A Near-Surface Burst EMP Driver Package for Neutron-Induced Sources.
1980-09-01
FAa’S FD-F C SAwSB s3.sc 6O TO 10 C BEGIN NODIFIED QUADRATIC INTERPOLATION FOR NINlINUff 100 CONT INUE ICBIC.1 IFlIC.GTeICOUNT) 10 TO 110 YENP aISC-Sl) lSD ...M.I.T. LINCOLN LABORATORY Ro&.D ASSOCIATED P.O. DOE 369 P.O. BOX 73 P.O. 101x 9695 KttN F. A. SHAW AM LEONA WUoNLIN ATMN S- CLAY ROGERS CLEAIEILD. Ur
Use of optical technique for inspection of warpage of IC packages
NASA Astrophysics Data System (ADS)
Toh, Siew-Lok; Chau, Fook S.; Ong, Sim Heng
2001-06-01
The packaging of IC packages has changed over the years, form dual-in-line, wire-bond, and pin-through-hole in printed wiring board technologies in the 1970s to ball grid array, chip scale and surface mount technologies in the 1990s. Reliability has been a big problem for manufacturers for some moisture-sensitive packages. One of the potential problems in plastic IC packages is moisture-induced popcorn effect which can arise during the reflow process. Shearography is a non-destructive inspection technique that may be used to detect the delamination and warpage of IC packages. It is non-contacting and permits a full-field observation of surface displacement derivatives. Another advantage of this technique is that it is able to give the real-time formation of the fringes which indicate flaws in the IC package under real-time simulation condition of Surface Mount Technology (SMT) IR reflow profile. It is extremely fast and convenient to study the true behavior of the packaging deformation during the SMT process. It can be concluded that shearography has the potential for the real- time detection, in situ and non-destructive inspection of IC packages during the surface mount process.
Effecting aging time of epoxy molding compound to molding process for integrated circuit packaging
NASA Astrophysics Data System (ADS)
Tachapitunsuk, Jirayu; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon
2017-09-01
This research studied about effecting aging time of epoxy molding compound (EMC) that effect to reliability performance of integrated circuit (IC) package in molding process. Molding process is so important of IC packaging process for protecting IC chip (or die) from temperature and humidity environment using encapsulated EMC. For general molding process, EMC are stored in the frozen at 5°C and left at room temperature at 25 °C for aging time on self before molding of die onto lead frame is 24 hours. The aging time effect to reliability performance of IC package due to different temperature and humidity inside the package. In experiment, aging time of EMC were varied from 0 to 24 hours for molding process of SOIC-8L packages. For analysis, these packages were tested by x-ray and scanning acoustic microscope to analyze properties of EMC with an aging time and also analyzed delamination, internal void, and wire sweep inside the packages with different aging time. The results revealed that different aging time of EMC effect to properties and reliability performance of molding process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodenbeck, Christopher T; Girardi, Michael
Internal nodes of a constituent integrated circuit (IC) package of a multichip module (MCM) are protected from excessive charge during plasma cleaning of the MCM. The protected nodes are coupled to an internal common node of the IC package by respectively associated discharge paths. The common node is connected to a bond pad of the IC package. During MCM assembly, and before plasma cleaning, this bond pad receives a wire bond to a ground bond pad on the MCM substrate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gui, Ping
During the funding period of this award from May 1, 2014 through March 30, 2016, we have accomplished the design, implementation and measurement results of two laser driver chips: LpGBLD10+ which is a low-power single-channel 10Gb/s laser driver IC, and LDQ10P, which is a 4x10Gb/s driver array chip for High Energy Physics (HEP) applications. With new circuit techniques, the driver consumes a record-low power consumption, 31 mW @10Gb/s/channel and occupies a small area of 400 µm × 1750 µm for the single-channel driver IC and 1900umx1700um for the LDQ10P chip. These characteristics allow for both the LpGBLD10+ ICs and LDQ10P suitable candidatemore » for the Versatile Link PLUS (VL+) project, offering flexibility in configuring multiple Transmitters and receivers.« less
Natural gas applications for hybrid vehicles. Final report, October 1992-July 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentley, J.M.
1993-08-01
Hybrid vehicle technology holds the potential for improved efficiency and emissions compared with internal combustion (IC) engines and improved range and refueling convenience over electric vehicles. This study evaluated the potential for using natural gas as a hybrid vehicle fuel. Potential regulatory and market drivers were evaluated for hybrids generally and natural gas hybrids in specific. Heat engine options and other configuration issues were investigated to determine efficiency, emissions or other benefits of light- and heavy-duty hybrids. Several hybrid vehicle configurations were evaluated to determine the specific packaging attributes of natural gas in a hybrid configuration. Generally, conventional IC enginesmore » appear adequate for most emissions-sensitive hybrid applications with no great advantage being gained from using turbines or other more advanced heat engines. The largest technology barrier to a near-term hybrid is the weight of available or near-term batteries. Smaller, light-duty hybrid vehicles will be more sensitive to this weight handicap than larger vehicles such as the urban transit bus.« less
Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B
2016-07-01
Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.
NASA Astrophysics Data System (ADS)
Peanpunga, Udom; Ugsornrat, Kessararat; Thorlor, Panakamol; Sumithpibul, Chalermsak
2017-09-01
This research studied about an epoxy molding compound (EMC) floor life to reliability performance of integrated circuit (IC) package. Molding is the process for protecting the die of IC package form mechanical and chemical reaction from external environment by shaping EMC. From normal manufacturing process, the EMC is stored in the frozen at 5oC and left at around room temperature for aging time or floor life before molding process. The EMC floor life effect to its properties and reliability performance of IC package. Therefore, this work interested in varied the floor life of EMC before molding process to analyze properties of EMC such as spiral flow length, gelation time, and viscosity. In experiment, the floor life of EMC was varied to check the effect of its property to reliability performance. The EMC floor life were varied from 0 hours to 60 hours with a step of 12 hours and observed wire sweep, incomplete EMC, and delamination inside the packages for 3x3, 5x5 and 8x8 mm2 of QFN packages. The evaluation showed about clearly effect of EMC floor life to IC packaging reliability. EMC floor life is not any concern for EMC property, moldabilty, and reliability from 0 hours to 48 hours for molding process of 3x3,5x5 and 8x8 mm2 QFN packaging manufacturing
Pulsed laser ablation of IC packages for device failure analyses
NASA Astrophysics Data System (ADS)
Hong, Ming Hui; Mai, ZhiHong; Chen, G. X.; Thiam, Thomas; Song, Wen D.; Lu, Yongfeng; Soh, Chye E.; Chong, Tow Chong
2002-06-01
Pulsed laser ablation of mold compounds for IC packaging in air and with steam assistance is investigated. It is applied to decap IC packages and expose computer CPU dies for the device failure analyses. Compared with chemical decapping, the laser ablation has advantages of being fast speed, non- contact and dry processing. Laser ablation with the steam assistance results in higher ablation rate and wider ablated crater with much smoother surface morphology. It implies that the steam assisted laser ablation can achieve a faster and better quality laser processing. Audible acoustic wave and plasma optical signal diagnostics are also carried out to have a better understanding of the mechanisms behind. Light wavelength and laser fluence applied in the decapping are two important parameters. The 532 nm Nd:YAG laser decapping at a low laser fluence can achieve a large decapping area with a fine ablation profile. IC packages decapped by the laser ablation show good quality for the device failure analyses.
Flexible packaging of solid-state integrated circuit chips with elastomeric microfluidics
Zhang, Bowei; Dong, Quan; Korman, Can E.; Li, Zhenyu; Zaghloul, Mona E.
2013-01-01
A flexible technology is proposed to integrate smart electronics and microfluidics all embedded in an elastomer package. The microfluidic channels are used to deliver both liquid samples and liquid metals to the integrated circuits (ICs). The liquid metals are used to realize electrical interconnects to the IC chip. This avoids the traditional IC packaging challenges, such as wire-bonding and flip-chip bonding, which are not compatible with current microfluidic technologies. As a demonstration we integrated a CMOS magnetic sensor chip and associate microfluidic channels on a polydimethylsiloxane (PDMS) substrate that allows precise delivery of small liquid samples to the sensor. Furthermore, the packaged system is fully functional under bending curvature radius of one centimetre and uniaxial strain of 15%. The flexible integration of solid-state ICs with microfluidics enables compact flexible electronic and lab-on-a-chip systems, which hold great potential for wearable health monitoring, point-of-care diagnostics and environmental sensing among many other applications.
NASA Astrophysics Data System (ADS)
Murrill, Steven R.; Tipton, Charles W.; Self, Charles T.
1991-03-01
The dose absorbed in an integrated circuit (IC) die exposed to a pulse of low-energy electrons is a strong function of both electron energy and surrounding packaging materials. This report describes an experiment designed to measure how well the Integrated TIGER Series one-dimensional (1-D) electron transport simulation program predicts dose correction factors for a state-of-the-art IC package and package/printed circuit board (PCB) combination. These derived factors are compared with data obtained experimentally using thermoluminescent dosimeters (TLD's) and the FX-45 flash x-ray machine (operated in electron-beam (e-beam) mode). The results of this experiment show that the TIGER 1-D simulation code can be used to accurately predict FX-45 e-beam dose deposition correction factors for reasonably complex IC packaging configurations.
Development of the physics driver in NOAA Environmental Modeling System (NEMS)
NASA Astrophysics Data System (ADS)
Lei, H.; Iredell, M.; Tripp, P.
2016-12-01
As a key component of the Next Generation Global Prediction System (NGGPS), a physics driver is developed in the NOAA Environmental Modeling System (NEMS) in order to facilitate the research, development, and transition to operations of innovations in atmospheric physical parameterizations. The physics driver connects the atmospheric dynamic core, the Common Community Physics Package and the other NEMS-based forecast components (land, ocean, sea ice, wave, and space weather). In current global forecasting system, the physics driver has incorporated major existing physics packages including radiation, surface physics, cloud and microphysics, ozone, and stochastic physics. The physics driver is also applicable to external physics packages. The structure adjustment in NEMS by separating the PHYS trunk is to create an open physics package pool. This open platform is beneficial to the enhancement of U.S. weather forecast ability. In addition, with the universal physics driver, the NEMS can also be used for specific functions by connecting external target physics packages through physics driver. The test of its function is to connect a physics dust-radiation model in the system. Then the modified system can be used for dust storm prediction and forecast. The physics driver is also developed into a standalone form. This is to facilitate the development works on physics packages. The developers can save instant fields of meteorology data and snapshots from the running system , and then used them as offline driving data fields to test the new individual physics modules or small modifications to current modules. This prevents the run of whole system for every test.
Dynamical Competition of IC-Industry Clustering from Taiwan to China
NASA Astrophysics Data System (ADS)
Tsai, Bi-Huei; Tsai, Kuo-Hui
2009-08-01
Most studies employ qualitative approach to explore the industrial clusters; however, few research has objectively quantified the evolutions of industry clustering. The purpose of this paper is to quantitatively analyze clustering among IC design, IC manufacturing as well as IC packaging and testing industries by using the foreign direct investment (FDI) data. The Lotka-Volterra system equations are first adopted here to capture the competition or cooperation among such three industries, thus explaining their clustering inclinations. The results indicate that the evolution of FDI into China for IC design industry significantly inspire the subsequent FDI of IC manufacturing as well as IC packaging and testing industries. Since IC design industry lie in the upstream stage of IC production, the middle-stream IC manufacturing and downstream IC packing and testing enterprises tend to cluster together with IC design firms, in order to sustain a steady business. Finally, Taiwan IC industry's FDI amount into China is predicted to cumulatively increase, which supports the industrial clustering tendency for Taiwan IC industry. Particularly, the FDI prediction of Lotka-Volterra model performs superior to that of the conventional Bass model after the forecast accuracy of these two models are compared. The prediction ability is dramatically improved as the industrial mutualism among each IC production stage is taken into account.
NDAS Hardware Translation Layer Development
NASA Technical Reports Server (NTRS)
Nazaretian, Ryan N.; Holladay, Wendy T.
2011-01-01
The NASA Data Acquisition System (NDAS) project is aimed to replace all DAS software for NASA s Rocket Testing Facilities. There must be a software-hardware translation layer so the software can properly talk to the hardware. Since the hardware from each test stand varies, drivers for each stand have to be made. These drivers will act more like plugins for the software. If the software is being used in E3, then the software should point to the E3 driver package. If the software is being used at B2, then the software should point to the B2 driver package. The driver packages should also be filled with hardware drivers that are universal to the DAS system. For example, since A1, A2, and B2 all use the Preston 8300AU signal conditioners, then the driver for those three stands should be the same and updated collectively.
Common mental disorders in public transportation drivers in Lima, Peru.
Ruiz-Grosso, Paulo; Ramos, Mariana; Samalvides, Frine; Vega-Dienstmaier, Johann; Kruger, Hever
2014-01-01
Traffic related injuries are leading contributors to burden of disease worldwide. In developing countries a high proportion of them can be attributed to public transportation vehicles. Several mental disorders including alcohol and drug abuse, psychotic disorders, mental stress, productivity pressure, and low monetary income were found predictors of high rates of traffic related injuries in public transportation drivers. The goal of this study was to estimate the prevalence of common mental disorders in the population of public transportation drivers of buses and rickshaws in Lima, Peru. Cross sectional study. A sample of bus and rickshaw drivers was systematically selected from formal public transportation companies using a snowball approach. Participants completed self-administered questionnaires for assessing major depressive episode, anxiety symptoms, alcohol abuse, and burnout syndrome. Socio demographic information was also collected. The analyses consisted of descriptive measurement of outcomes taking into account both between and within cluster standard deviation (BCSD and WCSD). A total of 278 bus and 227 rickshaw drivers out of 25 companies agreed to participate in the study. BCSD for major depressive episode, anxiety symptoms and burnout syndrome was not found significant (p>0.05). The estimated prevalence of each variable was 13.7% (IC95%: 10.7-16.6%), 24.1% (IC95%: 19.4-28.8%) and 14.1% (IC95%: 10.8-17.4%) respectively. The estimated prevalence of alcohol abuse was 75.4% (IC95%: 69-81.7%, BCSD = 12.2%, WCSD = 41.9%, intra class correlation (ICC): 7.8%). Common mental disorders such as alcohol abuse, major depressive episode, anxiety symptoms and burnout syndrome presented higher rates in public transportation drivers than general population.
Standard semiconductor packaging for high-reliability low-cost MEMS applications
NASA Astrophysics Data System (ADS)
Harney, Kieran P.
2005-01-01
Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.
Standard semiconductor packaging for high-reliability low-cost MEMS applications
NASA Astrophysics Data System (ADS)
Harney, Kieran P.
2004-12-01
Microelectronic packaging technology has evolved over the years in response to the needs of IC technology. The fundamental purpose of the package is to provide protection for the silicon chip and to provide electrical connection to the circuit board. Major change has been witnessed in packaging and today wafer level packaging technology has further revolutionized the industry. MEMS (Micro Electro Mechanical Systems) technology has created new challenges for packaging that do not exist in standard ICs. However, the fundamental objective of MEMS packaging is the same as traditional ICs, the low cost and reliable presentation of the MEMS chip to the next level interconnect. Inertial MEMS is one of the best examples of the successful commercialization of MEMS technology. The adoption of MEMS accelerometers for automotive airbag applications has created a high volume market that demands the highest reliability at low cost. The suppliers to these markets have responded by exploiting standard semiconductor packaging infrastructures. However, there are special packaging needs for MEMS that cannot be ignored. New applications for inertial MEMS devices are emerging in the consumer space that adds the imperative of small size to the need for reliability and low cost. These trends are not unique to MEMS accelerometers. For any MEMS technology to be successful the packaging must provide the basic reliability and interconnection functions, adding the least possible cost to the product. This paper will discuss the evolution of MEMS packaging in the accelerometer industry and identify the main issues that needed to be addressed to enable the successful commercialization of the technology in the automotive and consumer markets.
Superconductive ADC Project Fabrication Package. Final Design Review Package (Briefing Charts)
2010-09-07
Simulation Results Iin 1.45mV 2.5Ω 1pH 4pH 100fF 310uA 1fΩ Ic = 300uA Rn = 0.8Ω Cs = 0.32pF Ic = 300uA Rn = 0.8Ω Cs = 0.32pF Iin Vout Vout Ic = 500uA Rn...0.55Ω Cs = 0.32pF ONR Superconductive ADC CLIN/SLIN 0001AD September 2010, Brad Perranoski Pg. 17 Modulator Design Documentation Comparator Design...Comparator Design - Cadence Schematic & Simulation Comparator Testbench Simulation Results 1.45mV 2.5Ω 1pH 4pH 100fF 310uA 1fΩSine wave 100uApk Iin Ic
Tuan, Chia-Chi; James, Nathan Pataki; Lin, Ziyin; Chen, Yun; Liu, Yan; Moon, Kyoung-Sik; Li, Zhuo; Wong, C P
2017-03-15
As microelectronics are trending toward smaller packages and integrated circuit (IC) stacks nowadays, underfill, the polymer composite filled in between the IC chip and the substrate, becomes increasingly important for interconnection reliability. However, traditional underfills cannot meet the requirements for low-profile and fine pitch in high density IC stacking packages. Post-applied underfills have difficulties in flowing into the small gaps between the chip and the substrate, while pre-applied underfills face filler entrapment at bond pads. In this report, we present a self-patterning underfilling technology that uses selective wetting of underfill on Cu bond pads and Si 3 N 4 passivation via surface energy engineering. This novel process, fully compatible with the conventional underfilling process, eliminates the issue of filler entrapment in typical pre-applied underfilling process, enabling high density and fine pitch IC die bonding.
Wen, Peng; Zhu, Ding-He; Feng, Kun; Liu, Fang-Jun; Lou, Wen-Yong; Li, Ning; Zong, Min-Hua; Wu, Hong
2016-04-01
A novel antimicrobial packaging material was obtained by incorporating cinnamon essential oil/β-cyclodextrin inclusion complex (CEO/β-CD-IC) into polylacticacid (PLA) nanofibers via electrospinning technique. The CEO/β-CD-IC was prepared by the co-precipitation method and SEM and FT-IR spectroscopy analysis indicated the successful formation of CEO/β-CD-IC, which improved the thermal stability of CEO. The CEO/β-CD-IC was then incorporated into PLA nanofibers by electrospinning and the resulting PLA/CEO/β-CD nanofilm showed better antimicrobial activity compared to PLA/CEO nanofilm. The minimum inhibitory concentration (MIC) of PLA/CEO/β-CD nanofilm against Escherichia coli and Staphylococcus aureus was approximately 1 mg/ml (corresponding CEO concentration 11.35 μg/ml) and minimum bactericidal concentration (MBC) was approximately 7 mg/ml (corresponding CEO concentration 79.45 μg/ml). Furthermore, compared with the casting method, the mild electrospinning process was more favorable for maintaining greater CEO in the obtained film. The PLA/CEO/β-CD nanofilm can effectively prolong the shelf life of pork, suggesting it has potential application in active food packaging. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Gaucher, Brian P. (Inventor); Grzyb, Janusz (Inventor); Liu, Duixian (Inventor); Pfeiffer, Ullrich R. (Inventor)
2008-01-01
Apparatus and methods are provided for packaging IC chips together with integrated antenna modules designed to provide a closed EM (electromagnetic) environment for antenna radiators, thereby allowing antennas to be designed independent from the packaging technology.
Present, future of automotive hybrid IC applications discussed
NASA Astrophysics Data System (ADS)
Matsuda, Nobuyoshi; Fukuoka, Atuhisa
1987-09-01
Hybrid ICs are presently utilized in various fields such as commercial televisions, VTRs, and audio devices, industrial usage of communication equipment, computers, terminals, and automobiles. Its applications and environments are various and diverse. The functions required for hybrid ICs vary from simple high density mounting for a system to the realization of high mechanisms with the application of function timing. The functions are properly used depending upon the system with its hybrid ICs and its circuit composition. Considering structure and reliability requirements for automotive hybrid ICs, an application example for hybrid ICs which use the package (COMPACT), will be discussed.
Alpha particle-induced soft errors in microelectronic devices. I
NASA Astrophysics Data System (ADS)
Redman, D. J.; Sega, R. M.; Joseph, R.
1980-03-01
The article provides a tutorial review and trend assessment of the problem of alpha particle-induced soft errors in VLSI memories. Attention is given to an analysis of the design evolution of modern ICs, and the characteristics of alpha particles and their origin in IC packaging are reviewed. Finally, the process of an alpha particle penetrating an IC is examined.
Warpage of QFN Package in Post Mold Cure Process of integrated circuit packaging
NASA Astrophysics Data System (ADS)
Sriwithoon, Nattha; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon
2017-09-01
This research studied about warpage of QFN package in post mold cure process of integrated circuit (IC) packages using pre-plated (PPF) leadframe. For IC package, epoxy molding compound (EMC) are molded by cross linking of compound stiffness but incomplete crosslinked network and leading the fully cured thermoset by post mold cure (PMC) process. The cure temperature of PMC can change microstructure of EMC in term of stress inside the package and effect to warpage of the package due to coefficient of thermal expansion (CTE) between EMC and leadframe. In experiment, cure temperatures were varied to check the effect of internal stress due to different cure temperature after completed post mold cure for TDFN 2×3 8L. The cure temperature were varied with 180 °C, 170 °C, 160 °C, and 150°C with cure time 4 and 6 hours, respectively. For analysis, the TDFN 2×3 8L packages were analyzed the warpage by thickness gauge and scanning acoustic microscope (SAM) after take the test samples out from the oven cure. The results confirmed that effect of different CTE between EMC and leadframe due to different cure temperature resulting to warpage of the TDFN 2×3 8L packages.
Capable Copper Electrodeposition Process for Integrated Circuit - substrate Packaging Manufacturing
NASA Astrophysics Data System (ADS)
Ghanbari, Nasrin
This work demonstrates a capable reverse pulse deposition methodology to influence gap fill behavior inside microvia along with a uniform deposit in the fine line patterned regions for substrate packaging applications. Interconnect circuitry in IC substrate packages comprises of stacked microvia that varies in depth from 20microm to 100microm with an aspect ratio of 0.5 to 1.5 and fine line patterns defined by photolithography. Photolithography defined pattern regions incorporate a wide variety of feature sizes including large circular pad structures with diameter of 20microm - 200microm, fine traces with varying widths of 3microm - 30microm and additional planar regions to define a IC substrate package. Electrodeposition of copper is performed to establish the desired circuit. Electrodeposition of copper in IC substrate applications holds certain unique challenges in that they require a low cost manufacturing process that enables a void-free gap fill inside the microvia along with uniform deposition of copper on exposed patterned regions. Deposition time scales to establish the desired metal thickness for such packages could range from several minutes to few hours. This work showcases a reverse pulse electrodeposition methodology that achieves void-free gap fill inside the microvia and uniform plating in FLS (Fine Lines and Spaces) regions with significantly higher deposition rates than traditional approaches. In order to achieve this capability, systematic experimental and simulation studies were performed. A strong correlation of independent parameters that govern the electrodeposition process such as bath temperature, reverse pulse plating parameters and the ratio of electrolyte concentrations is shown to the deposition kinetics and deposition uniformity in fine patterned regions and gap fill rate inside the microvia. Additionally, insight into the physics of via fill process is presented with secondary and tertiary current simulation efforts. Such efforts lead to show "smart" control of deposition rate at the top and bottom of via to avoid void formation. Finally, a parametric effect on grain size and the ensuing copper metallurgical characteristics of bulk copper is also shown to enable high reliability substrate packages for the IC packaging industry.
Neural Implants, Packaging for Biocompatible Implants, and Improving Fabricated Capacitors
NASA Astrophysics Data System (ADS)
Agger, Elizabeth Rose
We have completed the circuit design and packaging procedure for an NIH-funded neural implant, called a MOTE (Microscale Optoelectronically Transduced Electrode). Neural recording implants for mice have greatly advanced neuroscience, but they are often damaging and limited in their recording location. This project will result in free-floating implants that cause less damage, provide rapid electronic recording, and increase range of recording across the cortex. A low-power silicon IC containing amplification and digitization sub-circuits is powered by a dual-function gallium arsenide photovoltaic and LED. Through thin film deposition, photolithography, and chemical and physical etching, the Molnar Group and the McEuen Group (Applied and Engineering Physics department) will package the IC and LED into a biocompatible implant approximately 100microm3. The IC and LED are complete and we have begun refining this packaging procedure in the Cornell NanoScale Science & Technology Facility. ICs with 3D time-resolved imaging capabilities can image microorganisms and other biological samples given proper packaging. A portable, flat, easily manufactured package would enable scientists to place biological samples on slides directly above the Molnar group's imaging chip. We have developed a packaging procedure using laser cutting, photolithography, epoxies, and metal deposition. Using a flip-chip method, we verified the process by aligning and adhering a sample chip to a holder wafer. In the CNF, we have worked on a long-term metal-insulator-metal (MIM) capacitor characterization project. Former Fellow and continuing CNF user Kwame Amponsah developed the original procedure for the capacitor fabrication, and another former fellow, Jonilyn Longenecker, revised the procedure and began the arduous process of characterization. MIM caps are useful to clean room users as testing devices to verify electronic characteristics of their active circuitry. This project's objective is to determine differences in current-voltage (IV) and capacitor-voltage (CV) relationships across variations in capacitor size and dielectric type. This effort requires an approximately 20-step process repeated for two-to-six varieties (dependent on temperature and thermal versus plasma options) of the following dielectrics: HfO2, SiO2, Al2O3, TaOx, and TiO2.
An Integrated Multilevel Converter with Sigma Delta Control for LED Lighting
NASA Astrophysics Data System (ADS)
Gerber, Daniel L.
High brightness LEDs have become a mainstream lighting technology due to their efficiency, life span, and environmental benefits. As such, the lighting industry values LED drivers with low cost, small form factor, and long life span. Additional specifications that define a high quality LED driver are high efficiency, high power factor, wide-range dimming, minimal flicker, and a galvanically isolated output. The flyback LED driver is a popular topology that satisfies all these specifications, but it requires a bulky and costly flyback transformer. In addition, its passive methods for cancelling AC power ripple require electrolytic capacitors, which have been known to have life span issues. This dissertation details the design, construction, and verification of a novel LED driver that satisfies all the specifications. In addition, it does not require a flyback transformer or electrolytic capacitors, thus marking an improvement over the flyback driver on size, cost, and life span. This dissertation presents an integrated circuit (IC) LED driver, which features a pair of generalized multilevel converters that are controlled via sigma-delta modulation. The first is a multilevel rectifier responsible for power factor correction (PFC) and dimming. The PFC rectifier employs a second order sigma-delta loop to precisely control the input current harmonics and amplitude. The second is a bidirectional multilevel inverter used to cancel AC power ripple from the DC bus. This ripple-cancellation module transfers energy to and from a storage capacitor. It uses a first order sigma-delta loop with a preprogrammed waveform to swing the storage capacitor voltage. The system also contains an output stage that powers the LEDs with DC and provides for galvanic isolation. The output stage consists of an H-bridge stack that connects to the output through a small toroid transformer. The IC LED driver was simulated and prototyped on an ABCD silicon test chip. Testing and verification indicates functional performance for all the modules in the LED driver. The driver exhibits moderate efficiency at half voltage. Although the part was only testable to half voltage, loss models predict that its efficiency would be much higher at full voltage. The driver also meets specifications on the line current harmonics and ripple cancellation. This dissertation introduces multilevel circuit techniques to the IC and LED research space. The prototype's functional performance indicates that integrated multilevel converters are a viable topology for lighting and other similar applications.
Driver-receiver combined optical transceiver modules for bidirectional optical interconnection
NASA Astrophysics Data System (ADS)
Park, Hyo-Hoon; Kang, Sae-Kyoung; Kim, Do-Won; Nga, Nguyen T. H.; Hwang, Sung-Hwan; Lee, Tae-Woo
2008-02-01
We review a bidirectional optical link scheme for memory-interface applications. A driver-receiver combined optical transceiver (TRx) modules was demonstrated on an optical printed-circuit board (OPCB) platform. To select the bidirectional electric input/output signals, a driver-receiver combined TRx IC with a switching function was designed in 0.18-μm CMOS technology. The TRx IC was integrated with VCSEL/PD chips for optical link in the TRx module. The optical TRx module was assembled on a fiber-embedded OPCB, employing a 90°-bent fiber connector for 90° deflection of light beams between the TRx module and the OPCB. The TRx module and the 90° connector were passively assembled on the OPCB, using ferrule-type guide pins/ holes. Employing these constituent components, the bidirectional optical link between a pair of TRx modules has been successfully demonstrated up to 1.25 Gb/s on the OPCB.
Optical waveguide circuit board with a surface-mounted optical receiver array
NASA Astrophysics Data System (ADS)
Thomson, J. E.; Levesque, Harold; Savov, Emil; Horwitz, Fred; Booth, Bruce L.; Marchegiano, Joseph E.
1994-03-01
A photonic circuit board is fabricated for potential application to interchip and interboard parallel optical links. The board comprises photolithographically patterned polymer optical waveguides on a conventional glass-epoxy electrical circuit board and a surface-mounted integrated circuit (IC) package that optically and electrically couples to an optoelectronic IC. The waveguide circuits include eight-channel arrays of straights, cross-throughs, curves, self- aligning interconnects to multi-fiber ribbon, and out-of-plane turning mirrors. A coherent, fused bundle of optical fibers couples light between 45-deg waveguide mirrors and a GaAs receiver array in the IC package. The fiber bundle is easily aligned to the mirrors and the receivers and is amenable to surface mounting and hermetic sealing. The waveguide-receiver- array board achieved error-free data rates up to 1.25 Gbits/s per channel, and modal noise was shown to be negligible.
Thermoelectric infrared imaging sensors for automotive applications
NASA Astrophysics Data System (ADS)
Hirota, Masaki; Nakajima, Yasushi; Saito, Masanori; Satou, Fuminori; Uchiyama, Makoto
2004-07-01
This paper describes three low-cost thermoelectric infrared imaging sensors having a 1,536, 2,304, and 10,800 element thermoelectric focal plane array (FPA) respectively and two experimental automotive application systems. The FPAs are basically fabricated with a conventional IC process and micromachining technologies and have a low cost potential. Among these sensors, the sensor having 2,304 elements provide high responsivity of 5,500 V/W and a very small size with adopting a vacuum-sealed package integrated with a wide-angle ZnS lens. One experimental system incorporated in the Nissan ASV-2 is a blind spot pedestrian warning system that employs four infrared imaging sensors. This system helps alert the driver to the presence of a pedestrian in a blind spot by detecting the infrared radiation emitted from the person"s body. The system can also prevent the vehicle from moving in the direction of the pedestrian. The other is a rearview camera system with an infrared detection function. This system consists of a visible camera and infrared sensors, and it helps alert the driver to the presence of a pedestrian in a rear blind spot. Various issues that will need to be addressed in order to expand the automotive applications of IR imaging sensors in the future are also summarized. This performance is suitable for consumer electronics as well as automotive applications.
School Bus Driver Instructional Program. Instructor's Guide.
ERIC Educational Resources Information Center
Department of Transportation, Washington, DC. National Highway Safety Bureau.
A standardized and comprehensive school bus driver instructional program has been developed under contract with the Federal Government. The course has been organized to provide in one package a program for developing the minimum skills and knowledge needed by the school bus driver instructor, as well as those supplemental skills and knowledge…
ERIC Educational Resources Information Center
Chan, Kin Hang
2009-01-01
Purpose: The purpose of this paper, which is written in two parts, is to investigate empirically if intellectual capital (IC) has an impact on the financial aspects of organisational performance as well as attempting to identify the IC components that may be the drivers for the leading financial indicators of listed companies. The study sought…
ERIC Educational Resources Information Center
Chan, Kin Hang
2009-01-01
Purpose: The purpose of this paper, which is written in two parts, is to investigate empirically if intellectual capital (IC) has an impact on the financial aspects of organisational performance as well as attempting to identify the IC components that may be the drivers for the leading financial indicators of listed companies. The study sought…
Design and fabrication of a foldable 3D silicon based package for solid state lighting applications
NASA Astrophysics Data System (ADS)
Sokolovskij, R.; Liu, P.; van Zeijl, H. W.; Mimoun, B.; Zhang, G. Q.
2015-05-01
Miniaturization of solid state lighting (SSL) luminaires as well as reduction of packaging and assembly costs are of prime interest for the SSL lighting industry. A novel silicon based LED package for lighting applications is presented in this paper. The proposed design consists of 5 rigid Si tiles connected by flexible polyimide hinges with embedded interconnects (ICs). Electrical, optical and thermal characteristics were taken into consideration during design. The fabrication process involved polyimide (PI) application and patterning, aluminium interconnect integration in the flexible hinge, LED reflector cavity formation and metalization followed by through wafer DRIE etching for chip formation and release. A method to connect chip front to backside without TSVs was also integrated into the process. Post-fabrication wafer level assembly included LED mounting and wirebond, phosphor-based colour conversion and silicone encapsulation. The package formation was finalized by vacuum assisted wrapping around an assembly structure to form a 3D geometry, which is beneficial for omnidirectional lighting. Bending tests were performed on the flexible ICs and optical performance at different temperatures was evaluated. It is suggested that 3D packages can be expanded to platforms for miniaturized luminaire applications by combining monolithic silicon integration and system-in-package (SiP) technologies.
Integrated readout electronics for Belle II pixel detector
NASA Astrophysics Data System (ADS)
Blanco, R.; Leys, R.; Perić, I.
2018-03-01
This paper describes the readout components for Belle II that have been designed as integrated circuits. The ICs are connected to DEPFET sensor by bump bonding. Three types of ICs have been developed: SWITCHER for pixel matrix control, DCD for readout and digitizing of sensor signals and DHP for digital data processing. The ICs are radiation tolerant and use several novel features, such as the multiple-input differential amplifiers and the fast and radiation hard high-voltage drivers. SWITCHER and DCD have been developed at University of Heidelberg, Karlsruhe Institute of Technology (KIT) and DHP at Bonn University. The IC-development started in 2009 and was accomplished in 2016 with the submissions of final designs. The final ICs for Belle II pixel detector and the related measurement results will be presented in this contribution.
Qualification and Reliability for MEMS and IC Packages
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2004-01-01
Advanced IC electronic packages are moving toward miniaturization from two key different approaches, front and back-end processes, each with their own challenges. Successful use of more of the back-end process front-end, e.g. microelectromechanical systems (MEMS) Wafer Level Package (WLP), enable reducing size and cost. Use of direct flip chip die is the most efficient approach if and when the issues of know good die and board/assembly are resolved. Wafer level package solve the issue of known good die by enabling package test, but it has its own limitation, e.g., the I/O limitation, additional cost, and reliability. From the back-end approach, system-in-a-package (SIAP/SIP) development is a response to an increasing demand for package and die integration of different functions into one unit to reduce size and cost and improve functionality. MEMS add another challenging dimension to electronic packaging since they include moving mechanical elements. Conventional qualification and reliability need to be modified and expanded in most cases in order to detect new unknown failures. This paper will review four standards that already released or being developed that specifically address the issues on qualification and reliability of assembled packages. Exposures to thermal cycles, monotonic bend test, mechanical shock and drop are covered in these specifications. Finally, mechanical and thermal cycle qualification data generated for MEMS accelerometer will be presented. The MEMS was an element of an inertial measurement unit (IMU) qualified for NASA Mars Exploration Rovers (MERs), Spirit and Opportunity that successfully is currently roaring the Martian surface
Development and Packaging of Microsystems Using Foundry Services
1998-06-01
DEVELOPMENT AND PACKAGING OF MICROSYSTEMS USING FOUNDRY SERVICES Jeffrey T. Butler, BSEE, MSEE Captain, USAF Approved: Paul H . Ostdiek, PhD, Lt...structural polysilicon layers. CMOS Device Area Micromechanical Device Area arsenic-daped epitaxial layer >J1M* ’ MM t° H 0J n-type ailioon...Ö ♦ * ♦ m B 1 —i ft H 035 0.045 0.055 0.065 0.075 Power Applied to Driver (W) (b) Figure 4-4. (a) Driver output loading
Variational data assimilation system "INM RAS - Black Sea"
NASA Astrophysics Data System (ADS)
Parmuzin, Eugene; Agoshkov, Valery; Assovskiy, Maksim; Giniatulin, Sergey; Zakharova, Natalia; Kuimov, Grigory; Fomin, Vladimir
2013-04-01
Development of Informational-Computational Systems (ICS) for Data Assimilation Procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in: mathematical modeling; theory of adjoint equations and optimal control; inverse problems; numerical methods theory; numerical algebra and scientific computing. The problems discussed above are studied in the Institute of Numerical Mathematics of the Russian Academy of Science (INM RAS) in ICS for Personal Computers (PC). Special problems and questions arise while effective ICS versions for PC are being developed. These problems and questions can be solved with applying modern methods of numerical mathematics and by solving "parallelism problem" using OpenMP technology and special linear algebra packages. In this work the results on the ICS development for PC-ICS "INM RAS - Black Sea" are presented. In the work the following problems and questions are discussed: practical problems that can be studied by ICS; parallelism problems and their solutions with applying of OpenMP technology and the linear algebra packages used in ICS "INM - Black Sea"; Interface of ICS. The results of ICS "INM RAS - Black Sea" testing are presented. Efficiency of technologies and methods applied are discussed. The work was supported by RFBR, grants No. 13-01-00753, 13-05-00715 and by The Ministry of education and science of Russian Federation, project 8291, project 11.519.11.1005 References: [1] V.I. Agoshkov, M.V. Assovskii, S.A. Lebedev, Numerical simulation of Black Sea hydrothermodynamics taking into account tide-forming forces. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 5-31 [2] E.I. Parmuzin, V.I. Agoshkov, Numerical solution of the variational assimilation problem for sea surface temperature in the model of the Black Sea dynamics. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 69-94 [3] V.B. Zalesny, N.A. Diansky, V.V. Fomin, S.N. Moshonkin, S.G. Demyshev, Numerical model of the circulation of Black Sea and Sea of Azov. Russ. J. Numer. Anal. Math. Modelling (2012) 27, No.1, 95-111 [4] V.I. Agoshkov, S.V. Giniatulin, G.V. Kuimov. OpenMP technology and linear algebra packages in the variation data assimilation systems. - Abstracts of the 1-st China-Russia Conference on Numerical Algebra with Applications in Radiactive Hydrodynamics, Beijing, China, October 16-18, 2012. [5] Zakharova N.B., Agoshkov V.I., Parmuzin E.I., The new method of ARGO buoys system observation data interpolation. Russian Journal of Numerical Analysis and Mathematical Modelling. Vol. 28, Issue 1, 2013.
SiC Integrated Circuits for Power Device Drivers Able to Operate in Harsh Environments
NASA Astrophysics Data System (ADS)
Godignon, P.; Alexandru, M.; Banu, V.; Montserrat, J.; Jorda, X.; Vellvehi, M.; Schmidt, B.; Michel, P.; Millan, J.
2014-08-01
The currently developed SiC electronic devices are more robust to high temperature operation and radiation exposure damage than correspondingly rated Si ones. In order to integrate the existent SiC high power and high temperature electronics into more complex systems, a SiC integrated circuit (IC) technology capable of operation at temperatures substantially above the conventional ones is required. Therefore, this paper is a step towards the development of ICs-control electronics that have to attend the harsh environment power applications. Concretely, we present the development of SiC MESFET-based digital circuitry, able to integrate gate driver for SiC power devices. Furthermore, a planar lateral power MESFET is developed with the aim of its co-integration on the same chip with the previously mentioned SiC digital ICs technology. And finally, experimental results on SiC Schottky-gated devices irradiated with protons and electrons are presented. This development is based on the Tungsten-Schottky interface technology used for the fabrication of stable SiC Schottky diodes for the European Space Agency Mission BepiColombo.
Zeiler, Frederick Adam; Donnelly, Joseph; Nourallah, Basil; Thelin, Eric Peter; Calviello, Leanne; Smieleweski, Peter; Czosnyka, Marek; Ercole, Ari; Menon, David
2018-02-12
Impaired cerebrovascular reactivity has been associated with outcome following traumatic brain injury (TBI), but it is unknown how it is affected by trauma severity. Thus, we aimed to explore the relationship between intra-cranial (IC) and extra-cranial (EC) injury burden and cerebrovascular reactivity in TBI patients. We retrospectively included critically ill TBI patients. IC injury burden included detailed lesion and computerized tomography (CT) scoring (ie. Marshall, Rotterdam, Helsinki and Stockholm Scores) on admission. EC injury burden were characterized using the injury severity score (ISS) and APACHE II score. Pressure reactivity index (PRx), pulse amplitude index (PAx) and RAC were used to assess autoregulation/cerebrovascular reactivity. We used univariate and multi-variate logistic regression techniques to explore relationships between IC and EC injury burden and autoregulation indices. A total of 358 patients were assessed. ISS and all IC CT scoring systems were poor predictors of impaired cerebrovascular reactivity. Only subdural hematomas and thickness of SAH (p<0.05, respectively) were consistently associated with dysfunctional cerebrovascular reactivity. High age (p<0.01 for all) and admission APACHE II scores (p<0.05 for all) were the two variables strongest associated with abnormal cerebrovascular reactivity. In summary, diffuse IC injury markers (thickness of SAH and the presence of a SDH) and APACHE II were most associated with dysfunction in cerebrovascular reactivity after TBI. Standard CT scoring systems and evidence of macroscopic parenchymal damage are poor predictors, implicating potentially both microscopic injury patterns and host response as drivers of dysfunctional cerebrovascular reactivity. Age remains a major variable associated with cerebrovascular reactivity.
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices.
Vanhoestenberghe, A; Donaldson, N
2013-06-01
Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way we evaluate the suitability of both protection methods. We demonstrate how lifetime predictability is lost for very small hermetic packages and introduce a single parameter to compare different packages, with an equation to calculate the minimum sensitivity required from a test method to guarantee a given lifetime. In the second part of this paper, we review the literature on the corrosion of encapsulated integrated circuits (ICs) and, following a new analysis of published data, we propose an equation for the pre-corrosion lifetime of implanted ICs, and discuss the influence of the temperature, relative humidity, encapsulation and field-strength. As any new protection will be tested under accelerated conditions, we demonstrate the sensitivity of acceleration factors to some inaccurately known parameters. These results are relevant for any application of electronics working in a moist environment. Our comparison of encapsulation and hermetic packages suggests that both concepts may be suitable for future implants.
Pedal force determination respect to ride comfort
NASA Astrophysics Data System (ADS)
Mačužić, Slavica; Lukić, Jovanka; Glišović, Jasna; Miloradović, Danijela
2017-10-01
Automotive ergonomics is a set of knowledge which has a task to design a vehicle to make the passengers feel comfortable. Interior packaging represents an important stage in the vehicle design process, in order to enable the driver to every important aspect of movement. During the process of driving, the driver performs various movements of arms and legs, leading to a certain fatigue. Each seating position in the vehicle, contain certain boundary conditions, and for that reason it was necessary to examine how the seating position affects the driver possibilities. In this paper, the pedal forces were determined by application of Ramsis human model. Different human populations were taken into account. Correlation between subjects’ anthropometrics measures and the foot pedal force pedal was observed. Obtained results were significant input data for vehicle packaging.
NASA Astrophysics Data System (ADS)
Raskin, Glenn; Lebby, Michael S.; Carney, F.; Kazakia, M.; Schwartz, Daniel B.; Gaw, Craig A.
1997-04-01
The OPTOBUSTM family of products provides for high performance parallel interconnection utilizing optical links in a 10-bit wide bi-directional configuration. The link is architected to be 'transparent' in that it is totally asynchronous and dc coupled so that it can be treated as a perfect cable with extremely low skew and no losses. An optical link consists of two identical transceiver modules and a pair of connectorized 62.5 micrometer multi mode fiber ribbon cables. The OPTOBUSTM I link provides bi- directional functionality at 4 Gbps (400 Mbps per channel), while the OPTOBUSTM II link will offer the same capability at 8 Gbps (800 Mbps per channel). The transparent structure of the OPTOBUSTM links allow for an arbitrary data stream regardless of its structure. Both the OPTOBUSTM I and OPTOBUSTM II transceiver modules are packaged as partially populated 14 by 14 pin grid arrays (PGA) with optical receptacles on one side of the module. The modules themselves are composed of several elements; including passives, integrated circuits optoelectronic devices and optical interface units (OIUs) (which consist of polymer waveguides and a specially designed lead frame). The initial offering of the modules electrical interface utilizes differential CML. The CML line driver sinks 5 mA of current into one of two pins. When terminated with 50 ohm pull-up resistors tied to a voltage between VCC and VCC-2, the result is a differential swing of plus or minus 250 mV, capable of driving standard PECL I/Os. Future offerings of the OPTOBUSTM links will incorporate LVDS and PECL interfaces as well as CML. The integrated circuits are silicon based. For OPTOBUSTM I links, a 1.5 micrometer drawn emitter NPN bipolar process is used for the receiver and an enhanced 0.8 micrometer CMOS process for the laser driver. For OPTOBUSTM II links, a 0.8 micrometer drawn emitter NPN bipolar process is used for the receiver and the driver IC utilizes 0.8 micrometer BiCMOS technology. The OPTOBUSTM architecture uses AlGaAs vertical cavity surface emitting lasers (VCSELs) at 850 nm in conjunction with unique opto-electronic packaging concepts. Most laser based transmitter subsystems are incapable of carrying an arbitrary NRZ data stream at high data rates. The receiver subsystem utilizes a conventional GaAs PIN photo-detector. In parallel interconnect systems. The design must take into account the simultaneous switching noise from the neighboring systems. If not well controlled, the high density of the multiple interconnects can limit the sensitivity and therefore the performance of the system. The packaging approach of the VCSEL and PIN arrays allow for high bandwidths and provide the coupling mechanisms necessary to interface to the 62.5 micrometer multi mode fiber. To allow for extremely high electrical signals the OPTOBUSTM package utilizes a multilayer tape automated bonded (TAB) lead frame. The lead frame contains separate signal and ground layers. The ground layer successfully provides for a pseudo-coaxial environment (low inductance and effective signal coupling to the ground plane).
Volvo drivers' experiences with advanced crash avoidance and related technologies.
Eichelberger, Angela H; McCartt, Anne T
2014-01-01
Crash avoidance technologies can potentially prevent or mitigate many crashes, but their success depends in part on driver acceptance. Owners of 2010-2012 model Volvo vehicles with several technologies were interviewed about their experiences. Interviews were conducted in summer 2012 with 155 owners of vehicles with City Safety as a standard feature; 145 owners with an optional technology package that included adaptive cruise control, distance alert, collision warning with full auto brake (and pedestrian detection on certain models), driver alert control, and lane departure warning; and 172 owners with both City Safety and the technology package. The survey response rates were 21 percent for owners with City Safety, 30 percent for owners with the technology package, and 27 percent for owners with both. Ten percent of owners opted out before the telephone survey began, and 18 percent declined to participate when called. Despite some annoyance, most respondents always leave the systems on, although fewer do so for lane departure warning (59%). For each of the systems, at least 80 percent of respondents with the system would want it on their next vehicle. Many respondents reported safer driving habits with the systems (e.g., following less closely with adaptive cruise control, using turn signals more often with lane departure warning). Fewer respondents reported potentially unsafe behavior, such as allowing the vehicle to brake for them at least some of the time. About one third of respondents experienced autonomous braking when they believed they were at risk of crashing, and about one fifth of respondents thought it had prevented a crash. About one fifth of respondents with the technology package reported that they were confused or misunderstood which safety system had activated in their vehicle. Consistent with the results for early adopters in the previous survey of Volvo and Infiniti owners, the present survey found that driver acceptance of the technologies remains high, although less so for lane departure warning. This study is the first to report drivers' experiences with City Safety, a collision avoidance system provided as standard equipment on certain Volvo 2010-2012 models, and driver acceptance of this system was high, although not to the same extent as the optional forward collision avoidance system. Future research should continue to monitor drivers' experiences with these technologies as they become available in more vehicles.
Ruesch, Rodney; Jenkins, Philip N.; Ma, Nan
2004-03-09
There is disclosed apparatus and apparatus for impedance control to provide for controlling the impedance of a communication circuit using an all-digital impedance control circuit wherein one or more control bits are used to tune the output impedance. In one example embodiment, the impedance control circuit is fabricated using circuit components found in a standard macro library of a computer aided design system. According to another example embodiment, there is provided a control for an output driver on an integrated circuit ("IC") device to provide for forming a resistor divider network with the output driver and a resistor off the IC device so that the divider network produces an output voltage, comparing the output voltage of the divider network with a reference voltage, and adjusting the output impedance of the output driver to attempt to match the output voltage of the divider network and the reference voltage. Also disclosed is over-sampling the divider network voltage, storing the results of the over sampling, repeating the over-sampling and storing, averaging the results of multiple over sampling operations, controlling the impedance with a plurality of bits forming a word, and updating the value of the word by only one least significant bit at a time.
GBLD10+: a compact low-power 10 Gb/s VCSEL driver
Zhang, T.; Kulis, S.; Gui, P.; ...
2016-01-13
We report the design and implementation of the GBLD10+, a low-power 10 Gb/s VCSEL driver for High Energy Physics (HEP) applications. With new circuit techniques, the driver consumes only 31 mW and occupies a small area of 400 μm × 1750 μm including the IO PADs and sealrings. These characteristics allow for multiple GBLD10+ ICs to be assembled side by side in a compact module, with each one directly wire bonded to one VCSEL diode. Finally, this makes the GBLD10+ a suitable candidate for the Versatile Link PLUS (VL +) project, offering flexibility in configuring multiple transmitters and receivers.
Driver Education, English-Spanish. Learning Achievement Packages. Revised Edition.
ERIC Educational Resources Information Center
Rendon, Rene
This text contains three suggested driver education curriculum units and is intended for use in a bilingual education setting. Each unit is in Spanish and English. The three units are: (1) "Procedures in Driving," (2) "Car Maintenance," and (3) "Tires." Each unit contains information for the teacher, explanations and…
Driver Improvement Analyst; Basic Training Program. Student Study Guide.
ERIC Educational Resources Information Center
Hale, Allen
As part of the training package for Driver Improvement Analysts, this study guide is designed to serve as the basic reference source for the students/trainees. It reinforces and supplements subject material presented in the Instructor's Lesson Plans. Subjects covered are objectives and requirements, psychology of driving, characteristics of the…
NASA Astrophysics Data System (ADS)
McQuiddy, David N., Jr.; Sokolov, Vladimir
1990-12-01
The present conference discusses microwave filters, lightwave technology for microwave antennas, planar and quasi-planar guides, mixers and VCOs, cavity filters, discontinuity and coupling effects, control circuits, power dividers and phase shifters, microwave ICs, biological effects and medical applications, CAD and modeling for MMICs, directional couplers, MMIC design trends, microwave packaging and manufacturing, monolithic ICs, and solid-state devices and circuits. Also discussed are microwave and mm-wave superconducting technology, MICs for communication systems, the merging of optical and microwave technologies, microwave power transistors, ferrite devices, network measurements, advanced transmission-line structures, FET devices and circuits, field theory of IC discontinuities, active quasi-optical techniques, phased-array techniques and circuits, nonlinear CAD, sub-mm wave devices, and high power devices.
Chen, Chang Hao; McCullagh, Elizabeth A; Pun, Sio Hang; Mak, Peng Un; Vai, Mang I; Mak, Pui In; Klug, Achim; Lei, Tim C
2017-03-01
The ability to record and to control action potential firing in neuronal circuits is critical to understand how the brain functions. The objective of this study is to develop a monolithic integrated circuit (IC) to record action potentials and simultaneously control action potential firing using optogenetics. A low-noise and high input impedance (or low input capacitance) neural recording amplifier is combined with a high current laser/light-emitting diode (LED) driver in a single IC. The low input capacitance of the amplifier (9.7 pF) was achieved by adding a dedicated unity gain stage optimized for high impedance metal electrodes. The input referred noise of the amplifier is [Formula: see text], which is lower than the estimated thermal noise of the metal electrode. Thus, the action potentials originating from a single neuron can be recorded with a signal-to-noise ratio of at least 6.6. The LED/laser current driver delivers a maximum current of 330 mA, which is adequate for optogenetic control. The functionality of the IC was tested with an anesthetized Mongolian gerbil and auditory stimulated action potentials were recorded from the inferior colliculus. Spontaneous firings of fifth (trigeminal) nerve fibers were also inhibited using the optogenetic protein Halorhodopsin. Moreover, a noise model of the system was derived to guide the design. A single IC to measure and control action potentials using optogenetic proteins is realized so that more complicated behavioral neuroscience research and the translational neural disorder treatments become possible in the future.
Behavioral modeling of VCSELs for high-speed optical interconnects
NASA Astrophysics Data System (ADS)
Szczerba, Krzysztof; Kocot, Chris
2018-02-01
Transition from on-off keying to 4-level pulse amplitude modulation (PAM) in VCSEL based optical interconnects allows for an increase of data rates, at the cost of 4.8 dB sensitivity penalty. The resulting strained link budget creates a need for accurate VCSEL models for driver integrated circuit (IC) design and system level simulations. Rate equation based equivalent circuit models are convenient for the IC design, but system level analysis requires computationally efficient closed form behavioral models based Volterra series and neural networks. In this paper we present and compare these models.
Park, Jangwoon; Ebert, Sheila M; Reed, Matthew P; Hallman, Jason J
2016-03-01
Previously published statistical models of driving posture have been effective for vehicle design but have not taken into account the effects of age. The present study developed new statistical models for predicting driving posture. Driving postures of 90 U.S. drivers with a wide range of age and body size were measured in laboratory mockup in nine package conditions. Posture-prediction models for female and male drivers were separately developed by employing a stepwise regression technique using age, body dimensions, vehicle package conditions, and two-way interactions, among other variables. Driving posture was significantly associated with age, and the effects of other variables depended on age. A set of posture-prediction models is presented for women and men. The results are compared with a previously developed model. The present study is the first study of driver posture to include a large cohort of older drivers and the first to report a significant effect of age. The posture-prediction models can be used to position computational human models or crash-test dummies for vehicle design and assessment. © 2015, Human Factors and Ergonomics Society.
NASA Astrophysics Data System (ADS)
Mehta, Sohan Singh; Yeung, Marco; Mirza, Fahad; Raman, Thiagarajan; Longenbach, Travis; Morgan, Justin; Duggan, Mark; Soedibyo, Rio A.; Reidy, Sean; Rabie, Mohamed; Cho, Jae Kyu; Premachandran, C. S.; Faruqui, Danish
2018-03-01
In this paper, we demonstrate photosensitive polyimide (PSPI) profile optimization to effectively reduce stress concentrations and enable PSPI as protection package-induced stress. Through detailed package simulation, we demonstrate 45% reduction in stress as the sidewall angle (SWA) of PSPI is increased from 45 to 80 degrees in Cu pillar package types. Through modulation of coating and develop multi-step baking temperature and time, as well as dose energy and post litho surface treatments, we demonstrate a method for reliably obtaining PSPI sidewall angle >75 degree. Additionally, we experimentally validate the simulation findings that PSPI sidewall angle impacts chip package interaction (CPI). Finally, we conclude this paper with PSPI material and tool qualification requirements for future technology node based on current challenges.
Molecular Isotopic Distribution Analysis (MIDAs) with Adjustable Mass Accuracy
NASA Astrophysics Data System (ADS)
Alves, Gelio; Ogurtsov, Aleksey Y.; Yu, Yi-Kuo
2014-01-01
In this paper, we present Molecular Isotopic Distribution Analysis (MIDAs), a new software tool designed to compute molecular isotopic distributions with adjustable accuracies. MIDAs offers two algorithms, one polynomial-based and one Fourier-transform-based, both of which compute molecular isotopic distributions accurately and efficiently. The polynomial-based algorithm contains few novel aspects, whereas the Fourier-transform-based algorithm consists mainly of improvements to other existing Fourier-transform-based algorithms. We have benchmarked the performance of the two algorithms implemented in MIDAs with that of eight software packages (BRAIN, Emass, Mercury, Mercury5, NeutronCluster, Qmass, JFC, IC) using a consensus set of benchmark molecules. Under the proposed evaluation criteria, MIDAs's algorithms, JFC, and Emass compute with comparable accuracy the coarse-grained (low-resolution) isotopic distributions and are more accurate than the other software packages. For fine-grained isotopic distributions, we compared IC, MIDAs's polynomial algorithm, and MIDAs's Fourier transform algorithm. Among the three, IC and MIDAs's polynomial algorithm compute isotopic distributions that better resemble their corresponding exact fine-grained (high-resolution) isotopic distributions. MIDAs can be accessed freely through a user-friendly web-interface at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/midas/index.html.
Molecular Isotopic Distribution Analysis (MIDAs) with adjustable mass accuracy.
Alves, Gelio; Ogurtsov, Aleksey Y; Yu, Yi-Kuo
2014-01-01
In this paper, we present Molecular Isotopic Distribution Analysis (MIDAs), a new software tool designed to compute molecular isotopic distributions with adjustable accuracies. MIDAs offers two algorithms, one polynomial-based and one Fourier-transform-based, both of which compute molecular isotopic distributions accurately and efficiently. The polynomial-based algorithm contains few novel aspects, whereas the Fourier-transform-based algorithm consists mainly of improvements to other existing Fourier-transform-based algorithms. We have benchmarked the performance of the two algorithms implemented in MIDAs with that of eight software packages (BRAIN, Emass, Mercury, Mercury5, NeutronCluster, Qmass, JFC, IC) using a consensus set of benchmark molecules. Under the proposed evaluation criteria, MIDAs's algorithms, JFC, and Emass compute with comparable accuracy the coarse-grained (low-resolution) isotopic distributions and are more accurate than the other software packages. For fine-grained isotopic distributions, we compared IC, MIDAs's polynomial algorithm, and MIDAs's Fourier transform algorithm. Among the three, IC and MIDAs's polynomial algorithm compute isotopic distributions that better resemble their corresponding exact fine-grained (high-resolution) isotopic distributions. MIDAs can be accessed freely through a user-friendly web-interface at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/midas/index.html.
Stable Electrical Operation of 6H-SiC JFETs and ICs for Thousands of Hours at 500 C
NASA Technical Reports Server (NTRS)
Neudeck, Philip G.; Spry, David J.; Chen, Liang-Yu; Beheim, Glenn M.; Okojie, Robert S.; Chang, Carl W.; Meredith, Roger D.; Ferrier, Terry L.; Evans, Laura J.; Krasowski, Michael J.;
2008-01-01
The fabrication and testing of the first semiconductor transistors and small-scale integrated circuits (ICs) to achieve up to 3000 h of stable electrical operation at 500 C in air ambient is reported. These devices are based on an epitaxial 6H-SiC junction field-effect transistor process that successfully integrated high temperature ohmic contacts, dielectric passivation, and ceramic packaging. Important device and circuit parameters exhibited less than 10% of change over the course of the 500 C operational testing. These results establish a new technology foundation for realizing durable 500 C ICs for combustion-engine sensing and control, deep-well drilling, and other harsh-environment applications.
Experimental Durability Testing of 4H SiC JFET Integrated Circuit Technology at 727 C
NASA Technical Reports Server (NTRS)
Spry, David; Neudeck, Phil; Chen, Liangyu; Chang, Carl; Lukco, Dorothy; Beheim, Glenn M
2016-01-01
We have reported SiC integrated circuits (IC's) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 C [1, 2]. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 C [3]. However, this thermal ramp was not ended until a peak temperature of 880 C (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology. Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 C. In one test, the temperature was ramped and then held at 727 C, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 C before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 C (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 C.
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Chang, Carl W.; Lukco, Dorothy; Beheim, Glenn M.
2016-01-01
We have reported SiC integrated circuits (ICs) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 degrees Centigrade. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 degrees Centigrade. However, this thermal ramp was not ended until a peak temperature of 880 degrees Centigrade (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology.Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 degrees Centigrade. In one test, the temperature was ramped and then held at 727 degrees Centigrade, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 degrees Centigrade before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 degrees Centigrade (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 degrees Centigrade.
Stoves or Sugar? Willingness to Adopt Improved Cookstoves in Malawi
Jagger, Pamela; Jumbe, Charles
2016-01-01
Malawi has set a target of adoption of two million improved cookstoves (ICS) by 2020. Meeting this objective requires knowledge about determinants of adoption, particularly in rural areas where the cost of traditional cooking technologies and fuels are non-monetary, and where people have limited capacity to purchase an ICS. We conducted a discrete choice experiment with 383 households in rural Malawi asking them if they would chose a locally made ICS or a package of sugar and salt of roughly equal value. Six months later, we assessed adoption and stove use patterns. Sixty-six percent of households chose the ICS. We find that having a larger share of crop residues in household fuel supply, awareness of the environmental impacts of woodfuel reliance, time the primary cook devotes to collecting fuelwood, and peer effects at the village-level increase the odds of choosing the ICS. Having a large labor supply for fuelwood collection and experience with a non-traditional cooking technology decreased the odds of choosing the ICS. In a rapid assessment six months after stoves were distributed, we found 80% of households were still using the ICS, but not exclusively. Our findings suggest considerable potential for wide-scale adoption of ICS in Malawi. PMID:27346912
Xu, Yaomin; Guo, Xingyi; Sun, Jiayang; Zhao, Zhongming
2015-01-01
Motivation: Large-scale cancer genomic studies, such as The Cancer Genome Atlas (TCGA), have profiled multidimensional genomic data, including mutation and expression profiles on a variety of cancer cell types, to uncover the molecular mechanism of cancerogenesis. More than a hundred driver mutations have been characterized that confer the advantage of cell growth. However, how driver mutations regulate the transcriptome to affect cellular functions remains largely unexplored. Differential analysis of gene expression relative to a driver mutation on patient samples could provide us with new insights in understanding driver mutation dysregulation in tumor genome and developing personalized treatment strategies. Results: Here, we introduce the Snowball approach as a highly sensitive statistical analysis method to identify transcriptional signatures that are affected by a recurrent driver mutation. Snowball utilizes a resampling-based approach and combines a distance-based regression framework to assign a robust ranking index of genes based on their aggregated association with the presence of the mutation, and further selects the top significant genes for downstream data analyses or experiments. In our application of the Snowball approach to both synthesized and TCGA data, we demonstrated that it outperforms the standard methods and provides more accurate inferences to the functional effects and transcriptional dysregulation of driver mutations. Availability and implementation: R package and source code are available from CRAN at http://cran.r-project.org/web/packages/DESnowball, and also available at http://bioinfo.mc.vanderbilt.edu/DESnowball/. Contact: zhongming.zhao@vanderbilt.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25192743
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Liangyu, Chen; Evans, Laura J.; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.
2015-01-01
The fabrication and prolonged 500 C electrical testing of 4H-SiC junction field effect transistor (JFET) integrated circuits (ICs) with two levels of metal interconnect is reported in another submission to this conference proceedings. While some circuits functioned more than 1000 hours at 500 C, the majority of packaged ICs from this wafer electrically failed after less than 200 hours of operation in the same test conditions. This work examines the root physical degradation and failure mechanisms believed responsible for observed large discrepancies in 500 C operating time. Evidence is presented for four distinct issues that significantly impacted 500 C IC operational yield and lifetime for this wafer.
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Evans, Laura J.; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.
2015-01-01
The fabrication and prolonged 500 C electrical testing of 4H-SiC junction field effect transistor (JFET) integrated circuits (ICs) with two levels of metal interconnect is reported in another submission to this conference proceedings. While some circuits functioned more than 3000 hours at 500 C, the majority of packaged ICs from this wafer electrically failed after less than 200 hours of operation in the same test conditions. This work examines the root physical degradation and failure mechanisms believed responsible for observed large discrepancies in 500 C operating time. Evidence is presented for four distinct issues that significantly impacted 500 C IC operational yield and lifetime for this wafer.
NASA Technical Reports Server (NTRS)
1982-01-01
Tests to verify the as-designed performance of all circuits within the thematic mapper electronics module unit are described. Specifically, the tests involved the evaluation of the scan line corrector driver, shutter drivers function, cal lamp controller function, post amplifier function, command decoder verification unit, and the temperature and actuator controllers function.
Stitch-bond parallel-gap welding for IC circuits
NASA Technical Reports Server (NTRS)
Chvostal, P.; Tuttle, J.; Vanderpool, R.
1980-01-01
Stitch-bonded flatpacks are superior to soldered dual-in-lines where size, weight, and reliability are important. Results should interest designers of packaging for complex high-reliability electronics, such as that used in security systems, industrial process control, and vehicle electronics.
Electro-Microfluidic Packaging
NASA Astrophysics Data System (ADS)
Benavides, G. L.; Galambos, P. C.
2002-06-01
There are many examples of electro-microfluidic products that require cost effective packaging solutions. Industry has responded to a demand for products such as drop ejectors, chemical sensors, and biological sensors. Drop ejectors have consumer applications such as ink jet printing and scientific applications such as patterning self-assembled monolayers or ejecting picoliters of expensive analytes/reagents for chemical analysis. Drop ejectors can be used to perform chemical analysis, combinatorial chemistry, drug manufacture, drug discovery, drug delivery, and DNA sequencing. Chemical and biological micro-sensors can sniff the ambient environment for traces of dangerous materials such as explosives, toxins, or pathogens. Other biological sensors can be used to improve world health by providing timely diagnostics and applying corrective measures to the human body. Electro-microfluidic packaging can easily represent over fifty percent of the product cost and, as with Integrated Circuits (IC), the industry should evolve to standard packaging solutions. Standard packaging schemes will minimize cost and bring products to market sooner.
ERIC Educational Resources Information Center
Kimball, Jeffrey P.; And Others
1987-01-01
Describes a variety of computer software. The packages reviewed include a variety of simulations, a spread sheet, a printer driver and an alternative operating system for DBM.PCs and compatible programs. (BSR)
113Gb/s (10 x 11.3Gb/s) ultra-low power EAM driver array.
Vaernewyck, Renato; Bauwelinck, Johan; Yin, Xin; Pierco, Ramses; Verbrugghe, Jochen; Torfs, Guy; Li, Zhisheng; Qiu, Xing-Zhi; Vandewege, Jan; Cronin, Richard; Borghesani, Anna; Moodie, David
2013-01-14
This paper presents an ultra-low power SiGe BiCMOS IC for driving a 10 channel electro-absorption modulator (EAM) array at 113Gb/s for wavelength division multiplexing passive optical network (WDM-PON) applications. With an output swing of 2.5V(pp), the EAM driver array consumes only 2.2W or 220mW per channel, 50% below the state of the art. Both the output swing and bias are configurable between 1.5 and 3.0V(pp) and 0.75-2.15V respectively.
Halonen, Niina; Kilpijärvi, Joni; Sobocinski, Maciej; Datta-Chaudhuri, Timir; Hassinen, Antti; Prakash, Someshekar B; Möller, Peter; Abshire, Pamela; Kellokumpu, Sakari; Lloyd Spetz, Anita
2016-01-01
Cell viability monitoring is an important part of biosafety evaluation for the detection of toxic effects on cells caused by nanomaterials, preferably by label-free, noninvasive, fast, and cost effective methods. These requirements can be met by monitoring cell viability with a capacitance-sensing integrated circuit (IC) microchip. The capacitance provides a measurement of the surface attachment of adherent cells as an indication of their health status. However, the moist, warm, and corrosive biological environment requires reliable packaging of the sensor chip. In this work, a second generation of low temperature co-fired ceramic (LTCC) technology was combined with flip-chip bonding to provide a durable package compatible with cell culture. The LTCC-packaged sensor chip was integrated with a printed circuit board, data acquisition device, and measurement-controlling software. The packaged sensor chip functioned well in the presence of cell medium and cells, with output voltages depending on the medium above the capacitors. Moreover, the manufacturing of microfluidic channels in the LTCC package was demonstrated.
Thermal Conductivity of Carbon Nanotube Composite Films
NASA Technical Reports Server (NTRS)
Ngo, Quoc; Cruden, Brett A.; Cassell, Alan M.; Walker, Megan D.; Koehne, Jessica E.; Meyyappan, M.; Li, Jun; Yang, Cary Y.
2004-01-01
State-of-the-art ICs for microprocessors routinely dissipate power densities on the order of 50 W/sq cm. This large power is due to the localized heating of ICs operating at high frequencies, and must be managed for future high-frequency microelectronic applications. Our approach involves finding new and efficient thermally conductive materials. Exploiting carbon nanotube (CNT) films and composites for their superior axial thermal conductance properties has the potential for such an application requiring efficient heat transfer. In this work, we present thermal contact resistance measurement results for CNT and CNT-Cu composite films. It is shown that Cu-filled CNT arrays enhance thermal conductance when compared to as-grown CNT arrays. Furthermore, the CNT-Cu composite material provides a mechanically robust alternative to current IC packaging technology.
Bollen, Sander; Leddin, Mathias; Andrade-Navarro, Miguel A; Mah, Nancy
2014-05-15
The current methods available to detect chromosomal abnormalities from DNA microarray expression data are cumbersome and inflexible. CAFE has been developed to alleviate these issues. It is implemented as an R package that analyzes Affymetrix *.CEL files and comes with flexible plotting functions, easing visualization of chromosomal abnormalities. CAFE is available from https://bitbucket.org/cob87icW6z/cafe/ as both source and compiled packages for Linux and Windows. It is released under the GPL version 3 license. CAFE will also be freely available from Bioconductor. sander.h.bollen@gmail.com or nancy.mah@mdc-berlin.de Supplementary data are available at Bioinformatics online.
Basic linear algebra subprograms for FORTRAN usage
NASA Technical Reports Server (NTRS)
Lawson, C. L.; Hanson, R. J.; Kincaid, D. R.; Krogh, F. T.
1977-01-01
A package of 38 low level subprograms for many of the basic operations of numerical linear algebra is presented. The package is intended to be used with FORTRAN. The operations in the package are dot products, elementary vector operations, Givens transformations, vector copy and swap, vector norms, vector scaling, and the indices of components of largest magnitude. The subprograms and a test driver are available in portable FORTRAN. Versions of the subprograms are also provided in assembly language for the IBM 360/67, the CDC 6600 and CDC 7600, and the Univac 1108.
NASA Astrophysics Data System (ADS)
Ahi, Kiarash; Shahbazmohamadi, Sina; Asadizanjani, Navid
2018-05-01
In this paper, a comprehensive set of techniques for quality control and authentication of packaged integrated circuits (IC) using terahertz (THz) time-domain spectroscopy (TDS) is developed. By material characterization, the presence of unexpected materials in counterfeit components is revealed. Blacktopping layers are detected using THz time-of-flight tomography, and thickness of hidden layers is measured. Sanded and contaminated components are detected by THz reflection-mode imaging. Differences between inside structures of counterfeit and authentic components are revealed through developing THz transmission imaging. For enabling accurate measurement of features by THz transmission imaging, a novel resolution enhancement technique (RET) has been developed. This RET is based on deconvolution of the THz image and the THz point spread function (PSF). The THz PSF is mathematically modeled through incorporating the spectrum of the THz imaging system, the axis of propagation of the beam, and the intensity extinction coefficient of the object into a Gaussian beam distribution. As a result of implementing this RET, the accuracy of the measurements on THz images has been improved from 2.4 mm to 0.1 mm and bond wires as small as 550 μm inside the packaging of the ICs are imaged.
Graham, Anthony H D; Robbins, Jon; Bowen, Chris R; Taylor, John
2011-01-01
The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented.
VizieR Online Data Catalog: Galaxy And Mass Assembly (GAMA): DR2 (Liske+, 2015)
NASA Astrophysics Data System (ADS)
Liske, J.; Baldry, I. K.; Driver, S. P.; Tuffs, R. J.; Alpaslan, M.; Andrae, E.; Brough, S.; Cluver, M. E.; Grootes, M. W.; Gunawardhana, M. L. P.; Kelvin, L. S.; Loveday, J.; Robotham, A. S. G.; Taylor, E. N.; Bamford, S. P.; Bland-Hawthorn, J.; Brown, M. J. I.; Drinkwater, M.; Hopkins, A. M.; Meyer, M. J.; Norberg, P.; Peacock, J. A.; Agius, N. K.; Andrews, S. K.; Bauer, A. E.; Ching, J. H. Y.; Colless, M.; Conselice, C. J.; Croom, S. M.; Davies, L. J. M.; de Propris, R.; Dunne, L.; Eardley, E. M.; Ellis, S.; Foster, C.; Frenk, C. S.; Haussler, B.; Holwerda, B. W.; Howlett, C.; Ibarra, H.; Jarvis, M. J.; Jones, D. H.; Kafle, P. R.; Lacey, C. G.; Lange, R.; Lara-Lopez, M. A.; Lopez-Sanchez, A. R.; Maddox, S.; Madore, B. F.; McNaught-Roberts, T.; Moffett, A. J.; Nichol, R. C.; Owers, M. S.; Palamara, D.; Penny, S. J.; Phillipps, S.; Pimbblet, K. A.; Popescu, C. C.; Prescott, M.; Proctor, R.; Sadler, E. M.; Sansom, A. E.; Seibert, M.; Sharp, R.; Sutherland, W.; Vazquez-Mata, J. A.; van Kampen, E.; Wilkins, S. M.; Williams, R.; Wright, A. H.
2016-02-01
Following the first three years of survey operations (2008 February-2010 May; see Driver et al. 2011MNRAS.413..971D, Cat. J/MNRAS/413/971) the GAMA spectroscopic survey on the AAT was substantially expanded, resulting in a number of significant changes to the GAMA IC and target selection. Here (and in other GAMA publications), the term 'GAMA I' refers to the data collected during these first three years, and to all data products that can be traced back to the original version of the IC (called InputCatAv05). In contrast, the term 'GAMA II' refers to the entire GAMA data set, including all GAMA I and all subsequently collected data, and all data products that can be traced back to the revised version of the IC (InputCatAv06 for the equatorial survey regions). (2 data files).
Effects of Initial Conditions on Shock Driven Flows
NASA Astrophysics Data System (ADS)
Martinez, Adam A.; Mula, Swathi M.; Charonko, John; Prestridge, Kathy
2017-11-01
The spatial and temporal evolution of shock-driven, variable density flows, such as the Richtmyer Meshkov (RM) instability, are strongly influenced by the initial conditions (IC's) of the flow at the time of interaction with shockwave. We study the effects of the IC's on the Vertical Shock Tube (VST) and on flows from Mach =1.2 to Mach =9. Experiments at the VST are of an Air-SF6 (At =0.6) multimode interface. Perturbations are generated using a shear layer with a flapper plate. Planar Laser Induced Fluorescence (PLIF) is used to characterize the IC's. New experiments are occurring using the Powder Gun driver at LANL Proton Radiography (pRad) facility. Mach number up to M =9 accelerate a Xenon-Helium (At =0.94) interface that is perturbed using a membrane supported by different sized grids. This presentation focuses on how to design and characterize different types of initial conditions for experiments.
High performance thyratron driver with low jitter.
Verma, Rishi; Lee, P; Springham, S V; Tan, T L; Rawat, R S
2007-08-01
We report the design and development of insulated gate bipolar junction transistor based high performance driver for operating thyratrons in grounded grid mode. With careful design, the driver meets the specification of trigger output pulse rise time less than 30 ns, jitter less than +/-1 ns, and time delay less than 160 ns. It produces a -600 V pulse of 500 ns duration (full width at half maximum) at repetition rate ranging from 1 Hz to 1.14 kHz. The developed module also facilitates heating and biasing units along with protection circuitry in one complete package.
Snyder, Hannah; Yeldandi, Vijay V; Prem Kumar, G; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A
2012-08-01
In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. A total of 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one-third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care.
Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.
2013-01-01
In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. Those who had previously been tested preferred traditional methods to video counseling. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care. PMID:22827901
The instrument control software package for the Habitable-Zone Planet Finder spectrometer
NASA Astrophysics Data System (ADS)
Bender, Chad F.; Robertson, Paul; Stefansson, Gudmundur Kari; Monson, Andrew; Anderson, Tyler; Halverson, Samuel; Hearty, Frederick; Levi, Eric; Mahadevan, Suvrath; Nelson, Matthew; Ramsey, Larry; Roy, Arpita; Schwab, Christian; Shetrone, Matthew; Terrien, Ryan
2016-08-01
We describe the Instrument Control Software (ICS) package that we have built for The Habitable-Zone Planet Finder (HPF) spectrometer. The ICS controls and monitors instrument subsystems, facilitates communication with the Hobby-Eberly Telescope facility, and provides user interfaces for observers and telescope operators. The backend is built around the asynchronous network software stack provided by the Python Twisted engine, and is linked to a suite of custom hardware communication protocols. This backend is accessed through Python-based command-line and PyQt graphical frontends. In this paper we describe several of the customized subsystem communication protocols that provide access to and help maintain the hardware systems that comprise HPF, and show how asynchronous communication benefits the numerous hardware components. We also discuss our Detector Control Subsystem, built as a set of custom Python wrappers around a C-library that provides native Linux access to the SIDECAR ASIC and Hawaii-2RG detector system used by HPF. HPF will be one of the first astronomical instruments on sky to utilize this native Linux capability through the SIDECAR Acquisition Module (SAM) electronics. The ICS we have created is very flexible, and we are adapting it for NEID, NASA's Extreme Precision Doppler Spectrometer for the WIYN telescope; we will describe this adaptation, and describe the potential for use in other astronomical instruments.
Passmore, Brandon; Cole, Zach; Whitaker, Bret; Barkley, Adam; McNutt, Ty; Lostetter, Alexander
2016-08-02
A multichip power module directly connecting the busboard to a printed-circuit board that is attached to the power substrate enabling extremely low loop inductance for extreme environments such as high temperature operation. Wire bond interconnections are taught from the power die directly to the busboard further enabling enable low parasitic interconnections. Integration of on-board high frequency bus capacitors provide extremely low loop inductance. An extreme environment gate driver board allows close physical proximity of gate driver and power stage to reduce overall volume and reduce impedance in the control circuit. Parallel spring-loaded pin gate driver PCB connections allows a reliable and reworkable power module to gate driver interconnections.
A three-channel LED driver with single line transportation technique
NASA Astrophysics Data System (ADS)
Yu, Caideng; Du, Yiying; Jiang, Qiao; Zhou, Yun; Lv, Jian
2012-10-01
Designed a three-channel LED driver, realized the single-wire transmission of cascade signal between the drive IC of LED. Including the MCU digital interface, date register, clock synchronization, PWM grayscale adjustment circuit, as well as high voltage driver circuit for LED, etc… The driver control LED displaying 256 gray. Chip will generate synchronous sampling clock signals according to the received serial signals, when 24 bits dates have been received, the output pin begins to transport the dates followed-up which are automotive shaped to the input of the next chip. When the date receiving becomes low level that represent RESET, the red, green and blue channels will export different signals based on different input dates. Through the external MCU, it is realized the Separate luminance, and by connecting chips in series it achieved the control of outdoor big screen' colorful display. The automatic shaping forward technique makes the number of chips cascading immune to the limitations of signal transmission, but only limited by the refresh speed.
Symmetric miniaturized heating system for active microelectronic devices.
McCracken, Michael; Mayer, Michael; Jourard, Isaac; Moon, Jeong-Tak; Persic, John
2010-07-01
To qualify interconnect technologies such as microelectronic fine wire bonds for mass production of integrated circuit (IC) packages, it is necessary to perform accelerated aging tests, e.g., to age a device at an elevated temperature or to subject the device to thermal cycling and measure the decrease of interconnect quality. There are downsides to using conventional ovens for this as they are relatively large and have relatively slow temperature change rates, and if electrical connections are required between monitoring equipment and the device being heated, they must be located inside the oven and may be aged by the high temperatures. Addressing these downsides, a miniaturized heating system (minioven) is presented, which can heat individual IC packages containing the interconnects to be tested. The core of this system is a piece of copper cut from a square shaped tube with high resistance heating wire looped around it. Ceramic dual in-line packages are clamped against either open end of the core. One package contains a Pt100 temperature sensor and the other package contains the device to be aged placed in symmetry to the temperature sensor. According to the temperature detected by the Pt100, a proportional-integral-derivative controller adjusts the power supplied to the heating wire. The system maintains a dynamic temperature balance with the core hot and the two symmetric sides with electrical connections to the device under test at a cooler temperature. Only the face of the package containing the device is heated, while the socket holding it remains below 75 degrees C when the oven operates at 200 degrees C. The minioven can heat packages from room temperature up to 200 degrees C in less than 5 min and maintain this temperature at 28 W power. During long term aging, a temperature of 200 degrees C was maintained for 1120 h with negligible resistance change of the heating wires after 900 h (heating wire resistance increased 0.2% over the final 220 h). The device is also subjected to 5700 thermal cycles between 55 and 195 degrees C, demonstrating reliability under thermal cycling.
NASA Technical Reports Server (NTRS)
Ngo, Quoc; Cruden, Brett A.; Cassell, Alan M.; Sims, Gerard; Li, Jun; Meyyappa, M.; Yang, Cary Y.
2005-01-01
Efforts in integrated circuit (IC) packaging technologies have recently been focused on management of increasing heat density associated with high frequency and high density circuit designs. While current flip-chip package designs can accommodate relatively high amounts of heat density, new materials need to be developed to manage thermal effects of next-generation integrated circuits. Multiwall carbon nanotubes (MWNT) have been shown to significantly enhance thermal conduction in the axial direction and thus can be considered to be a candidate for future thermal interface materials by facilitating efficient thermal transport. This work focuses on fabrication and characterization of a robust MWNT-copper composite material as an element in IC package designs. We show that using vertically aligned MWNT arrays reduces interfacial thermal resistance by increasing conduction surface area, and furthermore, the embedded copper acts as a lateral heat spreader to efficiently disperse heat, a necessary function for packaging materials. In addition, we demonstrate reusability of the material, and the absence of residue on the contacting material, both novel features of the MWNT-copper composite that are not found in most state-of-the-art thermal interface materials. Electrochemical methods such as metal deposition and etch are discussed for the creation of the MWNT-Cu composite, detailing issues and observations with using such methods. We show that precise engineering of the composite surface affects the ability of this material to act as an efficient thermal interface material. A thermal contact resistance measurement has been designed to obtain a value of thermal contact resistance for a variety of different thermal contact materials.
An initial investigation into methods of computing transonic aerodynamic sensitivity coefficients
NASA Technical Reports Server (NTRS)
Carlson, Leland A.
1991-01-01
The three dimensional quasi-analytical sensitivity analysis and the ancillary driver programs are developed needed to carry out the studies and perform comparisons. The code is essentially contained in one unified package which includes the following: (1) a three dimensional transonic wing analysis program (ZEBRA); (2) a quasi-analytical portion which determines the matrix elements in the quasi-analytical equations; (3) a method for computing the sensitivity coefficients from the resulting quasi-analytical equations; (4) a package to determine for comparison purposes sensitivity coefficients via the finite difference approach; and (5) a graphics package.
Effectiveness of X-ray grating interferometry for non-destructive inspection of packaged devices
NASA Astrophysics Data System (ADS)
Uehara, Masato; Yashiro, Wataru; Momose, Atsushi
2013-10-01
It is difficult to inspect packaged devices such as IC packages and power modules because the devices contain various components, such as semiconductors, metals, ceramics, and resin. In this paper, we demonstrated the effectiveness of X-ray grating interferometry (XGI) using a laboratory X-ray tube for the industrial inspection of packaged devices. The obtained conventional absorption image showed heavy-elemental components such as metal wires and electrodes, but the image did not reveal the defects in the light-elemental components. On the other hand, the differential phase-contrast image obtained by XGI revealed microvoids and scars in the encapsulant of the samples. The visibility contrast image also obtained by XGI showed some cracks in the ceramic insulator of power module sample. In addition, the image showed the silicon plate surrounded by the encapsulant having the same X-ray absorption coefficient. While these defects and components are invisible in the conventional industrial X-ray imaging, XGI thus has an attractive potential for the industrial inspection of the packaged devices.
Chen, Chang Hao; McCullagh, Elizabeth A.; Pun, Sio Hang; Mak, Peng Un; Vai, Mang I; Mak, Pui In; Klug, Achim; Lei, Tim C.
2017-01-01
The ability to record and to control action potential firing in neuronal circuits of the brain is critical to understand how the brain functions on the cellular and network levels. Recent development of optogenetic proteins allows direct stimulation or inhibition of action potential firing of neurons upon optical illumination. In this paper, we combined a low-noise and high input impedance (or low input capacitance) neural recording amplifier, and a high current laser/LED driver in a monolithic integrated circuit (IC) for simultaneous neural recording and optogenetic neural control. The low input capacitance of the amplifier (9.7 pF) was achieved through adding a dedicated unity gain input stage optimized for high impedance metal electrodes. The input referred noise of the amplifier was measured to be 4.57 µVrms, which is lower than the estimated thermal noise of the metal electrode. Thus, action potentials originating from a single neuron can be recorded with a signal-to-noise ratio of ~6.6. The LED/laser current driver delivers a maximum current of 330 mA to generate adequate light for optogenetic control. We experimentally tested the functionality of the IC with an anesthetized Mongolian gerbil and recorded auditory stimulated action potentials from the inferior colliculus. Furthermore, we showed that spontaneous firing of 5th (trigeminal) nerve fibers was inhibited using the optogenetic protein Halorhodopsin. A noise model was also derived including the equivalent electronic components of the metal electrode and the high current driver to guide the design. PMID:28221990
Vehicle Systems Engineering and Integration Activities - Phase 5
2012-08-31
and Engineering. Its objective is to fundamentally change the capabilities for the design, adaptation, and manufacture of defense systems. Recent...package. The standard RISE package includes an upgraded propulsion system ( turbocharged engine and new transmission), greatly improved driver...original M113A3 and M730A2 vehicles is the turbocharged 275 hp 6V53T engine from Detroit Diesel Corporation. Replacing the earlier 212 hp M113A2
ERIC Educational Resources Information Center
Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.
2012-01-01
In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling…
INCREASING FOLLOWING HEADWAY WITH PROMPTS, GOAL SETTING, AND FEEDBACK IN A DRIVING SIMULATOR
Arnold, Michelle L; Van Houten, Ron
2011-01-01
We evaluated the effects of prompting, goal setting, and feedback on following headway of young drivers in a simulated driving environment and assessed whether changes produced in following headway were associated with reductions in hard braking when drivers were and were not using cell phones. Participants were 4 university students. During baseline, drivers spent half of the time talking on cell phones while driving. At the start of the intervention, drivers were prompted to increase following headway while on the cell phones and were provided a specific target for following headway. Drivers were given feedback on increasing following headway when on cell phones at the end of each session. The intervention package was associated with an increase in following headway and a decrease in hard braking when participants were on and off the cell phones. Cell phone use did not affect any of the measures. PMID:21709782
Merging parallel optics packaging and surface mount technologies
NASA Astrophysics Data System (ADS)
Kopp, Christophe; Volpert, Marion; Routin, Julien; Bernabé, Stéphane; Rossat, Cyrille; Tournaire, Myriam; Hamelin, Régis
2008-02-01
Optical links are well known to present significant advantages over electrical links for very high-speed data rate at 10Gpbs and above per channel. However, the transition towards optical interconnects solutions for short and very short reach applications requires the development of innovative packaging solutions that would deal with very high volume production capability and very low cost per unit. Moreover, the optoelectronic transceiver components must be able to move from the edge to anywhere on the printed circuit board, for instance close to integrated circuits with high speed IO. In this paper, we present an original packaging design to manufacture parallel optic transceivers that are surface mount devices. The package combines highly integrated Multi-Chip-Module on glass and usual IC ceramics packaging. The use of ceramic and the development of sealing technologies achieve hermetic requirements. Moreover, thanks to a chip scale package approach the final device exhibits a much minimized footprint. One of the main advantages of the package is its flexibility to be soldered or plugged anywhere on the printed circuit board as any other electronic device. As a demonstrator we present a 2 by 4 10Gbps transceiver operating at 850nm.
Robust, High-Speed Network Design for Large-Scale Multiprocessing
1993-09-01
3.17 Left: Non-expansive Wiring of Processors to First Stage Routing Elements . ... 38 3.18 Right: Expansive Wiring of Processors to First Stage...162 8.2 RNI Micro -architecture ........ .............................. 163 8.3 Packaged RN I IC...169 11.1 MLUNK Message Formats ........ .............................. 173 12.1 Routing Board Arrangement for 64- processor Machine
Mazloumi, Adel; Mohammadreze, Fallah
2012-01-01
One of the applications of ergonomics disciplinary is designing driver workstation compatible to users' characteristics. The aim of this study was evaluation of interior design of Shoka vehicle with respect to the accommodation for Iranian population and proposing suggestions for customizing design of this vehicle. This study was a descriptive-analytical study conducted among thirty men from Iranian drivers population in 5, 50, 95 percentiles of the stature variable. Objective variables related to the occupant packaging and vehicle visual aspects including anthropometric variables, frontal, lateral, and side view and so on were investigated first. Then, subjective variables related to the driver mental workload and body comfort discomfort were studied using BMDMW and comfort questionnaires during 2-hour driving trial sessions. Occupant packaging variables and hand-arm angle showed the least accommodation percent (%53). Seating angles showed low accommodation as well (%73). Among three percentile groups there were no significant differences between the mean values of mental workload during two hours driving task. And, the mean value related to the comfort discomfort was 3.9 during driving sessions. Considering the findings in this study, it can be conclude that seating angles need correction and optimization. Taking mental workload results into account, it can be concluded that the interior design of the studied car had no influence on drivers' mental workload. From the aspect of comfort discomfort, Shoka vehicle showed neutral state among drivers. Optimizing seating angles, decreasing vibration, correcting stiffness of seating pan are suggested for customization of the ergonomics aspect of this vehicle.
Evaluation of four steering wheels to determine driver hand placement in a static environment.
Mossey, Mary E; Xi, Yubin; McConomy, Shayne K; Brooks, Johnell O; Rosopa, Patrick J; Venhovens, Paul J
2014-07-01
While much research exists on occupant packaging both proprietary and in the literature, more detailed research regarding user preferences for subjective ratings of steering wheel designs is sparse in published literature. This study aimed to explore the driver interactions with production steering wheels in four vehicles by using anthropometric data, driver hand placement, and driver grip design preferences for Generation-Y and Baby Boomers. In this study, participants selected their preferred grip diameter, responded to a series of questions about the steering wheel grip as they sat in four vehicles, and rank ordered their preferred grip design. Thirty-two male participants (16 Baby Boomers between ages 47 and 65 and 16 Generation-Y between ages 18 and 29) participated in the study. Drivers demonstrated different gripping behavior between vehicles and between groups. Recommendations for future work in steering wheel grip design and naturalistic driver hand positioning are discussed. Copyright © 2014. Published by Elsevier Ltd.
Automotive Stirling engine development program
NASA Technical Reports Server (NTRS)
Ernst, W.; Richey, A.; Farrell, R.; Riecke, G.; Smith, G.; Howarth, R.; Cronin, M.; Simetkosky, M.; Meacher, J.
1986-01-01
The major accomplishments were the completion of the Basic Stirling Engine (BSE) and the Stirling Engine System (SES) designs on schedule, the approval and acceptance of those designs by NASA, and the initiation of manufacture of BSE components. The performance predictions indicate the Mod II engine design will meet or exceed the original program goals of 30% improvement in fuel economy over a conventional Internal Combustion (IC) powered vehicle, while providing acceptable emissions. This was accomplished while simultaneously reducing Mod II engine weight to a level comparable with IC engine power density, and packaging the Mod II in a 1985 Celebrity with no external sheet metal changes. The projected mileage of the Mod II Celebrity for the combined urban and highway CVS cycle is 40.9 mpg which is a 32% improvement over the IC Celebrity. If additional potential improvements are verified and incorporated in the Mod II, the mileage could increase to 42.7 mpg.
NASA Astrophysics Data System (ADS)
Chang, Chun-Yen; Trappey, Charles V.
2003-06-01
Taiwan's electronics industry emerged in the 1960s with the creation of a small but well planned integrated circuit (IC) packaging industry. This industry investment led to bolder investments in research, laboratories, and the island's first semiconductor foundries in the 1980s. Following the success of the emerging IC manufacturers and design houses, hundreds of service firms and related industries (software, legal services, substrate, chemical, and test firms among others) opened for business and completed Taiwan's IC manufacturing supply chain. The challenge for Taiwan's electronics industry is to take the lead in the design, manufacture, and marketing of name brand electronic products. This paper introduces the Si-Soft (silicon software) Project, a national initiative that builds on Taiwan's achievements in manufacturing (referred to as Si-Hard or silicon hardware) to launch a new wave of companies. These firms will contribute to the core underlying technology (intellectual property) used in the creation of electronic products.
Graham, Anthony H. D.; Robbins, Jon; Bowen, Chris R.; Taylor, John
2011-01-01
The adaptation of standard integrated circuit (IC) technology as a transducer in cell-based biosensors in drug discovery pharmacology, neural interface systems and electrophysiology requires electrodes that are electrochemically stable, biocompatible and affordable. Unfortunately, the ubiquitous Complementary Metal Oxide Semiconductor (CMOS) IC technology does not meet the first of these requirements. For devices intended only for research, modification of CMOS by post-processing using cleanroom facilities has been achieved. However, to enable adoption of CMOS as a basis for commercial biosensors, the economies of scale of CMOS fabrication must be maintained by using only low-cost post-processing techniques. This review highlights the methodologies employed in cell-based biosensor design where CMOS-based integrated circuits (ICs) form an integral part of the transducer system. Particular emphasis will be placed on the application of multi-electrode arrays for in vitro neuroscience applications. Identifying suitable IC packaging methods presents further significant challenges when considering specific applications. The various challenges and difficulties are reviewed and some potential solutions are presented. PMID:22163884
Training program for driver licensing screening for medical impairment
DOT National Transportation Integrated Search
1977-08-01
The purpose of the contract was to create a complete curriculum package, for training motor vehicle license examiners to identify individuals with potentially unsafe physical or mental conditions. The present report describes the process followed in ...
VCSEL-based optical transceiver module operating at 25 Gb/s and using a single CMOS IC
NASA Astrophysics Data System (ADS)
Afriat, Gil; Horwitz, Lior; Lazar, Dror; Issachar, Assaf; Pogrebinsky, Alexander; Ran, Adee; Shoor, Ehud; Bar, Roi; Saba, Rushdy
2012-01-01
We present here a low cost, small form factor, optical transceiver module composed of a CMOS IC transceiver, 850 nm emission wavelength VCSEL modulated at 25 Gb/s, and an InGaAs/InP PIN Photo Diode (PD). The transceiver IC is fabricated in a standard 28 nm CMOS process and integrates the analog circuits interfacing the VCSEL and PD, namely the VCSEL driver and Transimpedance Amplifier (TIA), as well as all other required transmitter and receiver circuits like Phase Locked Loop (PLL), Post Amplifier and Clock & Data Recovery (CDR). The transceiver module couples into a 62.5/125 um multi-mode (OM1) TX/RX fiber pair via a low cost plastic cover realizing the transmitter and receiver lens systems and demonstrates BER < 10-12 at the 25 Gb/s data rate over a distance of 3 meters. Using a 50/125 um laser optimized multi-mode fiber (OM3), the same performance was achieved over a distance of 30 meters.
AIN-Based Packaging for SiC High-Temperature Electronics
NASA Technical Reports Server (NTRS)
Savrun, Ender
2004-01-01
Packaging made primarily of aluminum nitride has been developed to enclose silicon carbide-based integrated circuits (ICs), including circuits containing SiC-based power diodes, that are capable of operation under conditions more severe than can be withstood by silicon-based integrated circuits. A major objective of this development was to enable packaged SiC electronic circuits to operate continuously at temperatures up to 500 C. AlN-packaged SiC electronic circuits have commercial potential for incorporation into high-power electronic equipment and into sensors that must withstand high temperatures and/or high pressures in diverse applications that include exploration in outer space, well logging, and monitoring of nuclear power systems. This packaging embodies concepts drawn from flip-chip packaging of silicon-based integrated circuits. One or more SiC-based circuit chips are mounted on an aluminum nitride package substrate or sandwiched between two such substrates. Intimate electrical connections between metal conductors on the chip(s) and the metal conductors on external circuits are made by direct bonding to interconnections on the package substrate(s) and/or by use of holes through the package substrate(s). This approach eliminates the need for wire bonds, which have been the most vulnerable links in conventional electronic circuitry in hostile environments. Moreover, the elimination of wire bonds makes it possible to pack chips more densely than was previously possible.
Preliminary design approach for large high precision segmented reflectors
NASA Technical Reports Server (NTRS)
Mikulas, Martin M., Jr.; Collins, Timothy J.; Hedgepeth, John M.
1990-01-01
A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.
4H-SiC JFET Multilayer Integrated Circuit Technologies Tested Up to 1000 K
NASA Technical Reports Server (NTRS)
Spry, D. J.; Neudeck, P. G.; Chen, L.; Chang, C. W.; Lukco, D.; Beheim, G. M.
2015-01-01
Testing of semiconductor electronics at temperatures above their designed operating envelope is recognized as vital to qualification and lifetime prediction of circuits. This work describes the high temperature electrical testing of prototype 4H silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) technology implemented with multilayer interconnects; these ICs are intended for prolonged operation at temperatures up to 773K (500 C). A 50 mm diameter sapphire wafer was used in place of the standard NASA packaging for this experiment. Testing was carried out between 300K (27 C) and 1150K (877 C) with successful electrical operation of all devices observed up to 1000K (727 C).
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2015-01-01
Complex integrated circuit (IC) chips rely on more than one level of interconnect metallization for routing of electrical power and signals. This work reports the processing and testing of 4H-SiC junction field effect transistor (JFET) prototype ICs with two levels of metal interconnect capable of prolonged operation at 500 C. Packaged functional circuits including 3-and 11-stage ring oscillators, a 4-bit digital to analog converter, and a 4-bit address decoder and random access memory cell have been demonstrated at 500 C. A 3-stage oscillator functioned for over 3000 hours at 500 C in air ambient.
Iterative categorization (IC): a systematic technique for analysing qualitative data
2016-01-01
Abstract The processes of analysing qualitative data, particularly the stage between coding and publication, are often vague and/or poorly explained within addiction science and research more broadly. A simple but rigorous and transparent technique for analysing qualitative textual data, developed within the field of addiction, is described. The technique, iterative categorization (IC), is suitable for use with inductive and deductive codes and can support a range of common analytical approaches, e.g. thematic analysis, Framework, constant comparison, analytical induction, content analysis, conversational analysis, discourse analysis, interpretative phenomenological analysis and narrative analysis. Once the data have been coded, the only software required is a standard word processing package. Worked examples are provided. PMID:26806155
NASA Astrophysics Data System (ADS)
Brusberg, Lars; Lang, Günter; Schröder, Henning
2011-01-01
The proposed novel packaging approach merges micro-system packaging and glass integrated optics. It provides 3D optical single-mode intra system links to bridge the gap between novel photonic integrated circuits and the glass fibers for inter system interconnects. We introduce our hybrid 3D photonic packaging approach based on thin glass substrates with planar integrated optical single-mode waveguides for fiber-to-chip and chip-to-chip links. Optical mirrors and lenses provide optical mode matching for photonic IC assemblies and optical fiber interconnects. Thin glass is commercially available in panel and wafer formats and characterizes excellent optical and high-frequency properties as reviewed in the paper. That makes it perfect for micro-system packaging. The adopted planar waveguide process based on ion-exchange technology is capable for high-volume manufacturing. This ion-exchange process and the optical propagation are described in detail for thin glass substrates. An extensive characterization of all basic circuit elements like straight and curved waveguides, couplers and crosses proves the low attenuation of the optical circuit elements.
Chalmers, James D; Poole, Chris; Webster, Samantha; Tebboth, Abigail; Dickinson, Scott; Gayle, Alicia
2018-04-11
Recent recommendations from the Global Initiative for Chronic Obstructive Lung Disease (GOLD) position inhaled corticosteroids (ICS) for use in chronic obstructive pulmonary disease (COPD) patients experiencing exacerbations (≥ 2 or ≥ 1 requiring hospitalisation); i.e. GOLD groups C and D. However, it is known that ICS is frequently prescribed for patients with less severe COPD. Potential drivers of inappropriate ICS use may be historical clinical guidance or a belief among physicians that intervening early with ICS would improve outcomes and reduce resource use. The objective of this study was to compare healthcare resource use in the UK for COPD patients in GOLD groups A and B (0 or 1 exacerbation not resulting in hospitalisation) who have either been prescribed an ICS-containing regimen or a non-ICS-containing regimen. Linked data from the Clinical Practice Research Datalink (CPRD) and Hospital Episode Statistics (HES) database were used. For the study period (1 July 2005 to 30 June 2015) a total 4009 patients met the inclusion criteria; 1745 receiving ICS-containing therapy and 2264 receiving non-ICS therapy. Treatment groups were propensity score-matched to account for potential confounders in the decision to prescribe ICS, leaving 1739 patients in both treatment arms. Resource use was assessed in terms of frequency of healthcare practitioner (HCP) interactions and rescue therapy prescribing. Treatment acquisition costs were not assessed. Results showed no benefit associated with the addition of ICS, with numerically higher all-cause HCP interactions (72,802 versus 69,136; adjusted relative rate: 1.07 [p = 0.061]) and rescue therapy prescriptions (24,063 versus 21,163; adjusted relative rate: 1.05 [p = 0.212]) for the ICS-containing group compared to the non-ICS group. Rate ratios favoured the non-ICS group for eight of nine outcomes assessed. Outcomes were similar for subgroup analyses surrounding potential influential parameters, including patients with poorer lung function (FEV 1 < 50% predicted), one prior exacerbation or elevated blood eosinophils. These data suggest that ICS use in GOLD A and B COPD patients is not associated with a benefit in terms of healthcare resource use compared to non-ICS bronchodilator-based therapy; using ICS according to GOLD recommendations may offer an opportunity for improving patient care and reducing resource use.
Packaging of MEMS/MOEMS and nanodevices: reliability, testing, and characterization aspects
NASA Astrophysics Data System (ADS)
Tekin, Tolga; Ngo, Ha-Duong; Wittler, Olaf; Bouhlal, Bouchaib; Lang, Klaus-Dieter
2011-02-01
The last decade witnessed an explosive growth in research and development efforts devoted to MEMS devices and packaging. The successfully developed MEMS devices are, for example inkjet, pressure sensors, silicon microphones, accelerometers, gyroscopes, MOEMS, micro fuel cells and emerging MEMS. For the next decade, MEMS/MOEMS and nanodevice based products will penetrate into IT, telecommunications, automotive, defense, life sciences, medical and implantable applications. Forecasts say the MEMS market to be $14 billion by 2012. The packaging cost of MEMS/MOEMS products in general is about 70 percent. Unlike today's electronics IC packaging, their packaging are custom-built and difficult due to the moving structural elements. In order for the moving elements of a MEMS device to move effectively in a well-controlled atmosphere, hermetic sealing of the MEMS device in a cap is necessary. For some MEMS devices, such as resonators and gyroscopes, vacuum packaging is required. Usually, the cap is processed at the wafer level, and thus MEMS packaging is truly a wafer level packaging. In terms of MEMS/MOEMS and nanodevice packaging, there are still many critical issues need to be addressed due to the increasing integration density supported by 3D heterogeneous integration of multi-physic components/layers consisting of photonics, electronics, rf, plasmonics, and wireless. The infrastructure of MEMS/MOEMS and nanodevices and their packaging is not well established yet. Generic packaging platform technologies are not available. Some of critical issues have been studied intensively in the last years. In this paper we will discuss about processes, reliability, testing and characterization of MEMS/MOEMS and nanodevice packaging.
77 FR 31815 - Hazardous Materials Regulations: Combustible Liquids
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... are: Safety (hazard communication and packaging integrity); International commerce (frustration/delay... exempt seasonal workers from the Federal Motor Carrier Safety Administration's Commercial Driver's...: Anyone is able to search the electronic form of any written communications and comments received into any...
Molding compound trends in a denser packaging world: Qualification tests and reliability concerns
NASA Astrophysics Data System (ADS)
Nguyen, L. T.; Lo, R. H. Y.; Chen, A. S.; Belani, J. G.
1993-12-01
Molding compound development has traditionally been driven by the memory market, then subsequent applications filter down to other IC technologies such as logic, analog, and ASIC. However, this strategy has changed lately with the introduction of thin packages such as PQFP & TSOP. Rather than targeting a compound for a family of IC such as DRAM or SRAM, compound development efforts are now focused at specific classes of packages. The configurations of these thin packages impose new functional requirements that need to be revisited to provide the optimized combination of properties. The evolution of qualification tests mirrors the advances in epoxy and compounding technologies. From the first standard novolac-based epoxies of the 1970s to the latest 3(sup rd)-generation ultra-low stress materials, longer test times at increasingly harsher environments were achieved. This paper benchmarks the current reliability tests used by the electronic industry, examines those tests that affect and are affected by the molding compounds, discusses the relevance of accelerated testing, and addresses the major reliability issues facing current molding compound development efforts. Six compound-related reliability concerns were selected: moldability, package stresses, package cracking, halogen-induced intermetallic growth at bond pads, moisture-induced corrosion, and interfacial delamination. Causes of each failure type are surveyed and remedies are recommended. Accelerated tests are designed to apply to a limited quantity of devices, bias, or environmental conditions larger than usual ratings, to intensify failure mechanisms that would occur under normal operating conditions. The observed behavior is then extrapolated from the lot to the entire population. Emphasis is on compressing the time necessary to obtain reliability data. This approach has two main drawbacks. With increasingly complex devices, even accelerated tests are expensive. And with new technologies, it becomes difficult to ascertain that the applied stress 1) induces the failure phenomenon linked with usual field conditions, and 2) does not create any new ones. Technology evolution and reliability testing are interdependent. Devices get larger with increasingly smaller features and more complex geometries. Molding compounds have evolved considerably over the past decade to provide ultra-low stress levels and moldability for thin packages.
TDR method for determine IC's parameters
NASA Astrophysics Data System (ADS)
Timoshenkov, V.; Rodionov, D.; Khlybov, A.
2016-12-01
Frequency domain simulation is a widely used approach for determine integrated circuits parameters. This approach can be found in most of software tools used in IC industry. Time domain simulation approach shows intensive usage last years due to some advantages. In particular it applicable for analysis of nonlinear and nonstationary systems where frequency domain is inapplicable. Resolution of time domain systems allow see heterogeneities on distance 1mm, determine it parameters and properties. Authors used approach based on detecting reflected signals from heterogeneities - time domain reflectometry (TDR). Field effect transistor technology scaling up to 30-60nm gate length and 10nm gate dielectric, heterojunction bi-polar transistors with 10-30nm base width allows fabricate digital IC's with 20GHz clock frequency and RF-IC's with tens GHz bandwidth. Such devices and operation speed suppose transit signal by use microwave lines. There are local heterogeneities can be found inside of the signal path due to connections between different parts of signal lines (stripe line-RF-connector pin, stripe line - IC package pin). These heterogeneities distort signals that cause bandwidth decrease for RF-devices. Time domain research methods of transmission and reflected signals give the opportunities to determine heterogeneities, it properties, parameters and built up equivalent circuits. Experimental results are provided and show possibility for inductance and capacitance measurement up to 25GHz. Measurements contains result of signal path research on IC and printed circuit board (PCB) used for 12GHz RF chips. Also dielectric constant versus frequency was measured up to 35GHz.
A brief office-based hazard perception intervention for drivers with ADHD symptoms.
Poulsen, Anne A; Horswill, Mark S; Wetton, Mark A; Hill, Andrew; Lim, Sok Mui
2010-06-01
The aim of this study was to develop a simple and brief hazard perception training intervention tailored to meet the needs of male drivers with attention-deficit-hyperactivity disorder symptoms. Twenty male drivers with attention-deficit-hyperactivity disorder symptoms were quasi-randomly assigned to either a hazard perception training package (trained group) or a control intervention video (untrained group), presented in an office setting. Video-based hazard perception tests involving real-life driving scenes were conducted both before and after the interventions. The hazard perception response times of the trained group significantly improved compared with the untrained group, t (18) = 3.21, p < 0.005. Significant improvements in hazard perception response times in male drivers with attention-deficit-hyperactivity disorder symptoms were found following the training intervention. This indicates that such training has potential for inclusion in a management plan for reducing the crash rates of this high risk group of drivers. The training is practical, quick, and affordable, and has the potential to translate into real-world driving outcomes.
MEMS (Micro-Electro-Mechanical Systems) for Automotive and Consumer Electronics
NASA Astrophysics Data System (ADS)
Marek, Jiri; Gómez, Udo-Martin
MEMS sensors gained over the last two decades an impressive width of applications: (a) ESP: A car is skidding and stabilizes itself without driver intervention (b) Free-fall detection: A laptop falls to the floor and protects the hard drive by parking the read/write drive head automatically before impact. (c) Airbag: An airbag fires before the driver/occupant involved in an impending automotive crash impacts the steering wheel, thereby significantly reducing physical injury risk. MEMS sensors are sensing the environmental conditions and are giving input to electronic control systems. These crucial MEMS sensors are making system reactions to human needs more intelligent, precise, and at much faster reaction rates than humanly possible. Important prerequisites for the success of sensors are their size, functionality, power consumption, and costs. This technical progress in sensor development is realized by micro-machining. The development of these processes was the breakthrough to industrial mass-production for micro-electro-mechanical systems (MEMS). Besides leading-edge micromechanical processes, innovative and robust ASIC designs, thorough simulations of the electrical and mechanical behaviour, a deep understanding of the interactions (mainly over temperature and lifetime) of the package and the mechanical structures are needed. This was achieved over the last 20 years by intense and successful development activities combined with the experience of volume production of billions of sensors. This chapter gives an overview of current MEMS technology, its applications and the market share. The MEMS processes are described, and the challenges of MEMS, compared to standard IC fabrication, are discussed. The evolution of MEMS requirements is presented, and a short survey of MEMS applications is shown. Concepts of newest inertial sensors for ESP-systems are given with an emphasis on the design concepts of the sensing element and the evaluation circuit for achieving excellent noise performance. The chapter concludes with an outlook on arising new MEMS applications such as energy harvester and micro fuel cells.
High Volume Manufacturing and Field Stability of MEMS Products
NASA Astrophysics Data System (ADS)
Martin, Jack
Low volume MEMS/NEMS production is practical when an attractive concept is implemented with business, manufacturing, packaging, and test support. Moving beyond this to high volume production adds requirements on design, process control, quality, product stability, market size, market maturity, capital investment, and business systems. In a broad sense, this chapter uses a case study approach: It describes and compares the silicon-based MEMS accelerometers, pressure sensors, image projection systems, and gyroscopes that are in high volume production. Although they serve several markets, these businesses have common characteristics. For example, the manufacturing lines use automated semiconductor equipment and standard material sets to make consistent products in large quantities. Standard, well controlled processes are sometimes modified for a MEMS product. However, novel processes that cannot run with standard equipment and material sets are avoided when possible. This reliance on semiconductor tools, as well as the organizational practices required to manufacture clean, particle-free products partially explains why the MEMS market leaders are integrated circuit manufacturers. There are other factors. MEMS and NEMS are enabling technologies, so it can take several years for high volume applications to develop. Indeed, market size is usually a strong function of price. This becomes a vicious circle, because low price requires low cost - a result that is normally achieved only after a product is in high volume production. During the early years, IC companies reduced cost and financial risk by using existing facilities for low volume MEMS production. As a result, product architectures are partially determined by capabilities developed for previous products. This chapter includes a discussion of MEMS product architecture with particular attention to the impact of electronic integration, packaging, and surfaces. Packaging and testing are critical, because they are significant factors in MEMS product cost. These devices have extremelyhigh surface/volume ratios, so performance and stability may depend on the control of surface characteristics after packaging. Looking into the future, the competitive advantage of IC suppliers will decrease as small companies learn to integrate MEMS/NEMS devices on CMOS foundry wafers. Packaging challenges still remain, because most MEMS/NEMS products must interact with the environment without degrading stability or reliability. Generic packaging solutions are unlikely. However, packaging subcontractors recognize that MEMS/NEMS is a growth opportunity. They will spread the overhead burden of high-capital-cost-facilities by developing flexible processes in order to package several types of moderate volume integrated MEMS/NEMS products on the same equipment.
High Volume Manufacturing and Field Stability of MEMS Products
NASA Astrophysics Data System (ADS)
Martin, Jack
Low volume MEMS/NEMS production is practical when an attractive concept is implemented with business, manufacturing, packaging, and test support. Moving beyond this to high volume production adds requirements on design, process control, quality, product stability, market size, market maturity, capital investment, and business systems. In a broad sense, this chapter uses a case study approach: It describes and compares the silicon-based MEMS accelerometers, pressure sensors, image projection systems, and gyroscopes that are in high volume production. Although they serve several markets, these businesses have common characteristics. For example, the manufacturing lines use automated semiconductor equipment and standard material sets to make consistent products in large quantities. Standard, well controlled processes are sometimes modified for a MEMS product. However, novel processes that cannot run with standard equipment and material sets are avoided when possible. This reliance on semiconductor tools, as well as the organizational practices required to manufacture clean, particle-free products partially explains why the MEMS market leaders are integrated circuit manufacturers. There are other factors. MEMS and NEMS are enabling technologies, so it can take several years for high volume applications to develop. Indeed, market size is usually a strong function of price. This becomes a vicious circle, because low price requires low cost - a result that is normally achieved only after a product is in high volume production. During the early years, IC companies reduced cost and financial risk by using existing facilities for low volume MEMS production. As a result, product architectures are partially determined by capabilities developed for previous products. This chapter includes a discussion of MEMS product architecture with particular attention to the impact of electronic integration, packaging, and surfaces. Packaging and testing are critical, because they are significant factors in MEMS product cost. These devices have extremely high surface/volume ratios, so performance and stability may depend on the control of surface characteristics after packaging. Looking into the future, the competitive advantage of IC suppliers will decrease as small companies learn to integrate MEMS/NEMS devices on CMOS foundry wafers. Packaging challenges still remain, because most MEMS/NEMS products must interact with the environment without degrading stability or reliability. Generic packaging solutions are unlikely. However, packaging subcontractors recognize that MEMS/NEMS is a growth opportunity. They will spread the overhead burden of high-capital-cost-facilities by developing flexible processes in order to package several types of moderate volume integrated MEMS/NEMS products on the same equipment.
NASA Astrophysics Data System (ADS)
Hoffmann, T. L.; Lauterjung, J.
2017-12-01
The European Plate Observing System project is currently approaching the end of year two of its four-year Implementation Phase 2015-18 (EPOS-IP). Under the Horizon 2020 Programme INFRADEV-3, the EPOS cyberinfrastructure is being established as an ERIC (European Research Infrastructure Consortium) and encompasses the implementation of both the EPOS Integrated Core Services (ICS) for solid Earth Science and a multitude of EPOS Thematic Core Services (TCS). During year two, a basic set of ICS and TCS services was developed and implemented, so that in October 2017 the validation phase (year 3) of EPOS is ready to be launched. Up to now, various TCS-Elements have integrated different Service Providers (SD) that are delivering Data, Data Products, Services and Software (DDSS) to their specific scientific community. As one of the 29 awardees of the EC grant, the German Research Center for Geosciences (GFZ) plays an important role in the implementation of EPOS and its Thematic and Integrated Core Services. The presented poster will give an overview of GFZ's participation in the work of nine technical EPOS Work Packages (WP7 ICS Development, WP8 Seismology, WP11 Volcano Observations, WP12 Satellite Data, WP13 Geomagnetic Observations, WP14 Anthropogenic Hazards, WP15 Geological Information and Modelling, WP16 Multi-Scale Laboratories and WP17 Geo Energy Test Beds) as well as in four administrative EPOS Work Packages (WP2 Communication, WP3 Harmonization, WP4 Legal & Governance, and WP5 Financial).
Preliminary design considerations for 10 to 40 meter-diameter precision truss reflectors
NASA Technical Reports Server (NTRS)
Mikulas, Martin M., Jr.; Collins, Timothy J.; Hedgepeth, John M.
1990-01-01
A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.
Hertel, Nadine; Kotchie, Robert W; Samyshkin, Yevgeniy; Radford, Matthew; Humphreys, Samantha; Jameson, Kevin
2012-01-01
Frequent exacerbations which are both costly and potentially life-threatening are a major concern to patients with chronic obstructive pulmonary disease (COPD), despite the availability of several treatment options. This study aimed to assess the lifetime costs and outcomes associated with alternative treatment regimens for patients with severe COPD in the UK setting. A Markov cohort model was developed to predict lifetime costs, outcomes, and cost-effectiveness of various combinations of a long-acting muscarinic antagonist (LAMA), a long-acting beta agonist (LABA), an inhaled corticosteroid (ICS), and roflumilast in a fully incremental analysis. Patients willing and able to take ICS, and those refusing or intolerant to ICS were analyzed separately. Efficacy was expressed as relative rate ratios of COPD exacerbation associated with alternative treatment regimens, taken from a mixed treatment comparison. The analysis was conducted from the UK National Health Service (NHS) perspective. Parameter uncertainty was explored using one-way and probabilistic sensitivity analysis. Based on the results of the fully incremental analysis a cost-effectiveness frontier was determined, indicating those treatment regimens which represent the most cost-effective use of NHS resources. For ICS-tolerant patients the cost-effectiveness frontier suggested LAMA as initial treatment. Where patients continue to exacerbate and additional therapy is required, LAMA + LABA/ICS can be a cost-effective option, followed by LAMA + LABA/ICS + roflumilast (incremental cost-effectiveness ratio [ICER] versus LAMA + LABA/ICS: £16,566 per quality-adjusted life-year [QALY] gained). The ICER in ICS-intolerant patients, comparing LAMA + LABA + roflumilast versus LAMA + LABA, was £13,764/QALY gained. The relative rate ratio of exacerbations was identified as the primary driver of cost-effectiveness. The treatment algorithm recommended in UK clinical practice represents a cost-effective approach for the management of COPD. The addition of roflumilast to the standard of care regimens is a clinical and cost-effective treatment option for patients with severe COPD, who continue to exacerbate despite existing bronchodilator therapy.
The next generation in optical transport semiconductors: IC solutions at the system level
NASA Astrophysics Data System (ADS)
Gomatam, Badri N.
2005-02-01
In this tutorial overview, we survey some of the challenging problems facing Optical Transport and their solutions using new semiconductor-based technologies. Advances in 0.13um CMOS, SiGe/HBT and InP/HBT IC process technologies and mixed-signal design strategies are the fundamental breakthroughs that have made these solutions possible. In combination with innovative packaging and transponder/transceiver architectures IC approaches have clearly demonstrated enhanced optical link budgets with simultaneously lower (perhaps the lowest to date) cost and manufacturability tradeoffs. This paper will describe: *Electronic Dispersion Compensation broadly viewed as the overcoming of dispersion based limits to OC-192 links and extending link budgets, *Error Control/Coding also known as Forward Error Correction (FEC), *Adaptive Receivers for signal quality monitoring for real-time estimation of Q/OSNR, eye-pattern, signal BER and related temporal statistics (such as jitter). We will discuss the theoretical underpinnings of these receiver and transmitter architectures, provide examples of system performance and conclude with general market trends. These Physical layer IC solutions represent a fundamental new toolbox of options for equipment designers in addressing systems level problems. With unmatched cost and yield/performance tradeoffs, it is expected that IC approaches will provide significant flexibility in turn, for carriers and service providers who must ultimately manage the network and assure acceptable quality of service under stringent cost constraints.
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2015-01-01
Complex integrated circuit (IC) chips rely on more than one level of interconnect metallization for routing of electrical power and signals. This work reports the processing and testing of 4H-SiC junction field effect transistor (JFET) prototype IC's with two levels of metal interconnect capable of prolonged operation at 500 C. Packaged functional circuits including 3- and 11-stage ring oscillators, a 4-bit digital to analog converter, and a 4-bit address decoder and random access memory cell have been demonstrated at 500 C. A 3-stage oscillator functioned for over 3000 hours at 500 C in air ambient. Improved reproducibility remains to be accomplished.
Prolonged 500 C Operation of 100+ Transistor Silicon Carbide Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Lukco, Dorothy; Chen, Liangyu; Krasowski, Michael J.; Prokop, Norman F.; Chang, Carl W.; Beheim, Glenn M.
2017-01-01
This report describes more than 5000 hours of successful 500 C operation of semiconductor integrated circuits (ICs) with more than 100 transistors. Multiple packaged chips with two different 4H-SiC junction field effect transistor (JFET) technology demonstrator circuits have surpassed thousands of hours of oven-testing at 500 C. After 100 hours of 500 C burn-in, the circuits (except for 2 failures) exhibit less than 10% change in output characteristics for the remainder of 500 C testing. We also describe the observation of important differences in IC materials durability when subjected to the first nine constituents of Venus-surface atmosphere at 9.4 MPa and 460 C in comparison to what is observed for Earth-atmosphere oven testing at 500 C.
Prolonged 500 C Operation of 100+ Transistor Silicon Carbide Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Lukco, Dorothy; Chen, Liangyu; Krasowski, Michael J.; Prokop, Norman F.; Chang, Carl W.; Beheim, Glenn M.
2017-01-01
This report describes more than 5000 hours of successful 500 C operation of semiconductor integrated circuits (ICs) with more than 100 transistors. Multiple packaged chips with two different 4H-SiC junction field effect transistor (JFET) technology demonstrator circuits have surpassed thousands of hours of oven-testing at 500 C. After 100 hours of 500 C burn-in, the circuits (except for 2 failures) exhibit less than 10 change in output characteristics for the remainder of 500C testing. We also describe the observation of important differences in IC materials durability when subjected to the first nine constituents of Venus-surface atmosphere at 9.4 MPa and 460C in comparison to what is observed for Earth-atmosphere oven testing at 500 C.
A proposed holistic approach to on-chip, off-chip, test, and package interconnections
NASA Astrophysics Data System (ADS)
Bartelink, Dirk J.
1998-11-01
The term interconnection has traditionally implied a `robust' connection from a transistor or a group of transistors in an IC to the outside world, usually a PC board. Optimum system utilization is done from outside the IC. As an alternative, this paper addresses `unimpeded' transistor-to-transistor interconnection aimed at reaching the high circuit densities and computational capabilities of neighboring IC's. In this view, interconnections are not made to some human-centric place outside the IC world requiring robustness—except for system input and output connections. This unimpeded interconnect style is currently available only through intra-chip signal traces in `system-on-a-chip' implementations, as exemplified by embedded DRAMs. Because the traditional off-chip penalty in performance and wiring density is so large, a merging of complex process technologies is the only option today. It is suggested that, for system integration to move forward, the traditional robustness requirement inherited from conventional packaging interconnect and IC manufacturing test must be discarded. Traditional system assembly from vendor parts requires robustness under shipping, inspection and assembly. The trend toward systems on a chip signifies willingness by semiconductor companies to design and fabricate whole systems in house, so that `in-house' chip-to-chip assembly is not beyond reach. In this scenario, bare chips never leave the controlled environment of the IC fabricator while the two major contributors to off-chip signal penalty, ESD protection and the need to source a 50-ohm test head, are avoided. With in-house assembly, ESD protection can be eliminated with the precautions already familiar in plasma etching. Test interconnection impacts the fundamentals of IC manufacturing, particularly with clock speeds approaching 1GHz, and cannot be an afterthought. It should be an integral part of the chip-to-chip interconnection bandwidth optimization, because—as we must recognize—test is also performed using IC's. A system interconnection is proposed using multiple chips fabricated with conventional silicon processes, including MEMS technology. The system resembles an MCM that can be joined without committing to final assembly to perform at-speed testing. 50-Ohm test probes never load the circuit; only intended neighboring chips are ever connected. A `back-plane' chip provides the connection layers for both inter- and intra-chip signals and also serves as the probe card, in analogy with membrane probes now used for single-chip testing. Intra-chip connections, which require complicated connections during test that exactly match the product, are then properly made and all waveforms and loading conditions under test will be identical to those of the product. The major benefit is that all front-end chip technologies can be merged—logic, memory, RF, even passives. ESD protection is required only on external system connections. Manufacturing test information will accurately characterize process faults and thus avoid the Known-Good-Die problem that has slowed the arrival of conventional MCM's.
Quasi-CW 110 kW AlGaAs Laser Diode Array Module for Inertial Fusion Energy Laser Driver
NASA Astrophysics Data System (ADS)
Kawashima, Toshiyuki; Kanzaki, Takeshi; Matsui, Ken; Kato, Yoshinori; Matsui, Hiroki; Kanabe, Tadashi; Yamanaka, Masanobu; Nakatsuka, Masahiro; Izawa, Yasukazu; Nakai, Sadao; Miyamoto, Masahiro; Kan, Hirofumi; Hiruma, Teruo
2001-12-01
We have successfully demonstrated a large aperture 803 nm AlGaAs diode laser module as a pump source for a 1053 nm, 10 J output Nd:glass slab laser amplifier for diode-pumped solid-state laser (DPSSL) fusion driver. Detailed performance results of the laser diode module are presented, including bar package and stack configuration, and their thermal design and analysis. A sufficiently low thermal impedance of the stack was realized by combining backplane liquid cooling configuration with modular bar package architecture. Total peak power of 110 kW and electrical to optical conversion efficiency of 46% were obtained from the module consisting of a total of 1000 laser diode bars. A peak intensity of 2.6 kW/cm2 was accomplished across an emitting area of 418 mm× 10 mm. Currently, this laser diode array module with a large two-dimensional aperture is, to our knowledge, the only operational pump source for the high output energy DPSSL.
Mair, Patrick; Hofmann, Eva; Gruber, Kathrin; Hatzinger, Reinhold; Zeileis, Achim; Hornik, Kurt
2015-01-01
One of the cornerstones of the R system for statistical computing is the multitude of packages contributed by numerous package authors. This amount of packages makes an extremely broad range of statistical techniques and other quantitative methods freely available. Thus far, no empirical study has investigated psychological factors that drive authors to participate in the R project. This article presents a study of R package authors, collecting data on different types of participation (number of packages, participation in mailing lists, participation in conferences), three psychological scales (types of motivation, psychological values, and work design characteristics), and various socio-demographic factors. The data are analyzed using item response models and subsequent generalized linear models, showing that the most important determinants for participation are a hybrid form of motivation and the social characteristics of the work design. Other factors are found to have less impact or influence only specific aspects of participation. PMID:26554005
Mair, Patrick; Hofmann, Eva; Gruber, Kathrin; Hatzinger, Reinhold; Zeileis, Achim; Hornik, Kurt
2015-12-01
One of the cornerstones of the R system for statistical computing is the multitude of packages contributed by numerous package authors. This amount of packages makes an extremely broad range of statistical techniques and other quantitative methods freely available. Thus far, no empirical study has investigated psychological factors that drive authors to participate in the R project. This article presents a study of R package authors, collecting data on different types of participation (number of packages, participation in mailing lists, participation in conferences), three psychological scales (types of motivation, psychological values, and work design characteristics), and various socio-demographic factors. The data are analyzed using item response models and subsequent generalized linear models, showing that the most important determinants for participation are a hybrid form of motivation and the social characteristics of the work design. Other factors are found to have less impact or influence only specific aspects of participation.
NASA Astrophysics Data System (ADS)
Fu, Enjin
Demand for more bandwidth is rapidly increasing, which is driven by data intensive applications such as high-definition (HD) video streaming, cloud storage, and terascale computing applications. Next-generation high-performance computing systems require power efficient chip-to-chip and intra-chip interconnect yielding densities on the order of 1Tbps/cm2. The performance requirements of such system are the driving force behind the development of silicon integrated optical interconnect, providing a cost-effective solution for fully integrated optical interconnect systems on a single substrate. Compared to conventional electrical interconnect, optical interconnects have several advantages, including frequency independent insertion loss resulting in ultra wide bandwidth and link latency reduction. For high-speed optical transmitter modules, the optical modulator is a key component of the optical I/O channel. This thesis presents a silicon integrated optical transmitter module design based on a novel silicon HBT-based carrier injection electroabsorption modulator (EAM), which has the merits of wide optical bandwidth, high speed, low power, low drive voltage, small footprint, and high modulation efficiency. The structure, mechanism, and fabrication of the modulator structure will be discussed which is followed by the electrical modeling of the post-processed modulator device. The design and realization of a 10Gbps monolithic optical transmitter module integrating the driver circuit architecture and the HBT-based EAM device in a 130nm BiCMOS process is discussed. For high power efficiency, a 6Gbps ultra-low power driver IC implemented in a 130nm BiCMOS process is presented. The driver IC incorporates an integrated 27-1 pseudo-random bit sequence (PRBS) generator for reliable high-speed testing, and a driver circuit featuring digitally-tuned pre-emphasis signal strength. With outstanding drive capability, the driver module can be applied to a wide range of carrier injection modulators and light-emitting diodes (LED) with drive voltage requirements below 1.5V. Measurement results show an optical link based on a 70MHz red LED work well at 300Mbps by using the pre-emphasis driver module. A traveling wave electrode (TWE) modulator structure is presented, including a novel design methodology to address process limitations imposed by a commercial silicon fabrication technology. Results from 3D full wave EM simulation demonstrate the application of the design methodology to achieve specifications, including phase velocity matching, insertion loss, and impedance matching. Results show the HBT-based TWE-EAM system has the bandwidth higher than 60GHz.
Infectious complications after vehicular trauma in the United States.
Fraser, Douglas R; Dombrovskiy, Viktor Y; Vogel, Todd R
2011-08-01
The purpose of this analysis was to evaluate and define the rates of infectious complications (IC) after vehicular trauma. Secondary goals were to identify the injuries associated with the greatest risk of nosocomial infection and to measure the utilization of hospital resources associated with IC and vehicular trauma. A secondary analysis of the Nationwide Inpatient Sample (2003-2007) was performed to classify major vehicular trauma injuries utilizing International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) Emergency (E) codes. The post-traumatic IC evaluated were pneumonia, urinary tract infection (UTI), sepsis, and surgical site infection (SSI). All data were analyzed by χ(2) analysis, multivariable logistic regression, and the Cochran-Armitage test for trends. A total of 784,037 vehicular trauma patients were identified (462,543 [59.0%] motor vehicle drivers, 142,283 [18.2%] motor vehicle passengers, 98,767 [12.6%] motorcyclists; 6,568 [<1%] motorcycle passengers, and 73,876 [9.4%] pedestrians). Of those sustaining injuries, 44,331 [5.7%] had post-traumatic IC. Pneumonia and UTI were most common after spinal cord injury (SCI), whereas sepsis and SSI were most common after colon injuries. After adjustment by age, sex, and co-morbidities, patients with SCI were 4.4 times as likely (95% confidence interval [CI] 4.20-4.63) and those with cranial injuries were 2.1 times as likely (95% CI 2.06-2.19) to develop IC as patients without these injuries. Secondary infection increased significantly the length of stay and hospital charges in all groups. Patients sustaining vehicular trauma in combination with SCI had the highest rate of IC. Infectious complications increased hospital resource utilization significantly after vehicular trauma. Future root-cause analysis of high-risk groups may decrease complications and hospital utilization.
New Risk Curves for NHTSA's Brain Injury Criterion (BrIC): Derivations and Assessments.
Laituri, Tony R; Henry, Scott; Pline, Kevin; Li, Guosong; Frankstein, Michael; Weerappuli, Para
2016-11-01
The National Highway Traffic Safety Administration (NHTSA) recently published a Request for Comments regarding a potential upgrade to the US New Car Assessment Program (US NCAP) - a star-rating program pertaining to vehicle crashworthiness. Therein, NHTSA (a) cited two metrics for assessing head risk: Head Injury Criterion (HIC15) and Brain Injury Criterion (BrIC), and (b) proposed to conduct risk assessment via its risk curves for those metrics, but did not prescribe a specific method for applying them. Recent studies, however, have indicated that the NHTSA risk curves for BrIC significantly overstate field-based head injury rates. Therefore, in the present three-part study, a new set of BrIC-based risk curves was derived, an overarching head risk equation involving risk curves for both BrIC and HIC15 was assessed, and some additional candidatepredictor- variable assessments were conducted. Part 1 pertained to the derivation. Specifically, data were pooled from various sources: Navy volunteers, amateur boxers, professional football players, simple-fall subjects, and racecar drivers. In total, there were 4,501 cases, with brain injury reported in 63. Injury outcomes were approximated on the Abbreviated Injury Scale (AIS). The statistical analysis was conducted subject to ordinal logistic regression analysis (OLR), such that the various levels of brain injury were cast as a function of BrIC. The resulting risk curves, with Goodman Kruksal Gamma=0.83, were significantly different than those from NHTSA. Part 2 pertained to the assessment relative to field data. Two perspectives were considered: "aggregate" (ΔV=0-56 km/h) and "point" (high-speed, regulatory focus). For the aggregate perspective, the new risk curves for BrIC were applied in field models pertaining to belted, mid-size, adult drivers in 11-1 o'clock, full-engagement frontal crashes in the National Automotive Sampling System (NASS, 1993-2014 calendar years). For the point perspective, BrIC data from tests were used. The assessments were conducted for minor, moderate, and serious injury levels for both Newer Vehicles (airbag-fitted) and Older Vehicles (not airbag-fitted). Curve-based injury rates and NASS-based injury rates were compared via average percent difference (AvgPctDiff). The new risk curves demonstrated significantly better fidelity than those from NHTSA. For example, for the aggregate perspective (n=12 assessments), the results were as follows: AvgPctDiff (present risk curves) = +67 versus AvgPctDiff (NHTSA risk curves) = +9378. Part 2 also contained a more comprehensive assessment. Specifically, BrIC-based risk curves were used to estimate brain-related injury probabilities, HIC15-based risk curves from NHTSA were used to estimate bone/other injury probabilities, and the maximum of the two resulting probabilities was used to represent the attendant headinjury probabilities. (Those HIC15-based risk curves yielded AvgPctDiff=+85 for that application.) Subject to the resulting 21 assessments, similar results were observed: AvgPctDiff (present risk curves) = +42 versus AvgPctDiff (NHTSA risk curves) = +5783. Therefore, based on the results from Part 2, if the existing BrIC metric is to be applied by NHTSA in vehicle assessment, we recommend that the corresponding risk curves derived in the present study be considered. Part 3 pertained to the assessment of various other candidate brain-injury metrics. Specifically, Parts 1 and 2 were revisited for HIC15, translation acceleration (TA), rotational acceleration (RA), rotational velocity (RV), and a different rotational brain injury criterion from NHTSA (BRIC). The rank-ordered results for the 21 assessments for each metric were as follows: RA, HIC15, BRIC, TA, BrIC, and RV. Therefore, of the six studied sets of OLR-based risk curves, the set for rotational acceleration demonstrated the best performance relative to NASS.
OWL representation of the geologic timescale implementing stratigraphic best practice
NASA Astrophysics Data System (ADS)
Cox, S. J.
2011-12-01
The geologic timescale is a cornerstone of the earth sciences. Versions are available from many sources, with the following being of particular interest: (i) The official International Stratigraphic Chart (ISC) is maintained by the International Commission for Stratigraphy (ICS), following principles developed over the last 40 years. ICS provides the data underlying the chart as part of a specialized software package, and the chart itself as a PDF using the standard colours; (ii) ITC Enschede has developed a representation of the timescale as a thesaurus in SKOS, used in a Web Map Service delivery system; (iii) JPL's SWEET ontology includes a geologic timescale. This takes full advantage of the capabilities of OWL. However, each of these has limitations - The ISC falls down because of incompatibility with web technologies; - While SKOS supports multilingual labelling, SKOS does not adequately support timescale semantics, in particular since it does not include ordering relationships; - The SWEET version (as of version 2) is not fully aligned to the model used by ICS, in particular not recognizing the role of the Global Boundary Stratotype Sections and Point (GSSP). Furthermore, it is distributed as static documents, rather than through a dynamic API using SPARQL. The representation presented in this paper overcomes all of these limitations as follows: - the timescale model is formulated as an OWL ontology - the ontology is directly derived from the UML representation of the ICS best practice proposed by Cox & Richard [2005], and subsequently included as the Geologic Timescale package in GeoSciML (http://www.geosciml.org); this includes links to GSSPs as per the ICS process - key properties in the ontology are also asserted to be subProperties of SKOS properties (topConcept and broader/narrower relations) in order to support SKOS-based queries; SKOS labelling is used to support multi-lingual naming and synonyms - the International Stratigraphic Chart is implemented as a set of instances of classes from the ontology, and published through a SPARQL end-point - the elements of the Stratigraphic chart are linked to the corresponding elements in SWEET (Raskin et al., 2011) and DBpedia to support traceability between different commonly accessed representations. The ontology builds on standard geospatial information models, including the Observations and Measurements model (ISO 19156), and GeoSciML. This allows the ages given in the chart to be linked to the evidence basis found in the associated GeoSciML features.
NASA Astrophysics Data System (ADS)
Lee, Yong Wook; Yoon, Hyung Do; Park, Jae-Hyoun; Ryu, Uh-Chan
2018-05-01
UV LED lightings have been displacing conventional UV lamps due to their high efficiency, long lifetime, etc. A sterilizing lighting was prepared by assembling a UV LED module composed of 265-nm UVC LEDs and a silica lens array with a driver module comprised of a driver IC controlling pulse width modulation and constant current. The silica lens array was designed and fabricated to focus UV beam and simultaneously to give a uniform light distribution over specimens. Then pasteurizing effect of the lighting was analyzed for four kinds of bacteria and one yeast which are dangerous to people with low immunity. Sterilizing tests on these germs were carried out at the both exposure distances of 10 and 100 mm for various exposure durations up to 600 s.
Design and implementation of Ada programs to facilitate automated testing
NASA Technical Reports Server (NTRS)
Dean, Jack; Fox, Barry; Oropeza, Michael
1991-01-01
An automated method utilized to test the software components of COMPASS, an interactive computer aided scheduling system, is presented. Each package of this system introduces a private type, and works to construct instances of that type, along with read and write routines for that type. Generic procedures that can generate test drivers for these functions are given and show how the test drivers can read from a test data file the functions to call, the arguments for those functions, what the anticipated result should be, and whether an exception should be raised for the function given the arguments.
Iterative categorization (IC): a systematic technique for analysing qualitative data.
Neale, Joanne
2016-06-01
The processes of analysing qualitative data, particularly the stage between coding and publication, are often vague and/or poorly explained within addiction science and research more broadly. A simple but rigorous and transparent technique for analysing qualitative textual data, developed within the field of addiction, is described. The technique, iterative categorization (IC), is suitable for use with inductive and deductive codes and can support a range of common analytical approaches, e.g. thematic analysis, Framework, constant comparison, analytical induction, content analysis, conversational analysis, discourse analysis, interpretative phenomenological analysis and narrative analysis. Once the data have been coded, the only software required is a standard word processing package. Worked examples are provided. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Asynchronous Discrete Control of Continuous Processes.
1986-02-24
Input. When 40-lead dual-in-line ceramic packages (D suffix) and in the mode input is high IMOOE=1), the CDPIS54A is 40-lead dual-in-line plastic ...DYNAIC U ThIi. CA~ YRi5iC5 TACDPI8541 CDPI854C DYNAMC LECRICL CARA ERITIC atTA 40 o +UC. DD M W O 1110 VlH’& 7 VDD. VIL, 3 . LIIMTS ’.- CARACTERISTIC
NASA Astrophysics Data System (ADS)
Hoffmann, T. L.; Lauterjung, J.
2016-12-01
The European Plate Observing System project is currently approaching the end of year one of its four-year Implementation Phase 2015-18 (EPOS-IP). Established under the Horizon 2020 Programme INFRADEV-3, the EPOS cyberinfrastructure is being established as an ERIC (European Research Infrastructure Consortium) and encompasses the implementation of both the EPOS Integrated Core Services (ICS) for solid Earth Science and a multitude of EPOS Thematic Core Services (TCS). The TCS-Elements themselves will integrate a number of Service Providers that deliver Data, Data Products, Services and Software (DDSS) to their specific scientific community. As one of the 29 awardees of the EC grant, the German Research Center for Geosciences (GFZ) plays an important role in the implementation of EPOS and its Thematic and Integrated Core Services. The presented poster will give an overview of GFZ's participation in nine technical EPOS Work Packages (WP7 ICS Development, WP8 Seismology, WP11 Volcano Observations, WP12 Satellite Data, WP13 Geomagnetic Observations, WP14 Anthropogenic Hazards, WP15 Geological Information and Modelling, WP16 Multi-Scale Laboratories and WP17 Geo Energy Test Beds) as well as in four administrative EPOS Work Packages (WP2 Communication, WP3 Harmonization, WP4 Legal & Governance, and WP5 Financial).
A programmable CCD driver circuit for multiphase CCD operation
NASA Technical Reports Server (NTRS)
Ewin, Audrey J.; Reed, Kenneth V.
1989-01-01
A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.
Universal programming interface with concurrent access
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alferov, Oleg
2004-10-07
There exist a number of devices with a positioning nature of operation, such as mechanical linear stages, temperature controllers, or filterwheels with discrete state, and most of them have different programming interfaces. The Universal Positioner software suggests the way to handle all of them is with a single approach, whereby a particular hardware driver is created from the template and by translating the actual commands used by the hardware to and from the universal programming interface. The software contains the universal API module itself, the demo simulation of hardware, and the front-end programs to help developers write their own softwaremore » drivers along with example drivers for actual hardware controllers. The software allows user application programs to call devices simultaneously without race conditions (multitasking and concurrent access). The template suggested in this package permits developers to integrate various devices easily into their applications using the same API. The drivers can be stacked; i.e., they can call each other via the same interface.« less
S-Band POSIX Device Drivers for RTEMS
NASA Technical Reports Server (NTRS)
Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.
2011-01-01
This is a set of POSIX device driver level abstractions in the RTEMS RTOS (Real-Time Executive for Multiprocessor Systems real-time operating system) to SBand radio hardware devices that have been instantiated in an FPGA (field-programmable gate array). These include A/D (analog-to-digital) sample capture, D/A (digital-to-analog) sample playback, PLL (phase-locked-loop) tuning, and PWM (pulse-width-modulation)-controlled gain. This software interfaces to Sband radio hardware in an attached Xilinx Virtex-2 FPGA. It uses plug-and-play device discovery to map memory to device IDs. Instead of interacting with hardware devices directly, using direct-memory mapped access at the application level, this driver provides an application programming interface (API) offering that easily uses standard POSIX function calls. This simplifies application programming, enables portability, and offers an additional level of protection to the hardware. There are three separate device drivers included in this package: sband_device (ADC capture and DAC playback), pll_device (RF front end PLL tuning), and pwm_device (RF front end AGC control).
Kuesten, Carla; Bi, Jian
2018-06-03
Conventional drivers of liking analysis was extended with a time dimension into temporal drivers of liking (TDOL) based on functional data analysis methodology and non-additive models for multiple-attribute time-intensity (MATI) data. The non-additive models, which consider both direct effects and interaction effects of attributes to consumer overall liking, include Choquet integral and fuzzy measure in the multi-criteria decision-making, and linear regression based on variance decomposition. Dynamics of TDOL, i.e., the derivatives of the relative importance functional curves were also explored. Well-established R packages 'fda', 'kappalab' and 'relaimpo' were used in the paper for developing TDOL. Applied use of these methods shows that the relative importance of MATI curves offers insights for understanding the temporal aspects of consumer liking for fruit chews.
ERIC Educational Resources Information Center
National Center on Safe Supportive Learning Environments, 2017
2017-01-01
Improving school climate takes time and commitment from a variety of people in a variety of roles. This document outlines key action steps that noninstructional staff--including guidance counselors, social workers, school psychologists, office staff, bus drivers, maintenance and facility staff, and food service staff--can take to support school…
Investigation of Surface Phenomena in Shocked Tin in Converging Geometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rousculp, Christopher L.; Oro, David Michael; Griego, Jeffrey Randall
2016-04-14
There is a great interest in RMI as source of ejecta from metal shells. Previous experiments have explored wavelength amplitude (kA) variation but they have a small range of drive pressures and are in planer geometry. Simulations, both MD and hydro, have explored RMI in planer geometry. The ejecta source model from RMI is an area of active algorithm and code development in ASCI-IC Lagrangian Applications Project. PHELIX offers precise, reproducible variable driver for Hydro and material physics diagnoses with proton radiography.
Three-Dimensional Integrated Circuit (3D IC) Key Technology: Through-Silicon Via (TSV).
Shen, Wen-Wei; Chen, Kuan-Neng
2017-12-01
3D integration with through-silicon via (TSV) is a promising candidate to perform system-level integration with smaller package size, higher interconnection density, and better performance. TSV fabrication is the key technology to permit communications between various strata of the 3D integration system. TSV fabrication steps, such as etching, isolation, metallization processes, and related failure modes, as well as other characterizations are discussed in this invited review paper.
Methods for Integrating Environmental Awareness Training into Army Programs of Instruction
1993-06-01
generations. iv NTIS CRA&I ) F -IC TAB U.a’mot’::ed El By .. . ... ....... By .......................... ...... . .. DiO t, ib., tion I CONTENTS...Training Support Package ................... E-1-E-19 Appendix F . Sample of Officer Basic Course Instructor’s Lesson Plan with Embedded Information... F -1- F -7 Appendix G. Samples of Situational Training Exercises ........... G-1-G 9 Appendix H. Samples of Pre-Command Course Guest Speaker
Development of Optimization Procedure for Design of Package Cushioning
1975-01-01
Sheller-Globe Corp, Polyurethane None GAF Corp. Felt Not uaeful National Bureau of Standards Anything available None Plastics Tech- nical...000517 ■’■■ LIABLE ASSIGNMENTS HEMP I OSOSJJCG! S?c " ÜSJ0 Ic ■ nooooicoi IITM - oooooacoi *’ : EF §■ : ES S...absorb.relatively small amounts of energy and recover most of the cushion thickness in a short time. An example is a lightweight open-celled plastic
1.8V Operation Power Amplifier IC for Bluetooth Class 1 Utilizing p+-GaAs Gate Hetero-Junction FET
NASA Astrophysics Data System (ADS)
Harima, Fumio; Bito, Yasunori; Takahashi, Hidemasa; Iwata, Naotaka
We have developed a power amplifier IC for Bluetooth Class 1 operating at single low voltage of 1.8V for both control and drain voltages. We can realize it due to fully enhancement-mode hetero-junction FETs utilizing a re-grown p+-GaAs gate technology. The power amplifier is a highly compact design as a small package of 1.5mm×1.5mm×0.4mm with fully integrated gain control and shutdown functions. An impressive power added efficiency of 52% at an output power of 20dBm is achieved with an associated gain of 22dB. Also, sufficiently low leakage current of 0.25μA at 27°C is exhibited, which is comparable to conventional HBT power amplifiers.
Turusbekova, N; Popa, C; Dragos, M; van der Werf, M J; Dinca, I
2016-02-01
In 2012, the tuberculosis (TB) notification rate among Romanian TB facility doctors and nurses was 7.2 times higher than in the general population. This indicates that transmission is ongoing inside TB facilities and that TB infection control measures are insufficient. To help prevent nosocomial TB transmission a project was implemented that aimed at providing nationwide tailor-made technical assistance in TB infection control (TB-IC) in TB treatment facilities, including the development of TB infection control plans. The objective of the present article is to describe the implementation of the project and to discuss successes and challenges. The project was an implementation study using two methods of evaluation: (1) a cross sectional questionnaire study; and (2) collection of information, during the training, on challenges related to infection control and to the project implementation. The project team developed a TB facility infection control (TB-IC) plan template, together with the Romanian experts. The template was discussed and agreed upon with the experts at a meeting and thereafter distributed by email to all TB facilities. Afterwards, a training of trainers (TOT) seminar was organized which included the provision of information about different training methods, as well as information about TB-IC. The TOT was followed by training for key TB-IC providers. Information about use of the TB-IC template was gathered through a self-administered questionnaire sent to all participants of the expert meeting and the training (42 people). Additionally, non-systematized discussions were held on broader challenges in TB-IC implementation during the training. Within the project 42 key TB-IC service providers were trained in TB-IC, including 9 who were trained at a TOT seminar. The trainees were specialists working at the national level, such as country TB coordinators, or at the TB facility level: TB doctors, epidemiologists, laboratory specialists and maintenance engineers. Out of 42 key TB-IC service providers who were trained, only eighteen responded to the questionnaire (no reminders were sent). Out of these, 14 had used the TB-IC plan template after the project team disseminated it to them by email. The remaining four TB-IC service providers indicated that they were planning to use the template to develop or update their facility TB-IC plans. Related to the use of TB-IC plan template, the following broader challenges in TB-IC were identified: a lack of authority of the individuals responsible for TB-IC to implement the TB-IC measures, lack of training among facility epidemiologists on TB, underdeveloped system for reporting TB in healthcare workers, difficulties with triage of the TB suspects, and poor facility infrastructure hampering implementation of TB-IC measures. Implementing TB-IC plans in Romanian health care facilities proved to be challenging, mainly due to the fact that the national infection control plan for TB was not yet adopted at the time of project implementation, and therefore there was neither a regulatory framework to support TB facility-IC planning nor any related budget allocations for the implementation of the facilities' TB-IC plans. Nonetheless, most respondents who answered the questionnaire (18 of 42 responded) indicated that they had started using the TB-IC plan template, which represents a full package of infection control measures that, when implemented effectively and in its entirety, may be expected to reduce nosocomial transmission. The study's limitations are: very low survey response rate, thus there is a likelihood of responder bias. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayashi, Hirokazu
One-dimensional (1D) molecular chains of 4-substituted-2,2,6,6-tetramethyl-1-piperidinyloxyl (4-X-TEMPO) radicals were constructed in the crystalline 1D nanochannels of 2,4,6-tris(4-chlorophenoxy)-1,3,5-triazine (CLPOT) used as a template. The ESR spectra of CLPOT inclusion compounds (ICs) using 4-X-TEMPO were examined on the basis of spectral simulation using EasySpin program package for simulating and fitting ESR spectra. The ESR spectra of [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC were isotropic in the total range of temperatures. The peak-to-peak line width (ΔB{sub pp}) became monotonically narrower from 2.8 to 1.3 mT with increase in temperature in the range of 4.2–298 K. The effect of the rotational diffusion motion of TEMPO radicals inmore » the CLPOT nanochannels for the inter-spin interaction of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC was found to be smaller than the case of [(TPP){sub 2}−(TEMPO){sub 1.0}] IC (TPP = tris(o-phenylenedioxy)cyclotriphosphazene) reported in our previous study. The ΔB{sub pp} of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC in the whole range of temperatures was much narrower than the estimation to be based on the Van Vleck’s formula for the second moment of the rigid lattice model where the electron spin can be considered as fixed; 11 mT of Gaussian line-width component. This suggests the possibility of exchange narrowing in the 1D organic-radical chains of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC. On the other hand, the ESR spectra of [(CLPOT){sub 2}-(MeO-TEMPO){sub 0.41}] IC (MeO-TEMPO = 4-methoxy-TEMPO) were reproduced by a superposition of major broad isotropic adsorption line and minor temperature-dependent modulated triplet component. This suggests that the IC has the part of 1D organic-radical chains and MeO-TEMPO molecules isolated in the CLPOT nanochannels.« less
Stucki, Sheldon Lee; Biss, David J.
2000-01-01
An analysis was performed using the National Automotive Sampling System Crashworthiness Data System (NASS-CDS) database to compare the injury/fatality rates of variously restrained driver occupants as compared to unrestrained driver occupants in the total database of drivers/frontals, and also by Delta-V. A structured search of the NASS-CDS was done using the SAS® statistical analysis software to extract the data for this analysis and the SUDAAN software package was used to arrive at statistical significance indicators. In addition, this paper goes on to investigate different methods for presenting results of accident database searches including significance results; a risk versus Delta-V format for specific exposures; and, a percent cumulative injury versus Delta-V format to characterize injury trends. These alternative analysis presentation methods are then discussed by example using the present study results. PMID:11558105
Advanced packaging for Integrated Micro-Instruments
NASA Technical Reports Server (NTRS)
Lyke, James L.
1995-01-01
The relationship between packaging, microelectronics, and micro-electrical-mechanical systems (MEMS) is an important one, particularly when the edges of performance boundaries are pressed, as in the case of miniaturized systems. Packaging is a sort of physical backbone that enables the maximum performance of these systems to be realized, and the penalties imposed by conventional packing approaches is particularly limiting for MEMS devices. As such, advanced packaging approaches, such as multi-chip modules (MCM's) have been touted as a true means of electronic 'enablement' for a variety of application domains. Realizing an optimum system of packaging, however, in not as simple as replacing a set of single chip packages with a substrate of interconnections. Research at Phillips Laboratory has turned up a number of integrating options in the two- and three-dimensional rending of miniature systems with physical interconnection structures with intrinsically high performance. Not only do these structures motivate the redesign of integrated circuits (IC's) for lower power, but they possess interesting features that provide a framework for the direct integration of MEMS devices. Cost remains a barrier to the application of MEMS devices, even in space systems. Several innovations are suggested that will result in lower cost and more rapid cycle time. First, the novelty of a 'constant floor plan' MCM which encapsulates a variety of commonly used components into a stockable, easily customized assembly is discussed. Next, the use of low-cost substrates is examined. The anticipated advent of ultra-high density interconnect (UHDI) is suggested as the limit argument of advanced packaging. Finally, the concept of a heterogeneous 3-D MCM system is outlined that allows for the combination of different compatible packaging approaches into a uniformly dense structure that could also include MEMS-based sensors.
Heavy Ion Microbeam- and Broadbeam-Induced Transients in SiGe HBTs
NASA Technical Reports Server (NTRS)
Pellish, Jonathan A.; Reed, Robert A.; McMorrow, Dale; Vizkelethy, Gyorgy; Ferlet-Cavrois, Veronique; Baggio, Jacques; Duhamel, Olivier; Moen, Kurt A.; Phillips, Stanley D.; Diestelhorst, Ryan M.;
2009-01-01
SiGe HBT heavy ion-induced current transients are measured using Sandia National Laboratories microbeam and high- and low-energy broadbeam sources at the Grand Accelerateur National d'Ions Lourds and the University of Jyvaskyla. The data were captured using a custom broadband IC package and real-time digital phosphor oscilloscopes with at least 16 GHz of analog bandwidth. These data provide detailed insight into the effects of ion strike location, range, and LET.
2009-01-01
coatings include flexible liquid crystal displays, OLEDs , and photovoltaic modules.15 Additional applications include packaging for medical devices...copyright, see http://jap.aip.org/jap/copyright.jsp ics of TFT Technology on Flexible Substrates, Flexible Flat Panel Dis- plays, edited by G. P. Crawford...grade “Teonex Q65” is commonly used in the organic light emitting diode OLED field because it is both heat stabilized and coated with a scratch
Single-Event Latchup Testing of the Micrel MIC4424 Dual Power MOSFET Driver
NASA Technical Reports Server (NTRS)
Pellish, J. A.; Boutte, A.; Kim, H.; Phan, A.; Topper, A.
2016-01-01
We conducted 47 exposures of four different MIC4424 devices and did not observe any SEL or high-current events. This included worst-case conditions with a LET of 81 MeV-sq cm/mg, applied voltage of 18.5 V, a case temperature greater than 120 C, and a final fluence of 1x10(exp 7)/sq cm. We also monitored both the outputs for the presence of SETs. While the period of the 1 MHz square wave was slightly altered in some cases, no pulses were added or deleted. 1. Purpose: The purpose of this testing is to characterize the BiCMOS/DMOS Micrel MIC4424 dual, non-inverting MOSFET driver for single-event latchup (SEL) susceptibility. These data will be used for flight lot evaluation purposes. 2. Devices Tested: The MIC4423/4424/4425 family are highly reliable BiCMOS/DMOS buffer/driver MOSFET drivers. They are higher output current versions of the MIC4426/4427/4428. They can survive up to 5V of noise spiking, of either polarity, on the ground pin. They can accept, without either damage or logic upset, up to half an amp of reverse current (either polarity) forced back into their outputs. Primarily intended for driving power MOSFETs, the MIC4423/4424/4425 drivers are suitable for driving other loads (capacitive, resistive, or inductive) which require low-impedance, high peak currents, and fast switching times. Heavily loaded clock lines, coaxial cables, or piezoelectric transducers are some examples. The only known limitation on loading is that total power dissipated in the driver must be kept within the maximum power dissipation limits of the package. Five (5) parts were provided for SEL testing. We prepared four parts for irradiation and reserved one piece as an un-irradiated control. More information about the devices can be found in Table 1. The parts were prepared for testing by removing the lid from the CDIP package to expose the target die. The parts were then soldered to small copper circuit adapter boards for easy handling. These parts are fabricated in a bulk BiCMOS/DMOS technology. Since we do not know the number of overlayers used in the fabrication processes, linear energy transfer calculations are determined based on the top-surface incident ion species and kinetic energy.
Radiation Testing and Evaluation Issues for Modern Integrated Circuits
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Cohn, Lew M.
2005-01-01
Abstract. Changes in modern integrated circuit (IC) technologies have modified the way we approach and conduct radiation tolerance and testing of electronics. These changes include scaling of geometries, new materials, new packaging technologies, and overall speed and device complexity challenges. In this short course section, we will identify and discuss these issues as they impact radiation testing, modeling, and effects mitigation of modern integrated circuits. The focus will be on CMOS-based technologies, however, other high performance technologies will be discussed where appropriate. The effects of concern will be: Single-Event Effects (SEE) and steady state total ionizing dose (TID) IC response. However, due to the growing use of opto-electronics in space systems issues concerning displacement damage testing will also be considered. This short course section is not intended to provide detailed "how-to-test" information, but simply provide a snapshot of current challenges and some of the approaches being considered.
NASA Astrophysics Data System (ADS)
Hamidnia, Mohammad; Luo, Yi; Wang, Xiaodong; Li, Congming
2017-10-01
Increasing component densities of the integrated circuit (IC) and packaging levels has led to thermal management problems. Si substrates with embedded micro-heat pipes (MHPs) couple good thermal characteristics and cost savings associated with IC batch processing. The thermal performance of MHP is intimately related to the cross-sectional geometry. Different cross-sections are designed in order to enhance the backflow of working fluid. In this experimental study, three different Si MHPs with same hydraulic diameter and various cross-sections are fabricated by micro-fabrication methods and tested under different conditions of fluid charge ratios. The results show that the trapezoidal MHP associated with rectangular artery which is charged with 40% of vapor chamber’s volume has the best thermal performance. This silicon-based MHP is a passive approach for thermal management, which could widen applications in the commercial electronics industry and LED lightings.
Equivalent radiation source of 3D package for electromagnetic characteristics analysis
NASA Astrophysics Data System (ADS)
Li, Jun; Wei, Xingchang; Shu, Yufei
2017-10-01
An equivalent radiation source method is proposed to characterize electromagnetic emission and interference of complex three dimensional integrated circuits (IC) in this paper. The method utilizes amplitude-only near-field scanning data to reconstruct an equivalent magnetic dipole array, and the differential evolution optimization algorithm is proposed to extract the locations, orientation and moments of those dipoles. By importing the equivalent dipoles model into a 3D full-wave simulator together with the victim circuit model, the electromagnetic interference issues in mixed RF/digital systems can be well predicted. A commercial IC is used to validate the accuracy and efficiency of this proposed method. The coupled power at the victim antenna port calculated by the equivalent radiation source is compared with the measured data. Good consistency is obtained which confirms the validity and efficiency of the method. Project supported by the National Nature Science Foundation of China (No. 61274110).
Controlling Precision Stepper Motors in Flight Using (Almost) No Parts
NASA Technical Reports Server (NTRS)
Randall, David
2010-01-01
This concept allows control of high-performance stepper motors with minimal parts count and minimal flight software complexity. Although it uses a small number of common flight-qualified parts and simple control algorithms, it is capable enough to meet demanding system requirements. Its programmable nature makes it trivial to implement changes to control algorithms both during integration & test and in flight. Enhancements such as microstepping, half stepping, back-emf compensation, and jitter reduction can be tailored to the requirements of a large variety of stepper motor based applications including filter wheels, focus mechanisms, antenna tracking subsystems, pointing and mobility. The hardware design (using an H-bridge motor controller IC) was adapted from JPL's MER mission, still operating on Mars. This concept has been fully developed and incorporated into the MCS instrument on MRO, currently operating in Mars orbit. It has been incorporated into the filter wheel mechanism and linear stage (focus) mechanism for the AMT instrument. On MCS/MRO, two of these circuits control the elevation and azimuth of the MCS telescope/radiometer assembly, allowing the instrument to continuously monitor the limb of the Martian atmosphere. Implementation on MCS/MRO resulted in a 4:1 reduction in the volume and mass required for the motor driver electronics (100:25 square inches of PCB space), producing a very compact instrument. In fact, all of the electronics for the MCS instrument are packaged within the movable instrument structure. It also saved approximately 3 Watts of power. Most importantly, the design enabled MCS to meet very its stringent maximum allowable torque disturbance requirements.
Laser applications in advanced chip packaging
NASA Astrophysics Data System (ADS)
Müller, Dirk; Held, Andrew; Pätzel, Rainer; Clark, Dave; van Nunen, Joris
2016-03-01
While applications such as drilling μ-vias and laser direct imaging have been well established in the electronics industry, the mobile device industry's push for miniaturization is generating new demands for packaging technologies that allow for further reduction in feature size while reducing manufacturing cost. CO lasers have recently become available and their shorter wavelength allows for a smaller focus and drilling hole diameters down to 25μm whilst keeping the cost similar to CO2 lasers. Similarly, nanosecond UV lasers have gained significantly in power, become more reliable and lower in cost. On a separate front, the cost of ownership reduction for Excimer lasers has made this class of lasers attractive for structuring redistribution layers of IC substrates with feature sizes down to 2μm. Improvements in reliability and lower up-front cost for picosecond lasers is enabling applications that previously were only cost effective with mechanical means or long-pulsed lasers. We can now span the gamut from 100μm to 2μm for via drilling and can cost effectively structure redistribution layers with lasers instead of UV lamps or singulate packages with picosecond lasers.
Paiva, Maria Henriqueta Rocha Siqueira; Oliveira, Adriana Cristina
2011-01-01
This transversal study was carried out with a multiprofessional team in the pre-hospital care in Minas Gerais, Brazil. It aimed to estimate the incidence of occupational accidents by exposure to biological material and post-accidents conductsta. Descriptive analysis and logistic regression were used. Incidence of accidents was 19.8%: 39,1% perforating-cutting materials and 56.5% body fluids. Doctors (33.3%) and drivers (24.0%) were most involved. Inadequate subsequent measures were highly prevalent: no medical assessment (69.6%), no work accident communication issued (91.3%), no measures (52.2%) and no serological follow-up (52.2%). Variables associated with accidents were: age >31 years old (OR = 3,02; IC95%: 1,25 - 7,33; p = 0,014) and working in basic support units (OR = 5,36; IC95%: 1,51 19,08; p = 0,010). The implementation of post-accidents protocols is suggested in order to reduce accidents and under-notification, and increase post-accident follow-up.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soer, Wouter
LED luminaires have seen dramatic changes in cost breakdown over the past few years. The LED component cost, which until recently was the dominant portion of luminaire cost, has fallen to a level of the same order as the other luminaire components, such as the driver, housing, optics etc. With the current state of the technology, further luminaire performance improvement and cost reduction is realized most effectively by optimization of the whole system, rather than a single component. This project focuses on improving the integration between LEDs and drivers. Lumileds has developed a light engine platform based on low-cost high-powermore » LEDs and driver topologies optimized for integration with these LEDs on a single substrate. The integration of driver and LEDs enables an estimated luminaire cost reduction of about 25% for targeted applications, mostly due to significant reductions in driver and housing cost. The high-power LEDs are based on Lumileds’ patterned sapphire substrate flip-chip (PSS-FC) technology, affording reduced die fabrication and packaging cost compared to existing technology. Two general versions of PSS-FC die were developed in order to create the desired voltage and flux increments for driver integration: (i) small single-junction die (0.5 mm 2), optimal for distributed lighting applications, and (ii) larger multi-junction die (2 mm 2 and 4 mm 2) for high-power directional applications. Two driver topologies were developed: a tapped linear driver topology and a single-stage switch-mode topology, taking advantage of the flexible voltage configurations of the new PSS-FC die and the simplification opportunities enabled by integration of LEDs and driver on the same board. A prototype light engine was developed for an outdoor “core module” application based on the multi-junction PSS-FC die and the single-stage switch-mode driver. The light engine meets the project efficacy target of 128 lm/W at a luminous flux greater than 4100 lm, a correlated color temperature (CCT) of 4000K and a color rendering index (CRI) greater than 70.« less
Thévenot, Celine
2017-08-01
This article recalls the state of play of inequality levels and trends in OECD countries, with a special focus on Nordic countries. It sheds light on explaining the drivers of the rise in inequality and its economic consequences. It addresses in particular the issue of redistribution through taxes and transfers. It concludes with an overview of policy packages that should be considered to address the issue of rising inequalities.
Dynamic High-Pressure Behavior of Hierarchical Heterogeneous Geological Materials
2016-04-01
sandwiched between two 25µm FEP copolymer layers attached to the copper driver plate . The total package thickness with thin-film epoxy on all bonding...public release. 3 OUTLINE Page # ABSTRACT 2 1. BACKGROUND 4 2. CHARACTERISTICS OF SAND INVESTIGATED 8 3. PLATE ...constituents, phases, inter-phase boundaries ; distributions in shock states; as well as the structural evolutions which can result in strain
Visible, Durable, Enforceable Institutional Controls: Weldon Spring Site - A 10-Year Journey - 13190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uhlmeyer, Terri; Thompson, Randy; Starr, Ken
2013-07-01
The DOE Office of Legacy Management's (LM's) mission is to manage the DOE's post-closure responsibilities and ensure the future protection of human health and the environment. LM has control and custody of legacy land, structures, and facilities and is responsible for maintaining them at levels suitable for their long-term use. This includes all engineered and institutional controls (ICs) designed as another level of assurance to prevent exposure to residual contamination and waste. The development and management of ICs has been, and continues to be, a critical component to the success of LM surveillance and maintenance activities. Many major federal laws,more » Executive Orders, regulations, and various other drivers influence the establishment and use of ICs at LM sites. LM uses a wide range of ICs to appropriately limit access to, or uses of, land, facilities, and other real and personal properties; protect the environment; maintain the physical safety and security of DOE facilities; and prevent or limit inadvertent human and environmental exposure to residual contaminants and other hazards. The ICs at the Weldon Spring, Missouri, Site were developed in close coordination with federal and state regulators. An Explanation of Significant Differences (ESD) was issued in February 2005, which clarified the use restrictions necessary for the remedial actions specified in the Records of Decision for the separate operable units to remain protective over the long-term. The operable units included the Chemical Plant Operable Unit, the Chemical Plant Groundwater Operable Unit, and the Quarry Residuals Operable Unit. The ESD clarified specific requirements for each site area that needed use restrictions and established how DOE would implement, maintain, and monitor the specific requirements. DOE developed the Long-Term Surveillance and Maintenance Plan for the U.S. Department of Energy Weldon Spring, Missouri, Site (LTS and M Plan) that addressed the full scope of the site management activities necessary to ensure that the Weldon Spring Site remains protective over the long-term. The LTS and M Plan is revised periodically to ensure its applicability to changing site, regulatory, or procedural conditions. In addition to addressing such activities as long-term groundwater monitoring and disposal cell maintenance, the LTS and M Plan was developed and issued to ensure that the use restrictions identified in the ESD were properly imposed and maintained. The LTS and M Plan included a detailed IC Implementation Plan, which includes a process for evaluating and identifying specific IC mechanisms that best accomplish the objectives set out in the ESD. Consistent with EPA guidance on selecting ICs, various IC mechanisms were evaluated, including government controls, proprietary controls, enforcement tools, and informational devices. Where appropriate, redundant mechanisms were employed to increase the effectiveness of the ICs. Information in the IC Implementation Plan includes: (1) a discussion of current site conditions (reflecting post-remedial action conditions for the Chemical Plant and Quarry Areas and the risk-basis for why use restrictions are needed); (2) the objectives of, or performance expectations for, the use restrictions; (3) specific ICs already in place and additional mechanisms identified for implementation; (4) a schedule for implementing additional ICs; (5) procedures for maintaining the ICs and for conducting periodic inspections; and (6) general provisions for the implementing ICs for the site. The actual agreements and documentation of the various ICs are included in an appendix of the LTS and M Plan. These documents are also available via the internet from the authorizing agencies (County, Missouri Department of Natural Resources, EPA, etc.) The Weldon Spring Site personnel have been successful in finalizing each of the ICs that were established for the site. The planning, establishment, and implementation of the ICs was a long and detailed process with several lessons-learned that were identified along the way. (authors)« less
NASA Astrophysics Data System (ADS)
Aggarwal, Ankur
With the semiconductor industry racing toward a historic transition, nano chips with less than 45 nm features demand I/Os in excess of 20,000 that support computing speed in terabits per second, with multi-core processors aggregately providing highest bandwidth at lowest power. On the other hand, emerging mixed signal systems are driving the need for 3D packaging with embedded active components and ultra-short interconnections. Decreasing I/O pitch together with low cost, high electrical performance and high reliability are the key technological challenges identified by the 2005 International Technology Roadmap for Semiconductors (ITRS). Being able to provide several fold increase in the chip-to-package vertical interconnect density is essential for garnering the true benefits of nanotechnology that will utilize nano-scale devices. Electrical interconnections are multi-functional materials that must also be able to withstand complex, sustained and cyclic thermo-mechanical loads. In addition, the materials must be environmentally-friendly, corrosion resistant, thermally stable over a long time, and resistant to electro-migration. A major challenge is also to develop economic processes that can be integrated into back end of the wafer foundry, i.e. with wafer level packaging. Device-to-system board interconnections are typically accomplished today with either wire bonding or solders. Both of these are incremental and run into either electrical or mechanical barriers as they are extended to higher density of interconnections. Downscaling traditional solder bump interconnect will not satisfy the thermo-mechanical reliability requirements at very fine pitches of the order of 30 microns and less. Alternate interconnection approaches such as compliant interconnects typically require lengthy connections and are therefore limited in terms of electrical properties, although expected to meet the mechanical requirements. A novel chip-package interconnection technology is developed to address the IC packaging requirements beyond the ITRS projections and to introduce innovative design and fabrication concepts that will further advance the performance of the chip, the package, and the system board. The nano-structured interconnect technology simultaneously packages all the ICs intact in wafer form with quantum jump in the number of interconnections with the lowest electrical parasitics. The intrinsic properties of nano materials also enable several orders of magnitude higher interconnect densities with the best mechanical properties for the highest reliability and yet provide higher current and heat transfer densities. Nano-structured interconnects provides the ability to assemble the packaged parts on the system board without the use of underfill materials and to enable advanced analog/digital testing, reliability testing, and burn-in at wafer level. This thesis investigates the electrical and mechanical performance of nanostructured interconnections through modeling and test vehicle fabrication. The analytical models evaluate the performance improvements over solder and compliant interconnections. Test vehicles with nano-interconnections were fabricated using low cost electro-deposition techniques and assembled with various bonding interfaces. Interconnections were fabricated at 200 micron pitch to compare with the existing solder joints and at 50 micron pitch to demonstrate fabrication processes at fine pitches. Experimental and modeling results show that the proposed nano-interconnections could enhance the reliability and potentially meet all the system performance requirements for the emerging micro/nano-systems.
Herrick, R T; Tavárez, M A; Harsh, B N; Mellencamp, M A; Boler, D D; Dilger, A C
2016-07-01
The objectives of this study were to determine the effect of 1) immunological castration (Improvest, a gonadotropin releasing factor analog-diphtheria toxoid conjugate) management strategy (age at slaughter and time of slaughter after second dose) and 2) sex on lipid oxidation and sensory characteristics of bacon stored under simulated food service conditions. For Objective 1, immunological castration management strategies included 24-wk-old immunologically castrated (IC) barrows 4, 6, 8, or 10 wk after the second Improvest dose (ASD); 26-wk-old IC barrows 6 wk ASD; and 28-wk-old IC barrows 8 wk ASD ( = 63). Objective 2 ( = 97) included IC barrows, physically castrated (PC) barrows, and gilts slaughtered at 24, 26, and 28 wks of age. Bellies from 2 slaughter dates were manufactured into bacon under commercial conditions. Bacon slices were laid out on parchment paper, packaged in oxygen-permeable poly-vinyl-lined boxes, and frozen (-33°C) for 1, 4, 8, or 12 wk to simulate food service conditions. At the end of each storage period, bacon was evaluated for lipid oxidation, moisture and lipid content, and sensory characteristics. Data from both objectives were analyzed using the MIXED procedure in SAS with belly as the experimental unit. For both objectives, as storage time increased, lipid oxidation of bacon increased ( < 0.01), regardless of management strategy or sex. Also, there was no sex or management strategy × week of frozen storage interaction for any traits evaluated ( ≥ 0.25). For Objective 1, lipid content of bacon from IC barrows increased as time of slaughter ASD increased ( < 0.05), regardless of age at slaughter. Additionally, there were no differences in sensory attributes of bacon across management strategies. For the evaluation of sex effects in Objective 2, lipid oxidation was greater ( < 0.05) in IC barrows compared with PC barrows but was not different than gilts ( > 0.05). After 12 wk of frozen storage, lipid oxidation values for IC barrows, PC barrows, and gilts were still below 0.5 mg malondialdehyde/kg of meat, the threshold at which trained panelists may deem a food to be rancid. In conclusion, bacon shelf life characteristics were not altered by the immunological castration management strategy and bacon from IC barrows was similar to bacon from gilts. Therefore, bacon from IC barrows would result in shelf life and sensory quality similar to PC barrows and gilts.
Robust optical sensors for safety critical automotive applications
NASA Astrophysics Data System (ADS)
De Locht, Cliff; De Knibber, Sven; Maddalena, Sam
2008-02-01
Optical sensors for the automotive industry need to be robust, high performing and low cost. This paper focuses on the impact of automotive requirements on optical sensor design and packaging. Main strategies to lower optical sensor entry barriers in the automotive market include: Perform sensor calibration and tuning by the sensor manufacturer, sensor test modes on chip to guarantee functional integrity at operation, and package technology is key. As a conclusion, optical sensor applications are growing in automotive. Optical sensor robustness matured to the level of safety critical applications like Electrical Power Assisted Steering (EPAS) and Drive-by-Wire by optical linear arrays based systems and Automated Cruise Control (ACC), Lane Change Assist and Driver Classification/Smart Airbag Deployment by camera imagers based systems.
A battery-free multichannel digital neural/EMG telemetry system for flying insects.
Thomas, Stewart J; Harrison, Reid R; Leonardo, Anthony; Reynolds, Matthew S
2012-10-01
This paper presents a digital neural/EMG telemetry system small enough and lightweight enough to permit recording from insects in flight. It has a measured flight package mass of only 38 mg. This system includes a single-chip telemetry integrated circuit (IC) employing RF power harvesting for battery-free operation, with communication via modulated backscatter in the UHF (902-928 MHz) band. An on-chip 11-bit ADC digitizes 10 neural channels with a sampling rate of 26.1 kSps and 4 EMG channels at 1.63 kSps, and telemeters this data wirelessly to a base station. The companion base station transceiver includes an RF transmitter of +36 dBm (4 W) output power to wirelessly power the telemetry IC, and a digital receiver with a sensitivity of -70 dBm for 10⁻⁵ BER at 5.0 Mbps to receive the data stream from the telemetry IC. The telemetry chip was fabricated in a commercial 0.35 μ m 4M1P (4 metal, 1 poly) CMOS process. The die measures 2.36 × 1.88 mm, is 250 μm thick, and is wire bonded into a flex circuit assembly measuring 4.6 × 6.8 mm.
Bioactivity of Turmeric-Derived Curcuminoids and Related Metabolites in Breast Cancer
Wright, Laura E.; Frye, Jen B.; Gorti, Bhavana; Timmermann, Barbara N.; Funk, Janet L.
2013-01-01
While the chemotherapeutic effect of curcumin, one of three major curcuminoids derived from turmeric, has been reported, largely unexplored are the effects of complex turmeric extracts more analogous to traditional medicinal preparations, as well as the relative importance of the three curcuminoids and their metabolites as anti-cancer agents. These studies document the pharmacodynamic effects of chemically-complex turmeric extracts relative to curcuminoids on human breast cancer cell growth and tumor cell secretion of parathyroid hormone-related protein (PTHrP), an important driver of cancer bone metastasis. Finally, relative effects of structurally-related metabolites of curcuminoids were assessed on the same endpoints. We report that 3 curcuminoid-containing turmeric extracts differing with respect to the inclusion of additional naturally occurring chemicals (essential oils and/or polar compounds) were equipotent in inhibiting human breast cancer MDA-MB-231 cell growth (IC50=10–16μg/mL) and secretion of osteolytic PTHrP (IC50=2–3μg/mL) when concentrations were normalized to curcuminoid content. Moreover, these effects were curcuminoid-specific, as botanically-related gingerol containing extracts had no effect. While curcumin and bis-demethoxycurcumin were equipotent to each other and to the naturally occurring curcuminoid mixture (IC50=58 μM), demethoxycurcumin was without effect on cell growth. However, each of the individual curcuminoids inhibited PTHrP secretion (IC50=22–31μM) to the same degree as the curcuminoid mixture (IC50=16 μM). Degradative curcuminoid metabolites (vanillin and ferulic acid) did not inhibit cell growth or PTHrP, while reduced metabolites (tetrahydrocurcuminoids) had inhibitory effects on cell growth and PTHrP secretion but only at concentrations ≥10-fold higher than the curcuminoids. These studies emphasize the structural and biological importance of curcuminoids in the anti-breast cancer effects of turmeric and contradict recent assertions that certain of the curcuminoid metabolites studied here mediate these anti-cancer effects. PMID:23448448
1982-06-01
no other. is the field of computer grapnIcs expanded, such limitations became a real liability. The inability to use one program at more tnan one...terms of these environmental factors. For example, some programs may be portable from one device to another as long as the computing environment is not...PemPOMMIN OROANI&ATIO NAMI AND A00RESS IQ. PROGRAM CLEMENT. PROJECT. TASK AREA a WORK UNiT muN9ERS Naval Postgraduate School Monterey, California 93940
3-D Extensions for Trustworthy Systems
2011-01-01
LIMITATION OF ABSTRACT Same as Report (SAR) 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE PERSON a. REPORT unclassified b . ABSTRACT unclassified...we order the classes (TS ≥ S ≥ C ≥ U) and allow a flow from class A to class B only if B ≥ A [3]. TS C S U Fig. 7. Top view of a hypothetical multi...enclosure of the package. A more thorough discussion of the axioms of self-protection and dependency layering is applied to 3-D IC design in [8]. B
Shehab, Nadine; Brown, Megan N.; Kallen, Alexander J.; Perz, Joseph F.
2015-01-01
Objectives Pharmacy-compounded sterile preparations (P-CSPs) are frequently relied upon in U.S. healthcare, but are increasingly being linked to outbreaks of infections. We provide an updated overview of outbreak burden and characteristics, identify drivers of P-CSP demand, and discuss public health and patient safety lessons learned to help inform prevention. Methods Outbreaks of infections linked to contaminated P-CSPs that occurred between January 1, 2001 and December 31, 2013 were identified from internal Centers for Disease Control and Prevention reports, Food and Drug Administration drug safety communications, and published literature. Results We identified 19 outbreaks linked to P-CSPs, resulting in at least 1000 cases, including deaths. Outbreaks were reported across two-thirds of states, with almost one-half (8/19) involving cases in more than one state. Almost one-half of outbreaks were linked to injectable steroids (5/19) and intraocular bevacizumab (3/19). Non-patient-specific compounding originating from non-sterile ingredients and re-packaging of already sterile products were the most common practices associated with P-CSP contamination. Breaches in aseptic processing and deficiencies in sterilization procedures or in sterility/endotoxin testing were consistent findings. Hospital outsourcing, preference for variations of commercially available products, commercial drug shortages, and lower prices were drivers of P-CSP demand. Conclusions Recognized outbreaks linked to P-CSPs have been most commonly associated with non-patient-specific re-packaging and non-sterile to sterile compounding, and linked to lack of adherence to sterile compounding standards. Recently-enhanced regulatory oversight of compounding may improve adherence to such standards. Additional measures to limit and control these outbreaks include vigilance when outsourcing P-CSPs, scrutiny of drivers for P-CSP demand, and early recognition and notification of possible outbreaks. PMID:26001553
Wang, Likun; Yang, Luhe; Peng, Zuohan; Lu, Dan; Jin, Yan; McNutt, Michael; Yin, Yuxin
2015-01-01
With the burgeoning development of cloud technology and services, there are an increasing number of users who prefer cloud to run their applications. All software and associated data are hosted on the cloud, allowing users to access them via a web browser from any computer, anywhere. This paper presents cisPath, an R/Bioconductor package deployed on cloud servers for client users to visualize, manage, and share functional protein interaction networks. With this R package, users can easily integrate downloaded protein-protein interaction information from different online databases with private data to construct new and personalized interaction networks. Additional functions allow users to generate specific networks based on private databases. Since the results produced with the use of this package are in the form of web pages, cloud users can easily view and edit the network graphs via the browser, using a mouse or touch screen, without the need to download them to a local computer. This package can also be installed and run on a local desktop computer. Depending on user preference, results can be publicized or shared by uploading to a web server or cloud driver, allowing other users to directly access results via a web browser. This package can be installed and run on a variety of platforms. Since all network views are shown in web pages, such package is particularly useful for cloud users. The easy installation and operation is an attractive quality for R beginners and users with no previous experience with cloud services.
2015-01-01
Background With the burgeoning development of cloud technology and services, there are an increasing number of users who prefer cloud to run their applications. All software and associated data are hosted on the cloud, allowing users to access them via a web browser from any computer, anywhere. This paper presents cisPath, an R/Bioconductor package deployed on cloud servers for client users to visualize, manage, and share functional protein interaction networks. Results With this R package, users can easily integrate downloaded protein-protein interaction information from different online databases with private data to construct new and personalized interaction networks. Additional functions allow users to generate specific networks based on private databases. Since the results produced with the use of this package are in the form of web pages, cloud users can easily view and edit the network graphs via the browser, using a mouse or touch screen, without the need to download them to a local computer. This package can also be installed and run on a local desktop computer. Depending on user preference, results can be publicized or shared by uploading to a web server or cloud driver, allowing other users to directly access results via a web browser. Conclusions This package can be installed and run on a variety of platforms. Since all network views are shown in web pages, such package is particularly useful for cloud users. The easy installation and operation is an attractive quality for R beginners and users with no previous experience with cloud services. PMID:25708840
NASA Technical Reports Server (NTRS)
Johnson, Charles S.
1986-01-01
The embedded systems running real-time applications, for which Ada was designed, require their own mechanisms for the management of dynamically allocated storage. There is a need for packages which manage their own internalo structures to control their deallocation as well, due to the performance implications of garbage collection by the KAPSE. This places a requirement upon the design of generic packages which manage generically structured private types built-up from application-defined input types. These kinds of generic packages should figure greatly in the development of lower-level software such as operating systems, schedulers, controllers, and device driver; and will manage structures such as queues, stacks, link-lists, files, and binary multary (hierarchical) trees. Controlled to prevent inadvertent de-designation of dynamic elements, which is implicit in the assignment operation A study was made of the use of limited private type, in solving the problems of controlling the accumulation of anonymous, detached objects in running systems. The use of deallocator prodecures for run-down of application-defined input types during deallocation operations during satellites.
NASA Astrophysics Data System (ADS)
Marraccini, Philip J.; Jezzini, Moises A.; Peters, Frank H.
2016-05-01
Designing photonic integrated circuits (PICs) with packaging in mind is important since this impacts the performance of the final product. In coherent optical communication applications there are a large number of DC and RF lines that need routed to connect the PIC to the outer packaging. These RF lines should be impedance matched to the devices, isolated from each other, low loss and protected against electromagnetic interference (EMI) over the frequency range of interest to achieve the performance required for the application. Multilevel low temperature co-fired ceramic (LTCC) boards can be used as a carrier board connecting the PIC to the packaging due to its good RF performance, machinability, compatibility with hermetic sealing, and ability to integrate drivers into the board. Flexibility with layer numbers enables additional layers for shielding against electromagnetic interference or increased space for routing electrical connections. In this paper the design, simulations, and measured results for a set of 4 phase matched transmission lines in LTCC that would be used with an IQ MZM are presented. The measured 3dB bandwidth for a set of four phase matched transmission lines for an IQ MZM was measured to be 19.8 GHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albert G. Baca; Edwin J. Heller; Gregory C. Frye-Mason
High sensitivity acoustic wave chemical microsensors are being developed on GaAs substrates. These devices take advantage of the piezoelectric properties of GaAs as well as its mature microelectronics fabrication technology and nascent micromachining technology. The design, fabrication, and response of GaAs SAW chemical microsensors are reported. Functional integrated GaAs SAW oscillators, suitable for chemical sensing, have been produced. The integrated oscillator requires 20 mA at 3 VK, operates at frequencies up to 500 MHz, and occupies approximately 2 mmz. Discrete GaAs sensor components, including IC amplifiers, SAW delay lines, and IC phase comparators have been fabricated and tested. A temperaturemore » compensation scheme has been developed that overcomes the large temperature dependence of GaAs acoustic wave devices. Packaging issues related to bonding miniature flow channels directly to the GaAs substrates have been resolved. Micromachining techniques for fabricating FPW and TSM microsensors on thin GaAs membranes are presented and GaAs FPW delay line performance is described. These devices have potentially higher sensitivity than existing GaAs and quartz SAW sensors.« less
The QSAR study of flavonoid-metal complexes scavenging rad OH free radical
NASA Astrophysics Data System (ADS)
Wang, Bo-chu; Qian, Jun-zhen; Fan, Ying; Tan, Jun
2014-10-01
Flavonoid-metal complexes have antioxidant activities. However, quantitative structure-activity relationships (QSAR) of flavonoid-metal complexes and their antioxidant activities has still not been tackled. On the basis of 21 structures of flavonoid-metal complexes and their antioxidant activities for scavenging rad OH free radical, we optimised their structures using Gaussian 03 software package and we subsequently calculated and chose 18 quantum chemistry descriptors such as dipole, charge and energy. Then we chose several quantum chemistry descriptors that are very important to the IC50 of flavonoid-metal complexes for scavenging rad OH free radical through method of stepwise linear regression, Meanwhile we obtained 4 new variables through the principal component analysis. Finally, we built the QSAR models based on those important quantum chemistry descriptors and the 4 new variables as the independent variables and the IC50 as the dependent variable using an Artificial Neural Network (ANN), and we validated the two models using experimental data. These results show that the two models in this paper are reliable and predictable.
The EPOS Vision for the Open Science Cloud
NASA Astrophysics Data System (ADS)
Jeffery, Keith; Harrison, Matt; Cocco, Massimo
2016-04-01
Cloud computing offers dynamic elastic scalability for data processing on demand. For much research activity, demand for computing is uneven over time and so CLOUD computing offers both cost-effectiveness and capacity advantages. However, as reported repeatedly by the EC Cloud Expert Group, there are barriers to the uptake of Cloud Computing: (1) security and privacy; (2) interoperability (avoidance of lock-in); (3) lack of appropriate systems development environments for application programmers to characterise their applications to allow CLOUD middleware to optimize their deployment and execution. From CERN, the Helix-Nebula group has proposed the architecture for the European Open Science Cloud. They are discussing with other e-Infrastructure groups such as EGI (GRIDs), EUDAT (data curation), AARC (network authentication and authorisation) and also with the EIROFORUM group of 'international treaty' RIs (Research Infrastructures) and the ESFRI (European Strategic Forum for Research Infrastructures) RIs including EPOS. Many of these RIs are either e-RIs (electronic-RIs) or have an e-RI interface for access and use. The EPOS architecture is centred on a portal: ICS (Integrated Core Services). The architectural design already allows for access to e-RIs (which may include any or all of data, software, users and resources such as computers or instruments). Those within any one domain (subject area) of EPOS are considered within the TCS (Thematic Core Services). Those outside, or available across multiple domains of EPOS, are ICS-d (Integrated Core Services-Distributed) since the intention is that they will be used by any or all of the TCS via the ICS. Another such service type is CES (Computational Earth Science); effectively an ICS-d specializing in high performance computation, analytics, simulation or visualization offered by a TCS for others to use. Already discussions are underway between EPOS and EGI, EUDAT, AARC and Helix-Nebula for those offerings to be considered as ICS-ds by EPOS.. Provision of access to ICS-Ds from ICS-C concerns several aspects: (a) Technical : it may be more or less difficult to connect and pass from ICS-C to the ICS-d/ CES the 'package' (probably a virtual machine) of data and software; (b) Security/privacy : including passing personal information e.g. related to AAAI (Authentication, authorization, accounting Infrastructure); (c) financial and legal : such as payment, licence conditions; Appropriate interfaces from ICS-C to ICS-d are being designed to accommodate these aspects. The Open Science Cloud is timely because it provides a framework to discuss governance and sustainability for computational resource provision as well as an effective interpretation of federated approach to HPC(High Performance Computing) -HTC (High Throughput Computing). It will be a unique opportunity to share and adopt procurement policies to provide access to computational resources for RIs. The current state of discussions and expected roadmap for the EPOS-Open Science Cloud relationship are presented.
The economics of robotic cystectomy: cost comparison of open versus robotic cystectomy.
Lee, Richard; Ng, Casey K; Shariat, Shahrokh F; Borkina, Anna; Guimento, Robert; Brumit, Kevin F; Scherr, Douglas S
2011-12-01
• To assess and compare the economic burden of open radical cystectomy (OC) vs robotic-assisted laparoscopic radical cystectomy (RC) with pelvic lymph node dissection and urinary diversion. • A series of 103 and 83 consecutive patients undergoing OC and RC, respectively, were prospectively studied at a tertiary care institution from April 2002 to February 2009. • Data were collected on patient demographics, perioperative parameters and length of stay (LOS) in hospital. Cohorts were subdivided into ileal conduit (IC), continent cutaneous diversion (CCD) and orthotopic neobladder (ON) subgroups. • A linear cost model was created to simulate treatment with OC vs RC. Procedural costs were derived from the Medicare Resource Based Relative Value Scale. Materials costs were obtained from the respective suppliers. The indirect costs of complications were considered. • Sensitivity analyses were performed. • Despite a higher cost of materials, RC was less expensive than OC for IC and CCD, although the cost advantage deteriorated for ON. • The per-case costs of RC with IC, CCD and ON were $20,659, $22,102 and $22,685, respectively, compared to $25,505, $22,697 and $20,719 for their OC counterparts. • The largest cost driver in the study was LOS in hospital. • RC showed a shorter LOS compared to OC, although this effect was insufficient to offset the higher cost of robotic surgery. • Complications materially affected cost performance. • Despite a higher cost of materials, RC can be more cost efficient than OC as a treatment for bladder cancer at a high-volume, tertiary care referral centre, particularly with IC. • Complications significantly impact cost performance. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
A Study of Direct Digital Manufactured RF/Microwave Packaging
NASA Astrophysics Data System (ADS)
Stratton, John W. I.
Various facets of direct digital manufactured (DDM) microwave packages are studied. The rippled surface inherent in fused deposition modeling (FDM) fabricated geometries is modeled in Ansoft HFSS, and its effect on the performance of microstrip transmission lines is assessed via simulation and measurement. The thermal response of DDM microstrip transmission lines is analyzed over a range of RF input powers, and linearity is confirmed over that range. Two IC packages are embedded into DDM printed circuit boards, and their performance is analyzed. The first is a low power RF switch, and the second is an RF front end device that includes a low noise amplifier (LNA) and a power amplifier (PA). The RF switch is shown to perform well, as compared to a layout designed for a Rogers 4003C microwave laminate substrate. The LNA performs within datasheet specifications. The power amplifier generates substantial heat, so a thermal management attempt is described. Finally, a capacitively loaded 6dB Wilkinson power divider is designed and fabricated using DDM techniques and materials. Its performance is analyzed and compared to simulation. The device is shown to compare favorably to a similar device fabricated on a Rogers 4003C microwave laminate using traditional printed circuit board techniques.
Access to CAMAC from VxWorks and UNIX in DART
DOE Office of Scientific and Technical Information (OSTI.GOV)
Streets, J.; Meadows, J.; Moore, C.
1995-05-01
As part of the DART Project the authors have developed a package of software for CAMAC access from UNIX and VxWorks platforms, with support for several hardware interfaces. They report on developments for the CES CBD8210 VME to parallel CAMAC, the Hytec VSD2992 VME to serial CAMAC and Jorway 411S SCSI to parallel and serial CAMAC branch drivers, and give a summary of the timings obtained.
Fischer, M; Tuzson, B; Hugi, A; Brönnimann, R; Kunz, A; Blaser, S; Rochat, M; Landry, O; Müller, A; Emmenegger, L
2014-03-24
Intermittent scanning for continuous-wave quantum cascade lasers is proposed along with a custom-built laser driver optimized for such operation. This approach lowers the overall heat dissipation of the laser by dropping its drive current to zero between individual scans and holding a longer pause between scans. This allows packaging cw-QCLs in TO–3 housings with built-in collimating optics, thus reducing cost and footprint of the device. The fully integrated, largely analog, yet flexible laser driver eliminates the need for any external electronics for current modulation, lowers the demands on power supply performance, and allows shaping of the tuning current in a wide range. Optimized ramp shape selection leads to large and nearly linear frequency tuning (>1.5 cm−1). Experimental characterization of the proposed scheme with a QCL emitting at 7.7 μm gave a frequency stability of 3.2×10−5 cm−1 for the laser emission, while a temperature dependence of 2.3×10−4 cm−1/K was observed when the driver electronics was exposed to sudden temperature changes. We show that these characteristics make the driver suitable for high precision trace gas measurements by analyzing methane absorption lines in the respective spectral region.
Space station WP-04 power system preliminary analysis and design document, volume 3
NASA Technical Reports Server (NTRS)
1986-01-01
Rocketdyne plans to generate a system level specification for the Space Station Electric Power System (EPS) in order to facilitate the usage, accountability, and tracking of overall system level requirements. The origins and status of the verification planning effort are traced and an overview of the Space Station program interactions are provided. The work package level interfaces between the EPS and the other Space Station work packages are outlined. A trade study was performed to determine the peaking split between PV and SD, and specifically to compare the inherent total peaking capability with proportionally shared peaking. In order to determine EPS cost drivers for the previous submittal of DRO2, the life cycle cost (LCC) model was run to identify the more significant costs and the factors contributing to them.
Wide-Field Imaging Telescope-0 (WIT0) with automatic observing system
NASA Astrophysics Data System (ADS)
Ji, Tae-Geun; Byeon, Seoyeon; Lee, Hye-In; Park, Woojin; Lee, Sang-Yun; Hwang, Sungyong; Choi, Changsu; Gibson, Coyne Andrew; Kuehne, John W.; Prochaska, Travis; Marshall, Jennifer L.; Im, Myungshin; Pak, Soojong
2018-01-01
We introduce Wide-Field Imaging Telescope-0 (WIT0), with an automatic observing system. It is developed for monitoring the variabilities of many sources at a time, e.g. young stellar objects and active galactic nuclei. It can also find the locations of transient sources such as a supernova or gamma-ray bursts. In 2017 February, we installed the wide-field 10-inch telescope (Takahashi CCA-250) as a piggyback system on the 30-inch telescope at the McDonald Observatory in Texas, US. The 10-inch telescope has a 2.35 × 2.35 deg field-of-view with a 4k × 4k CCD Camera (FLI ML16803). To improve the observational efficiency of the system, we developed a new automatic observing software, KAOS30 (KHU Automatic Observing Software for McDonald 30-inch telescope), which was developed by Visual C++ on the basis of a windows operating system. The software consists of four control packages: the Telescope Control Package (TCP), the Data Acquisition Package (DAP), the Auto Focus Package (AFP), and the Script Mode Package (SMP). Since it also supports the instruments that are using the ASCOM driver, the additional hardware installations become quite simplified. We commissioned KAOS30 in 2017 August and are in the process of testing. Based on the WIT0 experiences, we will extend KAOS30 to control multiple telescopes in future projects.
Mohanta, Yugal K.; Panda, Sujogya K.; Bastia, Akshaya K.; Mohanta, Tapan K.
2017-01-01
Silver nanoparticles play an integral part in the evolution of new antimicrobials against the broad ranges of pathogenic microorganisms. Recently, biological synthesis of metal nanoparticles using plant extracts has been successfully consummated. In the present study, the biosynthesis of silver nanoparticles (AgNPs) was conducted using the leaf extract of plant Protium serratum, having novel ethnomedicinal. The synthesized AgNPs were characterized using UV-Visible spectroscopy, dynamic light scattering spectroscopy (DLS), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy. The DLS study revealed the surface charge of the resulted nanoparticles that was highly negative, i.e., −25.0 ± 7.84 mV and the size was 74.56 ± 0.46 nm. The phytochemical and FTIR analysis confirmed the role of water-soluble phyto-compounds for the reduction of silver ions to silver nanoparticles. The potential antibacterial activity of AgNPs was studied against the food borne pathogens viz. Pseudomonas aeruginosa (IC50 = 74.26 ± 0.14 μg/ml), Escherichia coli (IC50 = 84.28 ± 0.36 μg/ml), Bacillus subtilis (IC50 = 94.43 ± 0.4236 μg/ml). The in vitro antioxidant potential of AgNPs was evaluated using 1, 1-diphenyl-2-picryl-hydrazil (IC50 = 6.78 ± 0.15 μg/ml) and hydroxyl radical assay (IC50 = 89.58 ± 1.15 μg/ml). In addition, the cytotoxicity of AgNPs was performed against fibroblast cell line L-929 to evaluate their biocompatibility. The overall results of the present investigation displayed the potential use of P. serratum leaf extract as a good bio-resource for the biosynthesis of AgNPs and their implementation in diverse applications, specifically as antibacterial agent in food packaging and preservation to combat against various food borne pathogenic bacteria along with its pharmaceutical and biomedical applications. PMID:28458659
NASA Technical Reports Server (NTRS)
Patterson, Richard; Hammoud, Ahmad
2011-01-01
A new commercial-off-the-shelf (COTS) gate driver designed to drive both the high-side and the low-side enhancement-mode GaN FETs, National Semiconductor's type LM5113, was evaluated for operation at temperatures beyond its recommended specified limits of -40 C to +125 C. The effects of limited thermal cycling under the extended test temperature, which ranged from -194 C to +150 C, on the operation of this chip as well as restart capability at the extreme cryogenic and hot temperatures were also investigated. The driver circuit was able to maintain good operation throughout the entire test regime between -194 C and +150 C without undergoing any major changes in its outputs signals and characteristics. The limited thermal cycling performed on the device also had no effect on its performance, and the driver chip was able to successfully restart at each of the extreme temperatures of -194 C and +150 C. The plastic packaging of this device was also not affected by either the short extreme temperature exposure or the limited thermal cycling. These preliminary results indicate that this new commercial-off-the-shelf (COTS) halfbridge eGaN FET driver integrated circuit has the potential for use in space exploration missions under extreme temperature environments. Further testing is planned under long-term cycling to assess the reliability of these parts and to determine their suitability for extended use in the harsh environments of space.
On-Die Sensors for Transient Events
NASA Astrophysics Data System (ADS)
Suchak, Mihir Vimal
Failures caused by transient electromagnetic events like Electrostatic Discharge (ESD) are a major concern for embedded systems. The component often failing is an integrated circuit (IC). Determining which IC is affected in a multi-device system is a challenging task. Debugging errors often requires sophisticated lab setups which require intentionally disturbing and probing various parts of the system which might not be easily accessible. Opening the system and adding probes may change its response to the transient event, which further compounds the problem. On-die transient event sensors were developed that require relatively little area on die, making them inexpensive, they consume negligible static current, and do not interfere with normal operation of the IC. These circuits can be used to determine the pin involved and the level of the event in the event of a transient event affecting the IC, thus allowing the user to debug system-level transient events without modifying the system. The circuit and detection scheme design has been completed and verified in simulations with Cadence Virtuoso environment. Simulations accounted for the impact of the ESD protection circuits, parasitics from the I/O pin, package and I/O ring, and included a model of an ESD gun to test the circuit's response to an ESD pulse as specified in IEC 61000-4-2. Multiple detection schemes are proposed. The final detection scheme consists of an event detector and a level sensor. The event detector latches on the presence of an event at a pad, to determine on which pin an event occurred. The level sensor generates current proportional to the level of the event. This current is converted to a voltage and digitized at the A/D converter to be read by the microprocessor. Detection scheme shows good performance in simulations when checked against process variations and different kind of events.
Investigation into the development of computer aided design software for space based sensors
NASA Technical Reports Server (NTRS)
Pender, C. W.; Clark, W. L.
1987-01-01
The described effort is phase one of the development of a Computer Aided Design (CAD) software to be used to perform radiometric sensor design. The software package will be referred to as SCAD and is directed toward the preliminary phase of the design of space based sensor system. The approach being followed is to develop a modern, graphic intensive, user friendly software package using existing software as building blocks. The emphasis will be directed toward the development of a shell containing menus, smart defaults, and interfaces, which can accommodate a wide variety of existing application software packages. The shell will offer expected utilities such as graphics, tailored menus, and a variety of drivers for I/O devices. Following the development of the shell, the development of SCAD is planned as chiefly selection and integration of appropriate building blocks. The phase one development activities have included: the selection of hardware which will be used with SCAD; the determination of the scope of SCAD; the preliminary evaluation of a number of software packages for applicability to SCAD; determination of a method for achieving required capabilities where voids exist; and then establishing a strategy for binding the software modules into an easy to use tool kit.
Alternative technological development for RF hybridization
NASA Astrophysics Data System (ADS)
Antônio Finardi, Célio; da Fontoura Ponchet, André; Battesini Adamo, Cristina; Flacker, Alexander; Cotrin Teixeira, Ricardo; Panepucci, Roberto Ricardo
2017-03-01
The paper presents a technological solution for high frequency packaging platform evaluated up to 40 GHz. The main purpose of this development was to define an alternative hybrid technology that is more flexible and faster to prototype compared with thin film or multi chip module (MCM-D). The alternative technology also shows adequate performance for high bit rate solutions integrating optical and electronics blocks. This approach consists of a soft substrate (laminate material), plating processes (electroless Ni-P/Au, electrolytic Au) and lithography patterning. Ground coplanar waveguide was used for microwave structures with excellent ground planes connections due to easy via holes implementation. We present results of high frequency packaging of important RF blocks, such as integrated broadband bias-T, transimpedance amplifier ICs and silicon photonics optical modulators. The paper demonstrates a solution for high frequency hybridization that can be implemented with standard substrates, designed with any shape and with large numbers of metalized via holes and compatible with usual assembling techniques.
Hoff, Timothy; Hartmann, Christine W; Soerensen, Christina; Wroe, Peter; Dutta-Linn, Maya; Lee, Grace
2011-01-01
Healthcare-associated infections (HAIs) are among the most common adverse events in hospitals, and the morbidity and mortality associated with them are significant. In 2008, the Centers for Medicare and Medicaid Services (CMS) implemented a new financial policy that no longer provides payment to hospitals for services related to certain infections not present on admission and deemed preventable. At present, little is known about how this policy is being implemented in hospital settings. One key goal of the policy is for it to serve as a quality improvement driver within hospitals, providing the rationale and motivation for hospitals to engage in greater infection-related surveillance and prevention activities. This article examines the role organizational factors, such as leadership and culture, play in the effectiveness of the CMS policy as a quality improvement (QI) driver within hospital settings. Between late 2009 and early 2010, interviews were conducted with 36 infection preventionists working at a national sample of 36 hospitals. We found preliminary evidence that hospital executive behavior, a proactive infection control (IC) culture, and clinical staff engagement played a favorable role in enhancing the recognition, acceptance, and significance of the CMS policy as a QI driver within hospitals. We also found several other contextual factors that may impede the degree to which the above factors facilitate links between the CMS policy and hospital QI activities.
A rugged 650 V SOI-based high-voltage half-bridge IGBT gate driver IC for motor drive applications
NASA Astrophysics Data System (ADS)
Hua, Qing; Li, Zehong; Zhang, Bo; Chen, Weizhong; Huang, Xiangjun; Feng, Yuxiang
2015-05-01
This paper proposes a rugged high-voltage N-channel insulated gate bipolar transistor (IGBT) gate driver integrated circuit. The device integrates a high-side and a low-side output stages on a single chip, which is designed specifically for motor drive applications. High-voltage level shift technology enables the high-side stage of this device to operate up to 650 V. The logic inputs are complementary metal oxide semiconductor (CMOS)/transistor transistor logic compatible down to 3.3 V. Undervoltage protection functionality with hysteresis characteristic has also been integrated to enhance the device reliability. The device is fabricated in a 1.0 μm, 650 V high-voltage bipolar CMOS double-diffused metal oxide semiconductor (BCD) on silicon-on-insulator (SOI) process. Deep trench dielectric isolation technology is employed to provide complete electrical isolation with advantages such as reduced parasitic effects, excellent noise immunity and low leakage current. Experimental results show that the isolation voltage of this device can be up to approximately 779 V at 25°C, and the leakage current is only 5 nA at 650 V, which is 15% higher and 67% lower than the conventional ones. In addition, it delivers an excellent thermal stability and needs very low quiescent current and offers a high gate driver capability which is needed to adequately drive IGBTs that have large input capacitances.
NASA Technical Reports Server (NTRS)
Dumas, Joseph D., II
1998-01-01
Several virtual reality I/O peripherals were successfully configured and integrated as part of the author's 1997 Summer Faculty Fellowship work. These devices, which were not supported by the developers of VR software packages, use new software drivers and configuration files developed by the author to allow them to be used with simulations developed using those software packages. The successful integration of these devices has added significant capability to the ANVIL lab at MSFC. In addition, the author was able to complete the integration of a networked virtual reality simulation of the Space Shuttle Remote Manipulator System docking Space Station modules which was begun as part of his 1996 Fellowship. The successful integration of this simulation demonstrates the feasibility of using VR technology for ground-based training as well as on-orbit operations.
Yung, Lai Chin; Fei, Cheong Choke; Mandeep, JS; Binti Abdullah, Huda; Wee, Lai Khin
2014-01-01
The success of printing technology in the electronics industry primarily depends on the availability of metal printing ink. Various types of commercially available metal ink are widely used in different industries such as the solar cell, radio frequency identification (RFID) and light emitting diode (LED) industries, with limited usage in semiconductor packaging. The use of printed ink in semiconductor IC packaging is limited by several factors such as poor electrical performance and mechanical strength. Poor adhesion of the printed metal track to the epoxy molding compound is another critical factor that has caused a decline in interest in the application of printing technology to the semiconductor industry. In this study, two different groups of adhesion promoters, based on metal and polymer groups, were used to promote adhesion between the printed ink and the epoxy molding substrate. The experimental data show that silver ink with a metal oxide adhesion promoter adheres better than silver ink with a polymer adhesion promoter. This result can be explained by the hydroxyl bonding between the metal oxide promoter and the silane grouping agent on the epoxy substrate, which contributes a greater adhesion strength compared to the polymer adhesion promoter. Hypotheses of the physical and chemical functions of both adhesion promoters are described in detail. PMID:24830317
Yung, Lai Chin; Fei, Cheong Choke; Mandeep, Js; Binti Abdullah, Huda; Wee, Lai Khin
2014-01-01
The success of printing technology in the electronics industry primarily depends on the availability of metal printing ink. Various types of commercially available metal ink are widely used in different industries such as the solar cell, radio frequency identification (RFID) and light emitting diode (LED) industries, with limited usage in semiconductor packaging. The use of printed ink in semiconductor IC packaging is limited by several factors such as poor electrical performance and mechanical strength. Poor adhesion of the printed metal track to the epoxy molding compound is another critical factor that has caused a decline in interest in the application of printing technology to the semiconductor industry. In this study, two different groups of adhesion promoters, based on metal and polymer groups, were used to promote adhesion between the printed ink and the epoxy molding substrate. The experimental data show that silver ink with a metal oxide adhesion promoter adheres better than silver ink with a polymer adhesion promoter. This result can be explained by the hydroxyl bonding between the metal oxide promoter and the silane grouping agent on the epoxy substrate, which contributes a greater adhesion strength compared to the polymer adhesion promoter. Hypotheses of the physical and chemical functions of both adhesion promoters are described in detail.
Psychosocial Risk Factors for Low Back Pain and Absenteeism among Slovenian Professional Drivers.
Kresal, Friderika; Suklan, Jana; Roblek, Vasja; Jerman, Andrej; Meško, Maja
2017-06-01
The aim of this study was to determine the most common psychosocial risk factors for absenteeism and the extent to which low back pain occurs among Slovenian professional drivers as result of various psychosocial risk factors. The study involved 275 professional drivers, mostly men (mean age 41.6 years). Statistical data analysis was conducted using SPSS package version 21, MS Excel version 2007 and Pajek, version 3. The main method for data processing was regression analysis. The results of the quantitative survey showed that lower back pain is mostly caused by lifting and carrying heavy loads, inadequate working conditions, poor physical fitness, regular nights out, shift work, and stress. Dissatisfaction with work, shift work and unsuitable working conditions significantly affect the incidence of low back pain. Absenteeism is influenced by factors such as dissatisfaction at work, disrespectful attitude of managers, unsuitable working conditions, personal dissatisfaction, lack of understanding of the partner, and enjoying nightlife on a regular basis. The study clarifies the unexplained holistic psychosocial risk factors and treatment effects on health in the population of professional drivers. Such factors can lead to absenteeism. The study also provides initial demonstration research in the Slovenian practice. Furthermore, it provides solutions in a holistic approach to solve the problem of risk factors management. Copyright© by the National Institute of Public Health, Prague 2017
NASA Astrophysics Data System (ADS)
Zhong, Y.; Zhao, N.; Liu, C. Y.; Dong, W.; Qiao, Y. Y.; Wang, Y. P.; Ma, H. T.
2017-11-01
As the diameter of solder interconnects in three-dimensional integrated circuits (3D ICs) downsizes to several microns, how to achieve a uniform microstructure with thousands of interconnects on stacking chips becomes a critical issue in 3D IC manufacturing. We report a promising way for fabricating fully intermetallic interconnects with a regular grain morphology and a strong texture feature by soldering single crystal (111) Cu/Sn/polycrystalline Cu interconnects under the temperature gradient. Continuous epitaxial growth of η-Cu6Sn5 at cold end liquid-Sn/(111)Cu interfaces has been demonstrated. The resultant η-Cu6Sn5 grains show faceted prism textures with an intersecting angle of 60° and highly preferred orientation with their ⟨ 11 2 ¯ 0 ⟩ directions nearly paralleling to the direction of the temperature gradient. These desirable textures are maintained even after soldering for 120 min. The results pave the way for controlling the morphology and orientation of interfacial intermetallics in 3D packaging technologies.
Access to CAMAC from VxWorks and UNIX in DART
NASA Astrophysics Data System (ADS)
Streets, J.; Meadows, J.; Moore, C.; Pordes, R.; Slimmer, D.; Vittone, M.; Stern, E.
1996-02-01
As part of the DART Project [Data acquisition for the next Generation Fermilab Fixed Target Experiments] we have developed a package of software for CAMAC access from UNIX and VxWorks platforms, with support for several hardware interfaces. We report on developments for the CES CBD8210 VME to parallel CAMAC, the Hytec VSD2992 VME to serial CAMAC and Jorway 411s SCSI to parallel and serial CAMAC branch drivers, and give a summary of the timings obtained.
1981-12-01
occurred on the Introversion Scale of the NMPI. 20 A review of the use of psychological tests on MT’s was accomplished by Driver and Feeley [1974...programs, Gondek [1981] has recommended that the best pro- cedure for variable inclusion when using a stepwise procedure is to use the threshold default...values supplied by the package, since no simple rules exist for determining entry or removal thresholds for partial F’s, tolerance statistics, or any of
Variable Depth Bragg Peak Method for Single Event Effects Testing
NASA Technical Reports Server (NTRS)
Buchner, S.; Kanyogoro, N.; Foster, C.; O'Neill, P.
2011-01-01
Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.
Beld, Marcel; Minnaar, René; Weel, Jan; Sol, Cees; Damen, Marjolein; van der Avoort, Harry; Wertheim-van Dillen, Pauline; Breda, Alex van; Boom, René
2004-01-01
The objective of the present study was the development of a diagnostic reverse transcription (RT)-PCR for the specific detection of enterovirus (EV) RNA in clinical specimens controlled by an internal control (IC) RNA. The IC RNA contains the same primer binding sites as EV RNA but has a different probe region. The IC RNA was packaged into an MS2 phage core particle (armored) and was added to the clinical sample to allow monitoring of both extraction efficiency and RT-PCR efficiency. Serial dilutions of the IC RNA were made, and the detection limit of the RT-PCR was tested in a background of EV RNA-negative cerebrospinal fluid. The sensitivity and specificity of the RT-PCR assay were tested by using all 64 known EV serotypes, several non-EV serotypes, and two Quality Control for Molecular Diagnostics (QCMD) Program EV proficiency panels from 2001 and 2002. In total, 322 clinical specimens were tested by RT-PCR, and to establish the clinical utility of the RT-PCR, a comparison of the results of viral culture and RT-PCR was done with 87 clinical specimens. The lower limit of sensitivity was reached at about 150 copies of IC RNA/ml. All 64 EV serotypes were positive, while all non-EV serotypes were negative. All culture-positive samples of the 2001 QCMD proficiency panel (according to the 50% tissue culture infective doses per milliliter) were positive by RT-PCR. Invalid results, i.e., negativity for both EV RNA and IC RNA, due to inhibition of RT-PCR were observed for 33.3% of the members of the 2002 QCMD proficiency panel and 3.1% of the clinical specimens. Inhibition of RT-PCR could be relieved by the addition of 400 ng of bovine α-casein per μl to both the RT reaction mixture and the PCR mixture. With this optimized protocol, the results for all samples of the 2002 QCMD proficiency panel and all clinical specimens except one fecal sample (0.3%) were valid. Evaluation of the clinical samples demonstrated that EV infection could be detected in 12 of 87 samples (13.8%) by RT-PCR, while viral culture was negative. Our data show that the RT-PCR with armored IC RNA offers a very reliable and rapid diagnostic tool for the detection of EV in clinical specimens and that the addition of bovine α-casein relieved inhibition of the RT-PCR for 99.7% of clinical specimens. PMID:15243060
Single-mode glass waveguide technology for optical interchip communication on board level
NASA Astrophysics Data System (ADS)
Brusberg, Lars; Neitz, Marcel; Schröder, Henning
2012-01-01
The large bandwidth demand in long-distance telecom networks lead to single-mode fiber interconnects as result of low dispersion, low loss and dense wavelength multiplexing possibilities. In contrast, multi-mode interconnects are suitable for much shorter lengths up to 300 meters and are promising for optical links between racks and on board level. Active optical cables based on multi-mode fiber links are at the market and research in multi-mode waveguide integration on board level is still going on. Compared to multi-mode, a single-mode waveguide has much more integration potential because of core diameters of around 20% of a multi-mode waveguide by a much larger bandwidth. But light coupling in single-mode waveguides is much more challenging because of lower coupling tolerances. Together with the silicon photonics technology, a single-mode waveguide technology on board-level will be the straight forward development goal for chip-to-chip optical interconnects integration. Such a hybrid packaging platform providing 3D optical single-mode links bridges the gap between novel photonic integrated circuits and the glass fiber based long-distance telecom networks. Following we introduce our 3D photonic packaging approach based on thin glass substrates with planar integrated optical single-mode waveguides for fiber-to-chip and chip-to-chip interconnects. This novel packaging approach merges micro-system packaging and glass integrated optics. It consists of a thin glass substrate with planar integrated singlemode waveguide circuits, optical mirrors and lenses providing an integration platform for photonic IC assembly and optical fiber interconnect. Thin glass is commercially available in panel and wafer formats and characterizes excellent optical and high-frequency properties. That makes it perfect for microsystem packaging. The paper presents recent results in single-mode waveguide technology on wafer level and waveguide characterization. Furthermore the integration in a hybrid packaging process and design issues are discussed.
Low-cost thermo-electric infrared FPAs and their automotive applications
NASA Astrophysics Data System (ADS)
Hirota, Masaki; Ohta, Yoshimi; Fukuyama, Yasuhiro
2008-04-01
This paper describes three low-cost infrared focal plane arrays (FPAs) having a 1,536, 2,304, and 10,800 elements and experimental vehicle systems. They have a low-cost potential because each element consists of p-n polysilicon thermocouples, which allows the use of low-cost ultra-fine microfabrication technology commonly employed in the conventional semiconductor manufacturing processes. To increase the responsivity of FPA, we have developed a precisely patterned Au-black absorber that has high infrared absorptivity of more than 90%. The FPA having a 2,304 elements achieved high resposivity of 4,300 V/W. In order to reduce package cost, we developed a vacuum-sealed package integrated with a molded ZnS lens. The camera aiming the temperature measurement of a passenger cabin is compact and light weight devices that measures 45 x 45 x 30 mm and weighs 190 g. The camera achieves a noise equivalent temperature deviation (NETD) of less than 0.7°C from 0 to 40°C. In this paper, we also present a several experimental systems that use infrared cameras. One experimental system is a blind spot pedestrian warning system that employs four infrared cameras. It can detect the infrared radiation emitted from a human body and alerts the driver when a pedestrian is in a blind spot. The system can also prevent the vehicle from moving in the direction of the pedestrian. Another system uses a visible-light camera and infrared sensors to detect the presence of a pedestrian in a rear blind spot and alerts the driver. The third system is a new type of human-machine interface system that enables the driver to control the car's audio system without letting go of the steering wheel. Uncooled infrared cameras are still costly, which limits their automotive use to high-end luxury cars at present. To promote widespread use of IR imaging sensors on vehicles, we need to reduce their cost further.
Mallikarjun, Sajjanshetty; Rao, Ashwini; Rajesh, Gururaghavendran; Shenoy, Ramya; Bh, Mithun Pai
2014-01-01
Smoking tobacco is considered as a leading cause of preventable death, mostly in developing countries like India. One of the primary goals of international tobacco control is to educate smokers about the risks associated with tobacco consumption. Tobacco warning labels (TWLs) on cigarette packages are one of the most common statutory means to communicate health risks of smoking to smokers, with the hope that once educated, they will be more likely to quit the habit. The present survey was conducted to assess the effectiveness of TWLs in communicating health risks of tobacco usage among 263 adult smokers working as bus drivers in Karnataka State Road Transport Corporation (KSRTC), Mangalore, India. Information was collected on demographic details, exposure and response to health warnings on tobacco products, intention to quit and nicotine dependency. The majority (79.5%) of the respondents revealed negative intentions towards quitting smoking. Nearly half of the participants had a 'low' nicotine dependency (47.5%) and 98.1% of the respondents had often noticed warning labels on tobacco packages. These health warnings made 71.5% of the respondents think about quitting smoking. Respondents who noticed advertisement or pictures about dangers of smoking had better knowledge, with respect to lung cancer and impotence as a consequence of tobacco. A higher exposure to warning labels was significantly associated with lower nicotine dependency levels of smokers among the present study population. A significantly higher number of respondents who noticed advertisement or pictures about the dangers of smoking thought about the risks of smoking and were more inclined to think about quitting smoking. As exposure increased, an increase in the knowledge and response of participants was also observed. Exposure to tobacco warning labels helps to educate smokers about health risks of tobacco smoking. It may be possible to promote oral health among bus drivers by developing strategies to educate them about these risk factors.
GEMPAK 5.1 - A GENERAL METEOROLOGICAL PACKAGE (UNIX VERSION)
NASA Technical Reports Server (NTRS)
Desjardins, M. L.
1994-01-01
GEMPAK is a general meteorological software package developed at NASA/Goddard Space Flight Center. It includes programs to analyze and display surface, upper-air, and gridded data, including model output. There are very general programs to list, edit, and plot data on maps, to display profiles and time series, to draw and fill contours, to draw streamlines, to plot symbols for clouds, sky cover, and pressure tendency, and draw cross sections in the case of gridded data and sounding data. In addition, there are Barnes objective analysis programs to grid surface and upper-air data. The programs include the capabilities to derive meteorological parameters from those found in the dataset, to perform vertical interpolations of sounding data to different coordinate systems, and to compute an extensive set of gridded diagnostic quantities by specifying various nested combinations of scalars and vector arithmetic, algebraic, and differential operators. The GEMPAK 5.1 graphics/transformation subsystem, GEMPLT, provides device-independent graphics. GEMPLT also has the capability to display output in a variety of map projections or overlaid on satellite imagery. GEMPAK 5.1 is written in FORTRAN 77 and C-language and has been implemented on VAX computers under VMS and on computers running the UNIX operating system. During installation and normal use, this package occupies approximately 100Mb of hard disk space. The UNIX version of GEMPAK includes drivers for several graphic output systems including MIT's X Window System (X11,R4), Sun GKS, PostScript (color and monochrome), Silicon Graphics, and others. The VMS version of GEMPAK also includes drivers for several graphic output systems including PostScript (color and monochrome). The VMS version is delivered with the object code for the Transportable Applications Environment (TAE) program, version 4.1 which serves as a user interface. A color monitor is recommended for displaying maps on video display devices. Data for rendering regional maps is included with this package. The standard distribution medium for the UNIX version of GEMPAK 5.1 is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the VMS version of GEMPAK 5.1 is a 6250 BPI 9-track magnetic tape in DEC VAX BACKUP format. The VMS version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. This program was developed in 1985. The current version, GEMPAK 5.1, was released in 1992. The package is delivered with source code. An extensive collection of subroutine libraries allows users to format data for use by GEMPAK, to develop new programs, and to enhance existing ones.
PSTOOLS - FOUR PROGRAMS THAT INTERPRET/FORMAT POSTSCRIPT FILES
NASA Technical Reports Server (NTRS)
Choi, D.
1994-01-01
PSTOOLS is a package of four programs that operate on files written in the page description language, PostScript. The programs include a PostScript previewer for the IRIS workstation, a PostScript driver for the Matrix QCRZ film recorder, a PostScript driver for the Tektronix 4693D printer, and a PostScript code beautifier that formats PostScript files to be more legible. The three programs PSIRIS, PSMATRIX, and PSTEK are similar in that they all interpret the PostScript language and output the graphical results to a device, and they support color PostScript images. The common code which is shared by these three programs is included as a library of routines. PSPRETTY formats a PostScript file by appropriately indenting procedures and code delimited by "saves" and "restores." PSTOOLS does not use Adobe fonts. PSTOOLS is written in C-language for implementation on SGI IRIS 4D series workstations running IRIX 3.2 or later. A README file and UNIX man pages provide information regarding the installation and use of the PSTOOLS programs. A six-page manual which provides slightly more detailed information may be purchased separately. The standard distribution medium for this package is one .25 inch streaming magnetic tape cartridge in UNIX tar format. PSIRIS (the largest program) requires 1.2Mb of main memory. PSMATRIX requires the "gpib" board (IEEE 488) available from Silicon Graphics. Inc. The programs with graphical interfaces require that the IRIS have at least 24 bit planes. This package was developed in 1990 and updated in 1991. SGI, IRIS 4D, and IRIX are trademarks of Silicon Graphics, Inc. Matrix QCRZ is a registered trademark of the AGFA Group. Tektronix 4693D is a trademark of Tektronix, Inc. Adobe is a trademark of Adobe Systems Incorporated. PostScript is a registered trademark of Adobe Systems Incorporated. UNIX is a registered trademark of AT&T Bell Laboratories.
NASA Astrophysics Data System (ADS)
Jain, P.; Recchia, M.; Cavenago, M.; Fantz, U.; Gaio, E.; Kraus, W.; Maistrello, A.; Veltri, P.
2018-04-01
Neutral beam injection (NBI) for plasma heating and current drive is necessary for International Thermonuclear Experimental reactor (ITER) tokamak. Due to its various advantages, a radio frequency (RF) driven plasma source type was selected as a reference ion source for the ITER heating NBI. The ITER relevant RF negative ion sources are inductively coupled (IC) devices whose operational working frequency has been chosen to be 1 MHz and are characterized by high RF power density (˜9.4 W cm-3) and low operational pressure (around 0.3 Pa). The RF field is produced by a coil in a cylindrical chamber leading to a plasma generation followed by its expansion inside the chamber. This paper recalls different concepts based on which a methodology is developed to evaluate the efficiency of the RF power transfer to hydrogen plasma. This efficiency is then analyzed as a function of the working frequency and in dependence of other operating source and plasma parameters. The study is applied to a high power IC RF hydrogen ion source which is similar to one simplified driver of the ELISE source (half the size of the ITER NBI source).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radojcic, Riko; Nowak, Matt; Nakamoto, Mark
The status of the development of a Design-for-Stress simulation flow that captures the stress effects in packaged 3D-stacked Si products like integrated circuits (ICs) using advanced via-middle Through Si Via technology is outlined. The next set of challenges required to proliferate the methodology and to deploy it for making and dispositioning real Si product decisions are described here. These include the adoption and support of a Process Design Kit (PDK) that includes the relevant material properties, the development of stress simulation methodologies that operate at higher levels of abstraction in a design flow, and the development and adoption of suitablemore » models required to make real product reliability decisions.« less
Cost-analysis comparison of robot-assisted laparoscopic radical cystectomy (RC) vs open RC.
Lee, Richard; Chughtai, Bilal; Herman, Michael; Shariat, Shahrokh F; Scherr, Douglas S
2011-09-01
• To systematically review and compare the economic burden of open radical cystectomy (ORC) vs robot-assisted laparoscopic radical cystectomy (RALRC) with pelvic lymph node dissection and urinary diversion. • A Medline search was conducted to identify English language articles regarding RC with urinary diversion. The resulting articles were then further restricted by the terms 'laparoscopic', 'robotic', or 'robotic-assisted'.In all, three articles were identified. • Data from each of these articles were then collected on cost performance in addition to relevant clinical variables, such as length of stay (LOS), operative duration, and complication rates. • When possible, data were subdivided by ileal conduit (IC), continent cutaneous diversion (CCD), and orthotopic neobladder (ON) subgroups. • Direct costs resulting from ORC or RALRC with accompanying hospitalization were identified. The indirect costs of complications were considered. • Despite an increased materials cost, RALRC was less expensive than ORC when the cost of complications was considered. • RALRC was less expensive than ORC for IC and CCD, but the cost advantage deteriorated for ON. • The largest cost drivers cited in the published data were LOS, operative durations, and daily hospitalizations costs. • RALRC demonstrated shorter LOS compared with ORC, although this effect was insufficient to offset the increased cost of robotic surgery. • Complications materially affected cost performance. • Despite an increased materials cost, RALRC can be more cost efficient than ORC as a treatment for bladder cancer when the impact of complications are considered. • This effect is most pronounced for patients undergoing IC. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
A cost-effective add-on-value card-assisted firewall over Taiwan's NHI VPN framework.
Huang, Jyh-Win; Hou, Ting-Wei
2007-06-01
Besides the overall budget for building the infrastructure of a healthcare-service-based virtual private network (VPN) in Taiwan, two issues were considered critical for its acceptance by the country's 17,000 plus medical institutions. One was who was to pay for the network (ADSL or modem) connection fee; the other was who was to pay for the firewall/anti-virus software. This paper addresses the second issue by proposing an efficient freeware firewall, named card-assisted firewall (CAF), for NHI VPN edge-hosts, which is also an add-on-value application of the National Healthcare IC card that every insurant and medical professional has. The innovative concept is that any NHI VPN site (edge-host) can establish diversified secure-authenticated connections with other sites only by an authentication mechanism, which requires a NHI Java card state machine and the Access Control List of the host. It is different from two-factor authentication cards in four ways: (1) a PIN code is not a must; (2) it requires authentication with the remote IC card Data Centre; (3) the NHI cards are already available, no modification is needed, and there is no further cost for the deployment of the cards; (4) although the cards are in the reader, the communication cannot start unless the cards are in the corresponding states; i.e. the states allow communication. An implementation, on a Microsoft Windows XP platform, demonstrated the system's feasibility over an emulation of the NHI VPN framework. It maintained a high line speed, the driver took up 39 KB of disk space, installation was simple, not requiring any extra hardware or software, and the average packet processing time of the CAF driver measured was 0.3084 ms. The average overhead in comparing the Access Control List predefined routing in card, in an FTP testing experiment, was 5.7 micros (receiving) and 8 micros (sending).
DIELECTROPHORESIS-BASED MICROFLUIDIC SEPARATION AND DETECTION SYSTEMS
Yang, Jun; Vykoukal, Jody; Noshari, Jamileh; Becker, Frederick; Gascoyne, Peter; Krulevitch, Peter; Fuller, Chris; Ackler, Harold; Hamilton, Julie; Boser, Bernhard; Eldredge, Adam; Hitchens, Duncan; Andrews, Craig
2009-01-01
Diagnosis and treatment of human diseases frequently requires isolation and detection of certain cell types from a complex mixture. Compared with traditional separation and detection techniques, microfluidic approaches promise to yield easy-to-use diagnostic instruments tolerant of a wide range of operating environments and capable of accomplishing automated analyses. These approaches will enable diagnostic advances to be disseminated from sophisticated clinical laboratories to the point-of-care. Applications will include the separation and differential analysis of blood cell subpopulations for host-based detection of blood cell changes caused by disease, infection, or exposure to toxins, and the separation and analysis of surface-sensitized, custom dielectric beads for chemical, biological, and biomolecular targets. Here we report a new particle separation and analysis microsystem that uses dielectrophoretic field-flow fractionation (DEP-FFF). The system consists of a microfluidic chip with integrated sample injector, a DEP-FFF separator, and an AC impedance sensor. We show the design of a miniaturized impedance sensor integrated circuit (IC) with improved sensitivity, a new packaging approach for micro-flumes that features a slide-together compression package and novel microfluidic interconnects, and the design, control, integration and packaging of a fieldable prototype. Illustrative applications will be shown, including the separation of different sized beads and different cell types, blood cell differential analysis, and impedance sensing results for beads, spores and cells. PMID:22025905
NASA Astrophysics Data System (ADS)
Jeffery, Keith; Harrison, Matt; Bailo, Daniele
2016-04-01
The EPOS-PP Project 2010-2014 proposed an architecture and demonstrated feasibility with a prototype. Requirements based on use cases were collected and an inventory of assets (e.g. datasets, software, users, computing resources, equipment/detectors, laboratory services) (RIDE) was developed. The architecture evolved through three stages of refinement with much consultation both with the EPOS community representing EPOS users and participants in geoscience and with the overall ICT community especially those working on research such as the RDA (Research Data Alliance) community. The architecture consists of a central ICS (Integrated Core Services) consisting of a portal and catalog, the latter providing to end-users a 'map' of all EPOS resources (datasets, software, users, computing, equipment/detectors etc.). ICS is extended to ICS-d (distributed ICS) for certain services (such as visualisation software services or Cloud computing resources) and CES (Computational Earth Science) for specific simulation or analytical processing. ICS also communicates with TCS (Thematic Core Services) which represent European-wide portals to national and local assets, resources and services in the various specific domains (e.g. seismology, volcanology, geodesy) of EPOS. The EPOS-IP project 2015-2019 started October 2015. Two work-packages cover the ICT aspects; WP6 involves interaction with the TCS while WP7 concentrates on ICS including interoperation with ICS-d and CES offerings: in short the ICT architecture. Based on the experience and results of EPOS-PP the ICT team held a pre-meeting in July 2015 and set out a project plan. The first major activity involved requirements (re-)collection with use cases and also updating the inventory of assets held by the various TCS in EPOS. The RIDE database of assets is currently being converted to CERIF (Common European Research Information Format - an EU Recommendation to Member States) to provide the basis for the EPOS-IP ICS Catalog. In parallel the ICT team is tracking developments in ICT for relevance to EPOS-IP. In particular, the potential utilisation of e-Is (e-Infrastructures) such as GEANT(network), AARC (security), EGI (GRID computing), EUDAT (data curation), PRACE (High Performance Computing), HELIX-Nebula / Open Science Cloud (Cloud computing) are being assessed. Similarly relationships to other e-RIs (e-Research Infrastructures) such as ENVRI+, EXCELERATE and other ESFRI (European Strategic Forum for Research Infrastructures) projects are developed to share experience and technology and to promote interoperability. EPOS ICT team members are also involved in VRE4EIC, a project developing a reference architecture and component software services for a Virtual Research Environment to be superimposed on EPOS-ICS. The challenge which is being tackled now is therefore to keep consistency and interoperability among the different modules, initiatives and actors which participate to the process of running the EPOS platform. It implies both a continuous update about IT aspects of mentioned initiatives and a refinement of the e-architecture designed so far. One major aspect of EPOS-IP is the ICT support for legalistic, financial and governance aspects of the EPOS ERIC to be initiated during EPOS-IP. This implies a sophisticated AAAI (Authentication, authorization, accounting infrastructure) with consistency throughout the software, communications and data stack.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sitaraman, S; Kim, S; Biswas, D
2010-10-27
Since the 1960's, the Department of Transportation Specification (DOT Spec) 6M packages have been used extensively for transportation of Type B quantities of radioactive materials between Department of Energy (DOE) facilities, laboratories, and productions sites. However, due to the advancement of packaging technology, the aging of the 6M packages, and variability in the quality of the packages, the DOT implemented a phased elimination of the 6M specification packages (and other DOT Spec packages) in favor of packages certified to meet federal performance requirements. DOT issued the final rule in the Federal Register on October 1, 2004 requiring that use ofmore » the DOT Specification 6M be discontinued as of October 1, 2008. A main driver for the change was the fact that the 6M specification packagings were not supported by a Safety Analysis Report for Packaging (SARP) that was compliant with Title 10 of the Code of Federal Regulations part 71 (10 CFR 71). Therefore, materials that would have historically been shipped in 6M packages are being identified as contents in Type B (and sometimes Type A fissile) package applications and addenda that are to be certified under the requirements of 10 CFR 71. The requirements in 10 CFR 71 include that the Safety Analysis Report for Packaging (SARP) must identify the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents (10 CFR 71.33(b)(1) and 10 CFR 71.33(b)(2)), and that the application (i.e., SARP submittal or SARP addendum) demonstrates that the external dose rate (due to the maximum radioactivity of radioactive constituents and maximum quantities of fissile constituents) on the surface of the packaging (i.e., package and contents) not exceed 200 mrem/hr (10 CFR 71.35(a), 10 CFR 71.47(a)). It has been proposed that a 'Small Gram Quantity' of radioactive material be defined, such that, when loaded in a transportation package, the dose rates at external points of an unshielded packaging not exceed the regulatory limits prescribed by 10 CFR 71 for non-exclusive shipments. The mass of each radioisotope presented in this paper is limited by the radiation dose rate on the external surface of the package, which per the regulatory limit should not exceed 200 mrem/hr. The results presented are a compendium of allowable masses of a variety of different isotopes (with varying impurity levels of beryllium in some of the actinide isotopes) that, when loaded in an unshielded packaging, do not result in an external dose rate on the surface of the package that exceeds 190 mrem/hr (190 mrem/hr was chosen to provide 5% conservatism relative to the regulatory limit). These mass limits define the term 'Small Gram Quantity' (SGQ) contents in the context of radioactive material transportation packages. The term SGQ is isotope-specific and pertains to contents in radioactive material transportation packages that do not require shielding and still satisfy the external dose rate requirements. Since these calculated mass limits are for contents without shielding, they are conservative for packaging materials that provide some limited shielding or if the contents are placed into a shielded package. The isotopes presented in this paper were chosen as the isotopes that Department of Energy (DOE) sites most likely need to ship. Other more rarely shipped isotopes, along with industrial and medical isotopes, are planned to be included in subsequent extensions of this work.« less
Algorithmic methods to infer the evolutionary trajectories in cancer progression
Graudenzi, Alex; Ramazzotti, Daniele; Sanz-Pamplona, Rebeca; De Sano, Luca; Mauri, Giancarlo; Moreno, Victor; Antoniotti, Marco; Mishra, Bud
2016-01-01
The genomic evolution inherent to cancer relates directly to a renewed focus on the voluminous next-generation sequencing data and machine learning for the inference of explanatory models of how the (epi)genomic events are choreographed in cancer initiation and development. However, despite the increasing availability of multiple additional -omics data, this quest has been frustrated by various theoretical and technical hurdles, mostly stemming from the dramatic heterogeneity of the disease. In this paper, we build on our recent work on the “selective advantage” relation among driver mutations in cancer progression and investigate its applicability to the modeling problem at the population level. Here, we introduce PiCnIc (Pipeline for Cancer Inference), a versatile, modular, and customizable pipeline to extract ensemble-level progression models from cross-sectional sequenced cancer genomes. The pipeline has many translational implications because it combines state-of-the-art techniques for sample stratification, driver selection, identification of fitness-equivalent exclusive alterations, and progression model inference. We demonstrate PiCnIc’s ability to reproduce much of the current knowledge on colorectal cancer progression as well as to suggest novel experimentally verifiable hypotheses. PMID:27357673
A miniature batteryless health and usage monitoring system based on hybrid energy harvesting
NASA Astrophysics Data System (ADS)
Huang, Chenling; Chakrabartty, Shantanu
2011-04-01
The cost and size of the state-of-the-art health and usage monitoring systems (HUMS) are determined by capacity of on-board energy storage which limits their large scale deployment. In this paper, we present a miniature low-cost mechanical HUMS integrated circuit (IC) based on the concept of hybrid energy harvesting where continuous monitoring is achieved by self-powering, where as the programming, localization and communication with the sensor is achieved using remote RF powering. The self-powered component of the proposed HUMS is based on our previous result which used a controllable hot electron injection on floatinggate transistor as an ultra-low power signal processor. We show that the HUMS IC can seamlessly switch between different energy harvesting modes based on the availability of ambient RF power and that the configuration, programming and communication functions can be remotely performed without physically accessing the HUMS device. All the measured results presented in this paper have been obtained from prototypes fabricated in a 0.5 micron standard CMOS process and the entire system has been successfully integrated on a 1.5cm x 1.5cm package.
Development of Equivalent Material Properties of Microbump for Simulating Chip Stacking Packaging
Lee, Chang-Chun; Tzeng, Tzai-Liang; Huang, Pei-Chen
2015-01-01
A three-dimensional integrated circuit (3D-IC) structure with a significant scale mismatch causes difficulty in analytic model construction. This paper proposes a simulation technique to introduce an equivalent material composed of microbumps and their surrounding wafer level underfill (WLUF). The mechanical properties of this equivalent material, including Young’s modulus (E), Poisson’s ratio, shear modulus, and coefficient of thermal expansion (CTE), are directly obtained by applying either a tensile load or a constant displacement, and by increasing the temperature during simulations, respectively. Analytic results indicate that at least eight microbumps at the outermost region of the chip stacking structure need to be considered as an accurate stress/strain contour in the concerned region. In addition, a factorial experimental design with analysis of variance is proposed to optimize chip stacking structure reliability with four factors: chip thickness, substrate thickness, CTE, and E-value. Analytic results show that the most significant factor is CTE of WLUF. This factor affects microbump reliability and structural warpage under a temperature cycling load and high-temperature bonding process. WLUF with low CTE and high E-value are recommended to enhance the assembly reliability of the 3D-IC architecture. PMID:28793495
Preparation and properties of sol-gel derived PZT thin films for decoupling capacitor applications
NASA Astrophysics Data System (ADS)
Schwartz, R. W.; Dimos, D.; Lockwood, S. J.; Torres, V. M.
The use of ceramic thin films as decoupling capacitors offers the possibility of capacitor integration within the integrated circuit (IC) package and, potentially, directly onto the IC itself. Since these configurations minimize series inductance, higher operational speeds are possible. In the present study, the authors have investigated the dielectric and leakage characteristics of sol-gel PZT films. For compositions near the morphotropic phase boundary, dielectric constants of 1000, and loss tangents of about 0.02, are observed. The current-voltage behavior of the capacitors is characterized by a non-linear response, and significant asymmetry in both the leakage and breakdown characteristics as a function of bias sign is observed. Breakdown fields for PZT 53/47 thin films are typically approximately 800 kV/cm at 25 C. The authors have also studied the effects of La and Nb dopant additions and alternate firing strategies on film leakage characteristics. Donor doping at 2 - 5 mol % lowers leakage currents by a factor of 10(exp 3). For films prepared by a multilayering approach, firing each layer to crystallization results in leakage currents that are a factor of 10(exp 2) lower than films prepared by the standard process.
4 channels x 10-Gbps optoelectronic transceiver based on silicon optical bench technology
NASA Astrophysics Data System (ADS)
Chen, Chin T.; Hsiao, Hsu L.; Chang, Chia. C.; Shen, Po K.; Lu, Guan F.; Lee, Yun C.; Chang, Shou F.; Lin, Yo S.; Wu, Mount L.
2012-01-01
In this paper, a bi-directional 4-channel x 10-Gbps optoelectronic transceiver based on this silicon optical bench (SiOB) technology is developed. A bi-directional optical sub-assembly (BOSA), fiber ribbon assembly, PCB with high frequency trace design, transmitter driver, and receiver TIA IC are included in this transceiver. The BOSA and PCB also have some specific design for conventional chip-on-board (COB) process. In eye diagram measurement, the transmitter can pass 10-G Ethernet eye mask with 25% margin at room temperature; Bit-error-rate (BER) performance from the transmitter to receiver via 10-meter fiber can achieve 10-12 order, which confirm the transceiver's ability of 10-Gbps data transmission per a channel.
GEMPAK 5.1 - A GENERAL METEOROLOGICAL PACKAGE (VAX VMS VERSION)
NASA Technical Reports Server (NTRS)
Des, Jardins M. L.
1994-01-01
GEMPAK is a general meteorological software package developed at NASA/Goddard Space Flight Center. It includes programs to analyze and display surface, upper-air, and gridded data, including model output. There are very general programs to list, edit, and plot data on maps, to display profiles and time series, to draw and fill contours, to draw streamlines, to plot symbols for clouds, sky cover, and pressure tendency, and draw cross sections in the case of gridded data and sounding data. In addition, there are Barnes objective analysis programs to grid surface and upper-air data. The programs include the capabilities to derive meteorological parameters from those found in the dataset, to perform vertical interpolations of sounding data to different coordinate systems, and to compute an extensive set of gridded diagnostic quantities by specifying various nested combinations of scalars and vector arithmetic, algebraic, and differential operators. The GEMPAK 5.1 graphics/transformation subsystem, GEMPLT, provides device-independent graphics. GEMPLT also has the capability to display output in a variety of map projections or overlaid on satellite imagery. GEMPAK 5.1 is written in FORTRAN 77 and C-language and has been implemented on VAX computers under VMS and on computers running the UNIX operating system. During installation and normal use, this package occupies approximately 100Mb of hard disk space. The UNIX version of GEMPAK includes drivers for several graphic output systems including MIT's X Window System (X11,R4), Sun GKS, PostScript (color and monochrome), Silicon Graphics, and others. The VMS version of GEMPAK also includes drivers for several graphic output systems including PostScript (color and monochrome). The VMS version is delivered with the object code for the Transportable Applications Environment (TAE) program, version 4.1 which serves as a user interface. A color monitor is recommended for displaying maps on video display devices. Data for rendering regional maps is included with this package. The standard distribution medium for the UNIX version of GEMPAK 5.1 is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The standard distribution medium for the VMS version of GEMPAK 5.1 is a 6250 BPI 9-track magnetic tape in DEC VAX BACKUP format. The VMS version is also available on a TK50 tape cartridge in DEC VAX BACKUP format. This program was developed in 1985. The current version, GEMPAK 5.1, was released in 1992. The package is delivered with source code. An extensive collection of subroutine libraries allows users to format data for use by GEMPAK, to develop new programs, and to enhance existing ones.
NASA Astrophysics Data System (ADS)
Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.
2010-07-01
The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.
Three-axis accelerometer package for slimhole and microhole seismic monitoring and surveys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, S.L.; Harben, P.E.
1997-01-07
The development of microdrilling technology, nominally defined as drilling technology for 1-in.-diameter boreholes, shows potential for reducing the cost of drilling monitoring wells. A major question that arises in drilling microholes is if downhole logging and monitoring in general--and downhole seismic surveying in particular--can be conducted in such small holes since the inner working diameter of such a seismic tool could be as small as 0.31 in. A downhole three-component accelerometer package that fits within a 031-in. inner diameter tube has been designed, built, and tested. The package consists of three orthogonally mounted Entran EGA-125-5g piezoresistive silicon micromachined accelerometers withmore » temperature compensation circuitry, downhole amplification, and line drivers mounted in a thin-walled aluminum tube. Accelerometers are commercially available in much smaller package sizes than conventional geophones, but the noise floor is significantly higher than that for the geophones. Cross-well tests using small explosives showed good signal-to-noise ratio in the recorded waveform at various receiver depths with a 1,50-ft source-receiver well separation. For some active downhole surveys, the accelerometer unit would clearly be adequate. It can be reasonably assumed, however, that for less energetic sources and for greater well separations, the high accelerometer noise floor is not acceptable. By expanding the inner working diameter of a microhole seismic tool to 0.5 in., other commercial accelerometers can be used with substantially lower noise floors.« less
Influence of packaging information on consumer liking of chocolate milk.
Kim, M K; Lopetcharat, K; Drake, M A
2013-08-01
Chocolate milk varies widely in flavor, color, and viscosity, and liking is influenced by these properties. Additionally, package labels (declared fat content) and brand are some of the extrinsic factors that may influence consumer perception. The objective of this study was to evaluate the effects of packaging labels and brand name on consumer liking and purchase intent of chocolate milk. A consumer acceptance test, conjoint analysis survey, and Kano analysis were conducted. One hundred eight consumers evaluated 7 chocolate milks with and without brand or package information in a 2-d crossover design. A conjoint analysis survey and Kano analysis were conducted after the consumer acceptance test. Results were evaluated by 2-way ANOVA and multivariate analyses. Declared fat content and brand influenced overall liking and purchase intent for chocolate milks to differing degrees. A subsequent conjoint analysis (n=250) revealed that fat content was a driver of choice for purchasing chocolate milk followed by sugar content and brand. Brand name was less important for purchase intent of chocolate milk than fat or sugar content. Among fat content of chocolate milk, 2 and 1% fat level were most appealing to consumers, and reduced sugar and regular sugar were equally important for purchase intent. Kano analysis confirmed that fat content (whole milk, 1, or 2% fat chocolate milk) was an attractive attribute for consumer satisfaction, more so than brand. Organic labeling did not affect the purchase decision of chocolate milk; however, Kano results revealed that having an organic label on a package positively influenced consumer satisfaction. Findings from this study can help chocolate milk producers as well as food marketers better target their product labels with attributes that drive consumer choice of chocolate milk. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Chemical effect on diffusion in intermetallic compounds
NASA Astrophysics Data System (ADS)
Chen, Yi-Ting
With the trend of big data and the Internet of things, we live in a world full of personal electronic devices and small electronic devices. In order to make the devices more powerful, advanced electronic packaging such as wafer level packaging or 3D IC packaging play an important role. Furthermore, ?-bumps, which connect silicon dies together with dimension less than 10 ?m, are crucial parts in advanced packaging. Owing to the dimension of ?-bumps, they transform into intermetallic compound from tin based solder after the liquid state bonding process. Moreover, many new reliability issues will occur in electronic packaging when the bonding materials change; in this case, we no longer have tin based solder joint, instead, we have intermetallic compound ?-bumps. Most of the potential reliability issues in intermetallic compounds are caused by the chemical reactions driven by atomic diffusion in the material; thus, to know the diffusivities of atoms inside a material is significant and can help us to further analyze the reliability issues. However, we are lacking these kinds of data in intermetallic compound because there are some problems if used traditional Darken's analysis. Therefore, we considered Wagner diffusivity in our system to solve the problems and applied the concept of chemical effect on diffusion by taking the advantage that large amount of energy will release when compounds formed. Moreover, by inventing the holes markers made by Focus ion beam (FIB), we can conduct the diffusion experiment and obtain the tracer diffusivities of atoms inside the intermetallic compound. We applied the technique on Ni3Sn4 and Cu3Sn, which are two of the most common materials in electronic packaging, and the tracer diffusivities are measured under several different temperatures; moreover, microstructure of the intermetallic compounds are investigated to ensure the diffusion environment. Additionally, the detail diffusion mechanism was also discussed in aspect of diffusion activation enthalpy and diffusion pre-factor by using lattice structure simulation. Last but not the least, X-ray photoelectron spectroscopy and First principal calculation simulation were used to observe the electron binding energies in the intermetallic compound and illustrate the partial covalent bonding behavior in the intermetallic compounds.
NASA Astrophysics Data System (ADS)
Haghgoo, Esmail; Zamani, Mohammad; Sharbati, Ali
2017-02-01
The point of this article is introducing the usage of electronic power steering (ESP) system in IKCO SAMAND vehicle and investigating on it's benefit's. Also the operation of electronic steering system and it's performance in IKCO SAMAND vehicle have been described. The optimization of IC engine efficiency and it's fuel consumption have been simulated via ADVISOR software used in MATLAB software. Usually, mechanical steering systems and hydraulic steering systems are producing inside IRAN that the mechanical types have not accepted because of it's too many disadvantages. The hydraulic steering systems, that have been replaced with mechanical types, indeed have the same features with mechanical types but with a difference which they have a hydraulic booster to facilitate the rotation of steering wheel. Beside advantages in hydraulic systems, they are some disadvantages in this system that one of the most important of them is reducing the output power of engine. To restore this power dissipated, we use ESP systems. In this article output diagrams given by software, are showing that IKCO SAMAND vehicle which equipped with ESP system, exerts less torque and power on steering wheel. This improves the safety of driver and also performance of the vehicle at high speeds and reduces fuel consumption beside increasing the efficiency of IC engine.
Interfacing the Controllogics PLC over Ethernet/IP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasemir, K. U.; Dalesio, L. R.
2001-01-01
The Allen-Bradley ControlLogix [1] line of programmable logic controllers (PLCs) offers several interfaces: Ethernet, ControlNet, DeviceNet, RS-232 and others. The ControlLogix Ethernet interface module 1756-ENET uses EtherNet/IP, the ControlNet protocol [2], encapsulated in Ethernet packages, with specific service codes [3]. A driver for the Experimental Physics and Industrial Control System (EPICS) has been developed that utilizes this EtherNet/IP protocol for controllers running the vxWorks RTOS as well as a Win32 and Unix/Linux test program. Features, performance and limitations of this interface are presented.
High-frequency ultrasonic wire bonding systems
Tsujino; Yoshihara; Sano; Ihara
2000-03-01
The vibration characteristics of longitudinal-complex transverse vibration systems with multiple resonance frequencies of 350-980 kHz for ultrasonic wire bonding of IC, LSI or electronic devices were studied. The complex vibration systems can be applied for direct welding of semiconductor tips (face-down bonding, flip-chip bonding) and packaging of electronic devices. A longitudinal-complex transverse vibration bonding system consists of a complex transverse vibration rod, two driving longitudinal transducers 7.0 mm in diameter and a transverse vibration welding tip. The vibration distributions along ceramic and stainless-steel welding tips were measured at up to 980 kHz. A high-frequency vibration system with a height of 20.7 mm and a weight of less than 15 g was obtained.
Reliable aluminum contact formation by electrostatic bonding
NASA Astrophysics Data System (ADS)
Kárpáti, T.; Pap, A. E.; Radnóczi, Gy; Beke, B.; Bársony, I.; Fürjes, P.
2015-07-01
The paper presents a detailed study of a reliable method developed for aluminum fusion wafer bonding assisted by the electrostatic force evolving during the anodic bonding process. The IC-compatible procedure described allows the parallel formation of electrical and mechanical contacts, facilitating a reliable packaging of electromechanical systems with backside electrical contacts. This fusion bonding method supports the fabrication of complex microelectromechanical systems (MEMS) and micro-opto-electromechanical systems (MOEMS) structures with enhanced temperature stability, which is crucial in mechanical sensor applications such as pressure or force sensors. Due to the applied electrical potential of -1000 V the Al metal layers are compressed by electrostatic force, and at the bonding temperature of 450 °C intermetallic diffusion causes aluminum ions to migrate between metal layers.
An Evaluation of the Healthiness of the Indian Packaged Food and Beverage Supply.
Jones, Alexandra; Dunford, Elizabeth; Crossley, Rachel; Thout, Sudhir Raj; Rayner, Mike; Neal, Bruce
2017-10-09
Availability of less-healthy packaged food and beverage products has been implicated as an important driver of obesity and diet-related disease. An increasing number of packaged foods and beverages are sold in India. Our objective was to evaluate the healthiness of packaged foods sold by India's largest manufacturers. Healthiness was assessed using the Australian Health Star Rating (HSR) system and the World Health Organization's European Regional Office (WHO Euro) Nutrient Profile Model. Sales-value-weighted mean healthiness and the proportions of "healthy" products (using a validated HSR cut-off of ≥3.5, and products meeting WHO Euro criteria as healthy enough to market to children) were calculated overall, by company and by food category. Nutrient information for 943 products sold by the 11 largest Indian manufacturers was obtained from nutrient labels, company websites or directly from the manufacturer. Healthiness was low overall (mean HSR 1.8 out of 5.0 stars) with a low proportion defined as "healthy" by both HSR (17%) and also by WHO Euro criteria (8%). There were marked differences in the healthiness of similar products within food categories. Substantial variation between companies (minimum sales-value-weighted mean HSR 0.5 for Company G, versus maximum HSR 3.0 for Company F) was a result of differences in the types of products sold and the nutritional composition of individual products. There are clear opportunities for India's largest food companies to improve both the nutritional quality of individual products and to improve their product mix to include a greater proportion of healthy products.
An Evaluation of the Healthiness of the Indian Packaged Food and Beverage Supply
Jones, Alexandra; Crossley, Rachel; Thout, Sudhir Raj; Rayner, Mike; Neal, Bruce
2017-01-01
Availability of less-healthy packaged food and beverage products has been implicated as an important driver of obesity and diet-related disease. An increasing number of packaged foods and beverages are sold in India. Our objective was to evaluate the healthiness of packaged foods sold by India’s largest manufacturers. Healthiness was assessed using the Australian Health Star Rating (HSR) system and the World Health Organization’s European Regional Office (WHO Euro) Nutrient Profile Model. Sales-value-weighted mean healthiness and the proportions of “healthy” products (using a validated HSR cut-off of ≥3.5, and products meeting WHO Euro criteria as healthy enough to market to children) were calculated overall, by company and by food category. Nutrient information for 943 products sold by the 11 largest Indian manufacturers was obtained from nutrient labels, company websites or directly from the manufacturer. Healthiness was low overall (mean HSR 1.8 out of 5.0 stars) with a low proportion defined as “healthy” by both HSR (17%) and also by WHO Euro criteria (8%). There were marked differences in the healthiness of similar products within food categories. Substantial variation between companies (minimum sales-value-weighted mean HSR 0.5 for Company G, versus maximum HSR 3.0 for Company F) was a result of differences in the types of products sold and the nutritional composition of individual products. There are clear opportunities for India’s largest food companies to improve both the nutritional quality of individual products and to improve their product mix to include a greater proportion of healthy products. PMID:28991201
X-Band, 17-Watt Solid-State Power Amplifier
NASA Technical Reports Server (NTRS)
Mittskus, Anthony; Stone, Ernest; Boger, William; Burgess, David; Honda, Richard; Nuckolls, Carl
2005-01-01
An advanced solid-state power amplifier that can generate an output power of as much as 17 W at a design operating frequency of 8.4 GHz has been designed and constructed as a smaller, lighter, less expensive alternative to traveling-wave-tube X-band amplifiers and to prior solid-state X-band power amplifiers of equivalent output power. This amplifier comprises a monolithic microwave integrated circuit (MMIC) amplifier module and a power-converter module integrated into a compact package (see Figure 1). The amplifier module contains an input variable-gain amplifier (VGA), an intermediate driver stage, a final power stage, and input and output power monitors (see Figure 2). The VGA and the driver amplifier are 0.5-m GaAs-based metal semiconductor field-effect transistors (MESFETs). The final power stage contains four parallel high-efficiency, GaAs-based pseudomorphic high-electron-mobility transistors (PHEMTs). The gain of the VGA is voltage-variable over a range of 10 to 24 dB. To provide for temperature compensation of the overall amplifier gain, the gain-control voltage is generated by an operational-amplifier circuit that includes a resistor/thermistor temperature-sensing network. The driver amplifier provides a gain of 14 dB to an output power of 27 dBm to drive the four parallel output PHEMTs, each of which is nominally capable of putting out as much as 5 W. The driver output is sent to the input terminals of the four parallel PHEMTs through microstrip power dividers; the outputs of these PHEMTs are combined by microstrip power combiners (which are similar to the microstrip power dividers) to obtain the final output power of 17 W.
Integrated HIFU Drive System on a Chip for CMUT-Based Catheter Ablation System.
Farhanieh, Omid; Sahafi, Ali; Bardhan Roy, Rupak; Ergun, Arif Sanli; Bozkurt, Ayhan
2017-06-01
Conventional High Intensity Focused Ultrasound (HIFU) is a therapeutic modality which is extracorporeally administered. In applications where a relatively small HIFU lesion is required, an intravascular HIFU probe can be deployed to the ablation site. In this paper, we demonstrate the design and implementation a fully integrated HIFU drive system on a chip to be placed on a 6 Fr catheter probe. An 8-element capacitive micromachined ultrasound transducer (CMUT) ring array of 2 mm diameter has been used as the ultrasound source. The driver chip is fabricated in 0.35 μm AMS high-voltage CMOS technology and comprises eight continuous-wave (CW) high-voltage CMUT drivers (10.9 ns and 9.4 ns rise and fall times at 20 V pp output into a 15 pF), an eight-channel digital beamformer (8-12 MHz output frequency with 11.25 ° phase accuracy) and a phase locked loop with an integrated VCO as a tunable clock source (128-192 MHz). The chip occupies 1.85 × 1.8 mm 2 area including input and output (I/O) pads. When the transducer array is immersed in sunflower oil and driven by the IC with eight 20 V pp CW pulses at 10 MHz, real-time thermal images of the HIFU beam indicate that the focal temperature rises by 16.8 ° C in 11 seconds. Each HV driver consumes around 67 mW of power when driving the CMUT array at 10 MHz, which adds up to 560 mW for the whole chip. FEM based analysis reveals that the outer surface temperature of the catheter is expected to remain below the 42 ° C tissue damage limit during therapy.
Stacked Transformer for Driver Gain and Receive Signal Splitting
NASA Technical Reports Server (NTRS)
Driscoll, Kevin R.
2013-01-01
In a high-speed signal transmission system that uses transformer coupling, there is a need to provide increased transmitted signal strength without adding active components. This invention uses additional transformers to achieve the needed gain. The prior art uses stronger drivers (which require an IC redesign and a higher power supply voltage), or the addition of another active component (which can decrease reliability, increase power consumption, reduce the beneficial effect of serializer/deserializer preemphasis or deemphasis, and/or interfere with fault containment mechanisms), or uses a different transformer winding ratio (which requires redesign of the transformer and may not be feasible with high-speed signals that require a 1:1 winding ratio). This invention achieves the required gain by connecting the secondaries of multiple transformers in series. The primaries of these transformers are currently either connected in parallel or are connected to multiple drivers. There is also a need to split a receive signal to multiple destinations with minimal signal loss. Additional transformers can achieve the split. The prior art uses impedance-matching series resistors that cause a loss of signal. Instead of causing a loss, most instantiations of this invention would actually provide gain. Multiple transformers are used instead of multiple windings on a single transformer because multiple windings on the same transformer would require a redesign of the transformer, and may not be feasible with high-speed transformers that usually require a bifilar winding with a 1:1 ratio. This invention creates the split by connecting the primaries of multiple transformers in series. The secondary of each transformer is connected to one of the intended destinations without the use of impedance-matching series resistors.
NASA Astrophysics Data System (ADS)
Mang, Ou-Yang; Ko, Mei Lan; Tsai, Yi-Chun; Chiou, Jin-Chern; Huang, Ting-Wei
2016-03-01
The pupil response to light can reflect various kinds of diseases which are related to physiological health. Pupillary abnormalities may be influenced on people by autonomic neuropathy, glaucoma, diabetes, genetic diseases, and high myopia. In the early stage of neuropathy, it is often asymptomatic and difficulty detectable by ophthalmologists. In addition, the position of injured nerve can lead to unsynchronized pupil response for human eyes. In our study, we design the pupilometer to measure the binocular pupil response simultaneously. It uses the different wavelength of LEDs such as white, red, green and blue light to stimulate the pupil and record the process. Therefore, the pupilometer mainly contains two systems. One is the image acquisition system, it use the two cameras modules with the same external triggered signal to capture the images of the pupil simultaneously. The other one is the illumination system. It use the boost converter ICs and LED driver ICs to supply the constant current for LED to maintain the consistent luminance in each experiments for reduced experimental error. Furthermore, the four infrared LEDs are arranged nearby the stimulating LEDs to illuminate eyes and increase contrast of image for image processing. In our design, we success to implement the function of synchronized image acquisition with the sample speed in 30 fps and the stable illumination system for precise measurement of experiment.
Carpenter, Thomas M.; Rashid, M. Wasequr; Ghovanloo, Maysam; Cowell, David M. J.; Freear, Steven; Degertekin, F. Levent
2016-01-01
In real-time catheter based 3D ultrasound imaging applications, gathering data from the transducer arrays is difficult as there is a restriction on cable count due to the diameter of the catheter. Although area and power hungry multiplexing circuits integrated at the catheter tip are used in some applications, these are unsuitable for use in small sized catheters for applications like intracardiac imaging. Furthermore, the length requirement for catheters and limited power available to on-chip cable drivers leads to limited signal strength at the receiver end. In this paper an alternative approach using Analog Time Division Multiplexing (TDM) is presented which addresses the cable restrictions of ultrasound catheters. A novel digital demultiplexing technique is also described which allows for a reduction in the number of analog signal processing stages required. The TDM and digital demultiplexing schemes are demonstrated for an intracardiac imaging system that would operate in the 4 MHz to 11 MHz range. A TDM integrated circuit (IC) with 8:1 multiplexer is interfaced with a fast ADC through a micro-coaxial catheter cable bundle, and processed with an FPGA RTL simulation. Input signals to the TDM IC are recovered with −40 dB crosstalk between channels on the same micro-coax, showing the feasibility of this system for ultrasound imaging applications. PMID:27116738
Kim, SangYun; Samadpoor Rikan, Behnam; Pu, YoungGun; Yoo, Sang-Sun; Lee, Minjae; Yang, Youngoo; Lee, Kang-Yoon
2018-01-01
In this paper, a high noise immunity, 28 × 16-channel finger touch sensing IC for an orthogonal frequency division multiplexing (OFDM) touch sensing scheme is presented. In order to increase the signal-to-noise ratio (SNR), the OFDM sensing scheme is proposed. The transmitter (TX) transmits the orthogonal signal to each channels of the panel. The receiver (RX) detects the magnitude of the orthogonal frequency to be transmitted from the TX. Due to the orthogonal characteristics, it is robust to narrowband interference and noise. Therefore, the SNR can be improved. In order to reduce the noise effect of low frequencies, a mixer and high-pass filter are proposed as well. After the noise is filtered, the touch SNR attained is 60 dB, from 20 dB before the noise is filtered. The advantage of the proposed OFDM sensing scheme is its ability to detect channels of the panel simultaneously with the use of multiple carriers. To satisfy the linearity of the signal in the OFDM system, a high-linearity mixer and a rail-to-rail amplifier in the TX driver are designed. The proposed design is implemented in 90 nm CMOS process. The SNR is approximately 60 dB. The area is 13.6 mm2, and the power consumption is 62.4 mW. PMID:29883435
The Effect of DEM Source and Grid Size on the Index of Connectivity in Savanna Catchments
NASA Astrophysics Data System (ADS)
Jarihani, Ben; Sidle, Roy; Bartley, Rebecca; Roth, Christian
2017-04-01
The term "hydrological connectivity" is increasingly used instead of sediment delivery ratio to describe the linkage between the sources of water and sediment within a catchment to the catchment outlet. Sediment delivery ratio is an empirical parameter that is highly site-specific and tends to lump all processes, whilst hydrological connectivity focuses on the spatially-explicit hydrologic drivers of surficial processes. Detailed topographic information plays a fundamental role in geomorphological interpretations as well as quantitative modelling of sediment fluxes and connectivity. Geomorphometric analysis permits a detailed characterization of drainage area and drainage pattern together with the possibility of characterizing surface roughness. High resolution topographic data (i.e., LiDAR) are not available for all areas; however, remotely sensed topographic data from multiple sources with different grid sizes are used to undertake geomorphologic analysis in data-sparse regions. The Index of Connectivity (IC), a geomorphometric model based only on DEM data, is applied in two small savanna catchments in Queensland, Australia. The influence of the scale of the topographic data is explored by using DEMs from LiDAR ( 1 m), WorldDEM ( 10 m), raw SRTM and hydrologically corrected SRTM derived data ( 30 m) to calculate the index of connectivity. The effect of the grid size is also investigated by resampling the high resolution LiDAR DEM to multiple grid sizes (e.g. 5, 10, 20 m) and comparing the extracted IC.
Reduce volume of head-up display by image stitching
NASA Astrophysics Data System (ADS)
Chiu, Yi-Feng; Su, Guo-Dung J.
2016-09-01
Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.
Wang, Zhiqiang; Shi, Xiaojie; Tolbert, Leon M.; ...
2014-04-30
Here we present a board-level integrated silicon carbide (SiC) MOSFET power module for high temperature and high power density application. Specifically, a silicon-on-insulator (SOI)-based gate driver capable of operating at 200°C ambient temperature is designed and fabricated. The sourcing and sinking current capability of the gate driver are tested under various ambient temperatures. Also, a 1200 V/100 A SiC MOSFET phase-leg power module is developed utilizing high temperature packaging technologies. The static characteristics, switching performance, and short-circuit behavior of the fabricated power module are fully evaluated at different temperatures. Moreover, a buck converter prototype composed of the SOI gate drivermore » and SiC power module is built for high temperature continuous operation. The converter is operated at different switching frequencies up to 100 kHz, with its junction temperature monitored by a thermosensitive electrical parameter and compared with thermal simulation results. The experimental results from the continuous operation demonstrate the high temperature capability of the power module at a junction temperature greater than 225°C.« less
Technology-design-manufacturing co-optimization for advanced mobile SoCs
NASA Astrophysics Data System (ADS)
Yang, Da; Gan, Chock; Chidambaram, P. R.; Nallapadi, Giri; Zhu, John; Song, S. C.; Xu, Jeff; Yeap, Geoffrey
2014-03-01
How to maintain the Moore's Law scaling beyond the 193 immersion resolution limit is the key question semiconductor industry needs to answer in the near future. Process complexity will undoubtfully increase for 14nm node and beyond, which brings both challenges and opportunities for technology development. A vertically integrated design-technologymanufacturing co-optimization flow is desired to better address the complicated issues new process changes bring. In recent years smart mobile wireless devices have been the fastest growing consumer electronics market. Advanced mobile devices such as smartphones are complex systems with the overriding objective of providing the best userexperience value by harnessing all the technology innovations. Most critical system drivers are better system performance/power efficiency, cost effectiveness, and smaller form factors, which, in turns, drive the need of system design and solution with More-than-Moore innovations. Mobile system-on-chips (SoCs) has become the leading driver for semiconductor technology definition and manufacturing. Here we highlight how the co-optimization strategy influenced architecture, device/circuit, process technology and package, in the face of growing process cost/complexity and variability as well as design rule restrictions.
Personalised food: how personal is it?
Ghosh, Dilip
2010-03-01
Consumer goods became increasingly personalised, particularly during the last half of the 20th century. Foods and food products have been added a new flavour in this consumer trends with increasingly personalised values of convenience, cost, packaging, and taste. Now functional food industry is ready to take its next venture in a relatively new domain personalising health. Whether the goal of matching foods to individual genotypes to improve the health of those individuals can be attained, and personalised nutrigenomic foods enter the world's food markets, depends on numerous hurdles being overcome: some scientific in nature, some technical and others related to consumer, market or ethical issues. Public adoption of new technologies is an important determinant for their success. Many of the drivers behind the trend in personalisation of food are now known, particularly ethical, legal and social issues (ELSI) are the major drivers. Future development in the field of nutrigenomics undoubtedly will place its seemingly huge potential in better perspective. Thus, the agriculture and food enterprise has an extraordinary opportunity to link individuals with foods that are personalised for their health.
RCHILD - an R-package for flexible use of the landscape evolution model CHILD
NASA Astrophysics Data System (ADS)
Dietze, Michael
2014-05-01
Landscape evolution models provide powerful approaches to numerically assess earth surface processes, to quantify rates of landscape change, infer sediment transfer rates, estimate sediment budgets, investigate the consequences of changes in external drivers on a geomorphic system, to provide spatio-temporal interpolations between known landscape states or to test conceptual hypotheses. CHILD (Channel-Hillslope Integrated Landscape Development Model) is one of the most-used models of landscape change in the context of at least tectonic and geomorphologic process interactions. Running CHILD from command line and working with the model output can be a rather awkward task (static model control via text input file, only numeric output in text files). The package RCHILD is a collection of functions for the free statistical software R that help using CHILD in a flexible, dynamic and user-friendly way. The comprised functions allow creating maps, real-time scenes, animations and further thematic plots from model output. The model input files can be modified dynamically and, hence, (feedback-related) changes in external factors can be implemented iteratively. Output files can be written to common formats that can be readily imported to standard GIS software. This contribution presents the basic functionality of the model CHILD as visualised and modified by the package. A rough overview of the available functions is given. Application examples help to illustrate the great potential of numeric modelling of geomorphologic processes.
LED lighting efficacy: Status and directions
Morgan Pattison, Paul; Hansen, Monica; Tsao, Jeffrey Y.
2017-12-28
A monumental shift from conventional lighting technologies (incandescent, fluorescent, high intensity discharge) to LED lighting is currently transpiring. The primary driver for this shift has been energy and associated cost savings. LED lighting is now more efficacious than any of the conventional lighting technologies with room to still improve. Near term, phosphor converted LED packages have the potential for efficacy improvement from 160 lm/W to 255 lm/W. Longer term, color-mixed LED packages have the potential for efficacy levels conceivably as high as 330 lm/W, though reaching these performance levels requires breakthroughs in green and amber LED efficiency. LED package efficacymore » sets the upper limit to luminaire efficacy, with the luminaire containing its own efficacy loss channels. In this paper, based on analyses performed through the U.S. Department of Energy Solid State Lighting Program, various LED and luminaire loss channels are elucidated, and critical areas for improvement identified. Beyond massive energy savings, LED technology enables a host of new applications and added value not possible or economical with previous lighting technologies. These include connected lighting, lighting tailored for human physiological responses, horticultural lighting, and ecologically conscious lighting. Finally, none of these new applications would be viable if not for the high efficacies that have been achieved, and are themselves just the beginning of what LED lighting can do.« less
LED lighting efficacy: Status and directions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan Pattison, Paul; Hansen, Monica; Tsao, Jeffrey Y.
A monumental shift from conventional lighting technologies (incandescent, fluorescent, high intensity discharge) to LED lighting is currently transpiring. The primary driver for this shift has been energy and associated cost savings. LED lighting is now more efficacious than any of the conventional lighting technologies with room to still improve. Near term, phosphor converted LED packages have the potential for efficacy improvement from 160 lm/W to 255 lm/W. Longer term, color-mixed LED packages have the potential for efficacy levels conceivably as high as 330 lm/W, though reaching these performance levels requires breakthroughs in green and amber LED efficiency. LED package efficacymore » sets the upper limit to luminaire efficacy, with the luminaire containing its own efficacy loss channels. In this paper, based on analyses performed through the U.S. Department of Energy Solid State Lighting Program, various LED and luminaire loss channels are elucidated, and critical areas for improvement identified. Beyond massive energy savings, LED technology enables a host of new applications and added value not possible or economical with previous lighting technologies. These include connected lighting, lighting tailored for human physiological responses, horticultural lighting, and ecologically conscious lighting. Finally, none of these new applications would be viable if not for the high efficacies that have been achieved, and are themselves just the beginning of what LED lighting can do.« less
HEMT Amplifiers and Equipment for their On-Wafer Testing
NASA Technical Reports Server (NTRS)
Fung, King man; Gaier, Todd; Samoska, Lorene; Deal, William; Radisic, Vesna; Mei, Xiaobing; Lai, Richard
2008-01-01
Power amplifiers comprising InP-based high-electron-mobility transistors (HEMTs) in coplanar-waveguide (CPW) circuits designed for operation at frequencies of hundreds of gigahertz, and a test set for onwafer measurement of their power levels have been developed. These amplifiers utilize an advanced 35-nm HEMT monolithic microwave integrated-circuit (MMIC) technology and have potential utility as local-oscillator drivers and power sources in future submillimeter-wavelength heterodyne receivers and imaging systems. The test set can reduce development time by enabling rapid output power characterization, not only of these and similar amplifiers, but also of other coplanar-waveguide power circuits, without the necessity of packaging the circuits.
Low-cost optical interconnect module for parallel optical data links
NASA Astrophysics Data System (ADS)
Noddings, Chad; Hirsch, Tom J.; Olla, M.; Spooner, C.; Yu, Jason J.
1995-04-01
We have designed, fabricated, and tested a prototype parallel ten-channel unidirectional optical data link. When scaled to production, we project that this technology will satisfy the following market penetration requirements: (1) up to 70 meters transmission distance, (2) at least 1 gigabyte/second data rate, and (3) 0.35 to 0.50 MByte/second volume selling price. These goals can be achieved by means of the assembly innovations described in this paper: a novel alignment method that is integrated with low-cost, few chip module packaging techniques, yielding high coupling and reducing the component count. Furthermore, high coupling efficiency increases projected reliability reducing the driver's power requirements.
Rooftop package unit diagnostician
Chassin, David P [Pasco, WA; Pratt, Robert G [Kennewick, WA; Reid, Larry Dean [Benton City, WA
2004-08-17
A diagnostic system for an HVAC system includes a number of sensors used to measure the operation of the HVAC system. Sensor readings are measured by timing the delay between when a strobe signal is sent to a sensor and when an interrupt signal from the sensor is received. A device driver used to measure the sensor readings stores the sensor readings in pseudo-character device files, which are universally accessible by different subsystems of the diagnostic system. Based on the readings from these sensors, this diagnostic system is able to determine the operational status of the HVAC system and if an economizer in the HVAC system is operating properly.
Guleyupoglu, B; Schap, J; Kusano, K D; Gayzik, F S
2017-07-04
The objective of this study is to use a validated finite element model of the human body and a certified model of an anthropomorphic test dummy (ATD) to evaluate the effect of simulated precrash braking on driver kinematics, restraint loads, body loads, and computed injury criteria in 4 commonly injured body regions. The Global Human Body Models Consortium (GHBMC) 50th percentile male occupant (M50-O) and the Humanetics Hybrid III 50th percentile models were gravity settled in the driver position of a generic interior equipped with an advanced 3-point belt and driver airbag. Fifteen simulations per model (30 total) were conducted, including 4 scenarios at 3 severity levels: median, severe, and the U.S. New Car Assessment Program (U.S.-NCAP) and 3 extra per model with high-intensity braking. The 4 scenarios were no precollision system (no PCS), forward collision warning (FCW), FCW with prebraking assist (FCW+PBA), and FCW and PBA with autonomous precrash braking (FCW + PBA + PB). The baseline ΔV was 17, 34, and 56.4 kph for median, severe, and U.S.-NCAP scenarios, respectively, and were based on crash reconstructions from NASS/CDS. Pulses were then developed based on the assumed precrash systems equipped. Restraint properties and the generic pulse used were based on literature. In median crash severity cases, little to no risk (<10% risk for Abbreviated injury Scale [AIS] 3+) was found for all injury measures for both models. In the severe set of cases, little to no risk for AIS 3+ injury was also found for all injury measures. In NCAP cases, highest risk was typically found with No PCS and lowest with FCW + PBA + PB. In the higher intensity braking cases (1.0-1.4 g), head injury criterion (HIC), brain injury criterion (BrIC), and chest deflection injury measures increased with increased braking intensity. All other measures for these cases tended to decrease. The ATD also predicted and trended similar to the human body models predictions for both the median, severe, and NCAP cases. Forward excursion for both models decreased across median, severe, and NCAP cases and diverged from each other in cases above 1.0 g of braking intensity. The addition of precrash systems simulated through reduced precrash speeds caused reductions in some injury criteria, whereas others (chest deflection, HIC, and BrIC) increased due to a modified occupant position. The human model and ATD models trended similarly in nearly all cases with greater risk indicated in the human model. These results suggest the need for integrated safety systems that have restraints that optimize the occupant's position during precrash braking and prior to impact.
NASA Astrophysics Data System (ADS)
Flores, Federico; Rondanelli, Roberto; Abarca, Accel; Diaz, Marcos; Querel, Richard
2012-09-01
Our group has designed, sourced and constructed a radiosonde/ground-station pair using inexpensive opensource hardware. Based on the Arduino platform, the easy to build radiosonde allows the atmospheric science community to test and deploy instrumentation packages that can be fully customized to their individual sensing requirements. This sensing/transmitter package has been successfully deployed on a tethered-balloon, a weather balloon, a UAV airplane, and is currently being integrated into a UAV quadcopter and a student-built rocket. In this paper, the system, field measurements and potential applications will be described. As will the science drivers of having full control and open access to a measurement system in an age when commercial solutions have become popular but are restrictive in terms of proprietary sensor specifications, "black-box" calibration operations or data handling routines, etc. The ability to modify and experiment with both the hardware and software tools is an essential part of the scientific process. Without an understanding of the intrinsic biases or limitations in your instruments and system, it becomes difficult to improve them or advance the knowledge in any given field.
Spectroscopy Made Easy: Evolution
NASA Astrophysics Data System (ADS)
Piskunov, Nikolai; Valenti, Jeff A.
2017-01-01
Context. The Spectroscopy Made Easy (SME) package has become a popular tool for analyzing stellar spectra, often in connection with large surveys or exoplanet research. SME has evolved significantly since it was first described in 1996, but many of the original caveats and potholes still haunt users. The main drivers for this paper are complexity of the modeling task, the large user community, and the massive effort that has gone into SME. Aims: We do not intend to give a comprehensive introduction to stellar atmospheres, but will describe changes to key components of SME: the equation of state, opacities, and radiative transfer. We will describe the analysis and fitting procedure and investigate various error sources that affect inferred parameters. Methods: We review the current status of SME, emphasizing new algorithms and methods. We describe some best practices for using the package, based on lessons learned over two decades of SME usage. We present a new way to assess uncertainties in derived stellar parameters. Results: Improvements made to SME, better line data, and new model atmospheres yield more realistic stellar spectra, but in many cases systematic errors still dominate over measurement uncertainty. Future enhancements are outlined.
Improved charge injection device and a focal plane interface electronics board for stellar tracking
NASA Technical Reports Server (NTRS)
Michon, G. J.; Burke, H. K.
1984-01-01
An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.
Lacroix, Fréderic; Archambault, Louis; Gingras, Luc; Guillot, Mathieu; Beddar, A Sam; Beaulieu, Luc
2008-08-01
A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility (+/-0.8%) in-field and good accuracy (+/-1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.
NASA Astrophysics Data System (ADS)
Testan, Peter R.
1987-04-01
A number of Color Hard Copy (CHC) market drivers are currently indicating strong growth in the use of CHC technologies for the business graphics marketplace. These market drivers relate to product, software, color monitors and color copiers. The use of color in business graphics allows more information to be relayed than is normally the case in a monochrome format. The communicative powers of full-color computer generated output in the business graphics application area will continue to induce end users to desire and require color in their future applications. A number of color hard copy technologies will be utilized in the presentation graphics arena. Thermal transfer, ink jet, photographic and electrophotographic technologies are all expected to be utilized in the business graphics presentation application area in the future. Since the end of 1984, the availability of color application software packages has grown significantly. Sales revenue generated by business graphics software is expected to grow at a compound annual growth rate of just over 40 percent to 1990. Increased availability of packages to allow the integration of text and graphics is expected. Currently, the latest versions of page description languages such as Postscript, Interpress and DDL all support color output. The use of color monitors will also drive the demand for color hard copy in the business graphics market place. The availability of higher resolution screens is allowing color monitors to be easily used for both text and graphics applications in the office environment. During 1987, the sales of color monitors are expected to surpass the sales of monochrome monitors. Another major color hard copy market driver will be the color copier. In order to take advantage of the communications power of computer generated color output, multiple copies are required for distribution. Product introductions of a new generation of color copiers is now underway with additional introductions expected during 1987. The color hard copy market continues to be in a state of constant change, typical of any immature market. However, much of the change is positive. During 1985, the color hard copy market generated 1.2 billion. By 1990, total market revenue is expected to exceed 5.5 billion. The business graphics CHC application area is expected to grow at a compound annual growth rate greater than 40 percent to 1990.
Detection of solder bump defects on a flip chip using vibration analysis
NASA Astrophysics Data System (ADS)
Liu, Junchao; Shi, Tielin; Xia, Qi; Liao, Guanglan
2012-03-01
Flip chips are widely used in microelectronics packaging owing to the high demand of integration in IC fabrication. Solder bump defects on flip chips are difficult to detect, because the solder bumps are obscured by the chip and substrate. In this paper a nondestructive detection method combining ultrasonic excitation with vibration analysis is presented for detecting missing solder bumps, which is a typical defect in flip chip packaging. The flip chip analytical model is revised by considering the influence of spring mass on mechanical energy of the system. This revised model is then applied to estimate the flip chip resonance frequencies. We use an integrated signal generator and power amplifier together with an air-coupled ultrasonic transducer to excite the flip chips. The vibrations are measured by a laser scanning vibrometer to detect the resonance frequencies. A sensitivity coefficient is proposed to select the sensitive resonance frequency order for defect detection. Finite element simulation is also implemented for further investigation. The results of analytical computation, experiment, and simulation prove the efficacy of the revised flip chip analytical model and verify the effectiveness of this detection method. Therefore, it may provide a guide for the improvement and innovation of the flip chip on-line inspection systems.
Access to CAMAC from VxWorks and UNIX in DART
DOE Office of Scientific and Technical Information (OSTI.GOV)
Streets, J.; Meadows, J.; Moore, C.
1996-02-01
All High Energy Physics experiments at Fermilab include CAMAC modules which need to be read out for each triggered event. There is also a need to access CAMAC modules for control and monitoring of the experiment. As part of the DART Project the authors have developed a package of software for CAMAC access from UNIX and VxWorks platforms, with support for several hardware interfaces. The authors report on developments for the CES CBD8210 VME to parallel CAMAC, the Hytec VSD2992 VME to serial CAMAC and Jorway 411S SCSI to parallel and serial CAMAC branch drivers, and give a summary ofmore » the timings obtained.« less
NASA Astrophysics Data System (ADS)
Harkness, Linda L.; Sjoberg, Eric S.
1996-06-01
The Georgia Tech Research Institute, sponsored by the Warner Robins Air Logistics Center, has developed an approach for efficiently postulating and evaluating methods for extending the life of radars and other avionics systems. The technique identified specific assemblies for potential replacement and evaluates the system level impact, including performance, reliability and life-cycle cost of each action. The initial impetus for this research was the increasing obsolescence of integrated circuits contained in the AN/APG-63 system. The operational life of military electronics is typically in excess of twenty years, which encompasses several generations of IC technology. GTRI has developed a systems approach to inserting modern technology components into older systems based upon identification of those functions which limit the system's performance or reliability and which are cost drivers. The presentation will discuss the above methodology and a technique for evaluating and ranking the different potential system upgrade options.
Second Breakdown of 18V Grounded Gate NMOS induced by the Kirk Effect under Electrostatic Discharge
NASA Astrophysics Data System (ADS)
Jeon, Byung-Chul; Lee, Seung-Chul; Han, Min-Koo
2003-09-01
Electrostatic Discharge (ESD) failure mechanisms of 18V grounded gate NMOS (GGNMOS) for liquid crystal display driver IC (LDI) applications are investigated and effects of layout design parameters on the ESD immunity level are analyzed. Experimental results show that 18V GGNMOS exhibits snapback characteristics and the ESD immunity level is rather high when XO (N-drift overlap over n+ source/drain) is sufficiently large, while GGNMOS does not exhibit the sustaining region and is very vulnerable to ESD stress when XO is relatively small. Simulation results show that the ESD failure mechanism of 18V GGNMOS could be the low-temperature second breakdown induced by the Kirk effect. It is inferred that a certain amount of XO is indispensable to ensure snapback characteristics and high ESD immunity level. Simulation results also show that the ESD immunity level is increased as drain contact to gate space (DCGS) is increased.
Who Adopts Improved Fuels and Cookstoves? A Systematic Review
Lewis, Jessica J.
2012-01-01
Background: The global focus on improved cookstoves (ICSs) and clean fuels has increased because of their potential for delivering triple dividends: household health, local environmental quality, and regional climate benefits. However, ICS and clean fuel dissemination programs have met with low rates of adoption. Objectives: We reviewed empirical studies on ICSs and fuel choice to describe the literature, examine determinants of fuel and stove choice, and identify knowledge gaps. Methods: We conducted a systematic review of the literature on the adoption of ICSs or cleaner fuels by households in developing countries. Results are synthesized through a simple vote-counting meta-analysis. Results: We identified 32 research studies that reported 146 separate regression analyses of ICS adoption (11 analyses) or fuel choice (135 analyses) from Asia (60%), Africa (27%), and Latin America (19%). Most studies apply multivariate regression methods to consider 7–13 determinants of choice. Income, education, and urban location were positively associated with adoption in most but not all studies. However, the influence of fuel availability and prices, household size and composition, and sex is unclear. Potentially important drivers such as credit, supply-chain strengthening, and social marketing have been ignored. Conclusions: Adoption studies of ICSs or clean energy are scarce, scattered, and of differential quality, even though global distribution programs are quickly expanding. Future research should examine an expanded set of contextual variables to improve implementation of stove programs that can realize the “win-win-win” of health, local environmental quality, and climate associated with these technologies. PMID:22296719
NASA Astrophysics Data System (ADS)
Ahi, Kiarash; Anwar, Mehdi
2016-04-01
This paper introduces a novel reconstruction approach for enhancing the resolution of the terahertz (THz) images. For this purpose the THz imaging equation is derived. According to our best knowledge we are reporting the first THz imaging equation by this paper. This imaging equation is universal for THz far-field imaging systems and can be used for analyzing, describing and modeling of these systems. The geometry and behavior of Gaussian beams in far-field region imply that the FWHM of the THz beams diverge as the frequencies of the beams decrease. Thus, the resolution of the measurement decreases in lower frequencies. On the other hand, the depth of penetration of THz beams decreases as frequency increases. Roughly speaking beams in sub 1.5 THz, are transmitted into integrated circuit (IC) packages and the similar packaged objects. Thus, it is not possible to use the THz pulse with higher frequencies in order to achieve higher resolution inspection of packaged items. In this paper, after developing the 3-D THz point spread function (PSF) of the scanning THz beam and then the THz imaging equation, THz images are enhanced through deconvolution of the THz PSF and THz images. As a result, the resolution has been improved several times beyond the physical limitations of the THz measurement setup in the far-field region and sub-Nyquist images have been achieved. Particularly, MSE and SSIḾ have been increased by 27% and 50% respectively. Details as small as 0.2 mm were made visible in the THz images which originally reveals no details smaller than 2.2 mm. In other words the resolution of the images has been increased by 10 times. The accuracy of the reconstructed images was proved by high resolution X-ray images.
Ultra-Reliable Digital Avionics (URDA) processor
NASA Astrophysics Data System (ADS)
Branstetter, Reagan; Ruszczyk, William; Miville, Frank
1994-10-01
Texas Instruments Incorporated (TI) developed the URDA processor design under contract with the U.S. Air Force Wright Laboratory and the U.S. Army Night Vision and Electro-Sensors Directorate. TI's approach couples advanced packaging solutions with advanced integrated circuit (IC) technology to provide a high-performance (200 MIPS/800 MFLOPS) modular avionics processor module for a wide range of avionics applications. TI's processor design integrates two Ada-programmable, URDA basic processor modules (BPM's) with a JIAWG-compatible PiBus and TMBus on a single F-22 common integrated processor-compatible form-factor SEM-E avionics card. A separate, high-speed (25-MWord/second 32-bit word) input/output bus is provided for sensor data. Each BPM provides a peak throughput of 100 MIPS scalar concurrent with 400-MFLOPS vector processing in a removable multichip module (MCM) mounted to a liquid-flowthrough (LFT) core and interfacing to a processor interface module printed wiring board (PWB). Commercial RISC technology coupled with TI's advanced bipolar complementary metal oxide semiconductor (BiCMOS) application specific integrated circuit (ASIC) and silicon-on-silicon packaging technologies are used to achieve the high performance in a miniaturized package. A Mips R4000-family reduced instruction set computer (RISC) processor and a TI 100-MHz BiCMOS vector coprocessor (VCP) ASIC provide, respectively, the 100 MIPS of a scalar processor throughput and 400 MFLOPS of vector processing throughput for each BPM. The TI Aladdim ASIC chipset was developed on the TI Aladdin Program under contract with the U.S. Army Communications and Electronics Command and was sponsored by the Advanced Research Projects Agency with technical direction from the U.S. Army Night Vision and Electro-Sensors Directorate.
VizieR Online Data Catalog: Time minima of EP Aur (Li+, 2015)
NASA Astrophysics Data System (ADS)
Li, H.-L.; Wei, J.-Y.; Yang, Y.-G.; Li, K.; Zhang, X.-B.
2015-07-01
From 2003 December to 2014 January, the photometry of EP Aur was performed by using the 60-cm telescope and the 85-cm telescope at the Xinglong station (XLs) of National Astronomical Observatories of China (NAOC), and the 1.0-m telescope at the Weihai Observatory (WHO) of Shandong University. The three telescopes were equipped with standard Johnson-Cousins UBVRcIc systems. All observed images were reduced by using the IMREDIMRED and APPHOTAPPHOT packages in IRAF in a standard fashion. The multi-color photometry of EP Aur was carried out on 2013 December 1, 2, 3, and 5, 2009 January 3, 4 and 5 using the 60-cm telescope at XLs. TYC 2420-434-1 and TYC 2420-193-1 were taken as the comparison and check stars respectively. (2 data files).
Silicon microelectronic field-emissive devices for advanced display technology
NASA Astrophysics Data System (ADS)
Morse, J. D.
1993-03-01
Field-emission displays (FED's) offer the potential advantages of high luminous efficiency, low power consumption, and low cost compared to AMLCD or CRT technologies. An LLNL team has developed silicon-point field emitters for vacuum triode structures and has also used thin-film processing techniques to demonstrate planar edge-emitter configurations. LLNL is interested in contributing its experience in this and other FED-related technologies to collaborations for commercial FED development. At LLNL, FED development is supported by computational capabilities in charge transport and surface/interface modeling in order to develop smaller, low-work-function field emitters using a variety of materials and coatings. Thin-film processing, microfabrication, and diagnostic/test labs permit experimental exploration of emitter and resistor structures. High field standoff technology is an area of long-standing expertise that guides development of low-cost spacers for FEDS. Vacuum sealing facilities are available to complete the FED production engineering process. Drivers constitute a significant fraction of the cost of any flat-panel display. LLNL has an advanced packaging group that can provide chip-on-glass technologies and three-dimensional interconnect generation permitting driver placement on either the front or the back of the display substrate.
Influence of Steering Control Devices Mounted in Cars for the Disabled on Passive Safety
NASA Astrophysics Data System (ADS)
Masiá, J.; Eixerés, B.; Dols, J. F.; Colomina, F. J.
2009-11-01
The purpose of this research is to analyze the influence of steering control devices for disabled people on passive safety. It is based on the advances made in the modelling and simulation of the driver position and in the suit verification test. The influence of these devices is studied through airbag deployment and/or its influence on driver safety. We characterize the different adaptations that are used in adapted cars that can be found mounted in vehicles in order to generating models that are verified by experimental test. A three dimensional design software package was used to develop the model. The simulations were generated using a dynamic simulation program employing LSDYNA finite elements. This program plots the geometry and assigns materials. The airbag is shaped, meshed and folded just as it is mounted in current vehicles. The thermodynamic model of expansion of gases is assigned and the contact interfaces are defined. Static tests were carried out on deployment of the airbag to contrast with and to validate the computational models and to measure the behaviour of the airbag when there are steering adaptations mounted in the vehicle.
Highly Efficient Small Form Factor LED Retrofit Lamp
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steven Allen; Fred Palmer; Ming Li
2011-09-11
This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent powermore » quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.« less
Wireless Interconnects for Intra-chip & Inter-chip Transmission
NASA Astrophysics Data System (ADS)
Narde, Rounak Singh
With the emergence of Internet of Things and information revolution, the demand of high performance computing systems is increasing. The copper interconnects inside the computing chips have evolved into a sophisticated network of interconnects known as Network on Chip (NoC) comprising of routers, switches, repeaters, just like computer networks. When network on chip is implemented on a large scale like in Multicore Multichip (MCMC) systems for High Performance Computing (HPC) systems, length of interconnects increases and so are the problems like power dissipation, interconnect delays, clock synchronization and electrical noise. In this thesis, wireless interconnects are chosen as the substitute for wired copper interconnects. Wireless interconnects offer easy integration with CMOS fabrication and chip packaging. Using wireless interconnects working at unlicensed mm-wave band (57-64GHz), high data rate of Gbps can be achieved. This thesis presents study of transmission between zigzag antennas as wireless interconnects for Multichip multicores (MCMC) systems and 3D IC. For MCMC systems, a four-chips 16-cores model is analyzed with only four wireless interconnects in three configurations with different antenna orientations and locations. Return loss and transmission coefficients are simulated in ANSYS HFSS. Moreover, wireless interconnects are designed, fabricated and tested on a 6'' silicon wafer with resistivity of 55O-cm using a basic standard CMOS process. Wireless interconnect are designed to work at 30GHz using ANSYS HFSS. The fabricated antennas are resonating around 20GHz with a return loss of less than -10dB. The transmission coefficients between antenna pair within a 20mm x 20mm silicon die is found to be varying between -45dB to -55dB. Furthermore, wireless interconnect approach is extended for 3D IC. Wireless interconnects are implemented as zigzag antenna. This thesis extends the work of analyzing the wireless interconnects in 3D IC with different configurations of antenna orientations and coolants. The return loss and transmission coefficients are simulated using ANSYS HFSS.
Inhaled corticosteroids in children with persistent asthma: effects on growth.
Zhang, Linjie; Prietsch, Sílvio O M; Ducharme, Francine M
2014-07-17
Treatment guidelines for asthma recommend inhaled corticosteroids (ICS) as first-line therapy for children with persistent asthma. Although ICS treatment is generally considered safe in children, the potential systemic adverse effects related to regular use of these drugs have been and continue to be a matter of concern, especially the effects on linear growth. To assess the impact of ICS on the linear growth of children with persistent asthma and to explore potential effect modifiers such as characteristics of available treatments (molecule, dose, length of exposure, inhalation device) and of treated children (age, disease severity, compliance with treatment). We searched the Cochrane Airways Group Specialised Register of trials (CAGR), which is derived from systematic searches of bibliographic databases including CENTRAL, MEDLINE, EMBASE, CINAHL, AMED and PsycINFO; we handsearched respiratory journals and meeting abstracts. We also conducted a search of ClinicalTrials.gov and manufacturers' clinical trial databases to look for potential relevant unpublished studies. The literature search was conducted in January 2014. Parallel-group randomised controlled trials comparing daily use of ICS, delivered by any type of inhalation device for at least three months, versus placebo or non-steroidal drugs in children up to 18 years of age with persistent asthma. Two review authors independently performed study selection, data extraction and assessment of risk of bias in included studies. We conducted meta-analyses using the Cochrane statistical package RevMan 5.2 and Stata version 11.0. We used the random-effects model for meta-analyses. We used mean differences (MDs) and 95% CIs as the metrics for treatment effects. A negative value for MD indicates that ICS have suppressive effects on linear growth compared with controls. We performed a priori planned subgroup analyses to explore potential effect modifiers, such as ICS molecule, daily dose, inhalation device and age of the treated child. We included 25 trials involving 8471 (5128 ICS-treated and 3343 control) children with mild to moderate persistent asthma. Six molecules (beclomethasone dipropionate, budesonide, ciclesonide, flunisolide, fluticasone propionate and mometasone furoate) [corrected] given at low or medium daily doses were used during a period of three months to four to six years. Most trials were blinded and over half of the trials had drop out rates of over 20%.Compared with placebo or non-steroidal drugs, ICS produced a statistically significant reduction in linear growth velocity (14 trials with 5717 participants, MD -0.48 cm/y, 95% CI -0.65 to -0.30, moderate quality evidence) and in the change from baseline in height (15 trials with 3275 participants; MD -0.61 cm/y, 95% CI -0.83 to -0.38, moderate quality evidence) during a one-year treatment period.Subgroup analysis showed a statistically significant group difference between six molecules in the mean reduction of linear growth velocity during one-year treatment (Chi² = 26.1, degrees of freedom (df) = 5, P value < 0.0001). The group difference persisted even when analysis was restricted to the trials using doses equivalent to 200 μg/d hydrofluoroalkane (HFA)-beclomethasone. Subgroup analyses did not show a statistically significant impact of daily dose (low vs medium), inhalation device or participant age on the magnitude of ICS-induced suppression of linear growth velocity during a one-year treatment period. However, head-to-head comparisons are needed to assess the effects of different drug molecules, dose, inhalation device or patient age. No statistically significant difference in linear growth velocity was found between participants treated with ICS and controls during the second year of treatment (five trials with 3174 participants; MD -0.19 cm/y, 95% CI -0.48 to 0.11, P value 0.22). Of two trials that reported linear growth velocity in the third year of treatment, one trial involving 667 participants showed similar growth velocity between the budesonide and placebo groups (5.34 cm/y vs 5.34 cm/y), and another trial involving 1974 participants showed lower growth velocity in the budesonide group compared with the placebo group (MD -0.33 cm/y, 95% CI -0.52 to -0.14, P value 0.0005). Among four trials reporting data on linear growth after treatment cessation, three did not describe statistically significant catch-up growth in the ICS group two to four months after treatment cessation. One trial showed accelerated linear growth velocity in the fluticasone group at 12 months after treatment cessation, but there remained a statistically significant difference of 0.7 cm in height between the fluticasone and placebo groups at the end of the three-year trial.One trial with follow-up into adulthood showed that participants of prepubertal age treated with budesonide 400 μg/d for a mean duration of 4.3 years had a mean reduction of 1.20 cm (95% CI -1.90 to -0.50) in adult height compared with those treated with placebo. Regular use of ICS at low or medium daily doses is associated with a mean reduction of 0.48 cm/y in linear growth velocity and a 0.61-cm change from baseline in height during a one-year treatment period in children with mild to moderate persistent asthma. The effect size of ICS on linear growth velocity appears to be associated more strongly with the ICS molecule than with the device or dose (low to medium dose range). ICS-induced growth suppression seems to be maximal during the first year of therapy and less pronounced in subsequent years of treatment. However, additional studies are needed to better characterise the molecule dependency of growth suppression, particularly with newer molecules (mometasone, ciclesonide), to specify the respective role of molecule, daily dose, inhalation device and patient age on the effect size of ICS, and to define the growth suppression effect of ICS treatment over a period of several years in children with persistent asthma.
Nutritional status and eating habits of bus drivers during the day and night.
Balieiro, Laura Cristina Tibiletti; Rossato, Luana Thomazetto; Waterhouse, Jim; Paim, Samantha Lemos; Mota, Maria Carliana; Crispim, Cibele Aparecida
2014-12-01
The aim of this study was to compare anthropometry and food intake patterns in bus drivers working during the day and night. One hundred and fifty males (81 night workers and 69 day workers) participated in the study. Dietary intake was assessed using a validated semi-quantitative food frequency questionnaire. Measurements of height, weight, waist circumference (WC), systolic and diastolic blood pressure, blood glucose, and lipid profile were obtained. A significant difference between groups was observed for mean WC (98.5 ± 10.7 cm in day workers versus 103.2 ± 9.7 cm in night workers; p = 0.005). Night workers had higher prevalence of being overweight and obese (BMI ≥ 25 kg/m(2)) than day workers (78.2% day workers versus 90.2% night workers; p = 0.004) and increased WC (>94 cm) (72.4% day workers versus 86.4% night workers; p = 0.03). Significant differences were found for meat consumption (2.3 servings ±0.9 for night workers versus 2.0 servings ±0.7 day workers, p = 0.04) and fruit intake (0.9 servings ±0.4 for night workers versus 0.7 servings for day workers ±0.5; p = 0.006). Night workers had a lower intake of vegetables than recommended compared to day workers (100 versus 92.7%, respectively, p = 0.01) and higher intake of oil (40.7 versus 24.6%, p = 0.03). Multivariate logistic regression analysis indicated that night work was associated with being overweight (OR = 2.94, 95% IC: 1.14-7.66, p = 0.03) and abnormal values of WC (OR = 2.82, 95% IC: 1.20-6.69, p = 0.009) after adjusting for potential confounders. It is concluded that night workers had a higher prevalence and risk of being overweight/obese and increased WC compared with day workers. Night workers also presented a higher proportion of inappropriate intakes of food groups when compared to day workers, even though both groups were eating poor diets. These results demonstrate the need of lifestyle-intervention programs in these workers.
Tritium pellet injector for the tokamak fusion test reactor
NASA Astrophysics Data System (ADS)
Gouge, M. J.; Baylor, L. R.; Combs, S. K.; Fisher, P. W.; Foust, C. R.; Milora, S. L.
The tritium pellet injector (TPI) for the Tokamak Fusion Test Reactor (TFTR) will provide a tritium pellet fueling capability with pellet speeds in the 1- to 3-km/s range for the TFTR deuterium-tritium (D-T) plasma phase. An existing deuterium pellet injector (DPI) was modified at Oak Ridge National Laboratory (ORNL) to provide a four-shot, tritium-compatible, pipe-gun configuration with three upgraded single-stage pneumatic guns and a two-stage light gas gun driver. The TPI was designed for frozen pellets ranging in size from 3 to 4 mm in diameter in arbitrarily programmable firing sequences at tritium pellet speeds up to approximately 1.5 km/s for the three single-stage drivers and 2.5 to 3 km/s for the two-stage driver. Injector operation is controlled by a programmable logic controller (PLC). The new pipe-gun injector assembly was installed in the modified DPI guard vacuum box, and modifications were also made to the internals of the DPI vacuum injection line, including a new pellet diagnostics package. Assembly of these modified parts with existing DPI components was then completed and the TPI was tested at ORNL with deuterium pellets. Results of the testing program at ORNL are described. The TPI has been installed and operated on TFTR in support of the FY-92 deuterium plasma run period. In 1993, the tritium pellet injector will be retrofitted with a D-T fuel manifold and tritium gloveboxes and integrated into TFTR tritium processing systems to provide full tritium pellet capability.
NASA Astrophysics Data System (ADS)
Xue, L.; Firl, G.; Zhang, M.; Jimenez, P. A.; Gill, D.; Carson, L.; Bernardet, L.; Brown, T.; Dudhia, J.; Nance, L. B.; Stark, D. R.
2017-12-01
The Global Model Test Bed (GMTB) has been established to support the evolution of atmospheric physical parameterizations in NCEP global modeling applications. To accelerate the transition to the Next Generation Global Prediction System (NGGPS), a collaborative model development framework known as the Common Community Physics Package (CCPP) is created within the GMTB to facilitate engagement from the broad community on physics experimentation and development. A key component to this Research to Operation (R2O) software framework is the Interoperable Physics Driver (IPD) that hooks the physics parameterizations from one end to the dynamical cores on the other end with minimum implementation effort. To initiate the CCPP, scientists and engineers from the GMTB separated and refactored the GFS physics. This exercise demonstrated the process of creating IPD-compliant code and can serve as an example for other physics schemes to do the same and be considered for inclusion into the CCPP. Further benefits to this process include run-time physics suite configuration and considerably reduced effort for testing modifications to physics suites through GMTB's physics test harness. The implementation will be described and the preliminary results will be presented at the conference.
McCarthy, K S; Parker, M; Ameerally, A; Drake, S L; Drake, M A
2017-08-01
Fluid milk consumption has declined for decades while consumption of nondairy alternatives has increased. A better understanding of why consumers purchase fluid milk or nondairy alternatives is needed to assist increased sales of milk or maintain sales without further decline. The objective of this study was to determine the extrinsic attributes that drive purchase within each product category. The second objective was to determine the personal values behind the purchase of each beverage type to give further understanding why particular attributes are important. An online conjoint survey was launched with 702 dairy consumers, 172 nondairy consumers, and 125 consumers of both beverages. Individual means-end chain interviews were conducted with fluid milk consumers (n = 75), plant-based alternative consumers (n = 68), and consumers of both beverages (n = 78). Fat content was the most important attribute for dairy milk followed by package size and label claims. Consumers of fluid milk preferred 1 or 2% fat content, gallon, or half-gallon packaging, conventionally pasteurized store-brand milk. Sugar level was the most important attribute for plant-based beverages, followed by plant source and package size. Almond milk was the most desirable plant source, and half-gallon packaging was the most preferred packaging. Means-end chain interviews results suggested that maintaining a balanced diet and healthy lifestyle was important to all consumer groups. Lactose free was an important attribute for plant-based alternative consumers and consumers of both dairy and nondairy. A distinguishing characteristic of those who only drank nondairy plant-based alternatives was that plant-based beverages contributed to a goal to consume less animal products, beliefs about animal mistreatment, and perceived lesser effect on the environment than fluid milk. Unique to fluid milk consumers was that fluid milk was perceived as a staple food item. These results suggest that the dairy industry should focus on the nutrition value of milk and educating consumers about misconceptions regarding dairy milk. Future beverage innovation should include the development of lactose-free milk that is also appealing to consumers in flavor. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Use and disclosure of health information and protection of patient privacy in Taiwan.
Liu, Han-Hsi
2010-03-01
This paper examines Taiwan's current regulatory system for the use of healthcare information from the viewpoint of patient privacy protection. The author proposes a patient-centered, cooperative system centered on the "traffic light theory", as a solution to the potential conflict between the use of healthcare information and the protection of patient privacy. Taiwan, a country with a national healthcare insurance program and state-of-the-art electronic technology, takes a distinctive approach to the protection of patient privacy. On January 1st, 2004, the Bureau of National Health Insurance (BNHI) implemented a comprehensive embedded integrated circuit (IC) card, which puts the wide-ranging health information of its 22 million beneficiaries online to facilitate review of use and disclosure. It is well understood that healthcare information is of a personal and sensitive nature, demanding stringent privacy protection. Nevertheless, there is no denying the potential benefit of using personal health information (PHI) to achieve public good, especially in the area of cost containment. The comprehensive e-health system in Taiwan greatly facilitates copying, transmission, and use of PHI, but does the regulatory system provide enough safeguards for patient privacy? Because the law in Taiwan does not provide clear standards for the use and disclosure of healthcare information, healthcare providers are either too conservative or too aggressive. While most healthcare providers keep their oath of confidentiality, some rogue members severely abuse patient privacy. This paper proposes a "traffic-light system" to remedy this situation. Flashing yellow lights allow aggressive drivers to ignore others, while causing overly cautious drivers to be too hesitant. The author contends that clear standards should have been established for healthcare providers. Like car drivers, healthcare providers need red and green traffic signals. The law should indicate, through workable privacy regulations and guidelines, when the light is red or green-when to stop or to advance.
System-on-Chip Considerations for Heterogeneous Integration of CMOS and Fluidic Bio-Interfaces.
Datta-Chaudhuri, Timir; Smela, Elisabeth; Abshire, Pamela A
2016-12-01
CMOS chips are increasingly used for direct sensing and interfacing with fluidic and biological systems. While many biosensing systems have successfully combined CMOS chips for readout and signal processing with passive sensing arrays, systems that co-locate sensing with active circuits on a single chip offer significant advantages in size and performance but increase the complexity of multi-domain design and heterogeneous integration. This emerging class of lab-on-CMOS systems also poses distinct and vexing technical challenges that arise from the disparate requirements of biosensors and integrated circuits (ICs). Modeling these systems must address not only circuit design, but also the behavior of biological components on the surface of the IC and any physical structures. Existing tools do not support the cross-domain simulation of heterogeneous lab-on-CMOS systems, so we recommend a two-step modeling approach: using circuit simulation to inform physics-based simulation, and vice versa. We review the primary lab-on-CMOS implementation challenges and discuss practical approaches to overcome them. Issues include new versions of classical challenges in system-on-chip integration, such as thermal effects, floor-planning, and signal coupling, as well as new challenges that are specifically attributable to biological and fluidic domains, such as electrochemical effects, non-standard packaging, surface treatments, sterilization, microfabrication of surface structures, and microfluidic integration. We describe these concerns as they arise in lab-on-CMOS systems and discuss solutions that have been experimentally demonstrated.
Standardizing Imperata cylindrica--source material for quality allergen preparations.
Bijli, Kaiser M; Singh, B P; Sridhara, Susheela; Gaur, S N; Arora, Naveen
2002-02-01
Tropical countries experience wide variations in daytime temperature and relative humidity. This affects the quality of the source material used for allergen extracts. The present study was undertaken to standardize the processing and preservation conditions of Imperata cylindrica grass pollen. I. cylindrica (Ic) inflorescence were freeze-dried, pollens sieved out and stored at -70 degrees C (IcA). Alternatively, the inflorescence were dried at room temperature and then at 37 degrees C, pollens sieved out and stored at 4 degrees C (IcB). The extracts prepared in PBS were analyzed in vivo by skin tests and in vitro by immunochemical methods. Reduced SDS-PAGE revealed 37 protein bands in IcA extract and 23 in IcB extract. IgE immunoblot with a pool of sera from Ic hypersensitive patients showed 30 allergenic bands in IcA and 14 in IcB. Immunoblot using anti-Ic rabbit sera revealed 33 antigenic bands in IcA and 22 in IcB. In both blots, the IcA extract exhibited sharp bands and the IcB extract exhibited diffuse bands. ELISA, ELISA inhibition and skin test procedures showed that IcA extracts had a higher potency than IcB extracts. Extracts prepared from -70 degrees C processed and preserved pollens (IcA) are allergenically more potent and contain a greater number of major and minor allergens than IcB extracts.
High-Temperature High-Power Packaging Techniques for HEV Traction Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barlow, F.D.; Elshabini, A.
A key issue associated with the wider adoption of hybrid-electric vehicles (HEV) and plug in hybrid-electric vehicles (PHEV) is the implementation of the power electronic systems that are required in these products [1]. To date, many consumers find the adoption of these technologies problematic based on a financial analysis of the initial cost versus the savings available from reduced fuel consumption. Therefore, one of the primary industry goals is the reduction in the price of these vehicles relative to the cost of traditional gasoline powered vehicles. Part of this cost reduction must come through optimization of the power electronics requiredmore » by these vehicles. In addition, the efficiency of the systems must be optimized in order to provide the greatest range possible. For some drivers, any reduction in the range associated with a potential HEV or PHEV solution in comparison to a gasoline powered vehicle represents a significant barrier to adoption and the efficiency of the power electronics plays an important role in this range. Likewise, high efficiencies are also important since lost power further complicates the thermal management of these systems. Reliability is also an important concern since most drivers have a high level of comfort with gasoline powered vehicles and are somewhat reluctant to switch to a less proven technology. Reliability problems in the power electronics or associated components could not only cause a high warranty cost to the manufacturer, but may also taint these technologies in the consumer's eyes. A larger vehicle offering in HEVs is another important consideration from a power electronics point of view. A larger vehicle will need more horsepower, or a larger rated drive. In some ways this will be more difficult to implement from a cost and size point of view. Both the packaging of these modules and the thermal management of these systems at competitive price points create significant challenges. One way in which significant cost reduction of these systems could be achieved is through the use of a single coolant loop for both the power electronics as well as the internal combustion engine (ICE) [2]. This change would reduce the complexity of the cooling system which currently relies on two loops to a single loop [3]. However, the current nominal coolant temperature entering these inverters is 65 C [3], whereas a normal ICE coolant temperature would be much higher at approximately 100 C. This change in coolant temperature significantly increases the junction temperatures of the devices and creates a number of challenges for both device fabrication and the assembly of these devices into inverters and converters for HEV and PHEV applications. With this change in mind, significant progress has been made on the use of SiC devices for inverters that can withstand much higher junction temperatures than traditional Si based inverters [4,5,6]. However, a key problem which the single coolant loop and high temperature devices is the effective packaging of these devices and related components into a high temperature inverter. The elevated junction temperatures that exist in these modules are not compatible with reliable inverters based on existing packaging technology. This report seeks to provide a literature survey of high temperature packaging and to highlight the issues related to the implementation of high temperature power electronic modules for HEV and PHEV applications. For purposes of discussion, it will be assumed in this report that 200 C is the targeted maximum junction temperature.« less
Light-induced voltage alteration for integrated circuit analysis
Cole, Jr., Edward I.; Soden, Jerry M.
1995-01-01
An apparatus and method are described for analyzing an integrated circuit (IC), The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC, The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs.
Light-induced voltage alteration for integrated circuit analysis
Cole, E.I. Jr.; Soden, J.M.
1995-07-04
An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.
Li, Lin; Yin, Heyu; Mason, Andrew J
2018-04-01
The integration of biosensors, microfluidics, and CMOS instrumentation provides a compact lab-on-CMOS microsystem well suited for high throughput measurement. This paper describes a new epoxy chip-in-carrier integration process and two planar metalization techniques for lab-on-CMOS that enable on-CMOS electrochemical measurement with multichannel microfluidics. Several design approaches with different fabrication steps and materials were experimentally analyzed to identify an ideal process that can achieve desired capability with high yield and low material and tool cost. On-chip electrochemical measurements of the integrated assembly were performed to verify the functionality of the chip-in-carrier packaging and its capability for microfluidic integration. The newly developed CMOS-compatible epoxy chip-in-carrier process paves the way for full implementation of many lab-on-CMOS applications with CMOS ICs as core electronic instruments.
Smart substrates: Making multi-chip modules smarter
NASA Astrophysics Data System (ADS)
Wunsch, T. F.; Treece, R. K.
1995-05-01
A novel multi-chip module (MCM) design and manufacturing methodology which utilizes active CMOS circuits in what is normally a passive substrate realizes the 'smart substrate' for use in highly testable, high reliability MCMS. The active devices are used to test the bare substrate, diagnose assembly errors or integrated circuit (IC) failures that require rework, and improve the testability of the final MCM assembly. A static random access memory (SRAM) MCM has been designed and fabricated in Sandia Microelectronics Development Laboratory in order to demonstrate the technical feasibility of this concept and to examine design and manufacturing issues which will ultimately determine the economic viability of this approach. The smart substrate memory MCM represents a first in MCM packaging. At the time the first modules were fabricated, no other company or MCM vendor had incorporated active devices in the substrate to improve manufacturability and testability, and thereby improve MCM reliability and reduce cost.
NASA Astrophysics Data System (ADS)
Cubillos, Patricio; Harrington, Joseph; Blecic, Jasmina; Stemm, Madison M.; Lust, Nate B.; Foster, Andrew S.; Rojo, Patricio M.; Loredo, Thomas J.
2014-11-01
Multi-wavelength secondary-eclipse and transit depths probe the thermo-chemical properties of exoplanets. In recent years, several research groups have developed retrieval codes to analyze the existing data and study the prospects of future facilities. However, the scientific community has limited access to these packages. Here we premiere the open-source Bayesian Atmospheric Radiative Transfer (BART) code. We discuss the key aspects of the radiative-transfer algorithm and the statistical package. The radiation code includes line databases for all HITRAN molecules, high-temperature H2O, TiO, and VO, and includes a preprocessor for adding additional line databases without recompiling the radiation code. Collision-induced absorption lines are available for H2-H2 and H2-He. The parameterized thermal and molecular abundance profiles can be modified arbitrarily without recompilation. The generated spectra are integrated over arbitrary bandpasses for comparison to data. BART's statistical package, Multi-core Markov-chain Monte Carlo (MC3), is a general-purpose MCMC module. MC3 implements the Differental-evolution Markov-chain Monte Carlo algorithm (ter Braak 2006, 2009). MC3 converges 20-400 times faster than the usual Metropolis-Hastings MCMC algorithm, and in addition uses the Message Passing Interface (MPI) to parallelize the MCMC chains. We apply the BART retrieval code to the HD 209458b data set to estimate the planet's temperature profile and molecular abundances. This work was supported by NASA Planetary Atmospheres grant NNX12AI69G and NASA Astrophysics Data Analysis Program grant NNX13AF38G. JB holds a NASA Earth and Space Science Fellowship.
Alloy Design Workbench-Surface Modeling Package Developed
NASA Technical Reports Server (NTRS)
Abel, Phillip B.; Noebe, Ronald D.; Bozzolo, Guillermo H.; Good, Brian S.; Daugherty, Elaine S.
2003-01-01
NASA Glenn Research Center's Computational Materials Group has integrated a graphical user interface with in-house-developed surface modeling capabilities, with the goal of using computationally efficient atomistic simulations to aid the development of advanced aerospace materials, through the modeling of alloy surfaces, surface alloys, and segregation. The software is also ideal for modeling nanomaterials, since surface and interfacial effects can dominate material behavior and properties at this level. Through the combination of an accurate atomistic surface modeling methodology and an efficient computational engine, it is now possible to directly model these types of surface phenomenon and metallic nanostructures without a supercomputer. Fulfilling a High Operating Temperature Propulsion Components (HOTPC) project level-I milestone, a graphical user interface was created for a suite of quantum approximate atomistic materials modeling Fortran programs developed at Glenn. The resulting "Alloy Design Workbench-Surface Modeling Package" (ADW-SMP) is the combination of proven quantum approximate Bozzolo-Ferrante-Smith (BFS) algorithms (refs. 1 and 2) with a productivity-enhancing graphical front end. Written in the portable, platform independent Java programming language, the graphical user interface calls on extensively tested Fortran programs running in the background for the detailed computational tasks. Designed to run on desktop computers, the package has been deployed on PC, Mac, and SGI computer systems. The graphical user interface integrates two modes of computational materials exploration. One mode uses Monte Carlo simulations to determine lowest energy equilibrium configurations. The second approach is an interactive "what if" comparison of atomic configuration energies, designed to provide real-time insight into the underlying drivers of alloying processes.
Wirschell, Maureen; Yang, Chun; Yang, Pinfen; Fox, Laura; Yanagisawa, Haru-aki; Kamiya, Ritsu; Witman, George B.; Porter, Mary E.
2009-01-01
Our goal is to understand the assembly and regulation of flagellar dyneins, particularly the Chlamydomonas inner arm dynein called I1 dynein. Here, we focus on the uncharacterized I1-dynein IC IC97. The IC97 gene encodes a novel IC without notable structural domains. IC97 shares homology with the murine lung adenoma susceptibility 1 (Las1) protein—a candidate tumor suppressor gene implicated in lung tumorigenesis. Multiple, independent biochemical assays determined that IC97 interacts with both α- and β-tubulin subunits within the axoneme. I1-dynein assembly mutants suggest that IC97 interacts with both the IC138 and IC140 subunits within the I1-dynein motor complex and that IC97 is part of a regulatory complex that contains IC138. Microtubule sliding assays, using axonemes containing I1 dynein but devoid of IC97, show reduced microtubule sliding velocities that are not rescued by kinase inhibitors, revealing a critical role for IC97 in I1-dynein function and control of dynein-driven motility. PMID:19420136
Price, David B; Colice, Gene; Israel, Elliot; Roche, Nicolas; Postma, Dirkje S; Guilbert, Theresa W; van Aalderen, Willem M C; Grigg, Jonathan; Hillyer, Elizabeth V; Thomas, Victoria; Martin, Richard J
2016-04-01
Asthma management guidelines recommend adding a long-acting β 2 -agonist (LABA) or increasing the dose of inhaled corticosteroid (ICS) as step-up therapy for patients with uncontrolled asthma on ICS monotherapy. However, it is uncertain which option works best, which ICS particle size is most effective, and whether LABA should be administered by separate or combination inhalers. This historical, matched cohort study compared asthma-related outcomes for patients (aged 12-80 years) prescribed step-up therapy as a ≥50% extrafine ICS dose increase or add-on LABA, via either a separate inhaler or a fine-particle ICS/LABA fixed-dose combination (FDC) inhaler. Risk-domain asthma control was the primary end-point in comparisons of cohorts matched for asthma severity and control during the baseline year. After 1:2 cohort matching, the increased extrafine ICS versus separate ICS+LABA cohorts included 3232 and 6464 patients, respectively, and the fine-particle ICS/LABA FDC versus separate ICS+LABA cohorts included 7529 and 15 058 patients, respectively (overall mean age 42 years; 61-62% females). Over one outcome year, adjusted OR (95% CI) for achieving asthma control were 1.25 (1.13-1.38) for increased ICS versus separate ICS+LABA and 1.06 (1.05-1.09) for ICS/LABA FDC versus separate ICS+LABA. For patients with asthma, increased dose of extrafine-particle ICS, or add-on LABA via ICS/LABA combination inhaler, is associated with significantly better outcomes than ICS+LABA via separate inhalers.
Gillooly, Kathleen M; Pulicicchio, Claudine; Pattoli, Mark A; Cheng, Lihong; Skala, Stacey; Heimrich, Elizabeth M; McIntyre, Kim W; Taylor, Tracy L; Kukral, Daniel W; Dudhgaonkar, Shailesh; Nagar, Jignesh; Banas, Dana; Watterson, Scott H; Tino, Joseph A; Fura, Aberra; Burke, James R
2017-01-01
Bruton's tyrosine kinase (BTK) regulates critical signal transduction pathways involved in the pathobiology of rheumatoid arthritis (RA) and other autoimmune disorders. BMS-986142 is a potent and highly selective reversible small molecule inhibitor of BTK currently being investigated in clinical trials for the treatment of both RA and primary Sjögren's syndrome. In the present report, we detail the in vitro and in vivo pharmacology of BMS-986142 and show this agent provides potent and selective inhibition of BTK (IC50 = 0.5 nM), blocks antigen receptor-dependent signaling and functional endpoints (cytokine production, co-stimulatory molecule expression, and proliferation) in human B cells (IC50 ≤ 5 nM), inhibits Fcγ receptor-dependent cytokine production from peripheral blood mononuclear cells, and blocks RANK-L-induced osteoclastogenesis. Through the benefits of impacting these important drivers of autoimmunity, BMS-986142 demonstrated robust efficacy in murine models of rheumatoid arthritis (RA), including collagen-induced arthritis (CIA) and collagen antibody-induced arthritis (CAIA). In both models, robust efficacy was observed without continuous, complete inhibition of BTK. When a suboptimal dose of BMS-986142 was combined with other agents representing the current standard of care for RA (e.g., methotrexate, the TNFα antagonist etanercept, or the murine form of CTLA4-Ig) in the CIA model, improved efficacy compared to either agent alone was observed. The results suggest BMS-986142 represents a potential therapeutic for clinical investigation in RA, as monotherapy or co-administered with agents with complementary mechanisms of action.
The scaling of performance and losses in miniature internal combustion engines
NASA Astrophysics Data System (ADS)
Menon, Shyam Kumar
Miniature glow ignition internal combustion (IC) piston engines are an off--the--shelf technology that could dramatically increase the endurance of miniature electric power supplies and the range and endurance of small unmanned air vehicles provided their overall thermodynamic efficiencies can be increased to 15% or better. This thesis presents the first comprehensive analysis of small (<500 g) piston engine performance. A unique dynamometer system is developed that is capable of making reliable measurements of engine performance and losses in these small engines. Methodologies are also developed for measuring volumetric, heat transfer, exhaust, mechanical, and combustion losses. These instruments and techniques are used to investigate the performance of seven single-cylinder, two-stroke, glow fueled engines ranging in size from 15 to 450 g (0.16 to 7.5 cm3 displacement). Scaling rules for power output, overall efficiency, and normalized power are developed from the data. These will be useful to developers of micro-air vehicles and miniature power systems. The data show that the minimum length scale of a thermodynamically viable piston engine based on present technology is approximately 3 mm. Incomplete combustion is the most important challenge as it accounts for 60-70% of total energy losses. Combustion losses are followed in order of importance by heat transfer, sensible enthalpy, and friction. A net heat release analysis based on in-cylinder pressure measurements suggest that a two--stage combustion process occurs at low engine speeds and equivalence ratios close to 1. Different theories based on burning mode and reaction kinetics are proposed to explain the observed results. High speed imaging of the combustion chamber suggests that a turbulent premixed flame with its origin in the vicinity of the glow plug is the primary driver of combustion. Placing miniature IC engines on a turbulent combustion regime diagram shows that they operate in the 'flamelet in eddy' regime whereas conventional--scale engines operate mostly in the 'wrinkled laminar flame sheet' regime. Taken together, the results show that the combustion process is the key obstacle to realizing the potential of small IC engines. Overcoming this obstacle will require new diagnostic techniques, measurements, combustion models, and high temperature materials.
Melvin, John W; Begeman, Paul C; Faller, Ronald K; Sicking, Dean L; McClellan, Scott B; Maynard, Edwin; Donegan, Michael W; Mallott, Annette M; Gideon, Thomas W
2006-11-01
Biomechanical analysis of Indy car crashes using on-board impact recorders (Melvin et al. 1998, Melvin et al. 2001) indicates that Indy car driver protection in high-energy crashes can be achieved in frontal, side, and rear crashes with severities in the range of 100 to 135 G peak deceleration and velocity changes in the range of 50 to 70 mph. These crashes were predominantly single-car impacts with the rigid concrete walls of oval tracks. This impressive level of protection was found to be due to the unique combination of a very supportive and tight-fitting cockpit-seating package, a six-point belt restraint system, and effective head padding with an extremely strong chassis that defines the seat and cockpit of a modern Indy car. In 2000 and 2001, a series of fatal crashes in stock car racing created great concern for improving the crash protection for drivers in those racecars. Unlike the Indy car, the typical racing stock car features a more spacious driver cockpit due to its resemblance to the shape of a passenger car. The typical racing seat used in stock cars did not have the same configuration or support characteristics of the Indy car seat, and five-point belt restraints were used. The tubular steel space frame chassis of a stock car also differs from an Indy car's composite chassis structure in both form and mechanical behavior. This paper describes the application of results of the biomechanical analysis of the Indy car crash studies to the unique requirements of stock car racing driver crash protection. Sled test and full-scale crash test data using both Hybrid III frontal crash anthropomorphic test devices (ATDs) and BioSID side crash ATDs for the purpose of evaluating countermeasures involving restraint systems, seats and head/neck restraints has been instrumental in guiding these developments. In addition, the development of deformable walls for oval tracks (the SAFER Barrier) is described as an adjunct to improved occupant restraint through control of the crash forces acting on a racing car. NASCAR (National Association for Stock Car Auto Racing, Inc) implemented crash recording in stock car racing in its three national series in 2002. Data from 2925 crashes from 2002 through the 2005 season are summarized in terms of crash severity, crash direction, injury outcome, and protective system performance.
Rabinovitz, Shiri; Kaufman, Yotam; Ludwig, Guy; Razin, Aharon; Shemer, Ruth
2012-01-01
The Prader-Willi syndrome/Angelman syndrome (PWS/AS) imprinted domain is regulated by a bipartite imprinting control center (IC) composed of a sequence around the SNRPN promoter (PWS-IC) and a 880-bp sequence located 35 kb upstream (AS-IC). The AS-IC imprint is established during gametogenesis and confers repression upon PWS-IC on the maternal allele. Mutation at PWS-IC on the paternal allele leads to gene silencing across the entire PWS/AS domain. This silencing implies that PWS-IC functions on the paternal allele as a bidirectional activator. Here we examine the mechanism by which PWS-IC activates the paternally expressed genes (PEGs) using transgenes that include the PWS-IC sequence in the presence or absence of AS-IC and NDN, an upstream PEG, as an experimental model. We demonstrate that PWS-IC is in fact an activator of NDN. This activation requires an unmethylated PWS-IC in the gametes and during early embryogenesis. PWS-IC is dispensable later in development. Interestingly, a similar activation of a nonimprinted gene (APOA1) was observed, implying that PWS-IC is a universal activator. To decipher the mechanism by which PWS-IC confers activation of remote genes, we performed methylated DNA immunoprecipitation (MeDIP) array analysis on lymphoblast cell lines that revealed dispersed, rather than continued differential methylation. However, chromatin conformation capture (3c) experiments revealed a physical interaction between PWS-IC and the PEGs, suggesting that activation of PEGs may require their proximity to PWS-IC. PMID:22529396
NASA Astrophysics Data System (ADS)
Jayarajan, Jayesh; Kumar, Nishant; Verma, Amarnath; Thaker, Ramkrishna
2016-05-01
Drive electronics for generating fast, bipolar clocks, which can drive capacitive loads of the order of 5-10nF are indispensable for present day Charge Coupled Devices (CCDs). Design of these high speed bipolar clocks is challenging because of the capacitive loads that have to be driven and a strict constraint on the rise and fall times. Designing drive electronics circuits for space applications becomes even more challenging due to limited number of available discrete devices, which can survive in the harsh radiation prone space environment. This paper presents the design, simulations and test results of a set of such high speed, bipolar clock drivers. The design has been tested under a thermal cycle of -15 deg C to +55 deg C under vacuum conditions and has been designed using radiation hardened components. The test results show that the design meets the stringent rise/fall time requirements of 50+/-10ns for Multiple Vertical CCD (VCCD) clocks and 20+/-5ns for Horizontal CCD (HCCD) clocks with sufficient design margins across full temperature range, with a pixel readout rate of 6.6MHz. The full design has been realized in flexi-rigid PCB with package volume of 140x160x50 mm3.
Coronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.
Fatone, Stefania; Dillon, Michael; Stine, Rebecca; Tillges, Robert
2014-01-01
Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly assigned socket conditions (IC and tissue compression) were assessed: (1) IC and high, (2) IC and medium, (3) IC and low, (4) no IC and high, (5) no IC and medium, and (6) no IC and low. For the six subjects in this study, there was a strong, negative relationship between comfort and changes in IC and tissue loading (rho = -0.89). With the ischium contained, tissue loading did not influence socket comfort (p = 0.47). With no IC, the socket was equally comfortable with high tissue loading (p = 0.36) but the medium (p = 0.04) and low (p = 0.02) tissue loading conditions decreased comfort significantly. Coronal plane hip moments, lateral trunk lean, step width, and walking speed were invariant to changes in IC and/or tissue loading. Our results suggest that in an IC socket, medial tissue loading mattered little in terms of comfort. Sockets without IC required high tissue loading to be as comfortable as those with IC, while suboptimal tissue loading compromised comfort.
Dihydropyrimidones: As novel class of β-glucuronidase inhibitors.
Ali, Farman; Khan, Khalid Mohammed; Salar, Uzma; Iqbal, Sarosh; Taha, Muhammad; Ismail, Nor Hadiani; Perveen, Shahnaz; Wadood, Abdul; Ghufran, Mehreen; Ali, Basharat
2016-08-15
Dihydropyrimidones 1-37 were synthesized via a 'one-pot' three component reaction according to well-known Biginelli reaction by utilizing Cu(NO3)2·3H2O as catalyst, and screened for their in vitro β-glucuronidase inhibitory activity. It is worth mentioning that amongst the active molecules, compounds 8 (IC50=28.16±.056μM), 9 (IC50=18.16±0.41μM), 10 (IC50=22.14±0.43μM), 13 (IC50=34.16±0.65μM), 14 (IC50=17.60±0.35μM), 15 (IC50=15.19±0.30μM), 16 (IC50=27.16±0.48μM), 17 (IC50=48.16±1.06μM), 22 (IC50=40.16±0.85μM), 23 (IC50=44.16±0.86μM), 24 (IC50=47.16±0.92μM), 25 (IC50=18.19±0.34μM), 26 (IC50=33.14±0.68μM), 27 (IC50=44.16±0.94μM), 28 (IC50=24.16±0.50μM), 29 (IC50=34.24±0.47μM), 31 (IC50=14.11±0.21μM) and 32 (IC50=9.38±0.15μM) found to be more potent than the standard d-saccharic acid 1,4-lactone (IC50=48.4±1.25μM). Molecular docking study was conducted to establish the structure-activity relationship (SAR) which demonstrated that a number of structural features of dihydropyrimidone derivatives were involved to exhibit the inhibitory potential. All compounds were characterized by spectroscopic techniques such as (1)H, (13)C NMR, EIMS and HREI-MS. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yu-Qian; Modjaz, Maryam; Bianco, Federica B., E-mail: YL1260@nyu.edu, E-mail: mmodjaz@nyu.edu
Super-luminous supernovae (SLSNe) are tremendously luminous explosions whose power sources and progenitors are highly debated. Broad-lined SNe Ic (SNe Ic-bl) are the only type of SNe that are connected with long-duration gamma-ray bursts (GRBs). Studying the spectral similarity and difference between the populations of hydrogen-poor SLSNe (SLSNe Ic) and of hydrogen-poor stripped-envelope core-collapse SNe, in particular SNe Ic and SNe Ic-bl, can provide crucial observations to test predictions of theories based on various power source models and progenitor models. In this paper, we collected all of the published optical spectra of 32 SLSNe Ic, 21 SNe Ic-bl, as well asmore » 17 SNe Ic, quantified their spectral features, constructed average spectra, and compared them in a systematic way using new tools we have developed. We find that SLSNe Ic and SNe Ic-bl, including those connected with GRBs, have comparable widths for their spectral features and average absorption velocities at all phases. Thus, our findings strengthen the connection between SLSNe Ic and GRBs. In particular, SLSNe Ic have average Fe ii λ 5169 absorption velocities of −15,000 ± 2600 km s{sup −1} at 10 days after peak, which are higher than those of SNe Ic by ∼7000 km s{sup −1} on average. SLSNe Ic also have significantly broader Fe ii λ 5169 lines than SNe Ic. Moreover, we find that such high absorption and width velocities of SLSNe Ic may be hard to explain with the interaction model, and none of the 13 SLSNe Ic with measured absorption velocities spanning over 10 days has a convincing flat velocity evolution, which is inconsistent with the magnetar model in one dimension. Lastly, we compare SN 2011kl, the first SN connected with an ultra-long GRB, with the mean spectrum of SLSNe Ic and of SNe Ic-bl.« less
Phenoxyacetohydrazide Schiff bases: β-glucuronidase inhibitors.
Jamil, Waqas; Perveen, Shagufta; Shah, Syed Adnan Ali; Taha, Muhammad; Ismail, Nor Hadiani; Perveen, Shahnaz; Ambreen, Nida; Khan, Khalid M; Choudhary, Muhammad I
2014-06-25
Phenoxyacetohydrazide Schiff base analogs 1-28 have been synthesized and their in vitro β-glucouoronidase inhibition potential studied. Compounds 1 (IC50=9.20±0.32 µM), 5 (IC50=9.47±0.16 µM), 7 (IC50=14.7±0.19 µM), 8 (IC50=15.4±1.56 µM), 11 (IC50=19.6±0.62 µM), 12 (IC50=30.7±1.49 µM), 15 (IC50=12.0±0.16 µM), 21 (IC50=13.7±0.40 µM) and 22 (IC50=22.0±0.14 µM) showed promising β-glucuronidase inhibition activity, better than the standard (D-saccharic acid-1,4-lactone, IC50=48.4±1.25 µM).
A survey of infection control teaching in U.S. dental schools.
Porteous, Nuala B; Bizra, Eamon; Cothron, Annaliese; Yeh, Chih-Ko
2014-02-01
This study was conducted to determine the content of infection control (IC) curricula, the extent of IC monitoring and compliance, and the number of bloodborne pathogen (BBP) exposures/year in U.S. dental schools. A questionnaire was emailed to persons responsible for predoctoral IC programs. The response rate was 60 percent. Most schools did not have an independent course and used classroom lectures and clinic demonstrations to teach IC. Schools with an IC committee were more likely to use online learning (p<0.05), utilize multiple teaching methods (p<0.05), issue written warnings for IC violations (p<0.0001), and use multiple disciplinary actions (p<0.005) than schools without an IC committee. Schools with an IC coordinator were less likely to issue grade reductions for IC violations than schools with no IC coordinator (p<0.05). Thirty-eight percent reported ≥ 16 BBP exposures/year, and 18 percent reported <5. There was significant correlation between BBP exposure incidents and large class size (p<0.005). Respondents were satisfied with their IC curriculum and perceived that dental students had a high level of IC compliance and satisfaction, along with staff IC promotion and compliance. The findings suggest that schools without an IC committee should consider its benefits. Further investigation of schools with high numbers of BBP exposures is recommended.
The Fabric for Frontier Experiments Project at Fermilab
NASA Astrophysics Data System (ADS)
Kirby, Michael
2014-06-01
The FabrIc for Frontier Experiments (FIFE) project is a new, far-reaching initiative within the Fermilab Scientific Computing Division to drive the future of computing services for experiments at FNAL and elsewhere. It is a collaborative effort between computing professionals and experiment scientists to produce an end-to-end, fully integrated set of services for computing on the grid and clouds, managing data, accessing databases, and collaborating within experiments. FIFE includes 1) easy to use job submission services for processing physics tasks on the Open Science Grid and elsewhere; 2) an extensive data management system for managing local and remote caches, cataloging, querying, moving, and tracking the use of data; 3) custom and generic database applications for calibrations, beam information, and other purposes; 4) collaboration tools including an electronic log book, speakers bureau database, and experiment membership database. All of these aspects will be discussed in detail. FIFE sets the direction of computing at Fermilab experiments now and in the future, and therefore is a major driver in the design of computing services worldwide.
1393 Ring Bus at JPL: Description and Status
NASA Technical Reports Server (NTRS)
Wysocky, Terry R.
2007-01-01
Completed Ring Bus IC V&V Phase - Ring Bus Test Plan Completed for SIM Project - Applicable to Other Projects Implemented a Avionics Bus Based upon the IEEE 1393 Standard - Excellent Starting Point for a General Purpose High-Speed Spacecraft Bus - Designed to Meet SIM Requirements for - Real-time deterministic, distributed systems. - Control system requirements - Fault detection and recovery Other JPL Projects Considering Implementation F'light Software Ring Bus Driver Module Began in 2006, Continues Participating in Standard Revision. Search for Earth-like planets orbiting nearby stars and measure the masses and orbits of the planets it finds. Survey 2000 nearby stars for planetary systems to learn whether our Solar System is unusual, or typical. Make a new catalog of star position 100 times more accurate than current measurements. Learn how our galaxy formed and will evolve by studying the dynamics of its stars. Critically test models of exactly how stars shine, including exotic objects like black holes, neutron stars and white dwarfs.
Wide-temperature integrated operational amplifier
NASA Technical Reports Server (NTRS)
Mojarradi, Mohammad (Inventor); Levanas, Greg (Inventor); Chen, Yuan (Inventor); Cozy, Raymond S. (Inventor); Greenwell, Robert (Inventor); Terry, Stephen (Inventor); Blalock, Benjamin J. (Inventor)
2009-01-01
The present invention relates to a reference current circuit. The reference circuit comprises a low-level current bias circuit, a voltage proportional-to-absolute temperature generator for creating a proportional-to-absolute temperature voltage (VPTAT), and a MOSFET-based constant-IC regulator circuit. The MOSFET-based constant-IC regulator circuit includes a constant-IC input and constant-IC output. The constant-IC input is electrically connected with the VPTAT generator such that the voltage proportional-to-absolute temperature is the input into the constant-IC regulator circuit. Thus the constant-IC output maintains the constant-IC ratio across any temperature range.
Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bounds, John Alan
This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.
Lightweight Integrated Solar Array (LISA): Providing Higher Power to Small Spacecraft
NASA Technical Reports Server (NTRS)
Johnson, Les; Carr, John; Fabisinski, Leo; Lockett, Tiffany Russell
2015-01-01
Affordable and convenient access to electrical power is essential for all spacecraft and is a critical design driver for the next generation of smallsats, including CubeSats, which are currently extremely power limited. The Lightweight Integrated Solar Array (LISA), a concept designed, prototyped, and tested at the NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama provides an affordable, lightweight, scalable, and easily manufactured approach for power generation in space. This flexible technology has many wide-ranging applications from serving small satellites to providing abundant power to large spacecraft in GEO and beyond. By using very thin, ultraflexible solar arrays adhered to an inflatable or deployable structure, a large area (and thus large amount of power) can be folded and packaged into a relatively small volume.
Solid-State Powered X-band Accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, Mohamed A.K.; Nann, Emilio A.; Dolgashev, Valery A.
2017-03-06
In this report we disseminate the hot test results of an X-band 100-W solid state amplifier chain for linear accelerator (linac) applications. Solid state power amplifiers have become increasingly attractive solutions for achieving high power in radar and maritime applications. Here the performance of solid state amplifiers when driving an RF cavity is investigated. Commercially available, matched and fully-packaged GaN on SiC HEMTs are utilized, comprising a wideband driver stage and two power stages. The amplifier chain has a high poweradded- efficiency and is able to supply up to ~1.2 MV/m field gradient at 9.2 GHz in a simple testmore » cavity, with a peak power exceeding 100 W. These findings set forth the enabling technology for solid-state powered linacs.« less
High frequency optical communications; Proceedings of the Meeting, Cambridge, MA, Sept. 23, 24, 1986
NASA Astrophysics Data System (ADS)
Ramer, O. Glenn; Sierak, Paul
Topics discussed in this volume include systems and applications, detectors, sources, and coherent communications. Papers are presented on RF fiber optic links for avionics applications, fiber optics and optoelectronics for radar and electronic warfare applications, symmetric coplanar electrodes for high-speed Ti:LiNbO3 devices, and surface wave electrooptic modulator. Attention is given to X-band RF fiber-optic links, fiber-optic links for microwave signal transmission, GaAs monolithic receiver and laser driver for GHz transmission rates, and monolithically integrable high-speed photodetectors. Additional papers are on irregular and chaotic behavior of semiconductor lasers under modulation, high-frequency laser package for microwave optical communications, receiver modeling for coherent light wave communications, and polarization sensors and controllers for coherent optical communication systems.
NASA Astrophysics Data System (ADS)
Peng, Yiya; Xi, Guangcheng; Zhong, Chang; Wang, Linping; Lu, Jun; Sun, Ximeng; Zhu, Lu; Han, Qikun; Chen, Lin; Shi, Lei; Sun, Mei; Li, Qianrong; Yu, Min; Yin, Mingwen
2009-08-01
Tochilinite represents a mineral group of ordered mixed-layer structures containing alternating Fe 1-xS layers with mackinawite-like structure and metal hydroxide layers with Mg(OH) 2-like structure. In this article, we report the preparation of a series of tochilinite-originated (or Fe 1-xS-based) intercalation compounds (ICs). According to their preparation procedures, these ICs can be divided into four kinds. The first kind of IC was sodium tochilinite (Na-tochilinite), which was prepared by the hydrothermal reaction of metallic Fe particles with concentrated Na 2S·9H 2O aqueous solutions. The hydroxide layer of the Na-tochilinite was a mixed hydroxide of Na + ions along with a certain amount of Fe 2+ ions. When the hydroxide layer of the Na-tochilinite completely dissolved in aqueous solutions, a Fe-deficient mackinawite-like phase Fe 1-xS was obtained, which was probably an electron-deficient p-type conductor. The second kind of ICs was prepared by 'low-temperature direct intercalation in aqueous solutions, using Na-tochilinite as a parental precursor. When the Na-tochilinite was ultrasonicated in aqueous solutions containing Lewis basic complexing agents (like NH 3, N 2H 4, 2,2'-bipyridine (bipy), and 1,10-phenanthroline (phen)), the Na + ions of the Na-tochilinite were removed and the Lewis basic complexing agents entered the hydroxide layer of the Na-tochilinite and became coordinated with the Fe 2+ ions, and the second kind of ICs was thus produced. The second kind of ICs includes NH 3 IC, N 2H 4 IC, N 2H 4-NH 3 IC, [Fe(bipy) 3] 2+-containing IC and [Fe(phen) 3] 2+-containing IC. The third kind of ICs, which includes NH 3 IC, N 2H 4-NH 3 IC and N 2H 4-LiOH (NaOH) IC, was prepared by the hydrothermal reaction of metallic Fe particles with (NH 4) 2S aqueous solution, S (elemental) + N 2H 4·H 2O aqueous solution, and S + N 2H 4·H 2O + LiOH (NaOH) aqueous solution, respectively. The third kind of ICs has a close relationship with the second kind of ICs both in composition and structure. The fourth kind of ICs was prepared by the oxidation and reduction of some of the N 2H 4-containing ICs mentioned above, which include N 2H 2 (diazene or diimide) IC, N 2 (dinitrogen) IC and NH 3 IC. The N 2H 2 IC was prepared by mild air oxidation of the N 2H 4-LiOH IC. The N 2 IC was prepared by strong air oxidation of the N 2H 4-LiOH IC, however, we have not been able to separate the pure phase N 2 IC. Hydrothermal reduction of the N 2H 4 IC made by the direct intercalation method in strong reducing environment by H 2S + Fe (metal) led to the production of the NH 3 IC of the fourth kind of ICs. The NH 3 ICs prepared by the three methods had similar compositions and structures. As almost all the ICs reported in this paper were extremely sensitive both to air and to the electron beam, they were mainly characterized by XRD. The properties and interrelationships (or mutual transformations) of the Fe 1-xS-based ICs revealed novel chemistry occurring in the sub-nanoscopic space between the micrometer- to nanometer-sized electron-deficient Fe 1-xS layers. An important finding of this novel chemistry was that the Fe 1-xS-based ICs tended to oxidize or reduce the intercalated species when the redox state of their environments varied. The results of our experiments potentially have many cosmochemical implications. The most important implication is that our experimental results, along with previous studies, strongly suggested that some of the ammonium salts, ammonia and carbonates existing in the matrix of the CM carbonaceous chondrites may have been formed by abiotic reactions employing molecular nitrogen as the nitrogen source and carbon monoxide as the carbon source and iron sulfide and/or iron hydroxide as catalysts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hargis, Kenneth Marshall
A large wildfire called the Las Conchas Fire burned large areas near Los Alamos National Laboratory (LANL) in 2011 and heightened public concern and news media attention over transuranic (TRU) waste stored at LANL’s Technical Area 54 (TA-54) Area G waste management facility. The removal of TRU waste from Area G had been placed at a lower priority in budget decisions for environmental cleanup at LANL because TRU waste removal is not included in the March 2005 Compliance Order on Consent (Reference 1) that is the primary regulatory driver for environmental cleanup at LANL. The Consent Order is a settlementmore » agreement between LANL and the New Mexico Environment Department (NMED) that contains specific requirements and schedules for cleaning up historical contamination at the LANL site. After the Las Conchas Fire, discussions were held by the U.S. Department of Energy (DOE) with the NMED on accelerating TRU waste removal from LANL and disposing it at the Waste Isolation Pilot Plant (WIPP). This report summarizes available information on the origin, configuration, and composition of the waste containers within the Tritium Packages and 17th RH Canister categories; their physical and radiological characteristics; the results of the radioassays; and potential issues in retrieval and processing of the waste containers.« less
Blasier, Kiev R.; Humsi, Michael K.; Ha, Junghoon; Ross, Mitchell W.; Smiley, W. Russell; Inamdar, Nirja A.; Mitchell, David J.; Lo, Kevin W.-H.; Pfister, K. Kevin
2014-01-01
Cytoplasmic dynein is a multi-subunit motor protein responsible for intracellular cargo transport toward microtubule minus ends. There are multiple isoforms of the dynein intermediate chain (DYNC1I, IC) which is encoded by two genes. One way to regulate cytoplasmic dynein is by IC phosphorylation. The IC-2C isoform is expressed in all cells and the functional significance of phosphorylation on IC-2C serine 84 was investigated using live cell imaging of fluorescent protein-tagged wild type IC-2C (WT) and phospho- and dephospho-mimic mutant isoforms in axonal transport model systems. Both mutations modulated dynein functional properties. The dephospho-mimic mutant IC-2C S84A had greater co-localization with mitochondria than IC-2C wild-type (WT) or the phospho-mimic mutant IC-2C S84D. The dephospho-mimic mutant IC-2C S84A was also more likely to be motile than the phospho-mimic mutant IC-2C S84D or IC-2C WT. In contrast, the phospho-mimic mutant IC-2C S84D mutant was more likely to move in the retrograde direction than was the IC-2C S84A mutant. The phospho-mimic IC-2C S84D was also as likely as IC-2C WT to co-localize with mitochondria. Both the S84D phospho- and S84A, dephospho-mimic mutants were found to be capable of microtubule minus end directed (retrograde) movement in axons. They were also observed to be passively transported in the anterograde direction. These data suggest that the IC-2C S84 has a role in modulating dynein properties. PMID:24798412
Liu, Li; Li, Wei; Wei, Ke; Cao, Jun; Luo, Jie; Wang, Bin; Min, Su
2013-06-01
Inhaled anesthetics increase the incidence of postoperative residual neuromuscular blockade, and the mechanism is still unclear. We have investigated the synergistic effect of low-concentration inhaled anesthetics and rocuronium on inhibition of the inward current of the adult-type muscle nicotinic acetylcholine receptor (ε-nAChR). Adult-type mouse muscle ε-nAChR was expressed in HEK293 cells by liposome transfection. The inward current of the ε-nAChR was activated by use of 10 μmol/L acetylcholine alone or in combination with different concentrations of sevoflurane, isoflurane, or rocuronium. The concentration-response curves of five cells were constructed, and the data yielded the 5, 25, and 50 % inhibitory concentrations (IC5, IC25, and IC50, respectively) for single-drug application. Subsequently, the functional channels were perfused by adding 0.5 IC5 of either sevoflurane or isoflurane (aqueous concentrations 140 and 100 μmol/L, respectively) to the solution, followed by addition of IC5, IC25, or IC50 rocuronium. The amount of inhibition was calculated to quantify their synergistic effect. The inhibitory effect of rocuronium was enhanced by sevoflurane or isoflurane in a concentration-dependent manner. Sevoflurane or isoflurane (0.5 IC5) with rocuronium at IC5, IC25, and IC50 synergistically inhibited the current amplitude of adult-type muscle ε-nAChR. When the IC5 of rocuronium was used, isoflurane had a stronger synergistic effect than sevoflurane (p < 0.05). When rocuronium was applied at higher concentrations (IC25 and IC50), sevoflurane had an effect similar to that of isoflurane. For both inhaled anesthetics, the synergistic effect was more intense for rocuronium at IC5 than for rocuronium at IC25 or IC50. Residual-concentration sevoflurane or isoflurane has a strong synergistic effect with rocuronium at clinically relevant residual concentrations. A lower rocuronium concentration resulted in a stronger synergistic effect.
Gevaert, Thomas; Neuhaus, Jochen; Vanstreels, Els; Daelemans, Dirk; Everaerts, Wouter; Der Aa, Frank Van; Timmermans, Jean-Pierre; Roskams, Tania; Steiner, Clara; Pintelon, Isabel; De Ridder, Dirk
2017-12-01
With most research on interstitial cells (IC) in the bladder being conducted on animal models, it remains unclear whether all structural and functional data on IC from animal models can be translated to the human context. This prompted us to compare the structural and immunohistochemical properties of IC in bladders from mouse, rat and human. Tissue samples were obtained from the bladder dome and subsequently processed for immunohistochemistry and electron microscopy. The ultrastructural properties of IC were compared by means of electron microscopy and IC were additionally characterized with single/double immunohistochemistry/immunofluorescence. Our results reveal a similar organization of the IC network in the upper lamina propria (ULP), the deep lamina propria (DLP) and the detrusor muscle in human, rat and mouse bladders. Furthermore, despite several similarities in IC phenotypes, we also found several obvious inter-species differences in IC, especially in the ULP. Most remarkably in this respect, ULP IC in human bladder predominantly displayed a myoid phenotype with abundant presence of contractile micro-filaments, while those in rat and mouse bladders showed a fibroblast phenotype. In conclusion, the organization of ULP IC, DLP IC and detrusor IC is comparable in human, rat and mouse bladders, although several obvious inter-species differences in IC phenotypes were found. The present data show that translating research data on IC in laboratory animals to the human setting should be carried out with caution.
Roos, Leslie E.; Knight, Erik L.; Beauchamp, Kathryn G.; Berkman, Elliot T.; Faraday, Kelsie; Hyslop, Katie; Fisher, Philip A.
2017-01-01
Identifying environmental influences on inhibitory control (IC) may help promote positive behavioral and social adjustment. Although chronic stress is known to predict lower IC, the immediate effects of acute stress are unknown. The parasympathetic nervous system (PNS) may be a mechanism of the stress-IC link, given its psychophysiological regulatory role and connections to prefrontal brain regions critical to IC. We used a focused assessment of IC (the stop-signal task) to test whether an acute social stressor (the Trier Social Stress Test) affected participants’ pre- to post-IC performance (n = 58), compared to a control manipulation (n = 31). High frequency heart-rate variability was used as an index of PNS activity in response to the manipulation. Results indicated that stress impaired IC performance, blocking the practice effects observed in control participants. We also investigated the associations between PNS activity and IC; higher resting PNS activity predicted better pre-manipulation IC, and greater PNS stressor reactivity protected against the negative effects of stress on IC. Together, these results are the first to document the immediate effects of acute stress on IC and a phenotypic marker (PNS reactivity to stressors) of susceptibility to stress-induced IC impairment. This study suggests a new way to identify situations in which individuals are likely to exhibit IC vulnerability and related consequences such as impulsivity and risk taking behavior. Targeting PNS regulation may represent a novel target for IC-focused interventions. PMID:28268165
CMOS compatible fabrication process of MEMS resonator for timing reference and sensing application
NASA Astrophysics Data System (ADS)
Huynh, Duc H.; Nguyen, Phuong D.; Nguyen, Thanh C.; Skafidas, Stan; Evans, Robin
2015-12-01
Frequency reference and timing control devices are ubiquitous in electronic applications. There is at least one resonator required for each of this device. Currently electromechanical resonators such as crystal resonator, ceramic resonator are the ultimate choices. This tendency will probably keep going for many more years. However, current market demands for small size, low power consumption, cheap and reliable products, has divulged many limitations of this type of resonators. They cannot be integrated into standard CMOS (Complement metaloxide- semiconductor) IC (Integrated Circuit) due to material and fabrication process incompatibility. Currently, these devices are off-chip and they require external circuitries to interface with the ICs. This configuration significantly increases the overall size and cost of the entire electronic system. In addition, extra external connection, especially at high frequency, will potentially create negative impacts on the performance of the entire system due to signal degradation and parasitic effects. Furthermore, due to off-chip packaging nature, these devices are quite expensive, particularly for high frequency and high quality factor devices. To address these issues, researchers have been intensively studying on an alternative for type of resonator by utilizing the new emerging MEMS (Micro-electro-mechanical systems) technology. Recent progress in this field has demonstrated a MEMS resonator with resonant frequency of 2.97 GHz and quality factor (measured in vacuum) of 42900. Despite this great achievement, this prototype is still far from being fully integrated into CMOS system due to incompatibility in fabrication process and its high series motional impedance. On the other hand, fully integrated MEMS resonator had been demonstrated but at lower frequency and quality factor. We propose a design and fabrication process for a low cost, high frequency and a high quality MEMS resonator, which can be integrated into a standard CMOS IC. This device is expected to operate in hundreds of Mhz frequency range; quality factor surpasses 10000 and series motional impedance low enough that could be matching into conventional system without enormous effort. This MEMS resonator can be used in the design of many blocks in wireless and RF (Radio Frequency) systems such as low phase noise oscillator, band pass filter, power amplifier and in many sensing application.
Epidemiology of traffic crash mortality in west of Iran in a 9 year period.
Hamzeh, Behrooz; Najafi, Farid; Karamimatin, Behzad; Ahmadijouybari, Tuoraj; Salari, Aresh; Moradinazar, Mehdi
2016-04-01
In Iran, the most common cause of injuries and the second leading cause of deaths are traffic accidents, and those problems impose a substantial financial burden on the society. This study aims to determine traffic accident mortality trends and their epidemiologic characteristics in the Kermanshah province, west of Iran. In a cross sectional study, road traffic fatality data from 2004 to 2013 were analyzed to determine the epidemiological pattern of traffic accident mortality. Trend assessment was performed to ascertain the decreasing or increasing status. Chi-square and one-way analysis of variance (ANOVA) tests, as well as Poisson regression were used to determine the significance of the data in time. Data were analyzed using Excel and statistical package of SPSS version 19. Out of 5110 people that died in traffic accidents, 4024 (78.7%) were males. The state of accidents indicated that 404 (43.8%) female pedestrians died as a result of car crashes, and 1330 (41.4%) males died because of car collisions. 1554 (31.9%) deaths happened to pedestrians and 1556 (32.1%) to vehicle drivers, and the rest belonged to vehicle passengers. Head trauma was the cause of death for as much as 3400 (69.9%) cases. Fatal crashes in which pedestrians were involved mostly occurred between the hours 13:00 to 15:00, while the time for vehicle drivers was between 16:00 to 18:00. 2882 people (59.1%) died before reaching to health care facilities. Traffic crash mortality trend for pedestrians follows a linear pattern with a gentle downward slope, but the trend shows various swings when it comes to vehicle drivers. The number of traffic crash deaths from 2004 to 2013 indicates a decreasing trend in two groups of road users: vehicle drivers and car occupants. This can be due to some interventions such as modification of traffic rules and enhancement of police control which has been implemented in recent years. Moreover, more attention should be paid to promote the optimal health care services to save the lives of the injured from traffic accidents.
Evaluation of bisindole as potent β-glucuronidase inhibitors: synthesis and in silico based studies.
Khan, Khalid Mohammed; Rahim, Fazal; Wadood, Abdul; Taha, Muhammad; Khan, Momin; Naureen, Shagufta; Ambreen, Nida; Hussain, Shafqat; Perveen, Shahnaz; Choudhary, Mohammad Iqbal
2014-04-01
Bisindole analogs 1-17 were synthesized and evaluated for their in vitro β-glucuronidase inhibitory potential. Out of seventeen compounds, the analog 1 (IC50=1.62±0.04 μM), 6 (IC50=1.86±0.05 μM), 10 (IC50=2.80±0.29 μM), 9 (IC50=3.10±0.28 μM), 14 (IC50=4.30±0.08 μM), 2 (IC50=18.40±0.09 μM), 19 (IC50=19.90±1.05 μM), 4 (IC50=20.90±0.62 μM), 7 (IC50=21.50±0.77 μM), and 3 (IC50=22.30±0.02 μM) showed superior β-glucuronidase inhibitory activity than the standard (d-saccharic acid 1,4-lactone, IC50=48.40±1.25 μM). In addition, molecular docking studies were performed to investigate the binding interactions of bisindole derivatives with the enzyme. This study has identified a new class of potent β-glucouronidase inhibitors. Copyright © 2014 Elsevier Ltd. All rights reserved.
High-power, format-flexible, 885-nm vertical-cavity surface-emitting laser arrays
NASA Astrophysics Data System (ADS)
Wang, Chad; Talantov, Fedor; Garrett, Henry; Berdin, Glen; Cardellino, Terri; Millenheft, David; Geske, Jonathan
2013-03-01
High-power, format flexible, 885 nm vertical-cavity surface-emitting laser (VCSEL) arrays have been developed for solid-state pumping and illumination applications. In this approach, a common VCSEL size format was designed to enable tiling into flexible formats and operating configurations. The fabrication of a common chip size on ceramic submount enables low-cost volume manufacturing of high-power VCSEL arrays. This base VCSEL chip was designed to be 5x3.33 mm2, and produced up to 50 Watts of peak continuous wave (CW) power. To scale to higher powers, multiple chips can be tiled into a combination of series or parallel configurations tailored to the application driver conditions. In actively cooled CW operation, the VCSEL array chips were packaged onto a single water channel cooler, and we have demonstrated 0.5x1, 1x1, and 1x3 cm2 formats, producing 150, 250, and 500 Watts of peak power, respectively, in under 130 A operating current. In QCW operation, the 1x3 cm2 VCSEL module, which contains 18 VCSEL array chips packaged on a single water cooler, produced over 1.3 kW of peak power. In passively cooled packages, multiple chip configurations have been developed for illumination applications, producing over 300 Watts of peak power in QCW operating conditions. These VCSEL chips use a substrate-removed structure to allow for efficient thermal heatsinking to enable high-power operation. This scalable, format flexible VCSEL architecture can be applied to wavelengths ranging from 800 to 1100 nm, and can be used to tailor emission spectral widths and build high-power hyperspectral sources.
Souliotis, Kyriakos; Kani, Chara; Papageorgiou, Manto; Lionis, Dimitrios; Gourgoulianis, Konstantinos
2016-01-01
Chronic Obstructive Pulmonary Disease (COPD) is one of the top leading causes of death and disability, and its management is focused on reducing risk factors, relieving symptoms, and preventing exacerbations. The study aim was to describe COPD prescribing patterns in Greece by using existing health administrative data for outpatients. This is a retrospective cross-sectional study based on prescriptions collected by the largest social insurance fund, during the first and last trimester of 2012. Selection criteria were the prescription of specific active substances and a COPD diagnosis. Extracted information included active substance, strength, pharmaceutical form and number of packages prescribed, diagnosis, time of dispensing, as well as insurees' age, gender, percentage of co-payment and social security unique number. Statistical analysis included descriptive statistics and logistic regression. 174,357 patients received medicines for COPD during the study period. Patients were almost equally distributed between male and female, and age above 55 years was strongly correlated with COPD. Most patients received a long-acting beta agonist plus inhaled corticosteroid combination (LABA +ICS), followed by long-acting muscarinic agonist (LAMA). 63% patients belonging in the 35-54 age received LABA+ICS. LAMA was prescribed more frequently among males and was strongly correlated with COPD. The study provides big data analysis of Greek COPD prescribing patterns. It highlights the need for appropriate COPD classification in primary care illustrating the role of electronic prescribing in ensuring appropriate prescribing. Moreover, it indicates possible gender differences in treatment response or disease severity, and the impact of statutory co-payments on prescribing.
Monje-Agudo, Patricia; Borrego-Izquierdo, Yolanda; Robustillo-Cortés, Ma de Las Aguas; Jiménez-Galán, Rocio; Almeida-González, Carmen V; Morillo-Verdugo, Ramón A
2015-05-01
To design and to validate a questionnaire to assess satisfaction with pharmaceutical care (PC) received at the hospital pharmacy. Multicentric study in five andalusian hospital in January 2013. A bibliography search was performed in PUBMED; MESH term; pharmaceutical services, patients satisfaction and questionnaire. Next, the questionnaire was produced by Delphi methodology with ten items and with the following variables; demographics, socials, pharrmacologicals and clinics which the patient was asked for the consequences of the PC in his treatment and illness and for the acceptance with the received service. The patient could answer between one= very insufficient and five= excellent. Before the validation phase questionnaire, a pilot phase was carried out. Descriptive analysis, Cronbach's alpha coefficient and intraclass correlation coefficient (ICC) were performed in both phases. Data analysis was conducted using the SPSS statistical software package release 20.0. In the pilot phase were included 21 questionnaires and 154 of them in validation phase (response index of 100%). In the last phase, 62% (N=96) of patients were men. More than 50% of patients answered "excelent" in all items of questionnaire in both phases. The Cronbach's alpha coefficient and ICC were 0.921 and 0.915 (95%IC: 0.847-0.961) and 0.916 and 0,910 (95%IC: 0.886-0.931) in pilot and validation phases, respectively. A high reliability instrument was designed and validated to evaluate the patient satisfaction with PC received at hospital pharmacy. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Leicht, Anthony; Crowther, Robert; Golledge, Jonathan
2015-05-18
This study examined the impact of regular supervised exercise on body fat, assessed via anthropometry, and eating patterns of peripheral arterial disease patients with intermittent claudication (IC). Body fat, eating patterns and walking ability were assessed in 11 healthy adults (Control) and age- and mass-matched IC patients undertaking usual care (n = 10; IC-Con) or supervised exercise (12-months; n = 10; IC-Ex). At entry, all groups exhibited similar body fat and eating patterns. Maximal walking ability was greatest for Control participants and similar for IC-Ex and IC-Con patients. Supervised exercise resulted in significantly greater improvements in maximal walking ability (IC-Ex 148%-170% vs. IC-Con 29%-52%) and smaller increases in body fat (IC-Ex -2.1%-1.4% vs. IC-Con 8.4%-10%). IC-Con patients exhibited significantly greater increases in body fat compared with Control at follow-up (8.4%-10% vs. -0.6%-1.4%). Eating patterns were similar for all groups at follow-up. The current study demonstrated that regular, supervised exercise significantly improved maximal walking ability and minimised increase in body fat amongst IC patients without changes in eating patterns. The study supports the use of supervised exercise to minimize cardiovascular risk amongst IC patients. Further studies are needed to examine the additional value of other lifestyle interventions such as diet modification.
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-12-28
To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system.
Duzel, Antonija; Vlainic, Josipa; Antunovic, Marko; Malekinusic, Dominik; Vrdoljak, Borna; Samara, Mariam; Gojkovic, Slaven; Krezic, Ivan; Vidovic, Tinka; Bilic, Zdenko; Knezevic, Mario; Sever, Marko; Lojo, Nermin; Kokot, Antonio; Kolovrat, Marijan; Drmic, Domagoj; Vukojevic, Jaksa; Kralj, Tamara; Kasnik, Katarina; Siroglavic, Marko; Seiwerth, Sven; Sikiric, Predrag
2017-01-01
AIM To provide new insights in treatment of colitis and ischemia and reperfusion in rats using stable gastric pentadecapeptide BPC 157. METHODS Medication [BPC 157, L-NAME, L-arginine (alone/combined), saline] was bath at the blood deprived colon segment. During reperfusion, medication was BPC 157 or saline. We recorded (USB microscope camera) vessel presentation through next 15 min of ischemic colitis (IC-rats) or reperfusion (removed ligations) (IC + RL-rats); oxidative stress as MDA (increased (IC- and IC + RL-rats)) and NO levels (decreased (IC-rats); increased (IC + RL-rats)) in colon tissue. IC + OB-rats [IC-rats had additional colon obstruction (OB)] for 3 d (IC + OB-rats), then received BPC 157 bath. RESULTS Commonly, in colon segment (25 mm, 2 ligations on left colic artery and vein, 3 arcade vessels within ligated segment), in IC-, IC + RL-, IC + OB-rats, BPC 157 (10 μg/kg) bath (1 mL/rat) increased vessel presentation, inside/outside arcade interconnections quickly reappeared, mucosal folds were preserved and the pale areas were small and markedly reduced. BPC 157 counteracted worsening effects induced by L-NAME (5 mg) and L-arginine (100 mg). MDA- and NO-levels were normal in BPC 157 treated IC-rats and IC + RL-rats. In addition, on day 10, BPC 157-treated IC + OB-rats presented almost completely spared mucosa with very small pale areas and no gross mucosal defects; the treated colon segment was of normal diameter, and only small adhesions were present. CONCLUSION BPC 157 is a fundamental treatment that quickly restores blood supply to the ischemically injured area and rapidly activates collaterals. This effect involves the NO system. PMID:29358856
Hashimoto, K.; Tsujimura, T.; Moriyama, Y.; Yamatodani, A.; Kimura, M.; Tohya, K.; Morimoto, M.; Kitayama, H.; Kanakura, Y.; Kitamura, Y.
1996-01-01
Two mutations of c-kit receptor tyrosine kinase (KIT), valine-559 to glycine (G559) and aspartic acid-814 to valine (V814), resulted in its constitutive activation. To examine the transforming and differentiation-inducing potential of the mutant KIT, we used the murine interleukin-3-dependent IC-2 mast cell line as a transfectant. The IC-2 cells contained few basophilic granules and did not express KIT on the surface. The KITG559 or KITV814 gene was introduced into IC-2 cells using a retroviral vector. KITG559 and KITV814 expressed in IC-2 cells were constitutively phosphorylated on tyrosine and demonstrated kinase activity in the absence of stem cell factor, which is a ligand for KIT. IC-2 cells expressing either KITG559 or KITV814 (IC-2G559 or IC-2V814 cells) showed factor-independent growth in suspension culture and produced tumors in nude athymic mice. In addition, IC-2G559 and IC-2V814 cells showed a more mature phenotype compared with the phenotype of the original IC-2 cells, especially after transplantation into nude mice. The number of basophilic granules and the content of histamine increased remarkably. KITG559 and KITV814 also influenced the transcriptional phenotype of mouse mast cell proteases (MMCP) in IC-2 cells. The expression of MMCP-2, MMCP-4, and MMCP-6 was much greater in IC-2G559 and IC-2V814 cells than in the original IC-2 cells. The results indicated that constitutively activated KIT had not only oncogenic activity but also differentiation-inducing activity in mast cells. Images Figure 1 Figure 4 Figure 5 Figure 6 PMID:8546206
Wells, Karen E.; Peterson, Edward L.; Ahmedani, Brian K.; Severson, Richard K.; Gleason-Comstock, Julie; Williams, L. Keoki
2012-01-01
Background Safety concerns surround the use of long-acting beta agonists (LABA) for the treatment of asthma, even in combination with inhaled corticosteroids (ICS) and particularly in high-risk subgroups. Objective To estimate the effect ICS therapy and fixed-dose ICS/LABA combination therapy on severe asthma exacerbations in a racially diverse population. Methods Inhaled corticosteroid and ICS/LABA exposure was estimated from pharmacy data for patients with asthma age 12 to 56 years who were members of a large health maintenance organization. Inhaled corticosteroid and ICS/LABA use was estimated for each day of follow-up to create a moving window of exposure. Proportional hazard models were used to assess the relationship between ICS and ICS/LABA combination therapy and severe asthma exacerbations (i.e., use of oral corticosteroids, asthma-related emergency department visit, or asthma-related hospitalization). Results Among the 1,828 patients who met the inclusion criteria, 37% were African American, 46% were treated with ICS therapy alone, and 54% were treated with an ICS/LABA combination. Models assessing the risk of severe asthma exacerbations among individuals using ICS treatment alone and ICS/LABA combination therapy suggested that the overall protective effect was as good or better for ICS/LABA combination therapy when compared with ICS treatment alone (hazard ratio [HR]=0.65 vs. HR=0.72, respectively). Analyses in several subgroups, including African American patients, showed a similar statistically significant protective association for combination therapy. Conclusion Treatment with ICS/LABA fixed combination therapy appeared to perform as well or better than ICS alone in reducing severe asthma exacerbations; this included multiple high-risk subgroups. PMID:22281166
Taha, Muhammad; Ismail, Nor Hadiani; Imran, Syahrul; Rashwan, Hesham; Jamil, Waqas; Ali, Sajjad; Kashif, Syed Muhammad; Rahim, Fazal; Salar, Uzma; Khan, Khalid Mohammed
2016-04-01
6-Chloro-2-Aryl-1H-imidazo[4,5-b]pyridine derivatives 1-26 were synthesized and characterized by various spectroscopic techniques. All these derivatives were evaluated for their antiglycation, antioxidant and β-glucuronidase potential followed their docking studies. In antiglycation assay, compound 2 (IC50=240.10±2.50μM) and 4 (IC50=240.30±2.90μM) was found to be most active compound of this series, while compounds 3 (IC50=260.10±2.50μM), 6 (IC50=290.60±3.60μM), 13 (IC50=288.20±3.00μM) and 26 (IC50=292.10±3.20μM) also showed better activities than the standard rutin (IC50=294.50±1.50μM). In antioxidant assay, compound 1 (IC50=69.45±0.25μM), 2 (IC50=58.10±2.50μM), 3 (IC50=74.25±1.10μM), and 4 (IC50=72.50±3.30μM) showed good activities. In β-glucuronidase activity, compounds 3 (IC50=29.25±0.50μM), compound 1 (IC50=30.10±0.60μM) and compound 4 (IC50=46.10±1.10μM) showed a significant activity as compared to than standard D-Saccharic acid 1,4-lactonec (IC50=48.50±1.25μM) and their interaction with the enzyme was confirm by docking studies. Copyright © 2016 Elsevier Inc. All rights reserved.
RADIOLOGICAL SURVEY STATION DEVELOPMENT FOR THE PIT DISASSEMBLY AND CONVERSION PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalmaso, M.; Gibbs, K.; Gregory, D.
2011-05-22
The Savannah River National Laboratory (SRNL) has developed prototype equipment to demonstrate remote surveying of Inner and Outer DOE Standard 3013 containers for fixed and transferable contamination in accordance with DOE Standard 3013 and 10 CFR 835 Appendix B. When fully developed the equipment will be part of a larger suite of equipment used to package material in accordance with DOE Standard 3013 at the Pit Disassembly and Conversion Project slated for installation at the Savannah River Site. The prototype system consists of a small six-axis industrial robot with an end effector consisting of a force sensor, vacuum gripper andmore » a three fingered pneumatic gripper. The work cell also contains two alpha survey instruments, swipes, swipe dispenser, and other ancillary equipment. An external controller interfaces with the robot controller, survey instruments and other ancillary equipment to control the overall process. SRNL is developing automated equipment for the Pit Disassembly and Conversion (PDC) Project that is slated for the Savannah River Site (SRS). The equipment being developed is automated packaging equipment for packaging plutonium bearing materials in accordance with DOE-STD-3013-2004. The subject of this paper is the development of a prototype Radiological Survey Station (RSS). Other automated equipment being developed for the PDC includes the Bagless transfer System, Outer Can Welder, Gantry Robot System (GRS) and Leak Test Station. The purpose of the RSS is to perform a frisk and swipe of the DOE Standard 3013 Container (either inner can or outer can) to check for fixed and transferable contamination. This is required to verify that the contamination levels are within the limits specified in DOE-STD-3013-2004 and 10 CFR 835, Appendix D. The surface contamination limit for the 3013 Outer Can (OC) is 500 dpm/100 cm2 (total) and 20 dpm/100 cm2 (transferable). This paper will concentrate on the RSS developments for the 3013 OC but the system for the 3013 Inner Can (IC) is nearly identical.« less
Thick resist for MEMS processing
NASA Astrophysics Data System (ADS)
Brown, Joe; Hamel, Clifford
2001-11-01
The need for technical innovation is always present in today's economy. Microfabrication methods have evolved in support of the demand for smaller and faster integrated circuits with price performance improvements always in the scope of the manufacturing design engineer. The dispersion of processing technology spans well beyond IC fabrication today with batch fabrication and wafer scale processing lending advantages to MEMES applications from biotechnology to consumer electronics from oil exploration to aerospace. Today the demand for innovative processing techniques that enable technology is apparent where only a few years ago appeared too costly or not reliable. In high volume applications where yield and cost improvements are measured in fractions of a percent it is imperative to have process technologies that produce consistent results. Only a few years ago thick resist coatings were limited to thickness less than 20 microns. Factors such as uniformity, edge bead and multiple coatings made high volume production impossible. New developments in photoresist formulation combined with advanced coating equipment techniques that closely controls process parameters have enable thick photoresist coatings of 70 microns with acceptable uniformity and edge bead in one pass. Packaging of microelectronic and micromechanical devices is often a significant cost factor and a reliability issue for high volume low cost production. Technologies such as flip- chip assembly provide a solution for cost and reliability improvements over wire bond techniques. The processing for such technology demands dimensional control and presents a significant cost savings if it were compatible with mainstream technologies. Thick photoresist layers, with good sidewall control would allow wafer-bumping technologies to penetrate the barriers to yield and production where costs for technology are the overriding issue. Single pass processing is paramount to the manufacturability of packaging technology. Uniformity and edge bead control defined the success of process implementation. Today advanced packaging solutions are created with thick photoresist coatings. The techniques and results will be presented.
New generation QuIC assays for prion seeding activity.
Orrù, Christina D; Wilham, Jason M; Vascellari, Sarah; Hughson, Andrew G; Caughey, Byron
2012-01-01
The ability of abnormal TSE-associated forms of PrP to seed the formation of amyloid fibrils from recombinant PrP(Sen) has served as the basis for several relatively rapid and highly sensitive tests for prion diseases. These tests include rPrP-PMCA (rPMCA), standard quaking-induced conversion (S-QuIC), amyloid seeding assay (ASA), real-time QuIC (RT-QuIC) and enhanced QuIC (eQuIC). Here, we summarize recent improvements in the RT-QuIC-based assays that enhance the practicality, sensitivity and quantitative attributes of assays QuIC and promote the detection of prion seeding activity in dilute, inhibitor-laden fluids such as blood plasma.
2012-01-01
Background Allocating national resources to regions based on need is a key policy issue in most health systems. Many systems utilise proxy measures of need as the basis for allocation formulae. Increasingly these are underpinned by complex statistical methods to separate need from supplier induced utilisation. Assessment of need is then used to allocate existing global budgets to geographic areas. Many low and middle income countries are beginning to use formula methods for funding however these attempts are often hampered by a lack of information on utilisation, relative needs and whether the budgets allocated bear any relationship to cost. An alternative is to develop bottom-up estimates of the cost of providing for local need. This method is viable where public funding is focused on a relatively small number of targeted services. We describe a bottom-up approach to developing a formula for the allocation of resources. The method is illustrated in the context of the state minimum service package mandated to be provided by the Indonesian public health system. Methods A standardised costing methodology was developed that is sensitive to the main expected drivers of local cost variation including demographic structure, epidemiology and location. Essential package costing is often undertaken at a country level. It is less usual to utilise the methods across different parts of a country in a way that takes account of variation in population needs and location. Costing was based on best clinical practice in Indonesia and province specific data on distribution and costs of facilities. The resulting model was used to estimate essential package costs in a representative district in each province of the country. Findings Substantial differences in the costs of providing basic services ranging from USD 15 in urban Yogyakarta to USD 48 in sparsely populated North Maluku. These costs are driven largely by the structure of the population, particularly numbers of births, infants and children and also key diseases with high cost/prevalence and variation, most notably the level of malnutrition. The approach to resource allocation was implemented using existing data sources and permitted the rapid construction of a needs based formula that is highly specific to the package mandated across the country. Refinement could focus more on resources required to finance demand side costs and expansion of the service package to include priority non-communicable services. PMID:22931536
Ensor, Tim; Firdaus, Hafidz; Dunlop, David; Manu, Alex; Mukti, Ali Ghufron; Ayu Puspandari, Diah; von Roenne, Franz; Indradjaya, Stephanus; Suseno, Untung; Vaughan, Patrick
2012-08-29
Allocating national resources to regions based on need is a key policy issue in most health systems. Many systems utilise proxy measures of need as the basis for allocation formulae. Increasingly these are underpinned by complex statistical methods to separate need from supplier induced utilisation. Assessment of need is then used to allocate existing global budgets to geographic areas. Many low and middle income countries are beginning to use formula methods for funding however these attempts are often hampered by a lack of information on utilisation, relative needs and whether the budgets allocated bear any relationship to cost. An alternative is to develop bottom-up estimates of the cost of providing for local need. This method is viable where public funding is focused on a relatively small number of targeted services. We describe a bottom-up approach to developing a formula for the allocation of resources. The method is illustrated in the context of the state minimum service package mandated to be provided by the Indonesian public health system. A standardised costing methodology was developed that is sensitive to the main expected drivers of local cost variation including demographic structure, epidemiology and location. Essential package costing is often undertaken at a country level. It is less usual to utilise the methods across different parts of a country in a way that takes account of variation in population needs and location. Costing was based on best clinical practice in Indonesia and province specific data on distribution and costs of facilities. The resulting model was used to estimate essential package costs in a representative district in each province of the country. Substantial differences in the costs of providing basic services ranging from USD 15 in urban Yogyakarta to USD 48 in sparsely populated North Maluku. These costs are driven largely by the structure of the population, particularly numbers of births, infants and children and also key diseases with high cost/prevalence and variation, most notably the level of malnutrition. The approach to resource allocation was implemented using existing data sources and permitted the rapid construction of a needs based formula that is highly specific to the package mandated across the country. Refinement could focus more on resources required to finance demand side costs and expansion of the service package to include priority non-communicable services.
Apparatus and method for defect testing of integrated circuits
Cole, Jr., Edward I.; Soden, Jerry M.
2000-01-01
An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.
Silicon photonics devices for metro applications
NASA Astrophysics Data System (ADS)
Fukuda, H.; Kikuchi, K.; Jizodo, M.; Kawamura, Y.; Takeda, K.; Honda, K.
2017-01-01
Digital coherent technology is considered an attractive way of realizing both high-speed metro links and long distance transmissions. In metro areas, there is a strong demand for a smaller, faster transceiver module. This demand is mainly driven by the rapidly increasing data center interconnection traffic, where transmission capacity per faceplane is a key feature. Therefore, optical integration technology is desired. Since compensation in digital coherent technology is performed in the electrical or digital domain, users can deal with those optics performances that are not compensated for digitally. This means using a new material that cannot provide perfect characteristics but that is suitable for miniaturization and integration is possible. Silicon photonics (SiPh) is considered an attractive technology that would enable the significant miniaturization of optical circuits and be capable of optical integration with high manufacturability. While SiPh-based devices have begun to be deployed for very short or short reach links on the basis of direct detection technology, their digital coherent applications have recently been investigated in view of their integration capability. This paper describes recent progress on SiPh-based integrated optical devices for high-speed digital coherent transceivers targeting metro links. An optical modulator and receiver with related circuits have been integrated into a single SiPh chip. TEC-free operation under non-hermetic conditions and the direct attachment of optical fibers have both been realized. Very thin and small packaging with sufficient performance has been demonstrated by using the SiPh chip co-packaged with high-speed ICs.
Schminke, G; Seubert, A
2000-02-01
An established method for the determination of the disinfection by-product bromate is ion chromatography (IC). This paper presents a comparison of three IC methods based on either conductivity detection (IC-CD), a post-column-reaction (IC-PCR-VIS) or the on-line-coupling with inductively coupled plasma mass spectrometry (IC-ICP-MS). Main characteristics of the methods such as method detection limits (MDL), time of analysis and sample pretreatment are compared and applicability for routine analysis is critically discussed. The most sensitive and rugged method is IC-ICP-MS, followed by IC-PCR-VIS. The photometric detection is subject to a minor interference in real world samples, presumably caused by carbonate. The lowest sensitivity is shown by the IC-CD method as slowest method compared, which, in addition, requires a sample pretreatment. The highest amount of information is delivered by IC-PCR-VIS, which allows the simultaneous determination of the seven standard anions and bromate.
Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne; Kedzior, Karina Karolina
2018-01-01
Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the intercultural experience and the current global discourse. Longitudinal studies with representative samples are required to assess how IC definitions change over time.
Synthesis of novel amides based on acridone scaffold with interesting antineoplastic activity.
Mahajan, Anand A; Rane, Rajesh A; Amritkar, Anish A; Naphade, Shital S; Miniyar, Pankaj B; Bangalore, Pavan Kumar; Karpoormath, Rajshekhar
2015-01-01
In search of novel cytotoxic agents based on acridone scaffold, twenty five derivatives of acridone-2- carboxamide were synthesized and evaluated against a panel of eleven cancer cell lines by using MTT assay. Amides, A5 and A8 (IC50 = 0.3 µM) exhibited good cytotoxicity against MCF7. Compound A22 (IC50 = 4.3 µM) was found to be selectively cytotoxic against cancer cell line MCF7 and KB403. Particularly, promising cytotoxic activities were shown by amides A6 (IC50 = 0.7 µM), A16 (IC50 = 6.3 µM), A8 (IC50 = 0.9 µM ), A21 (IC50 = 1.3 µM), A5 (IC50 = 2.9 µM), A8 (IC50 = 2.8 µM), A14 (IC50 = 0.8 µM), A9 (IC50 = 0.8 µM) and A8 (IC50 = 0.4 µM) against cell lines; PA1, WRL68, CaCO2, TK-10, K-562, PC-3, HOP-92, ECV-304 and UACC-257, respectively. The favorable cytotoxic profile and non-toxicity towards normal human cells displayed by the derivative revealed their potential for further anticancer drug developments.
An integrated conceptual framework for evaluating and improving 'understanding' in informed consent.
Bossert, Sabine; Strech, Daniel
2017-10-17
The development of understandable informed consent (IC) documents has proven to be one of the most important challenges in research with humans as well as in healthcare settings. Therefore, evaluating and improving understanding has been of increasing interest for empirical research on IC. However, several conceptual and practical challenges for the development of understandable IC documents remain unresolved. In this paper, we will outline and systematize some of these challenges. On the basis of our own experiences in empirical user testing of IC documents as well as the relevant literature on understanding in IC, we propose an integrated conceptual model for the development of understandable IC documents. The proposed conceptual model integrates different methods for the participatory improvement of written information, including IC, as well as quantitative methods for measuring understanding in IC. In most IC processes, understandable written information is an important prerequisite for valid IC. To improve the quality of IC documents, a conceptual model for participatory procedures of testing, revising, and retesting can be applied. However, the model presented in this paper needs further theoretical and empirical elaboration and clarification of several conceptual and practical challenges.
Khan, K M; Shah, Zarbad; Ahmad, V U; Ambreen, N; Khan, M; Taha, M; Rahim, F; Noreen, S; Perveen, S; Choudhary, M I; Voelter, W
2012-02-15
6-Nitrobenzimidazole derivatives (1-30) synthesized and their phosphodiesterase inhibitory activities determined. Out of thirty tested compounds, ten showed a varying degrees of phosphodiesterase inhibition with IC(50) values between 1.5±0.043 and 294.0±16.7 μM. Compounds 30 (IC(50)=1.5±0.043 μM), 1 (IC(50)=2.4±0.049 μM), 11 (IC(50)=5.7±0.113 μM), 13 (IC(50)=6.4±0.148 μM), 14 (IC(50)=10.5±0.51 μM), 9 (IC(50)=11.49±0.08 μM), 3 (IC(50)=63.1±1.48 μM), 10 (IC(50)=120.0±4.47 μM), and 6 (IC(50)=153.2±5.6 μM) showed excellent phosphodiesterase inhibitory activity, much superior to the standard EDTA (IC(50)=274±0.007 μM), and thus are potential molecules for the development of a new class of phosphodiesterase inhibitors. A structure-activity relationship is evaluated. All compounds are characterized by spectroscopic parameters. Copyright © 2011 Elsevier Ltd. All rights reserved.
Association between lower air pressure and the onset of ischemic colitis: a case-control study.
Kimura, Takefumi; Shinji, Akihiro; Tanaka, Naoki; Koinuma, Masayoshi; Yamaura, Maki; Nagaya, Tadanobu; Joshita, Satoru; Komatsu, Michiharu; Umemura, Takeji; Horiuchi, Akira; Wada, Shuichi; Tanaka, Eiji
2017-09-01
Ischemic colitis (IC) often affects the elderly. Proarteriosclerotic factors, such as hypertension and smoking, and cardiovascular disease are considered major contributors to IC. Although a possible link between certain cerebrocardiovascular disorders and meteorological phenomena has been reported, the relationship between IC onset and weather changes remains uninvestigated. This study examined whether specific meteorological factors were associated with the occurrence of IC. We retrospectively enrolled 303 patients who had been diagnosed with IC between January 2003 and June 2010 at Suwa Red Cross Hospital in Nagano Prefecture, Japan. The meteorological data of the days on which IC patients visited the hospital (IC+ days) were compared with those of the days on which IC patients did not (IC- days). Univariate analysis indicated that IC+ days had significantly lower air pressure (P<0.001), depressed air pressure from the previous day (P<0.001), and fewer daylight hours (P<0.001), as well as higher air temperature (P=0.017), air humidity (P=0.004), wind velocity (P<0.001), and rainfall (P=0.012) compared with IC- days. Multivariate logistic regression analysis of the meteorological data showed that air pressure (odds ratio: 0.935, P<0.001) and change in air pressure from the previous day (odds ratio: 0.934, P<0.001) were related to onset of IC. Lower air pressure and decrease in air pressure from the previous day are possible novel factors associated with the development of IC.
Characterization and Exploitation of CRISPR Loci in Bifidobacterium longum
Hidalgo-Cantabrana, Claudio; Crawley, Alexandra B.; Sanchez, Borja; Barrangou, Rodolphe
2017-01-01
Diverse CRISPR-Cas systems provide adaptive immunity in many bacteria and most archaea, via a DNA-encoded, RNA-mediated, nucleic-acid targeting mechanism. Over time, CRISPR loci expand via iterative uptake of invasive DNA sequences into the CRISPR array during the adaptation process. These genetic vaccination cards thus provide insights into the exposure of strains to phages and plasmids in space and time, revealing the historical predatory exposure of a strain. These genetic loci thus constitute a unique basis for genotyping of strains, with potential of resolution at the strain-level. Here, we investigate the occurrence and diversity of CRISPR-Cas systems in the genomes of various Bifidobacterium longum strains across three sub-species. Specifically, we analyzed the genomic content of 66 genomes belonging to B. longum subsp. longum, B. longum subsp. infantis and B. longum subsp. suis, and identified 25 strains that carry 29 total CRISPR-Cas systems. We identify various Type I and Type II CRISPR-Cas systems that are widespread in this species, notably I-C, I-E, and II-C. Noteworthy, Type I-C systems showed extended CRISPR arrays, with extensive spacer diversity. We show how these hypervariable loci can be used to gain insights into strain origin, evolution and phylogeny, and can provide discriminatory sequences to distinguish even clonal isolates. By investigating CRISPR spacer sequences, we reveal their origin and implicate phages and prophages as drivers of CRISPR immunity expansion in this species, with redundant targeting of select prophages. Analysis of CRISPR spacer origin also revealed novel PAM sequences. Our results suggest that CRISPR-Cas immune systems are instrumental in mounting diversified viral resistance in B. longum, and show that these sequences are useful for typing across three subspecies. PMID:29033911
Characterization and Exploitation of CRISPR Loci in Bifidobacterium longum.
Hidalgo-Cantabrana, Claudio; Crawley, Alexandra B; Sanchez, Borja; Barrangou, Rodolphe
2017-01-01
Diverse CRISPR-Cas systems provide adaptive immunity in many bacteria and most archaea, via a DNA-encoded, RNA-mediated, nucleic-acid targeting mechanism. Over time, CRISPR loci expand via iterative uptake of invasive DNA sequences into the CRISPR array during the adaptation process. These genetic vaccination cards thus provide insights into the exposure of strains to phages and plasmids in space and time, revealing the historical predatory exposure of a strain. These genetic loci thus constitute a unique basis for genotyping of strains, with potential of resolution at the strain-level. Here, we investigate the occurrence and diversity of CRISPR-Cas systems in the genomes of various Bifidobacterium longum strains across three sub-species. Specifically, we analyzed the genomic content of 66 genomes belonging to B. longum subsp. longum, B. longum subsp. infantis and B. longum subsp. suis , and identified 25 strains that carry 29 total CRISPR-Cas systems. We identify various Type I and Type II CRISPR-Cas systems that are widespread in this species, notably I-C, I-E, and II-C. Noteworthy, Type I-C systems showed extended CRISPR arrays, with extensive spacer diversity. We show how these hypervariable loci can be used to gain insights into strain origin, evolution and phylogeny, and can provide discriminatory sequences to distinguish even clonal isolates. By investigating CRISPR spacer sequences, we reveal their origin and implicate phages and prophages as drivers of CRISPR immunity expansion in this species, with redundant targeting of select prophages. Analysis of CRISPR spacer origin also revealed novel PAM sequences. Our results suggest that CRISPR-Cas immune systems are instrumental in mounting diversified viral resistance in B. longum , and show that these sequences are useful for typing across three subspecies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graur, Or; Bianco, Federica B.; Huang, Shan
Most types of supernovae (SNe) have yet to be connected with their progenitor stellar systems. Here, we reanalyze the 10-year SN sample collected during 1998–2008 by the Lick Observatory Supernova Search (LOSS) in order to constrain the progenitors of SNe Ia and stripped-envelope SNe (SE SNe, i.e., SNe IIb, Ib, Ic, and broad-lined Ic). We matched the LOSS galaxy sample with spectroscopy from the Sloan Digital Sky Survey and measured SN rates as a function of galaxy stellar mass, specific star formation rate, and oxygen abundance (metallicity). We find significant correlations between the SN rates and all three galaxy properties.more » The SN Ia correlations are consistent with other measurements, as well as with our previous explanation of these measurements in the form of a combination of the SN Ia delay-time distribution and the correlation between galaxy mass and age. The ratio between the SE SN and SN II rates declines significantly in low-mass galaxies. This rules out single stars as SE SN progenitors, and is consistent with predictions from binary-system progenitor models. Using well-known galaxy scaling relations, any correlation between the rates and one of the galaxy properties examined here can be expressed as a correlation with the other two. These redundant correlations preclude us from establishing causality—that is, from ascertaining which of the galaxy properties (or their combination) is the physical driver for the difference between the SE SN and SN II rates. We outline several methods that have the potential to overcome this problem in future works.« less
NASA Astrophysics Data System (ADS)
Graur, Or; Bianco, Federica B.; Huang, Shan; Modjaz, Maryam; Shivvers, Isaac; Filippenko, Alexei V.; Li, Weidong; Eldridge, J. J.
2017-03-01
Most types of supernovae (SNe) have yet to be connected with their progenitor stellar systems. Here, we reanalyze the 10-year SN sample collected during 1998-2008 by the Lick Observatory Supernova Search (LOSS) in order to constrain the progenitors of SNe Ia and stripped-envelope SNe (SE SNe, I.e., SNe IIb, Ib, Ic, and broad-lined Ic). We matched the LOSS galaxy sample with spectroscopy from the Sloan Digital Sky Survey and measured SN rates as a function of galaxy stellar mass, specific star formation rate, and oxygen abundance (metallicity). We find significant correlations between the SN rates and all three galaxy properties. The SN Ia correlations are consistent with other measurements, as well as with our previous explanation of these measurements in the form of a combination of the SN Ia delay-time distribution and the correlation between galaxy mass and age. The ratio between the SE SN and SN II rates declines significantly in low-mass galaxies. This rules out single stars as SE SN progenitors, and is consistent with predictions from binary-system progenitor models. Using well-known galaxy scaling relations, any correlation between the rates and one of the galaxy properties examined here can be expressed as a correlation with the other two. These redundant correlations preclude us from establishing causality—that is, from ascertaining which of the galaxy properties (or their combination) is the physical driver for the difference between the SE SN and SN II rates. We outline several methods that have the potential to overcome this problem in future works.
VizieR Online Data Catalog: Lick Observatory Supernova Search (LOSS) revisited (Graur+, 2017)
NASA Astrophysics Data System (ADS)
Graur, O.; Bianco, F. B.; Huang, S.; Modjaz, M.; Shivvers, I.; Filippenko, A. V.; Li, W.; Eldridge, J. J.
2017-10-01
Most types of supernovae (SNe) have yet to be connected with their progenitor stellar systems. Here, we reanalyze the 10-year SN sample collected during 1998-2008 by the Lick Observatory Supernova Search (LOSS; see Leaman+, 2011, J/MNRAS/412/1419) in order to constrain the progenitors of SNe Ia and stripped-envelope SNe (SE SNe, i.e., SNe IIb, Ib, Ic, and broad-lined Ic). We matched the LOSS galaxy sample with spectroscopy from the Sloan Digital Sky Survey (SDSS) and measured SN rates as a function of galaxy stellar mass, specific star formation rate, and oxygen abundance (metallicity). We find significant correlations between the SN rates and all three galaxy properties. The SN Ia correlations are consistent with other measurements, as well as with our previous explanation of these measurements in the form of a combination of the SN Ia delay-time distribution and the correlation between galaxy mass and age. The ratio between the SE SN and SN II rates declines significantly in low-mass galaxies. This rules out single stars as SE SN progenitors, and is consistent with predictions from binary-system progenitor models. Using well-known galaxy scaling relations, any correlation between the rates and one of the galaxy properties examined here can be expressed as a correlation with the other two. These redundant correlations preclude us from establishing causality-that is, from ascertaining which of the galaxy properties (or their combination) is the physical driver for the difference between the SE SN and SN II rates. We outline several methods that have the potential to overcome this problem in future works. (7 data files).
Schwab, C L; Bellone, S; English, D P; Roque, D M; Lopez, S; Cocco, E; Nicoletti, R; Bortolomai, I; Bonazzoli, E; Ratner, E; Silasi, D-A; Azodi, M; Schwartz, P E; Rutherford, T J; Santin, A D
2014-10-28
Uterine serous carcinomas (USCs) are an aggressive form of uterine cancer that may rely on HER2/neu amplification as a driver of proliferation. The objective of this paper is to assess the sensitivity of USC cell lines with and without HER2/neu gene amplification to afatinib, an irreversible ErbB tyrosine kinase inhibitor, and to test the efficacy of afatinib in the treatment of HER2-amplified USC xenografts. Eight of fifteen primary USC cell lines (four with HER2 amplification and four without) demonstrating similar in vitro growth rates were treated with scalar concentrations of afatinib. Effects on cell growth, signalling and cell cycle distribution were determined by flow cytometry assays. Mice harbouring xenografts of HER2/neu-amplified USC were treated with afatinib by gavage to determine the effect on tumour growth and overall survival. Primary chemotherapy-resistant USC cell lines harbouring HER2/neu gene amplification were exquisitely sensitive to afatinib exposure (mean ± s.e.m. IC50=0.0056 ± 0.0006 μM) and significantly more sensitive than HER2/neu-non-amplified USC cell lines (mean ± s.e.m. IC50=0.563 ± 0.092 μM, P<0.0001). Afatinib exposure resulted in abrogation of cell survival, inhibition of HER2/neu autophosphorylation and S6 transcription factor phosphorylation in HER2/neu overexpressing USC and inhibited the growth of HER2-amplified tumour xenografts improving overall survival (P=0.0017). Afatinib may be highly effective against HER2/neu-amplified chemotherapy-resistant USC. The investigation of afatinib in patients harbouring HER2/neu-amplified USC is warranted.
K-Ras(G12D)-selective inhibitory peptides generated by random peptide T7 phage display technology.
Sakamoto, Kotaro; Kamada, Yusuke; Sameshima, Tomoya; Yaguchi, Masahiro; Niida, Ayumu; Sasaki, Shigekazu; Miwa, Masanori; Ohkubo, Shoichi; Sakamoto, Jun-Ichi; Kamaura, Masahiro; Cho, Nobuo; Tani, Akiyoshi
2017-03-11
Amino-acid mutations of Gly 12 (e.g. G12D, G12V, G12C) of V-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (K-Ras), the most promising drug target in cancer therapy, are major growth drivers in various cancers. Although over 30 years have passed since the discovery of these mutations in most cancer patients, effective mutated K-Ras inhibitors have not been marketed. Here, we report novel and selective inhibitory peptides to K-Ras(G12D). We screened random peptide libraries displayed on T7 phage against purified recombinant K-Ras(G12D), with thorough subtraction of phages bound to wild-type K-Ras, and obtained KRpep-2 (Ac-RRCPLYISYDPVCRR-NH 2 ) as a consensus sequence. KRpep-2 showed more than 10-fold binding- and inhibition-selectivity to K-Ras(G12D), both in SPR analysis and GDP/GTP exchange enzyme assay. K D and IC 50 values were 51 and 8.9 nM, respectively. After subsequent sequence optimization, we successfully generated KRpep-2d (Ac-RRRRCPLYISYDPVCRRRR-NH 2 ) that inhibited enzyme activity of K-Ras(G12D) with IC 50 = 1.6 nM and significantly suppressed ERK-phosphorylation, downstream of K-Ras(G12D), along with A427 cancer cell proliferation at 30 μM peptide concentration. To our knowledge, this is the first report of a K-Ras(G12D)-selective inhibitor, contributing to the development and study of K-Ras(G12D)-targeting drugs. Copyright © 2017 Elsevier Inc. All rights reserved.
Bacterial Infochemicals are Drivers of Algal Lysis
NASA Astrophysics Data System (ADS)
Whalen, K.; Deering, R.; Rowley, D. C.; El Gamal, A.; Schorn, M.; Moore, B. S.; Johnson, M. D.; Mincer, T. J.; Harvey, E.
2016-02-01
Processing of organic matter by bacteria forces oceanic biogeochemical cycles, food web structure and ultimately environmental stoichiometry. A newly emerging picture of the microbial loop suggests that bacteria are not merely passive recipients of dissolved organic matter (DOM) from phytoplankton exudate. Rather, heterotrophic bacteria can mediate the flow of DOM by actively producing soluble algicidal compounds. However, deciphering those chemical signals that determine these interactions has remained a challenge. Here, we report the isolation of 2-heptyl-4-quinolone (HHQ), released by Pseudoalteromonas piscicida, a marine gamma-proteobacteria isolated from plastic debris in the North Atlantic. Both 2-heptyl-3-hydroxy-4-quinolone and its immediate precursor, HHQ are known to function as antibiotics and quorum sensing signaling molecules with crucial roles in virulence, and apoptosis in eukaryotic cells (e.g. fungi and mammalian cells). Our ecologically-relevant screening of live cells and filtrate from P. piscicida cultures caused a significant decrease in the growth rate of the bloom-forming coccolithophore, Emiliania huxleyi. Bioassay-guided fraction of P. piscicida extracellular crude extracts identified HHQ, which induced mortality in three strains of E. huxleyi with an IC50 in the nanomolar range. In contrast, the marine chlorophyte, Dunaliella tertiolecta and diatom, Phaeodactylum tricornutum were unaffected by HHQ exposures (IC50 > 10 micromolar), but were susceptible to extracts of P. piscicida, indicating this bacterium may produce a cocktail of algicidal compounds specific to different phytoplankton guilds. The ability of HHQ to influence phytoplankton growth suggests that alkylquinolone-signaling molecules play a fundamental role in interkingdom interactions, ultimately influencing shifts in phytoplankton population dynamics. This study implicates a new role for HHQ beyond its importance in quorum sensing.
Breast tumors from CHEK2 1100delC-mutation carriers: genomic landscape and clinical implications.
Muranen, Taru A; Greco, Dario; Fagerholm, Rainer; Kilpivaara, Outi; Kämpjärvi, Kati; Aittomäki, Kristiina; Blomqvist, Carl; Heikkilä, Päivi; Borg, Ake; Nevanlinna, Heli
2011-09-20
Checkpoint kinase 2 (CHEK2) is a moderate penetrance breast cancer risk gene, whose truncating mutation 1100delC increases the risk about twofold. We investigated gene copy-number aberrations and gene-expression profiles that are typical for breast tumors of CHEK2 1100delC-mutation carriers. In total, 126 breast tumor tissue specimens including 32 samples from patients carrying CHEK2 1100delC were studied in array-comparative genomic hybridization (aCGH) and gene-expression (GEX) experiments. After dimensionality reduction with CGHregions R package, CHEK2 1100delC-associated regions in the aCGH data were detected by the Wilcoxon rank-sum test. The linear model was fitted to GEX data with R package limma. Genes whose expression levels were associated with CHEK2 1100delC mutation were detected by the bayesian method. We discovered four lost and three gained CHEK2 1100delC-related loci. These include losses of 1p13.3-31.3, 8p21.1-2, 8p23.1-2, and 17p12-13.1 as well as gains of 12q13.11-3, 16p13.3, and 19p13.3. Twenty-eight genes located on these regions showed differential expression between CHEK2 1100delC and other tumors, nominating them as candidates for CHEK2 1100delC-associated tumor-progression drivers. These included CLCA1 on 1p22 as well as CALCOCO1, SBEM, and LRP1 on 12q13. Altogether, 188 genes were differentially expressed between CHEK2 1100delC and other tumors. Of these, 144 had elevated and 44, reduced expression levels.Our results suggest the WNT pathway as a driver of tumorigenesis in breast tumors of CHEK2 1100delC-mutation carriers and a role for the olfactory receptor protein family in cancer progression. Differences in the expression of the 188 CHEK2 1100delC-associated genes divided breast tumor samples from three independent datasets into two groups that differed in their relapse-free survival time. We have shown that copy-number aberrations of certain genomic regions are associated with CHEK2 mutation 1100delC. On these regions, we identified potential drivers of CHEK2 1100delC-associated tumorigenesis, whose role in cancer progression is worth investigating. Furthermore, poorer survival related to the CHEK2 1100delC gene-expression signature highlights pathways that are likely to have a role in the development of metastatic disease in carriers of the CHEK2 1100delC mutation.
Breast tumors from CHEK2 1100delC-mutation carriers: genomic landscape and clinical implications
2011-01-01
Introduction Checkpoint kinase 2 (CHEK2) is a moderate penetrance breast cancer risk gene, whose truncating mutation 1100delC increases the risk about twofold. We investigated gene copy-number aberrations and gene-expression profiles that are typical for breast tumors of CHEK2 1100delC-mutation carriers. Methods In total, 126 breast tumor tissue specimens including 32 samples from patients carrying CHEK2 1100delC were studied in array-comparative genomic hybridization (aCGH) and gene-expression (GEX) experiments. After dimensionality reduction with CGHregions R package, CHEK2 1100delC-associated regions in the aCGH data were detected by the Wilcoxon rank-sum test. The linear model was fitted to GEX data with R package limma. Genes whose expression levels were associated with CHEK2 1100delC mutation were detected by the bayesian method. Results We discovered four lost and three gained CHEK2 1100delC-related loci. These include losses of 1p13.3-31.3, 8p21.1-2, 8p23.1-2, and 17p12-13.1 as well as gains of 12q13.11-3, 16p13.3, and 19p13.3. Twenty-eight genes located on these regions showed differential expression between CHEK2 1100delC and other tumors, nominating them as candidates for CHEK2 1100delC-associated tumor-progression drivers. These included CLCA1 on 1p22 as well as CALCOCO1, SBEM, and LRP1 on 12q13. Altogether, 188 genes were differentially expressed between CHEK2 1100delC and other tumors. Of these, 144 had elevated and 44, reduced expression levels. Our results suggest the WNT pathway as a driver of tumorigenesis in breast tumors of CHEK2 1100delC-mutation carriers and a role for the olfactory receptor protein family in cancer progression. Differences in the expression of the 188 CHEK2 1100delC-associated genes divided breast tumor samples from three independent datasets into two groups that differed in their relapse-free survival time. Conclusions We have shown that copy-number aberrations of certain genomic regions are associated with CHEK2 mutation 1100delC. On these regions, we identified potential drivers of CHEK2 1100delC-associated tumorigenesis, whose role in cancer progression is worth investigating. Furthermore, poorer survival related to the CHEK2 1100delC gene-expression signature highlights pathways that are likely to have a role in the development of metastatic disease in carriers of the CHEK2 1100delC mutation. PMID:21542898
Fakih, Mohamad G; Skierczynski, Boguslow; Bufalino, Angelo; Groves, Clariecia; Roberts, Phillip; Heavens, Michelle; Hendrich, Ann; Haydar, Ziad
2016-12-01
The standardized infection ratio (SIR) evaluates individual publicly reported health care-associated infections, but it may not assess overall performance. We piloted an infection composite score (ICS) in 82 hospitals of a single health system. The ICS is a combined score for central line-associated bloodstream infections, catheter-associated urinary tract infections, colon and abdominal hysterectomy surgical site infections, and hospital-onset methicillin-resistant Staphylococcus aureus bacteremia and Clostridium difficile infections. Individual facility ICSs were calculated by normalizing each of the 6 SIR events to the system SIR for baseline and performance periods (ICS ib and ICS ip , respectively). A hospital ICS ib reflected its baseline performance compared with system baseline, whereas a ICS ip provided information of its outcome changes compared with system baseline. Both the ICS ib (baseline 2013) and ICS ip (performance 2014) were calculated for 63 hospitals (reporting at least 4 of the 6 event types). The ICS ip improved in 36 of 63 (57.1%) hospitals in 2014 when compared with the ICS ib in 2013. The ICS ib 2013 median was 0.96 (range, 0.13-2.94) versus the 2014 ICS ip median of 0.92 (range, 0-6.55). Variation was more evident in hospitals with ≤100 beds. The system performance score (ICS sp ) in 2014 was 0.95, a 5% improvement compared with 2013. The proposed ICS may help large health systems and state hospital associations better evaluate key infectious outcomes, comparing them with historic and concurrent performance of peers. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Integrated circuit failure analysis by low-energy charge-induced voltage alteration
Cole, E.I. Jr.
1996-06-04
A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs. 5 figs.
Integrated circuit failure analysis by low-energy charge-induced voltage alteration
Cole, Jr., Edward I.
1996-01-01
A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs.
Temporal and developmental requirements for the Prader–Willi imprinting center
DuBose, Amanda J.; Smith, Emily Y.; Johnstone, Karen A.; Resnick, James L.
2012-01-01
Imprinted gene expression associated with Prader–Willi syndrome (PWS) and Angelman syndrome (AS) is controlled by two imprinting centers (ICs), the PWS-IC and the AS-IC. The PWS-IC operates in cis to activate transcription of genes that are expressed exclusively from the paternal allele. We have created a conditional allele of the PWS-IC to investigate its developmental activity. Deletion of the paternal PWS-IC in the embryo before implantation abolishes expression of the paternal-only genes in the neonatal brain. Surprisingly, deletion of the PWS-IC in early brain progenitors does not affect the subsequent imprinted status of PWS/AS genes in the newborn brain. These results indicate that the PWS-IC functions to protect the paternal epigenotype at the epiblast stage of development but is dispensable thereafter. PMID:22331910
Parental intermittent claudication as risk factor for claudication in adults.
Prushik, Scott G; Farber, Alik; Gona, Philimon; Shrader, Peter; Pencina, Michael J; D'Agostino, Ralph B; Murabito, Joanne M
2012-03-01
Little is known about the familial aggregation of intermittent claudication (IC). Our objective was to examine whether parental IC increased the risk of IC in adult offspring, independent of the established cardiovascular risk factors. We evaluated the Offspring Cohort Participants of the Framingham Heart Study who were ≥30 years old, cardiovascular disease free, and had both parents enrolled in the Framingham Heart Study (n = 2,970 unique participants, 53% women). Pooled proportional hazards regression analysis was used to examine whether the 12-year risk of incident IC in offspring participants was associated with parental IC, adjusting for age, gender, diabetes, smoking, systolic blood pressure, total cholesterol, high-density lipoprotein cholesterol, and antihypertensive and lipid treatment. Of the 909 person-examinations in the parental IC history group and 5,397 person-examinations in the no-parental IC history group, there were 101 incident IC events (29 with parental IC history and 72 without a parental IC history) during follow-up. The age- and gender-adjusted 12-year cumulative incidence rate per 1,000 person-years was 5.08 (95% confidence interval [CI] 2.74 to 7.33) and 2.34 (95% CI 1.46 to 3.19) in participants with and without a parental IC history. A parental history of IC significantly increased the risk of incident IC in the offspring (multivariable adjusted hazard ratio 1.81, 95% CI 1.14 to 2.88). The hazard ratio was unchanged, with an adjustment for the occurrence of cardiovascular disease (hazard ratio 1.83, 95% CI 1.15 to 2.91). In conclusion, IC in parents increases the risk of IC in adult offspring, independent of the established risk factors. These data suggest a genetic component of peripheral artery disease and support future research into genetic causes. Copyright © 2012 Elsevier Inc. All rights reserved.
Pilishvili, Tamara; Loo, Jennifer D.; Schrag, Stephanie; Stanistreet, Debbi; Christensen, Bryan; Yip, Fuyuen; Nyagol, Ronald; Quick, Robert; Sage, Mike; Bruce, Nigel
2016-01-01
Background Household air pollution (HAP) from biomass fuel burning is linked to poor health outcomes. Improved biomass cookstoves (ICS) have the potential to improve HAP. Objectives A pre-/post- intervention study assessed the impact of six ICS on indoor air quality and acceptability of ICS to local users in rural Western Kenya. Methods We measured mean personal and kitchen level concentrations of particulate matter <2.5μm in diameter (PM2.5, μg/m3) and carbon monoxide (CO, ppm) during the 48-hour period of each ICS use in 45 households. We compared these levels to those observed with traditional 3-stone fire (TSF) use. We assessed ICS acceptability through interviews and focus groups. We evaluated association of stove type, fuel use, and factors related to cooking practices with mean kitchen PM2.5 and CO using multivariable regression. Results Stove type, exclusive ICS use (vs. concurrent TSF use), and the amount of fuel used were independently associated with kitchen PM2.5 and CO levels. Reductions (95%CI) in mean PM2.5 compared to TSF, ranged by ICS from 11.9% (-2.8–24.5) to 42.3% (32.3–50.8). Reductions in kitchen CO compared to TSF, ranged by ICS from -5.8% (-21.9–8.2) to 34.5% (23.2–44.1). Mean kitchen PM2.5 ranged from 319μg/m3 to 518μg/m3 by ICS. Women thought ICS were easy to use, more efficient, produced less smoke, and cooked faster, compared to TSF. Women also reported limitations for each ICS. Conclusions We documented reductions in HAP from ICS compared to TSF. The PM2.5 levels with ICS use were still considerably higher than WHO indoor air quality guidelines. Achieving maximal potential of ICS requires adherence to more exclusive use and addressing user reported ICS limitations. PMID:27846224
(Epi)genotype–phenotype correlations in Beckwith–Wiedemann syndrome
Mussa, Alessandro; Russo, Silvia; De Crescenzo, Agostina; Freschi, Andrea; Calzari, Luciano; Maitz, Silvia; Macchiaiolo, Marina; Molinatto, Cristina; Baldassarre, Giuseppina; Mariani, Milena; Tarani, Luigi; Bedeschi, Maria Francesca; Milani, Donatella; Melis, Daniela; Bartuli, Andrea; Cubellis, Maria Vittoria; Selicorni, Angelo; Cirillo Silengo, Margherita; Larizza, Lidia; Riccio, Andrea; Ferrero, Giovanni Battista
2016-01-01
Beckwith–Wiedemann syndrome (BWS) is characterized by cancer predisposition, overgrowth and highly variable association of macroglossia, abdominal wall defects, nephrourological anomalies, nevus flammeus, ear malformations, hypoglycemia, hemihyperplasia, and organomegaly. BWS molecular defects, causing alteration of expression or activity of the genes regulated by two imprinting centres (IC) in the 11p15 chromosomal region, are also heterogeneous. In this paper we define (epi)genotype–phenotype correlations in molecularly confirmed BWS patients. The characteristics of 318 BWS patients with proven molecular defect were compared among the main four molecular subclasses: IC2 loss of methylation (IC2-LoM, n=190), IC1 gain of methylation (IC1-GoM, n=31), chromosome 11p15 paternal uniparental disomy (UPD, n=87), and cyclin-dependent kinase inhibitor 1C gene (CDKN1C) variants (n=10). A characteristic growth pattern was found in each group; neonatal macrosomia was almost constant in IC1-GoM, postnatal overgrowth in IC2-LoM, and hemihyperplasia more common in UPD (P<0.001). Exomphalos was more common in IC2/CDKN1C patients (P<0.001). Renal defects were typical of UPD/IC1 patients, uretheral malformations of IC1-GoM cases (P<0.001). Ear anomalies and nevus flammeus were associated with IC2/CDKN1C genotype (P<0.001). Macroglossia was less common among UPD patients (P<0.001). Wilms' tumor was associated with IC1-GoM or UPD and never observed in IC2-LoM patients (P<0.001). Hepatoblastoma occurred only in UPD cases. Cancer risk was lower in IC2/CDKN1C, intermediate in UPD, and very high in IC1 cases (P=0.009). In conclusion, (epi)genotype–phenotype correlations define four different phenotypic BWS profiles with some degree of clinical overlap. These observations impact clinical care allowing to move toward (epi) genotype-based follow-up and cancer screening. PMID:25898929
Pilishvili, Tamara; Loo, Jennifer D; Schrag, Stephanie; Stanistreet, Debbi; Christensen, Bryan; Yip, Fuyuen; Nyagol, Ronald; Quick, Robert; Sage, Mike; Bruce, Nigel
2016-01-01
Household air pollution (HAP) from biomass fuel burning is linked to poor health outcomes. Improved biomass cookstoves (ICS) have the potential to improve HAP. A pre-/post- intervention study assessed the impact of six ICS on indoor air quality and acceptability of ICS to local users in rural Western Kenya. We measured mean personal and kitchen level concentrations of particulate matter <2.5μm in diameter (PM2.5, μg/m3) and carbon monoxide (CO, ppm) during the 48-hour period of each ICS use in 45 households. We compared these levels to those observed with traditional 3-stone fire (TSF) use. We assessed ICS acceptability through interviews and focus groups. We evaluated association of stove type, fuel use, and factors related to cooking practices with mean kitchen PM2.5 and CO using multivariable regression. Stove type, exclusive ICS use (vs. concurrent TSF use), and the amount of fuel used were independently associated with kitchen PM2.5 and CO levels. Reductions (95%CI) in mean PM2.5 compared to TSF, ranged by ICS from 11.9% (-2.8-24.5) to 42.3% (32.3-50.8). Reductions in kitchen CO compared to TSF, ranged by ICS from -5.8% (-21.9-8.2) to 34.5% (23.2-44.1). Mean kitchen PM2.5 ranged from 319μg/m3 to 518μg/m3 by ICS. Women thought ICS were easy to use, more efficient, produced less smoke, and cooked faster, compared to TSF. Women also reported limitations for each ICS. We documented reductions in HAP from ICS compared to TSF. The PM2.5 levels with ICS use were still considerably higher than WHO indoor air quality guidelines. Achieving maximal potential of ICS requires adherence to more exclusive use and addressing user reported ICS limitations.
A high ratio of IC31® adjuvant to antigen is necessary for H4 TB vaccine immunomodulation
Aboutorabian, Sepideh; Hakimi, Jalil; Boudet, Florence; Montano, Sandrine; Dookie, Annie; Roque, Cristopher; Ausar, Salvador F; Rahman, Nausheen; Brookes, Roger H
2015-01-01
A tuberculosis (TB) vaccine consisting of a recombinant fusion protein (H4) and a novel TLR9 adjuvant (IC31) is in clinical development. To better understand the H4-IC31 ratio, we measured the binding capacity of IC31 for H4 protein and immunized mice with formulations that contained limiting to excess ratios of IC31 to H4. An immunomodulated H4-specific IFNγ response was only observed when IC31 was present in excess of H4. Since TLR expression is species-specific and the vaccine is intended to boost BCG-primed immunity, we questioned whether data in mice would translate to humans. To address this question, we used the fresh human Whole Blood (hWB) recovered from BCG-vaccinated subjects to screen H4-IC31 formulations. We found IC31 modulation in hWB to be quite distinct from the TLR4-Adjuvant. Unlike TLR4-Adjuvant, IC31 formulations did not induce the pro-inflammatory cytokine TNFα, but modulated a robust H4-specific IFNγ response after 12 d of culture. We then re-stimulated the fresh hWB of 5 BCG-primed subjects with formulations that had excess or limiting IC31 binding for H4 protein and again found that an immunomodulated H4-specific IFNγ response needed an excess of IC31. Finally, we monitored the zeta (ζ) potential of H4-IC31 formulations and found that the overall charge of H4-IC31 particles changes from negative to positive once IC31 is in greater than 9-fold excess. Using two diverse yet mutually supportive approaches, we confirm the need for an excess of IC31 adjuvant in H4 TB vaccine formulations and suggest surface potential may be an important factor. PMID:25997147
A high ratio of IC31(®) adjuvant to antigen is necessary for H4 TB vaccine immunomodulation.
Aboutorabian, Sepideh; Hakimi, Jalil; Boudet, Florence; Montano, Sandrine; Dookie, Annie; Roque, Cristopher; Ausar, Salvador F; Rahman, Nausheen; Brookes, Roger H
2015-01-01
A tuberculosis (TB) vaccine consisting of a recombinant fusion protein (H4) and a novel TLR9 adjuvant (IC31) is in clinical development. To better understand the H4-IC31 ratio, we measured the binding capacity of IC31 for H4 protein and immunized mice with formulations that contained limiting to excess ratios of IC31 to H4. An immunomodulated H4-specific IFNγ response was only observed when IC31 was present in excess of H4. Since TLR expression is species-specific and the vaccine is intended to boost BCG-primed immunity, we questioned whether data in mice would translate to humans. To address this question, we used the fresh human Whole Blood (hWB) recovered from BCG-vaccinated subjects to screen H4-IC31 formulations. We found IC31 modulation in hWB to be quite distinct from the TLR4-Adjuvant. Unlike TLR4-Adjuvant, IC31 formulations did not induce the pro-inflammatory cytokine TNFα, but modulated a robust H4-specific IFNγ response after 12 d of culture. We then re-stimulated the fresh hWB of 5 BCG-primed subjects with formulations that had excess or limiting IC31 binding for H4 protein and again found that an immunomodulated H4-specific IFNγ response needed an excess of IC31. Finally, we monitored the zeta (ζ) potential of H4-IC31 formulations and found that the overall charge of H4-IC31 particles changes from negative to positive once IC31 is in greater than 9-fold excess. Using two diverse yet mutually supportive approaches, we confirm the need for an excess of IC31 adjuvant in H4 TB vaccine formulations and suggest surface potential may be an important factor.
Pivnick, K A
1993-09-01
Trapping experiments were carried out near Saskatoon, Canada, from May through August 1990 to assess the response of the braconid wasp,Meteorus leviventris, to four selected mustard oils or isothiocyanates (IC) at a release rate of 4 mg/day, and for allyl IC only, at 40 mg/day. Only allyl IC at 4 mg/day was significantly attractive when trap captures were compared to the captures in the control traps. The others (n-propyl IC, 2-phenylethyl IC., and ethyl IC) were not attractive, nor was allyl IC at the higher dose, although trap captures with the latter bait were the second highest.
Individual Differences in Inhibitory Control Skills at Three Years of Age
Watson, Amanda J.; Bell, Martha Ann
2013-01-01
Sixty-eight 3-year-old children participated in an investigation of inhibitory control (IC). Child IC was measured using various tasks in order to determine the impact on child performance of manipulating task demands. Performance on a nonverbal IC task, but not performance on more difficult motivational or traditional IC tasks, was explained by medial frontal electroencephalographic activity and by language abilities. Because of the unique relations of nonverbal IC with concurrent developmental measures, and because of its potential to predict later social problems, we conclude that it is important to include nonverbal IC measures in investigative IC batteries in early childhood. PMID:23311312
Vorhees, Charles V; Graham, Devon L; Braun, Amanda A; Schaefer, Tori L; Skelton, Matthew R; Richtand, Neil M; Williams, Michael T
2015-01-01
Prenatal maternal immune activation increases risk for schizophrenia and/or autism. Previous data suggest that maternal weight change in response to the immune activator polyinosinic-polycytidylic (Poly IC) in rats influences the severity of effect in the offspring as does the exposure period. We treated gravid Sprague-Dawley rats from E14 to 18 with 8mg/kg/day Poly IC or saline. The Poly IC group was divided into those that gained the least weight or lost (Poly IC (L)) and those that gained the most (Poly IC (H)) weight. There were no effects of Poly IC on anxiety (elevated zero-maze, open-field, object burying), or Morris water maze cued learning or working memory or Cincinnati water maze egocentric learning. The Poly IC (H) group males had decreased acoustic startle whereas Poly IC (L) females had reduced startle and increased PPI. Poly IC offspring showed exaggerated hyperactivity in response to amphetamine (primarily in the Poly IC (H) group) and attenuated hyperactivity in response to MK-801 challenge (primarily in the Poly IC (L) group). Poly IC (L) males showed reduced cued conditioned freezing; both sexes showed less time in the dark in a light-dark test, and the Poly IC groups showed impaired Morris water maze hidden platform acquisition and probe performance. The data demonstrate that offspring from the most affected dams were more affected than those from less reactive dams indicating that degree of maternal immune activation predicts severity of effects on offspring behavior. Copyright © 2014 Elsevier Inc. All rights reserved.
Bladder pain syndrome/interstitial cystitis as a functional somatic syndrome.
Warren, John W
2014-12-01
To determine whether bladder pain syndrome/interstitial cystitis (BPS/IC) has the characteristics of a functional somatic syndrome (FSS). There is no accepted definition of an FSS. Consequently, this paper reviewed the literature for common FSS characteristics and for reports that BPS/IC has these characteristics. Eleven articles met inclusion and exclusion criteria and yielded 18 FSS characteristics. BPS/IC patients manifest all but two: the exceptions were normal light microscopic anatomy (after hydrodistention under anesthesia, some BPS/IC bladders have Hunner's lesions and most have petechial hemorrhages) and normal laboratory tests (many BPS/IC patients have hematuria). Petechial hemorrhages and hematuria are probably related and may appear during naturally-occurring bladder distention. Without such distention, then, the 90% of BPS/IC patients without a Hunner's lesion have all the characteristics of an FSS. Comparisons in the opposite direction were consistent: several additional features of BPS/IC were found in FSSs. This systematic but untested method is consistent with but does not test the hypothesis that BPS/IC in some patients might best be understood as an FSS. Like most conditions, BPS/IC is probably heterogeneous; hence only a proportion of BPS/IC cases are likely to be manifestations of an FSS. This hypothesis has several implications. Explorations of processes that connect the FSSs might contribute to understanding the pathogenesis of BPS/IC. Patients with FSSs are at risk for BPS/IC and may benefit from future preventive strategies. Therapies that are useful in FSSs also may be useful in some cases of BPS/IC. Copyright © 2014 Elsevier Inc. All rights reserved.
/ARW1 : IC/BC from 6-h old GFS Alaska ARW2 : IC from current NAM, BC from 6-h old NAM CONUS NMMB/ARW1 : IC from current RAP, BC from 6-h old GFS CONUS ARW2 ; IC from current NAM, BC from 6-h old NAM Hawaii NMMB/ARW1: IC/BC from 6-h old GFS Hawaii ARW2 : IC from current NAM, BC from 6-h old NAM Puerto Rico
Aytac, Zeynep; Yildiz, Zehra Irem; Kayaci-Senirmak, Fatma; San Keskin, Nalan Oya; Kusku, Semran Ipek; Durgun, Engin; Tekinay, Turgay; Uyar, Tamer
2016-10-05
We have proposed a new strategy for preparing free-standing nanofibrous webs from an inclusion complex (IC) of a well-known flavor/fragrance compound (limonene) with three modified cyclodextrins (HPβCD, MβCD, and HPγCD) via electrospinning (CD/limonene-IC-NFs) without using a polymeric matrix. The experimental and computational modeling studies proved that the stoichiometry of the complexes was 1:1 for CD/limonene systems. MβCD/limonene-IC-NF released much more limonene at 37, 50, and 75 °C than HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF because of the greater amount of preserved limonene. Moreover, MβCD/limonene-IC-NF has released only 25% (w/w) of its limonene, whereas HPβCD/limonene-IC-NF and HPγCD/limonene-IC-NF released 51 and 88% (w/w) of their limonene in 100 days, respectively. CD/limonene-IC-NFs exhibited high antibacterial activity against E. coli and S. aureus. The water solubility of limonene increased significantly and CD/limonene-IC-NFs were dissolved in water in a few seconds. In brief, CD/limonene-IC-NFs with fast-dissolving character enhanced the thermal stability and prolonged the shelf life along with antibacterial properties could be quite applicable in food and oral care applications.
Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne
2018-01-01
Introduction Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. Materials and methods A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. Results The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. Discussion The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the intercultural experience and the current global discourse. Longitudinal studies with representative samples are required to assess how IC definitions change over time. PMID:29698525
NASA Astrophysics Data System (ADS)
Holt, Jason; Icarus Allen, J.; Anderson, Thomas R.; Brewin, Robert; Butenschön, Momme; Harle, James; Huse, Geir; Lehodey, Patrick; Lindemann, Christian; Memery, Laurent; Salihoglu, Baris; Senina, Inna; Yool, Andrew
2014-12-01
It has long been recognised that there are strong interactions and feedbacks between climate, upper ocean biogeochemistry and marine food webs, and also that food web structure and phytoplankton community distribution are important determinants of variability in carbon production and export from the euphotic zone. Numerical models provide a vital tool to explore these interactions, given their capability to investigate multiple connected components of the system and the sensitivity to multiple drivers, including potential future conditions. A major driver for ecosystem model development is the demand for quantitative tools to support ecosystem-based management initiatives. The purpose of this paper is to review approaches to the modelling of marine ecosystems with a focus on the North Atlantic Ocean and its adjacent shelf seas, and to highlight the challenges they face and suggest ways forward. We consider the state of the art in simulating oceans and shelf sea physics, planktonic and higher trophic level ecosystems, and look towards building an integrative approach with these existing tools. We note how the different approaches have evolved historically and that many of the previous obstacles to harmonisation may no longer be present. We illustrate this with examples from the on-going and planned modelling effort in the Integrative Modelling Work Package of the EURO-BASIN programme.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janardhanraj, S.; Jagadeesh, G., E-mail: jaggie@aero.iisc.ernet.in
A novel concept to generate miniature shockwaves in a safe, repeatable, and controllable manner in laboratory confinements using an in situ oxyhydrogen generator has been proposed and demonstrated. This method proves to be more advantageous than existing methods because there is flexibility to vary strength of the shockwave, there is no need for storage of high pressure gases, and there is minimal waste disposal. The required amount of oxyhydrogen mixture is generated using alkaline electrolysis that produces hydrogen and oxygen gases in stoichiometric quantity. The rate of oxyhydrogen mixture production for the newly designed oxyhydrogen generator is found to bemore » around 8 ml/s experimentally. The oxyhydrogen generator is connected to the driver section of a specially designed 10 mm square miniature shock tube assembly. A numerical code that uses CANTERA software package is used to predict the properties of the driver gas in the miniature shock tube. This prediction along with the 1-D shock tube theory is used to calculate the properties of the generated shockwave and matches reasonably well with the experimentally obtained values for oxyhydrogen mixture fill pressures less than 2.5 bars. The miniature shock tube employs a modified tri-clover clamp assembly to facilitate quick changing of diaphragm and replaces the more cumbersome nut and bolt system of fastening components. The versatile nature of oxyhydrogen detonation-driven miniature shock tube opens up new horizons for shockwave-assisted interdisciplinary applications.« less
NASA Astrophysics Data System (ADS)
Källhammer, Jan-Erik; Pettersson, Håkan; Eriksson, Dick; Junique, Stéphane; Savage, Susan; Vieider, Christian; Andersson, Jan Y.; Franks, John; Van Nylen, Jan; Vercammen, Hans; Kvisterøy, Terje; Niklaus, Frank; Stemme, Göran
2006-04-01
Pedestrian fatalities are around 15% of the traffic fatalities in Europe. A proposed EU regulation requires the automotive industry to develop technologies that will substantially decrease the risk for Vulnerable Road Users when hit by a vehicle. Automatic Brake Assist systems, activated by a suitable sensor, will reduce the speed of the vehicle before the impact, independent of any driver interaction. Long Wavelength Infrared technology is an ideal candidate for such sensors, but requires a significant cost reduction. The target necessary for automotive serial applications are well below the cost of systems available today. Uncooled bolometer arrays are the most mature technology for Long Wave Infrared with low-cost potential. Analyses show that sensor size and production yield along with vacuum packaging and the optical components are the main cost drivers. A project has been started to design a new Long Wave Infrared system with a ten times cost reduction potential, optimized for the pedestrian protection requirement. It will take advantage of the progress in Micro Electro-Mechanical Systems and Long Wave Infrared optics to keep the cost down. Deployable and pre-impact braking systems can become effective alternatives to passive impact protection systems solutions fulfilling the EU pedestrian protection regulation. Low-cost Long Wave Infrared sensors will be an important enabler to make such systems cost competitive, allowing high market penetration.
NASA Astrophysics Data System (ADS)
Iwamori, Hikaru; Albaréde, Francis; Nakamura, Hitomi
2010-11-01
In order to further our understanding of the global geochemical structure and mantle dynamics, a global isotopic data set of oceanic basalts was analyzed by Independent Component Analysis (ICA), a relatively new method of multivariate analysis. The data set consists of 2773 mid-ocean ridge basalts (MORB) and 1515 ocean island basalts (OIB) with five isotopic ratios of Pb, Nd and Sr. The data set spatially covers the major oceans and enables us to compare the results with global geophysical observations. Three independent components (ICs) have been found, two of which are essentially identical to those previously found for basalts from the Atlantic and Indian Oceans. The two ICs (IC1 and IC2) span a compositional plane that accounts for 95.7% of the sample variance, while the third IC (IC3) accounts for 3.7%. Based on the geochemical nature of ICs and a forward model concerning trace elemental and isotopic compositions, the origin of the ICs is discussed. IC1 discriminates OIB from MORB, and may be related to elemental fractionation associated with melting and the subsequent radiogenic in growth with an average recycling time of 0.8 to 2.4 Ga. IC2 tracks the regional provenance of both MORB and OIB and may be related to aqueous fluid-rock interaction and the subsequent radiogenic ingrowth with an average recycling time of 0.3 to 0.9 Ga. IC3 fingerprints upper continental crustal material and its high value appears in limited geographical and tectonic settings. Variations in the melt component (IC1) and in the aqueous fluid component (IC2) inherited in the mantle most likely reflect mid-ocean ridge and subduction zone processes, respectively. Long-term accumulation of dense materials rich in the IC1 melt component at the base of the convective mantle accounts for its longer recycling time with respect to that for less dense materials rich in the aqueous fluid component (IC2). IC2 broadly correlates with the seismic velocity structures of the lowermost mantle and electric conductivity around the mantle transition zones. We propose that IC2 reflects hydrogen distribution within the mantle and that several global domains enriched in hydrogen could exist as vertical sectors extending all the way down to the core-mantle boundary.
Accelerometer Method and Apparatus for Integral Display and Control Functions
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1996-01-01
Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.
McDonald, Thomas O; Michor, Franziska
2017-07-15
SIApopr (Simulating Infinite-Allele populations) is an R package to simulate time-homogeneous and inhomogeneous stochastic branching processes under a very flexible set of assumptions using the speed of C ++. The software simulates clonal evolution with the emergence of driver and passenger mutations under the infinite-allele assumption. The software is an application of the Gillespie Stochastic Simulation Algorithm expanded to a large number of cell types and scenarios, with the intention of allowing users to easily modify existing models or create their own. SIApopr is available as an R library on Github ( https://github.com/olliemcdonald/siapopr ). Supplementary data are available at Bioinformatics online. michor@jimmy.harvard.edu. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Clayton, Byron C.
2015-01-01
Successful corporate acquisitions require its managers to achieve substantial performance improvements in order to sufficiently cover acquisition premiums, the expected return of debt and equity investors, and the additional resources needed to capture synergies and accelerate growth. Acquirers understand that achieving the performance improvements necessary to cover these costs and create value for investors will most likely require a significant effort from mergers and acquisitions (M&A) management teams. This understanding drives the common and longstanding practice of offering hefty performance incentive packages to key managers, assuming that financial incentives will induce in-role and extra-role behaviors that drive organizational change and growth. The present study debunks the assumptions of this common M&A practice, providing quantitative evidence that shared vision and autonomous motivation are far more effective drivers of managerial performance than financial incentives. PMID:25610406
Accelerometer Method and Apparatus for Integral Display and Control Functions
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1998-01-01
Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.
Clayton, Byron C
2014-01-01
Successful corporate acquisitions require its managers to achieve substantial performance improvements in order to sufficiently cover acquisition premiums, the expected return of debt and equity investors, and the additional resources needed to capture synergies and accelerate growth. Acquirers understand that achieving the performance improvements necessary to cover these costs and create value for investors will most likely require a significant effort from mergers and acquisitions (M&A) management teams. This understanding drives the common and longstanding practice of offering hefty performance incentive packages to key managers, assuming that financial incentives will induce in-role and extra-role behaviors that drive organizational change and growth. The present study debunks the assumptions of this common M&A practice, providing quantitative evidence that shared vision and autonomous motivation are far more effective drivers of managerial performance than financial incentives.
SVGA and XGA active matrix microdisplays for head-mounted applications
NASA Astrophysics Data System (ADS)
Alvelda, Phillip; Bolotski, Michael; Brown, Imani L.
2000-03-01
The MicroDisplay Corporation's liquid crystal on silicon (LCOS) display devices are based on the union of several technologies with the extreme integration capability of conventionally fabricated CMOS substrates. The fast liquid crystal operation modes and new scalable high-performance pixel addressing architectures presented in this paper enable substantially improved color, contrast, and brightness while still satisfying the optical, packaging, and power requirements of portable applications. The entire suite of MicroDisplay's technologies was devised to create a line of mixed-signal application-specific integrated circuits (ASICs) in single-chip display systems. Mixed-signal circuits can integrate computing, memory, and communication circuitry on the same substrate as the display drivers and pixel array for a multifunctional complete system-on-a-chip. System-on-a-chip benefits also include reduced head supported weight requirements through the elimination of off-chip drive electronics.
Yu, Lin-Ling; Tao, Shi-Peng; Dong, Xiao-Yan; Sun, Yan
2013-08-30
To explore the details of protein uptake to polymer-grafted ion exchangers, Sepharose FF was modified with poly(ethylenimine) (PEI) to prepare anion exchanger of 10 different ionic capacities (ICs, 100-1220mmol/L). Adsorption equilibria and kinetics of bovine serum albumin (BSA) were then studied. It is found that ionic capacity, i.e., the coupling density of PEI, had significant effect on both adsorption capacity (qm) and effective protein diffusivity (De). With increasing ionic capacity, the qm value increased rapidly at IC<260mmol/L and then increased slowly till reaching a plateau at IC=600mmol/L. In the IC range of 100-600mmol/L, however, the De values kept at a low level (De/D0<0.07); it first decreased from 0.05±0.01 at IC=100mmol/L to 0.01±0.01 at IC=260mmol/L and then increased to 0.06±0.01 at IC=600mmol/L. Thereafter, sharp increases of the qm and De values [36% (from 201 to 273mg/mL) and 670% (from 0.06±0.01 to 0.49±0.04), respectively] were observed in the narrow range of IC from 600 to 740mmol/L. Finally, at IC>740mmol/L, the qm value decreased significantly while the De value increased moderately with increasing the IC. The results indicate that PEI chains played an important role in protein adsorption and transport. In brief, there was a critical IC (cIC) or PEI chain density, above which protein adsorption and transport behaviors changed drastically. The cIC was identified to be about 600mmol/L. Estimation of PEI grafting-layer thickness suggests that PEI chains formed an extended three-dimensional grafting-layer at IC>cIC, which provided high flexibility as well as accessibility of the chains for protein binding. Therefore, at IC>cIC, the adjacent PEI chains became close and flexible enough, leading to facilitated transport of adsorbed protein molecules by the interactions of neighboring chains mediated by the bound molecules. It is regarded as "chain delivery" effect. At the same time, improved accessibility of binding sites led the significant increase of binding capacity. The decrease of qm value at IC>740mmol/L is considered due to the decrease of effective porosity. The research has thus provided new insight into protein adsorption and transport in polymer-grafted ion-exchange media. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Raghupathy, Arun; Ghia, Karman; Ghia, Urmila
2008-11-01
Compact Thermal Models (CTM) to represent IC packages has been traditionally developed using the DELPHI-based (DEvelopment of Libraries of PHysical models for an Integrated design) methodology. The drawbacks of this method are presented, and an alternative method is proposed. A reduced-order model that provides the complete thermal information accurately with less computational resources can be effectively used in system level simulations. Proper Orthogonal Decomposition (POD), a statistical method, can be used to reduce the order of the degree of freedom or variables of the computations for such a problem. POD along with the Galerkin projection allows us to create reduced-order models that reproduce the characteristics of the system with a considerable reduction in computational resources while maintaining a high level of accuracy. The goal of this work is to show that this method can be applied to obtain a boundary condition independent reduced-order thermal model for complex components. The methodology is applied to the 1D transient heat equation.
Data Mining the Ogle-II I-band Database for Eclipsing Binary Stars
NASA Astrophysics Data System (ADS)
Ciocca, M.
2013-08-01
The OGLE I-band database is a searchable database of quality photometric data available to the public. During Phase 2 of the experiment, known as "OGLE-II", I-band observations were made over a period of approximately 1,000 days, resulting in over 1010 measurements of more than 40 million stars. This was accomplished by using a filter with a passband near the standard Cousins Ic. The database of these observations is fully searchable using the mysql database engine, and provides the magnitude measurements and their uncertainties. In this work, a program of data mining the OGLE I-band database was performed, resulting in the discovery of 42 previously unreported eclipsing binaries. Using the software package Peranso (Vanmuster 2011) to analyze the light curves obtained from OGLE-II, the eclipsing types, the epochs and the periods of these eclipsing variables were determined, to one part in 106. A preliminary attempt to model the physical parameters of these binaries was also performed, using the Binary Maker 3 software (Bradstreet and Steelman 2004).
Hamlet, Jason; Pierson, Lyndon; Bauer, Todd
2018-06-25
Supply chain security to detect, deter, and prevent the counterfeiting of networked and stand-alone integrated circuits (ICs) is critical to cyber security. Sandia National Laboratory researchers have developed IC ID to leverage Physically Unclonable Functions (PUFs) and strong cryptographic authentication to create a unique fingerprint for each integrated circuit. IC ID assures the authenticity of ICs to prevent tampering or malicious substitution.
Intratumoral immunocytokine treatment results in enhanced antitumor effects.
Johnson, Erik E; Lum, Hillary D; Rakhmilevich, Alexander L; Schmidt, Brian E; Furlong, Meghan; Buhtoiarov, Ilia N; Hank, Jacquelyn A; Raubitschek, Andrew; Colcher, David; Reisfeld, Ralph A; Gillies, Stephen D; Sondel, Paul M
2008-12-01
Immunocytokines (IC), consisting of tumor-specific monoclonal antibodies fused to the immunostimulatory cytokine interleukin 2 (IL2), exert significant antitumor effects in several murine tumor models. We investigated whether intratumoral (IT) administration of IC provided enhanced antitumor effects against subcutaneous tumors. Three unique ICs (huKS-IL2, hu14.18-IL2, and GcT84.66-IL2) were administered systemically or IT to evaluate their antitumor effects against tumors expressing the appropriate IC-targeted tumor antigens. The effect of IT injection of the primary tumor on a distant tumor was also evaluated. Here, we show that IT injection of IC resulted in enhanced antitumor effects against B16-KSA melanoma, NXS2 neuroblastoma, and human M21 melanoma xenografts when compared to intravenous (IV) IC injection. Resolution of both primary and distant subcutaneous tumors and a tumor-specific memory response were demonstrated following IT treatment in immunocompetent mice bearing NXS2 tumors. The IT effect of huKS-IL2 IC was antigen-specific, enhanced compared to IL2 alone, and dose-dependent. Hu14.18-IL2 also showed greater IT effects than IL2 alone. The antitumor effect of IT IC did not always require T cells since IT IC induced antitumor effects against tumors in both SCID and nude mice. Localization studies using radiolabeled (111)In-GcT84.66-IL2 IC confirmed that IT injection resulted in a higher concentration of IC at the tumor site than IV administration. In conclusion, we suggest that IT IC is more effective than IV administration against palpable tumors. Further testing is required to determine how to potentially incorporate IT administration of IC into an antitumor regimen that optimizes local and systemic anticancer therapy.
The pharmacological modulation of thrombin-induced cerebral thromboembolism in the rabbit.
May, G. R.; Paul, W.; Crook, P.; Butler, K. D.; Page, C. P.
1992-01-01
1. Intracarotid (i.c.) administration of thrombin induced a marked accumulation of 111indium-labelled platelets and 125I-labelled fibrinogen within the cranial vasculature of anaesthetized rabbits. 2. Thrombin (100 iu kg-1, i.c.) - induced platelet accumulation was completely abolished by pretreatment with desulphatohirudin (CGP 39393; 1 mg kg-1 i.c., 1 min prior to thrombin). Administration of CGP 39393 1 or 20 min after thrombin produced a significant reduction in platelet accumulation. 3. Intravenous (i.v.) administration of the platelet activating factor (PAF) receptor antagonist BN 52021 (10 mg kg-1) 5 min prior to thrombin (100 iu kg-1, i.c.) had no effect on platelet accumulation. 4. An inhibitor of NO biosynthesis, L-NG-nitro arginine methyl ester (L-NAME; 100 mg kg-1, i.c.), had no significant effect on the cranial platelet accumulation response to thrombin (10 iu kg-1, i.c.) when administered 5 min prior to thrombin. 5. Defibrotide (32 or 64 mg kg-1 bolus i.c. followed by 32 or 64 mg kg-1 h-1, i.c., infusion for 45 min) treatment begun 20 min after thrombin (100 iu kg-1, i.c.) did not significantly modify the cranial platelet accumulation response. 6. Cranial platelet accumulation induced by thrombin (100 iu kg-1, i.c.) was significantly reversed by the fibrinolytic drugs urokinase (20 iu kg-1, i.c., infusion for 45 min), anisoylated plasminogen streptokinase activator complex (APSAC) (200 micrograms kg-1, i.v. bolus) or recombinant tissue plasminogen activator (rt-PA; 100 micrograms kg-1, i.c. bolus followed by 20 micrograms kg-1 min-1, i.c., infusion for 45 min) administered 20 min after thrombin.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1504722
Sonnappa, Samatha; Martin, Richard; Israel, Elliot; Postma, Dirkje; van Aalderen, Wim; Burden, Annie; Usmani, Omar S; Price, David B
2017-01-01
Regular use of inhaled corticosteroids (ICS) in patients with obstructive lung diseases has been associated with a higher risk of pneumonia, particularly in COPD. The risk of pneumonia has not been previously evaluated in relation to ICS particle size and dose used. Historical cohort, UK database study of 23,013 patients with obstructive lung disease aged 12-80 years prescribed extra-fine or fine-particle ICS. The endpoints assessed during the outcome year were diagnosis of pneumonia, acute exacerbations and acute respiratory events in relation to ICS dose. To determine the association between ICS particle size, dose and risk of pneumonia in unmatched and matched treatment groups, logistic and conditional logistic regression models were used. 14788 patients were stepped-up to fine-particle ICS and 8225 to extra-fine ICS. On unmatched analysis, patients stepping-up to extra-fine ICS were significantly less likely to be coded for pneumonia (adjusted odds ratio [aOR] 0.60; 95% CI 0.37, 0.97]); experience acute exacerbations (adjusted risk ratio [aRR] 0.91; 95%CI 0.85, 0.97); and acute respiratory events (aRR 0.90; 95%CI 0.86, 0.94) compared with patients stepping-up to fine-particle ICS. Patients prescribed daily ICS doses in excess of 700 mcg (fluticasone propionate equivalent) had a significantly higher risk of pneumonia (OR [95%CI] 2.38 [1.17, 4.83]) compared with patients prescribed lower doses, irrespective of particle size. These findings suggest that patients with obstructive lung disease on extra-fine particle ICS have a lower risk of pneumonia than those on fine-particle ICS, with those receiving higher ICS doses being at a greater risk.
A Simple Data Logging System for Ballistic Applications
2006-07-01
6. AUTHOR(S) Thomas Kottke 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN...AMSRD-ARL-WM-TE Aberdeen Proving Ground, MD 21005-5066 8. PERFORMING ORGANIZATION REPORT NUMBER ARL-TR-3853 10. SPONSOR/MONITOR’S ACRONYM(S...IC2 PIC18F458-I/L-ND $185.50/25 IC SOCKET PLCC 44POS SMT for IC2 ED80010-ND $15.05/10 IC SRAM 512KX8 LP WIDE 32- SOIC IC1 and IC4 428-1075-ND $118.00
Parental and youth understanding of the informed consent process for pediatric endoscopy.
Jubbal, Kevin; Chun, Stanford; Chang, Jeremy; Zhang, Sherry; Terrones, Laura; Huang, Jeannie S
2015-06-01
Informed consent (IC) is an essential communication between patient/representative and physician that acknowledges patient autonomy; assent is the equivalent process performed between youth and physician. For clinical procedures involving youth, only the IC process between guardian/parent and physician is required to be performed. Nevertheless, experts recommend that youth undergo assent whenever possible. In the present study, we explored both parental and youth understanding of required IC elements in IC discussions before pediatric endoscopy. Following signing of IC documents on the day of endoscopy at a tertiary care academic medical center, youth and their parents underwent structured interviews to assess comprehension of key elements of the IC process. A total of 88 children and adolescents and their parents were evaluated. Two youth and 12 parents demonstrated comprehensive understanding of key IC elements for pediatric endoscopy. Suboptimal youth understanding was demonstrated for nature of the procedure (25% with adequate understanding) and related risks (17%), and alternatives (14%) to the procedure. Suboptimal parental understanding was demonstrated for procedure alternatives (24%). Youth overall understanding of IC varied by age, whereas parental global understanding of IC varied by physician. Understanding of IC performed for pediatric endoscopy could be improved in both parents and youth. Our findings suggest that interventions targeting parents, youth, and physicians may be helpful. Further study is needed to determine whether our findings are representative of IC understanding at other pediatric endoscopy centers.
Evaluation of the Tuberculosis Infection Control Training Center, Tajikistan, 2014–2015
Scott, C.; Mangan, J.; Tillova, Z.; Jensen, P. A.; Ahmedov, S.; Ismoilova, J.; Trusov, A.
2017-01-01
SUMMARY SETTING Training center on tuberculosis (TB) infection control (IC) for health care workers in the Central Asian Republics region. OBJECTIVE To assess the effects of TB IC training courses conducted at the Tuberculosis Infection Control Training Center in Machiton, Tajikistan. DESIGN Participants who participated in training (n = 89) during the first year of operation (April 2014–February 2015) were invited to participate in a post-training interview. RESULTS Of the 89 participants, 84 (94%) completed the interview and expressed satisfaction with the training. Eighty (95%) participants reported meeting with workplace leadership to discuss the training. Of these, 69 (85%) reported discussing changes required to meet TB IC standards. Self-reported changes in TB IC practices at work facilities post training included the creation of TB IC committees, designation of a TB IC focal person, TB IC planning, policies to separate infectious patients in waiting rooms, provision of masks for infectious patients, development of cough etiquette policies, improved glove availability, hand hygiene programs, and TB IC posters in waiting rooms. CONCLUSIONS Participant satisfaction and reported changes in TB IC activities illustrate the potential of these training courses to improve TB IC in the region. Future training courses may be tailored to specific audiences using a structured conceptual framework to impact administration, budgeting, and facilities management of TB IC practices. PMID:28399974
Cytotoxic activity of quassinoids from Eurycoma longifolia.
Miyake, Katsunori; Li, Feng; Tezuka, Yasuhiro; Awale, Suresh; Kadota, Shigetoshi
2010-07-01
Twenty-four quassinoids isolated from Eurycoma longifolia Jack were investigated for their cytotoxicity against a panel of four different cancer cell lines, which includes three murine cell lines [colon 26-L5 carcinoma (colon 26-L5), B16-BL6 melanoma (B16-BL6), Lewis lung carcinoma (LLC)] and a human lung A549 adenocarcinoma (A549) cell line. Among the tested compounds, eurycomalactone (9) displayed the most potent activity against all the tested cell lines; colon 26-L5 (IC50 = 0.70 microM), B16-BL6 (IC50 = 0.59 microM), LLC (IC50 = 0.78 microM), and A549 (IC50 = 0.73 microM). These activities were comparable to clinically used anticancer agent doxorubicin (colon 26-L5, IC50 = 0.76 microM; B16-BL6, IC50 = 0.86 microM; LLC, IC50 = 0.80 microM; A549, IC50 = 0.66 microM).
van Boven, Job F M; de Jong-van den Berg, Lolkje T W; Vegter, Stefan
2013-04-01
The primary aim of the study was to gain insight into the relative risk of clinically relevant oral candidiasis following inhaled corticosteroid (ICS) initiation over time. A secondary aim was to analyse the influence of patient characteristics and co-medication on the occurrence of this adverse effect. Drug prescription data from 1994 to 2011 were retrieved from the IADB.nl database. To study the influence of ICS use on occurrence of oral candidiasis, a prescription symmetry analysis was used, including patients using medication for oral candidiasis up to 1 year before or after ICS initiation. The relative risk was calculated by dividing the number of patients receiving medication for oral candidiasis after ICS initiation by the number of patients receiving the same medication before ICS initiation. Sub-analyses were conducted to compare the relative risks at several time points after ICS initiation and to account for therapy persistence by only including chronic users of ICS. A multivariate logistic regression model was used to identify predictive factors. A total of 52,279 incident users of ICS therapy were identified, of which 1,081 received medication for oral candidiasis up to 1 year before or after ICS initiation. A total of 701 patients received medication for oral candidiasis after ICS initiation, while 361 received these medications in the reversed sequence, resulting in a sequence ratio (SR) of 1.94 (95 % CI 1.71-2.21). In the first 3 months after ICS initiation, the SR was 2.72 (95 % CI 2.19-3.38) and then decreased to 1.47 (95 % CI 1.11-1.95) 9-12 months after ICS initiation. Predictive factors were higher daily dose of ICS and concomitant use of oral corticosteroids. This study found a significant and clinically relevant increased number of patients receiving medication for oral candidiasis in the first year after therapy initiation with ICS. Relative risk is highest in the first 3 months, but remains increased up to at least 1 year after ICS initiation. This study stresses the need for patient education and inhalation instruction.
Impact of topographic mask models on scanner matching solutions
NASA Astrophysics Data System (ADS)
Tyminski, Jacek K.; Pomplun, Jan; Renwick, Stephen P.
2014-03-01
Of keen interest to the IC industry are advanced computational lithography applications such as Optical Proximity Correction of IC layouts (OPC), scanner matching by optical proximity effect matching (OPEM), and Source Optimization (SO) and Source-Mask Optimization (SMO) used as advanced reticle enhancement techniques. The success of these tasks is strongly dependent on the integrity of the lithographic simulators used in computational lithography (CL) optimizers. Lithographic mask models used by these simulators are key drivers impacting the accuracy of the image predications, and as a consequence, determine the validity of these CL solutions. Much of the CL work involves Kirchhoff mask models, a.k.a. thin masks approximation, simplifying the treatment of the mask near-field images. On the other hand, imaging models for hyper-NA scanner require that the interactions of the illumination fields with the mask topography be rigorously accounted for, by numerically solving Maxwell's Equations. The simulators used to predict the image formation in the hyper-NA scanners must rigorously treat the masks topography and its interaction with the scanner illuminators. Such imaging models come at a high computational cost and pose challenging accuracy vs. compute time tradeoffs. Additional complication comes from the fact that the performance metrics used in computational lithography tasks show highly non-linear response to the optimization parameters. Finally, the number of patterns used for tasks such as OPC, OPEM, SO, or SMO range from tens to hundreds. These requirements determine the complexity and the workload of the lithography optimization tasks. The tools to build rigorous imaging optimizers based on first-principles governing imaging in scanners are available, but the quantifiable benefits they might provide are not very well understood. To quantify the performance of OPE matching solutions, we have compared the results of various imaging optimization trials obtained with Kirchhoff mask models to those obtained with rigorous models involving solutions of Maxwell's Equations. In both sets of trials, we used sets of large numbers of patterns, with specifications representative of CL tasks commonly encountered in hyper-NA imaging. In this report we present OPEM solutions based on various mask models and discuss the models' impact on hyper- NA scanner matching accuracy. We draw conclusions on the accuracy of results obtained with thin mask models vs. the topographic OPEM solutions. We present various examples representative of the scanner image matching for patterns representative of the current generation of IC designs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, Roger A; Melin, Alexander M; Burress, Timothy A
The overall project objective is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant components. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration vehicle. The project s focus is not primarily on pump design, but instead is on methods to deeply embed I&C within a pump system. However, because the I&C is intimately part of the basic millisecond-by-millisecond functioning of the pump, the I&C design cannot proceed in isolation from the other aspects of the pump. The pumpmore » will not function if the characteristics of the I&C are not embedded within the design because the I&C enables performance of the basic function rather than merely monitoring quasi-stable performance. Traditionally, I&C has been incorporated in nuclear power plant (NPP) components after their design is nearly complete; adequate performance was obtained through over-design. This report describes the progress and status of the project and provides a conceptual design overview for the embedded I&C pump.« less
NASA Astrophysics Data System (ADS)
Fuchs, Erica R. H.; Bruce, E. J.; Ram, R. J.; Kirchain, Randolph E.
2006-08-01
The monolithic integration of components holds promise to increase network functionality and reduce packaging expense. Integration also drives down yield due to manufacturing complexity and the compounding of failures across devices. Consensus is lacking on the economically preferred extent of integration. Previous studies on the cost feasibility of integration have used high-level estimation methods. This study instead focuses on accurate-to-industry detail, basing a process-based cost model of device manufacture on data collected from 20 firms across the optoelectronics supply chain. The model presented allows for the definition of process organization, including testing, as well as processing conditions, operational characteristics, and level of automation at each step. This study focuses on the cost implications of integration of a 1550-nm DFB laser with an electroabsorptive modulator on an InP platform. Results show the monolithically integrated design to be more cost competitive over discrete component options regardless of production scale. Dominant cost drivers are packaging, testing, and assembly. Leveraging the technical detail underlying model projections, component alignment, bonding, and metal-organic chemical vapor deposition (MOCVD) are identified as processes where technical improvements are most critical to lowering costs. Such results should encourage exploration of the cost advantages of further integration and focus cost-driven technology development.
The use of sports references in marketing of food and beverage products in supermarkets.
Bragg, Marie A; Liu, Peggy J; Roberto, Christina A; Sarda, Vishnu; Harris, Jennifer L; Brownell, Kelly D
2013-04-01
Food marketing has been identified as a significant driver of the childhood obesity epidemic. The purpose of the present study was to (i) conduct a content analysis of the types of sports references that appear on supermarket food and beverage products and (ii) assess each product's nutritional and marketing profile. This was a descriptive study. Every product featuring sports references on the packaging was purchased in two major supermarkets during 2010. A content analysis was conducted and nutritional evaluations were made based on the Nutrient Profile Model, a validated nutrition model. Marketing data were obtained from The Nielsen Company. Two major supermarkets in Connecticut, USA. Food and beverage products (n 102) were selected from two supermarkets. The 102 products (fifty-three foods and forty-nine beverages) had sports references as part of their packaging: 72·5 % featured a character exercising, 42·2 % were endorsed by a professional sports entity and 34·0 % were child-targeted. The median nutrition score for food products was 36 (1 = unhealthiest and 100 = healthiest; scores of ≥63 are considered healthy according to this model). More than two-thirds of beverages (69·4 %) were 100 % sugar-sweetened. Children saw significantly more commercials for these products than adults. Companies place sports figures on food and beverage products that are child-targeted and unhealthy.
Advanced induction accelerator designs for ground based and space based FELs
NASA Astrophysics Data System (ADS)
Birx, Daniel
1994-04-01
The primary goal of this program was to improve the performance of induction accelerators with particular regards to their being used to drive Free Electron Lasers (FEL's). It is hoped that FEL's operating at visible wavelengths might someday be used to beam power from earth to extraterrestrial locations. One application of this technology might be strategic theater defense, but this power source might be used to propel vehicles or supplement solar energized systems. Our path toward achieving this goal was directed first toward optimization of the nonlinear magnetic material used in induction accelerator construction and secondly at the overall design in terms of cost, size and efficiency. We began this research effort with an in depth study into the properties of various nonlinear magnetic materials. With the data on nonlinear magnetic materials, so important to the optimization of efficiency, in hand, we envisioned a new induction accelerator design where all of the components were packaged together in one container. This induction accelerator module would combine an /ll-solid-state, nonlinear magnetic driver and the induction accelerator cells all in one convenient package. Each accelerator module (denoted SNOMAD-IVB) would produce 1.0 MeV of acceleration with the exception of the SNOMAD-IV injector module which would produce 0.5 MeV of acceleration for an electron beam current up to 1000 amperes.
Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.
Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu
2017-11-01
A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.
Crowther, Robert G; Leicht, Anthony S; Spinks, Warwick L; Sangla, Kunwarjit; Quigley, Frank; Golledge, Jonathan
2012-01-01
The purpose of this study was to examine the effects of a 6-month exercise program on submaximal walking economy in individuals with peripheral arterial disease and intermittent claudication (PAD-IC). Participants (n = 16) were randomly allocated to either a control PAD-IC group (CPAD-IC, n = 6) which received standard medical therapy, or a treatment PAD-IC group (TPAD-IC; n = 10) which took part in a supervised exercise program. During a graded treadmill test, physiological responses, including oxygen consumption, were assessed to calculate walking economy during submaximal and maximal walking performance. Differences between groups at baseline and post-intervention were analyzed via Kruskal-Wallis tests. At baseline, CPAD-IC and TPAD-IC groups demonstrated similar walking performance and physiological responses. Postintervention, TPAD-IC patients demonstrated significantly lower oxygen consumption during the graded exercise test, and greater maximal walking performance compared to CPAD-IC. These preliminary results indicate that 6 months of regular exercise improves both submaximal walking economy and maximal walking performance, without significant changes in maximal walking economy. Enhanced walking economy may contribute to physiological efficiency, which in turn may improve walking performance as demonstrated by PAD-IC patients following regular exercise programs.
VanderWaal, Kristyn E.; Yamamoto, Ryosuke; Wakabayashi, Ken-ichi; Fox, Laura; Kamiya, Ritsu; Dutcher, Susan K.; Bayly, Phillip V.; Sale, Winfield S.; Porter, Mary E.
2011-01-01
I1 dynein, or dynein f, is a highly conserved inner arm isoform that plays a key role in the regulation of flagellar motility. To understand how the IC138 IC/LC subcomplex modulates I1 activity, we characterized the molecular lesions and motility phenotypes of several bop5 alleles. bop5-3, bop5-4, and bop5-5 are null alleles, whereas bop5-6 is an intron mutation that reduces IC138 expression. I1 dynein assembles into the axoneme, but the IC138 IC/LC subcomplex is missing. bop5 strains, like other I1 mutants, swim forward with reduced swimming velocities and display an impaired reversal response during photoshock. Unlike mutants lacking the entire I1 dynein, however, bop5 strains exhibit normal phototaxis. bop5 defects are rescued by transformation with the wild-type IC138 gene. Analysis of flagellar waveforms reveals that loss of the IC138 subcomplex reduces shear amplitude, sliding velocities, and the speed of bend propagation in vivo, consistent with the reduction in microtubule sliding velocities observed in vitro. The results indicate that the IC138 IC/LC subcomplex is necessary to generate an efficient waveform for optimal motility, but it is not essential for phototaxis. These findings have significant implications for the mechanisms by which IC/LC complexes regulate dynein motor activity independent of effects on cargo binding or complex stability. PMID:21697502
Baker-Genaw, Kimberly; Kokas, Maria S; Ahsan, Syed F; Darnley-Fisch, Deborah; Drake, Sean; Goyal, Nikhil; Inamdar, Kedar; Moutzouros, Vasilios; Prabhakar, Deepak; Rolland, Laurie; Sangha, Roopina; Shreve, Maria; Woodward, Ann
2016-07-01
Little is known about residents' performance on the milestones at the institutional level. Our institution formed a work group to explore this using an institutional-level curriculum and residents' evaluation of the milestones. We assessed whether beginner-level milestones for interpersonal and communication skills (ICS) related to observable behaviors in ICS-focused objective structured clinical examinations (OSCEs) for postgraduate year (PGY) 1 residents across specialties. The work group compared ICS subcompetencies across 12 programs to identify common beginner-level physician-patient communication milestones. The selected ICS milestone sets were compared for common language with the ICS-OSCE assessment tool-the Kalamazoo Essential Elements of Communication Checklist-Adapted (KEECC-A). To assess whether OSCE scores related to ICS milestone scores, all PGY-1 residents from programs that were part of Next Accreditation System Phase 1 were identified; their OSCE scores from July 2013 to June 2014 and ICS subcompetency scores from December 2014 were compared. The milestones for 10 specialties and the transitional year had at least 1 ICS subcompetency that related to physician-patient communication. The language of the ICS beginner-level milestones appears similar to behaviors outlined in the KEECC-A. All 60 residents with complete data received at least a beginner-level ICS subcompetency score and at least a satisfactory score on all 3 OSCEs. The ICS-OSCE scores for PGY-1 residents appear to relate to beginner-level milestones for physician-patient communication across multiple specialties.
Johnstone, Karen A; DuBose, Amanda J; Futtner, Christopher R; Elmore, Michael D; Brannan, Camilynn I; Resnick, James L
2006-02-01
Prader-Willi syndrome (PWS) and Angelman syndrome (AS) are caused by the loss of imprinted gene expression from chromosome 15q11-q13. Imprinted gene expression in the region is regulated by a bipartite imprinting centre (IC), comprising the PWS-IC and the AS-IC. The PWS-IC is a positive regulatory element required for bidirectional activation of a number of paternally expressed genes. The function of the AS-IC appears to be to suppress PWS-IC function on the maternal chromosome through a methylation imprint acquired during female gametogenesis. Here we have placed the entire mouse locus under the control of a human PWS-IC by targeted replacement of the mouse PWS-IC with the equivalent human region. Paternal inheritance of the human PWS-IC demonstrates for the first time that a positive regulatory element in the PWS-IC has diverged. These mice show postnatal lethality and growth deficiency, phenotypes not previously attributed directly to the affected genes. Following maternal inheritance, the human PWS-IC is able to acquire a methylation imprint in mouse oocytes, suggesting that acquisition of the methylation imprint is conserved. However, the imprint is lost in somatic cells, showing that maintenance has diverged. This maternal imprinting defect results in expression of maternal Ube3a-as and repression of Ube3a in cis, providing evidence that Ube3a is regulated by its antisense and creating the first reported mouse model for AS imprinting defects.
78 FR 4369 - Rates for Interstate Inmate Calling Services
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-22
.... Marginal Location Methodology. In 2008, ICS providers submitted the ICS Provider Proposal for ICS rates. The ICS Provider Proposal uses the ``marginal location'' methodology, previously adopted by the... ``marginal location'' methodology provides a ``basis for rates that represent `fair compensation' as set...
Supramolecular Systems Behavior at the Air-Water Interface. Molecular Dynamic Simulation Study.
NASA Astrophysics Data System (ADS)
Sandoval, C.; Saavedra, M.; Gargallo, L.; Radić, D.
2008-08-01
Atomistic molecular dynamics simulation (MDS) was development to investigate the structural and dynamic properties of a monolayer of supramolecular systems. The simulations were performed at room temperature, on inclusion complexes (ICs) of α-cyclodextrin (CD) with poly(ethylene-oxide)(PEO), poly(ɛ-caprolactone)(PEC) and poly(tetrahydrofuran)(PTHF). The simulations were carried out for a surface area of 30Å. The trajectories of the MDS show that the system more stable was IC-PEC, being the less stable IC-PEO. The disordered monolayer for the systems was proved by the orientation correlation function and the radial distribution function between the polar groups of ICs and the water molecules. We found that the system IC-PEC was more stable that the systems IC-PTHF and IC-PEO.
Designing low cost LED display for the billboard
NASA Astrophysics Data System (ADS)
Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng
2011-10-01
With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.
Cost Analysis of Fluconazole Prophylaxis for Prevention of Neonatal Invasive Candidiasis.
Swanson, Jonathan R; Vergales, Jeff; Kaufman, David A; Sinkin, Robert A
2016-05-01
Fluconazole prophylaxis (FP) in premature infants is well studied and has been shown to decrease invasive candidiasis (ICs). IC in neonates has significant financial costs; determining the cost-benefit of FP may provide additional justification for targeting high-risk neonates. We aimed to determine the IC rate in premature infants at which FP is cost-beneficial. A decision tree cost-analysis model using cost of FP related to costs associated with IC was used. We searched PubMed for all papers that used intravenous FP and reported rates of IC in very low birth weight neonates. Average IC rates in those who received FP (2.0%; range, 0-6.1%) and in those who did not receive FP (9.2%; range, 0-20.5%) were used. Incremental hospital costs because of IC and for FP were retrieved from the literature. Sensitivity analysis was performed to determine the incremental cost of FP across the range of published IC rates. The average cost per patient attributed to IC in patients receiving FP was $785 versus $2617 in those not receiving FP. Sensitivity analysis demonstrates the rate of IC would need to be <2.8% for FP to lose its cost-benefit. In Monte Carlo simulation, targeting infants <1000 g would lead to $50,304,333 in cost savings per year in the United States. FP provides a cost-advantage across most IC rates seen in the youngest premature infants. Using a rate of 2.8% for their individual high-risk neonatal intensive care unit patients, providers can determine if FP is cost-beneficial in determining for whom to provide IC prophylaxis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Modjaz, Maryam; Liu, Yuqian Q.; Bianco, Federica B.
We present the first systematic investigation of spectral properties of 17 Type Ic Supernovae (SNe Ic), 10 broad-lined SNe Ic (SNe Ic-bl) without observed gamma-ray bursts (GRBs), and 11 SNe Ic-bl with GRBs (SN-GRBs) as a function of time in order to probe their explosion conditions and progenitors. Using a number of novel methods, we analyze a total of 407 spectra, which were drawn from published spectra of individual SNe as well as from the densely time-sampled spectra of Modjaz et al (2014). In order to quantify the diversity of the SN spectra as a function of SN subtype, wemore » construct average spectra of SNe Ic, SNe Ic-bl without GRBs, and SNe Ic-bl with GRBs. We find that SN 1994I is not a typical SN Ic, contrasting the general view, while the spectra of SN 1998bw/GRB 980425 are representative of mean spectra of SNe Ic-bl. We measure the ejecta absorption and width velocities using a new method described here and find that SNe Ic-bl with GRBs, on average, have quantifiably higher absorption velocities, as well as broader line widths than SNe without observed GRBs. In addition, we search for correlations between SN-GRB spectral properties and the energies of their accompanying GRBs. Finally, we show that the absence of clear He lines in optical spectra of SNe Ic-bl, and in particular of SN-GRBs, is not due to them being too smeared-out due to the high velocities present in the ejecta. This implies that the progenitor stars of SN-GRBs are probably free of the He-layer, in addition to being H-free, which puts strong constraints on the stellar evolutionary paths needed to produce such SN-GRB progenitors at the observed low metallicities.« less
Ham, Dong Yeub; Choi, Woo Suk; Song, Sang Hoon; Ahn, Young-Joon; Park, Hyoung Keun; Kim, Hyeong Gon
2016-01-01
Purpose The aim of this study was to evaluate the efficacy of a multimedia informed consent (IC) presentation on the understanding and satisfaction of patients who were scheduled to receive 120-W green-light high-performance system photoselective vaporization of the prostate (HPS-PVP). Materials and Methods A multimedia IC (M-IC) presentation for HPS-PVP was developed. Forty men with benign prostatic hyperplasia who were scheduled to undergo HPS-PVP were prospectively randomized to a conventional written IC group (W-IC group, n=20) or the M-IC group (n=20). The allocated IC was obtained by one certified urologist, followed by a 15-question test (maximum score, 15) to evaluate objective understanding, and questionnaires on subjective understanding (range, 0~10) and satisfaction (range, 0~10) using a visual analogue scale. Results Demographic characteristics, including age and the highest level of education, did not significantly differ between the two groups. No significant differences were found in scores reflecting the objective understanding of HPS-PVP (9.9±2.3 vs. 10.6±2.8, p=0.332) or in subjective understanding scores (7.5±2.1 vs. 8.6±1.7, p=0.122); however, the M-IC group showed higher satisfaction scores than the W-IC group (7.4±1.7 vs. 8.4±1.5, p=0.033). After adjusting for age and educational level, the M-IC group still had significantly higher satisfaction scores. Conclusions M-IC did not enhance the objective knowledge of patients regarding this surgical procedure. However, it improved the satisfaction of patients with the IC process itself. PMID:27169129
He, Chun-Hui; Li, Xing; Lin, Jun-Hong; Xiao, Qiang; Yu, Jia-Lu; Liu, Ying-Fen; Jiang, Wen-Hui; Chen, Chen; Deng, Li; Zhou, Jie
2017-12-01
Inhaled corticosteroids (ICSs) for treating asthma are controversial because of their negative effects on the growth of asthmatic children and without clearly defined withdrawal strategy. A 2-year ICS step-down and withdrawal strategy has been developed for asthmatic children receiving 3-year subcutaneous immunotherapy (SCIT). Eleven children were included into the SCIT group and 13 children into the ICS group. ICSs were discontinued when children met the following criteria: requiring only 1 puffper day, with good control, for at least 6 months; having a forced expiratory volume in 1 second (FEV 1 )/forced vital capacity ≥80%; and SCIT discontinued for ≥24 months. The main endpoints were the results of both the childhood asthma control test (C-CAT) and the methacholine bronchial provocation test. In the SCIT group, all the 11 children had ICS discontinued, with one child developed asthma attack after pneumonia and received ICS again after completion of SCIT. In the ICS group, five children discontinued ICS and developed asthma attacks later and received ICS again; the other eight children developed severe symptoms during ICS step-down. Thus, the discontinuation of ICS was only achieved in the SCIT group. The dose of methacholine that caused a decrease of 20% in FEV 1 continued to improve after discontinuation of ICS for the SCIT group and presented better results than the ICS group (P=0.050). After completion of SCIT, the C-CAT had improved significantly after 30 months of treatment compared with the ICS group (P<0.05). In the present study, we developed a 2-year step-down and withdrawal strategy from ICSs strategy for allergic asthma children receiving SCIT; the strategy was efficacious and safe.
Anwary, M A
2015-09-21
Intracranial suppuration (ICS) is a life-threatening condition caused by various disease processes and consisting of brain abscess and extradural and subdural empyema. The major causes have changed over the decades. To the author's knowledge, the incidence of ICS in South Africa (SA) has not been established. To determine the incidence of ICS, overall and according to age and gender, and to identify the source and distribution of ICS. The archive of the radiology departments at Umtata General Hospital and Nelson Mandela Academic Hospital in the Transkei region, Eastern Cape Province, SA, was searched retrospectively for computed tomography (CT) reports of patients diagnosed with ICS. Cases in which the CT images, patients' clinical information and CT reports were available for an uninterrupted period of at least 1 year were included. Five time frames were established, encompassing 8 years of data. The first time frame established an incidence of ICS of 1/100,000/year for the Transkei region. All the time frames were utilised to determine the incidence according to gender and age, and the source and distribution of ICS. The incidence of ICS was higher among males than females, and highest in the age groups 0-10 and 11-20 years. A seasonal variation in the incidence of sinusitis- and meningitis-related ICS was noted. Numbers of cases declined during the last 3 years of the study period. Sinusitis, head trauma, ear infection and meningitis were the major sources of ICS. A pulmonary source was not a major feature. In the last 4 years, trauma became the commonest source of ICS. A steady decline in ear infection- and meningitis-related ICS was noted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera, Fernando, E-mail: oncrhf@humv.e; Galan, Maica; Tabernero, Josep
Purpose: To determine in a Phase II trial whether preoperative irinotecan-cisplatin (IC) followed by concurrent IC therapy and radiotherapy (IC/RT) improved outcome in patients with resectable, locally advanced gastric adenocarcinoma (GC) or esophagogastric junction cancer (EGJC). Patients and Methods: Patients with resectable Stage II-IV, M0 GC or EGJC made up the study population. The primary endpoint was pathologic complete response (pCR). Two courses of IC (irinotecan, 65mg/m{sup 2}; cisplatin, 30mg/m{sup 2} on Days 1 and 8 every 21 days) were given. Patients without progression then received IC/RT, consisting of daily radiotherapy (45Gy) with concurrent IC (irinotecan, 65mg/m{sup 2}; cisplatin, 30mg/m{supmore » 2} on Days 1, 8, 15, and 22). Surgical resection was performed, if feasible, 5-8 weeks after the end of radiotherapy. Results: Twenty-three patients were included in the study: 10 with EGJC and 13 with GC. Two patients (9%) achieved pCR. The incidences of Grade 3-4 toxicities were as follows: IC: neutropenia 35% (febrile 13%), anemia 22%, diarrhea 22%, emesis 8%; IC/RT: neutropenia 52% (febrile 5%), asthenia 19%, anemia 9%, emesis 9%, diarrhea 5%, cardiotoxicity 5%. No patients died during IC or IC/RT. R0 resection was achieved in 15 patients (65%). Median survival was 14.5 months, and the actuarial 2-year survival rate was 35%. Conclusions: Preoperative IC followed by IC/RT resulted in moderate response and resection rates with mild toxicity in patients with GC and EGJC.« less
Rahman, Inayat Ur; Ijaz, Farhana; Afzal, Aftab; Iqbal, Zafar; Ali, Niaz; Khan, Shujaul Mulk
2016-11-04
Ethno medicinal traditional knowledge regarding the uses of indigenous medicinal plants used for various human digestive disorders are mostly known to the elder community members. As the young generation is not much aware about such vital traditional medicinal practice because they rely on elders. To document, accumulate and widely disseminate the massive indigenous knowledge of century's practiced therapeutic uses of medicinal plants by the local people living in this remote area. A total of 63 local inhabitants (39 males and 24 females) were interviewed through a structured questionnaire. The data obtained were quantitatively analyzed through the use value (UV i ), fidelity level index (FL%) and relative frequency citations (RFCs), consensus index (CI%) and informant consensus factor (F IC ). For novel uses all the plants were checked with previously published articles on same disease by analyzing through Jaccard index (JI) and Sorensen's similarity index (QS). Plants specimen were preserved, mounted and labeled on the herbarium sheets, cataloged and deposited with voucher numbers in Hazara University Herbarium, Mansehra, Pakistan (HUP). 44 plant species belonging to 44 genera and 28 families were documented in the current study. These medicinal plant species were used commonly as an ethno medicine against 26 various digestive disorders out of which most frequently occurred are; stomach ache, diarrhea, indigestion, constipation and inflammation etc. Herbaceous plant species were the dominant among plants studied which were 64% of the total plants, followed by trees (20%) and shrubs (16%). Lamiaceae was the leading family among collected medicinal plant species (13.6%). Maximum medicinal plant species were used for treatment of stomach ache (11.7%), diarrhea and indigestion (10.9% each). Most widely used parts were leaves (41% citations), fruit and whole plant (12% citations each) for medication of various digestive problems by the traditional drivers. Dominated medicinal plants with most use values were Ficus carica having (UV i =0.90) and Trifolium repens (UV i =0.84). Based on the RFC values, the most cited medicinal plant species by the traditional drivers were Ficus carica (0.43) and Berberis lycium (0.41), while most respondents percentage was noticed for same plant species calculated through consensus index (CI%=42.9% and 41.3%) respectively. The medicinal plant species with highest fidelity level was of Grewia optiva, Juglans regia and Sorbaria tomentosa each cited 100% for anthelmintic, easy digestion and Diarrhea respectively. Due to representation by only single medicinal plant taxa (Nt=1), the digestive diseases viz. cholera, colon cancer, emetic, internal injuries, kill microorganisms, Soothing, tumor and urine suppression had maximum F IC value. The analytical result reveals that 57% of medicinal plant species were reported for the first time regarding their uses. new medicinal uses of Anaphalis contorta, Caltha palustris, Pinus wallichiana, Plantago himalaica were recorded for the first time from Pakistan and Aralia cachemirica, Bupleurum longicaule, Pleurospermum stellatum, Potentilla argentea and Juglans regia across the globe for currently reported medicinal uses. Besides this, all the mentioned plant species were reported for the first time for digestive disorders from Manoor Valley as no single study up-till now has been conducted ethno medicinally. The present study revealed the importance to document and launch list of all the possible plants that are used in traditional medicinal practices against digestive disorders in the unexplored study area and to show the important medicinal plants for future biological, phytochemical and pharmacological experimentation regarding digestive problems. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Lopes-Virella, Maria F; Baker, Nathaniel L; Hunt, Kelly J; Lyons, Timothy J; Jenkins, Alicia J; Virella, Gabriel
2012-06-01
To determine whether immunocomplexes (ICs) containing advanced glycation end product (AGE)-LDL (AGE-LDL) and oxidized LDL (oxLDL) contribute to the development of retinopathy over a 16-year period in subjects with type 1 diabetes. Levels of AGE-LDL and oxLDL in ICs were measured in 517 patients of the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) cohort. Retinopathy was assessed by stereoscopic fundus photography. Cox proportional hazards models were used to assess the effect of AGE-LDL-ICs and oxLDL-ICs on retinopathy progression. In unadjusted models, higher baseline levels of AGE-LDL-ICs and oxLDL-ICs significantly predicted progression of diabetic retinopathy outcomes. After adjustment by study-design variables (treatment group, retinopathy cohort, duration of type 1 diabetes, and baseline albumin excretion rate [AER], hemoglobin A(1c) (HbA(1c)), and Early Treatment Diabetic Retinopathy Study [ETDRS] score), one SD increase in IC levels was associated with 47% (hazard ratio [HR] 1.47 [95% CI 1.19-1.81]; AGE-LDL-IC) and 45% (1.45 [1.17-1.80]; oxLDL-IC) increased risk of developing proliferative diabetic retinopathy (PDR) and 37% (1.37 [1.12-1.66]; to both ICs) increased risk of progressing to severe nonproliferative retinopathy. Analyses were stratified by retinopathy cohort because results differed between primary and secondary cohorts. For AGE-LDL-ICs, HR for progression to PDR was 2.38 (95% CI 1.30-4.34) in the primary cohort and attenuated in the secondary cohort (1.29 [1.03-1.62]). Similar results were observed for oxLDL-ICs. Increased levels of AGE-LDL and oxLDL in ICs are associated with increased risk for progression to advanced retinopathy in patients with type 1 diabetes, indicating that the antibody response to modified LDL plays a significant role in retinopathy progression.
SU-E-T-547: Rotating Shield Brachytherapy (RSBT) for Cervical Cancer.
Yang, W; Kim, Y; Liu, Y; Wu, X; Flynn, R
2012-06-01
To assess rotating shield brachytherapy (RSBT) delivered with the electronic brachytherapy (eBT) source comparing to intracavitary (IC) and intracavitary plus supplemental interstitial brachytherapy (IC+IS BT) delivered with conventional isotope radiation source. IC, IC+IS and RSBT plan was simulated for 5 patients with advanced cervical cancer (>40cc). One BT plan for each patient (fraction 1) guided by magnetic resonance imaging (MRI) was used in our treatment planning system (TPS). A bio- and MRI-compatible polycarbonate (Makrolon Rx3158) intrauterine applicator was simulated for IC and RSBT, and the vienna applicator was simulated for IC+IS BT. 192Ir was used as the radiation source of IC and IC+IS BT; Xoft AxxentTM eBT source was used for RSBT. A 0.5 mm thick tungsten shield was used for RS-BT with different azimuthal and zenith angles. The total dose for each plan was escalated as the external beam radiation therapy (EBRT) plus BT times fraction number (5 in our case). RSBT and IC+IS BT had higher dose conformity in terms of D90 than IC BT for all the patients. The advantage of RSBT over IC+IS BT was dependent on the shield emission angle, tumor shape and tandem applicator location. The delivery time of RSBT was increased as finer emission angle was selected. RSBT is a less-invasive potential alternative to conventional IC and IC+IS BT for treating bulky (>40cc) cervical cancer. RSBT can provide better treatment outcome with clinically acceptable increased delivery time if proper emission angle is selected based on the tumor shape and tandem applicator location. supported in part by NSF grants CCF-0830402 and CCF-0844765; and the NIH grant K25-CA123112, and American Cancer Society seed grant (IRG-77-004-31). © 2012 American Association of Physicists in Medicine.
Ellens, Harma; Deng, Shibing; Coleman, JoAnn; Bentz, Joe; Taub, Mitchell E.; Ragueneau-Majlessi, Isabelle; Chung, Sophie P.; Herédi-Szabó, Krisztina; Neuhoff, Sibylle; Palm, Johan; Balimane, Praveen; Zhang, Lei; Jamei, Masoud; Hanna, Imad; O’Connor, Michael; Bednarczyk, Dallas; Forsgard, Malin; Chu, Xiaoyan; Funk, Christoph; Guo, Ailan; Hillgren, Kathleen M.; Li, LiBin; Pak, Anne Y.; Perloff, Elke S.; Rajaraman, Ganesh; Salphati, Laurent; Taur, Jan-Shiang; Weitz, Dietmar; Wortelboer, Heleen M.; Xia, Cindy Q.; Xiao, Guangqing; Yamagata, Tetsuo
2013-01-01
In the 2012 Food and Drug Administration (FDA) draft guidance on drug-drug interactions (DDIs), a new molecular entity that inhibits P-glycoprotein (P-gp) may need a clinical DDI study with a P-gp substrate such as digoxin when the maximum concentration of inhibitor at steady state divided by IC50 ([I1]/IC50) is ≥0.1 or concentration of inhibitor based on highest approved dose dissolved in 250 ml divide by IC50 ([I2]/IC50) is ≥10. In this article, refined criteria are presented, determined by receiver operating characteristic analysis, using IC50 values generated by 23 laboratories. P-gp probe substrates were digoxin for polarized cell-lines and N-methyl quinidine or vinblastine for P-gp overexpressed vesicles. Inhibition of probe substrate transport was evaluated using 15 known P-gp inhibitors. Importantly, the criteria derived in this article take into account variability in IC50 values. Moreover, they are statistically derived based on the highest degree of accuracy in predicting true positive and true negative digoxin DDI results. The refined criteria of [I1]/IC50 ≥ 0.03 and [I2]/IC50 ≥ 45 and FDA criteria were applied to a test set of 101 in vitro-in vivo digoxin DDI pairs collated from the literature. The number of false negatives (none predicted but DDI observed) were similar, 10 and 12%, whereas the number of false positives (DDI predicted but not observed) substantially decreased from 51 to 40%, relative to the FDA criteria. On the basis of estimated overall variability in IC50 values, a theoretical 95% confidence interval calculation was developed for single laboratory IC50 values, translating into a range of [I1]/IC50 and [I2]/IC50 values. The extent by which this range falls above the criteria is a measure of risk associated with the decision, attributable to variability in IC50 values. PMID:23620486
Kinai, Ei; Kato, Shingo; Hosokawa, Shinichi; Sadatsuki, Miyuki; Gatanaga, Hiroyuki; Kikuchi, Yoshimi; Lam, Nguyen Van; Ha, Do Quan; Kinh, Nguyen Van; Liem, Nguyen Thanh; Oka, Shinichi
2016-07-01
Zidovudine (AZT) is mainly used to prevent mother-to-child HIV-1 transmission (PMTCT). Despite serious concerns on AZT-associated toxicity, there is little information on pharmacokinetics of intracellular AZT metabolites in infants. We conducted a prospective study in 31 HIV-uninfected infants who received AZT for PMTCT. Blood samples were obtained from 14 infants on postdelivery days (PDD) 1, 7, 14, and 28 and from 17 infants at 0 and 4 hours after dosing on PDD-1. Plasma AZT concentrations (pAZT) and intracellular concentrations of AZT-monophosphate (icAZT-MP), diphosphate (icAZT-DP), and triphosphate (icAZT-TP) were determined. Plasma AZT and icAZT-MP concentrations were 2713 nmol/L and 79 fmol/10 cells in PDD-1, but decreased to 1437 nmol/L and 31 fmol/10 cells by PDD-28 (P = 0.02 and P = 0.07 for all PDDs, respectively), whereas those of icAZT-DP and icAZT-TP remained low throughout the sampling period (P = 0.29 and P = 0.61 for all PDDs, respectively) There were no differences in icAZT-TP between infants of the 2 mg/kg 4 times a day dose and 4 mg/kg twice daily dose (P = 0.25), whereas pAZT and icAZT-MP levels were higher in the latter (P < 0.01 and <0.01, respectively). The pAZT and icAZT-MP significantly increased from 0 to 4 hours after dosing (P < 0.001 and <0.001, respectively), whereas icAZT-DP, icAZT-TP levels were not changed (P = 0.41 and 0.33, respectively). The level of icAZT-TP did not change with age, time, or a single dose despite the wide range of pAZT concentration. A safer dosage needs to be determined because high pAZT levels do not parallel those of icAZT-TP.
A Longitudinal Analysis of Anger and Inhibitory Control in Twins from 12–36 Months of Age
Goldsmith, H. Hill
2010-01-01
Inhibitory control (IC) is a dimension of child temperament that involves the self-regulation of behavioral responses under some form of instruction or expectation. Although IC is posited to appear in toddlerhood, the voluntary control of emotions such as anger begins earlier. Little research has analyzed relations between emotional development in infancy and later emerging IC. We examined phenotypic associations and genetic and environmental influences on parent-and laboratory-assessed anger and IC in a twin sample from 12 to 36 months of age. Typically, twins with low levels of IC had high levels of anger. Behavioral genetic findings confirmed significant genetic influences on anger and IC as assessed by parents, and on lab-based anger assessments. Shared environmental factors contributed to twin similarity on lab-assessed anger and IC at 36 months. Phenotypic covariance between anger and IC was largely due to overlapping genetic factors for parent ratings, and environmental factors in the laboratory. PMID:21159093
Giuliano, Ryan J; Roos, Leslie E; Farrar, Jessica D; Skowron, Elizabeth A
2018-04-01
A child's cumulative risk for early exposure to stress has been linked to alterations of self-regulation outcomes, including neurobiological correlates of inhibitory control (IC). We examined whether children's ability to engage the parasympathetic nervous system impacts how risk affects IC. Children ages 3-5 years completed two laboratory measures of IC while respiratory sinus arrhythmia (RSA) was measured, indexing parasympathetic activity. Children with greater risk demonstrated lower IC; risk also moderated associations between RSA reactivity and IC. For children with less risk, greater RSA withdrawal during IC tasks was associated with better IC. In contrast, greater risk was associated with poor IC, regardless of RSA withdrawal. Effects of risk were more pronounced for cumulative than individual measures. Results suggest that cumulative risk exposure disrupts connectivity between physiological and behavioral components of self-regulation in early childhood. Parasympathetic withdrawal to cognitive tasks may be less relevant for performance in developmental samples experiencing greater life stress. © 2018 Wiley Periodicals, Inc.
The effects of iris-ciliary complex on the organ cultured rabbit ocular lens.
Niyogi, T K; Emanuel, K; Parafina, J; Bagchi, M
1991-01-01
Freshly isolated rabbit lenses were cultured with and without attached iris-ciliary (IC)-complex for 24 hours in TC-199 medium. Subsequent morphological analysis revealed that the IC-complex cannot be maintained in serum-free medium. In addition an observed effect of the IC-complex on the co-cultured lenses could not be due only because of the cellular degeneration of the IC-complex. To test this possibility lenses with attached IC-complexes were incubated in 20% serum-containing TC-199 medium. The IC-complex cultured in 20% serum containing medium retained its normal morphology. However co-cultured lens cells displayed vacuoles and other signs of degeneration. The protein synthetic and Na+/K+ pump activities of these lenses were also significantly depressed. These data indicated that the observed effects of IC-complex on the lens were not due to its cellular degradation. Preliminary experiments showed that the IC-complex contains water soluble factor(s) which could effectively inhibit lens protein synthesis and Na+/K+ pump.
Weil, Brian R.; Suzuki, Gen; Leiker, Merced M.; Fallavollita, James A.; Canty, John M.
2015-01-01
Rationale Allogeneic bone marrow-derived mesenchymal stem cells (MSCs) and cardiosphere-derived cells (CDCs) have each entered clinical trials but a direct comparison of these cell types has not been performed in a large animal model of hibernating myocardium. Objective Using completely blinded methodology, compare the efficacy of global intracoronary allogeneic MSCs (icMSCs, ~35×106) and CDCs (icCDCs, ~35×106) vs. vehicle in cyclosporine-immunosuppressed swine with a chronic LAD stenosis (n=26). Methods and Results Studies began 3-months after instrumentation when wall-thickening (%WT) was reduced (LAD%WT 38±11% (mean ± SD) vs. 83±26% in remote, p<0.01) and similar among groups. Four-weeks after treatment, LAD%WT increased similarly following icCDCs and icMSCs, while it remained depressed in vehicle-treated controls (icMSCs: 51±13%; icCDCs: 51±17%; vehicle: 34±3%, treatments p<0.05 vs. vehicle). There was no change in myocardial perfusion. Both icMSCs and icCDCs increased LAD myocyte nuclear density (icMSCs: 1601±279 nuclei/mm2, icCDCs: 1569±294 nuclei/mm2, vehicle: 973±181 nuclei/mm2, treatments p<0.05 vs. vehicle) and reduced myocyte diameter (icMSCs: 16.4±1.5 μm, icCDCs: 16.8±1.2 μm, vehicle: 20.2±3.7 μm, treatments p<0.05 vs. vehicle) to the same extent. Similar changes in myocyte nuclear density and diameter were observed in the remote region of cell-treated animals. Cell fate analysis using Y-FISH demonstrated rare cells from sex-mismatched donors. Conclusions Allogeneic icMSCs and icCDCs exhibit comparable therapeutic efficacy in a large animal model of hibernating myocardium. Both cell types produced equivalent increases in regional function and stimulated myocyte regeneration in ischemic and remote myocardium. The activation of endogenous myocyte proliferation and regression of myocyte cellular hypertrophy support a common mechanism of cardiac repair. PMID:26271689
NASA Astrophysics Data System (ADS)
Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.
2017-12-01
The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community's requests for changes and improvements.
Yin, Ming; Li, Hao; Bull, Christopher; Borton, David A; Aceros, Juan; Larson, Lawrence; Nurmikko, Arto V
2013-01-01
In this paper we present a new type of head-mounted wireless neural recording device in a highly compact package, dedicated for untethered laboratory animal research and designed for future mobile human clinical use. The device, which takes its input from an array of intracortical microelectrode arrays (MEA) has ninety-seven broadband parallel neural recording channels and was integrated on to two custom designed printed circuit boards. These house several low power, custom integrated circuits, including a preamplifier ASIC, a controller ASIC, plus two SAR ADCs, a 3-axis accelerometer, a 48MHz clock source, and a Manchester encoder. Another ultralow power RF chip supports an OOK transmitter with the center frequency tunable from 3GHz to 4GHz, mounted on a separate low loss dielectric board together with a 3V LDO, with output fed to a UWB chip antenna. The IC boards were interconnected and packaged in a polyether ether ketone (PEEK) enclosure which is compatible with both animal and human use (e.g. sterilizable). The entire system consumes 17mA from a 1.2Ahr 3.6V Li-SOCl2 1/2AA battery, which operates the device for more than 2 days. The overall system includes a custom RF receiver electronics which are designed to directly interface with any number of commercial (or custom) neural signal processors for multi-channel broadband neural recording. Bench-top measurements and in vivo testing of the device in rhesus macaques are presented to demonstrate the performance of the wireless neural interface.
Synthesis and β-glucuronidase inhibitory potential of benzimidazole derivatives.
Khan, Khalid Mohammed; Khan, Momin; Ambreen, Nida; Rahim, Fazal; Naureen, Shagufta; Perveen, Shahnaz; Choudhary, M Iqbal; Voelter, Wolfgang
2012-05-01
Benzimidazole derivatives 1-24 have been synthesized and their in vitro β-glucuronidase inhibitory activitiy was evaluated. Compounds 15 (IC50=6.33+/-0.40 μM), 7 (IC50=22.0+/-0.33 μM), 2 (IC50=23.1+/-1.78 μM), 17 (IC50=23.9+/-1.46 μM), and 3 (IC50=33.8+/-1.61 μM) showed more potent β-glucuronidase inhibitory activity than the standard (D-saccharic acid 1,4 lactone, IC50=48.4+/-1.25 μM). This study has identified a new series of potential β-glucuronidase inhibitors. A structure-activity relationship has also been studied.
The Fabric for Frontier Experiments Project at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, Michael
2014-01-01
The FabrIc for Frontier Experiments (FIFE) project is a new, far-reaching initiative within the Fermilab Scientific Computing Division to drive the future of computing services for experiments at FNAL and elsewhere. It is a collaborative effort between computing professionals and experiment scientists to produce an end-to-end, fully integrated set of services for computing on the grid and clouds, managing data, accessing databases, and collaborating within experiments. FIFE includes 1) easy to use job submission services for processing physics tasks on the Open Science Grid and elsewhere, 2) an extensive data management system for managing local and remote caches, cataloging, querying,more » moving, and tracking the use of data, 3) custom and generic database applications for calibrations, beam information, and other purposes, 4) collaboration tools including an electronic log book, speakers bureau database, and experiment membership database. All of these aspects will be discussed in detail. FIFE sets the direction of computing at Fermilab experiments now and in the future, and therefore is a major driver in the design of computing services worldwide.« less
Bhoopathi, Praveen; Quinn, Bridget A.; Gui, Qin; Shen, Xue-Ning; Grossman, Steven R.; Das, Swadesh K.; Sarkar, Devanand; Fisher, Paul B.; Emdad, Luni
2014-01-01
Polyinosine-polycytidylic acid (pIC) is a synthetic dsRNA that acts as an immune agonist of TLR3 and RLR to activate dendritic and NK cells that can kill tumor cells. pIC can also trigger apoptosis in pancreatic ductal adenocarcinoma cells but its mechanism of action is obscure. In this study, we investigated the potential therapeutic activity of a formulation of pIC with polyethylenimine ([pIC]PEI) in PDAC and investigated its mechanism of action. [pIC]PEI stimulated apoptosis in PDAC cells without affecting normal pancreatic epithelial cells. Mechanistically, [pIC]PEI repressed XIAP and survivin expression and activated an immune response by inducing MDA-5, RIG-I and NOXA. Phosphorylation of AKT was inhibited by [pIC]PEI in PDAC and this event was critical for stimulating apoptosis through XIAP and survivin degradation. In vivo administration of [pIC]PEI inhibited tumor growth via AKT-mediated XIAP degradation in both subcutaneous and quasi-orthotopic-models of PDAC. Taken together, these results offer a preclinical proof-of-concept for the evaluation of [pIC]PEI as an immunochemotherapy to treat pancreatic cancer. PMID:25205107
Stool-based biomarkers of interstitial cystitis/bladder pain syndrome.
Braundmeier-Fleming, A; Russell, Nathan T; Yang, Wenbin; Nas, Megan Y; Yaggie, Ryan E; Berry, Matthew; Bachrach, Laurie; Flury, Sarah C; Marko, Darlene S; Bushell, Colleen B; Welge, Michael E; White, Bryan A; Schaeffer, Anthony J; Klumpp, David J
2016-05-18
Interstitial cystitis/bladder pain syndrome (IC) is associated with significant morbidity, yet underlying mechanisms and diagnostic biomarkers remain unknown. Pelvic organs exhibit neural crosstalk by convergence of visceral sensory pathways, and rodent studies demonstrate distinct bacterial pain phenotypes, suggesting that the microbiome modulates pelvic pain in IC. Stool samples were obtained from female IC patients and healthy controls, and symptom severity was determined by questionnaire. Operational taxonomic units (OTUs) were identified by16S rDNA sequence analysis. Machine learning by Extended Random Forest (ERF) identified OTUs associated with symptom scores. Quantitative PCR of stool DNA with species-specific primer pairs demonstrated significantly reduced levels of E. sinensis, C. aerofaciens, F. prausnitzii, O. splanchnicus, and L. longoviformis in microbiota of IC patients. These species, deficient in IC pelvic pain (DIPP), were further evaluated by Receiver-operator characteristic (ROC) analyses, and DIPP species emerged as potential IC biomarkers. Stool metabolomic studies identified glyceraldehyde as significantly elevated in IC. Metabolomic pathway analysis identified lipid pathways, consistent with predicted metagenome functionality. Together, these findings suggest that DIPP species and metabolites may serve as candidates for novel IC biomarkers in stool. Functional changes in the IC microbiome may also serve as therapeutic targets for treating chronic pelvic pain.
Reyes, Alessandra; Ferreira, Gisele E; Santos, Joyce; Mendes, Fausto M; Imparato, Jose C P; Braga, Mariana M
2013-03-01
Individual calibration (IC) for caries detection methods based on fluorescence is time-consuming, especially for paediatric dentists, if the calibration has to be performed tooth-by-tooth. However, it is not clear how this calibration actually interfere in laser fluorescence (LF) readings. This in vivo study was to verify the influence of different modes of IC on laser fluorescence (LF) readings. Ninety six occlusal and 95 buccal surfaces of 1st permanent molars were examined using LF device after IC performed on control (no IC), the examined teeth, a permanent incisor, a 1st primary molar or a 2nd primary molar. All modes of IC were performed in the same child. Wilcoxon test and Bland-Altman analysis were used to compare the readings. Intraclass correlation coefficients (ICC) were calculated. Laser fluorescence readings without prior calibration were higher than readings performed after any mode of IC and resulted in different values of ICC. After other IC modes, the LF readings were statistically similar. The absence of IC influences LF readings and LF reproducibility, but different IC methods can be considered in clinical practice. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.
Li, Cui; Zhang, Yaoyao; Eremin, Sergei A; Yakup, Omar; Yao, Gang; Zhang, Xiaoying
2017-07-15
Our aim in this study is to show that IgY antibody based immunoassays could be used to detect antibiotic residues in animal-derived food. Briefly, full antigens of gentamicin (Gent) and kanamycin (Kana) were used to immunize the laying chickens to prepare IgY antibodies. Then, these antibodies were evaluated by FPIA and ic-ELISA to detect Gent/Kana in animal-derived samples. The IC 50 of FPIA and ic-ELISA based anti-Gent IgY were 7.70±0.6μg/mL and 0.32±0.06μg/mL, respectively. The IC 50 of FPIA and ic-ELISA based anti-Kana IgY were 7.97±0.9μg/mL and 0.15±0.01μg/mL. The limits of detection (LOD, IC 10 ) for FPIA based anti-Gent/Kana IgY were 0.17 and 0.007μg/mL, respectively. The LOD for ic-ELISA were both 0.001μg/mL. These results indicated that the ic-ELISA might more suitable for antibiotic residues detection than FPIA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Method and apparatus to debug an integrated circuit chip via synchronous clock stop and scan
Bellofatto, Ralph E [Ridgefield, CT; Ellavsky, Matthew R [Rochester, MN; Gara, Alan G [Mount Kisco, NY; Giampapa, Mark E [Irvington, NY; Gooding, Thomas M [Rochester, MN; Haring, Rudolf A [Cortlandt Manor, NY; Hehenberger, Lance G [Leander, TX; Ohmacht, Martin [Yorktown Heights, NY
2012-03-20
An apparatus and method for evaluating a state of an electronic or integrated circuit (IC), each IC including one or more processor elements for controlling operations of IC sub-units, and each the IC supporting multiple frequency clock domains. The method comprises: generating a synchronized set of enable signals in correspondence with one or more IC sub-units for starting operation of one or more IC sub-units according to a determined timing configuration; counting, in response to one signal of the synchronized set of enable signals, a number of main processor IC clock cycles; and, upon attaining a desired clock cycle number, generating a stop signal for each unique frequency clock domain to synchronously stop a functional clock for each respective frequency clock domain; and, upon synchronously stopping all on-chip functional clocks on all frequency clock domains in a deterministic fashion, scanning out data values at a desired IC chip state. The apparatus and methodology enables construction of a cycle-by-cycle view of any part of the state of a running IC chip, using a combination of on-chip circuitry and software.
Abousaad, S; Lassiter, K; Piekarski, A; Chary, P; Striplin, K; Christensen, K; Bielke, L R; Hargis, B M; Dridi, S; Bottje, W G
2017-05-01
Studies were conducted using a commercial InovojectTM system to determine effects of in ovo feeding of dextrin and iodinated casein (IC) on hatch and posthatch growth in broilers. At ∼18.5 d embryonic development, eggs were treated with 0, 240, or 480 μg IC/mL in saline (Cont, IC240, and IC480) or dextrin (Dext, DextIC240 and DextIC480). The Dext solution consisted of 18% maltodextrin and 10% potato starch dextrin; saline was the vehicle used by the company for in ovo vaccination. The volume for all in ovo treatments was 50 μL/injection. Eggs in Experiment 1 were transferred to a commercial hatcher unit whereas eggs in Experiments 2 and 3 were transferred to a research hatcher unit to assess effects of treatments on timing of hatch. At hatch, chicks were randomly selected and placed in floor pens and grown to 6 wk. In Experiment 1, there were no differences in hatch weights, but broilers provided Dext IC240 in ovo were heavier (P < 0.05) at 6 wk compared to other treatments with the exception of the Dext IC240 group. In Experiment 2, hatch weights were heavier (P < 0.05) in chicks receiving IC240 and DexIC480 treatments compared to Controls. At 6 wk, broilers in all treatments were heavier (P < 0.05) than Cont with the exception of IC480. In Experiment 3, hatch was stimulated by IC240 (in saline), but was delayed by Dext IC240. Serum analysis of β-hydroxybutyrate (μM/mL), as an indicator of ketone accumulation from fat metabolism of chicks held in chick boxes for 24 h posthatch (to simulate delay in placement after hatch), indicated that chicks in the IC240 group (that hatched earlier) had higher blood ketones compared to chicks that received Dext or DextIC240 in ovo (that hatched later). We conclude dextrin and iodinated casein (240 μg/mL) provided in ovo (∼18.5 d of embryonic development) has the potential to improve chick quality and posthatch body weight by delaying or narrowing hatch window. © 2016 Poultry Science Association Inc.
Godfrey, Catherine; Tauscher, Gail; Hunsberger, Sally; Austin, Melissa; Scott, Lesley; Schouten, Jeffrey T; Luetkemeyer, Anne F; Benson, Constance; Coombs, Robert; Swindells, Susan
2016-06-10
Health care associated transmission of Mycobacterium tuberculosis (TB) is well described. A previous survey of infection control (IC) practices at clinical research sites in low and middle income countries (LMIC) funded by the National Institute of Allergy and Infectious Diseases (NIAID) conducting HIV research identified issues with respiratory IC practices. A guideline for TB IC based on international recommendations was developed and promulgated. This paper reports on adherence to the guideline at sites conducting or planning to conduct TB studies with the intention of supporting improvement. A survey was developed that assessed IC activities in three domains: facility level measures, administrative control measures and environmental measures. An external site monitor visited each site in 2013-2014, to complete the audit. A central review committee evaluated the site-level survey and results were tabulated. Fisher's exact test was performed to determine whether there were significant differences in practices at sites that had IC officers versus sites that did not have IC officers. Significance was assessed at p=.05 RESULTS: Seven of thirty-three sites surveyed (22 %) had all the evaluated tuberculosis IC (TB IC) elements in place. Sixty-one percent of sites had an IC officer tasked with developing and maintaining TB IC standard operating procedures. Twenty-two (71 %) sites promptly identified and segregated individuals with TB symptoms. Thirty (93 %) sites had a separate waiting area for patients, and 26 (81 %) collected sputum within a specific well-ventilated area that was separate from the general waiting area. Sites with an IC officer were more likely to have standard operating procedures covering TB IC practices (p = 0.02) and monitor those policies (p = 0.02) and perform regular surveillance of healthcare workers (p = 0.02). The presence of an IC officer had a positive impact on performance in most of the TB IC domains surveyed including having adequate ventilation (p = 0.02) and a separate area for sputum collection (p = 0.02) CONCLUSIONS: Specific and targeted support of TB IC activities in the clinical research environment is needed and is likely to have a positive and sustained impact on preventing the transmission of TB to both health care workers and vulnerable HIV-infected research participants.
On the utility of antiprotons as drivers for inertial confinement fusion
NASA Astrophysics Data System (ADS)
Perkins, L. John; Orth, Charles D.; Tabak, Max
2004-10-01
In contrast to the large mass, complexity and recirculating power of conventional drivers for inertial confinement fusion (ICF), antiproton annihilation offers a specific energy of 90 MJ µg-1 and thus a unique form of energy packaging and delivery. In principle, antiproton drivers could provide a profound reduction in system mass for advanced space propulsion by ICF. We examine the physics underlying the use of antiprotons ( \\bar{p} ) to drive various classes of high-yield ICF targets by the methods of volumetric ignition, hotspot ignition and fast ignition. The useable fraction of annihilation deposition energy is determined for both \\bar{p} -driven ablative compression and \\bar{p} -driven fast ignition, in association with zero- and one-dimensional target burn models. Thereby, we deduce scaling laws for the number of injected antiprotons required per capsule, together with timing and focal spot requirements. The kinetic energy of the injected antiproton beam required to penetrate to the desired annihilation point is always small relative to the deposited annihilation energy. We show that heavy metal seeding of the fuel and/or ablator is required to optimize local deposition of annihilation energy and determine that a minimum of ~3 × 1015 injected antiprotons will be required to achieve high yield (several hundred megajoules) in any target configuration. Target gains—i.e. fusion yields divided by the available p- \\bar{p} annihilation energy from the injected antiprotons ( 1.88\\,GeV/\\bar{p} )—range from ~3 for volumetric ignition targets to ~600 for fast ignition targets. Antiproton-driven ICF is a speculative concept, and the handling of antiprotons and their required injection precision—temporally and spatially—will present significant technical challenges. The storage and manipulation of low-energy antiprotons, particularly in the form of antihydrogen, is a science in its infancy and a large scale-up of antiproton production over present supply methods would be required to embark on a serious R&D programme for this application.
Fung, Vicki; Tager, Ira B; Brand, Richard; Newhouse, Joseph P; Hsu, John
2008-01-01
Background Patients face increasing insurance restrictions on prescription drugs, including generic-only coverage. There are no generic inhaled corticosteroids (ICS), which are a mainstay of asthma therapy, and patients pay the full price for these drugs under generic-only policies. We examined changes in ICS use following the introduction of generic-only coverage in a Medicare Advantage population from 2003–2004. Methods Subjects were age 65+, with asthma, prior ICS use, and no chronic obstructive pulmonary disorder (n = 1,802). In 2004, 74.0% switched from having a $30 brand-copayment plan to a generic-only coverage plan (restricted coverage); 26% had $15–25 brand copayments in 2003–2004 (unrestricted coverage). Using linear difference-in-difference models, we examined annual changes in ICS use (measured by days-of-supply dispensed). There was a lower-cost ICS available within the study setting and we also examined changes in drug choice (higher- vs. lower-cost ICS). In multivariable models we adjusted for socio-demographic, clinical, and asthma characteristics. Results In 2003 subjects had an average of 188 days of ICS supply. Restricted compared with unrestricted coverage was associated with reductions in ICS use from 2003–2004 (-15.5 days-of-supply, 95% confidence interval (CI): -25.0 to -6.0). Among patients using higher-cost ICS drugs in 2003 (n = 662), more restricted versus unrestricted coverage subjects switched to the lower-cost ICS in 2004 (39.8% vs. 10.3%). Restricted coverage was not associated with decreased ICS use (2003–2004) among patients who switched to the lower-cost ICS (18.7 days-of-supply, CI: -27.5 to 65.0), but was among patients who did not switch (-38.6 days-of-supply, CI: -57.0 to -20.3). In addition, restricted coverage was associated with decreases in ICS use among patients with both higher- and lower-risk asthma (-15.0 days-of-supply, CI: -41.4 to 11.44; and -15.6 days-of-supply, CI: -25.8 to -5.3, respectively). Conclusion In this elderly population, patients reduced their already low ICS use in response to losing drug coverage. Switching to the lower-cost ICS mitigated reductions in use among patients who previously used higher-cost drugs. Additional work is needed to assess barriers to switching ICS drugs and the clinical effects of these drug use changes. PMID:18638405
Navarrete, Bernardino Alcázar; Palacios, Pedro José Romero; Aguilar-Salvatierra, Antonio; Guardia, Javier; Gómez-Moreno, Gerardo
2015-09-01
To date, no evidence exists in the literature as to the effects of inhaled corticosteroids (ICs) on salivary composition in patients with bronchial asthma. The aim of this study was to assess the effect of ICs on salival composition. Adult patients attending an outpatient respiratory clinic who were classified into two groups (controls and patients with bronchial asthma receiving ICs), were recruited in this cross-sectional study. For each participant, data of clinical records, baseline history of asthma, and regular IC dose were recorded. A sample of stimulated saliva was collected and processed for investigation of mucin 5B (MUC5B), lipoxygenase (LPO), total antioxidant capacity, and 8-hydroxydeoxyguanosine (8-OHdG) levels. Overall, 103 patients (49 controls and 54 patients receiving regular treatment with ICs) were recruited. No differences in comorbidities or smoking habits were observed. Patients treated with high-doses of ICs showed lower levels of salival MUC5B compared with those treated with medium IC doses or those not treated with ICs (1.60 vs. 2.20 vs. 2.53 ng/mL; p = 0.042). In patients with asthma, treatment with high-doses of ICs is associated with reduced levels of salivary MUC5B. This effect can explain some of the effects of ICs on oral health.
Mi, Yashi; Xiao, Chunxia; Du, Qingwei; Wu, Wanqiang; Qi, Guoyuan; Liu, Xuebo
2016-01-01
Momordin Ic is a principal saponin constituent of Fructus Kochiae, which acts as an edible and pharmaceutical product more than 2000 years in China. Our previous research found momordin Ic induced apoptosis by PI3K/Akt and MAPK signaling pathways in HepG2 cells. While the role of autophagy in momordin Ic induced cell death has not been discussed, and the connection between the apoptosis and autophagy is not clear yet. In this work, we reported momordin Ic promoted the formation of autophagic vacuole and expression of Beclin 1 and LC-3 in a dose- and time-dependent manner. Compared with momordin Ic treatment alone, the autophagy inhibitor 3-methyladenine (3-MA) also can inhibit apoptosis, while autophagy activator rapamycin (RAP) has the opposite effect, and the apoptosis inhibitor ZVAD-fmk also inhibited autophagy induced by momordin Ic. Momordin Ic simultaneously induces autophagy and apoptosis by suppressing the ROS-mediated PI3K/Akt and activating the ROS-related JNK and P38 pathways. Additionally, momordin Ic induces apoptosis by suppressing PI3K/Akt-dependent NF-κB pathways and promotes autophagy by ROS-mediated Erk signaling pathway. Those results suggest that momordin Ic has great potential as a nutritional preventive strategy in cancer therapy. Copyright © 2015 Elsevier Inc. All rights reserved.
Hot topics from the Assemblies.
2015-03-01
INSTEAD: a randomised switch trial of indacaterol versus salmeterol/fluticasone in moderate COPD Authors: Rossi A, van der Molen T, Ricardo del Olmo, et al. Eur Respir J 2014; 44: 6, 1548-1556 SUMMARY: Inhaled corticosteroids (ICS) remain a highly controversial treatment for stable chronic obstructive pulmonary disease (COPD). Data linking high-dose ICS with complications, such as pneumonia and fractures, has necessitated a re-evaluation of their role in COPD management. Guidelines currently suggest ICS for patients with a forced expiratory volume in 1 s (FEV1) <50% predicted (or <60% in some regions) and a history of exacerbations. Nevertheless, it is well known that ICS and combination ICS/long-acting β-agonist (LABA) treatments are commonly used outside these groups. In view of the increasingly recognised dangers of ICS treatment, data demonstrating the safety of discontinuing ICS treatment is welcome.
Kutzner, Florian; Vogel, Tobias; Freytag, Peter; Fiedler, Klaus
2011-01-01
In the present research, we argue for the robustness of illusory correlations (ICs, Hamilton & Gifford, 1976) regarding two boundary conditions suggested in previous research. First, we argue that ICs are maintained under extended experience. Using simulations, we derive conflicting predictions. Whereas noise-based accounts predict ICs to be maintained (Fielder, 2000; Smith, 1991), a prominent account based on discrepancy-reducing feedback learning predicts ICs to disappear (Van Rooy et al., 2003). An experiment involving 320 observations with majority and minority members supports the claim that ICs are maintained. Second, we show that actively using the stereotype to make predictions that are met with reward and punishment does not eliminate the bias. In addition, participants' operant reactions afford a novel online measure of ICs. In sum, our findings highlight the robustness of ICs that can be explained as a result of unbiased but noisy learning.
Gevaert, Thomas; Hutchings, Graham; Everaerts, Wouter; Prenen, Hans; Roskams, Tania; Nilius, Bernd; De Ridder, Dirk
2014-04-01
The KIT receptor is considered as a reliable marker for a subpopulation of interstitial cells (IC), and by persistent neonatal inhibition of KIT we have investigated the role of this receptor in the development of IC-networks in bladder and we have observed the functional consequences of this inhibition. Newborn rat pups were treated daily with the KIT inhibitor imatinib mesylate (IM). After 7 days animals were sacrificed and bladder samples were dissected for morphological and functional studies. Morphological research consisted of immunohistochemistry with IC specific antigens (KIT and vimentin) and electron microscopy. The functional studies were based on isolated bladder strips in organ baths, in which spontaneous bladder contractility and the response to a non-subtype selective muscarinic agonist was evaluated. Suburothelial and intramuscular IC were found and characterized in neonatal rat bladder. IM-treatment induced a significant decrease in numbers of IC based on specific immunohistochemical markers, and electron microscopy revealed evidence of IC cell injury. These morphological alterations were observed on intramuscular IC only and not on IC in the suburothelium. Isolated muscle strips from IM-treated animals had a lower contractile frequency and an altered response to muscarinic agonists. The present study shows the presence of regional subpopulations of IC in neonatal rat bladder, provides evidence for a dependence on KIT of the development of intramuscular IC and supports the hypothesis that a poor development of networks of intramuscular IC might have repercussions on spontaneous and muscarinic-induced bladder contractility. © 2013 Wiley Periodicals, Inc.
Circulating immune complexes contain citrullinated fibrinogen in rheumatoid arthritis
Zhao, Xiaoyan; Okeke, Nwora Lance; Sharpe, Orr; Batliwalla, Franak M; Lee, Annette T; Ho, Peggy P; Tomooka, Beren H; Gregersen, Peter K; Robinson, William H
2008-01-01
Introduction There is increasing evidence that autoantibodies and immune complexes (ICs) contribute to synovitis in rheumatoid arthritis (RA), yet the autoantigens incorporated in ICs in RA remain incompletely characterised. Methods We used the C1q protein to capture ICs from plasma derived from human RA and control patients. Antibodies specific for immunoglobulin were used to detect ICs, and fibrinogen antibodies were used to detect fibrinogen-containing ICs. RA and control plasma were separated by liquid chromatography, and fractions then characterised by ELISA, immunoblotting and mass spectrometry. Immunohistochemical staining was performed on rheumatoid synovial tissue. Results C1q-immunoassays demonstrated increased levels of IgG (p = 0.01) and IgM (p = 0.0002) ICs in plasma derived from RA patients possessing anti-cyclic citrullinated peptide (CCP+) autoantibodies as compared with healthy controls. About one-half of the anti-CCP+ RA possessed circulating ICs containing fibrinogen (p = 0.0004). Fractionation of whole RA plasma revealed citrullinated fibrinogen in the high molecular weight fractions that contained ICs. Positive correlations were observed between fibrinogen-containing ICs and anti-citrullinated fibrinogen autoantibodies, anti-CCP antibody, rheumatoid factor and certain clinical characteristics. Immunohistochemical staining demonstrated co-localisation of fibrinogen, immunoglobulin and complement component C3 in RA pannus tissue. Mass spectrometry analysis of immune complexes immunoprecipitated from RA pannus tissue lysates demonstrated the presence of citrullinated fibrinogen. Conclusion Circulating ICs containing citrullinated fibrinogen are present in one-half of anti-CCP+ RA patients, and these ICs co-localise with C3 in the rheumatoid synovium suggesting that they contribute to synovitis in a subset of RA patients. PMID:18710572
Millar, Anna N; Hughes, Carmel M; Ryan, Cristín
2015-06-02
Intermediate care (IC) describes a range of services targeted at older people, aimed at preventing unnecessary hospitalisation, promoting faster recovery from illness and maximising independence. Older people are at increased risk of medication-related adverse events, but little is known about the provision of medicines management services in IC facilities. This study aimed to describe the current provision of medicines management services in IC facilities in Northern Ireland (NI) and to explore healthcare workers' (HCWs) and patients' views of, and attitudes towards these services and the IC concept. Semi-structured interviews were conducted, recorded, transcribed verbatim and analysed using a constant comparative approach with HCWs and patients from IC facilities in NI. Interviews were conducted with 25 HCWs and 18 patients from 12 IC facilities in NI. Three themes were identified: 'concept and reality', 'setting and supply' and 'responsibility and review'. A mismatch between the concept of IC and the reality was evident. The IC facility setting dictated prescribing responsibilities and the supply of medicines, presenting challenges for HCWs. A lack of a standardised approach to responsibility for the provision of medicines management services including clinical review was identified. Whilst pharmacists were not considered part of the multidisciplinary team, most HCWs recognised a need for their input. Medicines management was not a concern for the majority of IC patients. Medicines management services are not integral to IC and medicine-related challenges are frequently encountered. Integration of pharmacists into the multidisciplinary team could potentially improve medicines management in IC.
Driesenaar, Jeanine A; De Smet, Peter A G M; van Hulten, Rolf; Horne, Rob; Zwikker, Hanneke; van den Bemt, Bart; van Dulmen, Sandra
2016-12-01
To compare pharmacists' and pharmacy technicians' perceptions of patients' beliefs regarding inhaled corticosteroids (ICS) with those of patients and to compare the ICS beliefs of pharmacists and technicians with those of patients with asthma. 1269 community pharmacies were approached to fill out an online questionnaire; 1952 patients were sent a questionnaire by post. Beliefs (i.e., necessity and concerns) regarding ICS were measured using (an adapted version of) the Beliefs about Medicines Questionnaire (BMQ-specific). Pharmacists and technicians were instructed to fill out the BMQ for themselves, and to fill it out in the way they thought most of their patients would complete it. 136 pharmacists, 90 pharmacy technicians and 161 patients with asthma completed the questionnaire. Pharmacists and technicians thought patients had more concerns about ICS than patients themselves reported (p < 0.0001). They also thought that patients had stronger beliefs in their personal need for ICS than patients reported (p < 0.01). Pharmacists reported lower levels of concerns than patients (p < 0.05) and both providers attributed a higher level of necessity to ICS than patients did (p < 0.0001). Pharmacists and technicians overestimate the personal need for treatment as well as the concerns patients with asthma have regarding ICS. They also have, to some extent, stronger positive beliefs about ICS than patients. If pharmacists and technicians expect that patients share their positive views about ICS, they might be less likely to elicit and address patients' doubts and concerns about ICS, which might be relevant for effective ICS treatment and subsequent patient outcomes.
Systematic testing of flood adaptation options in urban areas through simulations
NASA Astrophysics Data System (ADS)
Löwe, Roland; Urich, Christian; Sto. Domingo, Nina; Mark, Ole; Deletic, Ana; Arnbjerg-Nielsen, Karsten
2016-04-01
While models can quantify flood risk in great detail, the results are subject to a number of deep uncertainties. Climate dependent drivers such as sea level and rainfall intensities, population growth and economic development all have a strong influence on future flood risk, but future developments can only be estimated coarsely. In such a situation, robust decision making frameworks call for the systematic evaluation of mitigation measures against ensembles of potential futures. We have coupled the urban development software DAnCE4Water and the 1D-2D hydraulic simulation package MIKE FLOOD to create a framework that allows for such systematic evaluations, considering mitigation measures under a variety of climate futures and urban development scenarios. A wide spectrum of mitigation measures can be considered in this setup, ranging from structural measures such as modifications of the sewer network over local retention of rainwater and the modification of surface flow paths to policy measures such as restrictions on urban development in flood prone areas or master plans that encourage compact development. The setup was tested in a 300 ha residential catchment in Melbourne, Australia. The results clearly demonstrate the importance of considering a range of potential futures in the planning process. For example, local rainwater retention measures strongly reduce flood risk a scenario with moderate increase of rain intensities and moderate urban growth, but their performance strongly varies, yielding very little improvement in situations with pronounced climate change. The systematic testing of adaptation measures further allows for the identification of so-called adaptation tipping points, i.e. levels for the drivers of flood risk where the desired level of flood risk is exceeded despite the implementation of (a combination of) mitigation measures. Assuming a range of development rates for the drivers of flood risk, such tipping points can be translated into anticipated time spans over which a measure will be effective. While the new simulation setup is limited to situations where the planner is able to define realistic ranges for the development of drivers of flood risk, it certainly contributes to an improved consideration of deep uncertainties in the planning process. Future work will particularly focus on the application of the framework in a variety of urban development contexts.
ARCGRAPH SYSTEM - AMES RESEARCH GRAPHICS SYSTEM
NASA Technical Reports Server (NTRS)
Hibbard, E. A.
1994-01-01
Ames Research Graphics System, ARCGRAPH, is a collection of libraries and utilities which assist researchers in generating, manipulating, and visualizing graphical data. In addition, ARCGRAPH defines a metafile format that contains device independent graphical data. This file format is used with various computer graphics manipulation and animation packages at Ames, including SURF (COSMIC Program ARC-12381) and GAS (COSMIC Program ARC-12379). In its full configuration, the ARCGRAPH system consists of a two stage pipeline which may be used to output graphical primitives. Stage one is associated with the graphical primitives (i.e. moves, draws, color, etc.) along with the creation and manipulation of the metafiles. Five distinct data filters make up stage one. They are: 1) PLO which handles all 2D vector primitives, 2) POL which handles all 3D polygonal primitives, 3) RAS which handles all 2D raster primitives, 4) VEC which handles all 3D raster primitives, and 5) PO2 which handles all 2D polygonal primitives. Stage two is associated with the process of displaying graphical primitives on a device. To generate the various graphical primitives, create and reprocess ARCGRAPH metafiles, and access the device drivers in the VDI (Video Device Interface) library, users link their applications to ARCGRAPH's GRAFIX library routines. Both FORTRAN and C language versions of the GRAFIX and VDI libraries exist for enhanced portability within these respective programming environments. The ARCGRAPH libraries were developed on a VAX running VMS. Minor documented modification of various routines, however, allows the system to run on the following computers: Cray X-MP running COS (no C version); Cray 2 running UNICOS; DEC VAX running BSD 4.3 UNIX, or Ultrix; SGI IRIS Turbo running GL2-W3.5 and GL2-W3.6; Convex C1 running UNIX; Amhdahl 5840 running UTS; Alliant FX8 running UNIX; Sun 3/160 running UNIX (no native device driver); Stellar GS1000 running Stellex (no native device driver); and an SGI IRIS 4D running IRIX (no native device driver). Currently with version 7.0 of ARCGRAPH, the VDI library supports the following output devices: A VT100 terminal with a RETRO-GRAPHICS board installed, a VT240 using the Tektronix 4010 emulation capability, an SGI IRIS turbo using the native GL2 library, a Tektronix 4010, a Tektronix 4105, and the Tektronix 4014. ARCGRAPH version 7.0 was developed in 1988.
NASA Astrophysics Data System (ADS)
Krauter, Johann; Osten, Wolfgang
2018-03-01
There are a wide range of applications for micro-electro-mechanical systems (MEMS). The automotive and consumer market is the strongest driver for the growing MEMS industry. A 100 % test of MEMS is particularly necessary since these are often used for safety-related purposes such as the ESP (Electronic Stability Program) system. The production of MEMS is a fully automated process that generates 90 % of the costs during the packaging and dicing steps. Nowadays, an electrical test is carried out on each individual MEMS component before these steps. However, after encapsulation, MEMS are opaque to visible light and other defects cannot be detected. Therefore, we apply an infrared low-coherence interferometer for the topography measurement of those hidden structures. A lock-in algorithm-based method is shown to calculate the object height and to reduce ghost steps due to the 2π -unambiguity. Finally, measurements of different MEMS-based sensors are presented.
Flip chip bumping technology—Status and update
NASA Astrophysics Data System (ADS)
Juergen Wolf, M.; Engelmann, Gunter; Dietrich, Lothar; Reichl, Herbert
2006-09-01
Flip chip technology is a key driver for new complex system architectures and high-density packaging, e.g. sensor or pixel devices. Bumped wafers/dice as key elements become very important in terms of general availability at low cost, high yield and quality level. Today, different materials, e.g. Au, Ni, AuSn, SnAg, SnAgCu, SnCu, etc., are used for flip chip interconnects and different bumping approaches are available. Electroplating is the technology of choice for high-yield wafer bumping for small bump sizes and pitches. Lead-free solder bumps require an increase in knowledge in the field of under bump metallization (UBM) and the interaction of bump and substrate metallization, the formation and growth of intermetallic compounds (IMCs) during liquid- and solid-phase reactions. Results of a new bi-layer UBM of Ni-Cu which is especially designed for small-sized lead-free solder bumps will be discussed.
Veltri, Stefania; Bronzetti, Giovanni; Sicoli, Graziella
2011-01-01
This article analyzes the concept of intellectual capital (IC) in the health sector sphere by studying the case of a major nonprofit research organization in this sector, which has for some time been publishing IC reports. In the last few years, health care organizations have been the object of great attention in the implementation and transfer of managerial models and tools; however, there is still a lack of attention paid to the strategic management of IC as a fundamental resource for supporting and enhancing performance improvement dynamics. The main aim of this article is to examine the IC reporting model used by the Center of Molecular Medicine (CMM), a Swedish health organization which is an outstanding benchmark in reporting its IC. We also consider the specifics of IC reporting for health organizations, the lessons learned by analyzing CMM's IC reporting, and future perspectives for research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamlet, Jason; Pierson, Lyndon; Bauer, Todd
Supply chain security to detect, deter, and prevent the counterfeiting of networked and stand-alone integrated circuits (ICs) is critical to cyber security. Sandia National Laboratory researchers have developed IC ID to leverage Physically Unclonable Functions (PUFs) and strong cryptographic authentication to create a unique fingerprint for each integrated circuit. IC ID assures the authenticity of ICs to prevent tampering or malicious substitution.
Integrated circuit authentication using photon-limited x-ray microscopy.
Markman, Adam; Javidi, Bahram
2016-07-15
A counterfeit integrated circuit (IC) may contain subtle changes to its circuit configuration. These changes may be observed when imaged using an x-ray; however, the energy from the x-ray can potentially damage the IC. We have investigated a technique to authenticate ICs under photon-limited x-ray imaging. We modeled an x-ray image with lower energy by generating a photon-limited image from a real x-ray image using a weighted photon-counting method. We performed feature extraction on the image using the speeded-up robust features (SURF) algorithm. We then authenticated the IC by comparing the SURF features to a database of SURF features from authentic and counterfeit ICs. Our experimental results with real and counterfeit ICs using an x-ray microscope demonstrate that we can correctly authenticate an IC image captured using orders of magnitude lower energy x-rays. To the best of our knowledge, this Letter is the first one on using a photon-counting x-ray imaging model and relevant algorithms to authenticate ICs to prevent potential damage.
ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.
Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu
2015-02-01
IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.
Graphene/Si CMOS Hybrid Hall Integrated Circuits
Huang, Le; Xu, Huilong; Zhang, Zhiyong; Chen, Chengying; Jiang, Jianhua; Ma, Xiaomeng; Chen, Bingyan; Li, Zishen; Zhong, Hua; Peng, Lian-Mao
2014-01-01
Graphene/silicon CMOS hybrid integrated circuits (ICs) should provide powerful functions which combines the ultra-high carrier mobility of graphene and the sophisticated functions of silicon CMOS ICs. But it is difficult to integrate these two kinds of heterogeneous devices on a single chip. In this work a low temperature process is developed for integrating graphene devices onto silicon CMOS ICs for the first time, and a high performance graphene/CMOS hybrid Hall IC is demonstrated. Signal amplifying/process ICs are manufactured via commercial 0.18 um silicon CMOS technology, and graphene Hall elements (GHEs) are fabricated on top of the passivation layer of the CMOS chip via a low-temperature micro-fabrication process. The sensitivity of the GHE on CMOS chip is further improved by integrating the GHE with the CMOS amplifier on the Si chip. This work not only paves the way to fabricate graphene/Si CMOS Hall ICs with much higher performance than that of conventional Hall ICs, but also provides a general method for scalable integration of graphene devices with silicon CMOS ICs via a low-temperature process. PMID:24998222
Thermally-induced voltage alteration for integrated circuit analysis
Cole, Jr., Edward I.
2000-01-01
A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.
Graphene/Si CMOS hybrid hall integrated circuits.
Huang, Le; Xu, Huilong; Zhang, Zhiyong; Chen, Chengying; Jiang, Jianhua; Ma, Xiaomeng; Chen, Bingyan; Li, Zishen; Zhong, Hua; Peng, Lian-Mao
2014-07-07
Graphene/silicon CMOS hybrid integrated circuits (ICs) should provide powerful functions which combines the ultra-high carrier mobility of graphene and the sophisticated functions of silicon CMOS ICs. But it is difficult to integrate these two kinds of heterogeneous devices on a single chip. In this work a low temperature process is developed for integrating graphene devices onto silicon CMOS ICs for the first time, and a high performance graphene/CMOS hybrid Hall IC is demonstrated. Signal amplifying/process ICs are manufactured via commercial 0.18 um silicon CMOS technology, and graphene Hall elements (GHEs) are fabricated on top of the passivation layer of the CMOS chip via a low-temperature micro-fabrication process. The sensitivity of the GHE on CMOS chip is further improved by integrating the GHE with the CMOS amplifier on the Si chip. This work not only paves the way to fabricate graphene/Si CMOS Hall ICs with much higher performance than that of conventional Hall ICs, but also provides a general method for scalable integration of graphene devices with silicon CMOS ICs via a low-temperature process.
Rojko, Jennifer L; Evans, Mark G; Price, Shari A; Han, Bora; Waine, Gary; DeWitte, Mark; Haynes, Jill; Freimark, Bruce; Martin, Pauline; Raymond, James T; Evering, Winston; Rebelatto, Marlon C; Schenck, Emanuel; Horvath, Christopher
2014-06-01
Vascular inflammation, infusion reactions, glomerulopathies, and other potentially adverse effects may be observed in laboratory animals, including monkeys, on toxicity studies of therapeutic monoclonal antibodies and recombinant human protein drugs. Histopathologic and immunohistochemical (IHC) evaluation suggests these effects may be mediated by deposition of immune complexes (ICs) containing the drug, endogenous immunoglobulin, and/or complement components in the affected tissues. ICs may be observed in glomerulus, blood vessels, synovium, lung, liver, skin, eye, choroid plexus, or other tissues or bound to neutrophils, monocytes/macrophages, or platelets. IC deposition may activate complement, kinin, and/or coagulation/fibrinolytic pathways and result in a systemic proinflammatory response. IC clearance is biphasic in humans and monkeys (first from plasma to liver and/or spleen, second from liver or spleen). IC deposition/clearance is affected by IC composition, immunomodulation, and/or complement activation. Case studies are presented from toxicity study monkeys or rats and indicate IHC-IC deposition patterns similar to those predicted by experimental studies of IC-mediated reactions to heterologous protein administration to monkeys and other species. The IHC-staining patterns are consistent with findings associated with generalized and localized IC-associated pathology in humans. However, manifestations of immunogenicity in preclinical species are generally not considered predictive to humans. © 2014 by The Author(s).
Alterations of microbiota in urine from women with interstitial cystitis
2012-01-01
Background Interstitial Cystitis (IC) is a chronic inflammatory condition of the bladder with unknown etiology. The aim of this study was to characterize the microbial community present in the urine from IC female patients by 454 high throughput sequencing of the 16S variable regions V1V2 and V6. The taxonomical composition, richness and diversity of the IC microbiota were determined and compared to the microbial profile of asymptomatic healthy female (HF) urine. Results The composition and distribution of bacterial sequences differed between the urine microbiota of IC patients and HFs. Reduced sequence richness and diversity were found in IC patient urine, and a significant difference in the community structure of IC urine in relation to HF urine was observed. More than 90% of the IC sequence reads were identified as belonging to the bacterial genus Lactobacillus, a marked increase compared to 60% in HF urine. Conclusion The 16S rDNA sequence data demonstrates a shift in the composition of the bacterial community in IC urine. The reduced microbial diversity and richness is accompanied by a higher abundance of the bacterial genus Lactobacillus, compared to HF urine. This study demonstrates that high throughput sequencing analysis of urine microbiota in IC patients is a powerful tool towards a better understanding of this enigmatic disease. PMID:22974186
Modularized construction of general integrated circuits on individual carbon nanotubes.
Pei, Tian; Zhang, Panpan; Zhang, Zhiyong; Qiu, Chenguang; Liang, Shibo; Yang, Yingjun; Wang, Sheng; Peng, Lian-Mao
2014-06-11
While constructing general integrated circuits (ICs) with field-effect transistors (FETs) built on individual CNTs is among few viable ways to build ICs with small dimension and high performance that can be compared with that of state-of-the-art Si based ICs, this has not been demonstrated owing to the absence of valid and well-tolerant fabrication method. Here we demonstrate a modularized method for constructing general ICs on individual CNTs with different electric properties. A pass-transistor-logic style 8-transistor (8-T) unit is built, demonstrated as a multifunctional function generator with good tolerance to inhomogeneity in the CNTs used and used as a building block for constructing general ICs. As an example, an 8-bits BUS system that is widely used to transfer data between different systems in a computer is constructed. This is the most complicated IC fabricated on individual CNTs to date, containing 46 FETs built on six individual semiconducting CNTs. The 8-T unit provides a good basis for constructing complex ICs to explore the potential and limits of CNT ICs given the current imperfection in available CNT materials and may also be developed into a universal and efficient way for constructing general ICs on ideal CNT materials in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kisner, R.; Melin, A.; Burress, T.
The objective of this project is to demonstrate improved reliability and increased performance made possible by deeply embedding instrumentation and controls (I&C) in nuclear power plant (NPP) components and systems. The project is employing a highly instrumented canned rotor, magnetic bearing, fluoride salt pump as its I&C technology demonstration platform. I&C is intimately part of the basic millisecond-by-millisecond functioning of the system; treating I&C as an integral part of the system design is innovative and will allow significant improvement in capabilities and performance. As systems become more complex and greater performance is required, traditional I&C design techniques become inadequate andmore » more advanced I&C needs to be applied. New I&C techniques enable optimal and reliable performance and tolerance of noise and uncertainties in the system rather than merely monitoring quasistable performance. Traditionally, I&C has been incorporated in NPP components after the design is nearly complete; adequate performance was obtained through over-design. By incorporating I&C at the beginning of the design phase, the control system can provide superior performance and reliability and enable designs that are otherwise impossible. This report describes the progress and status of the project and provides a conceptual design overview for the platform to demonstrate the performance and reliability improvements enabled by advanced embedded I&C.« less
Engdal, S; Nilsen, O G
2008-06-01
1. The herbal products Natto K2, Agaricus, mistletoe, noni juice, green tea and garlic were investigated for in vitro inhibitory potential on P-glycoprotein (P-gp)-mediated transport of digoxin (30 nM) in differentiated and polarized Caco-2 cells. 2. Satisfactory cell functionality was demonstrated through measurements of assay linearity, transepithelial electric resistance (TEER), cytotoxicity, mannitol permeability, and inclusion of the positive inhibition control verapamil. 3. The most potent inhibitors of the net digoxin flux (IC(50)) were mistletoe > Natto K2 > Agaricus > green tea (0.022, 0.62, 3.81, >4.5 mg ml(-1), respectively). Mistletoe also showed the lowest IC(25) value, close to that obtained by verapamil (1.0 and 0.5 microg ml(-1), respectively). The IC(50)/IC(25) ratio was found to be a good parameter for the determination of inhibition profiles. Garlic and noni juice were classified as non-inhibitors. 4. This study shows that mistletoe, Natto K2, Agaricus and green tea inhibit P-gp in vitro. Special attention should be paid to mistletoe due to very low IC(50) and IC(25) values and to Natto K2 due to a low IC(50) value and a low IC(50)/IC(25) ratio.
Post-Inhaled Corticosteroid Pulmonary Tuberculosis Increases Lung Cancer in Patients with Asthma.
Jian, Zhi-Hong; Huang, Jing-Yang; Lin, Frank Cheau-Feng; Nfor, Oswald Ndi; Jhang, Kai-Ming; Ku, Wen-Yuan; Ho, Chien-Chang; Lung, Chia-Chi; Pan, Hui-Hsien; Wu, Min-Chen; Wu, Ming-Fang; Liaw, Yung-Po
2016-01-01
To evaluate the association between post-inhaled corticosteroid (ICS) pulmonary tuberculosis (TB), pneumonia and lung cancer in patients with asthma. The study samples were collected from the National Health Insurance Database. Asthmatic patients who were first-time users of ICS between 2003 and 2005 were identified as cases. For each case, 4 control individuals were randomly matched for sex, age and date of ICS use. Cases and matched controls were followed up until the end of 2010. Cox proportional hazard regression was used to determine the hazard ratio for pulmonary infections and lung cancer risk in the ICS users and non-users. A total of 10,904 first-time users of ICS were matched with 43,616 controls. The hazard ratios for lung cancer were: 2.52 (95% confidence interval [CI], 1.22-5.22; p = 0.012) for individuals with post-ICS TB, 1.28 (95%CI, 0.73-2.26; p = 0.389) for post-ICS pneumonia, 2.31(95%CI, 0.84-6.38; p = 0.105) for post-ICS pneumonia+TB, 1.08 (95%CI, 0.57-2.03; p = 0.815) for TB, 0.99 (95%CI, 0.63-1.55; p = 0.970) for pneumonia, and 0.32 (95%CI, 0.05-2.32; p = 0.261) for pneumonia+ TB, respectively. Post-ICS TB increased lung cancer risk in patients with asthma. Because of the high mortality associated with lung cancer, screening tests are recommended for patients with post-ICS TB.
Thakur, Anil; Kaur, Kiranpreet; Lamba, Aditya; Taxak, Susheela; Dureja, Jagdish; Singhal, Suresh; Bhardwaj, Mamta
2014-01-01
Background and Aims: Infraclavicular (IC) approach of subclavian vein (SCV) catheterisation is widely used as compared to supraclavicular (SC) approach. The aim of the study was to compare the ease of catheterisation of SCV using SC versus IC approach and also record the incidence of complications related to either approach, if any. Methods: In the study, 60 patients enrolled were randomly divided into two groups of 30 patients each. In Gp. SC right SCV catheterisation was performed using SC approach and in Gp. IC catheterisation was performed using IC approach. Access time, success rate of cannulation, number of attempts to cannulate vein, ease of guidewire and catheter insertion and length of catheter inserted and any associated complications were recorded. Results: The mean access time in group SC for SCV catheterisation was 4.30 ± 1.02 min compared to 6.07 ± 2.14 min in group IC. The overall success rate in catheterisation of the right SCV using SC approach (29 out of 30) was better as compared with group IC (27 out of 30) using IC approach. First attempt success in the SC group was 75.6% as compared with 59.25% in the IC group. All successful subclavian vein catheterisations in SC group and IC group were associated with smooth insertion of guidewire following subclavian venipuncture. Conclusion: The SC approach of SCV catheterisation is comparable to IC approach in terms of landmarks accessibility, success rate and rate of complications. PMID:24963180
Verma, J; Singh, B P; Gangal, S V; Arora, N; Sridhara, S
2000-08-01
Grass pollens are known to induce type I allergic reactions in a large number of genetically predisposed individuals. Earlier studies have recognized Imperata cylindrica (Ic) pollen as an important source of aeroallergen which contained 7 IgE binding proteins in the MW range of 85-16 kD. To isolate, purify and characterize a cross-reactive allergenic protein from Ic pollen extract for diagnosis and therapy of grass pollen allergy. Ic pollen extract was fractionated using DEAE Sephadex A-50, Sephadex G-200 and Mono Q column. Allergenic activity of the fractions was checked by ELISA, skin tests, ELISA inhibition and immunoblot using sera of Ic-sensitive patients. A 67-kD protein was purified to homogeneity from Ic-VIII. The allergenic determinants of this protein were identified by SDS-PAGE and immunoblot after CNBr treatment. Among Ic fractions, Ic-VIII was highly potent by ELISA, skin tests and showed cross-reactivity with 4 other tropical grasses by immunoblot and ELISA inhibition. The subfraction Ic-VIIIe1 of Ic-VIII showed a band at 67 kD on SDS-PAGE. On CNBr treatment, it gave 7 peptides, 3 of which were found to be allergenic. A 67-kD protein (Ic-VIIIe1) was isolated, purified to homogeneity and partially characterized. It showed cross-reactivity with tropical grasses tested and contained at least three allergenic determinants. Copyright 2000 S. Karger AG, Basel.
Organization of infection control in European hospitals.
Hansen, S; Zingg, W; Ahmad, R; Kyratsis, Y; Behnke, M; Schwab, F; Pittet, D; Gastmeier, P
2015-12-01
The Prevention of Hospital Infections by Intervention and Training (PROHIBIT) survey was initiated to investigate the status of healthcare-associated infection (HCAI) prevention across Europe. This paper presents the methodology of the quantitative PROHIBIT survey and outlines the findings on infection control (IC) structure and organization including management's support at the hospital level. Hospitals in 34 countries were invited to participate between September 2011 and March 2012. Respondents included IC personnel and hospital management. Data from 309 hospitals in 24 countries were analysed. Hospitals had a median (interquartile range) of four IC nurses (2-6) and one IC doctor (0-2) per 1000 beds. Almost all hospitals (96%) had defined IC objectives, which mainly addressed hand hygiene (87%), healthcare-associated infection reduction (84%), and antibiotic stewardship (66%). Senior management provided leadership walk rounds in about half of hospitals, most often in Eastern and Northern Europe, 65% and 64%, respectively. In the majority of hospitals (71%), sanctions were not employed for repeated violations of IC practices. Use of sanctions varied significantly by region (P < 0.001), but not by countries' healthcare expenditure. There is great variance in IC staffing and policies across Europe. Some areas of practice, such as hand hygiene, seem to receive considerably more attention than others that are equally important, such as antibiotic stewardship. Programmes in IC suffer from deficiencies in human resources and local policies, ubiquitous factors that negatively impact on IC effectiveness. Strengthening of IC policies in European hospitals should be a public health priority. Copyright © 2015. Published by Elsevier Ltd.
Millar, Anna; Hughes, Carmel; Devlin, Maria; Ryan, Cristín
2016-12-01
Background Despite the importance placed on the concept of the multidisciplinary team in relation to intermediate care (IC), little is known about community pharmacists' (CPs) involvement. Objective To determine CPs' awareness of and involvement with IC services, perceptions of the transfer of patients' medication information between healthcare settings and views of the development of a CP-IC service. Setting Community pharmacies in Northern Ireland. Methods A postal questionnaire, informed by previous qualitative work was developed and piloted. Main outcome measure CPs' awareness of and involvement with IC. Results The response rate was 35.3 % (190/539). Under half (47.4 %) of CPs 'agreed/strongly agreed' that they understood the term 'intermediate care'. Three quarters of respondents were either not involved or unsure if they were involved with providing services to IC. A small minority (1.2 %) of CPs reported that they received communication regarding medication changes made in hospital or IC settings 'all of the time'. Only 9.5 and 0.5 % of respondents 'strongly agreed' that communication from hospital and IC, respectively, was sufficiently detailed. In total, 155 (81.6 %) CPs indicated that they would like to have greater involvement with IC services. 'Current workload' was ranked as the most important barrier to service development. Conclusion It was revealed that CPs had little awareness of, or involvement with, IC. Communication of information relating to patients' medicines between settings was perceived as insufficient, especially between IC and community pharmacy settings. CPs demonstrated willingness to be involved with IC and services aimed at bridging the communication gap between healthcare settings.
Giri, S. N.; Hyde, D. M.
1988-01-01
The effects of polyinosinic-polycytidylic acid (Poly I:C), an inducer of interferons, on bleomycin (Bleo)-induced lung fibrosis was studied in hamsters. Poly I:C (10 mg/kg intraperitoneally) was administered for two days and immediately before intratracheal instillation of bleomycin (7.5 U/kg) or an equivalent volume of saline and thereafter daily for 13 days. The lung hydroxyproline in control, Poly I:C, Bleo, and Bleo + Poly I:C groups averaged 791, 752, 1177, and 766 micrograms/lung. As compared to control, the prolyl hydroxylase activity in the Bleo group was increased by 83% whereas in Bleo + Poly I:C group, the activity was increased by 42%. Protein in the bronchoalveolar lavage supernatant in Poly I:C, Bleo and Bleo + Poly I:C groups were 72, 286, and 206% of the control, respectively. There was no difference in total leukocyte counts between Bleo + Poly I:C and Bleo groups, but the differential cell counts were changed. The numbers of neutrophils, monocytes, lymphocytes, and eosinophils were 50, 84, 91, and 10% of Bleo group, respectively. Morphometric estimates of the volume of parenchymal lesion within the lung showed that hamsters in Bleo + Poly I:C group had significantly less volume of lesion (1.0 cucm) than the Bleo group (1.6 cucm). In addition, the fibrotic lesions in Bleo + Poly I:C group were multifocal and primarily proximal acinar in location, had fewer extracellular fibers, neutrophils and monocytes. Poly I:C treatment ameliorated bleomycin-induced lung collagen accumulation. Images Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 PMID:2462354
Interpersonal Callousness and Co-Occurring Anxiety: Developmental Validity of an Adolescent Taxonomy
2016-01-01
Growing evidence suggests heterogeneity within interpersonal-callous (IC) youth based on co-occurring anxiety. The developmental validity of this proposed taxonomy remains unclear however, as most previous research is cross-sectional and/or limited to adolescence. We aimed to identify low-anxiety (IC/ANX−) and high-anxiety (IC/ANX+) IC variants, and compare these groups on (a) early risk exposures, (b) psychiatric symptoms from midchildhood to early adolescence, and (c) school-based functioning. Using the Avon Longitudinal Study of Parents and Children (ALSPAC), a prospective epidemiological birth cohort, model-based cluster analysis was performed on children with complete age-13 IC and anxiety scores (n = 6,791). Analysis of variance was used to compare resulting clusters on (a) prenatal and postnatal family adversity and maternal psychopathology, and harsh parenting; (b) developmental differences in attention-deficit/hyperactivity disorder (ADHD), conduct disorder (CD), oppositional defiant disorder (ODD), emotional difficulties, and low pro-social behavior at 7, 10, and 13 years; and (c) teacher-reported discipline problems, along with standardized test performance. We identified a 4-cluster solution: “typical,” “low,” “IC/ANX−”, and “IC/ANX+.” IC/ANX+ youth showed the highest prenatal and postnatal levels of family adversity and maternal psychopathology, highest levels of ADHD, CD, ODD, and emotional difficulties, greatest discipline problems, and lowest national test scores (all p < .001). IC/ANX+ also showed a distinct pattern of increasing psychopathology from age 7 to 13 years. Adolescent IC subtypes were successfully validated in ALSPAC across multiple raters using prenatal and early postnatal risk, repeated measures of psychopathology, and school-based outcomes. Greater prenatal environmental risk among IC/ANX+ youth suggests an important target for early intervention. PMID:27977232
Mo, Xiao-Dong; Zhang, Xiao-Hui; Xu, Lan-Ping; Wang, Yu; Yan, Chen-Hua; Chen, Huan; Chen, Yu-Hong; Han, Wei; Wang, Feng-Rong; Wang, Jing-Zhi; Liu, Kai-Yan; Huang, Xiao-Jun
2016-12-01
Allogeneic hematopoietic stem cell transplantation (HSCT) is an important therapy option for children with acute myeloid leukemia (AML) resistant to the first course of induction chemotherapy (IC 1st ). We aimed to identify the efficacy of unmanipulated haploidentical HSCT (haplo-HSCT) in children with AML in the first complete remission and whether children resistant (IC 1st -resistant; n = 38) or sensitive (IC 1st -sensitive; n = 59) to the IC 1st can achieve comparable outcomes. The cumulative incidence of grades III to IV acute graft-versus-host disease (GVHD) and severe chronic GVHD was .0% versus 20.1% (P = .038) and 21.7% versus 13.2% (P = .238), respectively, for the IC 1st -resistant and IC 1st -sensitive groups. The 3-year cumulative incidence of relapse and nonrelapse mortality was 22.2% versus 7.6% (P = .061) and 5.3% versus 10.8% (P = .364), respectively, for the IC 1st -resistant and IC 1st -sensitive groups. The 3-year probability of overall survival and disease-free survival was 76.3% versus 83.0% (P = .657) and 72.5% versus 81.6% (P = .396), respectively, for the IC 1st -resistant and IC 1st -sensitive groups. Multivariate analysis failed to show significant differences in survival rates between the groups. Thus, our results show that unmanipulated haplo-HSCT may overcome the poor prognostic significance of IC 1st -resistance in children with AML, and it is valid as a postremission treatment for children with IC 1st -resistant AML lacking an HLA-matched donor. Copyright © 2016 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Rashid, Khwaja Aftab; Foster, C Stephen; Ahmed, A Razzaque
2013-11-19
To identify the epitopes on human β4 integrin to which the sera of patients with ocular cicatricial pemphigoid (OCP) and mucous membrane pemphigoid (MMP) without ocular involvement bind. Fragments of the intracellular domain of the β4 molecule were cloned, expressed, purified and peptides were synthesized. Antibodies to various fragments and peptides were produced in rabbits. Binding specificity was determined via Western blot and blocking experiments. Test sera and controls were injected into neonatal BALB/c mice for in vivo passive transfer. Sera from patients with OCP, MMP, and both OCP and MMP were bound to cloned fragments of IC3.0. Its subcloned fragments IC3.4 (1489 aa-1572 aa) and IC3.4.1 (1489 aa-1510 aa) were bound with the sera from patients with OCP only. Subcloned fragments IC3.6 (1573 aa-1822 aa) and IC3.6.1 (1689 aa-1702 aa) were bound with MMP sera only. No cross-reactivity in binding was observed. Immuno-affinity-purified sera from patients with OCP, MMP, and rabbit antibodies to IC3.0, IC3.4, IC3.4.1, IC3.6, and IC3.6.1, when injected in neonatal BALB/c mice, produced subepidermal blisters in their skin. These preliminary observations identified IC3.4.1 as the possible epitope for the binding of OCP auto-antibody and IC3.6.1 as the possible epitope for the binding of MMP auto-antibody without ocular disease. Antibodies specific to these peptides produced blisters when injected in mice. Still-unidentified epitopes may exist. These observations may enhance our understanding of the role of β4 integrin in the pathobiology of OCP and MMP. Early diagnosis may be possible if serologic tests with specificity and sensitivity can be developed.
Ni, Songshi; Fu, Zhenxue; Zhao, Jing; Liu, Hua
2014-07-01
Studies have indicated that therapy with inhaled corticosteroids (ICS) can be associated with a higher risk of pneumonia. However, it is not known whether ICS increases the risk of mycobacterium. Most of these published studies were small, and the conclusions were inconsistent. A meta-analysis was conducted into whether ICS increases the risk of mycobacterium in patients with chronic respiratory diseases. PubMed, OVID, EMBASE and Cochrane Library databases were searched. Five studies involving 4,851 cases and 28,477 controls were considered in the meta-analysis. From the pooled analyses, there was significant association between ICS and risk of mycobacterium in all patients with chronic respiratory diseases [risk ratio (RR) =1.81; 95% confidence interval (CI), 1.23-2.68; P=0.003]. Among patients with chronic respiratory diseases, the relationship between ICS and risk of tuberculosis (TB) was also significant (RR =1.34; 95% CI, 1.15-1.55; P=0.0001). And meta-analysis of four studies in patients with chronic obstructive pulmonary disease (COPD) (RR =1.42; 95% CI, 1.18-1.72; P=0.0003) or two studies in patients who have prior pulmonary TB (RR =1.61; 95% CI, 1.35-1.92; P<0.00001) or three studies in patients with high-dose ICS (RR =1.60; 95% CI, 1.28-1.99; P<0.0001) showed a relationship between ICS and risk of mycobacterium. Significant relationship has been shown between ICS use and risk of mycobacterium in all patients with chronic respiratory diseases. ICS use also increases the risk of TB among the patients with chronic respiratory diseases. Use of ICS increases the risk of mycobacterium in patients with COPD or patients with prior pulmonary TB or patients inhaling high-dose corticosteroids. Further research is required to establish the potential adverse effect of ICS as a therapy for chronic respiratory diseases.
PROGRESS IN DESIGN OF THE INSTRUMENTATION AND CONTROL OF THE TOKAMAK COOLING WATER SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korsah, Kofi; DeVan, Bill; Ashburn, David
This paper discusses progress in the design of the control, interlock and safety systems of the Tokamak Cooling Water System (TCWS) for the ITER fusion reactor. The TCWS instrumentation and control (I&C) is one of approximately 200 separate plant I&C systems (e.g., vacuum system I&C, magnets system I&C) that interface to a common central I&C system through standardized networks. Several aspects of the I&C are similar to the I&C of fission-based power plants. However, some of the unique features of the ITER fusion reactor and the TCWS (e.g., high quasi-static magnetic field, need for baking and drying as well asmore » cooling operations), also demand some unique safety and qualification considerations. The paper compares the design strategy/guidelines of the TCWS I&C and the I&C of conventional nuclear power plants. Issues such as safety classifications, independence between control and safety systems, sensor sharing, redundancy, voting schemes, and qualification methodologies are discussed. It is concluded that independence and separation requirements are similar in both designs. However, the voting schemes for safety systems in nuclear power plants typically use 2oo4 (i.e., 4 divisions of safety I&C, any 2 of which is sufficient to trigger a safety action), while 2oo3 voting logic - within each of 2 independent trains - is used in the TCWS I&C. It is also noted that 2oo3 voting is also acceptable in nuclear power plants if adequate risk assessment and reliability is demonstrated. Finally, while qualification requirements provide similar guidance [e.g., both IEC 60780 (invoked in ITER-space), and IEEE 323 (invoked in fission power plant space) provide similar guidance], an important qualification consideration is the susceptibility of I&C to the magnetic fields of ITER. Also, the radiation environments are different. In the case of magnetic fields the paper discusses some options that are being considered.« less
Banerjee, A; Emanuel, K; Parafina, J; Bagchi, M
1992-10-01
A water soluble growth inhibitor was isolated from the mammalian ocular iris-ciliary complex. The molecular weight of this protein is 10 kD or lower as determined by ultrafiltration fractionation. The iris-ciliary (IC) complex water soluble protein(s) significantly inhibits synthesis of lower molecular weight proteins of the epithelial cells of the organ cultured mammalian ocular lens. It was also found that this inhibitory effect of IC is mediated via the structural organization of the lens. Monolayer cultures of the lens epithelial cells exposed to IC did not manifest any inhibition of their protein synthesis. Moreover, these tissue cultured lens epithelial (TCLE) cells showed a significant increase in their protein synthetic activities in response to the presence of IC factors in the culture medium. It is postulated that the IC activity is modulated via either the lens capsule, an extracellular matrix, or due to the specific organization of the intact lens. The specific effects of IC on the cytoskeletal organization and synthesis in the organ cultured lens epithelial (OCLE) and TCLE cells were also examined. Both groups, treated with IC factors, manifested significant alterations in their protein synthetic activities and cytoskeletal architecture. The 3H-leucine incorporation experiments showed that alpha-actin and alpha-tubulin synthesis is partially inhibited by IC factors in OCLE cells but vimentin synthesis is not, whereas in TCLE cells all of them showed increased synthesis in response to IC factors. Turnover rates of these proteins in both OCLE and TCLE cells were also computed. The immunofluorescence and microscopic evaluation of OCLE and TCLE cells exposed to IC factors illustrated significant alteration in the cytoarchitecture of the filaments. We demonstrate that an inhibitor(s) molecule of 10 kD or lower size isolated from IC inhibited protein synthesis of OCLE cells and stimulated protein synthesis in TCLE cells. The IC factor also affects the synthesis and organization of cytoskeletal filaments of both the OCLE and TCLE cells.
Wang, Guoqing; Hou, Zhenyu; Peng, Yang; Wang, Yanjun; Sun, Xiaoli; Sun, Yu-an
2011-11-07
By determination of the number of absorptive chemical components (ACCs) in mixtures using median absolute deviation (MAD) analysis and extraction of spectral profiles of ACCs using kernel independent component analysis (KICA), an adaptive KICA (AKICA) algorithm was proposed. The proposed AKICA algorithm was used to characterize the procedure for processing prepared rhubarb roots by resolution of the measured mixed raw UV spectra of the rhubarb samples that were collected at different steaming intervals. The results show that the spectral features of ACCs in the mixtures can be directly estimated without chemical and physical pre-separation and other prior information. The estimated three independent components (ICs) represent different chemical components in the mixtures, which are mainly polysaccharides (IC1), tannin (IC2), and anthraquinone glycosides (IC3). The variations of the relative concentrations of the ICs can account for the chemical and physical changes during the processing procedure: IC1 increases significantly before the first 5 h, and is nearly invariant after 6 h; IC2 has no significant changes or is slightly decreased during the processing procedure; IC3 decreases significantly before the first 5 h and decreases slightly after 6 h. The changes of IC1 can explain why the colour became black and darkened during the processing procedure, and the changes of IC3 can explain why the processing procedure can reduce the bitter and dry taste of the rhubarb roots. The endpoint of the processing procedure can be determined as 5-6 h, when the increasing or decreasing trends of the estimated ICs are insignificant. The AKICA-UV method provides an alternative approach for the characterization of the processing procedure of rhubarb roots preparation, and provides a novel way for determination of the endpoint of the traditional Chinese medicine (TCM) processing procedure by inspection of the change trends of the ICs.
Brant, Jason O; Riva, Alberto; Resnick, James L; Yang, Thomas P
2014-01-01
Reduced representation bisulfite sequencing (RRBS) was used to analyze DNA methylation patterns across the mouse brain genome in mice carrying a deletion of the Prader-Willi syndrome imprinting center (PWS-IC) on either the maternally- or paternally-inherited chromosome. Within the ∼3.7 Mb imprinted Angelman/Prader-Willi syndrome (AS/PWS) domain, 254 CpG sites were interrogated for changes in methylation due to PWS-IC deletion. Paternally-inherited deletion of the PWS-IC increased methylation levels ∼2-fold at each CpG site (compared to wild-type controls) at differentially methylated regions (DMRs) associated with 5′ CpG island promoters of paternally-expressed genes; these methylation changes extended, to a variable degree, into the adjacent CpG island shores. Maternal PWS-IC deletion yielded little or no changes in methylation at these DMRs, and methylation of CpG sites outside of promoter DMRs also was unchanged upon maternal or paternal PWS-IC deletion. Using stringent ascertainment criteria, ∼750,000 additional CpG sites were also interrogated across the entire mouse genome. This analysis identified 26 loci outside of the imprinted AS/PWS domain showing altered DNA methylation levels of ≥25% upon PWS-IC deletion. Curiously, altered methylation at 9 of these loci was a consequence of maternal PWS-IC deletion (maternal PWS-IC deletion by itself is not known to be associated with a phenotype in either humans or mice), and 10 of these loci exhibited the same changes in methylation irrespective of the parental origin of the PWS-IC deletion. These results suggest that the PWS-IC may affect DNA methylation at these loci by directly interacting with them, or may affect methylation at these loci through indirect downstream effects due to PWS-IC deletion. They further suggest the PWS-IC may have a previously uncharacterized function outside of the imprinted AS/PWS domain. PMID:25482058
Brant, Jason O; Riva, Alberto; Resnick, James L; Yang, Thomas P
2014-11-01
Reduced representation bisulfite sequencing (RRBS) was used to analyze DNA methylation patterns across the mouse brain genome in mice carrying a deletion of the Prader-Willi syndrome imprinting center (PWS-IC) on either the maternally- or paternally-inherited chromosome. Within the ~3.7 Mb imprinted Angelman/Prader-Willi syndrome (AS/PWS) domain, 254 CpG sites were interrogated for changes in methylation due to PWS-IC deletion. Paternally-inherited deletion of the PWS-IC increased methylation levels ~2-fold at each CpG site (compared to wild-type controls) at differentially methylated regions (DMRs) associated with 5' CpG island promoters of paternally-expressed genes; these methylation changes extended, to a variable degree, into the adjacent CpG island shores. Maternal PWS-IC deletion yielded little or no changes in methylation at these DMRs, and methylation of CpG sites outside of promoter DMRs also was unchanged upon maternal or paternal PWS-IC deletion. Using stringent ascertainment criteria, ~750,000 additional CpG sites were also interrogated across the entire mouse genome. This analysis identified 26 loci outside of the imprinted AS/PWS domain showing altered DNA methylation levels of ≥25% upon PWS-IC deletion. Curiously, altered methylation at 9 of these loci was a consequence of maternal PWS-IC deletion (maternal PWS-IC deletion by itself is not known to be associated with a phenotype in either humans or mice), and 10 of these loci exhibited the same changes in methylation irrespective of the parental origin of the PWS-IC deletion. These results suggest that the PWS-IC may affect DNA methylation at these loci by directly interacting with them, or may affect methylation at these loci through indirect downstream effects due to PWS-IC deletion. They further suggest the PWS-IC may have a previously uncharacterized function outside of the imprinted AS/PWS domain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yanfeng; Gao, Xiaoli; Michael Garavito, R., E-mail: garavito@msu.edu
2011-04-22
Highlights: {yields} Crystal structure of the intracellular domain of (pro)renin receptor (PRR-IC) as MBP fusion protein at 2.0 A (maltose-free) and 2.15 A (maltose-bound). {yields} MBP fusion protein is a dimer in crystals in the presence and absence of maltose. {yields} PRR-IC domain is responsible for the dimerization of the fusion protein. {yields} Residues in the PRR-IC domain, particularly two tyrosines, dominate the intermolecular interactions, suggesting a role for the PRR-IC domain in PRR dimerization. -- Abstract: The (pro)renin receptor (PRR) is an important component of the renin-angiotensin system (RAS), which regulates blood pressure and cardiovascular function. The integral membranemore » protein PRR contains a large extracellular domain ({approx}310 amino acids), a single transmembrane domain ({approx}20 amino acids) and an intracellular domain ({approx}19 amino acids). Although short, the intracellular (IC) domain of the PRR has functionally important roles in a number of signal transduction pathways activated by (pro)renin binding. Meanwhile, together with the transmembrane domain and a small portion of the extracellular domain ({approx}30 amino acids), the IC domain is also involved in assembly of V{sub 0} portion of the vacuolar proton-translocating ATPase (V-ATPase). To better understand structural and multifunctional roles of the PRR-IC, we report the crystal structure of the PRR-IC domain as maltose-binding protein (MBP) fusion proteins at 2.0 A (maltose-free) and 2.15 A (maltose-bound). In the two separate crystal forms having significantly different unit-cell dimensions and molecular packing, MBP-PRR-IC fusion protein was found to be a dimer, which is different with the natural monomer of native MBP. The PRR-IC domain appears as a relatively flexible loop and is responsible for the dimerization of MBP fusion protein. Residues in the PRR-IC domain, particularly two tyrosines, dominate the intermonomer interactions, suggesting a role for the PRR-IC domain in protein oligomerization.« less
Freesmeyer, Martin; Kühnel, Christian; Westphal, Julian G
2015-01-01
Benign thyroid diseases are widely common in western societies. However, the volumetry of the thyroid gland, especially when enlarged or abnormally formed, proves to be a challenge in clinical routine. The aim of this study was to develop a simple and rapid threshold-based isocontour extraction method for thyroid volumetry from (124)I-PET/CT data in patients scheduled for radioactive iodine therapy. PET/CT data from 45 patients were analysed 30 h after 1 MBq (124)I administration. Anatomical reference volume was calculated using manually contoured data from low-dose CT images of the neck (MC). In addition, we applied an automatic isocontour extraction method (IC0.2/1.0), with two different threshold values (0.2 and 1.0 kBq/ml), for volumetry of the PET data-set. IC0.2/1.0 shape data that showed significant variation from MC data were excluded. Subsequently, a mathematical correlation using a model of linear regression with multiple variables and step-wise elimination (mIC0.2/1.0), between IC0.2/1.0 and MC, was established. Data from 41 patients (IC0.2), and 32 patients (IC1.0) were analysed. The mathematically calculated volume, mIC, showed a median deviation from the reference (MC), of ±9 % (1-54 %) for mIC0.2 and of ±8.2 % (1-50 %) for mIC1.0 CONCLUSION: Contour extraction with both, mIC1.0 and mIC0.2 gave rapid and reliable results. However, mIC0.2 can be applied to significantly more patients (>90 %) and is, therefore, deemed to be more suitable for clinical routine, keeping in mind the potential advantages of using (124)I-PET/CT for the preparation of patients scheduled for radioactive iodine therapy.
DiSantostefano, Rachael L.; Sampson, Tim; Le, Hoa Van; Hinds, David; Davis, Kourtney J.; Bakerly, Nawar Diar
2014-01-01
Introduction Observational studies using case-control designs have showed an increased risk of pneumonia associated with inhaled corticosteroid (ICS)-containing medications in patients with chronic obstructive pulmonary disease (COPD). New-user observational cohort designs may minimize biases associated with previous case-control designs. Objective To estimate the association between ICS and pneumonia among new users of ICS relative to inhaled long-acting bronchodilator (LABD) monotherapy. Methods Pneumonia events in COPD patients ≥45 years old were compared among new users of ICS medications (n = 11,555; ICS, ICS/long-acting β2-agonist [LABA] combination) and inhaled LABD monotherapies (n = 6,492; LABA, long-acting muscarinic antagonists) using Cox proportional hazards models, with propensity scores to adjust for confounding. Setting: United Kingdom electronic medical records with linked hospitalization and mortality data (2002–2010). New users were censored at earliest of: pneumonia event, death, changing/discontinuing treatment, or end of follow-up. Outcomes: severe pneumonia (primary) and any pneumonia (secondary). Results Following adjustment, new use of ICS-containing medications was associated with an increased risk of pneumonia hospitalization (n = 322 events; HR = 1.55, 95% CI: 1.14, 2.10) and any pneumonia (n = 702 events; HR = 1.49, 95% CI: 1.22, 1.83). Crude incidence rates of any pneumonia were 48.7 and 30.9 per 1000 person years among the ICS-containing and LABD cohorts, respectively. Excess risk of pneumonia with ICS was reduced when requiring ≥1 month or ≥ 6 months of new use. There was an apparent dose-related effect, with greater risk at higher daily doses of ICS. There was evidence of channeling bias, with more severe patients prescribed ICS, for which the analysis may not have completely adjusted. Conclusions The results of this new-user cohort study are consistent with published findings; ICS were associated with a 20–50% increased risk of pneumonia in COPD, which reduced with exposure time. This risk must be weighed against the benefits when prescribing ICS to patients with COPD. PMID:24878543
Jiménez-Alejo, Abel; Morales-Pérez, Arcadio; Nava-Aguilera, Elizabeth; Flores-Moreno, Miguel; Apreza-Aguilar, Sinahí; Carranza-Alcaraz, Wilhelm; Cortés-Guzmán, Antonio Juan; Fernández-Salas, Ildefonso; Ledogar, Robert J; Cockcroft, Anne; Andersson, Neil
2017-05-30
The follow-up survey of a cluster-randomised controlled trial of evidence-based community mobilisation for dengue control in Nicaragua and Mexico included entomological information from the 2012 rainy and dry seasons. We used data from the Mexican arm of the trial to assess the impact of the community action on pupal production of the dengue vector Aedes aegypti in both rainy and dry seasons. Trained field workers inspected household water containers in 90 clusters and collected any pupae or larvae present for entomological examination. We calculated indices of pupae per person and pupae per household, and traditional entomological indices of container index, household index and Breteau index, and compared these between rainy and dry seasons and between intervention and control clusters, using a cluster t-test to test significance of differences. In 11,933 houses in the rainy season, we inspected 40,323 containers and found 7070 Aedes aegypti pupae. In the dry season, we inspected 43,461 containers and counted 6552 pupae. All pupae and entomological indices were lower in the intervention clusters (IC) than in control clusters (CC) in both the rainy season (RS) and the dry season (DS): pupae per container 0.12 IC and 0.24 CC in RS, and 0.10 IC and 0.20 CC in DS; pupae per household 0.46 IC and 0.82 CC in RS, and 0.41 IC and 0.83 CC in DS; pupae per person 0.11 IC and 0.19 CC in RS, and 0.10 IC and 0.20 CC in DS; household index 16% IC and 21% CC in RS, and 12.1% IC and 17.9% CC in DS; container index 7.5% IC and 11.5% CC in RS, and 4.6% IC and 7.1% CC in DS; Breteau index 27% IC and 36% CC in RS, and 19% IC and 29% CC in DS. All differences between the intervention and control clusters were statistically significant, taking into account clustering. The trial intervention led to significant decreases in pupal and conventional entomological indices in both rainy and dry seasons. ISRCTN27581154 .
Intelligibility in Context Scale: Normative and Validation Data for English-Speaking Preschoolers.
McLeod, Sharynne; Crowe, Kathryn; Shahaeian, Ameneh
2015-07-01
The purpose of this study was to describe normative and validation data on the Intelligibility in Context Scale (ICS; McLeod, Harrison, & McCormack, 2012c) for English-speaking children. The ICS is a 7-item, parent-report measure of children's speech intelligibility with a range of communicative partners. Data were collected from the parents of 803 Australian English-speaking children ranging in age from 4;0 (years;months) to 5;5 (37.0% were multilingual). The mean ICS score was 4.4 (SD = 0.7) out of a possible total score of 5. Children's speech was reported to be most intelligible to their parents, followed by their immediate family, friends, and teachers; children's speech was least intelligible to strangers. The ICS had high internal consistency (α = .94). Significant differences in scores were identified on the basis of sex and age but not on the basis of socioeconomic status or the number of languages spoken. There were significant differences in scores between children whose parents had concerns about their child's speech (M = 3.9) and those who did not (M = 4.6). A sensitivity of .82 and a specificity of .58 were established as the optimal cutoff. Test-retest reliability and criterion validity were established for 184 children with a speech sound disorder. There was a significant low correlation between the ICS mean score and percentage of phonemes correct (r = .30), percentage of consonants correct (r = .24), and percentage of vowels correct (r = .30) on the Diagnostic Evaluation of Articulation and Phonology (Dodd, Hua, Crosbie, Holm, & Ozanne, 2002). Thirty-one parents completed the ICS related to English and another language spoken by their child with a speech sound disorder. The significant correlations between the scores suggest that the ICS may be robust between languages. This article provides normative ICS data for English-speaking children and additional validation of the psychometric properties of the ICS. The robustness of the ICS was suggested because mean ICS scores were not affected by socioeconomic status, number of languages spoken, or whether the ICS was completed in relation to English or another language. The ICS is recommended as a screening measure of children's speech intelligibility.
Khadake, Jyoti; Heggestad, Arnold D.; Ma, Xiaojie; Johnstone, Karen A.; Resnick, James L.; Yang, Thomas P.
2013-01-01
The Angelman/Prader-Willi syndrome (AS/PWS) domain contains at least 8 imprinted genes regulated by a bipartite imprinting center (IC) associated with the SNRPN gene. One component of the IC, the PWS-IC, governs the paternal epigenotype and expression of paternal genes. The mechanisms by which imprinting and expression of paternal genes within the AS/PWS domain – such as MKRN3 and NDN – are regulated by the PWS-IC are unclear. The syntenic region in the mouse is organized and imprinted similarly to the human domain with the murine PWS-IC defined by a 6 kb interval within the Snrpn locus that includes the promoter. To identify regulatory elements that may mediate PWS-IC function, we mapped the location and allele-specificity of DNase I hypersensitive (DH) sites within the PWS-IC in brain cells, then identified transcription factor binding sites within a subset of these DH sites. Six major paternal-specific DH sites were detected in the Snrpn gene, five of which map within the 6 kb PWS-IC. We postulate these five DH sites represent functional components of the murine PWS-IC. Analysis of transcription factor binding within multiple DH sites detected nuclear respiratory factors (NRF's) and YY1 specifically on the paternal allele. NRF's and YY1 were also detected in the paternal promoter region of the murine Mrkn3 and Ndn genes. These results suggest that NRF's and YY1 may facilitate PWS-IC function and coordinately regulate expression of paternal genes. The presence of NRF's also suggests a link between transcriptional regulation within the AS/PWS domain and regulation of respiration. 3C analyses indicated Mkrn3 lies in close proximity to the PWS-IC on the paternal chromosome, evidence that the PWS-IC functions by allele-specific interaction with its distal target genes. This could occur by allele-specific co-localization of the PWS-IC and its target genes to transcription factories containing NRF's and YY1. PMID:23390487
NASA Team 2 Sea Ice Concentration Algorithm Retrieval Uncertainty
NASA Technical Reports Server (NTRS)
Brucker, Ludovic; Cavalieri, Donald J.; Markus, Thorsten; Ivanoff, Alvaro
2014-01-01
Satellite microwave radiometers are widely used to estimate sea ice cover properties (concentration, extent, and area) through the use of sea ice concentration (IC) algorithms. Rare are the algorithms providing associated IC uncertainty estimates. Algorithm uncertainty estimates are needed to assess accurately global and regional trends in IC (and thus extent and area), and to improve sea ice predictions on seasonal to interannual timescales using data assimilation approaches. This paper presents a method to provide relative IC uncertainty estimates using the enhanced NASA Team (NT2) IC algorithm. The proposed approach takes advantage of the NT2 calculations and solely relies on the brightness temperatures (TBs) used as input. NT2 IC and its associated relative uncertainty are obtained for both the Northern and Southern Hemispheres using the Advanced Microwave Scanning Radiometer for the Earth Observing System (AMSR-E) TB. NT2 IC relative uncertainties estimated on a footprint-by-footprint swath-by-swath basis were averaged daily over each 12.5-km grid cell of the polar stereographic grid. For both hemispheres and throughout the year, the NT2 relative uncertainty is less than 5%. In the Southern Hemisphere, it is low in the interior ice pack, and it increases in the marginal ice zone up to 5%. In the Northern Hemisphere, areas with high uncertainties are also found in the high IC area of the Central Arctic. Retrieval uncertainties are greater in areas corresponding to NT2 ice types associated with deep snow and new ice. Seasonal variations in uncertainty show larger values in summer as a result of melt conditions and greater atmospheric contributions. Our analysis also includes an evaluation of the NT2 algorithm sensitivity to AMSR-E sensor noise. There is a 60% probability that the IC does not change (to within the computed retrieval precision of 1%) due to sensor noise, and the cumulated probability shows that there is a 90% chance that the IC varies by less than +/-3%. We also examined the daily IC variability, which is dominated by sea ice drift and ice formation/melt. Daily IC variability is the highest, year round, in the MIZ (often up to 20%, locally 30%). The temporal and spatial distributions of the retrieval uncertainties and the daily IC variability is expected to be useful for algorithm intercomparisons, climate trend assessments, and possibly IC assimilation in models.
[Clinical efficacy of alternating chemo-radiotherapy for locally advanced nasopharyngeal carcinoma].
You, Xi; Yang, Yucheng
2014-03-01
The purpose of this study is to investigate the effective of alternating Chemo-radiotherapy for locally Advanced Nasopharyngeal Carcinoma. Retrospective analysis 106 cases of patients with locally advanced nasopharyngeal carcinoma between November 2005 and March 2007. All patients received cisplatin-based chemotherapy but 15 patients received radiotherapy(RT) alone. Inducing chemotherapy (IC) + RT + adju-vant chemotherapy (AC) regimen in 36 patients, IC+RT regimen was delivered in 25 patients and AC + RT regimen in 30 patients. 61 patients received 1 to 2 cycles of inducing chemotherapy and 66 patients received 3 to 6 cycles of adjuvant chemotherapy after radiotherapy. Chemotherapy started on the first day after the end of the induction chemotherapy, adjuvant chemotherapy begun after radiotherapy for a week. All patients were treated by radiotherapy using 60 Co r-ray, the nasophyarynx primary site was given a total does of 68 -74 Gy. The lymph nodes of the neck was given 60 to 70 Gy. The prophylactic irradiation does of the neck was 48-50 Gy. RESCULT: The median follow up time was 51 months. A total of 58 patients died, the overall survival rate was 45% in whole groups. The 5-year overall survival rates were 33%, 63%, 60% and 50% in RT, IC + RT + AC, IC + RT and RT+AC group, respectively. The 5-year disease-free survival rates were 13%, 56%, 48% and 40% in RT, IC + RT + AC, IC + RT and RT + AC group, respectively. The 5-year relapse-free survival rates were 13%, 53%, 48% and 50% in RT, IC + RT + AC, IC + RT and RT + AC group, respectively. The 5-year metastasis-free survival rates were 6%, 50%, 44% and 47% in RT, IC + RT + AC, IC+ RT and RT + AC group, respectively. There was significant difference in all groups (P < 0.05). The median time to relapses were 22 months, 29 months, 28 months and 25 months in RT, IC + RT + AC, IC + RT and RT + AC group, respectively. The median time to first distant metastasis were 10 months, 19 months, 15 months and 12 months in RT, IC + RT + AC, IC + RT and RT + AC group, respectively. There was no significant difference in all groups (P > 0.05). IC + RT + AC group had heavier acute toxicity effects than other groups, but it did not affect the treatment process, all patients could be tolerated. This retrospective study has demonstrated that alternating Chemo-radiotherapy and early radiotherapy not only can improve the survival rate for locally Advanced Nasopharyngeal Carcinoma, but also have slight toxicities and side reaction, all patients may tolerated.
Allen-Ramey, Felicia C; Bukstein, Don; Luskin, Allan; Sajjan, Shiva G; Markson, Leona E
2006-05-01
To compare asthma-related health care resource utilization among a matched cohort of asthma patients using inhaled corticosteroids (ICSs) plus either montelukast (MON) or salmeterol (SAL) as combination therapy for asthma, during a time prior to the availability of fixed-dose combinations of ICS/SAL. A retrospective analysis using the PHARMetrics patient-centric claims database was conducted for the period preceding the market introduction of combination fluticasone-SAL in September 2000. Patients had to meet the following criteria for inclusion in the study: they had to be between the ages of 4 and 55 years; they had to have been continuously enrolled for 2 years; they had to have initiated ICS/MON or ICS/SAL therapy between July 1, 1998, and June 30, 1999; and they had to have had either (a) a diagnosis of asthma (based on International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes of 493.xx) for 2 outpatient visits, 1 or more emergency department (ED) visits, or 1 or more hospitalizations within 1 year or (b) pharmacy claim records that contained a National Drug Code for an antiasthma medication (betaagonist, theophylline, ICS, cromolyn, or leukotriene) 2 or more times within 1 year. ICS/MON and ICS/SAL patients were matched 1 to 1 on age and propensity score. Outcomes included asthma-related hopitalizations and ED visits with ICD-9-CM codes of 493.xx, and oral corticosteroid (OCS) fills and short-acting beta-agonist (SABA) fills. Multivariate regression analyses were performed. Subgroup analyses based on sequential or concurrent initiation of combination therapy were also conducted. A total of 1,216 patients were matched (ICS/MON = 608; ICS/SAL= 608). Decreased odds of ED visits and/or hospitalizations were observed with ICS/MON (adjusted odds ratio [OR] = 0.58; 95% confidence interval [CI], 0.35- 0.98) versus ICS/SAL. The odds of postindex OCS fills were not different for ICS/MON and ICS/SAL patients (adjusted OR = 1.04; 95% CI, 0.79-1.38). Postindex pharmacy claims for SABAs were significantly higher among ICS/MON patients versus ICS/SAL patients (adjusted relative risk [RR] = 1.33; 95% CI, 1.17-1.52), and this difference remained regardless of prior use or no prior use of ICSs. In subgroup analyses, mean change in SABA fills varied by how combination therapy was initiated, with sequential addition of asthma controllers leading to a reduction in SABA fills in both groups. For patients with concurrent initiation of combination therapy, the odds of ED visits/hospitalizations were significantly lower in patients initiating ICS/MON (adjusted OR = 0.25; 95% CI, 0.08-0.79). In this matched cohort, use of ICS/MON compared with ICS/SAL resulted in similar odds of OCS fills, decreased odds of ED visits and asthmarelated hospitalizations, but higher utilization of SABA.
NSTX-U Control System Upgrades
Erickson, K. G.; Gates, D. A.; Gerhardt, S. P.; ...
2014-06-01
The National Spherical Tokamak Experiment (NSTX) is undergoing a wealth of upgrades (NSTX-U). These upgrades, especially including an elongated pulse length, require broad changes to the control system that has served NSTX well. A new fiber serial Front Panel Data Port input and output (I/O) stream will supersede the aging copper parallel version. Driver support for the new I/O and cyber security concerns require updating the operating system from Redhat Enterprise Linux (RHEL) v4 to RedHawk (based on RHEL) v6. While the basic control system continues to use the General Atomics Plasma Control System (GA PCS), the effort to forwardmore » port the entire software package to run under 64-bit Linux instead of 32-bit Linux included PCS modifications subsequently shared with GA and other PCS users. Software updates focused on three key areas: (1) code modernization through coding standards (C99/C11), (2) code portability and maintainability through use of the GA PCS code generator, and (3) support of 64-bit platforms. Central to the control system upgrade is the use of a complete real time (RT) Linux platform provided by Concurrent Computer Corporation, consisting of a computer (iHawk), an operating system and drivers (RedHawk), and RT tools (NightStar). Strong vendor support coupled with an extensive RT toolset influenced this decision. The new real-time Linux platform, I/O, and software engineering will foster enhanced capability and performance for NSTX-U plasma control.« less
NASA Technical Reports Server (NTRS)
Chamberlin, K.; Clagett, C.; Correll, T.; Gruner, T.; Quinn, T.; Shiflett, L.; Schnurr, R.; Wennersten, M.; Frederick, M.; Fox, S. M.
1993-01-01
The attitude Control Electronics (ACE) Box is the center of the Attitude Control Subsystem (ACS) for the Solar Anomalous and Magnetospheric Particle Explorer (SAMPEX) satellite. This unit is the single point interface for all of the Attitude Control Subsystem (ACS) related sensors and actuators. Commands and telemetry between the SAMPEX flight computer and the ACE Box are routed via a MIL-STD-1773 bus interface, through the use of an 80C85 processor. The ACE Box consists of the flowing electronic elements: power supply, momentum wheel driver, electromagnet driver, coarse sun sensor interface, digital sun sensor interface, magnetometer interface, and satellite computer interface. In addition, the ACE Box also contains an independent Safehold electronics package capable of keeping the satellite pitch axis pointing towards the sun. The ACE Box has dimensions of 24 x 31 x 8 cm, a mass of 4.3 kg, and an average power consumption of 10.5 W. This set of electronics was completely designed, developed, integrated, and tested by personnel at NASA GSFC. SAMPEX was launched on July 3, 1992, and the initial attitude acquisition was successfully accomplished via the analog Safehold electronics in the ACE Box. This acquisition scenario removed the excess body rates via magnetic control and precessed the satellite pitch axis to within 10 deg of the sun line. The performance of the SAMPEX ACS in general and the ACE Box in particular has been quite satisfactory.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and Technology...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and Technology...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and Technology...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... Controller of Imports and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 11011 Indian IC For the “organized” sector, except for computers and related equipment: Directorate... 110011 Indian IC For computers and related electronic items: Department of Electronics, Lok Nayak Bhawan... Controller of Imports and Exports 5, Civic Center Islamabad IC Joint Science Advisor, Ministry of Science and...
Creating a meaningful infection control program: one home healthcare agency's lessons.
Poff, Renee McCoy; Browning, Sarah Via
2014-03-01
Creating a meaningful infection control program in the home care setting proved to be challenging for agency leaders of one hospital-based home healthcare agency. Challenges arose when agency leaders provided infection control (IC) data to the hospital's IC Committee. The IC Section Chief asked for national benchmark comparisons to align home healthcare reporting to that of the hospital level. At that point, it was evident that the home healthcare IC program lacked definition and structure. The purpose of this article is to share how one agency built a meaningful IC program.
Picosecond imaging of signal propagation in integrated circuits
NASA Astrophysics Data System (ADS)
Frohmann, Sven; Dietz, Enrico; Dittrich, Helmar; Hübers, Heinz-Wilhelm
2017-04-01
Optical analysis of integrated circuits (IC) is a powerful tool for analyzing security functions that are implemented in an IC. We present a photon emission microscope for picosecond imaging of hot carrier luminescence in ICs in the near-infrared spectral range from 900 to 1700 nm. It allows for a semi-invasive signal tracking in fully operational ICs on the gate or transistor level with a timing precision of approximately 6 ps. The capabilities of the microscope are demonstrated by imaging the operation of two ICs made by 180 and 60 nm process technology.
NASA Technical Reports Server (NTRS)
De Vries, Dan; Wahr, John M.
1991-01-01
This paper computes the effects of the solid inner core (IC) on the forced nutations and earth tides, and on certain of the earth's rotational normal modes. The theoretical results are extended to include the effects of a solid IC and of nonhydrostatic structure. The presence of the IC is responsible for a new, almost diurnal, prograde normal mode which involves a relative rotation between the IC and fluid outer core about an equatorial axis. It is shown that the small size of the IC's effects on both nutations and tides is a consequence of the fact that the IC's moments of inertia are less than 1/1000 of the entire earth's.
Synthesis of heteroaromatic tropeines and heterogeneous binding to glycine receptors.
Maksay, Gábor; Vincze, Zoltán; Nemes, Péter
2009-10-01
Heteroaromatic carboxylic esters of (nor)tropine were synthesized. Tropine esters displaced [(3)H]strychnine binding to glycine receptors of rat spinal cord with low Hill slopes. Two-site displacement resulted in nanomolar IC(50,1) and micromolar IC(50,2) values, and IC(50,2)/IC(50,1) ratios up to 615 depending on the heteroaromatic rings and N-methyl substitution. Nortropeines displayed high affinity and low heterogeneity. IC(50,1) and IC(50,2) values of tropeines did not correlate suggesting different binding modes/sites. Glycine potentiated only the nanomolar displacement reflecting positive allosteric interactions and potentiation of ionophore function. Affinities of three (nor)tropeines were different for glycine receptors but identical for 5-HT(3) receptors.
Food systems transformations, ultra-processed food markets and the nutrition transition in Asia.
Baker, Phillip; Friel, Sharon
2016-12-03
Attracted by their high economic growth rates, young and growing populations, and increasingly open markets, transnational food and beverage corporations (TFBCs) are targeting Asian markets with vigour. Simultaneously the consumption of ultra-processed foods high in fat, salt and glycaemic load is increasing in the region. Evidence demonstrates that TFBCs can leverage their market power to shape food systems in ways that alter the availability, price, nutritional quality, desirability and ultimately consumption of such foods. This paper describes recent changes in Asian food systems driven by TFBCs in the retail, manufacturing and food service sectors and considers the implications for population nutrition. Market data for each sector was sourced from Euromonitor International for four lower-middle income, three upper-middle income and five high-income Asian countries. Descriptive statistics were used to describe trends in ultra-processed food consumption (2000-2013), packaged food retail distribution channels (1999-2013), 'market transnationalization' defined as the market share held by TFBCs relative to domestic firms (2004-2013), and 'market concentration' defined as the market share and thus market power held by the four leading firms (2004-2013) in each market. Ultra-processed food sales has increased rapidly in most middle-income countries. Carbonated soft drinks was the leading product category, in which Coca-Cola and PepsiCo had a regional oligopoly. Supermarkets, hypermarkets and convenience stores were becoming increasingly dominant as distribution channels for packaged foods throughout the region. Market concentration was increasing in the grocery retail sector in all countries. Food service sales are increasing in all countries led by McDonalds and Yum! Brands. However, in all three sectors TFBCs face strong competition from Asian firms. Overall, the findings suggest that market forces are likely to be significant but variable drivers of Asia's nutrition transition. The carbonated soft drink market is the most highly concentrated and likely to be most harmful to population nutrition. The grocery retail sector is, in terms of increasing market concentration and thus market power, likely to be the most important driver of ongoing food systems change and ultra-processed food sales in the region. Given it's rapid growth, the food service sector will also contribute significantly to ongoing dietary change.
Very Low Head Turbine Deployment in Canada
NASA Astrophysics Data System (ADS)
Kemp, P.; Williams, C.; Sasseville, Remi; Anderson, N.
2014-03-01
The Very Low Head (VLH) turbine is a recent turbine technology developed in Europe for low head sites in the 1.4 - 4.2 m range. The VLH turbine is primarily targeted for installation at existing hydraulic structures to provide a low impact, low cost, yet highly efficient solution. Over 35 VLH turbines have been successfully installed in Europe and the first VLH deployment for North America is underway at Wasdell Falls in Ontario, Canada. Deployment opportunities abound in Canada with an estimated 80,000 existing structures within North America for possible low-head hydro development. There are several new considerations and challenges for the deployment of the VLH turbine technology in Canada in adapting to the hydraulic, environmental, electrical and social requirements. Several studies were completed to determine suitable approaches and design modifications to mitigate risk and confirm turbine performance. Diverse types of existing weirs and spillways pose certain hydraulic design challenges. Physical and numerical modelling of the VLH deployment alternatives provided for performance optimization. For this application, studies characterizing the influence of upstream obstacles using water tunnel model testing as well as full-scale prototype flow dynamics testing were completed. A Cold Climate Adaptation Package (CCA) was developed to allow year-round turbine operation in ice covered rivers. The CCA package facilitates turbine extraction and accommodates ice forces, frazil ice, ad-freezing and cold temperatures that are not present at the European sites. The Permanent Magnet Generator (PMG) presents some unique challenges in meeting Canadian utility interconnection requirements. Specific attention to the frequency driver control and protection requirements resulted in a driver design with greater over-voltage capability for the PMG as well as other key attributes. Environmental studies in Europe included fish friendliness testing comprised of multiple in-river live passage tests for a wide variety of fish species. Latest test results indicate fish passage survivability close to 100%. Further fish studies are planned in Canada later this year. Successful deployment must meet societal requirements to gain community acceptance and public approval. Aesthetics considerations include low noise, disguised control buildings and vigilant turbine integration into the low profile existing structures. The resulting design was selected for deployment at existing historic National Park waterway structures. The integration of all of these design elements permits the successful deployment of the VLH turbine in Canada.
Post-Inhaled Corticosteroid Pulmonary Tuberculosis Increases Lung Cancer in Patients with Asthma
Lin, Frank Cheau-Feng; Nfor, Oswald Ndi; Jhang, Kai-Ming; Ku, Wen-Yuan; Ho, Chien-Chang; Lung, Chia-Chi; Pan, Hui-Hsien; Wu, Min-Chen; Wu, Ming-Fang; Liaw, Yung-Po
2016-01-01
Purpose To evaluate the association between post-inhaled corticosteroid (ICS) pulmonary tuberculosis (TB), pneumonia and lung cancer in patients with asthma. Methods The study samples were collected from the National Health Insurance Database. Asthmatic patients who were first-time users of ICS between 2003 and 2005 were identified as cases. For each case, 4 control individuals were randomly matched for sex, age and date of ICS use. Cases and matched controls were followed up until the end of 2010. Cox proportional hazard regression was used to determine the hazard ratio for pulmonary infections and lung cancer risk in the ICS users and non-users. Results A total of 10,904 first-time users of ICS were matched with 43,616 controls. The hazard ratios for lung cancer were: 2.52 (95% confidence interval [CI], 1.22–5.22; p = 0.012) for individuals with post-ICS TB, 1.28 (95%CI, 0.73–2.26; p = 0.389) for post-ICS pneumonia, 2.31(95%CI, 0.84–6.38; p = 0.105) for post-ICS pneumonia+TB, 1.08 (95%CI, 0.57–2.03; p = 0.815) for TB, 0.99 (95%CI, 0.63–1.55; p = 0.970) for pneumonia, and 0.32 (95%CI, 0.05–2.32; p = 0.261) for pneumonia+ TB, respectively. Conclusions Post-ICS TB increased lung cancer risk in patients with asthma. Because of the high mortality associated with lung cancer, screening tests are recommended for patients with post-ICS TB. PMID:27448321
Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago
2016-02-01
The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated.Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial).A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non-HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items.
Validation of the Intelligibility in Context Scale for Jamaican Creole-Speaking Preschoolers.
Washington, Karla N; McDonald, Megan M; McLeod, Sharynne; Crowe, Kathryn; Devonish, Hubert
2017-08-15
To describe validation of the Intelligibility in Context Scale (ICS; McLeod, Harrison, & McCormack, 2012a) and ICS-Jamaican Creole (ICS-JC; McLeod, Harrison, & McCormack, 2012b) in a sample of typically developing 3- to 6-year-old Jamaicans. One-hundred and forty-five preschooler-parent dyads participated in the study. Parents completed the 7-item ICS (n = 145) and ICS-JC (n = 98) to rate children's speech intelligibility (5-point scale) across communication partners (parents, immediate family, extended family, friends, acquaintances, strangers). Preschoolers completed the Diagnostic Evaluation of Articulation and Phonology (DEAP; Dodd, Hua, Crosbie, Holm, & Ozanne, 2006) in English and Jamaican Creole to establish speech-sound competency. For this sample, we examined validity and reliability (interrater, test-rest, internal consistency) evidence using measures of speech-sound production: (a) percentage of consonants correct, (b) percentage of vowels correct, and (c) percentage of phonemes correct. ICS and ICS-JC ratings showed preschoolers were always (5) to usually (4) understood across communication partners (ICS, M = 4.43; ICS-JC, M = 4.50). Both tools demonstrated excellent internal consistency (α = .91), high interrater, and test-retest reliability. Significant correlations between the two tools and between each measure and language-specific percentage of consonants correct, percentage of vowels correct, and percentage of phonemes correct provided criterion-validity evidence. A positive correlation between the ICS and age further strengthened validity evidence for that measure. Both tools show promising evidence of reliability and validity in describing functional speech intelligibility for this group of typically developing Jamaican preschoolers.
Davidsen, Jesper Rømhild; Søndergaard, Jens; Hallas, Jesper; Siersted, Hans Christian; Lykkegaard, Jesper; Andersen, Morten
2010-12-01
This population-based longitudinal study aimed to investigate trends in use of inhaled corticosteroids (ICS) and determinants of ICS use in young Danish adults with asthma. 106 757 users, aged 18-44 years, of anti-asthmatic drugs were identified in the Danish Register of Medical Product Statistics during 1997-2006. One year prevalences of ICS use were calculated in categories of gender, age, and annual consumption of inhaled beta-2-agonists (IBA) in defined daily doses (DDD) per year. Determinants of ICS use were estimated by logistic regression models. The one year prevalence of ICS use was constant, approximately 64%, during 1997-2000. An annual increase was observed from 67% in 2001 to 77% in 2006. This trend also existed when stratifying on gender, age and IBA use. Using 1997 as baseline, the adjusted odds ratios (ORs) of ICS use in 2000 was 0.98 (95% CI 0.96-1.01) compared to 1.12 (95% CI 1.09-1.15) in 2001, and 1.81 (95% CI 1.75-1.87) in 2006. Other determinants of high ICS use were female gender, young age, and high annual IBA consumption. Among those using at least 400 DDD of IBA per year (corresponding to 4.4 powder inhalations daily), nearly 20% had no ICS prescriptions in 2006. Treatment with ICS among young Danish adult asthmatics has increased since 2001. This apparent improvement was associated with the introduction of fixed dose combination inhalers with ICS and inhaled long-acting beta-2-agonists. However, there is still room for improvement. Copyright © 2010 Elsevier Ltd. All rights reserved.
Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago
2016-01-01
Abstract The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated. Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial). A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non–HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items. PMID:26844471
Africa, Lia A. A.; Murphy, Erin R.; Egan, Nicholas R.; Wigley, Amanda F.; Wing, Helen J.
2011-01-01
Actin-based motility is central to the pathogenicity of the intracellular bacterial pathogen Shigella. Two Shigella outer membrane proteins, IcsA and IcsP, are required for efficient actin-based motility in the host cell cytoplasm, and the genes encoding both proteins are carried on the large virulence plasmid. IcsA triggers actin polymerization on the surface of the bacterium, leading to the formation of an actin tail that allows both intra- and intercellular spread. IcsP, an outer membrane protease, modulates the amount and distribution of the IcsA protein on the bacterial surface through proteolytic cleavage of IcsA. Transcription of icsP is increased in the presence of VirB, a DNA-binding protein that positively regulates many genes carried on the large virulence plasmid. In Shigella dysenteriae, the small regulatory RNA RyhB, which is a member of the iron-responsive Fur regulon, suppresses several virulence-associated phenotypes by downregulating levels of virB in response to iron limitation. Here we show that the Fur/RyhB regulatory pathway downregulates IcsP levels in response to low iron concentrations in Shigella flexneri and that this occurs at the level of transcription through the RyhB-dependent regulation of VirB. These observations demonstrate that in Shigella species the Fur/RyhB regulatory pathway provides a mechanism to finely tune the expression of icsP in response to the low concentrations of free iron predicted to be encountered within colonic epithelial cells. PMID:21859852
Reiter, Christoph; Fröhlich, Tony; Gruber, Lisa; Hutterer, Corina; Marschall, Manfred; Voigtländer, Cornelia; Friedrich, Oliver; Kappes, Barbara; Efferth, Thomas; Tsogoeva, Svetlana B
2015-09-01
New pharmaceutically active compounds can be obtained by modification of existing drugs to access more effective agents in the wake of drug resistance amongst others. To achieve this goal the concept of hybridization was established during the last decade. We employed this concept by coupling two artemisinin-derived precursors to obtain dimers or trimers with increased in vitro activity against Plasmodiumfalciparum 3D7 strain, leukemia cells (CCRF-CEM and multidrug-resistant subline CEM/ADR5000) and human cytomegalovirus (HCMV). Dimer 4 (IC50 of 2.6 nM) possess superior antimalarial activity compared with its parent compound artesunic acid(3) (IC50 of 9.0 nM). Dimer5 and trimers6 and 7 display superior potency against both leukemia cell lines (IC50 up to 0.002 μM for CCRF-CEM and IC50 up to 0.20 μM for CEM/ADR5000) and are even more active than clinically used doxorubicin (IC50 1.61 μM for CEM/ADR5000). With respect to anti-HCMV activity, trimer6 is the most efficient hybrid (IC50 0.04 μM) outperforming ganciclovir (IC50 2.6 μM), dihydroartemisinin(IC50 >10 μM) and artesunic acid (IC50 3.8 μM). Copyright © 2015 Elsevier Ltd. All rights reserved.
Byun, Youngjae; Rodriguez, Katia; Han, Jung H; Kim, Young Teck
2015-11-01
The effects of the incorporation of PLA-β-cyclodextrin-inclusion complex (IC) and β-cyclodextrin (β-CD) on biopolyester PLA films were investigated. Thermal stability, surface morphology, barrier, and mechanical properties of the films were measured at varying IC (1, 3, 5, and 7%) and β-CD (1 and 5%) concentrations. The PLA-IC-composite films (IC-PLA-CFs) showed uniform morphological structure, while samples containing β-CD (β-CD-PLA-CFs) showed high agglomeration of β-CD due to poor interfacial interaction between β-CD and PLA moieties. According to the thermal property analysis, the 5% IC-PLA-CFs showed 6.6 times lower dimensional changes (6.5%) at the temperature range of 20-80°C than that of pure PLA film (43.0%). The increase of IC or β-CD content in the PLA-composite films shifted the glass transition and crystallization temperature to higher temperature regions. The crystallinity of both composite films improved by increasing IC or β-CD content. Both composite films had higher oxygen and water vapor permeability as IC or β-CD content increased in comparison to pure PLA film. All the composite films had less flexibility and lower tensile strength than the pure PLA film. In conclusion, this study shows that the IC technique is valuable to improve the thermal expansion stability of PLA-based films. Published by Elsevier B.V.
Alesso, C A; Discola, K F; Monteiro, G
2015-09-01
In the yeast Saccharomyces cerevisiae, many genes are involved in the uptake, transport, storage and detoxification of copper. Large scale studies have noted that deletion of the gene ICS3 increases sensitivity to copper, Sortin 2 and acid exposure. Here, we report a study on the Δics3 strain, in which ICS3 is related to copper homeostasis, affecting the intracellular accumulation of this metal. This strain is sensitive to hydrogen peroxide and copper exposure, but not to other tested transition metals. At pH 6.0, the Δics3 strain accumulates a larger amount of intracellular copper than the wild-type strain, explaining the sensitivity to oxidants in this condition. Unexpectedly, sensitivity to copper exposure only occurs in acidic conditions. This can be explained by the fact that the exposure of Δics3 cells to high copper concentrations at pH 4.0 results in over-accumulation of copper and iron. Moreover, the expression of ICS3 increases in acidic pH, and this is correlated with CCC2 gene expression, since both genes are regulated by Rim101 from the pH regulon. CCC2 is also upregulated in Δics3 in acidic pH. Together, these data indicate that ICS3 is involved in copper homeostasis and is dependent on extracellular pH. Copyright © 2015 Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... NUCLEAR REGULATORY COMMISSION Advisory Committee on Reactor Safeguards (ACRS); Meeting of the ACRS Subcommittee on Digital I&C Systems The ACRS Subcommittee on Digital Instrumentation and Controls (I&C) Systems...: Wednesday, September 8, 2010--8:30 a.m. until 12 p.m. The Subcommittee will review Digital I&C Interim Staff...
Using IC-ICP-MS and IC-ESI-MS/MS, an unknown arsenical compound in mollusks has been identified as a new arsine sulfide containing analog of a known arsenosugar and is referred to as As(498). This species has been observed in four separate shellfish species following a mild metha...
On Patarin's Attack against the lIC Scheme
NASA Astrophysics Data System (ADS)
Ogura, Naoki; Uchiyama, Shigenori
In 2007, Ding et al. proposed an attractive scheme, which is called the l-Invertible Cycles (lIC) scheme. lIC is one of the most efficient multivariate public-key cryptosystems (MPKC); these schemes would be suitable for using under limited computational resources. In 2008, an efficient attack against lIC using Gröbner basis algorithms was proposed by Fouque et al. However, they only estimated the complexity of their attack based on their experimental results. On the other hand, Patarin had proposed an efficient attack against some multivariate public-key cryptosystems. We call this attack Patarin's attack. The complexity of Patarin's attack can be estimated by finding relations corresponding to each scheme. In this paper, we propose an another practical attack against the lIC encryption/signature scheme. We estimate the complexity of our attack (not experimentally) by adapting Patarin's attack. The attack can be also applied to the lIC- scheme. Moreover, we show some experimental results of a practical attack against the lIC/lIC- schemes. This is the first implementation of both our proposed attack and an attack based on Gröbner basis algorithm for the even case, that is, a parameter l is even.
Maharaj, Payal D.; Bolling, Bethany G.; Anishchenko, Michael; Reisen, William K.; Brault, Aaron C.
2014-01-01
St. Louis encephalitis virus (SLEV) has shown greater susceptibility to oral infectivity than West Nile virus (WNV) in Culex mosquitoes. To identify the viral genetic elements that modulate these disparate phenotypes, structural chimeras (WNV–pre-membrane [prM] and envelope [E] proteins [prME]/SLEV.IC (infectious clone) and SLEV-prME/WNV.IC) were constructed in which two of the structural proteins, the prM and E, were interchanged between viruses. Oral dose–response assessment with the chimeric/parental WNV and SLEV was performed to characterize the infection phenotypes in Culex mosquitoes by artificial blood meals. The median infectious dose required to infect 50% of Cx. quinquefasciatus with WNV was indistinguishable from that of the SLEV-prME/WNV.IC chimeric virus. Similarly, SLEV and WNV-prME/SLEV.IC virus exhibited an indistinguishable oral dose–response relationship in Cx. quinquefasciatus. Infection rates for WNV.IC and SLEV-prME/WNV.IC were significantly lower than SLEV.IC and WNV-prME/SLEV.IC infection rates. These results indicated that WNV and SLEV oral infectivities are not mediated by genetic differences within the prM and E proteins. PMID:25157120
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, A.N.; Soden, J.M.
1998-12-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits are disclosed. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal. 4 figs.
TIF-IC, a factor involved in both transcription initiation and elongation of RNA polymerase I.
Schnapp, G; Schnapp, A; Rosenbauer, H; Grummt, I
1994-09-01
We have characterized a transcription factor from Ehrlich ascites cells that is required for ribosomal gene transcription by RNA polymerase I (Pol I). This factor, termed TIF-IC, has a native molecular mass of 65 kDa, associates with Pol I, and is required both for the assembly of Sarkosyl-resistant initiation complexes and for the formation of the first internucleotide bonds. In addition to its function in transcription initiation, TIF-IC also plays a role in elongation of nascent RNA chains. At suboptimal levels of TIF-IC, transcripts with heterogeneous 3' ends are formed which are chased into full-length transcripts by the addition of more TIF-IC. Moreover, on a tailed template, which allows initiation in the absence of auxiliary factors, TIF-IC was found to stimulate the overall rate of transcription elongation and suppress pausing of Pol I. Thus TIF-IC appears to serve a function similar to the Pol II-specific factor TFIIF which is required for Pol II transcription initiation and elongation.
Araya, Romina E.; Jury, Jennifer; Bondar, Constanza
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen. PMID:24915573
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, Ann N.; Soden, Jerry M.
1998-01-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal.
Araya, Romina E; Jury, Jennifer; Bondar, Constanza; Verdu, Elena F; Chirdo, Fernando G
2014-01-01
Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen.
Sliter, Michael T; Pui, Shuang Yueh; Sliter, Katherine A; Jex, Steve M
2011-10-01
Interpersonal conflict (IC) at work is a frequently experienced type of workplace mistreatment that has been linked to a host of negative workplace outcomes. Previous research has shown that IC can have differential effects based on source, but this has not yet been investigated in terms of customer IC versus coworker IC. To remedy this oversight in the literature, we used a multimethod, multitime point design to compare IC from customers and coworkers experienced by 75 call center employees. Primarily, we investigated burnout, physical health symptoms, and task performance. Results indicated that customer IC was more strongly related to both personal and organizational outcomes. Additionally, trait anger was investigated as a moderator of these relationships, and the results indicated that people who are easy to anger may be more likely to experience negative effects as a result of customer IC. Implications of these findings, limitations, and areas for future research are discussed. (PsycINFO Database Record (c) 2011 APA, all rights reserved).
Meng, Xiaoyan; Ni, Cheng; Shen, Yaqi; Hu, Xuemei; Chen, Xiao; Li, Zhen; Hu, Daoyu
2017-01-01
To investigate the value of quantitative analysis in dual energy spectral computed tomography (DESCT) for differentiating malignant gastric mucosal lesions from benign gastric mucosal lesions (including gastric inflammation [GI] and normal gastric mucosa [NGM]). This study was approved by the ethics committee, and all patients provided written informed consent. A total of 161 consecutive patients (63 with gastric cancer [GC], 48 with GI, and 50 with NGM) who underwent dual-phase contrast enhanced DESCT scans in the arterial phase (AP) and portal venous phase (PVP) were included in this study. Iodine concentration (IC) in lesions was derived from the iodine-based material-decomposition images and normalized to that in the aorta to obtain normalized IC (nIC). The ratios of IC and nIC between the AP and PVP were calculated. Diagnostic confidence for GC and GI was evaluated with reviewing the features including gastric wall thickness, focal, and eccentric on the conventional polychromatic images. All statistical analyses were performed by using statistical software SPSS 17.0 (SPSS, Chicago, IL). IC and nIC in GC differed significantly from those in GI and NGM, except for nICAP in comparing GC with GI. Mean nIC values of GC (0.18 ± 0.06 in AP and 0.62 ± 0.16 in PVP) were significantly higher than that of NGM (0.12 ± 0.03 in AP and 0.37 ± 0.08 in PVP) (all P < 0.05). There was also significant difference for IC values in GC, GI, and NGM (24.19 ± 8.27, 19.07 ± 5.82, and 13.61 ± 2.52 mg/mL, respectively, in AP and 28.00 ± 7.01, 24.66 ± 6.55, and 16.94 ± 3.06 mg/mL, respectively, in PVP). Based on Receiver Operating Characteristic Curve analysis, nIC and IC in PVP had high sensitivities of 88.89% and 90.48%, respectively, in differentiating GC from NGM, while the sensitivities were 71.43% and 88.89% during AP. Ratios IC and nIC ratios did not provide adequate diagnostic accuracy with their area under curves less than 0.65. With the conventional features, the diagnostic accuracies for GC and GI were 75.0% and 98.0%, respectively. Quantitative analysis of DESCT imaging parameters for gastric mucosa, such as nIC and IC, is useful for differentiating malignant from benign gastric mucosal lesions.
A randomized placebo-controlled phase II study of a Pseudomonas vaccine in ventilated ICU patients.
Rello, Jordi; Krenn, Claus-Georg; Locker, Gottfried; Pilger, Ernst; Madl, Christian; Balica, Laura; Dugernier, Thierry; Laterre, Pierre-Francois; Spapen, Herbert; Depuydt, Pieter; Vincent, Jean-Louis; Bogár, Lajos; Szabó, Zsuzsanna; Völgyes, Barbara; Máñez, Rafael; Cakar, Nahit; Ramazanoglu, Atilla; Topeli, Arzu; Mastruzzo, Maria A; Jasovich, Abel; Remolif, Christian G; Del Carmen Soria, Liliana; Andresen Hernandez, Max A; Ruiz Balart, Carolina; Krémer, Ildikó; Molnár, Zsolt; von Sonnenburg, Frank; Lyons, Arthur; Joannidis, Michael; Burgmann, Heinz; Welte, Tobias; Klingler, Anton; Hochreiter, Romana; Westritschnig, Kerstin
2017-02-04
Currently, no vaccine against Pseudomonas is available. IC43 is a new, recombinant, protein (OprF/I)-based vaccine against the opportunistic pathogen, Pseudomonas aeruginosa, a major cause of serious hospital-acquired infections. IC43 has proven immunogenicity and tolerability in healthy volunteers, patients with burns, and patients with chronic lung diseases. In order to assess the immunogenicity and safety of IC43 in patients who are most at risk of acquiring Pseudomonas infections, it was evaluated in mechanically ventilated ICU patients. We conducted a randomized, placebo-controlled, partially blinded study in mechanically ventilated ICU patients. The immunogenicity of IC43 at day 14 was determined as the primary endpoint, and safety, efficacy against P. aeruginosa infections, and all-cause mortality were evaluated as secondary endpoints. Vaccinations (100 μg or 200 μg IC43 with adjuvant, or 100 μg IC43 without adjuvant, or placebo) were given twice in a 7-day interval and patients were followed up for 90 days. Higher OprF/I IgG antibody titers were seen at day 14 for all IC43 groups versus placebo (P < 0.0001). Seroconversion (≥4-fold increase in OprF/I IgG titer from days 0 to 14) was highest with 100 μg IC43 without adjuvant (80.6%). There were no significant differences in P. aeruginosa infection rates, with a low rate of invasive infections (pneumonia or bacteremia) in the IC43 groups (11.2-14.0%). Serious adverse events (SAEs) considered possibly related to therapy were reported by 2 patients (1.9%) in the group of 100 µg IC43 with adjuvant. Both SAEs resolved and no deaths were related to study treatment. Local tolerability symptoms were mild and rare (<5% of patients), a low rate of treatment-related treatment-emergent adverse events (3.1-10.6%) was observed in the IC43 groups. This phase II study has shown that IC43 vaccination of ventilated ICU patients produced a significant immunogenic effect. P. aeruginosa infection rates did not differ significantly between groups. In the absence of any difference in immune response following administration of 100 μg IC43 without adjuvant compared with 200 μg IC43 with adjuvant, the 100 μg dose without adjuvant was considered for further testing of its possible benefit of improved outcomes. There were no safety or mortality concerns. ClinicalTrials.gov, NCT00876252 . Registered on 3 April 2009.
Novel inter-crystal scattering event identification method for PET detectors
NASA Astrophysics Data System (ADS)
Lee, Min Sun; Kang, Seung Kwan; Lee, Jae Sung
2018-06-01
Here, we propose a novel method to identify inter-crystal scattering (ICS) events from a PET detector that is even applicable to light-sharing designs. In the proposed method, the detector observation was considered as a linear problem and ICS events were identified by solving this problem. Two ICS identification methods were suggested for solving the linear problem, pseudoinverse matrix calculation and convex constrained optimization. The proposed method was evaluated based on simulation and experimental studies. For the simulation study, an 8 × 8 photo sensor was coupled to 8 × 8, 10 × 10 and 12 × 12 crystal arrays to simulate a one-to-one coupling and two light-sharing detectors, respectively. The identification rate, the rate that the identified ICS events correctly include the true first interaction position and the energy linearity were evaluated for the proposed ICS identification methods. For the experimental study, a digital silicon photomultiplier was coupled with 8 × 8 and 10 × 10 arrays of 3 × 3 × 20 mm3 LGSO crystals to construct the one-to-one coupling and light-sharing detectors, respectively. Intrinsic spatial resolutions were measured for two detector types. The proposed ICS identification methods were implemented, and intrinsic resolutions were compared with and without ICS recovery. As a result, the simulation study showed that the proposed convex optimization method yielded robust energy estimation and high ICS identification rates of 0.93 and 0.87 for the one-to-one and light-sharing detectors, respectively. The experimental study showed a resolution improvement after recovering the identified ICS events into the first interaction position. The average intrinsic spatial resolutions for the one-to-one and light-sharing detector were 1.95 and 2.25 mm in the FWHM without ICS recovery, respectively. These values improved to 1.72 and 1.83 mm after ICS recovery, respectively. In conclusion, our proposed method showed good ICS identification in both one-to-one coupling and light-sharing detectors. We experimentally validated that the ICS recovery based on the proposed identification method led to an improved resolution.
Wang, Jun; Kang, Tony; Arepalli, Chesnal; Barrett, Sarah; O'Connell, Tim; Louis, Luck; Nicolaou, Savvakis; McLaughlin, Patrick
2015-06-01
The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p < 0.001), spleen (19.33 IC vs. 20.83 DC, 7.20% decrease, p = 0.02), and right renal cortex (20.28 IC vs. 22.98 DC, 11.7% decrease, p = 0.005). Mean obstructing ureteric calculi size was not significantly different when comparison was made between full-dose and half-dose images, regardless of detector type (p > 0.05 for all comparisons). Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater at half-radiation dose indicating that the benefits of using novel IC detectors are greater in low and ultra-low-dose CT imaging.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-01
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. IC10-6-000 and IC10-6Q-000] Commission Information Collection Activities (FERC Form Nos. 6 and 6-Q); Comment Request; Extensions January... to Docket Nos. IC10-6-000 and IC10-6Q-000. For comments that only pertain to one of the collections...