Polyakov loop modeling for hot QCD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukushima, Kenji; Skokov, Vladimir
Here, we review theoretical aspects of quantum chromodynamics (QCD) at finite temperature. The most important physical variable to characterize hot QCD is the Polyakov loop, which is an approximate order parameter for quark deconfinement in a hot gluonic medium. Additionally to its role as an order parameter, the Polyakov loop has rich physical contents in both perturbative and non-perturbative sectors. This review covers a wide range of subjects associated with the Polyakov loop from topological defects in hot QCD to model building with coupling to the Polyakov loop.
Polyakov loop modeling for hot QCD
Fukushima, Kenji; Skokov, Vladimir
2017-06-19
Here, we review theoretical aspects of quantum chromodynamics (QCD) at finite temperature. The most important physical variable to characterize hot QCD is the Polyakov loop, which is an approximate order parameter for quark deconfinement in a hot gluonic medium. Additionally to its role as an order parameter, the Polyakov loop has rich physical contents in both perturbative and non-perturbative sectors. This review covers a wide range of subjects associated with the Polyakov loop from topological defects in hot QCD to model building with coupling to the Polyakov loop.
Phase structure of the Polyakov-quark-meson model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer, B.-J.; Pawlowski, J. M.; Wambach, J.
2007-10-01
The relation between the deconfinement and chiral phase transition is explored in the framework of a Polyakov-loop-extended two-flavor quark-meson (PQM) model. In this model the Polyakov loop dynamics is represented by a background temporal gauge field which also couples to the quarks. As a novelty an explicit quark chemical potential and N{sub f}-dependence in the Polyakov loop potential is proposed by using renormalization group arguments. The behavior of the Polyakov loop as well as the chiral condensate as function of temperature and quark chemical potential is obtained by minimizing the grand canonical thermodynamic potential of the system. The effect ofmore » the Polyakov loop dynamics on the chiral phase diagram and on several thermodynamic bulk quantities is presented.« less
Three flavor Nambu-Jona-Lasinio model with Polyakov loop and competition with nuclear matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ciminale, M.; Ippolito, N. D.; Nardulli, G.
2008-03-01
We study the phase diagram of the three flavor Polyakov-Nambu-Jona-Lasinio (PNJL) model and, in particular, the interplay between chiral symmetry restoration and deconfinement crossover. We compute chiral condensates, quark densities, and the Polyakov loop at several values of temperature and chemical potential. Moreover we investigate on the role of the Polyakov loop dynamics in the transition from nuclear matter to quark matter.
Polyakov loop correlator in perturbation theory
Berwein, Matthias; Brambilla, Nora; Petreczky, Péter; ...
2017-07-25
We study the Polyakov loop correlator in the weak coupling expansion and show how the perturbative series re-exponentiates into singlet and adjoint contributions. We calculate the order g 7 correction to the Polyakov loop correlator in the short distance limit. We show how the singlet and adjoint free energies arising from the re-exponentiation formula of the Polyakov loop correlator are related to the gauge invariant singlet and octet free energies that can be defined in pNRQCD, namely we find that the two definitions agree at leading order in the multipole expansion, but differ at first order in the quark-antiquark distance.
Polyakov loop correlator in perturbation theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berwein, Matthias; Brambilla, Nora; Petreczky, Péter
We study the Polyakov loop correlator in the weak coupling expansion and show how the perturbative series re-exponentiates into singlet and adjoint contributions. We calculate the order g 7 correction to the Polyakov loop correlator in the short distance limit. We show how the singlet and adjoint free energies arising from the re-exponentiation formula of the Polyakov loop correlator are related to the gauge invariant singlet and octet free energies that can be defined in pNRQCD, namely we find that the two definitions agree at leading order in the multipole expansion, but differ at first order in the quark-antiquark distance.
Lattice QCD analysis for relation between quark confinement and chiral symmetry breaking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doi, Takahiro M.; Suganuma, Hideo; Iritani, Takumi
2016-01-22
The Polyakov loop and the Dirac modes are connected via a simple analytical relation on the temporally odd-number lattice, where the temporal lattice size is odd with the normal (nontwisted) periodic boundary condition. Using this relation, we investigate the relation between quark confinement and chiral symmetry breaking in QCD. In this paper, we discuss the properties of this analytical relation and numerically investigate each Dirac-mode contribution to the Polyakov loop in both confinement and deconfinement phases at the quenched level. This relation indicates that low-lying Dirac modes have little contribution to the Polyakov loop, and we numerically confirmed this fact.more » From our analysis, it is suggested that there is no direct one-to-one corresponding between quark confinement and chiral symmetry breaking in QCD. Also, in the confinement phase, we numerically find that there is a new “positive/negative symmetry” in the Dirac-mode matrix elements of link-variable operator which appear in the relation and the Polyakov loop becomes zero because of this symmetry. In the deconfinement phase, this symmetry is broken and the Polyakov loop is non-zero.« less
Polyakov loop fluctuations in the presence of external fields
NASA Astrophysics Data System (ADS)
Lo, Pok Man; Szymański, Michał; Redlich, Krzysztof; Sasaki, Chihiro
2018-06-01
We study the implications of the spontaneous and explicit Z(3) center symmetry breaking for the Polyakov loop susceptibilities. To this end, ratios of the susceptibilities of the real and imaginary parts, as well as of the modulus of the Polyakov loop are computed within an effective model using a color group integration scheme. We show that the essential features of the lattice QCD results of these ratios can be successfully captured by the effective approach. Furthermore we discuss a novel scaling relation in one of these ratios involving the explicit breaking field, volume, and temperature.
Renormalized Polyakov loop in the deconfined phase of SU(N) gauge theory and gauge-string duality.
Andreev, Oleg
2009-05-29
We use gauge-string duality to analytically evaluate the renormalized Polyakov loop in pure Yang-Mills theories. For SU(3), the result is in quite good agreement with lattice simulations for a broad temperature range.
Constituent Quarks and Gluons, Polyakov loop and the Hadron Resonance Gas Model ***
NASA Astrophysics Data System (ADS)
Megías, E.; Ruiz Arriola, E.; Salcedo, L. L.
2014-03-01
Based on first principle QCD arguments, it has been argued in [1] that the vacuum expectation value of the Polyakov loop can be represented in the hadron resonance gas model. We study this within the Polyakov-constituent quark model by implementing the quantum and local nature of the Polyakov loop [2, 3]. The existence of exotic states in the spectrum is discussed. Presented by E. Megías at the International Nuclear Physics Conference INPC 2013, 2-7 June 2013, Firenze, Italy.Supported by Plan Nacional de Altas Energías (FPA2011-25948), DGI (FIS2011-24149), Junta de Andalucía grant FQM-225, Spanish Consolider-Ingenio 2010 Programme CPAN (CSD2007-00042), Spanish MINECO's Centro de Excelencia Severo Ochoa Program grant SEV-2012-0234, and the Juan de la Cierva Program.
Chiral and deconfinement phase transition in the Hamiltonian approach to QCD in Coulomb gauge
NASA Astrophysics Data System (ADS)
Reinhardt, H.; Vastag, P.
2016-11-01
The chiral and deconfinement phase transitions are investigated within the variational Hamiltonian approach to QCD in Coulomb gauge. The temperature β-1 is introduced by compactifying a spatial dimension. Thereby the whole temperature dependence is encoded in the vacuum state on the spatial manifold R2×S1(β ) . The chiral quark condensate and the dual quark condensate (dressed Polyakov loop) are calculated as a function of the temperature. From their inflection points the pseudocritical temperatures for the chiral and deconfinement crossover transitions are determined. Using the zero-temperature quark and gluon propagators obtained within the variational approach as input, we find 170 and 198 MeV, respectively, for the chiral and deconfinement transition.
Confronting effective models for deconfinement in dense quark matter with lattice data
NASA Astrophysics Data System (ADS)
Andersen, Jens O.; Brauner, Tomáš; Naylor, William R.
2015-12-01
Ab initio numerical simulations of the thermodynamics of dense quark matter remain a challenge. Apart from the infamous sign problem, lattice methods have to deal with finite volume and discretization effects as well as with the necessity to introduce sources for symmetry-breaking order parameters. We study these artifacts in the Polyakov-loop-extended Nambu-Jona-Lasinio (PNJL) model and compare its predictions to existing lattice data for cold and dense two-color matter with two flavors of Wilson quarks. To achieve even qualitative agreement with lattice data requires the introduction of two novel elements in the model: (i) explicit chiral symmetry breaking in the effective contact four-fermion interaction, referred to as the chiral twist, and (ii) renormalization of the Polyakov loop. The feedback of the dense medium to the gauge sector is modeled by a chemical-potential-dependent scale in the Polyakov-loop potential. In contrast to previously used analytical Ansätze, we determine its dependence on the chemical potential from lattice data for the expectation value of the Polyakov loop. Finally, we propose adding a two-derivative operator to our effective model. This term acts as an additional source of explicit chiral symmetry breaking, mimicking an analogous term in the lattice Wilson action.
Probing deconfinement in a chiral effective model with Polyakov loop at imaginary chemical potential
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morita, Kenji; Yukawa Institute for Theoretical Physics, Kyoto University, Kyoto 606-8502; Skokov, Vladimir
2011-10-01
The phase structure of the two-flavor Polyakov-loop extended Nambu-Jona-Lashinio model is explored at finite temperature and imaginary chemical potential with a particular emphasis on the confinement-deconfinement transition. We point out that the confined phase is characterized by a cos3{mu}{sub I}/T dependence of the chiral condensate on the imaginary chemical potential while in the deconfined phase this dependence is given by cos{mu}{sub I}/T and accompanied by a cusp structure induced by the Z(3) transition. We demonstrate that the phase structure of the model strongly depends on the choice of the Polyakov loop potential U. Furthermore, we find that by changing themore » four fermion coupling constant G{sub s}, the location of the critical end point of the deconfinement transition can be moved into the real chemical potential region. We propose a new parameter characterizing the confinement-deconfinement transition.« less
Heavy quark free energy in QCD and in gauge theories with gravity duals
NASA Astrophysics Data System (ADS)
Noronha, Jorge
2010-09-01
Recent lattice results in pure glue SU(3) theory at high temperatures have shown that the expectation value of the renormalized Polyakov loop approaches its asymptotic limit at high temperatures from above. We show that this implies that the “heavy quark free energy” obtained from the renormalized loop computed on the lattice does not behave like a true thermodynamic free energy. While this should be expected to occur in asymptotically free gauge theories such as QCD, we use the gauge/string duality to show that in a large class of strongly coupled gauge theories with nontrivial UV fixed points the Polyakov loop reaches its asymptotic value from above only if the dimension of the relevant operator used to deform the conformal field theory is greater than or equal to 3.
Critical end point in the presence of a chiral chemical potential
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Z. -F.; Cloët, I. C.; Lu, Y.
A class of Polyakov-loop-modified Nambu-Jona-Lasinio models has been used to support a conjecture that numerical simulations of lattice-regularized QCD defined with a chiral chemical potential can provide information about the existence and location of a critical end point in the QCD phase diagram drawn in the plane spanned by baryon chemical potential and temperature. That conjecture is challenged by conflicts between the model results and analyses of the same problem using simulations of lattice-regularized QCD (lQCD) and well-constrained Dyson-Schwinger equation (DSE) studies. We find the conflict is resolved in favor of the lQCD and DSE predictions when both a physicallymore » motivated regularization is employed to suppress the contribution of high-momentum quark modes in the definition of the effective potential connected with the Polyakov-loop-modified Nambu-Jona-Lasinio models and the four-fermion coupling in those models does not react strongly to changes in the mean field that is assumed to mock-up Polyakov-loop dynamics. With the lQCD and DSE predictions thus confirmed, it seems unlikely that simulations of lQCD with mu(5) > 0 can shed any light on a critical end point in the regular QCD phase diagram.« less
ξ /ξ2 n d ratio as a tool to refine effective Polyakov loop models
NASA Astrophysics Data System (ADS)
Caselle, Michele; Nada, Alessandro
2017-10-01
Effective Polyakov line actions are a powerful tool to study the finite temperature behavior of lattice gauge theories. They are much simpler to simulate than the original lattice model and are affected by a milder sign problem, but it is not clear to which extent they really capture the rich spectrum of the original theories. We propose here a simple way to address this issue based on the so-called second moment correlation length ξ2 n d . The ratio ξ /ξ2 n d between the exponential correlation length and the second moment one is equal to 1 if only a single mass is present in the spectrum, and it becomes larger and larger as the complexity of the spectrum increases. Since both ξ and ξ2 n d are easy to measure on the lattice, this is a cheap and efficient way to keep track of the spectrum of the theory. As an example of the information one can obtain with this tool, we study the behavior of ξ /ξ2 n d in the confining phase of the (D =3 +1 ) SU(2) gauge theory and show that it is compatible with 1 near the deconfinement transition, but it increases dramatically as the temperature decreases. We also show that this increase can be well understood in the framework of an effective string description of the Polyakov loop correlator. This nontrivial behavior should be reproduced by the Polyakov loop effective action; thus, it represents a stringent and challenging test of existing proposals, and it may be used to fine-tune the couplings and to identify the range of validity of the approximations involved in their construction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krein, Gastao; Leme, Rafael R.; Woitek, Marcio
Traditional Monte Carlo simulations of QCD in the presence of a baryon chemical potential are plagued by the complex phase problem and new numerical approaches are necessary for studying the phase diagram of the theory. In this work we consider a Z{sub 3} Polyakov loop model for the deconfining phase transition in QCD and discuss how a flux representation of the model in terms of dimer and monomer variable solves the complex action problem. We present results of numerical simulations using a worm algorithm for the specific heat and two-point correlation function of Polyakov loops. Evidences of a first ordermore » deconfinement phase transition are discussed.« less
Dressed Wilson loops as dual condensates in response to magnetic and electric fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruckmann, Falk; Endroedi, Gergely
2011-10-01
We introduce dressed Wilson loops as a novel confinement observable. It consists of closed planar loops of arbitrary geometry but fixed area, and its expectation values decay with the latter. The construction of dressed Wilson loops is based on chiral condensates in response to magnetic and electric fields, thus linking different physical concepts. We present results for generalized condensates and dressed Wilson loops on dynamical lattice configurations and confirm the agreement with conventional Wilson loops in the limit of large probe mass. We comment on the renormalization of dressed Wilson loops.
Possible higher order phase transition in large-N gauge theory at finite temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishimura, Hiromichi
2017-08-07
We analyze the phase structure of SU(¥) gauge theory at finite temperature using matrix models. Our basic assumption is that the effective potential is dominated by double-trace terms for the Polyakov loops. As a function of the temperature, a background field for the Polyakov loop, and a quartic coupling, it exhibits a universal structure: in the large portion of the parameter space, there is a continuous phase transition analogous to the third-order phase transition of Gross,Witten and Wadia, but the order of phase transition can be higher than third. We show that different confining potentials give rise to drastically differentmore » behavior of the eigenvalue density and the free energy. Therefore lattice simulations at large N could probe the order of phase transition and test our results. Critical« less
The ξ/ξ2nd ratio as a test for Effective Polyakov Loop Actions
NASA Astrophysics Data System (ADS)
Caselle, Michele; Nada, Alessandro
2018-03-01
Effective Polyakov line actions are a powerful tool to study the finite temperature behaviour of lattice gauge theories. They are much simpler to simulate than the original (3+1) dimensional LGTs and are affected by a milder sign problem. However it is not clear to which extent they really capture the rich spectrum of the original theories, a feature which is instead of great importance if one aims to address the sign problem. We propose here a simple way to address this issue based on the so called second moment correlation length ξ2nd. The ratio ξ/ξ2nd between the exponential correlation length and the second moment one is equal to 1 if only a single mass is present in the spectrum, and becomes larger and larger as the complexity of the spectrum increases. Since both ξexp and ξ2nd are easy to measure on the lattice, this is an economic and effective way to keep track of the spectrum of the theory. In this respect we show using both numerical simulation and effective string calculations that this ratio increases dramatically as the temperature decreases. This non-trivial behaviour should be reproduced by the Polyakov loop effective action.
Finite-temperature phase transitions of third and higher order in gauge theories at large N
Nishimura, Hiromichi; Pisarski, Robert D.; Skokov, Vladimir V.
2018-02-15
We study phase transitions in SU(∞) gauge theories at nonzero temperature using matrix models. Our basic assumption is that the effective potential is dominated by double trace terms for the Polyakov loops. As a function of the various parameters, related to terms linear, quadratic, and quartic in the Polyakov loop, the phase diagram exhibits a universal structure. In a large region of this parameter space, there is a continuous phase transition whose order is larger than second. This is a generalization of the phase transition of Gross, Witten, and Wadia (GWW). Depending upon the detailed form of the matrix model,more » the eigenvalue density and the behavior of the specific heat near the transition differ drastically. Here, we speculate that in the pure gauge theory, that although the deconfining transition is thermodynamically of first order, it can be nevertheless conformally symmetric at infnite N.« less
Finite-temperature phase transitions of third and higher order in gauge theories at large N
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishimura, Hiromichi; Pisarski, Robert D.; Skokov, Vladimir V.
We study phase transitions in SU(∞) gauge theories at nonzero temperature using matrix models. Our basic assumption is that the effective potential is dominated by double trace terms for the Polyakov loops. As a function of the various parameters, related to terms linear, quadratic, and quartic in the Polyakov loop, the phase diagram exhibits a universal structure. In a large region of this parameter space, there is a continuous phase transition whose order is larger than second. This is a generalization of the phase transition of Gross, Witten, and Wadia (GWW). Depending upon the detailed form of the matrix model,more » the eigenvalue density and the behavior of the specific heat near the transition differ drastically. Here, we speculate that in the pure gauge theory, that although the deconfining transition is thermodynamically of first order, it can be nevertheless conformally symmetric at infnite N.« less
Polyakov loop and the hadron resonance gas model.
Megías, E; Arriola, E Ruiz; Salcedo, L L
2012-10-12
The Polyakov loop has been used repeatedly as an order parameter in the deconfinement phase transition in QCD. We argue that, in the confined phase, its expectation value can be represented in terms of hadronic states, similarly to the hadron resonance gas model for the pressure. Specifically, L(T)≈1/2[∑(α)g(α)e(-Δ(α)/T), where g(α) are the degeneracies and Δ(α) are the masses of hadrons with exactly one heavy quark (the mass of the heavy quark itself being subtracted). We show that this approximate sum rule gives a fair description of available lattice data with N(f)=2+1 for temperatures in the range 150 MeV
Nonperturbative quark-gluon thermodynamics at finite density
NASA Astrophysics Data System (ADS)
Andreichikov, M. A.; Lukashov, M. S.; Simonov, Yu. A.
2018-03-01
Thermodynamics of the quark-gluon plasma at finite density is studied in the framework of the Field Correlator Method, where thermodynamical effects of Polyakov loops and color magnetic confinement are taken into account. Having found good agreement with numerical lattice data for zero density, we calculate pressure P(T,μ), for 0 < μ < 400 MeV and 150 < T < 1000 MeV. For the first time, the explicit integral form is found in this region, demonstrating analytic structure in the complex μ plane. The resulting multiple complex branch points are found at the Roberge-Weiss values of Imμ, with Reμ defined by the values of Polyakov lines and color magnetic confinement.
Relating quark confinement and chiral symmetry breaking in QCD
NASA Astrophysics Data System (ADS)
Suganuma, Hideo; Doi, Takahiro M.; Redlich, Krzysztof; Sasaki, Chihiro
2017-12-01
We study the relation between quark confinement and chiral symmetry breaking in QCD. Using lattice QCD formalism, we analytically express the various ‘confinement indicators’, such as the Polyakov loop, its fluctuations, the Wilson loop, the inter-quark potential and the string tension, in terms of the Dirac eigenmodes. In the Dirac spectral representation, there appears a power of the Dirac eigenvalue {λ }n such as {λ }n{Nt-1}, which behaves as a reduction factor for small {λ }n. Consequently, since this reduction factor cannot be cancelled, the low-lying Dirac eigenmodes give negligibly small contribution to the confinement quantities, while they are essential for chiral symmetry breaking. These relations indicate that there is no direct one-to-one correspondence between confinement and chiral symmetry breaking in QCD. In other words, there is some independence of quark confinement from chiral symmetry breaking, which can generally lead to different transition temperatures/densities for deconfinement and chiral restoration. We also investigate the Polyakov loop in terms of the eigenmodes of the Wilson, the clover and the domain-wall fermion kernels, and find similar results. The independence of quark confinement from chiral symmetry breaking seems to be natural, because confinement is realized independently of quark masses and heavy quarks are also confined even without the chiral symmetry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Contrera, G. A.; CONICET, Rivadavia 1917, 1033 Buenos Aires; Dumm, D. Gomez
2010-03-01
We study the finite temperature behavior of light scalar and pseudoscalar meson properties in the context of a three-flavor nonlocal chiral quark model. The model includes mixing with active strangeness degrees of freedom, and takes care of the effect of gauge interactions by coupling the quarks with the Polyakov loop. We analyze the chiral restoration and deconfinement transitions, as well as the temperature dependence of meson masses, mixing angles and decay constants. The critical temperature is found to be T{sub c{approx_equal}}202 MeV, in better agreement with lattice results than the value recently obtained in the local SU(3) PNJL model. Itmore » is seen that above T{sub c} pseudoscalar meson masses get increased, becoming degenerate with the masses of their chiral partners. The temperatures at which this matching occurs depend on the strange quark composition of the corresponding mesons. The topological susceptibility shows a sharp decrease after the chiral transition, signalling the vanishing of the U(1){sub A} anomaly for large temperatures.« less
Effective model approach to the dense state of QCD matter
NASA Astrophysics Data System (ADS)
Fukushima, Kenji
2011-12-01
The first-principle approach to the dense state of QCD matter, i.e. the lattice-QCD simulation at finite baryon density, is not under theoretical control for the moment. The effective model study based on QCD symmetries is a practical alternative. However the model parameters that are fixed by hadronic properties in the vacuum may have unknown dependence on the baryon chemical potential. We propose a new prescription to constrain the effective model parameters by the matching condition with the thermal Statistical Model. In the transitional region where thermal quantities blow up in the Statistical Model, deconfined quarks and gluons should smoothly take over the relevant degrees of freedom from hadrons and resonances. We use the Polyakov-loop coupled Nambu-Jona-Lasinio (PNJL) model as an effective description in the quark side and show how the matching condition is satisfied by a simple ansäatz on the Polyakov loop potential. Our results favor a phase diagram with the chiral phase transition located at slightly higher temperature than deconfinement which stays close to the chemical freeze-out points.
Effects of Composite Pions on the Chiral Condensate within the PNJL Model at Finite Temperature
NASA Astrophysics Data System (ADS)
Blaschke, D.; Dubinin, A.; Ebert, D.; Friesen, A. V.
2018-05-01
We investigate the effect of composite pions on the behaviour of the chiral condensate at finite temperature within the Polyakov-loop improved NJL model. To this end we treat quark-antiquark correlations in the pion channel (bound states and scattering continuum) within a Beth-Uhlenbeck approach that uses medium-dependent phase shifts. A striking medium effect is the Mott transition which occurs when the binding energy vanishes and the discrete pion bound state merges the continuum. This transition is triggered by the lowering of the continuum edge due to the chiral restoration transition. This in turn also entails a modification of the Polyakov-loop so that the SU(3) center symmetry gets broken at finite temperature and dynamical quarks (and gluons) appear in the system, taking over the role of the dominant degrees of freedom from the pions. At low temperatures our model reproduces the chiral perturbation theory result for the chiral condensate while at high temperatures the PNJL model result is recovered. The new aspect of the current work is a consistent treatment of the chiral restoration transition region within the Beth-Uhlenbeck approach on the basis of mesonic phase shifts for the treatment of the correlations.
Free energy and phase transition of the matrix model on a plane wave
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadizadeh, Shirin; Ramadanovic, Bojan; Semenoff, Gordon W.
2005-03-15
It has recently been observed that the weakly coupled plane-wave matrix model has a density of states which grows exponentially at high energy. This implies that the model has a phase transition. The transition appears to be of first order. However, its exact nature is sensitive to interactions. In this paper, we analyze the effect of interactions by computing the relevant parts of the effective potential for the Polyakov loop operator in the finite temperature plane-wave matrix model to three-loop order. We show that the phase transition is indeed of first order. We also compute the correction to the Hagedornmore » temperature to order two loops.« less
NASA Astrophysics Data System (ADS)
Silva, P. J.; Oliveira, O.
2016-06-01
The correlations between the modulus of the Polyakov loop, its phase θ , and the Landau gauge gluon propagator at finite temperature are investigated in connection with the center symmetry for pure Yang-Mills SU(3) theory. In the deconfined phase, where the center symmetry is spontaneously broken, the phase of the Polyakov loop per configuration is close to θ =0 , ±2 π /3 . We find that the gluon propagator form factors associated with θ ≈0 differ quantitatively and qualitatively from those associated to θ ≈±2 π /3 . This difference between the form factors is a property of the deconfined phase and a sign of the spontaneous breaking of the center symmetry. Furthermore, given that this difference vanishes in the confined phase, it can be used as an order parameter associated to the deconfinement transition. For simulations near the critical temperature Tc, the difference between the propagators associated to θ ≈0 and θ ≈±2 π /3 allows one to classify the configurations as belonging to the confined or deconfined phase. This establishes a selection procedure which has a measurable impact on the gluon form factors. Our results also show that the absence of the selection procedure can be erroneously interpreted as lattice artifacts.
Strings with a confining core in a quark-gluon plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Layek, Biswanath; Mishra, Ananta P.; Srivastava, Ajit M.
2005-04-01
We consider the intersection of N different interfaces interpolating between different Z{sub N} vacua of an SU(N) gauge theory using the Polyakov loop order parameter. Topological arguments show that at such a stringlike junction, the order parameter should vanish, implying that the core of this string (i.e. the junction region of all the interfaces) is in the confining phase. Using the effective potential for the Polyakov loop proposed by Pisarski for QCD, we use numerical minimization technique and estimate the energy per unit length of the core of this string to be about 2.7 GeV/fm at a temperature about twicemore » the critical temperature. For the parameters used, the interface tension is obtained to be about 7 GeV/fm{sup 2}. Lattice simulation of pure gauge theories should be able to investigate properties of these strings. For QCD with quarks, it has been discussed in the literature that this Z{sub N} symmetry may still be meaningful, with quark contributions leading to explicit breaking of this Z{sub N} symmetry. With this interpretation, such quark-gluon plasma strings may play important role in the evolution of the quark-gluon plasma phase and in the dynamics of quark-hadron transition.« less
QCD phase diagram using PNJL model with eight-quark interactions
NASA Astrophysics Data System (ADS)
Deb, Paramita; Bhattacharyya, Abhijit; Ghosh, Sanjay K.; Ray, Rajarshi; Lahiri, Anirban
2011-07-01
We present the phase diagram and the fluctuations of different conserved charges like quark number, charge and strangeness at vanishing chemical potential for the 2+1 flavor Polyakov Loop extended Nambu-Jona-Lasinio model with eight-quark interaction terms using three-momentum cutoff regularisation. The main effect of the higher order interaction term is to shift the critical end point to the lower value of the chemical potential and higher value of the temperature. The fluctuations show good qualitative agreement with the lattice data.
Simulation of Z(3) walls and string production via bubble nucleation in a quark-hadron transition
NASA Astrophysics Data System (ADS)
Gupta, Uma Shankar; Mohapatra, Ranjita K.; Srivastava, Ajit M.; Tiwari, Vivek K.
2010-10-01
We study the dynamics of confinement-deconfinement phase transition in the context of relativistic heavy-ion collisions within the framework of effective models for the Polyakov loop order parameter. We study the formation of Z(3) walls and associated strings in the initial transition from the confining (hadronic) phase to the deconfining [quark-gluon plasma (QGP)] phase via the so-called Kibble mechanism. Essential physics of the Kibble mechanism is contained in a sort of domain structure arising after any phase transition which represents random variation of the order parameter at distances beyond the typical correlation length. We implement this domain structure by using the Polyakov loop effective model with a first order phase transition and confine ourselves with temperature/time ranges so that the first order confinement-deconfinement transition proceeds via bubble nucleation, leading to a well defined domain structure. The formation of Z(3) walls and associated strings results from the coalescence of QGP bubbles expanding in the confining background. We investigate the evolution of the Z(3) wall and string network. We also calculate the energy density fluctuations associated with Z(3) wall network and strings which decay away after the temperature drops below the quark-hadron transition temperature during the expansion of QGP. We discuss evolution of these quantities with changing temperature via Bjorken’s hydrodynamical model and discuss possible experimental signatures resulting from the presence of Z(3) wall network and associate strings.
Simulation of Z(3) walls and string production via bubble nucleation in a quark-hadron transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, Uma Shankar; Tiwari, Vivek K.; Mohapatra, Ranjita K.
2010-10-01
We study the dynamics of confinement-deconfinement phase transition in the context of relativistic heavy-ion collisions within the framework of effective models for the Polyakov loop order parameter. We study the formation of Z(3) walls and associated strings in the initial transition from the confining (hadronic) phase to the deconfining [quark-gluon plasma (QGP)] phase via the so-called Kibble mechanism. Essential physics of the Kibble mechanism is contained in a sort of domain structure arising after any phase transition which represents random variation of the order parameter at distances beyond the typical correlation length. We implement this domain structure by using themore » Polyakov loop effective model with a first order phase transition and confine ourselves with temperature/time ranges so that the first order confinement-deconfinement transition proceeds via bubble nucleation, leading to a well defined domain structure. The formation of Z(3) walls and associated strings results from the coalescence of QGP bubbles expanding in the confining background. We investigate the evolution of the Z(3) wall and string network. We also calculate the energy density fluctuations associated with Z(3) wall network and strings which decay away after the temperature drops below the quark-hadron transition temperature during the expansion of QGP. We discuss evolution of these quantities with changing temperature via Bjorken's hydrodynamical model and discuss possible experimental signatures resulting from the presence of Z(3) wall network and associate strings.« less
NASA Astrophysics Data System (ADS)
Maelger, J.; Reinosa, U.; Serreau, J.
2018-04-01
We extend a previous investigation [U. Reinosa et al., Phys. Rev. D 92, 025021 (2015), 10.1103/PhysRevD.92.025021] of the QCD phase diagram with heavy quarks in the context of background field methods by including the two-loop corrections to the background field effective potential. The nonperturbative dynamics in the pure-gauge sector is modeled by a phenomenological gluon mass term in the Landau-DeWitt gauge-fixed action, which results in an improved perturbative expansion. We investigate the phase diagram at nonzero temperature and (real or imaginary) chemical potential. Two-loop corrections yield an improved agreement with lattice data as compared to the leading-order results. We also compare with the results of nonperturbative continuum approaches. We further study the equation of state as well as the thermodynamic stability of the system at two-loop order. Finally, using simple thermodynamic arguments, we show that the behavior of the Polyakov loops as functions of the chemical potential complies with their interpretation in terms of quark and antiquark free energies.
NASA Astrophysics Data System (ADS)
Elizaga Navascués, Beatriz; Martín de Blas, Daniel; Mena Marugán, Guillermo A.
2018-02-01
Loop quantum cosmology has recently been applied in order to extend the analysis of primordial perturbations to the Planck era and discuss the possible effects of quantum geometry on the cosmic microwave background. Two approaches to loop quantum cosmology with admissible ultraviolet behavior leading to predictions that are compatible with observations are the so-called hybrid and dressed metric approaches. In spite of their similarities and relations, we show in this work that the effective equations that they provide for the evolution of the tensor and scalar perturbations are somewhat different. When backreaction is neglected, the discrepancy appears only in the time-dependent mass term of the corresponding field equations. We explain the origin of this difference, arising from the distinct quantization procedures. Besides, given the privileged role that the big bounce plays in loop quantum cosmology, e.g. as a natural instant of time to set initial conditions for the perturbations, we also analyze the positivity of the time-dependent mass when this bounce occurs. We prove that the mass of the tensor perturbations is positive in the hybrid approach when the kinetic contribution to the energy density of the inflaton dominates over its potential, as well as for a considerably large sector of backgrounds around that situation, while this mass is always nonpositive in the dressed metric approach. Similar results are demonstrated for the scalar perturbations in a sector of background solutions that includes the kinetically dominated ones; namely, the mass then is positive for the hybrid approach, whereas it typically becomes negative in the dressed metric case. More precisely, this last statement is strictly valid when the potential is quadratic for values of the inflaton mass that are phenomenologically favored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pisarski, Robert D.; Skokov, Vladimir V.
Previously, a matrix model of the region near the transition temperature, in the “semi”quark gluon plasma, was developed for the theory of SU(3) gluons without quarks. In this paper we develop a chiral matrix model applicable to QCD by including dynamical quarks with 2+1 flavors. This requires adding a nonet of scalar fields, with both parities, and coupling these to quarks through a Yukawa coupling, y. Treating the scalar fields in mean field approximation, the effective Lagrangian is computed by integrating out quarks to one loop order. As is standard, the potential for the scalar fields is chosen to bemore » symmetric under the flavor symmetry of SU (3) L × SU(3) R × Z (3) A , except for a term linear in the current quark mass, m qk . In addition, at a nonzero temperature T it is necessary to add a new term, ~ m qk T 2 . The parameters of the gluon part of the matrix model are identical to those for the pure glue theory without quarks. The parameters in the chiral matrix model are fixed by the values, at zero temperature, of the pion decay constant and the masses of the pions, kaons, η , and η' . The temperature for the chiral crossover at T$χ$ = 155 MeV is determined by adjusting the Yukawa coupling y . We find reasonable agreement with the results of numerical simulations on the lattice for the pressure and related quantities. In the chiral limit, besides the divergence in the chiral susceptibility there is also a milder divergence in the susceptibility between the Polyakov loop and the chiral order parameter, with critical exponent β $-$ 1 . We compute derivatives with respect to a quark chemical potential to determine the susceptibilities for baryon number, the $χ$ 2n . Especially sensitive tests are provided by $χ$ 4 $-$ $χ$ 2 and by $χ$ 6 , which changes in sign about T$χ$ . In conclusion, the behavior of the susceptibilities in the chiral matrix model strongly suggests that as the temperature increases from T$χ$ , that the transition to deconfinement is significantly quicker than indicated by the measurements of the (renormalized) Polyakov loop on the lattice.« less
Chiral matrix model of the semi-QGP in QCD
Pisarski, Robert D.; Skokov, Vladimir V.
2016-08-08
Previously, a matrix model of the region near the transition temperature, in the “semi”quark gluon plasma, was developed for the theory of SU(3) gluons without quarks. In this paper we develop a chiral matrix model applicable to QCD by including dynamical quarks with 2+1 flavors. This requires adding a nonet of scalar fields, with both parities, and coupling these to quarks through a Yukawa coupling, y. Treating the scalar fields in mean field approximation, the effective Lagrangian is computed by integrating out quarks to one loop order. As is standard, the potential for the scalar fields is chosen to bemore » symmetric under the flavor symmetry of SU (3) L × SU(3) R × Z (3) A , except for a term linear in the current quark mass, m qk . In addition, at a nonzero temperature T it is necessary to add a new term, ~ m qk T 2 . The parameters of the gluon part of the matrix model are identical to those for the pure glue theory without quarks. The parameters in the chiral matrix model are fixed by the values, at zero temperature, of the pion decay constant and the masses of the pions, kaons, η , and η' . The temperature for the chiral crossover at T$χ$ = 155 MeV is determined by adjusting the Yukawa coupling y . We find reasonable agreement with the results of numerical simulations on the lattice for the pressure and related quantities. In the chiral limit, besides the divergence in the chiral susceptibility there is also a milder divergence in the susceptibility between the Polyakov loop and the chiral order parameter, with critical exponent β $-$ 1 . We compute derivatives with respect to a quark chemical potential to determine the susceptibilities for baryon number, the $χ$ 2n . Especially sensitive tests are provided by $χ$ 4 $-$ $χ$ 2 and by $χ$ 6 , which changes in sign about T$χ$ . In conclusion, the behavior of the susceptibilities in the chiral matrix model strongly suggests that as the temperature increases from T$χ$ , that the transition to deconfinement is significantly quicker than indicated by the measurements of the (renormalized) Polyakov loop on the lattice.« less
Dressing the post-Newtonian two-body problem and classical effective field theory
NASA Astrophysics Data System (ADS)
Kol, Barak; Smolkin, Michael
2009-12-01
We apply a dressed perturbation theory to better organize and economize the computation of high orders of the 2-body effective action of an inspiralling post-Newtonian (PN) gravitating binary. We use the effective field theory approach with the nonrelativistic field decomposition (NRG fields). For that purpose we develop quite generally the dressing theory of a nonlinear classical field theory coupled to pointlike sources. We introduce dressed charges and propagators, but unlike the quantum theory there are no dressed bulk vertices. The dressed quantities are found to obey recursive integral equations which succinctly encode parts of the diagrammatic expansion, and are the classical version of the Schwinger-Dyson equations. Actually, the classical equations are somewhat stronger since they involve only finitely many quantities, unlike the quantum theory. Classical diagrams are shown to factorize exactly when they contain nonlinear worldline vertices, and we classify all the possible topologies of irreducible diagrams for low loop numbers. We apply the dressing program to our post-Newtonian case of interest. The dressed charges consist of the dressed energy-momentum tensor after a nonrelativistic decomposition, and we compute all dressed charges (in the harmonic gauge) appearing up to 2PN in the 2-body effective action (and more). We determine the irreducible skeleton diagrams up to 3PN and we employ the dressed charges to compute several terms beyond 2PN.
Flux tubes in the SU(3) vacuum: London penetration depth and coherence length
NASA Astrophysics Data System (ADS)
Cea, Paolo; Cosmai, Leonardo; Cuteri, Francesca; Papa, Alessandro
2014-05-01
Within the dual superconductor scenario for the QCD confining vacuum, the chromoelectric field generated by a static qq¯ pair can be fitted by a function derived, by dual analogy, from a simple variational model for the magnitude of the normalized order parameter of an isolated Abrikosov vortex. Previous results for the SU(3) vacuum are revisited, but here the transverse chromoelectric field is measured by means of the connected correlator of two Polyakov loops and, in order to reduce noise, the smearing procedure is used instead of cooling. The penetration and coherence lengths of the flux tube are then extracted from the fit and compared with previous results.
Crozer-Chester Medical Center Burn Research Projects
2009-07-01
Dressing for Autogenous Skin Donor Sites” This study will compare the performance of an agreed upon dressing to the normal standard of care (Xeroform...resuscitation algorithm for the development of a closed loop resuscitation system. a. Complete project start-up activities (hiring and training of...collect data (Year 2, Quarter 1) Study 2, Protocol Title: “Evaluation of Xxx for Autogenous Skin Donor Sites” Task 1: Enroll up to 30 patients in
The AdS/CFT Correspondence: Classical, Quantum, and Thermodynamical Aspects
NASA Astrophysics Data System (ADS)
Young, Donovan
2007-06-01
Certain aspects of the AdS/CFT correspondence are studied in detail. We investigate the one-loop mass shift to certain two-impurity string states in light-cone string field theory on a plane wave background. We find that there exist logarithmic divergences in the sums over intermediate mode numbers which cancel between the cubic Hamiltonian and quartic "contact term". We argue that generically, every order in intermediate state impurities contributes to the mass shift at leading perturbative order. The same mass shift is also computed using an improved 3-string vertex proposed by Dobashi and Yoneya. The result is found to agree with gauge theory at leading order and is close but not quite in agreement at subleading order. We extend the analysis to include discrete light-cone quantization, considering states with up to three units of p+. We study the (apparently) first-order phase transition in the weakly coupled plane-wave matrix model at finite temperature. We analyze the effect of interactions by computing the relevant parts of the effective potential for the Polyakov loop operator to three loop order. We show that the phase transition is indeed of first order. We also compute the 2-loop correction to the Hagedorn temperature. Finally, correlation functions of 1/4 BPS Wilson loops with the infinite family of 1/2 BPS chiral primary operators are computed in N=4 super Yang-Mills theory by summing planar ladder diagrams. The correlation functions are also computed in the strong-coupling limit using string theory; the result is found to agree with the extrapolation of the planar ladders. The result is related to similar correlators of 1/2 BPS loops by a simple re-scaling of the coupling constant, discovered by Drukker for the case of the 1/4 BPS loop VEV.
NASA Astrophysics Data System (ADS)
Murugan, Jeff; Weltman, Amanda; Ellis, George F. R.
2012-07-01
1. The problem with quantum gravity Jeff Murugan, Amanda Weltman and George F. R. Eliis; 2. A dialogue on the nature of gravity Thanu Padmanabhan; 3. Effective theories and modifications of gravity Cliff Burgess; 4. The small scale structure of spacetime Steve Carlip; 5. Ultraviolet divergences in supersymmetric theories Kellog Stelle; 6. Cosmological quantum billiards Axel Kleinschmidt and Hermann Nicolai; 7. Progress in RNS string theory and pure spinors Dimitri Polyakov; 8. Recent trends in superstring phenomenology Massimo Bianchi; 9. Emergent spacetime Robert de Mello Koch and Jeff Murugan; 10. Loop quantum gravity Hanno Sahlmann; 11. Loop quantum gravity and cosmology Martin Bojowald; 12. The microscopic dynamics of quantum space as a group field theory Daniele Oriti; 13. Causal dynamical triangulations and the quest for quantum gravity Jan Ambjørn, J. Jurkiewicz and Renate Loll; 14. Proper time is stochastic time in 2D quantum gravity Jan Ambjorn, Renate Loll, Y. Watabiki, W. Westra and S. Zohren; 15. Logic is to the quantum as geometry is to gravity Rafael Sorkin; 16. Causal sets: discreteness without symmetry breaking Joe Henson; 17. The Big Bang, quantum gravity, and black-hole information loss Roger Penrose; Index.
Hydrodynamics of the Polyakov line in SU(N c) Yang-Mills
Liu, Yizhuang; Warchoł, Piotr; Zahed, Ismail
2015-12-08
We discuss a hydrodynamical description of the eigenvalues of the Polyakov line at large but finite N c for Yang-Mills theory in even and odd space-time dimensions. The hydro-static solutions for the eigenvalue densities are shown to interpolate between a uniform distribution in the confined phase and a localized distribution in the de-confined phase. The resulting critical temperatures are in overall agreement with those measured on the lattice over a broad range of N c, and are consistent with the string model results at N c = ∞. The stochastic relaxation of the eigenvalues of the Polyakov line out ofmore » equilibrium is captured by a hydrodynamical instanton. An estimate of the probability of formation of a Z(N c)bubble using a piece-wise sound wave is suggested.« less
SU (2) lattice gauge theory simulations on Fermi GPUs
NASA Astrophysics Data System (ADS)
Cardoso, Nuno; Bicudo, Pedro
2011-05-01
In this work we explore the performance of CUDA in quenched lattice SU (2) simulations. CUDA, NVIDIA Compute Unified Device Architecture, is a hardware and software architecture developed by NVIDIA for computing on the GPU. We present an analysis and performance comparison between the GPU and CPU in single and double precision. Analyses with multiple GPUs and two different architectures (G200 and Fermi architectures) are also presented. In order to obtain a high performance, the code must be optimized for the GPU architecture, i.e., an implementation that exploits the memory hierarchy of the CUDA programming model. We produce codes for the Monte Carlo generation of SU (2) lattice gauge configurations, for the mean plaquette, for the Polyakov Loop at finite T and for the Wilson loop. We also present results for the potential using many configurations (50,000) without smearing and almost 2000 configurations with APE smearing. With two Fermi GPUs we have achieved an excellent performance of 200× the speed over one CPU, in single precision, around 110 Gflops/s. We also find that, using the Fermi architecture, double precision computations for the static quark-antiquark potential are not much slower (less than 2× slower) than single precision computations.
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
2016-11-15
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennington, M. R.; Wilson, D. J.
2011-11-01
The gluon and ghost propagators in Landau gauge QCD are investigated using the Schwinger-Dyson equation approach. Working in Euclidean spacetime, we solve for these propagators using a selection of vertex inputs, initially for the ghost equation alone and then for both propagators simultaneously. The results are shown to be highly sensitive to the choices of vertices. We favor the infrared finite ghost solution from studying the ghost equation alone where we argue for a specific unique solution. In order to solve this simultaneously with the gluon using a dressed-one-loop truncation, we find that a nontrivial full ghost-gluon vertex is requiredmore » in the vanishing gluon momentum limit. The self-consistent solutions we obtain correspond to having a masslike term in the gluon propagator dressing, in agreement with similar studies supporting the long-held proposal of Cornwall.« less
Lorentz-violating SO(3) model: Discussing unitarity, causality, and 't Hooft-Polyakov monopoles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarpelli, A.P. Baeta; Grupo de Fisica Teorica Jose Leite Lopes, Petropolis, RJ; Helayeel-Neto, J.A.
2006-05-15
In this paper, we extend the analysis of the Lorentz-violating Quantum Electrodynamics to the non-Abelian case: an SO(3) Yang-Mills Lagrangian with the addition of the non-Abelian Chern-Simons-type term. We consider the spontaneous symmetry breaking of the model and inspect its spectrum in order to check if unitarity and causality are respected. An analysis of the topological structure is also carried out and we show that a 't Hooft-Polyakov solution for monopoles is still present.
Gauge copies in the Landau-DeWitt gauge: A background invariant restriction
NASA Astrophysics Data System (ADS)
Dudal, David; Vercauteren, David
2018-04-01
The Landau background gauge, also known as the Landau-DeWitt gauge, has found renewed interest during the past decade given its usefulness in accessing the confinement-deconfinement transition via the vacuum expectation value of the Polyakov loop, describable via an appropriate background. In this Letter, we revisit this gauge from the viewpoint of it displaying gauge (Gribov) copies. We generalize the Gribov-Zwanziger effective action in a BRST and background invariant way; this action leads to a restriction on the allowed gauge fluctuations, thereby eliminating the infinitesimal background gauge copies. The explicit background invariance of our action is in contrast with earlier attempts to write down and use an effective Gribov-Zwanziger action. It allows to address certain subtleties arising in these earlier works, such as a spontaneous and thus spurious Lorentz symmetry breaking, something which is now averted.
SU (2) lattice gauge theory simulations on Fermi GPUs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardoso, Nuno, E-mail: nunocardoso@cftp.ist.utl.p; Bicudo, Pedro, E-mail: bicudo@ist.utl.p
2011-05-10
In this work we explore the performance of CUDA in quenched lattice SU (2) simulations. CUDA, NVIDIA Compute Unified Device Architecture, is a hardware and software architecture developed by NVIDIA for computing on the GPU. We present an analysis and performance comparison between the GPU and CPU in single and double precision. Analyses with multiple GPUs and two different architectures (G200 and Fermi architectures) are also presented. In order to obtain a high performance, the code must be optimized for the GPU architecture, i.e., an implementation that exploits the memory hierarchy of the CUDA programming model. We produce codes formore » the Monte Carlo generation of SU (2) lattice gauge configurations, for the mean plaquette, for the Polyakov Loop at finite T and for the Wilson loop. We also present results for the potential using many configurations (50,000) without smearing and almost 2000 configurations with APE smearing. With two Fermi GPUs we have achieved an excellent performance of 200x the speed over one CPU, in single precision, around 110 Gflops/s. We also find that, using the Fermi architecture, double precision computations for the static quark-antiquark potential are not much slower (less than 2x slower) than single precision computations.« less
Baryon inhomogeneity generation in the quark-gluon plasma phase
DOE Office of Scientific and Technical Information (OSTI.GOV)
Layek, Biswanath; Mishra, Ananta P.; Srivastava, Ajit M.
2006-05-15
We discuss the possibility of generation of baryon inhomogeneities in a quark-gluon plasma phase due to moving Z(3) interfaces. By modeling the dependence of effective mass of the quarks on the Polyakov loop order parameter, we study the reflection of quarks from collapsing Z(3) interfaces and estimate resulting baryon inhomogeneities in the context of the early universe. We argue that in the context of certain low energy scale inflationary models, it is possible that large Z(3) walls arise at the end of the reheating stage. Collapse of such walls could lead to baryon inhomogeneities which may be separated by largemore » distances near the QCD scale. Importantly, the generation of these inhomogeneities is insensitive to the order, or even the existence, of the quark-hadron phase transition. We also briefly discuss the possibility of formation of quark nuggets in this model, as well as baryon inhomogeneity generation in relativistic heavy-ion collisions.« less
NASA Astrophysics Data System (ADS)
Tomiya, Akio; Ding, Heng-Tong; Mukherjee, Swagato; Schmidt, Christian; Wang, Xiao-Dan
2018-03-01
Lattice simulations for (2+1)-flavor QCD with external magnetic field demon-strated that the quark mass is one of the important parameters responsible for the (inverse) magnetic catalysis. We discuss the dependences of chiral condensates and susceptibilities, the Polyakov loop on the magnetic field and quark mass in three degenerate flavor QCD. The lattice simulations are performed using standard staggered fermions and the plaquette action with spatial sizes Nσ = 16 and 24 and a fixed temporal size Nτ = 4. The value of the quark masses are chosen such that the system undergoes a first order chiral phase transition and crossover with zero magnetic field. We find that in light mass regime, the quark chiral condensate undergoes magnetic catalysis in the whole temperature region and the phase transition tend to become stronger as the magnetic field increases. In crossover regime, deconfinement transition temperature is shifted by the magnetic field when quark mass ma is less than 0:4. The lattice cutoff effects are also discussed.
NASA Astrophysics Data System (ADS)
Andreoli, Michele; Bonati, Claudio; D'Elia, Massimo; Mesiti, Michele; Negro, Francesco; Rucci, Andrea; Sanfilippo, Francesco
2018-03-01
We discuss the extension of gauge-invariant electric and magnetic screening masses in the quark-gluon plasma to the case of a finite baryon density, defining them in terms of a matrix of Polyakov loop correlators. We present lattice results for Nf=2 +1 QCD with physical quark masses, obtained using the imaginary chemical potential approach, which indicate that the screening masses increase as a function of μB. A separate analysis is carried out for the theoretically interesting case μB/T =3 i π , where charge conjugation is not explicitly broken and the usual definition of the screening masses can be used for temperatures below the Roberge-Weiss transition. Finally, we investigate the dependence of the static quark free energy on the baryon chemical potential, showing that it is a decreasing function of μB, which displays a peculiar behavior as the pseudocritical transition temperature at μB=0 is approached.
Moving heavy quarkonium entropy, effective string tension, and the QCD phase diagram
NASA Astrophysics Data System (ADS)
Chen, Xun; Feng, Sheng-Qin; Shi, Ya-Fei; Zhong, Yang
2018-03-01
The entropy and effective string tension of the moving heavy quark-antiquark pair in the strongly coupled plasmas are calculated by using a deformed an anti-de Sitter/Reissner-Nordström black hole metric. A sharp peak of the heavy-quarkonium entropy around the deconfinement transition can be realized in our model, which is consistent with the lattice QCD result. The effective string tension of the heavy quark-antiquark pair is related to the deconfinement phase transition. Thus, we investigate the deconfinement phase transition by analyzing the characteristics of the effective string tension with different temperatures, chemical potentials, and rapidities. It is found that the results of phase diagram calculated through effective string tension are in agreement with results calculated through a Polyakov loop. We argue that a moving system will reach the phase transition point at a lower temperature and chemical potential than a stationary system. It means that the lifetime of the moving quark-gluon plasma become longer than the static one.
Bethe Ansatz solutions for highest states in Script N = 4 SYM and AdS/CFT duality
NASA Astrophysics Data System (ADS)
Beccaria, Matteo; DelDebbio, Luigi
2006-09-01
We consider the operators with highest anomalous dimension Δ in the compact rank-one sectors fraktur sfraktur u(1|1) and fraktur sfraktur u(2) of Script N = 4 super Yang-Mills. We study the flow of Δ from weak to strong 't Hooft coupling λ by solving (i) the all-loop gauge Bethe Ansatz, (ii) the quantum string Bethe Ansatz. The two calculations are carefully compared in the strong coupling limit and exhibit different exponents ν in the leading order expansion Δ ~ λν. We find ν = 1/2 and ν = 1/4 for the gauge or string solution. This strong coupling discrepancy is not unexpected, and it provides an explicit example where the gauge Bethe Ansatz solution cannot be trusted at large λ. Instead, the string solution perfectly reproduces the Gubser-Klebanov-Polyakov law Δ = 2n1/2 λ1/4. In particular, we provide an analytic expression for the integer level n as a function of the U(1) charge in both sectors.
Gravitational form factors and decoupling in 2D
NASA Astrophysics Data System (ADS)
Ribeiro, Tiago G.; Shapiro, Ilya L.; Zanusso, Omar
2018-07-01
We calculate and analyse non-local gravitational form factors induced by quantum matter fields in curved two-dimensional space. The calculations are performed for scalars, spinors and massive vectors by means of the covariant heat kernel method up to the second order in the curvature and confirmed using Feynman diagrams. The analysis of the ultraviolet (UV) limit reveals a generalized "running" form of the Polyakov action for a nonminimal scalar field and the usual Polyakov action in the conformally invariant cases. In the infrared (IR) we establish the gravitational decoupling theorem, which can be seen directly from the form factors or from the physical beta function for fields of any spin.
Topological and trivial magnetic oscillations in nodal loop semimetals
NASA Astrophysics Data System (ADS)
Oroszlány, László; Dóra, Balázs; Cserti, József; Cortijo, Alberto
2018-05-01
Nodal loop semimetals are close descendants of Weyl semimetals and possess a topologically dressed band structure. We argue by combining the conventional theory of magnetic oscillation with topological arguments that nodal loop semimetals host coexisting topological and trivial magnetic oscillations. These originate from mapping the topological properties of the extremal Fermi surface cross sections onto the physics of two dimensional semi-Dirac systems, stemming from merging two massless Dirac cones. By tuning the chemical potential and the direction of magnetic field, a sharp transition is identified from purely trivial oscillations, arising from the Landau levels of a normal two dimensional (2D) electron gas, to a phase where oscillations of topological and trivial origin coexist, originating from 2D massless Dirac and semi-Dirac points, respectively. These could in principle be directly identified in current experiments.
Symmetry preserving truncations of the gap and Bethe-Salpeter equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binosi, Daniele; Chang, Lei; Papavassiliou, Joannis
2016-05-01
Ward-Green-Takahashi (WGT) identities play a crucial role in hadron physics, e.g. imposing stringent relationships between the kernels of the one-and two-body problems, which must be preserved in any veracious treatment of mesons as bound states. In this connection, one may view the dressed gluon-quark vertex, Gamma(alpha)(mu), as fundamental. We use a novel representation of Gamma(alpha)(mu), in terms of the gluon-quark scattering matrix, to develop a method capable of elucidating the unique quark-antiquark Bethe-Salpeter kernel, K, that is symmetry consistent with a given quark gap equation. A strength of the scheme is its ability to expose and capitalize on graphic symmetriesmore » within the kernels. This is displayed in an analysis that reveals the origin of H-diagrams in K, which are two-particle-irreducible contributions, generated as two-loop diagrams involving the three-gluon vertex, that cannot be absorbed as a dressing of Gamma(alpha)(mu) in a Bethe-Salpeter kernel nor expressed as a member of the class of crossed-box diagrams. Thus, there are no general circumstances under which the WGT identities essential for a valid description of mesons can be preserved by a Bethe-Salpeter kernel obtained simply by dressing both gluon-quark vertices in a ladderlike truncation; and, moreover, adding any number of similarly dressed crossed-box diagrams cannot improve the situation.« less
Worldsheet scattering in AdS3/CFT2
NASA Astrophysics Data System (ADS)
Sundin, Per; Wulff, Linus
2013-07-01
We confront the recently proposed exact S-matrices for AdS 3/ CFT 2 with direct worldsheet calculations. Utilizing the BMN and Near Flat Space (NFS) expansions for strings on AdS 3 × S 3 × S 3 × S 1 and AdS 3 × S 3 × T 4 we compute both tree-level and one-loop scattering amplitudes. Up to some minor issues we find nice agreement in the tree-level sector. At the one-loop level however we find that certain non-zero tree-level processes, which are not visible in the exact solution, contribute, via the optical theorem, and give an apparent mismatch for certain amplitudes. Furthermore we find that a proposed one-loop modification of the dressing phase correctly reproduces the worldsheet calculation while the standard Hernandez-Lopez phase does not. We also compute several massless to massless processes.
Quark-hadron phase structure of QCD matter from SU(4) Polyakov linear sigma model
NASA Astrophysics Data System (ADS)
Diab, Abdel Magied Abdel Aal; Tawfik, Abdel Nasser
2018-04-01
The SU(4) Polyakov linear sigma model (PLSM) is extended towards characterizing the chiral condensates, σl, σs and σc of light, strange and charm quarks, respectively and the deconfinement order-parameters φ and φ at finite temperatures and densities (chemical potentials). The PLSM is considered to study the QCD equation of state in the presence of the chiral condensate of charm for different finite chemical potentials. The PLSM results are in a good agreement with the recent lattice QCD simulations. We conclude that, the charm condensate is likely not affected by the QCD phase-transition, where the corresponding critical temperature is greater than that of the light and strange quark condensates.
Duality and the Knizhnik-Polyakov-Zamolodchikov relation in Liouville quantum gravity.
Duplantier, Bertrand; Sheffield, Scott
2009-04-17
We present a (mathematically rigorous) probabilistic and geometrical proof of the Knizhnik-Polyakov-Zamolodchikov relation between scaling exponents in a Euclidean planar domain D and in Liouville quantum gravity. It uses the properly regularized quantum area measure dmicro_{gamma}=epsilon;{gamma;{2}/2}e;{gammah_{epsilon}(z)}dz, where dz is the Lebesgue measure on D, gamma is a real parameter, 0
Yang-Mills correlators across the deconfinement phase transition
NASA Astrophysics Data System (ADS)
Reinosa, U.; Serreau, J.; Tissier, M.; Tresmontant, A.
2017-02-01
We compute the finite temperature ghost and gluon propagators of Yang-Mills theory in the Landau-DeWitt gauge. The background field that enters the definition of the latter is intimately related with the (gauge-invariant) Polyakov loop and serves as an equivalent order parameter for the deconfinement transition. We use an effective gauge-fixed description where the nonperturbative infrared dynamics of the theory is parametrized by a gluon mass which, as argued elsewhere, may originate from the Gribov ambiguity. In this scheme, one can perform consistent perturbative calculations down to infrared momenta, which have been shown to correctly describe the phase diagram of Yang-Mills theories in four dimensions as well as the zero-temperature correlators computed in lattice simulations. In this article, we provide the one-loop expressions of the finite temperature Landau-DeWitt ghost and gluon propagators for a large class of gauge groups and present explicit results for the SU(2) case. These are substantially different from those previously obtained in the Landau gauge, which corresponds to a vanishing background field. The nonanalyticity of the order parameter across the transition is directly imprinted onto the propagators in the various color modes. In the SU(2) case, this leads, for instance, to a cusp in the electric and magnetic gluon susceptibilities as well as similar signatures in the ghost sector. We mention the possibility that such distinctive features of the transition could be measured in lattice simulations in the background field gauge studied here.
Inductively guided circuits for ultracold dressed atoms
Sinuco-León, German A.; Burrows, Kathryn A.; Arnold, Aidan S.; Garraway, Barry M.
2014-01-01
Recent progress in optics, atomic physics and material science has paved the way to study quantum effects in ultracold atomic alkali gases confined to non-trivial geometries. Multiply connected traps for cold atoms can be prepared by combining inhomogeneous distributions of DC and radio-frequency electromagnetic fields with optical fields that require complex systems for frequency control and stabilization. Here we propose a flexible and robust scheme that creates closed quasi-one-dimensional guides for ultracold atoms through the ‘dressing’ of hyperfine sublevels of the atomic ground state, where the dressing field is spatially modulated by inductive effects over a micro-engineered conducting loop. Remarkably, for commonly used atomic species (for example, 7Li and 87Rb), the guide operation relies entirely on controlling static and low-frequency fields in the regimes of radio-frequency and microwave frequencies. This novel trapping scheme can be implemented with current technology for micro-fabrication and electronic control. PMID:25348163
NASA Astrophysics Data System (ADS)
Diaz, Victor Alfonzo; Giusti, Andrea
2018-03-01
The aim of this paper is to present a simple generalization of bosonic string theory in the framework of the theory of fractional variational problems. Specifically, we present a fractional extension of the Polyakov action, for which we compute the general form of the equations of motion and discuss the connection between the new fractional action and a generalization the Nambu-Goto action. Consequently, we analyze the symmetries of the modified Polyakov action and try to fix the gauge, following the classical procedures. Then we solve the equations of motion in a simplified setting. Finally, we present a Hamiltonian description of the classical fractional bosonic string and introduce the fractional light-cone gauge. It is important to remark that, throughout the whole paper, we thoroughly discuss how to recover the known results as an "integer" limit of the presented model.
An object oriented code for simulating supersymmetric Yang-Mills theories
NASA Astrophysics Data System (ADS)
Catterall, Simon; Joseph, Anosh
2012-06-01
We present SUSY_LATTICE - a C++ program that can be used to simulate certain classes of supersymmetric Yang-Mills (SYM) theories, including the well known N=4 SYM in four dimensions, on a flat Euclidean space-time lattice. Discretization of SYM theories is an old problem in lattice field theory. It has resisted solution until recently when new ideas drawn from orbifold constructions and topological field theories have been brought to bear on the question. The result has been the creation of a new class of lattice gauge theories in which the lattice action is invariant under one or more supersymmetries. The resultant theories are local, free of doublers and also possess exact gauge-invariance. In principle they form the basis for a truly non-perturbative definition of the continuum SYM theories. In the continuum limit they reproduce versions of the SYM theories formulated in terms of twisted fields, which on a flat space-time is just a change of the field variables. In this paper, we briefly review these ideas and then go on to provide the details of the C++ code. We sketch the design of the code, with particular emphasis being placed on SYM theories with N=(2,2) in two dimensions and N=4 in three and four dimensions, making one-to-one comparisons between the essential components of the SYM theories and their corresponding counterparts appearing in the simulation code. The code may be used to compute several quantities associated with the SYM theories such as the Polyakov loop, mean energy, and the width of the scalar eigenvalue distributions. Program summaryProgram title: SUSY_LATTICE Catalogue identifier: AELS_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AELS_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC license, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 9315 No. of bytes in distributed program, including test data, etc.: 95 371 Distribution format: tar.gz Programming language: C++ Computer: PCs and Workstations Operating system: Any, tested on Linux machines Classification:: 11.6 Nature of problem: To compute some of the observables of supersymmetric Yang-Mills theories such as supersymmetric action, Polyakov/Wilson loops, scalar eigenvalues and Pfaffian phases. Solution method: We use the Rational Hybrid Monte Carlo algorithm followed by a Leapfrog evolution and a Metropolis test. The input parameters of the model are read in from a parameter file. Restrictions: This code applies only to supersymmetric gauge theories with extended supersymmetry, which undergo the process of maximal twisting. (See Section 2 of the manuscript for details.) Running time: From a few minutes to several hours depending on the amount of statistics needed.
Asymptotic One-Point Functions in Gauge-String Duality with Defects.
Buhl-Mortensen, Isak; de Leeuw, Marius; Ipsen, Asger C; Kristjansen, Charlotte; Wilhelm, Matthias
2017-12-29
We take the first step in extending the integrability approach to one-point functions in AdS/dCFT to higher loop orders. More precisely, we argue that the formula encoding all tree-level one-point functions of SU(2) operators in the defect version of N=4 supersymmetric Yang-Mills theory, dual to the D5-D3 probe-brane system with flux, has a natural asymptotic generalization to higher loop orders. The asymptotic formula correctly encodes the information about the one-loop correction to the one-point functions of nonprotected operators once dressed by a simple flux-dependent factor, as we demonstrate by an explicit computation involving a novel object denoted as an amputated matrix product state. Furthermore, when applied to the Berenstein-Maldacena-Nastase vacuum state, the asymptotic formula gives a result for the one-point function which in a certain double-scaling limit agrees with that obtained in the dual string theory up to wrapping order.
Nucleon properties in the Polyakov quark-meson model
NASA Astrophysics Data System (ADS)
Li, Yingying; Hu, Jinniu; Mao, Hong
2018-05-01
We study the nucleon as a nontopological soliton in a quark medium as well as in a nucleon medium in terms of the Polyakov quark-meson (PQM) model with two flavors at finite temperature and density. The constituent quark masses evolving with the temperature at various baryon chemical potentials are calculated and the equations of motion are solved according to the proper boundary conditions. The PQM model predicts an increasing size of the nucleon and a reduction of the nucleon mass in both hot environment. However, the phase structure is different from each other in quark and nucleon mediums. There is a crossover in the low-density region and a first-order phase transition in the high-density region in quark medium, whereas there exists a crossover characterized by the overlap of the nucleons in nucleon medium.
On non-primitively divergent vertices of Yang-Mills theory
NASA Astrophysics Data System (ADS)
Huber, Markus Q.
2017-11-01
Two correlation functions of Yang-Mills beyond the primitively divergent ones, the two-ghost-two-gluon and the four-ghost vertices, are calculated and their influence on lower vertices is examined. Their full (transverse) tensor structure is taken into account. As input, a solution of the full two-point equations - including two-loop terms - is used that respects the resummed perturbative ultraviolet behavior. A clear hierarchy is found with regard to the color structure that reduces the number of relevant dressing functions. The impact of the two-ghost-two-gluon vertex on the three-gluon vertex is negligible, which is explained by the fact that all non-small dressing functions drop out due to their color factors. Only in the ghost-gluon vertex a small net effect below 2% is seen. The four-ghost vertex is found to be extremely small in general. Since these two four-point functions do not enter into the propagator equations, these findings establish their small overall effect on lower correlation functions.
One-dimensional QCD in thimble regularization
NASA Astrophysics Data System (ADS)
Di Renzo, F.; Eruzzi, G.
2018-01-01
QCD in 0 +1 dimensions is numerically solved via thimble regularization. In the context of this toy model, a general formalism is presented for S U (N ) theories. The sign problem that the theory displays is a genuine one, stemming from a (quark) chemical potential. Three stationary points are present in the original (real) domain of integration, so that contributions from all the thimbles associated to them are to be taken into account: we show how semiclassical computations can provide hints on the regions of parameter space where this is absolutely crucial. Known analytical results for the chiral condensate and the Polyakov loop are correctly reproduced: this is in particular trivial at high values of the number of flavors Nf. In this regime we notice that the single thimble dominance scenario takes place (the dominant thimble is the one associated to the identity). At low values of Nf computations can be more difficult. It is important to stress that this is not at all a consequence of the original sign problem (not even via the residual phase). The latter is always under control, while accidental, delicate cancelations of contributions coming from different thimbles can be in place in (restricted) regions of the parameter space.
Three dimensional finite temperature SU(3) gauge theory near the phase transition
NASA Astrophysics Data System (ADS)
Bialas, P.; Daniel, L.; Morel, A.; Petersson, B.
2013-06-01
We have measured the correlation function of Polyakov loops on the lattice in three dimensional SU(3) gauge theory near its finite temperature phase transition. Using a new and powerful application of finite size scaling, we furthermore extend the measurements of the critical couplings to considerably larger values of the lattice sizes, both in the temperature and space directions, than was investigated earlier in this theory. With the help of these measurements we perform a detailed finite size scaling analysis, showing that for the critical exponents of the two dimensional three state Potts model the mass and the susceptibility fall on unique scaling curves. This strongly supports the expectation that the gauge theory is in the same universality class. The Nambu-Goto string model on the other hand predicts that the exponent ν has the mean field value, which is quite different from the value in the abovementioned Potts model. Using our values of the critical couplings we also determine the continuum limit of the value of the critical temperature in terms of the square root of the zero temperature string tension. This value is very near to the prediction of the Nambu-Goto string model in spite of the different critical behaviour.
NASA Astrophysics Data System (ADS)
Di Stefano, Omar; Stassi, Roberto; Garziano, Luigi; Frisk Kockum, Anton; Savasta, Salvatore; Nori, Franco
2017-05-01
In quantum field theory, bare particles are dressed by a cloud of virtual particles to form physical particles. The virtual particles affect properties such as the mass and charge of the physical particles, and it is only these modified properties that can be measured in experiments, not the properties of the bare particles. The influence of virtual particles is prominent in the ultrastrong-coupling regime of cavity quantum electrodynamics (QED), which has recently been realised in several condensed-matter systems. In some of these systems, the effective interaction between atom-like transitions and the cavity photons can be switched on or off by external control pulses. This offers unprecedented possibilities for exploring quantum vacuum fluctuations and the relation between physical and bare particles. We consider a single three-level quantum system coupled to an optical resonator. Here we show that, by applying external electromagnetic pulses of suitable amplitude and frequency, each virtual photon dressing a physical excitation in cavity-QED systems can be converted into a physical observable photon, and back again. In this way, the hidden relationship between the bare and the physical excitations can be unravelled and becomes experimentally testable. The conversion between virtual and physical photons can be clearly pictured using Feynman diagrams with cut loops.
Solitons, τ-functions and hamiltonian reduction for non-Abelian conformal affine Toda theories
NASA Astrophysics Data System (ADS)
Ferreira, L. A.; Miramontes, J. Luis; Guillén, Joaquín Sánchez
1995-02-01
We consider the Hamiltonian reduction of the "two-loop" Wess-Zumino-Novikov-Witten model (WZNW) based on an untwisted affine Kac-Moody algebra G. The resulting reduced models, called Generalized Non-Abelian Conformal Affine Toda (G-CAT), are conformally invariant and a wide class of them possesses soliton solutions; these models constitute non-Abelian generalizations of the conformal affine Toda models. Their general solution is constructed by the Leznov-Saveliev method. Moreover, the dressing transformations leading to the solutions in the orbit of the vacuum are considered in detail, as well as the τ-functions, which are defined for any integrable highest weight representation of G, irrespectively of its particular realization. When the conformal symmetry is spontaneously broken, the G-CAT model becomes a generalized affine Toda model, whose soliton solutions are constructed. Their masses are obtained exploring the spontaneous breakdown of the conformal symmetry, and their relation to the fundamental particle masses is discussed. We also introduce what we call the two-loop Virasoro algebra, describing extended symmetries of the two-loop WZNW models.
Primordial power spectra for scalar perturbations in loop quantum cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Blas, Daniel Martín; Olmedo, Javier, E-mail: d.martindeblas@uandresbello.edu, E-mail: jolmedo@lsu.edu
We provide the power spectrum of small scalar perturbations propagating in an inflationary scenario within loop quantum cosmology. We consider the hybrid quantization approach applied to a Friedmann-Robertson-Walker spacetime with flat spatial sections coupled to a massive scalar field. We study the quantum dynamics of scalar perturbations on an effective background within this hybrid approach. We consider in our study adiabatic states of different orders. For them, we find that the hybrid quantization is in good agreement with the predictions of the dressed metric approach. We also propose an initial vacuum state for the perturbations, and compute the primordial andmore » the anisotropy power spectrum in order to qualitatively compare with the current observations of Planck mission. We find that our vacuum state is in good agreement with them, showing a suppression of the power spectrum for large scale anisotropies. We compare with other choices already studied in the literature.« less
Intrinsic non-commutativity of closed string theory
Freidel, Laurent; Leigh, Robert G.; Minic, Djordje
2017-09-14
We show that the proper interpretation of the cocycle operators appearing in the physical vertex operators of compactified strings is that the closed string target is noncommutative. We track down the appearance of this non-commutativity to the Polyakov action of the at closed string in the presence of translational monodromies (i.e., windings). Here, in view of the unexpected nature of this result, we present detailed calculations from a variety of points of view, including a careful understanding of the consequences of mutual locality in the vertex operator algebra, as well as a detailed analysis of the symplectic structure of themore » Polyakov string. Finally, we also underscore why this non-commutativity was not emphasized previously in the existing literature. This non-commutativity can be thought of as a central extension of the zero-mode operator algebra, an effect set by the string length scale $-$ it is present even in trivial backgrounds. Clearly, this result indicates that the α'→0 limit is more subtle than usually assumed.« less
Intrinsic non-commutativity of closed string theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freidel, Laurent; Leigh, Robert G.; Minic, Djordje
We show that the proper interpretation of the cocycle operators appearing in the physical vertex operators of compactified strings is that the closed string target is noncommutative. We track down the appearance of this non-commutativity to the Polyakov action of the at closed string in the presence of translational monodromies (i.e., windings). Here, in view of the unexpected nature of this result, we present detailed calculations from a variety of points of view, including a careful understanding of the consequences of mutual locality in the vertex operator algebra, as well as a detailed analysis of the symplectic structure of themore » Polyakov string. Finally, we also underscore why this non-commutativity was not emphasized previously in the existing literature. This non-commutativity can be thought of as a central extension of the zero-mode operator algebra, an effect set by the string length scale $-$ it is present even in trivial backgrounds. Clearly, this result indicates that the α'→0 limit is more subtle than usually assumed.« less
On a local solvability and stability of the inverse transmission eigenvalue problem
NASA Astrophysics Data System (ADS)
Bondarenko, Natalia; Buterin, Sergey
2017-11-01
We prove a local solvability and stability of the inverse transmission eigenvalue problem posed by McLaughlin and Polyakov (1994 J. Diff. Equ. 107 351-82). In particular, this result establishes the minimality of the data used therein. The proof is constructive.
Emerging geometry from maximally super-symmetric Yang-Mills theory
NASA Astrophysics Data System (ADS)
Vazquez, Samuel Enrique
In this thesis, we explore the emergence of space-time geometry, and string theory physics from N = 4 supersymmetric Yang-Mills (SYM) theory with gauge group U(N). This is done in the context of the anti-de-Sitter/conformal field theory correspondence (AdS/CFT). The main results of this thesis are the following. First, we study single trace perturbations around generic 1/2 BPS states of the theory. We do this in the large N limit, and at one-loop in the 't-Hooft coupling. We show how these states can be mapped to dynamical lattices with boson statistics and periodic boundary conditions. By dynamical, we mean that the total boson occupation number is not conserved in general. Then, we show how to derive an effective sigma model for these systems which coincides with the Polyakov action of a probe string on a 1/2 BPS geometry (in the fast string limit). Secondly, we study non-supersymmetric perturbations of the vacuum which give rise to bosonic lattices with open boundary conditions. We also do this in the large N limit, and at one-loop in the 't-Hooft coupling. We show that these states are dual to open strings on D3-branes known as "Giant Gravitons". These lattice systems are also dynamical, but in some special cases, we show that we get an integrable spin chain with open boundary conditions. Next, we study single trace perturbations at strong coupling. We do this by taking a "dilute gas" approximation. We derive an all-loop result for the dispersion relation of the "magnons" which coincides with previous conjectures in the literature. What is more, we derive the geometrical picture of the so-called "giant magnon" string solution of Hofman and Maldacena, directly from the field theory. Finally, we explore the question of classical integrability of open strings on D-branes. In particular, we study the case of the giant gravitons, and compare the integrable structures on both sides of the AdS/CFT correspondence.
Monopole-antimonopole interaction potential
NASA Astrophysics Data System (ADS)
Saurabh, Ayush; Vachaspati, Tanmay
2017-11-01
We numerically study the interactions of twisted monopole-antimonopole pairs in the 't Hooft-Polyakov model for a range of values of the scalar to vector mass ratio. We also recover the sphaleron solution at maximum twist discovered by Taubes [Commun. Math. Phys. 86, 257 (1982), 10.1007/BF01206014] and map out its energy and size as functions of parameters.
Sunlight, Sea Ice, and the Ice Albedo Feedback in a Changing Arctic Sea Ice Cover
2015-09-30
PUBLICATIONS Carmack, E .; I. Polyakov; L. Padman; I. Fer; E . Hunke; J. Hutchings; J. Jackson; D. Kelley; R. Kwok; C. Layton ; D.K. Perovich; O. Persson; B...Heygster, M. Huntemann, P. Schwarz, G. Birnbaum, C. Polashenski, D. Perovich, E . Zege, A. Malinka and A. Prikchach (2015), The melt pond fraction and
Hickerson, W L; Kealey, G P; Smith, D J; Thomson, P D
1994-01-01
Three institutions enrolled 38 patients who required bilateral skin graft donor sites into a safety and efficacy study of a new synthetic donor site dressing. Bilateral donor sites were randomized to receive either a new, synthetic donor site dressing or an impregnated gauze dressing. Wounds were assessed by time to healing, pain, and patient preference. Synthetic dressing wounds were treated 7.9 days compared with 10.2 days for gauze dressing wounds (p < 0.001), and synthetic dressing wounds were more completely epithelialized. Visual analogue pain analysis revealed significantly less donor site pain with synthetic dressing (2.94) versus gauze dressing (4.64) (p < 0.001). Synthetic dressing had fewer treatment-related adverse experiences than gauze dressing (2 vs 7) and was judged by recipients to be superior to gauze dressing in comfort, pain relief, cosmetic appeal, ease of ambulation, and overall acceptance.
Non-Abelian Yang-Mills analogue of classical electromagnetic duality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Hong-Mo; Faridani, J.; Tsun, T.S.
The classic question of non-Abelian Yang-Mills analogue to electromagnetic duality is examined here in a minimalist fashion at the strictly four-dimensional, classical field, and point charge level. A generalization of the Abelian Hodge star duality is found which, though not yet known to give dual symmetry, reproduces analogues to many dual properties of the Abelian theory. For example, there is a dual potential, but it is a two-indexed tensor {ital T}{sub {mu}{nu}} of the Freedman-Townsend-type. Though not itself functioning as such, {ital T}{sub {mu}{nu}} gives rise to a dual parallel transport {ital {tilde A}}{sub {mu}} for the phase of themore » wave function of the color magnetic charge, this last being a monopole of the Yang-Mills field but a source of the dual field. The standard color (electric) charge itself is found to be a monpole of {ital {tilde A}}{sub {mu}}. At the same time, the gauge symmetry is found doubled from say SU({ital N}) to SU({ital N}){times}SU({ital N}). A novel feature is that all equations of motion, including the standard Yang-Mills and Wong equations, are here derived from a ``universal`` principle, namely, the Wu-Yang criterion for monpoles, where interactions arise purely as a consequence of the topological definition of the monopole charge. The technique used is the loop space formulation of Polyakov.« less
Features and flaws of a contact interaction treatment of the kaon
NASA Astrophysics Data System (ADS)
Chen, Chen; Chang, Lei; Roberts, Craig D.; Schmidt, Sebastian M.; Wan, Shaolong; Wilson, David J.
2013-04-01
Elastic and semileptonic transition form factors for the kaon and pion are calculated using the leading order in a global-symmetry-preserving truncation of the Dyson-Schwinger equations and a momentum-independent form for the associated kernels in the gap and Bethe-Salpeter equations. The computed form factors are compared both with those obtained using the same truncation but an interaction that preserves the one-loop renormalization-group behavior of QCD and with data. The comparisons show that in connection with observables revealed by probes with |Q2|≲M2, where M≈0.4GeV is an infrared value of the dressed-quark mass, results obtained using a symmetry-preserving regularization of the contact interaction are not realistically distinguishable from those produced by more sophisticated kernels, and available data on kaon form factors do not extend into the domain whereupon one could distinguish among the interactions. The situation differs if one includes the domain Q2>M2. Thereupon, a fully consistent treatment of the contact interaction produces form factors that are typically harder than those obtained with QCD renormalization-group-improved kernels. Among other things also described are a Ward identity for the inhomogeneous scalar vertex, similarity between the charge distribution of a dressed u quark in the K+ and that of the dressed u quark in the π+, and reflections upon the point whereat one might begin to see perturbative behavior in the pion form factor. Interpolations of the form factors are provided, which should assist in working to chart the interaction between light quarks by explicating the impact on hadron properties of differing assumptions about the behavior of the Bethe-Salpeter kernel.
Fraser, John F; Bodman, Jan; Sturgess, Ruth; Faoagali, Joan; Kimble, Roy M
2004-02-01
Burn sepsis is a leading cause of mortality and morbidity in patients with major burns. The use of topical anti-microbial agents has helped improve the survival in these patients. There are a number of anti-microbials available, one of which, Silvazine (1% silver sulphadiazine (SSD) and 0.2% chlorhexidine digluconate), is used only in Australasia. No study, in vitro or clinical, had compared Silvazine with the new dressing Acticoat. This study compared the anti-microbial activity of Silvazine, Acticoat and 1% silver sulphadiazine (Flamazine) against eight common burn wound pathogens. Each organism was prepared as a suspension. A 10 microl inoculum of the chosen bacterial isolate (representing approximately between 10(4) and 10(5) total bacteria) was added to each of four vials, followed by samples of each dressing and a control. The broths were then incubated and 10 microl loops removed at specified intervals and transferred onto Horse Blood Agar. These plates were then incubated for 18 hours and a colony count was performed. The data demonstrates that the combination of 1% SSD and 0.2% chlorhexidine digluconate (Silvazine) results in the most effective killing of all bacteria. SSD and Acticoat had similar efficacies against a number of isolates, but Acticoat seemed only bacteriostatic against E. faecalis and methicillin-resistant Staphylococcus aureus. Viable quantities of Enterobacter cloacae and Proteus mirabilis remained at 24h. The combination of 1% SSD and 0.2% chlorhexidine digluconate (Silvazine) is a more effective anti-microbial against a number of burn wound pathogens in this in vitro study. A clinical study of its in vivo anti-microbial efficacy is required.
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
Comparison of two silver dressings for wound management in pediatric burns.
Jester, Ingo; Bohn, Ingo; Hannmann, Thorsten; Waag, Karl-Ludwig; Loff, Steffan
2008-11-01
Purpose. Silver wound dressings are widely used in the treatment of burns. Dressings differ in material characteristics, various antimicrobial activities, and ease of use. The purpose of this study was to evaluate both dressing performance and amount of pain during the dressing changes of 2 silver dressings Urgotul SSD® (Laboratoires Urgo, Chenove, France), and Contreet Ag® (Coloplast, Minneapolis, MN) in children. A retrospective cohort study was performed with 2 groups of 20 burns treated with Urgotul SSD and Contreet Ag until the wounds were healed or grafted. Seventy dressing changes in the Contreet Ag group and 67 dressing changes in the Urgotul group were evaluated. Every dressing change was assessed regarding the dressing performance (exudate, adherence, bleeding, and dressing application/removal), and pain. Pain was "absent or slight" in 61 (92%) dressing changes with Urgotul SSD, and in 60 (85%) of the dressing changes with Contreet Ag. Dressing application in the Urgotul group was more often "very easy" (n = 33; 49%) or "easy" (n = 32; 48%) than in the Contreet Ag group, "very easy" (n = 25; 35%), and "easy" (n = 42; 60%). Contreet Ag had a greater ability to absorb exudate ("very good" n = 60; 85%, and "good" n = 11; 15%) than Urgotul SSD ("very good" n = 34; 51%, and "good" n = 13; 19%). Urgotul SSD and Contreet Ag are comparable regarding pain during dressing change. The dressings differ in their ability to absorb exudate and ease of application. Both dressings provided nearly painless wound management, and therefore were highly accepted by the nurses and especially the children being treated.
Choosing a Wound Dressing Based on Common Wound Characteristics
Dabiri, Ganary; Damstetter, Elizabeth; Phillips, Tania
2016-01-01
Significance: Chronic wounds are a major healthcare burden.The practitioner should have an appropriate understanding of both the etiology of the wound as well as the optimal type of dressings to use. Fundamental wound characteristics may be used to guide the practitioner's choice of dressings. The identification of optimal dressings to use for a particular wound type is an important element in facilitating wound healing. Recent Advances: Researchers have sought to design wound dressings that aim to optimize each stage in the healing process. In addition, dressings have been designed to target and kill infection-causing bacteria, with the incorporation of antimicrobial agents. Critical Issues: Chronic wounds are frequently dynamic in presentation, and the numerous wound dressings available make dressing selection challenging for the practitioner. Choosing the correct dressing decreases time to healing, provides cost-effective care, and improves patient quality of life. Future Directions: Research into the mechanisms of wound healing has enhanced our ability to heal chronic wounds at a faster rate through the use of moisture-retentive dressings. Newer dressings are incorporating the use of nanotechnology by incorporating miniature electrical sensors into the dressing. These dressings are engineered to detect changes in a wound environment and alert the patient or practitioner by altering the color of the dressing or sending a message to a smartphone. Additional investigations are underway that incorporate biologic material such as stem cells into dressings. PMID:26858913
Evaluation of a non-adherent, povidone-iodine dressing in a case series of chronic wounds.
Campbell, N; Campbell, D
2013-08-01
Here we report a product evaluation for a non-adherent, povidone-iodine (PVP-I) dressing, determining the clinical need for the product, performing a literature review, clinical evaluation and cost-analysis, and developing a recommendation. This evaluation included 20 patients who experienced dressing pain with the previous antimicrobial dressing. Two patients discontinued the evaluation and four ulcers were non-healing; the remaining wounds closed with the PVP-I dressing. Patients indicated a preference for the PVP-I dressing, primarily due to lack of dressing pain. The PVP-I dressing was also the most cost-efficient.
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Hormbrey, E; Pandya, A; Giele, H
2003-07-01
Painful split-skin-graft donor sites remain a common problem for patients. We undertook a prospective randomised trial to examine the comparative comfort and ease of care of two different donor-site dressings. One dressing is the alginate Kaltostat, the standard plastic-surgical dressing in the UK and abroad, and the other is the adhesive retention tape Mefix, a novel use of a readily available dressing. We randomised 50 patients requiring split-skin grafts to receive either alginate (Kaltostat) or retention (Mefix) donor-site dressings. Dressings were assessed by interview and questionnaire at 24, 72 h and 2 weeks, and by wound review at 2 weeks. Retention dressings were found to be more comfortable, required less nursing intervention and allowed patients easier mobility with a greater range of daily activities, especially washing, without compromising wound healing. We recommend adhesive retention dressings as cost-effective comfortable dressings, which readily conform to any donor site.
Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study.
McColl, David; Cartlidge, Brian; Connolly, Patricia
2007-10-01
Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time. A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate flow. Eight monitoring points, situated beneath the test dressing, allow the moisture profile across the complete dressing to be measured both during and after fluid injection. The system has been used to evaluate the performance of four foam dressings, a composite hydrofibre dressing and a film dressing. Stark contrasts in the performance of the wound contact layer were found between the different wound dressing types. The composite hydrofibre dressing retained moisture at the wound interface throughout the experiments while areas of the foam dressing quickly became dry, even during constant injection of fluid. The abundance of sensors allowed a moisture map of the surface of the wound dressing to be constructed, illustrating that the moisture profile was not uniform across several of the dressings tested during absorption and evaporation of liquid. These results raise questions as to how the dressings behave on a wound in vivo and indicate the need for a similar clinical monitoring system for tracking wound moisture levels.
ERIC Educational Resources Information Center
Birel, Firat Kiyas
2016-01-01
Problem Statement: Dressing for school has been intensely disputed and has led to periodic changes in dress codes since the foundation of the Turkish republic. Practitioners have tried to put some new practices related to school dress codes into practice for redressing former dress code issues involving mandatory dress standards for both students…
Australasian survey of split skin graft donor site dressings.
Lyall, P W; Sinclair, S W
2000-02-01
There is an ever increasing array of products available for wound dressings. The aim of the present study was to establish which dressings should be used as standard controls for future studies; what factors are regarded as most important in assessing a dressing; what the level of satisfaction is with the available products; what the strengths and weaknesses of the commonly used dressings are; and what dressings would be preferred if cost were no issue. A postal survey was sent to every plastic and reconstructive surgeon registered in Australasia (n = 217). A total of 53% responded. The most commonly used dressing type overall is the calcium alginates, despite the fact that they were not the highest performing dressings. This is also the most commonly used in Australia. In contrast scarlet red is still used most commonly in New Zealand. The level of satisfaction with the most commonly used dressing varied very little. The factor regarded most important was patient comfort level. A profile of the commonly used dressing was constructed. Calcium alginates and or scarlet red should be used as the control for new product comparisons. Most of the respondents were satisfied with their preferred dressing and were not interested in trying alternative dressings.
Edwards, Melannie; Rickard, Claire M; Rapchuk, Ivan; Corley, Amanda; Marsh, Nicole; Spooner, Amy J; Mihala, Gabor; Fraser, John F
2014-09-01
To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012. Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood). Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01). AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.
Dressing remedies: a concept for improving access to and use of dressings in nursing homes.
Clarkson, A
2007-01-01
Delays in accessing dressings prescribed by general practitioners can result in the inappropriate use of dressings on more than one resident in nursing homes. The dressing remedies concept was developed to overcomes this problem.
Matiasek, J; Domig, K J; Djedovic, G; Babeluk, R; Assadian, O
2017-05-02
The aim of this study was to investigate the bacterial bioburden in experimental in vitro wounds during the application of conventional negative pressure wound therapy (NPWT), with and without antimicrobial dressings (polyhexanide, silver), against NPWT instillation of octenidine. Experimental wounds produced in an in vitro porcine wound model were homogenously contaminated with bacterial suspension and treated with NPWT and different options. Group A: non-antimicrobial polyurethane foam dressing; group B: antimicrobial polyurethane foam dressing containing silver; group C: antimicrobial gauze dressing containing polyhexanide; group D: non-antimicrobial polyurethane foam dressing intermittently irrigated with octenidine; group E: negative control (non-antimicrobial polyurethane foam dressing without NPWT). Standard biopsies were harvested after 24 and 28 hours. This study demonstrated that the use of NPWT with intermitted instillation of octenidine (group D) or application of silver-based polyurethane foam dressings (group B) is significantly superior against Staphylococcus aureus colonisation in experimental wounds compared with non-antimicrobial polyurethane foam dressing (group A) after 48 hours. Surprisingly, the polyhexanide-based dressing (group C) used in this model showed no statistical significant effect compared with the control group (group E) after 24 or 48 hours of treatment. Both intermitted instillation of octenidine and silver-based dressings in standard NPWT were significantly superior compared with non-antimicrobial polyurethane foam dressings or PHMB coated gauze dressing after 48 hours.
Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.
Mushahar, Lily; Mei, Lim Wei; Yusuf, Wan Shaariah; Sivathasan, Sudhaharan; Kamaruddin, Norilah; Idzham, Nor Juliana Mohd
2016-01-01
♦ Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦ A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦ A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦ Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables. Copyright © 2016 International Society for Peritoneal Dialysis.
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate.
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L; Carty, Neal; Johnson, Peter
2015-01-01
Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes.
NASA Astrophysics Data System (ADS)
Carlomagno, J. P.
2018-05-01
We study the features of a nonlocal SU(3) Polyakov-Nambu-Jona-Lasinio model that includes wave-function renormalization. Model parameters are determined from vacuum phenomenology considering lattice-QCD-inspired nonlocal form factors. Within this framework, we analyze the properties of light scalar and pseudoscalar mesons at finite temperature and chemical potential determining characteristics of deconfinement and chiral restoration transitions.
Closed dressings after laser skin resurfacing.
Newman, J P; Koch, R J; Goode, R L
1998-07-01
To evaluate the safety, efficacy, and patient acceptance of closed dressings after full facial resurfacing with the carbon dioxide laser. Prospective cohort of men and women undergoing full facial carbon dioxide laser resurfacing. Ambulatory surgical center at a university hospital. Forty consecutive patients randomized to 1 of 4 dressing groups. All patients underwent full facial resurfacing with a carbon dioxide laser system. One of 5 closed dressings (single- or 3-layer composite foam, plastic mesh, hydrogel, or polymer film) was placed immediately after the procedure. Closed dressings were changed on postoperative day 2 and removed on postoperative day 4. Objective postoperative criteria of erythema, scarring, reepithelialization, and surface irregularities were recorded and photodocumented. Comparisons were made among the closed dressing groups as well as with a group of historical control subjects treated with open dressings. The ease of application, office time for preparation and application, and cost of the individual dressings were collected. Patient characteristics of overall acceptance, comfort, and ease of maintenance were recorded with a visual analog scale. There were no complications of scarring, surface irregularities, or contact dermatitis from the application or maintenance of the closed dressings. There were no significant differences in the number of days of postoperative erythema or in the rate of facial reepithelialization among the groups. Most patients preferred not to continue with the closed dressings past 2 days. Positive features from the use of closed dressings included reduction in crust formation, decreased pruritus, decreased erythema, and decreased postoperative pain, compared with historical controls. Negative features included time in preparation and application of the dressings. Costs ranged from $9.79 to $50 per dressing change. Closed dressings are safe and offer benefits noted during the first 4 postoperative days. Patients can be expected to maintain a closed dressing for at least 24 hours but no longer than 4 days. The positive features of closed dressings and patient acceptance outweigh the cost and office time involved with their application and maintenance.
Dyons near the transition temperature in SU(3) lattice gluodynamics
NASA Astrophysics Data System (ADS)
Bornyakov, V. G.; Ilgenfritz, E.-M.; Martemyanov, B. V.
2018-05-01
We study the topological structure of SU(3) lattice gluodynamics by cluster analysis. This methodological study is meant as preparation for full QCD. The topological charge density is becoming visible in the process of over-improved gradient flow, which is monitored by means of the inverse participation ratio. The flow is stopped at the moment when calorons dissociate into dyons due to the over-improved character of the underlying action. This gives the possibility to simultaneously detect all three dyonic constituents of KvBLL calorons in the gluonic field. The behavior of the average Polyakov loop (PL) under (over-improved) gradient flow could also serve as a diagnostics for the actual phase the configuration is belonging to. Time-like Abelian monopole currents and specific patterns of the local PL are correlated with the topological clusters. The spectrum of reconstructed cluster charges Q cl corresponds to the phases. It is scattered around Q cl ≈ ±1/3 in the confined phase, whereas it is Q cl ≈ ±(0.5 ÷ 0.7) for heavy dyons and | {Q}{{cl}}| < 0.3 for light dyons in the deconfined phase. We estimate the density of heavy and light dyons at three values of temperature. We find that heavy dyons are increasingly suppressed with increasing temperature. The paper is dedicated to the memory of Michael Müller-Preussker who was a member of our research group for more than twenty years.
NASA Astrophysics Data System (ADS)
Ishii, Masahiro; Kouno, Hiroaki; Yahiro, Masanobu
2017-06-01
We propose a practical effective model by introducing temperature (T ) dependence to the coupling strengths of four-quark and six-quark Kobayashi-Maskawa-'t Hooft interactions in the 2 +1 flavor Polyakov-loop extended Nambu-Jona-Lasinio model. The T dependence is determined from lattice QCD (LQCD) data on the renormalized chiral condensate around the pseudocritical temperature Tcχ of chiral crossover and the screening-mass difference between π and a0 mesons in T >1.1 Tcχ where only the U (1 )A-symmetry breaking survives. The model well reproduces LQCD data on screening masses Mξscr(T ) for both pseudoscalar mesons (ξ =π ,K ,η ,η' ) and scalar ones (ξ =a0,κ ,σ ,f0 ), particularly in T ≳Tcχ . Using this effective model, we predict meson pole masses Mξpole(T ) for scalar and pseudoscalar mesons. For η' meson, the prediction is consistent with the experimental value at finite T measured in heavy-ion collisions. We point out that the relation Mξscr(T )-Mξpole(T )≈Mξ' scr(T )-Mξ' pole(T ) is pretty good when ξ and ξ' are the scalar mesons, and show that the relation Mξscr(T )/Mξ' scr(T )≈Mξpole(T )/Mξ' pole(T ) is well satisfied within 20% error when ξ and ξ' are the pseudoscalar mesons and also when ξ and ξ' are the scalar mesons.
McDonald, Kyla P.; Ma, Lili
2015-01-01
This research explored whether children judge the knowledge state of others and selectively learn novel information from them based on how they dress. The results indicated that 4- and 6-year-olds identified a formally dressed individual as more knowledgeable about new things in general than a casually dressed one (Study 1). Moreover, children displayed an overall preference to seek help from a formally dressed individual rather than a casually dressed one when learning about novel objects and animals (Study 2). These findings are discussed in relation to the halo effect, and may have important implications for child educators regarding how instructor dress might influence young students’ knowledge attribution and learning preferences. PMID:26636980
Are biopolymers potential deodourising agents in wound management?
Lee, G; Anand, S C; Rajendran, S
2009-07-01
To investigate the odour-adsorbing properties of biopolymers, with a view to using the findings to develop a novel dressing with odour-adsorbing properties. The odour-adsorbing properties of a selection of biopolymers (aloe vera, tea tree oil, neem oil and manuka honey) and three commercially available dressings containing activated charcoal cloth (ACC) were quantitatively assessed using laboratory test equipment. An aloe vera-containing composite dressing, designed and developed by the authors, was also compared with the ACC dressings. Aloe vera was the most adsorbent of the biopolymers and a 40% dilution had comparable values to those of the ACC dressings. Furthermore, values for the novel composite dressing were similar to those of the ACC dressings. The novel composite dressing may be a potential alternative to ACC dressings, and has the added advantages of having antimicrobial properties as well as the ability to promote a moist wound environment. However, more research is needed.
Dressing disrupted: negotiating care through the materiality of dress in the context of dementia.
Buse, Christina; Twigg, Julia
2018-02-01
This paper explores how the materiality of dress mediates and shapes practices of care in the context of dementia. Earlier research called for an approach to conceptualising care that recognised the role played by everyday artefacts. We extend this to a consideration of dress and dressing the body in relation to people with dementia that involves the direct manipulation of material objects, as well as the materiality of bodies. The paper draws on an ESRC funded study Dementia and Dress, which examined experiences of dress for people with dementia, families and care-workers using ethnographic and qualitative methods. Our analysis explores the process of dressing the body, the physicality of guiding and manipulating bodies into clothing, dealing with fabrics and bodies which 'act back' and are resistant to the process of dressing. We consider how the materiality of clothing can constrain or enable practices of care, exploring tensions between garments that support ease of dressing and those that sustain identity. Examining negotiations around dress also reveals tensions between competing 'logics' of care (Mol ). © 2018 The Authors. Sociology of Health & Illness published by John Wiley & Sons Ltd on behalf of Foundation for SHIL.
Effect of periodontal dressings on human gingiva fibroblasts in vitro
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eber, R.M.; Shuler, C.F.; Buchanan, W.
1989-08-01
In vitro cytotoxicity studies of periodontal dressings have not generally produced a result consistent with in vivo observations. These prior in vitro studies have not used human intraoral cell lines. We tested the effects of two eugenol containing and two non-eugenol periodontal dressings on cultured human gingival fibroblasts (HGF) (ATCC No. 1292). Replicate HGF cultures grown in microtiter plates were exposed to stock, 1:4 and 1:16 dilutions of extracts made from each of the four periodontal dressings. The HGF cultures were pulse labelled with tritiated thymidine (3HTdR) after 24, 48, and 72 hours. Incorporations of the labelled thymidine were measuredmore » using liquid scintillation counting and expressed as counts per minute. The results showed that undiluted extracts from all four periodontal dressings totally inhibited 3HTdR uptake (P less than 0.05). The 1:4 dilution of eugenol dressings inhibited 3HTdR uptake significantly more than non-eugenol dressings (P less than 0.05). Interestingly, at 72 hours the 1:16 dilution of the non-eugenol dressings caused significantly increased 3HTdR uptake which was not observed with the eugenol dressings. The present results suggest that the use of a human fibroblastic cell line for testing the effects of periodontal dressings may provide information about the relative biological effects of these dressings. Using this cell line, we have found that eugenol dressings inhibit fibroblast proliferation to a greater extent than non-eugenol dressings.« less
Mahoney, Diane Feeney; Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Mahoney, Edward Leo
2015-01-01
Background Prior research has critiqued the lack of attention to the stressors associated with dementia related dressing issues, stigmatizing patient clothing, and wearable technology challenges. This paper describes the conceptual development and feasibility testing of an innovative ‘smart dresser’ context aware affective system (DRESS) to enable dressing by people with moderate memory loss through individualized audio and visual task prompting in real time. Methods Mixed method feasibility study involving qualitative focus groups with 25 Alzheimer’s family caregivers experiencing dressing difficulties to iteratively inform system design and a quantitative usability trial with 10 healthy subjects in a controlled laboratory setting to assess validity of technical operations. Results Caregivers voiced the need for tangible dressing assistance to reduce their frustration from time spent in repetitive cueing and power struggles over dressing. They contributed 6 changes that influenced the prototype development, most notably adding a dresser top iPad to mimic a familiar ‘TV screen’ for the audio and visual cueing. DRESS demonstrated promising overall functionality, however the validity of identification of dressing status ranged from 0% for the correct pants dressing to 100% for all shirts dressing scenarios. Adjustments were made to the detection components of the system raising the accuracy of detection of all acted dressing scenarios for pants from 50% to 82%. Conclusions Findings demonstrate family caregiver acceptability of the proposed system, the successful interoperability of the built system’s components, and the system’s ability to interpret correct and incorrect dressing actions in controlled laboratory simulations. Future research will advance the system to the alpha stage and subsequent testing with end users in real world settings. PMID:26321895
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false French dressing. 169.115 Section 169.115 Food and... § 169.115 French dressing. (a) Description. French dressing is the separable liquid food or the..., lecithin, or polyglycerol esters of fatty acids. (d) Nomenclature. The name of the food is “French dressing...
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L.; Carty, Neal; Johnson, Peter
2015-01-01
Background Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Methods Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. Results The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. Conclusion The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes. PMID:26599087
NASA Astrophysics Data System (ADS)
Aleksandrova, Irina
2016-01-01
The existing studies, concerning the dressing process, focus on the major influence of the dressing conditions on the grinding response variables. However, the choice of the dressing conditions is often made, based on the experience of the qualified staff or using data from reference books. The optimal dressing parameters, which are only valid for the particular methods and dressing and grinding conditions, are also used. The paper presents a methodology for optimization of the dressing parameters in cylindrical grinding. The generalized utility function has been chosen as an optimization parameter. It is a complex indicator determining the economic, dynamic and manufacturing characteristics of the grinding process. The developed methodology is implemented for the dressing of aluminium oxide grinding wheels by using experimental diamond roller dressers with different grit sizes made of medium- and high-strength synthetic diamonds type ??32 and ??80. To solve the optimization problem, a model of the generalized utility function is created which reflects the complex impact of dressing parameters. The model is built based on the results from the conducted complex study and modeling of the grinding wheel lifetime, cutting ability, production rate and cutting forces during grinding. They are closely related to the dressing conditions (dressing speed ratio, radial in-feed of the diamond roller dresser and dress-out time), the diamond roller dresser grit size/grinding wheel grit size ratio, the type of synthetic diamonds and the direction of dressing. Some dressing parameters are determined for which the generalized utility function has a maximum and which guarantee an optimum combination of the following: the lifetime and cutting ability of the abrasive wheels, the tangential cutting force magnitude and the production rate of the grinding process. The results obtained prove the possibility of control and optimization of grinding by selecting particular dressing parameters.
Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta
2012-01-01
Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.
Nanofibrillar cellulose wound dressing in skin graft donor site treatment.
Hakkarainen, T; Koivuniemi, R; Kosonen, M; Escobedo-Lucea, C; Sanz-Garcia, A; Vuola, J; Valtonen, J; Tammela, P; Mäkitie, A; Luukko, K; Yliperttula, M; Kavola, H
2016-12-28
Although new therapeutic approaches for burn treatment have made progress, there is still need for better methods to enhance wound healing and recovery especially in severely burned patients. Nanofibrillar cellulose (NFC) has gained attention due to its renewable nature, good biocompatibility and excellent physical properties that are of importance for a range of applications in pharmaceutical and biomedical fields. In the present study, we investigated the potential of a wood based NFC wound dressing in a clinical trial on burn patients. Previously, we have investigated NFC as a topical functionalized wound dressing that contributes to improve wound healing in mice. Wood based NFC wound dressing was tested in split-thickness skin graft donor site treatment for nine burn patients in clinical trials at Helsinki Burn Centre. NFC dressing was applied to split thickness skin graft donor sites. The dressing gradually dehydrated and attached to donor site during the first days. During the clinical trials, physical and mechanical properties of NFC wound dressing were optimized by changing its composition. From patient 5 forward, NFC dressing was compared to commercial lactocapromer dressing, Suprathel® (PMI Polymedics, Germany). Epithelialization of the NFC dressing-covered donor site was faster in comparison to Suprathel®. Healthy epithelialized skin was revealed under the detached NFC dressing. NFC dressing self-detached after 11-21days for patients 1-9, while Suprathel® self-detached after 16-28days for patients 5-9. In comparison studies with patients 5-9, NFC dressing self-detached on average 4days earlier compared with Suprathel®. Lower NFC content in the material was evaluated to influence the enhanced pliability of the dressing and attachment to the wound bed. No allergic reaction or inflammatory response to NFC was observed. NFC dressing did not cause more pain for patients than the traditional methods to treat the skin graft donor sites. Based on the preliminary clinical data, NFC dressing seems to be promising for skin graft donor site treatment since it is biocompatible, attaches easily to wound bed, and remains in place until donor site has renewed. It also detaches from the epithelialized skin by itself. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe
2012-12-15
Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).
NASA Astrophysics Data System (ADS)
Kampeerapappun, Piyaporn
In general, a dressing is used to protect and help heal wounds. There are several types of dressings on the market such as hydrocolloid, hydrogel, and medicated dressings. One technique for making a dressing is electrospinning, which is a very simple procedure used to produce fibers. Due to much smaller fiber-diameters than produced with the conventional technique, the fibers from electrospinning have unique properties: high porosity and high surface areas, which are advantageous for wound healing. In this research, the fibers were electrospun using polyurethane, TecophilicRTM or TecoflexRTM, with various additives. First, multilayer transdermal electrospun dressings, four and five-layers, were developed that allowed for the controlled release of nitric oxide (NO) from a NO2 -/ascorbic acid system encapsulated in polymer nanofibers. The amount of NO released from each wound dressing was investigated. Both the four and five-layer dressings were tested for morphology of fibers, water absorption, nitrite distribution, NO release profile after sterilization by gamma radiation, and stability. In the case of the four-layer transdermal dressing, the dressing was tested in diabetic, periodontal, and cutaneous leishmaniasis patients. Furthermore, the color change of dressing was investigated. TecophilicRTM was also spun with an antimicrobial agent, which was added to the TecophilicRTM solution to electrospin an antimicrobial dressing. The morphology of fibers was tested using an optical microscope and the water absorption, uniformity, and percent extraction of dressing were also determined. In addition, the efficiency of the antimicrobial agent in the dressing was determined according to SN 195920-1994 and ASTM 2149-01. Another NO-releasing dressing was developed employing the NO donor molecules, sodium salt of linear polyethylenimine NONOates (LPEINO-Na) and calcium salt of linear polyethylenimine NONOates (LPEINO-Ca), which were electrospun with TecophilicRTM. The NO release profiles for the LPEINO fibers were generated using a nitric oxide analyzer (NOA) and distribution of the particles in the dressing was examined. Moreover, the amount of NO released after patch storage for 1 and 2 months was determined.
... as much gauze or packing gauze. Removing the Old Dressing Follow these steps to remove your dressing: ... sterile gloves. Carefully remove the tape. Remove the old dressing. If it is sticking to your skin, ...
A prospective randomized clinical trial to evaluate methods of postoperative care of hypospadias.
McLorie, G; Joyner, B; Herz, D; McCallum, J; Bagli, D; Merguerian, P; Khoury, A
2001-05-01
Hypospadias repair is a common operation performed by pediatric urologists. Perhaps the greatest variable and source of controversy of postoperative care is the surgical dressing. We hypothesized that using no dressing would achieve surgically comparable results to those traditionally achieved by a postoperative dressing and it would also simplify postoperative parent delivered home care. Accordingly we designed a prospective randomized clinical trial to compare surgical outcome and postoperative care after hypospadias repair in boys with no dressing and those who received 1 of the 2 most common types of dressing. In a 12-month period 120 boys with an average age of 2.2 years underwent primary 1-stage hypospadias repair at a single center with 4 participating surgeons. Repair was performed in 60 boys with proximal and 60 with distal hypospadias on an outpatient basis. Ethics and Internal Review Board approval, and informed consent were obtained. Boys were then prospectively randomized to receive no dressing, an adhesive biomembrane dressing or a compressive wrap dressing. Comprehensive instructions on postoperative care were distributed to all families and a questionnaire was distributed to the parents at the initial followup. Surgical outcome was evaluated and questionnaire responses were analyzed. Fisher's exact test was done to test the significance of differences in surgical outcomes and questionnaire responses. A total of 117 boys completed the prospective randomized trial. Surgical staff withdrew 3 cases from randomized selection to place a dressing for postoperative hemostasis. We obtained 101 questionnaires for response analysis. The type or absence of the dressing did not correlate with the need for repeat procedures, urethrocutaneous fistula, or meatal stenosis or regression. Analysis revealed less narcotic use in the no dressing group and fewer telephone calls to the urology nurse, or on-call resident and/or fellow. These findings were statistically significant. In addition, there were more unscheduled visits to the urology clinic, emergency room or primary physician office by boys with than without a dressing. Furthermore, 29% of the parents were not psychologically prepared to remove the dressing and 12% were so reluctant that the dressing was removed at the urology outpatient clinic. The surgical outcome and rate of adverse events or complications were not compromised without a postoperative dressing. An absent dressing simplified postoperative ambulatory parent delivered home care. We recommend that dressings should be omitted from routine use after hypospadias repair.
Modulation Transfer Through Coherence and Its Application to Atomic Frequency Offset Locking
NASA Astrophysics Data System (ADS)
Jagatap, B. N.; Ray, Ayan; Kale, Y. B.; Singh, Niharika; Lawande, Q. V.
We discuss the process of modulation transfer in a coherently prepared three-level atomic medium and its prospective application to atomic frequency offset locking (AFOL). The issue of modulation transfer through coherence is treated in the framework of temporal evolution of dressed atomic system with externally superimposed deterministic flow. This dynamical description of the atom-field system offers distinctive advantage of using a single modulation source to dither passively the coherent phenomenon as probed by an independent laser system under pump-probe configuration. Modulation transfer is demonstrated experimentally using frequency modulation spectroscopy on a subnatural linewidth electromagnetically induced transparency (EIT) and a sub-Doppler linewidth Autler-Townes (AT) resonance in Doppler broadened alkali vapor medium, and AFOL is realized by stabilizing the probe laser on the first/third derivative signals. The stability of AFOL is discussed in terms of the frequency noise power spectral density and Allan variance. Analysis of AFOL schemes is carried out at the backdrop of closed loop active frequency control in a conventional master-slave scheme to point out the contrasting behavior of AFOL schemes based on EIT and AT resonances. This work adds up to the discussion on the subtle link between dressed state spectroscopy and AFOL, which is relevant for developing a master-slave type laser system in the domain of coherent photon-atom interaction.
Helium in chirped laser fields as a time-asymmetric atomic switch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaprálová-Žďánská, Petra Ruth, E-mail: kapralova@jh-inst.cas.cz; J. Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23 Prague 8; Moiseyev, Nimrod, E-mail: nimrod@tx.technion.ac.il
2014-07-07
Tuning the laser parameters exceptional points in the spectrum of the dressed laser helium atom are obtained. The weak linearly polarized laser couples the ground state and the doubly excited P-states of helium. We show here that for specific chirped laser pulses that encircle an exceptional point one can get the time-asymmetric phenomenon, where for a negative chirped laser pulse the ground state is transformed into the doubly excited auto-ionization state, while for a positive chirped laser pulse the resonance state is not populated and the neutral helium atoms remains in the ground state as the laser pulse is turnedmore » off. Moreover, we show that the results are very sensitive to the closed contour we choose. This time-asymmetric state exchange phenomenon can be considered as a time-asymmetric atomic switch. The optimal time-asymmetric switch is obtained when the closed loop that encircles the exceptional point is large, while for the smallest loops, the time-asymmetric phenomenon does not take place. A systematic way for studying the effect of the chosen closed contour that encircles the exceptional point on the time-asymmetric phenomenon is proposed.« less
Evaluation of a foam dressing for acute and chronic wound exudate management.
Bullough, Lindsay; Johnson, Sue; Forder, Rebecca
2015-09-01
This article discusses the use of a foam dressing for exudate management in both chronic and acute wounds, such as surgical wounds, pressure ulcers, diabetic ulcers, trauma wounds, and leg ulcers. The primary objective of the study was to observe patients' wound progression in terms of wound size and the condition of the wound bed, when using this foam dressing as either a primary or secondary dressing. The outcome of the evaluation demonstrated that ActivHeal Foam Contact dressing effectively managed exudate. It was also observed that the dressing can assist in autolysis and support improvements in peri-wound status. Choosing an appropriate dressing to manage a wound is essential. Clinicians working in the NHS are under pressure to deliver good-quality clinical outcomes, and the ActivHeal Foam Contact dressing supports this outcome.
Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-05-01
Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). This laboratory study evaluated the DRESS prototype's capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing-typical issues that challenge a PWD and their caregivers. A set of expected detections for correct dressing was prepared via video analysis of all participants' dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype's ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype's reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. ©Winslow Burleson, Cecil Lozano, Vijay Ravishankar, Jisoo Lee, Diane Mahoney. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.05.2018.
Evaluation of dressings used with local anaesthetic cream and for peripheral venous cannulation.
Needham, Rowan; Strehle, Eugen-Matthias
2008-10-01
To compare four polyurethane dressings manufactured by two different companies for use in children. Seventy-eight dressings were applied to secure either local anaesthetic creams (n = 62) or intravenous cannulae (n = 16). Each dressing was evaluated for ease of application, security and ease of removal, using a simple scoring system. 84 per cent of Opsite flexigrid and 90 per cent of Tegaderm local anaesthetic cream dressings were rated as easy or very easy to apply. Opsite flexigrid was felt to be more secure, whereas Tegaderm was easier to remove. The Tegaderm cannula dressing was easier to apply than the iv3000 dressing. There was little difference between the two brands, including costs.
ERIC Educational Resources Information Center
Griffiths, Noola K.
2010-01-01
This study investigates the effects of concert dress and physical appearance on perceptions of female classical soloists' musical abilities over a range of genres. Four female violinists were recorded playing three pieces, in four styles of dress of varying formality. Each combination of performer, piece and dress was recorded twice, once as the…
Use of wound dressings with soft silicone adhesive technology.
Morris, Clare; Emsley, Paulene; Marland, Elizabeth; Meuleneire, Frans; White, Richard
2009-04-01
To evaluate how pain, during and in-between dressing changes, is affected by the introduction of Mepilex Border Lite, a wound dressing manufactured by Mölnlycke Health Care using Safetac soft silicone adhesive technology, to the treatment of different types of paediatric wounds/skin injuries. Wounds/skin injuries that met the criteria for inclusion in the study were dressed with Mepilex Border Lite. Patients were followed for six weeks or until their wounds/skin injuries had healed, whichever occurred earlier. At each dressing change, pain severity before and during dressing removal was rated by the patient and the investigator on a scale from zero (no pain at all) to ten (worst pain ever). Other variables measured included: signs of trauma to wound/skin injury and surrounding skin, the proportion of viable/non-viable tissue, the quantity and appearance of exudate, odour, and clinical signs of infection. At the final dressing change, patients and investigators completed questionnaires to rate the dressing performance. Mean pain severity scores were significantly lower (p < or = 0.003) at the first dressing change than at baseline. Over 99.5 per cent of the Mepilex Border Lite dressing changes were reported to be atraumatic and more than half of the wounds healed within the study period. Conformability, ease of use, ease of removal, patient comfort, and overall experience with the dressing were rated as 'good' to 'very good' at the vast majority of final visit evaluations. This study provides further evidence of the ability of dressings with Safetac soft silicone adhesive technology to minimise trauma and pain and demonstrates the ability of Mepilex Border Lite to overcome the clinical challenges associated with the use of dressings on the wounds/skin injuries of paediatric patients.
Zehrer, Cindy L; Holm, David; Solfest, Staci E; Walters, Shelley-Ann
2014-12-01
This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Napavichayanun, Supamas; Yamdech, Rungnapha; Aramwit, Pornanong
2016-03-01
In our previous work, we have attempted to develop a novel bacterial nanocellulose wound dressing which composed of both polyhexamethylene biguanide (PHMB) as an antimicrobial agent and sericin as an accelerative wound healing component. The loading sequence and concentration of PHMB and sericin were optimized to provide the wound dressing with the most effective antimicrobial activity and enhanced collagen production. In this study, further in vitro, in vivo, and clinical studies of this novel wound dressing were performed to evaluate its safety, efficacy, and applicability. For the in vitro cytotoxic test with L929 mouse fibroblast cells, our novel dressing was not toxic to the cells and also promoted cell migration as good as the commercially available dressing, possibly due to the component of sericin released. When implanted subcutaneously in rats, the lower inflammation response was observed for the novel dressing implanted, comparing to the commercially available dressing. This might be that the antimicrobial PHMB component of the novel dressing played a role to reduce infection and inflammation reaction. The clinical trial patch test was performed on the normal skin of healthy volunteers to evaluate the irritation effect of the dressing. Our novel dressing did not irritate the skin of any volunteers, as characterized by the normal levels of erythema and melanin and the absence of edema, papule, vesicle, and bullae. Then, the novel dressing was applied for the treatment of full-thickness wounds in rats. The wounds treated with our novel dressing showed significantly lower percentage of wound size and higher extent of collagen formation mainly due to the activity of sericin. We concluded that our novel bacterial nanocellulose incorporating PHMB and sericin was a safe and efficient wound dressing material for further investigation in the wound healing efficacy in clinic.
Cost of dressings for prevention of sacral pressure ulcers.
Inoue, Kelly Cristina; Matsuda, Laura Misue
2016-01-01
to identify costs of dressings to prevent sacral pressure ulcers in an adult intensive care unit in Paraná, Brazil. secondary analysis study with 25 patients admitted between October 2013 and March 2014, using transparent polyurethane film (n=15) or hydrocolloid dressing (n=10) on the sacral region. The cost of each intervention was based on the unit amount used in each type of dressing, and its purchase price (transparent film = R$15.80, hydrocolloid dressing = R$68.00). the mean cost/patient was R$23.17 for use of transparent film and R$190.40 for use of hydrocolloid dressing. The main reason for changing the dressing was detachment. the transparent film was the most economically advantageous alternative to prevent sacral pressure ulcers in critical care patients. However, additional studies should be carried out including assessment of the effectiveness of both dressings.
Genuino, Glenn Angelo S; Baluyut-Angeles, Kathrina Victoria; Espiritu, Andre Paolo T; Lapitan, Marie Carmela M; Buckley, Brian S
2014-11-01
Non-extensive superficial partial thickness burns constitute a major proportion of burns. Conventional treatment involves regular changing of absorptive dressings including the application of a topical antimicrobial, commonly silver sulfadiazine. A systematic review has found insufficient evidence to support or refute such antimicrobial prophylaxis. Another review compared silver sulfadiazine dressings with other occlusive and non-antimicrobial dressings and found insufficient evidence to guide practice. Other research has suggested that dressings with petrolatum gel are as effective as silver sulfadiazine. Single-center, randomized, controlled parallel group trial comparing conventional silver sulfadiazine dressings with treatment with petrolatum gel alone. Consenting adults 18-45 years old with superficial partial thickness burns≤10% total body surface area seen within 24h of the injury were randomized to daily dressing either with petrolatum gel without top dressings or conventional silver sulfadiazine treatment with gauze dressings. Primary outcomes were blinded assessment of time to complete re-epithelialization, wound infection or allergic contact dermatitis. Secondary outcomes included assessment of ease, time and pain of dressing changes. 26 patients were randomized to petrolatum and 24 to silver sulfadiazine dressings. Follow up data available for 19 in each group. Mean time to re-epithelialization was 6.2 days (SD 2.8) in the petrolatum group and 7.8 days (SD 2.1) in the silver sulfadiazine group (p=0.050). No wound infection or dermatitis was observed in either group. Scores for adherence to wound, ease of dressing removal and time required to change dressings were significantly better in the petrolatum treatment arm (p<0.01). Petrolatum gel without top dressings may be at least as effective as silver sulfadiazine gauze dressings with regard to time to re-epithelialization, and incidence of infection and allergic contact dermatitis. Petrolatum gel appears to be an effective, affordable and widely available alternative in the treatment of minor superficial partial thickness burns in adults. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Kent, Dea J
2010-01-01
I compared the effects of a just-in-time educational intervention (educational materials for dressing application attached to the manufacturer's dressing package) to traditional wound care education on reported confidence and dressing application in a simulated model. Nurses from a variety of backgrounds were recruited for this study. The nurses possessed all levels of education ranging from licensed practical nurse to master of science in nursing. Both novice and seasoned nurses were included, with no stipulations regarding years of nursing experience. Exclusion criteria included nurses who spent less than 50% of their time in direct patient care and nurses with advanced wound care training and/or certification (CWOCN, CWON). Study settings included community-based acute care facilities, critical access hospitals, long-term care facilities, long-term acute care facilities, and home care agencies. No level 1 trauma centers were included in the study for geographical reasons. Participants were randomly allocated to control or intervention groups. Each participant completed the Kent Dressing Confidence Assessment tool. Subjects were then asked to apply the dressing to a wound model under the observation of either the principal investigator or a trained observer, who scored the accuracy of dressing application according to established criteria. None of the 139 nurses who received traditional dressing packaging were able to apply the dressing to a wound model correctly. In contrast, 88% of the nurses who received the package with the educational guide attached to it were able to apply the dressing to a wound model correctly (χ2 = 107.22, df = 1, P = .0001). Nurses who received the dressing package with the attached educational guide agreed that this feature gave them confidence to correctly apply the dressing (88%), while no nurse agreed that the traditional package gave him or her the confidence to apply the dressing correctly (χ2 = 147.47, df = 4, P < .0001). A just-in-time education intervention improved nurses' confidence when applying an unfamiliar dressing and accuracy of application when applying the dressing to a simulated model compared to traditional wound care education.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations.
Wu, Stephanie; Applewhite, Andrew J; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-11-01
Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. A 2-day panel meeting convened in February 2017. Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations
Wu, Stephanie; Applewhite, Andrew J.; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-01-01
ABSTRACT OBJECTIVE: Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. DESIGN: A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. SETTING: A 2-day panel meeting convened in February 2017. PARTICIPANTS: Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. RESULTS: The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. CONCLUSIONS: An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed. PMID:29049055
Economics of pressure-ulcer care: review of the literature on modern versus traditional dressings.
San Miguel, L; Torra i Bou, J E; Verdú Soriano, J
2007-01-01
Published evidence suggests that some of the benefits of modern dressings--longer wear times and less frequent dressing changes--make them more cost-effective than traditional gauze dressings in pressure ulcer management.
Watson, Denis; Bergquist, Stephen; Nicholson, Julie; Norrie, David H
2017-06-28
While Manuka honey in vitro is strongly antimicrobial, there have been, to the best of the authors' knowledge, no studies showing that dressings impregnated with Manuka honey can kill organisms in the dressing itself. The investigators used the American Association of Textile Chemists and Colorists' 100 test methodology to compare honey-impregnated dressings with control dressings (without honey) on the ability to kill common wound pathogens. Organisms were chosen after a review of the causal organisms found in actual wound infections over a 12-month period in a busy outpatient wound clinic. Even when the dressings were challenged daily with further inoculated organisms, > 5-log reductions were routinely noted across a range of pathogens, including multiple drug-resistant species using dressings containing Manuka honey relative to the control. The results presented herein show that when well-characterized medical-grade Manuka honey is used in dressings (ie, a minimum of 400 mg methylglyoxal/kg) these dressings can comprehensively kill common wound pathogens associated with infected wounds.
Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-01-01
Background Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. Objective In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). Methods This laboratory study evaluated the DRESS prototype’s capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing—typical issues that challenge a PWD and their caregivers. Results A set of expected detections for correct dressing was prepared via video analysis of all participants’ dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype’s ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype’s reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. Conclusions This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. PMID:29716885
Effects of adhesive dressings on stratum corneum conductance.
Cavallini, Maurizio; Gazzola, Riccardo; Vaienti, Luca
2012-05-01
Stratum corneum is a fundamental layer of epidermis. It acts as a barrier, with antimicrobial features, regulating skin permeability and integrity as well. Adhesive dressings and their removal could alter this layer, affecting cutaneous water balance and lipid composition of stratum corneum. These changes could be monitored by measurement of cutaneous hydration. Ninety-two patients affected by wounds dressed with adhesive tapes or plasters have been studied. Measurement of skin conductance under tape/plaster and in the surrounding healthy skin, immediately after removal of dressing has been performed. Dressing age, wound localization, and characteristics were also considered. Adhesive dressings alter significantly stratum corneum conductance. Although healthy skin hydration has significant variations throughout the body, cutaneous conductance under adhesive dressing in different areas displays no significative changes. Moreover, the increase in hydration due to adhesive tapes/plasters showed no association with wound dehiscence. Adhesive dressings cause a significative increase in stratum corneum conductance, acting as a barrier to apocrine secretions. Although different hydration levels have been observed in healthy skin throughout the body, no difference exists under adhesive dressing among different regions, suggesting no contraindications in their employment throughout the body. Increase in cutaneous hydration showed no correlations with wound dehiscence, thus confirming safety and practicality of these dressings. © 2011 John Wiley & Sons A/S.
Percy, Dean B; Haddock, Candace; Ma, Vivian; Nowak, Amie; Panczuk, Julia; Butterworth, Sonia
2018-05-01
The purpose of this study was to describe outcomes and resource utilization in patients treated with twice-weekly silver impregnated (SI) nanocrystalline dressings for initial non-operative management of giant omphalocele (GO). A retrospective review of patients with GO treated with SI dressings was undertaken. Clinical parameters, cost, and complications were recorded. Five patients with GO were treated with SI dressings between 2014 and 2016. Clinical characteristic (mean ± SD) included gestational age 36 ± 4 weeks, birth weight 2.6 ± 0.63 kg, GO size 10.2 ± 4.7 cm, ventilator days 7.5 ± 8.7 d, days in NICU 41 ± 20 d, days to full feeds, 30 ± 15 d, and LOS 62 ± 41 d. The average in-hospital cost of SI dressings was $110 CAD/week. This is comparable to daily silver sulfadiazine dressings ($109CAD/week) which were used historically. All patients were discharged with once- or twice-weekly dressing changes. No ruptures occurred. There was one mortality secondary to pulmonary sepsis. For initial non-operative management of GO, twice weekly SI nanocrystalline dressings is safe and effective. Use of SI dressings results in decreased handling of infants, reduced physician and nursing resource utilization, and favourable outcomes. IV (Retrospective Case Series). Copyright © 2018. Published by Elsevier Inc.
Hua, Yun; Qiu, Rong; Yao, Wen-Yan; Zhang, Qin; Chen, Xiao-Li
2015-10-01
It has been demonstrated that patients with chronic wounds experience the most pain during dressing changes. Currently, researchers focus mostly on analgesics and appropriate dressing materials to relieve pain during dressing changes of chronic wounds. However, the effect of nonpharmacologic interventions, such as virtual reality distraction, on pain management during dressing changes of pediatric chronic wounds remains poorly understood. To investigate the effect of virtual reality distraction on alleviating pain during dressing changes in children with chronic wounds on their lower limbs. A prospective randomized study. A pediatric center in a tertiary hospital. Sixty-five children, aged from 4 to 16 years, with chronic wounds on their lower limbs. Pain and anxiety scores during dressing changes were recorded by using the Wong-Baker Faces picture scale, visual analogue scale, and pain behavior scale, as well as physiological measurements including pulse rate and oxygen saturation. Time length of dressing change was recorded. Virtual reality distraction significantly relieved pain and anxiety scores during dressing changes and reduced the time length for dressing changes as compared to standard distraction methods. The use of virtual reality as a distraction tool in a pediatric ward offered superior pain reduction to children as compared to standard distractions. This device can potentially improve clinical efficiency by reducing length time for dressing changes. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
Protein matrices for wound dressings =
NASA Astrophysics Data System (ADS)
Vasconcelos, Andreia Joana Costa
Fibrous proteins such as silk fibroin (SF), keratin (K) and elastin (EL) are able to mimic the extracellular matrix (ECM) that allows their recognition under physiological conditions. The impressive mechanical properties, the environmental stability, in combination with their biocompatibility and control of morphology, provide an important basis to use these proteins in biomedical applications like protein-based wound dressings. Along time the concept of wound dressings has changed from the traditional dressings such as honey or natural fibres, used just to protect the wound from external factors, to the interactive dressings of the present. Wounds can be classified in acute that heal in the expected time frame, and chronic, which fail to heal because the orderly sequence of events is disrupted at one or more stages of the healing process. Moreover, chronic wound exudates contain high levels of tissue destructive proteolytic enzymes such as human neutrophil elastase (HNE) that need to be controlled for a proper healing. The aim of this work is to exploit the self-assemble properties of silk fibroin, keratin and elastin for the development of new protein materials to be used as wound dressings: i) evaluation of the blending effect on the physical and chemical properties of the materials; ii) development of materials with different morphologies; iii) assessment of the cytocompatibility of the protein matrices; iv) ultimately, study the ability of the developed protein matrices as wound dressings through the use of human chronic wound exudate; v) use of innovative short peptide sequences that allow to target the control of high levels of HNE found on chronic wounds. Chapter III reports the preparation of silk fibroin/keratin (SF/K) blend films by solvent casting evaporation. Two solvent systems, aqueous and acidic, were used for the preparation of films from fibroin and keratin extracted from the respective silk and wool fibres. The effect of solvent system used was studied by evaluating the physical-chemical properties of the resulting films. It was shown that SF and K are able to establish intermolecular interactions when mixed and, that the mechanical properties and the biological degradation can be tuned by the blend composition. In Chapter IV, SF/K films were further used to serve as a platform for the release of HNE inhibitors peptides. Bowman-Birk inhibitor (BBI) based peptide was incorporated onto the SF/K films that were consequently incubated with porcine pancreatic elastase (PPE) as a model for HNE, to monitor the decrease in activity. The results indicated that swelling properties, degradation and release rates are dependent on the amount of keratin present in the blend. Furthermore, no cytotoxicity was observed in the presence of mouse fibroblasts, which makes these SF/K films suitable candidates for interactive wound dressings with a specific goal - controlling high levels of HNE. The next step of the work, Chapter V, reports for the first time blends of silk fibroin with elastin (SF/EL) for the production of scaffolds. These were prepared by lyophilization technique and crosslinked with a natural and low toxic agent, genipin. The crosslink allows the control of the scaffolds morphology, such as pore size and porosity, which in turns, modulates the ex vivo degradation rates, by a human chronic wound exudate, and the release rates of model compounds. In addition, no cytotoxicity was observed for SF/EL samples, with and without genipin, by human skin fibroblasts. Thus, the high porosity observed for SF/EL scaffolds, allowing the growth and cellular attachment, together with their biocompatibility provide fitting characteristics for wound dressings. Chapter VI, describes the design of two elastase inhibitors peptides based on the reactive site-loop of the BBI protein in order to control the high levels HNE. To a known peptide sequence, modifications were made at both N- and C-terminal. Inhibition kinetics analysis indicated that these peptides are competitive inhibitors for HNE and PPE and, that the inhibitory potency can be regulated by the introduced modifications. Additionally, these peptides showed no toxicity with human skin fibroblasts and, were also effective in reducing the HNE activity found in a human chronic wound exudate, which allow them to be applied to those wounds. The motivation for this thesis was to combine the excellent properties of silk fibroin with other proteins. Blending allows modulating the physical-chemical properties of the resulting materials such as mechanical strength, swelling, morphology, degradation and release rates. Silk fibroin is widely characterized in the literature for the production of biomaterials, but this work is the first that successfully evaluates the blends silk fibroin/keratin (SF/K) and silk fibroin/elastin (SF/EL) for their application as wound dressings.
An Inexpensive Bismuth-Petrolatum Dressing for Treatment of Burns
Chattopadhyay, Arhana; Chang, Kathleen; Nguyen, Khoa; Galvez, Michael G.; Legrand, Anais; Davis, Christopher; McGoldrick, Rory; Long, Chao; Pham, Hung
2016-01-01
Background: Xeroform remains the current standard for treating superficial partial-thickness burns but can be prohibitively expensive in developing countries with prevalent burn injuries. This study (1) describes the production of an alternative low-cost dressing and (2) compares the alternative dressing and Xeroform using the metrics of cost-effectiveness, antimicrobial activity, and biocompatibility in vitro, and wound healing in vivo. Methods: To produce the alternative dressing, 3% bismuth tribromophenate powder was combined with petroleum jelly by hand and applied to Kerlix gauze. To assess cost-effectiveness, the unit costs of Xeroform and components of the alternative dressing were compared. To assess antimicrobial properties, the dressings were placed on agar plated with Escherichia coli and the Kirby-Bauer assay performed. To assess biocompatibility, the dressings were incubated with human dermal fibroblasts and cells stained with methylene blue. To assess in vivo wound healing, dressings were applied to excisional wounds on rats and the rate of re-epithelialization calculated. Results: The alternative dressing costs 34% of the least expensive brand of Xeroform. Antimicrobial assays showed that both dressings had similar bacteriostatic effects. Biocompatibility assays showed that there was no statistical difference (P < 0.05) in the cytotoxicity of Xeroform, alternative dressing, and Kerlix gauze. Finally, the in vivo healing model showed no statistical difference (P < 0.05) in mean re-epithelialization time between Xeroform (13.0 ± 1.6 days) and alternative dressing (13.5 ± 1.0 days). Conclusions: Xeroform is biocompatible, reduces infection, and enhances healing of burn wounds by preventing desiccation and mechanical trauma. Handmade petrolatum gauze may be a low-cost replacement for Xeroform. Future studies will focus on clinical trials in burn units. PMID:27482485
Nherera, Leo; Trueman, Paul; Roberts, Christopher; Berg, Leena
2018-02-23
Burn injury is a common type of traumatic injury that causes considerable morbidity and mortality, resulting in about 30,000 admissions annually in specialist burn centers and costing around $1 billion per year in the United States. One percent silver sulfadiazine has been utilized widely in the management of burns and newer silver dressings are on the market, including nanocrystalline silver dressings, silver-impregnated hydrofiber dressings, and silver-impregnated foam dressings. This study sought to determine the cost effectiveness of the newer silver dressings using clinical data from an indirect treatment comparison using silver sulfadiazine as the baseline. A decision analytic model was developed from a US payer's perspective for burn patients with a total body surface area of < 20%. Outcomes were length of stay, infections and incidence of surgical procedures, quality adjusted life years (QALYs), and cost. The meta-analysis reported a statistically significant reduction in length of hospital stay and clinically important reductions in infections and incidence of surgical procedures in favor of the silver barrier dressing compared with other silver dressings. The estimated QALYs were 0.970 versus 0.969 versus 0.969 and mean cost per patient was $15,892, $23,799, and $24,269 for the nanocrystalline silver dressing, silver-impregnated hydrofiber dressing, and silver-impregnated foam dressing, respectively. The analysis showed the nanocrystalline silver dressing to be a dominant strategy (less costly with better outcomes). These findings were robust to a range of sensitivity analyses. According to data from an indirect treatment comparison, this analysis suggests that nanocrystalline silver dressing is the most cost-effective silver delivery system. Prospective head-to-head research on the costs and outcomes of these silver delivery systems in this patient population is necessary to validate the results of this economic evaluation.
Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie
2013-11-25
In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.
Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.
Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C
2013-07-01
Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.
Klode, J; Schöttler, L; Stoffels, I; Körber, A; Schadendorf, D; Dissemond, J
2011-08-01
In the process of chronic wound care, adhesive wound dressings may cause pain and injury in the wound environment during dressing changes. At present, no standardized test procedures are available for the investigation of adhesion of wound dressings. Therefore, our study aimed to test the adhesion of different wound dressings on steel as well as on healthy skin. Within an open, comparative study, the adhesive areas of 56 wound dressings were investigated. The adhesives were categorized into acrylate (n = 23), silicone (n = 9), hydrocolloid (n = 17) and polyurethane groups (n = 7). Using an especially modified testing machine, the adhesion of the wound dressings was measured on steel as well as on the skin of healthy study participants, in compliance with the European EN 1939:2003 standard. The energy required to remove the wound dressings from human skin, was measured in Newton (N) and the following median values were obtained: hydrocolloid (2.25 N) > acrylate (1.14 N) > polyurethane (0.9 N) > silicone (0.7 N). The subjective pain intensity during the removal of the wound dressings was recorded using the visual analogue scale (VAS) with values ranging from 0 to 10. For hydrocolloid, it was 6.8, for acrylate 4.9, for polyurethane 3.1 and for silicone 2.5 points VAS. In comparison with human skin, the adhesion of wound dressings was significantly higher on steel (P < 0.0001), but was different for the different groups of wound dressings. Moreover, there was a statistically significant correlation between the adhesion and pain intensity (correlation coefficient 0.806; P = 0.01). The knowledge about the widely differing adhesion properties of different wound dressings on the skin of patients should nowadays be considered during the individual selection of the applied products. Based on these data, different types of wound dressings could be developed, guaranteeing a good adhesion and a low traumatic risk when removed. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.
Renda, Francesca; Landoni, Giovanni; Bertini Malgarini, Renato; Assisi, Alessandro; Azzolini, Maria Luisa; Mucchetti, Marta; Pimpinella, Giuseppe; Pani, Luca
2015-12-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare, severe and potentially fatal cutaneous adverse drug reaction (the mortality rate is up to 10 %) associated with numerous and apparently heterogeneous drugs. The aetiology is unknown. To report Italian cases of DRESS over a 10-year period. We searched the National Pharmacovigilance Network (NPN) for the term 'drug reaction with eosinophilia and systemic symptoms' from 1 January 2004 to 1 January 2014, to identify all reports of DRESS. Each case was checked to avoid duplication. In the NPN, we identified 91 serious cases of DRESS: 68 were spontaneous, still-unpublished reports, while 23 additional cases were derived from screening of the scientific literature, performed by marketing authorization holders. Notably, the single common element linking all cases of DRESS was intake of a drug containing an aromatic ring. Thanks to the largest national DRESS case series ever reported, we were able to hypothesize, for the first time, that there is an association between use of drugs containing an aromatic ring in their chemical structure and DRESS. This might aid understanding of the aetiology of DRESS and facilitate diagnosis.
NASA Astrophysics Data System (ADS)
Wei, Qilin; Xu, Feiyang; Xu, Xingjian; Geng, Xue; Ye, Lin; Zhang, Aiying; Feng, Zengguo
2016-06-01
The non-woven wound dressing with core-shell structured fibers was prepared by coaxial electrospinning. The polycaprolactone (PCL) was electrospun as the fiber's core to provide mechanical strength whereas collagen was fabricated into the shell in order to utilize its good biocompatibility. Simultaneously, the silver nanoparticles (Ag-NPs) as anti-bacterial agent were loaded in the shell whereas the vitamin A palmitate (VA) as healing-promoting drug was encapsulated in the core. Resulting from the fiber's core-shell structure, the VA released from the core and Ag-NPs present in the shell can endow the dressing both heal-promoting and anti-bacteria ability simultaneously, which can greatly enhance the dressing's clinical therapeutic effect. The dressing can maintain high swelling ratio of 190% for 3 d indicating its potential application as wet dressing. Furthermore, the dressing's anti-bacteria ability against Staphylococcus aureus was proved by in vitro anti-bacteria test. The in vitro drug release test showed the sustainable release of VA within 72 h, while the cell attachment showed L929 cells can well attach on the dressing indicating its good biocompatibility. In conclusion, the fabricated nanofibrous dressing possesses multiple functions to benefit wound healing and shows promising potential for clinical application.
Imran, Muhammad; Hussain, Muhammad Barkaat; Baig, Mukhtiar
2015-10-01
To investigate the effect of Beri-honey-impregnated dressing on diabetic foot ulcer and compare it with normal saline dressing. A randomized, controlled trial. Sughra Shafi Medical Complex, Narowal, Pakistan and Bhatti International Trust (BIT) Hospital, Affiliated with Central Park Medical College, Lahore, from February 2006 to February 2010. Patients with Wagner's grade 1 and 2 ulcers were enrolled. Those patients were divided in two groups; group A (n=179) treated with honey dressing and group B (n=169) treated with normal saline dressing. Outcome measures were calculated in terms of proportion of wounds completely healed (primary outcome), wound healing time, and deterioration of wounds. Patients were followed-up for a maximum of 120 days. One hundred and thirty six wounds (75.97%) out of 179 were completely healed with honey dressing and 97 (57.39%) out of 169 wtih saline dressing (p=0.001). The median wound healing time was 18.00 (6 - 120) days (Median with IQR) in group A and 29.00 (7 - 120) days (Median with IQR) in group B (p < 0.001). The present results showed that honey is an effective dressing agent instead of conventional dressings, in treating patients of diabetic foot ulcer.
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false French dressing. 169.115 Section 169.115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
ERIC Educational Resources Information Center
Dulin, Charles Dewitt
2016-01-01
The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…
Verbelen, Jozef; Hoeksema, Henk; Heyneman, Alexander; Pirayesh, Ali; Monstrey, Stan
2014-05-01
Studies comparing contemporary silver dressings in burns are scarce. In a prospective, randomized, controlled study, counting 50 patients/research group, we compared two frequently used silver dressings, Acticoat™ and Aquacel(®) Ag, in the management of partial thickness burns with a predicted healing time between 7 and 21 days as assessed by laser Doppler imaging between 48 and 72h after burn. Variables investigated were related to baseline research group characteristics, wound healing, bacteriology, economics, nurse, and patient experience. Both research groups were comparably composed taking into account gender, age and burn characteristics. Similar results were obtained as to healing time and bacterial control with both silver dressings. A statistically significant difference in favor of the Aquacel(®) Ag dressing was found for average ease of use (p<0.001), average ease of application (p=0.001), patient pain (p<0.001), patient comfort with the dressing (p=0.017), silver staining (p<0.001), and cost effectiveness (p<0.001). Both silver dressings resulted in comparable healing times and bacterial control but the Aquacel(®) Ag dressing significantly increased comfort for patients as well as nurses and was significantly more cost-effective than the Acticoat™ dressing for the given indication. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Davis, Stephen C; Li, Jie; Gil, Joel; Valdes, Jose; Solis, Michael; Higa, Alex; Bowler, Philip
2018-06-11
Topical antimicrobials are widely used to control wound bioburden and facilitate wound healing; however, the fine balance between antimicrobial efficacy and non-toxicity must be achieved. This study evaluated whether an anti-biofilm silver-containing wound dressing interfered with the normal healing process in non-contaminated deep partial thickness wounds. In an in-vivo porcine wound model using 2 pigs, 96 wounds were randomly assigned to 1 of 3 dressing groups: anti-biofilm silver Hydrofiber dressing (test), silver Hydrofiber dressing (control), or polyurethane film dressing (control). Wounds were investigated for 8 days, and wound biopsies (n = 4) were taken from each dressing group, per animal, on days 2, 4, 6, and 8 after wounding and evaluated using light microscopy. No statistically significant differences were observed in the rate of reepithelialisation, white blood cell infiltration, angiogenesis, or granulation tissue formation following application of the anti-biofilm silver Hydrofiber dressing versus the 2 control dressings. Overall, epithelial thickness was similar between groups. Some differences in infiltration of specific cell types were observed between groups. There were no signs of tissue necrosis, fibrosis, or fatty infiltration in any group. An anti-biofilm silver Hydrofiber wound dressing did not cause any notable interference with normal healing processes. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Payne, Wyatt G; Posnett, John; Alvarez, Oscar; Brown-Etris, Marie; Jameson, Gayle; Wolcott, Randall; Dharma, Hussein; Hartwell, Samantha; Ochs, Diane
2009-02-01
Modern dressings such as hydrocolloids, gels, and foams are typically more expensive than traditional dressings such as gauze. However, if modern dressings require fewer changes, the overall cost of treatment may be lower despite the higher initial purchase price. If healing rates are comparable or better, modern dressings also may be cost-effective. A 4-week, prospective, randomized clinical trial to assess differences in treatment costs and cost-effectiveness between a modern foam dressing and saline-soaked gauze was conducted among 36 patients (22 men, 14 women, mean age 72.8 years) with a Stage II pressure ulcer (mean duration 35 weeks) at five centers in the United States. Participants were randomized to treatment with a self-adhesive polyurethane foam (n = 20) or saline-soaked gauze dressing (n = 16). No difference in time to wound closure was observed (P = 0.817). Patients in the foam group had less frequent dressing changes (P <0.001). Total cost over the study period was lower by $466 per patient (P = 0.055) and spending on dressings was lower by $92 per patient in the foam group (P = 0.025). Cost per ulcer healed was lower by $1,517 and cost per ulcer-free day was lower by $80 for patients in the foam group. On the evidence of this study, the foam dressing is a more cost-effective treatment than saline-soaked gauze for the treatment of Stage II pressure ulcers.
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
Rationale for Student Dress Codes: A Review of School Handbooks
ERIC Educational Resources Information Center
Freeburg, Elizabeth W.; Workman, Jane E.; Lentz-Hees, Elizabeth S.
2004-01-01
Through dress codes, schools establish rules governing student appearance. This study examined stated rationales for dress and appearance codes in secondary school handbooks; 182 handbooks were received. Of 150 handbooks containing a rationale, 117 related dress and appearance regulations to students' right to a non-disruptive educational…
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
Colloidal silver-based nanogel as nonocclusive dressing for multiple superficial pellet wounds.
Dharmshaktu, Ganesh Singh; Singhal, Aanshu; Pangtey, Tanuja
2016-01-01
A good dressing is mandatory to an uncomplicated wound healing, especially when foreign particles contaminate the wound. Various forms of dressing preparations are available for use and differ in chemical composition and efficacy. Silver has been a known agent with good antimicrobial and healing properties and recent times has seen an upsurge in various silver-based dressing supplements. We describe our report of use and efficacy of a silver nanoparticle- based gel dressing in the healing of multiple superficial firearm pellet wounds.
Self adhesive dressing pouch for the protection of catheters.
de la Cruz Martínez, Maria Teresa; Hernández, María José
2002-01-01
This paper is about a new model of dressing, used for the protection of all types of temporary and permanent catheters. Those who developed this dressing realised the practical difficulties during the placement and removal of traditional dressings, used in haemodialysis units. They also realised that it this was unpleasant for the patients, and there was a risk to the catheters when removing the dressings because of the use of scissors and other cutting instruments. This new dressing solves these previously mentioned problems and at the same time contributes to the comfort of the patients. The model has been registered as a standard using model, and therefore it is protected by law and its copyright (Intellectual Property).
Tunable electromagnetically induced transparency and absorption with dressed superconducting qubits
NASA Astrophysics Data System (ADS)
Ian, Hou; Liu, Yu-Xi; Nori, Franco
2010-06-01
Electromagnetically induced transparency and absorption (EIT and EIA) are usually demonstrated using three-level atomic systems. In contrast to the usual case, we theoretically study the EIT and EIA in an equivalent three-level system: a superconducting two-level system (qubit) dressed by a single-mode cavity field. In this equivalent system, we find that both the EIT and the EIA can be tuned by controlling the level-spacing of the superconducting qubit and hence controlling the dressed system. This tunability is due to the dressed relaxation and dephasing rates which vary parametrically with the level-spacing of the original qubit and thus affect the transition properties of the dressed qubit and the susceptibility. These dressed relaxation and dephasing rates characterize the reaction of the dressed qubit to an incident probe field. Using recent experimental data on superconducting qubits (charge, phase, and flux qubits) to demonstrate our approach, we show the possibility of experimentally realizing this proposal.
Childress, Beverly B; Berceli, Scott A; Nelson, Peter R; Lee, W Anthony; Ozaki, C Keith
2007-09-01
Surgical wounds for lower extremity revascularization are prone to infection and dehiscence. Acticoat Absorbent, an antimicrobial dressing, offers sustained release of ionic silver. We hypothesized that immediate application of Acticoat as a postoperative dressing would reduce wound complications in patients undergoing leg revascularization. All infrainguinal revascularization cases involving leg incisions at a single Veterans Administration Medical Center were identified from July 1, 2002, to September 30, 2005. The control group received conventional dressings, while the treatment group received an Acticoat dressing. Wound complication rates were captured via National Surgical Quality Improvement Program data. Patient characteristics and procedure distributions were similar between groups. The wound complication rate fell 64% with utilization of the Acticoat-based dressing (control 14% [17/118], treatment 5% [7/130]; P = 0.016). An Acticoat-based dressing system offers a potentially useful, cost-effective adjunct to reduce open surgical leg revascularization wound complications.
School Dress Codes v. The First Amendment: Ganging up on Student Attire.
ERIC Educational Resources Information Center
Jahn, Karon L.
Do school dress codes written with the specific purpose of limiting individual dress preferences, including dress associated with gangs, infringe on speech freedoms granted by the First Amendment of the U.S. Constitution? Although the Supreme Court has extended its protection of political speech to nonverbal acts of communication, it has…
Dressing of Cognitively Impaired Nursing Home Residents: Description and Analysis
ERIC Educational Resources Information Center
Cohen-Mansfield, Jiska; Creedon, Michael A.; Malone, Thomas; Parpura-Gill, Aleksandra; Dakheel-Ali, Maha; Heasly, Christopher
2006-01-01
Purpose: Getting dressed is an activity that is of particular difficulty for many persons with dementia, given the need for hand-eye coordination, fine motor skills, and overall planning skills. Despite several studies concerning interventions to improve dressing behavior, very little is known about the dressing process as it is currently…
Women in relationships with cross-dressing men: a descriptive study from a nonclinical setting.
Brown, G R
1994-10-01
Over a 6-year period, 106 women involved with men who cross-dress (mostly heterosexual transvestites) completed a questionnaire regarding themselves, their male partners, and their relationships. Interview data supplemented these questionnaires for 75% of the respondents. All respondents were recruited from nonclinical settings. The "modal" female partner was a 40-year-old Protestant, Caucasian woman, who was a firstborn child, in her first marriage. She was more likely than other women her age to be childless, and to have earned at least a 2-year college degree. She was no more likely to have had lesbian experiences or substance use problems than comparably aged American women. She had been married to her cross-dressing mate for 13 years and had known of his activities for 9 years. A quarter of women reported at least occasional sexual arousal to their mate's cross-dressing. The two variables associated with low acceptance of cross-dressing were discovery of their partner's cross-dressing after marriage and lack of sexual arousal to cross-dressing stimuli. Low acceptance was unrelated to firstborn status, amount of exposure to cross-dressing activities, or having had children. This group may be more representative of women in relationships with cross-dressing men than previous reports limited to cross-dressers and spouses who are in treatment.
Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.
Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G
2016-01-01
Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.
Schramm-Loewner evolution and Liouville quantum gravity.
Duplantier, Bertrand; Sheffield, Scott
2011-09-23
We show that when two boundary arcs of a Liouville quantum gravity random surface are conformally welded to each other (in a boundary length-preserving way) the resulting interface is a random curve called the Schramm-Loewner evolution. We also develop a theory of quantum fractal measures (consistent with the Knizhnik-Polyakov-Zamolochikov relation) and analyze their evolution under conformal welding maps related to Schramm-Loewner evolution. As an application, we construct quantum length and boundary intersection measures on the Schramm-Loewner evolution curve itself.
Human neutrophil elastase and collagenase sequestration with phosphorylated cotton wound dressings.
Edwards, J Vincent; Howley, Phyllis S
2007-11-01
The design and preparation of wound dressings that redress the protease imbalance in chronic wounds is an important goal of wound healing and medical materials science. Chronic wounds contain high levels of tissue and cytokine-destroying proteases including matrix metalloprotease and neutrophil elastase. Thus, the lowering of excessive protease levels in the wound environment by wound dressing sequestration prevents the breakdown of extracellular matrix proteins and growth factors necessary for wound healing. Phosphorylated cotton wound dressings were prepared to target sequestration of proteases from chronic wound exudate through a cationic uptake binding mechanism involving salt bridge formation of the positively charged amino acid side chains of proteases with the phosphate counterions of the wound dressing fiber. Dressings were prepared by applying sodium hexametaphosphate and diammonium phosphate in separate formulations to cotton gauze by pad/dry/cure methods. Phosphorylated cotton dressings were assessed for their ability to lower elastase and collagenase activity. The phosphorylated cotton dressings lowered elastase and collagenase activity 40-80% more effectively than the untreated cotton wound dressings under conditions that mimic chronic wound exudate. Efficacy of the phosphorylated cotton was found to be related to the level of phosphorylation and a lower pH due to protonated phosphate at the surface of the dressing. The capacity of the modified gauze to sequester continued elastase secretions similar to that found in a chronic wound over a 24-h period was retained within a 80% retention of elastase sequestration and was dose-dependent. Copyright (c) 2007 Wiley Periodicals, Inc.
Analysis of the Pressure Distribution Qualities of a Silicone Border Foam Dressing.
Miller, Stephannie K; Sharma, Neal; Aberegg, Lauren C; Blasiole, Kimberly N; Fulton, Judith A
2015-01-01
To determine whether application of a silicone foam dressing is associated with decreased interface pressures when applied to the heel. Prospective, within-subjects design. The study was conducted in a community-based hospital using a convenience sample of 50 healthy volunteers with a mean age of 39.6 years and mean body mass index of 26.6; 70% were female. Application of the silicone border foam dressing was randomized between the left and right heels. Participants were asked to lie down in the supine position on a viscoelastic foam mattress. Interface pressure measurements were captured using a pressure mapping system; measurements were taken once with the dressing applied to the heel (intervention map) and once without (control map). Data were captured after a 4-minute time period allowing stabilization. Analysis was based on mean interface pressure; data points were collected for both heels in each of the 2 frames, yielding 4 observations per subject. Application of the dressing was associated with a significant decrease in average pressure measurements as compared to the heel with no dressing applied (P < .001). Application of the dressing did not impact pressure readings for the heel to which no dressing was applied (P = .53), and application of the dressing to either the left or right heel did not impact pressure readings (ie, the random effect was insignificant; P = .9). Application of a silicone border foam dressing is associated with significant reduction in interface pressure and may be considered as part of a pressure ulcer prevention program.
Enhanced wound contraction in fresh wounds dressed with honey in Wistar rats (Rattus Novergicus).
Osuagwu, F C; Oladejo, O W; Imosemi, I O; Aiku, A; Ekpos, O E; Salami, A A; Oyedele, O O; Akang, E U
2004-01-01
Due to reports that honey accelerates wound healing, an investigation on its role in wound contraction in fresh wounds inflicted on wistar rats was carried out. Twenty adult male wistar rats had 2cm by 2cm square wound inflicted on their right dorsolateral trunk. They were divided into two groups. The experimental group had their wounds dressed with honey while the control group had normal saline dressing. Wound dressing was done every five days and measurements taken at each dressing. Wound morphology was also assessed. Dressing with honey significantly enhanced percentage wound contraction on day 10 with value of 79.20+/-2.94 compared to control value of 53.50+/-4.32. p=0.0. The mean wound measurement on day 10 reduced significantly in honey group, 1.15+/-0.18 compared to control group 2.38+/-0.28. p=0.002. However, there was no significant difference in fibroblast count per high power field in honey group 68.0+/-2.59 compared to control 90.2+/-17.40, p=0.242. Honey dressing increased mean blood vessel count per high power field, 18.8+/-3.77 albeit non significantly when compared to control value of 13.4+/-2.44, p=0.264. Also honey dressing caused increased granulation tissue formation in wounds dressed with honey compared to control group. Our study suggests that honey dressing enhances wound contraction in fresh wounds which is one of the key features of wound healing.
Processing parameter optimization for the laser dressing of bronze-bonded diamond wheels
NASA Astrophysics Data System (ADS)
Deng, H.; Chen, G. Y.; Zhou, C.; Li, S. C.; Zhang, M. J.
2014-01-01
In this paper, a pulsed fiber-laser dressing method for bronze-bonded diamond wheels was studied systematically and comprehensively. The mechanisms for the laser dressing of bronze-bonded diamond wheels were theoretically analyzed, and the key processing parameters that determine the results of laser dressing, including the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles, were proposed for the first time. Further, the effects of these four key parameters on the oxidation-damaged layer of the material surface, the material removal efficiency, the material surface roughness, and the average protrusion height of the diamond grains were explored and summarized through pulsed laser ablation experiments. Under the current experimental conditions, the ideal values of the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles were determined to be 4.2 × 107 W/cm2, 30%, 30%, and 16, respectively. Pulsed laser dressing experiments were conducted on bronze-bonded diamond wheels using the optimized processing parameters; next, both the normal and tangential grinding forces produced by the dressed grinding wheel were measured while grinding alumina ceramic materials. The results revealed that the normal and tangential grinding forces produced by the laser-dressed grinding wheel during grinding were smaller than those of grinding wheels dressed using the conventional mechanical method, indicating that the pulsed laser dressing technology provides irreplaceable advantages relative to the conventional mechanical dressing method.
Siritientong, Tippawan; Angspatt, Apichai; Ratanavaraporn, Juthamas; Aramwit, Pornanong
2014-01-01
An ethyl alcohol-precipitated silk sericin/PVA scaffold that controlled the release of silk sericin was previously developed and applied for the treatment of full-thickness wounds in rats and demonstrated efficient healing. In this study, we aimed to further evaluate the clinical potential of this scaffold, hereafter called "silk sericin-releasing wound dressing", for the treatment of split-thickness skin graft donor sites by comparison with the clinically available wound dressing known as "Bactigras®". In vitro characterization and in vivo evaluation for safety of the wound dressings were performed. A clinical trial of the wound dressings was conducted according to standard protocols. The sericin released from the wound dressing was not toxic to HaCat human keratinocytes. A peel test indicated that the silk sericin-releasing wound dressing was less adhesive than Bactigras®, potentially reducing trauma and the risk of repeated injury upon removal. There was no evidence of skin irritation upon treatment with either wound dressing. When tested in patients with split-thickness skin graft donor sites, the wounds treated with the silk sericin-releasing wound dressing exhibited complete healing at 12 ± 5.0 days, whereas those treated with Bactigras® were completely healed at 14 ± 5.2 days (p = 1.99 × 10(-4)). In addition, treatment with the silk sericin-releasing wound dressing significantly reduced pain compared with Bactigras® particularly during the first 4 postoperative days (p = 2.70 × 10(-5) on day 1). We introduce this novel silk sericin-releasing wound dressing as an alternative treatment for split-thickness skin graft donor sites.
A model for quantitative evaluation of skin damage at adhesive wound dressing removal.
Matsumura, Hajime; Ahmatjan, Niyaz; Ida, Yukiko; Imai, Ryutaro; Wanatabe, Katsueki
2013-06-01
The removal of adhesive wound dressings from the wound surface involves a risk of damaging the intact stratum corneum and regenerating epithelium. Pain associated with the removal of wound dressings is a major issue for patients and medical personnel. Recently, wound dressings coated with a silicone adhesive have been developed to reduce such skin damage and pain on removal and they have received good evaluation in various clinical settings. However, there is neither a standard method to quantify whether or not the integrity of the stratum corneum and regenerating epithelium is retained or if both structures are damaged by the removal of wound dressings, nor are there standardised values with which to assess skin damage. We applied six different types of adhesive wound dressing on plain copy paper printed with black ink by a laser printer, removed the dressings, examined the adhesive-coated surface of the wound dressings using a high-power videoscope, and examined the stripped areas. Wound dressings coated with a silicone adhesive showed significantly less detachment of the stratum corneum and regenerating epithelium, followed by those coated with polyurethane, hydrocolloid, and acrylic adhesives. The assessment method utilised in this study revealed distinct differences between wound dressing types, but less variation in the evaluation outcome of each type. This assessment method may be useful for the evaluation of adhesive wound dressings, particularly during product development. However, further studies will be needed to examine the effectiveness of this assessment method in the clinical setting because the adherent properties of polyurethane and hydrocolloid adhesives may be altered by the absorption of water from the skin. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.
Effect of different wound dressings on cell viability and proliferation.
Paddle-Ledinek, Joanne E; Nasa, Zeyad; Cleland, Heather J
2006-06-01
Many new dressings have been developed since the early 1980s. Wound healing comprises cleansing, granulation/vascularization, and epithelialization phases. An optimum microenvironment and the absence of cytotoxic factors are essential for epithelialization. This study examines the effect of extracts of different wound dressings on keratinocyte survival and proliferation. Keratinocyte cultures were exposed for 40 hours to at least three extracts of each of the following wound dressings, which were tested in octuplicate: Acticoat, Aquacel-Ag, Aquacel, Algisite M, Avance, Comfeel Plus transparent, Contreet-H, Hydrasorb, and SeaSorb. Silicone extract provided the reference material. Controls were included of cells cultured in medium that had been incubated under conditions identical to those used with the extracts. Cell survival (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide reduction) and proliferation (5-bromo-2':-deoxyuridine incorporation) were measured. Extracts of silver-containing dressings (Acticoat, Aquacel-Ag, Contreet-H, and Avance) were most cytotoxic. Extracts of Hydrasorb were less cytotoxic but markedly affected keratinocyte proliferation and morphology. Extracts of alginate-containing dressings (Algisite M, SeaSorb, and Contreet-H) demonstrated high calcium concentrations, markedly reduced keratinocyte proliferation, and affected keratinocyte morphology. Extracts of Aquacel and Comfeel Plus transparent induced small but significant inhibition of keratinocyte proliferation. The principle of minimizing harm should be applied to the choice of wound dressing. Silver-based dressings are cytotoxic and should not be used in the absence of infection. Alginate dressings with high calcium content affect keratinocyte proliferation probably by triggering terminal differentiation of keratinocytes. Such dressings should be used with caution in cases in which keratinocyte proliferation is essential. All dressings should be tested in vitro before clinical application.
Role of natural polysaccharides in radiation formation of PVA hydrogel wound dressing
NASA Astrophysics Data System (ADS)
Varshney, Lalit
2007-02-01
Radiation processed PVA-polysaccharides hydrogels have been observed to be suitable for producing transparent, flexible, mechanically strong, biocompatible, effective and economical hydrogel dressings. The dressings were formed in single stage irradiation process achieving gel formation and sterilization at 25-30 kGy gamma radiation dose. No synthetic plasticizers and additives were used. Different formulations containing poly-vinylalcohol (PVA) and polysaccharides selected from combinations of agar and carrageenan were used to make the dressings. The selected polysaccharides themselves form thermo-reversible gels and degrade on irradiation. Using concentration of polysaccharides as low as 0.5-2% resulted in increase of tensile strength from 45 g/cm 2 to 411 g/cm 2, elongation from 30% to 410% and water uptake from 25% to 157% with respect to PVA gel without polysaccharides. Besides improving mechanical strength, agar contributes more to elongation and carrageenan to mechanical strength of the gel dressing. PVA formulations containing the polysaccharides show significantly different pre-gel viscosities behaviour. Increasing the concentration of agar in the formulation to about 2% converts the sheet gel to paste gel useful for filling wound cavities. The results indicate that pre irradiation network structure of the formulation plays an important role in determining mechanical properties of the irradiated gel dressing. Formulations containing 7-9% PVA, 0.5-1.5% carrageenan and 0.5-1% agar gave highly effective usable hydrogel dressings. Scanning electron micrographs show highly porous structure of the gel. Clinical trials of wound dressing on human patients established safety and efficacy of the dressing. The dressing has been observed to be useful in treating burns, non-healing ulcers of diabetes, leprosy and other external wounds. The dressings are now being marketed in India under different brand names.
Kleidon, Tricia M; Ullman, Amanda J; Gibson, Victoria; Chaseling, Brett; Schoutrop, Jason; Mihala, Gabor; Rickard, Claire M
2017-11-01
To evaluate feasibility of an efficacy trial comparing peripherally inserted central catheter (PICC) dressing and securement techniques to prevent complications and failure. This pilot, 3-armed, randomized controlled trial was undertaken at Royal Children's Hospital and Lady Cilento Children's Hospital, Brisbane, Australia, between April 2014 and September 2015. Pediatric participants (N = 101; age range, 0-18 y) were assigned to standard care (bordered polyurethane [BPU] dressing, sutureless securement device), tissue adhesive (TA) (plus BPU dressing), or integrated securement dressings (ISDs). Average PICC dwell time was 8.1 days (range, 0.2-27.7 d). Primary outcome was trial feasibility including PICC failure. Secondary outcomes were PICC complications, dressing performance, and parent and staff satisfaction. Protocol feasibility was established. PICC failure was 6% (2/32) with standard care, 6% (2/31) with ISD, and 3% (1/32) with TA. PICC complications were 16% across all groups. TA provided immediate postoperative hemostasis, prolonging the first dressing change until 5.5 days compared with 3.5 days and 2.5 days with standard care and ISD respectively. Bleeding was the most common reason for first dressing change: standard care (n = 18; 75%), ISD (n = 11; 69%), TA (n = 4; 27%). Parental satisfaction (median 9.7/10; P = .006) and staff feedback (9.2/10; P = .002) were most positive for ISD. This research suggests safety and acceptability of different securement dressings compared with standard care; securement dressings may also reduce dressing changes after insertion. Further research is required to confirm clinically cost-effective methods to prevent PICC failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Methods/Design Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. Discussion The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613000105741 PMID:24274190
Choi, Young Suk; Gwak, Heui-Chul; Park, Jae Keun; Lim, Ji Yun; Yeo, Eui Dong; Park, Eunseok; Kim, Junyong; Lee, Young Koo
2018-04-13
Silver nanoparticle (AgNP)-containing dressings are used worldwide for the treatment of wounds; however, many studies have indicated that AgNPs are toxic to humans and cause cell death, primarily via apoptosis. In this study, the investigators compare the apoptotic effects of various AgNP dressing materials, with the hypothesis that nanosilver would be less toxic than ionic silver. For the in vivo experiments, Sprague-Dawley (SD) and streptozotocin (STZ)-induced diabetic rats were treated with 5 dressing materials: Aquacel Ag (product A, silver ion; ConvaTec, Berkshire, UK), Acticoat (product B, AgNP; Smith & Nephew, Fort Worth, TX), Medifoam Silver (product C, silver ion; Genewel Science Co Ltd, Seongnam, South Korea), PolyMem Silver (product D, AgNP; Ferris Mfg Corp, Fort Worth, TX), and Vaseline-impregnated dressing gauze (control; Unilever, London, UK). All treatments were applied 3 times per week. After 14 days of treatment, the SD and STZ rats were euthanized, and wound samples were examined for apoptosis. The analysis included immunohistochemistry, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, Western blotting, and reverse transcription polymerase chain reaction for a semiquantitative evaluation of apoptosis. The AgNP-containing dressing materials were more cytotoxic than the silver dressings. Compared with the AgNP dressing materials, no significant levels of apoptotic factors were observed in the silver dressing-treated wounds. The TUNEL staining showed that product C-dressed wounds contained the most apoptotic cells, while some apoptotic cells were observed in product B-dressed wounds. Moreover, apoptotic gene expression was altered, including a decline in B-cell lymphoma-2 and activation of caspase-3. This was most evident in wounds treated with product C. Interestingly, apoptotic gene expression was not induced in product A-treated wounds. Finally, product D had a relatively lower silver concentration and was less toxic than products A-C. Dressing materials containing AgNP have an antimicrobial effect. However, the authors observed that some AgNP dressings induced DNA damage and apoptosis. Although AgNP dressings did not cause significant acute apoptotic effects, they should be examined for cytotoxic effects in chronic wounds and should be used with caution when treating chronic wounds and those with low bacteria counts.
USDA-ARS?s Scientific Manuscript database
Understanding how wound dressings may be designed to address critical unsolved issues in wound repair and treatment influences the development of dressings and new concepts of promoting healing. The vast majority of commercial dressing materials focus on the physical aspects of wounds, e.g., acting ...
School Dress Codes and Uniform Policies.
ERIC Educational Resources Information Center
Anderson, Wendell
2002-01-01
Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Sun, Ming; Li, Kangkang; Wang, Zhiguo; Zhang, Yanpeng
2018-04-01
We study different dressing effects in parametrically amplified four-wave mixing (PA-FWM) processes. By seeding a weak probe laser into the Stokes or anti-Stokes channel of the FWM, the gain process is generated in the so-called bright twin beams which are the probe and conjugate beams. The dressing types dramatically affect the gain factors in both the probe and conjugate channels. The gain factor of the FWM signal decreases under the cascade-type dressing and the signal's shape splits into two dips under this dressing type. However, the intensity of the FWM signal changes from suppression to enhancement under the parallel-type dressing. We will apply this switching process to all-optical switching.
Overview of Silk Fibroin Use in Wound Dressings.
Farokhi, Mehdi; Mottaghitalab, Fatemeh; Fatahi, Yousef; Khademhosseini, Ali; Kaplan, David L
2018-05-12
Recently, biomimetic wound dressings were introduced as potential replacements for treating skin injuries. Although there are some clinically available skin replacements, the range of wound types and locations necessitates a broader range of options for the clinic. Natural polymeric-based dressings are of central interest in this area due to their outstanding biocompatibility, biodegradability, low toxicity, and non-allergenic nature. Among them, silk fibroin (SF) has exceptional characteristics as a wound dressing. SF-based dressings can also be used as carriers for delivering drugs, growth factors, and bioactive agents to the wound area, while providing appropriate support for complete healing. In this review, we describe recent advances in the development of SF-based wound dressings for skin regeneration. Copyright © 2018 Elsevier Ltd. All rights reserved.
A retrospective review of burn dressings on a porcine burn model.
Wang, Xue-Qing; Kravchuk, Olena; Kimble, Roy M
2010-08-01
This is a study to compare wound healing among three types of dressings on a porcine model with deep-dermal-partial-thickness burns. The burns in this study were from eight animal trials conducted in the past for other purposes and only burns with a uniform pale appearance that had served as controls in original experiments were selected. In total, there were 57 burns in 33 pigs, using one of following three dressings: Acticoat (Silver) (3 trials), Jelonet (Gauze) (3 trials), and Solosite Gel/Jelonet (Gel/Gauze) (2 trials). The wound healing assessments included wound re-epithelialisation during a 6-week period, clinical and histological scar assessments at week 6 after burn. Of all wound healing/scar assessments, only re-epithelialisation showed statistical difference between dressings. Earlier re-epithelialisation was observed in Gel/Gauze dressings compared to Silver and/or Gauze dressings. However, this study revealed huge variation in wound healing outcome between 3 trials within both Silver and/or Gauze dressings, supported by significant differences on re-epithelialisation, clinical and histological scar measurements. In addition, it was found that larger animals healed better than smaller ones, based on weights from 21 pigs. Of all dressings, Silver delivers the best protection for wound colonization/infection. Wound colonization/infection was found to confine wound healing and lead to thinner RND in scars. From this study, we cannot find enough evidence to suggest the beneficial effect of one dressing(s) over others on burn wound healing outcome on a porcine model with small deep-dermal-partial-thickness burns with a relative small sample size.
Guo, Chunlan; Deng, Hongyan; Yang, Jian
2015-01-01
To assess the effect of virtual reality distraction on pain among patients with a hand injury undergoing a dressing change. Virtual reality distraction can effectively alleviate pain among patients undergoing a dressing change. Clinical research has not addressed pain control during a dressing change. A randomised controlled trial was performed. In the first dressing change sequence, 98 patients were randomly divided into an experimental group and a control group, with 49 cases in each group. Pain levels were compared between the two groups before and after the dressing change using a visual analog scale. The sense of involvement in virtual environments was measured using the Pearson correlation coefficient analysis, which determined the relationship between the sense of involvement and pain level. The difference in visual analog scale scores between the two groups before the dressing change was not statistically significant (t = 0·196, p > 0·05), but the scores became statistically significant after the dressing change (t = -30·792, p < 0·01). The correlation between the sense of involvement in a virtual environment and pain level during the dressing was statistically significant (R(2) = 0·5538, p < 0·05). Virtual reality distraction can effectively alleviate pain among patients with a hand injury undergoing a dressing change. Better results can be obtained by increasing the sense of involvement in a virtual environment. Virtual reality distraction can effectively relieve pain without side effects and is not reliant on a doctor's prescription. This tool is convenient for nurses to use, especially when analgesics are unavailable. © 2014 John Wiley & Sons Ltd.
Kelleher, Maureen E; Kilcoyne, Isabelle; Dechant, Julie E; Hummer, Emma; Kass, Philip H; Snyder, Jack R
2015-04-01
To determine if application of silver sodium zirconium phosphate polyurethane semi-occlusive foam (SPF) dressing would improve measures of wound healing and decrease bacterial contamination compared with a non-adherent, absorbent dressing applied to wounds created on the distal aspect of the equine limb. Controlled randomized experimental study. Adult Quarter Horse and Thoroughbred horses (n = 5). One 6.25 cm(2) wound was created on the dorsomedial aspect of the proximal metacarpus on each forelimb. A SPF dressing was applied to 1 randomly assigned limb as a treatment and a non-adherent, absorbent dressing was applied to the opposite limb as control. Bandages were changed every 3 days for 60 days. Granulation tissue was scored every 3 days, wound area measured every 6 days, and wound bed was cultured every 12 days. SPF-treatment wounds had significantly decreased wound area and decreased granulation tissue scores when evaluated <30 days and over the 60 day study, although complete wound healing times were not significantly different. Bacteria were cultured from all wounds at varying times throughout the study. The SPF wound dressing improved some measures of wound healing compared with the control dressing, most significantly during the first 30 days. This suggests that the SPF wound dressing may be useful in the early management of wounds on the equine lower limb. Further studies using the SPF dressing are needed to characterize the temporal and cellular effects on wound healing and evaluate this dressing in a clinical environment. © Copyright 2014 by The American College of Veterinary Surgeons.
Elsner, J J; Berdicevsky, I; Zilberman, M
2011-01-01
About 70% of all people with severe burns die from related infections, despite advances in treatment regimens and the best efforts of nurses and doctors. Although silver-eluting wound dressings are available for addressing this problem, there is growing evidence of the deleterious effects of such dressings in delaying the healing process owing to cellular toxicity. A new concept of antibiotic-eluting composite wound dressings is described here. These dressings are based on a polyglyconate mesh coated with a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with antibiotic drugs. The effect of antibiotic release on bacterial inhibition was studied, and cell cytotoxicity was examined. The dressings resulted in a 99.99% decrease in the viable counts of Pseudomonas aeruginosa and Staphylococcus albus at very high initial inoculations of 10⁷-10⁸ CFU ml⁻¹ after only 1 day, while such a decrease in Staphylococcus aureus was obtained within 3 days. Bacterial inhibition zones around the dressing material were found to persist for 2 weeks, indicating a long-lasting antimicrobial effect. Despite severe toxicity to bacteria, the dressing material was found to have no toxic effect on cultured fibroblasts, indicating that the new antibiotic-eluting wound dressings represent an effective option for selective treatment of bacterial infections. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Matsumura, Hajime; Imai, Ryutaro; Ahmatjan, Niyaz; Ida, Yukiko; Gondo, Masahide; Shibata, Dai; Wanatabe, Katsueki
2014-02-01
In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. Various types of adhesives are used on adhesive wound dressings and the extent of skin damage depends on how much an adhesive sticks to the wound or skin surface. We quantitatively determined and compared the amount of stratum corneum removed by eight different wound dressings including polyurethane foam using acrylic adhesive, silicone-based adhesive dressing, composite hydrocolloid and self-adhesive polyurethane foam in healthy volunteers. The results showed that wound dressings with silicone adhesive and self-adhesive polyurethane foam removed less stratum corneum, whereas composite hydrocolloid and polyurethane foam using acrylic adhesive removed more stratum corneum. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
The Effect of Offloading Heels on Sacral Pressure.
Al-Majid, Sadeeka; Vuncanon, Barbara; Carlson, Nika; Rakovski, Cyril
2017-09-01
Offloading a patient's heels during supine surgical procedures is a common practice to prevent heel pressure injuries. This practice may increase sacral pressure and jeopardize sacral skin integrity, but prophylactic dressings may help protect sacral skin. The purpose of this study was to examine the effects of offloading the heels and of multilayered silicone foam dressings on sacral pressure. We measured the sacral pressure of 50 healthy volunteers using a pressure-mapping system under four conditions: heels not offloaded and sacral dressing applied, heels offloaded and dressing applied, heels not offloaded and no dressing, and heels offloaded and no dressing. We used linear mixed-effects modeling to compare the effects of these conditions on sacral pressure. Offloading the heels significantly increased sacral pressure (P < .001), whereas the dressing had no effect on sacral pressure (P = .49). Offloading a patient's heels may increase the risk of sacral pressure injuries. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.
A new postoperative otoplasty dressing technique using cyanoacrylate tissue adhesives.
Vetter, Miriam; Foehn, Matthias; Wedler, Volker
2010-04-01
There are many techniques for cosmetic surgery of the ears and also many different procedures for postoperative treatment. The postoperative dressing is described as important for a successful outcome. We present our method of postoperative dressing in the form of liquid bonding. Cyanoacrylate tissue adhesives as liquid bonding agents are used for fixation of the pinna at the mastoid area. After 10-14 days the bonding can be easily removed. No huge dressings, tapes, or plasters are necessary. The patients are satisfied with the light dressing; they do not feel ashamed to appear in public. We have found this dressing technique to be simple and economical, especially because of the use of the bonding for skin closure before. It can be used after otoplasty with an anterior or a posterior approach.
The role of dressings in the prevention of pressure ulcers.
Brown, Julie
2016-08-11
Pressure ulceration is a significant global healthcare problem and represents a considerable burden on healthcare resources. Within the literature an increasing number of studies have examined the role prophylactic dressings play in redistributing pressure and helping to protect the skin from the effects of friction and shear. The use of dressings to prevent pressure ulcers may be considered a controversial issue, as previous opinion has been that dressings do not reduce the effects of pressure. This article will critically evaluate the literature to examine the role dressings play in the prevention of pressure ulceration.
Foam dressings for treating pressure ulcers.
Walker, Rachel M; Gillespie, Brigid M; Thalib, Lukman; Higgins, Niall S; Whitty, Jennifer A
2017-10-12
Pressure ulcers, also known as pressure injuries and bed sores, are localised areas of injury to the skin or underlying tissues, or both. Dressings made from a variety of materials, including foam, are used to treat pressure ulcers. An evidence-based overview of dressings for pressure ulcers is needed to enable informed decision-making on dressing use. This review is part of a suite of Cochrane Reviews investigating the use of dressings in the treatment of pressure ulcers. Each review will focus on a particular dressing type. To assess the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers in people with an existing pressure ulcer in any care setting. In February 2017 we searched: the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations); Ovid Embase; EBSCO CINAHL Plus and the NHS Economic Evaluation Database (NHS EED). We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. Published or unpublished randomised controlled trials (RCTs) and cluster-RCTs, that compared the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers (Category/Stage II or above). Two review authors independently performed study selection, risk of bias and data extraction. A third reviewer resolved discrepancies between the review authors. We included nine trials with a total of 483 participants, all of whom were adults (59 years or older) with an existing pressure ulcer Category/Stage II or above. All trials had two arms, which compared foam dressings with other dressings for treating pressure ulcers.The certainty of evidence ranged from low to very low due to various combinations of selection, performance, attrition, detection and reporting bias, and imprecision due to small sample sizes and wide confidence intervals. We had very little confidence in the estimate of effect of included studies. Where a foam dressing was compared with another foam dressing, we established that the true effect was likely to be substantially less than the study's estimated effect.We present data for four comparisons.One trial compared a silicone foam dressing with another (hydropolymer) foam dressing (38 participants), with an eight-week (short-term) follow-up. It was uncertain whether alternate types of foam dressing affected the incidence of healed pressure ulcers (RR 0.89, 95% CI 0.45 to 1.75) or adverse events (RR 0.37, 95% CI 0.04 to 3.25), as the certainty of evidence was very low, downgraded for serious limitations in study design and very serious imprecision.Four trials with a median sample size of 20 participants (230 participants), compared foam dressings with hydrocolloid dressings for eight weeks or less (short-term). It was uncertain whether foam dressings affected the probability of healing in comparison to hydrocolloid dressings over a short follow-up period in three trials (RR 0.85, 95% CI 0.54 to 1.34), very low-certainty evidence, downgraded for very serious study limitations and serious imprecision. It was uncertain if there was a difference in risk of adverse events between groups (RR 0.88, 95% CI 0.37 to 2.11), very low-certainty evidence, downgraded for serious study limitations and very serious imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but we assessed the evidence as being of very low certainty.One trial (34 participants), compared foam and hydrogel dressings over an eight-week (short-term) follow-up. It was uncertain if the foam dressing affected the probability of healing (RR 1.00, 95% CI 0.78 to 1.28), time to complete healing (MD 5.67 days 95% CI -4.03 to 15.37), adverse events (RR 0.33, 95% CI 0.01 to 7.65) or reduction in ulcer size (MD 0.30 cm 2 per day, 95% CI -0.15 to 0.75), as the certainty of the evidence was very low, downgraded for serious study limitations and very serious imprecision.The remaining three trials (181 participants) compared foam with basic wound contact dressings. Follow-up times ranged from short-term (8 weeks or less) to medium-term (8 to 24 weeks). It was uncertain whether foam dressings affected the probability of healing compared with basic wound contact dressings, in the short term (RR 1.33, 95% CI 0.62 to 2.88) or medium term (RR 1.17, 95% CI 0.79 to 1.72), or affected time to complete healing in the medium term (MD -35.80 days, 95% CI -56.77 to -14.83), or adverse events in the medium term (RR 0.58, 95% CI 0.33 to 1.05). This was due to the very low-certainty evidence, downgraded for serious to very serious study limitations and imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but again, we assessed the evidence as being of very low certainty.None of the included trials reported quality of life or pressure ulcer recurrence. It is uncertain whether foam dressings are more clinically effective, more acceptable to users, or more cost effective compared to alternative dressings in treating pressure ulcers. It was difficult to make accurate comparisons between foam dressings and other dressings due to the lack of data on reduction of wound size, complete wound healing, treatment costs, or insufficient time-frames. Quality of life and patient (or carer) acceptability/satisfaction associated with foam dressings were not systematically measured in any of the included studies. We assessed the certainty of the evidence in the included trials as low to very low. Clinicians need to carefully consider the lack of robust evidence in relation to the clinical and cost-effectiveness of foam dressings for treating pressure ulcers when making treatment decisions, particularly when considering the wound management properties that may be offered by each dressing type and the care context.
Ullman, Amanda J; Kleidon, Tricia; Gibson, Victoria; McBride, Craig A; Mihala, Gabor; Cooke, Marie; Rickard, Claire M
2017-08-30
Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture-less securement device group. Overall satisfaction was highest in the integrated securement-dressing (mean 8.5/10; standard deviation 1.2). Improved dressing integrity was evident in the intervention arms, with the integrated securement-dressing associated with prolonged time to first dressing change (mean days 3.5). Improving the security and dressing integrity of tunneled CVADs is likely to improve outcomes for pediatric patients. Further research is necessary to identify novel, effective CVAD securement to reduce complications, and provide reliable vascular access for children. ACTRN12614000280606 ; prospectively registered on 17/03/2014.
Percutaneous urinary procedures - discharge
... a shower if you wrap the dressing with plastic wrap and replace the dressing if it gets ... include: Telfa (the dressing material), Tegaderm (the clear plastic tape that holds the plastic ring in place), ...
Fries, C A; Ayalew, Y; Penn-Barwell, J G; Porter, K; Jeffery, S L A; Midwinter, M J
2014-07-01
Recent conflicts have been characterised by the use of improvised explosive devices causing devastating injuries, including heavily contaminated wounds requiring meticulous surgical debridement. After being rendered surgical clean, these wounds are dressed and the patient transferred back to the UK for on-going treatment. A dressing that would prevent wounds from becoming colonised during transit would be desirable. The aim of this study was to establish whether using nanocrystalline silver dressings, as an adjunct to the initial debridement, would positively affect wound microbiology and wound healing compared to standard plain gauze dressings. Patients were prospectively randomised to receive either silver dressings, in a nanocrystalline preparation (Acticoat™), or standard of care dressings (plain gauze) following their initial debridement in the field hospital. On repatriation to the UK microbiological swabs were taken from the dressing and the wound, and an odour score recorded. Wounds were followed prospectively and time to wound healing was recorded. Additionally, patient demographic data were recorded, as well as the mechanism of injury and Injury Severity Score. 76 patients were recruited to the trial between February 2010 and February 2012. 39 received current dressings and 37 received the trial dressings. Eleven patients were not swabbed. There was no difference (p=0.1384, Fishers) in the primary outcome measure of wound colonisation between the treatment arm (14/33) and the control arm (20/32). Similarly time to wound healing was not statistically different (p=0.5009, Mann-Whitney). Wounds in the control group were scored as being significantly more malodorous (p=0.002, Mann-Whitney) than those in the treatment arm. This is the first randomised controlled trial to report results from an active theatre of war. Performing research under these conditions poses additional challenges to military clinicians. Meticulous debridement of wounds remains the critical determinant in wound healing and infection and this study did not demonstrate a benefit of nanocrystaline silver dressing in respect to preventing wound colonisation or promoting healing, these dressings do however seem to significantly reduce the unpleasant odour commonly associated with battlefield wounds. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Bernatchez, Stéphanie F.; Ruckly, Stéphane; Timsit, Jean-François
2015-01-01
Objective To model the cost-effectiveness impact of routine use of an antimicrobial chlorhexidine gluconate-containing securement dressing compared to non-antimicrobial transparent dressings for the protection of central vascular lines in intensive care unit patients. Design This study uses a novel health economic model to estimate the cost-effectiveness of using the chlorhexidine gluconate dressing versus transparent dressings in a French intensive care unit scenario. The 30-day time non-homogeneous markovian model comprises eight health states. The probabilities of events derive from a multicentre (12 French intensive care units) randomized controlled trial. 1,000 Monte Carlo simulations of 1,000 patients per dressing strategy are used for probabilistic sensitivity analysis and 95% confidence intervals calculations. The outcome is the number of catheter-related bloodstream infections avoided. Costs of intensive care unit stay are based on a recent French multicentre study and the cost-effectiveness criterion is the cost per catheter-related bloodstream infections avoided. The incremental net monetary benefit per patient is also estimated. Patients 1000 patients per group simulated based on the source randomized controlled trial involving 1,879 adults expected to require intravascular catheterization for 48 hours. Intervention Chlorhexidine Gluconate-containing securement dressing compared to non-antimicrobial transparent dressings. Results The chlorhexidine gluconate dressing prevents 11.8 infections /1,000 patients (95% confidence interval: [3.85; 19.64]) with a number needed to treat of 85 patients. The mean cost difference per patient of €141 is not statistically significant (95% confidence interval: [€-975; €1,258]). The incremental cost-effectiveness ratio is of €12,046 per catheter-related bloodstream infection prevented, and the incremental net monetary benefit per patient is of €344.88. Conclusions According to the base case scenario, the chlorhexidine gluconate dressing is more cost-effective than the reference dressing. Trial Registration This model is based on the data from the RCT registered with www.clinicaltrials.gov (NCT01189682). PMID:26086783
Desroche, N; Dropet, C; Janod, P; Guzzo, J
2016-10-02
This study was designed to evaluate the antibacterial activity of a wound dressing which combines polyacrylate fibres and a silver lipido-colloid matrix (UrgoClean Ag, silver polyabsorbent dressing), against biofilm of methicillin-resistant Staphylococcus aureus (MRSA). Samples of silver polyabsorbent dressing and the neutral form of this dressing (UrgoClean) were applied to biofilms of MRSA formed on a collagen I-coated surface, cultured for 24 hours. Different exposure times were tested (1, 2, 4 and 7 days) without dressing change. The biofilm reduction was quantified by using culture methods and by confocal laser scanning microscopy experiments. The application of the silver polyabsorbent dressing resulted in a significant decrease of the biofilm population by a log reduction of 4.6, after 24 hours of exposure. Moreover, the antibiofilm activity was maintained for 7 days with reduction values up to 4 log (reduction of biofilm superior to 99.99%). The application of the neutral dressing also induced a significant reduction of the concentration of sessile cells after 1 day (about 0.90 log). The results obtained with this neutral form of the dressing showed that the polyacrylate fibres were able to exert a mechanical disruption of the biofilm architecture. These in vitro experiments demonstrated that silver polyabsorbent dressing was able to strongly reduce the biofilm of MRSA. The antibiofilm mechanism of this dressing can be explained by a dual action of the polyabsorbent fibres (based on ammonium polyacrylate polymer around an acrylic core) which induced a mechanical disruption of the biofilm matrix and/or a sequestration of sessile cells, and the diffusion of silver ions which produced bactericidal activity. This study was supported by Laboratoires Urgo (Dijon). P. Janod is an employee of Laboratoires Urgo. The company had no influence on the experimental design and the interpretation of the results.
2010-01-01
Background The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. Methods In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Results Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Conclusions Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing. PMID:20576085
Nasir, Nur-Azida Mohd; Halim, Ahmad Sukari; Singh, Kirnpal-Kaur Banga; Dorai, Ananda Aravazhi; Haneef, Mehru-Nisha Muhammad
2010-06-24
The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing.
Konstantatos, A H; Angliss, M; Costello, V; Cleland, H; Stafrace, S
2009-06-01
Pain arising in burns sufferers is often severe and protracted. The prospect of a dressing change can heighten existing pain by impacting both physically and psychologically. In this trial we examined whether pre-procedural virtual reality guided relaxation added to patient controlled analgesia with morphine reduced pain severity during awake dressings changes in burns patients. We conducted a prospective randomized clinical trial in all patients with burns necessitating admission to a tertiary burns referral centre. Eligible patients requiring awake dressings changes were randomly allocated to single use virtual reality relaxation plus intravenous morphine patient controlled analgesia (PCA) infusion or to intravenous morphine patient controlled analgesia infusion alone. Patients rated their worst pain intensity during the dressing change using a visual analogue scale. The primary outcome measure was presence of 30% or greater difference in pain intensity ratings between the groups in estimation of worst pain during the dressing change. Of 88 eligible and consenting patients having awake dressings changes, 43 were assigned to virtual reality relaxation plus intravenous morphine PCA infusion and 43 to morphine PCA infusion alone. The group receiving virtual reality relaxation plus morphine PCA infusion reported significantly higher pain intensities during the dressing change (mean=7.3) compared with patients receiving morphine PCA alone (mean=5.3) (p=0.003) (95% CI 0.6-2.8). The addition of virtual reality guided relaxation to morphine PCA infusion in burns patients resulted in a significant increase in pain experienced during awake dressings changes. In the absence of a validated predictor for responsiveness to virtual reality relaxation such a therapy cannot be recommended for general use in burns patients having awake dressings changes.
Dhillon, M; Carter, C P; Morrison, J; Hislop, W S; Currie, W J R
2015-06-01
The success of skin grafting is dependent on the interplay between many factors including nutrient uptake and vascular in-growth. To allow this, it is important that the graft is immobile and traditionally a 'pressure dressing' has been placed over the graft to improve outcome and graft 'take'. We present the findings of our comparative study of full-thickness skin grafts performed in the head, neck and face region over a period of 24 months. We felt that there was an unacceptably high infection rate and graft failure using pressure dressings. Data was collected retrospectively from the case notes on 70 patients who had undergone full-thickness skin grafting to the head, neck and face over a 2 year period. Thirty-five patients underwent grafting with pressure dressing and 35 without. The group with the pressure dressing had the same 'bolster' specification-type dressing and those without had their graft 'quilted' in and chloramphenicol ointment applied topically. Success was determined by the percentage 'take' of the grafts and absence of infection i.e. purulence. Infection in those with a pressure dressing stood at 26 % in contrast to those without, at 9 %. Without a pressure dressing we observed no total graft failures, compared to 6 % in those with a pressure dressing. The results confirmed the perception that there was a higher infection and graft failure rate where a pressure dressing was applied; however, this was not a statistically significant difference and a randomised control trial with a larger sample size would be required to validate the results.
Leaper, David; Nazir, Jameel; Roberts, Chris; Searle, Richard
2010-01-01
In patients at risk of surgical site infection (SSI), there is evidence that an antimicrobial barrier dressing (Acticoat* ) applied immediately post-procedure is effective in reducing the incidence of infection. The objective of this study was to assess when it is appropriate to use an antimicrobial barrier dressing rather than a post-operative film dressing, by evaluating the net cost and budget impact of the two strategies. An economic model was developed, which estimates expected expenditure on dressings and the expected costs of surgical site infection during the initial inpatient episode, based on published literature on the pre-discharge costs of surgical infection and the efficacy of an antimicrobial barrier dressing in preventing SSI. At an SSI risk of 10%, an antimicrobial barrier dressing strategy is cost neutral if the incidence of infection is reduced by at least 9% compared with a post-operative film dressing. At 35% efficacy, expenditure on dressings would be higher by £30,760 per 1000 patients, and the cost of treating infection would be lower by £111,650, resulting in a net cost saving of £80,890. The break-even infection risk for cost neutrality is 2.6%. Although this cost analysis is based on published data, there are limitations in methodology: the model is dependent on and subject to the limitations of the data used to populate it. Further studies would be useful to increase the robustness of the conclusions, particularly in a broader range of surgical specialties. A strategy involving the use of an antimicrobial barrier dressing in patients at moderate (5-10%) or high (>10%) risk of infection appears reasonable and cost saving in light of the available clinical evidence.
Zaller, Johann G; König, Nina; Tiefenbacher, Alexandra; Muraoka, Yoko; Querner, Pascal; Ratzenböck, Andreas; Bonkowski, Michael; Koller, Robert
2016-08-17
Seed dressing with pesticides is widely used to protect crop seeds from pest insects and fungal diseases. While there is mounting evidence that especially neonicotinoid seed dressings detrimentally affect insect pollinators, surprisingly little is known on potential side effects on soil biota. We hypothesized that soil organisms would be particularly susceptible to pesticide seed dressings as they get in direct contact with these chemicals. Using microcosms with field soil we investigated, whether seeds treated either with neonicotinoid insecticides or fungicides influence the activity and interaction of earthworms, collembola, protozoa and microorganisms. The full-factorial design consisted of the factor Seed dressing (control vs. insecticide vs. fungicide), Earthworm (no earthworms vs. addition Lumbricus terrestris L.) and collembola (no collembola vs. addition Sinella curviseta Brook). We used commercially available wheat seed material (Triticum aesticum L. cf. Lukullus) at a recommended seeding density of 367 m(-2). Seed dressings (particularly fungicides) increased collembola surface activity, increased the number of protozoa and reduced plant decomposition rate but did not affect earthworm activity. Seed dressings had no influence on wheat growth. Earthworms interactively affected the influence of seed dressings on collembola activity, whereas collembola increased earthworm surface activity but reduced soil basal respiration. Earthworms also decreased wheat growth, reduced soil basal respiration and microbial biomass but increased soil water content and electrical conductivity. The reported non-target effects of seed dressings and their interactions with soil organisms are remarkable because they were observed after a one-time application of only 18 pesticide treated seeds per experimental pot. Because of the increasing use of seed dressing in agriculture and the fundamental role of soil organisms in agroecosystems these ecological interactions should receive more attention.
Toon, Clare D; Lusuku, Charnelle; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2015-09-03
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In March 2015 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Toon, Clare D; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2013-09-05
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In July 2013 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.
Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N
2018-04-01
Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.
Enhancing pressure ulcer prevention using wound dressings: what are the modes of action?
Call, Evan; Pedersen, Justin; Bill, Brian; Black, Joyce; Alves, Paulo; Brindle, C Tod; Dealey, Carol; Santamaria, Nick; Clark, Michael
2015-08-01
Recent clinical research has generated interest in the use of sacral wound dressings as preventive devices for patients at risk of ulceration. This study was conducted to identify the modes of action through which dressings can add to pressure ulcer prevention, for example, shear and friction force redistribution and pressure distribution. Bench testing was performed using nine commercially available dressings. The use of dressings can reduce the amplitude of shear stress and friction reaching the skin of patients at risk. They can also effectively redirect these forces to wider areas which minimises the mechanical loads upon skeletal prominences. Dressings can redistribute pressure based upon their effective Poisson ratio and larger deflection areas, providing greater load redistribution. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Heffernan, A; Martin, A J
1994-01-01
A clinical study of 96 patients compared a new hydrocolloid dressing (Granuflex Extra Thin) with a non-adherent dressing (perforated film absorbent dressing) in the management of lacerations, abrasions and minor operation incisions at the Accident and Emergency (A&E) Department of the University College Hospital, Galway. While time to heal was similar for both groups, the patients using Granuflex Extra Thin experienced less pain (P < 0.001), required less analgesia (P = 0.0154) and were able to carry out their normal daily activities including bathing or showering without affecting the dressing or the wound. Patient satisfaction with the new dressing appeared to be very high especially in those patients who pursued an active lifestyle. PMID:7894807
Elsner, Jonathan J; Egozi, Dana; Ullmann, Yehuda; Berdicevsky, Israela; Shefy-Peleg, Adaya; Zilberman, Meital
2011-08-01
Approximately 70% of all people with severe burns die from related infections despite advances in treatment regimens and the best efforts of nurses and doctors. Silver ion-eluting wound dressings are available for overcoming this problem. However, there are reports of deleterious effects of such dressings due to cellular toxicity that delays the healing process, and the dressing changes needed 1-2 times a day are uncomfortable for the patient and time consuming for the stuff. An alternative concept in wound dressing design that combines the advantages of occlusive dressings with biodegradability and intrinsic topical antibiotic treatment is described herewith. The new composite structure presented in this article is based on a polyglyconate mesh and a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with gentamicin developed to provide controlled release of antibiotics for three weeks. In vivo evaluation of the dressing material in contaminated deep second degree burn wounds in guinea pigs (n=20) demonstrated its ability to accelerate epithelialization by 40% compared to an unloaded format of the material and a conventional dressing material. Wound contraction was reduced significantly, and a better quality scar tissue was formed. The current dressing material exhibits promising results, does not require frequent bandage changes, and offers a potentially valuable and economic approach to treating the life-threatening complication of burn-related infections. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Release of antibiotics from collagen dressing.
Grzybowski, J; Antos-Bielska, M; Ołdak, E; Trafny, E A
1997-01-01
Our new collagen dressing has been developed recently. Three types (A, B, and C) of the dressing were prepared in this study. Each type contained bacitracin, neomycin or colistin. The antibiotic was input into: i. collagen sponge (CS)--type A, ii. layer of limited hydrophobicity (LLH)--type B, and iii. into both CS and LLH layers--type C. The final concentration of the antibiotic that resulted from the loading level was 2 mg/cm2 for the dressings of type A and B and 4 mg/cm2 for the dressing of type C. The antibiotics were then extracted from the pieces of dressings for two days through dialysis membrane. Susceptibility of 54 bacterial strains (S. aureus, P. aeruginosa, and Acinetobacter) isolated from burn wounds were tested to the three antibiotics used for preparation of the dressings. The results of the study evidenced that efficiency of released of antibiotics into the extracts depended on the kind of antibiotic and on the type of dressing. The concentration of the antibiotics proved to be much higher than MIC90 values of the bacterial isolates tested in respect to their susceptibility. The dressing containing mixture of the three antibiotics in two layers--CS and LLH is now considered as potentially effective for care of infected wounds. It may be useful for the treatment of infected wounds or for profilaxis of contaminated wounds, ensuring: i. sufficient antimicrobial activity in wound, and ii. optimal wound environment for the presence of collagenic biomaterial on the damaged tissue.
Bi-Layer Wound Dressing System for Combat Casualty Care
2004-09-01
C. Bonacorsi, M.S.G. Raddi, and I.Z. Carlos. 2004. Cytotoxicity of chlorhexidine digluconate to murine macrophages and its effect on hydrogen...chlorexhidine digluconate or 1 % chloramphenicol, as described previously. Each experimental dressing was then covered with a piece of sterile parafilm...chloramphenicol-loaded dressings were 2-log lower for the first 24 h than when applying the chlorhexidine -loaded dressings (Figure 2). However, there was no
Mendes, D A; Veiga, D F; Veiga-Filho, J; Loyola, A B A T; Paiva, L F; Novo, N F; Sabino-Neto, M; Ferreira, L M
2018-06-01
Concepts regarding the best way to treat a surgical wound vary, in literature, ranging from no dressing use to dressing maintenance for 24 to 48 hours or until suture removal. This study aimed to evaluate the influence of the length of dressing maintenance after breast augmentation with implants on cutaneous colonization and surgical site infection. This is a two-arm, parallel group, randomized clinical trial. Eighty patients who were candidates for augmentation mammoplasty with silicone implants were randomly allocated to two groups, in which the dressing was removed on postoperative day 1 (group A, n = 40) or postoperative day 6 (group B, n = 40). Cutaneous colonization was examined by culturing samples collected before and after dressing removal. The criteria defined by the Centers for Disease Control and Prevention were used to assess surgical site infection. No significant difference regarding cutaneous colonization was observed between groups before dressing application. On postoperative day 6, significantly more bacterial growth was observed in group A (p = 0.01). No surgical site infection occurred. We concluded that maintaining the dressing for 6 days led to a lower cutaneous colonization but did not influence surgical site infection rates. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The clinical and cost effectiveness of bee honey dressing in the treatment of diabetic foot ulcers.
Moghazy, A M; Shams, M E; Adly, O A; Abbas, A H; El-Badawy, M A; Elsakka, D M; Hassan, S A; Abdelmohsen, W S; Ali, O S; Mohamed, B A
2010-09-01
Honey is known, since antiquity, as an effective wound dressing. Emergence of resistant strains and the financial burden of modern dressings, have revived honey as cost-effective dressing particularly in developing countries. Its suitability for all stages of wound healing suggests its clinical effectiveness in diabetic foot wound infections. Thirty infected diabetic foot wounds were randomly selected from patients presenting to Surgery Department, Suez Canal University Hospital, Ismailia, Egypt. Honey dressing was applied to wounds for 3 months till healing, grafting or failure of treatment. Changes in grade and stage of wounds, using University of Texas Diabetic Wound Classification, as well as surface area were recorded weekly. Bacterial load was determined before and after honey dressing. Complete healing was significantly achieved in 43.3% of ulcers. Decrease in size and healthy granulation was significantly observed in another 43.3% of patients. Bacterial load of all ulcers was significantly reduced after the first week of honey dressing. Failure of treatment was observed in 6.7% of ulcers. This study proves that commercial clover honey is a clinical and cost-effective dressing for diabetic wound in developing countries. It is omnipresence and concordance with cultural beliefs makes it a typical environmentally based method for treating these conditions. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Milne, Stephen D; Seoudi, Ihab; Al Hamad, Hanadi; Talal, Talal K; Anoop, Anzila A; Allahverdi, Niloofar; Zakaria, Zain; Menzies, Robert; Connolly, Patricia
2016-12-01
Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large-scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed. © 2015 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.
Chetverikov, Andrey; Ivanchei, Ivan
2016-08-01
In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.
Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel
NASA Astrophysics Data System (ADS)
Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie
2011-05-01
Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.
Tiny patients, tiny dressings: a guide to the neonatal PICC dressing change.
Sharpe, Elizabeth L
2008-06-01
Advances in neonatology now support the survival of the tiniest of infants. The peripherally inserted central catheter (PICC) has now become an integral part of routine practice in neonatal intensive care units around the world. Keen attention to safe maintenance of these devices is essential. A properly applied and maintained PICC dressing is the first line of defense to minimize the risk of complications such as dislodgement, migration, and infection. This article describes a neonatal PICC dressing change and discusses the frequently encountered quandaries surrounding this important procedure, including dressing materials, frequency, site preparation, barrier precautions, and other relevant concerns.
Constructing medical social authority on dress in Victorian Canada.
O'Connor, Eileen
2008-01-01
During the late-Victorian period, campaigns to "reform" middle-class women's dress were grounded in discourses on health, eugenics, declining birth rates, comfort, and aesthetics. In Britain, the United States and Germany, organized "dress reform" movements emerged in the latter half of the 19th century, while in Canada the campaign was led primarily by physicians through public health education. This article explores the discussion on women's dress in public health literature in Canadian circulation between 1860-1900 and interprets findings within a feminist poststructuralist framework that posits the understanding of women's bodies and gender regulation to be central to knowledge construction on women's dress.
Bonferoni, Maria Cristina; Sandri, Giuseppina; Rossi, Silvia; Dellera, Eleonora; Invernizzi, Alessandro; Boselli, Cinzia; Cornaglia, Antonia Icaro; Del Fante, Claudia; Perotti, Cesare; Vigani, Barbara; Riva, Federica; Caramella, Carla; Ferrari, Franca
2018-02-09
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds.
Bonferoni, Maria Cristina; Dellera, Eleonora; Invernizzi, Alessandro; Cornaglia, Antonia Icaro; Perotti, Cesare; Vigani, Barbara; Caramella, Carla; Ferrari, Franca
2018-01-01
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds. PMID:29425164
Boonbaichaiyapruck, S; Hutayanon, P; Chanthanamatta, P; Dumrongwatana, T; Intarayotha, N; Krisdee, V; Yamvong, S
2001-12-01
Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.
Effects of honey and sugar dressings on wound healing.
Mphande, A N G; Killowe, C; Phalira, S; Jones, H Wynn; Harrison, W J
2007-07-01
To investigate whether there is a difference between the efficacy of honey and sugar as wound dressings. Patients with open or infected wounds were randomised to receive either honey or sugar dressings. Bacterial colonisation, wound size, wound ASEPSIS score and pain were assessed at the start of treatment and at weekly intervals until full healing occurred. Forty patients were enrolled; 18 received sugar dressings and 22 honey dressings. In the honey group, 55% of patients had positive wound cultures at the start of treatment and 23% at one week, compared with 52% and 39% respectively in the sugar group.The median rate of healing in the first two weeks of treatment was 3.8cm2/week for the honey group and 2.2cm2/week for the sugar group. After three weeks of treatment 86% of patients treated with honey had no pain during dressing changes, compared with 72% treated with sugar. Honey appears to be more effective than sugar in reducing bacterial contamination and promoting wound healing, and slightly less painful than sugar during dressing changes and motion.
The brain's dress code: How The Dress allows to decode the neuronal pathway of an optical illusion.
Schlaffke, Lara; Golisch, Anne; Haag, Lauren M; Lenz, Melanie; Heba, Stefanie; Lissek, Silke; Schmidt-Wilcke, Tobias; Eysel, Ulf T; Tegenthoff, Martin
2015-12-01
Optical illusions have broadened our understanding of the brain's role in visual perception. A modern day optical illusion emerged from a posted photo of a striped dress, which some perceived as white and gold and others as blue and black. Here we show, using functional magnetic resonance imaging (fMRI), that those who perceive The Dress as white/gold have higher activation in response to the image of The Dress in brain regions critically involved in higher cognition (frontal and parietal brain areas). These results are consistent with theories of top-down modulation and present a neural signature associated with the differences in perceiving The Dress as white/gold or blue/black. Furthermore the results support recent psychophysiological data on this phenomenon and provide a fundamental building block to study interindividual differences in visual processing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Felgueiras, H. P.; Amorim, M. T. P.
2017-10-01
Modern wound dressings combine medical textiles with active compounds that stimulate wound healing while protecting against infection. Electrospun wound dressings have been extensively studied and the electrospinning technique recognized as an efficient approach for the production of nanoscale fibrous mats. The unique diverse function and architecture of antimicrobial peptides (AMPs) has attracted considerable attention as a tool for the design of new anti-infective drugs. Functionalizing electrospun wound dressings with these AMPs is nowadays being researched. In the present work, we explore these new systems by highlighting the most important characteristics of electropsun wound dressings, revealing the importance of AMPs to wound healing, and the methods available to functionalize the electrospun mats with these molecules. The combined therapeutic potential of collagen type I and these AMP functionalized dressings will be highlighted as well; the significance of these new strategies for the future of wound healing will be clarified.
NASA Astrophysics Data System (ADS)
Nita, Gelu M.; Viall, Nicholeen M.; Klimchuk, James A.; Loukitcheva, Maria A.; Gary, Dale E.; Kuznetsov, Alexey A.; Fleishman, Gregory D.
2018-01-01
The study of time-dependent solar active region (AR) morphology and its relation to eruptive events requires analysis of imaging data obtained in multiple wavelength domains with differing spatial and time resolution, ideally in combination with 3D physical models. To facilitate this goal, we have undertaken a major enhancement of our IDL-based simulation tool, GX_Simulator, previously developed for modeling microwave and X-ray emission from flaring loops, to allow it to simulate quiescent emission from solar ARs. The framework includes new tools for building the atmospheric model and enhanced routines for calculating emission that include new wavelengths. In this paper, we use our upgraded tool to model and analyze an AR and compare the synthetic emission maps with observations. We conclude that the modeled magneto-thermal structure is a reasonably good approximation of the real one.
Mancano, Michael A
2017-04-01
The purpose of this feature is to heighten awareness of specific adverse drug reactions (ADRs), discuss methods of prevention, and promote reporting of ADRs to the US Food and Drug Administration's (FDA's) MedWatch program (800-FDA-1088). If you have reported an interesting, preventable ADR to MedWatch, please consider sharing the account with our readers. Write to Dr. Mancano at ISMP, 200 Lakeside Drive, Suite 200, Horsham, PA 19044 (phone: 215-707-4936; e-mail: mmancano@temple.edu). Your report will be published anonymously unless otherwise requested. This feature is provided by the Institute for Safe Medication Practices (ISMP) in cooperation with the FDA's MedWatch program and Temple University School of Pharmacy. ISMP is an FDA MedWatch partner.
[Split-thickness skin graft donor site: which dressing use?].
Caliot, J; Bodin, F; Chiriac, S; Correia, N; Poli-Mérol, M-L; François-Fiquet, C
2015-04-01
The management of split-thickness skin graft donor sites is targeted towards promoting the healing process, reducing pain. This has been an inconclusive topic. The aim of this study was to list and to discuss the French practices in term of split-thickness skin graft (STSG) donor site dressing. Multicentric national study by questionnaire (Google Drive(®)) for the attention of the plastic and/or pediatric surgeons. The type of dressing used on skin and sclap and the rhythm of dressing changes were analyzed. The study included 26 surgical centers on 40 contacted. The alginate is mainly used (Algostéril(®)) (17/26). It is left in position until healing (13/17). Five other types of dressings have been reported: paraffin gauze (3/26), lipidocolloides (1/26), Mepitel(®) (1/26), Mepilex(®) (1/26), indifferent use of gauze or alginate dressings (4/26). Twenty-two out of 26 centers make no difference in dressing choice between skin and scalp. Medical practices did not differ between adult or pediatric departments. Cost-effectiveness has become an important issue in wound management, requiring judicious use. The lack of consensus regarding split-thickness skin graft donor site dressing and our clinical practices force us to reconsider the best therapeutic option. This study coupled with the analysis of the literature highlights the difficulties of the practitioner in choosing the best dressing. The alginate seems to get the preference of our practices by its ease of use, its absence of change (reduces pain by limiting manipulations) and its moderate cost. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
A comparison of an antibacterial sandwich dressing vs dressing containing silver.
Krasowski, Grzegorz; Jawień, Arkadiusz; Tukiendorf, Andrzej; Rybak, Zbigniew; Junka, Adam; Olejniczak-Nowakowska, Małgorzata; Bartoszewicz, Marzenna; Smutnicka, Danuta
2015-01-01
The purpose of this study was to compare the efficacy of dressings containing octenidine vs. dressings containing silver in the wound healing in the course of a chronic venous disease. There were two groups of 40 patients who met the inclusion criteria and who did not meet the exclusion criteria. The patients were randomly assigned into the groups (envelope method). The first, "O group" was treated with octenidine-based dressings. The second, "S group" was treated with silver dressings. The study lasted for 56 days. All patients in the research were treated with medical compression stockings with cotton understockings. Microbiological eradication was observed on the 28th day of the study among 33% of patients in the treatment group vs. 6% in control group. On the 56th day of the treatment, these percentages equalled 72% and 35%. The rate of healing was faster in the 0 group than in the S group. In the wounds <10 cm(2) it was faster by 1.35 cm(2)/week and in wounds >10 cm(2) it equalled 3.44 cm(2). The reduction of pain level was 37.5% higher in the O group, in contrast with the S group. One change of a dressing in the O group led to a 0.06 cm(2) greater wound size reduction and in the case of wounds >10 cm(2) to 0.29 cm(2) reduction compared with the S group. The presented results indicate that the efficacy of dressings containing octenidine is higher compared to silver dressings. © 2015 by the Wound Healing Society.
Jung, Jae-A; Yoo, Ki-Hyun; Han, Seung-Kyu; Dhong, Eun-Sang; Kim, Woo-Kyung
2016-12-01
To demonstrate the efficacy of a highly hydrophilic polyurethane foam dressing in the treatment of diabetic ulcers. Diabetic foot ulcers often pose a difficult treatment problem. Polyurethane foam dressings have been used worldwide to accelerate wound healing, but only a few clinical studies demonstrate the effect of foam dressing on the healing of diabetic ulcers. Medical records of 1342 patients with diabetic ulcers who were admitted and treated at the authors' institution were reviewed. A total of 208 patients met the study's inclusion criteria. Of these 208 patients, 137 were treated with a highly hydrophilic polyurethane foam dressing, and 71 were treated with saline gauze (control group). Except for the application of polyurethane foam dressing, the treatment method was identical for patients in both groups. The wound healing outcomes of the 2 groups were compared. Complete wound healing occurred in 87 patients (63.5%) in the polyurethane foam dressing group and in 28 patients (39.4%) in the control group within 12 weeks (P < .05, X test). The mean percentage of wound area reduction in both groups was statistically significant (P < .05, Mann-Whitney U test). The mean time required for complete closure in patients who achieved complete healing within 12 weeks was 6.2 (SD, 3.4) weeks and 7.3 (SD, 2.6) weeks in the polyurethane foam dressing and control groups, respectively (P < .05, Mann-Whitney U test). These results indicate that the highly hydrophilic polyurethane foam dressing may provide an effective treatment strategy for diabetic foot ulcers.
NASA Astrophysics Data System (ADS)
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Lazǎr, Veronica; Chifiriuc, Mariana Carmen
2012-12-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
2012-01-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues. PMID:23272823
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Laz R, Veronica; Chifiriuc, Mariana Carmen
2012-12-31
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
Exploratory Development of an Ultrafast-Curing Wound Dressing
1991-05-31
mils thick: Formulation 2 and 5 .. 36 17. Elution Rates for the 30% Chlorhexidine Gluconate ADD’s at t=0 and Stored at the Temperature Extremes (400C...determined from the in vivo trials conducted earlier (9). The 6 mil thick dressing (Formulation 2) demonstrated effectiveness when tested on guinea pigs...This dressing released approximately 3000 micrograms/sq. cm. in 72 hours or about 64% of the 12 mil dressing tested for shelf stability (Figure 16
Woo, Kevin Y
2015-07-01
The purpose of this study was to examine the mediating effect of anxiety in the relationship between anticipation and pain in people with chronic wounds. Pain is common in people with chronic wounds. Anticipation or negative expectation of discomfort has been shown to have an augmenting effect on pain; also known as nocebo hyperalgesia. This was a cross-sectional study with repeated measures. Prior to dressing change, anticipatory pain level was evaluated by a 11-point numerical rating scale and anxiety by the Six-items State-Trait Anxiety Inventory (STAI-6). During wound dressing changes, pain was measured before dressing removal, at dressing removal, at cleansing and dressing application using the numerical scale. Analysis was completed based on the data from a convenience sample of 96 patients. Participants reported more pain at cleansing and dressing removal than baseline. High levels of anticipation, anxiety and pain at dressing change for wounds were related to heavy exudate and wound that were covered with necrotic tissue. Finally, the relationship between anticipation and pain perception was mediated by anxiety. Anticipation of pain triggers anxiety that can lead to increased pain. There is a need to incorporate evaluation of anxiety and personal expectations as part of comprehensive pain assessment. Clinicians should be aware of the impact of emotions and anticipation on overall pain experience. © 2015 John Wiley & Sons Ltd.
Ng, Shiow-Fern; Lew, Pit-Chin; Sin, Yong-Boey
2014-11-01
Topical emollients are known to provide symptomatic relief for atopic dermatitis. In hospitals, wet-wrap therapy has been shown to benefit children with moderate-to-severe atopic dermatitis (AD), but the application of wet-wraps is tedious and time-consuming. Topical emollients have low residence time and often dry out easily. The aim of this work was to develop a hydrogel-gauze dressing that is not only easy to apply but also rehydrates and traps moisture to provide longer relief for AD patients. In this study, a prototype hydrogel-gauze dressing was developed with varying ratios of sodium carboxymethylcellulose (NaCMC) and propylene glycol. The hydrogel-gauze dressings were assessed based on the moisture vapor transmission rate, moisture absorption, mechanical properties and storage stability over three months. Then, the efficacy of the hydrogel-gauze dressing was compared to topical emollients using transgenic NC/Nga mice with AD-like lesions. The NaCMC hydrogel-gauze dressings significantly lowered transepidermal water loss, and the animals displayed a faster recovery, which indicates that hydrogel-gauze dressings can trap moisture more effectively and accelerate AD healing. Hence, we propose that hydrogel-gauze dressings can potentially become an alternative to wet-wrap therapy due to the ease of application and the higher efficacy compared to topical products.
Van Hoesel, Willem; Tiefenbacher, Alexandra; König, Nina; Dorn, Verena M; Hagenguth, Julia F; Prah, Urša; Widhalm, Theresia; Wiklicky, Viktoria; Koller, Robert; Bonkowski, Michael; Lagerlöf, Jan; Ratzenböck, Andreas; Zaller, Johann G
2017-01-01
Seed dressing, i.e., the treatment of crop seeds with insecticides and/or fungicides, aiming to protect seeds from pests and diseases, is widely used in conventional agriculture. During the growing season, those crop fields often receive additional broadband herbicide applications. However, despite this broad utilization, very little is known on potential side effects or interactions between these different pesticide classes on soil organisms. In a greenhouse pot experiment, we studied single and interactive effects of seed dressing of winter wheat ( Triticum aestivum L. var. Capo ) with neonicotinoid insecticides and/or strobilurin and triazolinthione fungicides and an additional one-time application of a glyphosate-based herbicide on the activity of earthworms, soil microorganisms, litter decomposition, and crop growth. To further address food-web interactions, earthworms were introduced to half of the experimental units as an additional experimental factor. Seed dressings significantly reduced the surface activity of earthworms with no difference whether insecticides or fungicides were used. Moreover, seed dressing effects on earthworm activity were intensified by herbicides (significant herbicide × seed dressing interaction). Neither seed dressings nor herbicide application affected litter decomposition, soil basal respiration, microbial biomass, or specific respiration. Seed dressing did also not affect wheat growth. We conclude that interactive effects on soil biota and processes of different pesticide classes should receive more attention in ecotoxicological research.
Gerçeker, Gülçin Özalp; Yardımcı, Figen; Aydınok, Yeşim
2017-06-01
To compare the effects of the care bundles including chlorhexidine dressing and advanced dressings on the catheter-related bloodstream infection (CRBSI) rates in pediatric hematology-oncology patients with central venous catheters (CVCs). Twenty-seven PHO patients were recruited to participate in a prospective, randomized study in Turkey. The researcher used care bundles with chlorhexidine dressing in the experimental group (n = 14), and care bundles with advanced dressings in the control group (n = 13). According to the study results, 28.6% of the patients in the experimental group had CRBSI, while this rate was 38.5% in the control group patients. The CRBSI rate in the experimental group was 3.9, and the control group had 4.4 per 1000 inpatient catheter days. There was no exit-site infection in the experimental group. However, the control group had 1.7 per 1000 inpatient catheter days. Even though there was no difference between the two groups in which the researcher implemented care bundles with chlorhexidine dressing and advanced dressings in terms of CRBSI development, there was reduction in the CRBSI rates thanks to the care bundle approach. It is possible to control the CRBSI rates using care bundles in pediatric hematology-oncology patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-08-12
The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-01-01
Background The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Material/Methods Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. Results All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Conclusions Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used. PMID:26264209
Suzuki, Makoto; Yamada, Sumio; Omori, Mikayo; Hatakeyama, Mayumi; Sugimura, Yuko; Matsushita, Kazuhiko; Tagawa, Yoshikatsu
2008-09-01
A patient with poststroke hemiparesis learns to use the nonparetic arm to compensate for the weakness of the paretic arm to achieve independence in dressing. This is the learning process of new component actions on dressing. The purpose of this study was to develop the Upper-Body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the component actions of upper-body dressing, and to provide preliminary data on internal consistency of the UBDS, as well as its reproducibility, validity, and sensitivity to clinical change. Correlational study of concurrent validity and reliability in which 63 consecutive stroke patients were enrolled in the study and were assessed repeatedly by the UBDS and the dressing item of Functional Independent Measure (FIM). Fifty-one patients completed the 3-wk study. The Cronbach's coefficient alpha of UBDS was 0.88. The principal component analysis extracted two components, which explained 62.3% of total variance. All items of the scale had high loading on the first component (0.65-0.83). Actions on the paralytic side were the positive loadings and actions on the healthy side were the negative loadings on the second component. Intraclass correlation coefficient was 0.87. The level of correlation between UBDS score and FIM dressing item scores was -0.72. Logistic regression analysis showed that only the score of UBDS on the first day of evaluation was a significant independent predictor of dressing ability (odds ratio, 0.82; 95% confidence interval, 0.71-0.95). The UBDS scores for paralytic hand passed into the sleeve, sleeve pulled up beyond the elbow joint, and sleeve pulled up beyond the shoulder joint were worse than the score for the other components of the task. These component actions had positive loading on the second component, which was identified by the principal component analysis. The UBDS has good internal consistency, reproducibility, validity, and sensitivity to clinical changes of patients with poststroke hemiparesis. This detailed UBDS assessment enables us to document the most difficult stages in dressing and to assess motor and process skills for independence of dressing.
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (LEFT) AND DRESSED, DRY-LAID RETAINING WALL (RIGHT). FACING WEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (RIGHT) AND DRESSED, DRY-LAID RETAINING WALL (LEFT). FACING NORTHWEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
Junka, Adam F; Żywicka, Anna; Szymczyk, Patrycja; Dziadas, Mariusz; Bartoszewicz, Marzena; Fijałkowski, Karol
2017-12-01
In the present article, we propose a simple Antibiofilm Dressing's Activity Measurement (A.D.A.M.) test that allows to check in vitro a dressing's suitability against biofilm-related wound infections. To perform the test, three agar discs are covered with biofilm formed by the tested pathogen after which they are assembled one over another in the form of an agar plug and placed in the well of a 24-well plate. The top disc is covered with the analyzed dressing and the entire set is incubated for 24h. During this time, the investigated antimicrobial substance is released from the dressing and penetrates to subsequent biofilm-covered agar discs. Biofilm reduction is measured using 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) spectrometric assay and the results are compared to untreated control samples (agar plug covered with biofilm and without the dressing/or with a passive dressing placed on the top disc). Furthermore, in order to standardize the differences in penetrability of the drugs released from active dressings the results can be expressed as a dimensionless value referred to as the Penetrability Index. In summary, A.D.A.M. test is simple, cheap, can be performed practically in every clinical laboratory and takes no more time than routine microbiological diagnostics. Apart from measuring the released drug's activity, the A.D.A.M. test allows to assess drug penetrability (across three agar discs), reflecting real wound conditions, where microbes are frequently hidden under the necrotic tissue or cloth. In conclusion, the A.D.A.M. test produces a high volume of data that, when analyzed, can provide a researcher with a valuable hint concerning the applicability of active dressings against specific biofilm pathogens in a particular setting. Copyright © 2017 Elsevier B.V. All rights reserved.
Lo, Shu-Fen; Chang, Chee-Jen; Hu, Wen-Yu; Hayter, Mark; Chang, Yu-Ting
2009-03-01
The purpose of this study was to examine the efficacy of silver-releasing dressings in the management of non-healing chronic wounds. Non-healing chronic wounds often have a negative physical impact on patients and place a financial burden on healthcare systems. Silver dressings are wound products designed to control infection and provide a wound environment conducive to healing. However, validation of the clinical efficacy of these dressings is lacking. Systematic review and meta-analysis. A systematic search of the major electronic databases PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO, OCLC and Proquest between 1950-June 2007 was conducted. Hand searches of selected periodicals, textbooks and checking reference lists and contacting experts was also performed. Eight studies were selected from a potentially relevant 1957 references screened. Analysis incorporated data from 1399 participants in the eight randomised control trials. We found that silver dressings significantly improved wound healing (CI(95): 0.16-0.39, p < 0.001), reduced odour (CI(95): 0.24-0.52, p < 0.001) and pain-related symptoms (CI(95): 0.18-0.47, p < 0.001), decreased wound exudates (CI(95): 0.17-0.44, p < 0.001) and had a prolonged dressing wear time (CI(95): 0.19-0.48, p = 0.028) when compared with alternative wound management approaches. An analysis of sensitivity in these studies by subgroup analysis generally supported these associations. Furthermore, studies indicated an improvement in quality of life (CI(95): 0.04-0.33, p = 0.013) using silver dressings in wound management with no associated severe adverse events. This meta-analysis confirms the effectiveness of silver dressings in wound healing and improving patients' quality of life. However, it also highlights the need for additional well-designed randomised controlled trials to evaluate the effectiveness of silver-related dressings further. The results of this study provide objective data on the effectiveness of silver-related dressing when applied to non-healing chronic wounds.
NASA Astrophysics Data System (ADS)
Chen, Mingjun; Li, Ziang; Yu, Bo; Peng, Hui; Fang, Zhen
2013-09-01
In the grinding of high quality fused silica parts with complex surface or structure using ball-headed metal bonded diamond wheel with small diameter, the existing dressing methods are not suitable to dress the ball-headed diamond wheel precisely due to that they are either on-line in process dressing which may causes collision problem or without consideration for the effects of the tool setting error and electrode wear. An on-machine precision preparation and dressing method is proposed for ball-headed diamond wheel based on electrical discharge machining. By using this method the cylindrical diamond wheel with small diameter is manufactured to hemispherical-headed form. The obtained ball-headed diamond wheel is dressed after several grinding passes to recover geometrical accuracy and sharpness which is lost due to the wheel wear. A tool setting method based on high precision optical system is presented to reduce the wheel center setting error and dimension error. The effect of electrode tool wear is investigated by electrical dressing experiments, and the electrode tool wear compensation model is established based on the experimental results which show that the value of wear ratio coefficient K' tends to be constant with the increasing of the feed length of electrode and the mean value of K' is 0.156. Grinding experiments of fused silica are carried out on a test bench to evaluate the performance of the preparation and dressing method. The experimental results show that the surface roughness of the finished workpiece is 0.03 μm. The effect of the grinding parameter and dressing frequency on the surface roughness is investigated based on the measurement results of the surface roughness. This research provides an on-machine preparation and dressing method for ball-headed metal bonded diamond wheel used in the grinding of fused silica, which provides a solution to the tool setting method and the effect of electrode tool wear.
Zhou, Xin; Wang, He; Zhang, Jimin; Li, Xuemei; Wu, Yifan; Wei, Yongzhen; Ji, Shenglu; Kong, Deling; Zhao, Qiang
2017-05-01
Wound healing dressings are increasingly needed clinically due to the large number of skin damage annually. Nitric oxide (NO) plays a key role in promoting wound healing, thus biomaterials with NO-releasing property receive increasing attention as ideal wound dressing. In present study, we prepared a novel functional wound dressing by combining electrospun poly(ε-caprolactone) (PCL) nonwoven mat with chitosan-based NO-releasing biomaterials (CS-NO). As-prepared PCL/CS-NO dressing released NO sustainably under the physiological conditions, which was controlled by the catalysis of β-galactosidase. In vivo wound healing characteristics were further evaluated on full-thickness cutaneous wounds in mice. Results showed that PCL/CS-NO wound dressings remarkably accelerated wound healing process through enhancing re-epithelialization and granulation formation and effectively improved the organization of regenerated tissues including epidermal-dermal junction, which could be ascribed to the pro-angiogenesis, immunomodulation, and enhanced collagen synthesis provided by the sustained release of NO. Therefore, PCL/CS-NO may be a promising candidate for wound dressings, especially for the chronic wound caused by the ischemia. Serious skin damage caused by trauma, surgery, burn or chronic disease has become one of the most serious clinical problems. Therefore, there is an increasing demand for ideal wound dressing that can improve wound healing. Due to the vital role of nitric oxide (NO), we developed a novel functional wound dressing by combining electrospun polycaprolactone (PCL) mat with NO-releasing biomaterial (CS-NO). The sustained release of NO from PCL/CS-NO demonstrated positive effects on wound healing, including pro-angiogenesis, immunomodulation, and enhanced collagen synthesis. Hence, wound healing process was remarkably accelerated and the organization of regenerated tissues was effectively improved as well. Taken together, PCL/CS-NO dressing may be a promising candidate for wound treatment, especially for the chronic wound caused by the ischemia. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin.
Zillmer, R; Agren, M S; Gottrup, F; Karlsmark, T
2006-05-01
To study the effect of repeated removal of four different adhesive dressings on peri-ulcer skin using quantitative non-invasive techniques. Forty-five patients with open (n = 29) or healed (n = 16) venous leg ulcers were included. Peri-ulcer skin was treated for 14 days with patches of two different hydrocolloid-based adhesive dressings, one polyurethane adhesive and one soft silicone adhesive dressing. Normal skin of the patients' ventral forearm was also treated identically. Adhesive patches of the dressings were replaced every second day. The skin barrier function was assessed by measuring transepidermal water loss and stratum corneum hydration by measuring electrical conductance. Thirty-nine patients completed the study. The hydrocolloid adhesives increased transepidermal water loss and conductance while the polyurethane and soft silicone adhesives did not influence these parameters significantly compared with adjacent non-treated peri-ulcer skin. For normal forearm skin, similar relative effects among the four adhesives were found. Repetitive treatment with hydrocolloid-based adhesive dressings induced major functional alterations of the stratum corneum. In contrast, a polyurethane adhesive and a soft silicone adhesive dressing did not alter transepidermal water loss or conductance of peri-ulcer skin.
Peroxide-based oxygen generating topical wound dressing for enhancing healing of dermal wounds.
Chandra, Prafulla K; Ross, Christina L; Smith, Leona C; Jeong, Seon S; Kim, Jaehyun; Yoo, James J; Harrison, Benjamin S
2015-01-01
Oxygen generating biomaterials represent a new trend in regenerative medicine that aims to generate and supply oxygen at the site of requirement, to support tissue healing and regeneration. To enhance the healing of dermal wounds, we have developed a highly portable, in situ oxygen generating wound dressings that uses sodium percarbonate (SPO) and calcium peroxide (CPO) as chemical oxygen sources. The dressing continuously generated oxygen for more than 3 days, after which it was replaced. In the in vivo testing on porcine full-thickness porcine wound model, the SPO/CPO dressing showed enhanced wound healing during the 8 week study period. Quantitative measurements of wound healing related parameters, such as wound closure, reepithelialization, epidermal thickness and collagen content of dermis showed that supplying oxygen topically using the SPO/CPO dressing significantly accelerated the wound healing. An increase in neovascularization, as determined using Von Willebrand factor (vWF) and CD31 staining, was also observed in the presence of SPO/CPO dressing. This novel design for a wound dressing that contains oxygen generating biomaterials (SPO/CPO) for supplying topical oxygen, may find utility in treating various types of acute to chronic wounds. © 2015 by the Wound Healing Society.
Misgav, Mudi; Kenet, Gili; Martinowitz, Uriel
2014-03-01
Bleeding episodes in patients with congenital or acquired bleeding disorders are usually managed with factor concentrates or blood products. However, external and accessible bleeds may effectively be managed with topical hemostasis. After the application of the Hemcon, a Food and Drug Administration-approved chitosan-based hemostatic dressing was used as the "last resort" to successfully control external bleeds in 2 patients with severe bleeding disorders. We describe a single-center experience with this dressing, including its use in pediatric patients as the first mode of therapy. A total of 5 patients (median age 2 y) with severe bleeding disorders were treated with topical chitosan-based dressing for a total of 6 bleeding episodes. The dressing was used either after the failure of extensive systemic therapy or as the first choice of treatment. In 4 of the 6 episodes, bleeding ceased immediately alleviating the need for systemic therapy. There was no rebleeding after the removal of the dressing and no adverse events or local skin reactions were recorded. Hemostatic dressings, such as the chitosan, should be encouraged for the treatment of external/accessible bleeds, especially among the pediatric patients with bleeding tendency.
Plasma treatments of dressings for wound healing: a review.
Eswaramoorthy, Nithya; McKenzie, David R
2017-12-01
This review covers the use of plasma technology relevant to the preparation of dressings for wound healing. The current state of knowledge of plasma treatments that have potential to provide enhanced functional surfaces for rapid and effective healing is summarized. Dressings that are specialized to the needs of individual cases of chronic wounds such as diabetic ulcers are a special focus. A summary of the biology of wound healing and a discussion of the various types of plasmas that are suitable for the customizing of wound dressings are given. Plasma treatment allows the surface energy and air permeability of the dressing to be controlled, to ensure optimum interaction with the wound. Plasmas also provide control over the surface chemistry and in cases where the plasma creates energetic ion bombardment, activation with long-lived radicals that can bind therapeutic molecules covalently to the surface of the dressing. Therapeutic innovations enabled by plasma treatment include the attachment of microRNA or antimicrobial peptides. Bioactive molecules that promote subsequent cell adhesion and proliferation can also be bound, leading to the recruitment of cells to the dressing that may be stem cells or patient-derived cells. The presence of a communicating cell population expressing factors promotes healing.
Topical Application of Honey on Surgical Wounds: A Randomized Clinical Trial.
Goharshenasan, Peiman; Amini, Shahideh; Atria, Ali; Abtahi, Hamidreza; Khorasani, Ghasemali
2016-01-01
The antimicrobial and anti-inflammatory activity of honey and its ability to accelerate wound healing make it an attractive option in surgical wound care. We performed a randomized clinical trial to compare the efficacy of honey dressing with conventional dressing regarding the aesthetic outcome. Bilateral symmetric incisions in randomly selected plastic surgical patients were randomly covered postoperatively with conventional dressing and honey dressing for five days. The aesthetic outcome of the two sides was rated on a Visual Analog Scale by the surgeon and the patient and compared at month three and six after surgery. Seventy two symmetrical incisions in 52 patients were evaluated during the study. The mean width of the scar after the third and the sixth month was 3.64 +/- 0.83 mm and 3.49 +/- 0.87 mm on the side that received honey dressing and 5.43 +/- 0.05 mm and 5.30+/- 1.35 mm in the control group. Wilcoxon signed-rank test showed significant difference between honey and conventional dressing outcomes at third and sixth month (p < 0.001). The healing process of the surgical wound and its final aesthetic result could be improved by using honey dressing. © 2016 S. Karger GmbH, Freiburg.
Aduba, Donald C.; Yang, Hu
2017-01-01
Wound dressings are critical for wound care because they provide a physical barrier between the injury site and outside environment, preventing further damage or infection. Wound dressings also manage and even encourage the wound healing process for proper recovery. Polysaccharide biopolymers are slowly becoming popular as modern wound dressings materials because they are naturally derived, highly abundant, inexpensive, absorbent, non-toxic and non-immunogenic. Polysaccharide biopolymers have also been processed into biomimetic platforms that offer a bioactive component in wound dressings that aid the healing process. This review primarily focuses on the fabrication and biocompatibility assessment of polysaccharide materials. Specifically, fabrication platforms such as electrospun fibers and hydrogels, their fabrication considerations and popular polysaccharides such as chitosan, alginate, and hyaluronic acid among emerging options such as arabinoxylan are discussed. A survey of biocompatibility and bioactive molecule release studies, leveraging polysaccharide’s naturally derived properties, is highlighted in the text, while challenges and future directions for wound dressing development using emerging fabrication techniques such as 3D bioprinting are outlined in the conclusion. This paper aims to encourage further investigation and open up new, disruptive avenues for polysaccharides in wound dressing material development. PMID:28952482
Aramwit, Pornanong; Yamdech, Rungnapha; Ampawong, Sumate
2016-05-01
One approach in wound dressing development is to incorporate active molecules or drugs in the dressing. In order to reduce the frequency of dressing changes as well as to prolong wound healing efficacy, wound dressings that can sustain the release of the active molecules should be developed. In our previous work, we developed chitosan/sericin (CH/SS) microspheres that released sericin in a controlled rate. However, the difficulty of applying the microspheres that easily diffuse and quickly degrade onto the wound was its limitations. In this study, we aimed to develop wound dressing materials which are easier to apply and to provide extended release of sericin. Different amounts of CH/SS microspheres were embedded into various compositions of polyvinyl alcohol/gelatin (PVA/G) scaffolds and fabricated using freeze-drying and glutaraldehyde crosslinking techniques. The obtained CH/SS microspheres-embedded scaffolds with appropriate design and formulation were introduced as a wound dressing material. Sericin was released from the microspheres and the scaffolds in a sustained manner. Furthermore, an optimized formation of the microspheres-embedded scaffolds (2PVA2G+2CHSS) was shown to possess an effective antimicrobial activity against both gram-positive and gram-negative bacteria. These microspheres-embedded scaffolds were not toxic to L929 mouse fibroblast cells, and they did not irritate the tissue when applied to the wound. Finally, probably by the sustained release of sericin, these microspheres-embedded scaffolds could promote wound healing as well as or slightly better than a clinically used wound dressing (Allevyn®) in a mouse model. The antimicrobial CH/SS microspheres-embedded PVA/G scaffolds with sustained release of sericin would appear to be a promising candidate for wound dressing application.
Assadian, Ojan; Arnoldo, Brett; Purdue, Gary; Burris, Agnes; Skrinjar, Edda; Duschek, Nikolaus; Leaper, David J
2015-06-01
This prospective, randomised study compares a new transforming methacrylate dressing (TMD) with a silver-containing carboxymethylcellulose dressing (CMC-Ag) after application to split-thickness skin graft (STSG) donor sites. This was an unblinded, non-inferiority, between-patient, comparison study that involved patients admitted to a single-centre burn unit who required two skin graft donor sites. Each patient's donor sites were covered immediately after surgery: one donor site with TMD and the other with CMC-Ag. The donor sites were evaluated until healing or until 24 days post-application, whichever came first. Study endpoints were time to healing, daily pain scores, number of dressing changes, patient comfort and physicians' and patients' willingness to use the dressings in the future. Nineteen patients had both the dressings applied. No statistically significant difference was noted in time to healing between the two dressings (14·2 days using TMD compared with 13·2 days using CMC-Ag). When pain scores were compared, TMD resulted in statistically significantly less pain at three different time periods (2-5 days, 6-10 days and 11-15 days; P < 0·001 at all time periods). Patients also reported greater comfort with TMD (P < 0·001). Users rated TMD as being less easy to use because of the time and technique required for application. Reductions in pain and increased patient comfort with the use of the TMD dressing, compared with CMC-Ag, were seen as clinical benefits as these are the major issues in donor site management. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wang, Li; Li, Lin-Feng
2017-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a severe drug-induced hypersensitivity reaction characterized by skin rash, fever, blood abnormalities, and multiple organ involvement. The diagnosis of DRESS syndrome is often delayed because of its variable presentation. Prompt withdrawal of the culprit drug is the definitive treatment. DRESS syndrome induced by antituberculosis drugs has rarely been reported. A 50-year-old man admitted to our hospital with recurrent episodes of progressive rash, fever, eosinophilia, lymphadenopathy, hepatic, and pulmonary involvement were experienced after repeat trials of the same antituberculosis drugs. We diagnosed it as DRESS caused by antituberculosis drugs. The case responded well to treatment with systemic corticosteroids and intravenous immunoglobulins. However, repeated bouts of infection with methicillin-resistant Staphylococcus aureus occurred during treatment (clavicular osteomyelitis and knee septic arthritis). He was cured after treatment with linezolid. The patient was discharged on day 112. At 8-month follow-up, there was no relapse of drug eruption and joint swelling. Early diagnosis and prompt withdrawal of all suspected drugs is a key tenet of the treatment of DRESS. Our case report highlights the risks inherent in delayed diagnosis of DRESS and the challenges in the clinical management of this condition. Pulmonary manifestations with radiological changes on chest X-ray and CT can be seen in DRESS. These changes need to be differentiated from those caused by pulmonary infections. Clavicular osteomyelitis infected with MRSA may be caused by iatrogenic injury during subclavian vein catheterization. This type of MRSA infections should be treated for 4 to 6 weeks. Blood eosinophilia could be a useful marker of disease progression and treatment response in patients with DRESS. However, more experience and clinical evidence is needed to confirm this.
Nakagami, Gojiro; Sanada, Hiromi; Konya, Chizuko; Kitagawa, Atsuko; Tadaka, Etsuko; Matsuyama, Yutaka
2007-09-01
This paper is a report of an evaluation of the effectiveness of a newly developed dressing for preventing persistent erythema and pressure ulcer development and improving the water-holding capacity without increasing the skin pH in bedridden older patients. Shear forces and skin dryness play important roles in persistent erythema and pressure ulcer development. To eliminate these risks, we developed a dressing to reduce shear forces and improve the water-holding capacity. However, the effects of this dressing in clinical settings remain unknown. An experimental bilateral comparison study was conducted at a hospital in Japan in 2004 with 37 bedridden older patients at risk of pressure ulcer development. The dressing was randomly applied to the right or left greater trochanter for 3 weeks. No dressing was applied to the opposite side as a control. The skin was monitored weekly during the 3-week application for persistent erythema and pressure ulcer development. Skin hydration and pH were also assessed during the intervention and for 1 week after dressing removal. The incidence of persistent erythema was significantly lower in the intervention area than the control area [P = 0.007, RR 0.18 (95% CI: 0.05-0.73) and NNT 4.11 (2.50-11.63) ]. No pressure ulcers occurred in either the intervention or control area. Skin hydration increased significantly during dressing application and remained high after removal (P < 0.001) relative to the control area. Skin pH decreased significantly during the application (P < 0.001) but returned to control levels after removal (P = 0.38). This safe and effective dressing can be used for patients with highly prominent bones and dry skin to prevent pressure ulcers.
Patients' attitudes toward the attire of male physicians: a single-center study in Saudi Arabia.
Batais, Mohammad Ali
2014-01-01
The doctor-patient relationship has been influenced by the appearance of physicians, and there is an association between a physician's physical appearance and the patients' initial perceptions of physician competence. This study aims to explore patients' preferences toward the attire of a male physician, and to examine if a physician's choice of uniform influences the degree of trust, confidence, and follow-up care among respondents. A cross-sectional survey conducted among patients of the Alwazarat family medicine center in Riyadh, Saudi Arabia. A self-administered questionnaire was completed by 300 patients (50% were male and 83.6% had received a secondary education; the mean age was 33.4 [10.1] years) in the Alwazarat family medicine center in Riyadh. The questionnaire was also customized for the local setting with the inclusion of photos of a male doctor in Saudi Arabian national costume, and 3 other dress styles (Western dress with white coat, scrubs with white coat, and scrubs only). Overall, across all questions regarding physician dress style preferences, participants significantly preferred Western dress (39.9%, P < .001), followed by Saudi national dress (26.3%), a scrub suit with a white coat (22.3%), and scrubs only (11.5%). Respondents reported that they were more likely to follow medical advice and would return for follow-up care if a physician wore Western dress. They were significantly more willing to share their social, sexual, and psychological problems with a physician wearing Saudi national dress (P < .001). The importance of a physician's appearance was ranked significantly higher by older patients (P=.002). Respondents were more likely to favor a physician wearing Western attire with a white coat. However, Saudi national dress, followed by Western dress, is the preferred attire when physicians are dealing with social, sexual, and psychological problems.
Chin, Chai-Yee; Jalil, Juriyati; Ng, Pei Yuen; Ng, Shiow-Fern
2018-02-15
M.oleifera is a medicinal plant traditionally used for skin sores, sore throat and eye infections. Recently, the wound healing property of the leaves of M. oleifera was has been well demonstrated experimentally in both in vivo and in vitro models. However, there is a lack of research which focuses on formulating M.oleifera into a functional wound dressing. In this study, the M.oleifera leaf standardized aqueous extract with highest potency in vitro migration was formulated into a film for wound healing application. Firstly, M. oleifera leaf were extracted in various solvents (aqueous, 50%, 70% and 100% ethanolic extracts) and standardized by reference standards using UHPLC technique. The extracts were then tested for cell migration and proliferation using HDF and HEK cell lines. M. oleifera leaf aqueous extract was then incorporated into alginate-pectin (SA-PC) based film dressing. The film dressings were characterized for the physicochemical properties and the bioactives release from the M. oleifera leaf extract loaded film dressing was also investigated using Franz diffusion cells. All extracts were found to contain vicenin-2, chlorogenic acid, gallic acid, quercetin, kaempferol, rosmarinic acid and rutin. Among all M. oleifera extracts, aqueous standardized leaf extracts showed the highest human dermal fibroblast and human keratinocytes cells proliferation and migration properties. Among the film formulations, SA-PC (3% w/v) composite film dressing containing M. oleifera aqueous leaf extract was found to possess optimal physicochemical properties as wound dressing. A potentially applicable wound dressing formulated as an alginate-pectin film containing aqueous extracts of M. oleifera has been developed. The dressing would be suitable for wounds with moderate exudates. Copyright © 2017 Elsevier B.V. All rights reserved.
Biffi, Roberto; Fattori, Luca; Bertani, Emilio; Radice, Davide; Rotmensz, Nicole; Misitano, Pasquale; Cenciarelli, Sabine; Chiappa, Antonio; Tadini, Liliana; Mancini, Marina; Pesenti, Giovanni; Andreoni, Bruno; Nespoli, Angelo
2012-05-23
An antimicrobial dressing containing ionic silver was found effective in reducing surgical-site infection in a preliminary study of colorectal cancer elective surgery. We decided to test this finding in a randomized, double-blind trial. Adults undergoing elective colorectal cancer surgery at two university-affiliated hospitals were randomly assigned to have the surgical incision dressed with Aquacel Ag Hydrofiber dressing or a common dressing. To blind the patient and the nursing and medical staff to the nature of the dressing used, scrub nurses covered Aquacel Ag Hydrofiber with a common wound dressing in the experimental arm, whereas a double common dressing was applied to patients of control group. The primary end-point of the study was the occurrence of any surgical-site infection within 30 days of surgery. A total of 112 patients (58 in the experimental arm and 54 in the control group) qualified for primary end-point analysis. The characteristics of the patient population and their surgical procedures were similar. The overall rate of surgical-site infection was lower in the experimental group (11.1% center 1, 17.5% center 2; overall 15.5%) than in controls (14.3% center 1, 24.2% center 2, overall 20.4%), but the observed difference was not statistically significant (P = 0.451), even with respect to surgical-site infection grade 1 (superficial) versus grades 2 and 3, or grade 1 and 2 versus grade 3. This randomized trial did not confirm a statistically significant superiority of Aquacel Ag Hydrofiber dressing in reducing surgical-site infection after elective colorectal cancer surgery. Clinicaltrials.gov: NCT00981110.
Payne, Caroline; Edwards, Daren
2014-01-01
Objectives: Traumatic wounds and surgery inherently have their complications. Localized infections, wound dehiscence, and excessive wound leakage can be devastating to the patient with a prolonged recovery, but it is also costly to the hospital with an increased length of stay, extra workload, and dressing changes. The single use PICO (Smith and Nephew Healthcare, Hull, United Kingdom) negative pressure wound therapy (NPWT) dressing has revolutionized our management of various acute, chronic, and high output wounds. It requires fewer dressing changes than conventional practice, is used in the outpatient setting, and is a necessary adjuvant therapy to hasten wound healing. Aims: To observe the efficacy of the PICO vacuum-assisted healing within a cost improvement programme. Settings: Plastic surgery department, Royal London Hospital. Materials and Methods: Twenty-one patients with a diversity of postoperative or posttraumatic wounds were considered suitable for PICO application and treated totally on an outpatient basis once the PICO dressing was applied. All wounds were then subjected to continued PICO dressings until healed. Results: All patients tolerated the PICO well with no dressing failure or failure to comply. The number of dressings per patient ranged from 1 to 7. The cost per patient of treatment ranged from £120 to £1578. Estimated cost of all PICO dressing for 21 patients including plastic surgery dressing clinic appointments = £13,345. Median length of treatment to healing (days) = 16; standard deviation = 9.5. Eight patients would have had an inpatient bed stay with conventional therapy, total 24 bed days saved at Bartshealth @£325 per day. Conclusions: The outpatient application of a disposable NPWT can benefit a wide range of clinical wounds that optimizes patient care, promotes rapid wound healing, and importantly helps manage costs. PMID:24917894
Devices and dressings to secure peripheral venous catheters to prevent complications.
Marsh, Nicole; Webster, Joan; Mihala, Gabor; Rickard, Claire M
2015-06-12
A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically. To assess the effects of PVC dressings and securement devices on the incidence of PVC failure. We searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard methodological procedures expected by Cochrane. We included six RCTs (1539 participants) in this review. Trial sizes ranged from 50 to 703 participants. These six trials made four comparisons, namely: transparent dressings versus gauze; bordered transparent dressings versus a securement device; bordered transparent dressings versus tape; and transparent dressing versus sticking plaster. There is very low quality evidence of fewer catheter dislodgements or accidental removals with transparent dressings compared with gauze (two studies, 278 participants, RR 0.40; 95% CI 0.17 to 0.92, P = 0.03%). The relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47 to 1.68) and infiltration (RR 0.80; 95% CI 0.48 to 1.33) are unclear. The relative effects on PVC failure of a bordered transparent dressing and a securement device have been assessed in only one small study and these were unclear. There was very low quality evidence from the same single study of less frequent dislodgement or accidental catheter removal with bordered transparent dressings than securement devices (RR 0.14, 95% CI 0.03 to 0.63) but more phlebitis with bordered dressings (RR 8.11, 95% CI 1.03 to 64.02) (very low quality evidence). A small single study compared bordered transparent dressings with tape and found very low quality evidence of more PVC failure with the bordered dressing (RR 1.84, 95% CI 1.08 to 3.11) but the relative effects on dislodgement were not clear (very low quality evidence). The relative effects of transparent dressings and a sticking plaster have only been compared in one small study and are unclear. More high quality RCTs are required to determine the relative effects of alternative PVC dressings and securement devices. It is not clear if any one dressing or securement device is better than any other in securing peripheral venous catheters. There is a need for further, independent high quality trials to evaluate the many traditional as well as the newer, high use products. Given the large cost differences between some different dressings and securement devices, future trials should include a robust cost-effectiveness analysis.
González, Arturo
2016-01-01
This case study describes treatment for a 52-year-old man with a recurrent venous leg ulcer using a collagen dressing with extracellular matrix. The patient was admitted to the wound care service for a 3-week-old recurrent venous ulcer. Treatment included application of a collagen dressing with extracellular matrix twice weekly or as needed by the patient; application of a secondary dressing (4 × 4 gauze); and coverage with an expandable netting or gauze using a conforming stretch gauze bandage and latex-free dressing retention tape. The initial venous leg ulcer in this patient required 10 weeks to achieve closure. Ninety-eight percent resolution of the recurrent ulcer had occurred within 4 weeks of treatment, with complete closure at 7 weeks. The average healing time for recurrent venous ulcers is reported in the literature to be longer than initial venous ulcers. In the case provided, collagen ECM dressings promoted complete wound healing in 49 days.
Application of VitaVallis dressing for infected wounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirilova, N. V., E-mail: n.kirilova@vitavallis.com; Fomenko, A. N., E-mail: alserova@ispms.tsc.ru; Korovin, M. S., E-mail: msk@ispms.tsc.ru
Today there is a growing demand for safe and efficient antimicrobial dressings for infected wound treatment. The antimicrobial sorption material for VitaVallis dressings was produced by one-stage oxidation of aluminum nanopowder in water in the presence of fibrous acetylcellulose matrix. Scanning electron microscopy revealed that the material is made up of fibers of diameter 1.5–3.0 µm with adhered agglomerated alumina nanosheets. An antimicrobial study revealed a high inhibitory effect of VitaVallis against the growth of gram-negative (E.coli, P. aeruginosa) and gram-positive (S. aureus) strains. The antimicrobial activity of the dressing against microbial pathogens on the wound surface was demonstrated in inmore » vivo experiments on male rats. The dressing was also tested on volunteer patients. The testing showed reduction of the wound healing period, accelerated cleaning of the infected wound and enhanced tissue regeneration in the wound. The results demonstrate that the VitaVallis dressing can be used for the treatment of deep infected wounds.« less
Waring, Mike; Bielfeldt, Stephan; Mätzold, Katja; Wilhelm, Klaus-Peter
2013-02-01
Chronic wounds require frequent dressing changes. Adhesive dressings used for this indication can be damaging to the stratum corneum, particularly in the elderly where the skin tends to be thinner. Understanding the level of damage caused by dressing removal can aid dressing selection. This study used a novel methodology that applied a stain to the skin and measured the intensity of that stain after repeated application and removal of a series of different adhesive types. Additionally, a traditional method of measuring skin barrier damage (transepidermal water loss) was also undertaken and compared with the staining methodology. The staining methodology and measurement of transepidermal water loss differentiated the adhesive dressings, showing that silicone adhesives caused least trauma to the skin. The staining methodology was shown to be as effective as transepidermal water loss in detecting damage to the stratum corneum and was shown to detect disruption of the barrier earlier than the traditional technique. © 2012 John Wiley & Sons A/S.
Controlled trial of Iodosorb in chronic venous ulcers.
Ormiston, M C; Seymour, M T; Venn, G E; Cohen, R I; Fox, J A
1985-01-01
Cadexomer iodine (Iodosorb) is a hydrophilic starch powder containing iodine, which is a suitable dressing for granulating wounds such as venous ulcers. A total of 61 outpatients with chronic venous ulcers participated in a randomised optional crossover trial using cadexomer iodine or a standard dressing for their ulcers. The trial lasted for 24 weeks or until the ulcer had healed. Two patients withdrew during the course of the trial. Both treatments were highly effective, but the epithelium of ulcers dressed with cadexomer iodine grew again significantly faster (p less than 0.001). At the midpoint of the trial (12th week) 13 of 30 patients receiving standard treatment were changed to cadexomer iodine, while only three of 29 receiving cadexomer iodine changed to the standard dressing (p less than 0.02). In most cases ulcers were dressed and rebandaged daily by the patients themselves after instruction and supervision. This may be better than having dressings and bandages applied by professionals less regularly. PMID:3926169
Gelam (Melaleuca spp.) Honey-Based Hydrogel as Burn Wound Dressing
Mohd Zohdi, Rozaini; Abu Bakar Zakaria, Zuki; Yusof, Norimah; Mohamed Mustapha, Noordin; Abdullah, Muhammad Nazrul Hakim
2012-01-01
A novel cross-linked honey hydrogel dressing was developed by incorporating Malaysian honey into hydrogel dressing formulation, cross-linked and sterilized using electron beam irradiation (25 kGy). In this study, the physical properties of the prepared honey hydrogel and its wound healing efficacy on deep partial thickness burn wounds in rats were assessed. Skin samples were taken at 7, 14, 21, and 28 days after burn for histopathological and molecular evaluations. Application of honey hydrogel dressings significantly enhanced (P < 0.05) wound closure and accelerated the rate of re-epithelialization as compared to control hydrogel and OpSite film dressing. A significant decrease in inflammatory response was observed in honey hydrogel treated wounds as early as 7 days after burn (P < 0.05). Semiquantitative analysis using RT-PCR revealed that treatment with honey hydrogel significantly (P < 0.05) suppressed the expression of proinflammatory cytokines (IL-1α, IL-1β, and IL-6). The present study substantiates the potential efficacy of honey hydrogel dressings in accelerating burn wound healing. PMID:21941590
EL Omairi, Nissrine; Abourazzak, Sanae; Chaouki, Sanae; Atmani, Samir; Hida, Moustapha
2014-01-01
Drug-induced hypersensitivity or Drug Reaction with Eosinophilia and Systemic Symptom (DRESS) is a severe adverse drug-induced reaction. Diagnosing DRESS is challenging due to the diversity of cutaneous eruption and organs involved. Most of the aromatic anticonvulsants, such as phenytoin, phenobarbital, and carbamazepine, can induce DRESS. Culprit drug withdrawal and corticosteroids constituted the mainstay of DRESS treatment. We describe a 6 year-old boy who presented fever and rash 4 weeks after starting carbamazepine. Investigation revealed leukocytosis, atypical lymphocytosis, and elevated serum transaminases. The diagnosis of DREES syndrome was made, Carbamazepine was stopped and replaced initially by Clobazam and by Valproic acid after discharge, no systemic corticotherapy was prescribed. Symptoms began to resolve within two weeks, and by one month later her laboratory values had returned to normal. The aim of this work is to raise awareness general practitioner and pediatricians to suspect Dress syndrome in patients who present with unusual complaints and skin findings after starting any antiepileptic drug. PMID:25360193
Evaluation of a honey-impregnated tulle dressing in primary care.
Stephen-Haynes, Jackie
2004-06-01
Honey has been used for its healing properties for centuries and has been used to dress wounds with favourable results. The emergence of antibiotic resistance and growing interest in "natural" or "complementary" therapies has led to an interest in honey dressings. Much of the research to date has been related to honey's antibacterial properties. However, the healing properties claimed for honey also include stimulating new tissue growth, moist wound healing, fluid handling and promoting epithelialization. Until recently, honey had not been developed as a wound management product and was not a certified pharmaceutical device. Activon Tulle is a sterile, non-adherent dressing impregnated with Leptospermum scoparium hone. The claimed properties of honey dressings would make this a valuable addition to the dressing currently available in the primary care setting. An evaluation was undertaken involving 20 patients with a variety of wounds. A conclusion is drawn that while further research is needed, medical grade honey does appear to be a valuable addition to the wound management formulary.
Effects of wound dressings on cultured primary keratinocytes.
Esteban-Vives, Roger; Young, Matthew T; Ziembicki, Jenny; Corcos, Alain; Gerlach, Jörg C
2016-02-01
Autologous cell-spray grafting of non-cultured epidermal cells is an innovative approach for the treatment of severe second-degree burns. After treatment, wounds are covered with dressings that are widely used in wound care management; however, little is known about the effects of wound dressings on individually isolated cells. The sprayed cells have to actively attach, spread, proliferate, and migrate in the wound for successful re-epithelialization, during the healing process. It is expected that exposure to wound dressing material might interfere with cell survival, attachment, and expansion. Two experiments were performed to determine whether some dressing materials have a negative impact during the early phases of wound healing. In one experiment, freshly isolated cells were seeded and cultured for one week in combination with eight different wound dressings used during burn care. Cells, which were seeded and cultured with samples of Adaptic(®), Xeroform(®), EZ Derm(®), and Mepilex(®) did not attach, nor did they survive during the first week. Mepitel(®), N-Terface(®), Polyskin(®), and Biobrane(®) dressing samples had no negative effect on cell attachment and cell growth when compared to the controls. In a second experiment, the same dressings were exposed to pre-cultured cells in order to exclude the effects of attachment and spreading. The results confirm the above findings. This study could be of interest for establishing skin cell grafting therapies in burn medicine and also for wound care in general. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Efficacy of a surfactant-based wound dressing on biofilm control.
Percival, Steven L; Mayer, Dieter; Salisbury, Anne-Marie
2017-09-01
The aim of this study was to evaluate the efficacy of both a nonantimicrobial and antimicrobial (1% silver sulfadiazine-SSD) surfactant-based wound dressing in the control of Pseudomonas aeruginosa, Enterococcus sp, Staphylococcus epidermidis, Staphylococcus aureus, and methicillin-resistant S. aureus (MRSA) biofilms. Anti-biofilm efficacy was evaluated in numerous adapted American Standards for Testing and Materials (ASTM) standard biofilm models and other bespoke biofilm models. The ASTM standard models employed included the Minimum biofilm eradication concentration (MBEC) biofilm model (ASTM E2799) and the Centers for Disease Control (CDC) biofilm reactor model (ASTM 2871). Such bespoke biofilm models included the filter biofilm model and the chamberslide biofilm model. Results showed complete kill of microorganisms within a biofilm using the antimicrobial surfactant-based wound dressing. Interestingly, the nonantimicrobial surfactant-based dressing could disrupt existing biofilms by causing biofilm detachment. Prior to biofilm detachment, we demonstrated, using confocal laser scanning microscopy (CLSM), the dispersive effect of the nonantimicrobial surfactant-based wound dressing on the biofilm within 10 minutes of treatment. Furthermore, the non-antimicrobial surfactant-based wound dressing caused an increase in microbial flocculation/aggregation, important for microbial concentration. In conclusion, this nonantimicrobial surfactant-based wound dressing leads to the effective detachment and dispersion of in vitro biofilms. The use of surfactant-based wound dressings in a clinical setting may help to disrupt existing biofilm from wound tissue and may increase the action of antimicrobial treatment. © 2017 by the Wound Healing Society.
N-Halamine Biocidal Materials with Superior Antimicrobial Efficacies for Wound Dressings.
Demir, Buket; Broughton, Roy M; Qiao, Mingyu; Huang, Tung-Shi; Worley, S D
2017-09-21
This work demonstrated the successful application of N-halamine technology for wound dressings rendered antimicrobial by facile and inexpensive processes. Four N-halamine compounds, which possess different functional groups and chemistry, were synthesized. The N-halamine compounds, which contained oxidative chlorine, the source of antimicrobial activity, were impregnated into or coated onto standard non-antimicrobial wound dressings. N-halamine-employed wound dressings inactivated about 6 to 7 logs of Staphylococcus aureus and Pseudomonas aeruginosa bacteria in brief periods of contact time. Moreover, the N-halamine-modified wound dressings showed superior antimicrobial efficacies when compared to commercially available silver wound dressings. Zone of inhibition tests revealed that there was no significant leaching of the oxidative chlorine from the materials, and inactivation of bacteria occurred by direct contact. Shelf life stability tests showed that the dressings were stable to loss of oxidative chlorine when they were stored for 6 months in dark environmental conditions. They also remained stable under florescent lighting for up to 2 months of storage. They could be stored in opaque packaging to improve their shelf life stabilities. In vitro skin irritation testing was performed using a three-dimensional human reconstructed tissue model (EpiDerm™). No potential skin irritation was observed. In vitro cytocompatibility was also evaluated. These results indicate that N-halamine wound dressings potentially can be employed to prevent infections, while at the same time improving the healing process by eliminating undesired bacterial growth.
Dressing wear time after breast reconstruction: study protocol for a randomized controlled trial
2013-01-01
Background One of the major risk variables for surgical site infection is wound management. Understanding infection risk factors for breast operations is essential in order to develop infection-prevention strategies and improve surgical outcomes. The aim of this trial is to assess the influence of dressing wear time on surgical site infection rates and skin colonization. Patients’ perception at self-assessment will also be analyzed. Methods/Design This is a two-arm randomized controlled trial. Two hundred breast cancer patients undergoing immediate or delayed breast reconstruction will be prospectively enrolled. Patients will be randomly allocated to group I (dressing removed on postoperative day one) or group II (dressing removed on postoperative day six). Surgical site infections will be defined by standard criteria from the Centers for Disease Control and Prevention (CDC). Skin colonization will be assessed by culture of samples collected at predefined time points. Patients will score dressing wear time with regard to safety, comfort and convenience. Discussion The evidence to support dressing standards for breast surgery wounds is empiric and scarce. CDC recommends protecting, with a sterile dressing for 24 to 48 hours postoperatively, a primarily closed incision, but there is no recommendation to cover this kind of incision beyond 48 hours, or on the appropriate time to shower or bathe with an uncovered incision. The results of the ongoing trial may support standard recommendations regarding dressing wear time after breast reconstruction. Trial registration ClinicalTrials.gov identifier: http://NCT01148823. PMID:23432779
Jin, Sung Giu; Yousaf, Abid Mehmood; Kim, Kyeong Soo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jin Ki; Yong, Chul Soon; Youn, Yu Seok; Kim, Jong Oh; Choi, Han-Gon
2016-03-30
The purpose of this study was to investigate the influence of different hydrophilic polymers on the swelling, bioadhesion and mechanical strength of hydrocolloid wound dressings (HCDs) in order to provide an appropriate composition for a hydrocolloid wound dressing system. In this study, the HCDs were prepared with styrene-isoprene-styrene copolymer (SIS) and polyisobutylene (PIB) as the base using a hot melting method. Additionally, numerous SIS/PIB-based HCDs were prepared with six hydrophilic polymers, and their wound dressing properties were assessed. Finally, the wound healing efficacy of the selected formulations was compared to a commercial wound dressing. The swelling ratio, bioadhesive force and mechanical strengths of HCDs were increased in the order of sodium alginate>sodium CMC=poloxamer=HPMC>PVA=PVP, sodium alginate>sodium CMC=poloxamer>PVA>HPMC=PVP and sodium alginate≥PVA>PVP=HPMC=sodium CMC>poloxamer, respectively. Among the hydrophilic polymers tested, sodium alginate most enhanced the swelling capacity, bioadhesive force and mechanical strengths. Thus, the hydrophilic polymers played great role in the swelling, bioadhesion and mechanical strength of SIS/PIB-based HCDs. The HCD formulation composed of PIB, SIS, liquid paraffin and sodium alginate at the weight ratio of 20/25/12/43 gave better wound dressing properties and more excellent wound healing efficacy than the commercial wound dressing. Therefore, the novel HCD formulation could be a promising hydrocolloid system for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
A Wireless Electroceutical Dressing Lowers Cost of Negative Pressure Wound Therapy
Ghatak, Piya Das; Schlanger, Richard; Ganesh, Kasturi; Lambert, Lynn; Gordillo, Gayle M.; Martinsek, Patsy; Roy, Sashwati
2015-01-01
Objective: To test whether the use of a wireless electroceutical dressing (WED) (Procellera®) in conjunction with a 5-day negative pressure wound therapy (NPWT) may reduce the number of dressing changes required per week with this therapy. Approach: At the Ohio State University Comprehensive Wound Center, chronic wound patients (n=30) undergoing NPWT were randomized into two arms following consent as approved by the institutional review board. The control arm received standard of care NPWT, where the dressing change was performed thrice a week. The test arm received the same care except that the WED was added as an interface layer and dressing change was limited to twice a week. Results: A reduced cost of care was achieved using the WED in conjunction with NPWT. Despite fewer dressing changes in wounds dressed with the WED, closure outcomes were comparable with no overt signs of any wound complication, including infection. The cost of NPWT care during the week was significantly lower (from $2918 to $2346) in the WED-treated group compared with patients in the control arm. Innovation: This work introduces a novel technology platform involving a WED, which may be used in conjunction with NPWT. If used as such, NPWT is effective in decreasing the frequency of dressing change and lowering the cost of care. Conclusion: This work points toward the benefit of using the WED combined with NPWT. A larger clinical trial investigating the cost-effectiveness of WED in wound care is warranted. PMID:26005596
DEVELOPMENT OF A NEXT-GENERATION ANTIMICROBIAL WOUND DRESSING.
Metcalf, Daniel; Parsons, David; Bowler, I Philip
2016-03-01
Delayed wound healing due to infection is a burden on healthcare systems, and the patient and caregiver alike. An emerging factor in infection and delayed healing is the presence development of biofilm in wounds. Biofilm is communities of microorganisms, protected by an extracellular matrix of slime in the wound, which can tolerate host defences and applied antimicrobials such as antibiotics or antimicrobial dressings. A growing evidence base exists suggesting that biofilm exists in a majority of chronic wounds, and can be a precursor to infection while causing delayed healing itself. In vivo models have demonstrated that the inflammatory, granulation and epithelialization processes of normal wound healing are impaired by biofilm presence. The challenge in the development of a new antimicrobial wound dressing was to make standard antimicrobial agents more effective against biofilm, and this was answered following extensive biofilm research and testing. A combination of metal chelator, surfactant and pH control displayed highly synergistic anti-biofilm action with 1.2% ionic silver in a carboxymethylcellulose dressing. Its effectiveness was challenged and proven in complex in vitro and in vivo wound biofilm models, followed by clinical safety and performance demonstrations in a 42-patient study and 113 clinical evaluations. Post-market surveillance was conducted on the commercially available dressing, and in a 112-case evaluation, the dressing was shown to effectively manage exudate and suspected biofilm while shifting difficult-to-heal wounds onto healing trajectories, after an average of 4 weeks of new dressing use in otherwise standard wound care protocols. This was accompanied by a low frequency of dressing related adverse events. In a second evaluation, clinical signs of infection and wound dimension data, before and after the evaluations, were also available. Following an average of 5.4 weeks of dressing use, all signs of clinical infection were reduced, from an average frequency of 36% to 21%. An average of 62% wound size reduction was achieved, with 90% of wounds reducing in size and 10 wounds healing completely. The new clinical evidence for this next-generation antimicrobial wound dressing suggests it is safe and effective at managing exudate, infection and biofilm, while it can shift established, stubborn wounds onto healing trajectories. The scientific rationale for this new dressing technology is supported by in vitro and in vivo evidence, so now further comparative, randomized and outcome-based clinical studies are required to fully understand the clinical and economic benefits this new dressing technology can bring.
Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.
Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M
2015-07-01
Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.
Naruse, Koji; Uchino, Masataka; Hirakawa, Noriko; Toyama, Masahiro; Miyajima, Genyo; Mukai, Manabu; Urabe, Ken; Uchida, Kentaro; Itoman, Moritoshi
2016-08-01
We have conducted a basic study on the influences on ultrasonic properties when LIPUS is applied through wound dressing. According to the results of ex vivo experiments conducted to date, LIPUS showed ultrasonic properties such as transmittance, coefficient of transmission, and a non-uniformity ratio through film wound dressing better than other wound dressing, and it was considered that LIPUS's effect for fracture healing was not influenced by film wound dressing. Then, we discussed the influence on the effect of LIPUS through film wound dressing. Thirty male 8-week-old Sprague-Dawley rats were used for the trial. After creating close transverse femoral fractures on the right legs of these 30 rats, they were divided into 3 groups of 10; LIPUS through wound dressing (Group A), LIPUS without wound dressing (Group B), and No LIPUS treatment (Group C). OPSITE Wound, which was thought to have the least influence on ultrasound properties, was used for this trial. Group A and B received LIPUS for 20 minutes a day from the first day after the fractures. LIPUS was generated from Teijin Pharma's device for a basic experiment. When treating Group A, the wound dressing was pasted on the ultrasound terminal in order to apply LIPUS through the dressing. We assessed the time-oriented morphological change of each group in anesthetized condition using simple radiographs on the 8th, 16th, and 24th day after the fractures. Six rats in Group A, 2 in Group B, and 1 in Group C died in anesthesia, and we discussed the remaining 4 rats in Group A, 8 in Group B, and 9 in Group C. We defined more than one teleost callus bridging as bone-union. We also counted a bone remodeling when we recognized the absorption of existing cortical bone and the transformation of new bone to cortical bone in simple radiographs. As a result, compared with Group C, we recognized that both bone union and remodeling accelerated remarkably in Group B, but not in Group A. It suggested that LIPUS through wound dressing had negative influences on both period shorting of fracture healing and bone remodeling. When LIPUS was conducted through film wound dressing, transmittance and coefficient of transmission were unchanged; however, the non-uniformity ratio changed slightly. The non-uniformity ratio of the ultrasound transducer had a significant influence on the effect of LIPUS on fracture healing.
Professional Characteristics Communicated by Formal versus Casual Workplace Attire
ERIC Educational Resources Information Center
Cardon, Peter W.; Okoro, Ephraim A.
2009-01-01
Employees are frequently advised to dress for success to build their careers. From the corporate perspective, employees who are well dressed are believed to form better impressions with colleagues, clients, and customers. Many companies create dress codes in order to gain the benefits of a professionally appearing workforce. Developing effective…
Identification of Workplace Dress by Low-Income Job Seekers
ERIC Educational Resources Information Center
Saiki, Diana
2013-01-01
The author examined how low-income job seekers participating in a workplace dress program identified traditional business and business casual dress. Seventy low-income job seekers identified clothing items as traditional business (e.g., suits, ties), similar to identifications made by professionals and image consultants in previous literature.…
ERIC Educational Resources Information Center
Lumsden, Linda; Miller, Gabriel
2002-01-01
Students do not always make choices that adults agree with in their choice of school dress. Dress-code issues are explored in this Research Roundup, and guidance is offered to principals seeking to maintain a positive school climate. In "Do School Uniforms Fit?" Kerry White discusses arguments for and against school uniforms and summarizes the…
Counterconformity: An Attribution Model of Adolescents' Uniqueness-Seeking Behaviors in Dressing
ERIC Educational Resources Information Center
Ling, I-Ling
2008-01-01
This article explores how an attribution model will illustrate uniqueness-seeking behavior in dressing in the Taiwanese adolescent subculture. The study employed 443 senior high school students. Results show that the tendency of uniqueness-seeking behavior in dressing is moderate. However, using cluster analysis to segment the counterconformity…
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
9 CFR 108.9 - Dressing rooms and other facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dressing rooms and other facilities. 108.9 Section 108.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... REQUIREMENTS FOR LICENSED ESTABLISHMENTS § 108.9 Dressing rooms and other facilities. Each licensed...
2003-09-01
Pharmaceuticals, Inc. (Westlake, OH), submitted the Hemarrest dressing. This dressing was a thin, sheet-like pad with a mixture of epsilon aminocaproic acid ...chloric acid salt purified bovine corium collagen. It was prepared in a compacted nonwoven web form (7.0 7.0 cm). Ethicon, Inc. (Somerville, NJ...may be related to enhanced platelet procoagulant activity and annexin V binding.46 Another derivative of gallic acid , bis- muth subgallate, appears to
An evaluation of a silicone adhesive shaped heel dressing.
Hampton, Sylvie
Tissue breakdown is complex and involves many factors. Pressure ulcer development in the heels is subject to extrinsic factors such as pressure, shear, friction and moisture. The heels are the most common sites for friction and shear damage, which can lead to blistering, skin erosion and tissue breakdown (Grey et al, 2006). To address the issues of wounds that are painful on dressing removal and friable skin, Smith & Nephew has introduced a soft silicone adhesive dressing to its Allevyn dressing range. Silicone does not adhere to wounded areas and can be removed gently without trauma to the periwound area. This paper discusses the findings of a 20-patient multi-site evaluation examining the performance and acceptability of Allevyn Gentle Border Heel dressing in the management of heel wounds.
The use of prophylactic dressings in the prevention of pressure ulcers: a literature review.
Cornish, Lynn
2017-06-02
Pressure ulcers pose a significant burden to both patients and health care resources. There are an increasing number of studies that have examined the use of prophylactic dressings, and their ability to redistribute pressure and protect the skin from shear and friction damage. This literature review examines six studies conducted on this controversial subject. Brindle and Wegelin ( 2012 ; Chaiken, 2012 ; Cubit et al, 2012 ; Santamaria et al, 2012) all examined the role of dressings to prevent pressure ulcers, and Call et al (2013a ; 2013b ), conducted in vitro research into the mode of dressings. Current research suggests that while further research is required, the use of prophylactic dressings have a place alongside standard measures, in helping to prevent pressure, shear and friction damage.
Wound dressings from naturally-occurring polymers: A review on homopolysaccharide-based composites.
Naseri-Nosar, Mahdi; Ziora, Zyta Maria
2018-06-01
Wound dressings are designed to support the wound bed and protect it from the factors that may delay or impede its healing such as contaminations and moisture-loss, thereby facilitating and accelerating the healing process. The materials used to prepare wound dressings include natural and synthetic polymers, as well as their combinations, in the forms of films, sponges and hydrogels. Polysaccharides are naturally-occurring polymers that have been extensively used as wound dressing materials. Homopolysaccharides are a class of polysaccharides consist of only one type of monosaccharide. The current review intends to overview the studies in which wound dressings from naturally-occurring polymers, based on homopolysaccharides, were prepared and evaluated. Homopolysaccharides such as cellulose, chitosan, chitin, pullulan, starch and β-glucan were considered. Copyright © 2018 Elsevier Ltd. All rights reserved.
She Wears the Pants: The Reform Dress as Technology in Nineteenth-Century America.
Mas, Catherine
This article examines the American dress-reform movement, detailing the ways in which reformers conceptualized clothing as a social and bodily technology. In the mid-nineteenth century, women began making and wearing the "reform dress"-a costume consisting of pants and shortened, lightweight skirts-as an alternative to burdensome feminine fashions. When ridiculed in public for wearing overtly masculine garments, dress reformers insisted their clothing was healthful, functional, and natural. This article discusses women's use of medical science and technical knowledge in their rejection of fashion, promotion of sexual equality, and efforts to change mainstream clothing practices. When approached from a technological perspective, the reform dress reveals broader tensions in an industrializing American society, such as changing gender relations and new understandings of the relationship between humans and technology.
Dabiri, Ganary; Hammerman, Scott; Falanga, Vincent
2014-01-01
Venous leg ulcers affect millions of patients worldwide and are a tremendous financial burden on our healthcare system. The hallmark of venous disease of the lower extremities is venous hypertension, and compression is the current mainstay of treatment. However, many patients are noncompliant, in part because of the complexity of the dressings and the difficulties with application and removal. The aim of our study was to determine an effective compression dressing regimen for patients with venous leg ulcers who require changing the ulcer primary dressing twice daily. We used two layers of a latex free tubular elastic bandage for compression. The primary endpoint of our study was increased wound healing rate and our secondary endpoint was complete wound closure. All active study subjects had positive healing rates at week 4 and week 8. Two subjects achieved complete wound closure by week 8. We conclude that compression with a latex-free tubular elastic bandage can be safely used in patients with venous leg ulcers requiring frequent dressing changes. This type of compression allows for daily inspection of wounds, dressing changes at home, flexibility in the context of clinical trials, and is a compromise for patients that are intolerant to compression dressings. PMID:24267477
Effect of music intervention on burn patients' pain and anxiety during dressing changes.
Hsu, Kuo-Cheng; Chen, Li Fen; Hsiep, Pi Hsia
2016-12-01
For burn patients, the daily dressing process causes pain and anxiety. Although drugs can relieve them, the degree of pain during dressing changes is often moderate to severe. Therefore, relevant supporting interventions, like music as an ideal intervention, could alleviate the patient's pain. This study investigated the impact of music intervention at dressing change time on burn patients' pain and anxiety. This was a prospective, randomized clinical trial; patients were randomly assigned into control (standard intervention) and experimental groups (crystal music intervention) for five consecutive days (35 patients in each group). Patients' pain and anxiety measurements were collected before, during, and after dressing changes and morphine usage was recorded. The study period was October 2014 to September 2015. There was no difference in morphine dosage for both groups. By the fourth day of music intervention, burn patients' pain before, during, and after dressing changes had significantly decreased; anxiety on the fourth day during and after dressing changes had also significantly decreased. Nurses may use ordered prescription analgesics, but if non-pharmacological interventions are increased, such as providing timely music intervention and creating a friendly, comfortable hospital environment, patients' pain and anxiety will reduce. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Cattelan, Marília Gonçalves; Nishiyama, Yara Paula de Oliveira; Gonçalves, Tânia Maria Vinturim; Coelho, Alexandre Rodrigo
2018-08-01
There is a broad research interest in the search for alternatives to chemical additives for use as natural food preservatives. Although many natural compounds have biological in vitro properties evidenced, in situ studies are still scarce. This study evaluated the effect of oregano essential oil (OEO) and salt (NaCl) concentrations against Escherichia coli (ATCC 8739), in salad dressing, using the response surface methodology. The experiment included a 2 2 central composite rotatable design (CCRD) in a total of 11 formulations of salad dressings. Oregano essential oil was characterized by gas chromatography and salad dressings by ash, lipids, proteins and moisture. OEO was composed mainly by carvacrol (65.1%) and p-cymene (12.0%). Salad dressings showed similar chemical profiles. A mathematical model for the prediction of the antibacterial activity in salad dressing was obtained. The results revealed that the interaction between OEO and salt showed effect on the bacterial count. However, the effect of salt was negative suggesting that the highest NaCl concentrations decreases the bacterial count. Therefore, within the parameters studied, the use of OEO to control E. coli in salad dressing can be considered promising and allows reduction in the levels of salt to be incorporated in food. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sahraro, Maryam; Yeganeh, Hamid; Sorayya, Marziyeh
2016-02-01
Preparation and assessments of novel absorptive wound dressing materials with efficient antimicrobial activity as well as very good cytocompatibility were described in this work. An amine terminated poly(hexamethylene guanidine hydrochloride) was prepared and used as curing agent of different epoxy-terminated polyurethane prepolymers. The structures of prepared materials were elucidated by evaluation of their (1)H NMR and FTIR spectra. The recorded tensile strength of membranes confirmed the excellent dimensional stability of the film type dressings even at fully hydrated conditions. Therefore, these dressings could protect the wound bed from external forces during the healing period. The structurally optimized dressing membranes could preserve the desired moist environment over the wounded area, as a result of their balanced equilibrium, water absorption and water vapor transmission rate. Therefore, a very good condition for stimulation of self-healing of wound bed was attained. Also, owing to the presence of guanidine hydrochloride moieties embedded into the structure of dressings, efficient antimicrobial activity against Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans were detected. In vitro cytotoxicity assay of the prepared dressings revealed cytocompatibility of these materials against fibroblast cells. Therefore, they could support cell growth and proliferation at the wounded area. Copyright © 2015 Elsevier B.V. All rights reserved.
Fontaine, Mathieu; Latarjet, Jacques; Payre, Jacqueline; Poupelin, Jean-Charles; Ravat, François
2017-03-01
The severe pain related to repeated burn dressing changes at bedside is often difficult to manage. However these dressings can be performed at bedside on spontaneously breathing non-intubated patients using powerful intravenous opioids with a quick onset and a short duration of action such as alfentanil. The purpose of this study is to demonstrate the efficacy and safety of the protocol which is used in our burn unit for pain control during burn dressing changes. Cohort study began after favorable opinion from local ethic committee has been collected. Patient's informed consent was collected. No fasting was required. Vital signs for patients were continuously monitored (non-invasive blood pressure, ECG monitoring, cutaneous oxygen saturation, respiratory rate) all over the process. Boluses of 500 (±250) mcg IV alfentanil were administered. A continuous infusion was added in case of insufficient analgesia. Adverse reactions were collected and pain intensity was measured throughout the dressing using a ten step verbal rating scale (VRS) ranging from 0 (no pain) to 10 (worst pain conceivable). 100 dressings (35 patients) were analyzed. Median age was 45 years and median burned area 10%. We observed 3 blood pressure drops, 5 oxygen desaturations (treated with stimulation without the necessity of ventilatory support) and one episode of nausea. Most of the patients (87%) were totally conscious during the dressing and 13% were awakened by verbal stimulation. Median total dose of alfentanil used was 2000μg for a median duration of 35min. Pain scores during the procedure were low or moderate (VRS mean=2.0 and maximal VRS=5). Median satisfaction collected 2h after the dressing was 10 on a ten step scale. Pain control with intravenous alfentanil alone is efficient and appears safe for most burn bedside repeated dressings in hospitalized patients. It achieves satisfactory analgesia during and after the procedure. It is now our standard analgesic method to provide repeated bedside dressings changes for burned patients. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Ampawong, Sumate; Aramwit, Pornanong
2017-09-01
In this study, three kinds of antiseptics which were 0.05% chlorhexidine, 0.2% polyhexamethylene biguanide (PHMB), or 200 ppm silver nanoparticle was introduced to incorporate in the sericin-based scaffold to produce the antimicrobial dressing for the treatment of infected chronic wound. The effects of antiseptic incorporation on the stability, release of sericin, and short-term and long-term (6 months) antimicrobial activity of the sericin dressing against gram-negative and gram-positive bacteria were investigated. We showed that the incorporation of each antiseptic did not have significant effect on the internal morphology (pore size ~ 73-105 μm), elasticity (Young's modulus ~ 200-500 kPa), and the sericin release behavior of the sericin-based dressing. The release of sericin from the dressing was prolonged over 120 h and thereafter. Comparing among three antiseptics, 0.05% chlorhexidine incorporated in the sericin dressing showed the highest immediate and long-term (6 months) antimicrobial effect (largest inhibition zone) against most bacteria either gram-positive or gram-negative bacteria. The in vivo safety test following ISO10993 standard (Biological evaluation of medical devices - Part 6: Tests for local effects after implantation) confirmed that the sericin dressing incorporating 0.05% chlorhexidine did not irritate to tissue, comparing with the commercial material used generally in clinic (Allevyn®, Smith & Nephew). We suggested the sericin dressing incorporating 0.05% chlorhexidine for the treatment of infected chronic wound. Chlorhexidine would reduce the risk of infection while the sericin may promote wound healing.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief.
Prophylactic Sacral Dressing for Pressure Ulcer Prevention in High-Risk Patients.
Byrne, Jaime; Nichols, Patricia; Sroczynski, Marzena; Stelmaski, Laurie; Stetzer, Molly; Line, Cynthia; Carlin, Kristen
2016-05-01
Patients in intensive care units are likely to have limited mobility owing to hemodynamic instability and activity orders for bed rest. Bed rest is indicated because of the severity of the disease process, which often involves intubation, sedation, paralysis, surgical procedures, poor nutrition, low flow states, and poor circulation. These patients are predisposed to the development and/or the progression of pressure ulcers not only because of their underlying diseases, but also because of limited mobility and deconditioned states of health. To assess whether treating high-risk patients with a prophylactic sacral dressing decreases the incidence of unit-acquired sacral pressure ulcers. An evidence-based tool for identifying patients at high risk for pressure ulcers was used in 3 intensive care units at an urban tertiary care hospital and academic medical center. Those patients deemed at high risk had a prophylactic sacral dressing applied. Incidence rates were collected and compared for the 7 months preceding use of the dressings and for 7 months during the trial period when the dressing was used. After the sacral dressing began being used, the number of unit-acquired sacral pressure ulcers decreased by 3.4 to 7.6 per 1000 patient days depending on the unit. A prophylactic sacral dressing may help prevent unit-acquired sacral pressure ulcers. Implementation of an involved care team with heightened awareness and increased education along with a prophylactic sacral dressing in patients deemed high risk for skin breakdown are all essential for success. ©2016 American Association of Critical-Care Nurses.
NASA Astrophysics Data System (ADS)
Patil, Sanjay S.; Bhalerao, Yogesh J.
2017-02-01
Grinding is metal cutting process used for mainly finishing the automobile components. The grinding wheel performance becomes dull by using it most of times. So it should be reshaping for consistent performance. It is necessary to remove dull grains of grinding wheel which is known as dressing process. The surface finish produced on the work piece is dependent on the dressing parameters in sub-sequent grinding operation. Multi-point diamond dresser has four important parameters such as the dressing cross feed rate, dressing depth of cut, width of the diamond dresser and drag angle of the dresser. The range of cross feed rate level is from 80-100 mm/min, depth of cut varies from 10 - 30 micron, width of diamond dresser is from 0.8 - 1.10mm and drag angle is from 40o - 500, The relative closeness to ideal levels of dressing parameters are found for surface finish produced on the En-31 work piece during sub-sequent grinding operation by using Technique of Order Preference by Similarity to Ideal Solution (TOPSIS).In the present work, closeness to ideal solution i.e. levels of dressing parameters are found for Computer Numerical Control (CNC) cylindrical angular grinding machine. After the TOPSIS technique, it is found that the value of Level I is 0.9738 which gives better surface finish on the En-31 work piece in sub-sequent grinding operation which helps the user to select the correct levels (combinations) of dressing parameters.
Medical workers' cognition of using 50% nitrous oxide in children with burns: a qualitative study.
Wang, Hai-Xia; Li, Yu-Xiang; Zhou, Ru-Zhen; Zhao, Ji-Jun
2015-09-01
Pain caused by dressing among children with burns is an issue worth discussing. Medical workers' understanding of pain during dressing in children with burns is correlated with the quality of pain management. Effective pain management is significant to improve anxiety and reduce pain and psychological distress during dressing for children with burns. We aimed to investigate medical workers' understanding of current pain management during dressing among children with burns and their attitudes toward the application of 50% nitrous oxide in pain management. Interviews were conducted with seven doctors and nurses from a burn center in East China. Data were collected by in-depth interviews and qualitative description after full transcription of each interview. Three themes were identified: (1) Medical workers felt sympathy for children with burns and believed that a gap existed between the current and expected situation in pain management. In addition, the prescription of analgesics during dressing for children with burns was not favored. (2) Given the fact that 50% nitrous oxide is effective in pain management for adult patients with burns, medical workers tended to apply it to children with burns during dressing after being provided the literature on the use of 50% nitrous oxide in children. (3) Guidelines for the application of 50% nitrous oxide during dressing for children with burns require further modification. Medical workers deemed the pain management for children with burns unsatisfactory, and they supported the application of 50% nitrous oxide during dressing for children with burns. Meanwhile, they hoped that administrators would also support it. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Fontenot, Krystal R; Edwards, J Vincent; Haldane, David; Pircher, Nicole; Liebner, Falk; Condon, Brian D; Qureshi, Huzaifah; Yager, Dorne
2017-11-01
Interfacing nanocellulosic-based biosensors with chronic wound dressings for protease point of care diagnostics combines functional material properties of high specific surface area, appropriate surface charge, and hydrophilicity with biocompatibility to the wound environment. Combining a protease sensor with a dressing is consistent with the concept of an intelligent dressing, which has been a goal of wound-dressing design for more than a quarter century. We present here biosensors with a nanocellulosic transducer surface (nanocrystals, nanocellulose composites, and nanocellulosic aerogels) immobilized with a fluorescent elastase tripeptide or tetrapeptide biomolecule, which has selectivity and affinity for human neutrophil elastase present in chronic wound fluid. The specific surface area of the materials correlates with a greater loading of the elastase peptide substrate. Nitrogen adsorption and mercury intrusion studies revealed gas permeable systems with different porosities (28-98%) and pore sizes (2-50 nm, 210 µm) respectively, which influence water vapor transmission rates. A correlation between zeta potential values and the degree of protease sequestration imply that the greater the negative surface charge of the nanomaterials, the greater the sequestration of positively charged neutrophil proteases. The biosensors gave detection sensitivities of 0.015-0.13 units/ml, which are at detectable human neutrophil elastase levels present in chronic wound fluid. Thus, the physical and interactive biochemical properties of the nano-based biosensors are suitable for interfacing with protease sequestrant prototype wound dressings. A discussion of the relevance of protease sensors and cellulose nanomaterials to current chronic wound dressing design and technology is included.
Tan, Xueli; Yowler, Charles J; Super, Dennis M; Fratianne, Richard B
2010-01-01
The purpose of this study was to explore the efficacy of two music therapy protocols on pain, anxiety, and muscle tension levels during dressing changes in burn patients. Twenty-nine inpatients participated in this prospective, crossover randomized controlled trial. On two consecutive days, patients were randomized to receive music therapy services either on the first or second day of the study. On control days, they received no music. On music days, patients practiced music-based imagery (MBI), a form of music-assisted relaxation with patient-specific mental imagery before and after dressing changes. Also, on music days during dressing changes, the patients engaged in music alternate engagement (MAE), which consisted of active participation in music making. The dependent variables were the patients' subjective ratings of their pain and anxiety levels and the research nurse's objective ratings of their muscle tension levels. Two sets of data were collected before, three sets during, and another two sets after dressing changes. The results showed significant decrease in pain levels before (P < .025), during (P < .05), and after (P < .025) dressing changes on days the patients received music therapy in contrast to control days. Music therapy was also associated with a decrease in anxiety and muscle tension levels during the dressing changes (P < .05) followed by a reduction in muscle tension levels after dressing changes (P < .025). Music therapy significantly decreases the acute procedural pain, anxiety, and muscle tension levels associated with daily burn care.
#TheDress: Categorical perception of an ambiguous color image.
Lafer-Sousa, Rosa; Conway, Bevil R
2017-10-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region.
What #theDress reveals about the role of illumination priors in color perception and color constancy
Aston, Stacey; Hurlbert, Anya
2018-01-01
The disagreement between people who named #theDress (the Internet phenomenon of 2015) “blue and black” versus “white and gold” is thought to be caused by individual differences in color constancy. It is hypothesized that observers infer different incident illuminations, relying on illumination “priors” to overcome the ambiguity of the image. Different experiences may drive the formation of different illumination priors, and these may be indicated by differences in chronotype. We assess this hypothesis, asking whether matches to perceived illumination in the image and/or perceived dress colors relate to scores on the morningness-eveningness questionnaire (a measure of chronotype). We find moderate correlations between chronotype and illumination matches (morning types giving bluer illumination matches than evening types) and chronotype and dress body matches, but these are significant only at the 10% level. Further, although inferred illumination chromaticity in the image explains variation in the color matches to the dress (confirming the color constancy hypothesis), color constancy thresholds obtained using an established illumination discrimination task are not related to dress color perception. We also find achromatic settings depend on luminance, suggesting that subjective white point differences may explain the variation in dress color perception only if settings are made at individually tailored luminance levels. The results of such achromatic settings are inconsistent with their assumed correspondence to perceived illumination. Finally, our results suggest that perception and naming are disconnected, with observers reporting different color names for the dress photograph and their isolated color matches, the latter best capturing the variation in the matches. PMID:28793353
#TheDress: Categorical perception of an ambiguous color image
Lafer-Sousa, Rosa; Conway, Bevil R.
2017-01-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region. PMID:29090319
Black, Jonathan S; Drake, David B
2015-01-01
The lipid base of silver sulfadiazine (SSD) makes removal of the product painful for the patient and difficult for the physician to accurately assess particularly in partial-thickness burn injuries. As an alternative, a water-soluble antimicrobial gel is used at the University of Virginia. We present a prospective, randomized comparison of these two therapies using pain with dressing changes and time to perform dressing changes as our primary endpoints. Adult inpatients with partial-thickness burn wounds were randomized to begin therapy with either SSD cream or the water-soluble burn wound gel (BWG), and then therapies were alternated daily. Pain assessments, time to complete dressing care, total narcotic medication administered, and the number of personnel required for dressing changes were recorded. Eight patients were enrolled resulting in 13 pairs (26 points) of data comparison between the two therapies. Four of the eight enrolled patients (50%) refused to continue receiving SSD because of pain associated with dressing changes and voluntarily withdrew from the study. The amount of time to perform dressing changes was an average of 79 nurse-minutes longer for SSD. A 6.08 greater morphine equivalent was delivered to those having BWG removed.A water-soluble polyantimicrobial gel was superior to SSD in the parameters measured as exhibited by our patient dropout rate and differential time to perform dressing care. Limiting the time to perform dressing care will reduce the cumulative pain experience, improve patient satisfaction, and reduce the resources to deliver care.
Fashion as Argument: Nineteenth-Century Dress Reform.
ERIC Educational Resources Information Center
Torrens, Kathleen M.
1999-01-01
Examines the place of the body in the dress-reform movement, a social movement that focused on fashion as a vehicle for achieving social and political equality. Discusses how fashion became one arena in which definitions of gender were contested. Suggests the dress-reform movement's failure in redefining femininity indicates the depth of…
ERIC Educational Resources Information Center
Chatelain, Amber M.
2015-01-01
This study sought to discover student perceptions of academics' dress and gender and their impact on perceived instructor approachability and likeability. Three categories of dress were examined: casual, business casual and professional. The results of this study suggest students at career-arts institutions perceive female teachers as less…
ERIC Educational Resources Information Center
Freeburg, Beth Winfrey; Workman, Jane E.
2010-01-01
The purpose of this study was to explore teacher dress in United States schools as presented in the newspaper. Twenty-nine articles were examined to answer three questions. Results revealed: (a) the newspaper provided four contexts for processing information about teacher dress--roles, control, impression management, and educational learning…
Dress-Related Responses to the Columbine Shootings: Other-Imposed and Self-Designed.
ERIC Educational Resources Information Center
Ogle, Jennifer Paff; Eckman, Molly
2002-01-01
An inductive content analysis approach was used to examine 155 dress-related newspaper articles following the Columbine High School shootings in 1999. Analysis revealed two dress-related responses: (1) other-imposed regulation to protect students and deter them from expressing hatred and (2) self-designed acts of resistance for grieving. (Contains…
ERIC Educational Resources Information Center
Morris, Tracy L.; And Others
1996-01-01
Finds that more formal dress (business suits, dress shoes) was associated with increased ratings of teaching assistants' competence, particularly for female students rating female instructors. Shows, however, that contrary to common assumptions, the most positive influences of instructor dress were found in the highly casual condition (faded…
Effect of Andrographis paniculata leaf extract on wound healing in rats.
Al-Bayaty, Fouad Hussain; Abdulla, Mahmood Ameen; Abu Hassan, Mohamed Ibrahim; Ali, Hapipah Mohd
2012-01-01
This work was carried out to study the effect of topical application of Andrographis paniculata on the rate of wound enclosure and its histological features. A wound was created in four groups of rat in posterior neck region. Blank placebo was applied topically to the wounds of Group 1. Groups 2 and 3 were dressed with placebo containing 5% and 10% extracts of A. paniculata, respectively. Intrasite gel was applied topically to the wounds of Group 4. Macroscopical examination revealed that the rate of wound healing was significantly accelerated in the wound dressed with A. paniculata extract compared to the blank placebo. The wounds dressed with 10% extract or Intrasite gel healed earlier compared to the wounds dressed with placebo containing 5% A. paniculata extract. Histologically, wounds dressed with A. paniculata extracts showed markedly less scar width and contained large amounts of fibroblast proliferation. More collagen and less angiogenesis with absence of inflammatory cells were seen for wounds dressed with 10% A. paniculata compared to the blank placebo. Conclusion, A. paniculata extracts significantly enhanced rate of wound healing in rats.
An in vitro test of the efficacy of an anti-biofilm wound dressing.
Said, Jawal; Walker, Michael; Parsons, David; Stapleton, Paul; Beezer, Anthony E; Gaisford, Simon
2014-10-20
Broad-spectrum antimicrobial agents, such as silver, are increasingly being formulated into medicated wound dressings in order to control colonization of wounds by opportunistic pathogens. Medicated wound dressings have been shown in-vitro to be effective against planktonic cultures, but in-vivo bacteria are likely to be present in biofilms, which makes their control and eradication more challenging. Recently, a functional wound dressing (AQUACEL(®) Ag+ Extra™ (AAg + E)) has been developed that in addition to silver contains two agents (ethylenediaminetetraacetic acid (EDTA) and benzethonium chloride (BC)) designed to disrupt biofilms. Here, the efficacy of AAg + E is demonstrated using a biofilm model developed in an isothermal microcalorimeter. The biofilm was seen to remain viable in the presence of unmedicated dressing, silver-containing dressing or silver nitrate solution. In the presence of AAg + E, however, the biofilm was eradicated. Control experiments showed that neither EDTA nor BC alone had a bactericidal effect, which means it is the synergistic action of EDTA and BC disrupting the biofilm with silver being bactericidal that leads to the product's efficacy. Copyright © 2014 Elsevier B.V. All rights reserved.
Mitchell, Michael S; Koen, Clifford M; Moore, Thomas W
2013-01-01
As more and more individuals choose to express themselves and their religious beliefs with headwear, jewelry, dress, tattoos, and body piercings and push the envelope on what is deemed appropriate in the workplace, employers have an increased need for creation and enforcement of reasonable dress codes and appearance policies. As with any employment policy or practice, an appearance policy must be implemented and enforced without regard to an individual's race, color, sex, national origin, religion, disability, age, or any other protected status. A policy governing dress and appearance based on the business needs of an employer that is applied fairly and consistently and does not have a disproportionate effect on any protected class will generally be upheld if challenged in court. By examining some of the more common legal challenges to dress codes and how courts have resolved the disputes, health care managers can avoid many potential problems. This article addresses the issue of religious discrimination focusing on dress and appearance and some of the court cases that provide guidance for employers.
Dispersive detection of radio-frequency-dressed states
NASA Astrophysics Data System (ADS)
Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas
2018-04-01
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
The effect of semirigid dressings on below-knee amputations.
MacLean, N; Fick, G H
1994-07-01
The effect of using semirigid dressings (SRDs) on the residual limb of individuals who have had below-knee amputations as a consequence of peripheral vascular disease was investigated, with the primary question being: Does the time to readiness for prosthetic fitting for patients treated with the SRDs differ from that of patients treated with soft dressings? Forty patients entered the study and were alternately assigned to one of two groups. Nineteen patients were assigned to the SRD group, and 21 patients were assigned to the soft dressing group. The time from surgery to readiness for prosthetic fitting was recorded for each patient. Kaplan-Meier survival curves were generated for each group, and the results were analyzed with the log-rank test. There was a difference between the two curves, and an examination of the curves suggests that the expected time to readiness for prosthetic fitting for patients treated with the SRDs would be less than half that of patients treated with soft dressings. The results suggest that a patient may be ready for prosthetic fitting sooner if treated with SRDs instead of soft dressings.
Günal, Özgür; Tuncel, Umut; Turan, Aydin; Barut, Sener; Kostakoglu, Naci
2015-10-01
The aim of this retrospective study was to evaluate the efficacy of vacuum-assisted closure (VAC) and GranuFoam Silver® dressing (KCI, San Antonio, TX) compared with conventional GranuFoam® dressing in the management of diabetic foot ulcers. Twenty-one consecutive patients treated with conventional or silver-coated foam dressing were reviewed retrospectively. The wound duration was 6 mo. Group 1 (n=10) received conventional foam dressing (GranuFoam) and group 2 (n=11) received silver-coated foam dressing (GranuFoam Silver). The wound surface area, duration of treatment, bacteriology, and recurrence were compared between the groups. The mean age of the patients was 61.70±10.52 y in group 1 and 67.27±11.28 y in group 2. In group 1, the average surface area of the wounds was 45.30±46.96 cm2 and 18.40±23.48 cm2 in the pre-treatment and post-treatment periods, respectively. There was a statistically significant difference between two measurements (p=0.005). Average duration of the treatment was 25.50±27.13 d in this group. In group 2, average surface area of the wounds in the pre-treatment and post-treatment periods were 41.55±36.03 cm2 and 7.64±3.91 cm2, respectively. There was a statistically significant difference between two measurements (p=0.003). Average duration of the treatment was 10.09±3.51 d in this group. The patients treated with silver-impregnated polyurethane foam dressing had reduced recurrence (2 vs. 7 wounds, p=0.030) and increased number of the culture-negative cases at the end of the treatment. With the results of the study, it was concluded that VAC GranuFoam silver dressing can be superior to conventional GranuFoam dressing in reducing the recurrence rate of infected diabetic foot ulcers.
Heyneman, A; Hoeksema, H; Vandekerckhove, D; Pirayesh, A; Monstrey, S
2016-11-01
For more than 40 years, silver sulphadiazine 1% (SSD) is considered as standard therapy for the conservative treatment of burn wounds. However, in the last 10 years, substantial disadvantages of SSD have been reported in the literature and probably as a result of this, several new dressings for burn wounds have been developed and put on the market. The objective of this systematic review is to evaluate the available evidence on SSD in the conservative treatment of burns, specifically in comparison with the newer burn dressings that are increasingly being used nowadays. A search filter was composed to select randomized controlled trials (RCTs) from the MEDLINE database. Only RCTs studying the effect of conservative treatment on burns were selected. At least one of the two comparative groups was treated with SSD. Each included article was analysed and relevant data (baseline parameters, interventions, outcomes and methodological parameters) were registered using Microsoft Office Excel 2007. Many dressings showed superior healing properties compared to SSD, but no dressing was able to show a clear benefit over SSD regarding infection. The number of dressing changes, pain and patient's satisfaction are more favourable in the newer dressings, especially with solid and biological dressings. The results of this systematic review clearly demonstrate that a faster wound healing is obtained with the newly developed burn dressings. Additionally, these new dressings tend to be more comfortable for the patients and easier to use for care givers. The minor differences in antibacterial activity between SSD and the new products did not seem to have any influence on the rate of wound healing. Since rapid wound closure is essential to obtain an optimal functional and aesthetic outcome, it can be concluded from the results of this systemic review that the standard use of SSD in the conservative treatment of burn wounds can no longer be supported. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
AdS/CFT duality at strong coupling
NASA Astrophysics Data System (ADS)
Beccaria, M.; Ortix, C.
2007-08-01
We study the strong-coupling limit of the AdS/CFT correspondence in the framework of a recently proposed fermionic formulation of the Bethe ansatz equations governing the gauge theory anomalous dimensions. We give examples of states that do not follow the Gubser-Klebanov-Polyakov law at a large ’t Hooft coupling λ, in contrast to recent results on the quantum string Bethe equations that are valid in that regime. This result indicates that the fermionic construction cannot be trusted at large λ, although it remains an efficient tool for computing the weak-coupling expansion of anomalous dimensions.
Dynamical Casimir-Polder force on a partially dressed atom near a conducting wall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messina, Riccardo; Vasile, Ruggero; Passante, Roberto
2010-12-15
We study the time evolution of the Casimir-Polder force acting on a neutral atom in front of a perfectly conducting plate, when the system starts its unitary evolution from a partially dressed state. We solve the Heisenberg equations for both atomic and field quantum operators, exploiting a series expansion with respect to the electric charge and an iterative technique. After discussing the behavior of the time-dependent force on an initially partially dressed atom, we analyze a possible experimental scheme to prepare the partially dressed state and the observability of this new dynamical effect.
Hasatsri, Sukhontha; Angspatt, Apichai
2015-01-01
We developed the novel silk fibroin-based bilayered wound dressing for the treatment of partial thickness wounds. And it showed relevant characteristics and accelerated the healing of full-thickness wounds in a rat model. This study is the clinical evaluation of the bilayered wound dressing to confirm its safety and efficacy for the treatment of split-thickness skin donor sites. The safety test was performed using a patch model and no evidence of marked and severe cutaneous reactions was found. The efficacy test of the bilayered wound dressing was conducted on 23 patients with 30 split-thickness skin graft donor sites to evaluate healing time, pain score, skin barrier function, and systemic reaction in comparison to Bactigras. We found that the healing time of donor site wounds treated with the bilayered wound dressing (11 ± 6 days) was significantly faster than those treated with Bactigras (14 ± 6 days) (p = 10−6). The wound sites treated with the bilayered wound dressing showed significantly less pain and more rapid skin functional barrier recovery than those treated with Bactigras (p = 10−5). Therefore, these results confirmed the clinical safety and efficacy of the bilayered wound dressing for the treatment of split-thickness skin graft donor sites. PMID:26221170
Economic impact of Tegaderm chlorhexidine gluconate (CHG) dressing in critically ill patients.
Thokala, Praveen; Arrowsmith, Martin; Poku, Edith; Martyn-St James, Marissa; Anderson, Jeff; Foster, Steve; Elliott, Tom; Whitehouse, Tony
2016-09-01
To estimate the economic impact of a Tegaderm TM chlorhexidine gluconate (CHG) gel dressing compared with a standard intravenous (i.v.) dressing (defined as non-antimicrobial transparent film dressing), used for insertion site care of short-term central venous and arterial catheters (intravascular catheters) in adult critical care patients using a cost-consequence model populated with data from published sources. A decision analytical cost-consequence model was developed which assigned each patient with an indwelling intravascular catheter and a standard dressing, a baseline risk of associated dermatitis, local infection at the catheter insertion site and catheter-related bloodstream infections (CRBSI), estimated from published secondary sources. The risks of these events for patients with a Tegaderm CHG were estimated by applying the effectiveness parameters from the clinical review to the baseline risks. Costs were accrued through costs of intervention (i.e. Tegaderm CHG or standard intravenous dressing) and hospital treatment costs depended on whether the patients had local dermatitis, local infection or CRBSI. Total costs were estimated as mean values of 10,000 probabilistic sensitivity analysis (PSA) runs. Tegaderm CHG resulted in an average cost-saving of £77 per patient in an intensive care unit. Tegaderm CHG also has a 98.5% probability of being cost-saving compared to standard i.v. dressings. The analyses suggest that Tegaderm CHG is a cost-saving strategy to reduce CRBSI and the results were robust to sensitivity analyses.
Silver deposition and tissue staining associated with wound dressings containing silver.
Walker, Michael; Cochrane, Christine A; Bowler, Philip G; Parsons, David; Bradshaw, Peter
2006-01-01
Argyria is the general term used to denote a clinical condition in which excessive administration and deposition of silver causes a permanent irreversible gray-blue discoloration of the skin or mucous membranes. The amount of discoloration usually depends on the route of silver delivery (ie, oral or topical administration) along with the body's ability to absorb and excrete the administered silver compound. Argyria is accepted as a rare dermatosis but once silver particles are deposited, they remain immobile and may accumulate during the aging process. Topical application of silver salts (eg, silver nitrate solution) may lead to transient skin staining. To investigate their potential to cause skin staining, two silver-containing dressings (Hydrofiber and nanocrystalline) were applied to human skin samples taken from electively amputated lower limbs. The potential for skin discoloration was assayed using atomic absorption spectroscopy. When the dressings were hydrated with water, a significantly higher amount of silver was released from the nanocrystalline dressing compared to the Hydrofiber dressing (P <0.005), which resulted in approximately 30 times more silver deposition. In contrast, when saline was used as the hydration medium, the release rates were low for both dressings and not significantly different (silver deposition was minimal). Controlling the amount of silver released from silver-containing dressings should help reduce excessive deposition of silver into wound tissue and minimize skin staining.
Hämmerle, Gilbert; Strohal, Robert
2016-04-01
The aim of this study was to determine the efficacy, safety and cost-effectiveness of an octenidine-based wound gel in the treatment of chronic venous leg ulcers. For this purpose, 49 wounds were treated with either modern wound-phase-adapted dressings alone (treatment arm 1; n = 17), octenidine wound gel plus modern wound-phase-adapted dressings (treatment arm 2; n = 17) or octenidine wound gel alone (treatment arm 3; n = 15). During the study period of 42 days with dressing changes every 3-5 days, wound healing characteristics and treatment costs of different dressings were analysed. Wound size reduction was significantly better (P = 0·028) in both octenidine wound gel treatment arms compared to modern dressings alone with total reductions of 14·6%, 64·1% and 96·2% in treatment arms 1-3. Early wound healing was merely observed under octenidine wound gel treatment (n = 9), whereby lowest treatment costs were generated by octenidine wound gel alone (€20·34/dressing change). As a result, the octenidine wound gel is cost-effective and well suitable for the treatment of chronic venous leg ulcers, considering both safety and promotion of wound healing. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Anjum, Sadiya; Gupta, Amlan; Sharma, Deepika; Gautam, Deepti; Bhan, Surya; Sharma, Anupama; Kapil, Arti; Gupta, Bhuvanesh
2016-07-01
This study is aimed at the development of a composite material for wound dressing containing nanosilver nanohydrogels (nSnH) along with Aloe vera and curcumin that promote antimicrobial nature, wound healing and infection control. Nanosliver nanohydrogels were synthesized by nanoemulsion polymerization of methacrylic acid (MAA) followed by subsequent crosslinking and silver reduction under irradiation. Both the polymerization and irradiation time had significant influence on the nanoparticle shape, size and its formation. Polyvinyl alcohol/polyethylene oxide/carboxymethyl cellulose matrix was used as gel system to blend with nSnH, A. vera, curcumin and coat it on the hydrolysed PET fabric to develop antimicrobial dressings. The cumulative release of silver from the dressing was found to be ~42% of the total loading after 48h. The antimicrobial activity of the dressings was studied against both Staphylococcus aureus and Escherichia coli. In vivo wound healing studies were carried out over a period of 16d on full-thickness skin wounds created on Swiss albino mice. Fast healing was observed in Gel/nSnH/Aloe treated wounds with minimum scarring, as compared to other groups. The histological studies showed A. vera based dressings to be the most optimum one. These results suggest that nSnH along with A. vera based dressing material could be promising candidates for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
Spatial filtering, color constancy, and the color-changing dress.
Dixon, Erica L; Shapiro, Arthur G
2017-03-01
The color-changing dress is a 2015 Internet phenomenon in which the colors in a picture of a dress are reported as blue-black by some observers and white-gold by others. The standard explanation is that observers make different inferences about the lighting (is the dress in shadow or bright yellow light?); based on these inferences, observers make a best guess about the reflectance of the dress. The assumption underlying this explanation is that reflectance is the key to color constancy because reflectance alone remains invariant under changes in lighting conditions. Here, we demonstrate an alternative type of invariance across illumination conditions: An object that appears to vary in color under blue, white, or yellow illumination does not change color in the high spatial frequency region. A first approximation to color constancy can therefore be accomplished by a high-pass filter that retains enough low spatial frequency content so as to not to completely desaturate the object. We demonstrate the implications of this idea on the Rubik's cube illusion; on a shirt placed under white, yellow, and blue illuminants; and on spatially filtered images of the dress. We hypothesize that observer perceptions of the dress's color vary because of individual differences in how the visual system extracts high and low spatial frequency color content from the environment, and we demonstrate cross-group differences in average sensitivity to low spatial frequency patterns.
Gharibi, Reza; Yeganeh, Hamid; Rezapour-Lactoee, Alireza; Hassan, Zuhair M
2015-11-04
A series of novel polyurethane/siloxane-based wound dressing membranes was prepared through sol-gel reaction of methoxysilane end-functionalized urethane prepolymers composed of castor oil and ricinoleic methyl ester as well as methoxysilane functional aniline tetramer (AT) moieties. The samples were fully characterized and their physicochemical, mechanical, electrical, and biological properties were assayed. The biological activity of these dressings against fibroblast cells and couple of microbes was also studied. It was revealed that samples that displayed electroactivity by introduction of AT moieties showed a broad range of antimicrobial activity toward different microorganisms, promising antioxidant (radical scavenging) efficiency and significant activity for stimulation of fibroblast cell growth and proliferation. Meanwhile, these samples showed appropriate tensile strength and ability for maintaining a moist environment over a wound by controlled equilibrium water absorption and water vapor transmission rate. The selected electroactive dressing was subjected to an in vivo assay using a rat animal model and the wound healing process was monitored and compared with analogous dressing without AT moieties. The recorded results showed that the electroactive dressings induced an increase in the rate of wound contraction, promoted collagen deposition, and encouraged vascularization in the wounded area. On the basis of the results of in vitro and in vivo assays, the positive influence of designed dressings for accelerated healing of a wound model was confirmed.
Civil Behavior, Safe-School Planning, and Dress Codes
ERIC Educational Resources Information Center
Studak, Cathryn M.; Workman, Jane E.
2007-01-01
This research examined news reports in order to identify incidents that precipitated dress code revisions. News reports were examined within the framework of rules for civil behavior. Using key words "school dress codes" and "violence," LEXIS/NEXIS was used to access 104 articles from 44 U.S. newspapers from December 3, 2004 to December 2, 2005.…
Cross Dressing and Gender Dysphoria in People with Learning Disabilities: A Descriptive Study
ERIC Educational Resources Information Center
Parkes, Georgina; Hall, Ian; Wilson, Daniel
2009-01-01
We aimed to determine the characteristics of people with learning disability who cross-dress or who have gender dysphoria. Using a retrospective review of anonymised data from clinical records about people referred to a specialist service. All 13 participants cross-dressed and 12 were biological males. Only one person was in a core transsexual…
Rural School District Dress Code Implementation: Perceptions of Stakeholders after First Year
ERIC Educational Resources Information Center
Wright, Krystal M.
2012-01-01
Schools are continuously searching for solutions to solve truancy, academic, behavioral, safety, and climate issues. One of the latest trends in education is requiring students to adhere to dress codes as a solution to these issues. Dress codes can range from slightly restrictive clothing to the requiring of a uniform. Many school district…
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
Effect of Most-to-Least Prompting Procedure on Dressing Skill of Students with Autism
ERIC Educational Resources Information Center
Çetrez-Iscan, Galibiye; Nurçin, Elçin; Fazlioglu, Yesim
2016-01-01
Dressing skill is one of the necessary self-care skills that is taught to individuals with autism in order for them to be able to live independently. Typically, developing individuals can acquire dressing skill on their own; however, children with autism have difficulties in learning such skill without systematic teaching. Thus, teaching dressing…
Davies, Phil
2016-01-01
Despite the implementation of prevention strategies, pressure ulcers (PUs) continue to be a challenging health problem for patients (and their carers), clinicians and health-care providers. One area of growing interest is the use of prophylactic dressings (which were originally designed for the treatment of PUs and other wound types) as a component of standard prevention measures. Over the past few years, a large amount of scientific and clinical data relating to this subject has been published in peer-reviewed journals and presented at international meetings and conferences. A substantial proportion of these data relate to one group of dressings: multi-layer foam dressings with Safetac, which are manufactured by Mölnlycke Health Care (Gothenburg, Sweden). This evidence pool has influenced the experts involved in updating the Clinical Practice Guideline, produced by the National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance, on the prevention and treatment of PUs. The updated Guideline, published in 2014, recommends that, as part of their PU prevention regimens, clinicians should consider applying prophylactic dressings to bony prominences in anatomical areas that are frequently subjected to friction and shear. A literature review was undertaken to identify clinical data from the entire evidence hierarchy, as well as scientific data from laboratory studies, on the use of multi-layer foam dressings with Safetac in the prevention of pressure ulceration. The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier B, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (i.e. oral, e-posters and posters) of relevance to the review. Clinical and health economic experts have undertaken numerous studies, including randomised controlled trials, to assess the efficacy and cost-effectiveness of using multi-layer foam dressings with Safetac as a component of standard PU prevention strategies. The results of these studies indicate that the application of multi-layer foam dressings containing Safetac can reduce the occurrence of PUs on anatomical locations such as the sacrum and the heel, and underneath medical devices. Scientists have also developed and used laboratory methods to gain a better understanding of how prophylactic dressings work. The results of these studies indicate that the composition of foam dressings containing Safetac (i.e. their multi-layer structure) sets them apart from other dressings due to their ability to mediate the effects of physical forces (i.e. pressure, friction and shear) and control microclimate, all of which contribute to pressure ulceration. The evidence pool clearly indicates that the prophylactic use of multi-layer foam dressings with Safetac as a component of standard prevention measures is beneficial to the clinician, the health-care provider and the patient. It should be noted that the findings outlined in this review may not be transferable to other products as their makeup and components are likely to differ significantly from those of multi-layer foam dressings with Safetac. As the importance of evidence-based practice and the need for cost-effective care continues to grow, clinicians and provider should carefully consider this point when selecting prophylactic dressings for PU prevention.
Santamaria, N; Gerdtz, M; Liu, W; Rakis, S; Sage, S; Ng, A W; Tudor, H; McCann, J; Vassiliou, T; Morrow, F; Smith, K; Knott, J; Liew, D
2015-08-01
Critically ill patients are at high risk of developing pressure ulcers (PU), with the sacrum and heels being highly susceptible to pressure injuries. The objective of our study was to evaluate the clinical effectiveness of a new multi-layer, self-adhesive soft silicone foam heel dressing to prevent PU development in trauma and critically ill patients in the intensive care unit (ICU). A cohort of critically ill patients were enrolled at the Royal Melbourne Hospital. Each patient had the multi-layer soft silicone foam dressing applied to each heel on admission to the emergency department. The dressings were retained with a tubular bandage for the duration of the patients' stay in the ICU. The skin under the dressings was examined daily and the dressings were replaced every three days. The comparator for our cohort study was the control group from the recently completed Border Trial. Of the 191 patients in the initial cohort, excluding deaths, loss to follow-up and transfers to another ward, 150 patients were included in the final analysis. There was no difference in key demographic or physiological variables between the cohorts, apart from a longer ICU length of stay for our current cohort. No PUs developed in any of our intervention cohort patients compared with 14 patients in the control cohort (n=152; p<0.001) who developed a total of 19 heel PUs. We conclude, based on our results, that the multi-layer soft silicone foam dressing under investigation was clinically effective in reducing ICU-acquired heel PUs. The findings also support previous research on the clinical effectiveness of multi-layer soft silicone foam dressings for PU prevention in the ICU.
Fischer, Sebastian; Wall, Jennifer; Pomahac, Bohdan; Riviello, Robert; Halvorson, Eric G
2016-03-01
The use of negative-pressure-wound-therapy (NPWT) is associated with improved outcomes in smaller burns. We report our experience using extra-large (XL) NPWT dressings to treat ≥15% total body surface area (TBSA) burned and describe our technique and early outcomes. We also provide NPWT exudate volume for predictive fluid resuscitation in these critically ill patients. We retrospectively reviewed patients treated with XL-NPWT from 2012 to 2014. Following excision/grafting, graft and donor sites were sealed with a layered NPWT dressing. We documented wound size, dressing size, NPWT outputs, graft take, wound infections, and length of stay (LOS). Mean NPWT exudate volume per %TBSA per day was calculated. Twelve burn patients (mean TBSA burned 30%, range 15-60%) were treated with XL-NPWT (dressing TBSA burned and skin graft donor sites range 17-44%). Average graft take was 97%. No wound infections occurred. Two patients had burns ≥50% TBSA and their LOS was reduced compared to ABA averages. XL-NPWT outputs peaked at day 1 after grafting followed by a steady decline until dressings were removed. Average XL-NPWT dressing output during the first 5 days was 101±66mL/%BSA covered per day. 2 patients developed acute kidney injury. The use of XL-NPWT to treat extensive burns is feasible with attention to application technique. NPWT dressings appear to improve graft take, and to decrease risk of infection, LOS, and pain and anxiety associated with wound care. Measured fluid losses can improve patient care in future applications of NPWT to large burn wounds. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-11-01
To gain an understanding of Latino/Hispanic caregivers' dementia-related dressing issues, their impressions of using a "smart" context-aware dresser to coach dressing, and recommendations to improve its acceptability. The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer's disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-01-01
Objective To gain an understanding of Latino/Hispanic caregivers’ dementia-related dressing issues, their impressions of using a “smart” context-aware dresser to coach dressing, and recommendations to improve its acceptability. Method The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer’s disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Results Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Conclusion Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Walker, Michael; Bowler, Philip G; Cochrane, Christine A
2007-09-01
Excess or "uncontrolled" proteinase activity in the wound bed has been implicated as one factor that may delay or compromise wound healing. One proteinase group--matrix metalloproteinases--includes collagenases, elastase, and gelatinases and can be endogenous (cell) or exogenous (bacterial) in origin. A study was conducted to assess the ability of five silver-containing wound care products to reduce a known matrix metalloproteinase supernatant concentration in vitro. Four silver-containing wound dressings (a carboxy-methyl cellulose, a nanocrystalline, a hydro-alginate, and a collagen/oxidized regenerated cellulose composite dressing), along with a 0.5% aqueous silver nitrate [w/v] solution and controls for matrix metalloproteinase-2 and matrix metalloproteinase-9 sourced from ex vivo dermal tissue and blood monocytes, respectively, were used. Extracts were separated and purified using gelatine-Sepharose column chromatography and dialysis and polyacrylamide gel electrophoretic zymography was used to analyze specific matrix metalloproteinase activity. All dressings and the solution were shown to sequester both matrix metalloproteinases. The silver-containing carboxy-methyl cellulose dressing showed significantly greater sequestration for matrix metalloproteinase-2 at 6 and 24 hours (P< 0.001) compared to the other treatments. For matrix metalloproteinase-9, both the carboxy-methyl cellulose dressing and the oxidized regenerated cellulose dressing achieved significant sequestration when compared to the other treatments at 24 hours (P <0.001), which was maintained to 48 hours (P < 0.001). Results from this study show that silver-containing dressings are effective in sequestering matrix metalloproteinase-2 and -9 and that this can be achieved without a sacrificial protein (eg, collagen). Although the varying ability of wound dressings to sequester matrix metalloproteinases has been shown in vitro, further in vivo evidence is required to confirm these findings.
Management of Psychotropic Drug-Induced DRESS Syndrome: A Systematic Review.
Bommersbach, Tanner J; Lapid, Maria I; Leung, Jonathan G; Cunningham, Julie L; Rummans, Teresa A; Kung, Simon
2016-06-01
Drug rash with eosinophilia and systemic symptoms (DRESS) is a severe cutaneous eruption that has been linked to several common drugs and drug categories, including antiepileptics, allopurinol, sulfonamides, and various antibiotics; however, because of a number of recent case reports linking psychotropic medications to this condition, DRESS is increasingly recognized among psychiatrists. We systematically reviewed all psychotropic drugs linked to DRESS syndrome, and this article summarizes the clinical management relevant to psychiatric professionals. A comprehensive search was performed using Ovid MEDLINE, Ovid EMBASE, Ovid Cochrane Database of Systematic Reviews, Web of Science, Scopus, and Litt's Drug Eruption and Reaction Database for articles published in English during the past 20 years (1996-2015) using the search terms (1) psychotropic drugs OR serotonin uptake inhibitors AND DRESS or (2) psychotropic drugs AND drug reaction (or rash) eosinophilia systemic syndrome, and all article abstracts were screened for inclusion and exclusion criteria by 3 reviewers. Two independent reviewers examined the full text of 163 articles, of which 96 (25 original articles, 12 review articles, 55 case reports, and 4 letters to the editor) were included in the systematic review. We identified 1072 cases of psychotropic drug-induced DRESS, with carbamazepine, lamotrigine, phenytoin, valproate, and phenobarbital being the most implicated drugs. Based on our review of the literature, we outline management principles that include prompt withdrawal of the causative drug, hospitalization, corticosteroid therapy, and novel treatments, including intravenous immunoglobulin, cyclophosphamide, and cyclosporine, for corticosteroid-resistant DRESS. Finally, we outline strategies for treating comorbid psychiatric illness after a DRESS reaction to the psychotropic medication. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Karlsson, Bodil S A; Allwood, Carl Martin
2016-01-01
The Dress photograph, first displayed on the internet in 2015, revealed stunning individual differences in color perception. The aim of this study was to investigate if lay-persons believed that the question about The Dress colors was answerable. Past research has found that optimism is related to judgments of how answerable knowledge questions with controversial answers are (Karlsson et al., 2016). Furthermore, familiarity with a question can create a feeling of knowing the answer (Reder and Ritter, 1992). Building on these findings, 186 participants saw the photo of The Dress and were asked about the correct answer to the question about The Dress' colors (" blue and black," "white and gold," "other, namely…," or "there is no correct answer" ). Choice of the alternative "there is no correct answer" was interpreted as believing the question was not answerable. This answer was chosen more often by optimists and by people who reported they had not seen The Dress before. We also found that among participants who had seen The Dress photo before, 19%, perceived The Dress as "white and gold" but believed that the correct answer was "blue and black ." This, in analogy to previous findings about non-believed memories (Scoboria and Pascal, 2016), shows that people sometimes do not believe the colors they have perceived are correct. Our results suggest that individual differences related to optimism and previous experience may contribute to if the judgment of the individual perception of a photograph is enough to serve as a decision basis for valid conclusions about colors. Further research about color judgments under ambiguous circumstances could benefit from separating individual perceptual experience from beliefs about the correct answer to the color question. Including the option "there is no correct answer " may also be beneficial.
Hierarchy of Dysfunction Related to Dressing Performance in Stroke Patients: A Path Analysis Study.
Fujita, Takaaki; Nagayama, Hirofumi; Sato, Atsushi; Yamamoto, Yuichi; Yamane, Kazuhiro; Otsuki, Koji; Tsuchiya, Kenji; Tozato, Fusae
2016-01-01
Previous reports indicated that various dysfunctions caused by stroke affect the level of independence in dressing. These dysfunctions can be hierarchical, and these effects on dressing performance can be complicated in stroke patients. However, there are no published reports focusing on the hierarchical structure of the relationships between the activities of daily living and balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits. The purpose of this study was to elucidate the hierarchical and causal relationships between dressing performance and these dysfunctions in stroke patients. This retrospective study included 104 first-time stroke patients. The causal relationship between the dressing performance and age, time post stroke, balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits were examined using path analysis. A hypothetical path model was created based on previous studies, and the goodness of fit between the data and model were verified. A modified path model was created that achieved an almost perfect fit to the data. Balance function and abdominal muscle strength have direct effects on dressing performance, with standardized direct effect estimates of 0.78 and 0.15, respectively. Age, motor and sensory functions of the affected lower limb, and strength of abdominal muscle and knee extension on the unaffected side have indirect effects on dressing by influencing balance function. Our results suggest that dressing performance depends strongly on balance function, and it is mainly influenced by the motor function of the affected lower limb.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Background: Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. Materials and Methods: A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. Results: There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Conclusions: Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief. PMID:27186201
A dressed spin qubit in silicon
Laucht, Arne; Kalra, Rachpon; Simmons, Stephanie; ...
2016-10-17
Coherent dressing of a quantum two-level system provides access to a new quantum system with improved properties—a different and easily tunable level splitting, faster control and longer coherence times. In our work we investigate the properties of the dressed, donor-bound electron spin in silicon, and assess its potential as a quantum bit in scalable architectures. The two dressed spin-polariton levels constitute a quantum bit that can be coherently driven with an oscillating magnetic field, an oscillating electric field, frequency modulation of the driving field or a simple detuning pulse. We measure coherence times of T* 2p = 2.4 ms andmore » T Hahn 2p = 9 ms, one order of magnitude longer than those of the undressed spin. Moreover, the use of the dressed states enables coherent coupling of the solid-state spins to electric fields and mechanical oscillations.« less
Control of traumatic wound bleeding by compression with a compact elastic adhesive dressing.
Naimer, Sody Abby; Tanami, Menachem; Malichi, Avishai; Moryosef, David
2006-07-01
Compression dressing has been assumed effective, but never formally examined in the field. A prospective interventional trial examined efficacy and feasibility of an elastic adhesive dressing compression device in the arena of the traumatic incident. The primary variable examined was the bleeding rate from wounds compared before and after dressing. Sixty-two consecutive bleeding wounds resulting from penetrating trauma were treated. Bleeding intensity was profuse in 58%, moderate 23%, and mild in 19%. Full control of bleeding was achieved in 87%, a significantly diminished rate in 11%, and, in 1 case, the technique had no influence on the bleeding rate. The Wilcoxon test for variables comparing bleeding rates before and after the procedure obtained significant difference (Z = -6.9, p < 0.01). No significant complications were observed. Caregivers were highly satisfied in 90% of cases. Elastic adhesive dressing was observed as an effective and reliable technique, demonstrating a high rate of success without complications.
Dressings as an adjunct to pressure ulcer prevention: consensus panel recommendations.
Black, Joyce; Clark, Michael; Dealey, Carol; Brindle, Christopher T; Alves, Paulo; Santamaria, Nick; Call, Evan
2015-08-01
The formulation of recommendations on the use of wound dressings in pressure ulcer prevention was undertaken by a group of experts in pressure ulcer prevention and treatment from Australia, Portugal, UK and USA. After review of literature, they concluded that there is adequate evidence to recommend the use of five-layer silicone bordered dressings (Mepilex Border Sacrum(®) and 3 layer Mepilex Heel(®) dressings by Mölnlycke Health Care, Gothenburg, Sweden) for pressure ulcer prevention in the sacrum, buttocks and heels in high-risk patients, those in Emergency Department (ED), intensive care unit (ICU) and operating room (OR). Literature on which this recommendation is based includes one prospective randomised control trial, three cohort studies and two case series. Recommendations for dressing use in patients at high risk for pressure injury and shear injury were also provided. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wiegand, C; Abel, M; Ruth, P; Hipler, U C
2011-11-01
A comprehensive in vitro approach was used to assess the effects of superabsorbent polymer (SAP) containing wound dressings in treatment of non-healing wounds. A slight negative effect on HaCaT cells was noted in vitro which is most likely due to the Ca(2+) deprivation of the medium by binding to the SAP. It could be shown that SAP wound dressings are able to bind considerable amounts of elastase reducing enzyme activity significantly. Furthermore, SAP's inhibit the formation of free radicals. The SAP-containing wound dressings tested also exhibited a significant to strong antimicrobial activity effectively impeding the growth of gram-negative and gram-positive bacteria as well as yeasts. In conclusion, in vitro data confirm the positive effect of SAP wound dressings observed in vivo and suggest that they should be specifically useful for wound cleansing.
Dress Fashion in Feminist and Child Rights Campaigns in Ghanaian Public Sculptures of the 1990s
ERIC Educational Resources Information Center
Essel, Osuanyi Quaicoo; Opoku-Mensah, Isaac
2017-01-01
This article examines how dress fashion in outdoor sculptures of the 1990s in the Accra cityscape accentuated feminist activism, sensitised child right campaigns, and encouraged girl-child education in support of governmental efforts and activism of civil society organisations in Ghana. It gives attention to how dress fashion of the time was used…
USDA-ARS?s Scientific Manuscript database
An intelligent dressing is a self-adjusting material with multifunctional properties and/or a biosensor-interface designed to treat specific pathological issues of wounds at a molecular or cellular level. The ability to detect and treat excessive protease levels in wounds, one indicator of chronic w...
ERIC Educational Resources Information Center
Sebastian, Richard J.; Bristow, Dennis
2008-01-01
In this article, the authors examine the effects of style of dress, forms of address, and gender of the stimulus person on business students' perceptions of professors' attributes. Student participants (125 women, 132 men) rated the stimulus person on indexes of attractiveness, trustworthiness, credibility, and likeability. Style of dress and form…
Politicas de uniformes y codigos de vestuario (Uniforms and Dress-Code Policies). ERIC Digest.
ERIC Educational Resources Information Center
Lumsden, Linda
This digest in Spanish examines schools' dress-code policies and discusses the legal considerations and research findings about the effects of such changes. Most revisions to dress codes involve the use of uniforms, typically as a way to curb school violence and create a positive learning environment. A recent survey of secondary school principals…
Dressing control of biphoton waveform transitions
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Zhang, Da; Hao, Ling; Chen, Haixia; Wang, Zhiguo; Zhang, Yanpeng
2018-05-01
We experimentally realize and theoretically analyze narrow-band biphotons generated in a hot rubidium vapor cell by four-wave-mixing processing. A dressing laser beam is used to alternate both linear and nonlinear susceptibilities of the vapor, thereby modifying the biphoton's temporal correlation function. Most notably, the correlation time is increased from 6 to 165 ns. The biphoton shape is also shown to change as a result of the coupled-states dressing. We observed Rabi oscillations and optical precursors in hot atomic vapor cells. We also theoretically simulated biphoton correlation times as influenced by dressing-laser detuning and power, the results of which are consistent with our experiments.
Evidence review: the clinical benefits of Safetac technology in wound care.
Davies, Phil; Rippon, Mark
2008-11-01
Common causes of trauma and wound pain include: the removal of dressings that become stuck to the wound bed; skin stripping of peri-wound skin, as a result of the repeated application and removal of adhesive dressings; and tissue excoriation and maceration of the peri-wound skin, due to inadequate management of wound exudate. This supplement outlines how dressings with Safetac adhesive technology can help clinicians to avoid these problems. A review of the clinical and scientific evidence relating to dressings with Safetac clearly demonstrates that they can be used to prevent trauma and minimise pain on a wide range of wound types and skin injuries.
The Concept of Fashion Design on the Basis of Color Coordination Using White LED Lighting
NASA Astrophysics Data System (ADS)
Mizutani, Yumiko; Taguchi, Tsunemasa
This thesis focuses on the development of fashion design, especially a dress coordinated with White LED Lighting (=LED). As for the design concept a fusion of the advanced science and local culture was aimed for. For such a reason this development is a very experimental one. Here in particular I handled an Imperial Court dinner dress for the last Japanese First Lady, Mrs. Akie Abe who wore it at the Imperial Court dinner for the Indonesian First Couple held on November 2006 to. This dress made by Prof. T. Taguchi and I open up a new field in the dress design.
Dutra, R A A; Salomé, G M; Leal, L M F; Alves, M G; Moura, J P; Silva, A T; Pereira, V O S; de Brito, M J A; Ferreira, L M
2016-11-02
To evaluate and compare the costs of using a transparent polyurethane film (PF) and hydrocolloid dressing (HD) in the prevention of pressure ulcers (PUs). This descriptive, observational, longitudinal, comparative study was conducted in the intensive care units, coronary care unit and medical clinic of a charity hospital in Brazil. Data were collected during a 30-day study period, consisting of physical examination, assessment of risk factors for PU development and application of the Braden scale, which were performed at inclusion in the study and once daily during hospitalisation. Either PF or HD was applied bilaterally in the sacral and trochanteric regions for prevention of PUs in patients at a moderate to high risk of PUs according to the Braden scale, and costs of using PU preventive dressings were estimated. The mean total costs per dressing change per patient when using the HD and PF to prevent PUs were 413.60 BRL and 74.04 BRL, respectively. There were significant between-group differences in mean costs for all variables, except for saline solution and nurse-technician services. Results showed that the mean cost per dressing change per patient was lower when using the transparent PF than when using the HD.
The Dress: Transforming a web viral event into a scientific survey.
Moccia, Marcello; Lavorgna, Luigi; Lanzillo, Roberta; Brescia Morra, Vincenzo; Tedeschi, Gioacchino; Bonavita, Simona
2016-05-01
The Dress picture recently has become a hot topic on the Internet, prompting a debate whether it was black and blue, or white and gold. To investigate The Dress color perception in both multiple sclerosis (MS) patients, characterized by frequent visual system impairment with ensuing color vision effects, and general population. We developed a questionnaire to record demographics, clinical features, and The Dress color perception, posted on general and MS-specific social networks. No statistically significant differences were observed in The Dress color perception between MS patients (n=103) and general population (n=441). Furthermore, white and gold color perception was positively associated with aging in the general population (p=0.04), whereas negatively associated with progressive course (p=0.03) and longer disease duration (p<0.001) in MS patients, independently from patients' age. The Dress black and blue or white and gold perception might be due to aging in the general population, whereas black and blue perception, despite of aging, might suggest a specific effect of the MS burden (i.e. disease duration and progression) on the visual structures specifically involved in the white and gold perception. Copyright © 2016 Elsevier B.V. All rights reserved.
Endo, Arisa; Suzuki, Makoto; Akagi, Atsumi; Chiba, Naoyuki; Ishizaka, Ikuyo; Matsunaga, Atsuhiko; Fukuda, Michinari
2015-03-01
The purpose of this study was to examine the reliability and validity of the Upper-body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the learning process of new component actions of upper-body dressing in patients diagnosed with dementia and hemiparesis. This was a preliminary correlational study of concurrent validity and reliability in which 10 vascular dementia patients with hemiparesis were enrolled and assessed repeatedly by six occupational therapists by means of the UBDS and the dressing item of the Functional Independence Measure (FIM). Intraclass correlation coefficient was 0.97 for intra-rater reliability and 0.99 for inter-rater reliability. The level of correlation between UBDS score and FIM dressing item scores was -0.93. UBDS scores for paralytic hand passed into the sleeve and sleeve pulled up beyond the shoulder joint were worse than the scores for the other components of the task. The UBDS has good reliability and validity for vascular dementia patients with hemiparesis. Further research is needed to investigate the relation between UBDS score and the effect of intervention and to clarify sensitivity or responsiveness of the scale to clinical change. Copyright © 2014 John Wiley & Sons, Ltd.
Mori, Michela; Rossi, Silvia; Ferrari, Franca; Bonferoni, Maria C; Sandri, Giuseppina; Riva, Federica; Tenci, Marika; Del Fante, Claudia; Nicoletti, Giovanni; Caramella, Carla
2016-03-01
Platelet lysate (PL) was loaded into dressings based on chitosan glutamate (CSG) low and high molecular weight, sericin (Ser), and glycine (Gly). A synergic effect of Ser and PL on fibroblast proliferation was proved in vitro. Two different PL loading approaches were considered: the first provided to prepare dressings by freeze-drying a mixture of PL and CSG/Gly/Ser solution, the second approach consisted in the extemporarily loading of PL in the CSG/Gly/Ser freeze-dried dressings. As for the first approach, PL loading did not produce any variation in dressing mechanical properties. Such dressings absorbed a high amount (about 8-fold of dry weight) of phosphate-buffered saline (fluid mimicking wound exudate), forming a gel with pseudoplastic and elastic properties. Platelet-derived growth factor AB assay indicated that neither freeze-drying nor the excipients alter PL growth factor content. As for the second approach, mechanical and rheological properties of the gel formed upon PL absorption enabled to choose a PL loading of about 90 μL/cm(2). Upon contact with fibroblasts, all PL loaded formulations increased the number not only of viable cells but also of those in the proliferative phase. Histological studies effected on human skin strips pointed out the positive effect of PL loaded dressings on dermal matrix reconstruction. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Ferreira, Lydia M; Blanes, Leila; Gragnani, Alfredo; Veiga, Daniela F; Veiga, Frederico; Nery, Gilka B; Rocha, Gustavo H; Gomes, Heitor C; Rocha, Mario G; Okamoto, Regina
2009-06-01
Objective. The aim of this study was to compare the health-related quality of life (HRQoL) and self-esteem of patients who underwent split-thickness skin grafting, when either cellulose dressings or rayon dressings were applied to the donor sites. A total of 25 patients, who were enrolled at five participant hospitals and required split-thickness skin grafting for various clinical reasons, were randomized into two treatment groups, the rayon dressing group (n = 13), or the cellulose dressing group (n = 12). All patients were assessed preoperatively and 60 days postoperatively. The HRQoL was assessed with the Short Form-36 (SF-36) health survey questionnaire, and self-esteem was evaluated using the Rosenberg Self-Esteem Scale (RSE)/UNIFESP-EPM (Brazilian versions). There were no surgery-related complications during the study period. In both treatment groups, SF-36 scores for emotional role, mental health, vitality, and general health decreased from baseline. RSE scores increased from baseline in both treatment groups, showing a reduction in self-esteem after treatment. There was a statistical difference (P = 0.024) in the SF-36 bodily pain domain for the rayon group. There were no significant differences in HRQoL and self-esteem between treatment groups. In the rayon-dressing group, there was a significant decrease in bodily pain from baseline .
A review of negative-pressure wound therapy in the management of burn wounds.
Kantak, Neelesh A; Mistry, Riyam; Halvorson, Eric G
2016-12-01
Negative pressure has been employed in various aspects of burn care and the aim of this study was to evaluate the evidence for each of those uses. The PubMed and Cochrane CENTRAL databases were queried for articles in the following areas: negative pressure as a dressing for acute burns, intermediate treatment prior to skin grafting, bolster for skin autografts, dressing for integration of dermal substitutes, dressing for skin graft donor sites, and integrated dressing in large burns. Fifteen studies met our inclusion criteria. One study showed negative pressure wound therapy improved perfusion in acute partial-thickness burns, 8 out of 9 studies showed benefits when used as a skin graft bolster dressing, 1 out of 2 studies showed improved rate of revascularization when used over dermal substitutes, and 1 study showed increased rate of re-epithelialization when used over skin graft donor sites. Negative pressure can improve autograft take when used as a bolster dressing. There is limited data to suggest that it may also improve the rate of revascularization of dermal substitutes and promote re-epithelialization of skin graft donor sites. Other uses suggested by studies that did not meet our inclusion criteria include improving vascularity in acute partial-thickness burns and as an integrated dressing for the management of large burns. Further studies are warranted for most clinical applications to establish negative pressure as an effective adjunct in burn wound care. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Tran, Phat L; Hamood, Abdul N; de Souza, Anselm; Schultz, Gregory; Liesenfeld, Bernd; Mehta, Dilip; Reid, Ted W
2015-01-01
Bacterial infection of acute and chronic wounds impedes wound healing significantly. Part of this impediment is the ability of bacterial pathogens to grow in wound dressings. In this study, we examined the effectiveness of a polyurethane (PU) foam wound dressings coated with poly diallyl-dimethylammonium chloride (pDADMAC-PU) to inhibit the growth and biofilm development by three main wound pathogens, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii, within the wound dressing. pDADMAC-PU inhibited the growth of all three pathogens. Time-kill curves were conducted both with and without serum to determine the killing kinetic of pDADMAC-PU. pDADMAC-PU killed S. aureus, A. baumannii, and P. aeruginosa. The effect of pDADMAC-PU on biofilm development was analyzed quantitatively and qualitatively. Quantitative analysis, colony-forming unit assay, revealed that pDADMAC-PU dressing produced more than eight log reduction in biofilm formation by each pathogen. Visualization of the biofilms by either confocal laser scanning microscopy or scanning electron microscopy confirmed these findings. In addition, it was found that the pDADMAC-PU-treated foam totally inhibited migration of bacteria through the foam for all three bacterial strains. These results suggest that pDADMAC-PU is an effective wound dressing that inhibits the growth of wound pathogens both within the wound and in the wound dressing. © 2014 by the Wound Healing Society.
9. Photographic copy of blueprint dated 1931; H.P. Henschien, Chicago, ...
9. Photographic copy of blueprint dated 1931; H.P. Henschien, Chicago, architect; Original in collection of Rath drawings and blueprints owned by Waterloo Community Development Board, Waterloom, Iowa; PLAN OF HOG DRESSING FLOOR ON 4TH LEVEL OF BUILDING 92; SHOWS LAYOUT OF DRESSING EQUIPMENT - Rath Packing Company, Hog Dressing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
Vas, Jorge; Modesto, Manuela; Mendez, Camila; Perea-Milla, Emilio; Aguilar, Inmaculada; Carrasco-Lozano, Jesus Manuel; Faus, Vicente; Martos, Francisco
2008-01-01
Background Venous leg ulcers constitute a chronic recurring complaint that affects 1.0–1.3% of the adult population at some time in life, and which corresponds to approximately 75% of all chronic ulcers of the leg. Multilayer compression bandaging is, at present, the only treatment that has been proved to be effective in treating this type of ulcer. There is no consensus, however, about the dressings that may be applied, beneath the compression, to promote the healing of this type of ulcer, as there does not seem to be any added benefit from using special dressings rather than simple, low-adherence ones. As well as analgesia, acupuncture provokes peripheral vasodilation, in skin and muscles – which has been demonstrated both experimentally and in clinical practice – probably due to the axon reflex, among other mechanisms. The aim of the present study is to measure the effectiveness and cost of compression treatment for venous leg ulcers combined with special dressings, in comparison with low-adherence ones and acupuncture. Methods/design Cluster-randomized open-labeled trial, at 15 primary healthcare clinics in the Sevilla-Sur Healthcare District, with a control group treated with compression bandaging and low-adherence dressings; the experiment will consist, on the one hand, of the compression treatment applied in combination with special dressings (Treatment 1), and on the other, the compression treatment applied in association with low-adherence dressings, together with acupuncture (Treatment 2). Discussion The results will be measured and recorded in terms of the median time elapsed until complete healing of the ulcer, and the rate of complete healing at 3 months after beginning the treatment. An economic analysis will also be made. This study, carried out in the context of real clinical practice, will provide information for decision-taking concerning the effectiveness of special dressings. Moreover, for the first time a high-quality study will evaluate the effectiveness of acupuncture in the process of healing venous leg ulcers. Trial registration Current Controlled Trials ISRCTN26438275. PMID:18547419
Coufal, C D; Chavez, C; Niemeyer, P R; Carey, J B
2006-03-01
Top-dressing is a method of broiler litter management in which a thin layer of new, clean litter material is spread over the top of previously used litter prior to placement of a new flock. This fresh layer of bedding material increases the absorptive capacity of the litter and decreases litter caking. Although this practice has been widely used in the poultry industry for many years, no research has been conducted to quantify the effects the practice has on broiler performance, litter production rates, and nutrient content, or the ability of broiler litter to retain manure N and prevent volatilization. An experiment was conducted to quantify these parameters under simulated commercial conditions in a research facility. Nine consecutive flocks of broilers were reared on recycled broiler litter that had previously been used for 9 flocks. Control pens received no litter treatment whereas top-dressed pens received a thin layer of new rice hulls (1 to 2 cm) before the placement of each flock. Nitrogen loss was calculated using the mass balance method. Average broiler performance was not different between the top-dressed and control pens. Top-dressing of litter significantly (P < 0.05) reduced caked litter production compared with control pens in 6 of 9 flocks. However, average total litter production over all 9 flocks was not different between the 2 litter management strategies. In all flocks, litter N content was significantly reduced in top-dressed pens compared with control pens. As a result, litter C:N ratios were significantly higher for pens with top-dressed litter. Differences in N loss between the treatments were not consistent. Average N loss for all flocks was 10.61 and 11.92 g of N/kg of marketed broiler for control and top-dressed pens, respectively, or 20.1 and 22.5% of N inputs, respectively. Based on this experiment, top-dressing of recycled broiler litter would not be recommended as a strategy to reduce the volatilization of N from broiler rearing facilities and, in fact, may actually increase N loss.
Song, David H; Wu, Liza C; Lohman, Robert F; Gottlieb, Lawrence J; Franczyk, Mieczyslawa
2003-01-01
A method to refine the treatment of sternal wounds using Vacuum Assisted Closure (V.A.C.) therapy as the bridge between débridement and delayed definitive closure is described. A retrospective review of 35 consecutive patients with sternal wound complications over a 2-year period (March of 1999 to March of 2001) was performed. The treatment of sternal wounds with traditional twice-a-day dressing changes was compared with the treatment with the wound V.A.C. device. An analysis of the number of days between initial débridement and closure, number of dressing changes, number and types of flaps needed for reconstruction, and complications was performed. Eighteen patients were treated with traditional twice-a-day dressing changes and 17 patients were treated with V.A.C. therapy alone. The two groups were similar regarding age, sex, type of cardiac procedure, and type of sternal wound. The V.A.C. therapy group had a trend toward a shorter interval between débridement and closure, with a mean of 6.2 days, whereas the dressing change group had mean of 8.5 days. The V.A.C. therapy group had a significantly lower number of dressing changes, with a mean of three, whereas the twice-a-day dressing change group had a mean of 17 (p < 0.05). Reconstruction required an average of 1.5 soft-tissue flaps per patient treated with traditional dressing changes versus 0.9 soft-tissue flaps per patient for those treated with V.A.C. therapy (p < 0.05). Before closure, there was one death among patients undergoing dressing changes and three in the V.A.C. therapy group, all of which were unrelated to the management of the sternal wound. Patients with sternal wounds who have benefited from V.A.C. therapy alone have a significant decrease in the number of dressing changes and number of soft-tissue flaps needed for closure. Finally, the V.A.C. therapy group had a trend toward a decreased number of days between débridement and closure.
Souliotis, Kyriakos; Kalemikerakis, Ioannis; Saridi, Maria; Papageorgiou, Manto; Kalokerinou, Athena
2016-05-01
The aim of the study was a cost and clinical effectiveness analysis between moist wound healing dressings and gauze in a homecare set up for the treatment of stage III and IV pressure ulcers up to complete healing. In addition, we assessed the overall economic burden on the Healthcare System. Treatment method for each patient was chosen randomly by using sealed opaque envelopes. The authors monitored the healing progress and recorded treatment costs without interfering with the treatment process. The healing progress was estimated by using surface measurement transparent films. To estimate treatment costs, the authors took into account labor costs, cost of dressings, as well the cost of other materials such as cleansing gauzes, normal saline, syringes, examination gloves, antiseptics and adhesive tape. The patient group under treatment with moist wound healing dressings consisted of 27 men and 20 women aged 75.1 ± 8,6 and had an average ulcer surface of 43.5 ± 30.70 cm(2) ; the patient group under treatment with gauze comprised 25 men and 23 women aged 77.02 ± 8.02 and had an average ulcer surface 41.52 ± 29.41 cm(2) (p = 0.25, 95% CI, Student's t test). The average healing time for the moist wound healing dressings group' was 85.56 ± 52.09 days, while 121.4 ± 52.21 days for the "gauze group" (p = 0.0001, 95% CI, Student's t test). The dressing change frequency per patient was reduced in the "moist wound healing dressings group," 49.5 ± 29.61, compared with a dressing change frequency per patient of 222.6 ± 101.86 for the "gauze group" (p = 0.0001, 95% CI, Student's t test). The use of moist wound healing dressings had a lower total treatment cost of 1,351 € per patient compared with, the use of gauzes (3,888 €). © 2016 by the Wound Healing Society.
Ozisik, Lale; Tanriover, Mine Durusu; Saka, Esen
2016-01-01
Drug rash with eosinophilia and systemic symptoms (DRESS) is a severe drug hypersensitivity reaction characterized by rash, fever and multi-organ failure. Limbic encephalitis (LE) is a rare disorder characterized by cognitive dysfunction with memory disturbance, seizures and psychiatric symptoms. We herein present an unusual case of DRESS syndrome due to lamotrigine with reactivation of Epstein-Barr virus, which developed autoimmune LE and syndrome of inappropriate antidiuretic hormone secretion. Discontinuation of lamotrigine, administration of methylprednisolone and intravenous immunoglobulin led to improvement. The LE in this case might have been caused by an autoimmune inflammatory mechanism associated with DRESS syndrome.
Honey-based dressings and wound care: an option for care in the United States.
Pieper, Barbara
2009-01-01
Honey-based wound dressings have been used worldwide since ancient times. A honey product received US Federal Drug Administration approval in 2007, making this dressing an option for wound care. Honey has been found to exert anti-inflammatory and antibacterial effects without antibiotic resistance, promote moist wound healing, and facilitate debridement. However, it may cause a stinging pain. As is true of any wound dressing, its use must be carefully selected and monitored. Continued research is needed to add to its evidence base. This article provides a summary of the current evidence base for the use of honey and a review of its therapeutic effects and discusses implications for WOC nursing practice.
Honey as a dressing for chronic wounds in adults.
Fox, Carolyn
2002-10-01
The aim of this review was to identify whether in adults with chronic wounds the use of honey as a wound dressing improves wound management outcomes. As no randomized controlled trials or comparative studies comparing the use of honey as a chronic wound dressing with usual treatment could be found, the review is based on case studies and serial case studies. These were reviewed using a framework broadly based on wound care case study guidelines (Nelson, 2000) and cohort study guidelines (Greenhalgh and Donald, 2000). Based on the case studies reviewed, honey appears to be a useful dressing in adults with chronic wounds, but the available evidence is weak and therefore must be interpreted with caution.
Choi, Jong Seo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jong Oh; Yong, Chul Soon; Cho, Kwan Hyung; Youn, Yu Seok; Jin, Sung Giu; Choi, Han-Gon
2016-10-01
To develop a novel neomycin sulfate-loaded hydrogel dressing (HD), numerous neomycin sulfate-loaded HDs were prepared with various amounts of polyvinyl alcohol (PVA), polyvinyl pyrrolidone (PVP) and sodium alginate (SA) using freeze-thawing technique, and their physical dressing properties, drug release, in vivo wound curing and histopathology in diabetic-induced rats were assessed. SA had a positive effect on a swelling capacity, but a negative effect on the physical dressing properties and drug release of HD. However, PVP did the opposite. In particular, the neomycin sulfate-loaded HD composed of drug, PVA, PVP and SA at the weight ratio of 1/10/0.8/0.8 had excellent swelling and bioadhesive capacity, good elasticity and fast drug release. Moreover, this HD gave more improved wound curing effect compared to the commercial product, ensured the disappearance of granulation tissue and recovered the wound tissue to normal. Therefore, this novel neomycin sulfate-loaded HD could be an effective pharmaceutical product for the treatment of wounds.
Chia, E K; Jih, C S
1994-09-01
We examined the effects of stereotyping on impression formation when encountering people dressed to represent a religious faith. We used stimulus photographs of eight male and female models dressed casually and a second photograph of one male and one female model in religious attire that was placed beside the control photos of models dressed causally. From each set of photographs, subjects selected a photo of the person with whom they would associate the various positive personality traits suggested by our stimulus questions. Subjects were students from a U.S. Catholic school, a U.S. public school, and a Malaysian Muslim school. All the subjects attributed more of the positive traits to photos of the models who were religiously attired than to photos of those who were casually dressed, but subjects from U.S. schools attributed more of the positive traits to the photos of religiously dressed models than did the subjects from the Malaysian school.
Kohl, K S; Farley, T A
2000-12-01
An outbreak of salmonellosis occurred among 63 wedding participants. The outbreak was investigated through cohort, laboratory, and environmental studies. Consumption of rice-dressing made from a commercially cooked, meat-based, rice-dressing mix was strongly associated with illness. Nineteen patient isolates, six company/grocery store isolates cultured from the rice-dressing mix, and one environmental isolate from a pump in the production line were of an identical outbreak strain of Salmonella Infantis characterized by pulsed-field gel electrophoresis. In the production line, cooked rice-dressing mix tested negative for S. Infantis before and positive after contact with the contaminated pump. The dressing-mix had an estimated 200 colony-forming units of salmonella per gram of product, and > 180,000 pounds were distributed in 9 states for > or = 2 months before contamination was recognized. Food manufacturers should be required to use systematic, hazard analysis critical control point risk management practices for all processed meat products, validated by periodic microbiologic monitoring of the end product.
Hwang, Deng-Fwu; Hsieh, Yu-Wen; Shiu, Yu-Cheng; Chen, Shu-Kong; Cheng, Chao-An
2002-02-01
There were five victims of neurotoxic food poisoning from a dried dressed fish fillet in Changhua County, Taiwan, in February 2000. The toxicity of the dried dressed fish fillets was 243 mouse units per g according to a tetrodotoxin bioassay. The partially purified toxin was identified as tetrodotoxin and anhydrotetrodotoxin. The sequence of the 376-nucleotide region in the cytochrome b gene of the mitochondrial DNA exhibited the same genotype as that of the toxic puffer fish Lagocephalus lunaris. The same single restriction site for Hinfl was found in the polymerase chain reaction (PCR) products from the dried dressed fish fillet and the muscle of L. lunaris, yielding two DNA fragments of 170 and 206 bp. However, no restriction site for Hinfl was found in the PCR products from other toxic puffer fishes, including Takifugu niphobles, Takifugu oblongus, and Takifugu rubripes. Therefore, the species of the dried dressed fish fillet was identified as L. lunaris and its causative agent was identified as tetrodotoxin.
Diluted povidone-iodine versus saline for dressing metal-skin interfaces in external fixation.
Chan, C K; Saw, A; Kwan, M K; Karina, R
2009-04-01
To compare infection rates associated with 2 dressing solutions for metal-skin interfaces. 60 patients who underwent distraction osteogenesis with external fixators were equally randomised into 2 dressing solution groups (diluted povidone-iodine vs. saline). Fixations were attained using either rigid stainless steel 5-mm diameter half pins or smooth stainless steel 1.8-mm diameter wires. Half-pin fixation had one metal-skin interface, whereas wire fixation had 2 interfaces. Patients were followed up every 2 weeks for 6 months. Of all 788 metal-skin interfaces, 143 (18%) were infected: 72 (19%) of 371 in the diluted povidone-iodine group and 71 (17%) of 417 in the saline group. Dressing solution and patient age did not significantly affect infection rates. Half-pin fixation was more likely to become infected than wire fixation (25% vs 15%). Saline is as effective as diluted povidone-iodine as a dressing solution for metal-skin interfaces of external fixators. Saline is recommended in view of its easy availability and lower costs.
Richards, Alastair J; Hagelstein, Sue M; Patel, Girish K; Ivins, Nicola M; Sweetland, Helen M; Harding, Keith G
2011-12-01
Combining silver-based dressings with negative pressure therapy after radical excision of chronically infected breast disease is a novel application of two technologies. One patient with complex, chronic, infected breast disease underwent radical excision of the affected area and was treated early with a combination of silver-based dressings and topical negative pressure therapy. The wound was then assessed sequentially using clinical measurements of wound area and depth, pain severity scores and level of exudation. It is possible to combine accepted techniques with modern dressing technologies that result in a positive outcome. In this case, the combination of a silver-based dressing with negative pressure therapy following radical excision proved safe and was well tolerated by the patient. Full epithelisation of the wound was achieved and there was no recurrence of the infection for the duration of the treatment. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.
Electron-hydrogen collisions in a laser field. (Reannouncement with new availability information)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, P.H.; Flannery, M.R.
1991-12-31
The Floquet treatment has already been successfully employed (Chu, Potvliege and Shakeshaft) in calculations of laser-induced multiphoton ionizations, where it provides dressed states for an atom in a laser field. The (perturbative) dressing of target states can have important consequences in laser-assisted scattering was illustrated by Byron and Joachain. These dressed states are useful, not only for laser-induced phenomena, but also as a collisional basis set for laser-assisted collisions. In this role they are in fact very appealing, since the Floquet treatment naturally lends itself to a time-independent analysis, and hence are compatible with present field-free scattering theories. Despite themore » apparent applicability of this approach, work along these lines has only just recently appeared (Sharma and Mohan, Smith and Flannery, Burke et al). Byron and Joachain have illustrated that perturbative dressing of the target states can have important consequences in laser-assisted scattering. Floquet dressing however provides a more complete description (Smith and Flannery).« less
Wettstein, Felix E; Kasteel, Roy; Garcia Delgado, Maria F; Hanke, Irene; Huntscha, Sebastian; Balmer, Marianne E; Poiger, Thomas; Bucheli, Thomas D
2016-08-24
Pesticide transport from seed dressings toward subsurface tile drains is still poorly understood. We monitored the neonicotinoid insecticides imidacloprid and thiamethoxam from sugar beet seed dressings in flow-proportional drainage water samples, together with spray applications of bromide and the herbicide S-metolachlor in spring and the fungicides epoxiconazole and kresoxim-methyl in summer. Event-driven, high first concentration maxima up to 2830 and 1290 ng/L for thiamethoxam and imidacloprid, respectively, were followed by an extended period of tailing and suggested preferential flow. Nevertheless, mass recoveries declined in agreement with the degradation and sorption properties collated in the groundwater ubiquity score, following the order bromide (4.9%), thiamethoxam (1.2%), imidacloprid (0.48%), kresoxim-methyl acid (0.17%), S-metolachlor (0.032%), epoxiconazole (0.013%), and kresoxim-methyl (0.003%), and indicated increased leaching from seed dressings compared to spray applications. Measured concentrations and mass recoveries indicate that subsurface tile drains contribute to surface water contamination with neonicotinoids from seed dressings.
Valley-selective photon-dressed states in transition metal dichalcogenides
NASA Astrophysics Data System (ADS)
LaMountain, Trevor; Chen, Yen-Jung; Stanev, Teodor K.; Stern, Nathaniel P.
2018-02-01
When electronic excitations in a semiconductor interact with light, the relevant quasiparticles are hybrid lightmatter dressed states, or exciton-polaritons. In monolayer transition metal dichalcogenides, a class of 2D direct bandgap semiconductors, optical excitations selectively populate distinct momentum valleys with correlated spin projection. The combination of this spin-valley locking with photon dressed states can lead to new optical phenomena in these materials. We present spectroscopic measurements of valley-specific exciton-polaritons in monolayer 2D materials in distinct regimes. When a monolayer is embedded in a dielectric microcavity, strong coupling exciton-polaritons are achieved. Cavity-modified dynamics of the dressed states are inferred from emission. Polarization persists up to room temperature in monolayer MoS2, in contrast with bare material. We also show that distinct regimes of valley-polarized exciton-polaritons can be accessed with microcavity engineering by tuning system parameters such as cavity decay rate and exciton-photon coupling strength. Further, we report results showing that polarization-sensitive ultrafast spectroscopy can enable sensitive measurements of the valley optical Stark shift, a light-induced dressed state energy shift, in monolayer semiconductors such as WSe2 and MoS2. These findings demonstrate distinct approaches to manipulating the picosecond dynamics of valleysensitive dressed states in monolayer semiconductors.
Systematic review of the use of prophylactic dressings in the prevention of pressure ulcers.
Clark, Michael; Black, Joyce; Alves, Paulo; Brindle, Ct; Call, Evan; Dealey, Carol; Santamaria, Nick
2014-10-01
This systematic review considers the evidence supporting the use of prophylactic dressings for the prevention of pressure ulcer. Electronic database searches were conducted on 25 July 2013. The searches found 3026 titles and after removal of duplicate records 2819 titles were scanned against the inclusion and exclusion criteria. Of these, 2777 were excluded based on their title and abstract primarily because they discussed pressure ulcer healing, the prevention and treatment of other chronic and acute wounds or where the intervention was not a prophylactic dressing (e.g. underpads, heel protectors and cushions). Finally, the full text of 42 papers were retrieved. When these 42 papers were reviewed, 21 were excluded and 21 were included in the review. The single high-quality randomised controlled trial (RCT) and the growing number of cohort, weak RCT and case series all suggest that the introduction of a dressing as part of pressure ulcer prevention may help reduce pressure ulcer incidence associated with medical devices especially in immobile intensive care unit patients. There is no firm clinical evidence at this time to suggest that one dressing type is more effective than other dressings. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Chronic Hepatitis C Therapy in Liver Cirrhosis Complicated by Telaprevir-Induced DRESS.
Mousa, Omar Y S; Khalaf, Rossa; Shannon, Rhonda L; Egwim, Chukwuma I; Zela, Scott A; Ankoma-Sey, Victor
2014-01-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare yet severe adverse drug-induced reaction with up to 10% mortality rate. Recent clinical trials reported an association between DRESS and telaprevir (TVR), an NS3/4A protease inhibitor of chronic hepatitis C (CHC) virus genotype 1. Its diagnosis is challenging given the variable pattern of cutaneous eruption and the myriad internal organ involvement. We present two patients who are middle-aged, obese, and white with CHC cirrhosis. They both developed a progressive diffuse, painful pruritic maculopapular rash at weeks 8 and 10 of CHC therapy with TVR, Peg-Interferon alfa-2a, and Ribavirin. They had no exposures to other medications that can cause this syndrome. Physical exam and labs and skin biopsy supported a "Definite" clinical diagnosis of DRESS, per RegiSCAR criteria. Thus Telaprevir-based triple therapy was discontinued and both patients experienced rapid resolution of the systemic symptoms with gradual improvement of eosinophilia and the skin eruption. These two cases illustrate the paramount importance of having a high index of suspicion for TVR-induced DRESS, critical for early diagnosis. Immediate discontinuation of TVR is essential in prevention of a potentially life-threatening complication. Risk factors for development of DRESS in patients receiving TVR remain to be elucidated.
Hermans, Michel H E; Kwon Lee, S; Ragan, Mitzie R; Laudi, Pam
2015-03-01
This retrospective observational study analyzed lesions with regard to healing trends and cost of materials. The observed lesions were mostly postsurgical or stage IV pressure ulcers in patients with serious morbidity. The wounds were treated with a hydrokinetic fiber dressing (sorbion Sachet S, sorbion Gmbh & Co, a BSN medical company, Senden, Germany) (n = 26) or negative pressure wound therapy (NPWT) (n = 16). Primary healing trends (ie, reduction of wound size, change from necrosis to granulation tissue, and change from granulation tissue to epithelium) and secondary healing trends (ie, periwound conditions) were similar for wounds treated with the hydrokinetic dressing when compared to wounds treated with NPWT. Cost of materials was substantially lower for wounds treated with the hydrokinetic fiber dressing compared to the NPWT, with cost reductions of $1,640 (348%) to $2,242 (1794%) per wound, depending on the criteria used for the analysis. In this set of wounds, the hydrokinetic fiber dressing was shown to lead to similar healing results while providing substantial reductions of the cost of materials. For the types of wounds presented in this observational study, the hydrokinetic fiber dressing seems to be an effective substitution for negative pressure wound therapy.
Lavery, Lawrence A; La Fontaine, Javier; Thakral, Gaurav; Kim, Paul J; Bhavan, Kavita; Davis, Kathryn E
2014-03-01
This study was designed to compare two approaches to negative-pressure wound therapy: 125-mmHg pressure with a polyurethane foam dressing and 75-mmHg pressure with a silicone-coated dressing. Forty patients with diabetic foot wounds, after incision and drainage or amputation for infection, were assigned randomly to negative-pressure wound therapy with 75-mmHg continuous pressure with a silicone-covered dressing (75-mmHg group) or 125-mmHg with a polyurethane foam dressing (125-mmHg group) for up to 4 weeks or until surgical closure. There was no difference in the proportion of wounds that were closed surgically (75-mmHg group, 50 percent; 125-mmHg group, 60 percent), wounds that demonstrated 50 percent wound area reduction (75-mmHg group, 65 percent; 125-mmHg group, 80 percent), or wounds that demonstrated 50 percent wound volume reduction after 4 weeks of therapy (75-mmHg group, 95 percent; 125-mmHg group, 90 percent). The authors' results suggest that there was no difference in outcomes in wounds treated with low pressure (75 mmHg) with a silicone-coated interface and high pressure (125 mmHg) with a polyurethane foam interface. Therapeutic, II.
Held, Manuel; Engelke, Anne-Sophie; Tolzmann, Dascha Sophie; Rahmanian-Schwarz, Afshin; Schaller, Hans-Eberhard; Rothenberger, Jens
2016-09-01
There is a high prevalence of superficial wounds such as partial-thickness burns. Treatment of these wounds frequently includes temporary application of wound dressings. The aim of this study was to compare a newly developed collagen matrix with commonly used temporary skin dressings for treatment of partial-thickness skin defects. Through a skin dermatome, 42 standardized superficial skin defects were generated on the back of 28 adult male Lewis rats. The wounds were treated with a synthetic wound dressing (Suprathel, Polymedics Innovations Inc, Woodstock, GA) (n = 14), a biosynthetic skin dressing (Biobrane, Smith & Nephew, Hull, UK) (n = 14), or a newly developed bovine collagen matrix, Collagen Cell Carrier (Viscofan BioEngineering, Weinheim, Germany) (n = 14). Biomechanical properties of the skin were determined and compared every 10 days over a 3-month period of using the Cutometer MPA 580 (Courage + Khazaka Electronic GmbH, Cologne, Germany). As opposed to healthy skin, statistically significant differences were detected between days 10 and 30, and between days 60 and 80, for calculated elasticity (Ue), firmness of skin (R0), and overall elasticity (R8). After 3 months, no statistically significant differences in skin elasticity were detected between the different wound dressings. The presented results give an opportunity to compare the wound dressings used for treatment with respect to skin elasticity and reveal the potential of the bovine collagen matrix in the treatment of superficial skin defects; therefore the results facilitate further evaluation of collagen matrix in surgical applications and regenerative medicine.
Muguregowda, Honnegowda Thittamaranahalli; Kumar, Pramod; Govindarama, Padmanabha Udupa Echalasara
2018-01-01
BACKGROUND Malondialdehyde (MDA) is an oxidant that causes damage to membranes, DNA, proteins, and lipids at the cellular level. Antioxidants minimize the effects of oxidants and thus help in formation of healthy granulation tissues with higher level of hydroxyproline and total protein. This study compared the effect of limited access dressing (LAD) with conventional closed dressing biochemically and histopathologically. METHODS Seventy-two 12-65 years old burn patients with mean wound size of 14 cm2 were divided to two groups of LAD (n=37), and conventional dressing groups (n=35). Various biochemical parameters were measured in granulation tissue. Histopathological analysis of the granulation tissue was studied too. RESULTS LAD group showed significant increase in hydroxyproline, total protein, GSH, and GPx and decrease in MDA levels compared to conventional dressing group. A significant negative correlation between GSH and MDA was noted in LAD group, but in conventional dressing group there was no significant correlation. A significant negative correlation between GPx and MDA was noticed in LAD group, but in conventional dressing group was not significant. There was a histologically fewer inflammatory cells, increased and well organized extracellular matrix deposit, more angiogenesis in LAD group after 10 days while the difference was significant between the groups. CONCLUSION Our study showed a significant reduction in oxidative stress biomarker of MDA, increase in hydroxyproline, total protein, antioxidants and amount of ECM deposition, number of blood vessels and a decrease in the amount of inflammatory cells and necrotic tissues in LAD group indicating the better healing effect of burn wounds. PMID:29651393
Applications of modern sensors and wireless technology in effective wound management.
Mehmood, Nasir; Hariz, Alex; Fitridge, Robert; Voelcker, Nicolas H
2014-05-01
The management of chronic wounds has emerged as a major health care challenge during the 21st century consuming, significant portions of health care budgets. Chronic wounds such as diabetic foot ulcers, leg ulcers, and pressure sores have a significant negative impact on the quality of life of affected individuals. Covering wounds with suitable dressings facilitates the healing process and is common practice in wound management plans. However, standard dressings do not provide insights into the status of the wound underneath. Parameters such as moisture, pressure, temperature and pH inside the dressings are indicative of the healing rate, infection, and wound healing phase. But owing to the lack of information available from within the dressings, these are often changed to inspect the wound, disturbing the normal healing process of wounds in addition to causing pain to the patient. Sensors embedded in the dressing would provide clinicians and nurses with important information that would aid in wound care decision making, improve patient comfort, and reduce the frequency of dressing changes. The potential benefits of this enabling technology would be seen in terms of a reduction in hospitalization time and health care cost. Modern sensing technology along with wireless radio frequency communication technology is poised to make significant advances in wound management. This review discusses issues related to the design and implementation of sensor technology and telemetry systems both incorporated in wound dressings to devise an automated wound monitoring technology, and also surveys the literature available on current sensor and wireless telemetry systems. Copyright © 2013 Wiley Periodicals, Inc.
Composite wound dressings of pectin and gelatin with aloe vera and curcumin as bioactive agents.
Tummalapalli, Mythili; Berthet, Morgane; Verrier, Bernard; Deopura, B L; Alam, M S; Gupta, Bhuvanesh
2016-01-01
Aloe vera and curcumin loaded oxidized pectin-gelatin (OP-Gel) matrices were used as antimicrobial finishes on nonwoven cotton fabrics to produce composite wound care devices. The drug release characteristics of the biocomposite dressings indicated that curcumin is released through a biphasic mechanism - erosion of the polymeric matrix, followed by diffusion, while aloe vera is released upon leaching of the polymeric matrix. A 50/50 composition of aloe vera/curcumin was used to fabricate OP-Gel-Aloe Curcumin dressings. However, contrary to our expectations, OP-Gel-Aloe Curcumin dressings exhibited lesser antimicrobial activity compared to OP-Gel-Aloe and OP-Gel-Curcumin dressings. The cytocompatibility of the fabricated dressings was evaluated using NIH3T3 mouse fibroblast cells. OP-Gel-Aloe treated fibroblasts had the highest viability, with the matrices providing a substrate for good cell attachment and proliferation. On the other hand, OP-Gel-Curcumin and OP-Gel-Aloe Curcumin seemed to have induced apoptosis in NIH3T3 cells. In vivo wound healing analysis was carried out using an excisional splint wound model on C57BL/6J mice. OP-Gel-Aloe treated wounds exhibited very rapid healing with 80% of the wound healing in just 8 days. Furthermore, aloe vera exerted a strong anti-inflammatory effect and prominent scar prevention. Histological examination revealed that an ordered collagen formation and neovascularization could be observed along with migration of nuclei. Therefore, OP-Gel-Aloe biocomposite dressings are proposed as viable materials for effective wound management. Copyright © 2015 Elsevier B.V. All rights reserved.
SU-F-T-379: Dosimetric Impacts of Topical Agents and Dressings On Skin in Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tse, K; Morley, L; Cashell, A
Purpose: This study investigated the superficial dose enhancement in the application of topical agents, clinical materials (thermal mask and bolus) and dressings in megavoltage photon beam radiotherapy. Different topical skin agents, clinical materials and dressings were evaluated and compared for their skin dosimetric impacts on the patients during radiation treatment. Methods: Superficial dose enhancements, or percentage doses with and without the studying materials, were measured using the 6 MV (Field size = 10×10 cm{sup 2}) photon beams produced by a Varian TrueBeam linear accelerator. Twelve topical agents, five dressings (dry and wet conditions) and three clinical materials were studied. Amore » solid water phantom was used with a MOSFET dose detector (TN-1002RD, Thomson and Nielsen Electronic, Ottawa, Ontario, Canada) located under a 1-mm PMMA slab to measure the skin dose. The distance between the radiation source and phantom surface was set to 100 cm in all measurements. The topical agents were distributed evenly with 1.5 mm thickness using our specific sample holder on the phantom surface. Extrapolations were made of 0.5 mm thickness for the agents to provide meaningful clinical value. Results: By comparing surface doses without studying materials, it is found that no topical agents had superficial dose enhancement higher than the clinical materials namely, thermoplastic mask (128%), 5-mm Superflab™ bolus (158%) and 10-mm Superflab™ bolus (171%) regarding the same thickness. Superficial dose enhancement of dry dressing did not exceed 110.5%, while wet dressings produced higher dose enhancements (133% for wet Mepilex lite and 141% for wet Mepilex Ag transfer). Conclusion: It is concluded that the evaluated topical agents and dry dressings did not increase the superficial dose to a concerning level, even using excessive thickness in every fraction of radiation treatment. Wet dressings were found producing the bolus effect, but was still substantially less than applying a thin 5-mm bolus.« less
Ondieki, J G; Khainga, S O; Owilla, F; Nangole, F W
2012-07-01
Wounds have provided a challenge to the clinicians for centuries and this scenario persists to the 21st century. Negative pressure wound therapy (NPWT) is one of the latest additions in wound management. It has been widely adopted in developed countries with foam as the default wound dressing although it has some limitations. To determine the difference in outcomes between the use of gauze versus foam as wound dressing in NPWT for the management of acute traumatic wounds with soft tissue loss. Prospective randomised comparative interventional study. Kenyatta National Hospital Orthopaedic and Surgical wards. All patients aged above 12 years with Class III and Class IV acute traumatic wounds. The main outcome measure is the time taken to achieve 100% wound granulation. Comparisons were also made on the mean pain scores during dressing change and the percentage change in wound surface area. Wounds took an average of 8.4 days in the gauze group and 8.1 days in the foam group (p = 0.698) to achieve full granulation. The percentage change in wound surface area was 5.3 versus 5.5 (P = 0.769) in the gauze and foam groups respectively. The infection rates were comparable between the two groups (28% for gauze and 23.1% for foam, p = 0.697) and there was no significant difference in the median pain scores (gauze = 4.5, foam = 4.8 with p = 0.174). However, outcomes with gauze dressing were influenced significantly by the time to application of NPWT, initial wound surface area and wound infection while with foam dressing outcomes tended to be affected less so by the above factors. In the use of NPWT for the management of acute traumatic wounds, there is no difference in terms of time to full wound granulation, change in wound surface area, wound infection and pain during dressing change whether gauze or foam is used as the wound dressing material.
Meekul, Jarernchon; Chotirosniramit, Arnon; Himakalasa, Woraluck; Orrapin, Saritphat; Wongthanee, Antika; Pongtam, Orapin; Kulprachakarn, Kanokwan; Rerkasem, Kittipan
2017-06-01
Necrotizing fasciitis (NF) is a high morbidity and mortality disease and also demands high economic resources. The standard treatment of NF is surgical debridement and proper dressing for wound bed preparation. The efficacy of silver alginate dressing can inhibit the growth of microorganisms and keep the environment clean for wound bed preparation. However an optimal dressing to manage such wounds has yet to emerge. NF patients who were admitted between April 2013 and May 2016 were randomized to have wound dressing using either silver dressing (Ag group) or normal saline solution gauze (NSS group). The 4 main outcomes for comparison between the 2 groups were the duration of wound bed preparation, total cost during hospital stay, the duration of hospital stay, and the pain score. Thirty-nine patients were included in the study: 19 patients in the NSS group and 20 patients in the Ag group. The mean duration of wound bed preparation in the NSS group was 31.87 days, and in Ag group it was 21.39 days, but this trend was not statistically significant ( P = .057). The mean cost of treatment in the NSS and Ag groups was not significantly different ( P = .434; US$3308.83 and US$2647.82, respectively). The duration of hospital days in the 2 groups was not significantly different either (29.19 days [NSS group] and 20.99 days [Ag group]; P = .222). The pain score was significantly lower in the Ag group than those in the NSS group. Although silver dressing seems to be expensive, the cost of total treatment during hospital stay and the duration of hospital stay were not significantly different between groups. However, the mean duration of wound bed preparation seems to trend favoring toward the silver dressing group.
Thilmann, C; Adamietz, I A; Ramm, U; Mose, S; Saran, F; Böttcher, H D
1996-05-01
Silicone-coated polyamide wound dressing is frequently used for the supportive treatment in patients with radiation induced skin lesions. The use of this kind of dressing during radiotherapy with high energy beams shifts the dose built-up effect towards the skin surface. Thus the dose delivered to the skin increases. The present work quantifies changes of the skin dose by a commercial silicon-coated polyamide wound dressing. The dependence on the beam quality and on different treatment techniques is investigated. Measurements were performed with photon (60Co, 6 MV, 42 MV) and electron (7 MeV, 20 MeV, 40 MeV) beams using thin LiF thermoluminescence dosimeters (TLD) in a perspex phantom. The beams were directed perpendicularly to the phantom surface. For 60Co and 6 MV photon beams the skin dose was evaluated in vivo at different beam arrangements and at a given reference dose. For 60Co, 6 MV and 42 MV photon beams wound dressing caused a dose increase on the surface of the perspex phantom by a factor of 1.65, 1.39 and 1.33 respectively. Using oblique or rotational techniques for 60Co and 6 MV photon irradiation the wound dressing increased the skin dose but less compared to perpendicular beam direction. For electron beams the skin dose is relatively high (from 84% to 92%) and an increase by a dressing has no clinical relevance (factor 1.03 to 1.05). The silicone-coated polyamide wound dressing causes no relevant skin dose increase during radiation treatment with electron beams and can be left on the skin during irradiation. During radiation treatment with photon beams like 60Co and 6 MV the protective procedure should be adapted to skin changes, in case of strong skin reactions a removal during the time of irradiation should be considered.
Metcalf, Daniel G; Parsons, David; Bowler, Philip G
2017-02-01
The objective of this work was to evaluate the safety and effectiveness of a next-generation antimicrobial wound dressing (NGAD; AQUACEL ® Ag+ Extra™ dressing) designed to manage exudate, infection and biofilm. Clinicians were requested to evaluate the NGAD within their standard protocol of care for up to 4 weeks, or as long as deemed clinically appropriate, in challenging wounds that were considered to be impeded by suspected biofilm or infection. Baseline information and post-evaluation dressing safety and effectiveness data were recorded using standardised evaluation forms. This data included wound exudate levels, wound bed appearance including suspected biofilm, wound progression, skin health and dressing usage. A total of 112 wounds from 111 patients were included in the evaluations, with a median duration of 12 months, and biofilm was suspected in over half of all wounds (54%). After the introduction of the NGAD, exudate levels had shifted from predominantly high or moderate to low or moderate levels, while biofilm suspicion fell from 54% to 27% of wounds. Wound bed coverage by tissue type was generally shifted from sloughy or suspected biofilm towards predominantly granulation tissue after the inclusion of the NGAD. Stagnant (65%) and deteriorating wounds (27%) were shifted to improved (65%) or healed wounds (13%), while skin health was also reported to have improved in 63% of wounds. High levels of clinician satisfaction with the dressing effectiveness and change frequency were accompanied by a low number of dressing-related adverse events (n = 3; 2·7%) and other negative observations or comments. This clinical user evaluation supports the growing body of evidence that the anti-biofilm technology in the NGAD results in a safe and effective dressing for the management of a variety of challenging wound types. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Bennett, Brad L; Littlejohn, Lanny F; Kheirabadi, Bijan S; Butler, Frank K; Kotwal, Russ S; Dubick, Michael A; Bailey, Jeffrey A
2014-01-01
Hemorrhage remains the leading cause of combat death and a major cause of death from potentially survivable injuries. Great strides have been made in controlling extremity hemorrhage with tourniquets, but not all injuries are amenable to tourniquet application. Topical hemostatic agents and dressings have also contributed to success in controlling extremity and compressible junctional hemorrhage, and their efficacy continues to increase as enhanced products are developed. Since the addition of Combat Gauze™ (Z-Medica Corporation, Wallingford, CT, USA; http://www.z-medica.com/) in April 2008 to the Tactical Combat Casualty Care (TCCC) Guidelines, there are consistent data from animal studies of severe hemorrhage that chitosan-based hemostatic gauze dressings developed for battlefield application are, at least, equally efficacious as Combat Gauze. Successful outcomes are also reported using newer chitosan-based dressings in civilian hospital-based surgical case reports and prehospital (battlefield) case reports and series. Additionally, there have been no noted complications or safety concerns in these cases or across many years of chitosan-based hemostatic dressing use in both the military and civilian prehospital sectors. Consequently, after a decade of clinical use, there is added benefit and a good safety record for using chitosan-based gauze dressings. For these reasons, many specific US military Special Operations Forces, NATO militaries, and emergency medical services (EMS) and law enforcement agencies have already implemented the widespread use of these new recommended chitosan-based hemostatic dressings. Based on the past battlefield success, this report proposes to keep Combat Gauze as the hemostatic dressing of choice along with the new addition of Celox™ Gauze (Medtrade Products Ltd., Crewe, UK; http://www.celoxmedical.com/usa/products /celox-gauze/) and ChitoGauze® (HemCon Medical Technologies, Portland, OR, USA; http://www.hemcon.com/) to the TCCC Guidelines. 2014.
Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T
2018-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.
Exact asymmetric Skyrmion in anisotropic ferromagnet and its helimagnetic application
NASA Astrophysics Data System (ADS)
Kundu, Anjan
2016-08-01
Topological Skyrmions as intricate spin textures were observed experimentally in helimagnets on 2d plane. Theoretical foundation of such solitonic states to appear in pure ferromagnetic model, as exact solutions expressed through any analytic function, was made long ago by Belavin and Polyakov (BP). We propose an innovative generalization of the BP solution for an anisotropic ferromagnet, based on a physically motivated geometric (in-)equality, which takes the exact Skyrmion to a new class of functions beyond analyticity. The possibility of stabilizing such metastable states in helimagnets is discussed with the construction of individual Skyrmion, Skyrmion crystal and lattice with asymmetry, likely to be detected in precision experiments.
Non-AdS holography in 3-dimensional higher spin gravity — General recipe and example
NASA Astrophysics Data System (ADS)
Afshar, H.; Gary, M.; Grumiller, D.; Rashkov, R.; Riegler, M.
2012-11-01
We present the general algorithm to establish the classical and quantum asymptotic symmetry algebra for non-AdS higher spin gravity and implement it for the specific example of spin-3 gravity in the non-principal embedding with Lobachevsky ( {{{{H}}^2}× {R}} ) boundary conditions. The asymptotic symmetry algebra for this example consists of a quantum W_3^{(2) } (Polyakov-Bershadsky) and an affine û(1) algebra. We show that unitary representations of the quantum W_3^{(2) } algebra exist only for two values of its central charge, the trivial c = 0 "theory" and the simple c = 1 theory.
NASA Astrophysics Data System (ADS)
Polyakov, V. V.
During a final 4-month stage of I-year space flight of cosmonauts Titov and Manarov, a physician, Valery Polyakov was included on a crew for the purpose of evaluating their health, correcting physical status to prepare for the spacecraft reentry and landing operations. The complex program of scientific investigations and experiments performed by a physician included an evaluation of adaptation reactions of the human body at different stages of space mission using clinicophysiological and biochemical methods; testing of alternative regimes of exercises and new countermeasures to prevent an unfavorable effect of long-term weightlessness.
Vignesh, Pandiarajan; Kishore, Janak; Kumar, Ankur; Vinay, Keshavamurthy; Dogra, Sunil; Sreedharanunni, Sreejesh; Prasun Giri, Prabhas; Pal, Priyankar; Ghosh, Apurba
2017-05-01
Drug rash, eosinophilia, and systemic symptoms (DRESS) syndrome is a severe systemic hypersensitivity reaction that usually occurs within 6 weeks of exposure to the offending drug. Diagnosis is usually straightforward in patients with pyrexia, skin rash, hepatitis, and eosinophilia with a preceding history of exposure to agents often associated with DRESS syndrome, such as aromatic anticonvulsants and sulfa drugs, but diagnosis of DRESS may still be a challenge. We report a 4-year-old child with probable DRESS syndrome complicated by multiple hematologic complications that developed 1 month after exposure to fluoxetine, a drug not known to be associated with such severe reactions. © 2017 Wiley Periodicals, Inc.
Reducing pain in acute herpes zoster with plain occlusive dressings: a case report.
Keegan, David A
2015-04-25
The pain of acute herpes zoster (shingles) is severe and difficult to control. The medications used to control pain have a variety of important and potentially serious side effects. To the best of my knowledge, this is the first case report of using a plain topical occlusive dressing to reduce the pain of herpes zoster, avoiding the use of medication. A 40-year-old Caucasian man and a qualified physician (the author), developed a dermatomal vesicular rash consistent with herpes zoster. Applying plain topical occlusive dressings reduced the severity of his pain to an ignorable level. Plain topical occlusive dressings provide effective pain relief for acute herpes zoster, thereby avoiding the risks accompanying medication use.
Kazanavičius, M; Cepas, A; Kolaityte, V; Simoliuniene, R; Rimdeika, R
2017-06-02
To identify the most appropriate, most suitable and most efficient dressing for split-thickness skin graft (STSG) donor sites. Comparing the wound healing rate, pain severity and duration, as well as the dressing change frequency in four randomised patient groups. A single-centre non-blinded randomised controlled trial was carried out during 2010-2014. All patients treated for skin defects/lesions (due to burns, trauma or ulcers) using STSG were included in the study. All patients were randomly allocated in four different donor site treatment groups; polyurethane (PU group, Mepilex); polyurethane with silicone membrane (PUSM group; Mepilex border,); transparent, breathable film (TBF group; Mepitel film) and cotton gauze dressings (CG group) using Excel 2007. We evaluated: wound healing time, pain severity and duration, the frequency of dressing change, donor site re-epithelialisation, donor site complications (signs of inflammation or infection). Patients were assessed on postoperative days: 1, 3, 6, 9, 12, 15, 18 and 21. After random allocation of study participants the number of patients in each group were: PU group n=25; PUSM group n=24; TBF group n=24; CG group n=25. The groups were homogenous according to gender, age, main pathology, donor site area and wound size. The STSG donor site healing time varied from 9 to 21 days. The mean healing time in the CG group was 14.76 days, whereas in the PU, PUSM, and TBF group it was significantly shorter; 12.25 days, 11.63 days and 10 days, respectively. Patients in the TBF group demonstrated the most rapid healing time with 66.7% of STSG donor sites healed by postoperative day 9. The pain duration interval in modern dressing groups (PU, PUSM and TBF groups) was 0-9 days, whereas it was 6-18 day in the CS group. Pain intensity mean on postoperative day 1 was 2.21 in the PU group; 1.67 in the PUSM group; 1.46 in the TBF group and 3.04 in the CG group. The average pain duration in Group PU, PUSM, and TBF was 4.08 days; 2.5 days; 2.29 days, respectively. The average number of times each dressing was changed in each group was, 2.83 times in the PU group and PUSM group and 1.46 times in the TBF group. The CG dressing group were changed once when the donor site wound re-epithelialised. There was one patient in the PU group who experienced signs of infection, was treated accordingly and excluded from the study. The fastest healing time was demonstrated by patients in the TBF group. The pain was not as severe and for a shorter period of time in modern dressing study groups. However, the pain was lightest and felt shortest in TBF dressing group. The modern dressings PU and PUSM had to be changed more frequently than TBF.
NASA Astrophysics Data System (ADS)
Zanchettin, D.; Jungclaus, J. H.
2013-12-01
Large multidecadal fluctuations in basin-average sea-surface temperature (SST) are a known feature of observed, reconstructed and simulated variability in the North Atlantic Ocean. This phenomenon is often referred to as Multidecadal Atlantic Variability or AMV. Historical AMV fluctuations are associated with analog basin-scale changes in sea-surface salinity, so that warming corresponds to salinification and cooling to freshening [Polyakov et al., 2005]. The surface imprint of the AMV further corresponds to same-sign fluctuations in the shallow ocean and with opposite-sign fluctuations in the deep ocean for both temperature and salinity [Polyakov et al., 2005]. This out-of-phase behavior reflects the thermohaline overturning circulation shaping North Atlantic's low-frequency variability. Several processes contribute to the AMV, involving both ocean-atmosphere coupled processes and deep ocean circulation [e.g., Grossmann and Klotzbach, 2009]. In particular, recirculation in the North Atlantic subpolar gyre region of salinity anomalies from Arctic freshwater export may trigger multidecadal variability in the Atlantic meridional overturning circulation, and therefore may be part of the AMV [Jungclaus et al., 2005; Dima and Lohmann, 2007]. With this contribution, we aim to improve the physical interpretation of the AMV by investigating spatial and temporal patterns of temperature and salinity fields in the shallow and deep ocean. We focus on two unperturbed millennial-scale simulations performed with the Max Planck Institute Earth system model in its paleo (MPI-ESM-P) and low-resolution (MPI-ESM-LR) configurations, which provide reference control climates for assessments of pre-industrial and historical climate simulations. The two model configurations only differ for the presence, in MPI-ESM-LR, of an active module for dynamical vegetation. We use spatial-average indices and empirical orthogonal functions/principal components to track the horizontal and vertical propagation of temperature and salinity anomalies related to the AMV. In particular, we discuss the potential predictability of multidecadal fluctuations in North Atlantic SSTs based on indices derived from the sea-surface salinity field. We show how the two simulations provide AMV realizations with some distinguishable characteristics, e.g., the typical fluctuations' frequencies and the linkage with the North Atlantic meridional overturning and gyre circulations. We further show how information gained by investigating different definitions of the AMV [Zanchettin et al., 2013] helps designing numerical sensitivity studies for understanding the mechanism(s) behind this phenomenon, concerning both its origin and global impacts. References Dima, M., and G. Lohmann [2007], J. Clim., 20, 2706-2719, doi:10.1175/JCLI4174.1 Jungclaus, J.H., et al. [2005], J. Clim., 18, 4013- 4031, doi:10.1175/JCLI3462.1 Polyakov, I. V., et al. [2005], J. Clim., 18:4562-4581 Grossmann, I., and P. J. Klotzbach [2009], J. Geophys. Res., 114, D24107, doi:10.1029/2009JD012728 Zanchettin D., et al. [2013], Clim. Dyn., doi:10.1007/s00382-013-1669-0
Yunoki, Shunji; Kohta, Masushi; Ohyabu, Yoshimi; Iwasaki, Tetsuji
2015-01-01
This study evaluated the in vitro antibacterial activity and cytotoxicity of various commercially available silver-containing dressings (Ag dressing). Biohesive Ag (hydrocolloid, silver sulfadiazine), Aquacel® Ag (nonwoven fabric, ionic silver [Ag]), Algisite™ Ag (nonwoven fabric, Ag), Mepilex® Ag (foam, silver sulfate), and PolyMem® Ag (foam, nanocrystalline silver) were tested for characteristics of Ag release, antibacterial activity, and cytotoxicity. The release of Ag was investigated in cell culture medium at immersion periods of 6, 24, and 48 hours. The antibacterial activity against Staphylococcus aureus and Pseudomonas aeruginosa were accessed by a disc diffusion test. The cytotoxicity was evaluated using V79 cells, by an extraction method. The cytotoxicity was not a monotonic function of the antibacterial activity among the Ag dressings and could not be simply explained by Ag-release properties. Biohesive Ag was regarded as a slow-release Ag dressing, showing the lowest cytotoxicity, while the antibacterial activity was classified as "strong" or "significant" against the two species of bacteria. Aquacel Ag and Algisite Ag showed higher antibacterial activity and cytotoxic effects, which were supported by the higher Ag release. Mepilex Ag showed the highest release of Ag, and the cytotoxicity was the highest among the Ag dressings. However, the antibacterial activity was classified as "significant" or "no activity" for P. aeruginosa and S. aureus, respectively. PolyMem Ag showed the lowest Ag release, and the antibacterial activity classified as "significant" or "no activity" for S. aureus and P. aeruginosa, respectively, whereas the cytotoxicity was similar to those of Aquacel Ag and Algisite Ag. The efficacy and adverse effects of the Ag dressings revealed differences that should be considered by clinicians during wound management.
Evaluation of Six Split-thickness Skin Graft Donor-site Dressing Materials in a Swine Model
Masella, Pamela C.; Balent, Eric M.; Carlson, Terri L.; Lee, Karen W.
2013-01-01
Background: Numerous dressings for split-thickness skin graft donor sites are commercially available with no conclusive evidence-based consensus regarding the optimal dressing choice. This study was conducted to identify which of 5 commonly used materials promotes wound healing most effectively for use on split-thickness donor sites in comparison with our standard dressing, Xeroform (petrolatum gauze). Methods: Twenty-four partial-thickness wounds were created on the backs of 4 pigs using a dermatome. Wounds (n = 4 per dressing type per pig) were treated with Xeroform, Opsite (polyurethane film), Kaltostat ( calcium sodium alginate), DuoDERM (hydrocolloid), Aquacel (hydrofiber), and Mepilex (silicone foam). Full-thickness skin samples were excised at 3 or 5 days and evaluated histologically for reepithelialization and inflammation. Comparisons also included incidence of infection, ease of use, and cost analyses. Results: DuoDERM elicited the greatest percent reepithelialization (81%) and Mepilex the lowest (33%) after 3 days (P = 0.004). All dressings demonstrated complete reepithelialization except Mepilex (85%) at 5 days. There were no infections and inflammation was mild among all treatments. Mepilex was easiest to use, whereas Aquacel, Kaltostat, and Opsite were most difficult (P = 0.03). Xeroform was most cost-effective and Aquacel most expensive. Combined scoring revealed DuoDERM = Xeroform > Opsite = Mepilex > Kaltostat > Aquacel. Conclusions: DuoDERM and Xeroform were most effective overall. DuoDERM tended to outperform all dressings in reepithelialization at 3 days, while Xeroform was least expensive, easy to use, and demonstrated rapid reepithelialization. These findings suggest that Xeroform may be preferred for use on large donor-site areas. DuoDERM may be more appropriate for small donor sites when healing time is a priority. PMID:25289278
Does the Use of Clean or Sterile Dressing Technique Affect the Incidence of Wound Infection?
Kent, Dea J; Scardillo, Jody N; Dale, Barbara; Pike, Caitlin
The purpose of this article is to examine the evidence and provide recommendations for the use of clean or sterile dressing technique with dressing application to prevent wound infection. In all persons with acute or chronic wounds, does the use of clean or sterile dressing technique affect incidence of wound infection? A search of the literature was performed by a trained university librarian, which resulted in 473 articles that examined any age group that dealt with application of a wound dressing using either sterile or nonsterile technique. A systematic approach was used to review titles, abstracts, and text, yielding 4 studies that met inclusion criteria. Strength of the evidence was rated using rating methodology from Essential Evidence Plus: Levels of Evidence and Oxford Center for Evidence-Based Medicine, adapted by Gray and colleagues. Johns Hopkins Nursing Evidence-Based Practice Nursing Research Appraisal Tool was used to rate the quality of the evidence. All 4 studies reported no significant difference in the rate of wound infection when using either clean or sterile technique with dressing application. The strength of the evidence for the identified studies was identified as level 2 (1 level A, 3 level B). The study sizes were variable, and the wounds included do not represent the continuum of wounds clinically encountered across the board. Evidence indicates that the use of clean technique for acute wound care is a clinically effective intervention that does not affect the incidence of infection. There is no recommendation that can be made regarding type of dressing technique for a chronic wound due to the lack of evidence in the literature.
Evaluation of Antimicrobial and Healing Activities of Frog Skin on Guinea Pigs Wounds
Rezazade Bazaz, Mahere; Mashreghi, Mohammad; Mahdavi Shahri, Nasser; Mashreghi, Mansour; Asoodeh, Ahmad; Behnam Rassouli, Morteza
2015-01-01
Background: Frog skin secretions have potentials against a wide spectrum of bacteria. Also, frog skin compositions have healing properties. Objectives: The aim of this study was to investigate the antibacterial potentials along with healing properties of frog skin Rana ridibunda, a species which thoroughly lives in Iran marshes, as a biological dressing on wounds. Materials and Methods: In this study, excisional wounds, dressed with frog skin, were compared between experimental and control groups of guinea pigs. In the experimental groups, wounds were dressed with the dermal (FS) and epidermal (RFS) sides of fresh frog R. ridibunda skin, while only usual cotton gauze covered the wounds of the control group. Furthermore, microbial samples were taken on different days (0, 3, 5, and 7 days post injury) to count the number of the colony-forming units. Additionally, the microbial penetration test was performed on frog skin and then the progression of wound closure was evaluated. Results: In the microbial studies, the bacterial load considerably declined in the wounds treated with FS and RFS compared with the control wounds. On day 7 post injury, the numbers of the colony-forming units for the FS, RFS, and control groups were 6.75, 105, and 375, respectively. In the penetration test, fresh frog skin showed to be a bacterial resistant dressing. The results revealed that the rate of wound closure in the experimental groups significantly was accelerated in comparison with that in the control group. Conclusions: Our results demonstrated the antimicrobial properties of frog skin as a wound dressing, which has antimicrobial effects per se. This biological dressing shows promise as an effective biological wound dressing insofar as not only is it capable of resisting microbes and accelerating wound healing but also it is cost-effective and easy to use. PMID:26468364
Kellar, Robert S; Audet, Robert G; Roe, David F; Rheins, Lawrence A; Draelos, Zoe Diana
2013-06-01
As oxygen is essential for wound healing and there is limited diffusion across the stratum corneum into the epidermis, we wanted to evaluate whether the topical delivery of a total dissolved oxygen in dressing form on intact human subject skin would improve clinical and histologic skin functioning. Fifty normal, healthy subjects completed a pilot clinical evaluation to assess the efficacy and tolerability of a dissolved oxygen dressing (OxygeneSys™-Continuous) to improve the health and appearance of intact skin. Clinical analysis was performed on 50 subjects; histological and gene expression analysis was performed on 12 of the 50 subjects to assess the effect of the dissolved oxygen dressing. Clinical data demonstrate that the dressing is well tolerated, and several measures of skin health and integrity showed improvements compared with a control dressing site. Skin hydration measurements showed a statistically significant increase in skin hydration at 0-4, 4-8, and 0-8 weeks (P < 0.05 at each time point). The blinded clinical investigator's grading of desquamation, roughness, and skin texture show significant decreases from baseline to the 8-week time point (P < 0.05). The dressings were removed prior to the blinded clinical investigator's grading. These data were supported by the histological and gene expression studies, which showed a general reduction in inflammatory response markers and transcription products (IL-6, IL-8, TNF-alpha, MMP-1, and MMP-12), while facilitating a general increase in structural skin proteins (collagen I, elastin, and filaggrin). Additionally, p53 signals from biopsy samples support the clinical investigator's observations of no safety concerns. The data from this study demonstrate that the dressing has no deleterious effects and stimulates beneficial effects on intact, nonwounded skin. © 2013 Wiley Periodicals, Inc.
Wound Dressings and Comparative Effectiveness Data
Sood, Aditya; Granick, Mark S.; Tomaselli, Nancy L.
2014-01-01
Significance: Injury to the skin provides a unique challenge, as wound healing is a complex and intricate process. Acute wounds have the potential to move from the acute wound to chronic wounds, requiring the physician to have a thorough understanding of outside interventions to bring these wounds back into the healing cascade. Recent Advances: The development of new and effective interventions in wound care remains an area of intense research. Negative pressure wound therapy has undoubtedly changed wound care from this point forward and has proven beneficial for a variety of wounds. Hydroconductive dressings are another category that is emerging with studies underway. Other modalities such as hyperbaric oxygen, growth factors, biologic dressings, skin substitutes, and regenerative materials have also proven efficacious in advancing the wound-healing process through a variety of mechanisms. Critical Issues: There is an overwhelming amount of wound dressings available in the market. This implies the lack of full understanding of wound care and management. The point of using advanced dressings is to improve upon specific wound characteristics to bring it as close to “ideal” as possible. It is only after properly assessing the wound characteristics and obtaining knowledge about available products that the “ideal” dressing may be chosen. Future Directions: The future of wound healing at this point remains unknown. Few high-quality, randomized controlled trials evaluating wound dressings exist and do not clearly demonstrate superiority of many materials or categories. Comparative effectiveness research can be used as a tool to evaluate topical therapy for wound care moving into the future. Until further data emerge, education on the available products and logical clinical thought must prevail. PMID:25126472
Evaluation of three-layered doxycycline-collagen loaded nanofiber wound dressing.
Tort, Serdar; Acartürk, Füsun; Beşikci, Arzu
2017-08-30
Nanofiber wound dressings have great potential for both acute and chronic wound healing. The aim of this study is to develop a wound dressing by the electrospinning method and to determine its in vitro characteristics. The viscosity and the surface tension values of the polymer solutions used in the electrospinning were measured and their suitability for electrospinning was evaluated. Nanofiber wound dressing consists of three layers. The first and the second layers are sodium alginate and chitosan nanofibers, respectively. The core of the coaxial nanofibers that comprises the third layer of the wound dressing contains 1% polycaprolactone and 4.5% collagen, the shell comprises 2.5% doxycycline and 2.5% polyethylene oxide. The developed wound dressing comprises aligned nanofibers, with a contact angle of 38°, a work of bioadhesion value of 0.485mJ/cm 2 on rat skin, a tensile strength of 2.76MPa, an elongation at break value of 7.65%, a specific surface area of 9.65m 2 /g and a porosity of 52.3%. The amount of doxycycline content was found to be 260μg/cm 2 and the complete drug release was achieved in 15min. No cytotoxic effect was shown in cell culture studies with keratinocyte cell lines. As a result of the stability studies, it was found that the morphological, mechanical, bioadhesion and wettability properties and the amount of doxycycline remained stable for a period of 12 months at 4°C/ambient humidity condition. The developed three-layered wound dressing could be an alternative for wound healing applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Sulthiame-induced drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome.
Fong, Choong Yi; Hashim, Nurmaira; Gan, Chin Seng; Chow, Tak Kuan; Tay, Chee Geap
2016-11-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a rare and potentially life-threatening acute drug-induced hypersensitivity reaction. Antiepileptic drugs (AEDs) predominantly aromatic AEDs are commonly reported in DRESS. To date there are no reports of sulthiame AED causing DRESS syndrome. We report a 10-year-old girl of Indian descent with AED resistant epilepsy on maintenance sodium valproate and clonazepam. Sulthiame AED was initiated to try to improve her seizure control. Five weeks after commencing sulthiame, she developed fever with a diffuse erythematous morbilliform maculopapular rash, elevated transaminases and atypical lymphocytes. At day 3 of illness, she deteriorated with worsening elevation of liver transaminases, thrombocytopenia, progression of rash, hepatosplenomegaly, pneumonitis and markedly elevated inflammatory markers. Immunomodulatory treatment of pulse methylprednisolone was given from day 7 which was associated with improvement inflammatory markers and complete resolution of rash from day 30 of illness. The diagnosis of sulthiame-induced DRESS syndrome was made based on clinical, laboratory and skin histology findings. She was HLA-B heterozygous for HLA-B ∗ 15:123 and 15:240 and HLA-A homozygous for HLA-A ∗ 11:01:09. Both these HLA-A and HLA-B typing has not been reported before in cutaneous drug reactions. This is the first reported case of sulthiame-induced DRESS syndrome. Our case expands the list of possible susceptible HLA alleles associated with cutaneous drug reactions. It also raises the awareness of possible DRESS syndrome among patients commenced on sulthiame who will require immediate discontinuation of sulthiame and consideration of prompt treatment of corticosteroids. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
A systematic review of silver-releasing dressings in the management of infected chronic wounds.
Lo, Shu-Fen; Hayter, Mark; Chang, Chee-Jen; Hu, Wen-Yu; Lee, Ling-Ling
2008-08-01
This paper is a systematic review with the objective of determining the effectiveness of silver-releasing dressing in the management of infected chronic wounds. Chronic wounds exhibit increased bacterial burdens which not only result in a negative physical impact on patients, impairing their quality of life, but also increase treatment costs. Silver dressings are wound products designed to control and inhibit infection and provide a wound environment conducive to healing. However, there is limited evidence on their effectiveness in doing so. A systematic review of literature from 1950-May 2007 was conducted using the PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO Host, OCLC, Proquest and PsychInfo databases. The review included randomised or non-randomised control trials, published in English or non-English, of silver-releasing dressings in infected chronic wounds. Of the over 1957 potentially releasing studies examined, 14 pertinent articles involving 1285 participants were identified. Almost all the participants reported one or more statistically significant outcomes. The main points to emerge from this review of studies are that silver-releasing dressings show positive effects on infected chronic wounds. The quality of the trials was limited by the potential for bias associated with inadequate concealment, no detailed description of the outcome measurement and no reported intention-to-treat analysis. Moreover, problems existed in some studies with confounding factors. The review clearly highlights the need for well-designed, methodologically standardised outcome measurement research into the effectiveness of silver-releasing dressings. It also points to the need for a comprehensive assessment of wound bed status in further studies. This review strengthens the case for the use of silver dressings when managing infected chronic wounds. They appear more effective and are tolerated well by patients. However, their use should be accompanied by a comprehensive wound assessment.
Padula, William V
The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. Retrospective observational cohort. We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (-1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (-1.13 cases/quarter; P = .035). Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products.
2017-01-01
PURPOSE: The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. DESIGN: Retrospective observational cohort. SAMPLE AND SETTING: We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. METHODS: We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. RESULTS: Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (−1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (−1.13 cases/quarter; P = .035). CONCLUSIONS: Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products. PMID:28816929
New hemostatic agents in the combat setting.
Cox, E Darrin; Schreiber, Martin A; McManus, John; Wade, Charles E; Holcomb, John B
2009-12-01
Hemorrhage is a leading cause of potentially preventable death in both civilian and military trauma patients. Animal data have shown that hemostatic bandages reduce hemorrhage and improve survival. This article reports recent clinical observations regarding the efficacy and evolution of use of two new hemostatic bandages employed in the global war on terrorism. We performed a retrospective cohort review of soldiers treated with either the QuikClot or HemCon hemostatic bandages between April and October 2006. Hemostatic dressings were placed on wounds either in the field or at the combat support hospital (CSH). During the 6-month study period, 1691 trauma patients were admitted to the CSH. Fifty uses of hemostatic dressings in 44 patients (2.6% of admissions) were identified. Forty patients were treated with HemCon dressings, three patients with QuikClot, and one with both QuikClot and HemCon. Eighteen percent of the dressings were used in the field, predominantly on extremity wounds (7/8). In contrast, most dressings used in the CSH were for truncal wounds (26/36 patients). Hemostatic dressings were applied to extremity wounds in prehospital and hospital settings, either alone or in conjunction with tourniquets. In surviving patients (95%), the treating surgeon determined that the hemorrhage was either stopped or greatly decreased by use of hemostatic dressings. Two of the four patients treated with QuikClot had burns from exothermic reactions, while no adverse reactions were noted with HemCon. Hemostatic agents stop or decrease bleeding. Whereas HemCon appears to be safe, QuikClot may produce superficial burns. These new hemostatic agents have a place in the surgical armamentarium to assist in controlling internal hemorrhage from truncal and pelvic hemorrhage, especially during damage-control surgery.
Chopra, Karan; Gowda, Arvind U; Morrow, Chris; Holton, Luther; Singh, Devinder P
2016-04-01
Complex abdominal wall reconstruction is beset by postoperative complications. A recent meta-analysis comparing the use of closed-incision negative-pressure therapy to standard dressings found a statistically significant reduction in surgical-site infection. The use of closed-incision negative-pressure therapy is gaining acceptance in this population; however, the economic impact of this innovative dressing remains unknown. In this study, a cost-utility analysis was performed assessing closed-incision negative-pressure therapy and standard dressings following closure of abdominal incisions in high-risk patients. Cost-utility methodology involved reviewing literature related to closed-incision negative-pressure therapy in abdominal wall surgery, obtaining utility estimates to calculate quality-adjusted life-year scores for successful surgery and surgery complicated by surgical-site infection, summing costs using Medicare Current Procedural Terminology codes, and creating a decision tree illuminating the most cost-effective dressing strategy. One-way sensitivity analysis was performed to assess the robustness of the results. The aforementioned meta-analysis comparing closed-incision negative-pressure therapy to standard dressings included a subset of five studies assessing abdominal wall surgery in 829 patients (260 closed-incision negative-pressure therapy and 569 standard dressings). Decision tree analysis revealed an estimated savings of $1546.52 and a gain of 0.0024 quality-adjusted life-year with closed-incision negative-pressure therapy compared with standard dressings; therefore, closed-incision negative-pressure therapy is a dominant treatment strategy. One-way sensitivity analysis revealed that closed-incision negative-pressure therapy is a cost-effective option when the surgical-site infection rate is greater than 16.39 percent. The use of closed-incision negative-pressure therapy is cost-saving following closure of abdominal incisions in high-risk patients.
The role of allogenic keratin-derived dressing in wound healing in a mouse model.
Konop, Marek; Sulejczak, Dorota; Czuwara, Joanna; Kosson, Piotr; Misicka, Aleksandra; Lipkowski, Andrzej W; Rudnicka, Lidia
2017-01-01
Keratin is an interesting protein needed for wound healing and tissue recovery. We have recently proposed a new, simple and inexpensive method to obtain fur and hair keratin-derived biomaterials suitable for medical application. The aim of the study was to evaluate the role of the fur keratin-derived protein (FKDP) dressing in the allogenic full-thickness surgical skin wound model. The data obtained using scanning electron microscopy showed that employed processed biomaterial had higher surface porosity compared with control raw material. From the MTS test, it was found keratin biomaterial is not only toxic to the NIH/3T3 cell line (p < 0.05), but also enhances cell proliferation compared with the control. In vivo studies have shown keratin dressings are tissue biocompatible, accelerate wound closure and epithelialization to the statistically significant differences on day 5 (p < 0.05) in comparison to control wounds. Histological examination revealed, that in FKDP-treated wounds the inflammatory response contained predominantly macrophages whilst their morphological untreated variants showed mixed cell infiltrates rich in neutrophils. Predominant macrophages based response creates more favorable environment for healing. In FKDP-dressed wounds the number of microhemorrhages was also significantly decreased (p < 0.05) as compared with undressed wounds. Applied keratin dressing favors reconstruction of a more regular skin structure and assures better cosmetic effect in terms of scar formation and appearance. In conclusion, fur keratin-derived protein dressings significantly accelerated wound healing in the mouse model. Further studies are needed to determine the molecular mechanisms involved in the multilayer wound healing process and to assess the possible use of these dressings for medical purposes. © 2016 by the Wound Healing Society.
Dressed soliton in quantum dusty pair-ion plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterjee, Prasanta; Muniandy, S. V.; Wong, C. S.
Nonlinear propagation of a quantum ion-acoustic dressed soliton is studied in a dusty pair-ion plasma. The Korteweg-de Vries (KdV) equation is derived using reductive perturbation technique. A higher order inhomogeneous differential equation is obtained for the higher order correction. The expression for a dressed soliton is calculated using a renormalization method. The expressions for higher order correction are determined using a series solution technique developed by Chatterjee et al. [Phys. Plasmas 16, 072102 (2009)].
43. Dressing rooms and corridor in basement on west side ...
43. Dressing rooms and corridor in basement on west side of building, looking south. (July 1991) A nearly identical corridor with dressing rooms ran along the east side of the basement, and the two corridors were connected by a short hallway at the north end. The theatre seats seen in hallway in this photo are from Seattle's Orpheum Theatre which was demolished in 1967. - Fox Theater, Seventh Avenue & Olive Way, Seattle, King County, WA
Leclercq, A; Labeille, B; Perrot, J-L; Vercherin, P; Cambazard, F
2016-01-01
Leg ulcers are a common condition. There have been very few studies of combined therapy involving VAC (vacuum-assisted closure) and skin graft. We performed a randomized controlled trial of VAC therapy vs. hydrocolloid dressings over 5 days following autologous grafting on chronic leg ulcers. The primary objective was to assess the difference in success (defined as a reduction in wound area of at least 50% at 1 month) between the two dressing methods. Forty-six patients with ulcers present for over one month were included. Following a 7-day hospitalization period, follow-up was performed for 3 months on an outpatient basis. Our study does not demonstrate a statistically significant difference, with a 45.8% success rate in the VAC group vs. 40.9% in the conventional dressing group (P=0.73). In the venous ulcer group, the success rate was 57.9% for VAC vs. 40% for conventional dressings (P=0.3). The difference in favor of VAC in this group was not statistically significant, most likely due to an insufficient number of patients studied. Our study does not demonstrate superiority of VAC associated with skin graft over conventional dressings. We observed more complications with VAC (40%) than with conventional dressings (23%) (P=0.06). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Preparation of SMART wound dressings based on colloidal microgels and textile fibres
NASA Astrophysics Data System (ADS)
Cornelius, Victoria J.; Majcen, Natasa; Snowden, Martin J.; Mitchell, John C.; Voncina, Bojana
2007-01-01
Wound dressings and other types of wound healing technologies are experiencing fast-paced development and rapid growth. As the population ages, demand will continue to rise for advanced dressings used to treat chronic wounds, such as pressure ulcers, venous stasis ulcers, and diabetic ulcers. Moist wound dressings, which facilitate natural wound healing in a cost-effective manner, will be increasingly important. In commercially available hydrogel / gauze wound dressings the gel swells to adsorb wound excreta and provide an efficient non adhesive particle barrier. An alternative to hydrogels are microgels. Essentially discrete colloidal gel particles, as a result of their very high surface area to volume ratio compared to bulk gels, they have a much faster response to external stimuli such as temperature or pH. In response to either an increase or decrease in solvent quality these porous networks shrink and swell reversibly. When swollen the interstitial regions within the polymer matrix are available for further chemistry; such as the incorporation of small molecules. The reversible shrinking and swelling as a function of external stimuli provides a novel drug release system. As the environmental conditions of a wound change over its lifetime, tending to increase in pH if there is an infection combining these discrete polymeric particles with a substrate such as cotton, results in a smart wound dressing.
Sung, Kun-Yong; Lee, Sang-Yeul
2016-05-01
Neonatal extravasation injuries are often associated with peripheral parenteral nutrition. Several treatment modalities have been developed and used for managing these injuries with variable results. However, there is a lack of consensus regarding the management of neonatal extravasation injuries. The aim of this paper is to introduce a new nonoperative method for the treatment of neonatal extravasation injuries associated with parenteral nutrition. The authors made multiple punctures on the extravasated wound using a No. 11 scalpel blade tip and applying a DuoDERM Extra Thin (ConvaTec Inc, Princeton, NJ) dressing, a hydrocolloid dressing. The dressing was changed every 6 hours on the first day, and dressing changes were continued with decreasing frequency according to the amount of exudate until the wound healed. After the devitalized tissue began to demarcate and autolyse, surgical debridement was gradually performed. Twelve neonatal extravasation injuries, which occurred between November 2010 and June 2014, were evaluated. The mean follow-up duration was 10 months. The average duration of treatment for wound healing was 25 days. All wounds healed without func- tional deficits and conspicuous scars. The authors suggest their new method of using multiple punctures and a hydrocolloid dressing is an easy, effective, and minimally invasive treatment for neonatal extravasation injuries associated with peripheral parenteral nutrition, and it can be used as an alternative treatment option.
Zhao, Xin; Wu, Hao; Guo, Baolin; Dong, Ruonan; Qiu, Yusheng; Ma, Peter X
2017-04-01
Injectable self-healing hydrogel dressing with multifunctional properties including anti-infection, anti-oxidative and conductivity promoting wound healing process will be highly desired in wound healing application and its design is still a challenge. We developed a series of injectable conductive self-healed hydrogels based on quaternized chitosan-g-polyaniline (QCSP) and benzaldehyde group functionalized poly(ethylene glycol)-co-poly(glycerol sebacate) (PEGS-FA) as antibacterial, anti-oxidant and electroactive dressing for cutaneous wound healing. These hydrogels presented good self-healing, electroactivity, free radical scavenging capacity, antibacterial activity, adhesiveness, conductivity, swelling ratio, and biocompatibility. Interestingly, the hydrogel with an optimal crosslinker concentration of 1.5 wt% PEGS-FA showed excellent in vivo blood clotting capacity, and it significantly enhanced in vivo wound healing process in a full-thickness skin defect model than quaternized chitosan/PEGS-FA hydrogel and commercial dressing (Tegaderm™ film) by upregulating the gene expression of growth factors including VEGF, EGF and TGF-β and then promoting granulation tissue thickness and collagen deposition. Taken together, the antibacterial electroactive injectable hydrogel dressing prolonged the lifespan of dressing relying on self-healing ability and significantly promoted the in vivo wound healing process attributed to its multifunctional properties, meaning that they are excellent candidates for full-thickness skin wound healing. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dressed Gain from the Parametrically Amplified Four-Wave Mixing Process in an Atomic Vapor.
Zhang, Zhaoyang; Wen, Feng; Che, Junling; Zhang, Dan; Li, Changbiao; Zhang, Yanpeng; Xiao, Min
2015-10-14
With a forward cone emitting from the strong pump laser in a thermal rubidium atomic vapor, we investigate the non-degenerate parametrically amplified four-wave mixing (PA-FWM) process with dressing effects in a three-level "double-Λ" configuration both theoretically and experimentally. By seeding a weak probe field into the Stokes or anti-Stokes channel of the FWM, the gain processes are generated in the bright twin beams which are called conjugate and probe beams, respectively. However, the strong dressing effect of the pump beam will dramatically affect the gain factors both in the probe and conjugate channels, and can inevitably impose an influence on the quantum effects such as entangled degree and the quantum noise reduction between the two channels. We systematically investigate the intensity evolution of the dressed gain processes by manipulating the atomic density, the Rabi frequency and the frequency detuning. Such dressing effects are also visually evidenced by the observation of Autler-Townes splitting of the gain peaks. The investigation can contribute to the development of quantum information processing and quantum communications.
Mitchell, Michael S; Koen, Clifford M; Darden, Stephen M
2014-01-01
As more and more individuals express themselves with tattoos and body piercings and push the envelope on what is deemed appropriate in the workplace, employers have an increased need for creation and enforcement of reasonable dress codes and appearance policies. As with any employment policy or practice, an appearance policy must be implemented and enforced without regard to an individual's race, color, gender, national origin, religion, disability, age, or other protected status. A policy governing dress and appearance based on the business needs of an employer that is applied fairly and consistently and does not have a disproportionate effect on any protected class will generally be upheld if challenged in court. By examining some of the more common legal challenges to dress codes and how courts have resolved the disputes, health care managers can avoid many potential problems. This article, the second part of a 3-part examination of dress codes and appearance policies, focuses on the issue of gender under the Civil Rights Act of 1964. Pertinent court cases that provide guidance for employers are addressed.
Franchini, D; Cavaliere, L; Valastro, C; Carnevali, F; van der Esch, A; Lai, O; Di Bello, A
2016-05-03
The loggerhead Caretta caretta is the most common sea turtle in the Mediterranean. Currently, sea turtles are considered endangered, mainly due to the impact of human activities. Among traumatic lesions, those involving the skull, if complicated by brain exposure, are often life-threatening. In these cases, death could be the outcome of direct trauma of the cerebral tissue or of secondary meningoencephalitis. This uncontrolled study aims to evaluate the use of a plant-derived dressing (1 Primary Wound Dressing®) in 3 sea turtles with severe lesions of the skull exposing the brain. Following surgical curettage, the treatment protocol involved exclusive use of the plant-derived dressing applied on the wound surface as the primary dressing, daily for the first month and then every other day until the end of treatment. The wound and peri-wound skin were covered with a simple secondary dressing without any active compound (non-woven gauze with petroleum jelly). Data presented herein show an excellent healing process in all 3 cases and no side effects due to contact of the medication with the cerebral tissue.
NASA Astrophysics Data System (ADS)
Sawitri, Sicilia
2018-03-01
The aims of the research were: (1) To know the students' achievement in Dress Making Teaching by implementing Integrated Entrepreneur Material in Vocational High School, (2) The level of increasing of students' achievement in Dress Making Teaching by integrating Entrepreneurship Material in Vocational High School. By using experimental method this research was conducted in Magelang Vocational High School and applied pre-test post-test design. The samples in this research was XI grade of Fashion Technology Study Program. Observation sheet and documentation were used in this research as instruments. Data analyzed by using descriptive analyze and gain score. The result, there were: (1) students' achievement in Dress Making Teaching was high 88.6 and (2) the increasing of students' achievement was 0.61 it was medium category. The suggestion were: Integrated Entrepreneurship material can be applied in another subject matter, such as Men Wear, Tailoring, Children Wear, and The students who want to be a good entrepreneur, have to drill their skill in making dresses, and know about excellent service to the clients, marketing and make clients satisfaction.
Dressed Gain from the Parametrically Amplified Four-Wave Mixing Process in an Atomic Vapor
NASA Astrophysics Data System (ADS)
Zhang, Zhaoyang; Wen, Feng; Che, Junling; Zhang, Dan; Li, Changbiao; Zhang, Yanpeng; Xiao, Min
2015-10-01
With a forward cone emitting from the strong pump laser in a thermal rubidium atomic vapor, we investigate the non-degenerate parametrically amplified four-wave mixing (PA-FWM) process with dressing effects in a three-level “double-Λ” configuration both theoretically and experimentally. By seeding a weak probe field into the Stokes or anti-Stokes channel of the FWM, the gain processes are generated in the bright twin beams which are called conjugate and probe beams, respectively. However, the strong dressing effect of the pump beam will dramatically affect the gain factors both in the probe and conjugate channels, and can inevitably impose an influence on the quantum effects such as entangled degree and the quantum noise reduction between the two channels. We systematically investigate the intensity evolution of the dressed gain processes by manipulating the atomic density, the Rabi frequency and the frequency detuning. Such dressing effects are also visually evidenced by the observation of Autler-Townes splitting of the gain peaks. The investigation can contribute to the development of quantum information processing and quantum communications.
The role of one-shot learning in #TheDress.
Drissi Daoudi, Leila; Doerig, Adrien; Parkosadze, Khatuna; Kunchulia, Marina; Herzog, Michael H
2017-03-01
#TheDress is remarkable in two aspects. First, there is a bimodal split of the population in the perception of the dress's colors (white/gold vs. black/blue). Second, whereas interobserver variance is high, intra-observer variance is low, i.e., the percept rarely switches in a given individual. There are two plausible routes of explanations: either one-shot learning during the first presentation of the image splits observers into two different, stable populations, or the differences are caused by stable traits of observers, such as different visual systems. Here, we hid large parts of the image by white occluders. The majority of naïve participants perceived the dress as black and blue. With black occluders, the majority of observers perceived the dress as white and gold. The percept did not change when we subsequently presented the full image, arguing for a crucial role of one-shot learning. Next, we investigated whether the first fixation determines the perceived color in naïve observers. We found no such effect. It remains thus a puzzling question where the source of variability in the different percepts comes from.
Shahzad, Muhammad Naveed; Ahmed, Naheed
2013-02-01
To assess the efficacy of Aloe Vera gel compared with 1% silver sulfadiazine cream as a burn dressing for the treatment of superficial and partial thickness burns. This Interventional Comparative study was carried out at the Burn unit and Plastic surgery department, Nishtar Hospital Multan, Pakistan from July 2008 to December 2010. A total of 50 patients with superficial and partial thickness burns were divided into two equal groups randomly by consecutive sampling method, one group was dressed with Aloe Vera gel while the other was treated with 1% silversulphadiazine cream, and the results regarding duration of wound epithelialization, pain relief and cost of treatment were compared. In patients treated with Aloe Vera gel, healing of burn wounds were remarkably early than those patients treated with 1% silver sulfadiazine. All the patients of Aloe Vera group were relieved of pain earlier than those patients who were treated with SSD. Thermal burns patients dressed with Aloe Vera gel showed advantage compared to those dressed with SSD regarding early wound epithelialization, earlier pain relief and cost-effectiveness.
Honey in wound care: effects, clinical application and patient benefit.
Lay-flurrie, Karen
The use of honey in wound management has enjoyed a resurgence. This is largely due to the growing clinical problem of antibiotic-resistant bacteria and the combined difficulties for the practitioner in managing chronic wound types, such as burns, leg ulcers or surgical wounds, that may become infected, for example, with methicillin-resistant Staphylococcus aureus or Pseudomonas. The associated costs of treating such wounds are escalating as a result. While the use of honey as a wound dressing has been recognized, at least since Egyptian times circa 2000 BC, it is only more recently, due to the development and licensing of modern honey wound dressings, that such dressings have become more widely available and used in wound management. This article focuses on the use of honey in the treatment of infected wounds and burns. It will examine the effects of honey at the wound bed and its clinical applications, along with the current dressings available. Also discussed are the practical considerations, if, like any wound dressing, honey is to be used safely, appropriately and for the benefit of the patient.
Dressing effects on the occurrence scattering time retardation and advance in a dusty plasma
NASA Astrophysics Data System (ADS)
Lee, Myoung-Jae; Jung, Young-Dae; Hanyang Plasma Team
2017-10-01
The dressing effects on the occurrence scattering time for the dust-dust interaction are investigated in a complex plasma. The first-order eikonal analysis is applied to obtain the scattering amplitude and the occurrence scattering time for the dust-dust interaction. The result shows that dressing effect enhances the retardation phenomena of the occurrence scattering time in the forward scattering domain. It is shown that the oscillatory behavior of the scaled occurrence scattering time is getting more significant with an increase of the Debye length. It is also found that the retardation domain of the occurrence scattering time increases with a decrease of the Debye length. The variation of the occurrence scattering time retardation and advance due to the dressing effect is also discussed.
Dupouey, Julien; Wiramus, Sandrine; Albanese, Jacques; Guilhaumou, Romain; Blin, Olivier
2016-10-01
Severe burned patients present high risk of skins infections, frequently due to Pseudomonas aeruginosa. Impregnated dressings with amikacin or colistin could be a good alternative to obtain effective concentration directly at the infected site. Therapeutic drug monitoring for these antibiotics is currently recommended after an intravenous administration to obtain effective and non-toxic plasmatic concentrations. However, data are lacking about systemic exposition and risk of toxicity after an administration with impregnated dressings. We report the case of a severe burned patient with cutaneous infection treated with amikacin and colistin impregnated dressings, for which plasmatic pharmacokinetic profiles were performed. Copyright © 2016 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Xu; Chen, Ye-Hong; Shi, Zhi-Cheng; Shan, Wu-Jiang; Song, Jie; Xia, Yan
2017-12-01
Combining the advantages of the dressed states and superconducting quantum interference device (SQUID) qubits, we propose an efficient scheme to generate Greenberger-Horne-Zeilinger (GHZ) states for three SQUID qubits. Firstly, we elaborate how to generate GHZ states of three SQUID qubits by choosing a set of dressed states suitably. Then, we compare the scheme by using dressed states with that via the adiabatic passage. Lastly, the influence of various decoherence factors, such as cavity decay, spontaneous emission and dephasing, is analyzed numerically. All of the results show that the GHZ state can be obtained fast and with high fidelity and that the present scheme is robust against the cavity decay and spontaneous emission. In addition, our scheme is more stable against the dephasing than the adiabatic scheme.
Febuxostat hypersensitivity: another cause of DRESS syndrome in chronic kidney disease?
Paschou, E; Gavriilaki, E; Papaioannou, G; Tsompanakou, A; Kalaitzoglou, A; Sabanis, N
2016-11-01
Febuxostat is a xanthine oxidase inhibitor that during the last years has successfully replaced allopurinol treatment in patients with chronic kidney disease (CKD) and hyperuricemia. Several adverse events have been observed during therapy with febuxostat. DRESS (Drug Reaction with Eosinophilia and Systemic Symptoms) syndrome induced by febuxostat has been poorly described, mainly in patient with CKD who previously developed allopurinol hypersensitivity syndrome. DRESS syndrome is characterized by manifold cutaneous reactions and systemic disorders with potential devastating consequences. The underlying pathogenetic mechanisms remain unidentified, though immune responses are often complicated. P-i concept can partially explain the phenomenon. The role of renal insufficiency appears to be crucial and further investigation is required. The present article describes the case of a CKD patient that developed febuxostat-related DRESS syndrome.
Recent advances on antimicrobial wound dressing: A review.
Simões, Déborah; Miguel, Sónia P; Ribeiro, Maximiano P; Coutinho, Paula; Mendonça, António G; Correia, Ilídio J
2018-06-01
Skin and soft tissue infections (SSTIs) have high rates of morbidity and mortality associated. Despite the successful treatment of some SSTIs, those affecting the subcutaneous tissue, fascia, or muscle delay the healing process and can lead to life-threatening conditions. Therefore, more effective treatments are required to deal with such pathological situations. Recently, wound dressings loaded with antimicrobial agents emerged as viable options to reduce wound bacterial colonization and infection, in order to improve the healing process. In this review, an overview of the most prominent antibacterial agents incorporated in wound dressings along with their mode of action is provided. Furthermore, the recent advances in the therapeutic approaches used in the clinic and some future perspectives regarding antibacterial wound dressings are also discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
Jacobson, Caroline; Williams, Andrew; Yang, Rongchang; Ryan, Una; Carmichael, Ian; Campbell, Angus J; Gardner, Graham E
2016-09-15
Associations between intensity and frequency of Cryptosporidium and Giardia shedding with growth, carcase weight and dressing% were investigated using a longitudinal study of 1182 lambs on eight Australian farms. Live weight was recorded and faecal samples were collected on three sampling occasions; weaning (approximately 12 weeks of age), post-weaning (approximately 19 weeks) and pre-slaughter (approximately 29 weeks). Hot standard carcase weight (HSCW) and dressing% were measured at slaughter. Faecal samples were screened for presence and concentration of Cryptosporidium, Giardia and Haemonchus oocysts using a quantitative PCR. Trichostrongylid eggs were quantified with modified McMaster faecal worm egg count (WEC). Protozoan shedding intensity was categorised as high (above median oocyst concentration in positive sheep), low (below median oocyst concentration in positive sheep) or not detected. Shedding was also categorised for shedding type (no shedding, single Giardia infection, single Cryptosporidium infection, concurrent Giardia and Cryptosporidium infection) and lambs were categorised for frequency of shedding (shedding identified on 0, 1, 2 or 3 occasions). Associations of parasite shedding intensity category, shedding type, shedding frequency, WEC and Haemonchus status (positive or negative) with lamb production were assessed using general linear models (HSCW and dressing%) and linear mixed effects models (live weight). High Cryptosporidium parvum shedding was associated with lower live weight, ranging 2.31-4.52kg over the 3 sampling occasions. Cryptosporidium parvum shedding was associated with less HSCW in high (3.22kg less) and low (3.22kg less) shedding lambs post-weaning, and high (2.21kg less) and low (2.60kg less) shedding lambs pre-slaughter as well as lower dressing% (2.7% lower in high shedding lambs post-weaning). Cryptosporidium (all species) shedding pre-slaughter was associated with reduced dressing% in both high (1.25% lower) and low (1.21% lower) shedding lambs. Giardia shedding pre-slaughter was associated with 0.59kg less HSCW in high shedding lambs. Increased frequency of C. parvum and Giardia shedding in a specific animal (repeated detection) were associated with reduced HSCW and dressing%. Concurrent Giardia and Cryptosporidium shedding pre-slaughter was associated with reduced dressing%. No statistically significant main effects for either WEC (P>0.05) or Haemonchus status (P>0.05) were identified for any of the sheep meat productivity measures (live weight, HSCW and dressing%). The findings suggest naturally acquired Cryptosporidium and Giardia infections in grazing sheep are associated with depressed growth, carcase weight and dressing efficiency beyond the neonatal period in sheep representing a range of genetic backgrounds and different sheep production environments. Copyright © 2016 Elsevier B.V. All rights reserved.
Retrenchment: General Russell E. Dougherty and the Strategic Air Command During the Age of Detente
2014-06-01
could reschedule for the next day. Dougherty noted he was unable to stay in Washington for an 38...their aid. The wife turned out to be a nurse and she tore strips from the dress she was wearing to stop Dougherty’s bleeding. Weir landed in a...bought a new dress and mailed it to the nurse who ruined her own dress in her efforts to aid him and his friend.94 Dougherty still had one arm in a
Effect of magnon-phonon interactions on magnon squeezed states in ferromagnets
NASA Astrophysics Data System (ADS)
Mikhail, I. F. I.; Ismail, I. M. M.; Ameen, M.
2018-02-01
The squeezed states of dressed magnons in ferromagnets have been investigated. No effective Debye cutoff frequency has been assumed unlike what has been done hitherto. Instead, the results have been expressed throughout in terms of the reduced temperature. The effect of dressed magnon-phonon interactions on the formulation of these states has been studied. It has been shown that the magnon-phonon interactions play a significant role in determining the squeeze factor and the variation of the dressed magnon effective mass with temperature.
Painful dressing changes for chronic wounds: assessment and management.
Solowiej, Kazia; Upton, Dominic
Wound pain can arise from the wound itself, continuing wound treatment and anticipatory pain, which occurs in some patients as a consequence of negative experiences of care. Specifically, pain caused by the removal and application of dressings has been identified as a major contributor to wound pain, from both patient and health professional perspectives. This article reviews literature on the impact of pain at dressing change, and provides practical suggestions for assessment and management of pain during wound care.
2014-04-01
The MSD is comprised of a syringe applicator filled with compressed chitosan coated sponges which are delivered into the wound at the site of the...transmitted effectively to the deep subclavian vessels to stop hemorrhage. As a result of their non-compressible nature and paucity of effective field...followed by three minutes of compression to the packed dressing. The mini- sponge dressing (MSD) is a novel product that utilizes compressed, chitosan
9. View to west of Tropic Dressing Room (typical). ...
9. View to west of Tropic Dressing Room (typical). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA
Silver-containing foam dressings with Safetac: a review of the scientific and clinical data.
Davies, Phil; McCarty, Sara; Hamberg, Kristina
2017-06-01
Background Topical antimicrobials, such as silver dressings, are progressively being used alongside systemic antibiotics to provide adjunctive, antimicrobial therapy to wounds that are clinically infected or at risk of infection. To help improve wound management, dressings that use Safetac soft silicone technology in combination with a silver-impregnated foam dressing material were developed by Mölnlycke Health Care (Gothenburg, Sweden). The range comprises Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag. Aims A literature review was undertaken to identify and summarise clinical data from the entire evidence hierarchy, as well as data from in vitro tests, which support the use of silver-containing foam dressings with Safetac. Method The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier BV, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (oral, e-poster and poster) of relevance to the review. Results In vitro test results showed that the silver-containing foam dressings with Safetac have both rapid and sustained activity against a range of wound pathogens, reducing planktonic and established biofilm cultures, and preventing biofilm formation. In numerous clinical studies, silvercontaining foam dressings with Safetac were used to manage wound bioburden effectively and resolve signs of localised infection in both acute wounds (such as surgical, traumatic and burn injuries) and chronic wounds (such as leg ulcers, pressure ulcers (PUs), diabetic foot ulcers (DFUs), and cancerous wounds). Studies reported that silver-containing foam dressings with Safetac are easy to use, provide an optimal environment for wound healing, and are associated with atraumatic and virtually painfree removal. As well as being clinically effective, they are reported to be cost-effective when used on wounds that require topical antimicrobial therapy. Conclusion The findings of both scientific and clinical studies clearly indicate that clinical, patient-related and economic benefits are associated with the use of Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag with Safetac in the treatment of wounds where antimicrobial activity is needed to help manage bioburden.
Pregnancy Complications: Salmonellosis
... including homemade mayonnaise, hollandaise sauce, Caesar salad dressing, cookie dough, frostings and homemade ice cream. Unpasteurized milk, milk ... including homemade mayonnaise, hollandaise sauce, Caesar salad dressing, cookie dough, frostings and homemade ice cream. Unpasteurized milk, milk ...
Satake, Toshihiko; Muto, Mayu; Nagashima, Yu; Haga, Shoko; Homma, Yuki; Nakasone, Reiko; Kadokura, Marina; Kou, Seiko; Fujimoto, Hiroshi; Maegawa, Jiro
2018-04-01
We describe a new wound management technique using a soft dressing material to stabilize the areola skin graft and protect the nipple after nipple-areola reconstruction at the final stage of breast reconstruction. We introduced a center-fenestrated multilayered hydrocellular polyurethane foam dressing material that provides adequate pressure and retains a moist environment for a smooth skin graft "take." Moreover, the reconstructed nipple can be monitored at any time through the fenestrated window for adequate blood circulation. Altogether, this simple and inexpensive wound dressing technique improves the clinical outcome. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Stokes, Tracey H; Follmar, Keith E; Silverstein, Ari D; Weizer, Alon Z; Donatucci, Craig F; Anderson, Everett E; Erdmann, Detlev
2006-06-01
From 1988 to 2005, 8 men who presented with penoscrotal elephantiasis underwent penile shaft degloving and reduction scrotoplasty, followed by transplantation of a split-thickness skin graft (STSG) to the penile shaft. The etiology of elephantiasis in these patients included self-injection of viscous fluid and postsurgical obstructive lymphedema. In the 6 most recent cases, negative-pressure dressings were applied over the STSG to promote graft take, and STSG take rate was 100%. The results of our series corroborate those of a previous report, which showed circumferential negative-pressure dressings to be safe and efficacious in bolstering STSGs to the penile shaft. Furthermore, these results suggest that the use of negative-pressure dressings may improve graft take in this patient population.
DRESS syndrome with thrombotic microangiopathy revealing a Noonan syndrome: Case report.
Bobot, Mickaël; Coen, Matteo; Simon, Clémentine; Daniel, Laurent; Habib, Gilbert; Serratrice, Jacques
2018-04-01
The life-threatening drug rash with eosinophilia and systemic symptoms (DRESS) syndrome occurs most commonly after exposure to drugs, clinical features mimic those found with other serious systemic disorders. It is rarely associated with thrombotic microangiopathy. We describe the unique case of a 44-year-old man who simultaneously experienced DRESS syndrome with thrombotic microangiopathy (TMA) after a 5 days treatment with fluindione. Clinical evaluation leads to the discovery of an underlying lymphangiomatosis, due to a Noonan syndrome. The anticoagulant was withdrawn, and corticosteroids (1 mg/kg/day) and acenocoumarol were started. Clinical improvement ensued. At follow-up the patient is well. The association of DRESS with TMA is a rare condition; we believe that the presence of the underlying Noonan syndrome could have been the trigger. Moreover, we speculate about the potential interrelations between these entities.
Efficacy of chitosan dressing on endoscopic sinus surgery: a systematic review and meta-analysis.
Zhou, Jing-Chun; Zhang, Jing-Jing; Zhang, Wei; Ke, Zhao-Yang; Zhang, Bo
2017-09-01
Chitosan dressing might be promising to promote the recovery following endoscopic sinus surgery (ESS). However, the results remain controversial. We conducted a systematic review and meta-analysis to explore the influence of chitosan dressing on ESS. PubMed, EMbase, Web of science, EBSCO, and Cochrane library databases were systematically searched. Randomized controlled trials (RCTs) assessing the effect of chitosan dressing on endoscopic sinus surgery were included. Two investigators independently searched articles, extracted data, and assessed the quality of included studies. The primary outcomes were synechia and hemostasis. Meta-analysis was performed using random-effect model. Four RCTs involving 268 patients were included in the meta-analysis. Overall following ESS, compared with control intervention, chitosan dressing significantly reduced synechia (RR = 0.25; 95% CI 0.13-0.49; P < 0.0001) and promoted hemostasis (RR = 1.70; 95% CI 1.37-2.11; P < 0.00001), but showed no impact on granulations (RR = 1.18; 95% CI 0.72-1.95; P = 0.52), mucosal edema (RR = 0.88; 95% CI 0.60-1.29; P = 0.51), crusting (RR = 0.85; 95% CI 0.48-1.53; P = 0.60), and infection (RR = 0.88; 95% CI 0.51-1.52; P = 0.64). Compared to control intervention, chitosan dressing could significantly decrease edema and improve hemostasis, but had no effect on granulations, mucosal edema, crusting and infection.
Using transparent polyurethane film and hydrocolloid dressings to prevent pressure ulcers.
Dutra, R A A; Salomé, G M; Alves, J R; Pereira, V O S; Miranda, F D; Vallim, V B; de Brito, M J A; Ferreira, L M
2015-06-01
To compare the performance and effectiveness of a hydrocolloid dressing (HD) and a transparent polyurethane film (PF) in preventing pressure ulcer (PU) development. The study was conducted in the intensive care unit, coronary care unit and medical clinic of the Holy House of Mercy of Passos, Brazil. Data were collected 48 hours after admission and during hospitalisation. The Braden scale was used for PU risk assessment. Consecutive eligible patients without PUs were randomly assigned by lottery to the two groups, either the HD or PF group. Of the 160 eligible patients, significant between-group differences were found in the mean total number of dressing changes (HD, 6.09±1.655 changes; PF, 5.59±2.036 changes; p=0.010), and mean number of dressing changes in the sacral region (HD, 2.50±0.871; PF, 2.05±0.825; p=0.001), with the PF group requiring significantly fewer changes than the HD group. The most common reasons for changing dressings in both groups were moisture (PF 51.1%; HD 47.9%) and shear (HD 43%; PF 38.9%), with a significant difference in shear between groups. The incidence of PUs was significantly lower (p=0.038) in the PF group (8.7%) compared with that in the HD group (15%). The results suggest that the transparent polyurethane film had a better performance and was more effective than the hydrocolloid dressing in preventing PU development.
Do Prophylactic Foam Dressings Reduce Heel Pressure Injuries?
Ramundo, Janet; Pike, Catlin; Pittman, Joyce
The purpose of this evidence-based report card is to examine the evidence and provide recommendations related to the effectiveness of prophylactic foam dressings in reducing heel pressure injuries. Do prophylactic foam dressings applied to the heel reduce heel pressure injuries for patients in the acute care setting? A search of the literature was performed by a trained university librarian that resulted in 56 articles that examined pressure injury, prevention, and prophylactic dressings. A systematic approach was used to review titles, abstracts, and text, yielding 13 studies that met inclusion criteria. Strength of the evidence was rated based on the methodology from Essential Evidence Plus: Levels of Evidence and Oxford Center for Evidence-Based Medicine. Thirteen studies were identified that met inclusion criteria; 1 was a randomized controlled trial, 2 were systematic reviews, 3 quasi-experimental cohort studies, 1 quality improvement study, 1 case series, 1 scoping review, 1 consensus panel, and 3 bench studies. All of the studies identified suggest that the use of prophylactic foam dressings reduces the development of pressure injuries on the heel when used in conjunction with a pressure injury prevention program. The strength of the evidence for the identified studies was level 1 (4 level A, 4 level B, and 5 level C). The use of prophylactic multilayer foam dressings applied to the heels, in conjunction with an evidence-based pressure injury prevention program, is recommended for prevention of pressure injuries on the heel (SORT level 1).
Wasiak, Jason; Mahar, Patrick D; Paul, Eldho; Menezes, Hana; Spinks, Anneliese B; Cleland, Heather
2014-02-01
Pain is a common and significant feature of burn injury. The use of intravenous opioids forms the mainstay of procedural burn pain management, but in an outpatient setting, the demand for novel agents that do not require parenteral access, are easy to administer and have a rapid onset are urgently needed. One such agent is the inhaled anaesthetic agent, methoxyflurane (MF). The aim of this study was to conduct a pilot investigation into the clinical effectiveness of MF inhaler on pain and anxiety scores in patients undergoing burn wound care procedures in an outpatient setting. A prospective case series involved recruiting patients undergoing a burn wound care procedure in an ambulatory burn care setting. Pain and anxiety were assessed using numerical rating scales. Overall, median numerical pain rating score was significantly higher post-dressing [pre-dressing: 2; interquartile range (IQR): 1-3 versus post-dressing: 3; IQR 1·5-4; P = 0·01], whereas median numerical anxiety score significantly reduced following the dressing (pre-dressing: 5; IQR 4-7 versus post-dressing: 2; IQR 1-2; P < 0·001). Our study suggests that there is a role for MF in the pain management armamentarium in those undergoing burn care procedures in the ambulatory care setting. However, there is an urgent need for larger case series and randomised controlled trials to determine its overall clinical effectiveness. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Rapid hemostatic and mild polyurethane-urea foam wound dressing for promoting wound healing.
Liu, Xiangyu; Niu, Yuqing; Chen, Kevin C; Chen, Shiguo
2017-02-01
A novel rapid hemostatic and mild polyurethane-urea foam (PUUF) wound dressing was prepared by the particle leaching method and vacuum freeze-drying method using 4, 4-Methylenebis(cyclohexyl isocyanate), 4,4-diaminodicyclohexylmethane and poly (ethylene glycol) as raw materials. And X-ray diffraction (XRD), tensile test, differential scanning calorimetry (DSC) and thermogravimetry (TG) were used to its crystallinity, stress and strain behavior, and thermal properties, respectively. Platelet adhesion, fibrinogen adhesion and blood clotting were performed to evaluate its hemostatic effect. And H&E staining and Masson Trichrome staining were used to its wound healing efficacy. The results revealed the pore size of PUUF is 50-130μm, and its porosity is 71.01%. Porous PUUF exhibited good water uptake that was benefit to adsorb abundant wound exudates to build a regional moist environment beneficial for wound healing. The PUUF wound dressing exhibit better blood coagulation effect than commercial polyurethane dressing (CaduMedi). Though both PUUF and CaduMedi facilitated wound healing generating full re-epithelialization within 13days, PUUF was milder and lead to more slight inflammatory response than CaduMedi. In addition, PUUF wound dressing exhibited lower cytotoxicity than CaduMedi against NIH3T3 cells. Overall, porous PUUF represents a novel mild wound dressing with excellent water uptake, hemostatic effect and low toxicity, and it can promote wound healing and enhance re-epithelialization. Copyright © 2016 Elsevier B.V. All rights reserved.
Neutron stars in screened modified gravity: Chameleon versus dilaton
NASA Astrophysics Data System (ADS)
Brax, Philippe; Davis, Anne-Christine; Jha, Rahul
2017-04-01
We consider the scalar field profile around relativistic compact objects such as neutron stars for a range of modified gravity models with screening mechanisms of the chameleon and Damour-Polyakov types. We focus primarily on inverse power law chameleons and the environmentally dependent dilaton as examples of both mechanisms. We discuss the modified Tolman-Oppenheimer-Volkoff equation and then implement a relaxation algorithm to solve for the scalar profiles numerically. We find that chameleons and dilatons behave in a similar manner and that there is a large degeneracy between the modified gravity parameters and the neutron star equation of state. This is exemplified by the modifications to the mass-radius relationship for a variety of model parameters.
Mepilex Ag: an antimicrobial, absorbent foam dressing with Safetac technology.
Barrett, Simon
This article examines the role of a unique dressing-Mepilex Ag--that incorporates the rapid and sustained antimicrobial action of ionic silver with the benefits of Safetac soft silicone adhesive technology. The combined attributes of each component of this dressing allow both the control of pain and infection to be achieved simultaneously. This dual approach to the management of wounds is of significance since the evidence suggests that wound infection and the release of pro-inflammatory modulators result in both local pain and delayed healing. In this respect the control and treatment of pain is as important as the treatment of infection itself. A review of the clinical evidence relating to Safetac technology clearly demonstrates that it can be used to prevent dressing-related trauma, minimize pain at dressing change, and control exudate when used on a wide range of wound types and skin injuries. In combination with silver, this technology has been shown in in-vitro studies to have an almost instant and sustainable antimicrobial effect on a broad range of pathogens associated with delayed healing. Finally, in small clinical and case studies, Mepilex Ag has been shown to control wound bioburden and improve healing rates.
Yao, Chun-Hsu; Lee, Chia-Yu; Huang, Chiung-Hua; Chen, Yueh-Sheng; Chen, Kuo-Yu
2017-10-01
A bilayer membrane (GKU) with a commercial polyurethane wound dressing as an outer layer and electrospun gelatin/keratin nanofibrous mat as an inner layer was fabricated as a novel wound dressing. Scanning electron micrographs showed that gelatin/keratin nanofibers had a uniform morphology and bead-free structure with average fiber diameter of 160.4nm. 3-(4,5-Dimethylthiazolyl)-2,5-diphenyltetrazolium bromide assay using L929 fibroblast cells indicated that the residues released from the gelatin/keratin composite nanofibrous mat accelerated cell proliferation. Cell attachment experiments revealed that adhered cells spread better and migrated deeper into the gelatin/keratin nanofibrous mat than that into the gelatin nanofibrous mat. In animal studies, compared with the bilayer membrane without keratin, gauze and commercial wound dressing, Comfeel®, GKU membrane gave much more number of blood vessels and a greater reduction in wound area at 4days, and better wound repair at 14days with a thicker epidermis and larger number of newly formed hair follicles. GKU membrane, thus, could be a good candidate for wound dressing applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Assessment of Chicken-Egg Membrane as a Dressing for Wound Healing.
Guarderas, Fernando; Leavell, Yaowaree; Sengupta, Trisha; Zhukova, Mariya; Megraw, Timothy L
2016-03-01
To examine the efficacy of the folk remedy of chicken-egg membrane dressing on wound healing. Full-thickness excisional wounds were created on 14 male Sprague-Dawley rats in 2 separate trials. Each animal received 2 wounds on the upper back. One wound was untreated, and the other was dressed with chicken-egg membrane to assess its impact on wound healing. Half of the rats received egg membrane treatment on the inferior wound, whereas the other half received egg membrane treatment on the superior wound. Membrane replacement, wound debridement, and imaging were done on days 5, 8, and 10 and then imaging continued on days 12, 14, 16, 18, and 20 of the experiment. Healing rate was measured based on the wound area over the 20 days of the experiment. The wounds dressed with chicken-egg membrane had a significantly (P < .01) faster rate of healing compared with the control at the early stages of healing between days 0 and 5. This group healed 21% faster during this early phase, compared with the control group. Overall, however, wound healing rates were indistinguishable from days 5 to 20. Chicken-egg membrane dressing significantly improves healing of cutaneous wounds in the early stages of wound healing.
Gizaw, Mulugeta; Thompson, Jeffrey; Faglie, Addison; Lee, Shih-Yu; Neuenschwander, Pierre; Chou, Shih-Feng
2018-01-01
Wound healing is a complex tissue regeneration process that promotes the growth of new tissue to provide the body with the necessary barrier from the outside environment. In the class of non-healing wounds, diabetic wounds, and ulcers, dressing materials that are available clinically (e.g., gels and creams) have demonstrated only a slow improvement with current available technologies. Among all available current technologies, electrospun fibers exhibit several characteristics that may provide novel replacement dressing materials for the above-mentioned wounds. Therefore, in this review, we focus on recent achievements in electrospun drug-eluting fibers for wound healing applications. In particular, we review drug release, including small molecule drugs, proteins and peptides, and gene vectors from electrospun fibers with respect to wound healing. Furthermore, we provide an overview on multifunctional dressing materials based on electrospun fibers, including those that are capable of achieving wound debridement and wound healing simultaneously as well as multi-drugs loading/types suitable for various stages of the healing process. Our review provides important and sufficient information to inform the field in development of fiber-based dressing materials for clinical treatment of non-healing wounds. PMID:29382065
Zhao, Dong; Yan, Ting-mei; Qiao, Jun; Yang, Lin-zhang; Tang, Fang; Song, Yun-fei
2015-06-01
This study focused on the nitrogen loss via runoff, change of nitrogen in different forms in surface water in paddy field, and grain yield, through further reduction of nitrogen fertilizer application rate under green manuring without basal dressing. Results showed that with 150 kg · hm(-2) inorganic N fertilizer input after return of green manure to soil, no basal dressing could not only sharply reduce N concentration in surface water and decrease 17.2% of N loss, but also increase 2.8% of grain yield in comparison with basal dressing. It was a worthwhile farming method that inorganic nitrogen fertilizer was not used for basal dressing but for topdressing after return of green ma- nure to soil in Taihu Area. However, the grain yield would decrease if the rate of topdressing nitro- gen was excessively reduced or increased. After all, it was feasible to realize harmonization of grain yield and environmental benefits in Taihu Area, with 133 kg · hm(-2) inorganic N fertilizer input after return of green manure to soil as well as no application of basal dressing, which could greatly reduce N fertilizer input and N loss as well as ensure rice yield.
Pre-inflationary universe in loop quantum cosmology
NASA Astrophysics Data System (ADS)
Zhu, Tao; Wang, Anzhong; Cleaver, Gerald; Kirsten, Klaus; Sheng, Qin
2017-10-01
The evolutions of the flat Friedmann-Lemaître-Robertson-Walker universe and its linear perturbations are studied systematically in the dressed metric approach of loop quantum cosmology. When it is dominated by the kinetic energy of the inflaton at the quantum bounce, the evolution of the background can be divided into three different phases prior to the preheating: bouncing, transition and slow-roll inflation. During the bouncing phase, the evolution is independent of not only the initial conditions, but also the inflationary potentials. In particular, the expansion factor can be well described by the same exact solution in all the cases considered. In contrast, in the potential-dominated case such a universality is lost. It is because of this universality that the linear perturbations are also independent of the inflationary models and obtained exactly. During the transition phase, the evolutions of the background and its linear perturbations are found explicitly, and then matched to the ones given in the other two phases. Hence, once the initial conditions are imposed, the linear scalar and tensor perturbations will be uniquely determined. Considering two different sets of initial conditions, one imposed during the contracting phase and the other at the bounce, we calculate the Bogoliubov coefficients and find that the two sets yield the same results and all lead to particle creations at the onset of the inflation. Due to the preinflationary dynamics, the scalar and tensor power spectra become scale dependent. By comparing our results with the Planck 2015 data, we find constraints on the total number of e -folds since the bounce, in order to be consistent with current observations.
Nonperturbative study of the four gluon vertex
NASA Astrophysics Data System (ADS)
Binosi, D.; Ibañez, D.; Papavassiliou, J.
2014-09-01
In this paper we study the nonperturbative structure of the SU(3) four-gluon vertex in the Landau gauge, concentrating on contributions quadratic in the metric. We employ an approximation scheme where "one-loop" diagrams are computed using fully dressed gluon and ghost propagators, and tree-level vertices. When a suitable kinematical configuration depending on a single momentum scale p is chosen, only two structures emerge: the tree-level four-gluon vertex, and a tensor orthogonal to it. A detailed numerical analysis reveals that the form factor associated with this latter tensor displays a change of sign (zero-crossing) in the deep infrared, and finally diverges logarithmically. The origin of this characteristic behavior is proven to be entirely due to the masslessness of the ghost propagators forming the corresponding ghost-loop diagram, in close analogy to a similar effect established for the three-gluon vertex. However, in the case at hand, and under the approximations employed, this particular divergence does not affect the form factor proportional to the tree-level tensor, which remains finite in the entire range of momenta, and deviates moderately from its naive tree-level value. It turns out that the kinematic configuration chosen is ideal for carrying out lattice simulations, because it eliminates from the connected Green's function all one-particle reducible contributions, projecting out the genuine one-particle irreducible vertex. Motivated by this possibility, we discuss in detail how a hypothetical lattice measurement of this quantity would compare to the results presented here, and the potential interference from an additional tensorial structure, allowed by Bose symmetry, but not encountered within our scheme.
Protect Yourself and Your Baby from Dengue
... the directions on the product » Dress in loose cotton clothing that covers your arms and legs Protect ... months of age • Dress your baby in loose cotton clothing that covers arms and legs How to ...
Nanomaterials from bacterial cellulose for antimicrobial wound dressing
NASA Astrophysics Data System (ADS)
Liyaskina, E.; Revin, V.; Paramonova, E.; Nazarkina, M.; Pestov, N.; Revina, N.; Kolesnikova, S.
2017-01-01
Bacterial nanocellulose (BNC) is widely used in biomedical applications. BNC has attracted increasing attention as a novel wound dressing material, but it has no antimicrobial activity. To get over this problem in the present study the BNC was saturated with antibiotic fusidic acid (FA). The subject of the experiment was BNC, produced by bacteria Gluconacetobacter sucrofermentans B-11267. The resulting biocomposites have high antibiotic activity against Staphylococcus aureus and can be used in medicine as a wound dressing. The structure of BNC was analyzed by atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR).
Rydberg-Dressed Magneto-optical Trap
NASA Astrophysics Data System (ADS)
Bounds, A. D.; Jackson, N. C.; Hanley, R. K.; Faoro, R.; Bridge, E. M.; Huillery, P.; Jones, M. P. A.
2018-05-01
We propose and demonstrate the laser cooling and trapping of Rydberg-dressed Sr atoms. By off-resonantly coupling the excited state of a narrow (7 kHz) cooling transition to a high-lying Rydberg state, we transfer Rydberg properties such as enhanced electric polarizability to a stable magneto-optical trap operating at <1 μ K . Simulations show that it is possible to reach a regime where the long-range interaction between Rydberg-dressed atoms becomes comparable to the kinetic energy, opening a route to combining laser cooling with tunable long-range interactions.
Dressed Hard States and Black Hole Soft Hair.
Mirbabayi, Mehrdad; Porrati, Massimo
2016-11-18
A recent, intriguing Letter by Hawking, Perry, and Strominger suggests that soft photons and gravitons can be regarded as black hole hair and may be relevant to the black hole information paradox. In this Letter we make use of factorization theorems for infrared divergences of the S matrix to argue that by appropriately dressing in and out hard states, the soft-quanta-dependent part of the S matrix becomes essentially trivial. The information paradox can be fully formulated in terms of dressed hard states, which do not depend on soft quanta.
Acemannan-containing wound dressing gel reduces radiation-induced skin reactions in C3H mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D.B.; Travis, E.L.
To determine (a) whether a wound dressing gel that contains acemannan extracted from aloe leaves affects the severity of radiation-induced acute skin reactions in C3H mice; (b) if so, whether other commercially available gels such as a personal lubricating jelly and a healing ointment have similar effects; and (c) when the wound dressing gel should be applied for maximum effect. Male C3H mice received graded single doses of gamma radiation ranging from 30 to 47.5 Gy to the right leg. In most experiments, the gel was applied daily beginning immediately after irradiation. Dose-response curves were obtained by plotting the percentagemore » of mice that reached or exceeded a given peak skin reaction as a function of dose. Curves were fitted by logit analysis and ED{sub 50} values, and 95% confidence limits were obtained. The average peak skin reactions of the wound dressing gel-treated mice were lower than those of the untreated mice at all radiation doses tested. The ED{sub 50} values for skin reactions of 2.0-2.75 were approximately 7 Gy higher in the wound dressing gel-treated mice. The average peak skin reactions and the ED{sub 50} values for mice treated with personal lubricating jelly or healing ointment were similar to irradiated control values. Reduction in the percentage of mice with skin reactions of 2.5 or more was greatest in the groups that received wound dressing gel for at least 2 weeks beginning immediately after irradiation. There was no effect if gel was applied only before irradiation or beginning 1 week after irradiation. Wound dressing gel, but not personal lubricating jelly or healing ointment, reduces acute radiation-induced skin reactions in C3H mice if applied daily for at least 2 weeks beginning immediately after irradiation. 31 refs., 4 figs., 1 tab.« less
Nímia, Heloisa Helena; Carvalho, Viviane Fernandes; Isaac, Cesar; Souza, Francisley Ávila; Gemperli, Rolf; Paggiaro, André Oliveira
2018-06-11
The aim of this systematic review with meta-analysis was to compare the effect of Silver Sulfadiazine (SSD) with other new dressings, with or without silver, on healing and infection prevention in burns. The electronic search was carried out in the electronic databases of Pubmed, ScienceDirect, Lilacs and BVS. The articles included were randomized clinical trials about burn treatment with SSD, which evaluated the healing and infection of burn wounds in humans. The exclusion criteria included articles, editorials and letters published in the form of abstracts, unpublished reports and case series, cross-sectional, observational experimental studies, and the use of sulfadiazine for other types of wounds. The search identified 873 references, and 24 studies were included in accordance with the eligibility criteria. The results showed a statistically favorable difference related to the time of healing for silver dressings (p<0.0001; MD 3.83; 95% CI 2.03-5.62) and dressings without silver (p<0.007; MD 2.9; 95% CI 0.81-5.00) in comparison with SSD. The rate of infection showed no difference in the group treated with SSD compared with the group treated with dressings containing silver (p>0.05). The rate of infection was significantly higher in the SSD group compared with the group treated with dressings without silver (p<0.005; MD 25.29% and MD 12.97%). Considering the clinical trials conducted up to the present time, the authors concluded that new dressings with and without silver show better results than SSD for wound healing, and burns treated with dressings without silver are less likely to become infected than burns with SSD. No differences between SSD and new silver materials were observed in relation to infection prevention. Copyright © 2018 Elsevier Ltd and ISBI. All rights reserved.
Gumel, Ahmad Mohammed; Razaif-Mazinah, Mohd Rafais Mohd; Anis, Siti Nor Syairah; Annuar, Mohamad Suffian Mohamad
2015-07-08
Wound management and healing in several physiological or pathological conditions, particularly when comorbidities are involved, usually proves to be difficult. This presents complications leading to socio-economic and public health burdens. The accelerative wound healing potential of biocompatible poly(3-hydroxyalkanoates)-co-(6-hydroxyhexanoate) (PHA-PCL) composite hydrogel is reported herein. The biosynthesized PHA-PCL macromer was cross-linked with PEGMA to give a hydrogel. Twenty-four rats weighing 200-250 g each were randomly assigned to four groups of six rats. Rats in group I (negative control) were dressed with sterilized gum acacia paste in 10% normal saline while PEGMA-alone hydrogel (PH) was used to dress group II (secondary control) rats. Group III rats were dressed with PHAs-PCL cross-linked PEGMA hydrogel (PPH). For the positive control (group IV), the rats were dressed with Intrasite(®) gel. Biochemical, histomorphometric and immunohistomorphometric analyses revealed a significant difference in area closure and re-epithelialization on days 7 and 14 in PPH or Intrasite(®) gel groups compared to gum acacia or PEGMA-alone groups. Furthermore, wounds dressed with PPH or Intrasite(®) gel showed evident collagen deposition, enhanced fibrosis and extensively organized angiogenesis on day 14 compared to the negative control group. While improvement in wound healing of the PH dressed group could be observed, there was no significant difference between the negative control group and the PH dressed group in any of the tests. The findings suggested that topical application of PPH accelerated the rats' wound healing process by improving angiogenesis attributed to the increased microvessel density (MVD) and expressions of VEGF-A in tissue samples. Thus, PPH has been demonstrated to be effective in the treatment of cutaneous wounds in rats, and could be a potential novel agent in the management and acceleration of wound healing in humans and animals.
Moore, Rusty A; Liedl, David A; Jenkins, Sarah; Andrews, Karen L
2008-11-01
This retrospective observational study was designed to review the use of a silver-coated polymeric substrate on various types of chronic wounds at the Mayo Clinic in Rochester, Minnesota. The study was set in a community and referral multidisciplinary vascular wound clinic. The authors identified the first 112 patients treated with a silver dressing in the center. Of these, 15 were lost to follow-up or had incomplete data. Ninety-seven patients were included in the study. Thirty-seven of these 97 patients had multiple wounds; however, 1 wound per person was randomly chosen for analysis. The median age of these patients was 69 years. A wound was considered healed when the wound was completely epithelialized. Of the 97 wounds evaluated, the primary etiologies were as follows: 20 (20.6%) were neurotrophic, 24 (24.7%) were ischemic (arterial, arteriolar, or vasculitic), 20 (20.6%) were venous, 7 (7.2%) were traumatic, and 16 (16.5%) were multifactorial. The silver dressing was the primary wound care product on all wounds. Silverlon (Argentum LLC, Chicago, Illinois) was the silver dressing used for this study. The frequency of dressing changes and use of secondary dressings, to keep the wound moist, were based on the amount of drainage, debris, and slough on the wound. Data pertaining to patient demographics, risk factors, wound etiology, noninvasive arterial vascular studies, frequency of dressing changes, wound discomfort, wound size, and wound duration were collected by retrospective chart review. Thirty-five of the 97 wounds (36.1%) healed. The 62 nonhealed wounds (63.9%) decreased in size by a median of 55.2%. Among the 68 patients who had reported discomfort before the study, 77.9% reported no change in discomfort, 17.7% reported increased pain, and 4.4% reported decreased pain. A silver-coated polymeric substrate (Silverlon) can be used as an effective primary wound care dressing in patients with active wounds.
Rickard, Claire M; Marsh, Nicole M; Webster, Joan; Gavin, Nicole C; Chan, Raymond J; McCarthy, Alexandra L; Mollee, Peter; Ullman, Amanda J; Kleidon, Tricia; Chopra, Vineet; Zhang, Li; McGrail, Matthew R; Larsen, Emily; Choudhury, Md Abu; Keogh, Samantha; Alexandrou, Evan; McMillan, David J; Mervin, Merehau Cindy; Paterson, David L; Cooke, Marie; Ray-Barruel, Gillian; Castillo, Maria Isabel; Hallahan, Andrew; Corley, Amanda; Geoffrey Playford, E
2017-06-15
Around 30% of peripherally inserted central catheters (PICCs) fail from vascular, infectious or mechanical complications. Patients with cancer are at highest risk, and this increases morbidity, mortality and costs. Effective PICC dressing and securement may prevent PICC failure; however, no large randomised controlled trial (RCT) has compared alternative approaches. We designed this RCT to assess the clinical and cost-effectiveness of dressing and securements to prevent PICC failure. Pragmatic, multicentre, 2×2 factorial, superiority RCT of (1) dressings (chlorhexidine gluconate disc (CHG) vs no disc) and (2) securements (integrated securement dressing (ISD) vs securement device (SED)). A qualitative evaluation using a knowledge translation framework is included. Recruitment of 1240 patients will occur over 3 years with allocation concealment until randomisation by a centralised service. For the dressing hypothesis, we hypothesise CHG discs will reduce catheter-associated bloodstream infection (CABSI) compared with no CHG disc. For the securement hypothesis, we hypothesise that ISD will reduce composite PICC failure (infection (CABSI/local infection), occlusion, dislodgement or thrombosis), compared with SED. types of PICC failure; safety; costs; dressing/securement failure; dwell time; microbial colonisation; reversible PICC complications and consumer acceptability. Relative incidence rates of CABSI and PICC failure/100 devices and/1000 PICC days (with 95% CIs) will summarise treatment impact. Kaplan-Meier survival curves (and log rank Mantel-Haenszel test) will compare outcomes over time. Secondary end points will be compared between groups using parametric/non-parametric techniques; p values <0.05 will be considered to be statistically significant. Ethical approval from Queensland Health (HREC/15/QRCH/241) and Griffith University (Ref. No. 2016/063). Results will be published. Trial registration number is: ACTRN12616000315415. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Patil, Pritam S; Fountas-Davis, Natalie; Huang, He; Michelle Evancho-Chapman, M; Fulton, Judith A; Shriver, Leah P; Leipzig, Nic D
2016-05-01
In this study, methacrylamide chitosan modified with perfluorocarbon chains (MACF) is used as the base material to construct hydrogel dressings for treating dermal wounds. MACF hydrogels saturated with oxygen (+O2) are examined for their ability to deliver and sustain oxygen, degrade in a biological environment, and promote wound healing in an animal model. The emerging technique of metabolomics is used to understand how MACF+O2 hydrogel dressings improve wound healing. Results indicate that MACF treatment facilitates oxygen transport rate that is two orders of magnitude greater than base MAC hydrogels. MACF hydrogel dressings are next tested in an in vivo splinted rat excisional wound healing model. Histological analysis reveals that MACF+O2 dressings improve re-epithelialization (p<0.0001) and synthesis of collagen over controls (p<0.01). Analysis of endogenous metabolites in the wounds using global metabolomics demonstrates that MACF+O2 dressings promotes a regenerative metabolic process directed toward hydroxyproline and collagen synthesis, with confirmation of metabolite levels within this pathway. The results of this study confirm that increased oxygen delivery through the application of MACF+O2 hydrogels enhances wound healing and metabolomics analyses provides a powerful tool to assess wound healing physiology. This work presents the first application of a novel class of oxygen delivering biomaterials (methacrylamide chitosan modified with perfluorocarbon chains (MACF)) as a hydrogel wound dressing. This manuscript also contains strong focus on the biochemical benefits of MACF dressings on underlying mechanisms vital to successful wound healing. In this vein, this manuscript presents the application of applied metabolomics (tandem mass spectroscopy) to uncover biomaterial interactions with wound healing mechanisms. We believe the approaches described in this manuscript will be of great interest to biomedical scientists and particularly to researchers studying wound healing, metabolomics, applied biomaterials and regenerative medicine. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Jiang, Qiong; Chen, Zhao-Hong; Wang, Shun-Bin; Chen, Xiao-Dong
2017-03-22
Selecting a suitable wound dressing for patients with partial-thickness burns (PTBs) is important in wound care. However, the comparative effectiveness of different dressings has not been studied. We report the protocol of a network meta-analysis designed to combine direct and indirect evidence of wound dressings in the management of PTB. We will search for randomised controlled trials (RCTs) evaluating the wound-healing effect of a wound dressing in the management of PTB. Searches will be conducted in MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane Wounds Group Specialised Register and CINAHL. A comprehensive search strategy is developed to retrieve articles reporting potentially eligible RCTs. Besides, we will contact the experts in the field and review the conference proceedings to locate non-published studies. The reference lists of articles will be reviewed for any candidate studies. Two independent reviewers will screen titles and abstracts of the candidate articles. All eligible RCTs will be obtained in full text to perform a review. Disagreement on eligibility of an RCT will be solved by group discussion. The information of participants, interventions, comparisons and outcomes from included RCTs will be recorded and summarised. The primary outcome is time to complete wound healing. Secondary outcomes include the proportion of burns completely healed at the end of treatment, change in wound surface area at the end of treatment, incidence of adverse events, etc. The result of this review will provide evidence for the comparative effectiveness of different wound dressings in the management of PTB. It will also facilitate decision-making in choosing a suitable wound dressing. We will disseminate the review through a peer-review journal and conference abstracts or posters. PROSPERO CRD42016041574; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Jiang, Qiong; Chen, Zhao-Hong; Wang, Shun-Bin; Chen, Xiao-Dong
2017-01-01
Introduction Selecting a suitable wound dressing for patients with partial-thickness burns (PTBs) is important in wound care. However, the comparative effectiveness of different dressings has not been studied. We report the protocol of a network meta-analysis designed to combine direct and indirect evidence of wound dressings in the management of PTB. Methods and analysis We will search for randomised controlled trials (RCTs) evaluating the wound-healing effect of a wound dressing in the management of PTB. Searches will be conducted in MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane Wounds Group Specialised Register and CINAHL. A comprehensive search strategy is developed to retrieve articles reporting potentially eligible RCTs. Besides, we will contact the experts in the field and review the conference proceedings to locate non-published studies. The reference lists of articles will be reviewed for any candidate studies. Two independent reviewers will screen titles and abstracts of the candidate articles. All eligible RCTs will be obtained in full text to perform a review. Disagreement on eligibility of an RCT will be solved by group discussion. The information of participants, interventions, comparisons and outcomes from included RCTs will be recorded and summarised. The primary outcome is time to complete wound healing. Secondary outcomes include the proportion of burns completely healed at the end of treatment, change in wound surface area at the end of treatment, incidence of adverse events, etc. Ethics and dissemination The result of this review will provide evidence for the comparative effectiveness of different wound dressings in the management of PTB. It will also facilitate decision-making in choosing a suitable wound dressing. We will disseminate the review through a peer-review journal and conference abstracts or posters. Trial registration number PROSPERO CRD42016041574; Pre-results. PMID:28336737
Managing burn wounds with SMARTPORE Technology polyurethane foam: two case reports.
Imran, Farrah-Hani; Karim, Rahamah; Maat, Noor Hidayah
2016-05-12
Successful wound healing depends on various factors, including exudate control, prevention of microbial contaminants, and moisture balance. We report two cases of managing burn wounds with SMARTPORE Technology polyurethane foam dressing. In Case 1, a 2-year-old Asian girl presented with a delayed (11 days) wound on her right leg. She sustained a thermal injury from a hot iron that was left idle on the floor. Clinical inspection revealed an infected wound with overlying eschar that traversed her knee joint. As her parents refused surgical debridement under general anesthesia, hydrotherapy and wound dressing using SMARTPORE Technology Polyurethane foam were used. Despite the delay in presentation of this linear thermal pediatric burn injury that crossed the knee joint, the patient's response to treatment and its outcome were highly encouraging. She was cooperative and tolerated each dressing change without the need of supplemental analgesia. Her wound was healed by 24 days post-admission. In Case 2, a 25-year-old Asian man presented with a mixed thickness thermal flame burn on his left leg. On examination, the injury was a mix of deep and superficial partial thickness burn, comprising approximately 3% of his total body surface area. SMARTPORE Technology polyurethane foam was used on his wound; his response to the treatment was very encouraging as the dressing facilitated physiotherapy and mobility. The patient rated the pain during dressing change as 2 on a scale of 10 and his pain score remained the same in every subsequent change. His wound showed evidence of epithelialization by day 7 post-burn. There were no adverse events reported. Managing burn wounds with SMARTPORE Technology polyurethane foam resulted in reduced pain during dressing changes and the successful healing of partial and mixed thickness wounds. The use of SMARTPORE Technology polyurethane foam dressings showed encouraging results and requires further research as a desirable management option in burn wounds.
Park, Tae Hwan; Chang, Choong Hyun
2013-04-01
To prevent the recurrence of earlobe keloids after surgical removal, a reliable and safe postoperative treatment method is critical. To the authors' knowledge, no studies have elucidated the most effective postoperative dressing method for preventing the recurrence of earlobe keloids. This study aimed to compare keloid recurrence rates in patients whose keloids were dressed using conventional methods (plain gauze or a polyvinyl alcohol sponge) with those of a matched cohort of patients whose keloids were dressed using magnets combined with hydrocolloid materials. This observational case-control study compared a retrospective cohort of patients whose keloids were dressed using conventional methods with a matched prospective cohort of patients whose keloids were dressed using magnets combined with hydrocolloid materials. The study included patients with pathologically confirmed earlobe keloids that were surgically excised with primary closure. Patients 8 years of age or older underwent adjuvant pressure therapy with magnets at the study hospital. Patients were excluded from the study if they were unavailable for follow-up evaluation, if they had received additional adjuvant therapy during treatment, or if histologic confirmation of a keloid was not obtained. Matched-pair analysis was performed using the McNemar test. Treatment outcome was evaluated as recurrence or nonrecurrence. Overall, 9 (11.2%) of the 80 study patients experienced recurrence. The recurrence rate was significantly lower in the matched case group (2 of 40, 5%) than in the matched control group (7 of 40, 17.5%) during the follow-up period of 18 months (p=0.0253). The authors' novel dressing of magnets and hydrocolloid materials appears to be effective in reducing earlobe keloid recurrence. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
12. VIEW, LOOKING SOUTH FROM LEFT TO RIGHT, SHOWING DRESSING ...
12. VIEW, LOOKING SOUTH FROM LEFT TO RIGHT, SHOWING DRESSING FROM AND WORK/CHAMBER ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT
Seres, Enikoe; Seres, Jozsef; Namba, Shinichi; Afa, John; Serrat, Carles
2017-12-11
Applying extreme ultraviolet (XUV) transient absorption spectroscopy, the dynamics of the two laser dressed transitions 3d 5/2 -to-5p 3/2 and 3p 3/2 -to-5s 1/2 at photon energies of 91.3 eV and 210.4 eV were examined with attosecond temporal resolution. The dressing process was modeled with density matrix equations which are found to describe very accurately both the experimentally observed transmission dynamics and the linear and nonlinear dressing oscillations at 0.75 PHz and 1.5 PHz frequencies. Furthermore, using Fourier transform XUV spectroscopy, quantum beats from the 3d 5/2 -3d 3/2 and 3p 3/2 -3p 1/2 sublevels at 0.3 PHz and 2.0 PHz were experimentally identified and resolved.
Investigation on Curcumin nanocomposite for wound dressing.
Venkatasubbu, G Devanand; Anusuya, T
2017-05-01
Curcuma longa (turmeric) has a long history of use in medicine as a treatment for inflammatory conditions. The primary active constituent of turmeric and the one responsible for its vibrant yellow color is curcumin. Curcumin is used for treatment of wound and inflammation. It had antimicrobial and antioxidant property. It has low intrinsic toxicity and magnificent properties like with comparatively lesser side-effects. Cotton cloth is one of the most successful wound dressings which utilize the intrinsic properties of cotton fibers. Modern wound dressings, however, require other properties such as antibacterial and moisture maintaining capabilities. In this study, conventional cotton cloth was coated with Curcumin composite for achieving modern wound dressing properties. Curcumin nanocomposite is characterized. The results show that coated cotton cloth with Curcumin nanocomposite has increased drying time (74%) and water absorbency (50%). Furthermore, they show antibacterial efficiency against bacterial species present in wounds. Copyright © 2017 Elsevier B.V. All rights reserved.
DRESS syndrome with thrombotic microangiopathy revealing a Noonan syndrome
Bobot, Mickaël; Coen, Matteo; Simon, Clémentine; Daniel, Laurent; Habib, Gilbert; Serratrice, Jacques
2018-01-01
Abstract Rationale: The life-threatening drug rash with eosinophilia and systemic symptoms (DRESS) syndrome occurs most commonly after exposure to drugs, clinical features mimic those found with other serious systemic disorders. It is rarely associated with thrombotic microangiopathy. Patient concerns: We describe the unique case of a 44-year-old man who simultaneously experienced DRESS syndrome with thrombotic microangiopathy (TMA) after a 5 days treatment with fluindione. Diagnoses: Clinical evaluation leads to the discovery of an underlying lymphangiomatosis, due to a Noonan syndrome. Intervetions: The anticoagulant was withdrawn, and corticosteroids (1 mg/kg/day) and acenocoumarol were started. Outcomes: Clinical improvement ensued. At follow-up the patient is well. Lessons: The association of DRESS with TMA is a rare condition; we believe that the presence of the underlying Noonan syndrome could have been the trigger. Moreover, we speculate about the potential interrelations between these entities. PMID:29642153
Disconnection: the user voice within the wound dressing supply chain.
Campling, Natasha; Grocott, Patricia; Cowley, Sarah
2008-03-01
This study examined the user voice in England's National Health Service (NHS) wound dressing supply chain. The impetus for this work came from involvement in a collaboration between industry and clinicians, entitled Woundcare Research for Appropriate Products. Experiences from that study highlighted the notable absence of research about the impact of the supply chain on the users of dressings. Interview data are presented following an outline of the grounded theory method used. These data were obtained from key stakeholders (n = 41) within the wound dressing supply chain such as nurses, manufacturers, distributors, professional organizations, government organizations and user groups. The consequences of supply disconnection revealed haphazard supply, unmet user needs and lack of information transfer between player groups. These consequences explain the lack of user voice in the supply chain and have far-reaching implications for nursing management, through purchasing decisions and nurses' management of wound care.
Rea, Suzanne M.; Stevenson, Andrew W.; Wood, Fiona M.; Fear, Mark W.
2012-01-01
Topographic modulation of tissue response is an important consideration in the design and manufacture of a biomaterial. In developing new tissue therapies for skin, all levels of architecture, including the nanoscale need to be considered. Here we show that keratinocyte phenotype is affected by nanoscale changes in topography with cell morphology, proliferation, and migration influenced by the pore size in anodic aluminum oxide membranes. A membrane with a pore size of 300 nm, which enhanced cell phenotype in vitro, was used as a dressing to cover a partial thickness burn injury in the pig. Wounds dressed with the membrane showed evidence of advanced healing with significantly less organizing granulation tissue and more mature epidermal layers than control wounds dressed with a standard burns dressing. The results demonstrate the importance of nanoscale topography in modulating keratinocyte phenotype and skin wound healing. PMID:21988618
LGBTQ Women, Appearance Negotiations, and Workplace Dress Codes.
Reddy-Best, Kelly L
2018-01-01
The purpose of this study was to explore LGBTQ women's experiences with unwritten or formal dress codes at work. I asked: What are LGBTQ women's experiences in the workplace with appearance management, and what are LGBTQ women's experiences navigating the written and unwritten dress codes in the workplace? To answer the research question, interviews were conducted with 24 self-identifying LGBTQ women. Six key themes emerged from the data. Themes included (1) expressed sexual identity in appearance, (2) unwritten dress codes in work environments did not always allow for expression of sexual identity in appearance, (3) motivations for pressure or desire to conceal expression of sexual identity in appearance at work, (4) negotiations of revealing or concealing sexual identity in appearance in the workplace impacted levels of comfort and confidence, (5) verbal and nonverbal negative experiences related to appearance at work, and (6) received compliments about appearance at work.
Prostitution advertisements suggest association of transvestism and masochism.
Chivers, M; Blanchard, R
1996-01-01
Previous research and clinical observation have suggested that the sexual interest of many transvestites include involvement in sadomasochistic sexual acts. Through data gathered via prostitution advertisements in print media, we tested the hypothesis that prostitutes welcoming cross-dressing client would be primarily those describing themselves as dominant. The specialty of the prostitute was recorded by coding the advertisements for the presence or absence of the features of dominance, submissiveness, acceptance of cross-dressing clients, and whether the prostitute was a biological male presenting as a woman or quasi-woman. The findings showed that 20% of prostitutes describing themselves as dominant welcomed cross-dressing clients, whereas none of the other subgroups of prostitutes mentioned cross-dressing clients in their advertisements. These findings reinforce other lines of indirect evidence suggesting that, in heterosexual men, the presence of masochism increases the likelihood of transvestism, and vice versa.
NASA Astrophysics Data System (ADS)
Haiqiao, Wang; Sujing, Sun
1993-10-01
In order to attain an optimum sterilization treatment to obstetric dressings, a new product made by us, with 60Coγ-ray, the effects of radiation on standard bacteria pseudomonas aeruginosa ATcc27853, Escherichia coli ATcc25922, Staphylococcus aureus ATcc25923, Clostridium PB6KA, short Bacillus E60163202 and HBSAg were studied. Results showed that at the absorbed dose of 10 kGy, all the bacteria, bacillus and HBSAg were killed off, and sterilized with the dose, the dressings can completely accord with the demands of hygiene, which was further confirmed by microbiological and poisonous tests and the effects of clinical application. In Nov. 1988, the dressings was awarded the excellent prize in the 1st international exhibition of patent, new technique and new equipment in Guangzhou; its effective application is also reported in the paper.
DRESS syndrome: A case of cross-reactivity with lacosamide?
Fong, Man Kei; Sheng, Bun
2017-06-01
A 42-year-old patient with epilepsy was admitted to the hospital for fever and generalized skin rash. He has known allergy to phenytoin. Valproate was started in 2012, but failed to control his seizure despite gradual increase in dosage. Phenobarbitone was added 16 days before admission and was stopped on admission. He was treated with beta-lactam antibiotics. The rash subsided gradually after the cessation of phenobarbitone. Lacosamide was subsequently added for seizure control. Unfortunately, he developed drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome soon after introduction of lacosamide that required the use of systemic steroid for acute hepatitis. A cross-reactivity with lacosamide was suspected in view of the rapid onset of DRESS syndrome after the initial rash resolution and soon after the introduction of lacosamide. We postulated that the rapid onset of DRESS syndrome may be related to the aromatic ring that is in common among phenytoin, phenobarbitone, and lacosamide.
The Efficacy of Gelam Honey Dressing towards Excisional Wound Healing
Tan, Mui Koon; Hasan Adli, Durriyyah Sharifah; Tumiran, Mohd Amzari; Abdulla, Mahmood Ameen; Yusoff, Kamaruddin Mohd
2012-01-01
Honey is one of the oldest substances used in wound management. Efficacy of Gelam honey in wound healing was evaluated in this paper. Sprague-Dawley rats were randomly divided into four groups of 24 rats each (untreated group, saline group, Intrasite Gel group, and Gelam honey group) with 2 cm by 2 cm full thickness, excisional wound created on neck area. Wounds were dressed topically according to groups. Rats were sacrificed on days 1, 5, 10, and 15 of treatments. Wounds were then processed for macroscopic and histological observations. Gelam-honey-dressed wounds healed earlier (day 13) than untreated and saline treated groups, as did wounds treated with Intrasite Gel. Honey-treated wounds exhibited less scab and only thin scar formations. Histological features demonstrated positive effects of Gelam honey on the wounds. This paper showed that Gelam honey dressing on excisional wound accelerated the process of wound healing. PMID:22536292
Early-Onset Vemurafenib-Induced DRESS Syndrome.
Munch, Marion; Peuvrel, Lucie; Brocard, Anabelle; Saint Jean, Mélanie; Khammari, Amir; Dreno, Brigitte; Quereux, Gaelle
2016-01-01
Vemurafenib is a BRAF inhibitor indicated in metastatic or unresectable melanoma in patients with BRAF mutations. Vemurafenib is frequently toxic, but the toxicity is often not serious. The third case of vemurafenib-induced drug rash with eosinophilia and systemic symptoms (DRESS) syndrome is reported herein. The case is unusual in that the onset was early, with symptoms emerging as of day 8 of treatment. Treatment of DRESS syndrome is not currently based on precise recommendations, but systemic corticosteroid therapy is effective in serious cases. Severe toxidermias under vemurafenib are exceptional; immediate discontinuation of treatment upon diagnosis is imperative. Switching from vemurafenib to dabrafenib then seems to constitute an interesting therapeutic alternative, since its efficacy is the same but with fewer cutaneous adverse reactions. This case highlights the importance of awareness of the risk of DRESS syndrome associated with vemurafenib and monitoring for warning signs from treatment initiation. © 2015 S. Karger AG, Basel.
Lahfa, M; Bulai-Livideanu, C; Baran, R; Ortonne, J P; Richert, B; Tosti, A; Piraccini, B M; Szepietowski, J C; Sibaud, V; Coubetergues, H; Voisard, J J; Paul, C
2013-01-01
Toenail onychomycosis is highly prevalent, with 14-28% of people aged 60 or over suffering from the disease. Use of a topical antifungal alone in toenail onychomycosis is associated with low cure rates. This may be due to limited penetration of the topical antifungal through the diseased nail. The objective of the present study was to compare two treatment modalities to obtain diseased nail chemical avulsion in toenail onychomycosis. In this European, multicenter, randomized, parallel-group, open-label, active-controlled study, male or female adult patients with distal-lateral or lateral subungual dermatophyte onychomycosis on at least 12.5% of the great toenail were randomized either to a 40% urea ointment with plastic dressing group (n = 53) or to a bifonazole-urea ointment group (n = 52). The ointments were applied daily for a maximum of 3 weeks according to the summary of product characteristics. After assessment of infected nail debridement, topical antifungal treatment with bifonazole cream was applied daily in both groups for 8 weeks. 102 patients were evaluated, i.e. 51 in the 40% urea ointment with plastic dressing group and 51 in the bifonazole-urea group. The primary end point was complete removal of the nail plate at day 21 (D21). Secondary end points were: complete cure and mycological cure evaluated at D105. Ease of use and local tolerability were also assessed. Complete removal of the clinically infected target nail plate area, assessed by blinded evaluators, was significantly higher in the 40% urea ointment with plastic dressing group (61.2%) than in the control group (39.2%), showing the superiority of 40% urea ointment with plastic dressing (p = 0.028). The same results were observed in the per-protocol population (63.0 vs. 36.6%; p = 0.014). Complete removal of the infected area assessed by the investigator at D21 showed a significantly higher success rate in patients treated with 40% urea ointment with plastic dressing (86.3%) as compared to patients treated with bifonazole-urea (60.8%), confirming the superiority of 40% urea ointment with plastic dressing (p = 0.004). At D105, the complete cure of onychomycosis, a criterion combining clinical and mycological assessments, showed a success rate of 27.7% for 40% urea ointment with plastic dressing versus 20.8% for the control group. No statistical difference was observed between the two treatment groups. The number of patients with at least one adverse event was twice as high in the bifonazole-urea group in comparison to the 40% urea ointment with plastic dressing group. Overall assessment of local tolerability by the investigator was considered good/very good in 98.0% of the 40% urea ointment with plastic dressing patients versus 90.4% of the bifonazole-urea patients, at D21, with no significant difference between both groups. This study shows the superiority of 40% urea ointment with plastic dressing to bifonazole-urea ointment for complete removal of the infected target nail assessed by blinded evaluators and by the investigators. Further studies are needed to assess the impact of preliminary chemical nail avulsion on the efficacy of topical treatment of onychomycosis as assessed by complete cure at 1 year. Copyright © 2013 S. Karger AG, Basel.
Balaji, Arunpandian; Jaganathan, Saravana Kumar; Ismail, Ahmad Fauzi; Rajasekar, Rathanasamy
Management of burn injury is an onerous clinical task since it requires continuous monitoring and extensive usage of specialized facilities. Despite rapid improvizations and investments in burn management, >30% of victims hospitalized each year face severe morbidity and mortality. Excessive loss of body fluids, accumulation of exudate, and the development of septic shock are reported to be the main reasons for morbidity in burn victims. To assist burn wound management, a novel polyurethane (PU)-based bio-nanofibrous dressing loaded with honey (HN) and Carica papaya (PA) fruit extract was fabricated using a one-step electrospinning technique. The developed dressing material had a mean fiber diameter of 190±19.93 nm with pore sizes of 4-50 µm to support effective infiltration of nutrients and gas exchange. The successful blending of HN- and PA-based active biomolecules in PU was inferred through changes in surface chemistry. The blend subsequently increased the wettability (14%) and surface energy (24%) of the novel dressing. Ultimately, the presence of hydrophilic biomolecules and high porosity enhanced the water absorption ability of the PU-HN-PA nanofiber samples to 761.67% from 285.13% in PU. Furthermore, the ability of the bio-nanofibrous dressing to support specific protein adsorption (45%), delay thrombus formation, and reduce hemolysis demonstrated its nontoxic and compatible nature with the host tissues. In summary, the excellent physicochemical and hemocompatible properties of the developed PU-HN-PA dressing exhibit its potential in reducing the clinical complications associated with the treatment of burn injuries.
Carty, Neal; Wibaux, Anne; Ward, Colleen; Paulson, Daryl S.; Johnson, Peter
2014-01-01
Objectives To evaluate the antimicrobial activity of a new, transparent composite film dressing, whose adhesive contains chlorhexidine gluconate (CHG), against the native microflora present on human skin. Methods CHG-containing adhesive film dressings and non-antimicrobial control film dressings were applied to the skin on the backs of healthy human volunteers without antiseptic preparation. Dressings were removed 1, 4 or 7 days after application. The bacterial populations underneath were measured by quantitative cultures (cylinder-scrub technique) and compared with one another as a function of time. Results The mean baseline microflora recovery was 3.24 log10 cfu/cm2. The mean log reductions from baseline measured from underneath the CHG-containing dressings were 0.87, 0.78 and 1.30 log10 cfu/cm2 on days 1, 4 and 7, respectively, compared with log reductions of 0.67, −0.87 and −1.29 log10 cfu/cm2 from underneath the control film dressings. There was no significant difference between the log reductions of the two treatments on day 1, but on days 4 and 7 the log reduction associated with the CHG adhesive was significantly higher than that associated with the control adhesive. Conclusions The adhesive containing CHG was associated with a sustained antimicrobial effect that was not present in the control. Incorporating the antimicrobial into the adhesive layer confers upon it bactericidal properties in marked contrast to the non-antimicrobial adhesive, which contributed to bacterial proliferation when the wear time was ≥4 days. PMID:24722839
Carty, Neal; Wibaux, Anne; Ward, Colleen; Paulson, Daryl S; Johnson, Peter
2014-08-01
To evaluate the antimicrobial activity of a new, transparent composite film dressing, whose adhesive contains chlorhexidine gluconate (CHG), against the native microflora present on human skin. CHG-containing adhesive film dressings and non-antimicrobial control film dressings were applied to the skin on the backs of healthy human volunteers without antiseptic preparation. Dressings were removed 1, 4 or 7 days after application. The bacterial populations underneath were measured by quantitative cultures (cylinder-scrub technique) and compared with one another as a function of time. The mean baseline microflora recovery was 3.24 log10 cfu/cm(2). The mean log reductions from baseline measured from underneath the CHG-containing dressings were 0.87, 0.78 and 1.30 log10 cfu/cm(2) on days 1, 4 and 7, respectively, compared with log reductions of 0.67, -0.87 and -1.29 log10 cfu/cm(2) from underneath the control film dressings. There was no significant difference between the log reductions of the two treatments on day 1, but on days 4 and 7 the log reduction associated with the CHG adhesive was significantly higher than that associated with the control adhesive. The adhesive containing CHG was associated with a sustained antimicrobial effect that was not present in the control. Incorporating the antimicrobial into the adhesive layer confers upon it bactericidal properties in marked contrast to the non-antimicrobial adhesive, which contributed to bacterial proliferation when the wear time was ≥4 days. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.
A study to evaluate primary dressings for the application of cultured keratinocytes.
Price, R D; Das-Gupta, V; Frame, J D; Navsaria, H A
2001-12-01
Despite the recent improvements in cell culture and dermal regeneration methods, tissue engineering of skin has yet to receive widespread acceptance in the management of burn injuries. The reasons for this are complex and include not only the inherent costs of (particularly) setting up and running such a system but also the continuing difficulties in achieving successful engraftment of the neoepidermis. The latter has previously been addressed in a number of ways, including improving the recipient bed and using pre-confluent delivery systems to allow earlier application of cells to that wound bed. One area that has received little attention is that of the optimal wound dressing to use with this technology; the cells are very poorly attached at early time points, and, in this context, the traditional dressing of paraffin gauze has never been formally assessed in comparison with newer materials. Using a porcine acute wound chamber model, we performed a prospective randomised trial to assess four different wound dressings with reference to the amount of epidermal cover gained and the histological quality of the regenerated skin after 3 weeks. Out of the four materials tested, polyurethane foam (Allevyn) was superior histologically (although equal in take rate with paraffin gauze), whilst polythene sheet (Opsite) and silicone sheet were substantially inferior. We conclude that the traditional dressing used with this technology should be compared with polyurethane foam in a clinical trial. In the future, novel dressings should be formally tested against traditional methods before being adopted. Copyright 2001 The British Association of Plastic Surgeons.
Modern collagen wound dressings: function and purpose.
Fleck, Cynthia Ann; Simman, Richard
2010-09-01
Collagen, which is produced by fibroblasts, is the most abundant protein in the human body. A natural structural protein, collagen is involved in all 3 phases of the wound-healing cascade. It stimulates cellular migration and contributes to new tissue development. Because of their chemotactic properties on wound fibroblasts, collagen dressings encourage the deposition and organization of newly formed collagen, creating an environment that fosters healing. Collagen-based biomaterials stimulate and recruit specific cells, such as macrophages and fibroblasts, along the healing cascade to enhance and influence wound healing. These biomaterials can provide moisture or absorption, depending on the delivery system. Collagen dressings are easy to apply and remove and are conformable. Collagen dressings are usually formulated with bovine, avian, or porcine collagen. Oxidized regenerated cellulose, a plant-based material, has been combined with collagen to produce a dressing capable of binding to and protecting growth factors by binding and inactivating matrix metalloproteinases in the wound environment. The increased understanding of the biochemical processes involved in chronic wound healing allows the design of wound care products aimed at correcting imbalances in the wound microenvironment. Traditional advanced wound care products tend to address the wound's macroenvironment, including moist wound environment control, fluid management, and controlled transpiration of wound fluids. The newer class of biomaterials and wound-healing agents, such as collagen and growth factors, targets specific defects in the chronic wound environment. In vitro laboratory data point to the possibility that these agents benefit the wound healing process at a biochemical level. Considerable evidence has indicated that collagen-based dressings may be capable of stimulating healing by manipulating wound biochemistry.
Forstner, Christina; Leitgeb, Johannes; Schuster, Rupert; Dosch, Verena; Kramer, Axel; Cutting, Keith F.; Leaper, David J.; Assadian, Ojan
2013-01-01
A flexible methacrylate powder dressing (Altrazeal®) transforms into a wound contour conforming matrix once in contact with wound exudate. We hypothesised that it may also serve as a drug delivery vehicle for antiseptics. The antimicrobial efficacy and influence on bacterial growth kinetics in combination with three antiseptics was investigated in an in vitro porcine wound model. Standardized in vitro wounds were contaminated with Staphylococcus aureus (MRSA; ATCC 33591) and divided into six groups: no dressing (negative control), methacrylate dressing alone, and combinations with application of 0.02% Polyhexamethylene Biguanide (PHMB), 0.4% PHMB, 0.1% PHMB + 0.1% betaine, 7.7 mg/mL Povidone-iodine (PVP-iodine), and 0.1% Octenidine-dihydrochloride (OCT) + 2% phenoxyethanol. Bacterial load per gram tissue was measured over five days. The highest reduction was observed with PVP-iodine at 24 h to log10 1.43 cfu/g, followed by OCT at 48 h to log10 2.41 cfu/g. Whilst 0.02% PHMB resulted in a stable bacterial load over 120 h to log10 4.00 cfu/g over 120 h, 0.1% PHMB + 0.1% betaine inhibited growth during the first 48 h, with slightly increasing bacterial numbers up to log10 5.38 cfu/g at 120 h. These results indicate that this flexible methacrylate dressing can be loaded with various antiseptics serving as drug delivery system. Depending on the selected combination, an individually shaped and controlled antibacterial effect may be achieved using the same type of wound dressing. PMID:23698780
Kanda, K; Tsuchiya, J; Seto, M; Ohnaka, T; Tochihara, Y
1995-06-01
Thermal conditions in the bathroom and physiological responses were examined during winter and summer. The subjects were 22 male and 20 female elderly people, between 65 and 88 years old living in 25 houses in Gunma Prefecture, Japan. Heart rate, blood pressure, skin temperature and thermal sensation were measured during bathing. Changes in thermal sensation due to bathing were assessed in the living room and dressing room on a 9-point scale. Then they were asked about the purposes of bathing and the facilities of bathroom and dressing room. The results are summarized as follows: 1. The purpose of bathing in winter was to warm up for more than 80% of the subjects. In summer, all subjects felt refreshed by bathing. Eighty-five percent of the subjects took a bath every other day in both seasons. 2. Fifty-two percent of the bathrooms had no ventilating fans and 32% had no exclusive dressing rooms. 3. The average room temperature in the dressing rooms was 13-14 degrees C in winter. Thermal sensation was 'cool', 'slightly cold' or 'cold' for more than two-thirds of the subjects when they were partially nude, and there were no heaters in most dressing rooms. 4. The heart rate increased steadily, and reached a maximum value in a partially dressed condition in both seasons. 5. In winter, a marked increase of systolic blood pressure was observed in the partially nude condition. There was a significant difference between the before bathing condition and partially nude condition in winter.(ABSTRACT TRUNCATED AT 250 WORDS)
Balaji, Arunpandian; Jaganathan, Saravana Kumar; Ismail, Ahmad Fauzi; Rajasekar, Rathanasamy
2016-01-01
Management of burn injury is an onerous clinical task since it requires continuous monitoring and extensive usage of specialized facilities. Despite rapid improvizations and investments in burn management, >30% of victims hospitalized each year face severe morbidity and mortality. Excessive loss of body fluids, accumulation of exudate, and the development of septic shock are reported to be the main reasons for morbidity in burn victims. To assist burn wound management, a novel polyurethane (PU)-based bio-nanofibrous dressing loaded with honey (HN) and Carica papaya (PA) fruit extract was fabricated using a one-step electrospinning technique. The developed dressing material had a mean fiber diameter of 190±19.93 nm with pore sizes of 4–50 µm to support effective infiltration of nutrients and gas exchange. The successful blending of HN- and PA-based active biomolecules in PU was inferred through changes in surface chemistry. The blend subsequently increased the wettability (14%) and surface energy (24%) of the novel dressing. Ultimately, the presence of hydrophilic biomolecules and high porosity enhanced the water absorption ability of the PU-HN-PA nanofiber samples to 761.67% from 285.13% in PU. Furthermore, the ability of the bio-nanofibrous dressing to support specific protein adsorption (45%), delay thrombus formation, and reduce hemolysis demonstrated its nontoxic and compatible nature with the host tissues. In summary, the excellent physicochemical and hemocompatible properties of the developed PU-HN-PA dressing exhibit its potential in reducing the clinical complications associated with the treatment of burn injuries. PMID:27621626