space motion sickness (SMS), with phase of flight or test condition. Variations in head oscillation were too small to have produced detectable changes in test results.

  10. Objective evaluation of the visual acuity in human eyes

    NASA Astrophysics Data System (ADS)

    Rosales, M. A.; López-Olazagasti, E.; Ramírez-Zavaleta, G.; Varillas, G.; Tepichín, E.

    2009-08-01

    Traditionally, the quality of the human vision is evaluated by a subjective test in which the examiner asks the patient to read a series of characters of different sizes, located at a certain distance of the patient. Typically, we need to ensure a subtended angle of vision of 5 minutes, which implies an object of 8.8 mm high located at 6 meters (normal or 20/20 visual acuity). These characters constitute what is known as the Snellen chart, universally used to evaluate the spatial resolution of the human eyes. The mentioned process of identification of characters is carried out by means of the eye - brain system, giving an evaluation of the subjective visual performance. In this work we consider the eye as an isolated image-forming system, and show that it is possible to isolate the function of the eye from that of the brain in this process. By knowing the impulse response of the eye´s system we can obtain, in advance, the image of the Snellen chart simultaneously. From this information, we obtain the objective performance of the eye as the optical system under test. This type of results might help to detect anomalous situations of the human vision, like the so called "cerebral myopia".

  11. Evaluation of eye injury risk from projectile shooting toys using the focus headform - biomed 2009.

    PubMed

    Bisplinghoff, Jill A; Duma, Stefan M

    2009-01-01

    Half of eye injuries in the United States are caused by a blunt impact and more specifically, eye injuries effecting children often result from projectile shooting toys. The purpose of this study is to evaluate the risk of eye injuries of currently available projectile shooting toys. In order to assess the risk of each toy, a Facial and Ocular Countermeasure Safety (FOCUS) headform was used to measure the force applied to the eye during each hit for a total of 18 tests. The selected toys included a dart gun, a foam launcher, and a ball launcher. The force ranged from 4-93 N and was analyzed using the injury risk function for globe rupture for the FOCUS headform. Projectile characteristics were also examined using normalized energy to determine risk of corneal abrasion, hyphema, lens dislocation, retinal damage and globe rupture. It was found that the three toys tested produced peak loads corresponding with risk of globe rupture between 0% and 17.3%. The normalized energy results show no risk of hyphema, lens dislocation, retinal damage or globe rupture and a maximum risk of corneal abrasion of 5.9%. This study concludes that although there are many eye injuries caused by projectiles, the selected toys show a very low risk of eye injury.

  12. Eye center localization and gaze gesture recognition for human-computer interaction.

    PubMed

    Zhang, Wenhao; Smith, Melvyn L; Smith, Lyndon N; Farooq, Abdul

    2016-03-01

    This paper introduces an unsupervised modular approach for accurate and real-time eye center localization in images and videos, thus allowing a coarse-to-fine, global-to-regional scheme. The trajectories of eye centers in consecutive frames, i.e., gaze gestures, are further analyzed, recognized, and employed to boost the human-computer interaction (HCI) experience. This modular approach makes use of isophote and gradient features to estimate the eye center locations. A selective oriented gradient filter has been specifically designed to remove strong gradients from eyebrows, eye corners, and shadows, which sabotage most eye center localization methods. A real-world implementation utilizing these algorithms has been designed in the form of an interactive advertising billboard to demonstrate the effectiveness of our method for HCI. The eye center localization algorithm has been compared with 10 other algorithms on the BioID database and six other algorithms on the GI4E database. It outperforms all the other algorithms in comparison in terms of localization accuracy. Further tests on the extended Yale Face Database b and self-collected data have proved this algorithm to be robust against moderate head poses and poor illumination conditions. The interactive advertising billboard has manifested outstanding usability and effectiveness in our tests and shows great potential for benefiting a wide range of real-world HCI applications.

  13. Filtration by eyelashes

    NASA Astrophysics Data System (ADS)

    Vistarakula, Krishna; Bergin, Mike; Hu, David

    2010-11-01

    Nearly every mammalian and avian eye is rimmed with lashes. We investigate experimentally the ability of lashes to reduce airborne particle deposition in the eye. We hypothesize that there is an optimum eyelash length that maximizes both filtration ability and extent of peripheral vision. This hypothesis is tested using a dual approach. Using preserved heads from 36 species of animals at the American Museum of Natural History, we determine the relationship between eye size and eyelash geometry (length and spacing). We test the filtration efficacy of these geometries by deploying outdoor manikins and measuring particle deposition rate as a function of eyelash length.

  14. Vision Test in Seconds

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Acuity Systems, Inc. developed an electro-optical instrument under a grant from NASA to measure the visual performance of pilots. Transferred from Ames Research Center, this instrument now allows you to have your eyes tested in seconds by relatively unskilled operators. The device automatically measures refractive error of eye and prints out proper prescription for glasses. The unit also detects cataracts and glaucoma.

  15. Brief Report: Eye-Movement Patterns during an Embedded Figures Test in Children with ASD

    ERIC Educational Resources Information Center

    Keehn, Brandon; Brenner, Laurie A.; Ramos, Aurora I.; Lincoln, Alan J.; Marshall, Sandra P.; Muller, Ralph-Axel

    2009-01-01

    The present study examined fixation frequency and duration during an Embedded Figures Test (EFT) in an effort to better understand the attentional and perceptual processes by which individuals with autism spectrum disorder (ASD) achieve accelerated EFT performance. In particular, we aimed to elucidate differences in the patterns of eye-movement in…

  16. Intentional Response Distortion on Personality Tests: Using Eye-Tracking to Understand Response Processes when Faking

    ERIC Educational Resources Information Center

    van Hooft, Edwin A. J.; Born, Marise Ph.

    2012-01-01

    Intentional response distortion or faking among job applicants completing measures such as personality and integrity tests is a concern in personnel selection. The present study aimed to investigate whether eye-tracking technology can improve our understanding of the response process when faking. In an experimental within-participants design, a…

  17. Exploration and comparison of in vitro eye irritation tests with the ISO standard in vivo rabbit test for the evaluation of the ocular irritancy of contact lenses.

    PubMed

    Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min

    2016-12-01

    In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.

  18. Evaluation of the Commercial, Off-the-Shelf (COTS) King-Devick Eye Tracking System

    DTIC Science & Technology

    duty decisions. The current literature suggests that the King Devick (KD) number reading test is a sensitive screener for concussion sustained during...sports activities. The KD test involves timing an individual reading aloud 120 single digit numbers, without error, printed on three standard cards...timing is performed with a stopwatch. The extensive literature commonly describes the KD test as revealing the disruption of eye movements that could be

  19. [Transplantation of autologous labial salivary glands for severe dry eye].

    PubMed

    Luo, Shun-rong; Zou, Liu-he; Yan, Chao; Pan, Zhi-qiang; Liu, Jing-ming; Chen, Zhi-yuan; Yin, Wei-hong

    2013-01-01

    Autologous labial salivary gland transplantation has been a promising alternative for the treatment of severe dry eye. In this article, we describe the results of the ocular surface changes after labial salivary gland transplantation and investigate the feasibility of this treatment. The results of this technique in 8 patients (eyes) who suffered from severe dry eye were prospectively analyzed after surgery (follow-up of 6 months). The best-corrected visual acuity, Schirmer I test, degree of discomfort, usage of pharmaceutical tear substitutes, tear interferometry and slit lamp examination were investigated at different time before and after surgery. All grafts remained viable and the survival rate is 100%. All patients showed significant increase in the Schirmer's test and they expressed great improvement in their ocular discomfort. The use of artificial tear substitutes was reduced because of the increased ocular surface lubrication. Although the authors' long-term experience still is limited, we believe that the procedure is a promising alternative approach for severe dry eye.

  20. An unusual cause of central retinal artery occlusion: acquired immunodeficiency syndrome.

    PubMed

    Erdol, H; Turk, A; Caylan, R

    2007-01-01

    In patients with acquired immunodeficiency syndrome (AIDS), disturbances in the circulation of retinal vessels are mostly encountered at the microvascular level. Rarely observed large retinal vessel occlusions frequently affect retinal veins. A 32-year-old woman was admitted to the authors' clinic with sudden loss of vision. Her clinical and ophthalmologic examinations and laboratory tests were carried out and the results were evaluated. The patient's history revealed a diagnosis of AIDS established 5 years ago. Her corrected visual acuity was limited to light perception in the right eye and 20/60 in the left eye. There was afferent pupillary defect in the right eye. Posterior segment examination demonstrated central retinal artery occlusion in the right eye and cotton-wool spots in the left eye. The clinical examination and laboratory test results did not reveal any comorbid disease state that can contribute to this presentation. As thrombi may develop in patients with human immunodeficiency virus infection, they should be closely followed up for the development of vasoocclusive disease.

  1. The Advanced Glaucoma Intervention Study (AGIS): 14. Distinguishing progression of glaucoma from visual field fluctuations.

    PubMed

    Kim, Jonghyeon; Dally, Leonard G; Ederer, Fred; Gaasterland, Douglas E; VanVeldhuisen, Paul C; Blackwell, Beth; Sullivan, E Kenneth; Prum, Bruce; Shafranov, George; Beck, Allen; Spaeth, George L

    2004-11-01

    To determine the least worsening of a visual field (VF) and the least number of confirming tests needed to identify progression of glaucomatous VF defects. Cohort study of participants in a clinical trial. Seven hundred fifty-two eyes of 565 patients with advanced glaucoma. Visual field tests were quantified with the Advanced Glaucoma Intervention Study (AGIS) VF defect score and the Humphrey Field Analyzer mean deviation (MD). Follow-up was 8 to 13 years. Two measures based on the AGIS VF defect score: (1) sustained decrease of VF (SDVF), a worsening from baseline by 2 (alternatively, 3 or 4) or more units and sustained for 2 (alternatively, 3) consecutive 6-month visits and (2) after the occurrence of SDVF, the average percent of eyes with worsening by 2 (alternatively, 3 or 4) or more units from baseline. Two similar measures based on MD. Based on the original AGIS criteria for SDVF (a worsening of 4 units in the AGIS score sustained during 3 consecutive 6-month visits), 31% of eyes had an SDVF. The percent of eyes with a sustained event increases by approximately 10% when either the minimum number of units of field loss or the minimum number of 6-month visits during which the loss is sustained decreases by 1. During 3 years of follow-up after a sustained event, a worsening of at least 2 units was found in 72% of eyes that had a 2-visit sustained event. The same worsening was found in 84% of eyes that had a 3-visit sustained event. Through the next 10 years after a sustained event, based on worsening of 2, 3, or 4 units at 2 or 3 consecutive tests, the loss reoccurred, on average, in >/=75% of study eyes. Results for MD are similar. In patients with advanced glaucoma, a single confirmatory test 6 months after a VF worsening indicates with at least 72% probability a persistent defect when the worsening is defined by at least 2 units of AGIS score or by at least 2 decibels of MD. When the number of confirmatory tests is increased from 1 to 2, the percentage of eyes that show a persistent defect increases from 72% to 84%.

  2. Effectiveness and relevant factors of 2% rebamipide ophthalmic suspension treatment in dry eye.

    PubMed

    Ueda, Kaori; Matsumiya, Wataru; Otsuka, Keiko; Maeda, Yoshifumi; Nagai, Takayuki; Nakamura, Makoto

    2015-06-06

    Rebamipide with mucin secretagogue activity was recently approved for the treatment of dry eye. The efficacy and safety in the treatment of rebamipide were shown in two pivotal clinical trials. It was the aim of this study to evaluate the effect of 2% rebamipide ophthalmic suspension in patients with dry eye and analyze relevant factors for favorable effects of rebamipide in clinical practice. This was a retrospective cohort study of 48 eyes from 24 patients with dry eye treated with 2% rebamipide ophthalmic suspension. Dry eye-related symptom score, tear film break-up time (TBUT), fluorescein ocular surface staining score (FOS) and the Schirmer test were used to collect the data from patients at baseline, and at 2, 4, 8, and 12 week visits. To determine the relevant factors, multiple regression analyses were then performed. Mean dry eye-related symptom score showed a significant improvement from the baseline (14.5 points) at 2, 4, 8 and 12 weeks (9.80, 7.04, 7.04 and 7.83 points, corrected P value < 0.001, respectively). Median FOS showed a significant improvement from the baseline (3.0 points) at 2, 4, 8 and 12 weeks (2.0, 2.0, 1.0 and 1.0 points, corrected P value < 0.001, respectively). TBUT and Schirmer test values were not significantly improved after the treatment. For ocular symptoms, three parameters (foreign body sensation, dry eye sensation and ocular discomfort) showed significant improvements at all visits. The multiple regression analyses showed that the fluorescein conjunctiva staining score was significantly correlated with the changes of dry eye-related symptom score at 12 weeks (P value = 0.017) and dry eye-related symptom score was significantly correlated with independent variables for the changes of FOS at 12 weeks (P value = 0.0097). Two percent rebamipide ophthalmic suspension was an effective therapy for dry eye patients. Moreover the fluorescein conjunctiva staining score and dry eye-related symptom score might be good relevant factors for favorable effects of rebamipide.

  3. The Use of the Esclera Scleral Contact Lens in the Treatment of Moderate to Severe Dry Eye Disease.

    PubMed

    La Porta Weber, Sarah; Becco de Souza, Rodrigo; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2016-03-01

    To evaluate the efficacy of the Esclera scleral contact lens (SCL) treatment and its impact on clinical testing for moderate to severe dry eye disease (DED). Prospective interventional case series. A total of 41 eyes from 25 patients with moderate to severe DED were evaluated for the Esclera SCL treatment. Best-corrected visual acuity (BCVA), tear osmolarity, the Schirmer I test, tear film breakup time (TBUT), corneal and conjunctival staining, meibomian grading, and Ocular Surface Disease Index and SF-36v2 questionnaires were assessed before and after the SCL treatment. These values were compared to assess the real benefit of using SCL as a treatment for DED. Forty-one eyes from 25 patients were fitted with SCL for management of DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren syndrome (11 eyes), graft-vs-host disease (2 eyes), dry eye after keratomileusis in situ (2 eyes), and undifferentiated ocular surface disease (4 eyes). BCVA improved from 0.703 ± 0.55 logMAR with habitual correction to 0.406 ± 0.43 logMAR with SCL (P < .001). There was a significant decrease in tear osmolarity values (338.1 ± 27.1 to 314.25 ± 38.8 mOsm/L, P < .001) and van Bijsterveld scores (3.63 ± 2.33 to 2.63 ± 2.46 grade, P = .015) between the baseline and 12 months after SCL wear. There were also significant improvements in dry eye symptoms and quality of life as assessed by the OSDI and SF-36v2 questionnaires (both with P < .001). The Esclera SCL treatment had a positive impact on tear osmolarity and van Bijsterveld score, as well as an improvement in the patients' BCVA, dry eye symptoms, and quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Combination Therapy of Intense Pulsed Light Therapy and Meibomian Gland Expression (IPL/MGX) Can Improve Dry Eye Symptoms and Meibomian Gland Function in Patients With Refractory Dry Eye: A Retrospective Analysis.

    PubMed

    Vegunta, Sravanthi; Patel, Dharmendra; Shen, Joanne F

    2016-03-01

    To assess the improvement in meibomian gland function and dry eye symptoms in patients with refractory dry eye treated with a combination therapy of intense pulsed light (IPL) and meibomian gland expression (MGX). Medical records of 81 consecutive patients with dry eye treated with serial IPL/MGX were retrospectively examined to determine the outcome. All patients had a minimum of 6 months of follow-up after the first IPL/MGX treatment. Patients typically received 1 to 4 IPL treatments spaced 4 to 6 weeks apart. Each IPL session included MGX. Thirty-five charts had complete data for inclusion in analysis. We reviewed demographics, ocular histories, Standard Patient Evaluation of Eye Dryness 2 (SPEED2) symptom survey scores, slit-lamp examinations, and meibomian gland evaluations (MGE) at baseline and at each visit before IPL/MGX treatments. The paired t test showed a significant (P < 0.0001) decrease in SPEED2 with IPL/MGX therapy. Of the 35 patients, 8 (23%) had a ≥50% decrease in SPEED2, 23 (66%) had a 1% to 49% decrease in SPEED2, 1 (3%) had no change in SPEED2, and 3 (9%) had an increase in SPEED2. The Paired t test showed a significant increase in MGE in the left eye but not in the right eye (OD P = 0.163 and OS P = 0.0002). Thirteen patients (37%) had improved MGE bilaterally. Eight patients (23%) had either a decrease in MGE bilaterally or a decrease in 1 eye with no change in the other eye. This retrospective analysis shows that the combination of IPL and MGX can significantly improve dry eye symptoms (in 89% of patients) and meibomian gland function (in 77% of patients in at least 1 eye).

  5. Robust Eye Center Localization through Face Alignment and Invariant Isocentric Patterns

    PubMed Central

    Teng, Dongdong; Chen, Dihu; Tan, Hongzhou

    2015-01-01

    The localization of eye centers is a very useful cue for numerous applications like face recognition, facial expression recognition, and the early screening of neurological pathologies. Several methods relying on available light for accurate eye-center localization have been exploited. However, despite the considerable improvements that eye-center localization systems have undergone in recent years, only few of these developments deal with the challenges posed by the profile (non-frontal face). In this paper, we first use the explicit shape regression method to obtain the rough location of the eye centers. Because this method extracts global information from the human face, it is robust against any changes in the eye region. We exploit this robustness and utilize it as a constraint. To locate the eye centers accurately, we employ isophote curvature features, the accuracy of which has been demonstrated in a previous study. By applying these features, we obtain a series of eye-center locations which are candidates for the actual position of the eye-center. Among these locations, the estimated locations which minimize the reconstruction error between the two methods mentioned above are taken as the closest approximation for the eye centers locations. Therefore, we combine explicit shape regression and isophote curvature feature analysis to achieve robustness and accuracy, respectively. In practical experiments, we use BioID and FERET datasets to test our approach to obtaining an accurate eye-center location while retaining robustness against changes in scale and pose. In addition, we apply our method to non-frontal faces to test its robustness and accuracy, which are essential in gaze estimation but have seldom been mentioned in previous works. Through extensive experimentation, we show that the proposed method can achieve a significant improvement in accuracy and robustness over state-of-the-art techniques, with our method ranking second in terms of accuracy. According to our implementation on a PC with a Xeon 2.5Ghz CPU, the frame rate of the eye tracking process can achieve 38 Hz. PMID:26426929

  6. A Study on Hospital Admissions For Eye Trauma in Kashan, Iran.

    PubMed

    Movahedinejad, Tayebeh; Adib-Hajbaghery, Mohsen; Zahedi, Mohammad Reza

    2016-05-01

    Eye trauma is among the most common reasons for referral to hospital emergency departments and ophthalmologists' offices. It also is a common cause of vision loss worldwide. However, few studies are available on the changes in the epidemiology of eye trauma in Iran in recent years. This study aimed to investigate the characteristics of hospital admissions for eye trauma in Kashan from August 2011 to February 2014. A cross-sectional study was carried out on the hospital records of all patients with eye trauma who were admitted to Kashan's Matini hospital between August 2011 and February 2014. Having an eye trauma and being hospitalized for at least one day was selected as the criteria for inclusion in the study. The data were then recorded on a checklist devised by the researcher. After entering the data into the SPSS software, descriptive statistics (i.e., percentage, frequency, mean, and standard deviation) were calculated for all variables. Chi-square, Fisher's exact test, and Mann-Whitney U test were used to analyze the data. In total, 200 patients with eye trauma had been hospitalized in Matini Hospital between August 2011 and February 2014. Of these patients, 86% were males, 40% were in the age range of 20-39 years, 68% lived in urban areas, and 21% of those in employment were manual and industrial workers. Approximately 38.5% of eye traumas had occurred in the work place; 72.5% of patients had penetrating injuries and 98% of cases were injured in one eye. More injuries occurred in the cornea (25.5%) than elsewhere in the eye, and 75.5% of patients were treated surgically. Among all variables, only the type of trauma (P = 0.009) and cause of trauma (P = 0.004) were significantly related to the patients' gender. Eye trauma was prevalent among males, young people, urban residents, and manual and industrial workers. As the eyes play a vital role in daily life, communication, and work activities, and eye health is so important for individuals to attain high educational status and productivity, the public should be thoroughly educated about eye protection and the use of safety measures, especially in occupational activities.

  7. [Ultrasonographic findings in ocular toxocariasis].

    PubMed

    Morais, Fábio Barreto; Maciel, Ana Lúcia; Arantes, Tiago Eugênio Farias e; Muccioli, Cristina; Allemann, Norma

    2012-01-01

    To evaluate ophthalmic ultrasound findings in the three presentation forms of ocular toxocariasis (peripheral or posterior pole granulomas and chronic endophthalmitis), in patients with confirmed diagnosis of ocular toxocariasis. 11 patients (11 eyes) with clinical and confirmed diagnosis of active ocular toxocariasis, presented positive ELISA test, were analyzed, prospectively, in the study. The patients were submitted to an ocular ultrasound examination (10-MHz transducer, contact technique). In the series of 11 patients, mean age was 7.9 years-old (range from 2 to 17 y), 73% male, referring previous contact with dogs (91%), and with the soil (50%), no referral of appetite perversion. In the analyses of compromised eyes (11 eyes), the ophthalmoscopic examination revealed the following distribution of the 3 forms of ocular toxocariasis: 7 cases (63.6%), posterior pole granuloma; 1 (9.1%), chronic endophthalmitis; 2 (18.2%), peripheral granuloma; and 1 (9.1%), posterior pole granuloma associated with chronic endophthalmitis. Visual acuity impairment: no light perception (3 eyes, 27.3%); hand motion (4 eyes, 36.4%); counting fingers at 10 cm (1 eye, 9.1%); 20/200 (1 eye, 9.1%); 20/70 (1 eye, 9.1%); undefined (1 eye, 9.1%). Serology was positive to Toxocara canis (ELISA test) in 100% of the cases. Ophthalmoscopy was difficult or impossible in 64% of the cases due to the media opacity. Ultrasound findings noted were vitreous membranes with retinal attachment (100%); parietal lesions (granulomas) with high (80%) or medium (20%) reflectivity. The most consistent ultrasound finding in the eye with toxocariasis was a high-reflectivity retinal mass, located in posterior pole or periphery, which may be calcified, and which has as main characteristic the adherence of vitreous membranes. In addition to clinical history, systemic evaluation and serology, the ultrasound can help in the diagnosis of ocular toxocariasis, especially in media opacities.

  8. Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, Chelsea; Lindsay, Clay; Unick, Nick

    Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generatedmore » by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.« less

  9. The application of autologous serum eye drops in severe dry eye patients; subjective and objective parameters before and after treatment.

    PubMed

    Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera

    2014-01-01

    To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p < 0.01) and tear film debris (p < 0.05). The densities of goblet (p < 0.0001) and epithelial cells (p < 0.05) were significantly increased, indicating a decrease of squamous metaplasia after AS treatment. A significant decrease (p < 0.05) was found in the number of apoptotic, HLA-DR-positive and snake-like chromatin cells on the ocular surface. A significant improvement was found in all evaluated subjective symptoms. Altogether, the clinical results were improved in 77%, the laboratory results in 75% and the subjective feelings in 63% of the eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.

  10. Analysis on sports and recreation activity-related eye injuries presenting to the Emergency Department

    PubMed Central

    Moon, Sungbae; Ryoo, Hyun Wook; Ahn, Jae Yun; Park, Jung Bae; Seo, Kang Suk; Shin, Sang Do; Song, Kyoung Jun; Lee, Kang Hyun; Yoo, In Sool; Cho, Jin Seong; Ryu, Hyun Ho; Jeong, Tae Oh; Yeom, Seok Ran; Kim, Young Taek; Hong, Sung Ok

    2016-01-01

    AIM To investigate the incidence and general characteristics of sports-related eye injuries in patients visiting the Emergency Department. METHODS A cross-sectional, multi-center, observational study. Patients with an injured eye who visited the Emergency Department at one of nine hospitals in Korea were enrolled. All data were prospectively collected between March and September 2010 using a questionnaire. Eye injuries that occurred during risky sports were examined by gender and age. Additionally, the rate of open globe injuries that occurred with and without protective eyewear was examined for each activity. Continuous variables were compared using Student's t-test and categorical variables were compared using Chi-square test. RESULTS A total of 446 patients had sports-related eye injuries. Teenagers (10-19 years old) and young adults (20-29 years old) had the most eye injuries. Eye injuries accounted for 0.2% of Emergency Department patients. Baseball was the most common cause of sports-related eye injuries, followed by soccer and hiking. Protective gear was worn by 9.4% of all patients. Patients that were 30-39 years of age had the highest rate of protective gear use, followed by patients that were 40-49 years of age. The proportion of sports-related eye injuries that were open-globe injuries was highest for soccer and hiking. CONCLUSION Although injuries were most common in patients below the age of 10 years, these patients had the lowest rate of protective eyewear use. Injuries in adults over 40 years of age most commonly occurred during hiking, but the rate of protective eyewear use was low. Young athletes should be educated on and provided with protective eyewear and policies protective gear use should be established. For older adults, eye protection should be encouraged, especially during hiking. PMID:27803871

  11. High-resolution imaging of retinal nerve fiber bundles in glaucoma using adaptive optics scanning laser ophthalmoscopy.

    PubMed

    Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa

    2013-05-01

    To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Effects of silicone hydrogel contact lenses on ocular surface after Sub-Bowman's Keratomileusis.

    PubMed

    Gao, Shaohui; Wu, Junshu; Li, Lili; Wang, Yong; Zhong, Xingwu

    2013-11-01

    To evaluate the efficacy of silicone hydrogel contact lenses on ocular surface after Sub-Bowman Keratomileusis (SBK). Forty-six patients suffered from myopia underwent a bilateral SBK. Post-operatively, one eye of each patient wore a PureVision contact lens for 24 h as a treated eye and the contralateral eye was as a blank control. Afterwards, corneal fluorescein (FL) staining, tear break-up time (TBUT), schirmer I test (SIT), central corneal thickness (CCT), ocular surface disease index (OSDI), corneal hysteresis (CH), corneal resistance factor (CRF) and corneal flap complications were assessed 1 d (except for CH and CRF), 1 week, 1 month and 3 months postoperatively. Following SBK, in contrast to the control, corneal fluorescein staining of treated eyes were significantly reduced and tear break-up time of treated eyes were significantly improved at 1 d and 1 week after SBK. However, Schirmer I test of treated and control eyes were not different after SBK. Central corneal thickness of treated eyes were significantly thinner than that of control at 1 d after SBK, however, there were no differences at other time points. Ocular surface disease index of treated eyes were obviously alleviated more than that of control at 1 d after SBK, but no differences were found at other visits. Moreover, Corneal hysteresis and corneal resistance factor of treated and un-treated eyes were not different after surgery. And also the rate of corneal flap complications were not different between treated and control eyes after SBK. Silicone hydrogel contact lenses played a positive role in accelerating corneal epithelial healing, enhancing tear film stability and reducing discomfort of patients in the early stage after SBK.

  13. Prospective Randomized Trial Comparing Efficacy of Topical Loteprednol Etabonate 0.5% Versus Cyclosporine-A 0.05% for Treatment of Dry Eye Syndrome Following Hematopoietic Stem Cell Transplantation.

    PubMed

    Boynton, Grace E; Raoof, Duna; Niziol, Leslie M; Hussain, Munira; Mian, Shahzad I

    2015-07-01

    To evaluate the safety and efficacy of topical loteprednol etabonate (LE) 0.5% compared with cyclosporine A (CsA) 0.05% for the prophylaxis and treatment of dry eye syndrome (DES) after hematopoietic stem cell transplantation (HSCT). Seventy-five patients were randomized to LE (n = 76 eyes of 38 patients) or CsA (n = 74 eyes of 37 patients) pre-HSCT. Lissamine green and fluorescein staining, tear break-up time, tear osmolarity (Osm), Schirmer score (Sch), intraocular pressure, visual acuity, and Ocular Surface Disease Index were assessed pre-HSCT, 3, 6, 9, and 12 months post-HSCT. There were no differences in DES incidence (P = 0.22; log-rank test) or progression (P = 0.41; log-rank test) between the 2 treatment arms during the course of the study. Among eyes with no DES at enrollment, the Kaplan-Meier analysis yielded a 90% rate of DES development in cyclosporine-treated eyes and a 79% rate of DES development in LE-treated eyes by 12 months post-HSCT. The Kaplan-Meier analysis of eyes with DES at enrollment demonstrated a 38% rate of disease progression among cyclosporine-treated eyes and a 26% rate of disease progression among loteprednol-treated eyes by 12 months. No patient in either group had an elevation of 10 mm Hg or greater from baseline at any study visit, and no patients had their treatment discontinued for elevation in intraocular pressure. Pre-HSCT initiation of LE 0.5% appears to be safe and may be as effective as CsA 0.5% for the treatment and prophylaxis of DES following HSCT.

  14. Interactions of cervico-ocular and vestibulo-ocular fast-phase signals in the control of eye position in rabbits.

    PubMed Central

    Barmack, N H; Errico, P; Ferraresi, A; Pettorossi, V E

    1989-01-01

    1. Eye movements in unanaesthetized rabbits were studied during horizontal neck-proprioceptive stimulation (movement of the body with respect to the fixed head), when this stimulation was given alone and when it was given simultaneously with vestibular stimulation (rotation of the head-body). The effect of neck-proprioceptive stimulation on modifying the anticompensatory fast-phase eye movements (AFPs) evoked by vestibular stimulation was studied with a 'conditioning-test' protocol; the 'conditioning' stimulus was a neck-proprioceptive signal evoked by a step-like change in body position with respect to the head and the 'test' stimulus was a vestibular signal evoked by a step rotation of the head-body. 2. The influence of eye position and direction of slow eye movements on the occurrence of compensatory fast-phase eye movements (CFPs) evoked by neck-proprioceptive stimulation was also examined. 3. The anticompensatory fast phase (AFP) evoked by vestibular stimulation was attenuated by a preceding neck-proprioceptive stimulus which when delivered alone evoked compensatory slow-phase eye movements (CSP) in the same direction as the CSP evoked by vestibular stimulation. Conversely, the vestibularly evoked AFP was potentiated by a neck-proprioceptive stimulus which evoked CSPs opposite to that of vestibularly evoked CSPs. 4. Eccentric initial eye positions increased the probability of occurrence of midline-directed compensatory fast-phase eye movements (CFPs) evoked by appropriate neck-proprioceptive stimulation. 5. The gain of the horizontal cervico-ocular reflex (GHCOR) was measured from the combined changes in eye position resulting from AFPs and CSPs. GHCOR was potentiated during simultaneous vestibular stimulation. This enhancement of GHCOR occurred at neck-proprioceptive stimulus frequencies which, in the absence of conjoint vestibular stimulation, do not evoke CSPs. PMID:2795479

  15. Vision loss among diabetics in a group model Health Maintenance Organization (HMO).

    PubMed

    Fong, Donald S; Sharza, Mohktar; Chen, Wansu; Paschal, John F; Ariyasu, Reginald G; Lee, Paul P

    2002-02-01

    To report the management of diabetic retinopathy in one group model health maintenance organization and assess the quality of care. Cross-sectional study. A chart review of 1200 randomly identified patients with diabetes mellitus, continuously enrolled for 3 years in Kaiser Permanente (KP) Southern California, the largest provider of managed care in Southern California, was performed. A total of 1047 patients were included in the analyses. Patient characteristics as well as information from the last eye examination were abstracted. Charts from patients with visual acuity less than 20/200 in their better eye (legal blindness) were selected for extensive chart review to determine the cause of visual loss and the antecedent process of care. T tests or the Wilcoxon rank sum test was used to compare continuous variables. The chi(2) test or the Fisher exact test was used to compare categorical variables. All analyses were performed on the Statistical Analyses System (SAS Institute, North Carolina). Our study population of 1047 diabetic patients was 51.7% male, had a mean age of 60.4 years, a mean duration of diabetes of 9.6 years, and a mean hemoglobin A1c of 8.3%. During the study period, 77.5% of patients received a screening eye examination with examination by an ophthalmologist, an optometrist, or review of a retinal photograph. Of those with a visual acuity assessment (n = 687, 65.6% of 1047), 1.5% had visual acuity of 20/200 or worse (legally blind) in the better eye, while 8.2% had this level of visual acuity in the worse eye. Of eyes with new onset clinically significant macular edema and visual acuity < 20/40, 40% had documentation of focal laser performed within 1 month of diagnosis. Of eyes with vitreous hemorrhage and visual acuity < 20/40, 50% had documentation of vitrectomy. Among eyes that had vitrectomy, over 80% had this procedure within 1 year of diagnosis of vitreous hemorrhage. The current report is the largest study of diabetic retinopathy outcomes among patients enrolled in a prepaid health plan. Further research is necessary to investigate the impact of managed care on health outcomes.

  16. [Effects of acupuncture on lactoferrin content in tears and tear secretion in patients suffering from dry eyes: a randomized controlled trial].

    PubMed

    Shi, Jing-lin; Miao, Wan-hong

    2012-09-01

    With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of treatment, the effect decreased.

  17. Seeing the future: using Xenopus to understand eye regeneration.

    PubMed

    Tseng, Ai-Sun

    2017-01-01

    Studies of Xenopus eye development have contributed considerably to the understanding of vertebrate neurogenesis, including eye field specification, cell fate determination and identification of genes critical for eye formation. This knowledge has served as a solid foundation for cellular and molecular examinations of the robust regenerative capacity of the Xenopus eye. The retina, lens, and the optic nerve are capable of regeneration after injury in both larval and adult stages. Here, we discuss the current models for studying eye regeneration in Xenopus and their potential applications for providing insights into human eye diseases. As Xenopus has many of the same tools that are available for other regeneration models, we thus highlight the distinct strengths and versatility of this organism that make it especially suited for extrapolating and testing strategies aimed at promoting regeneration and repair in eye tissues. Furthermore, we outline a promising future for the use of new techniques and approaches to address outstanding questions in understanding eye regeneration. © 2017 Wiley Periodicals, Inc.

  18. Comparison between Hardy-Rand-Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy.

    PubMed

    Huna-Baron, Ruth; Glovinsky, Yoseph; Habot-Wilner, Zohar

    2013-02-01

    The aim of this work was to compare the specificity-sensitivity balance of the Hardy-Rand-Rittler (HRR) 4th edition with the Ishihara color plate tests for color-vision defects in patients with optic neuropathy. This is a prospective case-control study. The study group included 43 patients (48 eyes) with newly diagnosed optic neuropathy, and the control group included 33 patients (33 right eyes) who were referred to the eye clinic for conditions other than optic nerve or retinal macular disorders. Individuals with visual acuity of less than 20/70 (0.54 Log MAR) were excluded. All patients underwent comprehensive eye examination and color-vision evaluation with both tests in a random order under standardized lighting conditions. The scores of the Ishihara and HRR tests were set as the number of plates identified out of 12 and six respectively. The receiver operating characteristics (ROC) curve was statistically significantly better when using the HRR test (area under curve [AUC] = 0.93 ± 0.03) than for the Ishihara test (AUC = 0.77 ± 0.05) (P = 0.0006). The best specificity-sensitivity balance for the HRR was 100 % and 79 % respectively, and for the Ishihara test 100 % and 48 % respectively. The HRR 4th edition test proved to be superior to the Ishihara test in detecting acquired dyschromatopsia due to optic neuropathy. We recommend using the HRR 4th edition test as a screening method for detection of color-vision defects in patients with optic neuropathy.

  19. Meniere's Disease

    MedlinePlus

    ... are recorded as warm and cool water or air are gently introduced into each ear canal. Since the eyes and ears work in coordination through the nervous system, measurement of eye movements can be used to test ...

  20. Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents.

    PubMed

    Emery, Carolyn A; Cassidy, J David; Klassen, Terry P; Rosychuk, Rhonda J; Rowe, Brian B

    2005-06-01

    There is a need in sports medicine for a static and dynamic standing balance measure to quantify balance ability in adolescents. The purposes of this study were to determine the test-retest reliability of timed static (eyes open) and dynamic (eyes open and eyes closed) unipedal balance measurements and to examine factors associated with balance. Adolescents (n=123) were randomly selected from 10 Calgary high schools. This study used a repeated-measures design. One rater measured unipedal standing balance, including timed eyes-closed static (ECS), eyes-open dynamic (EOD), and eyes-closed dynamic (ECD) balance at baseline and 1 week later. Dynamic balance was measured on a foam surface. Reliability was examined using both intraclass correlation coefficients (ICCs) and Bland and Altman statistical techniques. Multiple linear regressions were used to examine other potentially influencing factors. Based on ICCs, test-retest reliability was adequate for ECS, EOD, and ECD balance (ICC=.69, .59, and .46, respectively). The results of Bland and Altman methods, however, suggest that caution is required in interpreting reliability based on ICCs alone. Although both ECS balance and ECD balance appear to demonstrate adequate test-retest reliability by ICC, Bland and Altman methods of agreement demonstrate sufficient reliability for ECD balance only. Thirty percent of the subjects reached the 180-second maximum on EOD balance, suggesting that this test is not appropriate for use in this population. Balance ability (ECS and ECD) was better in adolescents with no past history of lower-extremity injury. Timed ECD balance is an appropriate and reliable clinical measurement for use in adolescents and is influenced by previous injury.

  1. Predictive performance of the Vitrigel‐eye irritancy test method using 118 chemicals

    PubMed Central

    Yamaguchi, Hiroyuki; Kojima, Hajime

    2015-01-01

    Abstract We recently developed a novel Vitrigel‐eye irritancy test (EIT) method. The Vitrigel‐EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time‐dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel‐EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel‐EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false‐negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false‐positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO‐1, a tight junction‐associated protein and MUC1, a cell membrane‐spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false‐positive chemicals, suggesting that such false‐positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel‐EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel‐EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:26472347

  2. Modulations of eye movement patterns by spatial filtering during the learning and testing phases of an old/new face recognition task.

    PubMed

    Lemieux, Chantal L; Collin, Charles A; Nelson, Elizabeth A

    2015-02-01

    In two experiments, we examined the effects of varying the spatial frequency (SF) content of face images on eye movements during the learning and testing phases of an old/new recognition task. At both learning and testing, participants were presented with face stimuli band-pass filtered to 11 different SF bands, as well as an unfiltered baseline condition. We found that eye movements varied significantly as a function of SF. Specifically, the frequency of transitions between facial features showed a band-pass pattern, with more transitions for middle-band faces (≈5-20 cycles/face) than for low-band (≈<5 cpf) or high-band (≈>20 cpf) ones. These findings were similar for the learning and testing phases. The distributions of transitions across facial features were similar for the middle-band, high-band, and unfiltered faces, showing a concentration on the eyes and mouth; conversely, low-band faces elicited mostly transitions involving the nose and nasion. The eye movement patterns elicited by low, middle, and high bands are similar to those previous researchers have suggested reflect holistic, configural, and featural processing, respectively. More generally, our results are compatible with the hypotheses that eye movements are functional, and that the visual system makes flexible use of visuospatial information in face processing. Finally, our finding that only middle spatial frequencies yielded the same number and distribution of fixations as unfiltered faces adds more evidence to the idea that these frequencies are especially important for face recognition, and reveals a possible mediator for the superior performance that they elicit.

  3. Diagnosing Stroke in Acute Vertigo: The HINTS Family of Eye Movement Tests and the Future of the "Eye ECG".

    PubMed

    Newman-Toker, David E; Curthoys, Ian S; Halmagyi, G Michael

    2015-10-01

    Patients who present to the emergency department with symptoms of acute vertigo or dizziness are frequently misdiagnosed. Missed opportunities to promptly treat dangerous strokes can result in poor clinical outcomes. Inappropriate testing and incorrect treatments for those with benign peripheral vestibular disorders leads to patient harm and unnecessary costs. Over the past decade, novel bedside approaches to diagnose patients with the acute vestibular syndrome have been developed and refined. A battery of three bedside tests of ocular motor physiology known as "HINTS" (head impulse, nystagmus, test of skew) has been shown to identify acute strokes more accurately than even magnetic resonance imaging with diffusion-weighted imaging (MRI-DWI) when applied in the early acute period by eye-movement specialists. Recent advances in lightweight, high-speed video-oculography (VOG) technology have made possible a future in which HINTS might be applied by nonspecialists in frontline care settings using portable VOG. Use of technology to measure eye movements (VOG-HINTS) to diagnose stroke in the acute vestibular syndrome is analogous to the use of electrocardiography (ECG) to diagnose myocardial infarction in acute chest pain. This "eye ECG" approach could transform care for patients with acute vertigo and dizziness around the world. In the United States alone, successful implementation would likely result in improved quality of emergency care for hundreds of thousands of peripheral vestibular patients and tens of thousands of stroke patients, as well as an estimated national health care savings of roughly $1 billion per year. In this article, the authors review the origins of the HINTS approach, empiric evidence and pathophysiologic principles supporting its use, and possible uses for the eye ECG in teleconsultation, teaching, and triage. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Eye-hand preference in schizophrenia: sex differences and significance for hand function.

    PubMed

    Liu, Yi-Chia; Yang, Yen Kuang; Lee, I Hui; Lin, Keh-Chung; Jeffries, Keith J; Lee, Li-Ching

    2004-06-01

    Hand preference and eye dominance were investigated in 73 (30 women, 43 men) schizophrenic patients and 71 (30 women, 41 men) healthy controls. There were significantly more schizophrenic patients and normal controls who were significantly right-hand dominant. However, schizophrenic patients showed a significant excess of left-eye dominance relative to controls (65.8% vs 29.6%; Odds Ratio= 4.75, p< .001). In addition, female schizophrenic patients showed a higher rate of nonright (either left or inconsistent) eye dominance (80%) than male schizophrenic patients (55.8%) and controls (33.3%). Analysis of hand performance on the Purdue Pegboard Test indicated that schizophrenic patients who showed crossed eye-hand dominance scored higher than did patients without crossed eye-hand dominance.

  5. Vestibulo-ocular response and balance control in children and young adults with mild-to-moderate intellectual and developmental disability: a pilot study.

    PubMed

    Zur, Oz; Ronen, Ayelet; Melzer, Itshak; Carmeli, Eli

    2013-06-01

    The vestibulo-ocular response (VOR) may not be fully developed in children with an intellectual and developmental disability (IDD). This study aimed to identify the presence of VOR deficit in children and young adults with unspecified mild-to-moderate intellectual and developmental disability and its effect on balance control. Twenty-one children and young adults with IDD ranging in age from 8 to 22 years (mean 17.5 ± 3.9 years) were included in the study. The VOR was evaluated with the Head Impulse Test and the Static and Dynamic Visual Acuity Test (S&D-VAT). Postural stability was measured in an upright standing position by the Clinical Test for Sensory Interaction in Balance (CTSIB), single leg stance (SLS) during eyes open and eyes closed, and Romberg stance under eyes open and eyes closed conditions using a force platform. Reduced vestibulo-ocular responses were found in 13 of 21 (62%) participants who were able to complete testing. In the fifth condition of the CTSIB (standing on foam with eyes closed), those without VOR deficit were able to maintain balance longer than those with VOR deficit (29 s [median 30] vs. 12s [median 7.3], respectively; p=0.03). The study demonstrates potential effects of VOR deficit in children and young adults with IDD and some significant differences in balance control between those with and without a VOR deficit. VOR function in children and young adults with IDD should be routinely tested to enable early detection of deficits. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Effects of Bilateral Eye Movements on Gist Based False Recognition in the DRM Paradigm

    ERIC Educational Resources Information Center

    Parker, Andrew; Dagnall, Neil

    2007-01-01

    The effects of saccadic bilateral (horizontal) eye movements on gist based false recognition was investigated. Following exposure to lists of words related to a critical but non-studied word participants were asked to engage in 30s of bilateral vs. vertical vs. no eye movements. Subsequent testing of recognition memory revealed that those who…

  7. Impaired Attention to the Eyes of Attachment Figures and the Developmental Origins of Psychopathy

    ERIC Educational Resources Information Center

    Dadds, Mark R.; Jambrak, Jasmin; Pasalich, Dave; Hawes, David J.; Brennan, John

    2011-01-01

    Background: A pervasive failure to attend and respond to emotionally salient stimuli is a core feature of psychopathy. We hypothesise that this begins early in life and is expressed most importantly as a failure to attend to core emotional features (viz., the eyes) of attachment figures. The current study tested whether impaired eye contact is a…

  8. Use of krypton laser stimulation in the treatment of dry eye syndrome

    NASA Astrophysics Data System (ADS)

    Kecik, Tadeusz; Switka-Wieclawska, Iwona; Ciszewska, Joanna; Portacha, Lidia

    1991-08-01

    We''d like to present the use of krypton laser stimulation in the treatment of dry eye syndrom. 10 patients with dry eye syndrom were treated with irradiation of the lacrimal gland. Schirmer test and break up time were performed before and after therapy. After 10 days of treatment we observed higher value of secreted tear amount.

  9. A common stochastic accumulator with effector-dependent noise can explain eye-hand coordination

    PubMed Central

    Gopal, Atul; Viswanathan, Pooja

    2015-01-01

    The computational architecture that enables the flexible coupling between otherwise independent eye and hand effector systems is not understood. By using a drift diffusion framework, in which variability of the reaction time (RT) distribution scales with mean RT, we tested the ability of a common stochastic accumulator to explain eye-hand coordination. Using a combination of behavior, computational modeling and electromyography, we show how a single stochastic accumulator to threshold, followed by noisy effector-dependent delays, explains eye-hand RT distributions and their correlation, while an alternate independent, interactive eye and hand accumulator model does not. Interestingly, the common accumulator model did not explain the RT distributions of the same subjects when they made eye and hand movements in isolation. Taken together, these data suggest that a dedicated circuit underlies coordinated eye-hand planning. PMID:25568161

  10. [Effect of anti-inflammatory therapy on the treatment of dry eye syndrome].

    PubMed

    Mrukwa-Kominek, Ewa; Rogowska-Godela, Anna; Gierek-Ciaciura, Stanisława

    2007-01-01

    Dry eye syndrome is a common chronic disease; agents and strategies for its effective management are still lacking. The syndrome tends to be accompanied by ocular surface inflammation; therefore, the use of anti-inflammatory agents might prove beneficial. The authors present up-to-date guidelines, strategies, and efficacy of dry eye syndrome management, including anti-inflammatory treatment. As no diagnostic tests are now available to assess ocular surface inflammation severity, the right timing to launch an anti-inflammatory agent is difficult to determine. Patients with mild intermittent bouts of symptoms which can be alleviated with ophthalmic lubricants do not typically require anti-inflammatory therapy. The latter should be considered in those who do not respond to lubricating drops, obtain poor results on clinical tests, and show symptoms of ocular surface irritation (eg. conjunctivae redness). Anti-inflammatory treatment of dry eye syndrome may include short-term corticosteroids, cyclosporine A emulsion, oral tetracycline therapy, oral omega-3 fatty acid supplements, and autologous serum eye drops. Anti-inflammatory treatment should be safe and effective; potential benefits should be evaluated for each individual patient. The authors have reviewed the advantages of anti-inflammatory treatment in dry eye syndrome, presented in literature.

  11. Mucoadhesive Microparticles in a Rapidly Dissolving Tablet for Sustained Drug Delivery to the Eye

    PubMed Central

    Choy, Young Bin; Patel, Samirkumar R.; Park, Jung-Hwan; McCarey, Bernard E.; Edelhauser, Henry F.

    2011-01-01

    Purpose. To test the hypothesis that mucoadhesive microparticles formulated in a rapidly dissolving tablet can achieve sustained drug delivery to the eye. Methods. Mucoadhesive microparticles, smaller than 5 μm were fabricated with poly(lactic-co-glycolic acid) and poly(ethylene glycol) as a core material and mucoadhesion promoter, respectively, and encapsulated pilocarpine as a model drug. These microparticles were embedded in a poly(vinyl alcohol) matrix to form a dry tablet designed to reduce rapid clearance of the microparticles on initial application to the eye. Results. This in vitro drug release study exhibited that for all formulations, approximately 90% of pilocarpine was released during the first 10 minutes, and the remaining 10% was released slowly for 3 hours. In vivo mucoadhesion test on the rabbit eye indicated that mucoadhesive microparticles adhered significantly better to the preocular surface than other formulations. To assess the pharmacodynamics, the most prolonged pilocarpine-induced pupil constriction was observed in rabbit eyes in vivo using a tablet with mucoadhesive microparticles; it lasted up to 330 minutes. Conclusions. The authors conclude that mucoadhesive microparticles formulated into a dry dosage form is a promising system for sustained drug delivery to the eye. PMID:21245405

  12. Comparison of two methods for composite score generation in dry eye syndrome.

    PubMed

    See, Craig; Bilonick, Richard A; Feuer, William; Galor, Anat

    2013-09-19

    To compare two methods of composite score generation in dry eye syndrome (DES). Male patients seen in the Miami Veterans Affairs eye clinic with normal eyelid, corneal, and conjunctival anatomy were recruited to participate in the study. Patients filled out the Dry Eye Questionnaire 5 (DEQ5) and underwent measurement of tear film parameters. DES severity scores were generated by independent component analysis (ICA) and latent class analysis (LCA). A total of 247 men were included in the study. Mean age was 69 years (SD 9). Using ICA analysis, osmolarity was found to carry the largest weight, followed by eyelid vascularity and meibomian orifice plugging. Conjunctival injection and tear breakup time (TBUT) carried the lowest weights. Using LCA analysis, TBUT was found to be best at discriminating healthy from diseased eyes, followed closely by Schirmer's test. DEQ5, eyelid vascularity, and conjunctival injection were the poorest at discrimination. The adjusted correlation coefficient between the two generated composite scores was 0.63, indicating that the shared variance was less than 40%. Both ICA and LCA produced composite scores for dry eye severity, with weak to moderate agreement; however, agreement for the relative importance of single diagnostic tests was poor between the two methods.

  13. The HIrisPlex-S system for eye, hair and skin colour prediction from DNA: Introduction and forensic developmental validation.

    PubMed

    Chaitanya, Lakshmi; Breslin, Krystal; Zuñiga, Sofia; Wirken, Laura; Pośpiech, Ewelina; Kukla-Bartoszek, Magdalena; Sijen, Titia; Knijff, Peter de; Liu, Fan; Branicki, Wojciech; Kayser, Manfred; Walsh, Susan

    2018-07-01

    Forensic DNA Phenotyping (FDP), i.e. the prediction of human externally visible traits from DNA, has become a fast growing subfield within forensic genetics due to the intelligence information it can provide from DNA traces. FDP outcomes can help focus police investigations in search of unknown perpetrators, who are generally unidentifiable with standard DNA profiling. Therefore, we previously developed and forensically validated the IrisPlex DNA test system for eye colour prediction and the HIrisPlex system for combined eye and hair colour prediction from DNA traces. Here we introduce and forensically validate the HIrisPlex-S DNA test system (S for skin) for the simultaneous prediction of eye, hair, and skin colour from trace DNA. This FDP system consists of two SNaPshot-based multiplex assays targeting a total of 41 SNPs via a novel multiplex assay for 17 skin colour predictive SNPs and the previous HIrisPlex assay for 24 eye and hair colour predictive SNPs, 19 of which also contribute to skin colour prediction. The HIrisPlex-S system further comprises three statistical prediction models, the previously developed IrisPlex model for eye colour prediction based on 6 SNPs, the previous HIrisPlex model for hair colour prediction based on 22 SNPs, and the recently introduced HIrisPlex-S model for skin colour prediction based on 36 SNPs. In the forensic developmental validation testing, the novel 17-plex assay performed in full agreement with the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, as previously shown for the 24-plex assay. Sensitivity testing of the 17-plex assay revealed complete SNP profiles from as little as 63 pg of input DNA, equalling the previously demonstrated sensitivity threshold of the 24-plex HIrisPlex assay. Testing of simulated forensic casework samples such as blood, semen, saliva stains, of inhibited DNA samples, of low quantity touch (trace) DNA samples, and of artificially degraded DNA samples as well as concordance testing, demonstrated the robustness, efficiency, and forensic suitability of the new 17-plex assay, as previously shown for the 24-plex assay. Finally, we provide an update to the publically available HIrisPlex website https://hirisplex.erasmusmc.nl/, now allowing the estimation of individual probabilities for 3 eye, 4 hair, and 5 skin colour categories from HIrisPlex-S input genotypes. The HIrisPlex-S DNA test represents the first forensically validated tool for skin colour prediction, and reflects the first forensically validated tool for simultaneous eye, hair and skin colour prediction from DNA. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Hyperosmolarity response of ocular standing potential as a clinical test for retinal pigment epithelium activity. Chorioretinal dystrophies.

    PubMed

    Yonemura, D; Kawasaki, K; Madachi-Yamamoto, S

    1984-05-30

    The hyperosmolarity response of the standing potential was recorded in retinitis pigmentosa (20 eyes), central (pericentral) retinitis pigmentosa (4 eyes), pigmented paravenous retinochoroidal atrophy (2 eyes), fundus albipunctatus (8 eyes), and Stargardt's disease (or fundus flavimaculatus) (14 eyes). The light peak/dark trough ratio (the L/D ratio) and the Diamox response were also determined. The hyperosmolarity response was greatly suppressed (less than M-4SD; M and SD indicate respectively the mean and the standard deviation in normal control subjects) in all examined eyes with retinitis pigmentosa (20 eyes) including retinitis pigmentosa sine pigmento (8 eyes), central (pericentral) retinitis pigmentosa (4 eyes), and pigmented paravenous retinochoroidal atrophy (2 eyes). The L/D ratio was larger than 1.26 (M-2.5 SD) in the half of the eyes with the above-described diseases. The hyperosmolarity response was abnormal (less than M-2 SD) in 4 of 8 eyes with fundus albipunctatus. The L/D ratio was normal in all 8 eyes. The hyperosmolarity response was abnormal (less than M-2 SD) in all 14 eyes with Stargardt's disease or fundus flavimaculatus. The L/D ratio was abnormal in 5 of these 14 eyes. The hyperosmolarity response was more frequently abnormal than the L/D ratio in the chorioretinal dystrophies mentioned above, and hence is useful particularly for early diagnosis of these disorders.

  15. Hyperosmolarity response of ocular standing potential as a clinical test for retinal pigment epithelium activity chorioretinal dystrophies.

    PubMed

    Yonemura, D; Kawasaki, K; Madachi-Yamamoto, S

    1984-05-01

    The hyperosmolarity response of the standing potential was recorded in retinitis pigmentosa (20 eyes), central (pericentral) retinitis pigmentosa (4 eyes), pigmented paravenous retinochoroidal atrophy (2 eyes), fundus albipunctatus (8 eyes), and Stargardt's disease (or fundus flavimaculatus) (14 eyes). The light peak/dark trough ratio (the L/D ratio) and the Diamox response were also determined.The hyperosmolarity response was greatly suppressed (less than M-4SD; M and SD indicate respectively the mean and the standard deviation in normal control subjects) in all examined eyes with retinitis pigmentosa (20 eyes) including retinitis pigmentosa sine pigmento (8 eyes), central (pericentral) retinitis pigmentosa (4 eyes), and pigmented paravenous retinochoroidal atrophy (2 eyes). The L/D ratio was larger than 1.26 (M-2.5 SD) in the half of the eyes with the above-described diseases.The hyperosmolarity response was abnormal (less than M-2 SD) in 4 of 8 eyes with fundus albipunctatus. The L/D ratio was normal in all 8 eyes.The hyperosmolarity response was abnormal (less than M-2 SD) in all 14 eyes with Stargardt's disease or fundus flavimaculatus. The L/D ratio was abnormal in 5 of these 14 eyes.The hyperosmolarity response was more frequently abnormal than the L/D ratio in the chorioretinal dystrophies mentioned above, and hence is useful particularly for early diagnosis of these disorders.

  16. Double-pass measurement of human eye aberrations: limitations and practical realization

    NASA Astrophysics Data System (ADS)

    Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.

    2004-11-01

    The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.

  17. LASIK and dry eye.

    PubMed

    Toda, Ikuko

    2007-01-01

    Dry eye is one of the most common complications after laser-assisted in situ keratomileusis (LASIK). The clinical signs of post-LASIK dry eye include positive vital staining of ocular surface, decreased tear film breakup time and Schirmer test, reduced corneal sensitivity, and decreased functional visual acuity. The symptoms and signs last at least 1 month after LASIK. Although the mechanisms for developing post-LASIK dry eye are not completely understood, loss of corneal innervation by flap-making may affect the reflex loops of the corneal-lacrimal gland, corneal-blinking, and blinking-meibomian gland, and blinking-meibomian gland, resulting in decreased aqueous and lipid tear secretion and mucin expression. As LASIK enhancement by flap-lifting induces less dry eye symptoms and signs than first surgery, it is suggested that other factors rather than loss of neurotrophic effect may be involved in the mechanisms of post-LASIK dry eye. The treatments of dry eye include artificial tears, topical cyclosporine, hot compress, punctal plugs, and autologous serum eye drops. For patients with severe preoperative dry eye, a combination of punctal plugs and serum eye drops is required to be used before surgery.

  18. Mandibular deviations in TMD and non-TMD groups related to eye dominance and head posture.

    PubMed

    Pradham, N S; White, G E; Mehta, N; Forgione, A

    2001-01-01

    This study was designed to determine whether eye-dominance affects head posture (rotation) and in turn, whether head posture is associated with mandibular frenum midline deviation, in both TMJ and control subjects. Eye dominance was determined using three tests: Porta, Hole, Point tests. Natural head posture was evaluated using the Arthrodial protractor. Mandibular frenum deviation was recorded as left, right or no deviation. Fifty female subjects were included in the study, 25 TMJ patients attending the Gelb Craniomandibular Pain Center and 25 non-TMJ control subjects. The findings indicate that eye dominance and direction of head rotation are strongly associated in both TMJ and control subjects. Further, in TMJ subjects mandibular deviation occurred in greater frequency than in controls and tends to occur in the contra lateral direction of head rotation.

  19. Eye tracking reveals a crucial role for facial motion in recognition of faces by infants

    PubMed Central

    Xiao, Naiqi G.; Quinn, Paul C.; Liu, Shaoying; Ge, Liezhong; Pascalis, Olivier; Lee, Kang

    2015-01-01

    Current knowledge about face processing in infancy comes largely from studies using static face stimuli, but faces that infants see in the real world are mostly moving ones. To bridge this gap, 3-, 6-, and 9-month-old Asian infants (N = 118) were familiarized with either moving or static Asian female faces and then their face recognition was tested with static face images. Eye tracking methodology was used to record eye movements during familiarization and test phases. The results showed a developmental change in eye movement patterns, but only for the moving faces. In addition, the more infants shifted their fixations across facial regions, the better was their face recognition, but only for the moving faces. The results suggest that facial movement influences the way faces are encoded from early in development. PMID:26010387

  20. Does Assessing Eye Alignment along with Refractive Error or Visual Acuity Increase Sensitivity for Detection of Strabismus in Preschool Vision Screening?

    PubMed Central

    2007-01-01

    Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881

  1. Test of the neurolinguistic programming hypothesis that eye-movements relate to processing imagery.

    PubMed

    Wertheim, E H; Habib, C; Cumming, G

    1986-04-01

    Bandler and Grinder's hypothesis that eye-movements reflect sensory processing was examined. 28 volunteers first memorized and then recalled visual, auditory, and kinesthetic stimuli. Changes in eye-positions during recall were videotaped and categorized by two raters into positions hypothesized by Bandler and Grinder's model to represent visual, auditory, and kinesthetic recall. Planned contrast analyses suggested that visual stimulus items, when recalled, elicited significantly more upward eye-positions and stares than auditory and kinesthetic items. Auditory and kinesthetic items, however, did not elicit more changes in eye-position hypothesized by the model to represent auditory and kinesthetic recall, respectively.

  2. Eye care in the elderly.

    PubMed

    Green, Catherine; Goodfellow, Jonathan; Kubie, Jessica

    2014-07-01

    Eye disease and visual impairment are common in the elderly and are associated with social and functional decline, the need to access community support services, depression, falls, nursing home placement and increased mortality. To provide guidance for general practitioners in the detection and recommended management of the most important eye conditions in the elderly in Australia: refractive error, cataract, diabetic retinopathy, age-related macular degeneration and glaucoma. Timely detection and treatment of eye disease can greatly reduce its morbidity. Elderly patients should be encouraged to undergo eye testing every 2 years. Health professionals, including general practitioners, optometrists and ophthalmologists should work collaboratively to ensure patients have access to appropriate disease detection and treatment.

  3. Exposure of eyes to perfume: a double-blind, placebo-controlled experiment.

    PubMed

    Elberling, J; Duus Johansen, J; Dirksen, A; Mosbech, H

    2006-08-01

    Environmental perfume exposure can elicit bothersome respiratory symptoms. Symptoms are induced at exposure levels which most people find tolerable, and the mechanisms are unclear. The aim of the study was to investigate patients with eye and respiratory symptoms related to environmental perfume, by exposing the eyes to perfume in a double-blind, placebo-controlled study.Twenty-one eczema patients with respiratory symptoms elicited by perfume were compared with 21 healthy volunteers in a sex- and age-matched case-control study. The participants completed a symptom questionnaire, and underwent a double-blind, placebo-controlled exposure to perfume. Of the 42 individuals tested, 10 had more eye symptoms (irritation, itching, and tears) during perfume exposure than during placebo exposures, and eight of these individuals (P = 0.07, Fisher's exact test) belonged to the patient group. A true positive eye reaction to perfume was significantly associated with identification of perfume as an active exposure (P < 0.05). In this study, vapor of perfume elicited irritation in the eyes independently of olfaction, but the relative importance of ocular chemoperception in relation to elicitation of respiratory symptoms from common environmental exposures to perfume remains unclear. We investigated the hypothesis of an association between respiratory symptoms related to perfume and ocular perfume sensitivity by exposing the eyes to perfume in a double blind, placebo-controlled experiment. Vapors of perfume provoked symptoms in the relevant eye in some patients and healthy control persons, but under our exposure conditions, ocular chemesthesis failed to elicit respiratory symptoms.

  4. Do Hyperactive Children Have Manifestations of Hyperactivity in Their Eye Movements?

    ERIC Educational Resources Information Center

    Cohen, Bernard; And Others

    A study involving 18 hyperkinetic children (from 3- to 12-years old) was conducted to test the hypothesis that hyperactive children manifest the same type of hypermotility in their eyes as in the rest of their body. Ss were observed under a series of test conditions (including manual problem solving) which elicit short and long periods of…

  5. Corneal Protection for Burn Patients

    DTIC Science & Technology

    2014-11-01

    multiplex immunoassays utilizing the Luminex bead array were procured. Tested chemokines/cytokines include EGF, FGF-2, Eotaxin, IFN, GRO, MDC, PDGF-BB, IL...17A, IL-1RA, IL- 3, IL-6, IL-8, MP-1a and VEGF. A separate assay was used to test for matrix metalloproteinase 9 (MMP 9) given its known up...regulation in dry eye models and clinical scenarios. The tested cytokines were chosen based on their reported prevalence in dry eye states and the

  6. Preliminary effects of oral uridine on the ocular surface in dry eye patients.

    PubMed

    Chang, Ki Cheol; Oh, Joo Youn; In, Youn Seok; Kim, Mee Kum; Shin, Ki Cheul; Wee, Won Ryang; Lee, Jin Hak; Park, Myung Gyu

    2009-08-01

    We designed a randomized, double blinded, 3-months controlled prospective clinical study to investigate effects of oral uridine on the ocular surface in dry eye patients. Twenty-seven patients who diagnosed as dry eye with lower than 5 mm of wetting in the Schirmer strip, with corneal epithelial erosion and who completely followed-up till 3 months were enrolled. Corneal-conjunctival fluorescein staining, non-anesthetic Schirmer test, impression cytology, and Ocular Surface Disease Index (OSDI) were evaluated in the experimental and placebo groups at the baseline, 1 and 3 months after start of medication in a double blinded manner. Fluorescein stain score of the cornea was markedly decreased in oral uridine group compared to the placebo group at 3 months after medication (P=0.032, Mann-Whitney U test). The Schirmer wetting score for the oral uridine group was significantly increased (P=0.001, Wilcoxon signed rank test) at 3 months and its difference between two groups was statistically significant (P=0.030, Mann-Whitney U test). OSDI scores were significantly decreased at 1 and 3 months in treatment group. Oral uridine is effective in treatment of dry eyes.

  7. Effect of unilateral congenital cataract surgery on ocular axial length growth and corneal flattening.

    PubMed

    Borghol-Kassar, R; Menezo-Rozalén, J L; Harto-Castaño, M A; Desco-Esteban, M C

    2015-03-01

    The aim of this article is to study the effect of unilateral congenital cataract surgery on ocular growth and corneal flattening. This is a cross-sectional study of 59 patients operated on due to a unilateral congenital cataract. The median age of the patients at the time of diagnosis was 17 months (interquartile range, 5-39 months). The median age at cataract the time of surgery was 28 months (interquartile range, 8-52 months), and the mean follow-up between cataract surgery and assessments was 149.7±69.9 months (range, 30-319 months). Axial length and corneal curvature were measured in both operated and non-operated eyes, comparing the results between them. There were no statistically significant differences for axial length growth or corneal flattening between operated and non-operated eyes: axial length (P=.327, Student t test) and corneal curvature (P=.078, Student t test). A sub-analysis was performed using the visual acuity and the age of the patient at the time of surgery. The only statistically significant data (P=.007, Student t test) was a lower axial length in operated eyes compared to non-operated eyes, in the non-deep-amblyopia group. No significant axial length growth modifications were observed between operated and non-operated eyes. Only the non-deep-amblyopia group presented with a lower axial length in the operated eyes compared to non-operated eyes. No significant differences in corneal flattening were found between groups after unilateral congenital cataract surgery. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  8. The leaves of Diospyros kaki exert beneficial effects on a benzalkonium chloride-induced murine dry eye model.

    PubMed

    Kim, Kyung-A; Hyun, Lee Chung; Jung, Sang Hoon; Yang, Sung Jae

    2016-01-01

    In this study, the beneficial effects of the oral administration of ethanol extract of Diospyros kaki (EEDK) were tested on a mouse dry eye model induced by benzalkonium chloride (BAC). A solution of 0.2% BAC was administered topically to mouse eyes for 14 days, twice daily, to induce dry eye. Various concentrations of EEDK were administrated daily by oral gavage for 14 days after BAC treatment. Preservative-free eye drops were instilled in the positive-control group. The tear secretion volume (Schirmer's test), tear break-up time (BUT), and fluorescein score were measured on the ocular surface. BAC-induced corneal damage was tested with hematoxylin-eosin staining. Moreover, apoptotic cell death in the corneal epithelial layer was investigated with terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) staining. The protein expression level of interleukin-1alpha (IL-1α), IL-1β, IL-6, tumor necrosis factor- alpha (TNF-α), and monocyte chemotactic protein-1 (MCP-1) was determined with western blot analysis. Furthermore, squamous metaplasia in the corneal epithelial layer was detected with immunofluorescent staining for cytokeratine-10. The cellular proliferation in the cornea was examined with immunohistochemical staining for Ki-67. EEDK treatment resulted in prolonged BUT, decreased fluorescein score, increased tear volume, and smoother epithelial cells compared with BAC treatment alone in the cornea. Moreover, EEDK treatment inhibited the inflammatory response and corneal epithelial cell death in a BAC-induced murine dry eye model, and changes in squamous cells were inhibited. Proliferative activity in the corneal epithelium cells was improved with EEDK. EEDK could be a potential therapeutic agent in the clinical treatment of dry eye.

  9. The fate of eyes with wet AMD beyond four years of anti-VEGF therapy.

    PubMed

    Garweg, Justus G; Zirpel, Johanna J; Gerhardt, Christin; Pfister, Isabel B

    2018-04-01

    Real-life studies on long-term functional outcome of anti-VEGF treatment for wet age-related macular degeneration (wAMD) are limited. We therefore assessed the 10-year outcomes in our patients. In this retrospective study, all patients with newly diagnosed wAMD that had received minimally three intravitreal injections between 2007 and 2012 and a follow-up of ≥48 months were included. Primary outcome measure was the evolution of best-corrected visual acuity (BCVA) over time. For qualitative, quantitative and longitudinal data, Pearson's chi 2 test, the Mann-Whitney U-test and Wilcoxon's signed-rank test were applied at a significance level of p < 0.05. Of 267 eyes (219 patients) with newly diagnosed wAMD treated during this period, 104 eyes (104 patients) had been followed for at least 48 months and were included. Fifty-nine eyes (57.8%) after 7 years were still under active treatment, 29 eyes (25.0%) had interrupted treatment [mean follow-up 7.5 years (4.0-10.1; SD 1.6)], whereas 16 patients had died. BCVA stabilized at -7.3 to -11.9 letters after 3-10 years of follow-up with a mean of 2.8 injections (median; 3.0, SD 1.0; 1-5) and 5.1 visits per year. In two thirds of eyes, treatment was switched to aflibercept or corticosteroid combinations without bearing on functional outcomes. Thirty-seven percent (37%) of eyes maintained driving vision for up to 10 years. Beyond 3 years of treatment, functional stability was maintained for up to 10 years. Further improvement of long-term outcomes might have required a more intensive treatment in the early phase.

  10. Orientation Discrimination with Macular Changes Associated with Early AMD

    PubMed Central

    Bedell, Harold E.; Tong, Jianliang; Woo, Stanley Y.; House, Jon R.; Nguyen, Tammy

    2010-01-01

    Purpose Age-related macular degeneration (AMD) is a condition that progressively reduces central vision in elderly individuals, resulting in a reduced capacity to perform many daily activities and a diminished quality of life. Recent studies identified clinical treatments that can slow or reverse the progression of exudative (wet) AMD and ongoing research is evaluating earlier interventions. Because early diagnosis is critical for an optimal outcome, the goal of this study is to assess psychophysical orientation discrimination for randomly positioned short line segments as a potential indicator of subtle macular changes in eyes with early AMD. Methods Orientation discrimination was measured in a sample of 74 eyes of patients aged 47 to 82 years old, none of which had intermediate or advanced AMD. Amsler-grid testing was performed as well. A masked examiner graded each eye as level 0, 1, 2, or 3 on a streamlined version of the Age-Related Eye Disease Study (AREDS) scale for AMD, based on the presence and extent of macular drusen or retinal pigment epithelium (RPE) changes. Visual acuity in the 74 eyes ranged from 20/15 to 20/40+1, with no significant differences among the grading levels. Humphrey 10–2 and Nidek MP-1 micro-perimetry were used to assess retinal sensitivity at test locations 1° from the locus of fixation. Results Average orientation-discrimination thresholds increased systematically from 7.4° to 11.3° according to the level of macular changes. In contrast, only 3 of 74 eyes exhibited abnormalities on the Amsler grid and central-field perimetric defects occurred with approximately equal probability at all grading levels. Conclusions In contrast to Amsler grid and central-visual-field testing, psychophysical orientation discrimination has the capability to distinguish between eyes with and without subtle age-related macular changes. PMID:19319009

  11. Adults Scan Own- and Other-Race Faces Differently

    PubMed Central

    Fu, Genyue; Hu, Chao S.; Wang, Qiandong; Quinn, Paul C.; Lee, Kang

    2012-01-01

    It is well established that individuals show an other-race effect (ORE) in face recognition: they recognize own-race faces better than other-race faces. The present study tested the hypothesis that individuals would also scan own- and other-race faces differently. We asked Chinese participants to remember Chinese and Caucasian faces and we tested their memory of the faces over five testing blocks. The participants' eye movements were recorded with the use of an eye tracker. The data were analyzed with an Area of Interest approach using the key AOIs of a face (eyes, nose, and mouth). Also, we used the iMap toolbox to analyze the raw data of participants' fixation on each pixel of the entire face. Results from both types of analyses strongly supported the hypothesis. When viewing target Chinese or Caucasian faces, Chinese participants spent a significantly greater proportion of fixation time on the eyes of other-race Caucasian faces than the eyes of own-race Chinese faces. In contrast, they spent a significantly greater proportion of fixation time on the nose and mouth of Chinese faces than the nose and mouth of Caucasian faces. This pattern of differential fixation, for own- and other-race eyes and nose in particular, was consistent even as participants became increasingly familiar with the target faces of both races. The results could not be explained by the perceptual salience of the Chinese nose or Caucasian eyes because these features were not differentially salient across the races. Our results are discussed in terms of the facial morphological differences between Chinese and Caucasian faces and the enculturation of mutual gaze norms in East Asian cultures. PMID:22675486

  12. Adults scan own- and other-race faces differently.

    PubMed

    Fu, Genyue; Hu, Chao S; Wang, Qiandong; Quinn, Paul C; Lee, Kang

    2012-01-01

    It is well established that individuals show an other-race effect (ORE) in face recognition: they recognize own-race faces better than other-race faces. The present study tested the hypothesis that individuals would also scan own- and other-race faces differently. We asked Chinese participants to remember Chinese and Caucasian faces and we tested their memory of the faces over five testing blocks. The participants' eye movements were recorded with the use of an eye tracker. The data were analyzed with an Area of Interest approach using the key AOIs of a face (eyes, nose, and mouth). Also, we used the iMap toolbox to analyze the raw data of participants' fixation on each pixel of the entire face. Results from both types of analyses strongly supported the hypothesis. When viewing target Chinese or Caucasian faces, Chinese participants spent a significantly greater proportion of fixation time on the eyes of other-race Caucasian faces than the eyes of own-race Chinese faces. In contrast, they spent a significantly greater proportion of fixation time on the nose and mouth of Chinese faces than the nose and mouth of Caucasian faces. This pattern of differential fixation, for own- and other-race eyes and nose in particular, was consistent even as participants became increasingly familiar with the target faces of both races. The results could not be explained by the perceptual salience of the Chinese nose or Caucasian eyes because these features were not differentially salient across the races. Our results are discussed in terms of the facial morphological differences between Chinese and Caucasian faces and the enculturation of mutual gaze norms in East Asian cultures.

  13. Visual laterality responses to different emotive stimuli by red-capped mangabeys, Cercocebus torquatus torquatus.

    PubMed

    de Latude, Marion; Demange, Marianne; Bec, Philippe; Blois-Heulin, Catherine

    2009-01-01

    Hemispheric asymmetry in emotional perception has been put forward by different theories as the right hemisphere theory or the valence theory. But no consensus was found about the role played by both hemispheres. So, in order to test the different theories, we investigated preferential use of one eye in red-capped mangabeys, at the individual as well as at the group level. In this study we investigated the influence of the emotional value of stimuli on the direction and strength of visual preference of 14 red-capped mangabeys. Temporal stability of the bias of use of a given eye was evaluated by comparing our current results to those obtained 2.5 months previously. Two experimental devices, a tube and a box, tested five different stimuli: four food types varying in palatability and a neutral stimulus. The subjects' food preferences were evaluated before testing the laterality. The mangabeys used their left eyes predominantly at the group level for the tube task. The majority of the subjects showed a visual preference at the individual level for the box task, but this bias was not present at the group level. As the palatability of the stimuli increased, the number of lateralized subjects and the number of subjects using preferentially their left eye increased. Similarly, the strength of laterality was related to food preference. Strength of laterality was significantly higher for subjects using their left eye than for subjects using their right eye. Preferential use of a given eye was stable over short periods 2.5 months later. Our data agree with reports on visual laterality for other species. Our results support the valence theory of a hemispheric sharing of control of emotions in relation to their emotional value.

  14. Evaluation of Lacrimation Characteristics in Clinically Normal New Zealand White Rabbits by Using the Schirmer Tear Test I

    PubMed Central

    Whittaker, Alexandra L; Williams, David L

    2015-01-01

    Rabbits are a common animal model in eye research and in safety testing of novel chemical agents. In addition, ocular disease is a routine presentation in clinical practice. However, few studies have quantitatively examined lacrimation kinetics in this species. This study used a noninvasive method of tear measurement (the Schirmer tear test, STT) to quantify values for basal and reflex tearing and to determine the kinetic nature of tear production in 76 New Zealand white rabbits. We obtained a value of 7.58 ± 2.3 mm/min for the standard 1-min STT. Calculated values for mean residual tear volume and reflex tear flow were 1.95 µL and 0.035 µL/s, respectively. In addition, this study provides preliminary evidence for an interaction effect between eyes given that higher STT values were obtained from the second eye tested. PMID:26632789

  15. Efficacy of Several Therapeutic Agents in a Murine Model of Dry Eye Syndrome

    PubMed Central

    Kilic, Servet; Kulualp, Kadri

    2016-01-01

    In the current study, we used 56 female BALB/c mice with induced dry eye syndrome to evaluate the therapeutic effects of formal saline (FS), sodium hyaluronate (SH), diclofenac sodium (DS), olopatadine (OP), retinoic acid (RA), fluoromethanole (FML), cyclosporine A (CsA), and doxycycline hyclate (DH). All subjects were kept in an evaporative ‘dry eye cabinet’ for the assessment of blink rate, tear production, tear break-up time, and impression cytology prior to (baseline) and during weeks 2, 4, and 6 of the study. The right eyes of all subjects were treated topically with 5 µL of the test agent twice daily during weeks 2 through 6. Impression cytology and tear break-up time differed between time points in all groups and differed between groups at weeks 4 and 6. Blink rate differed by time point only in the FS, FML, and DH groups. Tear production according to the phenol red cotton thread test differed by time point for all groups except RA, CsA, and DH and differed between groups only at week 6. Among the compounds tested in the present study, DS and CsA were the most effective therapeutic agents in our mouse model of dry eye syndrome; these agents likely exert their therapeutic effect through their antiinflammatory activity. PMID:27053565

  16. The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye

    NASA Astrophysics Data System (ADS)

    Krumina, Gunta; Ozolinsh, Maris; Ikaunieks, Gatis

    2008-09-01

    In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminant coloured stimuli (white symbols on a yellow background, grey symbols on blue, green or red background). Thus isoluminant tests had colour contrast only but had no luminance contrast. Visual acuity evaluated with the standard method and colour tests were studied for subjects with good visual acuity, if necessary using the best vision correction. The same was performed for subjects with defocused eye and with true amblyopia. Defocus was realized with optical lenses placed in front of the normal eye. The obtained results applying the isoluminant colour charts revealed worsening of the visual acuity comparing with the visual acuity estimated with a standard high contrast method (black symbols on a white background).

  17. An in vitro study to find the incidence of mesiobuccal 2 canal in permanent maxillary first molars using three different methods.

    PubMed

    Vasundhara, V; Lashkari, Krishna Prasada

    2017-01-01

    In-vitro study was done to evaluate the incidence of MB2 canals using three different methods (CBCT, CLINICAL ANALYSIS AND DENTAL LOUPES) and to compare the efficacy of the three methods in identifying the incidence of MB2 canals in maxillary permanent first molars. The study sample consisted of 120 extracted intact permanent maxillary molars. These extracted teeth were subjected to CBCT. Later the teeth were access opened with naked eye to find the incidence of MB2 canal, and then the teeth were visualised under dental loupe to locate MB2 canal if they were missed under naked eye. Results was statistically analysed by Mc Nemar's tests with Bonferroni correction, Chi square test and Cochran's Q test. CBCT showed high incidence (68.3%) of MB2 canal in maxillary first molars and it showed to be a reliable method in detecting MB2 canal. When compared to dental loupe (52.5%) and naked eye (25%), the dental loupe improved the detection of MB2 canal. Within the parameter of this study in detecting the incidence of MB2 canal, using CBCT dental loupes and naked eye, detection of MB2 canal was significantly higher with CBCT followed by dental loupe and least with naked eye.

  18. Fundus autofluorescence, optical coherence tomography, and electroretinogram findings in choroidal sclerosis.

    PubMed

    Hwang, John C; Kim, David Y; Chou, Chai Lin; Tsang, Stephen H

    2010-01-01

    The purpose of this study was to describe fundus autofluorescence (FAF), optical coherence tomography, and electroretinogram findings in choroidal sclerosis. This is a retrospective case series. Eight eyes of four patients with choroidal sclerosis were evaluated with FAF, optical coherence tomography, and electroretinogram testing. In all eight eyes, FAF imaging showed hypofluorescent placoid lesions corresponding to areas of chorioretinal atrophy seen on stereo biomicroscopy. Prominent hyperfluorescent linear markings underlying regions of atrophic disease were observed in all eyes, likely representative of normal choroidal vessel autofluorescence. In two eyes, FAF showed punctate hypofluorescent lesions in the fovea that were not visualized on biomicroscopy. In one eye, FAF identified a central island of preserved retinal pigment epithelium that was not realized on ophthalmoscopic examination. Optical coherence imaging was significant for loss of choroidal fine tubular structures, retinal pigment epithelium, and outer nuclear layer in regions of chorioretinal atrophy. Full-field electroretinogram testing showed generalized rod-cone dysfunction in all patients with a lower B- to A-wave ratio in two patients. Fundus autofluorescence and optical coherence tomography are nonin-vasive diagnostic adjuncts that can aid in the diagnosis of choroidal sclerosis. Fundus autofluorescence may be a more sensitive marker of disease extent and progression than clinical examination alone. Electroretinogram testing can result in an electronegative maximal response.

  19. Impairments in Dark Adaptation Are Associated with Age-Related Macular Degeneration Severity and Reticular Pseudodrusen.

    PubMed

    Flamendorf, Jason; Agrón, Elvira; Wong, Wai T; Thompson, Darby; Wiley, Henry E; Doss, E Lauren; Al-Holou, Shaza; Ferris, Frederick L; Chew, Emily Y; Cukras, Catherine

    2015-10-01

    We investigate whether ocular and person-based characteristics were associated with dark adaptation (DA). Cross-sectional, single-center, observational study. One hundred sixteen participants older than 50 years of age with a range of age-related macular degeneration (AMD) severity. Participants underwent best-corrected visual acuity (BCVA) testing, ophthalmoscopic examination, and multimodal imaging. Presence of reticular pseudodrusen (RPD) was assessed by masked grading of fundus images and was confirmed with optical coherence tomography. Eyes also were graded for AMD features (drusen, pigmentary changes, late AMD) to generate person-based AMD severity groups. One eye was designated the study eye for DA testing. Nonparametric statistical testing was performed on all comparisons. The primary outcome of this study was the rod intercept time (RIT), which is defined as the time for a participant's visual sensitivity to recover to a stimulus intensity of 5×10(-3) cd/m(2) (a decrease of 3 log units), or until a maximum test duration of 40 minutes was reached. A total of 116 study eyes from 116 participants (mean age, 75.4±9.4 years; 58% female) were analyzed. Increased RIT was associated significantly with increasing AMD severity, increasing age (r = 0.34; P = 0.0002), decreasing BCVA (r = -0.54; P < 0.0001), pseudophakia (P = 0.03), and decreasing subfoveal choroidal thickness (r = -0.27; P = 0.003). Study eyes with RPD (15/116 [13%]) had a significantly greater mean RIT compared with eyes without RPD in any AMD severity group (P < 0.02 for all comparisons), with 80% reaching the DA test ceiling. Impairments in DA increased with age, worse visual acuity, presence of RPD, AMD severity, and decreased subfoveal choroidal thickness. Analysis of covariance found the multivariate model that best fit the data included age, AMD group, and presence of RPD (R(2) = 0.56), with the presence of RPD conferring the largest parameter estimate. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Eye Examination Testability in Children with Autism and in Typical Peers

    PubMed Central

    Coulter, Rachel Anastasia; Bade, Annette; Tea, Yin; Fecho, Gregory; Amster, Deborah; Jenewein, Erin; Rodena, Jacqueline; Lyons, Kara Kelley; Mitchell, G. Lynn; Quint, Nicole; Dunbar, Sandra; Ricamato, Michele; Trocchio, Jennie; Kabat, Bonnie; Garcia, Chantel; Radik, Irina

    2015-01-01

    ABSTRACT Purpose To compare testability of vision and eye tests in an examination protocol of 9- to 17-year-old patients with autism spectrum disorder (ASD) to typically developing (TD) peers. Methods In a prospective pilot study, 61 children and adolescents (34 with ASD and 27 who were TD) aged 9 to 17 years completed an eye examination protocol including tests of visual acuity, refraction, convergence (eye teaming), stereoacuity (depth perception), ocular motility, and ocular health. Patients who required new refractive correction were retested after wearing their updated spectacle prescription for 1 month. The specialized protocol incorporated visual, sensory, and communication supports. A psychologist determined group status/eligibility using DSM-IV-TR (Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision) criteria by review of previous evaluations and parent responses on the Social Communication Questionnaire. Before the examination, parents provided information regarding patients’ sex, race, ethnicity, and, for ASD patients, verbal communication level (nonverbal, uses short words, verbal). Parents indicated whether the patient wore a refractive correction, whether the patient had ever had an eye examination, and the age at the last examination. Chi-square tests compared testability results for TD and ASD groups. Results Typically developing and ASD groups did not differ by age (p = 0.54), sex (p = 0.53), or ethnicity (p = 0.22). Testability was high on most tests (TD, 100%; ASD, 88 to 100%), except for intraocular pressure (IOP), which was reduced for both the ASD (71%) and the TD (89%) patients. Among ASD patients, IOP testability varied greatly with verbal communication level (p < 0.001). Although IOP measurements were completed on all verbal patients, only 37.5% of nonverbal and 44.4% of ASD patients who used short words were successful. Conclusions Patients with ASD can complete most vision and eye tests within an examination protocol. Testability of IOPs is reduced, particularly for nonverbal patients and patients who use short words to communicate. PMID:25415280

  1. Effect of stimulus configuration on crowding in strabismic amblyopia.

    PubMed

    Norgett, Yvonne; Siderov, John

    2017-11-01

    Foveal vision in strabismic amblyopia can show increased levels of crowding, akin to typical peripheral vision. Target-flanker similarity and visual-acuity test configuration may cause the magnitude of crowding to vary in strabismic amblyopia. We used custom-designed visual acuity tests to investigate crowding in observers with strabismic amblyopia. LogMAR was measured monocularly in both eyes of 11 adults with strabismic or mixed strabismic/anisometropic amblyopia using custom-designed letter tests. The tests used single-letter and linear formats with either bar or letter flankers to introduce crowding. Tests were presented monocularly on a high-resolution display at a test distance of 4 m, using standardized instructions. For each condition, five letters of each size were shown; testing continued until three letters of a given size were named incorrectly. Uncrowded logMAR was subtracted from logMAR in each of the crowded tests to highlight the crowding effect. Repeated-measures ANOVA showed that letter flankers and linear presentation individually resulted in poorer performance in the amblyopic eyes (respectively, mean normalized logMAR = 0.29, SE = 0.07, mean normalized logMAR = 0.27, SE = 0.07; p < 0.05) and together had an additive effect (mean = 0.42, SE = 0.09, p < 0.001). There was no difference across the tests in the fellow eyes (p > 0.05). Both linear presentation and letter rather than bar flankers increase crowding in the amblyopic eyes of people with strabismic amblyopia. These results suggest the influence of more than one mechanism contributing to crowding in linear visual-acuity charts with letter flankers.

  2. Neurophthalmological conditions mimicking glaucomatous optic neuropathy: analysis of the most common causes of misdiagnosis.

    PubMed

    Dias, Diego Torres; Ushida, Michele; Battistella, Roberto; Dorairaj, Syril; Prata, Tiago Santos

    2017-01-10

    To analyze the most common neurophthalmological conditions that may mimic glaucomatous optic neuropathy and to determine which most often lead to misdiagnosis when evaluated by a glaucoma specialist. We reviewed the charts of consecutive patients with optic neuropathies caused by neurophthalmological conditions screened in a single Eye Clinic within a period of 24 months. Within these enrolled patients, we selected the eyes whose fundoscopic appearance could resemble glaucoma based in pre-defined criteria (vertical cup-to-disc ratio ≥0.6, asymmetry of the cup-to-disc ratio ≥0.2 between eyes, presence of localized retinal nerve fiber layer and/or neuroretinal rim defects, and disc haemorrhages). Then, color fundus photographs and Humphrey Visual Field tests (HVF) of these eyes were mixed with tests from 21 consecutive glaucomatous patients (42 eyes with normal tension glaucoma). These images were mixed randomly and a masked glaucoma specialist was asked to distinguish if each set of exams was from a patient with glaucoma or with a neurophthalmologic condition. Among the 101 eyes (68 patients) enrolled with neurophthalmological diseases, 16 (15.8%) were classified as conditions that could mimic glaucoma. The most common diagnoses were ischemic optic neuropathy (25%), compressive optic neuropathy (18.7%) and hereditary optic neuropathy (18.7%). Based on the analysis of fundus photographs and HVF tests, 25% of these were misdiagnosed as glaucoma (two ischemic optic neuropathies and two congenital optic disc anomalies). Conversely, 11.9% of the glaucomatous neuropathies were misdiagnosed as neurophthalmological disorders. Overall, the glaucoma specialist correctly diagnosed 84.5% of the eyes. Some neurophthalmological disorders can mimic glaucoma. In our study, isquemic and compressive optic neuropathies were the ones that most often did so. Almost one quarter of the eyes were misdiagnosed when evaluated by a glaucoma specialist, which can lead to inadequate management and influence the prognosis of these patients.

  3. Meibomian Gland Dysfunction Determines the Severity of the Dry Eye Conditions in Visual Display Terminal Workers

    PubMed Central

    Dong, Nuo; Yang, Fan; Lin, Zhirong; Shang, Xumin; Li, Cheng

    2014-01-01

    Objective To explore meibomian gland dysfunction (MGD) may determine the severity of dry eye conditions in visual display terminal (VDT) workers. Methodology Prospective, case-control study carried out in China.106 eyes of 53 patients (VDT work time >4 hour per day) were recruited as the Long time VDT group; 80 eyes of 40 control subjects (VDT work time ≤4 hour per day) served as the Short time VDT group. A questionnaire of Ocular Surface Disease Index (OSDI) and multiple tests were performed. Three dry eye tests: tear film breakup time (BUT), corneal fluorescein staining, Schirmer I test; and three MGD parameters: lid margin abnormality score, meibum expression assessment (meibum score), and meibomian gland dropout degree (meiboscore) using Keratograph 5 M. Principal Findings OSDI and corneal fluorescein score were significantly higher while BUT was dramatically shorter in the long time VDT group than the short time VDT group. However, the average of Schirmer tear volumes was in normal ranges in both groups. Interestingly, the three MGD parameters were significantly higher in the long time VDT group than the short time one (P<0.0001). When 52 eyes with Schirmer <10 mm and 54 eyes with Schirmer ≥10 mm were separated from the long time VDT workers, no significant differences were found between the two subgroups in OSDI, fluorescein staining and BUT, as well as the three MGD parameters. All three MGD parameters were positively correlated with VDT working time (P<0.0001) and fluorescein scores (P<0.0001), inversely correlated with BUT (P<0.05), but not correlated with Schirmer tear volumes in the VDT workers. Conclusions Our findings suggest that a malfunction of meibomian glands is associated with dry eye patients in long term VDT workers with higher OSDI scores whereas some of those patients presenting a normal tear volume. PMID:25144638

  4. Parkinson’s disease patients show impaired corrective grasp control and eye-hand coupling when reaching to grasp virtual objects

    PubMed Central

    Lukos, Jamie R.; Snider, Joseph; Hernandez, Manuel E.; Tunik, Eugene; Hillyard, Steven; Poizner, Howard

    2013-01-01

    The effect of Parkinson’s disease on hand-eye coordination and corrective response control during reach-to-grasp tasks remains unclear. Moderately impaired Parkinson’s disease patients (PD, n=9) and age-matched controls (n=12) reached to and grasped a virtual rectangular object, with haptic feedback provided to the thumb and index fingertip by two 3-degree of freedom manipulanda. The object rotated unexpectedly on a minority of trials, requiring subjects to adjust their grasp aperture. On half the trials, visual feedback of finger positions disappeared during the initial phase of the reach, when feedforward mechanisms are known to guide movement. PD patients were tested without (OFF) and with (ON) medication to investigate the effects of dopamine depletion and repletion on eye-hand coordination online corrective response control. We quantified eye-hand coordination by monitoring hand kinematics and eye position during the reach. We hypothesized that if the basal ganglia are important for eye-hand coordination and online corrections to object perturbations, then PD patients tested OFF medication would show reduced eye-hand spans and impoverished arm-hand coordination responses to the perturbation, which would be further exasperated when visual feedback of the hand was removed. Strikingly, PD patients tracked their hands with their gaze, and their movements became destabilized when having to make online corrective responses to object perturbations exhibiting pauses and changes in movement direction. These impairments largely remained even when tested in the ON state, despite significant improvement on the Unified Parkinson’s Disease Rating Scale. Our findings suggest that basal ganglia-cortical loops are essential for mediating eye-hand coordination and adaptive online responses for reach-to-grasp movements, and that restoration of tonic levels of dopamine may not be adequate to remediate this coordinative nature of basal ganglia modulated function. PMID:24056196

  5. Macular pigment optical density measurements: evaluation of a device using heterochromatic flicker photometry

    PubMed Central

    de Kinkelder, R; van der Veen, R L P; Verbaak, F D; Faber, D J; van Leeuwen, T G; Berendschot, T T J M

    2011-01-01

    Purpose Accurate assessment of the amount of macular pigment (MPOD) is necessary to investigate the role of carotenoids and their assumed protective functions. High repeatability and reliability are important to monitor patients in studies investigating the influence of diet and supplements on MPOD. We evaluated the Macuscope (Macuvision Europe Ltd., Lapworth, Solihull, UK), a recently introduced device for measuring MPOD using the technique of heterochromatic flicker photometry (HFP). We determined agreement with another HFP device (QuantifEye; MPS 9000 series: Tinsley Precision Instruments Ltd., Croydon, Essex, UK) and a fundus reflectance method. Methods The right eyes of 23 healthy subjects (mean age 33.9±15.1 years) were measured. We determined agreement with QuantifEye and correlation with a fundus reflectance method. Repeatability of QuantifEye was assessed in 20 other healthy subjects (mean age 32.1±7.3 years). Repeatability was also compared with measurements by a fundus reflectance method in 10 subjects. Results We found low agreement between test and retest measurements with Macuscope. The average difference and the limits of agreement were −0.041±0.32. We found high agreement between test and retest measurements of QuantifEye (−0.02±0.18) and the fundus reflectance method (−0.04±0.18). MPOD data obtained by Macuscope and QuantifEye showed poor agreement: −0.017±0.44. For Macuscope and the fundus reflectance method, the correlation coefficient was r=0.05 (P=0.83). A significant correlation of r=0.87 (P<0.001) was found between QuantifEye and the fundus reflectance method. Conclusions Because repeatability of Macuscope measurements was low (ie, wide limits of agreement) and MPOD values correlated poorly with the fundus reflectance method, and agreed poorly with QuantifEye, the tested Macuscope protocol seems less suitable for studying MPOD. PMID:21057522

  6. Tear osmolarity measurements in dry eye related to primary Sjögren's syndrome.

    PubMed

    Utine, Canan Asli; Bıçakçıgil, Müge; Yavuz, Sule; Çiftçi, Ferda

    2011-08-01

    To evaluate the tear osmolarity in patients with dry eye syndrome related to primary Sjögren's Syndrome (SS). Twenty eyes of 10 patients with dry eye and primary SS (Group 1) and 20 eyes of 20 subjects who do not have dry eye syndrome (Group 2) were included in this cross-sectional study. In all eyes, ophthalmic examination was performed in the same order: International Ocular Surface Disease Index survey, visual acuity assessment, conjunctival hyperemia scoring, tear osmolarity measurement with TearLab(™) Osmolarity System, tear film break-up time assessment, corneal fluorescein staining scoring, ocular surface Lissamine Green staining scoring, anesthetized Schirmer test. Dry eye severity was graded according to Dry Eye Workshop (DEWS) classification system. Four eyes with grade 1, four eyes with grade 2, seven eyes with grade 3, and five eyes with grade 4 dryness, according to DEWS system, were included. The mean tear osmolarity value was 301.9 ± 11.40 mOsm/L (range: 290-328) in Group 1, and 294.85 ± 8.33 mOsm/L (range: 283-311) in Group 2 (p = 0.03). In Group 1, tear osmolarity values were positively correlated with OSDI scores (r(18) = 0.55, r(2) = 0.31, p = 0.01), DEWS classification grades (r(18) = 0.73, r(2) = 0.54, p < 0.01), temporal and total corneal staining scores (r(18) = 0.67, r(2) = 0.44, p < 0.01, and r(18) = 0.51, r(2) = 0.26, p = 0.02, respectively), temporal conjunctival staining scores (r(18) = 58, r(2) = 0.34, p < 0.01); and negatively correlated with anesthetized Schirmer test results (r(18) = -0.62, r(2) = 0.38, p < 0.01) and TFBUT (r(18) = -0.50, r(2) = 0.25, p = 0.02). Tear osmolarity values were found to be greater in patients with dry eye syndrome related to primary SS compared to control subjects, and positively correlated with the severity of dry eye.

  7. The opportunistic screening of refractive errors in school-going children by pediatrician using enhanced Brückner test.

    PubMed

    Jain, Piyush; Kothari, Mihir T; Gode, Vaibhav

    2016-10-01

    The aim of this study was to compare the results of enhanced Brückner test (EBT) performed by a pediatrician and an experienced pediatric ophthalmologist. In this prospective double-masked cohort study, a pediatrician and a pediatric ophthalmologist performed the EBT in a classroom of a school in semi-dark lighting condition using a direct ophthalmoscope. The results of the test were compared using 2 × 2 Bayesian table and kappa statistics. The findings of the pediatric ophthalmologists were considered gold standard. Two hundred and thirty-six eyes of 118 subjects, mean age 6.8 ± 0.5 years (range, 5.4-7.8 years), were examined. The time taken to complete this test was <10 s per subject. The ophthalmologist identified 59 eyes as ametropic (12 hyperopic and 47 myopic eyes) and 177 as emmetropic compared to 61 eyes as ametropic and 175 emmetropic by pediatrician. The prevalence of the test positive was 25.9%. The sensitivity of the pediatrician was 90.2%, specificity was 97.7%, predictive value of the positive test was 93.2%, and predictive value of the negative test was 96.6%. The clinical agreement (kappa) between the pediatric ophthalmologist and the pediatrician was 0.9. The results of the EBT performed by pediatrician were comparable to that of an experienced pediatric ophthalmologist. Opportunistic screening of refractive errors using EBT by a pediatrician can be an important approach in the detection of ametropia in children.

  8. Using goggles to increase periocular humidity and reduce dry eye symptoms.

    PubMed

    Korb, Donald R; Blackie, Caroline A

    2013-07-01

    To investigate the use of goggles to increase periocular humidity and reduce dry eye symptoms. Noncontact lens wearing patients, previously diagnosed with and symptomatic for dry eye, were recruited. All patients, test (n = 100) and control (n = 25) patients, were required to fill out a simple questionnaire to assess their ocular comfort at three time points during the study: immediately before wearing goggles, after 20 minutes of continuous goggle wear, and 15 minutes after the goggles were removed. The test group consisted of 100 patients who wore swim goggles. The randomly selected control group consisted of 25 patients who wore goggles with the central lens cut out. Ninety-nine percent of the patients in the test group reported a decrease in their symptoms after the goggles had been worn for 20 minutes. After the goggles had been removed for 15 minutes, the symptoms returned in 88% of the test patients. In the control group, only 24% experienced an improvement in symptoms during goggle wear; 76% experienced no improvement. Increasing the periocular humidity has a significant positive impact on ocular comfort in patients with dry eye. This effect is transient. However, the significance of the improvement is such that the use of goggles should be revisited to help patients suffering from chronic discomfort and other dry eye sequelae. Furthermore, the response of an individual patient to short-term goggle wear may help streamline treatment options for both physicians and patients.

  9. A hybrid method in combining treatment effects from matched and unmatched studies.

    PubMed

    Byun, Jinyoung; Lai, Dejian; Luo, Sheng; Risser, Jan; Tung, Betty; Hardy, Robert J

    2013-12-10

    The most common data structures in the biomedical studies have been matched or unmatched designs. Data structures resulting from a hybrid of the two may create challenges for statistical inferences. The question may arise whether to use parametric or nonparametric methods on the hybrid data structure. The Early Treatment for Retinopathy of Prematurity study was a multicenter clinical trial sponsored by the National Eye Institute. The design produced data requiring a statistical method of a hybrid nature. An infant in this multicenter randomized clinical trial had high-risk prethreshold retinopathy of prematurity that was eligible for treatment in one or both eyes at entry into the trial. During follow-up, recognition visual acuity was accessed for both eyes. Data from both eyes (matched) and from only one eye (unmatched) were eligible to be used in the trial. The new hybrid nonparametric method is a meta-analysis based on combining the Hodges-Lehmann estimates of treatment effects from the Wilcoxon signed rank and rank sum tests. To compare the new method, we used the classic meta-analysis with the t-test method to combine estimates of treatment effects from the paired and two sample t-tests. We used simulations to calculate the empirical size and power of the test statistics, as well as the bias, mean square and confidence interval width of the corresponding estimators. The proposed method provides an effective tool to evaluate data from clinical trials and similar comparative studies. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Ophthalmologist in patients' eyes.

    PubMed

    Derk, Biljana Andrijević; Dapić, Natasa Kovac; Milinković, Branko; Loncar, Valentina Lacmanović; Mijić, Vesna

    2005-01-01

    It seems that patient's knowledge about ophthalmologist's work is very insufficient, especially about what type of examination should be undertaken for refraction condition during the "simple" eye check-up and which serious systemic diseases could be discovered thorough eye examinations. The aim of the study was to determine patients' knowledge about ophthalmologist examinations during the check-up for refraction condition, knowledge about differences between ophthalmologists and opticians, main sources of patients' ophthalmologic cognition and the main reasons for coming to special locations. Patients (311) were examined by applying the questionnaire, immediately before the eye check-up at three various refraction units. Statistical analysis used Chi-square test and test of significance between proportions, except for patients' age where Student t-test was used. Differences were statistically significant at p = 0.05. The findings show that the patients' knowledge about eye examination during the check-ups for refraction abnormalities was not satisfactory. Twenty-two percent (22%) of examined patients did not know the differences between ophthalmologists and opticians and 16% believed that after computer testing of refraction further ophthalmologic examinations were not necessary. The main sources of medical cognition were the mass media while twenty percent (20%) of the participating patients named doctor's lectures as the source of their cognition. This study revealed that a lot of work needs to be done to improve patients' education and indirectly for better screening of very serious systemic diseases and blind threatening diseases which could be discovered during the first visit for spectacle prescription.

  11. Assessment of the vision-specific quality of life using clustered visual field in glaucoma patients.

    PubMed

    Sawada, Hideko; Yoshino, Takaiko; Fukuchi, Takeo; Abe, Haruki

    2014-02-01

    To investigate the significance of vision-specific quality of life (QOL) in glaucoma patients based on the location of visual field defects. We examined 336 eyes of 168 patients. The 25-item National Eye Institute Visual Function Questionnaire was used to evaluate patients' QOL. Visual field testing was performed using the Humphrey Field Analyzer; the visual field was divided into 10 clusters. We defined the eye with better mean deviation as the better eye and the fellow eye as the worse eye. A single linear regression analysis was applied to assess the significance of the relationship between QOL and the clustered visual field. The strongest correlation was observed in the lower paracentral visual field in the better eye. The lower peripheral visual field in the better eye also showed a good correlation. Correlation coefficients in the better eye were generally higher than those in the worse eye. For driving, the upper temporal visual field in the better eye was the most strongly correlated (r=0.509). For role limitation and peripheral vision, the lower peripheral visual field in the better eye had the highest correlation coefficients at 0.459 and 0.425, respectively. Overall, clusters in the lower hemifield in the better eye were more strongly correlated with QOL than those in the worse eye. In particular, the lower paracentral visual field in the better eye was correlated most strongly of all. Driving, however, strongly correlated with the upper hemifield in the better eye.

  12. Diabetes and eye disease

    MedlinePlus

    ... Photocoagulation - retina; Diabetic retinopathy Patient Instructions Diabetes - eye care Diabetes - tests and checkups Type 2 diabetes - what to ... foot care. Sec. 10. In Standards of Medical Care in Diabetes-2017. Diabetes Care 2017;40(Suppl. 1);S88- ...

  13. Intuitive physics and intuitive psychology ("theory of mind") in offspring of mothers with psychoses.

    PubMed

    Maróthi, Rebeka; Kéri, Szabolcs

    2014-01-01

    Offspring of individuals with psychoses sometimes display an abnormal development of cognition, language, motor performance, social adaptation, and emotional functions. The aim of this study was to investigate the ability of children of mothers with schizophrenia (n = 28) and bipolar disorder (n = 23) to understand mental states of others using the Eyes Test (folk psychology or "theory of mind") and physical causal interactions of inanimate objects (folk physics). Compared with healthy controls (n = 29), the children of mothers with schizophrenia displayed significantly impaired performances on the Eyes Test but not on the folk physics test when corrected for IQ. The children of mothers with bipolar disorder did not differ from the controls. The folk physics test showed a significant covariance with IQ, whereas the Eyes Test did not exhibit such covariance. These results suggest that the attribution of mental states, but not the interpretation of causal interaction of objects, is impaired in offspring of individuals with schizophrenia, which may contribute to social dysfunctions.

  14. Repeatability of Central Corneal Thickness Measurement Using Rotating Scheimpflug Camera in Dry and Normal Eyes.

    PubMed

    Lee, Jong-Hyuck; Kim, Jae Hyuck; Kim, Sun Woong

    2017-02-27

    To compare the repeatability of central corneal thickness (CCT) measurement using the Pentacam between dry eyes and healthy eyes, as well as to investigate the effect of artificial tears on CCT measurement. The corneal thicknesses of 34 patients with dry eye and 28 healthy subjects were measured using the Pentacam. One eye from each subject was assigned randomly to a repeatability test, wherein a single operator performed three successive CCT measurements time points-before and 5 min after instillation of one artificial teardrop. The repeatability of measurements was assessed using the coefficient of repeatability and the intraclass correlation coefficient. The coefficient of repeatability values of the CCT measurements in dry and healthy eyes were 24.36 and 10.69 μm before instillation, and 16.85 and 9.72 μm after instillation, respectively. The intraclass correlation coefficient was higher in healthy eyes than that of in dry eyes (0.987 vs. 0.891), and it had improved significantly in dry eyes (0.948) after instillation of one artificial teardrop. The CCT measurement fluctuated in dry eyes (repeated-measures analysis of variance, P<0.001), whereas no significant changes were detected in healthy eyes, either before or after artificial tear instillation. Central corneal thickness measurement is less repeatable in dry eyes than in healthy eyes. Artificial tears improve the repeatability of CCT measurements obtained using the Pentacam in dry eyes.

  15. Evaluating a tablet application and differential reinforcement to increase eye contact in children with autism.

    PubMed

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-03-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a playroom. The tablet application was not effective; however, differential reinforcement was effective for all participants. © 2015 Society for the Experimental Analysis of Behavior.

  16. When the Wheels Touch Earth and the Flight is Through, Pilots Find One Eye is Better Than Two?

    NASA Technical Reports Server (NTRS)

    Valimont, Brian; Wise, John A.; Nichols, Troy; Best, Carl; Suddreth, John; Cupero, Frank

    2009-01-01

    This study investigated the impact of near to eye displays on both operational and visual performance by employing a human-in-the-loop simulation of straight-in ILS approaches while using a near to eye (NTE) display. The approaches were flown in simulated visual and instrument conditions while using either a biocular NTE or a monocular NTE display on either the dominant or non dominant eye. The pilot s flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested.

  17. An Eye for Words: Gauging the Role of Attention in Incidental L2 Vocabulary Acquisition by Means of Eye-Tracking

    ERIC Educational Resources Information Center

    Godfroid, Aline; Boers, Frank; Housen, Alex

    2013-01-01

    This eye-tracking study tests the hypothesis that more attention leads to more learning, following claims that attention to new language elements in the input results in their initial representation in long-term memory (i.e., intake; Robinson, 2003; Schmidt, 1990, 2001). Twenty-eight advanced learners of English read English texts that contained…

  18. Do Unilateral Herpetic Stromal Keratitis and Neurotrophic Ulcers Cause Bilateral Dry Eye?

    PubMed

    Jabbarvand, Mahmoud; Hashemian, Hesam; Khodaparast, Mehdi; Rafatnejad, Amin; Beheshtnejad, Amirhooshang; Salami, Amir

    2015-07-01

    To evaluate and compare the ocular surface condition in herpetic interstitial stromal keratitis and neurotrophic ulcer groups and their normal fellow eyes. In this observational, cross-sectional case-control study, 85 consecutive patients were included, including 56 cases of treated herpetic interstitial keratitis and 29 patients with neurotrophic ulcers. Fifty-six age- and sex-matched participants were also recruited from a normal population as the control group. We evaluated and scored the subjective and objective measures of dry eye for both eyes of all patients. Then, we compared the score of the groups with one another and also with the control group. The main outcome measures were the discomfort level, visual symptoms of dry eye, conjunctival injection, conjunctival staining, corneal staining, corneal tear signs of dry eye, meibomian gland dysfunction, tear break-up time, Schirmer test score with anesthesia, and tear osmolarity. The normal fellow eye of the herpetic keratitis group had significantly higher discomfort levels (1.4 ± 0.9 vs. 1.3 ± 0.5, P = 0.003), visual symptoms (1.7 ± 0.8 vs. 1.3 ± 0.7, P = 0.002), tear break-up time (8.3 ± 3.2 vs. 12.1 ± 3.3 seconds, P = 0.003), Schirmer test scores (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.04), and tear osmolarity (9.2 ± 3.9 vs. 12.9 ± 3 mm, P = 0.003) in comparison with normal controls. The normal fellow eyes of the neurotrophic ulcer group had significantly worse values for discomfort level (1.9 ± 0.9 vs. 1.3 ± 0.5, P < 0.001), tear break-up time (7.9 ± 4 vs. 12.1 ± 3.3, P = 0.004), Schirmer test score (8.1 ± 3.9 vs. 12.9 ± 3, P = 0.005), and tear osmolarity (295 ± 9.2 vs. 292.7 ± 5.9, P = 0.02) compared with normal controls. Both eyes of patients with neurotrophic ulcer and interstitial herpetic keratitis have a significantly poorer ocular surface condition compared with that of normal controls.

  19. Predictors of Discordance between Symptoms and Signs in Dry Eye Disease.

    PubMed

    Vehof, Jelle; Sillevis Smitt-Kamminga, Nicole; Nibourg, Simone A; Hammond, Christopher J

    2017-03-01

    To investigate predictors of discordance between symptoms and signs in dry eye disease (DED). Cross-sectional association study. A total of 648 patients with dry eye from the Groningen LOngitudinal Sicca StudY (GLOSSY), a tertiary dry eye clinic patient cohort from the Netherlands. Patient symptoms were assessed using the Ocular Surface Disease Index (OSDI) questionnaire. Dry eye signs were assessed by tear osmolarity, Schirmer test, tear breakup time, corneal and conjunctival staining, and meibomian gland dysfunction, all in both eyes, and a composite dry eye signs severity score was calculated from these 6 tests for each patient. Linear regression analysis was used to test the association of discordance between symptoms and signs with a wide range of independent variables (demographic and environmental variables, systemic diseases, ocular traits, and medications). Predictors of discordance between symptoms and signs in DED, defined by the difference between the rank score of the OSDI and the rank score of the dry eye signs severity score. Of the 648 subjects in this cohort, 536 (82.7%) were female and the mean age was 55.8 years (standard deviation, 15.6 years). Significant predictors of greater symptoms than signs were the presence of a chronic pain syndrome, atopic diseases, a known allergy, the use of antihistamines (all P < 0.001), depression (P = 0.003), osteoarthritis (P = 0.008), and the use of antidepressants (P = 0.02). Predictors of lesser symptoms than signs were increased age (P < 0.001) and the presence of Sjögren's disease (P < 0.001) (primary Sjögren's disease, P < 0.001) more than secondary Sjögren's disease (P = 0.08), and graft-versus-host disease (P = 0.04). Furthermore, greater symptoms compared with signs were highly associated with lower self-perceived health (P < 0.001). This large clinical study has shown that discordance between symptoms and signs in DED is an indicator of self-perceived health. The study found important predictors of greater symptoms to signs but also predictors of lesser symptoms to signs. Awareness of these predictors is helpful in assessing patients with dry eye in clinical practice. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.

  20. [Clinical study of the effectiveness of a dexpanthenol containing artificial tears solution (Siccaprotect) in treatment of dry eyes].

    PubMed

    Göbbels, M; Gross, D

    1996-01-01

    In this controlled, randomized, double-masked study the effect of dexpanthenol-containing artificial tears (Siccaprotect) on patients with dry eyes was examined. 50 patients applied either dexpanthenol-containing artificial tears (Siccaprotect) or the identical, but free of dexpanthenol, eye drops five times daily into the conjunctival sac. No other ophthalmics were administered. The corneal epithelial permeability was measured by fluorophotometry and Schirmer-Test, Rose Bengal staining, tear film break-up time and the patients' subjective complaints were determined before and after 6 weeks of treatment. The dexpanthenol-containing artificial tears (Siccaprotect) improved disturbances of the corneal epithelial permeability significantly in comparison to the dexpanthenol-free eyes drops. The other parameters didn't show relevant differences. These data suggest that, in dry eyes, treatment with dexpanthenol-containing eye drops leads to a favorable and comparing with dexpanthenol-free eye drops superior improvement in disturbances of corneal epithelium permeability.

  1. On Biometrics With Eye Movements.

    PubMed

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  2. Comparison of the American Optical Vision Tester and the Armed Forces Far Visual Acuity Test. B-6-133-13

    DTIC Science & Technology

    1954-01-01

    THE AMERICAN OPTICAL VISION TESTER AND THE ARMED FORCES FAR VISUAL ACUITY TEST Comparisons were made of the visual acuity scores of 100 enlisted men on ...the American Optical Vision Tester (with Sloan plates) and on the Armed Forces Far Visual Acuity test. Order of presentation was: AO-left eye, AO...right eye, AFFVAT-left, AFVTAT-right. Correlation coefficients between AO and AFFVAT were around .89. Dispersion of acuity scores was about the same on

  3. Paralysis of the orbicularis muscle of the eye using botulinum toxin type A in the treatment for dry eye.

    PubMed

    Serna-Ojeda, Juan Carlos; Nava-Castaneda, Angel

    2017-03-01

    To evaluate the efficacy of botulinum toxin type A injection to cause orbicularis eyelid muscle paralysis to improve dry eye signs and symptoms. A prospective, randomized, comparative eye-to-eye and interventional study was performed. Patients with dry eye symptoms and positive fluorescein corneal staining were included. Randomly one eyelid received a subcutaneous injection of botulinum toxin in the medial orbicularis muscle portion of the lower eyelid, and the other eye received placebo. The subjective evaluation was achieved with a questionnaire assessing symptoms, quality of vision and ocular comfort level. The objective evaluation included the measurement of the tear film break-up time (TBUT), Schirmer's test and corneal and conjunctival staining. Twenty patients were included with a mean age of 59.5 years. Two weeks after the botulinum toxin injection, all patients showed a decrease in the horizontal movement of the lower eyelid when blinking. The eyes in the active treatment group showed better scores compared with the sham group in four symptoms 4 weeks after the treatment. The TBUT was higher at 1 and 3 months in the active treatment group. The corneal and conjunctival staining were significantly lower in the active treatment group at 1 and 3 months, and the Schirmer's test showed better measurements in the same group at 2 weeks, 1 month and 3 months. There were no adverse events reported. The injection of botulinum toxin A in the medial part of the lower eyelid is an effective and safe procedure that temporally improves some of the signs and symptoms of patients with dry eye. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Eye Donation Awareness and Conversion Rate in Hospital Cornea Retrieval Programme in a Tertiary Hospital of Central India

    PubMed Central

    Shrivastava, Ulka; Kumar, Kavita; Baghel, Rajendra; Khan, Farhana; Kulkarni, Shridhar

    2017-01-01

    Introduction Corneal blindness accounts for 6–8 million blinds in the world. In India, it is estimated that there are approximately 6.8 million people who have vision less than 6/60 in at least one eye due to corneal diseases. Aim This study was done to assess the awareness about eye donation amongst attendants of critically ill and deceased patients, their willingness to donate eyes, the efficacy of grief counselling by Eye Donation Counsellors (EDC), its impact on the conversion rate and the reasons for poor donation rate. Materials and Methods This prospective hospital based study was done in 554 participants (guardians of critically ill and deceased subjects) to understand the awareness of eye donation. Factors related to willingness for eye donation that influenced conversion to actual donation were evaluated. Data was analysed with tests for statistical significance: Chi square test; p<0.05 at 95% confidence interval was set as significant. Results Awareness index particularly in males <40 years, was found to be statistically more. In participants who were partially/fully aware of eye-donation, time taken for motivation remained less than 12 hours, which was statistically significant (Chi square=106. p<0.001). Subject who were aware, willing for donation in comparison to those who were unaware in a ratio of 2:1. Grief counsellors (57.5%) had the most influence among the causes that were facilitators of donation. Conclusion Utilizing the services of eye donation counsellors is a promising way to motivate the guardians of deceased. Increasing the awareness in society, rendering simple assistances to next of kin and speeding the medico legal formalities can go a long way in increasing the conversion rate and hence actual donation. PMID:28969171

  5. Eye Donation Awareness and Conversion Rate in Hospital Cornea Retrieval Programme in a Tertiary Hospital of Central India.

    PubMed

    Sharma, Bhavana; Shrivastava, Ulka; Kumar, Kavita; Baghel, Rajendra; Khan, Farhana; Kulkarni, Shridhar

    2017-08-01

    Corneal blindness accounts for 6-8 million blinds in the world. In India, it is estimated that there are approximately 6.8 million people who have vision less than 6/60 in at least one eye due to corneal diseases. This study was done to assess the awareness about eye donation amongst attendants of critically ill and deceased patients, their willingness to donate eyes, the efficacy of grief counselling by Eye Donation Counsellors (EDC), its impact on the conversion rate and the reasons for poor donation rate. This prospective hospital based study was done in 554 participants (guardians of critically ill and deceased subjects) to understand the awareness of eye donation. Factors related to willingness for eye donation that influenced conversion to actual donation were evaluated. Data was analysed with tests for statistical significance: Chi square test; p<0.05 at 95% confidence interval was set as significant. Awareness index particularly in males <40 years, was found to be statistically more. In participants who were partially/fully aware of eye-donation, time taken for motivation remained less than 12 hours, which was statistically significant (Chi square=106. p<0.001). Subject who were aware, willing for donation in comparison to those who were unaware in a ratio of 2:1. Grief counsellors (57.5%) had the most influence among the causes that were facilitators of donation. Utilizing the services of eye donation counsellors is a promising way to motivate the guardians of deceased. Increasing the awareness in society, rendering simple assistances to next of kin and speeding the medico legal formalities can go a long way in increasing the conversion rate and hence actual donation.

  6. The role of thyroid eye disease and other factors in the overcorrection of hypotropia following unilateral adjustable suture recession of the inferior rectus (an American Ophthalmological Society thesis).

    PubMed

    Kerr, Natalie C

    2011-12-01

    Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4-35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1-33.5, P=0.041). After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection.

  7. The Role of Thyroid Eye Disease and Other Factors in the Overcorrection of Hypotropia Following Unilateral Adjustable Suture Recession of the Inferior Rectus (An American Ophthalmological Society Thesis)

    PubMed Central

    Kerr, Natalie C.

    2011-01-01

    Purpose Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. Methods A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Results Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4–35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1–33.5, P=0.041). Conclusions After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection. PMID:22253487

  8. Tests of the E-Z Reader Model: Exploring the Interface between Cognition and Eye-Movement Control

    ERIC Educational Resources Information Center

    Pollatsek, Alexander; Reichle, Erik D.; Rayner, Keith

    2006-01-01

    This paper is simultaneously a test and refinement of the E-Z Reader model and an exploration of the interrelationship between visual and language processing and eye-movements in reading. Our modeling indicates that the assumption that words in text are processed serially by skilled readers is a viable and attractive hypothesis, as it accounts not…

  9. Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.

    PubMed

    Gulati, Shilpa; Jain, Sandeep

    2017-01-01

    Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.

  10. [Comparison of two kinds of artificial tears on the dry eye after phacoemulsification].

    PubMed

    You, R; Wang, J; Han, Y; Liu, L J; Wang, W Y

    2017-06-11

    Objective: To compare the curative effect of two different artificial tears on dry eye after phacoemulsification. Methods: Prospective randomized controlled clinical trial. From March to June in 2012, 102 patients (102 eyes) with age-related cataract were treated with phacoemulsification at Beijing Tongren Hospital, Capital University of Medical Sciences, and these eyes were randomly divided into blank group (group A ) 32 cases, treatment group 1 (group B) 35 cases and treatment group 2 (group C) 35 cases. Group A was treated with conventional antibiotics. Group B was sodium hyaluronate eye drop, group C was lipid-containing carbomer gel respectively. All patients finished a dry eye questionnaire called Ocular Surface Disease Index (OSDI), and Schimmer's test (SIt), break up time (BUT) and fluorescein staining (FL) tests were performed before surgery and at 7, 30 and 90 days after surgery respectively. Optometry were performed at 90 days after surgery. The χ(2) test was used to analyze the sex of the patients, and the age of the patients was analyzed by one-way ANOVA. Partial data in eye tests and in OSDI does not meet the normal distribution. Therefore, they were analyzed by Kruskal-Wallis H test. If significant difference existed, these data were then analyzed by independent sample Wilcoxon rank sum test. Results: Twelve patients were lost to visit within 3 months. A total of 90 patients were followed up for 90 days. The mean age of all patients was (69.5±9.5) years (46.0-89.0 years), 38 males and 64 females. There were 30 patients in Group A, group B and group C respectively. The prevalence of dry eye was 56. 7% (60/102). There was no significant difference among the three groups ( P> 0.05). OSDI questionnaire showed that OSDI score was significantly different among the three groups at 7, 30 and 90 days after operation ( H =9.89, 55.53, 45.43, P< 0.05). At 30 and 90 days after operation, the median OSDI scores were 12.50 and 10.42 in group C, respectively, which were better than those of group A scores 27.09 and 20. 8 ( Z=- 6.30, -5.94, P< 0.05), and were better than those of group B scores 17.71 and 13. 54 ( Z=- 3.40, -3.52, P< 0.05). At 90 days after operation, the median BUT of B and C treatment groups was 9. 00, which was better than that of group A (4.00). The difference was statistically significant ( H =21.51, P< 0.05), There was no significant difference between group B and group C ( Z=- 0.34, P> 0.05). Conclusion: The treatment of artificial tears with lipid composition in the early stage after phacoemulsification is beneficial to the improvement of postoperative symptoms and signs of dry eye. (Chin J Ophthalmol, 2017, 53: 445-450) .

  11. Effect of Oral Pilocarpine in Treating Severe Dry Eye in Patients With Sjögren Syndrome.

    PubMed

    Kawakita, Tetsuya; Shimmura, Shigeto; Tsubota, Kazuo

    2015-01-01

    The aim of this study is to evaluate the efficacy and safety of oral pilocarpine in treating severe dry eye unresponsive to conventional conservative treatment in patients with Sjögren syndrome. A prospective study. Oral doses of pilocarpine were administered for at least 3 months to patients with Sjögren syndrome complicated by established dry eye of great severity unresponsive to conventional conservative treatment. Subjective eye symptoms (dry eye sensation and eye pain), fluorescein staining scores, rose Bengal staining scores, and tear film breakup time measurements improved significantly after 1 month and 3 months of oral treatment with pilocarpine, whereas no significant improvement was noted in Schirmer I testing. Oral administration of pilocarpine was useful in treating severe dry eye unresponsive to conventional conservative treatment in patients with Sjögren syndrome from the standpoint of efficacy and safety. Thus, we conclude that oral pilocarpine is effective as a new option in treating severe dry eye.

  12. Determination of the toxicity of intravitreal minocycline in rabbit eyes.

    PubMed

    Falavarjani, Khalil Ghasemi; Pourhabibi, Arash; Aghdam, Kaveh Abri; Hosseini, Seyed Bagher; Modarres, Mehdi; Pazouki, Abdolreza; Khanamiri, Hossein Nazari

    2016-09-01

    To evaluate the retinal toxicity of intravitreal minocycline in rabbit eyes. Intravitreal injection of minocycline with concentrations of 1000, 500, 250, 125 and 62.5 μg in 0.1 ml was performed in 10 New Zealand albino rabbits. Each concentration was injected into two rabbit eyes. For each dose, normal saline was injected in one contralateral eye and the other fellow eye remained non-injected. Electrophysiologic testing was performed before and 4 weeks after injections. The eyes were enucleated 4 weeks after injections and examined using light microscopy. The clinical examination was unremarkable after injections. Electroretinography recordings were significantly affected at all doses in at least one of the a- or b-waves of photopic or scotopic responses. Histopathologic examination revealed marked atrophy and loss of integrity in all retinal layers in all minocycline injected eyes. Contralateral eyes were normal. In our study, intravitreal minocycline was toxic to the retina in albino rabbits even at a concentration of 62.5 µg/0.1 ml.

  13. Integrating the Advanced Human Eye Model (AHEM) and optical instrument models to model complete visual optical systems inclusive of the typical or atypical eye

    NASA Astrophysics Data System (ADS)

    Donnelly, William J., III

    2012-06-01

    PURPOSE: To present a commercially available optical modeling software tool to assist the development of optical instrumentation and systems that utilize and/or integrate with the human eye. METHODS: A commercially available flexible eye modeling system is presented, the Advanced Human Eye Model (AHEM). AHEM is a module that the engineer can use to perform rapid development and test scenarios on systems that integrate with the eye. Methods include merging modeled systems initially developed outside of AHEM and performing a series of wizard-type operations that relieve the user from requiring an optometric or ophthalmic background to produce a complete eye inclusive system. Scenarios consist of retinal imaging of targets and sources through integrated systems. Uses include, but are not limited to, optimization, telescopes, microscopes, spectacles, contact and intraocular lenses, ocular aberrations, cataract simulation and scattering, and twin eye model (binocular) systems. RESULTS: Metrics, graphical data, and exportable CAD geometry are generated from the various modeling scenarios.

  14. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.

    PubMed

    Fortune, Brad; Demirel, Shaban; Zhang, Xian; Hood, Donald C; Patterson, Emily; Jamil, Annisa; Mansberger, Steven L; Cioffi, George A; Johnson, Chris A

    2007-03-01

    To compare the diagnostic performance of multifocal visual evoked potential (mfVEP) and standard automated perimetry (SAP), in eyes with high-risk ocular hypertension or early glaucoma. Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were evaluated. Subjects ranged in age from 37 to 87 (mean +/- SD: 61 +/- 11 years). Pattern-reversal mfVEPs were obtained by using VERIS (Electro-Diagnostic Imaging, San Mateo, CA) with a four-electrode array and were analyzed with custom software. SAP visual fields (SITA-standard; Carl Zeiss Meditec, Inc., Dublin, CA) were obtained within 22.3 +/- 27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph (HRT) images were obtained during one visit, which was within 24.8 +/- 50.4 days of the mfVEP and 33.1 +/- 62.9 days of the SAP visual field. Abnormalities on the mfVEP were defined by using a variety of cluster criteria: SAP with pattern standard deviation (PSD) P

  15. An eye model for uncalibrated eye gaze estimation under variable head pose

    NASA Astrophysics Data System (ADS)

    Hnatow, Justin; Savakis, Andreas

    2007-04-01

    Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.

  16. Children with autism spectrum disorder are skilled at reading emotion body language.

    PubMed

    Peterson, Candida C; Slaughter, Virginia; Brownell, Celia

    2015-11-01

    Autism is commonly believed to impair the ability to perceive emotions, yet empirical evidence is mixed. Because face processing may be difficult for those with autism spectrum disorder (ASD), we developed a novel test of recognizing emotion via static body postures (Body-Emotion test) and evaluated it with children aged 5 to 12 years in two studies. In Study 1, 34 children with ASD and 41 typically developing (TD) controls matched for age and verbal intelligence (VIQ [verbal IQ]) were tested on (a) our new Body-Emotion test, (b) a widely used test of emotion recognition using photos of eyes as stimuli (Baron-Cohen et al.'s "Reading Mind in the Eyes: Child" or RMEC [Journal of Developmental and Learning Disorders, 2001, Vol. 5, pp. 47-78]), (c) a well-validated theory of mind (ToM) battery, and (d) a teacher-rated empathy scale. In Study 2 (33 children with ASD and 31 TD controls), the RMEC test was simplified to the six basic human emotions. Results of both studies showed that children with ASD performed as well as their TD peers on the Body-Emotion test. Yet TD children outperformed the ASD group on ToM and on both the standard RMEC test and the simplified version. VIQ was not related to perceiving emotions via either body posture or eyes for either group. However, recognizing emotions from body posture was correlated with ToM, especially for children with ASD. Finally, reading emotions from body posture was easier than reading emotions from eyes for both groups. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The Walk on Floor Eyes Closed Tandem Step Test as a Quantitative Measure of Ataxia After Space Flight

    NASA Technical Reports Server (NTRS)

    Fisher, E. A.; Reschke, M. F.; Kofman, I. S.; Cerisano, J. M.; Lawrence, E. L.; Peters, B. T.; Bloomberg, J. J.; Harm, D. L.

    2010-01-01

    INTRODUCTION Posture and locomotion are among the functions most affected by space flight. Postflight ataxia can be quantified easily by using the walk on the floor line test with the eyes closed (WOFEC). Data from a modified WOFEC were obtained as part of an ongoing interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both postflight functional performance of astronauts and related physiological changes. METHODS Five astronauts with flight durations of 12 to 16 days participated in this study. Performance measurements were obtained in 2 preflight sessions, on landing day, and 1, 6, and 30 days after landing. The WOFEC test consisted of walking with the feet placed heel to toe in tandem, arms folded across the chest and eyes closed, for 10 steps. A trial was initiated after the eyes were closed and the front foot was aligned with the rear foot. The performance metric was the average percentage of correct steps completed over 3 trials. A step was not counted as correct if the crewmember sidestepped, opened eyes, or paused for more than 3 seconds between steps. Step accuracy was scored independently by 3 examiners. RESULTS Immediately after landing subjects seemed to be unaware of their foot position relative to their body or the floor. The percentage of correct steps was significantly decreased on landing day. Partial recovery was observed the next day, and full recovery to baseline on the sixth day post landing. CONCLUSION These data clearly demonstrate the sensorimotor challenges facing crewmembers after they return from space flight. Although this simple test is intended to complement the FTT battery of tests, it has some stand-alone value as it provides investigators with a means to quantify vestibular ataxia as well as provide instant feedback on postural stability without the use of complex test equipment.

  18. Therapeutic Effects of Sodium Hyaluronate on Ocular Surface Damage Induced by Benzalkonium Chloride Preserved Anti-glaucoma Medications

    PubMed Central

    Liu, Xing; Yu, Fen-Fen; Zhong, Yi-Min; Guo, Xin-Xing; Mao, Zhen

    2015-01-01

    Background: Long-term use of benzalkonium chloride (BAC)-preserved drugs is often associated with ocular surface toxicity. Ocular surface symptoms had a substantial impact on the glaucoma patients’ quality of life and compliance. This study aimed to investigate the effects of sodium hyaluronate (SH) on ocular surface toxicity induced by BAC-preserved anti-glaucoma medications treatment. Methods: Fifty-eight patients (101 eyes), who received topical BAC-preserved anti-glaucoma medications treatment and met the severe dry eye criteria, were included in the analysis. All patients were maintained the original topical anti-glaucoma treatment. In the SH-treated group (56 eyes), unpreserved 0.3% SH eye drops were administered with 3 times daily for 90 days. In the control group (55 eyes), phosphate-buffered saline were administered with 3 times daily for 90 days. Ocular Surface Disease Index (OSDI) questionnaire, break-up time (BUT) test, corneal fluorescein staining, corneal and conjunctival rose Bengal staining, Schirmer test, and conjunctiva impression cytology were performed sequentially on days 0 and 91. Results: Compared with the control group, SH-treated group showed decrease in OSDI scores (Kruskal-Wallis test: H = 38.668, P < 0.001), fluorescein and rose Bengal scores (Wilcoxon signed-ranks test: z = −3.843, P < 0.001, and z = −3.508, P < 0.001, respectively), increase in tear film BUT (t-test: t = −10.994, P < 0.001) and aqueous tear production (t-test: t = −10.328, P < 0.001) on day 91. The goblet cell density was increased (t-test: t = −9.981, P < 0.001), and the morphology of the conjunctival epithelium were also improved after SH treatment. Conclusions: SH significantly improved both symptoms and signs of ocular surface damage in patients with BAC-preserved anti-glaucoma medications treatment. SH could be proposed as a new attempt to reduce ocular surface toxicity, and alleviate symptoms of ocular surface damage in BAC-preserved anti-glaucoma medications treatment. PMID:26365960

  19. Eye Choice for Acquisition of Targets in Alternating Strabismus

    PubMed Central

    Economides, John R.; Adams, Daniel L.

    2014-01-01

    In strabismus, potentially either eye can inform the brain about the location of a target so that an accurate saccade can be made. Sixteen human subjects with alternating exotropia were tested dichoptically while viewing stimuli on a tangent screen. Each trial began with a fixation cross visible to only one eye. After the subject fixated the cross, a peripheral target visible to only one eye flashed briefly. The subject's task was to look at it. As a rule, the eye to which the target was presented was the eye that acquired the target. However, when stimuli were presented in the far nasal visual field, subjects occasionally performed a “crossover” saccade by placing the other eye on the target. This strategy avoided the need to make a large adducting saccade. In such cases, information about target location was obtained by one eye and used to program a saccade for the other eye, with a corresponding latency increase. In 10/16 subjects, targets were presented on some trials to both eyes. Binocular sensory maps were also compiled to delineate the portions of the visual scene perceived with each eye. These maps were compared with subjects' pattern of eye choice for target acquisition. There was a correspondence between suppression scotoma maps and the eye used to acquire peripheral targets. In other words, targets were fixated by the eye used to perceive them. These studies reveal how patients with alternating strabismus, despite eye misalignment, manage to localize and capture visual targets in their environment. PMID:25355212

  20. Corneal transplant

    MedlinePlus

    ... and prevent eye movement during the surgery. The tissue for your corneal transplant will come from a person (donor) who has recently died. The donated cornea is processed and tested by a local eye bank to make sure it is safe for use ...

  1. Eye tracking reveals a crucial role for facial motion in recognition of faces by infants.

    PubMed

    Xiao, Naiqi G; Quinn, Paul C; Liu, Shaoying; Ge, Liezhong; Pascalis, Olivier; Lee, Kang

    2015-06-01

    Current knowledge about face processing in infancy comes largely from studies using static face stimuli, but faces that infants see in the real world are mostly moving ones. To bridge this gap, 3-, 6-, and 9-month-old Asian infants (N = 118) were familiarized with either moving or static Asian female faces, and then their face recognition was tested with static face images. Eye-tracking methodology was used to record eye movements during the familiarization and test phases. The results showed a developmental change in eye movement patterns, but only for the moving faces. In addition, the more infants shifted their fixations across facial regions, the better their face recognition was, but only for the moving faces. The results suggest that facial movement influences the way faces are encoded from early in development. (c) 2015 APA, all rights reserved).

  2. Scene perception and memory revealed by eye movements and receiver-operating characteristic analyses: does a cultural difference truly exist?

    PubMed

    Evans, Kris; Rotello, Caren M; Li, Xingshan; Rayner, Keith

    2009-02-01

    Cultural differences have been observed in scene perception and memory: Chinese participants purportedly attend to the background information more than did American participants. We investigated the influence of culture by recording eye movements during scene perception and while participants made recognition memory judgements. Real-world pictures with a focal object on a background were shown to both American and Chinese participants while their eye movements were recorded. Later, memory for the focal object in each scene was tested, and the relationship between the focal object (studied, new) and the background context (studied, new) was manipulated. Receiver-operating characteristic (ROC) curves show that both sensitivity and response bias were changed when objects were tested in new contexts. However, neither the decrease in accuracy nor the response bias shift differed with culture. The eye movement patterns were also similar across cultural groups. Both groups made longer and more fixations on the focal objects than on the contexts. The similarity of eye movement patterns and recognition memory behaviour suggests that both Americans and Chinese use the same strategies in scene perception and memory.

  3. Bilateral Symmetry of Visual Function Loss in Cone-Rod Dystrophies.

    PubMed

    Galli-Resta, Lucia; Falsini, Benedetto; Rossi, Giuseppe; Piccardi, Marco; Ziccardi, Lucia; Fadda, Antonello; Minnella, Angelo; Marangoni, Dario; Placidi, Giorgio; Campagna, Francesca; Abed, Edoardo; Bertelli, Matteo; Zuntini, Monia; Resta, Giovanni

    2016-07-01

    To investigate bilateral symmetry of visual impairment in cone-rod dystrophy (CRD) patients and understand the feasibility of clinical trial designs treating one eye and using the untreated eye as an internal control. This was a retrospective study of visual function loss measures in 436 CRD patients followed at the Ophthalmology Department of the Catholic University in Rome. Clinical measures considered were best-corrected visual acuity, focal macular cone electroretinogram (fERG), and Ganzfeld cone-mediated and rod-mediated electroretinograms. Interocular agreement in each of these clinical indexes was assessed by t- and Wilcoxon tests for paired samples, structural (Deming) regression analysis, and intraclass correlation. Baseline and follow-up measures were analyzed. A separate analysis was performed on the subset of 61 CRD patients carrying likely disease-causing mutations in the ABCA4 gene. Statistical tests show a very high degree of bilateral symmetry in the extent and progression of visual impairment in the fellow eyes of CRD patients. These data contribute to a better understanding of CRDs and support the feasibility of clinical trial designs involving unilateral eye treatment with the use of fellow eye as internal control.

  4. Gender discrimination of eyes and mouths by individuals with autism.

    PubMed

    Best, Catherine A; Minshew, Nancy J; Strauss, Mark S

    2010-04-01

    Evidence remains mixed about whether individuals with autism look less to eyes and whether they look more at mouths. Few studies have examined how spontaneous attention to facial features relates to face processing abilities. This study tested the ability to discriminate gender from facial features, namely eyes and mouths, by comparing accuracy scores of 17 children with autism and 15 adults with autism to 17 typically developing children and 15 typically developing adults. Results indicated that all participants regardless of diagnosis discriminated gender more accurately from eyes than from mouths. However, results indicated that compared to adults without autism, adults with autism were significantly worse at discriminating gender from eyes.

  5. Comparison Between Botulinum Toxin A Injection and Lacrimal Punctal Plugs for the Control of Post-LASIK Dry Eye Manifestations: A Prospective Study.

    PubMed

    Fouda, Sameh M; Mattout, Hala K

    2017-06-01

    Laser in situ keratomelieusis (LASIK) is one of the commonest refractive procedures performed nowadays. The dry eye problem is nearly universal in all patients after LASIK and it can be so annoying that the post-operative patient satisfaction is sometimes precluded. Conventional treatment includes the use of artificial tears. Alternative methods such as punctal plugs and botulinum toxin injection can be used for the management of post-LASIK dry eye. The aim of this study is to compare botulinum toxin injection in the orbicularis muscle to lacrimal punctal plugs for the control of post-LASIK dry eye manifestations. This is a prospective study that included 60 patients who had LASIK eye surgery for correction of refractive errors. Patients were randomly assigned to one of three methods of dry eye management; the first method was conventional medical treatment with preservative-free tear substitutes only (group A: 20 patients = 40 eyes); the second method was intraoperative injection of botulinum toxin A (BTA) in the orbicularis muscle below the lower punctum of both eyes (group B: 20 patients = 40 eyes) and the third method was intraoperative insertion of temporary extended duration silicone punctal plugs in the lower punctum of both eyes (group C: 20 patients = 40 eyes). In the first follow-up visit after 2 weeks, the two test groups (B, C) showed a statistically significant increase in both tear film break up time (TBUT) and Schirmer test score with a decrease in the OSDI score and daily frequency of lubricants used in comparison to the control group A. These differences were maintained in the next follow-up visit but they became statistically insignificant at the 3rd and 6th post-operative months. Complications were encountered more in the punctal plug patients (60%) than in BTA patients (25%) and this difference was statistically significant. The use of BTA injection to control dry eye symptoms by inducing temporary punctal ectropion is an effective method to improve patient satisfaction after LASIK eye surgery. It has higher level of patient satisfaction and fewer complications in comparison to punctal plugs or topical standard dry eye treatment.

  6. Falls and postural control in older adults with cataracts

    PubMed Central

    Nodehi Moghadam, Afsun; Goudarzian, Maryam; Azadi, Farhad; Hosseini, Seide Masume; Mosallanezhad, Zahra; Karimi, Nouraddin; Larne, Yassin; Habibi, Maryam; Yaghmaei, Poorya

    2015-01-01

    Background: There is increasing evidence that visual impairment contribute to falling. The aim of this study was to determine the influence of vision impairment of old adult patients with cataract on the occurrence of falls and postural control. Methods: According to the results of screening ophthalmic examination, 48 cataract patients (mean±SD aged 68.5 ± 6.08 yrs.) and 50 individuals without any obvious eye disorders (mean age ± SD 70.7 ± 5.97 yrs.) were enrolled in this study. The postural control was determined using the clinical test of Sensory Interaction and Balance (CTSIB) and Timed up and Go (TUG) test. Results: The results of this study revealed that 18% (n = 9) of the normal individuals and 22.9% (n =11) of the cataract patients had at least two falls in the past 12 months. However, the result of chisquare test did not show any differences between the two groups (p= 0.36). The mean ± SD TUG times in cataract and control groups in our study were15.17 ± 3.58 and13.77 ± 4.90, respectively. However, no significant differences were found between the two groups (p= 0.12).The results of CTSIB test showed no significant differences between the two groups on standing on the floor with eyes open and eyes closed (p= 0.61, p= 0.89) and on standing on the foam with eyes open and eyes closed (p= 0.32, p= 0.74 ). Conclusion: According to the results of CTSIB and TUG tests, vision impairment of old adult patients with cataract is not associated with falls and balance disorders. Further work including assessment of postural control with advanced devices and considering other falls risk factors are also required to identify predictors of falls in cataract patients. PMID:26913274

  7. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  8. Effectiveness of Autologous Serum Eye Drops Combined With Punctal Plugs for the Treatment of Sjögren Syndrome-Related Dry Eye.

    PubMed

    Liu, Ying; Hirayama, Masatoshi; Cui, Xin; Connell, Samuel; Kawakita, Tetsuya; Tsubota, Kazuo

    2015-10-01

    To evaluate the efficacy and safety of autologous serum (AS) eye drops combined with punctal plugs (PPs) in patients with Sjögren syndrome (SS)-related dry eye. A retrospective clinical study was performed in patients with dry eye caused by SS. We evaluated the Schirmer test value, tear breakup time (tBUT), and fluorescein and Rose Bengal (RB) staining scores at baseline, 3 months, 6 months, 1 year, and >1 year after treatment. The dry eye indexes were also evaluated in 2 subgroups, which determined by the using of PPs, including the AS + PP group and AS only group. A total of 56 eyes of 28 patients were investigated with a mean follow-up of 42.3 ± 26.1 months. After the application of AS eye drops, the Schirmer test showed no significant changes. The tBUT (2.7 ± 1.9 seconds) was significantly improved at each time point (3.9 ± 3.1, 4.5 ± 3.1, 3.7 ± 2.5, and 5.1 ± 4.0; P < 0.01), fluorescein staining (4.3 ± 2.8) was significantly improved at each time point (2.2 ± 2.2, 1.9 ± 1.9, 1.8 ± 1.6, and 1.8 ± 1.8; P < 0.01), and RB (2.6 ± 3.0) staining was significantly improved from 6-month treatment (1.5 ± 1.9, 1.9 ± 1.9, and 1.4 ± 1.8; P < 0.05, 0.01, and 0.01, respectively). When combined with PPs, the tBUT and RB staining scores were found to be significantly improved in the AS + PP group compared with those of the AS only group. Long-term application of AS eye drops was found to be an effective and apparently safe treatment for SS dry eye. Furthermore, PPs in combination with AS eye drops were considered to have an additive effect on SS dry eye.

  9. A thermographic study on eyes affected by Age-related Macular Degeneration: Comparison among various forms of the pathology and analysis of risk factors

    NASA Astrophysics Data System (ADS)

    Matteoli, Sara; Finocchio, Lucia; Biagini, Ilaria; Giacomelli, Giovanni; Sodi, Andrea; Corvi, Andrea; Virgili, Gianni; Rizzo, Stanislao

    2016-05-01

    The aims of this study are to investigate (1) the ocular thermographic profiles in eyes affected by Age related Macular Degeneration (AMD) and age-matched controls to detect possible hemodynamic abnormalities that could be involved in the pathogenesis of the disease, (2) whether any risk factors associated with the disease could affect the development of a form of AMD rather than another. Thirty-four eyes with Age-Related Maculopathy (ARM), 41 eyes with dry AMD, 60 eyes affected by wet AMD, and 74 eyes with fibrotic AMD were included in the study. The control group consisted of 48 healthy eyes. Exclusion criteria were represented by any other ocular diseases other than AMD, tear film abnormalities, systemic cardiovascular abnormalities, systemic diseases and a body temperature higher than 37.5 °C. A total of 210 eyes without pupil dilation were investigated by infrared thermography (FLIR A320). The Ocular Surface Temperature (OST) of five ocular areas was calculated by means of an image processing technique from the infrared images. Two-sample t-test, one-way ANOVA test and multivariate analysis were used for statistical analyses. ANOVA analyses showed no significant differences among AMD groups (P-value > 0.05), however, OST in AMD patients was significantly lower than in controls (P-value < 0.0001). Smokers showed higher possibility (P-value = 0.012) of developing wet AMD instead of dry AMD. Infrared thermography may be a helpful, non-invasive and not time-consuming method to be used in the management of patients with this common degenerative maculopathy.

  10. Distinct eye movement patterns enhance dynamic visual acuity.

    PubMed

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  11. Distinct eye movement patterns enhance dynamic visual acuity

    PubMed Central

    Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157

  12. A Comprehensive Review of Sex Disparities in Symptoms, Pathophysiology, and Epidemiology of Dry Eye Syndrome.

    PubMed

    Rapoport, Yuna; Singer, Jason M; Ling, Jeanie D; Gregory, Anthony; Kohanim, Sahar

    2016-01-01

    The etiology, frequency, manifestation, and treatment of dry eye syndrome are commonly influenced by sex and gender. This study aims to review the differences in epidemiology, pathophysiology, and associated diseases between the sexes. The terms men and male and women and female are used interchangeably throughout the review to refer to biological sex. There are numerous objective and subjective markers of dry eye syndrome but not one diagnostic criterion. There are numerous associated conditions with dry eye syndrome varying from autoimmune to allergic. Large epidemiologic studies reviewed suggest that there does indeed exist a difference between dry eye symptoms between men and women, with women having dry eye signs and reporting dry eye symptoms more often than men. The increased prevalence in women could be correlated to an increased association with certain systemic diseases, specifically autoimmune diseases, and to hormonal variations. Several studies found equivocal data about prevalence of dry eye symptoms between men and women. Interpreting studies that investigate epidemiology, pathogenesis, and treatment of dry-eye conditions is complicated by the lack of universally adapted diagnostic criteria and standardized, specific diagnostic tests, and inter-study variability in the definition of dry eye syndrome.

  13. Human Commercial Models' Eye Colour Shows Negative Frequency-Dependent Selection.

    PubMed

    Forti, Isabela Rodrigues Nogueira; Young, Robert John

    2016-01-01

    In this study we investigated the eye colour of human commercial models registered in the UK (400 female and 400 male) and Brazil (400 female and 400 male) to test the hypothesis that model eye colour frequency was the result of negative frequency-dependent selection. The eye colours of the models were classified as: blue, brown or intermediate. Chi-square analyses of data for countries separated by sex showed that in the United Kingdom brown eyes and intermediate colours were significantly more frequent than expected in comparison to the general United Kingdom population (P<0.001). In Brazil, the most frequent eye colour brown was significantly less frequent than expected in comparison to the general Brazilian population. These results support the hypothesis that model eye colour is the result of negative frequency-dependent selection. This could be the result of people using eye colour as a marker of genetic diversity and finding rarer eye colours more attractive because of the potential advantage more genetically diverse offspring that could result from such a choice. Eye colour may be important because in comparison to many other physical traits (e.g., hair colour) it is hard to modify, hide or disguise, and it is highly polymorphic.

  14. Measurement of central corneal thickness with optical low-coherence reflectometry and ultrasound pachymetry in normal and post-femtosecond laser in situ keratomileusis eyes.

    PubMed

    Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei

    2015-02-01

    To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.

  15. Fluctuation of Bacteria on Bleb Surface After Trabeculectomy With Adjunctive Mitomycin C.

    PubMed

    Takahashi, Nobumichi; Sawada, Akira; Mochizuki, Kiyofumi; Katada, Toshihiko; Yamamoto, Tetsuya

    2016-05-01

    To determine whether the bacterial and floral patterns on the bleb surface are affected by the season in eyes that had undergone trabeculectomy with adjunctive mitomycin C. Forty-four glaucoma patients who had an avascular or a hypovascular cystic filtering bleb were studied. Swabs of the bleb surface were taken 4 times in 1 year. The samples were cultured, and all organisms isolated were identified and tested for antibiotic sensitivity and resistance. Of the 176 specimens, 48 tested positive in cultures. Out of the 44 glaucoma eyes that had undergone trabeculectomy, 30 (68.2%) eyes were culture positive. A total of 58 strains were isolated. The organisms isolated were 22 strains of Staphylococcus epidermidis, 21 strains of Propionibacterium acnes, 8 strains of Corynebacterium sp., 5 strains of Staphylococcus sp., and 1 strain of both Neisseria sp., and Candida parapsilosis. Fifteen eyes had a positive culture ≥2 times, and in 10 of these eyes, the same strain was isolated. There was no resistance to vancomycin by S. epidermidis, P. acnes, and Corynebacterium sp. All of the isolates of S.epidermidis were sensitive to minocycline and amikacin. The rate of bacterial detection in the spring was 13.6%, summer was 20.5%, autumn was 45.5%, and winter was 29.5%. The increase in the incidence of bacterial presence during autumn was significant (P=0.006; the Fisher exact probability test). It is not rare to detect the bacterial organisms on the bleb surface in glaucomatous eyes that had undergone trabeculectomy. The prevalence varied with the season and was highest in the autumn.

  16. Acquired color vision and visual field defects in patients with ocular hypertension and early glaucoma.

    PubMed

    Papaconstantinou, Dimitris; Georgalas, Ilias; Kalantzis, George; Karmiris, Efthimios; Koutsandrea, Chrysanthi; Diagourtas, Andreas; Ladas, Ioannis; Georgopoulos, Gerasimos

    2009-01-01

    To study acquired color vision and visual field defects in patients with ocular hypertension (OH) and early glaucoma. In a prospective study we evaluated 99 eyes of 56 patients with OH without visual field defects and no hereditary color deficiencies, followed up for 4 to 6 years (mean = 4.7 +/- 0.6 years). Color vision defects were studied using a special computer program for Farnsworth-Munsell 100 hue test and visual field tests were performed with Humphrey analyzer using program 30-2. Both tests were repeated every six months. In fifty-six eyes, glaucomatous defects were observed during the follow-up period. There was a statistically significant difference in total error score (TES) between eyes that eventually developed glaucoma (157.89 +/- 31.79) and OH eyes (75.51 +/- 31.57) at the first examination (t value 12.816, p < 0.001). At the same time visual field indices were within normal limits in both groups. In the glaucomatous eyes the earliest statistical significant change in TES was identified at the first year of follow-up and was -20.62 +/- 2.75 (t value 9.08, p < 0.001) while in OH eyes was -2.11 +/- 4.36 (t value 1.1, p = 0.276). Pearson's coefficient was high in all examinations and showed a direct correlation between TES and mean deviation and corrected pattern standard deviation in both groups. Quantitative analysis of color vision defects provides the possibility of follow-up and can prove a useful means for detecting early glaucomatous changes in patients with normal visual fields.

  17. Dry eye findings worsen with anticholinergic therapy in patients with urge incontinence.

    PubMed

    Ozen Tunay, Zuhal; Ozdemir, Ozdemir; Ergintürk Acar, Damla; Cavkaytar, Sabri; Ersoy, Ebru

    2016-06-01

    To evaluate the effects of oral anticholinergic (OAC) drugs on tear secretion in women with overactive bladder over a 3-month follow-up period. In this prospective study, 108 women with a diagnosis of overactive bladder were evaluated. All patients were examined ophthalmologically at baseline (day 0), and after 1 month (day 30) and 3 months (day 90) of OAC treatment. Tear film break-up time (BUT) and Schirmer 1 test results were recorded. The subjective complaints of the patients including dry mouth, and burning, dryness and foreign body sensation in the eyes, were also recorded. The chi-squared test or the paired sample t test as appropriate, was used for statistical analysis. The mean age of the patients was 51.8 ± 9.2 years (30 - 69 years). The most frequent subjective complaints were dry mouth and dry eyes and both complaints were significant on both day 30 and day 90. Both tear film BUT and Schirmer 1 test results were significantly lower on day 30 and day 90. Dry eye measurement values worsened with prolongation of OAC treatment (p = 0.037 and p = 0.012 for BUT, and p = 0.046 and p = 0.035 for Schirmer 1 test, on day 30 and day 90, respectively). OAC treatment in women with overactive bladder significantly and progressively affects tear secretion.

  18. Metamorphopsia Score and Central Visual Field Outcomes in Diabetic Cystoid Macular Edema

    PubMed Central

    Brzozowska, Agnieszka; Maciejewski, Ryszard

    2018-01-01

    Aim To detect abnormality of the visual function in naïve patients with cystoid diabetic macular edema (DME) using M-charts, Amsler test, and white on white (W/W) and blue on yellow (B/Y) perimetry. Methods There were 64 eyes included in the study: 30 eyes with DME, 22 eyes with diabetes without DME, and 12 eyes of normal subjects. Conventional W/W perimetry and B/Y perimetry were performed within the central 10° of the visual field. To assess metamorphopsia, Amsler test and M-charts were used. Results The rate of detection of metamorphopsia was 37% with Amsler test examination and 50% with M-charts. Specificity of both tests was 100%. We found a significant difference between vertical scores of M-charts in all groups, but not in horizontal scores (p < 0.0001). Mean defect (MD) was 8.9 dB and 3.6 dB and loss variance (LV) 4.8 dB and 3.3 dB (p < 0.0001). Conclusions M-chart is more sensitive than Amsler test method for detection of metamorphopsia. The MD and LV are higher in b/y in comparison to W/W perimetry. B/Y perimetry and M-charts are more sensitive than conventional methods for detecting the visual function loss in cystoid DME. PMID:29744359

  19. Objective measurement of postocclusion surge during phacoemulsification in human eye-bank eyes.

    PubMed

    Georgescu, Dan; Payne, Marielle; Olson, Randall J

    2007-03-01

    To objectively compare the postocclusion vacuum surge among different phacoemulsification machines and devices. Experimental study. Infiniti, Legacy, Millennium, and Sovereign were tested in an eye-bank eye. All the machines were tested with 20-gauge non-ABS tips, 430 mm Hg vacuum pressure, 24 ml/minute aspiration rate, peristaltic pump, and 75 cm bottle height. In addition, Infiniti and Legacy were also tested with 20-gauge bypass tips (ABS), 125 cm bottle height, and 40 ml/minute flow rate. We also tested 19-gauge tips with Infiniti and Sovereign and the venturi pump for Millennium. Significant differences were found between all the machines tested with Millennium peristaltic generating the least and Millennium Venturi the most surge. ABS tips significantly decreased the surge for Legacy but not for Infiniti. Cruise Control (CC) had a significant effect on Sovereign but not on Millennium. Increasing the bottle height decreased surge while increasing the flow increased surge for both Infiniti and Legacy. The 19-gauge tips increased surge for both Infiniti and Sovereign. Surge varied over a range of 40 microm to more than 2 mm. ABS and CC decrease surge, especially when the machine is not functioning near the limits of surge prevention. Certain parameters, such as a 19-gauge tip and high flow, dramatically increased surge, whereas elevating the bottle ameliorates it. Understanding the impact of all these features will help in minimizing the problem.

  20. Influence of visual control, conduction, and central integration on static and dynamic balance in healthy older adults.

    PubMed

    Perrin, P P; Jeandel, C; Perrin, C A; Béné, M C

    1997-01-01

    Aging is associated with decreased balance abilities, resulting in an increased risk of fall. In order to appreciate the visual, somatosensory, and central signals involved in balance control, sophisticated methods of posturography assessment have been developed, using static and dynamic tests, eventually associated with electromyographic measurements. We applied such methods to a population of healthy older adults in order to appreciate the respective importance of each of these sensorial inputs in aging individuals. Posture control parameters were recorded on a force-measuring platform in 41 healthy young (age 28.5 +/- 5.9 years) and 50 older (age 69.8 +/- 5.9 years) adults, using a static test and two dynamic tests performed by all individuals first with eyes open, then with eyes closed. The distance covered by the center of foot pressure, sway area, and anteroposterior oscillations were significantly higher, with eyes open or closed, in older people than in young subjects. Significant differences were noted in dynamic tests with longer latency responses in the group of old people. Dynamic recordings in a sinusoidal test had a more regular pattern when performed eyes open in both groups and evidenced significantly greater instability in old people. These data suggest that vision remains important in maintaining postural control while conduction and central integration become less efficient with age.

Top