Small Drinking Water System Initiative | Drinking Water in New ...
2017-07-06
Reliable, safe, high quality drinking water is essential to sustaining our communities. Approximately 90% of New England's drinking water systems - about 10,000 systems - are small and most use ground water sources.
Small Drinking Water Systems Communication and Outreach ...
As part of our small drinking water systems efforts, this poster highlights several communications and outreach highlights that EPA's Office of Research and Development and Office of Water have been undertaking in collaboration with states and the Association of State Drinking Water Administrators. To share information at EPA's annual small drinking water systems workshop
Sun, F; Chen, J; Tong, Q; Zeng, S
2007-01-01
Management of drinking water safety is changing towards an integrated risk assessment and risk management approach that includes all processes in a water supply system from catchment to consumers. However, given the large number of water supply systems in China and the cost of implementing such a risk assessment procedure, there is a necessity to first conduct a strategic screening analysis at a national level. An integrated methodology of risk assessment and screening analysis is thus proposed to evaluate drinking water safety of a conventional water supply system. The violation probability, indicating drinking water safety, is estimated at different locations of a water supply system in terms of permanganate index, ammonia nitrogen, turbidity, residual chlorine and trihalomethanes. Critical parameters with respect to drinking water safety are then identified, based on which an index system is developed to prioritize conventional water supply systems in implementing a detailed risk assessment procedure. The evaluation results are represented as graphic check matrices for the concerned hazards in drinking water, from which the vulnerability of a conventional water supply system is characterized.
Assessment of Nitrification in Distribution Systems of Waters with Elevated Ammonia Levels
The objective of this work is to monitor ammonia, nitrite, and nitrate in drinking water from the distribution systems of four drinking water utilities in Illinois. A monthly drinking water distribution system water quality monitoring protocol for each water utility in Illinois h...
The release of iron from drinking water distribution systems is a common source of drinking water distribution system consumer complaints. Suspended iron particles result in colored (red) water and metallic tasting water. Iron release results from both physical and chemical mec...
Many water utilities in the US using chloramine as disinfectant treatment in their distribution systems have experienced nitrification episodes, which detrimentally impact the water quality. A chloraminated drinking water distribution system (DWDS) simulator was operated throug...
[Bacteriological quality of drinking water in the City of Merida, Mexico].
Flores-Abuxapqui, J J; Suárez-Hoil, G J; Puc-Franco, M A; Heredia-Navarrete, M R; Vivas-Rosel, M D; Franco-Monsreal, J
1995-01-01
With the aim of knowing the microbiological quality of drinking water in Merida, Yucatan, 383 paired samples of drinking water (two per house) were studied. Three hundred sixty four (95%) city water system samples and 283 (73.89%) tap water samples met the microbiological standards for drinking water. It was concluded that microbiological quality of drinking water from the city water system is satisfactory, except for the water system district Merida III, which has a significant aerobic plate count contamination level (21.7% of the samples). Domestic storage systems preserve water quality, with the exception of district Merida I, which has the highest level of contamination (4.8% of the samples) possibly from sewage water and fecal sources.
Drinking water quality management: a holistic approach.
Rizak, S; Cunliffe, D; Sinclair, M; Vulcano, R; Howard, J; Hrudey, S; Callan, P
2003-01-01
A growing list of water contaminants has led to some water suppliers relying primarily on compliance monitoring as a mechanism for managing drinking water quality. While such monitoring is a necessary part of drinking water quality management, experiences with waterborne disease threats and outbreaks have shown that compliance monitoring for numerical limits is not, in itself, sufficient to guarantee the safety and quality of drinking water supplies. To address these issues, the Australian National Health and Medical Research Council (NHMRC) has developed a Framework for Management of Drinking Water Quality (the Framework) for incorporation in the Australian Drinking Water Guidelines, the primary reference on drinking water quality in Australia. The Framework was developed specifically for drinking water supplies and provides a comprehensive and preventive risk management approach from catchment to consumer. It includes holistic guidance on a range of issues considered good practice for system management. The Framework addresses four key areas: Commitment to Drinking Water Quality Management, System Analysis and System Management, Supporting Requirements, and Review. The Framework represents a significantly enhanced approach to the management and regulation of drinking water quality and offers a flexible and proactive means of optimising drinking water quality and protecting public health. Rather than the primary reliance on compliance monitoring, the Framework emphasises prevention, the importance of risk assessment, maintaining the integrity of water supply systems and application of multiple barriers to assure protection of public health. Development of the Framework was undertaken in collaboration with the water industry, regulators and other stakeholder, and will promote a common and unified approach to drinking water quality management throughout Australia. The Framework has attracted international interest.
Nitrification in Chloraminated Drinking Water Distribution Systems: Factors Affecting Occurrence
Drinking water distribution systems with ammonia present from either naturally occurring ammonia or ammonia addition during chloramination are at risk for nitrification. Nitrification in drinking water distribution systems is undesirable and may result in water quality degradatio...
2013-12-01
Safe Drinking Water Act28 and the Clean Water Act.29 • Potable water : According to Waterworks officials, Guam’s potable water system currently is in...noncompliance with the Safe Drinking Water Act. The unreliable drinking water distribution system has historically resulted in bacterial...Protection Consolidated Grants program, provided Guam with almost $6.8 million in fiscal year 2012 to fund drinking water and wastewater system
Climate change and drinking water production in The Netherlands: a flexible approach.
Ramaker, T A B; Meuleman, A F M; Bernhardi, L; Cirkel, G
2005-01-01
Climate change increases water system dynamics through temperature changes, changes in precipitation patterns, evaporation, water quality and water storage in ice packs. Water system dependent economical stakeholders, such as drinking water companies in The Netherlands, have to cope with consequences of climate change, e.g. floods and water shortages in river systems, upconing brackish ground water, salt water intrusion, increasing peak demands and microbiological activity. In the past decades, however, both water systems and drinking water production have become more and more inflexible; water systems have been heavily regulated and the drinking water supply has grown into an inflexible, but cheap and reliable, system. Flexibility and adaptivity are solutions to overcome climate change related consequences. Flexible adaptive strategies for drinking water production comprise new sources for drinking water production, application of storage concepts in the short term, and a redesign of large centralised systems, including flexible treatment plants, in the long term. Transition to flexible concepts will take decades because investment depreciation periods of assets are long. This implies that long-term strategies within an indicated time path have to be developed. These strategies must be based on thorough knowledge of current assets to seize opportunities for change.
Bacterial community structure in the drinking water microbiome is governed by filtration processes.
Pinto, Ameet J; Xi, Chuanwu; Raskin, Lutgarde
2012-08-21
The bacterial community structure of a drinking water microbiome was characterized over three seasons using 16S rRNA gene based pyrosequencing of samples obtained from source water (a mix of a groundwater and a surface water), different points in a drinking water plant operated to treat this source water, and in the associated drinking water distribution system. Even though the source water was shown to seed the drinking water microbiome, treatment process operations limit the source water's influence on the distribution system bacterial community. Rather, in this plant, filtration by dual media rapid sand filters played a primary role in shaping the distribution system bacterial community over seasonal time scales as the filters harbored a stable bacterial community that seeded the water treatment processes past filtration. Bacterial taxa that colonized the filter and sloughed off in the filter effluent were able to persist in the distribution system despite disinfection of finished water by chloramination and filter backwashing with chloraminated backwash water. Thus, filter colonization presents a possible ecological survival strategy for bacterial communities in drinking water systems, which presents an opportunity to control the drinking water microbiome by manipulating the filter microbial community. Grouping bacterial taxa based on their association with the filter helped to elucidate relationships between the abundance of bacterial groups and water quality parameters and showed that pH was the strongest regulator of the bacterial community in the sampled drinking water system.
Understanding and Controlling iron Release in Distribution Systems
Generation of red-water resulting from the release of iron from drinking water distribution system materials is a major consumer complaint of drinking water systems. The objective of this presentation is to provide a fundamental basis for iron release from drinking water distrib...
West, Danielle M; Mu, Ruipu; Gamagedara, Sanjeewa; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Burken, Joel G; Shi, Honglan
2015-06-01
Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 μg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.
Secondary Drinking Water Standards: Guidance for Nuisance Chemicals
Learn about Secondary Drinking Water Regulations for nuisance chemicals contained in some drinking water. They are established only as guidelines to assist public water systems in managing their drinking water for aesthetic considerations.
MINI PILOT PLANT FOR DRINKING WATER RESEARCH
The Water Supply & Water Resources Division (WSWRD) has constructed 2 mini-pilot plant systems used to conduct drinking water research. These two systems each have 2 parallel trains for comparative research. The mini-pilot plants are small conventional drinking water treatment ...
Nitrification in Chloraminated Drinking Water Distribution Systems - Occurrence
This chapter discusses available information on nitrification occurrence in drinking water chloraminated distribution systems. Chapter 4 provides an introduction to causes and controls for nitrification in chloraminated drinking water systems. Both chapters are intended to serve ...
Meuleman, A F M; Cirkel, G; Zwolsman, G J J
2007-01-01
Climate change increases water system dynamics through temperature changes, changes in precipitation patterns, evaporation, and water quality and water storage in ice packs. Water system dependent economical stakeholders, such as drinking water companies in the Netherlands, have to cope with consequences of climate change, e.g. floods and water shortages in river systems, upcoming of brackish ground water, salt water intrusion, increasing peak demands and microbiological activity due to temperature rise. In the past decades, however, both water systems and drinking water production have become more and more inflexible; water systems have been heavily regulated aiming at maximum security and economic functions and the drinking water supply in the Netherlands has grown into an inflexible, but cheap and reliable, system. At a water catchment scale, flexibility and adaptation are solutions to overcome climate change related consequences. Flexible adaptive strategies for drinking water production comprise new sources for drinking water production, application of storage concepts in the short term, and a redesign of large centralized systems, including flexible treatment plants, in the long term. Transition to flexible concepts will take decades because investment depreciation periods of assets are long. These strategies must be based on thorough knowledge of current assets to seize opportunities for change.
Detection of nitrification events in chloraminated drinking water distribution systems remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification events ...
REGULATED CONTAMINANTS IN DRINKING WATER
Safe drinking water is critical to protecting human health. More than 260 million Americans rely on the safety of tap water provided by water systems that comply with national drinking water standards. EPA's strategy for ensuring safe drinking water includes four key elements, ...
This report reviews current national data for small drinking water treatment systems, regulations pertaining to small systems, current treatment technologies, disposal of wastes, source water protection, security, and monitoring. The document serves as a roadmap for future small...
Tribal Set-Aside Program of the Drinking Water Infrastructure Grant
The Safe Drinking Water Act (SWDA), as amended in 1996, established the Drinking Water State Revolving Fund (DWSRF) to make funds available to drinking water systems to finance infrastructure improvements.
The Sears Kenmore Ultrafilter 500 RO system was tested for removal of bacteria and viruses at NSF International's Drinking Water Treatment Systems Laboratory. EcoWater Systems submitted ten units for testing, which were split into two groups of five. One group received 25 days ...
Report: EPA Lacks Internal Controls to Prevent Misuse of Emergency Drinking Water Facilities
Report #11-P-0001, October 12, 2010. EPA cannot accurately assess the risk of public water systems delivering contaminated drinking water from emergency facilities because of limitations in Safe Drinking Water Information System (SDWIS) data management.
Impact of Hydraulic Well Restoration on Native Bacterial Communities in Drinking Water Wells
Karwautz, Clemens; Lueders, Tillmann
2014-01-01
The microbial monitoring of drinking water production systems is essential to assure water quality and minimize possible risks. However, the comparative impact of microbes from the surrounding aquifer and of those established within drinking water wells on water parameters remains poorly understood. High pressure jetting is a routine method to impede well clogging by fine sediments and also biofilms. In the present study, bacterial communities were investigated in a drinking water production system before, during, and after hydraulic purging. Variations were observed in bacterial communities between different wells of the same production system before maintenance, despite them having practically identical water chemistries. This may have reflected the distinct usage practices of the different wells, and also local aquifer heterogeneity. Hydraulic jetting of one well preferentially purged a subset of the dominating taxa, including lineages related to Diaphorobacter, Nitrospira, Sphingobium, Ralstonia, Alkanindiges, Janthinobacterium, and Pseudomonas spp, suggesting their tendency for growth in well-associated biofilms. Lineages of potential drinking water concern (i.e. Legionellaceae, Pseudomonadaceae, and Acinetobacter spp.) reacted distinctly to hydraulic jetting. Bacterial diversity was markedly reduced in drinking water 2 weeks after the cleaning procedure. The results of the present study provide a better understanding of drinking water wells as a microbial habitat, as well as their role in the microbiology of drinking water systems. PMID:25273229
Impact of hydraulic well restoration on native bacterial communities in drinking water wells.
Karwautz, Clemens; Lueders, Tillmann
2014-01-01
The microbial monitoring of drinking water production systems is essential to assure water quality and minimize possible risks. However, the comparative impact of microbes from the surrounding aquifer and of those established within drinking water wells on water parameters remains poorly understood. High pressure jetting is a routine method to impede well clogging by fine sediments and also biofilms. In the present study, bacterial communities were investigated in a drinking water production system before, during, and after hydraulic purging. Variations were observed in bacterial communities between different wells of the same production system before maintenance, despite them having practically identical water chemistries. This may have reflected the distinct usage practices of the different wells, and also local aquifer heterogeneity. Hydraulic jetting of one well preferentially purged a subset of the dominating taxa, including lineages related to Diaphorobacter, Nitrospira, Sphingobium, Ralstonia, Alkanindiges, Janthinobacterium, and Pseudomonas spp, suggesting their tendency for growth in well-associated biofilms. Lineages of potential drinking water concern (i.e. Legionellaceae, Pseudomonadaceae, and Acinetobacter spp.) reacted distinctly to hydraulic jetting. Bacterial diversity was markedly reduced in drinking water 2 weeks after the cleaning procedure. The results of the present study provide a better understanding of drinking water wells as a microbial habitat, as well as their role in the microbiology of drinking water systems.
An assessment of drinking-water quality post-Haiyan.
Magtibay, Bonifacio; Anarna, Maria Sonabel; Fernando, Arturo
2015-01-01
Access to safe drinking-water is one of the most important public health concerns in an emergency setting. This descriptive study reports on an assessment of water quality in drinking-water supply systems in areas affected by Typhoon Haiyan immediately following and 10 months after the typhoon. Water quality testing and risk assessments of the drinking-water systems were conducted three weeks and 10 months post-Haiyan. Portable test kits were used to determine the presence of Escherichia coli and the level of residual chlorine in water samples. The level of risk was fed back to the water operators for their action. Of the 121 water samples collected three weeks post-Haiyan, 44% were contaminated, while 65% (244/373) of samples were found positive for E. coli 10 months post-Haiyan. For the three components of drinking-water systems - source, storage and distribution - the proportions of contaminated systems were 70%, 67% and 57%, respectively, 10 months after Haiyan. Vulnerability to faecal contamination was attributed to weak water safety programmes in the drinking-water supply systems. Poor water quality can be prevented or reduced by developing and implementing a water safety plan for the systems. This, in turn, will help prevent waterborne disease outbreaks caused by contaminated water post-disaster.
An assessment of drinking-water quality post-Haiyan
Anarna, Maria Sonabel; Fernando, Arturo
2015-01-01
Introduction Access to safe drinking-water is one of the most important public health concerns in an emergency setting. This descriptive study reports on an assessment of water quality in drinking-water supply systems in areas affected by Typhoon Haiyan immediately following and 10 months after the typhoon. Methods Water quality testing and risk assessments of the drinking-water systems were conducted three weeks and 10 months post-Haiyan. Portable test kits were used to determine the presence of Escherichia coli and the level of residual chlorine in water samples. The level of risk was fed back to the water operators for their action. Results Of the 121 water samples collected three weeks post-Haiyan, 44% were contaminated, while 65% (244/373) of samples were found positive for E. coli 10 months post-Haiyan. For the three components of drinking-water systems – source, storage and distribution – the proportions of contaminated systems were 70%, 67% and 57%, respectively, 10 months after Haiyan. Discussion Vulnerability to faecal contamination was attributed to weak water safety programmes in the drinking-water supply systems. Poor water quality can be prevented or reduced by developing and implementing a water safety plan for the systems. This, in turn, will help prevent waterborne disease outbreaks caused by contaminated water post-disaster. PMID:26767136
GEOCHEMISTRY OF SULFUR IN IRON CORROSION SCALES FOUND IN DRINKING WATER DISTRIBUTION SYSTEMS
Iron-sulfur geochemistry is important in many natural and engineered environments, including drinking water systems. In the anaerobic environment beneath scales of corroding iron drinking water distribution system pipes, sulfate reducing bacteria (SRB) produce sulfide from natu...
Flynt, Elizabeth; Dupuy, Aubry; Kennedy, Charles; Bennett, Shanda
2006-09-01
The rapid detection of contaminants in our nation's drinking water has become a top homeland security priority in this time of increased national vigilance. Real-time monitoring of drinking water for deliberate or accidental contamination is key to national security. One method that can be employed for the rapid screening of pollutants in water is solid-phase microextraction (SPME). SPME is a rapid, sensitive, solvent-free system that can be used to screen for contaminants that have been accidentally or intentionally introduced into a water system. A method using SPME has been developed and optimized for the detection of seven organophosphate pesticides in drinking water treatment facility source waters. The method is tested in source waters for drinking water treatment facilities in Mississippi and Alabama. Water is collected from a deepwater well at Stennis Space Center (SSC), MS, the drinking water source for SSC, and from the Converse Reservoir, the main drinking water supply for Mobile, AL. Also tested are samples of water collected from the Mobile Alabama Water and Sewer System drinking water treatment plant prior to chlorination. The method limits of detection for the seven organophosphates were comparable to those described in several Environmental Protection Agency standard methods. They range from 0.25 to 0.94 microg/L.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... revising its approved Public Water System Supervision Program to adopt EPA's National Primary Drinking..., 24th Floor Drinking Water Ground Water Protection Section, 290 Broadway, New York, New York 10007-1866. FOR FURTHER INFORMATION CONTACT: Michael J. Lowy, Drinking Water Ground Water Protection Section, U.S...
Report #17-P-0326, July 18, 2017. The EPA is taking action to improve oversight tools used to determine whether public water systems are monitoring and reporting drinking water quality in accordance with the Safe Drinking Water Act.
The Safe Drinking Water Act's 1996 Amendments broadened the definition of public water systems (PWS) to include systems which serve drinking water to as few as 25 individuals. Implementation of the proposed Ground Water Rule for Pathogens will place an increased burden on utiliti...
75 FR 48329 - Tribal Drinking Water Operator Certification Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-10
... ENVIRONMENTAL PROTECTION AGENCY [FRL-9186-8] Tribal Drinking Water Operator Certification Program... details of EPA's voluntary Tribal Drinking Water Operator Certification Program, effective October 1, 2010. The program enables qualified drinking water operators at public water systems in Indian country to be...
Pinto, Ameet J.; Schroeder, Joanna; Lunn, Mary; Sloan, William
2014-01-01
ABSTRACT Bacterial communities migrate continuously from the drinking water treatment plant through the drinking water distribution system and into our built environment. Understanding bacterial dynamics in the distribution system is critical to ensuring that safe drinking water is being supplied to customers. We present a 15-month survey of bacterial community dynamics in the drinking water system of Ann Arbor, MI. By sampling the water leaving the treatment plant and at nine points in the distribution system, we show that the bacterial community spatial dynamics of distance decay and dispersivity conform to the layout of the drinking water distribution system. However, the patterns in spatial dynamics were weaker than those for the temporal trends, which exhibited seasonal cycling correlating with temperature and source water use patterns and also demonstrated reproducibility on an annual time scale. The temporal trends were driven by two seasonal bacterial clusters consisting of multiple taxa with different networks of association within the larger drinking water bacterial community. Finally, we show that the Ann Arbor data set robustly conforms to previously described interspecific occupancy abundance models that link the relative abundance of a taxon to the frequency of its detection. Relying on these insights, we propose a predictive framework for microbial management in drinking water systems. Further, we recommend that long-term microbial observatories that collect high-resolution, spatially distributed, multiyear time series of community composition and environmental variables be established to enable the development and testing of the predictive framework. PMID:24865557
Völker, S; Schreiber, C; Müller, H; Zacharias, N; Kistemann, T
2017-05-01
After the amendment of the Drinking Water Ordinance in 2011, the requirements for the hygienic-microbiological monitoring of drinking water installations have increased significantly. In the BMBF-funded project "Biofilm Management" (2010-2014), we examined the extent to which established sampling strategies in practice can uncover drinking water plumbing systems systemically colonized with Legionella. Moreover, we investigated additional parameters that might be suitable for detecting systemic contaminations. We subjected the drinking water plumbing systems of 8 buildings with known microbial contamination (Legionella) to an intensive hygienic-microbiological sampling with high spatial and temporal resolution. A total of 626 drinking hot water samples were analyzed with classical culture-based methods. In addition, comprehensive hygienic observations were conducted in each building and qualitative interviews with operators and users were applied. Collected tap-specific parameters were quantitatively analyzed by means of sensitivity and accuracy calculations. The systemic presence of Legionella in drinking water plumbing systems has a high spatial and temporal variability. Established sampling strategies were only partially suitable to detect long-term Legionella contaminations in practice. In particular, the sampling of hot water at the calorifier and circulation re-entrance showed little significance in terms of contamination events. To detect the systemic presence of Legionella,the parameters stagnation (qualitatively assessed) and temperature (compliance with the 5K-rule) showed better results. © Georg Thieme Verlag KG Stuttgart · New York.
White Sands Missile Range 2011 Drinking Water Quality Report
2012-01-01
This Annual Drinking Water Quality Report, or the Consumer Confi dence Report, is required by the Safe Drinking Water Act (SDWA). The SDWA ensures...public drinking water systems meet national standards for the protection of your health. This report provides details about where your water comes...NMED). WSMR tap water meets all EPA and NMED drinking water standards. What is This Water Quality Report? Este informe contiene informacion importante
30 CFR 71.602 - Drinking water; distribution.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Drinking water; distribution. 71.602 Section 71... Drinking Water § 71.602 Drinking water; distribution. (a) Water shall be piped or transported in sanitary containers. Water systems and appurtenances thereto shall be constructed and maintained in accordance with...
30 CFR 71.602 - Drinking water; distribution.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drinking water; distribution. 71.602 Section 71... Drinking Water § 71.602 Drinking water; distribution. (a) Water shall be piped or transported in sanitary containers. Water systems and appurtenances thereto shall be constructed and maintained in accordance with...
30 CFR 71.602 - Drinking water; distribution.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Drinking water; distribution. 71.602 Section 71... Drinking Water § 71.602 Drinking water; distribution. (a) Water shall be piped or transported in sanitary containers. Water systems and appurtenances thereto shall be constructed and maintained in accordance with...
30 CFR 71.602 - Drinking water; distribution.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Drinking water; distribution. 71.602 Section 71... Drinking Water § 71.602 Drinking water; distribution. (a) Water shall be piped or transported in sanitary containers. Water systems and appurtenances thereto shall be constructed and maintained in accordance with...
30 CFR 71.602 - Drinking water; distribution.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Drinking water; distribution. 71.602 Section 71... Drinking Water § 71.602 Drinking water; distribution. (a) Water shall be piped or transported in sanitary containers. Water systems and appurtenances thereto shall be constructed and maintained in accordance with...
Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...
Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...
According to FY2003 statistics compiled by the Office of Ground Water and Drinking Water, the U.S. regulates about 160,000 small drinking water systems that impact close to 70 million people. Small systems (serving transient and non-transient populations of 10,000 people or less...
78 FR 47697 - Public Water System Supervision Program Revision for the State of Louisiana
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-06
... Public Water System Supervision Program. Louisiana has adopted three EPA drinking water rules, namely the..., Baton Rouge, LA 70821; and United States Environmental Protection Agency, Region 6, Drinking Water... Camacho, EPA Region 6, Drinking Water Section at the Dallas address given above, or by telephone at (214...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... System Supervision (PWSS) programs to meet the requirements of the Safe Drinking Water Act (SDWA). The State of Rhode Island has adopted drinking water regulations for the Arsenic Rule (66 FR 6976... adopted drinking water regulations for the Interim Enhanced Surface Water Treatment Rule (63 FR 69477...
Baum, Rachel; Amjad, Urooj; Luh, Jeanne; Bartram, Jamie
2015-11-01
National and sub-national governments develop and enforce regulations to ensure the delivery of safe drinking water in the United States (US) and countries worldwide. However, periodic contamination events, waterborne endemic illness and outbreaks of waterborne disease still occur, illustrating that delivery of safe drinking water is not guaranteed. In this study, we examined the potential added value of a preventive risk management approach, specifically, water safety plans (WSPs), in the US in order to improve drinking water quality. We undertook a comparative analysis between US drinking water regulations and WSP steps to analyze the similarities and differences between them, and identify how WSPs might complement drinking water regulations in the US. Findings show that US drinking water regulations and WSP steps were aligned in the areas of describing the water supply system and defining monitoring and controls. However, gaps exist between US drinking water regulations and WSPs in the areas of team procedures and training, internal risk assessment and prioritization, and management procedures and plans. The study contributes to understanding both required and voluntary drinking water management practices in the US and how implementing water safety plans could benefit water systems to improve drinking water quality and human health. Copyright © 2015 Elsevier GmbH. All rights reserved.
Scheili, A; Rodriguez, Manuel J; Sadiq, R
2015-11-01
The aim of this study was to produce a drinking water assessment tool for operators of small distribution systems. A drinking water quality index (DWQI) was developed and applied to small systems based on the water quality index of the Canadian Council of Ministers of Environment. The drinking water quality index was adapted to specific needs by creating four drinking water quality scenarios. First, the temporal and spatial dimensions of drinking water quality variability were taken into account. The DWQI was designed to express global drinking water quality according to different monitoring frequencies. Daily, monthly, and seasonal assessment was also considered. With the data made available, it was possible to use the index as a spatial monitoring tool and express water quality in different points in the distribution system. Moreover, adjustments were made to prioritize the type of contaminant to monitor. For instance, monitoring contaminants with acute health effects led to a scenario based on daily measures, including easily accessible and affordable water quality parameters. On the other hand, contaminants with chronic effects, especially disinfection by-products, were considered in a seasonal monitoring scenario where disinfection by-product reference values were redefined according to their seasonal variability. A sensitivity analysis was also carried out to validate the index. Globally, the DWQI developed is adapted to the needs of small systems. In fact, expressing drinking water quality using the DWQI contributes to the identification of problematic periods and segments in the distribution system. Further work may include this index in the development of a customized decision-making tool for small-system operators and managers.
40 CFR 141.700 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Treatment for Cryptosporidium General... drinking water regulations. The regulations in this subpart establish or extend treatment technique... requirements of this subpart for filtered systems apply to systems required by National Primary Drinking Water...
Heijnen, Leo; van der Kooij, Dick
2013-01-01
Studies have shown that certain opportunistic pathogenic species of nontuberculous mycobacteria (NTM) can be present in distributed drinking water. However, detailed information about NTM population composition in drinking water is lacking. Therefore, NTM communities in unchlorinated drinking water from the distribution system of five treatment plants in the Netherlands were characterized using 454 pyrosequencing of the hsp65 gene. Results showed high diversities in unchlorinated drinking water, with up to 28 different NTM operational taxonomic units (OTUs) in a single sample. Each drinking water sample had a unique NTM community, and most (81.1%) OTUs were observed only once. One OTU was observed in 14 of 16 drinking water samples, indicating that this NTM species is well adapted to unchlorinated drinking water conditions. A clear influence of season, source type (groundwater, surface water), easily assimilable organic carbon (AOC) concentration, biofilm formation rate, and active biomass in treated water on the establishment of an NTM community in drinking water was not observed. Apparently, local conditions are more important for the development of a specific NTM community in the drinking water distribution system. A low (4.2%) number of hsp65 gene sequences showed more than 97% similarity to sequences of the opportunistic pathogens M. avium, M. genavense, and M. gordonae. However, most (95.8%) NTM hsp65 gene sequences were related to not-yet-described NTM species that have not been linked to disease, indicating that most NTM species in unchlorinated drinking water from distribution systems in the Netherlands have a low public health significance. PMID:23913420
van der Wielen, Paul W J J; Heijnen, Leo; van der Kooij, Dick
2013-10-01
Studies have shown that certain opportunistic pathogenic species of nontuberculous mycobacteria (NTM) can be present in distributed drinking water. However, detailed information about NTM population composition in drinking water is lacking. Therefore, NTM communities in unchlorinated drinking water from the distribution system of five treatment plants in the Netherlands were characterized using 454 pyrosequencing of the hsp65 gene. Results showed high diversities in unchlorinated drinking water, with up to 28 different NTM operational taxonomic units (OTUs) in a single sample. Each drinking water sample had a unique NTM community, and most (81.1%) OTUs were observed only once. One OTU was observed in 14 of 16 drinking water samples, indicating that this NTM species is well adapted to unchlorinated drinking water conditions. A clear influence of season, source type (groundwater, surface water), easily assimilable organic carbon (AOC) concentration, biofilm formation rate, and active biomass in treated water on the establishment of an NTM community in drinking water was not observed. Apparently, local conditions are more important for the development of a specific NTM community in the drinking water distribution system. A low (4.2%) number of hsp65 gene sequences showed more than 97% similarity to sequences of the opportunistic pathogens M. avium, M. genavense, and M. gordonae. However, most (95.8%) NTM hsp65 gene sequences were related to not-yet-described NTM species that have not been linked to disease, indicating that most NTM species in unchlorinated drinking water from distribution systems in the Netherlands have a low public health significance.
[Microorganisms surviving in drinking water systems and related problems].
Aulicino, F A; Pastoni, F
2004-01-01
Drinking water in distribution systems may show abnormal values of some parameters, such as turbidity, and may support particular phenomena, such as bacterial regrowth or presence of Viable Not Culturable (VNC) bacteria. Turbidity can provide shelter for opportunistic microorganisms and pathogens. The Milwaukee outbreak (400,000 people) is one example of waterborne disease caused by the presence of pathogens (Cryptosporidium) in drinking water characterized by high and intermittent levels of turbidity. Bacterial regrowth in drinking water distribution systems may cause high increments of microorganisms such as heterotrophic bacteria, coliforms and pathogens. Microorganisms isolated from biofilm including Pseudomonas, Aeromonas, Legionella may have a significant health hazard especially in hospital areas. The presence of VNC bacteria in drinking water may represent a problem for their discussed role in infectious diseases, but also for the possibility of a considerable underestimation of true microbial concentrations in drinking waters. To study this kind of problems is necessary to apply suitable methods for drinking water analyses.
Gibs, J.; Stackelberg, P.E.; Furlong, E.T.; Meyer, M.; Zaugg, S.D.; Lippincott, R.L.
2007-01-01
Ninety eight pharmaceuticals and other organic compounds (POOCs) that were amended to samples of chlorinated drinking-water were extracted and analyzed 1, 3, 6, 8, and 10 days after amendment to determine whether the total chlorine residual reacted with the amended POOCs in drinking water in a time frame similar to the residence time of drinking water in a water distribution system. Results indicated that if all 98 were present in the finished drinking water from a drinking-water treatment plant using free chlorine at 1.2??mg/L as the distribution system disinfectant residual, 52 POOCs would be present in the drinking water after 10??days at approximately the same concentration as in the newly finished drinking water. Concentrations of 16 POOCs would be reduced by 32% to 92%, and 22 POOCs would react completely with residual chlorine within 24??h. Thus, the presence of free chlorine residual is an effective means for transforming some POOCs during distribution. ?? 2006 Elsevier B.V. All rights reserved.
Gibs, Jacob; Stackelberg, Paul E; Furlong, Edward T; Meyer, Michael; Zaugg, Steven D; Lippincott, Robert Lee
2007-02-01
Ninety eight pharmaceuticals and other organic compounds (POOCs) that were amended to samples of chlorinated drinking-water were extracted and analyzed 1, 3, 6, 8, and 10 days after amendment to determine whether the total chlorine residual reacted with the amended POOCs in drinking water in a time frame similar to the residence time of drinking water in a water distribution system. Results indicated that if all 98 were present in the finished drinking water from a drinking-water treatment plant using free chlorine at 1.2 mg/L as the distribution system disinfectant residual, 52 POOCs would be present in the drinking water after 10 days at approximately the same concentration as in the newly finished drinking water. Concentrations of 16 POOCs would be reduced by 32% to 92%, and 22 POOCs would react completely with residual chlorine within 24 h. Thus, the presence of free chlorine residual is an effective means for transforming some POOCs during distribution.
The Watts Premier WP-4V four-stage POU RO system was tested for removal of bacteria and viruses at NSF’s Drinking Water Treatment Systems Laboratory. Five systems were challenged with the bacteriophage viruses fr and MS2, and the bacteria Brevundimonas diminutaEM. The ...
76 FR 72703 - Meeting of the National Drinking Water Advisory Council-Notice of Public Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-25
... small water systems and efforts underway to address nutrient pollution of drinking water supplies. The... ENVIRONMENTAL PROTECTION AGENCY [FRL-9496-4] Meeting of the National Drinking Water Advisory... meeting. SUMMARY: Notice is hereby given of a meeting of the National Drinking Water Advisory Council...
The Pall/Kinetico Purefecta™ POU drinking water treatment system was tested for removal of aldicarb, benzene, cadmium, carbofuran, cesium, chloroform, dichlorvos, dicrotophos, fenamiphos, mercury, mevinphos, oxamyl, strontium, and strychnine. The Purefecta™ employs several compon...
Small Drinking Water Systems Communication and Outreach Highlights
As part of our small drinking water systems efforts, this poster highlights several communications and outreach highlights that EPA's Office of Research and Development and Office of Water have been undertaking in collaboration with states and the Association of State Drinking Wa...
POINT-OF-ENTRY DRINKING WATER TREATMENT SYSTEMS FOR SUPERFUND APPLICATIONS
The U.S. Environmental Protection AGency (EPA) and State Superfund agencies need a technical assistance manualto assist their personnel in the selection of an effective drinking water treatment system for aindividualhouseholds in areas whre the drinking water has been adversely a...
There are approximately 160,000 small community and non-community drinking water treatment systems in the United States. According to recent estimates, small systems contribute to 94% of the Safe Drinking Water Act violations annually. A majority of these are for microbiological ...
There are approximately 160,000 small community and non-community drinking water treatment systems in the United States. According to recent estimates, small systems contribute to 94% of the Safe Drinking Water Act violations annually. A majority of these are for microbiological...
Smart Water: Energy-Water Optimization in Drinking Water Systems
This project aims to develop and commercialize a Smart Water Platform – Sensor-based Data-driven Energy-Water Optimization technology in drinking water systems. The key technological advances rely on cross-platform data acquisition and management system, model-based real-time sys...
van der Lugt, Wilco; Euser, Sjoerd M; Bruin, Jacob P; Den Boer, Jeroen W; Walker, Jimmy T; Crespi, Sebastian
2017-11-01
Legionella continues to be a problem in water systems. This study investigated the influence of different shower mixer faucets, and the influence of the presence of cast iron rust from a drinking water system on the growth of Legionella. The research is conducted using a model of a household containing four drinking water systems. All four systems, which contained standard plumbing components including copper pipes and a water heater, were filled with unchlorinated drinking water. Furthermore, all systems had three different shower faucets: (A) a stainless-steel faucet, (B) a brass-ceramic faucet, and (C) a brass thermostatic faucet. System 1 was solely filled with drinking water. System 2 was filled with drinking water, and cast iron rust. System 3 was contaminated with Legionella, and system 4 was contaminated with a Legionella, and cast iron rust. During a period of 34 months, 450 cold water samples were taken from 15 sample points of the four drinking water systems, and tested for Legionella according to the Dutch Standard (NEN 6265). In system 4, with added cast iron rust, the stainless-steel mixer faucet (A) had the highest concentration of Legionella at >4.3log10CFU/l (>20,000CFU/l) and was positive in 46.4% of samples. In contrast, the stainless-steel mixer faucet (A) of system 3 without cast iron rust showed 14.3% positive samples with a maximum concentration of 3.9log10CFU/l (7600CFU/l) Legionella. Additionally, both contaminated systems (3 and 4), with the brass thermostatic faucet (C), tested positive for Legionella. System 3 in 85.7% of the samples, with a maximum concentration of 4.38log10CFU/l (24,200CFU/l), and system 4 in 64.3% of the samples with a maximum concentration of 4.13log10CFU/l (13.400CFU/l). These results suggest that both the type of faucet used in a drinking water system and the presence or absence of cast iron rust influence the growth of Legionella. Copyright © 2017 Elsevier GmbH. All rights reserved.
Background: Current evidence suggests that drinking water, soil, and produce are potential sources of Mycobacterium avium infections, a pathogen not known to be transmitted person-to-person.
Methods: We sampled water during 2000-2002 from a large municipal drinking water ...
Microbial Community Profile of a Lead Service Line Removed from a Drinking Water Distribution System
A corroded lead water pipe was removed from a drinking water distribution system and the microbial community was profiled using 16S rDNA techniques. This is the first report of the characterization of biofilm on a surface of a corroded lead drinking water pipe. The majority of ...
Drinking Water Maximum Contaminant Levels (MCLs)
National Primary Drinking Water Regulations (NPDWRs or primary standards) are legally enforceable standards that apply to public water systems. Primary standards protect public health by limiting the levels of contaminants in drinking water.
ETV COLLABORATIVE EVALUATIONS OF MARKET-READY TECHNOLOGIES FOR ARSENIC REMOVAL IN DRINKING WATER
How well do some commercially marketed package treatment systems perform to reduce arsenic from drinking water supplies? The Environmental Technology Verification (ETV) Drinking Water Systems (DWS) Center is a partnership between the U.S. Environmental Protection Agency (U.S. EPA...
SEMINAR PUBLICATION: CONTROL OF LEAD AND COPPER IN DRINKING WATER
This publication presents subjects relating to the control of lead and copper in drinking water systems. t is of interest to system owners, operators, managers, and local decision makers, such as town officials, regarding drinking water treatment requirements and the treatment te...
GIS-based analysis of drinking-water supply structures: a module for microbial risk assessment.
Kistemann, T; Herbst, S; Dangendorf, F; Exner, M
2001-05-01
Water-related infections constitute an important health impact world-wide. A set of tools serving for Microbial Risk Assessment (MRA) of waterborne diseases should comprise the entire drinking-water management system and take into account the Hazard Analysis and Critical Control Point (HACCP) concept which provides specific Critical Control Points (CCPs) reflecting each step of drinking-water provision. A Geographical Information System (GIS) study concerning water-supply structure (WSS) was conducted in the Rhein-Berg District (North Rhine-Westphalia, Germany). As a result, suitability of the existing water databases HYGRIS (hydrological basis geo-information system) and TEIS (drinking-water recording and information system) for the development of a WSS-GIS module could be demonstrated. Spatial patterns within the integrated raw and drinking-water data can easily be uncovered by GIS-specific options. The application of WSS-GIS allows a rapid visualization and analysis of drinking-water supply structure and offers huge advantages concerning microbial monitoring of raw and drinking water as well as recognition and investigation of incidents and outbreaks. Increasing requests regarding health protection and health reporting, demands for a better outbreak management and water-related health impacts of global climate change are major challenges of future water management to be tackled with methods including spatial analysis. GIS is assumed to be a very useful tool to meet these requirements.
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in...
Drinking Water State Revolving Fund (DWSRF)
This website provides information on financial assistance to water systems needing capitalization grants and/or technical assistance to improve the quality of drinking water and for the delivery of safe drinking water to consumers.
Brunkard, Joan M; Ailes, Elizabeth; Roberts, Virginia A; Hill, Vincent; Hilborn, Elizabeth D; Craun, Gunther F; Rajasingham, Anu; Kahler, Amy; Garrison, Laurel; Hicks, Lauri; Carpenter, Joe; Wade, Timothy J; Beach, Michael J; Yoder Msw, Jonathan S
2011-09-23
Since 1971, CDC, the Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have collaborated on the Waterborne Disease and Outbreak Surveillance System (WBDOSS) for collecting and reporting data related to occurrences and causes of waterborne disease outbreaks associated with drinking water. This surveillance system is the primary source of data concerning the scope and health effects of waterborne disease outbreaks in the United States. Data presented summarize 48 outbreaks that occurred during January 2007--December 2008 and 70 previously unreported outbreaks. WBDOSS includes data on outbreaks associated with drinking water, recreational water, water not intended for drinking (WNID) (excluding recreational water), and water use of unknown intent (WUI). Public health agencies in the states, U.S. territories, localities, and Freely Associated States are primarily responsible for detecting and investigating outbreaks and reporting them voluntarily to CDC by a standard form. Only data on outbreaks associated with drinking water, WNID (excluding recreational water), and WUI are summarized in this report. Outbreaks associated with recreational water are reported separately. A total of 24 states and Puerto Rico reported 48 outbreaks that occurred during 2007--2008. Of these 48 outbreaks, 36 were associated with drinking water, eight with WNID, and four with WUI. The 36 drinking water--associated outbreaks caused illness among at least 4,128 persons and were linked to three deaths. Etiologic agents were identified in 32 (88.9%) of the 36 drinking water--associated outbreaks; 21 (58.3%) outbreaks were associated with bacteria, five (13.9%) with viruses, three (8.3%) with parasites, one (2.8%) with a chemical, one (2.8%) with both bacteria and viruses, and one (2.8%) with both bacteria and parasites. Four outbreaks (11.1%) had unidentified etiologies. Of the 36 drinking water--associated outbreaks, 22 (61.1%) were outbreaks of acute gastrointestinal illness (AGI), 12 (33.3%) were outbreaks of acute respiratory illness (ARI), one (2.8%) was an outbreak associated with skin irritation, and one (2.8%) was an outbreak of hepatitis. All outbreaks of ARI were caused by Legionella spp. A total of 37 deficiencies were identified in the 36 outbreaks associated with drinking water. Of the 37 deficiencies, 22 (59.5%) involved contamination at or in the source water, treatment facility, or distribution system; 13 (35.1%) occurred at points not under the jurisdiction of a water utility; and two (5.4%) had unknown/insufficient deficiency information. Among the 21 outbreaks associated with source water, treatment, or distribution system deficiencies, 13 (61.9%) were associated with untreated ground water, six (28.6%) with treatment deficiencies, one (4.8%) with a distribution system deficiency, and one (4.8%) with both a treatment and a distribution system deficiency. No outbreaks were associated with untreated surface water. Of the 21 outbreaks, 16 (76.2%) occurred in public water systems (drinking water systems under the jurisdiction of EPA regulations and water utility management), and five (23.8%) outbreaks occurred in individual systems (all of which were associated with untreated ground water). Among the 13 outbreaks with deficiencies not under the jurisdiction of a water system, 12 (92.3%) were associated with the growth of Legionella spp. in the drinking water system, and one (7.7%) was associated with a plumbing deficiency. In the two outbreaks with unknown deficiencies, one was associated with a public water supply, and the other was associated with commercially bottled water. The 70 previously unreported outbreaks included 69 Legionella outbreaks during 1973--2000 that were not reportable previously to WBDOSS and one previously unreported outbreak from 2002. More than half of the drinking water--associated outbreaks reported during the 2007--2008 surveillance period were associated with untreated or inadequately treated ground water, indicating that contamination of ground water remains a public health problem. The majority of these outbreaks occurred in public water systems that are subject to EPA's new Ground Water Rule (GWR), which requires the majority of community water systems to complete initial sanitary surveys by 2012. The GWR focuses on identification of deficiencies, protection of wells and springs from contamination, and providing disinfection when necessary to protect against bacterial and viral agents. In addition, several drinking water--associated outbreaks that were related to contaminated ground water appeared to occur in systems that were potentially under the influence of surface water. Future efforts to collect data systematically on contributing factors associated with drinking water outbreaks and deficiencies, including identification of ground water under the direct influence of surface water and the criteria used for their classification, would be useful to better assess risks associated with ground water. During 2007--2008, Legionella was the most frequently reported etiology among drinking water--associated outbreaks, following the pattern observed since it was first included in WBDOSS in 2001. However, six (50%) of the 12 drinking water--associated Legionella outbreaks were reported from one state, highlighting the substantial variance in outbreak detection and reporting across states and territories. The addition of published and CDC-investigated legionellosis outbreaks to the WBDOSS database clarifies that Legionella is not a new public health issue. During 2009, Legionella was added to EPA's Contaminant Candidate List for the first time. CDC and EPA use WBDOSS surveillance data to identify the types of etiologic agents, deficiencies, water systems, and sources associated with waterborne disease outbreaks and to evaluate the adequacy of current technologies and practices for providing safe drinking water. Surveillance data also are used to establish research priorities, which can lead to improved water quality regulation development. Approximately two thirds of the outbreaks associated with untreated ground water reported during the 2007--2008 surveillance period occurred in public water systems. When fully implemented, the GWR that was promulgated in 2006 is expected to result in decreases in ground water outbreaks, similar to the decreases observed in surface water outbreaks after enactment of the Surface Water Treatment Rule in 1974 and its subsequent amendments. One third of drinking water--associated outbreaks occurred in building premise plumbing systems outside the jurisdiction of water utility management and EPA regulations; Legionella spp. accounted for >90% of these outbreaks, indicating that greater attention is needed to reduce the risk for legionellosis in building plumbing systems. Finally, a large communitywide drinking water outbreak occurred in 2008 in a public water system associated with a distribution system deficiency, underscoring the importance of maintaining and upgrading drinking water distribution system infrastructure to provide safe water and protect public health.
The Watts Premier M-2400 POE RO Drinking Water Treatment System was tested at the NSF Drinking Water Treatment Systems Laboratory for removal of the viruses fr and MS2, the bacteria Brevundimonas diminuta, and chemicals aldicarb, benzene, cadmium, carbofuran, cesium, chl...
Report #2006-P-00014, March 7, 2006. The Louisiana Department of Health and Hospitals and drinking water systems operators provided the public with timely and accurate information about the safety and proper treatment of drinking water.
Evaluating the fundamental corrosion and passivation of metallic copper used in drinking water distribution materials is important in understanding the overall mechanism of the corrosion process. Copper pipes are widely used for drinking water distribution systems and although it...
ASSESSING AND PREVENTING THE SPREAD OF CONTAMINANTS IN A DRINKING WATER DISTRIBUTION SYSTEM
Remote monitoring data, field studies, and the modeling software ? EPANET, can be used by drinking water utilities and consulting engineers to predict flow dynamics and information on the spatial distribution and concentration of contaminants in a drinking water system. A field ...
Drinking cholera: salinity levels and palatability of drinking water in coastal Bangladesh.
Grant, Stephen Lawrence; Tamason, Charlotte Crim; Hoque, Bilqis Amin; Jensen, Peter Kjaer Mackie
2015-04-01
To measure the salinity levels of common water sources in coastal Bangladesh and explore perceptions of water palatability among the local population to investigate the plausibility of linking cholera outbreaks in Bangladesh with ingestion of saline-rich cholera-infected river water. Hundred participants took part in a taste-testing experiment of water with varying levels of salinity. Salinity measurements were taken of both drinking and non-drinking water sources. Informal group discussions were conducted to gain an in-depth understanding of water sources and water uses. Salinity levels of non-drinking water sources suggest that the conditions for Vibrio cholerae survival exist 7-8 days within the local aquatic environment. However, 96% of participants in the taste-testing experiment reported that they would never drink water with salinity levels that would be conducive to V. cholerae survival. Furthermore, salinity levels of participant's drinking water sources were all well below the levels required for optimal survival of V. cholerae. Respondents explained that they preferred less salty and more aesthetically pleasing drinking water. Theoretically, V. cholerae can survive in the river systems in Bangladesh; however, water sources which have been contaminated with river water are avoided as potential drinking water sources. Furthermore, there are no physical connecting points between the river system and drinking water sources among the study population, indicating that the primary driver for cholera cases in Bangladesh is likely not through the contamination of saline-rich river water into drinking water sources. © 2015 John Wiley & Sons Ltd.
Pilot-scale demonstration of phytofiltration for treatment of arsenic in New Mexico drinking water.
Elless, Mark P; Poynton, Charissa Y; Willms, Cari A; Doyle, Mike P; Lopez, Alisa C; Sokkary, Dale A; Ferguson, Bruce W; Blaylock, Michael J
2005-10-01
Arsenic contamination of drinking water poses serious health risks to millions of people worldwide. To reduce such risks, the United States Environmental Protection Agency recently lowered the Maximum Contaminant Level for arsenic in drinking water from 50 to 10 microgL(-1). The majority of water systems requiring compliance are small systems that serve less than 10,000 people. Current technologies used to clean arsenic-contaminated water have significant drawbacks, particularly for small treatment systems. In this pilot-scale demonstration, we investigated the use of arsenic-hyperaccumulating ferns to remove arsenic from drinking water using a continuous flow phytofiltration system. Over the course of a 3-month demonstration period, the system consistently produced water having an arsenic concentration less than the detection limit of 2 microgL(-1), at flow rates as high as 1900 L day(-1) for a total treated water volume of approximately 60,000 L. Our results demonstrate that phytofiltration provides the basis for a solar-powered hydroponic technique to enable small-scale cleanup of arsenic-contaminated drinking water.
Al-Herrawy, Ahmad Z; Gad, Mahmoud A
2017-01-01
The aim of this study was to compare between slow and rapid sand filters for the removal of free-living amoebae during drinking water treatment production. Overall, 48 water samples were collected from two drinking water treatment plants having two different filtration systems (slow and rapid sand filters) and from inlet and outlet of each plant. Water samples were collected from Fayoum Drinking Water and Wastewater Holding Company, Egypt, during the year 2015. They were processed for detection of FLAs using non-nutrient agar (NNA). The isolates of FLAs were microscopically identified to the genus level based on the morphologic criteria and molecularly confirmed by the aid of PCR using genus-specific primers. The percentage of removal for FLAs through different treatment processes reached its highest rate in the station using slow sand filters (83%), while the removal by rapid sand filter system was 71.4%. Statistically, there was no significant difference ( P =0.55) for the removal of FLAs between the two different drinking water treatment systems. Statistically, seasons had no significant effect on the prevalence of FLAs in the two different drinking water treatment plants. Morphological identification of the isolated FLAs showed the presence of 3 genera namely Acanthamoeba , Naegleria , and Vermamoeba ( Hartmannella ) confirmed by PCR. The appearance of FLAs especially pathogenic amoebae in completely treated drinking water may cause potential health threat although there is no statistical difference between the two examined drinking water filtration systems.
Basic Information about Your Drinking Water
The United States enjoys one of the world's most reliable and safest supplies of drinking water. Congress passed the Safe Drinking Water Act (SDWA) in 1974 to protect public health, including by regulating public water systems.
40 CFR 141.808 - Audits and inspections.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... delivery of safe drinking water. ...
The passage of the U.S. Safe Drinking Water Act (SDWA) in 1974 has had a major impact on the way water is treated and delivered in the U.S. The Act established national drinking water regulations for more than 170,000 public drinking water systems serving over 250 million people ...
Hanf, R William; Kelly, Lynn M
2005-03-01
Drinking water is supplied to most U.S. Department of Energy (DOE) facilities on the Hanford Site by DOE-owned, contractor-operated pumping and distribution systems. Water is primarily obtained from the Columbia River, but some facilities use water from on-site groundwater wells. Because of the large amount of radioactive and chemical waste produced, stored, and disposed of at Hanford, some people are concerned that waste materials are contaminating on-site drinking-water supplies. This paper describes the drinking-water facilities and treatment requirements on the Hanford Site and summarizes radiological and non-radiological water quality data obtained from water samples collected from each drinking-water system in use during 2001 and 2002. Monitoring data show that Hanford-produced radionuclides are measurable in some drinking-water samples. The only non-radiological contaminants detected either were by-products of the chlorination process or came from off-site agricultural activities. Contaminant level values were, in all cases, below state and federal drinking-water limits. This information will provide assurance to current employees and future site developers that drinking water on the Hanford Site is safe for public consumption.
How to Identify Lead Free Certification Marks for Drinking Water System & Plumbing Products
The Reduction of Lead in Drinking Water Act went into effect on January 4, 2014. The Act has reduced the lead content allowed in water system and plumbing products by changing the definition of lead free in Section 1417 of the Safe Drinking Water Act (SDWA) from not more than 8% ...
“Colored water” resulting from suspended iron particles is a common drinking water consumer complaint which is largely impacted by water chemistry. A bench scale study, performed on a 90 year-old corroded cast-iron pipe section removed from a drinking water distribution system, w...
DeFelice, Nicholas B; Johnston, Jill E; Gibson, Jacqueline MacDonald
2015-08-18
The magnitude and spatial variability of acute gastrointestinal illness (AGI) cases attributable to microbial contamination of U.S. community drinking water systems are not well characterized. We compared three approaches (drinking water attributable risk, quantitative microbial risk assessment, and population intervention model) to estimate the annual number of emergency department visits for AGI attributable to microorganisms in North Carolina community water systems. All three methods used 2007-2013 water monitoring and emergency department data obtained from state agencies. The drinking water attributable risk method, which was the basis for previous U.S. Environmental Protection Agency national risk assessments, estimated that 7.9% of annual emergency department visits for AGI are attributable to microbial contamination of community water systems. However, the other methods' estimates were more than 2 orders of magnitude lower, each attributing 0.047% of annual emergency department visits for AGI to community water system contamination. The differences in results between the drinking water attributable risk method, which has been the main basis for previous national risk estimates, and the other two approaches highlight the need to improve methods for estimating endemic waterborne disease risks, in order to prioritize investments to improve community drinking water systems.
Drinking Water Distribution Systems
Learn about an overview of drinking water distribution systems, the factors that degrade water quality in the distribution system, assessments of risk, future research about these risks, and how to reduce cross-connection control risk.
MEETING THE REQUIREMENTS OF THE U.S. SAFE DRINKING WATER ACT: THE ROLE OF TECHNOLOGY
The passage of the U.S. Safe Drinking Water Act (SDWA) in 1974 has had a major impact on the way water is treated and delivered in the United States. The Act established national drinking water regulations for more than 170,000 public drinking water systems serving over 250 mill...
A survey of ²²²Rn in drinking water in Mexico City.
Vázquez-López, C; Zendejas-Leal, B E; Golzarri, J I; Espinosa, G
2011-05-01
In Mexico City there are more than 22 millions of inhabitants (10 in the metropolitan area and 12 in the suburban zone) exposed to drinking water. The local epidemiological authorities recognised that exposure to radon contaminated drinking water is a potential health hazard, as has been considered worldwide. The United States Environmental Protection Agency has proposed a limit of 11.1 Bq l(-1) for the radon level in drinking water. In Mexico a maximum contamination level of radon in drinking water has not yet even considered. In this work, a (222)Rn study of drinking water in Mexico City has revealed a range of concentrations from background level to 3.8 Bq l(-1). (222)Rn was calculated using a portable degassing system (AquaKIT) associated with an AlphaGUARD measuring system. Samples from 70 wells of the water system of the south of the Valley Basin of Mexico City and from houses of some other political administrative divisions of Mexico City were taken.
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... calendar quarter of initial operation of the aircraft. (e) Any changes to the aircraft water system... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Aircraft water system operations and...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2011 CFR
2011-07-01
... calendar quarter of initial operation of the aircraft. (e) Any changes to the aircraft water system... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Aircraft water system operations and...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule...
[Pay attention to the human health risk of drinking low mineral water].
Shu, Weiqun
2015-10-01
The consumption of low mineral drinking water has been increasing around the world with the shortage of water resources and the development of advanced water treatment technologies. Evidences from systematic document reviews, ecological epidemiological observations, and experimental drinking water intervention studies indicate that lack of minerals in drinking water may cause direct or indirect harm to human health, among which, the associations of magnesium in water with cardiovascular disease, as well as calcium in water with osteoporosis, are well proved by sufficient evidence. This article points out that it is urgent to pay more attention to the issues about establishment of health risk evaluation system on susceptible consuming population, establishment of lab evaluation system on water quality and health effect for non-traditional drinking water, and program of safety mineralization for demineralized or desalinated water and so on.
Murphy, H M; Thomas, M K; Medeiros, D T; McFADYEN, S; Pintar, K D M
2016-05-01
The estimated burden of endemic acute gastrointestinal illness (AGI) annually in Canada is 20·5 million cases. Approximately 4 million of these cases are domestically acquired and foodborne, yet the proportion of waterborne cases is unknown. A number of randomized controlled trials have been completed to estimate the influence of tap water from municipal drinking water plants on the burden of AGI. In Canada, 83% of the population (28 521 761 people) consumes tap water from municipal drinking water plants serving >1000 people. The drinking water-related AGI burden associated with the consumption of water from these systems in Canada is unknown. The objective of this research was to estimate the number of AGI cases attributable to consumption of drinking water from large municipal water supplies in Canada, using data from four household drinking water intervention trials. Canadian municipal water treatment systems were ranked into four categories based on source water type and quality, population size served, and treatment capability and barriers. The water treatment plants studied in the four household drinking water intervention trials were also ranked according to the aforementioned criteria, and the Canadian treatment plants were then scored against these criteria to develop four AGI risk groups. The proportion of illnesses attributed to distribution system events vs. source water quality/treatment failures was also estimated, to inform the focus of future intervention efforts. It is estimated that 334 966 cases (90% probability interval 183 006-501 026) of AGI per year are associated with the consumption of tap water from municipal systems that serve >1000 people in Canada. This study provides a framework for estimating the burden of waterborne illness at a national level and identifying existing knowledge gaps for future research and surveillance efforts, in Canada and abroad.
Liang, Jennifer L; Dziuban, Eric J; Craun, Gunther F; Hill, Vincent; Moore, Matthew R; Gelting, Richard J; Calderon, Rebecca L; Beach, Michael J; Roy, Sharon L
2006-12-22
Since 1971, CDC, the U.S. Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have maintained a collaborative Waterborne Disease and Outbreaks Surveillance System for collecting and reporting data related to occurrences and causes of waterborne disease and outbreaks (WBDOs). This surveillance system is the primary source of data concerning the scope and effects of WBDOs in the United States. Data presented summarize 36 WBDOs that occurred during January 2003-December 2004 and nine previously unreported WBDOs that occurred during 1982-2002. The surveillance system includes data on WBDOs associated with drinking water, water not intended for drinking (excluding recreational water), and water of unknown intent. Public health departments in the states, territories, localities, and Freely Associated States (i.e., the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau, formerly parts of the U.S.-administered Trust Territory of the Pacific Islands) are primarily responsible for detecting and investigating WBDOs and voluntarily reporting them to CDC by using a standard form. During 2003-2004, a total of 36 WBDOs were reported by 19 states; 30 were associated with drinking water, three were associated with water not intended for drinking, and three were associated with water of unknown intent. The 30 drinking water-associated WBDOs caused illness among an estimated 2,760 persons and were linked to four deaths. Etiologic agents were identified in 25 (83.3%) of these WBDOs: 17 (68.0%) involved pathogens (i.e., 13 bacterial, one parasitic, one viral, one mixed bacterial/parasitic, and one mixed bacterial/parasitic/viral), and eight (32.0%) involved chemical/toxin poisonings. Gastroenteritis represented 67.7% of the illness related to drinking water-associated WBDOs; acute respiratory illness represented 25.8%, and dermatitis represented 6.5%. The classification of deficiencies contributing to WBDOs has been revised to reflect the categories of concerns associated with contamination at or in the source water, treatment facility, or distribution system (SWTD) that are under the jurisdiction of water utilities, versus those at points not under the jurisdiction of a water utility or at the point of water use (NWU/POU), which includes commercially bottled water. A total of 33 deficiencies were cited in the 30 WBDOs associated with drinking water: 17 (51.5%) NWU/POU, 14 (42.4%) SWTD, and two (6.1%) unknown. The most frequently cited NWU/POU deficiencies involved Legionella spp. in the drinking water system (n = eight [47.1%]). The most frequently cited SWTD deficiencies were associated with distribution system contamination (n = six [42.9%]). Contaminated ground water was a contributing factor in seven times as many WBDOs (n = seven) as contaminated surface water (n = one). Approximately half (51.5%) of the drinking water deficiencies occurred outside the jurisdiction of a water utility in situations not currently regulated by EPA. The majority of the WBDOs in which deficiencies were not regulated by EPA were associated with Legionella spp. or chemicals/toxins. Problems in the distribution system were the most commonly identified deficiencies under the jurisdiction of a water utility, underscoring the importance of preventing contamination after water treatment. The substantial proportion of WBDOs involving contaminated ground water provides support for the Ground Water Rule (finalized in October 2006), which specifies when corrective action is required for public ground water systems. CDC and EPA use surveillance data to identify the types of water systems, deficiencies, and etiologic agents associated with WBDOs and to evaluate the adequacy of current technologies and practices for providing safe drinking water. Surveillance data also are used to establish research priorities, which can lead to improved water-quality regulation development. The growing proportion of drinking water deficiencies that are not addressed by current EPA rules emphasizes the need to address risk factors for water contamination in the distribution system and at points not under the jurisdiction of water utilities.
INEXPENSIVE DRINKING WATER CHLORINATION UNIT FOR SMALL COMMUNITIES - PHASE I
More than 250 drinking water systems exist for small communities in Puerto Rico that serve between 25 and 500 individuals. These water systems fall outside of the Puerto Rico Aqueduct and Sewer Authority and, thus, have insufficient water treatment systems or no water treatmen...
INEXPENSIVE DRINKING WATER CHLORINATION UNIT FOR SMALL COMMUNITIES - PHASE II
Over 250 drinking water systems exist for small communities in Puerto Rico that serve 25-500 individuals. These water systems fall outside of Puerto Rico Aquaduct and Sewer Authority and, thus, have no or insufficient water treatment systems. Water sources for these communit...
Manassaram, Deana M.; Backer, Lorraine C.; Moll, Deborah M.
2006-01-01
In this review we present an update on maternal exposure to nitrates in drinking water in relation to possible adverse reproductive and developmental effects, and also discuss nitrates in drinking water in the United States. The current standard for nitrates in drinking water is based on retrospective studies and approximates a level that protects infants from methemoglobinemia, but no safety factor is built into the standard. The current standard applies only to public water systems. Drinking water source was related to nitrate exposure (i.e., private systems water was more likely than community system water to have nitrate levels above the maximum contaminant limit). Animal studies have found adverse reproductive effects resulting from higher doses of nitrate or nitrite. The epidemiologic evidence of a direct exposure–response relationship between drinking water nitrate level and adverse reproductive effect is still not clear. However, some reports have suggested an association between exposure to nitrates in drinking water and spontaneous abortions, intrauterine growth restriction, and various birth defects. Uncertainties in epidemiologic studies include the lack of individual exposure assessment that would rule out confounding of the exposure with some other cause. Nitrates may be just one of the contaminants in drinking water contributing to adverse outcomes. We conclude that the current literature does not provide sufficient evidence of a causal relationship between exposure to nitrates in drinking water and adverse reproductive effects. Future studies incorporating individual exposure assessment about users of private wells—the population most at risk—should be considered. PMID:16507452
Diverse manganese(II)-oxidizing bacteria are prevalent in drinking water systems.
Marcus, Daniel N; Pinto, Ameet; Anantharaman, Karthik; Ruberg, Steven A; Kramer, Eva L; Raskin, Lutgarde; Dick, Gregory J
2017-04-01
Manganese (Mn) oxides are highly reactive minerals that influence the speciation, mobility, bioavailability and toxicity of a wide variety of organic and inorganic compounds. Although Mn(II)-oxidizing bacteria are known to catalyze the formation of Mn oxides, little is known about the organisms responsible for Mn oxidation in situ, especially in engineered environments. Mn(II)-oxidizing bacteria are important in drinking water systems, including in biofiltration and water distribution systems. Here, we used cultivation dependent and independent approaches to investigate Mn(II)-oxidizing bacteria in drinking water sources, a treatment plant and associated distribution system. We isolated 29 strains of Mn(II)-oxidizing bacteria and found that highly similar 16S rRNA gene sequences were present in all culture-independent datasets and dominant in the studied drinking water treatment plant. These results highlight a potentially important role for Mn(II)-oxidizing bacteria in drinking water systems, where biogenic Mn oxides may affect water quality in terms of aesthetic appearance, speciation of metals and oxidation of organic and inorganic compounds. Deciphering the ecology of these organisms and the factors that regulate their Mn(II)-oxidizing activity could yield important insights into how microbial communities influence the quality of drinking water. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.
There is evidence that drinking water may be a source of pathogenic nontuberculous mycobacteria (NTM) infections in humans. One method by which NTM are believed to enter drinking water distribution systems is by their intracellular colonization of protozoa. Our goal was to determ...
There is evidence that drinking water may be a source of pathogenic nontuberculous mycobacteria (NTM) infections in humans. One method by which NTM are believed to enter drinking water distribution systems is by their intracellular location within protozoa. Our goal was to determ...
The Watts Premier WP-4V POU drinking water treatment system was tested for removal of aldicarb, benzene, cadmium, carbofuran, cesium, chloroform, dichlorvos, dicrotophos, fenamiphos, mercury, mevinphos, oxamyl, strontium, and strychnine. The WP-4V employs a reverse osmosis (RO) m...
The persistence of Mycobacterium avium in a drinking water system, what is the risk to human health?
Drinking water is believed to be a major source of human exposure to nontuberculous mycobacteria (NTM) such as Mycobacterium avium. We monitored the prevalence of M. avium in a drinking water system during the addition of filtration treatment. Our goal was to determine if the pre...
[Surveillance of drinking water supply systems on markets and in vehicles].
Rädel, U; Puchert, W; Suchenwirth, R
2007-03-01
The new German Drinking Water Ordinance (TrinkwV 2001) demands that the requirements of water intended for human consumption be met up to the intrinsic tap, at which the water is used. This also applies to water supply systems for food trade aboard non-stationary facilities and in vehicles for commercial purposes. In contrast to stationary units for drinking water supply, the nonstationary units relocate and the responsibility changes with each public health authority agent. Therefore, a coordinated action between the federal states is desirable and necessary. The experience of the public health departments presents many non-compliant parameters of microbiology in water supply systems on markets and in vehicles. The development of practical and consistent recommendations for the surveillance of non-stationary units is required to give consistent standards to the users. The article gives a review about legal foundations and technical rules in order to define the drinking water supply systems on markets and in vehicles in compliance with the German Drinking Water Ordinance. Examples of laboratory results from different monitoring episodes from three federal states are shown.
Nitrification in drinking water distribution systems is a concern of many drinking water systems. Although chloramination as a source of nitrification (i.e., addition of excess ammonia or breakdown of chloramines) has drawn the most attention, many source waters contain signific...
75 FR 75761 - Water Quality Standards for the State of Florida's Lakes and Flowing Waters
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-06
... widespread, persistent, and growing problem. Nitrogen/phosphorus pollution in fresh water systems can... Florida's regulated drinking water systems and a 10 mg/L criteria for nitrate in Class I waters. FDEP..., kidney, and central nervous system problems. 44 45 \\44\\ USEPA. 2009. National Primary Drinking Water...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Aircraft water system operations and maintenance plan. 141.804 Section 141.804 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.804 Aircraft water system...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... Public Hearing for Public Water System Supervision Program Revision for New York AGENCY: Environmental... approved Public Water System Supervision Program to adopt EPA's National Primary Drinking Water Regulations..., 24th Floor Drinking Water Ground Water Protection Section, 290 Broadway, New York, New York 10007-1866...
Testing large volume water treatment and crude oil ...
Report EPA’s Homeland Security Research Program (HSRP) partnered with the Idaho National Laboratory (INL) to build the Water Security Test Bed (WSTB) at the INL test site outside of Idaho Falls, Idaho. The WSTB was built using an 8-inch (20 cm) diameter cement-mortar lined drinking water pipe that was previously taken out of service. The pipe was exhumed from the INL grounds and oriented in the shape of a small drinking water distribution system. Effluent from the pipe is captured in a lagoon. The WSTB can support drinking water distribution system research on a variety of drinking water treatment topics including biofilms, water quality, sensors, and homeland security related contaminants. Because the WSTB is constructed of real drinking water distribution system pipes, research can be conducted under conditions similar to those in a real drinking water system. In 2014, WSTB pipe was experimentally contaminated with Bacillus globigii spores, a non-pathogenic surrogate for the pathogenic B. anthracis, and then decontaminated using chlorine dioxide. In 2015, the WSTB was used to perform the following experiments: • Four mobile disinfection technologies were tested for their ability to disinfect large volumes of biologically contaminated “dirty” water from the WSTB. B. globigii spores acted as the biological contaminant. The four technologies evaluated included: (1) Hayward Saline C™ 6.0 Chlorination System, (2) Advanced Oxidation Process (A
Biological instability in a chlorinated drinking water distribution network.
Nescerecka, Alina; Rubulis, Janis; Vital, Marius; Juhna, Talis; Hammes, Frederik
2014-01-01
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×10(3) cells mL(-1) to 4.66×10(5) cells mL(-1) in the network. While this parameter did not exceed 2.1×10(4) cells mL(-1) in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×10(5) cells mL(-1). This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.
Biological Instability in a Chlorinated Drinking Water Distribution Network
Nescerecka, Alina; Rubulis, Janis; Vital, Marius; Juhna, Talis; Hammes, Frederik
2014-01-01
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×103 cells mL−1 to 4.66×105 cells mL−1 in the network. While this parameter did not exceed 2.1×104 cells mL−1 in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×105 cells mL−1. This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability. PMID:24796923
ATRAZOME CHLORINATION TRANSFORMATION PRODUCTS UNDER DRINKING WATER DISTRIBUTION SYSTEM CONDITIONS
Chlorination is a commonly-used disinfectant step in drinking water treatment. Should free chlorine be added to water used as a drinking water source, it is widely understood that many biological species in the water, along with dissolved organic and inorganic chemicals, will rea...
Flores Ribeiro, Angela; Bodilis, Josselin; Alonso, Lise; Buquet, Sylvaine; Feuilloley, Marc; Dupont, Jean-Paul; Pawlak, Barbara
2014-08-15
Aquatic environments could play a role in the spread of antibiotic resistance genes by enabling antibiotic-resistant bacteria transferred through wastewater inputs to connect with autochthonous bacteria. Consequently, drinking water could be a potential pathway to humans and animals for antibiotic resistance genes. The aim of this study was to investigate occurrences of Escherichia coli and Pseudomonas spp. in drinking water produced from a karst, a vulnerable aquifer with frequent increases in water turbidity after rainfall events and run-offs. Water samples were collected throughout the system from the karstic springs to the drinking water tap during three non-turbid periods and two turbid events. E. coli densities in the springs were 10- to 1000-fold higher during the turbid events than during the non-turbid periods, indicating that, with increased turbidity, surface water had entered the karstic system and contaminated the spring water. However, no E. coli were isolated in the drinking water. In contrast, Pseudomonas spp. were isolated from the drinking water only during turbid events, while the densities in the springs were from 10- to 100-fold higher than in the non-turbid periods. All the 580 Pseudomonas spp. isolates obtained from the sampling periods were resistant (to between 1 and 10 antibiotics), with similar resistance patterns. Among all the Pseudomonas isolated throughout the drinking water production system, between 32% and 86% carried the major resistance pattern: ticarcillin, ticarcillin-clavulanic acid, cefsulodin, and/or aztreonam, and/or sulfamethoxazol-trimethoprim, and/or fosfomycin. Finally, 8 Pseudomonas spp. isolates, related to the Pseudomonas putida and Pseudomonas fluorescens species, were isolated from the drinking water. Thus, Pseudomonas could be involved in the dissemination of antibiotic resistance via drinking water during critical periods. Copyright © 2014 Elsevier B.V. All rights reserved.
Artificial sweetener sucralose in U.S. drinking water systems.
Mawhinney, Douglas B; Young, Robert B; Vanderford, Brett J; Borch, Thomas; Snyder, Shane A
2011-10-15
The artificial sweetener sucralose has recently been shown to be a widespread of contaminant of wastewater, surface water, and groundwater. In order to understand its occurrence in drinking water systems, water samples from 19 United States (U.S.) drinking water treatment plants (DWTPs) serving more than 28 million people were analyzed for sucralose using liquid chromatography tandem mass spectrometry (LC-MS/MS). Sucralose was found to be present in source water of 15 out of 19 DWTPs (47-2900 ng/L), finished water of 13 out of 17 DWTPs (49-2400 ng/L) and distribution system water of 8 out of the 12 DWTPs (48-2400 ng/L) tested. Sucralose was only found to be present in source waters with known wastewater influence and/or recreational usage, and displayed low removal (12% average) in the DWTPs where finished water was sampled. Further, in the subset of DWTPs with distribution system water sampled, the compound was found to persist regardless of the presence of residual chlorine or chloramines. In order to understand intra-DWTP consistency, sucralose was monitored at one drinking water treatment plant over an 11 month period from March 2010 through January 2011, and averaged 440 ng/L in the source water and 350 ng/L in the finished water. The results of this study confirm that sucralose will function well as an indicator compound for anthropogenic influence on source, finished drinking and distribution system (i.e., tap) water, as well as an indicator compound for the presence of other recalcitrant compounds in finished drinking water in the U.S.
[Analysis on current status of drinking water quality in rural areas of China].
Zhang, L; Chen, Y; Chen, C; Wang, H; Yan, H Z; Zhao, Y C
1997-01-01
An investigation on drinking water quality in rural areas of 180 counties in 26 provinces, municipalities and autonomous regions of China was carried out. The population surveyed was 89.39 million. 69.6% of which was supplied with ground water. Central water supply systems served 47.1% of population. Quality of drinking water was graded according to the "Guidelines for Implementation of the 'Sanitary Standard for Drinking Water' in Rural Areas". The rate of population supplied with unqualified drinking water was 42.7%. The bacteriological indices of drinking water exceeded the standard seriously. Organic pollution occurred extensively. Some regions supplied with water of high concentration of fluoride.
Galway, Lindsay P.
2016-01-01
Access to safe and reliable drinking water is commonplace for most Canadians. However, the right to safe and reliable drinking water is denied to many First Nations peoples across the country, highlighting a priority public health and environmental justice issue in Canada. This paper describes trends and characteristics of drinking water advisories, used as a proxy for reliable access to safe drinking water, among First Nations communities in the province of Ontario. Visual and statistical tools were used to summarize the advisory data in general, temporal trends, and characteristics of the drinking water systems in which advisories were issued. Overall, 402 advisories were issued during the study period. The number of advisories increased from 25 in 2004 to 75 in 2013. The average advisory duration was 294 days. Most advisories were reported in summer months and equipment malfunction was the most commonly reported reason for issuing an advisory. Nearly half of all advisories occurred in drinking water systems where additional operator training was needed. These findings underscore that the prevalence of drinking water advisories in First Nations communities is a problem that must be addressed. Concerted and multi-faceted efforts are called for to improve the provision of safe and reliable drinking water First Nations communities. PMID:27196919
Galway, Lindsay P
2016-05-17
Access to safe and reliable drinking water is commonplace for most Canadians. However, the right to safe and reliable drinking water is denied to many First Nations peoples across the country, highlighting a priority public health and environmental justice issue in Canada. This paper describes trends and characteristics of drinking water advisories, used as a proxy for reliable access to safe drinking water, among First Nations communities in the province of Ontario. Visual and statistical tools were used to summarize the advisory data in general, temporal trends, and characteristics of the drinking water systems in which advisories were issued. Overall, 402 advisories were issued during the study period. The number of advisories increased from 25 in 2004 to 75 in 2013. The average advisory duration was 294 days. Most advisories were reported in summer months and equipment malfunction was the most commonly reported reason for issuing an advisory. Nearly half of all advisories occurred in drinking water systems where additional operator training was needed. These findings underscore that the prevalence of drinking water advisories in First Nations communities is a problem that must be addressed. Concerted and multi-faceted efforts are called for to improve the provision of safe and reliable drinking water First Nations communities.
Occurrence of pharmaceuticals in a water supply system and related human health risk assessment.
de Jesus Gaffney, Vanessa; Almeida, Cristina M M; Rodrigues, Alexandre; Ferreira, Elisabete; Benoliel, Maria João; Cardoso, Vitor Vale
2015-04-01
A monitoring study of 31 pharmaceuticals along Lisbon's drinking water supply system was implemented, which comprised the analysis of 250 samples including raw water (surface water and groundwater), and drinking water. Of the 31 pharmaceutical compounds, only sixteen were quantified in the analyzed samples, with levels ranging from 0.005 to 46 ng/L in raw water samples and 0.09-46 ng/L in drinking water samples. The human health risk assessment performed showed that appreciable risks to the consumer's health arising from exposure to trace levels of pharmaceuticals in drinking water are extremely unlikely, as RQs values were all below 0.001. Also, pharmaceuticals were selected as indicators to be used as a tool to control the quality of raw water and the treatment efficiency in the drinking water treatment plants. Copyright © 2014 Elsevier Ltd. All rights reserved.
MODELING CONTAMINANT PROPAGATION IN DRINKING WATER DISTRIBUTION SYSTEMS
The Safe Drinking Water Act and its Amendments (SDWAA) will pose a massive challenge for the drinking-water industry in the United States. As the SDWAA regulations reach implementation, increasing effort will be devoted to understanding the factors causing deterioration of water ...
Disinfection By-Products: Formation and Occurrence in Drinking Water
The disinfection of drinking water has been rightly hailed as a public health triumph of the twentieth century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended he...
Blokker, E J Mirjam; van de Ven, Bianca M; de Jongh, Cindy M; Slaats, P G G Nellie
2013-05-01
Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. We estimated the potential human cancer risk from PAHs in coated cast iron water mains. In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations.
van de Ven, Bianca M.; de Jongh, Cindy M.
2013-01-01
Background: Coal tar and bitumen have been historically used to coat the insides of cast iron drinking water mains. Polycyclic aromatic hydrocarbons (PAHs) may leach from these coatings into the drinking water and form a potential health risk for humans. Objective: We estimated the potential human cancer risk from PAHs in coated cast iron water mains. Method: In a Dutch nationwide study, we collected drinking water samples at 120 locations over a period of 17 days under various operational conditions, such as undisturbed operation, during flushing of pipes, and after a mains repair, and analyzed these samples for PAHs. We then estimated the health risk associated with an exposure scenario over a lifetime. Results: During flushing, PAH levels frequently exceeded drinking water quality standards; after flushing, these levels dropped rapidly. After the repair of cast iron water mains, PAH levels exceeded the drinking water standards for up to 40 days in some locations. Conclusions: The estimated margin of exposure for PAH exposure through drinking water was > 10,000 for all 120 measurement locations, which suggests that PAH exposure through drinking water is of low concern for consumer health. However, factors that differ among water systems, such as the use of chlorination for disinfection, may influence PAH levels in other locations. PMID:23425894
40 CFR 141.201 - General public notification requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.201 General public notification requirements. Public water systems in States with primacy for the public water system supervision (PWSS) program must comply with the requirements in this...
40 CFR 141.201 - General public notification requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.201 General public notification requirements. Public water systems in States with primacy for the public water system supervision (PWSS) program must comply with the requirements in this...
40 CFR 141.201 - General public notification requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.201 General public notification requirements. Public water systems in States with primacy for the public water system supervision (PWSS) program must comply with the requirements in this...
40 CFR 141.201 - General public notification requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.201 General public notification requirements. Public water systems in States with primacy for the public water system supervision (PWSS) program must comply with the requirements in this...
The Purefecta™ was tested for removal of bacteria and viruses at NSF International's Drinking Water Treatment Systems Laboratory. Kinetico submitted 10 units for testing, which were split into two groups of five. One group received 25 days of conditioning prior to challeng...
We report the draft genome sequences of four Mycobacterium chelonae group strains from biofilms obtained after a ‘chlorine burn’ in a chloraminated drinking water distribution system simulator. These opportunistic pathogens have been detected in drinking and hospital water distr...
Reducing and verifying haloacetic acids in treated drinking water using a biological filter system.
Lou, Jie C; Chan, Hung Y; Yang, Chih Y; Tseng, Wei B; Han, Jia Y
2014-01-01
This study focused on reducing the haloacetic acid (HAA) concentrations in treated drinking water. HAA has been thought to be one possible nutrient supporting heterotrophic bacteria regrowth in drinking water. In this study, experiments were conducted using a pilot-scale system to evaluate the efficiency of biological filters (BF) for reducing excess HAA concentrations in water. The BF system reduced the total HAA concentration and the concentrations of five HAA species in the water. Dichloroacetic acid (DCAA), monobromoacetic acid (MBAA) and dibromoacetic acid (DBAA) were the three main HAA5 species that were present in the treated drinking water in this investigation. Combined, these three species represent approximately 77% of the HAA5 in the finished water after BF. The verification of the empirical HAA equation for the outlet in the BF system indicated linear relationships with high correlation coefficients. The empirical equation for the HAA5 concentrations in the finished water was established by examining other nutrients (e.g., dissolved organic carbon (DOC), ultraviolet absorbance at 254 nm wavelength (UV254), and ammonia nitrogen) that can reduce pathogenic contamination. These findings may be useful for designing advanced processes for conventional water treatment plants or for managing water treatment and distribution systems for providing high-quality drinking water.
The EcoWater Systems ERO-R450E POU drinking water treatment system was tested for removal of aldicarb, benzene, cadmium, carbofuran, cesium, chloroform, dichlorvos, dicrotophos, fenamiphos, mercury, mevinphos, oxamyl, strontium, and strychnine. The ERO-R450E employs a reverse os...
The primary object of the microbiology of drinking water is to prevent waterborne disease. A drinking-water system can minimize waterborne disease by employing proper treatment and cntrol practices, and by monitoring the effectiveness of these practices. Here, these issues are ad...
Safe Drinking Water Information System Federal Version (SDWIS/FED)
SDWIS/FED is EPA’s national database that manages and collects public water system information from states, including reports of drinking water standard violations, reporting and monitoring violations, and other basic information.
Mayer, Michael; Keller, Adrian; Szewzyk, Ulrich; Warnecke, Hans-Joachim
2015-05-10
Pure drinking water is the basis for a healthy society. In Germany the drinking water regulations demand for analysis of water via detection of certain microbiological parameters by cultivation only. However, not all prokaryotes can be detected by these standard methods. How to gain more and better information about the bacteria present in drinking water and its distribution systems? The biofilms in drinking water distribution systems are built by bacteria and therefore represent a valuable source of information about the species present. Unfortunately, these biofilms are badly accessible. We thus exploited the circumstance that a lot of metazoans graze the biofilms, so that the content of their guts partly reflects the respective biofilm biocenosis. Therefore, we collected omnivorous isopods, prepared their guts and examined and characterized their contents based on 16S und 18S rDNA analysis. These molecularbiological investigations provide a profound basis for the characterization of the biocenosis and thereby biologically assess the drinking water ecosystems. Combined with a thorough identification of the species and the knowledge of their habitats, this approach can provide useful indications for the assessment of drinking-water quality and the early detection of problems in the distribution system. Copyright © 2015 Elsevier B.V. All rights reserved.
Jovanovic, Dragana; Jakovljević, Branko; Rašić-Milutinović, Zorica; Paunović, Katarina; Peković, Gordana; Knezević, Tanja
2011-02-01
Vojvodina, a northern region of Serbia, belongs to the Pannonian Basin, whose aquifers contain high concentrations of arsenic. This study represents arsenic levels in drinking water in ten municipalities in Serbia. Around 63% of all water samples exceeded Serbian and European standards for arsenic in drinking water. Large variations in arsenic were observed among supply systems. Arsenic concentrations in public water supply systems in Vojvodina were much higher than in other countries in the Pannonian Basin. Copyright © 2010 Elsevier Inc. All rights reserved.
The Next Generation of Drinking Water Disinfection By-Products
The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended healt...
The Effect of Oxidant and Redox Potential on Metal Corrosion in Drinking Water
Future drinking water regulatory action may require some water utilities to consider additional and/or alternative oxidation and disinfection practices. There is little known about the effect of oxidant changes on the corrosion of drinking water distribution system materials and ...
THE PRESENCE OF ARSENIC IN DRINKING WATER DISTRIBUTION SOLIDS
The objective of this presentation was to determine whether solids found in drinking water distribution systems contain arsenic. Distribution system pipes and solids removed during hydrant flushing were collected from the distribution system of eight water utilities that had mea...
2011-01-01
Potable drinking water is essential to public health; however, few studies have investigated income or racial disparities in water infrastructure or drinking water quality. There were many case reports documenting a lack of piped water or serious water quality problems in low income and minority communities, including tribal lands, Alaskan Native villages, colonias along the United States–Mexico border, and small communities in agricultural areas. Only 3 studies compared the demographic characteristics of communities by the quality of their drinking water, and the results were mixed in these studies. Further assessments were hampered by difficulties linking specific water systems to the sociodemographic characteristics of communities, as well as little information about how well water systems operated and the effectiveness of governmental oversight. PMID:21836110
VanDerslice, James
2011-12-01
Potable drinking water is essential to public health; however, few studies have investigated income or racial disparities in water infrastructure or drinking water quality. There were many case reports documenting a lack of piped water or serious water quality problems in low income and minority communities, including tribal lands, Alaskan Native villages, colonias along the United States-Mexico border, and small communities in agricultural areas. Only 3 studies compared the demographic characteristics of communities by the quality of their drinking water, and the results were mixed in these studies. Further assessments were hampered by difficulties linking specific water systems to the sociodemographic characteristics of communities, as well as little information about how well water systems operated and the effectiveness of governmental oversight.
The importance of waterborne disease outbreak surveillance in the United States.
Craun, Gunther Franz
2012-01-01
Analyses of the causes of disease outbreaks associated with contaminated drinking water in the United States have helped inform prevention efforts at the national, state, and local levels. This article describes the changing nature of disease outbreaks in public water systems during 1971-2008 and discusses the importance of a collaborative waterborne outbreak surveillance system established in 1971. Increasing reports of outbreaks throughout the early 1980s emphasized that microbial contaminants remained a health-risk challenge for suppliers of drinking water. Outbreak investigations identified the responsible etiologic agents and deficiencies in the treatment and distribution of drinking water, especially the high risk associated with unfiltered surface water systems. Surveillance information was important in establishing an effective research program that guided government regulations and industry actions to improve drinking water quality. Recent surveillance statistics suggest that prevention efforts based on these research findings have been effective in reducing outbreak risks especially for surface water systems.
Drinking water treatment plants rely on purification of contaminated source waters to provide communities with potable water. One group of possible contaminants are enteric viruses. Measurement of viral quantities in environmental water systems are often performed using polymeras...
The nature of iron tubercles inside unlined iron pipes of drinking water distribution systems are influenced by water quality and therefore susceptible to changes in water chemistry. The underlying assumption is that tubercles in a system have similar physio-chemical properties. ...
Application of a risk management system to improve drinking water safety.
Jayaratne, Asoka
2008-12-01
The use of a comprehensive risk management framework is considered a very effective means of managing water quality risks. There are many risk-based systems available to water utilities such as ISO 9001 and Hazard Analysis and Critical Control Point (HACCP). In 2004, the World Health Organization's (WHO) Guidelines for Drinking Water Quality recommended the use of preventive risk management approaches to manage water quality risks. This paper describes the framework adopted by Yarra Valley Water for the development of its Drinking Water Quality Risk Management Plan incorporating HACCP and ISO 9001 systems and demonstrates benefits of Water Safety Plans such as HACCP. Copyright IWA Publishing 2008.
Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges.
Prest, Emmanuelle I; Hammes, Frederik; van Loosdrecht, Mark C M; Vrouwenvelder, Johannes S
2016-01-01
Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to maintain good drinking water microbial quality up to consumer's tap. A new definition and methodological approach for biological stability is proposed.
Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges
Prest, Emmanuelle I.; Hammes, Frederik; van Loosdrecht, Mark C. M.; Vrouwenvelder, Johannes S.
2016-01-01
Biological stability of drinking water refers to the concept of providing consumers with drinking water of same microbial quality at the tap as produced at the water treatment facility. However, uncontrolled growth of bacteria can occur during distribution in water mains and premise plumbing, and can lead to hygienic (e.g., development of opportunistic pathogens), aesthetic (e.g., deterioration of taste, odor, color) or operational (e.g., fouling or biocorrosion of pipes) problems. Drinking water contains diverse microorganisms competing for limited available nutrients for growth. Bacterial growth and interactions are regulated by factors, such as (i) type and concentration of available organic and inorganic nutrients, (ii) type and concentration of residual disinfectant, (iii) presence of predators, such as protozoa and invertebrates, (iv) environmental conditions, such as water temperature, and (v) spatial location of microorganisms (bulk water, sediment, or biofilm). Water treatment and distribution conditions in water mains and premise plumbing affect each of these factors and shape bacterial community characteristics (abundance, composition, viability) in distribution systems. Improved understanding of bacterial interactions in distribution systems and of environmental conditions impact is needed for better control of bacterial communities during drinking water production and distribution. This article reviews (i) existing knowledge on biological stability controlling factors and (ii) how these factors are affected by drinking water production and distribution conditions. In addition, (iii) the concept of biological stability is discussed in light of experience with well-established and new analytical methods, enabling high throughput analysis and in-depth characterization of bacterial communities in drinking water. We discussed, how knowledge gained from novel techniques will improve design and monitoring of water treatment and distribution systems in order to maintain good drinking water microbial quality up to consumer’s tap. A new definition and methodological approach for biological stability is proposed. PMID:26870010
Khan, Stuart J; Deere, Daniel; Leusch, Frederic D L; Humpage, Andrew; Jenkins, Madeleine; Cunliffe, David
2015-11-15
Among the most widely predicted and accepted consequences of global climate change are increases in both the frequency and severity of a variety of extreme weather events. Such weather events include heavy rainfall and floods, cyclones, droughts, heatwaves, extreme cold, and wildfires, each of which can potentially impact drinking water quality by affecting water catchments, storage reservoirs, the performance of water treatment processes or the integrity of distribution systems. Drinking water guidelines, such as the Australian Drinking Water Guidelines and the World Health Organization Guidelines for Drinking-water Quality, provide guidance for the safe management of drinking water. These documents present principles and strategies for managing risks that may be posed to drinking water quality. While these principles and strategies are applicable to all types of water quality risks, very little specific attention has been paid to the management of extreme weather events. We present a review of recent literature on water quality impacts of extreme weather events and consider practical opportunities for improved guidance for water managers. We conclude that there is a case for an enhanced focus on the management of water quality impacts from extreme weather events in future revisions of water quality guidance documents. Copyright © 2015 Elsevier Ltd. All rights reserved.
Working with Communities to Solve a Big Problem in Small Water Systems
Ammonia is found at high levels in many agricultural areas where groundwater is the primary drinking water source. EPA researchers developed affordable and easy-to-use biological drinking water treatment systems to treat ammonia in water.
Akaizina, A E; Akaizin, E S; Starodumov, V L
2015-01-01
The use of modern methods of analysis is aimed to the search of ultimately novel biological markers. Volatile fatty acids in saliva were not used previously for the assessment of the effects of contaminating substances in the drinking water on the body of children. The aim of the study is to investigate the informative value of volatile fatty acids in saliva as biological markers of the impact for the assessment of the exposure to contaminating substances in the drinking water on the body of children. Hygienic assessment of drinking water quality was made according to data of the own research of drinking water from centralized supply system of the city of Ivanovo. For the comparison of indices there was investigated the drinking water from wells at the village Podvyaznovsky of the Ivanovo region. In the Ivanovo water from the distributing network of centralized drinking water supply system of the city of Ivanovo, there were identified indices of the permanganate oxidation and the total concentration of residual chlorine exceeding norms, and also chloroform and carbon tetrachloride were in concentrations not exceeding the norms. Studied by us the samples of drinking water from Podvyaznovsky village wells, the water met the standards for all investigated parameters. The was studied the informative value of volatile fatty acids in the saliva of children aged 9-14 years from the city of Ivanovo and the Podvyaznovsky village, Ivanovo region. There was established the fall in acetic, butyric, isovaleric acids and the total amount of volatile fatty acids in the saliva in children of the city of Ivanovo, consuming water treated with chlorine of Ivanovo centralized drinking water supply system. Indices of volatile fatty acids in saliva are informative for the assessment of the impact of organic pollutants, residual chlorine and organic chlorine compounds of drinking water on the body of children.
A Systems Approach to Manage Drinking Water Quality ...
Drinking water supplies can be vulnerable to impacts from short-term weather events, long-term changes in land-use and climate, and water quality controls in treatment and distribution. Disinfection by-product (DBP) formation in drinking water is a prominent example to illustrate the water supply vulnerability and examine technological options in adaptation. Total organic carbon (TOC) in surface water can vary significantly due to changes or a combination of changes in watershed land use, climate variability, and extreme meteorological events (e.g., hurricanes). On the other hand, water demand is known to vary temporarily and spatially leading to changes in water ages and hence DBP formation potential. Typically a drinking water facility is designed to operate within a projected range of influent water quality and water demand. When the variations exceed the design range, water supply becomes vulnerable in the compliance to Safe Drinking Water Act (SDWA) Stage-II disinfection by-product (DBP) rules. This paper describes a framework of systems-level modeling, monitoring and control in adaptive planning and system operation. The framework, built upon the integration of model projections, adaptive monitoring and systems control, has three primary functions. Its advantages and limitations will be discussed with the application examples in Cincinnati (Ohio, USA) and Las Vegas (Nevada, USA). At a conceptual level, an integrated land use and hydrological model
Small Drinking Water Systems Research and Development
In the United States, there are 152,002 public water systems (PWS) in operation. Of these, 97% are considered small systems under the Safe Drinking Water Act (SDWA)—meaning they serve 10,000 or fewer people. While many of these small systems consistently provide safe, relia...
Zlatanović, Lj; van der Hoek, J P; Vreeburg, J H G
2017-10-15
The drinking water quality changes during the transport through distribution systems. Domestic drinking water systems (DDWSs), which include the plumbing between the water meter and consumer's taps, are the most critical points in which water quality may be affected. In distribution networks, the drinking water temperature and water residence time are regarded as indicators of the drinking water quality. This paper describes an experimental research on the influence of stagnation time and temperature change on drinking water quality in a full-scale DDWS. Two sets of stagnation experiments, during winter and summer months, with various stagnation intervals (up to 168 h of stagnation) were carried out. Water and biofilms were sampled at two different taps, a kitchen and a shower tap. Results from this study indicate that temperature and water stagnation affect both chemical and microbial quality in DDWSs, whereas microbial parameters in stagnant water appear to be driven by the temperature of fresh water. Biofilm formed in the shower pipe contained more total and intact cells than the kitchen pipe biofilm. Alphaproteobacteria were found to dominate in the shower biofilm (78% of all Proteobacteria), while in the kitchen tap biofilm Alphaproteobacteria, Betaproteobacteria and Gammaproteobacteria were evenly distributed. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Drinking Water Quality Status and Contamination in Pakistan
Nafees, Muhammad; Rizwan, Muhammad; Bajwa, Raees Ahmad; Shakoor, Muhammad Bilal; Arshad, Muhammad Umair; Chatha, Shahzad Ali Shahid; Deeba, Farah; Murad, Waheed; Malook, Ijaz
2017-01-01
Due to alarming increase in population and rapid industrialization, drinking water quality is being deteriorated day by day in Pakistan. This review sums up the outcomes of various research studies conducted for drinking water quality status of different areas of Pakistan by taking into account the physicochemical properties of drinking water as well as the presence of various pathogenic microorganisms. About 20% of the whole population of Pakistan has access to safe drinking water. The remaining 80% of population is forced to use unsafe drinking water due to the scarcity of safe and healthy drinking water sources. The primary source of contamination is sewerage (fecal) which is extensively discharged into drinking water system supplies. Secondary source of pollution is the disposal of toxic chemicals from industrial effluents, pesticides, and fertilizers from agriculture sources into the water bodies. Anthropogenic activities cause waterborne diseases that constitute about 80% of all diseases and are responsible for 33% of deaths. This review highlights the drinking water quality, contamination sources, sanitation situation, and effects of unsafe drinking water on humans. There is immediate need to take protective measures and treatment technologies to overcome unhygienic condition of drinking water supplies in different areas of Pakistan. PMID:28884130
Drinking Water Quality Status and Contamination in Pakistan.
Daud, M K; Nafees, Muhammad; Ali, Shafaqat; Rizwan, Muhammad; Bajwa, Raees Ahmad; Shakoor, Muhammad Bilal; Arshad, Muhammad Umair; Chatha, Shahzad Ali Shahid; Deeba, Farah; Murad, Waheed; Malook, Ijaz; Zhu, Shui Jin
2017-01-01
Due to alarming increase in population and rapid industrialization, drinking water quality is being deteriorated day by day in Pakistan. This review sums up the outcomes of various research studies conducted for drinking water quality status of different areas of Pakistan by taking into account the physicochemical properties of drinking water as well as the presence of various pathogenic microorganisms. About 20% of the whole population of Pakistan has access to safe drinking water. The remaining 80% of population is forced to use unsafe drinking water due to the scarcity of safe and healthy drinking water sources. The primary source of contamination is sewerage (fecal) which is extensively discharged into drinking water system supplies. Secondary source of pollution is the disposal of toxic chemicals from industrial effluents, pesticides, and fertilizers from agriculture sources into the water bodies. Anthropogenic activities cause waterborne diseases that constitute about 80% of all diseases and are responsible for 33% of deaths. This review highlights the drinking water quality, contamination sources, sanitation situation, and effects of unsafe drinking water on humans. There is immediate need to take protective measures and treatment technologies to overcome unhygienic condition of drinking water supplies in different areas of Pakistan.
Impact of particles on sediment accumulation in a drinking water distribution system.
Vreeburg, J H G; Schippers, D; Verberk, J Q J C; van Dijk, J C
2008-10-01
Discolouration of drinking water is one of the main reasons customers complain to their water company. Though corrosion of cast iron is often seen as the main source for this problem, the particles originating from the treatment plant play an important and potentially dominant role in the generation of a discolouration risk in drinking water distribution systems. To investigate this thesis a study was performed in a drinking water distribution system. In two similar isolated network areas the effect of particles on discolouration risk was studied with particle counting, the Resuspension Potential Method (RPM) and assessment of the total accumulated sediment. In the 'Control Area', supplied with normal drinking water, the discolouration risk was regenerated within 1.5 year. In the 'Research Area', supplied with particle-free water, this will take 10-15 years. An obvious remedy for controlling the discolouration risk is to improve the treatment with respect to the short peaks that are caused by particle breakthrough.
DISINFECTION BY-PRODUCTS IN DRINKING WATER TREATMENT SYSTEMS
Due to concerns over trihalomethanes (THMs) and other halogenated by-products that can be formed during chlorination of drinking water, alternative disinfectants are being explored. Several drinking water treatment plants in the United States have altered their treatment methods...
Drinking Water State Revolving Fund: EPA Funding for ...
2017-07-06
The Safe Drinking Water Act (SDWA) Amendments of 1996 (Pub. L. 104-182) authorize a Drinking Water State Revolving Fund (DWSRF) program to assist public water systems to finance the costs of infrastructure needed to achieve or maintain compliance with SDWA requirements and to protect public health.
Nitrification within drinking water distribution systems reduces water quality, causes difficulties maintaining adequate disinfectant residual, and poses public health concerns including exposure to nitrite, nitrate, and opportunistic pathogenic microorganisms. Monochloramine is...
Methods for Environments and Contaminants: Drinking Water
EPA’s Safe Drinking Water Information System Federal Version (SDWIS/FED) includes information on populations served and violations of maximum contaminant levels or required treatment techniques by the nation’s 160,000 public water systems.
Optimization Program for Drinking Water Systems
The Area-Wide Optimization Program (AWOP) provides tools and approaches for drinking water systems to meet water quality optimization goals and provide an increased – and sustainable – level of public health protection to their consumers.
Grigorescu, A S; Hozalski, R M; Lapara, T M
2012-04-01
To characterize the HAA-degrading bacteria in drinking water systems. Haloacetic acid (HAA)-degrading bacteria were analysed in drinking water systems by cultivation and by a novel application of terminal restriction fragment length polymorphism (tRFLP). Substantial similarities were observed among the tRFLP patterns of dehI and dehII gene fragments in drinking water samples obtained from three different cities (Minneapolis, MN; St Paul, MN; Bucharest, Romania) and from one biologically active granular activated carbon filter (Hershey, PA). The dominant fragment in the tRFLP profiles of dehI genes from the drinking water samples matched the pattern from an Afipia sp. that was previously isolated from drinking water. In contrast, the dominant fragment in the tRFLP profiles of dehII genes did not match any previously characterized dehII gene fragment. PCR cloning was used to characterize this gene fragment, which had <65% nucleotide sequence identity with any previously characterized dehII gene. Afipia spp. are an appropriate model organism for studying the biodegradation of HAAs in drinking water distribution systems as encoded by dehI genes; the organism that harbours the most prominent dehII gene in drinking water has yet to be cultivated and identified. The development of a novel application of tRFLP targeting dehI and dehII genes could be broadly useful in understanding HAA-degrading bacteria in numerous environments. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
SAFE DRINKING WATER FROM SMALL SYSTEMS: TREATMENT OPTIONS
Bringing small water systems into compliance with the ever-increasing number of regulations will require flexibility in terms of technology application and institional procedures. his article looks at the means by which small systems can provide safe drinking water, focusing on t...
The microbial community structure was investigated from bulk phase water samples of multiple collection sites from two service areas within the Cincinnati drinking water distribution system (DWDS). Each area is associated with a different primary source of water (i.e., groundwat...
Varol, Simge; Davraz, Aysen
2016-06-01
Isparta city center is selected as a work area in this study because the public believes that the tap water is dirty and harmful. In this study, the city's drinking water in the distribution system and other spring waters which are used as drinking water in this region were investigated from the point of water quality and health risk assessment. Water samples were collected from major drinking water springs, tap waters, treatment plants and dam pond in the Isparta province center. Ca-Mg-HCO3, Mg-Ca-HCO3, Ca-Na-HCO3, Ca-HCO3, Ca-HCO3-SO4 and Ca-Mg-HCO3-SO4 are dominant water types. When compared to drinking water guidelines established by World Health Organization and Turkey, much greater attention should be paid to As, Br, Fe, F, NH4, PO4 through varied chemicals above the critical values. The increases of As, Fe, F, NH4 and PO4 are related to water-rock interaction. In tap waters, the increases of As and Fe are due to corrosion of pipes in drinking water distribution systems. The major toxic and carcinogenic chemicals within drinking water are As and Br for both tap water and spring water. Also, F is the non-carcinogenic chemical for only spring waters in the study area.
Fault tree analysis for integrated and probabilistic risk analysis of drinking water systems.
Lindhe, Andreas; Rosén, Lars; Norberg, Tommy; Bergstedt, Olof
2009-04-01
Drinking water systems are vulnerable and subject to a wide range of risks. To avoid sub-optimisation of risk-reduction options, risk analyses need to include the entire drinking water system, from source to tap. Such an integrated approach demands tools that are able to model interactions between different events. Fault tree analysis is a risk estimation tool with the ability to model interactions between events. Using fault tree analysis on an integrated level, a probabilistic risk analysis of a large drinking water system in Sweden was carried out. The primary aims of the study were: (1) to develop a method for integrated and probabilistic risk analysis of entire drinking water systems; and (2) to evaluate the applicability of Customer Minutes Lost (CML) as a measure of risk. The analysis included situations where no water is delivered to the consumer (quantity failure) and situations where water is delivered but does not comply with water quality standards (quality failure). Hard data as well as expert judgements were used to estimate probabilities of events and uncertainties in the estimates. The calculations were performed using Monte Carlo simulations. CML is shown to be a useful measure of risks associated with drinking water systems. The method presented provides information on risk levels, probabilities of failure, failure rates and downtimes of the system. This information is available for the entire system as well as its different sub-systems. Furthermore, the method enables comparison of the results with performance targets and acceptable levels of risk. The method thus facilitates integrated risk analysis and consequently helps decision-makers to minimise sub-optimisation of risk-reduction options.
Vulnerability of drinking water supplies to engineered nanoparticles.
Troester, Martin; Brauch, Heinz-Juergen; Hofmann, Thilo
2016-06-01
The production and use of engineered nanoparticles (ENPs) inevitably leads to their release into aquatic environments, with the quantities involved expected to increase significantly in the future. Concerns therefore arise over the possibility that ENPs might pose a threat to drinking water supplies. Investigations into the vulnerability of drinking water supplies to ENPs are hampered by the absence of suitable analytical methods that are capable of detecting and quantifiying ENPs in complex aqueous matrices. Analytical data concerning the presence of ENPs in drinking water supplies is therefore scarce. The eventual fate of ENPs in the natural environment and in processes that are important for drinking water production are currently being investigated through laboratory based-experiments and modelling. Although the information obtained from these studies may not, as yet, be sufficient to allow comprehensive assessment of the complete life-cycle of ENPs, it does provide a valuable starting point for predicting the significance of ENPs to drinking water supplies. This review therefore addresses the vulnerability of drinking water supplies to ENPs. The risk of ENPs entering drinking water is discussed and predicted for drinking water produced from groundwater and from surface water. Our evaluation is based on reviewing published data concerning ENP production amounts and release patterns, the occurrence and behavior of ENPs in aquatic systems relevant for drinking water supply and ENP removability in drinking water purification processes. Quantitative predictions are made based on realistic high-input case scenarios. The results of our synthesis of current knowledge suggest that the risk probability of ENPs being present in surface water resources is generally limited, but that particular local conditions may increase the probability of raw water contamination by ENPs. Drinking water extracted from porous media aquifers are not generally considered to be prone to ENP contamination. In karstic aquifers, however, there is an increased probability that if any ENPs enter the groundwater system they will reach the extraction point of a drinking water treatment plant (DWTP). The ability to remove ENPs during water treatment depends on the specific design of the treatment process. In conventional DWTPs with no flocculation step a proportion of ENPs, if present in the raw water, may reach the final drinking water. The use of ultrafiltration techniques improves drinking water safety with respect to ENP contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.
40 CFR 141.111 - Treatment techniques for acrylamide and epichlorohydrin.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Treatment Techniques § 141.111 Treatment techniques for acrylamide and epichlorohydrin. Each public water system must certify... and epichlorohydrin are used in drinking water systems, the combination (or product) of dose and...
Centralized Drinking Water Treatment Operations Shape Bacterial and Fungal Community Structure.
Ma, Xiao; Vikram, Amit; Casson, Leonard; Bibby, Kyle
2017-07-05
Drinking water microbial communities impact opportunistic pathogen colonization and corrosion of water distribution systems, and centralized drinking water treatment represents a potential control for microbial community structure in finished drinking water. In this article, we examine bacterial and fungal abundance and diversity, as well as the microbial community taxonomic structure following each unit operation in a conventional surface water treatment plant. Treatment operations drove the microbial composition more strongly than sampling time. Both bacterial and fungal abundance and diversity decreased following sedimentation and filtration; however, only bacterial abundance and diversity was significantly impacted by free chlorine disinfection. Similarly, each treatment step was found to shift bacterial and fungal community beta-diversity, with the exception of disinfection on the fungal community structure. We observed the enrichment of bacterial and fungal taxa commonly found in drinking water distribution systems through the treatment process, for example, Sphingomonas following filtration and Leptospirillium and Penicillium following disinfection. Study results suggest that centralized drinking water treatment processes shape the final drinking water microbial community via selection of community members and that the bacterial community is primarily driven by disinfection while the eukaryotic community is primarily controlled by physical treatment processes.
Regulatory Considerations to Ensure Clean and Safe Drinking Water
Federal drinking water regulations are based on risk assessment of human health effects and research conducted on source water, treatment technologies, residuals, and distribution systems. The book chapter summarizes the role that EPA research plays in ensuring pure drinking wat...
Schiavano, G F; Sisti, M; De Santi, M; Brandi, G
2006-01-01
Peracetic acid (PAA) is a disinfectant with a wide spectrum of antimicrobial activity, but little is known about the feasibility of using it in the field of drinking water treatment. The aim of this study has been assess disinfectant efficacy of PAA, alone or in combination with hypochlorite, against M. avium in drinking water M. avium is a common opportunistic pathogen in immunocompromised subjects that is able to survive and grow in drinking water distribution systems. In this study PAA did not show appreciable activity against the greater number of tested strains (16/21) up to 5 ppm of PAA, a weak activity was seen on 4 strains, while a significant reduction in viable cells (about 50%) was seen only on 1 strain after 48 h of treatment with 5 ppm of PAA. We also evidenced that M. avium was unaffected by chlorine concentration usually present in drinking water distribution system. Finally, the combination of PAA and sodium hypochlorite did not promote enhanced antimicrobial efficacy respect to the single disinfectants. In conclusion, our result would indicate that PAA is an unlikely candidate for the disinfection of drinking water from M. avium and further strategies are required to eliminate M. avium from drinking water system.
Trends in Drinking Water Nitrate Violations Across the United States
Drinking water maximum contaminant levels (MCL) are established by the U.S. EPA in order to protect human health. Since 1975, public water suppliers across the U.S. have reported violations of the MCL to the national Safe Drinking Water Information System (SDWIS). Nitrate is on...
Pollution of water sources and removal of pollutants by advanced drinking-water treatment in China.
Wang, L; Wang, B
2000-01-01
The pollution of water resources and drinking water sources in China is described in this paper with basic data. About 90% of surface waters and over 60% of drinking water sources in urban areas have been polluted to different extents. The main pollutants present in drinking water sources are organic substances, ammonia nitrogen, phenols, pesticides and pathogenic micro-organisms, some of which cannot be removed effectively by the traditional water treatment processes like coagulation, sedimentation, filtration and chlorination, and the product water usually does not meet Chinese national drinking water standards, when polluted source water is treated. In some drinking-water plants in China, advanced treatment processes including activated carbon filtration and adsorption, ozonation, biological activated carbon and membrane separation have been employed for further treatment of the filtrate from a traditional treatment system producing unqualified drinking water, to make final product water meet the WHO guidelines and some developed countries' standards, as well as the Chinese national standards for drinking water. Some case studies of advanced water treatment plants are described in this paper as well.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
... Public Comment and Public Hearing for Public Water System Supervision Program Revision for Virginia... revising its approved Public Water System Supervision Program. The Commonwealth has adopted the drinking... by reducing public water system consumers' risk of microbial illness from drinking water. EPA has...
Many US water utilities using chloramine as their secondary disinfectant have experienced nitrification episodes that detrimentally impact water quality in their distribution systems. A semi-closed pipe-loop chloraminated drinking water distribution system (DWDS) simulator was u...
The presentation entitled “Small Community and Household Water Systems Research on Removal of Metals and Pesticides from Drinking Water Sources” provides treatment alternatives for removal of metals and pesticides from surface and ground waters before human consumption. The pres...
40 CFR 141.100 - Criteria and procedures for public water systems using point-of-entry devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... water systems using point-of-entry devices. 141.100 Section 141.100 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER... meet all national primary drinking water regulations and would be of acceptable quality similar to...
Henke, A; Overath, H; Heinzke, J
1999-05-01
Monitoring the quality of drinking water is a cardinal task of German Public Health Offices and of the relevant Ministries of Health of the German Federal states ("Länder"). Today this can be tackled on a large scale and economically only with computer assistance. A system has been developed in North Rhine Westphalia on behalf of the Ministry of Health, for data assessment and communication which is suitable for practical work and user friendly. It aims at supporting the Public Health Offices in their daily work and at improving and simplifying the monitoring of drinking water supply systems and of drinking water quality control.
Chlorine stress mediates microbial surface attachment in drinking water systems.
Liu, Li; Le, Yang; Jin, Juliang; Zhou, Yuliang; Chen, Guowei
2015-03-01
Microbial attachment to drinking water pipe surfaces facilitates pathogen survival and deteriorates disinfection performance, directly threatening the safety of drinking water. Notwithstanding that the formation of biofilm has been studied for decades, the underlying mechanisms for the origins of microbial surface attachment in biofilm development in drinking water pipelines remain largely elusive. We combined experimental and mathematical methods to investigate the role of environmental stress-mediated cell motility on microbial surface attachment in chlorination-stressed drinking water distribution systems. Results show that at low levels of disinfectant (0.0-1.0 mg/L), the presence of chlorine promotes initiation of microbial surface attachment, while higher amounts of disinfectant (>1.0 mg/L) inhibit microbial attachment. The proposed mathematical model further demonstrates that chlorination stress (0.0-5.0 mg/L)-mediated microbial cell motility regulates the frequency of cell-wall collision and thereby controls initial microbial surface attachment. The results reveal that transport processes and decay patterns of chlorine in drinking water pipelines regulate microbial cell motility and, thus, control initial surface cell attachment. It provides a mechanistic understanding of microbial attachment shaped by environmental disinfection stress and leads to new insights into microbial safety protocols in water distribution systems.
RESPONDING TO THREATS AND INCIDENTS OF INTENTIONAL DRINKING WATER CONTAMINATION
All drinking water systems have some degree of vulnerability to contamination, and analysis shows that it is possible to contaminate drinking water at levels causing varying degrees of harm. Furthermore, experience indicates that the threat of contamination, overt or circumstant...
ERIC Educational Resources Information Center
Finks, Mason
1993-01-01
Provides information about home drinking water treatment systems to address concerns about the safety and quality of drinking water. Discusses water testing, filtration, product options and selection, water testing resources, water treatment device guidelines, water analysis terminology, and laboratory selection. (MCO)
Chemical quality and regulatory compliance of drinking water in Iceland.
Gunnarsdottir, Maria J; Gardarsson, Sigurdur M; Jonsson, Gunnar St; Bartram, Jamie
2016-11-01
Assuring sufficient quality of drinking water is of great importance for public wellbeing and prosperity. Nations have developed regulatory system with the aim of providing drinking water of sufficient quality and to minimize the risk of contamination of the water supply in the first place. In this study the chemical quality of Icelandic drinking water was evaluated by systematically analyzing results from audit monitoring where 53 parameters were assessed for 345 samples from 79 aquifers, serving 74 water supply systems. Compliance to the Icelandic Drinking Water Regulation (IDWR) was evaluated with regard to parametric values, minimum requirement of sampling, and limit of detection. Water quality compliance was divided according to health-related chemicals and indicators, and analyzed according to size. Samples from few individual locations were benchmarked against natural background levels (NBLs) in order to identify potential pollution sources. The results show that drinking compliance was 99.97% in health-related chemicals and 99.44% in indicator parameters indicating that Icelandic groundwater abstracted for drinking water supply is generally of high quality with no expected health risks. In 10 water supply systems, of the 74 tested, there was an indication of anthropogenic chemical pollution, either at the source or in the network, and in another 6 water supplies there was a need to improve the water intake to prevent surface water intrusion. Benchmarking against the NBLs proved to be useful in tracing potential pollution sources, providing a useful tool for identifying pollution at an early stage. Copyright © 2016 Elsevier GmbH. All rights reserved.
Bacterial populations were examined in a simulated chloraminated drinking water distribution system. After six months of continuous operation, coupons were incubated in CDC reactors receiving water from the simulated system to study biofilm development. The study was organized ...
Technical, Managerial and Financial (TMF) Capacity Resources for Small Drinking Water Systems
Resources are available to help public water systems build the technical, managerial and financial (TMF) capacity. TMF capacity is necessary to achieve and maintain long-term sustainability and compliance with national safe drinking water regulations.
On-line detection of Escherichia coli intrusion in a pilot-scale drinking water distribution system.
Ikonen, Jenni; Pitkänen, Tarja; Kosse, Pascal; Ciszek, Robert; Kolehmainen, Mikko; Miettinen, Ilkka T
2017-08-01
Improvements in microbial drinking water quality monitoring are needed for the better control of drinking water distribution systems and for public health protection. Conventional water quality monitoring programmes are not always able to detect a microbial contamination of drinking water. In the drinking water production chain, in addition to the vulnerability of source waters, the distribution networks are prone to contamination. In this study, a pilot-scale drinking-water distribution network with an on-line monitoring system was utilized for detecting bacterial intrusion. During the experimental Escherichia coli intrusions, the contaminant was measured by applying a set of on-line sensors for electric conductivity (EC), pH, temperature (T), turbidity, UV-absorbance at 254 nm (UVAS SC) and with a device for particle counting. Monitored parameters were compared with the measured E. coli counts using the integral calculations of the detected peaks. EC measurement gave the strongest signal compared with the measured baseline during the E. coli intrusion. Integral calculations showed that the peaks in the EC, pH, T, turbidity and UVAS SC data were detected corresponding to the time predicted. However, the pH and temperature peaks detected were barely above the measured baseline and could easily be mixed with the background noise. The results indicate that on-line monitoring can be utilized for the rapid detection of microbial contaminants in the drinking water distribution system although the peak interpretation has to be performed carefully to avoid being mixed up with normal variations in the measurement data. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yoder, Jonathan; Roberts, Virginia; Craun, Gunther F; Hill, Vincent; Hicks, Lauri A; Alexander, Nicole T; Radke, Vince; Calderon, Rebecca L; Hlavsa, Michele C; Beach, Michael J; Roy, Sharon L
2008-09-12
Since 1971, CDC, the U.S. Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have maintained a collaborative Waterborne Disease and Outbreak Surveillance System (WBDOSS) for collecting and reporting data related to occurrences and causes of waterborne-disease outbreaks (WBDOs) and cases of waterborne disease. This surveillance system is the primary source of data concerning the scope and effects of waterborne disease in the United States. Data presented summarize 28 WBDOs that occurred during January 2005--December 2006 and four previously unreported WBDOs that occurred during 1979--2002. The surveillance system includes data on WBDOs associated with recreational water, drinking water, water not intended for drinking (WNID) (excluding recreational water), and water use of unknown intent. Public health departments in the states, territories, localities, and Freely Associated States (FAS) (i.e., the Republic of the Marshall Islands, the Federated States of Micronesia, and the Republic of Palau, formerly parts of the U.S.-administered Trust Territory of the Pacific Islands) are primarily responsible for detecting and investigating WBDOs and voluntarily reporting them to CDC by a standard form. Only cases and outbreaks associated with drinking water, WNID (excluding recreational water), and water of unknown intent (WUI) are summarized in this report. Cases and outbreaks associated with recreational water are reported in a separate Surveillance Summary. Fourteen states reported 28 WBDOs that occurred during 2005--2006: a total of 20 were associated with drinking water, six were associated with WNID, and two were associated with WUI. The 20 drinking water-associated WBDOs caused illness among an estimated 612 persons and were linked to four deaths. Etiologic agents were identified in 18 (90.0%) of the drinking water-associated WBDOs. Among the 18 WBDOs with identified pathogens, 12 (66.7%) were associated with bacteria, three (16.7%) with viruses, two (11.1%) with parasites, and one (5.6%) mixed WBDO with both bacteria and viruses. In both WBDOs where the etiology was not determined, norovirus was the suspected etiology. Of the 20 drinking water WBDOs, 10 (50) were outbreaks of acute respiratory illness (ARI), nine (45%) were outbreaks of acute gastrointestinal illness (AGI), and one (5.0%) was an outbreak of hepatitis. All WBDOs of ARI were caused by Legionella, and this is the first reporting period in which the proportion of ARI WBDOs has surpassed that of AGI WBDOs since the reporting of Legionella WBDOs was initiated in 2001. A total of 23 deficiencies were cited in the 20 WBDOs associated with drinking water: 12 (52.2%) deficiencies fell under the classification NWU/POU (deficiencies occurred at points not under the jurisdiction of a water utility or at the point-of-use), 10 (43.5%) deficiencies fell under the classification SWTDs (contamination at or in the source water, treatment facility, or distribution system), and for one (4.3%) deficiency, classification was unknown. Among the 12 NWU/POU deficiencies, 10 (83.3%) involved Legionella spp. in the drinking water system. The most frequently cited SWTD deficiencies were associated with a treatment deficiency (n = four [40.0%]) and untreated ground water (n = four [40.0%]). Three of the four WBDOs with treatment deficiencies used ground water sources. Approximately half (52.2%) of the drinking water deficiencies occurred outside the jurisdiction of a water utility. The majority of these WBDOs were associated with Legionella spp, which suggests that increased attention should be targeted towards reducing illness risks associated with Legionella spp. Nearly all of WBDOs associated with SWTD deficiencies occurred in systems using ground water. EPA's new Ground Water Rule might prevent similar outbreaks in the future in public water systems. CDC and EPA use surveillance data to identify the types of water systems, deficiencies, and etiologic agents associated with WBDOs and to evaluate the adequacy of current technologies and practices for providing safe drinking water. Surveillance data also are used to establish research priorities, which can lead to improved water-quality regulation development. The majority of drinking water deficiencies are now associated with contamination at points outside the jurisdiction of public water systems (e.g., regrowth of Legionella spp. in hot water systems) and water contamination that might not be regulated by EPA (e.g., contamination of tap water at the POU). Improved education of consumers and plumbers might help address these risk factors.
Bacterial populations were examined in a simulated chloraminated drinking water distribution system. After six months of continuous operation, coupons were incubated in CDC reactors receiving water from the simulated system to study biofilm development. The distribution system ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j) Commission means the Nuclear... source of drinking water means an aquifer or its portion: (1)(i) Which supplies any public water system... supply a public water system; and (A) Currently supplies drinking water for human consumption; or (B...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j) Commission means the Nuclear... source of drinking water means an aquifer or its portion: (1)(i) Which supplies any public water system... supply a public water system; and (A) Currently supplies drinking water for human consumption; or (B...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j) Commission means the Nuclear... source of drinking water means an aquifer or its portion: (1)(i) Which supplies any public water system... supply a public water system; and (A) Currently supplies drinking water for human consumption; or (B...
AN OVERVIEW PRESENTATION OF USEPA AND USDA DRINKING WATER TREATMENT SYSTEM DEMONSTRATIONS IN CHINA
Under an interagency agreement with the US Department of Agriculture, US EPA is coordinating support for several water treatment research demonstrations in China. EPA has installed two small drinking water treatment technologies (a bottled water system for a small community and ...
AN OVERVIEW PAPER OF USEPA AND USDA DRINKING WATER TREATMENT SYSTEM DEMONSTRATIONS IN CHINA
Under an interagency agreement with the US Department of Agriculture, US EPA is coordinating support for several water treatment research demonstrations in China. EPA has installed two small drinking water treatment technologies (a bottled water system for a small community and ...
Particulate Arsenic Release in a Drinking Water Distribution System
Trace contaminants, such as arsenic, have been shown to accumulate in solids found in drinking water distribution systems. The obvious concern is that the contaminants in these solids could be released back into the water resulting in elevated levels in a consumer’s tap water. Th...
77 FR 34382 - Meetings of the National Drinking Water Advisory Council-Notice of Public Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
...The U.S. Environmental Protection Agency (EPA or agency) is announcing one public webinar/conference call and one in-person meeting of the National Drinking Water Advisory Council (NDWAC or Council), established under the Safe Drinking Water Act (SDWA). The Council will consider various issues associated with drinking water protection and public water systems. For the webinar/conference call, the Council will discuss a draft guidance for EPA permit writers relative to hydraulic fracturing using diesel fuels under the SDWA's Underground Injection Control (UIC) Program and also options for assisting small water systems in achieving sustainable practices. For the in-person meeting, the primary focus will be for the Council to discuss the proposed regulation of perchlorate under the SDWA. Also at this in-person meeting, the Council will discuss assistance to small water systems among other program issues.
[Investigation on acute nitrite poisoning in Yangjiang city, Guangdong province, China].
Yu, Hongjie; Luo, Huiming; Lu, Xirong; Song, Qubo; Fan, Zifan
2002-12-01
To determine the cause of acute poisoning occurred in a factory in Yangjiang city, Guangdong province. In a cross-sectional study, interviews were conducted with the administrators of the factory and the local physician. A review was conducted on the water system used for industrial purposes and a separate system used by workers for drinking water. Treatment and discharge of industrial waste water were examined. Face-to-face interview was conducted to identify risk of exposure for illness among workers. A total number of 36 cases were identified in the plant and the attack rate was 16.4% (36/220). The incubation period (time between drinking polluted water and the onset of symptoms) had a median of 90 minutes (range: 30 - 230 minutes). Consuming water at the factory increased the attack rate and a dose-response effect was identified (chi(2)(trend) = 79.115, P < 0.01). The nitrite content of residuals in drinking water exceeded the WHO standard (1 ppm). The accident of acute poisoning was due to drinking water contaminated with sodium nitrite. The prevention of drinking water contaminated by toxic chemicals like sodium nitrite, and the design of industrial and potable water supply system need to be carefully reviewed. Regulations should be developed and enforced to minimize the impact of industrial waste water discharges to guarantee the access to clean drinking water.
Drinking water supplies can be vulnerable to impacts from short-term weather events, long-term changes in land-use and climate, and water quality controls in treatment and distribution. Disinfection by-product (DBP) formation in drinking water is a prominent example to illustrate...
Drinking water supplies can be vulnerable to impacts from short-term weather events, long-term changes in land-use and climate, and water quality controls in treatment and distribution. Disinfection by-product (DBP) formation in drinking water is a prominent example to illustrate...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
... persons and from American Indian and Alaskan Native Village community water systems and not-for-profit non... Activities: Submission to OMB for Review and Approval; Comment Request; 2011 Drinking Water Infrastructure...: Robert Barles, Drinking Water Protection Division (Mail Code 4606M), Office of Ground Water and Drinking...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-05
... developmental health risks from disinfection byproducts in drinking water and by reducing illness linked with... 1413 of the Safe Drinking Water Act, as amended, and the requirements governing the National Primary Drinking Water Regulations Implementation, 40 CFR part 142, that the Commonwealth of Virginia is revising...
78 FR 67361 - Public Water System Supervision Program Revision for the Commonwealth of Kentucky
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-12
... Drinking Water Branch, 61 Forsyth Street SW., Atlanta, Georgia 30303. FOR FURTHER INFORMATION CONTACT: Mr. Brian Thames, the EPA Region 4, Safe Drinking Water Branch, at the address given above, by telephone at... Kentucky submitted requests that the Region approve revisions to the Commonwealth's Safe Drinking Water Act...
Unregulated Drinking Water Systems.
Farquhar, Doug
2018-02-01
(1)One in 9 Americans gets his or her drinking water from a private well. (2) An estimated 20 percent of private wells have contaminants above Environmental Protection Agency drinking water standards.(3) Disease outbreaks from private wells are increasing, according to the Centers for Disease Control and Prevention.
78 FR 9047 - Public Water System Supervision Program Revision for the State of Texas
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-07
... Water System Supervision Program. Texas has adopted three EPA drinking water rules, namely the: (1) Long Term 2 Enhanced Surface Water Treatment Rule (LT2), (2) the Stage 2 Disinfectants and Disinfection... Drinking Water Section (MC-155), Building F, 12100 Park 35 Circle, Austin, TX 78753; and United States...
78 FR 73858 - Public Water System Supervision Program Revision for the State of Oklahoma
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-09
... approved Public Water System Supervision Program. Oklahoma has adopted three EPA drinking water rules... and Disinfection Byproducts Rule (DBP2), and (3) the Ground Water Rule (GWR). EPA has determined that... Protection Agency, Region 6, Drinking Water Section (6WQ-SD), 1445 Ross Avenue, Suite 1200, Dallas, Texas...
Turgeon, Steve; Rodriguez, Manuel J; Thériault, Marius; Levallois, Patrick
2004-04-01
The purpose of every water utility is to provide consumers with drinking water that is aesthetically acceptable and presents no risk to public health. Several studies have been carried out to analyze people's perception and attitude about the drinking water coming from their water distribution systems. The goal of the present study is to investigate the influence of water quality and the geographic location of consumers within a distribution system on consumer perception of tap water. The study is based on the data obtained from two surveys carried out in municipalities of the Quebec City area (Canada). Three perception variables were used to study consumer perception: general satisfaction, taste satisfaction and risk perception. Data analysis based on logistic regression indicates that water quality variations and geographic location in the distribution system have a significant impact on the consumer perception. This impact appears to be strongly associated with residual chlorine levels. The study also confirms the importance of socio-economic characteristics of consumers on their perception of drinking water quality.
Increasingly, drinking water treatment plants (DWTPs) are being challenged by changes in the quality of their source waters and by their aging treatment and distribution system infrastructure. Individually or in combination, factors such as shrinking water and financial resources...
Corrosion of iron pipes in Drinking Water Distribution Systems (DWDS) contributes to the formation of tubercles whose physio-chemical properties are influenced by the composition of the waters in the distribution system. Thus the objective of this study was to assess the extent o...
Bacterial populations were examined in a simulated chloraminated drinking water distribution system (i.e. PVC pipe loop). After six months of continuous operation, coupons were incubated in CDC reactors receiving water from the simulated system to study biofilm development. The s...
The presence of contaminants in a drinking water distribution system can result in exposure of consumers to contaminated water. Whether the contaminants result from waterborne outbreaks that accidentally enter the system or through purposeful acts, the movement of the resulting ...
Deficiencies in drinking water distribution systems in developing countries.
Lee, Ellen J; Schwab, Kellogg J
2005-06-01
Rapidly growing populations and migration to urban areas in developing countries has resulted in a vital need for the establishment of centralized water systems to disseminate potable water to residents. Protected source water and modern, well-maintained drinking water treatment plants can provide water adequate for human consumption. However, ageing, stressed or poorly maintained distribution systems can cause the quality of piped drinking water to deteriorate below acceptable levels and pose serious health risks. This review will outline distribution system deficiencies in developing countries caused by: the failure to disinfect water or maintain a proper disinfection residual; low pipeline water pressure; intermittent service; excessive network leakages; corrosion of parts; inadequate sewage disposal; and inequitable pricing and usage of water. Through improved research, monitoring and surveillance, increased understanding of distribution system deficiencies may focus limited resources on key areas in an effort to improve public health and decrease global disease burden.
Chemical Contamination of California Drinking Water
Russell, Hanafi H.; Jackson, Richard J.; Spath, David P.; Book, Steven A.
1987-01-01
Drinking water contamination by toxic chemicals has become widely recognized as a public health concern since the discovery of 1,2-dibromo-3-chloropropane in California's Central Valley in 1979. Increased monitoring since then has shown that other pesticides and industrial chemicals are present in drinking water. Contaminants of drinking water also include naturally occurring substances such as asbestos and even the by-products of water chlorination. Public water systems, commercially bottled and vended water and mineral water are regulated, and California is also taking measures to prevent water pollution by chemicals through various new laws and programs. PMID:3321714
Chemical contamination of California drinking water.
Russell, H H; Jackson, R J; Spath, D P; Book, S A
1987-11-01
Drinking water contamination by toxic chemicals has become widely recognized as a public health concern since the discovery of 1,2-dibromo-3-chloropropane in California's Central Valley in 1979. Increased monitoring since then has shown that other pesticides and industrial chemicals are present in drinking water. Contaminants of drinking water also include naturally occurring substances such as asbestos and even the by-products of water chlorination. Public water systems, commercially bottled and vended water and mineral water are regulated, and California is also taking measures to prevent water pollution by chemicals through various new laws and programs.
Endocrine disrupting compounds in drinking water supply system and human health risk implication.
Wee, Sze Yee; Aris, Ahmad Zaharin
2017-09-01
To date, experimental and epidemiological evidence of endocrine disrupting compounds (EDCs) adversely affecting human and animal populations has been widely debated. Notably, human health risk assessment is required for risk mitigation. The lack of human health risk assessment and management may thus unreliably regulate the quality of water resources and efficiency of treatment processes. Therefore, drinking water supply systems (DWSSs) may be still unwarranted in assuring safe access to potable drinking water. Drinking water supply, such as tap water, is an additional and crucial route of human exposure to the health risks associated with EDCs. A holistic system, incorporating continuous research in DWSS monitoring and management using multi-barrier approach, is proposed as a preventive measure to reduce human exposure to the risks associated with EDCs through drinking water consumption. The occurrence of EDCs in DWSSs and corresponding human health risk implications are analyzed using the Needs, Approaches, Benefits, and Challenges (NABC) method. Therefore, this review may act as a supportive tool in protecting human health and environmental quality from EDCs, which is essential for decision-making regarding environmental monitoring and management purposes. Subsequently, the public could have sustainable access to safer and more reliable drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bereskie, Ty; Rodriguez, Manuel J.; Sadiq, Rehan
2017-08-01
Drinking water management in Canada is complex, with a decentralized, three-tiered governance structure responsible for safe drinking water throughout the country. The current approach has been described as fragmented, leading to governance gaps, duplication of efforts, and an absence of accountability and enforcement. Although there have been no major waterborne disease outbreaks in Canada since 2001, a lack of performance improvement, especially in small drinking water systems, is evident. The World Health Organization water safety plan approach for drinking water management represents an alternative preventative management framework to the current conventional, reactive drinking water management strategies. This approach has seen successful implementation throughout the world and has the potential to address many of the issues with drinking water management in Canada. This paper presents a review and strengths-weaknesses-opportunities-threats analysis of drinking water management and governance in Canada at the federal, provincial/territorial, and municipal levels. Based on this analysis, a modified water safety plan (defined as the plan-do-check-act (PDCA)-WSP framework) is proposed, established from water safety plan recommendations and the principles of PDCA for continuous performance improvement. This proposed framework is designed to strengthen current drinking water management in Canada and is designed to fit within and incorporate the existing governance structure.
Bereskie, Ty; Rodriguez, Manuel J; Sadiq, Rehan
2017-08-01
Drinking water management in Canada is complex, with a decentralized, three-tiered governance structure responsible for safe drinking water throughout the country. The current approach has been described as fragmented, leading to governance gaps, duplication of efforts, and an absence of accountability and enforcement. Although there have been no major waterborne disease outbreaks in Canada since 2001, a lack of performance improvement, especially in small drinking water systems, is evident. The World Health Organization water safety plan approach for drinking water management represents an alternative preventative management framework to the current conventional, reactive drinking water management strategies. This approach has seen successful implementation throughout the world and has the potential to address many of the issues with drinking water management in Canada. This paper presents a review and strengths-weaknesses-opportunities-threats analysis of drinking water management and governance in Canada at the federal, provincial/territorial, and municipal levels. Based on this analysis, a modified water safety plan (defined as the plan-do-check-act (PDCA)-WSP framework) is proposed, established from water safety plan recommendations and the principles of PDCA for continuous performance improvement. This proposed framework is designed to strengthen current drinking water management in Canada and is designed to fit within and incorporate the existing governance structure.
Many water utilities in the US using chloramine as disinfectant treatment in their distribution systems have experienced nitrification episodes, which detrimentally impact the water quality. Here, we used 16S rRNA sequencing data to generate high-resolution taxonomic profiles of...
Field Testing of a Small Water Purification System for Non-PRASA Rural Communities
Small, rural communities typically do not have adequate water purification systems to sustain their life quality and residents are exposed to pathogens present in drinking water. In Puerto Rico (PR), approximately 4% of the population does not have access to drinking water provi...
Optoelectronic and other conventional water quality sensors offer a potential for real-time online detection of chemical and biological contaminants in a drinking water supply and distribution system. The nature of the application requires sensors of detection capabilities at lo...
Electrochemical alternatives for drinking water disinfection.
Martínez-Huitle, Carlos A; Brillas, Enric
2008-01-01
Chlorination is the most common method worldwide for the disinfection of drinking water. However, the identification of potentially toxic products from this method has encouraged the development of alternative disinfection technologies. Among them, electrochemical disinfection has emerged as one of the more feasible alternatives to chlorination. This article reviews electrochemical systems that can contribute to drinking water disinfection and underscores the efficiency of recently developed diamond films in chlorine-free electrochemical systems.
Report #2006-P-00011, February 14, 2006. The Mississippi Department of Health and drinking water system operators provided the public with timely and accurate information about the safety and proper treatment of public drinking water supplies.
Drinking Water - National Drinking Water Clearinghouse
relevant to drinking water issues. We provide free and low-cost publications, products, databases , referrals, and more. Free Technical Assistance Calls The NDWC can answer common questions involving issues system troubleshooting. Call our Engineers and technical assistance specialists toll-free at (304) 293
INACTIVATION OF BIOLOGICAL CONTAMINANTS IN DRINKING WATER IN RESPONSE TO A TERRORIST ATTACK
In the event of an intentional biological contamination of a drinking water treatment and distribution system, information on the removal and/or inactivation of known biological agents by drinking water treatment processes is needed. This project was initiated to determine what i...
National trends in drinking water quality violations.
Allaire, Maura; Wu, Haowei; Lall, Upmanu
2018-02-27
Ensuring safe water supply for communities across the United States is a growing challenge in the face of aging infrastructure, impaired source water, and strained community finances. In the aftermath of the Flint lead crisis, there is an urgent need to assess the current state of US drinking water. However, no nationwide assessment has yet been conducted on trends in drinking water quality violations across several decades. Efforts to reduce violations are of national concern given that, in 2015, nearly 21 million people relied on community water systems that violated health-based quality standards. In this paper, we evaluate spatial and temporal patterns in health-related violations of the Safe Drinking Water Act using a panel dataset of 17,900 community water systems over the period 1982-2015. We also identify vulnerability factors of communities and water systems through probit regression. Increasing time trends and violation hot spots are detected in several states, particularly in the Southwest region. Repeat violations are prevalent in locations of violation hot spots, indicating that water systems in these regions struggle with recurring issues. In terms of vulnerability factors, we find that violation incidence in rural areas is substantially higher than in urbanized areas. Meanwhile, private ownership and purchased water source are associated with compliance. These findings indicate the types of underperforming systems that might benefit from assistance in achieving consistent compliance. We discuss why certain violations might be clustered in some regions and strategies for improving national drinking water quality.
The drinking water distribution system simulator (DSS) from the U.S. EPA was operated with a direct cross-connection of 0.3% wastewater to system volume per day for 70 d. During the cross-connection, tap water, wastewater, and system discharge water were monitored to ensure that ...
Performance of pond-wetland complexes as a preliminary processor of drinking water sources.
Wang, Weidong; Zheng, Jun; Wang, Zhongqiong; Zhang, Rongbin; Chen, Qinghua; Yu, Xinfeng; Yin, Chengqing
2016-01-01
Shijiuyang Constructed Wetland (110 hm(2)) is a drinking water source treatment wetland with primary structural units of ponds and plant-bed/ditch systems. The wetland can process about 250,000 tonnes of source water in the Xincheng River every day and supplies raw water for Shijiuyang Drinking Water Plant. Daily data for 28 months indicated that the major water quality indexes of source water had been improved by one grade. The percentage increase for dissolved oxygen and the removal rates of ammonia nitrogen, iron and manganese were 73.63%, 38.86%, 35.64%, and 22.14% respectively. The treatment performance weight of ponds and plant-bed/ditch systems was roughly equal but they treated different pollutants preferentially. Most water quality indexes had better treatment efficacy with increasing temperature and inlet concentrations. These results revealed that the pond-wetland complexes exhibited strong buffering capacity for source water quality improvement. The treatment cost of Shijiuyang Drinking Water Plant was reduced by about 30.3%. Regional rainfall significantly determined the external river water levels and adversely deteriorated the inlet water quality, thus suggesting that the "hidden" diffuse pollution in the multitudinous stream branches as well as their catchments should be the controlling emphases for river source water protection in the future. The combination of pond and plant-bed/ditch systems provides a successful paradigm for drinking water source pretreatment. Three other drinking water source treatment wetlands with ponds and plant-bed/ditch systems are in operation or construction in the stream networks of the Yangtze River Delta and more people will be benefited. Copyright © 2015. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vartiainen, T.; Lampelo, S.
The mutagenicity of chlorinated drinking waters processed from humus-rich surface waters has been shown to be very high. The effect of placental S9 on the mutagenicity of drinking waters has not been studied previously. The purpose of this study was to compare the effects of human placental and rat liver microsomal fractions on the mutagenicity of drinking waters processed from humus-rich surface waters. The samples of 34 drinking and two raw waters from 26 localities in Finland were tested for mutagenicity in Ames Salmonella typhimurium tester strain TA100 with and without metabolic activations. Between the drinking water samples, clear differencesmore » were recorded in the presence of placental and rat liver S9, suggesting different mutagens in the drinking waters. Rat liver S9 decreased the mutagenicities of drinking water concentrates, but placental S9 increased, decreased, or had no effect. It is not known if placental mutagenicity enhancing system might cause any health hazard to a developing fetus.« less
Trends in the occurrence of MTBE in drinking water in the Northeast United States
Moran, M.J.
2007-01-01
Public water systems in Connecticut, Maine, Maryland, New Hampshire, New Jersey, and Rhode Island sampled treated drinking water from 1993-2006 and analyzed the samples for MTBE. The US Geological Survey examined trends in the occurrence of MTBE in drinking water derived from ground water in these States for two near-decadal time steps; 1993-1999 and 2000-2006. MTBE was detected in 14% of drinking water samples collected in all States from 1993-1999 and in 19% of drinking water samples collected from the same systems from 2000-2006 and this difference was statistically significant. Trends in the occurrence of MTBE in each State by individual year indicated significant positive trends in Maryland and New Hampshire. Significant, increasing trends in MTBE concentrations were observed in Maryland and Rhode Island by individual year. This is an abstract of a paper presented at the 2007 Petroleum Hydrocarbons and Organic Chemicals in Ground Water: Prevention, Assessment and Remediation Conference (Houston, TX 11/5-6/2007).
APPLICATION OF USEPA'S DRINKING WATER REGULATIONS TOWARDS RAINWATER CATCHMENT SYSTEMS
Rainwater harvesting is receiving increased attention worldwide as an alternative source of drinking water. Although federal agencies such as the USEPA acknowledge the existence of rainwater collection systems, the monitoring of this water source is still typically carried out b...
The Accumulation of Radioactive Contaminants in Drinking Water Distribution Systems
The accumulation of trace contaminants in drinking water distribution systems has been documented and the subsequent release of the contaminants back to the water is a potential exposure pathway. Radioactive contaminants are of particular concern because of their known health eff...
Bacterial populations were examined in a simulated chloraminated drinking water distribution system. After six months of continuous operation, coupons were incubated in CDC reactors receiving water from the simulated system to study biofilm development. The distribution system wa...
DeSilva, M B; Schafer, S; Kendall Scott, M; Robinson, B; Hills, A; Buser, G L; Salis, K; Gargano, J; Yoder, J; Hill, V; Xiao, L; Roellig, D; Hedberg, K
2016-01-01
Cryptosporidium, a parasite known to cause large drinking and recreational water outbreaks, is tolerant of chlorine concentrations used for drinking water treatment. Human laboratory-based surveillance for enteric pathogens detected a cryptosporidiosis outbreak in Baker City, Oregon during July 2013 associated with municipal drinking water. Objectives of the investigation were to confirm the outbreak source and assess outbreak extent. The watershed was inspected and city water was tested for contamination. To determine the community attack rate, a standardized questionnaire was administered to randomly sampled households. Weighted attack rates and confidence intervals (CIs) were calculated. Water samples tested positive for Cryptosporidium species; a Cryptosporidium parvum subtype common in cattle was detected in human stool specimens. Cattle were observed grazing along watershed borders; cattle faeces were observed within watershed barriers. The city water treatment facility chlorinated, but did not filter, water. The community attack rate was 28·3% (95% CI 22·1-33·6), sickening an estimated 2780 persons. Watershed contamination by cattle probably caused this outbreak; water treatments effective against Cryptosporidium were not in place. This outbreak highlights vulnerability of drinking water systems to pathogen contamination and underscores the need for communities to invest in system improvements to maintain multiple barriers to drinking water contamination.
75 FR 69662 - Public Water System Supervision Program Revision for the State of Colorado
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
... accordance with the provisions of section 1413 of the Safe Drinking Water Act (SDWA), 42 U.S.C. 300g-2, and... Short Term Regulatory Revisions which correspond to the National Primary Drinking Water Regulations..., Drinking Water Program, 1595 Wynkoop Street, Denver, CO 80202-1129, (2) Colorado Department of Public...
: EPA Region 6, in collaboration with the Office of Research and Development and Office of Water (OW) in Cincinnati, Ohio, and the Louisiana Department of Health and Hospitals (LDHH), proposes a drinking water research project to understand how maintaining various drinking water...
77 FR 23246 - Public Water System Supervision Program Revision for the Commonwealth of Kentucky
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-18
... 40601; and the U.S. Environmental Protection Agency, Region 4, Safe Drinking Water Branch, 61 Forsyth... Drinking Water Branch, at the address given above, by telephone at (404) 562-9845, or at [email protected] . Authority: Section 1413 of the Safe Drinking Water Act, as amended (1996), and 40 CFR part 142...
EPA requires drinking water utilities to monitor source water to determine the need for treatment to remove the precursors (natural organic matter {NOM}) of disinfection by-products (DBPs). Currently, drinking water utilities use total organic carbon (TOC), dissolved organic car...
López-Roldán, Ramón; Rubalcaba, Alicia; Martin-Alonso, Jordi; González, Susana; Martí, Vicenç; Cortina, Jose Luis
2016-01-01
A methodology has been developed in order to evaluate the potential risk of drinking water for the health of the consumers. The methodology used for the assessment considered systemic and carcinogenic effects caused by oral ingestion of water based on the reference data developed by the World Health Organisation (WHO) and the Risk Assessment Information System (RAIS) for chemical contaminants. The exposure includes a hypothetical dose received by drinking this water according to the analysed contaminants. An assessment of the chemical quality improvement of produced water in the Drinking Water Treatment Plant (DWTP) after integration of membrane technologies was performed. Series of concentration values covering up to 261 chemical parameters over 5 years (2008-2012) of raw and treated water in the Sant Joan Despí DWTP, at the lower part of the Llobregat River basin (NE Spain), were used. After the application of the methodology, the resulting global indexes were located below the thresholds except for carcinogenic risk in the output of DWTP, where the index was slightly above the threshold during 2008 and 2009 before the upgrade of the treatment works including membrane technologies was executed. The annual evolution of global indexes showed a reduction in the global values for all situations: HQ systemic index based on RAIS dropped from 0.64 to 0.42 for surface water and from 0.61 to 0.31 for drinking water; the R carcinogenic index based on RAIS was negligible for input water and varied between 4.2×10(-05) and 7.4×10(-06) for drinking water; the W systemic index based on the WHO data varied between 0.41 and 0.16 for surface water and between 0.61 and 0.31 for drinking water. A specific analysis for the indexes associated with trihalomethanes (THMs) showed the same pattern. Copyright © 2015 Elsevier B.V. All rights reserved.
Koskinen, R; Ali-Vehmas, T; Kämpfer, P; Laurikkala, M; Tsitko, I; Kostyal, E; Atroshi, F; Salkinoja-Salonen, M
2000-10-01
Sphingomonas species were commonly isolated from biofilms in drinking water distribution systems in Finland (three water meters) and Sweden (five water taps in different buildings). The Sphingomonas isolates (n = 38) were characterized by chemotaxonomic, physiological and phylogenetic methods. Fifteen isolates were designated to species Sphingomonas aromaticivorans, seven isolates to S. subterranea, two isolates to S. xenophaga and one isolate to S. stygia. Thirteen isolates represented one or more new species of Sphingomonas. Thirty-three isolates out of 38 grew at 5 degrees C on trypticase soy broth agar (TSBA) and may therefore proliferate in the Nordic drinking water pipeline where the temperature typically ranges from 2 to 12 degrees C. Thirty-three isolates out of 38 grew at 37 degrees C on TSBA and 15 isolates also grew on blood agar at 37 degrees C. Considering the potentially pathogenic features of sphingomonas, their presence in drinking water distribution systems may not be desirable.
NASA Astrophysics Data System (ADS)
Bespalov, Yurii G.; Nosov, Konstantin V.; Vysotska, Olena V.; Porvan, Andrii P.; Omiotek, Zbigniew; Burlibay, Aron; Assembay, Azat; Szatkowska, Małgorzata
2017-08-01
This study aims at mathematical modeling of systemic factors threatening the sanitary and hygienic state of sources of water supply. It is well-known, that this state affects health of population consuming water from different water sources (lakes, reservoirs, rivers). In particular, water quality problem may cause allergic reactions that are the important problem of health care. In the paper, the authors present the mathematical model, that enables on the basis of observations of a natural system to predict the system's behavior and determine the risks related to deterioration of drinking water resources. As a case study, we uses supply of drinking water from Lake Sevan, but the approach developed in the study can be applied to wide area of adjacent problems.
Where this occurs: Ground Water and Drinking Water
As ground water works its way through the soil, it can pick up excess nutrients and transport them to the water table. When polluted groundwater reaches drinking water systems it can pose serious public health threats.
Environmental Protection Agency rules stipulate that corrective action be taken for drinking water distribution systems that exceed the maximum contaminant level (MCL) for total Trihalomethanes (TTHMs) 80μg/L. Real-time, or even periodic, monitoring of drinking water i...
The Accumulation Of Radium And Other Radionuclides In Drinking Water Distribution Systems
The tendency for iron solid surfaces to adsorb trace contaminants such as arsenic is well known and has become the basis for several drinking water treatment approaches. It is reasonable to assume that iron-based solids, such as corrosion deposits present in drinking water distr...
Background: Current evidence suggests that drinking water, soil, and produce are potential sources of Mycobacterium avium infections, a pathogen not known to be transmitted person-to-person.
Methods: We sampled water during 2000 - 2002 from a large municipal drinking wate...
Legionella persistence and amplification in premise drinking water systems is a known contributor to legionellosis outbreaks, especially in the presence of suitable eukaryotic hosts. Here we examined Legionella pneumophila behavior within drinking water biofilms grown on copper ...
40 CFR 141.210 - Notice by primacy agency on behalf of the public water system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Notice by primacy agency on behalf of the public water system. 141.210 Section 141.210 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Public Notification of Drinking Water Violations § 141.210...
NASA Astrophysics Data System (ADS)
Harun, M. A. Y. A.; Kabir, G. M. M.
2013-03-01
This study investigates existing water supply scenario, and evaluates the performance of pond sand filter (PSF) in meeting drinking water demand of Dacope Upazila in southwest coastal Bangladesh. Questionnaire survey to the villagers reveals that PSF is the major drinking water sources (38 %) of the study area followed by tubewells (30.4 %), rainwater harvesting (RWH) systems (12.6 %), ponds (10.3 %) and others (8.7 %). The spot test and laboratory analysis show that odour, colour, pH, dissolved oxygen, hardness, calcium, magnesium, nitrate, sulphate and phosphate of the PSFs water meet Bangladesh standard. The efficiency of PSF in reducing total dissolved solids (TDS) (15 %) and potassium (8.2 %) is not enough to meet the standard of 20 % PSFs for TDS and one-third PSFs for potassium. The study proves that PSF is unable to remove coliform bacteria by 100 % from highly contaminated water. Hence, disinfection should be adopted before distribution to ensure safe drinking water. Majority of the PSF's users (80 %) are either partially satisfied or dissatisfied with the existing system. The beneficiary's willingness to pay for drinking water technologies seems that the combination of PSF and RWH could ensure sustainable drinking water in coastal region of Bangladesh.
Monochloramine Cometabolism by Mixed-Culture Nitrifiers ...
The current research investigated monochloramine cometabolism by nitrifying mixed cultures grown under drinking water relevant conditions and harvested from sand-packed reactors before conducting suspended growth batch kinetic experiments. Three batch reactors were used in each experiment: (1) a positive control to estimate ammonia kinetic parameters, (2) a negative control to account for abiotic reactions, and (3) a cometabolism reactor to estimate cometabolism kinetic constants. Kinetic parameters were estimated in AQUASIM with a simultaneous fit to all experimental data. Cometabolism kinetics were best described by a first order model. Monochloramine cometabolism kinetics were similar to those of ammonia metabolism, and monochloramine cometabolism was a significant loss mechanism (30% of the observed monochloramine loss). These results demonstrated that monochloramine cometabolism occurred in mixed cultures similar to those found in drinking water distribution systems; thus, cometabolism may be a significant contribution to monochloramine loss during nitrification episodes in drinking water distribution systems. The results demonstrated that monochloramine cometabolism occurred in mixed cultures similar to those found in drinking water distribution systems; thus, cometabolism may be a significant contribution to monochloramine loss during nitrification episodes in drinking water distribution systems.
We report the draft genome of two Sphingopyxis spp. strains isolated from a chloraminated drinking water distribution system simulator. Both strains are ubiquitous residents and early colonizers of water distribution systems. Genomic annotation identified a class 1 integron (in...
[The occurrence of aeromonads in a drinking water supply system].
Stelzer, W; Jacob, J; Feuerpfeil, I; Schulze, E
1992-01-01
This study concerns with the occurrence of aeromonads, coliforms and colony counts in a drinking water supply. Aeromonas contents were detected in the range of 15.0 to greater than 2,400/100 ml in the raw water samples of the man made lake. After the drinking water treatment process including fast sand filtration and chlorination aeromonads indicated in comparison to total coliforms and colony counts early and significant an after-growth of maximal 240 aeromonads/100 ml in the peripheric drinking water supply. Drinking water samples characterized by a higher water temperature resulted in the highest contents of aeromonads. The Aeromonas-Species Aeromonas sobria and Aeromonas hydrophila were isolated most frequently with 56.9 and 37.4 percent, respectively. The role of aeromonads as an indicator of after-growth in drinking water supplies is discussed.
Drinking Water State Revolving Fund National Information Management System Reports
The Drinking Water State Revolving Fund (DWSRF) National Information Management System collects information that provide a record of progress and accountability for the program at both the State and National level.
FINANCING ASSISTANCE AVAILABLE FOR SMALL PUBLIC WATER SYSTEMS
Many small and very small drinking water systems require repair and upgrading if they are to comply with the Safe Drinking Water Act of 1974 and its amendments. Often, dispersed population makes infracstructure expensive on a per-capita basis. Funding shortages at the federal, ...
USEPA'S RESEARCH EFFORTS IN SMALL DRINKING WATER TREATMENT TECHNOLOGIES
Currently, in the United States there are approximately 50,000 small community and 130,000 non-community systems providing water to over 25 million people. The drinking water treatment systems at these locations are not always adequate to comply with current and pending regulati...
Spatial and temporal analogies in microbial communities in natural drinking water biofilms.
Douterelo, I; Jackson, M; Solomon, C; Boxall, J
2017-03-01
Biofilms are ubiquitous throughout drinking water distribution systems (DWDS), playing central roles in system performance and delivery of safe clean drinking water. However, little is known about how the interaction of abiotic and biotic factors influence the microbial communities of these biofilms in real systems. Results are presented here from a one-year study using in situ sampling devices installed in two operational systems supplied with different source waters. Independently of the characteristics of the incoming water and marked differences in hydraulic conditions between sites and over time, a core bacterial community was observed in all samples suggesting that internal factors (autogenic) are central in shaping biofilm formation and composition. From this it is apparent that future research and management strategies need to consider the specific microorganisms found to be able to colonise pipe surfaces and form biofilms, such that it might be possible to exclude these and hence protect the supply of safe clean drinking water. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
the passage of the US SDWA in 1974 has had a major impact on the way water is treated and delivered in the US. The Act established national drinking water regulations for more than 170,000 public drinking water systems serving over 250 million people in the US. Under the SDWA pub...
Safe drinking water in regional NSW, Australia.
Byleveld, Paul M; Leask, Sandy D; Jarvis, Leslie A; Wall, Katrina J; Henderson, Wendy N; Tickell, Joshua E
2016-04-15
The New South Wales (NSW) Public Health Act 2010 requires water suppliers to implement a drinking water quality assurance program that addresses the 'Framework for management of drinking water quality' in the Australian drinking water guidelines. NSW Health has recognised the importance of a staged implementation of this requirement and the need to support regional water utilities. To date, NSW Health has assisted 74 regional utilities to develop and implement their management systems. The Public Health Act 2010 has increased awareness of drinking water risk management, and offers a systematic process to identify and control risks. This has benefited large utilities, smaller suppliers, and remote and Aboriginal communities. Work is continuing to ensure implementation of the process by private suppliers and water carters.
Hou, Dibo; Song, Xiaoxuan; Zhang, Guangxin; Zhang, Hongjian; Loaiciga, Hugo
2013-07-01
An event-driven, urban, drinking water quality early warning and control system (DEWS) is proposed to cope with China's urgent need for protecting its urban drinking water. The DEWS has a web service structure and provides users with water quality monitoring functions, water quality early warning functions, and water quality accident decision-making functions. The DEWS functionality is guided by the principles of control theory and risk assessment as applied to the feedback control of urban water supply systems. The DEWS has been deployed in several large Chinese cities and found to perform well insofar as water quality early warning and emergency decision-making is concerned. This paper describes a DEWS for urban water quality protection that has been developed in China.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
... at Potomac Yards South, first floor conference room located at 2777 South Crystal Drive Arlington, VA... Water and Drinking Water, U.S. Environmental Protection Agency; telephone (202) 564-4901 or by email to... from States, small publicly owned water systems, local public health officials, drinking water...
"Colored water" describes the appearance of drinking water that contains suspended particulate iron although the actual suspension color may be light yellow to red depending on water chemistry and particle properties. The release of iron from distribution system materials such a...
Colored water" describes the appearance of drinking water that contains suspended particulate iron although the actual suspension color may be light yellow to red depending on water chemistry and particle properties. The release of iron from distribution system materials such as...
Methods for detecting total coliform bacteria in drinking water were compared using 1483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a ten tube fermentation tube tech...
Uejio, Christopher K; Yale, Steven H; Malecki, Kristen; Borchardt, Mark A; Anderson, Henry A; Patz, Jonathan A
2014-04-01
This study investigated if the type of drinking water source (treated municipal, untreated municipal, and private well water) modifies the effect of hydrology on childhood (aged < 5 years) gastrointestinal illness. We conducted a time series study to assess the relationship between hydrologic and weather conditions with childhood gastrointestinal illness from 1991 to 2010. The Central and Northern Wisconsin study area includes households using all 3 types of drinking water systems. Separate time series models were created for each system and half-year period (winter/spring, summer/fall). More precipitation (summer/fall) systematically increased childhood gastrointestinal illness in municipalities accessing untreated water. The relative risk of contracting gastrointestinal illness was 1.4 in weeks with 3 centimeters of precipitation and 2.4 in very wet weeks with 12 centimeters of precipitation. By contrast, gastrointestinal illness in private well and treated municipal areas was not influenced by hydrologic conditions, although warmer winter temperatures slightly increased incidence. Our study suggests that improved drinking water protection, treatment, and delivery infrastructure may improve public health by specifically identifying municipal water systems lacking water treatment that may transmit waterborne disease.
Changes in Blood Lead Levels Associated with Use of Chloramines in Water Treatment Systems
Miranda, Marie Lynn; Kim, Dohyeong; Hull, Andrew P.; Paul, Christopher J.; Galeano, M. Alicia Overstreet
2007-01-01
Background More municipal water treatment plants are using chloramines as a disinfectant in order to reduce carcinogenic by-products. In some instances, this has coincided with an increase in lead levels in drinking water in those systems. Lead in drinking water can be a significant health risk. Objectives We sought to test the potential effect of switching to chloramines for disinfection in water treatment systems on childhood blood lead levels using data from Wayne County, located in the central Coastal Plain of North Carolina. Methods We constructed a unified geographic information system (GIS) that links blood lead screening data with age of housing, drinking water source, and census data for 7,270 records. The data were analyzed using both exploratory methods and more formal multivariate techniques. Results The analysis indicates that the change to chloramine disinfection may lead to an increase in blood lead levels, the impact of which is progressively mitigated in newer housing. Conclusions Introducing chloramines to reduce carcinogenic by-products may increase exposure to lead in drinking water. Our research provides guidance on adjustments in the local childhood lead poisoning prevention program that should accompany changes in water treatment. As similar research is conducted in other areas, and the underlying environmental chemistry is clarified, water treatment strategies can be optimized across the multiple objectives that municipalities face in providing high quality drinking water to local residents. PMID:17384768
Beer, Karlyn D; Gargano, Julia W; Roberts, Virginia A; Hill, Vincent R; Garrison, Laurel E; Kutty, Preeta K; Hilborn, Elizabeth D; Wade, Timothy J; Fullerton, Kathleen E; Yoder, Jonathan S
2015-08-14
Advances in water management and sanitation have substantially reduced waterborne disease in the United States, although outbreaks continue to occur. Public health agencies in the U.S. states and territories* report information on waterborne disease outbreaks to the CDC Waterborne Disease and Outbreak Surveillance System (http://www.cdc.gov/healthywater/surveillance/index.html). For 2011-2012, 32 drinking water-associated outbreaks were reported, accounting for at least 431 cases of illness, 102 hospitalizations, and 14 deaths. Legionella was responsible for 66% of outbreaks and 26% of illnesses, and viruses and non-Legionella bacteria together accounted for 16% of outbreaks and 53% of illnesses. The two most commonly identified deficiencies† leading to drinking water-associated outbreaks were Legionella in building plumbing§ systems (66%) and untreated groundwater (13%). Continued vigilance by public health, regulatory, and industry professionals to identify and correct deficiencies associated with building plumbing systems and groundwater systems could prevent most reported outbreaks and illnesses associated with drinking water systems.
Grady, S.J.; Casey, G.D.
2001-01-01
Data on volatile organic compounds (VOCs) in drinking water supplied by 2,110 randomly selected community water systems (CWSs) in 12 Northeast and Mid-Atlantic States indicate 64 VOC analytes were detected at least once during 1993-98. Selection of the 2,110 CWSs inventoried for this study targeted 20 percent of the 10,479 active CWSs in the region and represented a random subset of the total distribution by State, source of water, and size of system. The data include 21,635 analyses of drinking water collected for compliance monitoring under the Safe Drinking Water Act; the data mostly represent finished drinking water collected at the pointof- entry to, or at more distal locations within, each CWS?s distribution system following any watertreatment processes. VOC detections were more common in drinking water supplied by large systems (serving more than 3,300 people) that tap surface-water sources or both surface- and groundwater sources than in small systems supplied exclusively by ground-water sources. Trihalomethane (THM) compounds, which are potentially formed during the process of disinfecting drinking water with chlorine, were detected in 45 percent of the randomly selected CWSs. Chloroform was the most frequently detected THM, reported in 39 percent of the CWSs. The gasoline additive methyl tert-butyl ether (MTBE) was the most frequently detected VOC in drinking water after the THMs. MTBE was detected in 8.9 percent of the 1,194 randomly selected CWSs that analyzed samples for MTBE at any reporting level, and it was detected in 7.8 percent of the 1,074 CWSs that provided MTBE data at the 1.0-?g/L (microgram per liter) reporting level. As with other VOCs reported in drinking water, most MTBE concentrations were less than 5.0 ?g/L, and less than 1 percent of CWSs reported MTBE concentrations at or above the 20.0-?g/L lower limit recommended by the U.S. Environmental Protection Agency?s Drinking-Water Advisory. The frequency of MTBE detections in drinking water is significantly related to high- MTBE-use patterns. Detections are five times more likely in areas where MTBE is or has been used in gasoline at greater than 5 percent by volume as part of the oxygenated or reformulated (OXY/RFG) fuels program. Detection frequencies of the individual gasoline compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX)) were mostly less than 3 percent of the randomly selected CWSs, but collectively, BTEX compounds were detected in 8.4 percent of CWSs. BTEX concentrations also were low and just three drinkingwater samples contained BTEX at concentrations exceeding 20 ?g/L. Co-occurrence of MTBE and BTEX was rare, and only 0.8 percent of CWSs reported simultaneous detections of MTBE and BTEX compounds. Low concentrations and cooccurrence of MTBE and BTEX indicate most gasoline contaminants in drinking water probably represent nonpoint sources. Solvents were frequently detected in drinking water in the 12-State area. One or more of 27 individual solvent VOCs were detected at any reporting level in 3,080 drinking-water samples from 304 randomly selected CWSs (14 percent) and in 206 CWSs (9.8 percent) at concentrations at or above 1.0 ?g/L. High co-occurrence among solvents probably reflects common sources and the presence of transformation by-products. Other VOCs were relatively rarely detected in drinking water in the 12-State area. Six percent (127) of the 2,110 randomly selected CWSs reported concentrations of 16 VOCs at or above drinking-water criteria. The 127 CWSs collectively serve 2.6 million people. The occurrence of VOCs in drinking water was significantly associated (p<0.0001) with high population- density urban areas. New Jersey, Massachusetts, and Rhode Island, States with substantial urbanization and high population density, had the highest frequency of VOC detections among the 12 States. More than two-thirds of the randomly selected CWSs in New Jersey reported detecting VOC concentrations in drinking water at or above 1
Safe and Affordable Drinking Water for Developing Countries
NASA Astrophysics Data System (ADS)
Gadgil, Ashok
2008-09-01
Safe drinking water remains inaccessible for about 1.2 billion people in the world, and the hourly toll from biological contamination of drinking water is 200 deaths mostly among children under five years of age. This chapter summarizes the need for safe drinking water, the scale of the global problem, and various methods tried to address it. Then it gives the history and current status of an innovation ("UV Waterworks™") developed to address this major public health challenge. It reviews water disinfection technologies applicable to achieve the desired quality of drinking water in developing countries, and specifically, the limitations overcome by one particular invention: UV Waterworks. It then briefly describes the business model and financing option than is accelerating its implementation for affordable access to safe drinking water to the unserved populations in these countries. Thus this chapter describes not only the innovation in design of a UV water disinfection system, but also innovation in the delivery model for safe drinking water, with potential for long term growth and sustainability.
TENORM: Drinking Water Treatment Residuals
EPA has specific regulations under the Safe Drinking Water Act (SDWA) that limit the amount of radioactivity allowed in community water systems. Learn about methods used to treat these water supplies to remove radioactivity and manage wastes.
SOURCE WATER ASSESSMENT USING GEOGRAPHIC INFORMATION SYSTEMS
The 1996 amendments to Section 1453 of the Safe Drinking Water Act require the states to establish and implement a Source Water Assessment Program (SWAP). Source water is the water taken from rivers, reservoirs, or wells for use as public drinking water. Source water assessment i...
UV DISINFECTION GUIDANCE MANUAL FOR THE ...
Provides technical information on selection, design and operation of UV systems; provides regulatory agencies with guidance and the necessary tools to assess UV systems at the design, start-up, and routine operation phase; provides manufacturers with the testing and performance standards for UV components and systems for treating drinking water. Provide guidance to water systems, regulators and manufacturers on UV disinfection of drinking water.
77 FR 12580 - Public Water System Supervision Program Revision for the State of Colorado
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... (CDPHE), Drinking Water Section, 4300 Cherry Creek Drive South, Denver, CO. FOR FURTHER INFORMATION... accordance with the provisions of section 1413 of the Safe Drinking Water Act (SDWA), 42 U.S.C. 300g-2, and... correspond to the National Primary Drinking Water Regulations (NPDWR) in 40 CFR parts 141 and 142. The EPA...
Massoud, May A; Al-Abady, Abdolmonim; Jurdi, Mey; Nuwayhid, Iman
2010-06-01
Adequate and safe water is important for human health and well-being, economic production, and sustainable development. Failure to ensure the safety of drinking water may expose the community to the risk of outbreaks of waterborne and infectious diseases. Although drinking water is a basic human right, many people do not have access to safe and adequate drinking water or proper sanitation facilities. The authors conducted a study to assess the quantity, cost, continuity, coverage, and quality of drinking water in the village of Zawtar El-Charkieh, Lebanon. Their aim was to identify the challenges of sustainable access to safe drinking water in order to determine the short-term management actions and long-term strategies to improve water quality. Results revealed that contamination of the source, absence of any disinfection method or insufficient dose, poor maintenance operations, and aging of the networks are significant factors contributing to water contamination during the storage and distribution process. Establishing a comprehensive drinking water system that integrates water supply, quality, and management as well as associated educational programs in order to ensure the safety and sustainability of drinking water supplies is essential.
Consequences and Reduction of Elevated Ammonia in Illinois Groundwaters: U.S. EPA Research Efforts
Nitrification in drinking water distribution systems is a concern of many drinking water systems. Although chloramination as a source of nitrification has drawn the most attention, many source waters contain significant levels of ammonia, particularly in Midwestern States such a...
A Comprehensive Investigation of Copper Pitting Corrosion in a Drinking Water Distribution System
Copper pipe pitting is a complicated corrosion process for which exact causes and solutions are uncertain. This paper presents the findings of a comprehensive investigation of a cold water copper pitting corrosion problem in a drinking water distribution system, including a refi...
ARSENIC REMOVAL FROM DRINKING WATER BY IRON REMOVAL PLANTS
This report documents a long term performance study of two iron removal water treatment plants to remove arsenic from drinking water sources. Performance information was collected from one system located in midwest for one full year and at the second system located in the farwest...
The description of microorganisms inhabiting drinking water distribution systems has commonly been performed using techniques that are biased towards easy to culture bacterial populations. As most environmental microorganisms cannot be grown on artificial media, our understanding...
2013-09-06
Despite advances in water management and sanitation, waterborne disease outbreaks continue to occur in the United States. CDC collects data on waterborne disease outbreaks submitted from all states and territories through the Waterborne Disease and Outbreak Surveillance System. During 2009-2010, the most recent years for which finalized data are available, 33 drinking water-associated outbreaks were reported, comprising 1,040 cases of illness, 85 hospitalizations, and nine deaths. Legionella accounted for 58% of outbreaks and 7% of illnesses, and Campylobacter accounted for 12% of outbreaks and 78% of illnesses. The most commonly identified outbreak deficiencies in drinking water-associated outbreaks were Legionella in plumbing systems (57.6%), untreated ground water (24.2%), and distribution system deficiencies (12.1%), suggesting that efforts to identify and correct these deficiencies could prevent many outbreaks and illnesses associated with drinking water. In addition to the drinking water outbreaks, 12 outbreaks associated with other nonrecreational water were reported, comprising 234 cases of illness, 51 hospitalizations, and six deaths. Legionella accounted for 58% of these outbreaks, 42% of illnesses, 96% of hospitalizations, and all deaths. Public health, regulatory, and industry professionals can use this information to target prevention efforts against pathogens, infrastructure problems, and water sources associated with waterborne disease outbreaks.
Schock, Michael R; Hyland, Robert N; Welch, Meghan M
2008-06-15
Previously, contaminants, such as AI, As, and Ra, have been shown to accumulate in drinking-water distribution system solids. Accumulated contaminants could be periodically released back into the water supply causing elevated levels at consumers taps, going undetected by most current regulatory monitoring practices and consequently constituting a hidden risk. The objective of this study was to determine the occurrence of over 40 major scale constituents, regulated metals, and other potential metallic inorganic contaminants in drinking-water distribution system Pb (lead) or Pb-lined service lines. The primary method of analysis was inductively coupled plasma-atomic emission spectroscopy, following complete decomposition of scale material. Contaminants and scale constituents were categorized by their average concentrations, and many metals of potential health concern were found to occur at levels sufficient to result in elevated levels at the consumer's taps if they were to be mobilized. The data indicate distinctly nonconservative behavior for many inorganic contaminants in drinking-water distribution systems. This finding suggests an imminent need for further research into the transport and fate of contaminants throughout drinking-water distribution system pipes, as well as a re-evaluation of monitoring protocols in order to more accurately determine the scope and levels of potential consumer exposure.
Gerrity, Daniel; Arnold, Mayara; Dickenson, Eric; Moser, Duane; Sackett, Joshua D; Wert, Eric C
2018-05-15
Microbial community structure in the ozone-biofiltration systems of two drinking water and two wastewater treatment facilities was characterized using 16S rRNA gene sequencing. Collectively, these datasets enabled comparisons by facility, water type (drinking water, wastewater), pre-oxidation (ozonation, chlorination), media type (anthracite, activated carbon), media depth, and backwash dynamics. Proteobacteria was the most abundant phylum in drinking water filters, whereas Bacteroidetes, Chloroflexi, Firmicutes, and Planctomycetes were differentially abundant in wastewater filters. A positive correlation was observed between media depth and relative abundance of Cyanobacteria in drinking water filters, but there was only a slight increase in one alpha diversity metric with depth in the wastewater filters. Media type had a significant effect on beta but not alpha diversity in drinking water and wastewater filters. Pre-ozonation caused a significant decrease in alpha diversity in the wastewater filters, but the effect on beta diversity was not statistically significant. An evaluation of backwash dynamics resulted in two notable observations: (1) endosymbionts such as Neochlamydia and Legionella increased in relative abundance following backwashing and (2) nitrogen-fixing Bradyrhizobium dominated the microbial community in wastewater filters operated with infrequent backwashing. Bradyrhizobium is known to generate extracellular polymeric substances (EPS), which may adversely impact biofilter performance and effluent water quality. These findings have important implications for public health and the operation and resiliency of biofiltration systems. Copyright © 2018 Elsevier Ltd. All rights reserved.
40 CFR 35.3500 - Purpose, policy, and applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Revolving Fund program under section 1452 of the Safe Drinking Water Act, as amended in 1996. It applies to... health protection objectives of the Safe Drinking Water Act, promote the efficient use of all funds, and... systems. (b) This subpart supplements section 1452 of the Safe Drinking Water Act by codifying statutory...
40 CFR 35.3500 - Purpose, policy, and applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Revolving Fund program under section 1452 of the Safe Drinking Water Act, as amended in 1996. It applies to... health protection objectives of the Safe Drinking Water Act, promote the efficient use of all funds, and... systems. (b) This subpart supplements section 1452 of the Safe Drinking Water Act by codifying statutory...
"Drinking water quality at the consumer's tap is the center piece of U.S. drinking water regulations to protect people's health. Recently promulgated Stage II DBP rules are an example, which requires a system approach in a multi-barrier strategy for compliance and risk managemen...
Effect of sodium hypochlorite on typical biofilms formed in drinking water distribution systems.
Lin, Huirong; Zhu, Xuan; Wang, Yuxin; Yu, Xin
2017-04-01
Human health and biological safety problems resulting from urban drinking water pipe network biofilms pollution have attracted wide concern. Despite the inclusion of residual chlorine in drinking water distribution systems supplies, the bacterium is a recalcitrant human pathogen capable of forming biofilms on pipe walls and causing health risks. Typical drinking water bacterial biofilms and their response to different concentrations of chlorination was monitored. The results showed that the four bacteria all formed single biofilms susceptible to sodium hypochlorite. After 30 min disinfection, biomass and cultivability decreased with increasing concentration of disinfectant but then increased in high disinfectant doses. PMA-qPCR results indicated that it resulted in little cellular damage. Flow cytometry analysis showed that with increasing doses of disinfectant, the numbers of clusters increased and the sizes of clusters decreased. Under high disinfectant treatment, EPS was depleted by disinfectant and about 0.5-1 mg/L of residual chlorine seemed to be appropriate for drinking water treatment. This research provides an insight into the EPS protection to biofilms. Resistance of biofilms against high levels of chlorine has implications for the delivery of drinking water.
Pharmaceuticals and endocrine disrupting compounds in U.S. drinking water.
Benotti, Mark J; Trenholm, Rebecca A; Vanderford, Brett J; Holady, Janie C; Stanford, Benjamin D; Snyder, Shane A
2009-02-01
The drinking water for more than 28 million people was screened for a diverse group of pharmaceuticals, potential endocrine disrupting compounds (EDCs), and other unregulated organic contaminants. Source water, finished drinking water, and distribution system (tap) water from 19 U.S. water utilities was analyzed for 51 compounds between 2006 and 2007. The 11 most frequently detected compounds were atenolol, atrazine, carbamazepine, estrone, gemfibrozil, meprobamate, naproxen, phenytoin, sulfamethoxazole, TCEP, and trimethoprim. Median concentrations of these compounds were less than 10 ng/L, except for sulfamethoxazole in source water (12 ng/L), TCEP in source water (120 ng/L), and atrazine in source, finished, and distribution system water (32, 49, and 49 ng/L). Atrazine was detected in source waters far removed from agricultural application where wastewater was the only known source of organic contaminants. The occurrence of compounds in finished drinking water was controlled by the type of chemical oxidation (ozone or chlorine) used at each plant. At one drinking water treatment plant, summed monthly concentrations of the detected analytes in source and finished water are reported. Atenolol, atrazine, DEET, estrone, meprobamate, and trimethoprim can serve as indicator compounds representing potential contamination from other pharmaceuticals and EDCs and can gauge the efficacy of treatment processes.
Draft genome sequence of two Shingopyxis sp. strains H107 and H115 isolated from a chloraminated drinking water distriburion system simulatorThis dataset is associated with the following publication:Gomez-Alvarez, V., S. Pfaller , and R. Revetta. Draft Genome of Two Sphingopyxis sp. Strains, Dominant Members of the Bacterial Community Associated with a Drinking Water Distribution System Simulator. Genome Announcements. American Society for Microbiology, Washington, DC, USA, 4(2): e00183-16, (2016).
Drinking water for dairy cattle: always a benefit or a microbiological risk?
Van Eenige, M J E M; Counotte, G H M; Noordhuizen, J P T M
2013-02-01
Drinking water can be considered an essential nutrient for dairy cattle. However, because it comes from different sources, its chemical and microbiological quality does not always reach accepted standards. Moreover, water quality is not routinely assessed on dairy farms. The microecology of drinking water sources and distribution systems is rather complex and still not fully understood. Water quality is adversely affected by the formation of biofilms in distribution systems, which form a persistent reservoir for potentially pathogenic bacteria. Saprophytic microorganisms associated with such biofilms interact with organic and inorganic matter in water, with pathogens, and even with each other. In addition, the presence of biofilms in water distribution systems makes cleaning and disinfection difficult and sometimes impossible. This article describes the complex dynamics of microorganisms in water distribution systems. Water quality is diminished primarily as a result of faecal contamination and rarely as a result of putrefaction in water distribution systems. The design of such systems (with/ without anti-backflow valves and pressure) and the materials used (polyethylene enhances biofilm; stainless steel does not) affect the quality of water they provide. The best option is an open, funnel-shaped galvanized drinking trough, possibly with a pressure system, air inlet, and anti-backflow valves. A poor microbiological quality of drinking water may adversely affect feed intake, and herd health and productivity. In turn, public health may be affected because cattle can become a reservoir of microorganisms hazardous to humans, such as some strains of E. coli, Yersinia enterocolitica, and Campylobacter jejuni. A better understanding of the biological processes in water sources and distribution systems and of the viability of microorganisms in these systems may contribute to better advice on herd health and productivity at a farm level. Certain on-farm risk factors for water quality have been identified. A practical approach will facilitate the control and management of these risks, and thereby improve herd health and productivity.
Stanish, Lee F.; Hull, Natalie M.; Robertson, Charles E.; Harris, J. Kirk; Stevens, Mark J.; Spear, John R.; Pace, Norman R.
2016-01-01
The composition and metabolic activities of microbes in drinking water distribution systems can affect water quality and distribution system integrity. In order to understand regional variations in drinking water microbiology in the upper Ohio River watershed, the chemical and microbiological constituents of 17 municipal distribution systems were assessed. While sporadic variations were observed, the microbial diversity was generally dominated by fewer than 10 taxa, and was driven by the amount of disinfectant residual in the water. Overall, Mycobacterium spp. (Actinobacteria), MLE1-12 (phylum Cyanobacteria), Methylobacterium spp., and sphingomonads were the dominant taxa. Shifts in community composition from Alphaproteobacteria and Betaproteobacteria to Firmicutes and Gammaproteobacteria were associated with higher residual chlorine. Alpha- and beta-diversity were higher in systems with higher chlorine loads, which may reflect changes in the ecological processes structuring the communities under different levels of oxidative stress. These results expand the assessment of microbial diversity in municipal distribution systems and demonstrate the value of considering ecological theory to understand the processes controlling microbial makeup. Such understanding may inform the management of municipal drinking water resources. PMID:27362708
Stanish, Lee F; Hull, Natalie M; Robertson, Charles E; Harris, J Kirk; Stevens, Mark J; Spear, John R; Pace, Norman R
2016-01-01
The composition and metabolic activities of microbes in drinking water distribution systems can affect water quality and distribution system integrity. In order to understand regional variations in drinking water microbiology in the upper Ohio River watershed, the chemical and microbiological constituents of 17 municipal distribution systems were assessed. While sporadic variations were observed, the microbial diversity was generally dominated by fewer than 10 taxa, and was driven by the amount of disinfectant residual in the water. Overall, Mycobacterium spp. (Actinobacteria), MLE1-12 (phylum Cyanobacteria), Methylobacterium spp., and sphingomonads were the dominant taxa. Shifts in community composition from Alphaproteobacteria and Betaproteobacteria to Firmicutes and Gammaproteobacteria were associated with higher residual chlorine. Alpha- and beta-diversity were higher in systems with higher chlorine loads, which may reflect changes in the ecological processes structuring the communities under different levels of oxidative stress. These results expand the assessment of microbial diversity in municipal distribution systems and demonstrate the value of considering ecological theory to understand the processes controlling microbial makeup. Such understanding may inform the management of municipal drinking water resources.
Burden of Cancer from Chemicals in North Carolina Drinking Water
NASA Astrophysics Data System (ADS)
DeFelice, N.
2013-12-01
Monitoring programs required by the U.S. Safe Drinking Water Act (SDWA) currently do not consider potential differences in chemical exposure patterns and human health risks. Rather, U.S. agencies establish monitoring requirements based on the type of water system and the number of people the system serves; within categories of systems, all potentially carcinogenic chemicals must be monitored with equal frequency, regardless of the potential level of risk these chemicals pose. To inform future policies concerning contaminant monitoring under the SDWA, we examined the potential health threats in North Carolina from the 34 carcinogenic chemicals covered under the SDWA. We analyzed reported contaminant concentration data for all community water systems (CWSs) for the years 1998-2011. We employed an attributable fraction approach that uses probabilistic inputs to evaluate the percent of cancer cases that may be attributable to chemical exposure in drinking water. We found that cancer risks are dominated by 3 of the 34 chemicals and chemical classes (total trihalomethanes (TTHMs), arsenic and gross alpha particles); all other chemicals contribute to less than one cancer case per year in the state. We showed that around 840 cases of cancer annually (2% of annual cancer cases) are attributable to contaminated drinking water. The majority cases are due to TTHMs, arsenic and gross alpha particles, which contributed 810 (95% CI 560-1,280), 14 (95% CI 3 -32), and 13 (95% CI 2-48) cases, respectively. Sixty-seven counties had annual cancer rates higher than 1 in 10,000 attributable to community water systems. Annual cancer rate attributable to chemicals found in drinking water that are regulated under the safe drinking water act.
Dangel, Chrissy; Allgeier, Steven C; Gibbons, Darcy; Haas, Adam; Simon, Katie
2012-03-01
Effective communication and coordination are critical when investigating a possible drinking water contamination incident. A contamination warning system is designed to detect water contamination by initiating a coordinated, effective response to mitigate significant public health and economic consequences. This article describes historical communication barriers during water contamination incidents and discusses how these barriers were overcome through the public health surveillance component of the Cincinnati Drinking Water Contamination Warning System, referred to as the "Cincinnati Pilot." By enhancing partnerships in the public health surveillance component of the Cincinnati Pilot, information silos that existed in each organization were replaced with interagency information depots that facilitated effective decision making.
[On the rating of Helicobacter pylori in drinking water].
Fedichkina, T P; Solenova, L G; Zykova, I E
2014-01-01
There are considered the issues related to the possibility to rate of Helicobacter pylori (H. pylori) content in drinking water. There is described the mechanism of of biofilm formation. The description refers to the biofilm formation mechanism in water supply systems and the existence of H. pylori in those systems. The objective premises of the definition of H. pylori as a potential limiting factor for assessing the quality of drinking water have been validated as follows: H. pylori is an etiologic factor associated to the development of chronic antral gastritis, gastric ulcer and duodenal ulcer, and gastric cancer either, in the Russian population the rate of infection with H. pylori falls within range of 56 - 90%, water supply pathway now can be considered as a source of infection of the population with H. pylori, the existence of WHO regulatory documents considering H. pylori as a candidate for standardization of the quality of the drinking water quite common occurrence of biocorrosion, the reduction of sanitary water network reliability, that creates the possibility of concentrating H. pylori in some areas of the water system and its delivery to the consumer of drinking water, and causes the necessity of the prevention of H. pylori-associated gastric pathology of the population. A comprehensive and harmonized approach to H. pylori is required to consider it as a candidate to its rating in drinking water. Bearing in mind the large economic losses due to, on the one hand, the prevalence of disease caused by H. pylori, and, on the other hand, the biocorrosion of water supply system, the problem is both relevant in terms of communal hygiene and economy.
Beyond Flint: National Trends in Drinking Water Quality Violations
NASA Astrophysics Data System (ADS)
Allaire, M.; Wu, H.; Lall, U.
2016-12-01
Ensuring safe water supply for communities across the U.S. represents an emerging challenge. Aging infrastructure, impaired source water, and strained community finances may increase vulnerability of water systems to quality violations. In the aftermath of Flint, there is a great need to assess the current state of U.S. drinking water quality. How widespread are violations? What are the spatial and temporal patterns in water quality? Which types of communities and systems are most vulnerable? This is the first national assessment of trends in drinking water quality violations across several decades. In 2015, 9% of community water systems violated health-related water quality standards. These non-compliant systems served nearly 23 million people. Thus, the challenge of providing safe drinking water extends beyond Flint and represents a nationwide concern. We use a panel dataset that includes every community water system in the United States from 1981 to 2010 to identify factors that lead to regulatory noncompliance. This study focuses on health-related violations of the Safe Drinking Water Act. Lasso regression informed selection of appropriate covariates, while logistic regressions modeled the probability of noncompliance. We find that compliance is positively associated with private ownership, purchased water supply, and greater household income. Yet, greater concentration of utility ownership and violations in prior years are associated with a higher likelihood of violation. The results suggest that purchased water contracts, which are growing among small utilities, could serve as a way to improve regulatory compliance in the future. However, persistence of violations and ownership concentration deserve attention from policymakers. Already, the EPA has begun to prioritize enforcement of persistent violators. Overall, as the revitalization of U.S. water infrastructure becomes a growing priority area, results of this study are intended to inform investment and policy.
Free chlorine is used as the primary disinfectant in most drinking water distribution systems(DWDS). However, chlorine disinfection promotes the formation of disinfectant by-products (DBPs)and as a result, many US water treatment facilities use chloramination to ensure regulatory...
Previous work has shown that contaminants, such as Al, As and Ra, can accumulate in drinking water distribution system solids. The release of accumulated contaminants back into the water supply could result in elevated levels at consumers’ taps, and current monitoring practices d...
Previous work has shown that contaminants such as Al, As and Ra, can accumulate in drinking water distribution system solids. The release of accumulated contaminants back into the water supply could conceivably result in elevated levels at consumers’ taps. The current regulatory...
Bacterial populations were examined in a simulated chloraminated drinking water distribution system (i.e. loop). The loop (BW-AB-I) received chlorinated municipal water (BW-C) amended with ammonia (2mg/L monochloramine). After six years of continuous operation, the operational ...
Lehtola, Markku J; Miettinen, Ilkka T; Hirvonen, Arja; Vartiainen, Terttu; Martikainen, Pertti J
2007-12-01
The numbers of bacteria generally increase in distributed water. Often household pipelines or water fittings (e.g., taps) represent the most critical location for microbial growth in water distribution systems. According to the European Union drinking water directive, there should not be abnormal changes in the colony counts in water. We used a pilot distribution system to study the effects of water stagnation on drinking water microbial quality, concentration of copper and formation of biofilms with two commonly used pipeline materials in households; copper and plastic (polyethylene). Water stagnation for more than 4h significantly increased both the copper concentration and the number of bacteria in water. Heterotrophic plate counts were six times higher in PE pipes and ten times higher in copper pipes after 16 h of stagnation than after only 40 min stagnation. The increase in the heterotrophic plate counts was linear with time in both copper and plastic pipelines. In the distribution system, bacteria originated mainly from biofilms, because in laboratory tests with water, there was only minor growth of bacteria after 16 h stagnation. Our study indicates that water stagnation in the distribution system clearly affects microbial numbers and the concentration of copper in water, and should be considered when planning the sampling strategy for drinking water quality control in distribution systems.
Stang, Shannon; Wang, Haiying; Gardner, Kevin H; Mo, Weiwei
2018-07-15
As drinking water supply systems plan for sustainable management practices, impacts from future water quality and climate changes are a major concern. This study aims to understand the intraannual changes of energy consumption for water treatment, investigate the relative importance of water quality and climate indicators on energy consumption for water treatment, and predict the effects of climate change on the embodied energy of treated, potable water at two municipal drinking water systems located in the northeast and southeast US. To achieve this goal, a life cycle assessment was first performed to quantify the monthly energy consumption in the two drinking water systems. Regression and relative importance analyses were then performed between climate indicators, raw water quality indicators, and chemical and energy usages in the treatment processes to determine their correlations. These relationships were then used to project changes in embodied energy associated with the plants' processes, and the results were compared between the two regions. The projections of the southeastern US water plant were for an increase in energy demand resulted from an increase of treatment chemical usages. The northeastern US plant was projected to decrease its energy demand due to a reduced demand for heating the plant's infrastructure. The findings indicate that geographic location and treatment process may determine the way climate change affects drinking water systems. Copyright © 2018 Elsevier Ltd. All rights reserved.
Codony, Francesc; Pérez, Leonardo Martín; Adrados, Bárbara; Agustí, Gemma; Fittipaldi, Mariana; Morató, Jordi
2012-01-01
Culture-based methods for fecal indicator microorganisms are the standard protocol to assess potential health risk from drinking water systems. However, these traditional fecal indicators are inappropriate surrogates for disinfection-resistant fecal pathogens and the indigenous pathogens that grow in drinking water systems. There is now a range of molecular-based methods, such as quantitative PCR, which allow detection of a variety of pathogens and alternative indicators. Hence, in addition to targeting total Escherichia coli (i.e., dead and alive) for the detection of fecal pollution, various amoebae may be suitable to indicate the potential presence of pathogenic amoeba-resisting microorganisms, such as Legionellae. Therefore, monitoring amoeba levels by quantitative PCR could be a useful tool for directly and indirectly evaluating health risk and could also be a complementary approach to current microbial quality control strategies for drinking water systems.
Hentschel, W; Voigt, K; Heudorf, U
2006-08-01
The monitoring of drinking water based on the drinking water regulation is one of the central tasks of public health authorities in Germany. With the coming into force of the new drinking water regulation in the year 2003 also water supply plants "from which water is made available for the public, in particular in schools, kindergartens, hospitals, restaurants and other communal facilities" must be supervised for the first time (TrinkwV section sign 18). Thus, for Frankfurt/Main the number of the facilities/objects which are to be supervised rose from approx. 300 to approx. 4,700. Since appropriate expansion of personnel was not possible, innovative solutions were in demand for implementation of these tasks. These are introduced here.
Drinking Water Supply without Use of a Disinfectant
NASA Astrophysics Data System (ADS)
Rajnochova, Marketa; Tuhovcak, Ladislav; Rucka, Jan
2018-02-01
The paper focuses on the issue of drinking water supply without use of any disinfectants. Before the public water supply network operator begins to consider switching to operation without use of chemical disinfection, initial assessment should be made, whether or not the water supply system in question is suitable for this type of operation. The assessment is performed by applying the decision algorithm. The initial assessment is followed by another decision algorithm which serves for managing and controlling the process of switching to drinking water supply without use of a disinfectant. The paper also summarizes previous experience and knowledge of this way operated public water supply systems in the Czech Republic.
Cappello, Michael Anthony; Ferraro, Aimee; Mendelsohn, Aaron B; Prehn, Angela Witt
2013-11-01
In the study discussed in this article, 27 private drinking water wells located in a rural Colorado mountain community were sampled for radon contamination and compared against (a) the U.S. Environmental Protection Agency's (U.S. EPA's) proposed maximum contaminant level (MCL), (b) the U.S. EPA proposed alternate maximum contaminate level (AMCL), and (c) the average radon level measured in the local municipal drinking water system. The data from the authors' study found that 100% of the wells within the study population had radon levels in excess of the U.S. EPA MCL, 37% were in excess of the U.S. EPA AMCL, and 100% of wells had radon levels greater than that found in the local municipal drinking water system. Radon contamination in one well was found to be 715 times greater than the U.S. EPA MCL, 54 times greater than the U.S. EPA AMLC, and 36,983 times greater than that found in the local municipal drinking water system. According to the research data and the reviewed literature, the results indicate that this population has a unique and elevated contamination profile and suggest that radon-contaminated drinking water from private wells can present a significant public health concern.
Pennsylvania Village to Get Safe, Reliable Water Supply
A Pennsylvania village whose unfiltered, contaminated water source made it the top violator of federal and state drinking water laws will be connected to a public water system in 2015 with $2.2 million from EPA’s Drinking Water State Revolving Fund
Chicago Lead in Drinking Water Study
EPA Region 5 and the Chicago Department of Water Management conducted a study on field sampling protocols for lead in drinking water. The purpose of the study was to evaluate the method used by public water systems to monitor lead levels.
40 CFR 141.806 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 141.806 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.806 Reporting... and routine disinfection and flushing frequency must be included in the aircraft water system...
40 CFR 141.500 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 141.500 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving... subpart constitute national primary drinking water regulations. These regulations establish requirements...
40 CFR 141.170 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 141.170 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving... constitute national primary drinking water regulations. These regulations establish requirements for...
Chen, Chien-Jen
2014-01-01
There are two endemic areas of long-term exposure to arsenic from drinking water in Taiwan. Residents in the southwestern and northeastern endemic areas started using high-arsenic artesian well water in the early 1910s and late 1940s, respectively. Public water supply system using surface water was implemented in southwestern and northeastern endemic areas in the 1970s and 1990s, respectively. Systemic health hazards of long-term exposure to arsenic in drinking water have been intensively investigated since the 1960s, especially after 1985 in Taiwan. Several diseases have been well documented to be associated with chronic arsenic poisoning from drinking water showing a dose-response relation. They include characteristic skin lesions like hyperpigmentation or depigmentation, hyperkeratosis in palms and soles, and Bowen disease, peripheral vascular disease (specifically blackfoot disease), ischemic heart disease, cerebral infarction, microvascular diseases, abnormal peripheral microcirculation, carotid atherosclerosis, QT prolongation and increased dispersion in electrocardiography, hypertension, goiter, diabetes mellitus, cataract (specifically posterior subcapsular lens opacity), pterygium, slow neural conduction, retarded neurobehavioral development, erectile dysfunction, and cancers of the skin, lung, urinary bladder, kidney, and liver. The method of choice to mitigate arsenic poisoning through drinking water is to use safe drinking water from uncontaminated sources.
Methyl tert-butyl ether (MTBE) in finished drinking water in Germany.
Kolb, Axel; Püttmann, Wilhelm
2006-03-01
In the present study 83 finished drinking water samples from 50 cities in Germany were analyzed for methyl tert-butyl ether (MTBE) content with a detection limit of 10 ng/L. The detection frequency was 46% and the concentrations ranged between 17 and 712 ng/L. Highest concentrations were found in the community water systems (CWSs) of Leuna and Spergau in Saxony-Anhalt. These CWSs are supplied with water possibly affected by MTBE contaminated groundwater. MTBE was detected at concentrations lower than 100 ng/L in drinking water supplied by CWSs using bank filtered water from Rhine and Main Rivers. The results from Leuna and Spergau show that large groundwater contaminations in the vicinity of CWSs pose the highest risk for MTBE contamination in drinking water. CWSs using bank filtered water from Rhine and Main Rivers are susceptible to low MTBE contaminations in finished drinking water. All measured MTBE concentrations were below proposed limit values for drinking water.
Extreme Precipitation, Public Health Emergencies, and Safe Drinking Water in the USA.
Exum, Natalie G; Betanzo, Elin; Schwab, Kellogg J; Chen, Thomas Y J; Guikema, Seth; Harvey, David E
2018-06-01
This review examines the effectiveness of drinking water regulations to inform public health during extreme precipitation events. This paper estimates the vulnerability of specific populations to flooding in their public water system, reviews the literature linking precipitation to waterborne outbreaks, examines the role that Safe Drinking Water Act and Public Notification (PN) Rule have in public health emergencies, and reviews the effectiveness of the PN Rule during the 2017 Hurricane Maria in Puerto Rico. Public water systems in large metropolitan areas have substantial portions of their customer base at risk for a waterborne outbreak during a flooding event. The PN Rule are ambiguous for who is responsible for declaring a "waterborne emergency" following a natural disaster like Hurricane Maria. Revisions to the current PN Rule that mandate public notification and water quality sampling during extreme precipitation events are necessary to ensure the public is aware of their drinking water quality following these events.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-05
... Regional Partners and Other Interested Parties for Implementation of the Aircraft Drinking Water Rule... Agency (EPA) will hold a two-day training session on the regulatory requirements of the Aircraft Drinking... water systems'' under the Safe Drinking Water Act (SDWA) must meet the first set of requirements of the...
Implications of biofilm-associated waterborne Cryptosporidium oocysts for the water industry.
Angles, Mark L; Chandy, Joseph P; Cox, Peter T; Fisher, Ian H; Warnecke, Malcolm R
2007-08-01
Waterborne Cryptosporidium has been responsible for drinking water-associated disease outbreaks in a number of developed countries. As a result of the resistance of Cryptosporidium to chlorine, which is typically applied as a final barrier to protect the quality of distributed drinking water, current management practices are focused on source-water management and water treatment as ways of preventing Cryptosporidium from entering drinking-water supplies. In the event that treatment barriers fail, surprisingly little is known of the fate of oocysts once they enter a distribution system. To assess properly the risks of waterborne Cryptosporidium, a more thorough understanding of the fate of oocysts in water distribution systems, with emphasis on Cryptosporidium-biofilm interactions, is required.
Communicating Research to Small Drinking Water Systems: Dissemination by Researchers
This talk discusses the challenges of disseminating research relevant to small systems. The presentation discusses efforts by the U.S. EPA’s Office of Research and Development to effectively communicating drinking water information. In particular, communication approaches ...
Overview of EPA Research on Drinking Water Distribution System Nitrification
Results from USEPA research investigating drinking water distribution system nitrification will be presented. The two research areas include: (1) monochloramine disinfection kinetics of Nitrosomonas europaea using Propidium Monoazide Quantitative Real-time PCR (PMA-qPCR) and (2...
EFFECT OF BACTERIAL SULFATE REDUCTION ON IRON-CORROSION SCALES
Iron-sulfur geochemistry is important in many natural and engineered environments including drinking water systems. In the anaerobic environment beneath scales of corroding iron drinking water distribution system pipes, sulfate reducing bacteria (SRB) produce sulfide from natura...
Helmi, K; Menard-Szczebara, F; Lénès, D; Jacob, P; Jossent, J; Barbot, C; Delabre, K; Arnal, C
2010-01-01
Biofilms colonizing pipe surfaces of drinking water distribution systems could provide habitat and shelter for pathogenic viruses present in the water phase. This study aims (i) to develop a method to detect viral particles present in a drinking water biofilm and (ii) to study viral interactions with drinking water biofilms. A pilot scale system was used to develop drinking water biofilms on 3 materials (7 cm(2) discs): PVC, cast iron and cement. Biofilms were inoculated with viral model including MS2, PhiX174 or adenovirus. Five techniques were tested to recover virus from biofilms. The most efficient uses beef extract and glycine at pH = 9. After sonication and centrifugation, the pH of the supernatant is neutralized prior to viral analysis. The calculated recovery rates varied from 29.3 to 74.6% depending on the virus (MS2 or PhiX174) and the material. Applying this protocol, the interactions of virus models (MS2 and adenovirus) with drinking water biofilms were compared. Our results show that adsorption of viruses to biofilms depends on their isoelectric points, the disc material and the hydrodynamic conditions. Applying hydrodynamic conditions similar to those existing in drinking water networks resulted in a viral adsorption corresponding to less than 1% of the initial viral load.
Inequities in access to and use of drinking water services in Latin America and the Caribbean.
Soares, Luiz Carlos Rangel; Griesinger, Marilena O; Dachs, J Norberto W; Bittner, Marta A; Tavares, Sonia
2002-01-01
To identify and evaluate inequities in access to drinking water services as reflected in household per capita expenditure on water, and to determine what proportion of household expenditures is spent on water in 11 countries of Latin America and the Caribbean. Using data from multi-purpose household surveys (such as the Living Standards Measurement Survey Study) conducted in 11 countries from 1995 to 1999, the availability of drinking water as well as total and per capita household expenditures on drinking water were analyzed in light of socioeconomic parameters, such as urban vs. rural setting, household income, type and regularity of water supply service, time spent obtaining water in homes not served by running water, and type of water-purifying treatment, if any. Access to drinking water as well as total and per capita household expenditures on drinking water show an association with household income, economic conditions of the household, and location. The access of the rural population to drinking water services is much more restricted than that of the urban population for groups having similar income. The proportion of families having a household water supply system is comparable in the higher-income rural population and the lower-income urban population. Families without a household water supply system spend a considerable amount of time getting water. For poorer families, this implies additional costs. Low-income families that lack a household water supply spend as much money on water as do families with better income. Access to household water disinfection methods is very limited among poor families due to its relatively high cost, which results in poorer drinking water quality in the lower-income population. Multi-purpose household surveys conducted from the consumer's point of view are important tools for research on equity and health, especially when studying unequal access to, use of, and expenditures on drinking water. It is recommended that countries improve their portion of the surveys that deals with water and sanitation in order to facilitate national health assessments and the establishment of more equitable subsidy programs.
Gertsch, Jana C; Noblitt, Scott D; Cropek, Donald M; Henry, Charles S
2010-05-01
A microchip capillary electrophoresis (MCE) system has been developed for the determination of perchlorate in drinking water. The United States Environmental Protection Agency (USEPA) recently proposed a health advisory limit for perchlorate in drinking water of 15 parts per billion (ppb), a level requiring large, sophisticated instrumentation, such as ion chromatography coupled with mass spectrometry (IC-MS), for detection. An inexpensive, portable system is desired for routine online monitoring applications of perchlorate in drinking water. Here, we present an MCE method using contact conductivity detection for perchlorate determination. The method has several advantages, including reduced analysis times relative to IC, inherent portability, high selectivity, and minimal sample pretreatment. Resolution of perchlorate from more abundant ions was achieved using zwitterionic, sulfobetaine surfactants, N-hexadecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate (HDAPS) and N-tetradecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate (TDAPS). The system performance and the optimization of the separation chemistry, including the use of these surfactants to resolve perchlorate from other anions, are discussed in this work. The system is capable of detection limits of 3.4 +/- 1.8 ppb (n = 6) in standards and 5.6 +/- 1.7 ppb (n = 6) in drinking water.
Onsite defluoridation system for drinking water treatment using calcium carbonate.
Wong, Elaine Y; Stenstrom, Michael K
2018-06-15
Fluoride in drinking water has several effects on teeth and bones. At concentrations of 1-1.5 mg/L, fluoride can strengthen enamel, improving dental health, but at concentrations above 1.5 to 4 mg/L can cause dental fluorosis. At concentrations of 4-10 mg/L, skeletal fluorosis can occur. There are many areas of the world that have excessive fluoride in drinking water, such as China, India, Sri Lanka, and the Rift Valley countries in Africa. Treatment solutions are needed, especially in poor areas where drinking water treatment plants are not available. On-site or individual treatment alternatives can be attractive if constructed from common materials and if simple enough to be constructed and maintained by users. Advanced on-site methods, such as under sink reserve osmosis units, can remove fluoride but are too expensive for developing areas. This paper investigates calcium carbonate as a cost effective sorbent for an onsite defluoridation drinking water system. Batch and column experiments were performed to characterize F - removal properties. Fluoride sorption was described by a Freundlich isotherm model, and it was found that the equilibrium time was approximately 3 h. Calcium carbonate was found to have comparable F - removal abilities as the commercial ion exchange resins and possessed higher removal effectiveness compared to calcium containing eggshells and seashells. It was also found that the anion Cl- did not compete with F - at typical drinking water concentrations, having little impact on the effectiveness of the treatment system. A fluoride removal system is proposed that can be used at home and can be maintained by users. Through this work, we can be a step closer to bringing safe drinking water to those that do not have access to it. Copyright © 2017 Elsevier Ltd. All rights reserved.
Su, Hao-Chang; Liu, You-Sheng; Pan, Chang-Gui; Chen, Jun; He, Liang-Ying; Ying, Guang-Guo
2018-03-01
As emerging contaminants, antibiotic resistance genes (ARGs) have become a public concern. This study aimed to investigate the occurrence and diversity of ARGs, and variation in the composition of bacterial communities in source water, drinking water treatment plants, and tap water in the Pearl River Delta region, South China. Various ARGs were present in the different types of water. Among the 27 target ARGs, floR and sul1 dominated in source water from three large rivers in the region. Pearson correlation analysis suggested that sul1, sul2, floR, and cmlA could be potential indicators for ARGs in water samples. The total abundance of the detected ARGs in tap water was much lower than that in source water. Sand filtration and sedimentation in drinking water treatment plants could effectively remove ARGs; in contrast, granular activated carbon filtration increased the abundance of ARGs. It was found that Pseudomonas may be involved in the proliferation and dissemination of ARGs in the studied drinking water treatment system. Bacteria and ARGs were still present in tap water after treatment, though they were significantly reduced. More research is needed to optimize the water treatment process for ARG removal. Copyright © 2017 Elsevier B.V. All rights reserved.
Natural disasters can be devastating to local water supplies affecting millions of people. Disaster recovery plans and water industry collaboration during emergencies protect consumers from contaminated drinking water supplies and help facilitate the repair of public water system...
The drinking water disparities framework: on the origins and persistence of inequities in exposure.
Balazs, Carolina L; Ray, Isha
2014-04-01
With this article, we develop the Drinking Water Disparities Framework to explain environmental injustice in the context of drinking water in the United States. The framework builds on the social epidemiology and environmental justice literatures, and is populated with 5 years of field data (2005-2010) from California's San Joaquin Valley. We trace the mechanisms through which natural, built, and sociopolitical factors work through state, county, community, and household actors to constrain access to safe water and to financial resources for communities. These constraints and regulatory failures produce social disparities in exposure to drinking water contaminants. Water system and household coping capacities lead, at best, to partial protection against exposure. This composite burden explains the origins and persistence of social disparities in exposure to drinking water contaminants.
Lambertini, Elisabetta; Borchardt, Mark A; Kieke, Burney A; Spencer, Susan K; Loge, Frank J
2012-09-04
Acute gastrointestinal illness (AGI) resulting from pathogens directly entering the piping of drinking water distribution systems is insufficiently understood. Here, we estimate AGI incidence from virus intrusions into the distribution systems of 14 nondisinfecting, groundwater-source, community water systems. Water samples for virus quantification were collected monthly at wells and households during four 12-week periods in 2006-2007. Ultraviolet (UV) disinfection was installed on the communities' wellheads during one study year; UV was absent the other year. UV was intended to eliminate virus contributions from the wells and without residual disinfectant present in these systems, any increase in virus concentration downstream at household taps represented virus contributions from the distribution system (Approach 1). During no-UV periods, distribution system viruses were estimated by the difference between well water and household tap virus concentrations (Approach 2). For both approaches, a Monte Carlo risk assessment framework was used to estimate AGI risk from distribution systems using study-specific exposure-response relationships. Depending on the exposure-response relationship selected, AGI risk from the distribution systems was 0.0180-0.0661 and 0.001-0.1047 episodes/person-year estimated by Approaches 1 and 2, respectively. These values represented 0.1-4.9% of AGI risk from all exposure routes, and 1.6-67.8% of risk related to drinking water exposure. Virus intrusions into nondisinfected drinking water distribution systems can contribute to sporadic AGI.
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
Code of Federal Regulations, 2010 CFR
2010-07-01
... SUPPLIES OF DRINKING WATER § 214.8 Exclusions. The authority does not require correcting the contamination, or repair of water systems so that clean drinking water supplies become available again. Reestablishing community water supplies remains the responsibility of local government and other Federal programs...
40 CFR 141.808 - Audits and inspections.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...
40 CFR 141.808 - Audits and inspections.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...
40 CFR 141.808 - Audits and inspections.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...
40 CFR 141.808 - Audits and inspections.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., disinfection and flushing, and general maintenance and self-inspections of aircraft water system. (b) Air... Section 141.808 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.808 Audits and...
Daley, Kiley; Truelstrup Hansen, Lisbeth; Jamieson, Rob C; Hayward, Jenny L; Piorkowski, Greg S; Krkosek, Wendy; Gagnon, Graham A; Castleden, Heather; MacNeil, Kristen; Poltarowicz, Joanna; Corriveau, Emmalina; Jackson, Amy; Lywood, Justine; Huang, Yannan
2017-06-13
Drinking water in the vast Arctic Canadian territory of Nunavut is sourced from surface water lakes or rivers and transferred to man-made or natural reservoirs. The raw water is at a minimum treated by chlorination and distributed to customers either by trucks delivering to a water storage tank inside buildings or through a piped distribution system. The objective of this study was to characterize the chemical and microbial drinking water quality from source to tap in three hamlets (Coral Harbour, Pond Inlet and Pangnirtung-each has a population of <2000) on trucked service, and in Iqaluit (population ~6700), which uses a combination of trucked and piped water conveyance. Generally, the source and drinking water was of satisfactory microbial quality, containing Escherichia coli levels of <1 MPN/100 mL with a few exceptions, and selected pathogenic bacteria and parasites were below detection limits using quantitative polymerase chain reaction (qPCR) methods. Tap water in households receiving trucked water contained less than the recommended 0.2 mg/L of free chlorine, while piped drinking water in Iqaluit complied with Health Canada guidelines for residual chlorine (i.e. >0.2 mg/L free chlorine). Some buildings in the four communities contained manganese (Mn), copper (Cu), iron (Fe) and/or lead (Pb) concentrations above Health Canada guideline values for the aesthetic (Mn, Cu and Fe) and health (Pb) objectives. Corrosion of components of the drinking water distribution system (household storage tanks, premise plumbing) could be contributing to Pb, Cu and Fe levels, as the source water in three of the four communities had low alkalinity. The results point to the need for robust disinfection, which may include secondary disinfection or point-of-use disinfection, to prevent microbial risks in drinking water tanks in buildings and ultimately at the tap.
Ground-water flow and quality in Wisconsin's shallow aquifer system
Kammerer, P.A.
1995-01-01
In terms of chemical quality, the water is suitable for potable supply and most other uses, but objectionable hardness in large areas and concen- trations of iron and manganese that exceed State drinking-water standards cause aesthetic problems that may require treatment of the water for some uses. Concentrations of major dissolved constitu- ents (calcium, magnesium, and bicarbonate), hard- ness, alkalinity, and dissolved solids are highest where the bedrock component of the aquifer is dolo- mite and lowest where the shallow aquifer is almost entirely sand and gravel. Concentrations of other minor constituents (sodium, potassium, sulfate, chloride, and fluoride) are less closely related to common minerals that compose the aquifer system. Sulfate and fluoride concentrations exceed State drinking-water standards locally. Extreme variability in concentrations of iron and manganese are common locally. Iron and manganese concentra- tions exceed State drinking-water standards in water from one-third and one-quarter of the wells, respectively. Likely causes of nitrate-nitrogen con- centrations that exceed State drinking-water stan- dards include local contamination from plant fertilizers, animal wastes, waste water disposed of on land, and septic systems. Water quality in the shallow aquifer system has been affected by saline water from underlying aquifers, primarily along the eastern and western boundaries of the State where the thickness of Paleozoic rocks is greatest.
Rural drinking water issues in India’s drought-prone area: a case of Maharashtra state
NASA Astrophysics Data System (ADS)
Udmale, Parmeshwar; Ichikawa, Yutaka; Nakamura, Takashi; Shaowei, Ning; Ishidaira, Hiroshi; Kazama, Futaba
2016-07-01
Obtaining sufficient drinking water with acceptable quality under circumstances of lack, such as droughts, is a challenge in drought-prone areas of India. This study examined rural drinking water availability issues during a recent drought (2012) through 22 focus group discussions (FGDs) in a drought-prone catchment of India. Also, a small chemical water quality study was undertaken to evaluate the suitability of water for drinking purpose based on Bureau of Indian Standards (BIS). The drought that began in 2011 and further deteriorated water supplies in 2012 caused a rapid decline in reservoir storages and groundwater levels that led, in turn, to the failure of the public water supply systems in the Upper Bhima Catchment. Dried up and low-yield dug wells and borewells, tanker water deliveries from remote sources, untimely water deliveries, and degraded water quality were the major problems identified in the FGDs. In addition to severe drinking water scarcity during drought, the quality of the drinking water was found to be a major problem, and it apparently was neglected by local governments and users. Severe contamination of the drinking water with nitrate-nitrogen, ammonium-nitrogen, and chlorides was found in the analyzed drinking water samples. Hence, in addition to the water scarcity, the results of this study point to an immediate need to investigate the problem of contaminated drinking water sources while designing relief measures for drought-prone areas of India.
Uejio, Christopher K.; Yale, Steven H.; Malecki, Kristen; Borchardt, Mark A.; Anderson, Henry A.; Patz, Jonathan A.
2014-01-01
Objectives. This study investigated if the type of drinking water source (treated municipal, untreated municipal, and private well water) modifies the effect of hydrology on childhood (aged < 5 years) gastrointestinal illness. Methods. We conducted a time series study to assess the relationship between hydrologic and weather conditions with childhood gastrointestinal illness from 1991 to 2010. The Central and Northern Wisconsin study area includes households using all 3 types of drinking water systems. Separate time series models were created for each system and half-year period (winter/spring, summer/fall). Results. More precipitation (summer/fall) systematically increased childhood gastrointestinal illness in municipalities accessing untreated water. The relative risk of contracting gastrointestinal illness was 1.4 in weeks with 3 centimeters of precipitation and 2.4 in very wet weeks with 12 centimeters of precipitation. By contrast, gastrointestinal illness in private well and treated municipal areas was not influenced by hydrologic conditions, although warmer winter temperatures slightly increased incidence. Conclusions. Our study suggests that improved drinking water protection, treatment, and delivery infrastructure may improve public health by specifically identifying municipal water systems lacking water treatment that may transmit waterborne disease. PMID:24524509
Water Supplies: Microbiological Analysis
Producing high-quality drinking water that is free of harmful microorganisms and maintaining its purity through distribution systems are essential for public health. Drinking water quality standards and guidelines for microbial contaminants vary within and among countries but typ...
Drinking Water Cyanotoxin Risk Communication Toolbox
The drinking water cyanotoxin risk communication toolbox is a ready-to-use, “one-stop-shop” to support public water systems, states, and local governments in developing, as they deem appropriate, their own risk communication materials.
Report: Progress Report on Drinking Water Protection Efforts
Report #2005-P-00021, August 22, 2005. EPA and the States in this sample are making progress at helping water systems better reach Congress’ goal of protecting drinking water from its source to the consumer.
Data Tables - Environments and Contaminants - Drinking Water Contaminants
This document contains a table of the estimated percentage of children ages 0 to 17 years served by community water systems that did not meet all applicable health-based drinking water standards, 1993-2009.
Heavy metals in drinking water: Occurrences, implications, and future needs in developing countries.
Chowdhury, Shakhawat; Mazumder, M A Jafar; Al-Attas, Omar; Husain, Tahir
2016-11-01
Heavy metals in drinking water pose a threat to human health. Populations are exposed to heavy metals primarily through water consumption, but few heavy metals can bioaccumulate in the human body (e.g., in lipids and the gastrointestinal system) and may induce cancer and other risks. To date, few thousand publications have reported various aspects of heavy metals in drinking water, including the types and quantities of metals in drinking water, their sources, factors affecting their concentrations at exposure points, human exposure, potential risks, and their removal from drinking water. Many developing countries are faced with the challenge of reducing human exposure to heavy metals, mainly due to their limited economic capacities to use advanced technologies for heavy metal removal. This paper aims to review the state of research on heavy metals in drinking water in developing countries; understand their types and variability, sources, exposure, possible health effects, and removal; and analyze the factors contributing to heavy metals in drinking water. This study identifies the current challenges in developing countries, and future research needs to reduce the levels of heavy metals in drinking water. Copyright © 2016 Elsevier B.V. All rights reserved.
Using Naturally Occurring Radionuclides To Determine Drinking Water Age in a Community Water System.
Waples, James T; Bordewyk, Jason K; Knesting, Kristina M; Orlandini, Kent A
2015-08-18
Drinking water quality in a community water system is closely linked to the age of water from initial treatment to time of delivery. However, water age is difficult to measure with conventional chemical tracers; particularly in stagnant water, where the relationship between disinfectant decay, microbial growth, and water age is poorly understood. Using radionuclides that were naturally present in source water, we found that measured activity ratios of (90)Y/(90)Sr and (234)Th/(238)U in discrete drinking water samples of known age accurately estimated water age up to 9 days old (σest: ± 3.8 h, P < 0.0001, r(2) = 0.998, n = 11) and 25 days old (σest: ± 13.3 h, P < 0.0001, r(2) = 0.996, n = 12), respectively. Moreover, (90)Y-derived water ages in a community water system (6.8 × 10(4) m(3) d(-1) capacity) were generally consistent with water ages derived from an extended period simulation model. Radionuclides differ from conventional chemical tracers in that they are ubiquitous in distribution mains and connected premise plumbing. The ability to measure both water age and an analyte (e.g., chemical or microbe) in any water sample at any time allows for new insight into factors that control drinking water quality.
The U.S. Environmental Protection Agency (EPA) is currently evaluating package plant advanced oxidation process (AOP) systems to treat methyl tertiary butyl ether (MTBE) in drinking water supplies (e.g., surface water, groundwater). MTBE has been identified as a potential carcin...
Conventional plating methods were used to quantify heterotrophic bacteria from a drinking water distribution system. Three media, plate count agar (PCA), R2A agar and sheep blood agar (TSA-SB) were used to determine heterotrophic plate count (HPC) levels. Grab samples were collec...
A COST EVALUATION OF SMALL SYSTEM COMPLIANCE OPTIONS: POU AND POE TREATMENT UNITS
The challenges facing small drinking water systems were a major focus of the 1996 Amendments to the Safe Drinking Water Act (SDWA). One way Congress sought to help systems meet these challenges was by explicitly allowing systems to install point-of-use (POU) and point-of-entry (P...
Exposure to High Fluoride Drinking Water and Risk of Dental Fluorosis in Estonia
Indermitte, Ene; Saava, Astrid; Karro, Enn
2009-01-01
The purpose of this study was to assess exposure to drinking water fluoride and evaluate the risk of dental fluorosis among the Estonian population. The study covered all 15 counties in Estonia and 93.7% of population that has access to public water supplies. In Estonia groundwater is the main source for public water supply systems in most towns and rural settlements. The content of natural fluoride in water ranges from 0.01 to 7.20 mg/L. The exposure to different fluoride levels was assessed by linking data from previous studies on drinking water quality with databases of the Health Protection Inspectorate on water suppliers and the number of water consumers in water supply systems. Exposure assessment showed that 4% of the study population had excessive exposure to fluoride, mainly in small public water supplies in western and central Estonia, where the Silurian-Ordovician aquifer system is the only source of drinking water. There is a strong correlation between natural fluoride levels and the prevalence of dental fluorosis. Risk of dental fluorosis was calculated to different fluoride exposure levels over 1.5 mg/L. PMID:19440411
Heterotrophic plate count and consumer's health under special consideration of water softeners.
Hambsch, Beate; Sacré, Clara; Wagner, Ivo
2004-05-01
The phenomenon of bacterial growth in water softeners is well known since years. To upgrade the hygienic safety of water softeners, the German DIN Standard 19636 was developed, to assure that the distribution system could not be contaminated by these devices and that the drinking water to be used in the household still meets the microbiological standards according to the German drinking water guidelines, i.e. among others heterotrophic plate count (HPC) below 100 CFU/ml. Moreover, the standard for the water softeners includes a test for contamination with Pseudomonas aeruginosa which has to be disinfected during the regeneration phase. This is possible by sanitizing the resin bed during regeneration by producing chlorine. The results of the last 10 years of tests of water softeners according to DIN 19636 showed that it is possible to produce water softeners that comply with that standard. Approximately 60% of the tested models were accepted. P. aeruginosa is used as an indicator for potentially pathogenic bacteria being able to grow also in low nutrient conditions which normally prevail in drinking water. Like other heterotrophs, the numbers of P. aeruginosa increase rapidly as stagnation occurs. Normally P. aeruginosa is not present in the distributed drinking water. However, under certain conditions, P. aeruginosa can be introduced into the drinking water distribution system, for instance, during construction work. The occurrence of P. aeruginosa is shown in different cases in treatment plants, public drinking water systems and in-house installations. The compliance with DIN 19636 provides assurance that a water softener will not be a constant source of contamination, even if it is once inoculated with a potentially pathogenic bacterium like P. aeruginosa. Copyright 2003 Elsevier B.V.
Drinking water system treatment and contamination in Shatila Refugee Camp in Beirut, Lebanon.
Khoury, S; Graczyk, T; Burnham, G; Jurdi, M; Goldman, L
2016-11-02
Drinking water at Shatila Palestinian Refugee Camp in Beirut, Lebanon is of poor quality and unpredictably intermittent quantity. We aimed to characterize drinking water sources and contamination at Shatila and determine how drinking water can be managed to reduce community health burdens. We interviewed the Popular Committee, well owners, water vendors, water shopkeepers and preschool administrators about drinking water sources, treatment methods and the population served. Water samples from the sources and intermediaries were analysed for thermotolerant faecal coliforms (FCs), Giardia lamblia, Cryptosporidium parvum and microsporidia, using immunofluorescent antibody detection for G. lamblia and C. parvum, and chromotrope-2 stain for microsporidia. All drinking water sources were contaminated with FCs and parasites. FC counts (cfu/mL) were as follows: wells (35-300), water vendors (2-178), shops (30-300) and preschools (230-300). Responsible factors identified included: unskilled operators; improper maintenance of wells and equipment; lack of proper water storage and handling; and misperception of water quality. These factors must be addressed to improve water quality at Shatila and other refugee camps.
Overview of Causes and Control of Nitrification in Chloraminated Drinking Water Distribution Systems
This chapter provides an integrated overview of nitrification causes and control in chloraminated drinking water distribution systems, leading to an in-depth discussion of nitrification microbiology, monitoring, prevention, response, and engineering improvements in subsequent man...
Chien, C C; Kao, C M; Chen, C W; Dong, C D; Chien, H Y
2009-06-01
The appearance of assimilable organic carbon (AOC), microbial regrowth, disinfection by-products (DBPs), and pipe corrosion in drinking water distribution systems are among those major safe drinking water issues in many countries. The water distribution system of Cheng-Ching Lake Water Treatment Plant (CCLWTP) was selected in this study to evaluate the: (1) fate and transport of AOC, DBPs [e.g., trihalomethanes (THMs), haloacetic acids (HAAs)], and other organic carbon indicators in the selected distribution system, (2) correlations between AOC (or DBPs) and major water quality parameters [e.g. dissolved oxygen (DO), free residual chlorine, and bacteria, and (3) causes and significance of corrosion problems of the water pipes in this system. In this study, seasonal water samples were collected from 13 representative locations in the distribution system for analyses of AOC, DBPs, and other water quality indicators. Results indicate that residual free chlorine concentrations in the distribution system met the drinking water standards (0.2 to 1 mg l(-1)) established by Taiwan Environmental Protection Administration (TEPA). Results show that AOC measurements correlated positively with total organic carbon (TOC) and UV-254 (an organic indicator) values in this system. Moreover, AOC concentrations at some locations were higher than the 50 microg acetate-C l(-1) standard established by Taiwan Water Company. This indicates that the microbial regrowth might be a potential water quality problem in this system. Higher DO measurements (>5.7 mg l(-1)) might cause the aerobic biodegradation of THMs and HAAs in the system, and thus, low THMs (<0.035 mg l(-1)) and HAAs (<0.019 mg l(-1)) concentrations were observed at all sampling locations. Results from the observed negative Langelier Saturation Index (LSI) values, higher Ryznar Stability Index (RSI) values, and high Fe3+ concentrations at some pipe-end locations indicate that highly oxidative and corrosive conditions occurred. This reveals that pipe replacement should be considered at these locations. These findings would be helpful in managing the water distribution system for maintaining a safe drinking water quality.
[Drinking water supply in the Russian Federation: problems and ways of their solution].
Onishchenko, G G
2007-01-01
Russia having a fifth of the worldwide drinking water resources is faced with considerable difficulties in solving the problems associated with the safe and rational attitude towards water resources, in improving the technologies of drinking water purification and conditioning, in introducing new universal forms of supplying the population with high-quality portable water. Particular emphasis has been recently placed on the setting-up of an effective legal and normative base for the sanitary protection of water sources and the upgrading of the quality of drinking water. Regional (republican, territorial) drinking water supply programs have been worked out up to the period 2010 in 47 subjects of the Russian Federation, with the participation of sanitary-and-epidemiological surveillance systems and approved in accordance with the established procedures. The majority of administrative areas have district and town programs to implement high-priority measures for improving the water supple system. Safe drinking water supply is one of the major components of Russia's national security. Under the established conditions, even in case of the favorable financial position, this cannot be achieved by only engineering decisions (construction and modernization of water-supply networks, use of new equipment and breakthrough technologies). Water service as a type of water consumption is based on the general principles of natural resource management. Its safety should be combined with the strategic objective of water resources utilization and conservation in the catchment basins in the country as a whole.
A decision support system for drinking water production integrating health risks assessment.
Delpla, Ianis; Monteith, Donald T; Freeman, Chris; Haftka, Joris; Hermens, Joop; Jones, Timothy G; Baurès, Estelle; Jung, Aude-Valérie; Thomas, Olivier
2014-07-18
The issue of drinking water quality compliance in small and medium scale water services is of paramount importance in relation to the 98/83/CE European Drinking Water Directive (DWD). Additionally, concerns are being expressed over the implementation of the DWD with respect to possible impacts on water quality from forecast changes in European climate with global warming and further anticipated reductions in north European acid emissions. Consequently, we have developed a decision support system (DSS) named ARTEM-WQ (AwaReness Tool for the Evaluation and Mitigation of drinking Water Quality issues resulting from environmental changes) to support decision making by small and medium plant operators and other water stakeholders. ARTEM-WQ is based on a sequential risk analysis approach that includes consideration of catchment characteristics, climatic conditions and treatment operations. It provides a holistic evaluation of the water system, while also assessing human health risks of organic contaminants potentially present in treated waters (steroids, pharmaceuticals, pesticides, bisphenol-a, polychlorobiphenyls, polycyclic aromatic hydrocarbons, petrochemical hydrocarbons and disinfection by-products; n = 109). Moreover, the system provides recommendations for improvement while supporting decision making in its widest context. The tool has been tested on various European catchments and shows a promising potential to inform water managers of risks and appropriate mitigative actions. Further improvements should include toxicological knowledge advancement, environmental background pollutant concentrations and the assessment of the impact of distribution systems on water quality variation.
Guidotti, T L; Conway, J B
1984-10-01
The systems protecting the quality of drinking water in the United States are deteriorating. Many urban water and sewer systems are obsolete. Industrial wastes are imposing a burden on wastewater treatment facilities. In the U.S., outbreaks of water-borne disease are primarily limited to enteritis associated with viruses or Giardia. Issues in the contamination of drinking water by toxic substances include disposal practices, accidental contamination, agricultural runoff and chlorination byproducts. Physicians must support stringent enforcement of water quality standards.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
...; Disinfectants/Disinfection Byproducts, Chemical and Radionuclides; Microbial; and Public Water System...://www.epa.gov/epahome/dockets.htm . FOR FURTHER INFORMATION CONTACT: Matthew Reed, Drinking Water Protection Division, Office of Ground Water and Drinking Water, (4606M), Environmental Protection Agency...
SCALE-MODEL STUDIES OF MIXING IN DRINKING WATER STORAGE TANKS
Storage tanks and reservoirs are commonly used in drinking water distribution systems to equalize pumping requirements and operating pressures, and to provide emergency water for fire-fighting and pumping outages. Poor mixing in these structures can create pockets of older water...
NASA Astrophysics Data System (ADS)
Styani, E.; Dja'var, N.; Irawan, C.; Hanafi
2018-01-01
This study focuses on making equipment which is useful to process paddy water to be consumable as drinking water by using ozone-UVC and ultrafiltration. The equipment which is made by the process of ozone-UVC and ultrafiltration or reverse osmosis is driven by electric power generated from solar panels. In the experiment, reverse osmosis system with ozone-UVC reactor proves to be good enough in producing high quality drinking water.
Zhou, Xinyan; Zhang, Kejia; Zhang, Tuqiao; Li, Cong; Mao, Xinwei
2017-05-01
It is important for water utilities to provide esthetically acceptable drinking water to the public, because our consumers always initially judge the quality of the tap water by its color, taste, and odor (T&O). Microorganisms in drinking water contribute largely to T&O production and drinking water distribution systems (DWDS) are known to harbor biofilms and microorganisms in bulk water, even in the presence of a disinfectant. These microbes include T&O-causing bacteria, fungi, and algae, which may lead to unwanted effects on the organoleptic quality of distributed water. Importantly, the understanding of types of these microbes and their T&O compound-producing mechanisms is needed to prevent T&O formation during drinking water distribution. Additionally, new disinfection strategies and operation methods of DWDS are also needed for better control of T&O problems in drinking water. This review covers: (1) the microbial species which can produce T&O compounds in DWDS; (2) typical T&O compounds in DWDS and their formation mechanisms by microorganisms; (3) several common factors in DWDS which can influence the growth and T&O generation of microbes; and (4) several strategies to control biofilm and T&O compound formation in DWDS. At the end of this review, recommendations were given based on the conclusion of this review.
Continental United States Military Housing Inspections Southeast
2015-09-24
and safety, including focus on mold, asbestos , radon, lead-based paint, drinking water quality, and pest management. We conducted this inspection in...electrical system safety inspections. In addition, we inspected to EPA standards governing safe drinking water and toxic substances, radon, asbestos , and...inspections focused on mold, asbestos , radon, lead-based paint, drinking water quality, and pest management. We evaluated the associated plans and
77 FR 58132 - Public Water System Supervision Program Revision for the State of Utah
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-19
... accordance with the provisions of Section 1413 of the Safe Drinking Water Act (SDWA), 42 U.S.C. 300g-2... 2 Disinfectants and Disinfection Byproducts Rule that correspond to the National Primary Drinking... Administrator, c/o Robert Clement, Drinking Water Unit (8P-W-DW), U.S. EPA, Region 8, 1595 Wynkoop Street...
OVERVIEW OF RADIONUCLIDES IN DRINKING WATER SYSTEMS
Invited presentation at the 2007 National Rural Water Association National Conference, Philadelphia, PA, September 23-26, 2007. The presentation reviews the chemistry of radium and uranium in drinking water sources, treatment options, and guidelines for disposal. Presentation giv...
Elsäßer, Dennis; Ho, Johannes; Niessner, Reinhard; Tiehm, Andreas; Seidel, Michael
2018-04-01
Hygiene of drinking water is periodically controlled by cultivation and enumeration of indicator bacteria. Rapid and comprehensive measurements of emerging pathogens are of increasing interest to improve drinking water safety. In this study, the feasibility to detect bacteriophage PhiX174 as a potential indicator for virus contamination in large volumes of water is demonstrated. Three consecutive concentration methods (continuous ultrafiltration, monolithic adsorption filtration, and centrifugal ultrafiltration) were combined to concentrate phages stepwise from 1250 L drinking water into 1 mL. Heterogeneous asymmetric recombinase polymerase amplification (haRPA) is applied as rapid detection method. Field measurements were conducted to test the developed system for hygiene online monitoring under realistic conditions. We could show that this system allows the detection of artificial contaminations of bacteriophage PhiX174 in drinking water pipelines. Copyright © 2018 Elsevier Inc. All rights reserved.
An upper-bound assessment of the benefits of reducing perchlorate in drinking water.
Lutter, Randall
2014-10-01
The Environmental Protection Agency plans to issue new federal regulations to limit drinking water concentrations of perchlorate, which occurs naturally and results from the combustion of rocket fuel. This article presents an upper-bound estimate of the potential benefits of alternative maximum contaminant levels for perchlorate in drinking water. The results suggest that the economic benefits of reducing perchlorate concentrations in drinking water are likely to be low, i.e., under $2.9 million per year nationally, for several reasons. First, the prevalence of detectable perchlorate in public drinking water systems is low. Second, the population especially sensitive to effects of perchlorate, pregnant women who are moderately iodide deficient, represents a minority of all pregnant women. Third, and perhaps most importantly, reducing exposure to perchlorate in drinking water is a relatively ineffective way of increasing iodide uptake, a crucial step linking perchlorate to health effects of concern. © 2014 Society for Risk Analysis.
Integration of Aquifer Storage Transfer and Recovery and HACCP for Ensuring Drinking Water Quality
NASA Astrophysics Data System (ADS)
Lee, S. I.; Ji, H. W.
2015-12-01
The integration of ASTR (Aquifer Storage Transfer and Recovery) and HACCP (Hazard Analysis and Critical Control Point) is being attempted to ensure drinking water quality in a delta area. ASTR is a water supply system in which surface water is injected into a well for storage and recovered from a different well. During the process natural water treatment is achieved in the aquifer. ASTR has advantages over surface reservoirs in that the water is protected from external contaminants and free from water loss by evaporation. HACCP, originated from the food industry, can efficiently manage hazards and reduce risks when it is introduced to the drinking water production. The study area is the located in the Nakdong River Delta, South Korea. Water quality of this region has been deteriorated due to the increased pollution loads from the upstream cities and industrial complexes. ASTR equipped with HACCP system is suggested as a means to heighten the public trust in drinking water. After the drinking water supply system using ASTR was decomposed into ten processes, principles of HACCP were applied. Hazardous event analysis was conducted for 114 hazardous events and nine major hazardous events were identified based on the likelihood and the severity assessment. Potential risk of chemical hazards, as a function of amounts, travel distance and toxicity, was evaluated and the result shows the relative threat a city poses to the drinking water supply facility. Next, critical control points were determined using decision tree analysis. Critical limits, maximum and/or minimum values to which biological, chemical or physical parameters must be controlled, were established. Other procedures such as monitoring, corrective actions and will be presented.
Contribution of Drinking Water Softeners to Daily Phosphate Intake in Slovenia
Jereb, Gregor; Poljšak, Borut; Eržen, Ivan
2017-01-01
The cumulative phosphate intake in a typical daily diet is high and, according to several studies, already exceeds recommended values. The exposure of the general population to phosphorus via drinking water is generally not known. One of the hidden sources of phosphorus in a daily diet is sodium polyphosphate, commonly used as a drinking water softener. In Slovenia, softening of drinking water is carried out exclusively within the internal (household) drinking water supply systems to prevent the accumulation of limescale. The aim of the study was to determine the prevalence of sodium phosphates in the drinking water in Slovenia in different types of buildings, to determine residents’ awareness of the presence of chemical softeners in their drinking water, and to provide an exposure assessment on the phosphorus intake from drinking water. In the current study, the presence of phosphates in the samples of drinking water was determined using a spectrophotometric method with ammonium molybdate. In nearly half of the samples, the presence of phosphates as water softeners was confirmed. The measured concentrations varied substantially from 0.2 mg PO4/L to 24.6 mg PO4/L. Nearly 70% of the respondents were not familiar with the exact data on water softening in their buildings. It follows that concentrations of added phosphates should be controlled and the consumers should be informed of the added chemicals in their drinking water. The health risks of using sodium polyphosphate as a drinking water softener have not been sufficiently investigated and assessed. It is highly recommended that proper guidelines and regulations are developed and introduced to protect human health from adverse effects of chemicals in water intended for human consumption. PMID:28984825
Contribution of Drinking Water Softeners to Daily Phosphate Intake in Slovenia.
Jereb, Gregor; Poljšak, Borut; Eržen, Ivan
2017-10-06
The cumulative phosphate intake in a typical daily diet is high and, according to several studies, already exceeds recommended values. The exposure of the general population to phosphorus via drinking water is generally not known. One of the hidden sources of phosphorus in a daily diet is sodium polyphosphate, commonly used as a drinking water softener. In Slovenia, softening of drinking water is carried out exclusively within the internal (household) drinking water supply systems to prevent the accumulation of limescale. The aim of the study was to determine the prevalence of sodium phosphates in the drinking water in Slovenia in different types of buildings, to determine residents' awareness of the presence of chemical softeners in their drinking water, and to provide an exposure assessment on the phosphorus intake from drinking water. In the current study, the presence of phosphates in the samples of drinking water was determined using a spectrophotometric method with ammonium molybdate. In nearly half of the samples, the presence of phosphates as water softeners was confirmed. The measured concentrations varied substantially from 0.2 mg PO4/L to 24.6 mg PO4/L. Nearly 70% of the respondents were not familiar with the exact data on water softening in their buildings. It follows that concentrations of added phosphates should be controlled and the consumers should be informed of the added chemicals in their drinking water. The health risks of using sodium polyphosphate as a drinking water softener have not been sufficiently investigated and assessed. It is highly recommended that proper guidelines and regulations are developed and introduced to protect human health from adverse effects of chemicals in water intended for human consumption.
NASA Astrophysics Data System (ADS)
Spangemacher, Lars; Fröhlich, Siegmund; Buse, Hauke
2017-11-01
Water is an indispensable resource for many purposes and good drinking water quality is essential for mankind. This article is supposed to show the need for mobile water treatment systems and therefore to give an overview of different mobile drinking water systems and the technologies available for obtaining good water quality. The aim is to develop a simple to operate water treatment system with few processing stages such as multi-cyclone-cartridge and reverse osmosis with energy recuperation, while the focus is set on modeling and optimizing of hydrocyclone systems as the first treatment stage.
URBAN DRINKING WATER DISTRIBUTION SYSTEMS: A U.S. PERSPECTIVE
This paper will examine several case studies that illustrate the critical role drinking water treatment and distribution systems play in protecting public health. It will also present a case study that documents the dramatic impact that the regulations promulgated under the Safe...
ENVIRONMENTAL POLLUTION CONTROL ALTERNATIVES: DRINKING WATER TREATMENT FOR SMALL COMMUNITIES
This document provides information for small system owners, operators, managers, and local decision makers, such as town officials, regarding drinking water treatment requirements and the treatment technologies suitable for small systems. t is not intended to be a comprehensive m...
SMALL DRINKING WATER SYSTEM PEER REVIEW PROGRAM
The United South and Eastern Tribes, Inc., which is made up of twenty-four (24) tribes, ranging in location, geographically, from Maine to Texas, AND three (3) states, Mississippi, Kentucky, and Georgia, participated in a program, "The Small Drinking Water System Peer Review Prog...
Banzhaf, Stefan; Filipovic, Marko; Lewis, Jeffrey; Sparrenbom, Charlotte J; Barthel, Roland
2017-04-01
Perfluoroalkyl and polyfluoroalkyl substances (PFASs) are found in aquatic systems, flora, and fauna worldwide. These potentially harmful compounds are also frequently detected in Sweden and have already resulted in severe problems for public drinking water supply, i.e., some wells had to be closed due to high PFAS concentrations both in raw water and produced drinking water. Knowledge on PFAS occurrence in Sweden is still quite low, although monitoring is currently ongoing. This work describes potential sources for PFASs to enter the drinking water supply in Sweden and compares different occurrences of PFASs in raw and drinking water in the country. Moreover, the monitoring history, the legal situation, and remediation actions taken are presented. Finally, future challenges and the way forward in Sweden are discussed.
This presentation will provide an overview of drinking water research being conducted by the National Risk Management Research Laboratory (NRMRL) of the U.S. EPA. The Water Supply and Water Resources Division (WSWRD) is an internationally known water research organization establi...
78 FR 18336 - Public Water System Supervision Program Approval for the State of Michigan
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... comply with the National Primary Drinking Water Regulations, including the Ground Water Rule, the Stage 2 Disinfectants and Disinfection Byproducts Rule, the Long-Term 2 Enhanced Surface Water Treatment Rule, the Lead... following offices: Michigan Department of Environmental Quality, Office of Drinking Water and Municipal...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2012 CFR
2012-07-01
... water pressure in all parts of the distribution system; (4) Filtration and/or disinfection of surface water, as described in subpart H, or disinfection of ground water using strong oxidants such as chlorine... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS National Primary Drinking...
SSWR Water Systems Project 2: Next Steps – Technology Advances
EPA is responsible for protecting America’s water resources under the Clean Water Act (CWA) and for ensuring that the Nation’s drinking water is safe under the Safe Drinking Water Act (SDWA). Further, it is the responsibility of EPA to conduct research and analyses t...
Morgan, Matthew J; Halstrom, Samuel; Wylie, Jason T; Walsh, Tom; Kaksonen, Anna H; Sutton, David; Braun, Kalan; Puzon, Geoffrey J
2016-03-15
Free-living amoebae, such as Naegleria fowleri, Acanthamoeba spp., and Vermamoeba spp., have been identified as organisms of concern due to their role as hosts for pathogenic bacteria and as agents of human disease. In particular, N. fowleri is known to cause the disease primary amoebic meningoencephalitis (PAM) and can be found in drinking water systems in many countries. Understanding the temporal dynamics in relation to environmental and biological factors is vital for developing management tools for mitigating the risks of PAM. Characterizing drinking water systems in Western Australia with a combination of physical, chemical and biological measurements over the course of a year showed a close association of N. fowleri with free chlorine and distance from treatment over the course of a year. This information can be used to help design optimal management strategies for the control of N. fowleri in drinking-water-distribution systems.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of biological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some biological agents, but data gaps remain. Data on bacterial spore persistence on common water infrastructure materials such as iron and cement-mortar lined iron show that spores can be persistent for weeks after contamination. Decontamination data show that common disinfectants such as free chlorine have limited effectiveness. Decontamination results with germinant and alternate disinfectants such as chlorine dioxide are more promising. Persistence and decontamination data were collected on vegetative bacteria, such as coliforms, Legionella and Salmonella. Vegetative bacteria are less persistent than spores and more susceptible to disinfection, but the surfaces and water quality conditions in many studies were only marginally related to drinking water systems. However, results of real-world case studies on accidental contamination of water systems with E. coli and Salmonella contamination show that flushing and chlorination can help return a water system to service. Some viral persistence data were found, but decontamination data were lacking. Future research suggestions focus on expanding the available biological persistence data to other common infrastructure materials. Further exploration of non-traditional drinking water disinfectants is recommended for future studies. Published by Elsevier Ltd.
Weinmeyer, Richard; Norling, Annalise; Kawarski, Margaret; Higgins, Estelle
2017-10-01
In 1974, President Gerald Ford signed into law the Safe Drinking Water Act, the first piece of legislation of its kind to provide a comprehensive regulatory framework for overseeing the nation's drinking water supply. The law has proven instrumental in setting standards for ensuring that the US population can access drinking water that is safe. However, the law delegates much of its monitoring requirements to states, creating, at times, a confusing and complicated system of standards that must be adhered to and enforced. Although it has proven valuable in the safety standards it specifies, the law's administration and enforcement poses tremendous challenges. © 2017 American Medical Association. All Rights Reserved.
Impact of disinfection on drinking water biofilm bacterial community.
Mi, Zilong; Dai, Yu; Xie, Shuguang; Chen, Chao; Zhang, Xiaojian
2015-11-01
Disinfectants are commonly applied to control the growth of microorganisms in drinking water distribution systems. However, the effect of disinfection on drinking water microbial community remains poorly understood. The present study investigated the impacts of different disinfectants (chlorine and chloramine) and dosages on biofilm bacterial community in bench-scale pipe section reactors. Illumina MiSeq sequencing illustrated that disinfection strategy could affect both bacterial diversity and community structure of drinking water biofilm. Proteobacteria tended to predominate in chloraminated drinking water biofilms, while Firmicutes in chlorinated and unchlorinated biofilms. The major proteobacterial groups were influenced by both disinfectant type and dosage. In addition, chloramination had a more profound impact on bacterial community than chlorination. Copyright © 2015. Published by Elsevier B.V.
This project is a collaborative drinking water research study. EPA is evaluating water samples collected by PWS operators in order to investigate relationships between bromide in source water and the formation of brominated DBPs in finished drinking water. This study will includ...
Donovan, Ariel R; Adams, Craig D; Ma, Yinfa; Stephan, Chady; Eichholz, Todd; Shi, Honglan
2016-02-01
One of the most direct means for human exposure to nanoparticles (NPs) released into the environment is drinking water. Therefore, it is critical to understand the occurrence and fate of NPs in drinking water systems. The objectives of this study were to develop rapid and reliable analytical methods and apply them to investigate the fate and transportation of NPs during drinking water treatments. Rapid single particle ICP-MS (SP-ICP-MS) methods were developed to characterize and quantify titanium-containing, titanium dioxide, silver, and gold NP concentration, size, size distribution, and dissolved metal element concentration in surface water and treated drinking water. The effectiveness of conventional drinking water treatments (including lime softening, alum coagulation, filtration, and disinfection) to remove NPs from surface water was evaluated using six-gang stirrer jar test simulations. The selected NPs were nearly completely (97 ± 3%) removed after lime softening and alum coagulation/activated carbon adsorption treatments. Additionally, source and drinking waters from three large drinking water treatment facilities utilizing similar treatments with the simulation test were collected and analyzed by the SP-ICP-MS methods. Ti-containing particles and dissolved Ti were present in the river water samples, but Ag and Au were not present. Treatments used at each drinking water treatment facility effectively removed over 93% of the Ti-containing particles and dissolved Ti from the source water. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Drinking Water Disparities Framework: On the Origins and Persistence of Inequities in Exposure
Balazs, Carolina L.; Ray, Isha
2014-01-01
With this article, we develop the Drinking Water Disparities Framework to explain environmental injustice in the context of drinking water in the United States. The framework builds on the social epidemiology and environmental justice literatures, and is populated with 5 years of field data (2005–2010) from California’s San Joaquin Valley. We trace the mechanisms through which natural, built, and sociopolitical factors work through state, county, community, and household actors to constrain access to safe water and to financial resources for communities. These constraints and regulatory failures produce social disparities in exposure to drinking water contaminants. Water system and household coping capacities lead, at best, to partial protection against exposure. This composite burden explains the origins and persistence of social disparities in exposure to drinking water contaminants. PMID:24524500
Schaider, Laurel A; Ackerman, Janet M; Rudel, Ruthann A
2016-03-15
Domestic drinking water wells serve 44 million people in the US and are common globally. They are often located in areas served by onsite wastewater treatment systems, including septic systems, which can be sources of biological and chemical pollutants to groundwater. In this study we tested 20 domestic drinking water wells in a sand and gravel aquifer on Cape Cod, Massachusetts, USA, for 117 organic wastewater compounds (OWCs) and for inorganic markers of septic system impact. We detected 27 OWCs, including 12 pharmaceuticals, five per- and polyfluoroalkyl substances (PFASs), four organophosphate flame retardants, and an artificial sweetener (acesulfame). Maximum concentrations of several PFASs and pharmaceuticals were relatively high compared to public drinking water supplies in the US. The number of detected OWCs and total concentrations of pharmaceuticals and of PFASs were positively correlated with nitrate, boron, and acesulfame and negatively correlated with well depth. These wells were all located in areas served exclusively by onsite wastewater treatment systems, which are likely the main source of the OWCs in these wells, although landfill leachate may also be a source. Our results suggest that current regulations to protect domestic wells from pathogens in septic system discharges do not prevent OWCs from reaching domestic wells, and that nitrate, a commonly measured drinking water contaminant, is a useful screening tool for OWCs in domestic wells. Nitrate concentrations of 1mg/L NO3-N, which are tenfold higher than local background and tenfold lower than the US federal drinking water standard, were associated with wastewater impacts from OWCs in this study. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
40 CFR 142.10 - Requirements for a determination of primary enforcement responsibility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS... enforcement responsibility. A State has primary enforcement responsibility for public water systems in the...: (a) Has adopted drinking water regulations which are no less stringent than the national primary...
40 CFR 142.10 - Requirements for a determination of primary enforcement responsibility.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS... enforcement responsibility. A State has primary enforcement responsibility for public water systems in the...: (a) Has adopted drinking water regulations which are no less stringent than the national primary...
40 CFR 142.10 - Requirements for a determination of primary enforcement responsibility.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS... enforcement responsibility. A State has primary enforcement responsibility for public water systems in the...: (a) Has adopted drinking water regulations which are no less stringent than the national primary...
Mo, Weiwei; Nasiri, Fuzhan; Eckelman, Matthew J; Zhang, Qiong; Zimmerman, Julie B
2010-12-15
A sustainable supply of both energy and water is critical to long-term national security, effective climate policy, natural resource sustainability, and social wellbeing. These two critical resources are inextricably and reciprocally linked; the production of energy requires large volumes of water, while the treatment and distribution of water is also significantly dependent upon energy. In this paper, a hybrid analysis approach is proposed to estimate embodied energy and to perform a structural path analysis of drinking water supply systems. The applicability of this approach is then tested through a case study of a large municipal water utility (city of Kalamazoo) in the Great Lakes region to provide insights on the issues of water-energy pricing and carbon footprints. Kalamazoo drinking water requires approximately 9.2 MJ/m(3) of energy to produce, 30% of which is associated with indirect inputs such as system construction and treatment chemicals.
Groundwater quality in the glacial aquifer system, United States
Stackelberg, Paul E.
2017-12-07
Groundwater provides nearly 50 percent of the Nation’s drinking water. To help protect this vital resource, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Project assesses groundwater quality in aquifers that are important sources of drinking water (Burow and Belitz, 2014). The glacial aquifer system constitutes one of the important areas being evaluated.
Mel'tser, A V; Erastova, N V; Kiselev, A V
2013-01-01
Providing population with quality drinking water--one of the priority tasks of the state policy aimed at maintaining the health of citizens. Hygienic rating of the drinking water quality envisages requirements to assurance its safety in the epidemiological and radiation relations, harmlessness of chemical composition and good organoleptic properties. There are numerous data proving the relationship between the chemical composition of drinking water and human health, and therefore the issue of taking a hygienically sound measures to improve the efficiency of water treatment has more and more priority. High water quality--the result of complex solution of tasks, including an integral approach to assessment of the quality of drinking water the use of hygienically sound decisions in the modernization of water treatment systems. The results of the integral assessment of drinking water on the properties of harmlessness have shown its actuality in the development and implementation of management decisions. The use of the spatial characteristics of integrated indices permits to visualize changes in the quality of drinking water in all stages of production and transportation from the position of health risks, evaluate the effectiveness of technological solutions and set priorities for investing.
Preliminary evaluation of the Highland Rim aquifer system in Tennessee for receiving injected wastes
Bradley, M.W.
1986-01-01
The EPA has authority under the Safe Drinking Water Act to protect underground sources of drinking water from contamination by deep well injection. An aquifer, however, may be exempted from protection and used for injected wastes where the aquifer meets criteria established in the Agency 's Underground Injection Control program. The Highland Rim aquifer system in Tennessee consists of Mississippian age carbonate rocks and occurs from the Valley and Ridge of East Tennessee to west of the Tennessee River. This aquifer contains potable water and is an important source of drinking water for municipal and domestic supplies on the Highland Rim. The Highland Rim aquifer system under parts of the Cumberland Plateau is not currently used as a source of drinking water and is not expected to be used in the future. These areas meet parts of the EPA 's Underground Injection Control criteria for exempting aquifers to receive injected waste. (Author 's abstract)
Yekta, Tahereh Sadeghi; Khazaei, Mohammad; Nabizadeh, Ramin; Mahvi, Amir Hossein; Nasseri, Simin; Yari, Ahmad Reza
2015-01-01
Hierarchical distance-based fuzzy multi-criteria group decision making was served as a tool to evaluate the drinking water supply systems of Qom, a semi-arid city located in central part of Iran. A list of aspects consisting of 6 criteria and 35 sub-criteria were evaluated based on a linguistic term set by five decision-makers. Four water supply alternatives including "Public desalinated distribution system", "PET Bottled Drinking Water", "Private desalinated water suppliers" and "Household desalinated water units" were assessed based on criteria and sub-criteria. Data were aggregated and normalized to apply Performance Ratings of Alternatives. Also, the Performance Ratings of Alternatives were aggregated again to achieve the Aggregate Performance Ratings. The weighted distances from ideal solution and anti-ideal solution were calculated after secondary normalization. The proximity of each alternative to the ideal solution was determined as the final step. The alternatives were ranked based on the magnitude of ideal solutions. Results showed that "Public desalinated distribution system" was the most appropriate alternative to supply the drinking needs of Qom population. Also, "PET Bottled Drinking Water" was the second acceptable option. A novel classification of alternatives to satisfy the drinking water requirements was proposed which is applicable for the other cities located in semi-arid regions of Iran. The health issues were considered as independent criterion, distinct from the environmental issues. The constraints of high-tech alternatives were also considered regarding to the level of dependency on overseas.
Bee guide to complying with the Safe Drinking Water Act. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garland, J.G.; Acker, A.M.
This report provides current information on the Safe Drinking Water Act and recent amendments. The report describes the evolution of the Safe Drinking Water Act and the responsibilities of base personnel involved in compliance with the Act. It also describes the monitoring requirements, analytical requirements, best available technology for controlling contaminants, and public notification requirements for regulated contaminants. The appendixes include proposed contaminants and state water quality agencies. Each Air Force public water distribution system (PWDS) must comply with the SDWA, and the National Primary Drinking Water Regulations (NPDWRs). In the United States and its territories, the provisions of themore » SDWA and the NPDWRs are enforced by the states except in the few instances in which the state has not been delegated primary enforcement responsibility (primacy) by the EPA. States that have primacy may establish drinking water regulations, monitoring schedules, and reporting requirements more stringent than, or in addition to, those in the NPDWRs. Air Force public water systems in these states are required to comply with these additional requirements as well as federal enforcement actions as carried out by the EPA Regional Office.« less
Two Koch Membrane Systems HF-82-35-PMPW ultrafiltration membrane cartridges were tested for removal of viruses, bacteria, and protozoan cysts at NSF’s Drinking Water Treatment Systems Laboratory. The ETV testing was conducted as part of a series of evaluations of the Expeditiona...
Point-of-entry drinking-water treatment systems for Superfund applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambers, C.D.; Janszen, T.A.
1989-06-01
The U.S. Environmental Protection Agency (EPA) and State Superfund agencies need a technical manual to assist their personnel in the selection of an effective drinking-water treatment system for individual households in areas where the drinking water has been adversely affected by Superfund site contaminants and no other alternative water supply is available or feasible. Commercially available water treatment systems for individual households are of two basic types: point-of-use (POU) and point-of-entry (POE). A POU device consists of equipment applied to selected water taps to reduce contaminants at each tap. A POE device consists of equipment to reduce the contaminants inmore » the water distributed throughout the entire structure of a house. The study was initiated to collect monitoring, operation and maintenance, performance, and design data on existing Superfund POE water-treatment systems. Evaluation of the collected data showed that the existing data are not sufficient for the preparation of a technical assistance document to meet the objectives of EPA and State Superfund personnel.« less
Nanofiltration Membranes for Removal of Color and Pathogens in Small Public Drinking Water Sources
Small public water supplies that use surface water as a source for drinking water are frequently faced with elevated levels of color and natural organic matter (NOM) that are precursors for chlorinated disinfection byproduct (DBP) formation. Nanofiltration (NF) systems can preve...
EPA's Office of Research and Development and Office of Water/Water Security Division have jointly developed a Response Protocol Toolbox (RPTB) to address the complex, multi-faceted challenges of a water utility's planning and response to intentional contamination of drinking wate...
40 CFR 142.10 - Requirements for a determination of primary enforcement responsibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... drinking water regulations (NPDWRs) in effect under part 141 of this chapter; (b) Has adopted and is... PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS... enforcement responsibility. A State has primary enforcement responsibility for public water systems in the...
40 CFR 142.10 - Requirements for a determination of primary enforcement responsibility.
Code of Federal Regulations, 2012 CFR
2012-07-01
... drinking water regulations (NPDWRs) in effect under part 141 of this chapter; (b) Has adopted and is... PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS... enforcement responsibility. A State has primary enforcement responsibility for public water systems in the...
The Inhibition Of Pb(IV) Oxide Formation In Chlorinated Water By Orthophosphate
Historically, understanding lead solubility and its control in drinking water has been based on Pb(II) chemistry. Unfortunately, there is very little information available regarding the nature of Pb(IV) oxides in finished drinking water and water distribution systems, and the co...
OPERATION OF WATER DISTRIBUTION SYSTEMS TO IMPROVE WATER QUALITY
The quality of drinking water can change between the discharge from the treatment plant and the point of consumption. In order to study these changes in a systematic manner a Cooperative Agreement was initiated between EPA's Drinking Water Research Division and the North Penn Wat...
OPERATION OF WATER QUALITY DISTRIBUTION SYSTEMS TO IMPROVE WATER QUALITY
The quality of drinking water can change between the discharge from the treatment plant and the point of consumption. n order to study these changes in a systematic manner a Cooperative Agreement was initiated between EPA's Drinking Water Research Division and the North Penn Wate...
Dehghani, Mohammad Hadi; Haghighat, Gholam Ali; Yousefi, Mahmood
2018-08-01
Fluoride is a natural element among minerals, geochemical sediments and natural water systems which is entered to body chain by drinking water. Groundwater is the main and the best source of drinking water in southern areas of Iran especially in the cities of Lar and Gerash (Fars province). So due to the health significance fluoride including dental and skeletal fluorosis, fertility, abortion and thyroid diseases, etc., measuring has high importance in the water resources of this region of Iran. Fluoride concentration was 0.35-3.46 mg/L and 78.26% drinking water sources contains fluoride concentration above the WHO guideline.
Monitoring bacterial contamination of piped water supply in rural coastal Bangladesh.
Ahsan, Md Sabbir; Akber, Md Ali; Islam, Md Atikul; Kabir, Md Pervez; Hoque, Md Ikramul
2017-10-31
Safe drinking water is scarce in southwest coastal Bangladesh because of unavailability of fresh water. Given the high salinity of both groundwater and surface water in this area, harvested rainwater and rain-fed pond water became the main sources of drinking water. Both the government and non-government organizations have recently introduced pipe water supply in the rural coastal areas to ensure safe drinking water. We assessed the bacteriological quality of water at different points along the piped water distribution system (i.e., the source, treatment plant, household taps, street hydrants, and household storage containers) of Mongla municipality under Mongla Upazila in Bagerhat district. Water samples were collected at 2-month interval from May 2014 to March 2015. Median E. coli and total coliform counts at source, treatment plant, household taps, street hydrants, and household storage containers were respectively 225, 4, 7, 7, and 15 cfu/100 ml and 42,000, 545, 5000, 6150, and 18,800 cfu/100 ml. Concentrations of both of the indicator bacteria reduced after treatment, although it did not satisfy the WHO drinking water standards. However, re-contamination in distribution systems and household storage containers indicate improper maintenance of distribution system and lack of personal hygiene.
Pal, Amit; Jayamani, Jayagandan; Prasad, Rajendra
2014-09-01
Recent seminal studies have established neurodegeneration, cognitive waning and/or β-amyloid deposition due to chronic copper intoxication via drinking water in healthy animals; henceforth, fuelling the debate all again over the safe levels of copper in the drinking water. This review encompasses the contemporary imperative animal studies in which the effect of chronic copper toxicity (especially via drinking water) was evaluated on the central nervous system and memory of uncompromised animals along with discussing the future perspectives. Copyright © 2014 Elsevier Inc. All rights reserved.
Oh, Jin-Aa; Shin, Ho-Sang
2015-05-22
An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to determine the level of hydrazine in drinking water. The method is based on the derivatization of hydrazine with naphthalene-2,3-dicarboxaldehyde (NDA) in water. The optimum conditions for UPLC-MS/MS detection were determined as follows: derivatization reagent dosage, 50mg/L of NDA; pH 2; and reaction time, 1min; room temperature. The formed derivative was injected into an LC system without extraction or purification procedures. Under the established conditions, the method was used to detect hydrazine in raw drinking water and chlorinated drinking water. The limits of detection and quantification for hydrazine in drinking water were 0.003μg/L and 0.01μg/L, respectively. The accuracy was in the range of 97-104%, and precision, expressed as relative standard deviation, was less than 9% in drinking water. Hydrazine was detected at a concentration of 0.13μg/L in one sample among 24 raw drinking water samples and in a range of 0.04-0.45μg/L in three samples among 24 chlorinated drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Risk management for assuring safe drinking water.
Hrudey, Steve E; Hrudey, Elizabeth J; Pollard, Simon J T
2006-12-01
Millions of people die every year around the world from diarrheal diseases much of which is caused by contaminated drinking water. By contrast, drinking water safety is largely taken for granted by many citizens of affluent nations. The ability to drink water that is delivered into households without fear of becoming ill may be one of the key defining characteristics of developed nations in relation to the majority of the world. Yet there is well-documented evidence that disease outbreaks remain a risk that could be better managed and prevented even in affluent nations. A detailed retrospective analysis of more than 70 case studies of disease outbreaks in 15 affluent nations over the past 30 years provides the basis for much of our discussion [Hrudey, S.E. and Hrudey, E.J. Safe Drinking Water--Lessons from Recent Outbreaks in Affluent Nations. London, UK: IWA Publishing; 2004.]. The insights provided can assist in developing a better understanding within the water industry of the causes of drinking water disease outbreaks, so that more effective preventive measures can be adopted by water systems that are vulnerable. This preventive feature lies at the core of risk management for the provision of safe drinking water.
Power Plant Bromide Discharges and Downstream Drinking Water Systems in Pennsylvania.
Good, Kelly D; VanBriesen, Jeanne M
2017-10-17
Coal-fired power plants equipped with wet flue gas desulfurization (FGD) systems have been implicated in increasing bromide levels and subsequent increases in disinfection byproducts at downstream drinking water plants. Bromide was not included as a regulated constituent in the recent steam electric effluent limitations guidelines and standards (ELGs) since the U.S. EPA analysis suggested few drinking water facilities would be affected by bromide discharges from power plants. The present analysis uses a watershed approach to identify Pennsylvania drinking water intakes downstream of wet FGD discharges and to assess the potential for bromide discharge effects. Twenty-two (22) public drinking water systems serving 2.5 million people were identified as being downstream of at least one wet FGD discharge. During mean August conditions (generally low-flow, minimal dilution) in receiving rivers, the median predicted bromide concentrations contributed by wet FGD at Pennsylvania intake locations ranged from 5.2 to 62 μg/L for the Base scenario (including only natural bromide in coal) and from 16 to 190 μg/L for the Bromide Addition scenario (natural plus added bromide for mercury control); ranges depend on bromide loads and receiving stream dilution capacity.
Cope, Jennifer R.; Ratard, Raoult C.; Hill, Vincent R.; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S.; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A.; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N.; Akingbola, Olugbenga A.; Ritter, Jana; Xiong, Zhenggang; da Silva, Alexandre; Roellig, Dawn; Van Dyke, Russell; Stern, Harlan; Xiao, Lihua; Beach, Michael J.
2015-01-01
Background Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri–containing water enters the nose, typically during swimming, and N. fowleri migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old child died of meningoencephalitis of unknown etiology in a Louisiana hospital. Methods Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Results Based on testing of CSF and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri were identified in water samples from both the home and the water distribution system. Conclusions This case is the first reported PAM death associated with culturable N. fowleri in tap water from a U.S. treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern tier states with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. PMID:25595746
Cope, Jennifer R; Ratard, Raoult C; Hill, Vincent R; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N; Akingbola, Olugbenga A; Ritter, Jana M; Xiong, Zhenggang; da Silva, Alexandre J; Roellig, Dawn; Van Dyke, Russell B; Stern, Harlan; Xiao, Lihua; Beach, Michael J
2015-04-15
Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri-containing water enters the nose, typically during swimming, and migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old boy died of meningoencephalitis of unknown etiology in a Louisiana hospital. Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Based on testing of cerebrospinal fluid and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri was identified in water samples from both the home and the water distribution system. This case is the first reported PAM death associated with culturable N. fowleri in tap water from a US treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern states, with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Using naturally occurring radionuclides to determine drinking water age in a community water system
Waples, James T.; Bordewyk, Jason K.; Knesting, Kristina M.; ...
2015-07-22
Drinking water quality in a community water system is closely linked to the age of water from initial treatment to time of delivery. However, water age is difficult to measure with conventional chemical tracers; particularly in stagnant water, where the relationship between disinfectant decay, microbial growth, and water age is poorly understood. Using radionuclides that were naturally present in source water, we found that measured activity ratios of 90Y/ 90Sr and 234Th/ 238U in discrete drinking water samples of known age accurately estimated water age up to 9 days old (σ est: ± 3.8 h, P < 0.0001, r 2more » = 0.998, n = 11) and 25 days old (σ est: ± 13.3 h, P < 0.0001, r 2 = 0.996, n = 12), respectively. Moreover, 90Y-derived water ages in a community water system (6.8 × 10 4 m 3 d –1 capacity) were generally consistent with water ages derived from an extended period simulation model. Radionuclides differ from conventional chemical tracers in that they are ubiquitous in distribution mains and connected premise plumbing. The ability to measure both water age and an analyte (e.g., chemical or microbe) in any water sample at any time allows for new insight into factors that control drinking water quality.« less
Using naturally occurring radionuclides to determine drinking water age in a community water system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waples, James T.; Bordewyk, Jason K.; Knesting, Kristina M.
Drinking water quality in a community water system is closely linked to the age of water from initial treatment to time of delivery. However, water age is difficult to measure with conventional chemical tracers; particularly in stagnant water, where the relationship between disinfectant decay, microbial growth, and water age is poorly understood. Using radionuclides that were naturally present in source water, we found that measured activity ratios of 90Y/ 90Sr and 234Th/ 238U in discrete drinking water samples of known age accurately estimated water age up to 9 days old (σ est: ± 3.8 h, P < 0.0001, r 2more » = 0.998, n = 11) and 25 days old (σ est: ± 13.3 h, P < 0.0001, r 2 = 0.996, n = 12), respectively. Moreover, 90Y-derived water ages in a community water system (6.8 × 10 4 m 3 d –1 capacity) were generally consistent with water ages derived from an extended period simulation model. Radionuclides differ from conventional chemical tracers in that they are ubiquitous in distribution mains and connected premise plumbing. The ability to measure both water age and an analyte (e.g., chemical or microbe) in any water sample at any time allows for new insight into factors that control drinking water quality.« less
INTERACTIVE WORKSHOP ON ARSENIC REMOVAL FROM DRINKING WATER
In 2005, EPA's Office of Water and Office of Research and Development collaborated to present eleven arsenic training events. The workshops provided in-depth treatment technology training to help those affected; state drinking water staff, design engineers, system owners and cert...
MICROBIAL GROWTH IN DISTRIBUTION SYSTEMS
Drinking water is not sterile. Microbes are commonly found in delivered water. Some survive treatment, while others may be introduced due to cross connections, line breaks, or by other means. Biofilm forms in drinking water pipes when bacteria and other organisms adhere to pip...
ARE WE MONITORING IN THE RIGHT PLACES FOR INORGANICS AND RADIONUCLIDES?
A review of numerous drinking water and geochemical investigations combined with recent studies of pipe deposits and water treatment materials suggests that many regulated drinking water constituents are not conservative in the distribution system. Examples are arsenic, aluminum...
MODELING CONTAMINANT PROPAGATION IN DISTRIBUTION SYSTEMS.
The Safe Drinking Water Act and its Amendments (SDWAA) will pose a massive hallenge for the drinking water industry in the United States. As the SDWAA regulations reach implementation, increasing effort will be devoted to understanding the facctors causing deterioration of water...
Klanicova, Barbora; Seda, Jaromir; Slana, Iva; Slany, Michal; Pavlik, Ivo
2013-12-01
Mycobacteria are widely present in diverse aquatic habitats, where they can survive for months or years while some species can even proliferate. The resistance of different mycobacterial species to disinfection methods like chlorination or ozonation could result in their presence in the final tap water of consumers. In this study, the culture method, Mycobacterium tuberculosis complex conventional duplex PCR for detection of non-tuberculous mycobacteria (NTM) and quantitative real-time PCR (qPCR) to detect three subspecies of M. avium species (M. a. avium, M. a. hominissuis, and M. a. paratuberculosis) were used to trace their possible path of transmission from the watershed through the reservoir and drinking water plant to raw drinking water and finally to households. A total of 124 samples from four drinking water supply systems in the Czech Republic, 52 dam sediments, 34 water treatment plant sludge samples, and 38 tap water household sediments, were analyzed. NTM of 11 different species were isolated by culture from 42 (33.9 %) samples; the most prevalent were M. gordonae (16.7 %), M. triplex (14.3 %), M. lentiflavum (9.5 %), M. a. avium (7.1 %), M. montefiorenase (7.1 %), and M. nonchromogenicum (7.1 %). NTM DNA was detected in 92 (76.7 %) samples. By qPCR analysis a statistically significant decrease (P < 0.01) was observed along the route from the reservoir (dam sediments), through water treatment sludge and finally to household sediments. The concentrations ranged from 10(0) to 10(4) DNA cells/g. It was confirmed that drinking water supply systems (watershed-reservoir-drinking water treatment plant-household) might be a potential transmission route for mycobacteria.
Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems.
Douterelo, I; Husband, S; Loza, V; Boxall, J
2016-07-15
The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. Copyright © 2016 Douterelo et al.
Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems
Husband, S.; Loza, V.; Boxall, J.
2016-01-01
ABSTRACT The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. IMPORTANCE This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers. PMID:27208119
The WRK Water Works is responsible for the abstraction and partial purifcation of surface water for the drinking water production of some 2m people in the Netherlands. Two water winning stations, one at a side canal of the Rhine, the other at IJsselmeer lake provide an annual tot...
Extensive localized or pitting corrosion of copper pipes used in household drinking-water plumbing can eventually lead to pinhole water leaks that may result in water damage, mold growth, and costly repairs. A large water system in Florida has been addressing a widespread pinhole...
Rusakovica, Julija; Kremer, Valentin D; Plötz, Thomas; Rohlf, Paige; Kyriazakis, Ilias
2017-09-29
There is increasing interest in the definition, measurement and use of traits associated with water use and drinking behaviour, mainly because water is a finite resource and its intake is an important part of animal health and well-being. Analysis of such traits has received little attention, due in part to the lack of appropriate technology to measure drinking behaviour. We exploited novel equipment to collect water intake data in two lines of turkey (A: 27,415 and B: 12,956 birds). The equipment allowed continuous recording of individual visits to the water station in a group environment. Our aim was to identify drinking behaviour traits of biological relevance, to estimate their genetic parameters and their genetic relationships with performance traits, and to identify drinking behaviour strategies among individuals. Visits to the drinkers were clustered into bouts, i.e. time intervals spent in drinking-related activity. Based on this, biologically relevant traits were defined: (1) number of visits per bout, (2) water intake per bout, (3) drinking time per bout, (4) drinking rate, (5) daily bout frequency, (6) daily bout duration, (7) daily drinking time and (8) daily water intake. Heritability estimates for most drinking behaviour traits were moderate to high and the most highly heritable traits were drinking rate (0.49 and 0.50) and daily drinking time (0.35 and 0.46 in lines A and B, respectively). Genetic correlations between drinking behaviour and performance traits were low except for moderate correlations between daily water intake and weight gain (0.46 and 0.47 in lines A and B, respectively). High estimates of breeding values for weight gain were found across the whole range of estimated breeding values for daily water intake, daily drinking time and water intake per bout. We show for the first time that drinking behaviour traits are moderately to highly heritable. Low genetic and phenotypic correlations with performance traits suggest that current breeding goals have not and will not affect normal water drinking behaviour. Birds express a wide range of different drinking behaviour strategies, which can be suitable to a wide range of environments and production systems.
Molecular diversity of drinking water bacterial communities using 16S rRNA gene sequence analyses
Our understanding of the microbial community structure of drinking water distribution system has relied on culture-based methods. However, recent studies have suggested that the majority of bacteria inhabiting distribution systems are unable to grow on artificial media. The goal ...
We report the draft genome sequences of six Mycobacterium immunogenum isolated from a chloraminated drinking water distribution system simulator subjected to changes in operational parameters. M. immunogenum, a rapidly growing mycobacteria previously reported as the cause of hyp...
A Decision Support System for Drinking Water Production Integrating Health Risks Assessment
Delpla, Ianis; Monteith, Donald T.; Freeman, Chris; Haftka, Joris; Hermens, Joop; Jones, Timothy G.; Baurès, Estelle; Jung, Aude-Valérie; Thomas, Olivier
2014-01-01
The issue of drinking water quality compliance in small and medium scale water services is of paramount importance in relation to the 98/83/CE European Drinking Water Directive (DWD). Additionally, concerns are being expressed over the implementation of the DWD with respect to possible impacts on water quality from forecast changes in European climate with global warming and further anticipated reductions in north European acid emissions. Consequently, we have developed a decision support system (DSS) named ARTEM-WQ (AwaReness Tool for the Evaluation and Mitigation of drinking Water Quality issues resulting from environmental changes) to support decision making by small and medium plant operators and other water stakeholders. ARTEM-WQ is based on a sequential risk analysis approach that includes consideration of catchment characteristics, climatic conditions and treatment operations. It provides a holistic evaluation of the water system, while also assessing human health risks of organic contaminants potentially present in treated waters (steroids, pharmaceuticals, pesticides, bisphenol-a, polychlorobiphenyls, polycyclic aromatic hydrocarbons, petrochemical hydrocarbons and disinfection by-products; n = 109). Moreover, the system provides recommendations for improvement while supporting decision making in its widest context. The tool has been tested on various European catchments and shows a promising potential to inform water managers of risks and appropriate mitigative actions. Further improvements should include toxicological knowledge advancement, environmental background pollutant concentrations and the assessment of the impact of distribution systems on water quality variation. PMID:25046634
U. S. drinking-water regulations: Treatment technologies and cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lykins, B.W. Jr.; Clark, R.M.
The Safe Drinking Water Act and its Amendments have imposed a large number of new regulations on the US drinking-water industry. A major set of regulations currently under consideration will control disinfectants and disinfection by-products. Included in the development of these regulations is an Information Collection Rule and an Enhanced Surface Water Treatment Rule. These rules will require monitoring for microorganisms such as Giardia, Cryptosporidium, and viruses. Certain surface-water systems may be required to remove microbiological contaminants above levels currently required by the Surface Water Treatment Rule. Also included in these rules will be monitoring requirements for disinfection by-products andmore » evaluation of precursor removal technologies. As various regulations are promulgated, regulators and those associated with the drinking-water industry need to be cognizant of the potential impact of treatment to control one contaminant or group of contaminants on control of other contaminants. Compliance with drinking-water regulations mandated under the Safe Drinking Water Act and its amendments has been estimated to cost about $1.6 billion.« less
Social disparities in nitrate-contaminated drinking water in California's San Joaquin Valley.
Balazs, Carolina; Morello-Frosch, Rachel; Hubbard, Alan; Ray, Isha
2011-09-01
Research on drinking water in the United States has rarely examined disproportionate exposures to contaminants faced by low-income and minority communities. This study analyzes the relationship between nitrate concentrations in community water systems (CWSs) and the racial/ethnic and socioeconomic characteristics of customers. We hypothesized that CWSs in California's San Joaquin Valley that serve a higher proportion of minority or residents of lower socioeconomic status have higher nitrate levels and that these disparities are greater among smaller drinking water systems. We used water quality monitoring data sets (1999-2001) to estimate nitrate levels in CWSs, and source location and census block group data to estimate customer demographics. Our linear regression model included 327 CWSs and reported robust standard errors clustered at the CWS level. Our adjusted model controlled for demographics and water system characteristics and stratified by CWS size. Percent Latino was associated with a 0.04-mg nitrate-ion (NO3)/L increase in a CWS's estimated NO3 concentration [95% confidence interval (CI), -0.08 to 0.16], and rate of home ownership was associated with a 0.16-mg NO3/L decrease (95% CI, -0.32 to 0.002). Among smaller systems, the percentage of Latinos and of homeownership was associated with an estimated increase of 0.44 mg NO3/L (95% CI, 0.03-0.84) and a decrease of 0.15 mg NO3/L (95% CI, -0.64 to 0.33), respectively. Our findings suggest that in smaller water systems, CWSs serving larger percentages of Latinos and renters receive drinking water with higher nitrate levels. This suggests an environmental inequity in drinking water quality.
Social Disparities in Nitrate-Contaminated Drinking Water in California’s San Joaquin Valley
Morello-Frosch, Rachel; Hubbard, Alan; Ray, Isha
2011-01-01
Background: Research on drinking water in the United States has rarely examined disproportionate exposures to contaminants faced by low-income and minority communities. This study analyzes the relationship between nitrate concentrations in community water systems (CWSs) and the racial/ethnic and socioeconomic characteristics of customers. Objectives: We hypothesized that CWSs in California’s San Joaquin Valley that serve a higher proportion of minority or residents of lower socioeconomic status have higher nitrate levels and that these disparities are greater among smaller drinking water systems. Methods: We used water quality monitoring data sets (1999–2001) to estimate nitrate levels in CWSs, and source location and census block group data to estimate customer demographics. Our linear regression model included 327 CWSs and reported robust standard errors clustered at the CWS level. Our adjusted model controlled for demographics and water system characteristics and stratified by CWS size. Results: Percent Latino was associated with a 0.04-mg nitrate-ion (NO3)/L increase in a CWS’s estimated NO3 concentration [95% confidence interval (CI), –0.08 to 0.16], and rate of home ownership was associated with a 0.16-mg NO3/L decrease (95% CI, –0.32 to 0.002). Among smaller systems, the percentage of Latinos and of homeownership was associated with an estimated increase of 0.44 mg NO3/L (95% CI, 0.03–0.84) and a decrease of 0.15 mg NO3/L (95% CI, –0.64 to 0.33), respectively. Conclusions: Our findings suggest that in smaller water systems, CWSs serving larger percentages of Latinos and renters receive drinking water with higher nitrate levels. This suggests an environmental inequity in drinking water quality. PMID:21642046
Groundwater quality in the Rio Grande aquifer system, southwestern United States
Musgrove, MaryLynn; Bexfield, Laura M.
2017-12-07
Groundwater provides nearly 50 percent of the Nation’s drinking water. To help protect this vital resource, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Project assesses groundwater quality in aquifers that are important sources of drinking water (Burow and Belitz, 2014). The Rio Grande aquifer system constitutes one of the important areas being evaluated.
Groundwater quality in the Cambrian-Ordovician aquifer system, midwestern United States
Stackelberg, Paul E.
2017-12-07
Groundwater provides nearly 50 percent of the Nation’s drinking water. To help protect this vital resource, the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Project assesses groundwater quality in aquifers that are important sources of drinking water (Burow and Belitz, 2014). The Cambrian-Ordovician aquifer system constitutes one of the important areas being evaluated.
This document presents the results of completed work using existing geographic information system (GIS) data to map existing water and sewer infrastructure and homes without access to safe drinking water and basic sanitation on the Navajo Nation.
EPA's National Homeland Security Research Center (Office of Research and Development) and Water Protection Task Force (Office of Water) have jointly developed a draft analytical guide that may be used by laboratories to plan for and provide support to a drinking water utility...
An Introduction to EPA's Water Supply and Water Resources Research and Ways of Collaborations
"Drinking water quality at the consumer's tap is the center piece of U.S. drinking water regulations to protect people's health. Recently promulgated Stage II DBP rules are an example, which requires a system approach in a multi-barrier strategy for compliance and risk managemen...
Comammox in drinking water systems.
Wang, Yulin; Ma, Liping; Mao, Yanping; Jiang, Xiaotao; Xia, Yu; Yu, Ke; Li, Bing; Zhang, Tong
2017-06-01
The discovery of complete ammonia oxidizer (comammox) has fundamentally upended our perception of the global nitrogen cycle. Here, we reported four metagenome assembled genomes (MAGs) of comammox Nitrospira that were retrieved from metagenome datasets of tap water in Singapore (SG-bin1 and SG-bin2), Hainan province, China (HN-bin3) and Stanford, CA, USA (ST-bin4). Genes of phylogenetically distinct ammonia monooxygenase subunit A (amoA) and hydroxylamine dehydrogenase (hao) were identified in these four MAGs. Phylogenetic analysis based on ribosomal proteins, AmoA, hao and nitrite oxidoreductase (subunits nxrA and nxrB) sequences indicated their close relationships with published comammox Nitrospira. Canonical ammonia-oxidizing microbes (AOM) were also identified in the three tap water samples, ammonia-oxidizing bacteria (AOB) in Singapore's and Stanford's samples and ammonia-oxidizing archaea (AOA) in Hainan's sample. The comammox amoA-like sequences were also detected from some other drinking water systems, and even outnumbered the AOA and AOB amoA-like sequences. The findings of MAGs and the occurrences of AOM in different drinking water systems provided a significant clue that comammox are widely distributed in drinking water systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Levels of exposure from drinking water.
van Dijk-Looijaard, A M; van Genderen, J
2000-01-01
The relative exposure from drinking water is generally small, although there is a lack of information on total daily intake of individual organic micropollutants. There are, however, a few exceptions. Materials used in domestic distribution systems (lead, copper and plastics) may cause a deterioration of the water quality, especially in stagnant water. The relative exposure to the related compounds may increase considerably. Monitoring data from the tap (with defined sampling techniques) are needed. Also, disinfection/oxidation by-products (bromate, trihalomethanes) can be present in drinking water in considerable amounts and the relative exposure from drinking water may even approach 100%. Especially for volatile organic micropollutants, exposure routes from drinking water other than ingestion must be taken into account (inhalation, percutaneous uptake). When there is a need for detection of substances at very low levels it is important that the measurements are reliable. International interlaboratory comparisons for organic micropollutants are lacking at the moment.
Rodriguez-Alvarez, María S; Moraña, Liliana B; Salusso, María M; Seghezzo, Lucas
Drinking water monitoring plans are important to characterize both treated and untreated water used for drinking purposes. Access to drinking water increased in recent years as a response to the Millennium Development Goals set for 2015. The new Sustainable Development Goals aim to ensure universal access to safe drinking water by 2030. Within the framework of these global goals, it is crucial to monitor local drinking water systems. In this paper, treated and untreated water from different sources currently consumed in a specific town in Salta, northern Argentina, was thoroughly assessed. Monitoring extended along several seasons and included the physical, chemical and microbiological variables recommended by the Argentine Food Code. On the one hand, treated water mostly complies with these standards, with some non-compliances detected during the rainy season. Untreated water, on the other hand, never meets microbiological standards and is unfit for human consumption. Monitoring seems essential to detect anomalies and help guarantee a constant provision of safe drinking water. New treatment plants are urgently needed to expand the water grid to the entire population. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Clasen, T; Brown, J; Suntura, O; Collin, S
2004-01-01
A randomised controlled field trial was conducted to evaluate the effectiveness of ceramic drip filters to improve the microbiological quality of drinking water in a low-income community in rural Bolivia. In four rounds of water sampling over five months, 100% of the samples were free of thermotolerant (faecal) coliforms (TTC) compared to an arithmetic mean TTC count of 1517, 406, 167 and 245 among control households which continued to use their customary sources of drinking water. The filter systems produced water that consistently met WHO drinking-water standards despite levels of turbidity that presented a challenge to other low-cost POU treatment methods. The filter systems also demonstrated an ability to maintain the high quality of the treated water against subsequent re-contamination in the home.
Developing a national framework for safe drinking water--case study from Iceland.
Gunnarsdottir, Maria J; Gardarsson, Sigurdur M; Bartram, Jamie
2015-03-01
Safe drinking water is one of the fundaments of society and experience has shown that a holistic national framework is needed for its effective provision. A national framework should include legal requirements on water protection, surveillance on drinking water quality and performance of the water supply system, and systematic preventive management. Iceland has implemented these requirements into legislation. This case study analyzes the success and challenges encountered in implementing the legislation and provide recommendations on the main shortcomings identified through the Icelandic experience. The results of the analysis show that the national framework for safe drinking water is mostly in place in Iceland. The shortcomings include the need for both improved guidance and control by the central government; and for improved surveillance of the water supply system and implementation of the water safety plan by the Local Competent Authorities. Communication to the public and between stakeholders is also insufficient. There is also a deficiency in the national framework regarding small water supply systems that needs to be addressed. Other elements are largely in place or on track. Most of the lessons learned are transferable to other European countries where the legal system around water safety is built on a common foundation from EU directives. The lessons can also provide valuable insights into how to develop a national framework elsewhere. Copyright © 2014 Elsevier GmbH. All rights reserved.
Schaider, Laurel A; Rudel, Ruthann A; Ackerman, Janet M; Dunagan, Sarah C; Brody, Julia Green
2014-01-15
Approximately 40% of U.S. residents rely on groundwater as a source of drinking water. Groundwater, especially unconfined sand and gravel aquifers, is vulnerable to contamination from septic systems and infiltration of wastewater treatment plant effluent. In this study, we characterized concentrations of pharmaceuticals, perfluorosurfactants, and other organic wastewater compounds (OWCs) in the unconfined sand and gravel aquifer of Cape Cod, Massachusetts, USA, where septic systems are prevalent. Raw water samples from 20 public drinking water supply wells on Cape Cod were tested for 92 OWCs, as well as surrogates of wastewater impact. Fifteen of 20 wells contained at least one OWC; the two most frequently-detected chemicals were sulfamethoxazole (antibiotic) and perfluorooctane sulfonate (perfluorosurfactant). Maximum concentrations of sulfamethoxazole (113 ng/L) and the anticonvulsant phenytoin (66 ng/L) matched or exceeded maximum reported concentrations in other U.S. public drinking water sources. The sum of pharmaceutical concentrations and the number of detected chemicals were both significantly correlated with nitrate, boron, and extent of unsewered residential and commercial development within 500 m, indicating that wastewater surrogates can be useful for identifying wells most likely to contain OWCs. Septic systems appear to be the primary source of OWCs in Cape Cod groundwater, although wastewater treatment plants and other sources were potential contributors to several wells. These results show that drinking water supplies in unconfined aquifers where septic systems are prevalent may be among the most vulnerable to OWCs. The presence of mixtures of OWCs in drinking water raises human health concerns; a full evaluation of potential risks is limited by a lack of health-based guidelines and toxicity assessments. © 2013. Published by Elsevier B.V. All rights reserved.
Potgieter, Sarah; Pinto, Ameet; Sigudu, Makhosazana; du Preez, Hein; Ncube, Esper; Venter, Stephanus
2018-08-01
Long-term spatial-temporal investigations of microbial dynamics in full-scale drinking water distribution systems are scarce. These investigations can reveal the process, infrastructure, and environmental factors that influence the microbial community, offering opportunities to re-think microbial management in drinking water systems. Often, these insights are missed or are unreliable in short-term studies, which are impacted by stochastic variabilities inherent to large full-scale systems. In this two-year study, we investigated the spatial and temporal dynamics of the microbial community in a large, full scale South African drinking water distribution system that uses three successive disinfection strategies (i.e. chlorination, chloramination and hypochlorination). Monthly bulk water samples were collected from the outlet of the treatment plant and from 17 points in the distribution system spanning nearly 150 km and the bacterial community composition was characterised by Illumina MiSeq sequencing of the V4 hypervariable region of the 16S rRNA gene. Like previous studies, Alpha- and Betaproteobacteria dominated the drinking water bacterial communities, with an increase in Betaproteobacteria post-chloramination. In contrast with previous reports, the observed richness, diversity, and evenness of the bacterial communities were higher in the winter months as opposed to the summer months in this study. In addition to temperature effects, the seasonal variations were also likely to be influenced by changes in average water age in the distribution system and corresponding changes in disinfectant residual concentrations. Spatial dynamics of the bacterial communities indicated distance decay, with bacterial communities becoming increasingly dissimilar with increasing distance between sampling locations. These spatial effects dampened the temporal changes in the bulk water community and were the dominant factor when considering the entire distribution system. However, temporal variations were consistently stronger as compared to spatial changes at individual sampling locations and demonstrated seasonality. This study emphasises the need for long-term studies to comprehensively understand the temporal patterns that would otherwise be missed in short-term investigations. Furthermore, systematic long-term investigations are particularly critical towards determining the impact of changes in source water quality, environmental conditions, and process operations on the changes in microbial community composition in the drinking water distribution system. Copyright © 2018 Elsevier Ltd. All rights reserved.
Factors Affecting Atrazine Concentration and Quantitative Determination in Chlorinated Water
Although the herbicide atrazine has been reported to not react measurably with free chlorine during drinking water treatment, this work demonstrates that at contact times consistent with drinking water distribution system residence times, a transformation of atrazine can be obser...
REGULATIONS ON THE DISPOSAL OF ARSENIC RESIDUALS FROM DRINKING WATER TREATMENT PLANTS
This report summarizes federal and selected state regulations that govern the management of residuals produced by small water treatment systems removing arsenic from drinking water. The document focuses on the residuals produced by five treatment processes: anion exchange, activa...
USDA-ARS?s Scientific Manuscript database
Background: Current United States drinking water regulations create areas with different levels of water quality. Municipalities accessing untreated groundwater and households with unmonitored private wells may be at increased risk for acquiring waterborne disease. Objectives: The study investigat...
The Next Generation of Disinfection By-Products
The disinfection of drinking water has been rightly hailed as a public health triumph of the 20th century. Millions of people worldwide receive quality drinking water every day from their public water systems. However, chemical disinfection has also produced an unintended health ...
REMOTE MONITORING OF WATER QUALITY IN DRINKING WATER DISTRIBUTION SYSTEMS
Water is a precious natural resource that Americans enjoy with little thought to contamination or potential tampering. However, the terrorist attacks on September 11, 2001, and ensuing threats have increased awareness of the potential for contamination of the nation's drinking w...
US EPA/ORD Condition Assessment Research for Drinking Water Conveyance Infrastructure
This presentation describes research on condition assessment for drinking water transmission and distribution systems that EPA is conducting under the U.S. Environmental Protection Agency’s Aging Water Infrastructure (AWI) Research Program. This research program will help U.S. ...
The challenges facing small drinking water systems were a major focus of the 1996 Amendments to the Safe Drinking Water Act (SDWA). One way Congress sought to help systems meet these challenges was by explicitly allowing systems to install point-of-use (POU) and point-of-entry (P...
White, Colin; Tancos, Matthew; Lytle, Darren A.
2011-01-01
A corroded lead service line was removed from a drinking water distribution system, and the microbial community was profiled using 16S rRNA gene techniques. This is the first report of the characterization of a biofilm on the surface of a corroded lead drinking water service line. The majority of phylotypes have been linked to heavy-metal-contaminated environments. PMID:21652741
Strontium concentrations in corrosion products from residential drinking water distribution systems.
Gerke, Tammie L; Little, Brenda J; Luxton, Todd P; Scheckel, Kirk G; Maynard, J Barry
2013-05-21
The United States Environmental Protection Agency (US EPA) will require some U.S. drinking water distribution systems (DWDS) to monitor nonradioactive strontium (Sr(2+)) in drinking water in 2013. Iron corrosion products from four DWDS were examined to assess the potential for Sr(2+) binding and release. Average Sr(2+) concentrations in the outermost layer of the corrosion products ranged from 3 to 54 mg kg(-1) and the Sr(2+) drinking water concentrations were all ≤0.3 mg L(-1). Micro-X-ray adsorption near edge structure spectroscopy and linear combination fitting determined that Sr(2+) was principally associated with CaCO3. Sr(2+) was also detected as a surface complex associated with α-FeOOH. Iron particulates deposited on a filter inside a home had an average Sr(2+) concentration of 40.3 mg kg(-1) and the associated drinking water at a tap was 210 μg L(-1). The data suggest that elevated Sr(2+) concentrations may be associated with iron corrosion products that, if disturbed, could increase Sr(2+) concentrations above the 0.3 μg L(-1) US EPA reporting threshold. Disassociation of very small particulates could result in drinking water Sr(2+) concentrations that exceed the US EPA health reference limit (4.20 mg kg(-1) body weight).
Fate of Salmonella Typhimurium in laboratory-scale drinking water biofilms.
Schaefer, L M; Brözel, V S; Venter, S N
2013-12-01
Investigations were carried out to evaluate and quantify colonization of laboratory-scale drinking water biofilms by a chromosomally green fluorescent protein (gfp)-tagged strain of Salmonella Typhimurium. Gfp encodes the green fluorescent protein and thus allows in situ detection of undisturbed cells and is ideally suited for monitoring Salmonella in biofilms. The fate and persistence of non-typhoidal Salmonella in simulated drinking water biofilms was investigated. The ability of Salmonella to form biofilms in monoculture and the fate and persistence of Salmonella in a mixed aquatic biofilm was examined. In monoculture S. Typhimurium formed loosely structured biofilms. Salmonella colonized established multi-species drinking water biofilms within 24 hours, forming micro-colonies within the biofilm. S. Typhimurium was also released at high levels from the drinking water-associated biofilm into the water passing through the system. This indicated that Salmonella could enter into, survive and grow within, and be released from a drinking water biofilm. The ability of Salmonella to survive and persist in a drinking water biofilm, and be released at high levels into the flow for recolonization elsewhere, indicates the potential for a persistent health risk to consumers once a network becomes contaminated with this bacterium.
The use of nutshell carbons in drinking water filters for removal of trace metals.
Ahmedna, Mohamed; Marshall, Wayne E; Husseiny, Abdo A; Rao, Ramu M; Goktepe, Ipek
2004-02-01
Filtration of drinking water by point-of-use (POU) or point-of-entry (POE) systems is becoming increasingly popular in the United States. Drinking water is filtered to remove both organic and inorganic contaminants. The objective of this study was to evaluate the use of granular activated carbon from nutshells (almond, English walnut, pecan) in a POU water filtration system to determine its effectiveness in removing select, potentially toxic metal ions, namely, copper (Cu2+), lead (Pb2+) or zinc (Zn2+) found in drinking water. The nutshell-based carbon system was designated "Envirofilter" and was compared to four commercial POU systems with brand names of BRITA, Omni Filter, PUR and Teledyne Water Pik. Eight prototype "Envirofilters", consisting of individual or binary mixtures of carbons made from acid-activated almond or pecan shells and steam-activated pecan or walnut shells were constructed and evaluated for adsorption of the three metal ions. The results indicated that a binary mixture of carbons from acid-activated almond and either steam-activated pecan or walnut shells were the most effective in removing these metals from drinking water of all the POU systems evaluated. Binary mixtures of acid-activated almond shell-based carbon with either steam-activated pecan shell- or walnut shell-based carbon removed nearly 100% of lead ion, 90-95% of copper ion and 80-90% of zinc ion. Overall the performance data on the "Envirofilters" suggest that these prototypes require less carbon than commercial filters to achieve the same metal adsorption efficiency and may also be a less expensive product.
ENVIRONMENTAL TECHNOLOGY VERIFICATION EVALUATIONS OF ARSENIC REDUCTION SYSTEMS FOR DRINKING WATER
Arsenic in drinking water is a known carcinogen with additional adverse human health impacts. For the 4,100 affected systems, 37 to 55 cancer cases per year are estimated, with about half projected to result in deaths if treatment solutions are not implemented. The Environmenta...
Trends in Nitrate Drinking Water Violations Across the US ...
Background/Question/Methods Safe drinking water is essential for the health and well-being of humans and life on Earth. Previous studies have shown that groundwater and other sources of drinking water can be contaminated with nitrate above the 10 mg nitrate-N L-1 maximum contaminant level (MCL), which is known to have adverse health effects, including certain cancers. Public water systems (PWS) across the US have been required since 1979 to report violations of the nitrate MCL to the US Environmental Protection Agency’s Safe Drinking Water Information System (SDWIS). The objective of this research was to use SDWIS data to assess temporal and spatial trends for nitrate violations. We collected data from SDWIS on the number of PWS that violated the nitrate MCL at least once each year. The proportion of systems in violation each year was calculated by diving the number of systems in violation by the total number of active systems that year. The number of people served by systems in violation was calculated by summing the number of people served by each PWS in violation. Results/Conclusions We found that the number and proportion of systems in violation for nitrate significantly increased over time, almost doubling from 280 (0.16%) to 527 (0.33%) systems between 1994 and 2010. The increase in number and proportion of systems in violation is attributed to an increase in violations for groundwater systems, whereas violations for surface water systems have
Li, Ting; Yu, Dian; Xian, Qiming; Li, Aimin; Sun, Cheng
2015-08-01
We surveyed the occurrence of nine N-nitrosamine species in ten bottled drinking waters from supermarket and other water samples including raw waters, finished waters, and distribution system waters from nine municipal drinking water treatment plants in eight cities of Jiangsu Province, East China. N-nitrosodimethylamine (NDMA) was detected in one of ten bottled drinking water samples at concentration of 4.8 ng/L and N-nitrosomorpholine (NMor) was detected in four of the ten bottles with an average concentration and a standard deviation of 16 ± 15 ng/L. The levels of nitrosamines in the distribution system water samples collected during summer season ranged from below detection limit (BDL) to 5.4 ng/L for NDMA, BDL to 9.5 ng/L for N-nitrosomethylethylamine (NMEA), BDL to 2.7 ng/L for N-nitrosodiethylamine (NDEA) and BDL to 8.5 ng/L for N-nitrosopyrrolidine (NPyr). Samples of distribution system waters collected in winter season had levels of nitrosamines ranged from BDL to 45 ng/L for NDMA, BDL to 5.2 ng/L for NPyr, and BDL to 309 ng/L for N-nitrosopiperidine (NPip). A positive correlation of the concentration of NDMA as well as the total nine N-nitrosamines between finished waters and distribution system waters was observed. Both dissolved organic carbon and nitrite were found to correlate linearly with N-nitrosamine levels in raw waters.
Jain, Meha; Lim, Yili; Arce-Nazario, Javier A; Uriarte, María
2014-01-01
Identifying which factors influence household water management can help policy makers target interventions to improve drinking water quality for communities that may not receive adequate water quality at the tap. We assessed which perceptional and socio-demographic factors are associated with household drinking water management strategies in rural Puerto Rico. Specifically, we examined which factors were associated with household decisions to boil or filter tap water before drinking, or to obtain drinking water from multiple sources. We find that households differ in their management strategies depending on the institution that distributes water (i.e. government PRASA vs community-managed non-PRASA), perceptions of institutional efficacy, and perceptions of water quality. Specifically, households in PRASA communities are more likely to boil and filter their tap water due to perceptions of low water quality. Households in non-PRASA communities are more likely to procure water from multiple sources due to perceptions of institutional inefficacy. Based on informal discussions with community members, we suggest that water quality may be improved if PRASA systems improve the taste and odor of tap water, possibly by allowing for dechlorination prior to distribution, and if non-PRASA systems reduce the turbidity of water at the tap, possibly by increasing the degree of chlorination and filtering prior to distribution. Future studies should examine objective water quality standards to identify whether current management strategies are effective at improving water quality prior to consumption.
Jain, Meha; Lim, Yili; Arce-Nazario, Javier A.; Uriarte, María
2014-01-01
Identifying which factors influence household water management can help policy makers target interventions to improve drinking water quality for communities that may not receive adequate water quality at the tap. We assessed which perceptional and socio-demographic factors are associated with household drinking water management strategies in rural Puerto Rico. Specifically, we examined which factors were associated with household decisions to boil or filter tap water before drinking, or to obtain drinking water from multiple sources. We find that households differ in their management strategies depending on the institution that distributes water (i.e. government PRASA vs community-managed non-PRASA), perceptions of institutional efficacy, and perceptions of water quality. Specifically, households in PRASA communities are more likely to boil and filter their tap water due to perceptions of low water quality. Households in non-PRASA communities are more likely to procure water from multiple sources due to perceptions of institutional inefficacy. Based on informal discussions with community members, we suggest that water quality may be improved if PRASA systems improve the taste and odor of tap water, possibly by allowing for dechlorination prior to distribution, and if non-PRASA systems reduce the turbidity of water at the tap, possibly by increasing the degree of chlorination and filtering prior to distribution. Future studies should examine objective water quality standards to identify whether current management strategies are effective at improving water quality prior to consumption. PMID:24586302
Bereskie, Ty; Haider, Husnain; Rodriguez, Manuel J; Sadiq, Rehan
2017-08-23
Traditional approaches for benchmarking drinking water systems are binary, based solely on the compliance and/or non-compliance of one or more water quality performance indicators against defined regulatory guidelines/standards. The consequence of water quality failure is dependent on location within a water supply system as well as time of the year (i.e., season) with varying levels of water consumption. Conventional approaches used for water quality comparison purposes fail to incorporate spatiotemporal variability and degrees of compliance and/or non-compliance. This can lead to misleading or inaccurate performance assessment data used in the performance benchmarking process. In this research, a hierarchical risk-based water quality performance benchmarking framework is proposed to evaluate small drinking water systems (SDWSs) through cross-comparison amongst similar systems. The proposed framework (R WQI framework) is designed to quantify consequence associated with seasonal and location-specific water quality issues in a given drinking water supply system to facilitate more efficient decision-making for SDWSs striving for continuous performance improvement. Fuzzy rule-based modelling is used to address imprecision associated with measuring performance based on singular water quality guidelines/standards and the uncertainties present in SDWS operations and monitoring. This proposed R WQI framework has been demonstrated using data collected from 16 SDWSs in Newfoundland and Labrador and Quebec, Canada, and compared to the Canadian Council of Ministers of the Environment WQI, a traditional, guidelines/standard-based approach. The study found that the R WQI framework provides an in-depth state of water quality and benchmarks SDWSs more rationally based on the frequency of occurrence and consequence of failure events.
Chowdhury, Shakhawat; Champagne, Pascale; McLellan, P James
2009-07-01
Disinfection for the supply of safe drinking water forms a variety of known and unknown byproducts through reactions between the disinfectants and natural organic matter. Chronic exposure to disinfection byproducts through the ingestion of drinking water, inhalation and dermal contact during regular indoor activities (e.g., showering, bathing, cooking) may pose cancer and non-cancer risks to human health. Since their discovery in drinking water in 1974, numerous studies have presented models to predict DBP formation in drinking water. To date, more than 48 scientific publications have reported 118 models to predict DBP formation in drinking waters. These models were developed through laboratory and field-scale experiments using raw, pretreated and synthetic waters. This paper aims to review DBP predictive models, analyze the model variables, assess the model advantages and limitations, and to determine their applicability to different water supply systems. The paper identifies the current challenges and future research needs to better control DBP formation. Finally, important directions for future research are recommended to protect human health and to follow the best management practices.
Brown, Brandon; Wachowiak-Smolíková, Renata; Spence, Nicholas D.; Wachowiak, Mark P.; Walters, Dan F.
2016-01-01
Securing safe and adequate drinking water is an ongoing issue for many Canadian First Nations communities despite nearly 15 years of reports, studies, policy changes, financial commitments, and regulations. The federal drinking water evaluation scheme is narrowly scoped, ignoring community level social factors, which may play a role in access to safe water in First Nations. This research used the 2006 Aboriginal Affairs and Northern Development Canada First Nations Drinking Water System Risk Survey data and the Community Well-Being Index, including labour force, education, housing, and income, from the 2006 Census. Bivariate analysis was conducted using the Spearman’s correlation, Kendall’s tau correlation, and Pearson’s correlation. Multivariable analysis was conducted using an ordinal (proportional or cumulative odds) regression model. Results showed that the regression model was significant. Community socioeconomic indicators had no relationship with drinking water risk characterization in both the bivariate and multivariable models, with the sole exception of labour force, which had a significantly positive effect on drinking water risk rankings. Socioeconomic factors were not important in explaining access to safe drinking water in First Nations communities. Improvements in the quality of safe water data as well as an examination of other community processes are required to address this pressing policy issue. PMID:27157172
Brown, Brandon; Wachowiak-Smolíková, Renata; Spence, Nicholas D; Wachowiak, Mark P; Walters, Dan F
2016-09-01
Securing safe and adequate drinking water is an ongoing issue for many Canadian First Nations communities despite nearly 15 years of reports, studies, policy changes, financial commitments, and regulations. The federal drinking water evaluation scheme is narrowly scoped, ignoring community level social factors, which may play a role in access to safe water in First Nations. This research used the 2006 Aboriginal Affairs and Northern Development Canada First Nations Drinking Water System Risk Survey data and the Community Well-Being Index, including labour force, education, housing, and income, from the 2006 Census. Bivariate analysis was conducted using the Spearman's correlation, Kendall's tau correlation, and Pearson's correlation. Multivariable analysis was conducted using an ordinal (proportional or cumulative odds) regression model. Results showed that the regression model was significant. Community socioeconomic indicators had no relationship with drinking water risk characterization in both the bivariate and multivariable models, with the sole exception of labour force, which had a significantly positive effect on drinking water risk rankings. Socioeconomic factors were not important in explaining access to safe drinking water in First Nations communities. Improvements in the quality of safe water data as well as an examination of other community processes are required to address this pressing policy issue.
Schulte, J G; Vicory, A H
2005-01-01
Source water quality is of major concern to all drinking water utilities. The accidental introduction of contaminants to their source water is a constant threat to utilities withdrawing water from navigable or industrialized rivers. The events of 11 September, 2001 in the United States have heightened concern for drinking water utility security as their source water and finished water may be targets for terrorist acts. Efforts are underway in several parts of the United States to strengthen early warning capabilities. This paper will focus on those efforts in the Ohio River Valley Basin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klise, Katherine A.; Hart, David; Moriarty, Dylan Michael
Drinking water systems face multiple challenges, including aging infrastructure, water quality concerns, uncertainty in supply and demand, natural disasters, environmental emergencies, and cyber and terrorist attacks. All of these have the potential to disrupt a large portion of a water system causing damage to infrastructure and outages to customers. Increasing resilience to these types of hazards is essential to improving water security. As one of the United States (US) sixteen critical infrastructure sectors, drinking water is a national priority. The National Infrastructure Advisory Council defined infrastructure resilience as “the ability to reduce the magnitude and/or duration of disruptive events. Themore » effectiveness of a resilient infrastructure or enterprise depends upon its ability to anticipate, absorb, adapt to, and/or rapidly recover from a potentially disruptive event”. Being able to predict how drinking water systems will perform during disruptive incidents and understanding how to best absorb, recover from, and more successfully adapt to such incidents can help enhance resilience.« less
Evaluation of methods for the extraction of DNA from drinking water distribution system biofilms.
Hwang, Chiachi; Ling, Fangqiong; Andersen, Gary L; LeChevallier, Mark W; Liu, Wen-Tso
2012-01-01
While drinking water biofilms have been characterized in various drinking water distribution systems (DWDS), little is known about the impact of different DNA extraction methods on the subsequent analysis of microbial communities in drinking water biofilms. Since different DNA extraction methods have been shown to affect the outcome of microbial community analysis in other environments, it is necessary to select a DNA extraction method prior to the application of molecular tools to characterize the complex microbial ecology of the DWDS. This study compared the quantity and quality of DNA yields from selected DWDS bacteria with different cell wall properties using five widely used DNA extraction methods. These were further selected and evaluated for their efficiency and reproducibility of DNA extraction from DWDS samples. Terminal restriction fragment length analysis and the 454 pyrosequencing technique were used to interpret the differences in microbial community structure and composition, respectively, from extracted DNA. Such assessments serve as a concrete step towards the determination of an optimal DNA extraction method for drinking water biofilms, which can then provide a reliable comparison of the meta-analysis results obtained in different laboratories.
THE FORMATION OF PB(IV) OXIDES IN CHLORINATED WATER
Recent research has shown that Pb(IV) oxides can play an important geochemical role in drinking water distribution systems. The basis of most guidance for lead control in drinking water, however, presumes that Pb(II) solids control lead solubility. Therefore, it is important that...
Importance of regular testing of private drinking water systems in North Carolina.
Barros, Nirmalla; Rudo, Kenneth; Shehee, Mina
2014-01-01
North Carolina state laws require that water from newly constructed private wells be tested for chemical and microbiologic contamination, but existing wells are not routinely tested. This commentary highlights the importance of regular testing of all private sources of drinking water.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Administrator of the Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j... water below the ground surface in a zone of saturation. (r) Underground source of drinking water means... system; and (A) Currently supplies drinking water for human consumption; or (B) Contains fewer than 10...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Administrator of the Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j... water below the ground surface in a zone of saturation. (r) Underground source of drinking water means... system; and (A) Currently supplies drinking water for human consumption; or (B) Contains fewer than 10...
This presentation provides a review of numerous drinking water and geochemical investigations and recent studies of pipe deposits and water treatment materials. This analysis shows that there is growing evidence that many regulated drinking water constituents are not conservativ...
EVALUATION OF DRINKING WATER TREATMENT TECHNIQUES FOR EDC REMOVAL
Many of the chemicals identified as potential endocrine disrupting chemicals (EDCs) may be present in surface or ground waters used as drinking water sources, due to their disposal via domestic and industrial sewage treatment systems and wet-weather runoff. In order to decrease t...
Comparison of culture and qPCR methods in detection of mycobacteria from drinking waters.
Räsänen, Noora H J; Rintala, Helena; Miettinen, Ilkka T; Torvinen, Eila
2013-04-01
Environmental mycobacteria are common bacteria in man-made water systems and may cause infections and hypersensitivity pneumonitis via exposure to water. We compared a generally used cultivation method and a quantitative polymerase chain reaction (qPCR) method to detect mycobacteria in 3 types of drinking waters: surface water, ozone-treated surface water, and groundwater. There was a correlation between the numbers of mycobacteria obtained by cultivation and qPCR methods, but the ratio of the counts obtained by the 2 methods varied among the types of water. The qPCR counts in the drinking waters produced from surface or groundwater were 5 to 34 times higher than culturable counts. In ozone-treated surface waters, both methods gave similar counts. The ozone-treated drinking waters had the highest concentration of assimilable organic carbon, which may explain the good culturability. In warm tap waters, qPCR gave 43 times higher counts than cultivation, but both qPCR counts and culturable counts were lower than those in the drinking waters collected from the same sites. The TaqMan qPCR method is a rapid and sensitive tool for total quantitation of mycobacteria in different types of clean waters. The raw water source and treatments affect both culturability and total numbers of mycobacteria in drinking waters.
Kato, Masashi; Kumasaka, Mayuko Y; Ohnuma, Shoko; Furuta, Akio; Kato, Yoko; Shekhar, Hossain U; Kojima, Michiyo; Koike, Yasuko; Dinh Thang, Nguyen; Ohgami, Nobutaka; Ly, Thuy Bich; Jia, Xiaofang; Yetti, Husna; Naito, Hisao; Ichihara, Gaku; Yajima, Ichiro
2013-01-01
Health risk for well drinking water is a worldwide problem. Our recent studies showed increased toxicity by exposure to barium alone (≤700 µg/L) and coexposure to barium (137 µg/L) and arsenic (225 µg/L). The present edition of WHO health-based guidelines for drinking water revised in 2011 has maintained the values of arsenic (10 µg/L) and barium (700 µg/L), but not elements such as manganese, iron and zinc. Nevertheless, there have been very few studies on barium in drinking water and human samples. This study showed significant correlations between levels of arsenic and barium, but not its homologous elements (magnesium, calcium and strontium), in urine, toenail and hair samples obtained from residents of Jessore, Bangladesh. Significant correlation between levels of arsenic and barium in well drinking water and levels in human urine, toenail and hair samples were also observed. Based on these results, a high-performance and low-cost adsorbent composed of a hydrotalcite-like compound for barium and arsenic was developed. The adsorbent reduced levels of barium and arsenic from well water in Bangladesh and Vietnam to <7 µg/L within 1 min. Thus, we have showed levels of arsenic and barium in humans and propose a novel remediation system.
Kato, Masashi; Kumasaka, Mayuko Y.; Ohnuma, Shoko; Furuta, Akio; Kato, Yoko; Shekhar, Hossain U.; Kojima, Michiyo; Koike, Yasuko; Dinh Thang, Nguyen; Ohgami, Nobutaka; Ly, Thuy Bich; Jia, Xiaofang; Yetti, Husna; Naito, Hisao; Ichihara, Gaku; Yajima, Ichiro
2013-01-01
Health risk for well drinking water is a worldwide problem. Our recent studies showed increased toxicity by exposure to barium alone (≤700 µg/L) and coexposure to barium (137 µg/L) and arsenic (225 µg/L). The present edition of WHO health-based guidelines for drinking water revised in 2011 has maintained the values of arsenic (10 µg/L) and barium (700 µg/L), but not elements such as manganese, iron and zinc. Nevertheless, there have been very few studies on barium in drinking water and human samples. This study showed significant correlations between levels of arsenic and barium, but not its homologous elements (magnesium, calcium and strontium), in urine, toenail and hair samples obtained from residents of Jessore, Bangladesh. Significant correlation between levels of arsenic and barium in well drinking water and levels in human urine, toenail and hair samples were also observed. Based on these results, a high-performance and low-cost adsorbent composed of a hydrotalcite-like compound for barium and arsenic was developed. The adsorbent reduced levels of barium and arsenic from well water in Bangladesh and Vietnam to <7 µg/L within 1 min. Thus, we have showed levels of arsenic and barium in humans and propose a novel remediation system. PMID:23805262
Leaching of Heavy Metals from Water Bottle Components into the Drinking Water of Rodents
Nunamaker, Elizabeth A; Otto, Kevin J; Artwohl, James E; Fortman, Jeffrey D
2013-01-01
Providing high-quality, uncontaminated drinking water is an essential component of rodent husbandry. Acidification of drinking water is a common technique to control microbial growth but is not a benign treatment. In addition to its potential biologic effects, acidified water might interact with the water-delivery system, leading to the leaching of heavy metals into the drinking water. The goal of the current study was to evaluate the effects of water acidification and autoclaving on water-bottle assemblies. The individual components of the system (stainless-steel sipper tubes, rubber stoppers, neoprene stoppers, and polysulfone water bottles) were acid-digested and analyzed for cadmium, chromium, copper, iron, lead, magnesium, manganese, selenium, and zinc to quantify the metal composition of each material. In addition the amounts of these metals that leached into tap and acidified water with and without autoclaving were quantified after 1 wk of contact time. On a weight basis, sipper tubes contained the largest quantities of all metals except magnesium and zinc, which were greatest in the neoprene stoppers. Except for cadmium and selenium, all metals had leached into the water after 1 wk, especially under the acidified condition. The quantities of copper, lead, and zinc that leached into the drinking water were the most noteworthy, because the resulting concentrations had the potential to confound animal experiments. On the basis of these findings, we suggest that water-quality monitoring programs include heavy metal analysis at the level of water delivery to animals. PMID:23562029
Leaching of heavy metals from water bottle components into the drinking water of rodents.
Nunamaker, Elizabeth A; Otto, Kevin J; Artwohl, James E; Fortman, Jeffrey D
2013-01-01
Providing high-quality, uncontaminated drinking water is an essential component of rodent husbandry. Acidification of drinking water is a common technique to control microbial growth but is not a benign treatment. In addition to its potential biologic effects, acidified water might interact with the water-delivery system, leading to the leaching of heavy metals into the drinking water. The goal of the current study was to evaluate the effects of water acidification and autoclaving on water-bottle assemblies. The individual components of the system (stainless-steel sipper tubes, rubber stoppers, neoprene stoppers, and polysulfone water bottles) were acid-digested and analyzed for cadmium, chromium, copper, iron, lead, magnesium, manganese, selenium, and zinc to quantify the metal composition of each material. In addition the amounts of these metals that leached into tap and acidified water with and without autoclaving were quantified after 1 wk of contact time. On a weight basis, sipper tubes contained the largest quantities of all metals except magnesium and zinc, which were greatest in the neoprene stoppers. Except for cadmium and selenium, all metals had leached into the water after 1 wk, especially under the acidified condition. The quantities of copper, lead, and zinc that leached into the drinking water were the most noteworthy, because the resulting concentrations had the potential to confound animal experiments. On the basis of these findings, we suggest that water-quality monitoring programs include heavy metal analysis at the level of water delivery to animals.
NASA Astrophysics Data System (ADS)
Ivanova, V.; Surleva, A.; Koleva, B.
2018-06-01
An ion chromatographic method for determination of fluoride, chloride, nitrate and sulphate in untreated and treated drinking waters was described. An automated 850 IC Professional, Metrohm system equipped with conductivity detector and Metrosep A Supp 7-250 (250 x 4 mm) column was used. The validation of the method was performed for simultaneous determination of all studied analytes and the results have showed that the validated method fits the requirements of the current water legislation. The main analytical characteristics were estimated for each of studied analytes: limits of detection, limits of quantification, working and linear ranges, repeatability and intermediate precision, recovery. The trueness of the method was estimated by analysis of certified reference material for soft drinking water. Recovery test was performed on spiked drinking water samples. An uncertainty was estimated. The method was applied for analysis of drinking waters before and after chlorination.
Evaluating the risk of water distribution system failure: A shared frailty model
NASA Astrophysics Data System (ADS)
Clark, Robert M.; Thurnau, Robert C.
2011-12-01
Condition assessment (CA) Modeling is drawing increasing interest as a technique that can assist in managing drinking water infrastructure. This paper develops a model based on the application of a Cox proportional hazard (PH)/shared frailty model and applies it to evaluating the risk of failure in drinking water networks using data from the Laramie Water Utility (located in Laramie, Wyoming, USA). Using the risk model a cost/ benefit analysis incorporating the inspection value method (IVM), is used to assist in making improved repair, replacement and rehabilitation decisions for selected drinking water distribution system pipes. A separate model is developed to predict failures in prestressed concrete cylinder pipe (PCCP). Various currently available inspection technologies are presented and discussed.
“Colored water” describes the appearance of drinking water that contains suspended particulate iron where the actual suspension color may range from light yellow to red due to water chemistry and particle properties. This iron can originate from the source water and f...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2013 CFR
2013-07-01
... parts of the distribution system; (4) Filtration and/or disinfection of surface water, as described in subparts H, P, T, and W of this part, or disinfection of ground water, as described in subpart S of this... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS National Primary Drinking...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2014 CFR
2014-07-01
... parts of the distribution system; (4) Filtration and/or disinfection of surface water, as described in subparts H, P, T, and W of this part, or disinfection of ground water, as described in subpart S of this... (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS National Primary Drinking...
This report documents the activities performed during and the results obtained from the first six months of the arsenic removal treatment technology demonstration project at the White Rock Water Company (WRWC) public water system, a small residential drinking water facility in Bo...
Hazra, Aniruddha
2013-01-01
A United Nations peacekeeping contingent was deployed in the conflict affected areas of South Sudan with inadequate environmental sanitation, lack of clean drinking water and a heightened risk of water-borne diseases. In the immediate post-deployment phase, the contingent-owned water purification system was pressed into service. However, laboratory analyses of processed water revealed its unsuitability for human consumption. A systematic, sanitary survey was conducted to identify the shortcomings in the water supply system's ability to provide potable water. Under field conditions, the 'H2S method' was used to detect faecal contamination of drinking water. The raw water from the only available source, the White Nile River, was highly turbid and contaminated by intestinal and other pathogens due to an unprotected watershed. Water sterilizing powder was not readily available in the local area to replenish the existing stocks that had deteriorated during the long transit period from the troop contributing country. The water pipelines that had been laid along the ground, under water-logged conditions, were prone to microbial recontamination due to leakages in the network. The critical evaluation of the water supply system and necessary modifications in the purification process, based upon locally available options, yielded safe drinking water. Provision of safe drinking water in the mission area requires an in-depth analysis of prevailing conditions and appropriate planning in the pre-deployment phase. The chemicals for water purification should be procured through UN sources via a 'letter of assist' request from the troop contributor. Copyright © 2012 Elsevier GmbH. All rights reserved.
Higham, C D; Horne, D; Singh, R; Kuhn-Sherlock, B; Scarsbrook, M R
2017-01-01
Water use in intensively managed, confinement dairy systems has been widely studied, but few reports exist regarding water use on pasture-based dairy farms. The objective of this study was to quantify the seasonal pattern of water use to develop a prediction model of water use for pasture-based dairy farms. Stock drinking, milking parlor, and total water use was measured on 35 pasture-based, seasonal calving dairy farms in New Zealand over 2 yr. Average stock drinking water was 60 L/cow per day, with peak use in summer. We estimated that, on average, 26% of stock drinking water was lost through leakage from water-distribution systems. Average corrected stock drinking water (equivalent to voluntary water intake) was 36 L/cow per day, and peak water consumption was 72 L/cow per day in summer. Milking parlor water use increased sharply at the start of lactation (July) and plateaued (August) until summer (February), after which it decreased with decreasing milk production. Average milking parlor water use was 58 L/cow per day (between September and February). Water requirements were affected by parlor type, with rotary milking parlor water use greater than herringbone parlor water use. Regression models were developed to predict stock drinking and milking parlor water use. The models included a range of climate, farm, and milk production variables. The main drivers of stock drinking water use were maximum daily temperature, potential evapotranspiration, radiation, and yield of milk and milk components. The main drivers for milking parlor water use were average per cow milk production and milking frequency. These models of water use are similar to those used in confinement dairy systems, where milk yield is commonly used as a variable. The models presented fit the measured data more accurately than other published models and are easier to use on pasture-based dairy farms, as they do not include feed and variables that are difficult to measure on pasture-based farms. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kingsbury, James A.; Barlow, Jeannie R.; Katz, Brian G.; Welch, Heather L.; Tollett, Roland W.; Fahlquist, Lynne S.
2015-01-01
About 8 million people rely on groundwater from the Mississippi embayment—Texas coastal uplands aquifer system for drinking water. The Mississippi River Valley alluvial aquifer also provides drinking water for domestic use in rural areas but is of primary importance to the region as a source of water for irrigation. Irrigation withdrawals from this aquifer are among the largest in the Nation and play a key role in the economy of the area, where annual crop sales total more than $7 billion. The reliance of the region on both aquifers for drinking water and irrigation highlights the importance of long-term management to sustain the availability and quality of these resources.
Drinking wate treatment in the US has played a major role in protecting public health through the reduction of wateborne disease. However, carcinogenic and toxic contaminants continue to threaten the quality of surface and ground water in the US. The passage of the Safe Drinking ...
Investigations into Monochloramine Biofilm Penetration
Biofilm in drinking water systems is undesirable. Free chlorine and monochloramine are commonly used as secondary drinking water disinfectants, but monochloramine is perceived to penetrate biofilm better than free chlorine. However, this hypothesis remains unconfirmed by direct b...
A WATERSHED APPROACH TO DRINKING WATER QUALITY
The purpose of this presentation is to describe emerging technologies and strategies managing watersheds with the goal of protecting drinking water sources. Included are discussions on decentralized wastewater treatment, whole organism biomonitor detection systems, treatment of...
[Parasitic zoonoses transmitted by drinking water. Giardiasis and cryptosporidiosis].
Exner, M; Gornik, V
2004-07-01
Nowadays, the parasitic zoonose organisms Giardia lamblia und Cryptosporidium spp. are among the most relevant pathogens of drinking water-associated disease outbreaks. These pathogens are transmitted via a fecal-oral route; in both cases the dose of infection is low. Apart from person-to-person or animal-to-person transmissions, the consumption of contaminated food and water are further modes of transmission. The disease is mainly characterized by gastrointestinal symptoms. In industrialized countries, the prevalence rate of giardiasis is 2-5 % and of cryptosporidiosis 1-3%. Throughout the world, a large number of giardiasis and cryptosporidiosis outbreaks associated with drinking water were published; in 2001 the first case in Germany was identified. Giardia and Cryptosporidium are detected in surface water and sporadically in unprotected groundwater. Use of these waters for drinking water abstraction makes high demands on the technology of the treatment process: because of the disinfectant resistance of the parasites, safe elimination methods are needed, which even at high contamination levels of source water guarantee safe drinking water. Further measures for prevention and control are implementation of the HACCP concept, which includes the whole chain of procedures of drinking water supply from catchment via treatment to tap and a quality management system.
New methods for the detection of viruses: call for review of drinking water quality guidelines.
Grabow, W O; Taylor, M B; de Villiers, J C
2001-01-01
Drinking water supplies which meet international recommendations for source, treatment and disinfection were analysed. Viruses recovered from 100 L-1,000 L volumes by in-line glass wool filters were inoculated in parallel into four cell culture systems. Cell culture inoculation was used to isolate cytopathogenic viruses, amplify the nucleic acid of non-cytopathogenic viruses and confirm viability of viruses. Over a period of two years, viruses were detected in 23% of 413 drinking water samples and 73% of 224 raw water samples. Cytopathogenic viruses were detected in 6% raw water samples but not in any treated drinking water supplies. Enteroviruses were detected in 17% drinking water samples, adenoviruses in 4% and hepatitis A virus in 3%. In addition to these viruses, astro- and rotaviruses were detected in raw water. All drinking water supplies had heterotrophic plate counts of < 100/mL, total and faecal coliform counts of 0/100 mL and negative results in qualitative presence-absence tests for somatic and F-RNA coliphages (500 mL samples). These results call for a revision of water quality guidelines based on indicator organisms and vague reference to the absence of viruses.
Diversity and Significance of Mold Species in Norwegian Drinking Water▿
Hageskal, Gunhild; Knutsen, Ann Kristin; Gaustad, Peter; de Hoog, G. Sybren; Skaar, Ida
2006-01-01
In order to determine the occurrence, distribution, and significance of mold species in groundwater- and surface water-derived drinking water in Norway, molds isolated from 273 water samples were identified. Samples of raw water, treated water, and water from private homes and hospital installations were analyzed by incubation of 100-ml membrane-filtered samples on dichloran-18% glycerol agar. The total count (number of CFU per 100 ml) of fungal species and the species diversity within each sample were determined. The identification of mold species was based on morphological and molecular methods. In total, 94 mold species belonging to 30 genera were identified. The mycobiota was dominated by species of Penicillium, Trichoderma, and Aspergillus, with some of them occurring throughout the drinking water system. Several of the same species as isolated from water may have the potential to cause allergic reactions or disease in humans. Other species are common contaminants of food and beverages, and some may cause unwanted changes in the taste or smell of water. The present results indicate that the mycobiota of water should be considered when the microbiological safety and quality of drinking water are assessed. In fact, molds in drinking water should possibly be included in the Norwegian water supply and drinking water regulations. PMID:17028226
WATERPROTECT: Innovative tools enabling drinking water protection in rural and urban environments
NASA Astrophysics Data System (ADS)
Seuntjens, Piet; Campling, Paul; Joris, Ingeborg; Wauters, Erwin; Lopez de Alda, Miren; Kuczynska, Anna; Lajer Hojberg, Anker; Capri, Ettore; Brabyn, Cristina; Boeckaert, Charlotte; Mellander, Per Erik; Pauwelyn, Ellen; Pop, Edit
2017-04-01
High-quality, safe, and sufficient drinking water is essential for life: we use it for drinking, food preparation and cleaning. Agriculture is the biggest source of pesticides and nitrate pollution in European fresh waters. The overarching objective of the recently approved H2020 project WATERPROTECT is to contribute to effective uptake and realisation of management practices and mitigation measures to protect drinking water resources. Therefore WATERPROTECT will create an integrative multi-actor participatory framework including innovative instruments that enable actors to monitor, to finance and to effectively implement management practices and measures for the protection of water sources. We propose seven case studies involving multiple actors in implementing good practices (land management, farming, product stewardship, point source pollution prevention) to ensure safe drinking water supply. The seven case studies cover different pedo-climatic conditions, different types of farming systems, different legal frameworks, larger and smaller water collection areas across the EU. In close cooperation with actors in the field in the case studies (farmers associations, local authorities, water producing companies, private water companies, consumer organisations) and other stakeholders (fertilizer and plant protection industry, environment agencies, nature conservation agencies, agricultural administrations) at local and EU level, WATERPROTECT will develop innovative water governance models investigating alternative pathways from focusing on the 'costs of water treatment' to 'rewarding water quality delivering farming systems'. Water governance structures will be built upon cost-efficiency analysis related to mitigation and cost-benefit analysis for society, and will be supported by spatially explicit GIS analyses and predictive models that account for temporal and spatial scaling issues. The outcome will be improved participatory methods and public policy instruments to protect drinking water resources.
Fungi from a Groundwater-Fed Drinking Water Supply System in Brazil
Oliveira, Helena M.B.; Santos, Cledir; Paterson, R. Russell M.; Gusmão, Norma B.; Lima, Nelson
2016-01-01
Filamentous fungi in drinking water distribution systems are known to (a) block water pipes; (b) cause organoleptic biodeterioration; (c) act as pathogens or allergens and (d) cause mycotoxin contamination. Yeasts might also cause problems. This study describes the occurrence of several fungal species in a water distribution system supplied by groundwater in Recife—Pernambuco, Brazil. Water samples were collected from four sampling sites from which fungi were recovered by membrane filtration. The numbers in all sampling sites ranged from 5 to 207 colony forming units (CFU)/100 mL with a mean value of 53 CFU/100 mL. In total, 859 isolates were identified morphologically, with Aspergillus and Penicillium the most representative genera (37% and 25% respectively), followed by Trichoderma and Fusarium (9% each), Curvularia (5%) and finally the species Pestalotiopsis karstenii (2%). Ramichloridium and Leptodontium were isolated and are black yeasts, a group that include emergent pathogens. The drinking water system in Recife may play a role in fungal dissemination, including opportunistic pathogens. PMID:27005653
Fungi from a Groundwater-Fed Drinking Water Supply System in Brazil.
Oliveira, Helena M B; Santos, Cledir; Paterson, R Russell M; Gusmão, Norma B; Lima, Nelson
2016-03-09
Filamentous fungi in drinking water distribution systems are known to (a) block water pipes; (b) cause organoleptic biodeterioration; (c) act as pathogens or allergens and (d) cause mycotoxin contamination. Yeasts might also cause problems. This study describes the occurrence of several fungal species in a water distribution system supplied by groundwater in Recife-Pernambuco, Brazil. Water samples were collected from four sampling sites from which fungi were recovered by membrane filtration. The numbers in all sampling sites ranged from 5 to 207 colony forming units (CFU)/100 mL with a mean value of 53 CFU/100 mL. In total, 859 isolates were identified morphologically, with Aspergillus and Penicillium the most representative genera (37% and 25% respectively), followed by Trichoderma and Fusarium (9% each), Curvularia (5%) and finally the species Pestalotiopsis karstenii (2%). Ramichloridium and Leptodontium were isolated and are black yeasts, a group that include emergent pathogens. The drinking water system in Recife may play a role in fungal dissemination, including opportunistic pathogens.
Patel, Anisha I; Grummon, Anna H; Hampton, Karla E; Oliva, Ariana; McCulloch, Charles E; Brindis, Claire D
2016-07-07
US legislation requires that schools offer free drinking water where meals are served. However, little information is available about what types of water delivery systems schools should install to meet such requirements. The study objective was to examine the efficacy and cost of 2 water delivery systems (water dispensers and bottleless water coolers) in increasing students' lunchtime intake of water in low-income middle schools. In 2013, twelve middle schools in the San Francisco Bay Area participated in a cluster randomized controlled trial in which they received 6 weeks of promotional activities, received provision of cups, and were assigned to 1 of 2 cafeteria water delivery systems: water dispensers or bottleless water coolers (or schools served as a control). Student surveys (n = 595) and observations examined the interventions' effect on students' beverage intake and staff surveys and public data assessed intervention cost. Analysis occurred from 2013 through 2015. Mixed-effects logistic regression, accounting for clustering and adjustment for student sociodemographic characteristics, demonstrated a significant increase in the odds of students drinking water in schools with promotion plus water dispensers and cups (adjusted odds ratio = 3.1; 95% confidence interval, 1.4-6.7; P = .004) compared with schools with traditional drinking fountains and no cups or promotion. The cost of dispenser and bottleless water cooler programs was similar ($0.04 per student per day). Instead of relying on traditional drinking fountains, schools should consider installing water sources, such as plastic dispensers with cups, as a low-cost, effective means for increasing students' water intake.
THE FORMATION OF PB(IV) OXIDES IN CHLORINATED WATER - PRESENTATION
Recent research has shown that Pb(IV) oxides can play an important geochemical role in drinking water distribution systems. The basis of most guidance for lead control in drinking water, however, presumes that Pb(II) solids control lead solubility. Therefore, it is important that...
Evaluation of Climate Change Impact on Drinking Water Treatment Plant Operation
It is anticipated that global climate change will adversely impact source water quality in many areas of the United States and, therefore, will influence the design and operation of current and future drinking water treatment systems. Some of these impacts may lead to violations ...
UV disinfection is an effective process for inactivating many microbial pathogens found in source waters with the potential as stand-alone treatment or in combination with other disinfectants. For surface and groundwater sourced drinking water applications, the U.S. Environmental...
Biofilm in drinking water systems is undesirable and may result in water quality degradation and subsequent non-compliance with existing regulations; therefore, effective biofilm control is desirable to maintain public health. For this purpose, drinking water utilities may use ei...
EVALUATION OF DRINKING WATER TREATMENT TECHNOLOGIES FOR REMOVAL OF ENDOCRINE DISRUPTING COMPOUNDS
Many of the chemicals identified as potential endocrine disrupting compounds (EDCs) may be present in surface or ground waters used as drinking water sources due to their introduction from domestic and industrial sewage treatment systems and wet-weather runoff. In order to dec...
Effects of an electrolyte additive on hydration and drinking behavior during wildfire suppression.
Cuddy, John S; Ham, Julie A; Harger, Stephanie G; Slivka, Dustin R; Ruby, Brent C
2008-01-01
The purpose of this study was to compare the effects of a water + electrolyte solution versus plain water on changes in drinking behaviors, hydration status, and body temperatures during wildfire suppression. Eight participants consumed plain water, and eight participants consumed water plus an electrolyte additive during 15 hours of wildfire suppression. Participants wore a specially outfitted backpack hydration system equipped with a digital flow meter system affixed inline to measure drinking characteristics (drinking frequency and volume). Body weight and urine-specific gravity were collected pre- and postshift. Ambient, core, and skin temperatures were measured continuously using a wireless system. Work output was monitored using accelerometry. There were no differences between groups for body weight, drinking frequency, temperature data, activity, or urine-specific gravity (1.019 +/- 0.007 to 1.023 +/- 0.010 vs. 1.019 +/- 0.005 to 1.024 +/- 0.009 for water and water + electrolyte groups pre- and postshift, respectively; P < .05). There was a main effect for time for body weight, demonstrating an overall decrease (78.1 +/- 13.3 and 77.3 +/- 13.3 kg pre- and postshift, respectively; P < .05) across the work shift. The water group consumed more total fluid (main effect for treatment) than the water + electrolyte group (504 +/- 472 vs. 285 +/- 279 mL.h(-1) for the water and water + electrolyte groups, respectively; P < .05). The addition of an electrolyte mixture to plain water decreased the overall fluid consumption of the water + electrolyte group by 220 mL.h(-1) (3.3 L.d(-1)). Supplementing water with electrolytes can reduce the amount of fluid necessary to consume and transport during extended activity. This can minimize carrying excessive weight, possibly reducing fatigue during extended exercise.
Wong, Michelle; Wolff, Craig; Collins, Natalie; Guo, Liang; Meltzer, Dan; English, Paul
2015-01-01
Significant illness is associated with biological contaminants in drinking water, but little is known about health effects from low levels of chemical contamination in drinking water. To examine these effects in epidemiological studies, the sources of drinking water of study populations need to be known. The California Environmental Health Tracking Program developed an online application that would collect data on the geographic location of public water system (PWS) customer service areas in California, which then could be linked to demographic and drinking water quality data. We deployed the Water Boundary Tool (WBT), a Web-based geospatial crowdsourcing application that can manage customer service boundary data for each PWS in California and can track changes over time. We also conducted a needs assessment for expansion to other states. The WBT was designed for water system operators, local and state regulatory agencies, and government entities. Since its public launch in 2012, the WBT has collected service area boundaries for about 2300 individual PWS, serving more than 90% of the California population. Results of the needs assessment suggest interest and utility for deploying such a tool among states lacking statewide PWS service area boundary data. Although the WBT data set is incomplete, it has already been used for a variety of applications, including fulfilling legislatively mandated reporting requirements and linking customer service areas to drinking water quality data to better understand local water quality issues. Development of this tool holds promise to assist with outbreak investigations and prevention, environmental health monitoring, and emergency preparedness and response.
The objective of this work is to compare the properties of lead solids formed during bench-scale precipitation experiments to solids found on lead pipe removed from real drinking water distribution systems and metal coupons used in pilot scale corrosion testing. Specifically, so...
Gumbo, B
2000-01-01
The Harare metropolis in Zimbabwe, extending upstream from Manyame Dam in the Upper Manyame River Basin, consists of the City of Harare and its satellite towns: Chitungwiza, Norton, Epworth and Ruwa. The existing urban drainage system is typically a single-use-mixing system: water is used and discharged to "waste", excreta are flushed to sewers and eventually, after "treatment", the effluent is discharged to a drinking water supply source. Polluted urban storm water is evacuated as fast as possible. This system not only ignores the substantial value in "waste" materials, but it also exports problems to downstream communities and to vulnerable fresh-water sources. The question is how can the harare metropolis urban drainage system, which is complex and has evolved over time, be rearranged to achieve sustainability (i.e. water conservation, pollution prevention at source, protection of the vulnerable drinking water sources and recovery of valuable materials)? This paper reviews current concepts regarding the future development of the urban drainage system in line with the new vision of "Sustainable Cities of the Future". The Harare Metropolis in Zimbabwe is taken as a case, and philosophical options for re-engineering the drainage system are discussed.
Decision support system for drinking water management
NASA Astrophysics Data System (ADS)
Janža, M.
2012-04-01
The problems in drinking water management are complex and often solutions must be reached under strict time constrains. This is especially distinct in case of environmental accidents in the catchment areas of the wells that are used for drinking water supply. The beneficial tools that can help decision makers and make program of activities more efficient are decision support systems (DSS). In general they are defined as computer-based support systems that help decision makers utilize data and models to solve unstructured problems. The presented DSS was developed in the frame of INCOME project which is focused on the long-term stable and safe drinking water supply in Ljubljana. The two main water resources Ljubljana polje and Barje alluvial aquifers are characterized by a strong interconnection of surface and groundwater, high vulnerability, high velocities of groundwater flow and pollutant transport. In case of sudden pollution, reactions should be very fast to avoid serious impact to the water supply. In the area high pressures arising from urbanization, industry, traffic, agriculture and old environmental burdens. The aim of the developed DSS is to optimize the activities in cases of emergency water management and to optimize the administrative work regarding the activities that can improve groundwater quality status. The DSS is an interactive computer system that utilizes data base, hydrological modelling, and experts' and stakeholders' knowledge. It consists of three components, tackling the different abovementioned issues in water management. The first one utilizes the work on identification, cleaning up and restoration of illegal dumpsites that are a serious threat to the qualitative status of groundwater. The other two components utilize the predictive capability of the hydrological model and scenario analysis. The user interacts with the system by a graphical interface that guides the user step-by-step to the recommended remedial measures. Consequently, the acquisition of information to support the water management's decisions is simplified and faster, thus contributing to more efficient water management and a safer supply of drinking water.
Literature Review of Associations among Attributes of Reported Drinking Water Disease Outbreaks
Ligon, Grant; Bartram, Jamie
2016-01-01
Waterborne disease outbreaks attributed to various pathogens and drinking water system characteristics have adversely affected public health worldwide throughout recorded history. Data from drinking water disease outbreak (DWDO) reports of widely varying breadth and depth were synthesized to investigate associations between outbreak attributes and human health impacts. Among 1519 outbreaks described in 475 sources identified during review of the primarily peer-reviewed, English language literature, most occurred in the U.S., the U.K. and Canada (in descending order). The outbreaks are most frequently associated with pathogens of unknown etiology, groundwater and untreated systems, and catchment realm-associated deficiencies (i.e., contamination events). Relative frequencies of outbreaks by various attributes are comparable with those within other DWDO reviews, with water system size and treatment type likely driving most of the (often statistically-significant at p < 0.05) differences in outbreak frequency, case count and attack rate. Temporal analysis suggests that while implementation of surface (drinking) water management policies is associated with decreased disease burden, further strengthening of related policies is needed to address the remaining burden attributed to catchment and distribution realm-associated deficiencies and to groundwater viral and disinfection-only system outbreaks. PMID:27240387
Literature Review of Associations among Attributes of Reported Drinking Water Disease Outbreaks.
Ligon, Grant; Bartram, Jamie
2016-05-27
Waterborne disease outbreaks attributed to various pathogens and drinking water system characteristics have adversely affected public health worldwide throughout recorded history. Data from drinking water disease outbreak (DWDO) reports of widely varying breadth and depth were synthesized to investigate associations between outbreak attributes and human health impacts. Among 1519 outbreaks described in 475 sources identified during review of the primarily peer-reviewed, English language literature, most occurred in the U.S., the U.K. and Canada (in descending order). The outbreaks are most frequently associated with pathogens of unknown etiology, groundwater and untreated systems, and catchment realm-associated deficiencies (i.e., contamination events). Relative frequencies of outbreaks by various attributes are comparable with those within other DWDO reviews, with water system size and treatment type likely driving most of the (often statistically-significant at p < 0.05) differences in outbreak frequency, case count and attack rate. Temporal analysis suggests that while implementation of surface (drinking) water management policies is associated with decreased disease burden, further strengthening of related policies is needed to address the remaining burden attributed to catchment and distribution realm-associated deficiencies and to groundwater viral and disinfection-only system outbreaks.
Drinking Water Consequences Tools. A Literature Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasqualini, Donatella
2016-05-12
In support of the goals of Department of Homeland Security’s (DHS) National Protection and Programs Directorate and the Federal Emergency Management Agency, the DHS Office of Science and Technology is seeking to develop and/or modify consequence assessment tools to enable drinking water systems owner/operators to estimate the societal and economic consequences of drinking water disruption due to the threats and hazards. This work will expand the breadth of consequence estimation methods and tools using the best-available data describing water distribution infrastructure, owner/assetlevel economic losses, regional-scale economic activity, and health. In addition, this project will deploy the consequence methodology and capabilitymore » within a Web-based platform. This report is intended to support DHS effort providing a review literature review of existing assessment tools of water and wastewater systems consequences to disruptions. The review includes tools that assess water systems resilience, vulnerability, and risk. This will help to understand gaps and limitations of these tools in order to plan for the development of the next-generation consequences tool for water and waste water systems disruption.« less
Bacterial Community Shift Drives Antibiotic Resistance Promotion during Drinking Water Chlorination.
Jia, Shuyu; Shi, Peng; Hu, Qing; Li, Bing; Zhang, Tong; Zhang, Xu-Xiang
2015-10-20
For comprehensive insights into the effects of chlorination, a widely used disinfection technology, on bacterial community and antibiotic resistome in drinking water, this study applied high-throughput sequencing and metagenomic approaches to investigate the changing patterns of antibiotic resistance genes (ARGs) and bacterial community in a drinking water treatment and distribution system. At genus level, chlorination could effectively remove Methylophilus, Methylotenera, Limnobacter, and Polynucleobacter, while increase the relative abundance of Pseudomonas, Acidovorax, Sphingomonas, Pleomonas, and Undibacterium in the drinking water. A total of 151 ARGs within 15 types were detectable in the drinking water, and chlorination evidently increased their total relative abundance while reduced their diversity in the opportunistic bacteria (p < 0.05). Residual chlorine was identified as the key contributing factor driving the bacterial community shift and resistome alteration. As the dominant persistent ARGs in the treatment and distribution system, multidrug resistance genes (mainly encoding resistance-nodulation-cell division transportation system) and bacitracin resistance gene bacA were mainly carried by chlorine-resistant bacteria Pseudomonas and Acidovorax, which mainly contributed to the ARGs abundance increase. The strong correlation between bacterial community shift and antibiotic resistome alteration observed in this study may shed new light on the mechanism behind the chlorination effects on antibiotic resistance.
Protecting drinking water utilities from cyberthreats
Clark, Robert M.; Panguluri, Srinivas; Nelson, Trent D.; ...
2017-02-01
Cyber-security challenges have the potential for becoming one of the defining issues of our time. Cyber-attacks have become an ever-increasing threat and the United States (US) Federal Bureau of Investigation (FBI) now ranks cyber-crime as one of its most important law enforcement activities. In addition to the general problems associated with cyber-crime, critical infrastructure (CI) related to energy production, manufacturing, water supply and other systems have come under attack. For example, drinking water utilities are increasingly incorporating computer technology into their routine operations and are therefore increasingly vulnerable to cyber- threats. Systems control and data acquisition (SCADA) systems used tomore » manage automated physical processes essential to water treatment and distribution systems have become standard in medium to large drinking water utilities and in many small water systems. However, even with the application of standard information technology cybersecurity best practices these types of systems have proven to be vulnerable to cyber-attacks. In 2015, the US Department of Homeland Security (DHS) responded to 25 cybersecurity incidents in the Water Sector and to 46 incidents in the Energy Sector. Comparatively, between 2014 and 2015, the reported number of Water Sector incidents actually increased by 78.6% (from 14 to 25). The DHS is in a collaborative partnership with the US Environmental Protection Agency to ensure cybersecurity in the Water Sector. As a result of this partnership a number of guidance documents and techniques have been developed to counter cyber-attacks and minimize cyber vulnerability. These approaches are documented along with a summary of common vulnerabilities. However, a new approach which has great promise in protecting drinking water systems against hacking and cyber-attacks, based on the concept of unidirectional gateways, is presented and discussed.« less
Protecting drinking water utilities from cyberthreats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, Robert M.; Panguluri, Srinivas; Nelson, Trent D.
Cyber-security challenges have the potential for becoming one of the defining issues of our time. Cyber-attacks have become an ever-increasing threat and the United States (US) Federal Bureau of Investigation (FBI) now ranks cyber-crime as one of its most important law enforcement activities. In addition to the general problems associated with cyber-crime, critical infrastructure (CI) related to energy production, manufacturing, water supply and other systems have come under attack. For example, drinking water utilities are increasingly incorporating computer technology into their routine operations and are therefore increasingly vulnerable to cyber- threats. Systems control and data acquisition (SCADA) systems used tomore » manage automated physical processes essential to water treatment and distribution systems have become standard in medium to large drinking water utilities and in many small water systems. However, even with the application of standard information technology cybersecurity best practices these types of systems have proven to be vulnerable to cyber-attacks. In 2015, the US Department of Homeland Security (DHS) responded to 25 cybersecurity incidents in the Water Sector and to 46 incidents in the Energy Sector. Comparatively, between 2014 and 2015, the reported number of Water Sector incidents actually increased by 78.6% (from 14 to 25). The DHS is in a collaborative partnership with the US Environmental Protection Agency to ensure cybersecurity in the Water Sector. As a result of this partnership a number of guidance documents and techniques have been developed to counter cyber-attacks and minimize cyber vulnerability. These approaches are documented along with a summary of common vulnerabilities. However, a new approach which has great promise in protecting drinking water systems against hacking and cyber-attacks, based on the concept of unidirectional gateways, is presented and discussed.« less