Sample records for drop counting device

  1. An active drop counting device using condenser microphone for superheated emulsion detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Mala; Marick, C.; Kanjilal, D.

    2008-11-15

    An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrummore » of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.« less

  2. An active drop counting device using condenser microphone for superheated emulsion detector

    NASA Astrophysics Data System (ADS)

    Das, Mala; Arya, A. S.; Marick, C.; Kanjilal, D.; Saha, S.

    2008-11-01

    An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of C252f fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of C252f. Frequency analysis of the detected signals was also carried out.

  3. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    PubMed

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  4. 25 CFR 542.3 - How do I comply with this part?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... provide for drop/count observations, inclusive of hard drop/count, soft drop/count and currency acceptor... observations would be unexpected, the hard count and soft count rooms may be entered simultaneously... should be included in the Agreed-Upon Procedures report transmitted to the Commission. (4) Report Format...

  5. HIV Patients Drop Out in Indonesia: Associated Factors and Potential Productivity Loss.

    PubMed

    Siregar, Adiatma Ym; Pitriyan, Pipit; Wisaksana, Rudi

    2016-07-01

    this study reported various factors associated with a higher probability of HIV patients drop out, and potential productivity loss due to HIV patients drop out. we analyzed data of 658 HIV patients from a database in a main referral hospital in Bandung city, West Java, Indonesia from 2007 to 2013. First, we utilized probit regression analysis and included, among others, the following variables: patients' status (active or drop out), CD4 cell count, TB and opportunistic infection (OI), work status, sex, history of injecting drugs, and support from family and peers. Second, we used the drop out data from our database and CD 4 cell count decline rate from another study to estimate the productivity loss due to HIV patients drop out. lower CD4 cell count was associated with a higher probability of drop out. Support from family/peers, living with family, and diagnosed with TB were associated with lower probability of drop out. The productivity loss at national level due to treatment drop out (consequently, due to CD4 cell count decline) can reach US$365 million (using average wage). first, as lower CD 4 cell count was associated with higher probability of drop out, we recommend (to optimize) early ARV initiation at a higher CD 4 cell count, involving scaling up HIV service at the community level. Second, family/peer support should be further emphasized to further ensure treatment success. Third, dropping out from ART will result in a relatively large productivity loss.

  6. 25 CFR 543.17 - What are the minimum internal control standards for drop and count?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...

  7. 25 CFR 543.17 - What are the minimum internal control standards for drop and count?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false What are the minimum internal control standards for drop and count? 543.17 Section 543.17 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS FOR CLASS II GAMING § 543.17 What are the minimum internal control standards for drop and count?...

  8. 25 CFR 542.21 - What are the minimum internal control standards for drop and count for Tier A gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... locked table game drop boxes shall be removed from the tables by a person independent of the pit shift... boxes shall be performed by a minimum of two persons, at least one of whom is independent of the pit... count team shall be independent of transactions being reviewed and counted. The count team shall be...

  9. 25 CFR 542.41 - What are the minimum internal control standards for drop and count for Tier C gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... locked table game drop boxes shall be removed from the tables by a person independent of the pit shift... boxes shall be performed by a minimum of two persons, at least one of whom is independent of the pit.... (4) The count team shall be independent of transactions being reviewed and counted. The count team...

  10. Simple, robust storage of drops and fluids in a microfluidic device.

    PubMed

    Boukellal, Hakim; Selimović, Seila; Jia, Yanwei; Cristobal, Galder; Fraden, Seth

    2009-01-21

    We describe a single microfluidic device and two methods for the passive storage of aqueous drops in a continuous stream of oil without any external control but hydrodynamic flow. Advantages of this device are that it is simple to manufacture, robust under operation, and drops never come into contact with each other, making it unnecessary to stabilize drops against coalescence. In one method the device can be used to store drops that are created upstream from the storage zone. In the second method the same device can be used to simultaneously create and store drops from a single large continuous fluid stream without resorting to the usual flow focusing or T-junction drop generation processes. Additionally, this device stores all the fluid introduced, including the first amount, with zero waste. Transport of drops in this device depends, however, on whether or not the aqueous drops wet the device walls. Analysis of drop transport in these two cases is presented. Finally, a method for extraction of the drops from the device is also presented, which works best when drops do not wet the walls of the chip.

  11. Disdrometer and Tipping Bucket Rain Gauge Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomew. MJ

    2009-12-01

    The Distromet disdrometer model RD-80 and NovaLynx tipping bucket rain gauge model 260-2500E-12 are two devices deployed a few meters apart to measure the character and amount of liquid precipitation. The main purpose of the disdrometer is to measure drop size distribution, which it does over 20 size classes from 0.3 mm to 5.4 mm. The data from both instruments can be used to determine rain rate. The disdrometer results can also be used to infer several properties including drop number density, radar reflectivity, liquid water content, and energy flux. Two coefficients, N0 and Λ, from an exponential fit betweenmore » drop diameter and drop number density, are routinely calculated. Data are collected once a minute. The instruments make completely different kinds of measurements. Rain that falls on the disdrometer sensor moves a plunger on a vertical axis. The disdrometer transforms the plunger motion into electrical impulses whose strength is proportional to drop diameter. The rain gauge is the conventional tipping bucket type. Each tip collects an amount equivalent to 0.01 in. of water, and each tip is counted by a data acquisition system anchored by a Campbell CR1000 data logger.« less

  12. Effects of probiotic drop containing Lactobacillus rhamnosus, Bifidobacterium infantis, and Lactobacillus reuteri on salivary Streptococcus mutans and Lactobacillus levels

    PubMed Central

    Tehrani, Maryam Hajnorouzali; Akhlaghi, Najmeh; Talebian, Leila; Emami, Jaber; Keyhani, Siamak Etzad

    2016-01-01

    Aims: The aim of the present study was to evaluate the effect of a probiotic drop containing Lactobacillus rhamnosus, Bifidobacterium infantis, and Lactobacillus reuteri on salivary counts of Streptococcus mutans (SM) and Lactobacillus (LB) in children 3–6 years of age. Settings and Design: Sixty-one healthy children were randomly allocated into two parallel blocks in this double-blind, randomized controlled trial (IRCT2014120320202N1) from May to June 2015. Subjects and Methods: Finally 53 participants consumed five drops of placebo (n = 23) or probiotic (n = 30) every night for 2 weeks. Before intervention and 1 day after completion of the intervention, unstimulated salivary samples were collected, and microbiologic evaluations were carried out. Statistical Analysis: Data were analyzed with descriptive statistical methods Wilcoxon signed ranks, Mann–Whitney, and logistic regression. Results: SM level decreased significantly in probiotic group after intervention (P = 0.045), and there were significant differences in salivary SM counts after intervention between two groups (P = 0.04). In probiotic group, LB counts decreased significantly after intervention (P = 0.048); however, there were no significant differences between two groups (P = 0.216). Conclusions: Use of this probiotic drop decreased salivary counts of SM; however, LB counts did not change. In addition, use of the drop in children with higher salivary counts appeared to be more effective. PMID:27994413

  13. Differential white cell count by centrifugal microfluidics.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less

  14. 25 CFR 542.31 - What are the minimum internal control standards for drop and count for Tier B gaming operations?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... locked table game drop boxes shall be removed from the tables by a person independent of the pit shift... boxes shall be performed by a minimum of two persons, at least one of whom is independent of the pit... digital record, within seven (7) days by an employee independent of the count. (ii) [Reserved] (2) Count...

  15. Raindrop intervalometer

    NASA Astrophysics Data System (ADS)

    van de Giesen, Nicolaas; Hut, Rolf; ten Veldhuis, Marie-claire

    2017-04-01

    If one can assume that drop size distributions can be effectively described by a generalized gamma function [1], one can estimate this function on the basis of the distribution of time intervals between drops hitting a certain area. The arrival of a single drop is relatively easy to measure with simple consumer devices such as cameras or piezoelectric elements. Here we present an open-hardware design for the electronics and statistical processing of an intervalometer that measures time intervals between drop arrivals. The specific hardware in this case is a piezoelectric element in an appropriate housing, combined with an instrumentation op-amp and an Arduino processor. Although it would not be too difficult to simply register the arrival times of all drops, it is more practical to only report the main statistics. For this purpose, all intervals below a certain threshold during a reporting interval are summed and counted. We also sum the scaled squares, cubes, and fourth powers of the intervals. On the basis of the first four moments, one can estimate the corresponding generalized gamma function and obtain some sense of the accuracy of the underlying assumptions. Special attention is needed to determine the lower threshold of the drop sizes that can be measured. This minimum size often varies over the area being monitored, such as is the case for piezoelectric elements. We describe a simple method to determine these (distributed) minimal drop sizes and present a bootstrap method to make the necessary corrections. Reference [1] Uijlenhoet, R., and J. N. M. Stricker. "A consistent rainfall parameterization based on the exponential raindrop size distribution." Journal of Hydrology 218, no. 3 (1999): 101-127.

  16. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual blood cell counting device. 864.6160...

  17. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual blood cell counting device. 864.6160...

  18. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual blood cell counting device. 864.6160...

  19. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual blood cell counting device. 864.6160...

  20. 21 CFR 864.6160 - Manual blood cell counting device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general...

  1. Use of the Heimlich valve in a compact autotransfusion device.

    PubMed

    Schweitzer, E J; Hauer, J M; Swan, K G; Bresch, J R; Harmon, J W; Graeber, G M

    1987-05-01

    A compact device which evacuates blood from a hemothorax and facilitates rapid autotransfusion was evaluated in dogs. Experimental hemothorax was established surgically by incising the internal mammary artery through a thoracotomy with the animals under general anesthesia. Postoperatively the blood was drained by one of two methods. In the Heimlich valve group (n = 5), blood was drained by a chest tube through a one-way flutter valve into a collapsible plastic bag. In the Sorenson group (n = 5), blood was drained by a chest tube into the Sorenson Autotransfusion System. Blood from these two groups was then autotransfused. In the control group (n = 5), the drained blood was not autotransfused. Results showed no statistical difference between the two autotransfusion groups in the volume of blood collected, circulating fibrinogen levels, platelet counts, stroma-free hemoglobin levels, prothrombin time, or 51Cr-labeled RBC survival. There was a significant drop in the circulating platelet count, which returned to normal by 24 hours, in both groups of dogs which were autotransfused. We conclude that autotransfusion of blood collected by a compact device which utilizes a Heimlich valve and requires no suction is similar to using the Sorenson Autotransfusion System. It may be safe to use the Heimlich valve to collect blood for autotransfusion in clinical situations, where its qualities of simplicity, portability and a minimum requirement for storage space are desirable.

  2. Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.

    PubMed

    Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M

    2017-12-01

    A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.

  3. Radiographic evaluation of vessel count and density with quantitative magnetic resonance imaging during external breast expansion in Asian women: A prospective clinical trial.

    PubMed

    Myung, Yujin; Kwon, Heeyeon; Pak, Changsik; Lee, Hobin; Jeong, Jae Hoon; Heo, Chan Yeong

    2016-12-01

    Breast augmentation with fat transfer does not bear the risks associated with silicone implantation. The method can potentially be especially useful in Asian women, who often reject augmentation mammoplasty with implants. This prospective clinical trial evaluated the effects of external breast expansion on breast density and vessel count using magnetic resonance imaging. Thirty-four enrolled patients were instructed to apply one of two devices, the conventional BRAVA device (used in the AESTES trial) or a novel external expansion device (EVERA) designed for Asian women, continuously for 8 h per day for 12 weeks. For external expansion, the pressure was set to 25 mmHg. Follow-up examinations were performed for 4 weeks after completion of the expansion. The ratio between the fibroglandular and adipose tissues of the breast was measured using T1-weighted MRI, and the number of vessels in the breast tissue was determined before and after the treatment by contrast MRI. Additionally, the volume of the breast was measured by laser scanning before, during, and after the device application. The obtained measurements were compared within and between the groups at different time points. Six patients dropped out, while 28 completed the trial without major side effects or adverse events. External expansion significantly increased breast vessel count in both the EVERA and AESTES groups (p = 0.019, p = 0.022). However, it did not significantly change breast density in either group (p = 0.186, p = 0.638). No significant intergroup differences were noted in vessel count (p = 0.874) or density (p = 0.482). Breast volume increases after 12 weeks of application were statistically significant in both groups, with mean changes of 81 ± 22 cc (AESTES) and 98 ± 30 cc (EVERA) (p < 0.001 in both cases). External expansion resulted in a marked increase in breast vessel count but did not affect breast density. The observed increase in breast volume can be considered substantial for Asian women. Level II, therapeutic study. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

    NASA Technical Reports Server (NTRS)

    Chan, Eugene

    2015-01-01

    The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

  5. A microchip CD4 counting method for HIV monitoring in resource-poor settings.

    PubMed

    Rodriguez, William R; Christodoulides, Nicolaos; Floriano, Pierre N; Graham, Susan; Mohanty, Sanghamitra; Dixon, Meredith; Hsiang, Mina; Peter, Trevor; Zavahir, Shabnam; Thior, Ibou; Romanovicz, Dwight; Bernard, Bruce; Goodey, Adrian P; Walker, Bruce D; McDevitt, John T

    2005-07-01

    More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.

  6. 34 CFR 200.91 - SEA counts of eligible children.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false SEA counts of eligible children. 200.91 Section 200.91... Dropping Out § 200.91 SEA counts of eligible children. To receive an allocation under part D, subpart 1 of Title I of the ESEA, an SEA must provide the Secretary with a count of children and youth under the age...

  7. 34 CFR 200.91 - SEA counts of eligible children.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false SEA counts of eligible children. 200.91 Section 200.91... Dropping Out § 200.91 SEA counts of eligible children. To receive an allocation under part D, subpart 1 of Title I of the ESEA, an SEA must provide the Secretary with a count of children and youth under the age...

  8. 34 CFR 200.91 - SEA counts of eligible children.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false SEA counts of eligible children. 200.91 Section 200.91... Dropping Out § 200.91 SEA counts of eligible children. To receive an allocation under part D, subpart 1 of Title I of the ESEA, an SEA must provide the Secretary with a count of children and youth under the age...

  9. 34 CFR 200.91 - SEA counts of eligible children.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false SEA counts of eligible children. 200.91 Section 200.91... Dropping Out § 200.91 SEA counts of eligible children. To receive an allocation under part D, subpart 1 of Title I of the ESEA, an SEA must provide the Secretary with a count of children and youth under the age...

  10. 34 CFR 200.91 - SEA counts of eligible children.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 1 2012-07-01 2012-07-01 false SEA counts of eligible children. 200.91 Section 200.91... Dropping Out § 200.91 SEA counts of eligible children. To receive an allocation under part D, subpart 1 of Title I of the ESEA, an SEA must provide the Secretary with a count of children and youth under the age...

  11. Counting Raindrops and the Distribution of Intervals Between Them.

    NASA Astrophysics Data System (ADS)

    Van De Giesen, N.; Ten Veldhuis, M. C.; Hut, R.; Pape, J. J.

    2017-12-01

    Drop size distributions are often assumed to follow a generalized gamma function, characterized by one parameter, Λ, [1]. In principle, this Λ can be estimated by measuring the arrival rate of raindrops. The arrival rate should follow a Poisson distribution. By measuring the distribution of the time intervals between drops arriving at a certain surface area, one should not only be able to estimate the arrival rate but also the robustness of the underlying assumption concerning steady state. It is important to note that many rainfall radar systems also assume fixeddrop size distributions, and associated arrival rates, to derive rainfall rates. By testing these relationships with a simple device, we will be able to improve both land-based and space-based radar rainfall estimates. Here, an open-hardware sensor design is presented, consisting of a 3D printed housing for a piezoelectric element, some simple electronics and an Arduino. The target audience for this device are citizen scientists who want to contribute to collecting rainfall information beyond the standard rain gauge. The core of the sensor is a simple piezo-buzzer, as found in many devices such as watches and fire alarms. When a raindrop falls on a piezo-buzzer, a small voltage is generated , which can be used to register the drop's arrival time. By registering the intervals between raindrops, the associated Poisson distribution can be estimated. In addition to the hardware, we will present the first results of a measuring campaign in Myanmar that will have ran from August to October 2017. All design files and descriptions are available through GitHub: https://github.com/nvandegiesen/Intervalometer. This research is partially supported through the TWIGA project, funded by the European Commission's H2020 program under call SC5-18-2017 `Novel in-situ observation systems'. Reference [1]: Uijlenhoet, R., and J. N. M. Stricker. "A consistent rainfall parameterization based on the exponential raindrop size distribution." Journal of Hydrology 218, no. 3 (1999): 101-127.

  12. 25 CFR 39.210 - When must a school drop a student from its membership?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SCHOOL EQUALIZATION PROGRAM Administrative Procedures, Student Counts, and Verifications § 39.210 When must a school drop a student from its membership? If a student is absent for 10 consecutive school days... 25 Indians 1 2010-04-01 2010-04-01 false When must a school drop a student from its membership? 39...

  13. Comparison of Raindrop Size Distribution Measurements by Collocated Disdrometers

    NASA Technical Reports Server (NTRS)

    Tokay, Ali; Petersen, Walter A.; Gatlin, Patrick; Wingo, Matthew

    2013-01-01

    An impact-type Joss-Waldvogel disdrometer (JWD), a two-dimensional video disdrometer (2DVD), and a laser optical OTT Particle Size and Velocity (PARSIVEL) disdrometer (PD) were used to measure the raindrop size distribution (DSD) over a 6-month period in Huntsville, Alabama. Comparisons indicate event rain totals for all three disdrometers that were in reasonable agreement with a reference rain gauge. In a relative sense, hourly composite DSDs revealed that the JWD was more sensitive to small drops (,1 mm), while the PD appeared to severely underestimate small drops less than 0.76mm in diameter. The JWD and 2DVD measured comparable number concentrations of midsize drops (1-3mm) and large drops (3-5 mm), while the PD tended to measure relatively higher drop concentrations at sizes larger than 2.44mm in diameter. This concentration disparity tended to occur when hourly rain rates and drop counts exceeded 2.5mm/h and 400/min, respectively. Based on interactions with the PD manufacturer, the partially inhomogeneous laser beam is considered the cause of the PD drop count overestimation. PD drop fall speeds followed the expected terminal fall speed relationship quite well, while the 2DVD occasionally measured slower drops for diameters larger than 2.4mm, coinciding with events where wind speeds were greater than 4m/s. The underestimation of small drops by the PD had a pronounced effect on the intercept and shape of parameters of gamma-fitted DSDs, while the overestimation of midsize and larger drops resulted in higher mean values for PD integral rain parameters

  14. Experimental Measurements at the MASURCA Facility

    NASA Astrophysics Data System (ADS)

    Assal, W.; Bosq, J. C.; Mellier, F.

    2012-12-01

    Dedicated to the neutronics studies of fast and semi-fast reactor lattices, MASURCA (meaning “mock-up facility for fast breeder reactor studies at CADARACHE”) is an airflow cooled fast reactor operating at a maximum power of 5 kW playing an important role in the CEA research activities. At this facility, a lot of neutron integral experimental programs were undertaken. The purpose of this poster is to show a panorama of the facility from this experimental measurement point of view. A hint at the forthcoming refurbishment will be included. These programs include various experimental measurements (reactivity, distributions of fluxes, reaction rates), performed essentially with fission chambers, in accordance with different methods (noise methods, radial or axial traverses, rod drops) and involving several devices systems (monitors, fission chambers, amplifiers, power supplies, data acquisition systems ...). For this purpose are implemented electronics modules to shape the signals sent from the detectors in various mode (fluctuation, pulse, current). All the electric and electronic devices needed for these measurements and the relating wiring will be fully explained through comprehensive layouts. Data acquired during counting performed at the time of startup phase or rod drops are analyzed by the mean of a Neutronic Measurement Treatment (TMN in French) programmed on the basis of the MATLAB software. This toolbox gives the opportunity of data files management, reactivity valuation from neutronics measurements and transient or divergence simulation at zero power. Particular TMN using at MASURCA will be presented.

  15. Low latency counter event indication

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2008-09-16

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  16. Low latency counter event indication

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-08-24

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  17. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  18. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-03-30

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  19. Quality control of Kato slide counts for Schistosoma mansoni: a review of 12 years' experience in Kenya.

    PubMed Central

    Sturrock, R. F.; Ouma, J. H.; Kariuki, H. C.; Thiongo, F. W.; Koech, D. K.; Butterworth, A. E.

    1997-01-01

    A total of 19 annual or biannual audits were performed over a 12-year period by an independent microscopist on randomized subsamples of Kato slides examined for Schistosoma mansoni eggs by Kenyan microscopists from the Division of Vector-borne Diseases (DVBD). The recounts were invariably lower than the originals owing to some deterioration of the preparations between counts, but the two were strongly correlated: significant regressions of recounts on counts taking up 80-90% of the observed variance. Observer bias differed significantly between microscopists but remained stable over time, whereas repeatability of recounts on counts dropped slightly in periods of maximum work load but did not vary systematically with time. Approximately 7% of the counts and recounts disagreed on the presence or absence of eggs, but less than a third of these were negatives that were found positive on recount. False negatives dropped to 1.3% if duplicate counts were considered. The performance of the Kenyan microscopists was remarkably high and consistent throughout the 12-year period. This form of quality control is suitable for projects where limited funds preclude full-time supervisors using more sophisticated systems. PMID:9447781

  20. Football APP based on smart phone with FES in drop foot rehabilitation.

    PubMed

    Ciou, Shih-Hsiang; Hwang, Yuh-Shyan; Chen, Chih-Chen; Luh, Jer-Junn; Chen, Shih-Ching; Chen, Yu-Luen

    2017-01-01

    Long-term, sustained progress is necessary in drop foot rehabilitation. The necessary inconvenient body training movements, the return trips to the hospital and repetitive boring training using functional electrical stimulation (FES) often results in the patient suspending their training. The patient's drop foot rehabilitation will not progress if training is suspended. A fast spread, highly portable drop foot rehabilitation training device based on the smart phone is presented. This device is combined with a self-made football APP and feedback controlled FES. The drop foot patient can easily engage in long term rehabilitation training that is more convenient and interesting. An interactive game is established on the smart phone with the Android system using the originally built-in wireless communications. The ankle angle information is detected by an external portable device as the game input signal. The electrical stimulation command to the external device is supplemented with FES stimulation for inadequate ankle efforts. After six-weeks training using six cases, the results indicated that this training device showed significant performance improvement (p< 0.05) in the patient's ankle dorsiflexion strength, ankle dorsiflexion angle, control timing and Timed Up and Go. Preliminary results show that this training device provides significant positive help to drop foot patients. Moreover, this device is based on existing and universally popular mobile processing, which can be rapidly promoted. The responses of clinical cases also show this system is easy to operate, convenient and entertaining. All of these features can improve the patient's willingness to engage in long term rehabilitation.

  1. Field performance of a low-cost and fully-automated blood counting system operated by trained and untrained users (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Xie, Dengling; Xie, Yanjun; Liu, Peng; Tong, Lieshu; Chu, Kaiqin; Smith, Zachary J.

    2017-02-01

    Current flow-based blood counting devices require expensive and centralized medical infrastructure and are not appropriate for field use. In this paper we report a method to count red blood cells, white blood cells as well as platelets through a low-cost and fully-automated blood counting system. The approach consists of using a compact, custom-built microscope with large field-of-view to record bright-field and fluorescence images of samples that are diluted with a single, stable reagent mixture and counted using automatic algorithms. Sample collection is performed manually using a spring loaded lancet, and volume-metering capillary tubes. The capillaries are then dropped into a tube of pre-measured reagents and gently shaken for 10-30 seconds. The sample is loaded into a measurement chamber and placed on a custom 3D printed platform. Sample translation and focusing is fully automated, and a user has only to press a button for the measurement and analysis to commence. Cost of the system is minimized through the use of custom-designed motorized components. We performed a series of comparative experiments by trained and untrained users on blood from adults and children. We compare the performance of our system, as operated by trained and untrained users, to the clinical gold standard using a Bland-Altman analysis, demonstrating good agreement of our system to the clinical standard. The system's low cost, complete automation, and good field performance indicate that it can be successfully translated for use in low-resource settings where central hematology laboratories are not accessible.

  2. Defecation rate in captive European bison, Bison bonasus.

    PubMed

    Eycott, Amy; Daleszczyk, Katarzyna; Drese, Jacqueline; Cantero, Adrià Solé; Pèbre, Jennifer; Gladys, Samuel

    2013-01-01

    Data on the digestive characteristics of European bison, Bison bonasus (L.), are needed for studies of their role as the largest extant herbivore in Europe and a potential keystone species of the temperate forest ecosystem. Very little published data are available, particularly on the defecation rate which affects population estimates from dropping counts and also the individual seed deposition rate. We gathered data from a captive bison group kept at the Show Reserve of the Białowieża National Park. Droppings accumulated in the enclosure over a 72-h period were counted in winter 2010. In addition, the group was observed over approximately 6-h periods three times in winter and 16 times in summer. The count of accumulated droppings over a 72-h period gave eight defecations per day. The summer direct observations recorded 7.5 defecations per day and winter observation 5.4 defecations per day. These estimates are within the range for other bovids of similar size. The difference between summer and winter observation-based estimates may be accounted for by a higher frequency of defecation in early morning and late afternoon, periods not covered in winter observations. Given the published density of seedlings emerging from droppings of the ∼470 free-living bison in the nearby forest, eight defecations a day mean that seed deposition by European bison may contribute significantly to realize seed dispersal and plant establishment.

  3. Microwave Dielectric Heating of Drops in Microfluidic Devices†

    PubMed Central

    Issadore, David; Humphry, Katherine J.; Brown, Keith A.; Sandberg, Lori; Weitz, David; Westervelt, Robert M.

    2010-01-01

    We present a technique to locally and rapidly heat water drops in microfluidic devices with microwave dielectric heating. Water absorbs microwave power more efficiently than polymers, glass, and oils due to its permanent molecular dipole moment that has a large dielectric loss at GHz frequencies. The relevant heat capacity of the system is a single thermally isolated picoliter drop of water and this enables very fast thermal cycling. We demonstrate microwave dielectric heating in a microfluidic device that integrates a flow-focusing drop maker, drop splitters, and metal electrodes to locally deliver microwave power from an inexpensive, commercially available 3.0 GHz source and amplifier. The temperature of the drops is measured by observing the temperature dependent fluorescence intensity of cadmium selenide nanocrystals suspended in the water drops. We demonstrate characteristic heating times as short as 15 ms to steady-state temperatures as large as 30°C above the base temperature of the microfluidic device. Many common biological and chemical applications require rapid and local control of temperature, such as PCR amplification of DNA, and can benefit from this new technique. PMID:19495453

  4. 33 CFR 159.127 - Safety coliform count: Recirculating devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...

  5. Controlling Vapor Pressure In Hanging-Drop Crystallization

    NASA Technical Reports Server (NTRS)

    Carter, Daniel C.; Smith, Robbie

    1988-01-01

    Rate of evaporation adjusted to produce larger crystals. Device helps to control vapor pressure of water and other solvents in vicinity of hanging drop of solution containing dissolved enzyme protein. Well of porous frit (sintered glass) holds solution in proximity to drop of solution containing protein or enzyme. Vapor from solution in frit controls evaporation of solvent from drop to control precipitation of protein or enzyme. With device, rate of nucleation limited to decrease number and increase size (and perhaps quality) of crystals - large crystals of higher quality needed for x-ray diffraction studies of macromolecules.

  6. Rapid surface colony counts determination with three new miniaturised techniques.

    PubMed

    Malik, K A

    1977-01-01

    Three different miniaturised methods for the rapid surface viable counting are described. The methods were tried in parallel to seven different existing methods (Table 1) for viable counts and were found to be easier, quicker and insome cases more accurate. The techniques require about 10% of the material and time needed for conventional spread-plates method and the results were in no way inferior to that (Table 1 and 2). Mini agar discs were cut aseptically with an especially designed stainless steel agar disc cutter (25 mm internal and 28 mm external diameter, Fig. 1b) or with a test tube of similar diameter. The area of the resulted mini-agar-disc of 25 mm diameter was kept such (about 1/10th of the normal plate) that the ratio of the colony-bearing area to the inoculm remained the same as on big plates in spread-plate-method (Table 2). In normal Petri dishes (about 90 mm diameter) up to seven mini agar discs were possible to cut. Each small agar disc was seperated from the other mini-disc by a distance of at least 6 mm (Fig. 1a). The empty place around the disc was still enlarged during over drying of the plates and during incubation. This created complete isolation from the neighbouring disc. For micro-determination of surface viable counts 10 micronl from each dilution was delivered on a well-dired mini-disc with a piston micropipette. The inoculm was immediately spread on the whole mini-disc with a specially designed flame sterilizable platinum-Mini-spreader (Fig. 2a). No spinning of the plate was needed. Alternatively the dropping pipette and spreader was replaced by a calibrated platinum wire Loop-spreader (Fig. 2b). A loop of 3 mm internal diameter made from a platinum-iridium wire of 0.75 mm thickness proved most useful and carried a drop of 10 micronl. Differences especially in surface tension of various diluting fluids did not influence to drop of this size and no recalibration was needed for water and nutrient broth. The loop was further shaped to Loop-spreader form. From each bacterial suspension 10 micronl were carried and spread on each mini-disc. The method is useful for pathogenic organisms as the loop can readily be flame sterilized. For routine purposes where only approximate numbers of bacteria need to be known a still rapid semiquantitative method was deviced making use of a calibrated stainless steel Stamping-disc (Fig. 2c). A disc of 25mm diameter and 1 mm thickness delivered approximateyl 10 microlitres of supensions and was found to be most useful to stamp seven dilutions on a single plate. In collections and bacteriology laboratories where by conventional methods large number of plates are to be plated and counted the presented techniques could prove most convenient, rapid and economical.

  7. A microfluidic biochip for complete blood cell counts at the point-of-care

    PubMed Central

    Hassan, U.; Reddy, B.; Damhorst, G.; Sonoiki, O.; Ghonge, T.; Yang, C.; Bashir, R.

    2016-01-01

    Complete blood cell counts (CBCs) are one of the most commonly ordered and informative blood tests in hospitals. The results from a CBC, which typically include white blood cell (WBC) counts with differentials, red blood cell (RBC) counts, platelet counts and hemoglobin measurements, can have implications for the diagnosis and screening of hundreds of diseases and treatments. Bulky and expensive hematology analyzers are currently used as a gold standard for acquiring CBCs. For nearly all CBCs performed today, the patient must travel to either a hospital with a large laboratory or to a centralized lab testing facility. There is a tremendous need for an automated, portable point-of-care blood cell counter that could yield results in a matter of minutes from a drop of blood without any trained professionals to operate the instrument. We have developed microfluidic biochips capable of a partial CBC using only a drop of whole blood. Total leukocyte and their 3-part differential count are obtained from 10 μL of blood after on-chip lysing of the RBCs and counting of the leukocytes electrically using microfabricated platinum electrodes. For RBCs and platelets, 1 μL of whole blood is diluted with PBS on-chip and the cells are counted electrically. The total time for measurement is under 20 minutes. We demonstrate a high correlation of blood cell counts compared to results acquired with a commercial hematology analyzer. This technology could potentially have tremendous applications in hospitals at the bedside, private clinics, retail clinics and the developing world. PMID:26909365

  8. A microfluidic biochip for complete blood cell counts at the point-of-care.

    PubMed

    Hassan, U; Reddy, B; Damhorst, G; Sonoiki, O; Ghonge, T; Yang, C; Bashir, R

    2015-12-01

    Complete blood cell counts (CBCs) are one of the most commonly ordered and informative blood tests in hospitals. The results from a CBC, which typically include white blood cell (WBC) counts with differentials, red blood cell (RBC) counts, platelet counts and hemoglobin measurements, can have implications for the diagnosis and screening of hundreds of diseases and treatments. Bulky and expensive hematology analyzers are currently used as a gold standard for acquiring CBCs. For nearly all CBCs performed today, the patient must travel to either a hospital with a large laboratory or to a centralized lab testing facility. There is a tremendous need for an automated, portable point-of-care blood cell counter that could yield results in a matter of minutes from a drop of blood without any trained professionals to operate the instrument. We have developed microfluidic biochips capable of a partial CBC using only a drop of whole blood. Total leukocyte and their 3-part differential count are obtained from 10 μL of blood after on-chip lysing of the RBCs and counting of the leukocytes electrically using microfabricated platinum electrodes. For RBCs and platelets, 1 μL of whole blood is diluted with PBS on-chip and the cells are counted electrically. The total time for measurement is under 20 minutes. We demonstrate a high correlation of blood cell counts compared to results acquired with a commercial hematology analyzer. This technology could potentially have tremendous applications in hospitals at the bedside, private clinics, retail clinics and the developing world.

  9. Marking Ground Targets With Radio Transmitters Dropped From Aircraft

    Treesearch

    Thomas H. Nichols; Michael E. Ostry; Mark R. Fuller

    1981-01-01

    Reports development and use of a radio transmitter device that can be dropped from aircraft into target areas in remote habitats. Such a device could be a valuable tool for studying and managing forests and wildlife, for controlling forest fires, and for handling emergencies.

  10. Lightweight, Economical Device Alleviates Drop Foot

    NASA Technical Reports Server (NTRS)

    Deis, B. C.

    1983-01-01

    Corrective apparatus alleviates difficulties in walking for victims of drop foot. Elastic line attached to legband provides flexible support to toe of shoe. Device used with flat (heelless) shoes, sneakers, crepe-soled shoes, canvas shoes, and many other types of shoes not usable with short leg brace.

  11. Paradoxical drop in circulating neutrophil count following granulocyte-colony stimulating factor and stem cell factor administration in rhesus macaques.

    PubMed

    Gordon, Brent C; Revenis, Amy M; Bonifacino, Aylin C; Sander, William E; Metzger, Mark E; Krouse, Allen E; Usherson, Tatiana N; Donahue, Robert E

    2007-06-01

    Granulocyte colony-stimulating factor (G-CSF) is frequently used therapeutically to treat chronic or transient neutropenia and to mobilize hematopoietic stem cells. Shortly following G-CSF administration, we observed a dramatic transient drop in circulating neutrophil number. This article characterizes this effect in a rhesus macaque animal model. Hematologic changes were monitored following subcutaneous (SQ) administration of G-CSF. G-CSF was administered as a single SQ dose at 10 microg/kg or 50 microg/kg. It was also administered (10 microg/kg) in combination with stem cell factor (SCF; 200 microg/kg) over 5 days. Flow cytometry was performed on serial blood samples to detect changes in cell surface adhesion protein expression. Neutrophil count dramatically declined 30 minutes after G-CSF administration. This decline was observed whether 10 microg/kg G-CSF was administered in combination with SCF over 5 days, or given as a single 10 microg/kg dose. At a single 50 microg/kg dose, the decline accelerated to 15 minutes. Neutrophil count returned to baseline after 120 minutes and rapidly increased thereafter. An increase in CD11a and CD49d expression coincided with the drop in neutrophil count. A transient paradoxical decline in neutrophil count was observed following administration of G-CSF either alone or in combination with SCF. This decline accelerated with the administration of a higher dose of G-CSF and was associated with an increase in CD11a and CD49d expression. It remains to be determined whether this decline in circulating neutrophils is associated with an increase in endothelial margination and/or entrance into extravascular compartments.

  12. 25 CFR 542.9 - What are the minimum internal control standards for card games?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...

  13. 25 CFR 542.9 - What are the minimum internal control standards for card games?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...

  14. 25 CFR 542.12 - What are the minimum internal control standards for table games?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... games? 542.12 Section 542.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... table games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the table game drop and the count thereof shall comply...

  15. 25 CFR 542.9 - What are the minimum internal control standards for card games?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...

  16. 25 CFR 542.12 - What are the minimum internal control standards for table games?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... games? 542.12 Section 542.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... table games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the table game drop and the count thereof shall comply...

  17. 25 CFR 542.12 - What are the minimum internal control standards for table games?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... games? 542.12 Section 542.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... table games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the table game drop and the count thereof shall comply...

  18. 25 CFR 542.9 - What are the minimum internal control standards for card games?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...

  19. 25 CFR 542.9 - What are the minimum internal control standards for card games?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... games? 542.9 Section 542.9 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... card games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the card game drop and the count thereof shall comply...

  20. 25 CFR 542.12 - What are the minimum internal control standards for table games?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... games? 542.12 Section 542.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... table games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the table game drop and the count thereof shall comply...

  1. 25 CFR 542.12 - What are the minimum internal control standards for table games?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... games? 542.12 Section 542.12 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN... table games? (a) Computer applications. For any computer applications utilized, alternate documentation... and count. The procedures for the collection of the table game drop and the count thereof shall comply...

  2. Technical Complications during Veno-Venous Extracorporeal Membrane Oxygenation and Their Relevance Predicting a System-Exchange – Retrospective Analysis of 265 Cases

    PubMed Central

    Lubnow, Matthias; Philipp, Alois; Foltan, Maik; Bull Enger, Tone; Lunz, Dirk; Bein, Thomas; Haneya, Assad; Schmid, Christof; Riegger, Günter; Müller, Thomas; Lehle, Karla

    2014-01-01

    Objectives Technical complications are a known hazard in veno-venous extracorporeal membrane oxygenation (vvECMO). Identifying these complications and predictive factors indicating a developing system-exchange was the goal of the study. Methods Retrospective study on prospectively collected data of technical complications including 265 adult patients (Regensburg ECMO Registry, 2009-2013) with acute respiratory failure treated with vvECMO. Alterations in blood flow resistance, gas transfer capability, hemolysis, coagulation and hemostasis parameters were evaluated in conjunction with a system-exchange in all patients with at least one exchange (n = 83). Results Values presented as median (interquartile range). Patient age was 50(36–60) years, the SOFA score 11(8–14.3) and the Murray lung injury Score 3.33(3.3–3.7). Cumulative ECMO support time 3411 days, 9(6–15) days per patient. Mechanical failure of the blood pump (n = 5), MO (n = 2) or cannula (n = 1) accounted for 10% of the exchanges. Acute clot formation within the pump head (visible clots, increase in plasma free hemoglobin (frHb), serum lactate dehydrogenase (LDH), n = 13) and MO (increase in pressure drop across the MO, n = 16) required an urgent system-exchange, of which nearly 50% could be foreseen by measuring the parameters mentioned below. Reasons for an elective system-exchange were worsening of gas transfer capability (n = 10) and device-related coagulation disorders (n = 32), either local fibrinolysis in the MO due to clot formation (increased D-dimers [DD]), decreased platelet count; n = 24), or device-induced hyperfibrinolysis (increased DD, decreased fibrinogen [FG], decreased platelet count, diffuse bleeding tendency; n = 8), which could be reversed after system-exchange. Four MOs were exchanged due to suspicion of infection. Conclusions The majority of ECMO system-exchanges could be predicted by regular inspection of the complete ECMO circuit, evaluation of gas exchange, pressure drop across the MO and laboratory parameters (DD, FG, platelets, LDH, frHb). These parameters should be monitored in the daily routine to reduce the risk of unexpected ECMO failure. PMID:25464516

  3. Characteristics of nuclepore filters with large pore size—I. Physical properties

    NASA Astrophysics Data System (ADS)

    John, W.; Hering, S.; Reischl, G.; Sasaki, G.; Goren, S.

    Measurements of pore diameter, pore density and filter thickness have been made on Nuclepore filters of 5, 8 and 12 μm pore size. The areal distribution of the pores is random, as verified by total hole counts and by counts of overlapping holes. Filter thicknesses decrease with increasing pore diameter. The Hagen-Poiseuille formula accounts for less than half of the measured pressure drop across 12 μm pore size filters. A new calculation, including a term for the pressure drop external to the filter, accounts quantitatively for the observations. There are sufficient variations among filter batches to require knowledge of the filter parameters for each batch to ensure accurate measurements using these filters.

  4. Immediate transient thrombocytopenia at the time of alemtuzumab infusion in multiple sclerosis.

    PubMed

    Ranganathan, Usha; Kaunzner, Ulrike; Foster, Stacyann; Vartanian, Timothy; Perumal, Jai S

    2018-04-01

    Alemtuzumab is a monoclonal antibody approved for relapsing-remitting multiple sclerosis (RRMS). Although Immune thrombocytopenia (ITP) has been reported as a secondary autoimmune phenomenon following alemtuzumab infusion, immediate thrombocytopenia during the infusion has not been reported. We report transient, reversible, self-limiting acute-onset thrombocytopenia during the first course with alemtuzumab. In total, 3 of 22 paitents developed mild self-limited bruising associated with a drop in platelet count from their baseline during the intial 5-day course of alemtuzumab. Upon chart review, all 22 patients who received alemtuzumab developed an immediate mostly asymptomatic drop in platelet count which returned to normal within 2 months post-infusion.

  5. CD4+, CD8+, CD3+ cell counts and CD4+/CD8+ ratio among patients with mycobacterial diseases (leprosy, tuberculosis), HIV infections, and normal healthy adults: a comparative analysis of studies in different regions of India.

    PubMed

    Hussain, Tahziba; Kulshreshtha, K K; Yadav, V S; Katoch, Kiran

    2015-01-01

    In this study, we estimated the CD4+, CD8+, CD3+ cell counts and the CD4/CD8 ratio among normal healthy controls (adults and children), leprosy patients (without any complications and during reactional states), TB patients (with and without HIV), and HIV-positive patients (early infection and full-blown AIDS) and correlated the changes with disease progression. In our study, it was observed that among adults, CD4+ cell counts ranged from 518-1098, CD8+ from 312-952, whereas CD4/CD8 ratio from 0.75-2.30. Among children, both CD4+ and CD8+ cells were more and the CD4/CD8 ratio varied from 0.91-3.17. With regard to leprosy patients, we observed that CD4+ and CD8+ cell counts were lower among PB (pauci-bacillary) and MB (multi-bacillary) patients. CD4/CD8 ratio was 0.99 ± 0.28 among PB patients while the ratio was lower, 0.78 ± 0.20, among MB patients. CD4+ cell counts were raised during RR (reversal reactions) and ENL (erythema nodosum leprosum) among the PB and MB patients whereas the CD8+ cell counts were lower among PB and MB patients. CD4/CD8 ratio doubled during reactional episodes of RR and ENL. Among the HIV-negative tuberculosis (TB) patients, both the CD4+ and CD8+ cell counts were found to be less and the CD4/CD8 ratio varied between 0.53-1.75. Among the HIV-positive TB patients and HIV-positive patients, both the CD4+ and CD8+ cells were very less and ratio drops significantly. In the initial stages of infection, as CD4+ counts drop, an increase in the CD8+ cell counts was observed and the ratio declines. In full-blown cases, CD4+ cell counts were very low, 3-4 to 54 cells, CD8+ cells from 12-211 and the ratio drops too low. This study is the first of its kind in this region of the country and assumes importance since no other study has reported the values of CD4+ and CD8+ T-lymphocyte counts among patients with mycobacterial diseases (leprosy and TB), HIV infections along with normal healthy individuals of the region, and correlation with clinical presentations of patients.

  6. Athermal Photonic Devices and Circuits on a Silicon Platform

    NASA Astrophysics Data System (ADS)

    Raghunathan, Vivek

    In recent years, silicon based optical interconnects has been pursued as an effective solution that can offer cost, energy, distance and bandwidth density improvements over copper. Monolithic integration of optics and electronics has been enabled by silicon photonic devices that can be fabricated using CMOS technology. However, high levels of device integration result in significant local and global temperature fluctuations that prove problematic for silicon based photonic devices. In particular, high temperature dependence of Si refractive index (thermo-optic (TO) coefficient) shifts the filter response of resonant devices that limit wavelength resolution in various applications. Active thermal compensation using heaters and thermo-electric coolers are the legacy solution for low density integration. However, the required electrical power, device foot print and number of input/output (I/O) lines limit the integration density. We present a passive approach to an athermal design that involves compensation of positive TO effects from a silicon core by negative TO effects of the polymer cladding. In addition, the design rule involves engineering the waveguide core geometry depending on the resonance wavelength under consideration to ensure desired amount of light in the polymer. We develop exact design requirements for a TO peak stability of 0 pm/K and present prototype performance of 0.5 pm/K. We explore the material design space through initiated chemical vapor deposition (iCVD) of 2 polymer cladding choices. We study the effect of cross-linking on the optical properties of a polymer and establish the superior performance of the co-polymer cladding compared to the homo-polymer. Integration of polymer clad devices in an electronic-photonic architecture requires the possibility of multi-layer stacking capability. We use a low temperature, high density plasma chemical vapor deposition of SiO2/SiN x to hermetically seal the athermal. Further, we employ visible light for post-fabrication trimming of athermal rings by sandwiching a thin photosensitive layer of As2S3 in between amorphous Si core and polymer top cladding. System design of an add-drop filter requires an optimum combination of channel counts performance and power handling capacity for maximum aggregate bandwidth. We establish the superior performance of athermal add-drop filter compared to a standard filter treating bandwidth as the figure-of-merit. (Copies available exclusively from MIT Libraries, libraries.mit.edu/docs - docs mit.edu)

  7. Casimir meets Poisson: improved quark/gluon discrimination with counting observables

    DOE PAGES

    Frye, Christopher; Larkoski, Andrew J.; Thaler, Jesse; ...

    2017-09-19

    Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that trackmore » multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.« less

  8. Casimir meets Poisson: improved quark/gluon discrimination with counting observables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frye, Christopher; Larkoski, Andrew J.; Thaler, Jesse

    Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that trackmore » multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.« less

  9. Self-Powered Viscosity and Pressure Sensing in Microfluidic Systems Based on the Piezoelectric Energy Harvesting of Flowing Droplets.

    PubMed

    Wang, Zhao; Tan, Lun; Pan, Xumin; Liu, Gao; He, Yahua; Jin, Wenchao; Li, Meng; Hu, Yongming; Gu, Haoshuang

    2017-08-30

    The rapid development of microscaled piezoelectric energy harvesters has provided a simple and highly efficient way for building self-powered sensor systems through harvesting the mechanical energy from the ambient environment. In this work, a self-powered microfluidic sensor that can harvest the mechanical energy of the fluid and simultaneously monitor their characteristics was fabricated by integrating the flexible piezoelectric poly(vinylidene fluoride) (PVDF) nanofibers with the well-designed microfluidic chips. Those devices could generate open-circuit high output voltage up to 1.8 V when a droplet of water is flowing past the suspended PVDF nanofibers and result in their periodical deformations. The impulsive output voltage signal allowed them to be utilized for droplets or bubbles counting in the microfluidic systems. Furthermore, the devices also exhibited self-powered sensing behavior due to the decreased voltage amplitude with increasing input pressure and liquid viscosity. The drop of output voltage could be attributed to the variation of flow condition and velocity of the droplets, leading to the reduced deformation of the piezoelectric PVDF layer and the decrease of the generated piezoelectric potential.

  10. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  11. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  12. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  13. Effects of probiotic fermented milk on biofilms, oral microbiota, and enamel.

    PubMed

    Lodi, Carolina Simonetti; Oliveira, Lidiane Viana; Brighenti, Fernanda Lourenção; Delbem, Alberto Carlos Botazzo; Martinhon, Cleide Cristina Rodrigues

    2015-01-01

    The aim of this study was to evaluate in vitro and in vivo the effects of 2 brands of probiotic fermented milk on biofilms, oral microbiota, and enamel. For the in situ experiment, ten volunteers wore palatine devices containing four blocks of bovine dental enamel over 3 phases, during which 20% sucrose solution, Yakult® (Treatment A), and Batavito® (Treatment B) were dropped on the enamel blocks. Salivary microbial counts were obtained and biofilm samples were analyzed after each phase. For the in vivo experiment, the same ten volunteers drunk Yakult® (Treatment C) and Batavito® (Treatment D) in two phases. Saliva samples were collected for microbial analysis after each phase. The in situ study showed that in comparison with Treatment A, Treatment B resulted in fewer total cultivable anaerobes and facultative microorganisms in biofilms, higher final microhardness, lower percentage change in surface hardness, and smaller integrated subsurface enamel hardness. In the in vivo study, Treatment D resulted in a reduction in the counts of all microorganisms. The results suggested that the probiotic fermented milk Batavito®, but not Yakult®, reduced the amount of oral microorganisms and mineral loss in bovine enamel.

  14. 49 CFR 173.175 - Permeation devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., flat and horizontal surface from a height of 1.8 m (5.9 feet): (i) One drop flat on the bottom; (ii) One drop flat on the top; (iii) One drop flat on the long side; (iv) One drop flat on the short side; (v) One drop on a corner at the junction of three intersecting edges; and (2) A force applied to the...

  15. 49 CFR 173.175 - Permeation devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., flat and horizontal surface from a height of 1.8 m (5.9 feet): (i) One drop flat on the bottom; (ii) One drop flat on the top; (iii) One drop flat on the long side; (iv) One drop flat on the short side; (v) One drop on a corner at the junction of three intersecting edges; and (2) A force applied to the...

  16. Innovative architecture of switching device for expanding the applications in fiber to the home (FTTH)

    NASA Astrophysics Data System (ADS)

    Mahmoud, Mohamed; Fayed, Heba A.; Aly, Moustafa H.; Aboul Seoud, A. K.

    2011-08-01

    A new device, optical cross add drop multiplexer (OXADM), is proposed and analyzed. It uses the combination concept of optical add drop multiplexer (OADM) and optical cross connect (OXC). It enables a wavelength switch while implementing add and drop functions simultaneously. So, it expands the applications in fiber to the home (FTTH) and optical core networks. A very high isolation crosstalk level (~ 60 dB) is achieved. Also, a bidirectional OXADM and N×N OXADM are proposed. Finally, a multistage OXADM is presented making some sort of wavelength buffering. To make these devices operate more efficient, tunable fiber Bragg gratings (TFBGs) switches are used to control the operation mechanism.

  17. Ultra high voltage MOS controlled 4H-SiC power switching devices

    NASA Astrophysics Data System (ADS)

    Ryu, S.; Capell, C.; Van Brunt, E.; Jonas, C.; O'Loughlin, M.; Clayton, J.; Lam, K.; Pala, V.; Hull, B.; Lemma, Y.; Lichtenwalner, D.; Zhang, Q. J.; Richmond, J.; Butler, P.; Grider, D.; Casady, J.; Allen, S.; Palmour, J.; Hinojosa, M.; Tipton, C. W.; Scozzie, C.

    2015-08-01

    Ultra high voltage (UHV, >15 kV) 4H-silicon carbide (SiC) power devices have the potential to significantly improve the system performance, reliability, and cost of energy conversion systems by providing reduced part count, simplified circuit topology, and reduced switching losses. In this paper, we compare the two MOS based UHV 4H-SiC power switching devices; 15 kV 4H-SiC MOSFETs and 15 kV 4H-SiC n-IGBTs. The 15 kV 4H-SiC MOSFET shows a specific on-resistance of 204 mΩ cm2 at 25 °C, which increased to 570 mΩ cm2 at 150 °C. The 15 kV 4H-SiC MOSFET provides low, temperature-independent, switching losses which makes the device more attractive for applications that require higher switching frequencies. The 15 kV 4H-SiC n-IGBT shows a significantly lower forward voltage drop (VF), along with reasonable switching performance, which make it a very attractive device for high voltage applications with lower switching frequency requirements. An electrothermal analysis showed that the 15 kV 4H-SiC n-IGBT outperforms the 15 kV 4H-SiC MOSFET for applications with switching frequencies of less than 5 kHz. It was also shown that the use of a carrier storage layer (CSL) can significantly improve the conduction performance of the 15 kV 4H-SiC n-IGBTs.

  18. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Tai, Yu-Chong (Inventor); Kasdan, Harvey L. (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor)

    2016-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  19. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey (Inventor); Tai, Yu-Chong (Inventor)

    2015-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  20. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  1. Investigation in Simulated Vertical Descent of the Characteristics of a Cargo-Dropping Device having Extensible Rotating Blades

    NASA Technical Reports Server (NTRS)

    Stone, Ralph W., Jr.; Hultz, Burton E.

    1949-01-01

    The characteristics of a cargo-dropping device having extensible rotating blades as load-carrying surfaces have been studied in simulated vertical descent in the Langley 20-foot free-spinning tunnel. The investigation included tests to determine the variation in vertical sinking speed with load. A study of the blade characteristics and of the test results indicated a method of dynamically balancing the blades to permit proper functioning of the device.

  2. 33 CFR 159.127 - Safety coliform count: Recirculating devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety coliform count: Recirculating devices. 159.127 Section 159.127 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159...

  3. Puffing Topography and Nicotine Intake of Electronic Cigarette Users

    PubMed Central

    Behar, Rachel Z.; Hua, My; Talbot, Prue

    2015-01-01

    Background Prior electronic cigarette (EC) topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake. Objectives This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake. Methods Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10–15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data. Results Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff), volume/puff (51ml/puff), total puff volume (1,579 ml), EC fluid consumption (79.6 mg), flow rate (20 ml/s), and peak flow rate (27 ml/s) were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers. Conclusions EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products. PMID:25664463

  4. Error Characterization and Mitigation for 16Nm MLC NAND Flash Memory Under Total Ionizing Dose Effect

    NASA Technical Reports Server (NTRS)

    Li, Yue (Inventor); Bruck, Jehoshua (Inventor)

    2018-01-01

    A data device includes a memory having a plurality of memory cells configured to store data values in accordance with a predetermined rank modulation scheme that is optional and a memory controller that receives a current error count from an error decoder of the data device for one or more data operations of the flash memory device and selects an operating mode for data scrubbing in accordance with the received error count and a program cycles count.

  5. Process analytical technology to understand the disintegration behavior of alendronate sodium tablets.

    PubMed

    Xu, Xiaoming; Gupta, Abhay; Sayeed, Vilayat A; Khan, Mansoor A

    2013-05-01

    Various adverse events including esophagus irritations have been reported with the use of alendronate tablets, likely attributed to the rapid tablet disintegration in the mouth or esophagus. Accordingly, the disintegration of six alendronate tablet drug products was studied using a newly developed testing device equipped with in-line sensors, in addition to the official compendial procedure for measuring the disintegration time. The in-line sensors were used to monitor the particle count and solution pH change to assess the onset and duration of disintegration. A relatively large variation was observed in the disintegration time of the tested drug products using the compendial method. The data collected using the in-line sensors suggested that all tested drug products exhibited almost instantaneous onset of disintegration, under 2 s, and a sharp drop in solution pH. The drop in pH was slower for tablets with slower disintegration. The in-house prepared alendronate test tablets also showed similar trends suggesting rapid solubilization of the drug contributed to the fast tablet disintegration. This research highlights the usefulness of the newly developed in-line analytical method in combination with the compendial method in providing a better understanding of the disintegration and the accompanying drug solubilization processes for fast disintegrating tablet drug products. Copyright © 2013 Wiley Periodicals, Inc.

  6. Point-of-care, portable microfluidic blood analyzer system

    NASA Astrophysics Data System (ADS)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  7. 49 CFR 173.175 - Permeation devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., flat and horizontal surface from a height of 1.8 m (5.9 feet): (i) One drop flat on the bottom; (ii) One drop flat on the top; (iii) One drop flat on the long side; (iv) One drop flat on the short side... stacked to a height of 3 m (10 feet) (including the test sample). (3) Each of the above tests may be...

  8. [Trial of eye drops recognizer for visually disabled persons].

    PubMed

    Okamoto, Norio; Suzuki, Katsuhiko; Mimura, Osamu

    2009-01-01

    The development of a device to enable the visually disabled to differentiate eye drops and their dose. The new instrument is composed of a voice generator and a two-dimensional bar-code reader (LS9208). We designed voice outputs for the visually disabled to state when (number of times) and where (right, left, or both) to administer eye drops. We then determined the minimum bar-code size that can be recognized. After attaching bar-codes of the appropriate size to the lateral or bottom surface of the eye drops container, the readability of the bar-codes was compared. The minimum discrimination bar-code size was 6 mm high x 8.5 mm long. Bar-codes on the bottom surface could be more easily recognized than bar-codes on the side. Our newly-developed device using bar-codes enables visually disabled persons to differentiate eye drops and their doses.

  9. Novel all-optical logic gate using an add/drop filter and intensity switch.

    PubMed

    Threepak, T; Mitatha, S; Yupapin, P P

    2011-12-01

    A novel design of all-optical logic device is proposed. An all-optical logic device system composes of an optical intensity switch and add/drop filter. The intensity switch is formed to switch signal by using the relationship between refraction angle and signal intensity. In operation, two input signals are coupled into one with some coupling loss and attenuation, in which the combination of add/drop with intensity switch produces the optical logic gate. The advantage is that the proposed device can operate the high speed logic function. Moreover, it uses low power consumption. Furthermore, by using the extremely small component, this design can be put into a single chip. Finally, we have successfully produced the all-optical logic gate that can generate the accurate AND and NOT operation results.

  10. A side-by-side comparison of Rotorod and Burkard pollen and spore collections.

    PubMed

    Crisp, Howard C; Gomez, Robert A; White, Kevin M; Quinn, James M

    2013-08-01

    The Rotorod sampler and Burkard spore trap are 2 devices commonly used to quantify airborne particles. To evaluate the differences in collections between the 2 devices for a wide range of plant pollens and fungal spores. Pollens and spores were collected simultaneously with each device on 167 days during a 1-year period. The Burkard yielded significantly higher total and individual mold spore counts. It yielded statistically higher total grass, total weed, and Urticaceae daily pollen counts, although the absolute differences were small. Daily counts were positively correlated between the 2 devices for the most abundant pollens and mold spores. The Burkard spore trap collects many more mold spores than the Rotorod over a wide variety of species. The Burkard also yielded higher total grass, total weed, and Urticaceae daily pollen counts. Despite these differences, however, either device can be used to follow trends in the most abundant pollen and mold spores. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  11. Evaporation Flux Distribution of Drops on a Hydrophilic or Hydrophobic Flat Surface by Molecular Simulations.

    PubMed

    Xie, Chiyu; Liu, Guangzhi; Wang, Moran

    2016-08-16

    The evaporation flux distribution of sessile drops is investigated by molecular dynamic simulations. Three evaporating modes are classified, including the diffusion dominant mode, the substrate heating mode, and the environment heating mode. Both hydrophilic and hydrophobic drop-substrate interactions are considered. To count the evaporation flux distribution, which is position dependent, we proposed an azimuthal-angle-based division method under the assumption of spherical crown shape of drops. The modeling results show that the edge evaporation, i.e., near the contact line, is enhanced for hydrophilic drops in all the three modes. The surface diffusion of liquid molecular absorbed on solid substrate for hydrophilic cases plays an important role as well as the space diffusion on the enhanced evaporation rate at the edge. For hydrophobic drops, the edge evaporation flux is higher for the substrate heating mode, but lower than elsewhere of the drop for the diffusion dominant mode; however, a nearly uniform distribution is found for the environment heating mode. The evidence shows that the temperature distribution inside drops plays a key role in the position-dependent evaporation flux.

  12. Design of a Helmet Liner for Improved Low Velocity Impact Protection

    DTIC Science & Technology

    2013-05-01

    FIGURE 14. MONORAIL DROP TEST WITH DOT-SIZE C HEADFORM AND HEMISPHERICAL ANVIL ........................... 14  FIGURE 15. ACH PAD CONFIGURATION. LEFT...materials. In this project, the monorail drop test device, used for the helmeted headform drop test, was modified for material testing as shown in Figure...a guided free fall drop test using a monorail drop test apparatus as shown in Figure 14. All helmets tested in this study were ACH-Size Large and

  13. Microprocessor controlled compliance monitor for eye drop medication.

    PubMed

    Hermann, M M; Diestelhorst, M

    2006-07-01

    The effectiveness of a self administered eye drop medication can only be assessed if the compliance is known. The authors studied the specificity and sensitivity of a new microprocessor controlled monitoring device. The monitoring system was conducted by an 8 bit microcontroller for data acquisition and storage with sensors measuring applied pressure to the bottle, temperature, and vertical position. 10 devices were mounted under commercial 10 ml eye drops. Test subjects had to note down each application manually. A total of 15 applications each within 3 days was intended. Manual reports confirmed 15 applications for each of the 10 bottles. The monitoring devices detected a total of 149 events; one was missed; comprising a sensitivity of 99%. Two devices registered three applications, which did not appear in the manual protocols, indicating a specificity of about 98%. Refrigerated bottles were correctly identified. The battery lifetime exceeded 60 days. The new monitoring device demonstrated a high reliability of the collected compliance data. The important, yet often unknown, influence of compliance in patient care and clinical trials shall be illuminated by the new device. This may lead to a better adapted patient care. Studies will profit from a higher credibility and results will be less influenced by non-compliance.

  14. Self-propulsion of Leidenfrost Drops between Non-Parallel Structures.

    PubMed

    Luo, Cheng; Mrinal, Manjarik; Wang, Xiang

    2017-09-20

    In this work, we explored self-propulsion of a Leidenfrost drop between non-parallel structures. A theoretical model was first developed to determine conditions for liquid drops to start moving away from the corner of two non-parallel plates. These conditions were then simplified for the case of a Leidenfrost drop. Furthermore, ejection speeds and travel distances of Leidenfrost drops were derived using a scaling law. Subsequently, the theoretical models were validated by experiments. Finally, three new devices have been developed to manipulate Leidenfrost drops in different ways.

  15. Hybrid optical fiber add-drop filter based on wavelength dependent light coupling between micro/nano fiber ring and side-polished fiber

    NASA Astrophysics Data System (ADS)

    Yu, Jianhui; Jin, Shaoshen; Wei, Qingsong; Zang, Zhigang; Lu, Huihui; He, Xiaoli; Luo, Yunhan; Tang, Jieyuan; Zhang, Jun; Chen, Zhe

    2015-01-01

    In this paper, we report our experimental study on directly coupling a micro/nano fiber (MNOF) ring with a side-polished fiber(SPF). As a result of the study, the behavior of an add-drop filter was observed. The demonstrated add-drop filter explored the wavelength dependence of light coupling between a MNOF ring and a SPF. The characteristics of the filter and its performance dependence on the MNOF ring diameter were investigated experimentally. The investigation resulted in an empirically obtained ring diameter that showed relatively good filter performance. Since light coupling between a (MNOF) and a conventional single mode fiber has remained a challenge in the photonic integration community, the present study may provide an alternative way to couple light between a MNOF device and a conventional single mode fiber based device or system. The hybridization approach that uses a SPF as a platform to integrate a MNOF device may enable the realization of other all-fiber optical hybrid devices.

  16. Hybrid optical fiber add-drop filter based on wavelength dependent light coupling between micro/nano fiber ring and side-polished fiber.

    PubMed

    Yu, Jianhui; Jin, Shaoshen; Wei, Qingsong; Zang, Zhigang; Lu, Huihui; He, Xiaoli; Luo, Yunhan; Tang, Jieyuan; Zhang, Jun; Chen, Zhe

    2015-01-12

    In this paper, we report our experimental study on directly coupling a micro/nano fiber (MNOF) ring with a side-polished fiber(SPF). As a result of the study, the behavior of an add-drop filter was observed. The demonstrated add-drop filter explored the wavelength dependence of light coupling between a MNOF ring and a SPF. The characteristics of the filter and its performance dependence on the MNOF ring diameter were investigated experimentally. The investigation resulted in an empirically obtained ring diameter that showed relatively good filter performance. Since light coupling between a (MNOF) and a conventional single mode fiber has remained a challenge in the photonic integration community, the present study may provide an alternative way to couple light between a MNOF device and a conventional single mode fiber based device or system. The hybridization approach that uses a SPF as a platform to integrate a MNOF device may enable the realization of other all-fiber optical hybrid devices.

  17. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  18. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  19. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  20. Development of the conceptual framework for the Eye-Drop Satisfaction Questionnaire (EDSQ) in glaucoma using a qualitative study.

    PubMed

    Nordmann, Jean-Philippe; Denis, Philippe; Vigneux, Marc; Trudeau, Elyse; Guillemin, Isabelle; Berdeaux, Gilles

    2007-08-06

    Compliance is a major issue in glaucoma care. It is usually poor in glaucomatous patients, and may ultimately result in an acceleration of the disease progression and a risk of blindness. Reasons for this poor compliance are complex and multifactorial, amongst which patient satisfaction can be counted. The objective of this study was to develop a questionnaire to assess patient satisfaction and compliance with eye-drop treatment. A qualitative study was carried out to develop the questionnaire. An interview guide was developed based on a literature review. Structured interviews of fifteen French and English patients with primary open-angle glaucoma or intraocular hypertension were conducted by trained interviewers of the native language of the interviewees. General concepts and subconcepts were identified from the transcripts. The questionnaire was developed using the patient verbatim, and submitted to six patients (French and English) for cognitive debriefing. Following patients' comments, items were modified and restructured, and a pilot questionnaire was designed. Analysis of data from the interviews with patients and clinicians resulted in the elicitation of concepts related to patient satisfaction and compliance with glaucomatous treatment. These were further refined and used to generate a test questionnaire, which consisted of 46 items grouped into 6 domains: patient characteristics, treatment characteristics, patient-clinician relationship, patient experience with the disease and the treatment, interaction between the patient and the treatment, and patient knowledge of the disease and the treatment. The Eye-Drop Satisfaction Questionnaire (EDSQ) conceptual framework and items were developed simultaneously in French and in English. This questionnaire could be used to evaluate patient satisfaction and compliance with eye-drop treatment and would facilitate the identification of patients at risk of being non-compliant prior to clinical trials or innovative device tests. A psychometric study is under way to validate the questionnaire.

  1. Capillary Thinning of Particle-laden Drops

    NASA Astrophysics Data System (ADS)

    Wagoner, Brayden; Thete, Sumeet; Jahns, Matt; Doshi, Pankaj; Basaran, Osman

    2015-11-01

    Drop formation is central in many applications such as ink-jet printing, microfluidic devices, and atomization. During drop formation, a thinning filament is created between the about-to-form drop and the fluid hanging from the nozzle. Therefore, the physics of capillary thinning of filaments is key to understanding drop formation and has been thoroughly studied for pure Newtonian fluids. The thinning dynamics is, however, altered completely when the fluid contains particles, the physics of which is not well understood. In this work, we explore the impact of solid particles on filament thinning and drop formation by using a combination of experiments and numerical simulations.

  2. Channel add-drop filter based on dual photonic crystal cavities in push-pull mode.

    PubMed

    Poulton, Christopher V; Zeng, Xiaoge; Wade, Mark T; Popović, Miloš A

    2015-09-15

    We demonstrate an add-drop filter based on a dual photonic crystal nanobeam cavity system that emulates the operation of a traveling wave resonator, and, thus, provides separation of the through and drop port transmission from the input port. The device is on a 3×3  mm chip fabricated in an advanced microelectronics silicon-on-insulator complementary metal-oxide semiconductor (SOI CMOS) process (IBM 45 nm SOI) without any foundry process modifications. The filter shows 1 dB of insertion loss in the drop port with a 3 dB bandwidth of 64 GHz, and 16 dB extinction in the through port. To the best of our knowledge, this is the first implementation of a port-separating, add-drop filter based on standing wave cavities coupled to conventional waveguides, and demonstrates a performance that suggests potential for photonic crystal devices within optical immersion lithography-based advanced CMOS electronics-photonics integration.

  3. Photothermally tunable silicon-microring-based optical add-drop filter through integrated light absorber.

    PubMed

    Chen, Xi; Shi, Yuechun; Lou, Fei; Chen, Yiting; Yan, Min; Wosinski, Lech; Qiu, Min

    2014-10-20

    An optically pumped thermo-optic (TO) silicon ring add-drop filter with fast thermal response is experimentally demonstrated. We propose that metal-insulator-metal (MIM) light absorber can be integrated into silicon TO devices, acting as a localized heat source which can be activated remotely by a pump beam. The MIM absorber design introduces less thermal capacity to the device, compared to conventional electrically-driven approaches. Experimentally, the absorber-integrated add-drop filter shows an optical response time of 13.7 μs following the 10%-90% rule (equivalent to a exponential time constant of 5 μs) and a wavelength shift over pump power of 60 pm/mW. The photothermally tunable add-drop filter may provide new perspectives for all-optical routing and switching in integrated Si photonic circuits.

  4. TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podgorsak, A; Bednarek, D; Rudin, S

    2016-06-15

    Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence.more » The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.« less

  5. Evaluation of a wireless activity monitoring system to quantify locomotor activity in horses in experimental settings.

    PubMed

    Fries, M; Montavon, S; Spadavecchia, C; Levionnois, O L

    2017-03-01

    Methods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively. To evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits. Observational study in an experimental setting. Dual-mode (activity and step count) piezo-electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland-Altman analysis and linear regression. The accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk. The dual-mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk. © 2016 EVJ Ltd.

  6. Identification and validation of nebulized aerosol devices for sputum induction

    PubMed Central

    Davidson, Warren J; Dennis, John; The, Stephanie; Litoski, Belinda; Pieron, Cora; Leigh, Richard

    2014-01-01

    Induced sputum cell count measurement has proven reliability for evaluating airway inflammation in patients with asthma and other airway diseases. Although the use of nebulizer devices for sputum induction is commonplace, they are generally labelled as single-patient devices by the manufacturer and, therefore, cannot be used for multiple patients in large clinical sputum induction programs due to infect ion-control requirements. Accordingly, this study investigated the aerosol characteristics of alternative devices that could be used in such programs. BACKGROUND: Induced sputum cell counts are a noninvasive and reliable method for evaluating the presence, type and degree of airway inflammation in patients with asthma. Currently, standard nebulizer devices used for sputum induction in multiple patients are labelled as single-patient devices by the manufacturer, which conflicts with infection prevention and control requirements. As such, these devices cannot feasibly be used in a clinical sputum induction program. Therefore, there is a need to identify alternative nebulizer devices that are either disposable or labelled for multi-patient use. OBJECTIVE: To apply validated rigorous, scientific testing methods to identify and validate commercially available nebulizer devices appropriate for use in a clinical sputum induction program. METHODS: Measurement of nebulized aerosol output and size for the selected nebulizer designs followed robust International Organization for Standardization methods. Sputum induction using two of these nebulizers was successfully performed on 10 healthy adult subjects. The cytotechnologist performing sputum cell counts was blinded to the type of nebulizer used. RESULTS: The studied nebulizers had variable aerosol outputs. The AeroNeb Solo (Aerogen, Ireland), Omron NE-U17 (Omron, Japan) and EASYneb II (Flaem Nuova, Italy) systems were found to have similar measurements of aerosol size. There was no significant difference in induced sputum cell results between the AeroNeb Solo and EASYneb II devices. DISCUSSION: There is a need for rigorous, scientific evaluation of nebulizer devices for clinical applications, including sputum induction, for measurement of cell counts. CONCLUSION: The present study was the most comprehensive analysis of different nebulizer devices for sputum induction to measure cell counts, and provides a framework for appropriate evaluation of nebulizer devices for induced sputum testing. PMID:24288700

  7. Love, Hate and Murder: Commitment Devices in Violent Relationships

    PubMed Central

    Aizer, Anna; Bó, Pedro Dal

    2009-01-01

    Many violent relationships are characterized by a high degree of cyclicality: women who are the victims of domestic violence often leave and return multiple times. To explain this we develop a model of time inconsistent preferences in the context of domestic violence. This time inconsistency generates a demand for commitment. We present supporting evidence that women in violent relationships display time inconsistent preferences by examining their demand for commitment devices. We find that no-drop policies – which compel the prosecutor to continue with prosecution even if the victim expresses a desire to drop the charges – result in an increase in reporting. No-drop policies also result in a decrease in the number of men murdered by intimates suggesting that some women in violent relationships move away from an extreme type of commitment device when a less costly one is offered. PMID:24244055

  8. Microprocessor controlled compliance monitor for eye drop medication

    PubMed Central

    Hermann, M M; Diestelhorst, M

    2006-01-01

    Background/aims The effectiveness of a self administered eye drop medication can only be assessed if the compliance is known. The authors studied the specificity and sensitivity of a new microprocessor controlled monitoring device. Methods The monitoring system was conducted by an 8 bit microcontroller for data acquisition and storage with sensors measuring applied pressure to the bottle, temperature, and vertical position. 10 devices were mounted under commercial 10 ml eye drops. Test subjects had to note down each application manually. A total of 15 applications each within 3 days was intended. Results Manual reports confirmed 15 applications for each of the 10 bottles. The monitoring devices detected a total of 149 events; one was missed; comprising a sensitivity of 99%. Two devices registered three applications, which did not appear in the manual protocols, indicating a specificity of about 98%. Refrigerated bottles were correctly identified. The battery lifetime exceeded 60 days. Conclusion The new monitoring device demonstrated a high reliability of the collected compliance data. The important, yet often unknown, influence of compliance in patient care and clinical trials shall be illuminated by the new device. This may lead to a better adapted patient care. Studies will profit from a higher credibility and results will be less influenced by non‐compliance. PMID:16540488

  9. A new primary mobility tool for the visually impaired: A white cane-adaptive mobility device hybrid.

    PubMed

    Rizzo, John-Ross; Conti, Kyle; Thomas, Teena; Hudson, Todd E; Wall Emerson, Robert; Kim, Dae Shik

    2017-05-16

    This article describes pilot testing of an adaptive mobility device-hybrid (AMD-H) combining properties of two primary mobility tools for people who are blind: the long cane and adaptive mobility devices (AMDs). The long cane is the primary mobility tool used by people who are blind and visually impaired for independent and safe mobility and AMDs are adaptive devices that are often lightweight frames approximately body width in lateral dimension that are simply pushed forward to clear the space in front of a person. The prototype cane built for this study had a wing apparatus that could be folded around the shaft of a cane but when unfolded, deployed two wheeled wings 25 cm (9.8 in) to each side of the canetip. This project explored drop-off and obstacle detection for 6 adults with visual impairment using the deployed AMD-H and a standard long cane. The AMD-H improved obstacle detection overall, and was most effective for the smallest obstacles (2 and 6 inch diameter). The AMD-H cut the average drop off threshold from 1.79 inches (4.55 cm) to .96 inches (2.44 cm). All participants showed a decrease in drop off detection threshold and an increase in detection rate (13.9% overall). For drop offs of 1 in (2.54 cm) and 3 in (7.62 cm), all participants showed large improvements with the AMD-H, ranging from 8.4 to 50%. The larger drop offs of 5 in (12.7 cm) and 7 in (17.8 cm) were well detected by both types of canes.

  10. The NASA, Marshall Space Flight Center drop tube user's manual

    NASA Technical Reports Server (NTRS)

    Rathz, Thomas J.; Robinson, Michael B.

    1990-01-01

    A comprehensive description of the structural and instrumentation hardware and the experimental capabilities of the 105-meter Marshall Space Flight Center Drop Tube Facility is given. This document is to serve as a guide to the investigator who wishes to perform materials processing experiments in the Drop Tube. Particular attention is given to the Tube's hardware to which an investigator must interface to perform experiments. This hardware consists of the permanent structural hardware (with such items as vacuum flanges), and the experimental hardware (with the furnaces and the sample insertion devices). Two furnaces, an electron-beam and an electromagnetic levitator, are currently used to melt metallic samples in a process environment that can range from 10(exp -6) Torr to 1 atmosphere. Details of these furnaces, the processing environment gases/vacuum, the electrical power, and data acquisition capabilities are specified to allow an investigator to design his/her experiment to maximize successful results and to reduce experimental setup time on the Tube. Various devices used to catch samples while inflicting minimum damage and to enhance turnaround time between experiments are described. Enough information is provided to allow an investigator who wishes to build his/her own furnace or sample catch devices to easily interface it to the Tube. The experimental instrumentation and data acquisition systems used to perform pre-drop and in-flight measurements of the melting and solidification process are also detailed. Typical experimental results are presented as an indicator of the type of data that is provided by the Drop Tube Facility. A summary bibliography of past Drop Tube experiments is provided, and an appendix explaining the noncontact temperature determination of free-falling drops is provided. This document is to be revised occasionally as improvements to the Facility are made and as the summary bibliography grows.

  11. Device For Controlling Crystallization Of Protein

    NASA Technical Reports Server (NTRS)

    Noever, David A.

    1993-01-01

    Variable sandwich spacer enables optimization of evaporative driving force that governs crystallization of protein from solution. Mechanically more rigid than hanging-drop and sitting-drop devices. Large oscillations and dislodgment of drop of solution in response to vibrations suppressed by glass plates. Other advantages include: suitable for automated delivery, stable handling, and programmable evaporation of protein solution; controlled configuration enables simple and accurate determination of volume of solution without disrupting crystallization; pH and concentration of precipitant controlled dynamically because pH and concentration coupled to rate of evaporation, controllable via adjustment of gap between plates; and enables variation of ratio between surface area and volume of protein solution. Alternative version, plates oriented vertically instead of horizontally.

  12. Radiation analysis devices, radiation analysis methods, and articles of manufacture

    DOEpatents

    Roybal, Lyle Gene

    2010-06-08

    Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.

  13. Variability of Seasonal CO2 Ice Caps on Mars for Mars Years 26 through 29

    NASA Astrophysics Data System (ADS)

    Feldman, W. C.; Maurice, S.; Prettyman, T. H.

    2011-12-01

    We have developed an improved thermal, epithermal, and fast neutron counting-rate time series data of the Mars Odyssey Neutron Spectrometer (MONS), optimized to greatly reduce both statistical and systematic uncertainties. This new data set was applied to study temporal and spatial distributions of the growth, decay, and maximum amount of precipitated CO2 ice during Martian years (MY) 26, 27, 28, and 29. For this study, we concentrate on the epithermal counting rate detected using the down-looking prism (P1) of MONS, and a combination of the epithermal and thermal counting rate detected by the forward-looking sensor (P2) of MONS. Although the energy range of neutrons detected by P2 covers both the thermal and epithermal range, it is heavily weighted to the thermal range. We find that the variance of the maximum epithermal counting rate is remarkably small over both north and south seasonal caps, varying by less than 3% over the four-year period. In contrast, although the maximum P2 counting rate over both poles is sensibly the same within error bars (about 2%) during the first three years, it drops by 18% over the north pole and 8% over the south pole during MY 29. The most-likely explanation of this drop is that abundances of the non-condensable gases N2 and Ar, are unusually enhanced during MY 29. Movies were also made of maps of the growth and decay of P2 counting rates summed over the first three years of these data. Careful inspection shows that both the growth and decay in the north were cylindrically symmetric, centered near the geographic north pole. In contrast, both the growth and decay of CO2 buildup in the south were skewed off the geographic pole to the center of the CO2 residual cap, and contained a small, but definitely distinct ring-like annular enhancement centered at a latitude of about 83.5° S spread over a longitude range that extends between about -35° and +35° E. This arc runs parallel to, and overlays, the very steep drop in altitude from the top of the south-polar CO2/water-ice residual cap at about +4.2 km to the surrounding plains at about +2.5 km. Algorithms developed previously to convert counting rates to CO2 and noncondensable gas column abundance will be applied to interpret the data.

  14. Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

    NASA Technical Reports Server (NTRS)

    Farr, William H.

    2009-01-01

    Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

  15. Comparison of 0.3% Hypotonic and Isotonic Sodium Hyaluronate Eye Drops in the Treatment of Experimental Dry Eye.

    PubMed

    Li, Ying; Cui, Lian; Lee, Hyo Seok; Kang, Yeon Soo; Choi, Won; Yoon, Kyung Chul

    2017-08-01

    To compare the efficacy of 0.3% hypotonic and isotonic sodium hyaluronate (SH) eye drops in the treatment of experimental dry eye. Experimental dry eye was established in female C57BL/6 mice by subcutaneous scopolamine injection and an air draft. The mice were divided into three groups (n = 15): control, preservative-free 0.3% isotonic SH, and preservative-free 0.3% hypotonic SH. The tear volume, tear film break-up time, and corneal fluorescein staining scores were measured 5 and 10 days after treatment. After conjunctival tissues were excised at 10 days, the levels of interleukin (IL)-6, IL-17, interferon (IFN)-γ, and IFN-γ inducible protein-10 were determined using the multiplex immunobead assay. In addition, PAS staining and flow cytometry were performed to evaluate the counts of conjunctival goblet cells and CD4+ IFN-γ+ T cells. Mice treated with 0.3% hypotonic SH showed a significant decrease in corneal staining scores (P = 0.04) and the levels of IL-6 (16.7 ± 1.4 pg/mL, P = 0.02) and IFN-γ (46.5 ± 11.5 pg/mL, P = 0.02) compared to mice treated with 0.3% isotonic SH (IL-6; 32.5 ± 8.8 pg/mL, IFN-γ; 92.0 ± 16.0 pg/mL) at day 10. Although no significant difference in CD4+ IFN-γ+ T cell numbers was observed, goblet cell counts were higher in the hyopotonic SH group than in the isotonic SH group (P = 0.02). When compared to 0.3% isotonic SH eye drops, 0.3% hypotonic SH eye drops can be more effective by improving corneal staining scores, decreasing inflammatory molecules, and increasing goblet cell counts for experimental dry eye. These data suggest that hypotonic artificial tears may be useful as an adjunctive treatment for inflammatory dry eye.

  16. TIME-INTERVAL MEASURING DEVICE

    DOEpatents

    Gross, J.E.

    1958-04-15

    An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.

  17. Hybrid optical fiber add-drop filter based on wavelength dependent light coupling between micro/nano fiber ring and side-polished fiber

    PubMed Central

    Yu, Jianhui; Jin, Shaoshen; Wei, Qingsong; Zang, Zhigang; Lu, Huihui; He, Xiaoli; Luo, Yunhan; Tang, Jieyuan; Zhang, Jun; Chen, Zhe

    2015-01-01

    In this paper, we report our experimental study on directly coupling a micro/nano fiber (MNOF) ring with a side-polished fiber(SPF). As a result of the study, the behavior of an add-drop filter was observed. The demonstrated add-drop filter explored the wavelength dependence of light coupling between a MNOF ring and a SPF. The characteristics of the filter and its performance dependence on the MNOF ring diameter were investigated experimentally. The investigation resulted in an empirically obtained ring diameter that showed relatively good filter performance. Since light coupling between a (MNOF) and a conventional single mode fiber has remained a challenge in the photonic integration community, the present study may provide an alternative way to couple light between a MNOF device and a conventional single mode fiber based device or system. The hybridization approach that uses a SPF as a platform to integrate a MNOF device may enable the realization of other all-fiber optical hybrid devices. PMID:25578467

  18. Study on molecular sieve absorption of ground state HF molecules in a non-chain pulsed HF Laser

    NASA Astrophysics Data System (ADS)

    Ma, Lianying; Zhou, Songqing; Chao, Huang; Huang, Ke; Zhu, Feng; Luan, Kunpeng; Chen, Hongwei

    2017-05-01

    This paper describes the principle of non-chain pulsed HF laser, and analyzes the reason why the laser energy dropped severely with the accumulation of shots when the HF laser was in repetitive operation. In order to solve this problem, a molecular sieve absorption device was designed and mounted in the recirculation loop of the HF laser. Measurements of flow velocity indicated that the absorption device would just introduce a small decrease of flow velocity which would not influence the laser operation. Several types of molecular sieve (3A,4A,5A,13X) were used in absorbing experiments and the experiment results inferred that 3A molecular sieve was the most effective sorbent. All the experiments showed that the average drop of the output energy was not more than 5% after 1000 shots at 50Hz/20s. Compared to the energy drop of about 40% without the device, the absorption device could significantly improve the stability of the HF laser output energy and prolong the lifespan of laser medium gases.

  19. A valid and reliable method to measure jump-specific training and competition load in elite volleyball players.

    PubMed

    Skazalski, C; Whiteley, R; Hansen, C; Bahr, R

    2018-05-01

    Use of a commercially available wearable device to monitor jump load with elite volleyball players has become common practice. The purpose of this study was to evaluate the validity and reliability of this device, the Vert, to count jumps and measure jump height with professional volleyball players. Jump count accuracy was determined by comparing jumps recorded by the device to jumps observed through systematic video analysis of three practice sessions and two league matches performed by a men's professional volleyball team. Jumps performed by 14 players were each coded for time and jump type and individually matched to device recorded jumps. Jump height validity of the device was examined against reference standards as participants performed countermovement jumps on a force plate and volleyball-specific jumps with a Vertec. The Vert device accurately counted 99.3% of the 3637 jumps performed during practice and match play. The device showed excellent jump height interdevice reliability for two devices placed in the same pouch during volleyball jumps (r = .99, 95% CI 0.98-0.99). The device had a minimum detectable change (MDC) of 9.7 cm and overestimated jump height by an average of 5.5 cm (95% CI 4.5-6.5) across all volleyball jumps. The Vert device demonstrates excellent accuracy counting volleyball-specific jumps during training and competition. While the device is not recommended to measure maximal jumping ability when precision is needed, it provides an acceptable measure of on-court jump height that can be used to monitor athlete jump load. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting.

    PubMed

    Treacy, Daniel; Hassett, Leanne; Schurr, Karl; Chagpar, Sakina; Paul, Serene S; Sherrington, Catherine

    2017-05-01

    Commonly used activity monitors have been shown to be accurate in counting steps in active people; however, further validation is needed in slower walking populations. To determine the validity of activity monitors for measuring step counts in rehabilitation inpatients compared with visually observed step counts. To explore the influence of gait parameters, activity monitor position, and use of walkers on activity monitor accuracy. One hundred and sixty-six inpatients admitted to a rehabilitation unit with an average walking speed of 0.4 m/s (SD 0.2) wore 16 activity monitors (7 different devices in different positions) simultaneously during 6-minute and 6-m walks. The number of steps taken during the tests was also counted by a physical therapist. Gait parameters were assessed using the GAITRite system. To analyze the influence of different gait parameters, the percentage accuracy for each monitor was graphed against various gait parameters for each activity monitor. The StepWatch, Fitbit One worn on the ankle and the ActivPAL showed excellent agreement with observed step count (ICC 2,1 0.98; 0.92; 0.78 respectively). Other devices (Fitbit Charge, Fitbit One worn on hip, G-Sensor, Garmin Vivofit, Actigraph) showed poor agreement with the observed step count (ICC 2,1 0.12-0.40). Percentage agreement with observed step count was highest for the StepWatch (mean 98%). The StepWatch and the Fitbit One worn on the ankle maintained accuracy in individuals who walked more slowly and with shorter strides but other devices were less accurate in these individuals. There were small numbers of participants for some gait parameters. The StepWatch showed the highest accuracy and closest agreement with observed step count. This device can be confidently used by researchers for accurate measurement of step counts in inpatient rehabilitation in individuals who walk slowly. If immediate feedback is desired, the Fitbit One when worn on the ankle would be the best choice for this population. © 2017 American Physical Therapy Association

  1. Convergent-Filament Nonmechanical Pump

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1989-01-01

    Simple device induces small flow of liquid without help of moving parts, in presence or absence of gravity. Drops of liquid move on filaments from wide end of cone to narrow end. Gradually blend with drops on adjacent filaments to form large drops with menisci. Important use expected to be returning liquid condensate in heat pipes, and collection of samples from clouds or fog.

  2. Cavity optomechanics in a levitated helium drop

    NASA Astrophysics Data System (ADS)

    Childress, L.; Schmidt, M. P.; Kashkanova, A. D.; Brown, C. D.; Harris, G. I.; Aiello, A.; Marquardt, F.; Harris, J. G. E.

    2017-12-01

    We describe a proposal for a type of optomechanical system based on a drop of liquid helium that is magnetically levitated in vacuum. In the proposed device, the drop would serve three roles: its optical whispering-gallery modes would provide the optical cavity, its surface vibrations would constitute the mechanical element, and evaporation of He atoms from its surface would provide continuous refrigeration. We analyze the feasibility of such a system in light of previous experimental demonstrations of its essential components: magnetic levitation of mm-scale and cm-scale drops of liquid He , evaporative cooling of He droplets in vacuum, and coupling to high-quality optical whispering-gallery modes in a wide range of liquids. We find that the combination of these features could result in a device that approaches the single-photon strong-coupling regime, due to the high optical quality factors attainable at low temperatures. Moreover, the system offers a unique opportunity to use optical techniques to study the motion of a superfluid that is freely levitating in vacuum (in the case of 4He). Alternatively, for a normal fluid drop of 3He, we propose to exploit the coupling between the drop's rotations and vibrations to perform quantum nondemolition measurements of angular momentum.

  3. 21 CFR 864.8175 - Calibrator for platelet counting.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...

  4. 21 CFR 864.8175 - Calibrator for platelet counting.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...

  5. 21 CFR 864.8175 - Calibrator for platelet counting.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...

  6. 21 CFR 864.8175 - Calibrator for platelet counting.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...

  7. 21 CFR 864.8175 - Calibrator for platelet counting.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...

  8. Laser multiplexing system

    DOEpatents

    Johnson, Steve A.; English, Jr., Ronald Edward; White, Ronald K.

    2001-01-01

    A plurality of copper lasers, as radiant power sources, emits a beam of power carrying radiation. A plurality of fiber injection assemblies receives power from the plurality of copper lasers and injects such power into a plurality of fibers for individually transmitting the received power to a plurality of power-receiving devices. The power-transmitting fibers of the system are so arranged that power is delivered therethrough to each of the power-receiving devices such that, even if a few of the radiant power sources and/or fibers fail, the power supply to any of the power receiving devices will not completely drop to zero but will drop by the same proportionate amount.

  9. A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps

    PubMed Central

    Dittler, Ina; Dornfeld, Wolfgang; Schöb, Reto; Cocke, Jared; Rojahn, Jürgen; Kraume, Matthias; Eibl, Dieter

    2015-01-01

    Pumps are mainly used when transferring sterile culture broths in biopharmaceutical and biotechnological production processes. However, during the pumping process shear forces occur which can lead to qualitative and/or quantitative product loss. To calculate the mechanical stress with limited experimental expense, an oil-water emulsion system was used, whose suitability was demonstrated for drop size detections in bioreactors1. As drop breakup of the oil-water emulsion system is a function of mechanical stress, drop sizes need to be counted over the experimental time of shear stress investigations. In previous studies, the inline endoscopy has been shown to be an accurate and reliable measurement technique for drop size detections in liquid/liquid dispersions. The aim of this protocol is to show the suitability of the inline endoscopy technique for drop size measurements in pumping processes. In order to express the drop size, the Sauter mean diameter d32 was used as the representative diameter of drops in the oil-water emulsion. The results showed low variation in the Sauter mean diameters, which were quantified by standard deviations of below 15%, indicating the reliability of the measurement technique. PMID:26274765

  10. Drop foot corrective device

    NASA Technical Reports Server (NTRS)

    Deis, B. C. (Inventor)

    1986-01-01

    A light weight, economical device to alleviate a plurality of difficulties encountered in walking by a victim suffering from a drop foot condition is discussed. A legband girdles the leg below the knee and above the calf providing an anchor point for the upper end of a ligament having its lower end attached to a toe of a shoe or a toe on the foot. The ligament is of such length that the foot is supported thereby and retained in a normal position during walking.

  11. Blast Mitigation Seat Analysis - Assessment of the Effect of Personal Protective Equipment on the 5th Percentile Female Anthropomorphic Test Devices Performance in Drop Tower Evaluations (Briefing Charts)

    DTIC Science & Technology

    2015-08-01

    for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data ...sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden...UNCLASSIFIED UNCLASSIFIED • Baseline drop tower data collected from Anthropomorphic Test Devices (ATDs) seated in 12 models of Commercial Off-The-Shelf

  12. Droplet-counting Microtitration System for Precise On-site Analysis.

    PubMed

    Kawakubo, Susumu; Omori, Taichi; Suzuki, Yasutada; Ueta, Ikuo

    2018-01-01

    A new microtitration system based on the counting of titrant droplets has been developed for precise on-site analysis. The dropping rate was controlled by inserting a capillary tube as a flow resistance in a laboratory-made micropipette. The error of titration was 3% in a simulated titration with 20 droplets. The pre-addition of a titrant was proposed for precise titration within an error of 0.5%. The analytical performances were evaluated for chelate titration, redox titration and acid-base titration.

  13. Optimization of high count rate event counting detector with Microchannel Plates and quad Timepix readout

    NASA Astrophysics Data System (ADS)

    Tremsin, A. S.; Vallerga, J. V.; McPhate, J. B.; Siegmund, O. H. W.

    2015-07-01

    Many high resolution event counting devices process one event at a time and cannot register simultaneous events. In this article a frame-based readout event counting detector consisting of a pair of Microchannel Plates and a quad Timepix readout is described. More than 104 simultaneous events can be detected with a spatial resolution of 55 μm, while >103 simultaneous events can be detected with <10 μm spatial resolution when event centroiding is implemented. The fast readout electronics is capable of processing >1200 frames/sec, while the global count rate of the detector can exceed 5×108 particles/s when no timing information on every particle is required. For the first generation Timepix readout, the timing resolution is limited by the Timepix clock to 10-20 ns. Optimization of the MCP gain, rear field voltage and Timepix threshold levels are crucial for the device performance and that is the main subject of this article. These devices can be very attractive for applications where the photon/electron/ion/neutron counting with high spatial and temporal resolution is required, such as energy resolved neutron imaging, Time of Flight experiments in lidar applications, experiments on photoelectron spectroscopy and many others.

  14. Increased drop formation frequency via reduction of surfactant interactions in flow-focusing microfluidic devices.

    PubMed

    Josephides, Dimitris N; Sajjadi, Shahriar

    2015-01-27

    Glass capillary based microfluidic devices are able to create extremely uniform droplets, when formed under the dripping regime, at low setup costs due to their ease of manufacture. However, as they are rarely parallelized, simple methods to increase droplet production from a single device are sought. Surfactants used to stabilize drops in such systems often limit the maximum flow rate that highly uniform drops can be produced due to the lowering interfacial tension causing jetting. In this paper we show that by simple design changes we can limit the interactions of surfactants and maximize uniform droplet production. Three flow-focused configurations are explored: a standard glass capillary device (consisting of a single round capillary inserted into a square capillary), a nozzle fed device, and a surfactant shielding device (both consisting of two round capillaries inserted into either end of a square capillary). In principle, the maximum productivity of uniform droplets is achieved if surfactants are not present. It was found that surfactants in the standard device greatly inhibit droplet production by means of interfacial tension lowering and tip-streaming phenomena. In the nozzle fed configuration, surfactant interactions were greatly limited, yielding flow rates comparable to, but lower than, a surfactant-free system. In the surfactant shielding configuration, flow rates were equal to that of a surfactant-free system and could make uniform droplets at rates an order of magnitude above the standard surfactant system.

  15. Self-bonded composite films based on cellulose nanofibers and chitin nanocrystals as antifungal materials.

    PubMed

    Robles, Eduardo; Salaberria, Asier M; Herrera, Rene; Fernandes, Susana C M; Labidi, Jalel

    2016-06-25

    Cellulose nanofibers and chitin nanocrystals, two main components of agricultural and aquacultural by-products, were obtained from blue agave and yellow squat lobster industrial residues. Cellulose nanofibers were obtained using high pressure homogenization, while chitin nanocrystals were obtained by hydrolysis in acid medium. Cellulose nanofibers and chitin nanocrystals were characterized by X-ray diffraction, Atomic Force Microscopy and Infrared spectroscopy. Self-bonded composite films with different composition were fabricated by hot pressing and their properties were evaluated. Antifungal activity of chitin nanocrystals was studied using a Cellometer(®) cell count device, mechanical properties at tension were measured with a universal testing machine, water vapor permeability was evaluated with a thermohygrometer and surface tension with sessile drop contact angle method. The addition of chitin nanocrystals reduced slightly the mechanical properties of the composite. Presence of chitin nanocrystals influenced the growth of Aspergillus sp fungus in the surface of the composites as expected. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Successful use of the Cryolock device for cryopreservation of scarce human ejaculate and testicular spermatozoa.

    PubMed

    Stein, A; Shufaro, Y; Hadar, S; Fisch, B; Pinkas, H

    2015-03-01

    The existing methods for cryopreservation of very low count sperm samples are complex and sub-optimal for individual spermatozoa. Our purpose is to establish an effective simple method for cryoprotecting individual spermatozoa. Samples from patients with OTA were mixed with TYB or HEPES-buffered salt solution with glycerol + glucose and placed on a Cryolock that was plunged directly into liquid nitrogen or exposed to its vapors. Thawing was performed by direct immersion into a drop of warmed medium. The favorable method was tested on diluted samples (10-50 cells) and leftover TESE specimens from patients with azoospermia. Cryopreservation was considered successful if >30 spermatozoa, (>3 motile), or >5 spermatozoa (>1 motile) in diluted and TESE samples, were detected post-thawing. A significantly higher survival rate of seminal spermatozoa was obtained when using the Cryolock with TYB and freezing with liquid nitrogen vapor, compared to HEPES glycerol-glucose (95 vs. 35% respectively). Plunging the Cryolock into liquid nitrogen was detrimental. Cryolock combined with TYB cryoprotection and liquid nitrogen vapor freezing was highly effective for cryopreservation of individual spermatozoa in diluted and TESE samples. The Cryolock may serve for freezing very low-count sperm samples and individual spermatozoa. This method offers simplicity, efficacy, use of available materials, without requiring micromanipulation equipment or skills. © 2015 American Society of Andrology and European Academy of Andrology.

  17. Effect of the helically-trapped energetic-ion-driven resistive interchange modes on energetic ion confinement in the Large Helical Device

    NASA Astrophysics Data System (ADS)

    Ogawa, K.; Isobe, M.; Kawase, H.; Nishitani, T.; Seki, R.; Osakabe, M.; LHD Experiment Group

    2018-04-01

    The effect of the helically-trapped energetic-ion-driven resistive interchange modes (EICs) on energetic ion confinement is studied in the Large Helical Device deuterium plasmas. Neutron diagnostics such as the neutron flux monitor and the vertical neutron camera (VNC) are used in order to measure neutrons mainly created by beam-plasma reactions. The line-integrated neutron profiles are obtained by VNC in magnetohydrodynamic-quiet plasma with various neutral beam (NB) injection patterns. The profiles are consistent with that expected by the beam ion density calculated using orbit-following simulations. Significant decreases of the total neutron emission rate (S n) and the neutron counting rate of the VNC (C n) in central cords are observed to be synchronized with EIC bursts with perpendicular-NB injection. The drop rates of both S n and C n increase with EIC amplitude and reach around 50%. The line-integrated neutron profiles before and after EIC burst show that in the central cords, C n decrease due to EIC burst whereas there is almost no change in the other cords. The experimental results suggests that the effect of EIC on helically-trapped beam ion is substantial, however the effect of passing beam ion is not significant.

  18. Comparison of high speed DI-LIGBT structures

    NASA Astrophysics Data System (ADS)

    Sunkavalli, Ravishankar; Baliga, B. Jayant

    1997-12-01

    The performance of the DI segmented collector (SC)-LIGBT is compared to the collector shorted (CS)-LIGBT. The SC-LIGBT allows for adjusting the tradeoff between switching speed and on-state voltage drop by simply changing the P+ collector segment width during device layout. In contrast to previously reported junction isolated (JI) devices, the DI SC-LIGBT was observed to have a turnoff speed similar to the CS-LIGBT with a higher forward drop than the conventional LIGBT. The on-state performance of the integral diodes of the SC-LIGBTs was found to be superior to the integral diode of the CS-LIGBT. The integral diodes of both the CS and the SC-LIGBTs were found to have much superior switching characteristics compared to a lateral PiN diode at the expense of a higher on-state voltage drop. Thus, the superior switching characteristics of the integral diode in the SC-LIGBT complements its fast switching behavior making this device attractive for compact, high frequency, high efficient, power ICs.

  19. Droplet trapping and fast acoustic release in a multi-height device with steady-state flow.

    PubMed

    Rambach, Richard W; Linder, Kevin; Heymann, Michael; Franke, Thomas

    2017-10-11

    We demonstrate a novel multilayer polydimethylsiloxane (PDMS) device for selective storage and release of single emulsion droplets. Drops are captured in a microchannel cavity and can be released on-demand through a triggered surface acoustic wave pulse. The surface acoustic wave (SAW) is excited by a tapered interdigital transducer (TIDT) deposited on a piezoelectric lithium niobate (LiNbO 3 ) substrate and inverts the pressure difference across the cavity trap to push a drop out of the trap and back into the main flow channel. Droplet capture and release does not require a flow rate change, flow interruption, flow inversion or valve action and can be achieved in as fast as 20 ms. This allows both on-demand droplet capture for analysis and monitoring over arbitrary time scales, and continuous device operation with a high droplet rate of 620 drops per s. We hence decouple long-term droplet interrogation from other operations on the chip. This will ease integration with other microfluidic droplet operations and functional components.

  20. A multi-channel clogging-resistant lab-on-a-chip cell counter and analyzer

    NASA Astrophysics Data System (ADS)

    Dai, Jie; Chiu, Yu-Jui; Lian, Ian; Wu, Tsung-Feng; Yang, Kecheng; Lo, Yu-Hwa

    2016-02-01

    Early signs of diseases can be revealed from cell detection in biofluids, such as detection of white blood cells (WBCs) in the peritoneal fluid for peritonitis. A lab-on-a-chip microfluidic device offers an attractive platform for such applications because of its small size, low cost, and ease of use provided the device can meet the performance requirements which many existing LoC devices fail to satisfy. We report an integrated microfluidic device capable of accurately counting low concentration of white blood cells in peritoneal fluid at 150 μl min-1 to offer an accurate (<3% error) and fast (~10 min/run) WBC count. Utilizing the self-regulating hydrodynamic properties and a unique architecture in the design, the device can achieve higher flow rate (500-1000 μl min-1), continuous running for over 5 h without clogging, as well as excellent signal quality for unambiguous WBC count and WBC classification for certain diseases. These properties make the device a promising candidate for point-of-care applications.

  1. Randomised controlled trial of topical antibacterial Manuka (Leptospermum species) honey for evaporative dry eye due to meibomian gland dysfunction.

    PubMed

    Albietz, Julie M; Schmid, Katrina L

    2017-11-01

    The aim was to evaluate the efficacy of standardised Manuka (Leptospermum species) antibacterial honey as adjunctive twice daily treatment to conventional therapy (warm compresses, lid massage and preservative-free lubricant), in participants with evaporative dry eye due to moderate to advanced meibomian gland dysfunction. This prospective, open-label study involved 114 participants. After two weeks of conventional therapy participants were randomised to one of three treatment groups: Optimel Antibacterial Manuka Eye Gel (98 per cent Leptospermum species honey) plus conventional therapy (n = 37), Optimel Manuka plus Lubricant Eye Drops (16 per cent Leptospermum species honey) plus conventional therapy (n = 37) and a control (conventional therapy) (n = 40). Clinical evaluations performed at baseline and Week 8 included: symptom scores (Ocular Surface Disease Index, Ocular Comfort Index), daily lubricant use, tear assessments (break-up time, secretion, osmolarity and InflammaDry), corneal sensation, ocular surface staining, meibomian gland secretion quality and expressibility, bulbar conjunctival, limbal and lid marginal redness and eyelid marginal bacterial cultures and colony counts. Significant improvements (p ≤ 0.05) occurred at Week 8 in symptoms, tear break-up time, staining, tear osmolarity, meibum quality and bulbar, limbal and lid margin redness for all treatments. Improvement in staining was significantly greater with Optimel 16 per cent drops (p = 0.035). Significant improvements (p < 0.05) in meibomian gland expressibility and InflammaDry occurred for both Optimel treatments. Optimel 98 per cent gel was significantly more effective in improving meibum quality (p = 0.005) and gland expressibility (p = 0.042). Total eyelid marginal bacterial colony counts reduced significantly with Optimel 16 per cent drops (p = 0.03) but not the other treatments. Staphylococcus epidermidis counts reduced significantly with Optimel 16 per cent drops (p = 0.041) and Optimel 98 per cent gel (p = 0.027). Both Optimel treatments significantly reduced the need for lubricants, with Optimel 16 per cent drops decreasing lubricant use most (p = 0.001). Temporary redness and stinging were the only adverse effects of Optimel use. Optimel antibacterial honey treatments are effective as adjunctive therapies for meibomian gland dysfunction. © 2017 Optometry Australia.

  2. Droplet microfluidics driven by gradients of confinement.

    PubMed

    Dangla, Rémi; Kayi, S Cagri; Baroud, Charles N

    2013-01-15

    The miniaturization of droplet manipulation methods has led to drops being proposed as microreactors in many applications of biology and chemistry. In parallel, microfluidic methods have been applied to generate monodisperse emulsions for applications in the pharmaceuticals, cosmetics, and food industries. To date, microfluidic droplet production has been dominated by a few designs that use hydrodynamic forces, resulting from the flowing fluids, to break drops at a junction. Here we present a platform for droplet generation and manipulation that does not depend on the fluid flows. Instead, we use devices that incorporate height variations to subject the immiscible interfaces to gradients of confinement. The resulting curvature imbalance along the interface causes the detachment of monodisperse droplets, without the need for a flow of the external phase. Once detached, the drops are self-propelled due to the gradient of surface energy. We show that the size of the drops is determined by the device geometry; it is insensitive to the physical fluid properties and depends very weakly on the flow rate of the dispersed phase. This allows us to propose a geometric theoretical model that predicts the dependence of droplet size on the geometric parameters, which is in agreement with experimental measurements. The approach presented here can be applied in a wide range of standard applications, while simplifying the device operations. We demonstrate examples for single-droplet operations and high-throughput generation of emulsions, all of which are performed in simple and inexpensive devices.

  3. Droplet microfluidics driven by gradients of confinement

    PubMed Central

    Dangla, Rémi; Kayi, S. Cagri; Baroud, Charles N.

    2013-01-01

    The miniaturization of droplet manipulation methods has led to drops being proposed as microreactors in many applications of biology and chemistry. In parallel, microfluidic methods have been applied to generate monodisperse emulsions for applications in the pharmaceuticals, cosmetics, and food industries. To date, microfluidic droplet production has been dominated by a few designs that use hydrodynamic forces, resulting from the flowing fluids, to break drops at a junction. Here we present a platform for droplet generation and manipulation that does not depend on the fluid flows. Instead, we use devices that incorporate height variations to subject the immiscible interfaces to gradients of confinement. The resulting curvature imbalance along the interface causes the detachment of monodisperse droplets, without the need for a flow of the external phase. Once detached, the drops are self-propelled due to the gradient of surface energy. We show that the size of the drops is determined by the device geometry; it is insensitive to the physical fluid properties and depends very weakly on the flow rate of the dispersed phase. This allows us to propose a geometric theoretical model that predicts the dependence of droplet size on the geometric parameters, which is in agreement with experimental measurements. The approach presented here can be applied in a wide range of standard applications, while simplifying the device operations. We demonstrate examples for single-droplet operations and high-throughput generation of emulsions, all of which are performed in simple and inexpensive devices. PMID:23284169

  4. Ceramic microparticles and capsules via microfluidic processing of a preceramic polymer

    PubMed Central

    Ye, Congwang; Chen, Anthony; Colombo, Paolo; Martinez, Carlos

    2010-01-01

    We have developed a robust technique to fabricate monodispersed solid and porous ceramic particles and capsules from single and double emulsion drops composed of silsesquioxane preceramic polymer. A microcapillary microfluidic device was used to generate the monodispersed drops. In this device, two round capillaries are aligned facing each other inside a square capillary. Three fluids are needed to generate the double emulsions. The inner fluid, which flows through the input capillary, and the middle fluid, which flows through the void space between the square and inner fluid capillaries, form a coaxial co-flow in a direction that is opposite to the flow of the outer fluid. As the three fluids are forced through the exit capillary, the inner and middle fluids break into monodispersed double emulsion drops in a single-step process, at rates of up to 2000 drops s−1. Once the drops are generated, the silsesquioxane is cross-linked in solution and the cross-linked particles are dried and pyrolysed in an inert atmosphere to form oxycarbide glass particles. Particles with diameters ranging from 30 to 180 µm, shell thicknesses ranging from 10 to 50 µm and shell pore diameters ranging from 1 to 10 µm were easily prepared by changing fluid flow rates, device dimensions and fluid composition. The produced particles and capsules can be used in their polymeric state or pyrolysed to ceramic. This technique can be extended to other preceramic polymers and can be used to generate unique core–shell multimaterial particles. PMID:20484226

  5. Ceramic microparticles and capsules via microfluidic processing of a preceramic polymer.

    PubMed

    Ye, Congwang; Chen, Anthony; Colombo, Paolo; Martinez, Carlos

    2010-08-06

    We have developed a robust technique to fabricate monodispersed solid and porous ceramic particles and capsules from single and double emulsion drops composed of silsesquioxane preceramic polymer. A microcapillary microfluidic device was used to generate the monodispersed drops. In this device, two round capillaries are aligned facing each other inside a square capillary. Three fluids are needed to generate the double emulsions. The inner fluid, which flows through the input capillary, and the middle fluid, which flows through the void space between the square and inner fluid capillaries, form a coaxial co-flow in a direction that is opposite to the flow of the outer fluid. As the three fluids are forced through the exit capillary, the inner and middle fluids break into monodispersed double emulsion drops in a single-step process, at rates of up to 2000 drops s(-1). Once the drops are generated, the silsesquioxane is cross-linked in solution and the cross-linked particles are dried and pyrolysed in an inert atmosphere to form oxycarbide glass particles. Particles with diameters ranging from 30 to 180 microm, shell thicknesses ranging from 10 to 50 microm and shell pore diameters ranging from 1 to 10 microm were easily prepared by changing fluid flow rates, device dimensions and fluid composition. The produced particles and capsules can be used in their polymeric state or pyrolysed to ceramic. This technique can be extended to other preceramic polymers and can be used to generate unique core-shell multimaterial particles.

  6. Objective assessment of activity in older adults at risk for mobility disability.

    PubMed

    Marsh, Anthony P; Vance, Rachel M; Frederick, Tera L; Hesselmann, Sarah A; Rejeski, W Jack

    2007-06-01

    The purpose of this study was to evaluate the validity of three objective measures of physical activity (Accusplit Eagle 120 mechanical pedometer (AE120), NL-2000 electronic pedometer, and IDEEA pattern-recognition device) that varied in their levels of sophistication, among older adults at risk for mobility disability. In addition, we examined the potential influences of gait speed and body mass index (BMI) on step count accuracy. Step counts recorded on the three devices were compared against manual step counts made by two investigators as each participant walked 131 m around an indoor track at their preferred walking speed (N=29; 75.8+/-4.2 yr). Gait speed was determined by dividing total distance walked by time to completion. BMI was calculated from height and body mass measurements. All three devices significantly underestimated steps taken (AE120=22.8+/-53.9 steps; NL-2000=4.0+/-5.8 steps; IDEEA=5.6+/-7.8 steps), but there was no significant difference between devices (P=0.084). Steps counted by the AE120, NL-2000, and IDEEA were significantly correlated with manual step counts (r=0.508, 0.980, and 0.965, respectively; P

  7. Ultrasonic Substrate Vibration-Assisted Drop Casting (SVADC) for the Fabrication of Photovoltaic Solar Cell Arrays and Thin-Film Devices.

    PubMed

    Eslamian, Morteza; Zabihi, Fatemeh

    2015-12-01

    A simple, low-cost, versatile, and potentially scalable casting method is proposed for the fabrication of micro- and nano-thin films, herein termed as ultrasonic "substrate vibration-assisted drop casting" (SVADC). The impingement of a solution drop onto a substrate in a simple process called drop casting, usually results in spreading of the liquid solution and the formation of a non-uniform thin solid film after solvent evaporation. Our previous and current supporting results, as well as few similar reports by others, confirm that imposing ultrasonic vibration on the substrate can simply convert the uncontrollable drop casting method into a controllable coating technique. Therefore, the SVADC may be used to fabricate an array of emerging thin-film solar cells, such as polymer, perovskite, and quantum-dot solar cells, as well as other small thin-film devices, in a roll-to-roll and automated fabrication process. The preliminary results demonstrate a ten-fold increase in electrical conductivity of PSS made by SVADC compared with the film made by conventional drop casting. Also, simple planar perovskite solar cells made here using SVADC show promising performance with an efficiency of over 3 % for a simple structure without performing process optimization or using expensive materials and treatments.

  8. HIGH VOLTAGE GENERATOR

    DOEpatents

    Zito, G.V.

    1959-04-21

    This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

  9. Body Temperature during Hibernation Is Highly Correlated with a Decrease in Circulating Innate Immune Cells in the Brown Bear (Ursus arctos): A Common Feature among Hibernators?

    PubMed Central

    Sahdo, Berolla; Evans, Alina L.; Arnemo, Jon M.; Fröbert, Ole; Särndahl, Eva; Blanc, Stéphane

    2013-01-01

    Background: Hibernation involves periods of severely depressed metabolism (torpor) and decreases in body temperature (Tb). Small arctic mammals (<5kg), in which Tb generally drop drastically, display leukopenia during hibernation. This raised the question of whether the decreased leukocyte counts in mammalian hibernators is due to torpor per se or is secondary to low Tb. The present study examined immune cell counts in brown bears (Ursus arctos), where torpor is only associated with shallow decreases in Tb. The results were compared across hibernator species for which immune and Tb data were available. Methods and Results: The white blood cell counts were determined by flow cytometry in 13 bears captured in the field both during summer and winter over 2 years time. Tb dropped from 39.6±0.8 to 33.5±1.1°C during hibernation. Blood neutrophils and monocytes were lower during hibernation than during the active period (47%, p= 0.001; 43%, p=0.039, respectively), whereas no change in lymphocyte counts was detected (p=0.599). Further, combining our data and those from 10 studies on 9 hibernating species suggested that the decline in Tb explained the decrease in innate immune cells (R2=0.83, p<0.0001). Conclusions: Bears have fewer innate immune cells in circulation during hibernation, which may represent a suppressed innate immune system. Across species comparison suggests that, both in small and large hibernators, Tb is the main driver of immune function regulation during winter dormancy. The lack of a difference in lymphocyte counts in this context requires further investigations. PMID:23532623

  10. Body temperature during hibernation is highly correlated with a decrease in circulating innate immune cells in the brown bear (Ursus arctos): a common feature among hibernators?

    PubMed

    Sahdo, Berolla; Evans, Alina L; Arnemo, Jon M; Fröbert, Ole; Särndahl, Eva; Blanc, Stéphane

    2013-01-01

    Hibernation involves periods of severely depressed metabolism (torpor) and decreases in body temperature (Tb). Small arctic mammals (<5kg), in which Tb generally drop drastically, display leukopenia during hibernation. This raised the question of whether the decreased leukocyte counts in mammalian hibernators is due to torpor per se or is secondary to low Tb. The present study examined immune cell counts in brown bears (Ursus arctos), where torpor is only associated with shallow decreases in Tb. The results were compared across hibernator species for which immune and Tb data were available. The white blood cell counts were determined by flow cytometry in 13 bears captured in the field both during summer and winter over 2 years time. Tb dropped from 39.6±0.8 to 33.5±1.1°C during hibernation. Blood neutrophils and monocytes were lower during hibernation than during the active period (47%, p= 0.001; 43%, p=0.039, respectively), whereas no change in lymphocyte counts was detected (p=0.599). Further, combining our data and those from 10 studies on 9 hibernating species suggested that the decline in Tb explained the decrease in innate immune cells (R(2)=0.83, p<0.0001). Bears have fewer innate immune cells in circulation during hibernation, which may represent a suppressed innate immune system. Across species comparison suggests that, both in small and large hibernators, Tb is the main driver of immune function regulation during winter dormancy. The lack of a difference in lymphocyte counts in this context requires further investigations.

  11. Prognostic health monitoring in switch-mode power supplies with voltage regulation

    NASA Technical Reports Server (NTRS)

    Hofmeister, James P (Inventor); Judkins, Justin B (Inventor)

    2009-01-01

    The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

  12. A third-order silicon racetrack add-drop filter with a moderate feature size

    NASA Astrophysics Data System (ADS)

    Wang, Ying; Zhou, Xin; Chen, Qian; Shao, Yue; Chen, Xiangning; Huang, Qingzhong; Jiang, Wei

    2018-01-01

    In this work, we design and fabricate a highly compact third-order racetrack add-drop filter consisting of silicon waveguides with modified widths on a silicon-on-insulator (SOI) wafer. Compared to the previous approach that requires an exceedingly narrow coupling gap less than 100nm, we propose a new approach that enlarges the minimum feature size of the whole device to be 300 nm to reduce the process requirement. The three-dimensional finite-difference time-domain (3D-FDTD) method is used for simulation. Experiment results show good agreement with simulation results in property. In the experiment, the filter shows a nearly box-like channel dropping response, which has a large flat 3-dB bandwidth ({3 nm), relatively large FSR ({13.3 nm) and out-of-band rejection larger than 14 dB at the drop port with a footprint of 0.0006 mm2 . The device is small and simple enough to have a wide range of applications in large scale on-chip photonic integration circuits.

  13. Droplet morphometry and velocimetry (DMV): a video processing software for time-resolved, label-free tracking of droplet parameters.

    PubMed

    Basu, Amar S

    2013-05-21

    Emerging assays in droplet microfluidics require the measurement of parameters such as drop size, velocity, trajectory, shape deformation, fluorescence intensity, and others. While micro particle image velocimetry (μPIV) and related techniques are suitable for measuring flow using tracer particles, no tool exists for tracking droplets at the granularity of a single entity. This paper presents droplet morphometry and velocimetry (DMV), a digital video processing software for time-resolved droplet analysis. Droplets are identified through a series of image processing steps which operate on transparent, translucent, fluorescent, or opaque droplets. The steps include background image generation, background subtraction, edge detection, small object removal, morphological close and fill, and shape discrimination. A frame correlation step then links droplets spanning multiple frames via a nearest neighbor search with user-defined matching criteria. Each step can be individually tuned for maximum compatibility. For each droplet found, DMV provides a time-history of 20 different parameters, including trajectory, velocity, area, dimensions, shape deformation, orientation, nearest neighbour spacing, and pixel statistics. The data can be reported via scatter plots, histograms, and tables at the granularity of individual droplets or by statistics accrued over the population. We present several case studies from industry and academic labs, including the measurement of 1) size distributions and flow perturbations in a drop generator, 2) size distributions and mixing rates in drop splitting/merging devices, 3) efficiency of single cell encapsulation devices, 4) position tracking in electrowetting operations, 5) chemical concentrations in a serial drop dilutor, 6) drop sorting efficiency of a tensiophoresis device, 7) plug length and orientation of nonspherical plugs in a serpentine channel, and 8) high throughput tracking of >250 drops in a reinjection system. Performance metrics show that highest accuracy and precision is obtained when the video resolution is >300 pixels per drop. Analysis time increases proportionally with video resolution. The current version of the software provides throughputs of 2-30 fps, suggesting the potential for real time analysis.

  14. Biofouling detection monitoring devices: status assessment. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillman, R.E.; Anson, D.; Corliss, J.M.

    1985-03-01

    An inventory of devices to detect and monitor biofouling in power plant condenser systems was prepared. The inventory was developed through a review of manufacturers' product information brochures, a general literature review, and limited personal contact with users and manufacturers. Two macrofouling and seventeen microfouling detection devices were reviewed. A summary analysis of the principal features of each device was prepared. Macrofouling devices are generally simple devices located at or near cooling water intakes. They monitor the growth of larger organisms such as mussels, barnacles, and large seaweeds. Microfouling detectors are usually located in or near the condenser tubes. Theymore » detect and monitor the growth of slime films on the tubes. Some of the devices measure changes in heat transfer or pressure drop in the condenser tubes. Other types include condenser simulators, biofilm samplers, or devices that measure the acoustic properties of the fouling films. Most devices are still in the development stage. Of the few available for general use, the type that measures heat transfer and/or pressure drop are developed to a greater degree than the other types. Recommendations for further research into development of a biofouling detection and monitoring devices include a side-by-side field comparison of selected devices, and the continued development of an effective acoustic device.« less

  15. Low-Voltage Bypass Device

    NASA Technical Reports Server (NTRS)

    Wilson, J. P.

    1994-01-01

    Improved bypass device provides low-resistance current shunt around low-voltage power cell when cell fails in open-circuit condition during operation. In comparison with older bypass devices for same application, this one weighs less, generates less heat, and has lower voltage drop (less resistance). Bypass device connected in parallel with power cell. Draws very little current during normal operation of cell.

  16. Reducing cyclone pressure drop with evasés

    USDA-ARS?s Scientific Manuscript database

    Cyclones are widely used to separate particles from gas flows and as air emissions control devices. Their cost of operation is proportional to the fan energy required to overcome their pressure drop. Evasés or exit diffusers potentially could reduce exit pressure losses without affecting collection...

  17. Investigation of the quality of stored red blood cells after simulated air drop in the maritime environment.

    PubMed

    Meli, Athinoula; Hancock, Vicky; Doughty, Heidi; Smedley, Steve; Cardigan, Rebecca; Wiltshire, Michael

    2018-02-01

    Maritime medical capability may be compromised by blood resupply. Air-dropped red blood cells (RBCs) is a possible mitigation factor. This study set out to evaluate RBC storage variables after a simulated parachute air drop into the sea, as limited data exist. The air load construction for the air drop of blood was subject to static drop assessment to simulate a worst-case parachute drop scenario. One control and two test Golden Hour shipping containers were each packaged with 10 RBC units. The control box was not dropped; Test Boxes 1 and 2 were further reinforced with waterproof boxes and underwent a simulated air drop on Day 7 or Day 8 postdonation, respectively. One day after the drop and once a week thereafter until Day 43 of storage, RBCs from each box were sampled and tested for full blood counts, hemolysis, adenosine triphosphate, 2,3-diphosphoglycerate, pH, extracellular potassium, glucose, lactate, deformability, and RBC microvesicles. The packaging configuration completed the air drop with no water ingress or physical damage. All units met UK specifications for volume, hemoglobin, and hemolysis. There were no significant differences for any of the variables studied between RBCs in the control box compared to RBCs in Test Boxes 1 and 2 combined over storage. The test proved that the packaging solution and the impact of a maritime air drop as performed in this study, on Day 7 or Day 8 postdonation, did not affect the in vitro quality of RBCs in SAGM over storage for 35 days. © 2017 AABB.

  18. Using Commercial Activity Monitors to Measure Gait in Patients with Suspected iNPH: Implications for Ambulatory Monitoring

    PubMed Central

    Gaglani, Shiv; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele

    2015-01-01

    Objectives: This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. Methods: This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Results: Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. Conclusions: These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested. PMID:26719825

  19. Using Commercial Activity Monitors to Measure Gait in Patients with Suspected iNPH: Implications for Ambulatory Monitoring.

    PubMed

    Gaglani, Shiv; Moore, Jessica; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele

    2015-11-17

    This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested.

  20. Electrohydrodynamic generation of millimetric drops and control of electrification

    NASA Astrophysics Data System (ADS)

    Yun, Sungchan

    2017-07-01

    We report a simple method for millimetric drop generation by electrohydrodynamic (EHD) detachment using a conventional nozzle-ring device. The EHD detachment method provides distinct features of uniform-size and controlled electrification of millimetric drops. The drop dynamics of detachment and shape oscillation are recorded using a high-speed camera and analyzed for several dc voltages applied to the electrode. Experimental studies show that an oscillation frequency can be closely related to the amount of electric charge, which can be explained based on both effective interfacial tension and inviscid Rayleigh and Lamb frequency. Furthermore, we present a concept to generate a neutral drop by adjusting the duration time of a pulse signal and discuss a drop oscillation induced by the detachment. This study can provide potential implications for drop manipulation, such as transporting, merging, and mixing, in microfluidic platforms.

  1. Wavelength division multiplexed and double-port pumped time-bin entangled photon pair generation using Si ring resonator.

    PubMed

    Fujiwara, Mikio; Wakabayashi, Ryota; Sasaki, Masahide; Takeoka, Masahiro

    2017-02-20

    We report a wavelength division multiplexed time-bin entangled photon pair source in telecom wavelength using a 10 μm radius Si ring resonator. This compact resonator has two add ports and two drop ports. By pumping one add port by a continuous laser, we demonstrate an efficient generation of two-wavelength division multiplexed time-bin entangled photon pairs in the telecom C-band, which come out of one drop port, and are then split into the signal and idler photons via a wavelength filter. The resonator structure enhances four-wave mixing for pair generation. Moreover, we demonstrate the double-port pumping where two counter propagating pump lights are injected to generate entanglement from the two drop ports simultaneously. We successfully observe the highly entangled outputs from both two drop ports. Surprisingly, the count rate at each drop port is even increased by twice that of the single-port pumping. Possible mechanisms of this observation are discussed. Our technique allows for the efficient use of the Si ring resonator and widens its functionality for variety of applications.

  2. Droplet combustion at reduced gravity

    NASA Technical Reports Server (NTRS)

    Dryer, F. L.; Williams, F. A.

    1988-01-01

    The current work involves theoretical analyses of the effects identified, experiments in the NASA Lewis drop towers performed in the middeck areas of the Space Shuttle. In addition, there is laboratory work associated with the design of the flight apparatus. Calculations have shown that some of the test-matrix data can be obtained in drop towers, and some are achievable only in the space experiments. The apparatus consists of a droplet dispensing device (syringes), a droplet positioning device (opposing, retractable, hollow needles), a droplet ignition device (two matched pairs of retractable spark electrodes), gas and liquid handling systems, a data acquisition system (mainly giving motion-picture records of the combustion in two orthogonal views, one with backlighting for droplet resolution), and associated electronics.

  3. Investigation of transport properties of coronene.TCNQ cocrystal microrods with coronene microrods and TCNQ microsheets

    NASA Astrophysics Data System (ADS)

    Wu, Hao-Di; Wang, Feng-Xia; Zhang, Meng; Pan, Ge-Bo

    2015-07-01

    Coronene.TCNQ cocrystal microrods, coronene microrods, and TCNQ microsheets were constructed by a drop-casting method. Prototype devices were fabricated and their field-effect-transistor (FET) performances were investigated. It is found that coronene.TCNQ microrods had exhibited an n-type characteristic and showed better FET performances than TCNQ microsheets.Coronene.TCNQ cocrystal microrods, coronene microrods, and TCNQ microsheets were constructed by a drop-casting method. Prototype devices were fabricated and their field-effect-transistor (FET) performances were investigated. It is found that coronene.TCNQ microrods had exhibited an n-type characteristic and showed better FET performances than TCNQ microsheets. Electronic supplementary information (ESI) available: Device fabrication and measurements. See DOI: 10.1039/c5nr02778k

  4. 14 CFR 29.725 - Limit drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... energy absorbing devices or by the use of an effective mass. (c) Each landing gear unit must be tested in the attitude simulating the landing condition that is most critical from the standpoint of the energy...-up attitude considered in the nose-up landing conditions. h=specified free drop height (inches). L...

  5. 14 CFR 29.725 - Limit drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... energy absorbing devices or by the use of an effective mass. (c) Each landing gear unit must be tested in the attitude simulating the landing condition that is most critical from the standpoint of the energy...-up attitude considered in the nose-up landing conditions. h=specified free drop height (inches). L...

  6. Responsivity drop due to conductance modulation in GaN metal-semiconductor-metal Schottky based UV photodetectors on Si(111)

    NASA Astrophysics Data System (ADS)

    Ravikiran, L.; Radhakrishnan, K.; Dharmarasu, N.; Agrawal, M.; Wang, Zilong; Bruno, Annalisa; Soci, Cesare; Lihuang, Tng; Kian Siong, Ang

    2016-09-01

    GaN Schottky metal-semiconductor-metal (MSM) UV photodetectors were fabricated on a 600 nm thick GaN layer, grown on 100 mm Si (111) substrate using an ammonia-MBE growth technique. In this report, the effect of device dimensions, applied bias and input power on the linearity of the GaN Schottky-based MSM photodetectors on Si substrate were investigated. Devices with larger interdigitated spacing, ‘S’ of 9.0 μm between the fingers resulted in good linearity and flat responsivity characteristics as a function of input power with an external quantum efficiency (EQE) of ˜33% at an applied bias of 15 V and an input power of 0.8 W m-2. With the decrease of ‘S’ to 3.0 μm, the EQE was found to increase to ˜97%. However, devices showed non linearity and drop in responsivity from flatness at higher input power. Moreover, the position of dropping from flatter responsivity was found to shift to lower powers with increased bias. The drop in the responsivity was attributed to the modulation of conductance in the MSM due to the trapping of electrons at the dislocations, resulting in the formation of depletion regions around them. In devices with lower ‘S’, both the image force reduction and the enhanced collection efficiency increased the photocurrent as well as the charging of the dislocations. This resulted in the increased depletion regions around the dislocations leading to the modulation of conductance and non-linearity.

  7. Velocity overshoot decay mechanisms in compound semiconductor field-effect transistors with a submicron characteristic length

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jyegal, Jang, E-mail: jjyegal@inu.ac.kr

    Velocity overshoot is a critically important nonstationary effect utilized for the enhanced performance of submicron field-effect devices fabricated with high-electron-mobility compound semiconductors. However, the physical mechanisms of velocity overshoot decay dynamics in the devices are not known in detail. Therefore, a numerical analysis is conducted typically for a submicron GaAs metal-semiconductor field-effect transistor in order to elucidate the physical mechanisms. It is found that there exist three different mechanisms, depending on device bias conditions. Specifically, at large drain biases corresponding to the saturation drain current (dc) region, the velocity overshoot suddenly begins to drop very sensitively due to the onsetmore » of a rapid decrease of the momentum relaxation time, not the mobility, arising from the effect of velocity-randomizing intervalley scattering. It then continues to drop rapidly and decays completely by severe mobility reduction due to intervalley scattering. On the other hand, at small drain biases corresponding to the linear dc region, the velocity overshoot suddenly begins to drop very sensitively due to the onset of a rapid increase of thermal energy diffusion by electrons in the channel of the gate. It then continues to drop rapidly for a certain channel distance due to the increasing thermal energy diffusion effect, and later completely decays by a sharply decreasing electric field. Moreover, at drain biases close to a dc saturation voltage, the mechanism is a mixture of the above two bias conditions. It is suggested that a large secondary-valley energy separation is essential to increase the performance of submicron devices.« less

  8. Characterization of Acousto-Electric Cluster and Array Levitation and its Application to Evaporation

    NASA Technical Reports Server (NTRS)

    Robert E. Apfel; Zheng, Yibing

    2000-01-01

    An acousto-electric levitator has been developed to study the behavior of liquid drop and solid particle clusters and arrays. Unlike an ordinary acoustic levitator that uses only a standing acoustic wave to levitate a single drop or particle, this device uses an extra electric static field and the acoustic field simultaneously to generate and levitate charged drops in two-dimensional arrays in air without any contact to a solid surface. This cluster and array generation (CAG) instrument enables us to steadily position drops and arrays to study the behavior of multiple drop and particle systems such as spray and aerosol systems relevant to the energy, environmental, and material sciences.

  9. Ultrasmall multi-channel resonant-tunneling filter using mode gap of width-tuned photonic-crystal waveguide.

    PubMed

    Shinya, Akihiko; Mitsugi, Satoshi; Kuramochi, Eiichi; Notomi, Masaya

    2005-05-30

    We have devised an ultra-small multi-channel drop filter based on a two-port resonant tunneling system in a two-dimensional photonic crystal with a triangular air-hole lattice. This filter does not require careful consideration of the interference process to achieve a high dropping efficiency. First we develop three-port systems based on a two-port resonant tunneling filter. Next we devise a multi-port channel drop filter by cascading these three-port systems. In this paper, we demonstrate a ten-channel drop filter with an 18 mum device size by 2D-FDTD calculation, and a three-port resonant tunneling filter with 65+/- 20 % dropping efficiency by experiment.

  10. Boron selenide semiconductor detectors for thermal neutron counting

    NASA Astrophysics Data System (ADS)

    Kargar, Alireza; Tower, Joshua; Cirignano, Leonard; Shah, Kanai

    2013-09-01

    Thermal neutron detectors in planar configuration were fabricated from B2Se3 (Boron Selenide) crystals grown at RMD Inc. All fabricated semiconductor devices were characterized for the current-voltage (I-V) characteristic and neutron counting measurement. In this study, the resistivity of crystals is reported and the collected pulse height spectra are presented for devices irradiated with the 241AmBe neutron source. Long-term stability of the B2Se3 devices for neutron detection under continuous bias and without being under continuous bias was investigated and the results are reported. The B2Se3 devices showed response to thermal neutrons of the 241AmBe source.

  11. Technical Requirements for On-Site Thermal Desorption of Solid Media Contaminated with Hazardous Chlorinated Organics

    DTIC Science & Technology

    1997-09-18

    scrubbers , detectable dioxin/furans may occur, since dioxin/furans are much more soluble in organics than in water. Carbon adsorption is frequently...air pollution control device is required. Acid gases may be controlled by using a wet or dry scrubber or by using a coated baghouse. Operating...unit: 1. exit treated waste temperature; 2. baghouse pressure drop, venturi pressure drop, or drop in liquid/gas ratio; 3. waste feed rate; 4

  12. Mechanisms of Exhaust Pollutants and Plume Formation in Continuous Combustion.

    DTIC Science & Technology

    1984-11-30

    drop swirler. A swirled air inlet decreased flame length . Two modes of operation were observed. At higher fuel loadings, reaction could be initiated...and maintained in the recirculation zone in the shadow of the step. The net result was a shorter overall flame length . The low-pressure drop swirler...yielded a shorter flame length relative to the higher pressure drop devices. - • u mmm m -m~amkn Jm• ml AM mmmmm TABLE OF CONTENTS Section Title Page

  13. Automatic safety rod for reactors. [LMFBR

    DOEpatents

    Germer, J.H.

    1982-03-23

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  14. Automatic safety rod for reactors

    DOEpatents

    Germer, John H.

    1988-01-01

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-core flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  15. Imaging visible light with Medipix2.

    PubMed

    Mac Raighne, Aaron; Brownlee, Colin; Gebert, Ulrike; Maneuski, Dzmitry; Milnes, James; O'Shea, Val; Rügheimer, Tilman K

    2010-11-01

    A need exists for high-speed single-photon counting optical imaging detectors. Single-photon counting high-speed detection of x rays is possible by using Medipix2 with pixelated silicon photodiodes. In this article, we report on a device that exploits the Medipix2 chip for optical imaging. The fabricated device is capable of imaging at >3000 frames/s over a 256×256 pixel matrix. The imaging performance of the detector device via the modulation transfer function is measured, and the presence of ion feedback and its degradation of the imaging properties are discussed.

  16. 21 CFR 864.8185 - Calibrator for red cell and white cell counting.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibrator for red cell and white cell counting...

  17. 21 CFR 864.8185 - Calibrator for red cell and white cell counting.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibrator for red cell and white cell counting...

  18. 21 CFR 864.8185 - Calibrator for red cell and white cell counting.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibrator for red cell and white cell counting...

  19. 21 CFR 864.8185 - Calibrator for red cell and white cell counting.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibrator for red cell and white cell counting...

  20. 21 CFR 864.8185 - Calibrator for red cell and white cell counting.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for red cell and white cell counting... Calibrator for red cell and white cell counting. (a) Identification. A calibrator for red cell and white cell counting is a device that resembles red or white blood cells and that is used to set instruments intended...

  1. Genetic diversity of Diporeia in the Great Lakes: comparison of Lake Superior to the other Great Lakes

    EPA Science Inventory

    Abundances of Diporeia have dropped drastically in the Great Lakes, except in Lake Superior, where data suggest that population counts actually have risen. Various ecological, environmental, or geographic hypotheses have been proposed to explain the greater abundance of Lake Supe...

  2. Blast Mitigation Sea Analysis - Evaluation of Lumbar Compression Data Trends in 5th Percentile Female Anthropomorphic Test Device Performance Compared to 50th Percentile Male Anthropomorphic Test Device in Drop Tower Testing

    DTIC Science & Technology

    2016-08-21

    less pronounced for pelvis velocity • Seat velocity and dynamic displacement not recorded for this test series – Would provide key information for...effectiveness of seat – Displacement /time history data should be recorded for all future test series UNCLASSIFIED UNCLASSIFIED Conclusions/Future...interfacing with seat manufacturers to broaden occupant protection range – Record dynamic stroke on all drop tower tests to evaluate correlation between displacement rate and lumbar compression UNCLASSIFIED UNCLASSIFIED 17

  3. Effects of an implantable two-channel peroneal nerve stimulator versus conventional walking device on spatiotemporal parameters and kinematics of hemiparetic gait.

    PubMed

    Kottink, Anke I R; Tenniglo, Martin J B; de Vries, Wiebe H K; Hermens, Hermie J; Buurke, Jaap H

    2012-01-01

    The aims of this study were: (i) to compare the neuro-prosthetic effect of implantable peroneal nerve stimulation to the orthotic effect of a standard of care intervention (no device, shoe or ankle foot orthosis) on walking, as assessed by spatiotemporal parameters; and (ii) to examine whether there is evidence of an enhanced lower-limb flexion reflex with peroneal nerve stimulation and compare the kinematic effect of an implantable peroneal nerve stimulation device vs standard of care intervention on initial loading response of the paretic limb, as assessed by hip, knee and ankle kinematics. Randomized controlled trial. A total of 23 chronic stroke survivors with drop foot. The intervention group received an implantable 2-channel peroneal nerve stimulator for correction of drop foot. The control group continued using a conventional walking device. Spatiotemporal parameters and hip, knee and ankle kinematics were measured while subjects walked with the device on using a 3-dimensional video camera system during baseline and after a follow-up period of 26 weeks. Peroneal nerve stimulation normalized stance and double support of the paretic limb and single support of the non-paretic limb, in comparison with using a conventional walking device. In addition, peroneal nerve stimulation is more effective to provide ankle dorsiflexion during swing and resulted in a normalized initial loading response. Although peroneal nerve stimulation and ankle foot orthosis are both prescribed to correct a drop foot in the same patient population, spatiotemporal parameters, dorsiflexion during swing and loading response are influenced in a functionally different way.

  4. Effects of drop acceleration and deceleration on particle capture in a cross-flow gravity tower at intermediate drop Reynolds numbers.

    PubMed

    Kumar, Anoop; Gupta, S K; Kale, S R

    2007-04-01

    Cross-flow gravity towers are particle scrubbing devices in which water is sprayed from the top into particle-laden flow moving horizontally. Models for predicting particle capture assume drops traveling at terminal velocity and potential flow (ReD > 1000) around it, however, Reynolds numbers in the intermediate range of 1 to 1000 are common in gravity towers. Drops are usually injected at velocities greater than their terminal velocities (as in nozzles) or from near rest (perforated tray) and they accelerate/decelerate to their terminal velocity in the tower. Also, the effects of intermediate drop Reynolds number on capture efficiency have been simulated for (a) drops at their terminal velocity and (b) drops accelerating/decelerating to their terminal velocity. Tower efficiency based on potential flow about the drop is 40%-50% greater than for 200 mm drops traveling at their terminal velocity. The corresponding values for 500 mm drops are about 10%-20%. The drop injection velocity is important operating parameter. Increase in tower efficiency by about 40% for particles smaller than 5 mm is observed for increase in injection velocity from 0 to 20 m/s for 200 and 500mm drops.

  5. 40 CFR Table 4 of Subpart Aaaaaaa... - Operating Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Roofing Manufacturing Other Requirements and Information Who implements and enforces this subpart? Pt. 63... filter or fiber bed filter a. Inlet gas temperature b, andb. Pressure drop across device b The 3-hour... temperature and pressure drop, you can use a leak detection system that identifies when the filter media has...

  6. 40 CFR Table 4 of Subpart Aaaaaaa... - Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Roofing Manufacturing Other Requirements and Information Who implements and enforces this subpart? Pt. 63... filter or fiber bed filter a. Inlet gas temperature b, andb. Pressure drop across device b The 3-hour... temperature and pressure drop, you can use a leak detection system that identifies when the filter media has...

  7. Playing with Water Drops: From Wetting to Optics through Electrostatics

    ERIC Educational Resources Information Center

    Domps, A.; Roques-Carmes, T.

    2011-01-01

    We present a consistent series of activities, including experiments and basic computational studies, investigating the shape and optical properties of water drops in connection with novel technological devices. Most of the work can be carried out with simple teaching equipment and is well suited to undergraduate students. Firstly, we show how the…

  8. 14 CFR 29.725 - Limit drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Landing Gear § 29.725 Limit drop test. The... energy absorbing devices or by the use of an effective mass. (c) Each landing gear unit must be tested in... to be absorbed by it. (d) When an effective mass is used in showing compliance with paragraph (b) of...

  9. Seamless Combination of Fluorescence-Activated Cell Sorting and Hanging-Drop Networks for Individual Handling and Culturing of Stem Cells and Microtissue Spheroids.

    PubMed

    Birchler, Axel; Berger, Mischa; Jäggin, Verena; Lopes, Telma; Etzrodt, Martin; Misun, Patrick Mark; Pena-Francesch, Maria; Schroeder, Timm; Hierlemann, Andreas; Frey, Olivier

    2016-01-19

    Open microfluidic cell culturing devices offer new possibilities to simplify loading, culturing, and harvesting of individual cells or microtissues due to the fact that liquids and cells/microtissues are directly accessible. We present a complete workflow for microfluidic handling and culturing of individual cells and microtissue spheroids, which is based on the hanging-drop network concept: The open microfluidic devices are seamlessly combined with fluorescence-activated cell sorting (FACS), so that individual cells, including stem cells, can be directly sorted into specified culturing compartments in a fully automated way and at high accuracy. Moreover, already assembled microtissue spheroids can be loaded into the microfluidic structures by using a conventional pipet. Cell and microtissue culturing is then performed in hanging drops under controlled perfusion. On-chip drop size control measures were applied to stabilize the system. Cells and microtissue spheroids can be retrieved from the chip by using a parallelized transfer method. The presented methodology holds great promise for combinatorial screening of stem-cell and multicellular-spheroid cultures.

  10. The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures

    NASA Astrophysics Data System (ADS)

    Stephenson, W. Kirk

    2009-08-01

    A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes.

  11. Video-Recorded Validation of Wearable Step Counters under Free-living Conditions.

    PubMed

    Toth, Lindsay P; Park, Susan; Springer, Cary M; Feyerabend, McKenzie D; Steeves, Jeremy A; Bassett, David R

    2018-06-01

    The purpose of this study was to determine the accuracy of 14-step counting methods under free-living conditions. Twelve adults (mean ± SD age, 35 ± 13 yr) wore a chest harness that held a GoPro camera pointed down at the feet during all waking hours for 1 d. The GoPro continuously recorded video of all steps taken throughout the day. Simultaneously, participants wore two StepWatch (SW) devices on each ankle (all programmed with different settings), one activPAL on each thigh, four devices at the waist (Fitbit Zip, Yamax Digi-Walker SW-200, New Lifestyles NL-2000, and ActiGraph GT9X (AG)), and two devices on the dominant and nondominant wrists (Fitbit Charge and AG). The GoPro videos were downloaded to a computer and researchers counted steps using a hand tally device, which served as the criterion method. The SW devices recorded between 95.3% and 102.8% of actual steps taken throughout the day (P > 0.05). Eleven step counting methods estimated less than 100% of actual steps; Fitbit Zip, Yamax Digi-Walker SW-200, and AG with the moving average vector magnitude algorithm on both wrists recorded 71% to 91% of steps (P > 0.05), whereas the activPAL, New Lifestyles NL-2000, and AG (without low-frequency extension (no-LFE), moving average vector magnitude) worn on the hip, and Fitbit Charge recorded 69% to 84% of steps (P < 0.05). Five methods estimated more than 100% of actual steps; AG (no-LFE) on both wrists recorded 109% to 122% of steps (P > 0.05), whereas the AG (LFE) on both wrists and the hip recorded 128% to 220% of steps (P < 0.05). Across all waking hours of 1 d, step counts differ between devices. The SW, regardless of settings, was the most accurate method of counting steps.

  12. DIME Participant Builds a Potential Drop Tower Candidate

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A student assembles a Lego (TM) Challenge device designed to operate in the portable drop tower demonstrator as part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  13. 10 CFR 32.101 - Schedule B-prototype tests for luminous safety devices for use in aircraft.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Schedule B-prototype tests for luminous safety devices for... thermometer. (d) Shock test. The device shall be dropped upon a concrete or iron surface in a 3-foot free gravitational fall, or shall be subjected to equivalent treatment in a test device simulating such a free fall...

  14. Drop deformation and breakup in a partially filled horizontal rotating cylinder

    NASA Astrophysics Data System (ADS)

    White, Andrew; Pereira, Caroline; Hyacinthe, Hyaquino; Ward, Thomas

    2014-11-01

    Drop deformation and breakup due to shear flow has been studied extensively in Couette devices as well as in gravity-driven flows. In these cases shear is generated either by the moving wall or the drop's motion. For such flows the drop shape remains unperturbed at low capillary number (Ca), deforms at moderate Ca , and can experience breakup as Ca --> 1 and larger. Here single drops of NaOH(aq) will be placed in a horizontal cylindrical rotating tank partially filled with vegetable oil resulting in 10-2 < Ca <101 . It will be shown that the reactive vegetable oil-NaOH(aq) system, where surfactants are produced in situ by saponification, can yield lower minimum surface tensions and faster adsorption than non-reactive surfactant systems. Oil films between the wall and drop as well as drop shape will be observed as rotation rates and NaOH(aq) concentration are varied. Results will be presented in the context of previous work on bubble and drop shapes and breakup. NSF CBET #1262718.

  15. OpenDrop: An Integrated Do-It-Yourself Platform for Personal Use of Biochips

    PubMed Central

    Alistar, Mirela; Gaudenz, Urs

    2017-01-01

    Biochips, or digital labs-on-chip, are developed with the purpose of being used by laboratory technicians or biologists in laboratories or clinics. In this article, we expand this vision with the goal of enabling everyone, regardless of their expertise, to use biochips for their own personal purposes. We developed OpenDrop, an integrated electromicrofluidic platform that allows users to develop and program their own bio-applications. We address the main challenges that users may encounter: accessibility, bio-protocol design and interaction with microfluidics. OpenDrop consists of a do-it-yourself biochip, an automated software tool with visual interface and a detailed technique for at-home operations of microfluidics. We report on two years of use of OpenDrop, released as an open-source platform. Our platform attracted a highly diverse user base with participants originating from maker communities, academia and industry. Our findings show that 47% of attempts to replicate OpenDrop were successful, the main challenge remaining the assembly of the device. In terms of usability, the users managed to operate their platforms at home and are working on designing their own bio-applications. Our work provides a step towards a future in which everyone will be able to create microfluidic devices for their personal applications, thereby democratizing parts of health care. PMID:28952524

  16. Implementation of a protocol for assembling DNA in a Teflon tube

    NASA Astrophysics Data System (ADS)

    Walsh, Edmond J.; Feuerborn, Alexander; Cook, Peter R.

    2017-02-01

    Droplet based microfluidics continues to grow as a platform for chemical and biological reactions using small quantities of fluids, however complex protocols are rarely possible in existing devices. This paper implements a new approach to merging of drops, combined with magnetic bead manipulation, for the creation of ligated double-stranded DNA molecule using "Gibson assembly" chemistry. DNA assembly is initially accomplished through the merging, and mixing, of five drops followed by a thermal cycle. Then, integrating this drop merging method with magnetic beads enable the implementation of amore complete protocol consisting of nine wash steps,merging of four drop, transport of selective reagents between twelve drops using magnetic particles, followed by a thermal cycle and finally the deposition of a purified drop into an Eppendorf for downstream analysis. Gel electrophoresis is used to confirm successful DNA assembly.

  17. Mobile Device Accuracy for Step Counting Across Age Groups

    PubMed Central

    Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W

    2017-01-01

    Background Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. Objective We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. Methods We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Results Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly undercounted steps for the group ranging from 65-84 years. Conclusions Our analysis shows that apart from the Fitbit Surge, most of the recent mobile devices we tested do not overcount or undercount steps in the 18-39-year-old age group, however some devices undercount steps in older age groups. This finding suggests that accuracy in step counting may be an issue with some popular wearable devices, and that age may be a factor in undercounting. These results are particularly important for clinical interventions using such devices and other activity trackers, in particular to balance energy requirements with energy expenditure in the context of a weight loss intervention program. PMID:28659255

  18. Single photon counting linear mode avalanche photodiode technologies

    NASA Astrophysics Data System (ADS)

    Williams, George M.; Huntington, Andrew S.

    2011-10-01

    The false count rate of a single-photon-sensitive photoreceiver consisting of a high-gain, low-excess-noise linear-mode InGaAs avalanche photodiode (APD) and a high-bandwidth transimpedance amplifier (TIA) is fit to a statistical model. The peak height distribution of the APD's multiplied dark current is approximated by the weighted sum of McIntyre distributions, each characterizing dark current generated at a different location within the APD's junction. The peak height distribution approximated in this way is convolved with a Gaussian distribution representing the input-referred noise of the TIA to generate the statistical distribution of the uncorrelated sum. The cumulative distribution function (CDF) representing count probability as a function of detection threshold is computed, and the CDF model fit to empirical false count data. It is found that only k=0 McIntyre distributions fit the empirically measured CDF at high detection threshold, and that false count rate drops faster than photon count rate as detection threshold is raised. Once fit to empirical false count data, the model predicts the improvement of the false count rate to be expected from reductions in TIA noise and APD dark current. Improvement by at least three orders of magnitude is thought feasible with further manufacturing development and a capacitive-feedback TIA (CTIA).

  19. Single photon detection using Geiger mode CMOS avalanche photodiodes

    NASA Astrophysics Data System (ADS)

    Lawrence, William G.; Stapels, Christopher; Augustine, Frank L.; Christian, James F.

    2005-10-01

    Geiger mode Avalanche Photodiodes fabricated using complementary metal-oxide-semiconductor (CMOS) fabrication technology combine high sensitivity detectors with pixel-level auxiliary circuitry. Radiation Monitoring Devices has successfully implemented CMOS manufacturing techniques to develop prototype detectors with active diameters ranging from 5 to 60 microns and measured detection efficiencies of up to 60%. CMOS active quenching circuits are included in the pixel layout. The actively quenched pixels have a quenching time less than 30 ns and a maximum count rate greater than 10 MHz. The actively quenched Geiger mode avalanche photodiode (GPD) has linear response at room temperature over six orders of magnitude. When operating in Geiger mode, these GPDs act as single photon-counting detectors that produce a digital output pulse for each photon with no associated read noise. Thermoelectrically cooled detectors have less than 1 Hz dark counts. The detection efficiency, dark count rate, and after-pulsing of two different pixel designs are measured and demonstrate the differences in the device operation. Additional applications for these devices include nuclear imaging and replacement of photomultiplier tubes in dosimeters.

  20. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    PubMed

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid

    2009-04-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  1. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    PubMed

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; OLaighin, Gearoid

    2007-01-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor based foot switches and NMES based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  2. A precise goniometer/tensiometer using a low cost single-board computer

    NASA Astrophysics Data System (ADS)

    Favier, Benoit; Chamakos, Nikolaos T.; Papathanasiou, Athanasios G.

    2017-12-01

    Measuring the surface tension and the Young contact angle of a droplet is extremely important for many industrial applications. Here, considering the booming interest for small and cheap but precise experimental instruments, we have constructed a low-cost contact angle goniometer/tensiometer, based on a single-board computer (Raspberry Pi). The device runs an axisymmetric drop shape analysis (ADSA) algorithm written in Python. The code, here named DropToolKit, was developed in-house. We initially present the mathematical framework of our algorithm and then we validate our software tool against other well-established ADSA packages, including the commercial ramé-hart DROPimage Advanced as well as the DropAnalysis plugin in ImageJ. After successfully testing for various combinations of liquids and solid surfaces, we concluded that our prototype device would be highly beneficial for industrial applications as well as for scientific research in wetting phenomena compared to the commercial solutions.

  3. Transport Powder and Liquid Samples by Surface Acoustic Waves

    NASA Technical Reports Server (NTRS)

    Bao, Xiaoqi; Bar-Cohen, Yoseph; Sherrit, Stewart; Badescu, Mircea; Louyeh, Sahar

    2009-01-01

    Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.

  4. Cerebrovascular accidents in patients with a ventricular assist device.

    PubMed

    Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L

    2007-07-01

    A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P < .0001). Sixty-six percent of cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.

  5. Getting something out of nothing in the measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Tan, Yong-Gang; Cai, Qing-Yu; Yang, Hai-Feng; Hu, Yao-Hua

    2015-11-01

    Because of the monogamy of entanglement, the measurement-device-independent quantum key distribution is immune to the side-information leaking of the measurement devices. When the correlated measurement outcomes are generated from the dark counts, no entanglement is actually obtained. However, secure key bits can still be proven to be generated from these measurement outcomes. Especially, we will give numerical studies on the contributions of dark counts to the key generation rate in practical decoy state MDI-QKD where a signal source, a weaker decoy source and a vacuum decoy source are used by either legitimate key distributer.

  6. The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures

    ERIC Educational Resources Information Center

    Stephenson, W. Kirk

    2009-01-01

    A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)

  7. High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device

    DOEpatents

    Atac, M.; McKay, T.A.

    1998-04-21

    An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.

  8. High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device

    DOEpatents

    Atac, Muzaffer; McKay, Timothy A.

    1998-01-01

    An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.

  9. Every Drop Counts for Parched Campuses

    ERIC Educational Resources Information Center

    Mangan, Katherine

    2008-01-01

    As north Georgia continues to experience its worst drought in more than a century, many colleges in the region are struggling with water woes, with some seeking lessons from colleges that have survived droughts before. Climatologists say that the drought may intensify this spring and summer, and that emergency measures are overdue. Now that the…

  10. Design and evaluation of a nondestructive fissile assay device for HTGR fuel samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNeany, S. R.; Knoll, R. W.; Jenkins, J. D.

    1979-02-01

    Nondestructive assay of fissile material plays an important role in nuclear fuel processing facilities. Information for product quality control, plant criticality safety, and nuclear materials accountability can be obtained from assay devices. All of this is necessary for a safe, efficient, and orderly operation of a production plant. Presented here is a design description and an operational evaluation of a device developed to nondestructively assay small samples of High-Temperature Gas-Cooled Reactor (HTGR) fuel. The measurement technique employed consists in thermal-neutron irradiation of a sample followed by pneumatic transfer to a high-efficiency neutron detector where delayed neutrons are counted. In general,more » samples undergo several irradiation and count cycles during a measurement. The total number of delayed-neutron counts accumulated is translated into grams of fissile mass through comparison with the counts accumulated in an identical irradiation and count sequence of calibration standards. Successful operation of the device through many experiments over a one-year period indicates high operational reliability. Tests of assay precision show this to be better than 0.25% for measurements of 10 min. Assay biases may be encountered if calibration standards are not representative of unknown samples, but reasonable care in construction and control of standards should lead to no more than 0.2% bias in the measurements. Nondestructive fissile assay of HTGR fuel samples by thermal-neutron irradiation and delayed-neutron detection has been demonstrated to be a rapid and accurate analysis technique. However, careful attention and control must be given to calibration standards to see that they remain representative of unknown samples.« less

  11. Organic solar cells: evaluation of the stability of P3HT using time-delayed degradation

    NASA Astrophysics Data System (ADS)

    Poh, Chung-How; Poh, Chung-Kiak; Bryant, Glenn; Belcher, Warwick; Dastoor, Paul

    2011-12-01

    Despite the fact that the performance of organic solar cells is generally susceptible to degradation by moisture exposure, there has been suggestion that the photoactive layer (P3HT) is surprisingly resilient. This work attempts to confirm the stability of P3HT as an organic solar cell material by deliberately introducing water into the photoactive layer. A dramatic step drop in device performance during cell characterization is observed approximately one day after the device has been fabricated. The time-delayed step drop in output efficiency strongly suggests that moisture has little effect on the P3HT conducting polymer.

  12. Role of Structural Asymmetry in Controlling Drop Spacing in Microfluidic Ladder Networks

    NASA Astrophysics Data System (ADS)

    Wang, William; Maddala, Jeevan; Vanapalli, Siva; Rengasamy, Raghunathan

    2012-02-01

    Manipulation of drop spacing is crucial to many processes in microfluidic devices including drop coalescence, detection and storage. Microfluidic ladder networks ---where two droplet-carrying parallel channels are connected by narrow bypass channels through which the motion of drops is forbidden---have been proposed as a means to control relative separation between pairs of drops. Prior studies in microfluidic ladder networks with vertical bypasses, which possess fore-aft structural symmetry, have revealed that pairs of drops can only undergo reduction in drop spacing at the ladder exit. We investigate the dynamics of drops in microfluidic ladder networks with both vertical and slanted bypasses. Our analytical results indicate that unlike symmetric ladder networks, structural asymmetry introduced by a single slanted bypass can be used to modulate the relative spacing between drops, enabling them to contract, synchronize, expand or even flip at the ladder exit. Our experiments confirm all the behaviors predicted by theory. Numerical analysis further shows that ladders containing several identical bypasses can only linearly transform the input drop spacing. Finally, we find that ladders with specific combinations of vertical and slanted bypasses can generate non-linear transformation of input drop spacing, despite the absence of drop decision-making events at the bypass junctions.

  13. Final Technical Report- Radiation Hard Tight Pitch GaInP SPAD Arrays for High Energy Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmon, Eric S.

    The specialized photodetectors used in high energy physics experiments often need to remain extremely sensitive for years despite radiation induced damage caused by the constant bombardment of high energy particles. To solve this problem, LightSpin Technologies, Inc. in collaboration with Prof. Bradley Cox and the University of Virginia is developing radiation-hard GaInP photodetectors which are projected to be extraordinarily radiation hard, theoretically capable of withstanding a 100,000-fold higher radiation dose than silicon. In this Phase I SBIR project, LightSpin investigated the performance and radiation hardness of fifth generation GaInP SPAD arrays. These fifth generation devices used a new planar processingmore » approach that enables very tight pitch arrays to be produced. High performance devices with SPAD pitches of 11, 15, and 25 μm were successfully demonstrated, which greatly increased the dynamic range and maximum count rate of the devices. High maximum count rates are critical when considering radiation hardness, since radiation damage causes a proportional increase in the dark count rate, causing SPAD arrays with low maximum count rates (large SPAD pitches) to fail. These GaInP SPAD array Photomultiplier Chips™ were irradiated with protons, electrons, and neutrons. Initial irradiation results were disappointing, with the post-irradiation devices exhibiting excessively high dark currents. The degradation was traced to surface leakage currents that were largely eliminated through the use of trenches etched around the exterior of the Photomultiplier Chip™ (not between SPAD elements). A second round of irradiations on Photomultiplier Chips™ with trenches proved substantially more successful, with post-irradiation dark currents remaining relatively low, though dark count rates were observed to increase at the highest doses. Preliminary analysis of the post-irradiation devices is promising … many of the irradiated Photomultiplier Chips™ still exhibit good gain characteristics after 1E12/cm 2 – 1E13/cm 2 doses and have apparent dark count rates that are lower than the apparent dark count rates published for irradiation of silicon SPAD arrays (silicon photomultipliers or SiPMs). Some post-irradiation results are still pending because the samples will still too radioactive to be shipped back from the irradiation facility for post-irradiation testing.« less

  14. REACTOR CONTROL MECHANISM

    DOEpatents

    Lane, J.A.; Engberg, R.E.; Welch, J.M.

    1959-05-12

    A quick-releasing mechanism is described which may be used to rapidiy drop a device supported from beneath during normal use, such as a safety rod in a nuclear reactor. In accordance with this invention an electrical control signal, such as may be provided by radiation detection or other alarm condition sensing devices, is delivered to an electromagnetic solenoid, the armature of which is coupled to an actuating mechanism. The solenoid is energized when the mechanism is in its upper or cocked position. In such position, the mechanism engages a plurality of retaining balls, forcing them outward into engagement with a shoulder or recess in a corresponding section of a tubular extension on the upheld device. When the control signal to the solenoid suddenly ceases, the armature drops out, allowing the actuating mechanism to move slightly but rapidly under the force of a compressed spring. The weight of the device will urge the balls inward against a beveled portion of the actuating mechanism and away from the engaging section on the tubular extension, thus allowing the upheld device to fall freely under the influence of gravity.

  15. Fast selective trapping and release of picoliter droplets in a 3D microfluidic PDMS multi-trap system with bubbles.

    PubMed

    Rambach, Richard W; Biswas, Preetika; Yadav, Ashutosh; Garstecki, Piotr; Franke, Thomas

    2018-02-12

    The selective manipulation and incubation of individual picoliter drops in high-throughput droplet based microfluidic devices still remains challenging. We used a surface acoustic wave (SAW) to induce a bubble in a 3D designed multi-trap polydimethylsiloxane (PDMS) device to manipulate multiple droplets and demonstrate the selection, incubation and on-demand release of aqueous droplets from a continuous oil flow. By controlling the position of the acoustic actuation, individual droplets are addressed and selectively released from a droplet stream of 460 drops per s. A complete trapping and releasing cycle can be as short as 70 ms and has no upper limit for incubation time. We characterize the fluidic function of the hybrid device in terms of electric power, pulse duration and acoustic path.

  16. Implementing MANETS in Android based environment using Wi-Fi direct

    NASA Astrophysics Data System (ADS)

    Waqas, Muhammad; Babar, Mohammad Inayatullah Khan; Zafar, Mohammad Haseeb

    2015-05-01

    Packet loss occurs in real-time voice transmission over wireless broadcast Ad-hoc network which creates disruptions in sound. Basic objective of this research is to design a wireless Ad-hoc network based on two Android devices by using the Wireless Fidelity (WIFI) Direct Application Programming Interface (API) and apply the Network Codec, Reed Solomon Code. The network codec is used to encode the data of a music wav file and recover the lost packets if any, packets are dropped using a loss module at the transmitter device to analyze the performance with the objective of retrieving the original file at the receiver device using the network codec. This resulted in faster transmission of the files despite dropped packets. In the end both files had the original formatted music files with complete performance analysis based on the transmission delay.

  17. RESULTS OF YEAR-LONG RADIOPHOSPHORUS ADMINISTRATION IN POLYCYTHEMIA VERA (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stecher, G.

    1961-10-01

    The results of treating 140 cases of polycythemia vera with P/sup 32/ over the last 9 yr are described. Oral doses of 4 to 5 mc P/sup 32/ or intravenous doses of 3 to 8 mc were given. Two-thirds of the patients experienced remission of the disease after the 1st P/sup 32/ dose, the remissions lasting 8 months or longer. The remainder of the patients required a 2nd dose. The average duration of remission was 20 months with over haif exceeding 1 yr. The mean dose to obtain remission was 4.4 mc/yr. The required dose was directly related to themore » degree of splenomegaly, leukocytosis, and duration of the disease. The higher the initial circulating erythrocyte count before P/sup 32/ treatment, the greater the drop after treatment. The average drop in erythrocyte count was 1.8, 2.4, and 2.6 x 10/sup 6/ after P/sup 32/ doses of 3-5, 5-7, and 7 mc, respectively. In cases with initial counts of 7.5 x 10/sup 6//cu mm the respective decrements in the counts were resulted in transitory anemia, leukopenia, or thrombopenia. Five patients died of leukemia but the infiuence of the P/sup 32/ dose, if any, on this complication could not be determined. Twenty other patients died from the complications of polycythemia, such as thrombosis and hemorrhage. The recommended single dose is 4-5 mc P/sup 32/, which should be repeated after 3 to 4 months if there is an inadequate response to the 1st dose. (H.H.D.)« less

  18. Analysis of Platelet-Rich Plasma Extraction

    PubMed Central

    Fitzpatrick, Jane; Bulsara, Max K.; McCrory, Paul Robert; Richardson, Martin D.; Zheng, Ming Hao

    2017-01-01

    Background: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. Purpose: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. Study Design: Controlled laboratory study. Methods: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. Results: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. Conclusion: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. Clinical Relevance: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. PMID:28210651

  19. Shared performance monitor in a multiprocessor system

    DOEpatents

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  20. Initial steps toward the realization of large area arrays of single photon counting pixels based on polycrystalline silicon TFTs

    NASA Astrophysics Data System (ADS)

    Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua; Jiang, Hao; Street, Robert A.; Lu, Jeng Ping

    2014-03-01

    The thin-film semiconductor processing methods that enabled creation of inexpensive liquid crystal displays based on amorphous silicon transistors for cell phones and televisions, as well as desktop, laptop and mobile computers, also facilitated the development of devices that have become ubiquitous in medical x-ray imaging environments. These devices, called active matrix flat-panel imagers (AMFPIs), measure the integrated signal generated by incident X rays and offer detection areas as large as ~43×43 cm2. In recent years, there has been growing interest in medical x-ray imagers that record information from X ray photons on an individual basis. However, such photon counting devices have generally been based on crystalline silicon, a material not inherently suited to the cost-effective manufacture of monolithic devices of a size comparable to that of AMFPIs. Motivated by these considerations, we have developed an initial set of small area prototype arrays using thin-film processing methods and polycrystalline silicon transistors. These prototypes were developed in the spirit of exploring the possibility of creating large area arrays offering single photon counting capabilities and, to our knowledge, are the first photon counting arrays fabricated using thin film techniques. In this paper, the architecture of the prototype pixels is presented and considerations that influenced the design of the pixel circuits, including amplifier noise, TFT performance variations, and minimum feature size, are discussed.

  1. How merging droplets jump off a superhydrophobic surface: Measurements and model

    NASA Astrophysics Data System (ADS)

    Mouterde, Timothée; Nguyen, Thanh-Vinh; Takahashi, Hidetoshi; Clanet, Christophe; Shimoyama, Isao; Quéré, David

    2017-11-01

    We investigate how drops merging on a nonwettable surface jump off this surface, for both symmetric and asymmetric coalescences. For this purpose, we design and build a microelectromechanical system sensor able to quantify forces down to the micro-Newton scale at a high acquisition rate (200 kHz). Using this device, we perform direct force measurements of self-propelled droplets coupled to high-speed imaging. Experimental data show that the total momentum of the drop after coalescence mainly depends on the size of the smaller drop. Exploiting this finding, we quantitatively predict the takeoff speed of jumping drop pairs and show how to correct the usual argument based on energy conservation.

  2. Spectroscopic micro-tomography of metallic-organic composites by means of photon-counting detectors

    NASA Astrophysics Data System (ADS)

    Pichotka, M.; Jakubek, J.; Vavrik, D.

    2015-12-01

    The presumed capabilities of photon counting detectors have aroused major expectations in several fields of research. In the field of nuclear imaging ample benefits over standard detectors are to be expected from photon counting devices. First of all a very high contrast, as has by now been verified in numerous experiments. The spectroscopic capabilities of photon counting detectors further allow material decomposition in computed tomography and therefore inherently adequate beam hardening correction. For these reasons measurement setups featuring standard X-ray tubes combined with photon counting detectors constitute a possible replacement of the much more cost intensive tomographic setups at synchrotron light-sources. The actual application of photon counting detectors in radiographic setups in recent years has been impeded by a number of practical issues, above all by restrictions in the detectors size. Currently two tomographic setups in Czech Republic feature photon counting large-area detectors (LAD) fabricated in Prague. The employed large area hybrid pixel-detector assemblies [1] consisting of 10×10/10×5 Timepix devices have a surface area of 143×143 mm2 / 143×71,5 mm2 respectively, suitable for micro-tomographic applications. In the near future LAD devices featuring the Medipix3 readout chip as well as heavy sensors (CdTe, GaAs) will become available. Data analysis is obtained by a number of in house software tools including iterative multi-energy volume reconstruction.In this paper tomographic analysis of of metallic-organic composites is employed to illustrate the capabilities of our technology. Other than successful material decomposition by spectroscopic tomography we present a method to suppress metal artefacts under certain conditions.

  3. Dielectrophoretic columnar focusing device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D; Galambos, Paul C; Derzon, Mark S

    2010-05-11

    A dielectrophoretic columnar focusing device uses interdigitated microelectrodes to provide a spatially non-uniform electric field in a fluid that generates a dipole within particles in the fluid. The electric field causes the particles to either be attracted to or repelled from regions where the electric field gradient is large, depending on whether the particles are more or less polarizable than the fluid. The particles can thereby be forced into well defined stable paths along the interdigitated microelectrodes. The device can be used for flow cytometry, particle control, and other process applications, including cell counting or other types of particle counting,more » and for separations in material control.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madanian, H.; Cravens, T. E.; Burch, J.

    The plasma environment near comet 67P/Churyumov–Gerasimenko (67P/CG) is dynamically affected by various factors, including the incident solar wind and outgassing from the nucleus. The Rosetta spacecraft MAGnetometer (MAG) instrument observations near perihelion showed crossing events into a magnetic field-free region at about 170 km from the nucleus in 2015 July at 1.26 au from the Sun. At each crossing, the magnitude of the magnetic field dropped by more than 20 nT to near zero. We compared the Ion and Electron Sensor (IES) electron differential flux energy spectrum inside and outside the crossing boundaries. The IES observations show a modest butmore » consistent drop in electron flux for energies between 40 eV and a few hundred eV at each cavity crossing event. This drop in the electron spectra might be due to the absence or attenuation of solar wind electrons inside the observed diamagnetic regions, which might or might not be a diamagnetic cavity. There is no apparent simple linear correlation between the electron count rate measured by the IES at different energies and the magnitude of the magnetic field, however; at all energies, the highest electron count rates are recorded at the highest magnetic field magnitudes. From model-data comparisons it seems that inside diamagnetic regions, pure coma photoelectrons are not sufficient to explain the observations and that a trapping mechanism and/or infused solar wind electrons are necessary to explain the observed electron fluxes.« less

  5. An Egg-Centric Approach to Teaching Strategic Types: Adapting a Classic Exercise

    ERIC Educational Resources Information Center

    Warner, Alfred G.

    2005-01-01

    This article introduces a variation on the egg-drop exercise to generate active understanding of strategic choice by firms. Teams are challenged to design, build, and price devices for protecting an egg from a 20-foot drop. The materials are purchased in a bidding process that builds in asymmetries in resources, costs, and finished designs. Teams…

  6. Two months of disdrometer data in the Paris area

    NASA Astrophysics Data System (ADS)

    Gires, Auguste; Tchiguirinskaia, Ioulia; Schertzer, Daniel

    2018-05-01

    The Hydrology, Meteorology, and Complexity laboratory of École des Ponts ParisTech (hmco.enpc.fr) has made a data set of optical disdrometer measurements available that come from a campaign involving three collocated devices from two different manufacturers, relying on different underlying technologies (one Campbell Scientific PWS100 and two OTT Parsivel2 instruments). The campaign took place in January-February 2016 in the Paris area (France). Disdrometers provide access to information on the size and velocity of drops falling through the sampling area of the devices of roughly a few tens of cm2. It enables the drop size distribution to be estimated and rainfall microphysics, kinetic energy, or radar quantities, for example, to be studied further. Raw data, i.e. basically a matrix containing a number of drops according to classes of size and velocity, along with more aggregated ones, such as the rain rate or drop size distribution with filtering, are available. Link to the data set: https://zenodo.org/record/1240168 (DOI: https://doi.org/10.5281/zenodo.1240168).

  7. A steady state pressure drop model for screen channel liquid acquisition devices

    NASA Astrophysics Data System (ADS)

    Hartwig, J. W.; Darr, S. R.; McQuillen, J. B.; Rame, E.; Chato, D. J.

    2014-11-01

    This paper presents the derivation of a simplified one dimensional (1D) steady state pressure drop model for flow through a porous liquid acquisition device (LAD) inside a cryogenic propellant tank. Experimental data is also presented from cryogenic LAD tests in liquid hydrogen (LH2) and liquid oxygen (LOX) to compare against the simplified model and to validate the model at cryogenic temperatures. The purpose of the experiments was to identify the various pressure drop contributions in the analytical model which govern LAD channel behavior during dynamic, steady state outflow. LH2 pipe flow of LAD screen samples measured the second order flow-through-screen (FTS) pressure drop, horizontal LOX LAD outflow tests determined the relative magnitude of the third order frictional and dynamic losses within the channel, while LH2 inverted vertical outflow tests determined the magnitude of the first order hydrostatic pressure loss and validity of the full 1D model. When compared to room temperature predictions, the FTS pressure drop is shown to be temperature dependent, with a significant increase in flow resistance at LH2 temperatures. Model predictions of frictional and dynamic losses down the channel compare qualitatively with LOX LADs data. Meanwhile, the 1D model predicted breakdown points track the trends in the LH2 inverted outflow experimental results, with discrepancies being due to a non-uniform injection velocity across the LAD screen not accounted for in the model.

  8. Large-scale femtoliter droplet array for digital counting of single biomolecules.

    PubMed

    Kim, Soo Hyeon; Iwai, Shino; Araki, Suguru; Sakakihara, Shouichi; Iino, Ryota; Noji, Hiroyuki

    2012-12-07

    We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a conventional micropipette, this is achieved by sequential injection first with an aqueous solution containing beads, and then with fluorinated oil. The concentration of target biomolecules is estimated from the ratio of the number of signal-emitting droplets to the total number of trapped beads (digital counting). The performance of our digital counting device was demonstrated by detecting a streptavidin-β-galactosidase conjugate with a limit of detection (LOD) of 10 zM. The sensitivity of our device was >20-fold higher than that noted in previous studies where a smaller number of reactors (fifty thousand reactors) were used. Such a low LOD was achieved because of the large number of droplets in an array, allowing simultaneous examination of a large number of beads. When combined with bead-based enzyme-linked immunosorbent assay (digital ELISA), the LOD for the detection of prostate specific antigen reached 2 aM. This value, again, was improved over that noted in a previous study, because of the decreased coefficient of variance of the background measurement determined by the Poisson noise. Our digital counting device using one million droplets has great potential as a highly sensitive, portable immunoassay device that could be used to diagnose diseases.

  9. Mobile Device Accuracy for Step Counting Across Age Groups.

    PubMed

    Modave, François; Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W

    2017-06-28

    Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly undercounted steps for the group ranging from 65-84 years. Our analysis shows that apart from the Fitbit Surge, most of the recent mobile devices we tested do not overcount or undercount steps in the 18-39-year-old age group, however some devices undercount steps in older age groups. This finding suggests that accuracy in step counting may be an issue with some popular wearable devices, and that age may be a factor in undercounting. These results are particularly important for clinical interventions using such devices and other activity trackers, in particular to balance energy requirements with energy expenditure in the context of a weight loss intervention program. ©François Modave, Yi Guo, Jiang Bian, Matthew J Gurka, Alice Parish, Megan D Smith, Alexandra M Lee, Thomas W Buford. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 28.06.2017.

  10. The physical properties of generic latanoprost ophthalmic solutions are not identical.

    PubMed

    Kolko, Miriam; Koch Jensen, Peter

    2017-06-01

    To compare various characteristics of Xalatan ® and five generic latanoprost ophthalmic solutions. Drop size, volume, pH values, buffer capacity, viscosity, hardness of bottles and costs were determined. Drop sizes were measured in triplicates by micropipettes, and the number of drops counted in three separate bottles of each generic product was determined. pH values were measured in triplicates by a calibrated pH meter. Buffer capacity was exploited by titrating known quantities of strong base into 2.5 ml of each brand and interpolated to neutral pH. Kinematic viscosity was determined by linear regression of timed gravity flow from a vertical syringe through a 21-G cannula. The hardness of the bottles was evaluated by gradually increasing tension on a hook placed around each bottle until a drop was expelled reading the tension on an attached spring scale. Drop sizes and the number of drops in the bottles varied significantly between the generic drugs. The control value of pH in the brand version (Xalatan ® ) was markedly lower compared to the generic latanoprost products. Titration of Xalatan ® to neutrality required substantially more NaOH compared to the generic latanoprost products. Finally, the viscosity revealed a significant variability between brands. Remarkable differences were found in bottle shapes, bottle hardness and costs of the latanoprost generics. Generic latanoprost eye drops should not be considered identical to the original brand version as regards to drop size, volumes, pH values, buffer capacity, viscosity, hardness of bottles and costs. It is likely that these issues affect compliance and intraocular pressure (IOP)-lowering effect. Therefore, re-evaluation of the requirements for introducing generic eye drops seems reasonable. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    NASA Astrophysics Data System (ADS)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  12. Death of the Escherichia coli K-12 strain W3110 in soil and water.

    PubMed Central

    Bogosian, G; Sammons, L E; Morris, P J; O'Neil, J P; Heitkamp, M A; Weber, D B

    1996-01-01

    Whether Escherichia coli K-12 strain W3110 can enter the "viable but nonculturable" state was studied with sterile and nonsterile water and soil at various temperatures. In nonsterile river water, the plate counts of added E. coli cells dropped to less than 10 CFU/ml in less than 10 days. Acridine orange direct counts, direct viable counts, most-probable-number estimates, and PCR analyses indicated that the added E. coli cells were disappearing from the water in parallel with the number of CFU. Similar results were obtained with nonsterile soil, although the decline of the added E. coli was slower. In sterile water or soil, the added E. coli persisted for much longer, often without any decline in the plate counts even after 50 days. In sterile river water at 37 degrees C and sterile artificial seawater at 20 and 37 degrees C, the plate counts declined by 3 to 5 orders of magnitude, while the acridine orange direct counts remained unchanged. However, direct viable counts and various resuscitation studies all indicated that the nonculturable cells were nonviable. Thus, in either sterile or nonsterile water and soil, the decline in plate counts of E. coli K-12 strain W3110 is not due to the cells entering the viable but nonculturable state, but is simply due to their death. PMID:8900002

  13. A novel method of personnel cooling in an operating theatre environment.

    PubMed

    Casha, Aaron R; Manché, Alexander; Camilleri, Liberato; Gauci, Marilyn; Grima, Joseph N; Borg, Michael A

    2014-10-01

    An optimized theatre environment, including personal temperature regulation, can help maintain concentration, extend work times and may improve surgical outcomes. However, devices, such as cooling vests, are bulky and may impair the surgeon's mobility. We describe the use of a low-cost, low-energy 'bladeless fan' as a personal cooling device. The safety profile of this device was investigated by testing air quality using 0.5- and 5-µm particle counts as well as airborne bacterial counts on an operating table simulating a wound in a thoracic operation in a busy theatre environment. Particle and bacterial counts were obtained with both an empty and full theatre, with and without the 'bladeless fan'. The use of the 'bladeless fan' within the operating theatre during the simulated operation led to a minor, not statistically significant, lowering of both the particle and bacterial counts. In conclusion, the 'bladeless fan' is a safe, effective, low-cost and low-energy consumption solution for personnel cooling in a theatre environment that maintains the clean room conditions of the operating theatre. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Electrochemical device

    DOEpatents

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  15. Reducing the Teen Birth Rate. KIDS COUNT Indicator Brief

    ERIC Educational Resources Information Center

    Shore, Rima; Shore, Barbara

    2009-01-01

    Teen childbearing affects young people at both ends of childhood. When teens have children, their own health may be jeopardized and their chances to build productive lives are often diminished. Compared to women who postpone childbearing until they are older, teenage mothers are more likely to drop out of school and to live in poverty. At the same…

  16. Opportunity Cost: A Reply

    ERIC Educational Resources Information Center

    Parkin, Michael

    2016-01-01

    The author's objective for this reply in reexamining opportunity cost was to draw attention to two conflicting definitions of the concept in current use and to argue the case for dropping one of them. The comments of Daniel Arce, Rod O'Donnell, and Daniel Stone might be read as demonstration that the author has failed on both counts. Such a…

  17. Structural tests using a MEMS acoustic emission sensor

    NASA Astrophysics Data System (ADS)

    Oppenheim, Irving J.; Greve, David W.; Ozevin, Didem; Hay, D. Robert; Hay, Thomas R.; Pessiki, Stephen P.; Tyson, Nathan L.

    2006-03-01

    In a collaborative project at Lehigh and Carnegie Mellon, a MEMS acoustic emission sensor was designed and fabricated as a suite of six resonant-type capacitive transducers in the frequency range between 100 and 500 kHz. Characterization studies showed good comparisons between predicted and experimental electro-mechanical behavior. Acoustic emission events, simulated experimentally in steel ball impact and in pencil lead break tests, were detected and source localization was demonstrated. In this paper we describe the application of the MEMS device in structural testing, both in laboratory and in field applications. We discuss our findings regarding housing and mounting (acoustic coupling) of the MEMS device with its supporting electronics, and we then report the results of structural testing. In all tests, the MEMS transducers were used in parallel with commercial acoustic emission sensors, which thereby serve as a benchmark and permit a direct observation of MEMS device functionality. All tests involved steel structures, with particular interest in propagation of existing cracks or flaws. A series of four laboratory tests were performed on beam specimens fabricated from two segments (Grade 50 steel) with a full penetration weld (E70T-4 electrode material) at midspan. That weld region was notched, an initial fatigue crack was induced, and the specimens were then instrumented with one commercial transducer and with one MEMS device; data was recorded from five individual transducers on the MEMS device. Under a four-point bending test, the beam displayed both inelastic behavior and crack propagation, including load drops associated with crack instability. The MEMS transducers detected all instability events as well as many or most of the acoustic emissions occurring during plasticity and stable crack growth. The MEMS transducers were less sensitive than the commercial transducer, and did not detect as many events, but the normalized cumulative burst count obtained from the MEMS transducers paralleled the count obtained from the commercial transducer. Waveform analysis of signals from the MEMS transducers provided additional information concerning arrivals of P-waves and S-waves. Similarly, the analysis provided additional confirmation that the acoustic emissions emanated from the damage zone near the crack tip, and were not spurious signals or artifacts. Subsequent tests were conducted in a field application where the MEMS transducers were redundant to a group of commercial transducers. The application example is a connection plate in truss bridge construction under passage of heavy traffic loads. The MEMS transducers were found to be functional, but were less sensitive in their present form than existing commercial transducers. We conclude that the transducers are usable in their current configuration and we outline applications for which they are presently suited, and then we discuss alternate MEMS structures that would provide greater sensitivity.

  18. dropEst: pipeline for accurate estimation of molecular counts in droplet-based single-cell RNA-seq experiments.

    PubMed

    Petukhov, Viktor; Guo, Jimin; Baryawno, Ninib; Severe, Nicolas; Scadden, David T; Samsonova, Maria G; Kharchenko, Peter V

    2018-06-19

    Recent single-cell RNA-seq protocols based on droplet microfluidics use massively multiplexed barcoding to enable simultaneous measurements of transcriptomes for thousands of individual cells. The increasing complexity of such data creates challenges for subsequent computational processing and troubleshooting of these experiments, with few software options currently available. Here, we describe a flexible pipeline for processing droplet-based transcriptome data that implements barcode corrections, classification of cell quality, and diagnostic information about the droplet libraries. We introduce advanced methods for correcting composition bias and sequencing errors affecting cellular and molecular barcodes to provide more accurate estimates of molecular counts in individual cells.

  19. Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion

    PubMed Central

    Kim, Minjeong; Park, Jisun

    2018-01-01

    Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/µL to 2000/µL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. PMID:29214792

  20. Small, Fast TES Microcalorimeters with Unprecedented X-ray Spectral Performance

    NASA Technical Reports Server (NTRS)

    Eckart, M. E.; Adams, J. S.; Bailey, C. N.; Bandler, S. R.; Chervenak, J. A.; Finkbeiner, F. M.; Kelley, R. L.; Kilbourne, C. A.; Porter, F. S.; Sadleir, J. E.; hide

    2011-01-01

    Driven initially by the desire for X-ray microcalorimeter arrays suitable for imaging the dynamic solar corona, we have developed a transition-edge-sensor (TES) microcalorimeter optimization that exhibits a unique combination of high spectral resolving power and a wide X-ray bandpass. These devices have achieved spectral performance of dE approximately 1.3 eV FWHM at 1.5 keV, 1.6 eV at 6 keV, and 2.0 eV at 8 keV, using small TESs (e.g., approximately 35 micron x 35 micron) that operate in a regime in which the superconducting transition is highly current dependent. In order to accommodate high X-ray count rates, the devices sit directly on a solid substrate instead of on membranes, and we use an embedded heatsinking layer to reduce pixel-to-pixel crosstalk. We will present results from devices with a range of TES and absorber sizes, and from device wafers with varied embedded heatsink materials. This contribution will focus on count-rate capabilities, including a discussion of the trade-off between count rate and energy resolution, and the heatsinking design. We will also present preliminary tests of array readout using a code-division multiplexed SQUID readout scheme, which may be necessary to enable large arrays of these fast devices.

  1. On Line Digitizer Software.

    DTIC Science & Technology

    1984-06-01

    UNSOLINTERRUPT: ; Dismiss unsolicited Interrupt. POPR M<RI,RI,R2,R3,R4,R5> ; Restore RZ-R5 REI ; Return from interrupt. .SBTTL AVCANCEL. Cancel I/O routine...Dismiss unsolicited Interrupt. POPR M<R8,RI.R2,R3,R4,R5> ; Restore RN-R5 REI ; Return from interrupt. .SBTTL ODCANCEL, Cancel I/0 routine ++ I ODCANCEL...output buffer. ODREGDU4P: i Dump device registers MOVZBL ODNUMREGS,(Rg)+ i Store device register count. NOVZWL UCBSWODBYTCNT(RS),- aStore BYTE count

  2. Add/drop filters based on SiC technology for optical interconnects

    NASA Astrophysics Data System (ADS)

    Vieira, M.; Vieira, M. A.; Louro, P.; Fantoni, A.; Silva, V.

    2014-03-01

    In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.

  3. Design study of an advanced gas generator. [which can be ignited during start-up period of turbine engines

    NASA Technical Reports Server (NTRS)

    Kim, S.; Trinh, H. P.

    1993-01-01

    A gas generator which can be ignited reliably during the initial start-up period and offers fairly uniform gas temperature at the exit was studied numerically. Various sizes and shapes of the mixing enhancement devices and their positions were examined to evaluate the uniformity of the exit gas temperature and the change of internal pressure drop incurred by introducing the mixing enhancement devices. By introducing a turbulence ring and a splash plate with an appropriate size and position, it was possible to obtain fairly uniform gas temperature distributions and a maximum gas temperature that is within the design limit temperature of 1600 R at the generator exit. However, with the geometry studied, the pressure drop across the generator was great, approximately 1150 psi, to satisfy the assigned design limit temperature. If the design limit temperature is increased to 1650 R, the pressure drop across the generator could be lowered by as much as 350 psi.

  4. Mechanism and Design Analysis of Articulated Ankle Foot Orthoses for Drop-Foot

    PubMed Central

    Choudhury, Imtiaz Ahmed; Mamat, Azuddin Bin

    2014-01-01

    Robotic technologies are being employed increasingly in the treatment of lower limb disabilities. Individuals suffering from stroke and other neurological disorders often experience inadequate dorsiflexion during swing phase of the gait cycle due to dorsiflexor muscle weakness. This type of pathological gait, mostly known as drop-foot gait, has two major complications, foot-slap during loading response and toe-drag during swing. Ankle foot orthotic (AFO) devices are mostly prescribed to resolve these complications. Existing AFOs are designed with or without articulated joint with various motion control elements like springs, dampers, four-bar mechanism, series elastic actuator, and so forth. This paper examines various AFO designs for drop-foot, discusses the mechanism, and identifies limitations and remaining design challenges. Along with two commercially available AFOs some designs possess promising prospective to be used as daily-wear device. However, the design and mechanism of AFO must ensure compactness, light weight, low noise, and high efficiency. These entailments present significant engineering challenges to develop a new design with wide consumer adoption. PMID:24892102

  5. Exciting New Take on a Classic: Crash Testing Activity Puts the Egg in the Driver's Seat

    ERIC Educational Resources Information Center

    Board, Keith

    2011-01-01

    An excellent common activity in technology and engineering classes involves dropping an egg from a significant height in a protective device designed and built by students. This article describes how the author uses the classic "egg drop" as an inspiration to have students modify a small crash test vehicle that speeds down a track and crashes into…

  6. Exciting New Take on a Classic: Crash Test Activity Puts the Egg in the Driver's Seat

    ERIC Educational Resources Information Center

    Board, Keith

    2011-01-01

    An excellent common activity in technology and engineering classes involves dropping an egg from a significant height in a protective device designed and built by students. This article describes how the author uses the classic "egg drop" as an inspiration to have students modify a small crash test vehicle that speeds down a track and crashes into…

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Keyu; Shenzhen Key Laboratory of Micro-Nano Photonic Information Technology, Shenzhen 518067; College of Electronic Science and Technology, Shenzhen University, Shenzhen 518067

    We present a versatile add-drop integrated photonic filter (ADF) consisting of nonreciprocal waveguides in which the propagation of light is restricted in one predetermined direction. With the bus and add/drop waveguides symmetrically coupled through a cavity, the four-port device allows each individual port to add and/or drop a signal of the same frequency. The scheme is general and we demonstrate the nonreciprocal ADF with magneto-optical photonic crystals. The filter is immune to waveguide defects, allowing straightforward implementation of multi-channel ADFs by cascading the four-port designs. The results should find applications in wavelength-division multiplexing and related integrated photonic techniques.

  8. Tunable all-optical photonic crystal channel drop filter for DWDM systems

    NASA Astrophysics Data System (ADS)

    Habibiyan, H.; Ghafoori-Fard, H.; Rostami, A.

    2009-06-01

    In this paper we propose a tunable channel drop filter in a two-dimensional photonic crystal, based on coupled-cavity waveguides with alternating small and large defects and an electromagnetically induced transparency phenomenon. By utilizing this phenomenon a narrower linewidth is obtained and also the frequency of the dropped signal becomes tunable. Simulation results show that the proposed filter is suitable for dense wavelength-division multiplexing (DWDM) systems with 0.8 nm channel spacing. Using this novel component, two ultrasmall eight-channel double-sided and single-sided demultiplexers are introduced. The properties of these devices are investigated using the finite-difference time-domain method. For the single-sided device, transmission loss is 1.5 ± 0.5 dB, the cross-talk level between adjacent channels is better than -18 dB and the average 3 dB optical passband is 0.36 nm. Using planar silicon-on-insulator technology, the physical area for the single-sided component is 700 µm2 and for the double-sided component is 575 µm2. To the best of our knowledge, these are the smallest all-optical demultiplexers with this spectral resolution reported to date. Malfunction of the proposed device due to fabrication errors is modeled and its tunable characteristic is demonstrated.

  9. Investigation of 2D photonic crystal structure based channel drop filter using quad shaped photonic crystal ring resonator for CWDM system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chhipa, Mayur Kumar, E-mail: mayurchhipa1@gmail.com; Dusad, Lalit Kumar; Rajasthan Technical University, Kota, Rajasthan

    In this paper, the design & performance of two dimensional (2-D) photonic crystal structure based channel drop filter is investigated using quad shaped photonic crystal ring resonator. In this paper, Photonic Crystal (PhC) based on square lattice periodic arrays of Gallium Indium Phosphide (GaInP) rods in air structure have been investigated using Finite Difference Time Domain (FDTD) method and photonic band gap is being calculated using Plane Wave Expansion (PWE) method. The PhC designs have been optimized for telecommunication wavelength λ= 1571 nm by varying the rods lattice constant. The number of rods in Z and X directions is 21 andmore » 20, with lattice constant 0.540 nm it illustrates that the arrangement of Gallium Indium Phosphide (GaInP) rods in the structure which gives the overall size of the device around 11.4 µm × 10.8 µm. The designed filter gives good dropping efficiency using 3.298, refractive index. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.« less

  10. Point-of-care blood eosinophil count in a severe asthma clinic setting.

    PubMed

    Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio

    2017-07-01

    One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2  = 0.854, P < .001); similar correlations were found also for white blood cells, neutrophils, and lymphocytes. The point-of-care device had the ability to predict blood eosinophil cutoffs used to select patients for biologic treatments for severe eosinophilic asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  11. Accuracy of piezoelectric pedometer and accelerometer step counts.

    PubMed

    Cruz, Joana; Brooks, Dina; Marques, Alda

    2017-04-01

    This study aimed to assess step-count accuracy of a piezoeletric pedometer (Yamax PW/EX-510), when worn at different body parts, and a triaxial accelerometer (GT3X+), and to compare device accuracy; and identify the preferred location(s) to wear a pedometer. Sixty-three healthy adults (45.8±20.6 years old) wore 7 pedometers (neck, lateral right and left of the waist, front right and left of the waist, front pockets of the trousers) and 1 accelerometer (over the right hip), while walking 120 m at slow, self-preferred/normal and fast paces. Steps were recorded. Participants identified their preferred location(s) to wear the pedometer. Absolute percent error (APE) and Bland and Altman (BA) method were used to assess device accuracy (criterion measure: manual counts) and BA method for device comparisons. Pedometer APE was below 3% at normal and fast paces despite wearing location, but higher at slow pace (4.5-9.1%). Pedometers were more accurate at the front waist and inside the pockets. Accelerometer APE was higher than pedometer APE (P<0.05); nevertheless, limits of agreement between devices were relatively small. Preferred wearing locations were inside the front right (N.=25) and left (N.=20) pockets of the trousers. Yamax PW/EX-510 pedometers may be preferable than GT3X+ accelerometers to count steps, as they provide more accurate results. These pedometers should be worn at the front right or left positions of the waist or inside the front pockets of the trousers.

  12. Influence of clay particles on microfluidic-based preparation of hydrogel composite microsphere

    NASA Astrophysics Data System (ADS)

    Hong, Joung Sook

    2016-05-01

    For the successful fabrication of a hydrogel composite microsphere, this study aimed to investigate the influence of clay particles on microsphere formation in a microfluidic device which has flow focusing and a 4.5:1 contraction channel. A poly alginic acid solution (2.0 wt.%) with clay particles was used as the dispersed phase to generate drops in an oil medium, which then merged with drops of a CaCl2 solution for gelation. Drop generations were observed with different flow rates and particles types. When the flow rate increased, drop generation was enhanced and drop size decreased by the build-up of more favorable hydrodynamic flow conditions to detach the droplets. The addition of a small amount of particles insignificantly changed the drop generation behavior even though it reduced interfacial tension and increased the viscosity of the solution. Instead, clays particles significantly affected hydro-gelation depending on the hydrophobicity of particles, which produced further heterogeneity in the shape and size of microsphere.

  13. Distinguishing between microscale gaseous bubbles and liquid drops

    NASA Astrophysics Data System (ADS)

    Tan, Beng Hau; An, Hongjie; Chan, Chon U.; Ohl, Claus-Dieter

    2015-11-01

    In recent years, there has been strong research interest in decorating surfaces with tiny bubbles and drops due to their potential applications in reducing slippage in micro and nanofluidic devices. Both nanobubbles and nanodrops are typically nucleated by exchanging fluids over a suitable substrate. However, the nucleation experiments present many challenges, such as reproducibility and the possibility of contamination. The use of one-use plastic syringes and needle cannulas in nucleation experiments can introduce polymeric contamination. A contaminated experiment may nucleate bubbles, drops or both. Moreover, it is surprisingly difficult to distinguish between bubbles and drops under the usual atomic force microscopy or optical techniques. Here we present an experimental study comparing bubbles and oil (PDMS) drops on an atomically smooth surface (HOPG). Instead of nucleating the objects via solvent exchange, we directly introduced bubbles via electrolysis, and oil drops by injecting a dilute solution. Contrary to previous reports, we find that under careful AFM characterisation, liquid drops and gaseous bubbles respond differently to a change in imaging force, and moreover present different characteristic force curves.

  14. Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

    NASA Astrophysics Data System (ADS)

    Zhang, Guoqing; Lina, Liu

    2018-02-01

    An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.

  15. Drop Tower Experiments concerning Fluid Management under Microgravity

    NASA Astrophysics Data System (ADS)

    Gaulke, Diana; Dreyer, Michael

    2012-07-01

    Transport and positioning of liquid under microgravity is done utilizing capillary forces. Therefore, capillary transport processes have to be understood for a wide variety of space applications, ranging from propellant management in tanks of space transportation systems to eating and drinking devices for astronauts. There are two types of liquid transportation in microgravity using capillary forces. First, the driven liquid flow in open channels where the capillary forces at free surfaces ensure a gas and vapor free flow. Here it is important to know the limiting flow rate through such an open channel before the free surface collapses and gas is sucked into the channel. A number of different experiments at the drop tower Bremen, on sounding rockets and at the ISS have been conducted to analyse this phenomenon within different geometries. As result a geometry dependent theory for calculating the maximum flow rate has been found. On the other hand liquid positioning and transportation requires the capillary pressure of curved surfaces to achieve a liquid flow to a desired area. Especially for space applications the weight of structure has to be taken into account for development. For example liquid positioning in tanks can be achieved via a complicated set of structure filling the whole tank resulting in heavy devices not reasonable in space applications. Astrium developed in cooperation with ZARM a propellant management device much smaller than the tank volume and ensuring a gas and vapour free supply of propellant to the propulsion system. In the drop tower Bremen a model of this device was tested concerning different microgravity scenarios. To further decrease weight and ensure functionality within different scenarios structure elements are designed as perforated geometries. Capillary transport between perforated plates has been analyzed concerning the influence of geometrical pattern of perforations. The conducted experiments at the drop tower Bremen show the remarkable influence of perforations on the capillary transport capability.

  16. Droplet monitoring probe

    NASA Technical Reports Server (NTRS)

    Baughman, J. R.; Thys, P. C.

    1973-01-01

    A droplet monitoring system is disclosed for analysis of mixed-phase fluid flow in development of gas turbines. The system uses a probe comprising two electrical wires spaced a known distance apart and connected at one end to means for establishing a dc potential between the wires. A drop in the fluid stream momentarily contacting both wires simultaneously causes and electrical signal which is amplified, detected and counted.

  17. Counting Chickens before They Are Hatched: An Examination of Student Retention, Graduation, Attrition, and Dropout Measurement Validity in an Online Master's Environment

    ERIC Educational Resources Information Center

    Haydarov, Rustam; Moxley, Virginia; Anderson, Dawn

    2013-01-01

    This article examines definitions, rationales, and calculations associated with higher education performance measures: persistence, retention rate, attrition rate, drop-out rate, and graduation rate. Strengths and limitations of these measures are scrutinized relative to online master's programs. Outcomes of a sample of students (N = 96) enrolled…

  18. Every Drop Counts: Students Develop Public Service Announcements on the Importance of Water Conservation

    ERIC Educational Resources Information Center

    Stokes, Nina Christiane; Hull, Mary Margaret

    2002-01-01

    In today's fast-paced, technological world, it is a constant battle for teachers to find new and exciting ways to challenge and engage their students. One success story involves a unique collaborative project that focuses on water resources and conservation in which students design public service announcements (PSAs) to be produced and aired on…

  19. 25 CFR 542.31 - What are the minimum internal control standards for drop and count for Tier B gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  20. 25 CFR 542.41 - What are the minimum internal control standards for drop and count for Tier C gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  1. 25 CFR 542.21 - What are the minimum internal control standards for drop and count for Tier A gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the...) Alternatively, a smart bucket system that electronically identifies and tracks the gaming machine number, and...

  2. 25 CFR 542.31 - What are the minimum internal control standards for drop and count for Tier B gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  3. 25 CFR 542.41 - What are the minimum internal control standards for drop and count for Tier C gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  4. 25 CFR 542.31 - What are the minimum internal control standards for drop and count for Tier B gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  5. 25 CFR 542.41 - What are the minimum internal control standards for drop and count for Tier C gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  6. 25 CFR 542.21 - What are the minimum internal control standards for drop and count for Tier A gaming operations?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the...) Alternatively, a smart bucket system that electronically identifies and tracks the gaming machine number, and...

  7. 25 CFR 542.21 - What are the minimum internal control standards for drop and count for Tier A gaming operations?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the...) Alternatively, a smart bucket system that electronically identifies and tracks the gaming machine number, and...

  8. 25 CFR 542.21 - What are the minimum internal control standards for drop and count for Tier A gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the...) Alternatively, a smart bucket system that electronically identifies and tracks the gaming machine number, and...

  9. 25 CFR 542.41 - What are the minimum internal control standards for drop and count for Tier C gaming operations?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  10. 25 CFR 542.31 - What are the minimum internal control standards for drop and count for Tier B gaming operations?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Alternatively, it may be adequately secured (e.g., locked container to which only accounting personnel can gain... secured (e.g., locked container to which only accounting personnel can gain access) until retrieved by the... identifies and tracks the gaming machine number, and facilitates the proper recognition of gaming revenue...

  11. Dengue hemorrhagic fever and severe thrombocytopenia in a patient on mandatory anticoagulation: balancing two life threatening conditions: a case report.

    PubMed

    Gamakaranage, Champika; Rodrigo, Chaturaka; Samarawickrama, Sincy; Wijayaratne, Dilushi; Jayawardane, Malaka; Karunanayake, Panduka; Jayasinghe, Saroj

    2012-10-26

    Managing a severe dengue infection is a challenge specially when complicated by other comorbidities. We report a patient with dengue haemorrhagic fever and spontaneous bleeding who required mandatory anticoagulation for a prosthetic mitral valve replacement. This is the first case report in published literature describing this therapeutic dilemma. A fifty one year old Sri Lankan woman was diagnosed with dengue haemorrhagic fever with bleeding manifestations. During the critical phase of her illness, the platelet count dropped to 5,000/ɥl. She was also on warfarin 7 mg daily following a prosthetic mitral valve insertion. In managing the patient, the risk of bleeding had to be balanced against the risk of valve thrombosis without anticoagulation. Warfarin was withheld when the platelet count dropped to 100,000/ɥl and restarted when it recovered above 50,000/ɥl. The patient was off anticoagulation for 10 days. We managed this patient with close observation and continuous risk benefit assessments of management decisions. However, experience with one patient cannot be generalized to others. Therefore, it is essential that clinicians share their experiences in managing such difficult patients.

  12. Ultrafast Power Processor for Smart Grid Power Module Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MAITRA, ARINDAM; LITWIN, RAY; lai, Jason

    This project’s goal was to increase the switching speed and decrease the losses of the power semiconductor devices and power switch modules necessary to enable Smart Grid energy flow and control equipment such as the Ultra-Fast Power Processor. The primary focus of this project involves exploiting the new silicon-based Super-GTO (SGTO) technology and build on prototype modules already being developed. The prototype super gate-turn-off thyristor (SGTO) has been tested fully under continuously conducting and double-pulse hard-switching conditions for conduction and switching characteristics evaluation. The conduction voltage drop measurement results indicate that SGTO has excellent conduction characteristics despite inconsistency among somemore » prototype devices. Tests were conducted with two conditions: (1) fixed gate voltage and varying anode current condition, and (2) fixed anode current and varying gate voltage condition. The conduction voltage drop is relatively a constant under different gate voltage condition. In terms of voltage drop as a function of the load current, there is a fixed voltage drop about 0.5V under zero current condition, and then the voltage drop is linearly increased with the current. For a 5-kV voltage blocking device that may operate under 2.5-kV condition, the projected voltage drop is less than 2.5 V under 50-A condition, or 0.1%. If the device is adopted in a converter operating under soft-switching condition, then the converter can achieve an ultrahigh efficiency, typically above 99%. The two-pulse switching test results indicate that SGTO switching speed is very fast. The switching loss is relatively low as compared to that of the insulated-gate-bipolar-transistors (IGBTs). A special phenomenon needs to be noted is such a fast switching speed for the high-voltage switching tends to create an unexpected Cdv/dt current, which reduces the turn-on loss because the dv/dt is negative and increases the turn-off loss because the dv/dt is positive. As a result, the turn-on loss at low current is quite low, and the turn-off loss at low current is relatively high. The phenomenon was verified with junction capacitance measurement along with the dv/dt calculation. Under 2-kV test condition, the turn-on and turn-off losses at 25-A is about 3 and 9 mJ, respectively. As compared to a 4.5-kV, 60-A rated IGBT, which has turn-on and turn-off losses about 25 and 20 mJ under similar test condition, the SGTO shows significant switching loss reduction. The switching loss depends on the switching frequency, but under hard-switching condition, the SGTO is favored to the IGBT device. The only concern is during low current turn-on condition, there is a voltage bump that can translate to significant power loss and associated heat. The reason for such a current bump is not known from this study. It is necessary that the device manufacturer perform though test and provide the answer so the user can properly apply SGTO in pulse-width-modulated (PWM) converter and inverter applications.« less

  13. First comparative analysis concerning the plasma platelet contamination during MNC collection.

    PubMed

    Pfeiffer, Hella; Achenbach, Susanne; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold; Strasser, Erwin F

    2017-08-01

    Monocytes can be cultured into dendritic cells with addition of autologous plasma, which is highly prone to platelet contamination due to the apheresis process. Since platelets affect the maturation process of monocytes into dendritic cells and might even lead to a diminished harvest of dendritic cells, it is very important to reduce the platelet contamination. A new collection device (Spectra Optia) was analyzed, compared to two established devices (COM.TEC, Cobe Spectra) and evaluated regarding the potential generation of source plasma. Concurrent plasma collected during leukapheresis was analyzed for residual cell contamination in a prospective study with the new Spectra Optia apheresis device (n=24) and was compared with COM.TEC and Cobe Spectra data (retrospective analysis, n=72). Donor pre-donation counts of platelets were analyzed for their predictive value of contaminating PLTs in plasma harvests. The newest apheresis device showed the lowest residual platelet count of the collected concurrent plasma (median 3.50×10 9 /l) independent of pre-donation counts. The other two devices and sets had a higher platelet contamination. The contamination of the plasma with leukocytes was very low (only 2.0% were higher than 0.5×10 9 /l). This study showed a significant reduction of platelet contamination of the concurrent plasma collected with the new Spectra Optia device. This plasma product with low residual platelets and leukocytes might also be used as plasma for fractionation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Effect of Coffea canephora aqueous extract on microbial counts in ex vivo oral biofilms: a case study.

    PubMed

    Antonio, Andréa Gonçalves; Iorio, Natália Lopes Pontes; Farah, Adriana; Netto dos Santos, Kátia Regina; Maia, Lucianne Cople

    2012-05-01

    In the present study, the ex vivo antimicrobial effect of brewed coffee was tested on oral biofilms. For this, unsweetened and sweetened (10 % sucrose) brewed light-roasted Coffea canephora at 20 % was used in biofilms formed by non-stimulated saliva from three volunteers. After 30 min contact with unsweetened and sweetened brews, the average microorganism count in the biofilms reduced by 15.2 % and 12.4 %, respectively, with no statistical difference among them. We also observed a drop of microorganisms in the biofilms after treatment with sucrose solution at 5 % compared to control (saline) and to sucrose at 1 % and 3 %. In conclusion, Coffea canephora extract reduces the microbial count in oral biofilm, and our data suggest that sucrose concentration in coffee brew can influence its antimicrobial property against the referred biofilm. Georg Thieme Verlag KG Stuttgart · New York.

  15. Exploration of maximum count rate capabilities for large-area photon counting arrays based on polycrystalline silicon thin-film transistors

    NASA Astrophysics Data System (ADS)

    Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua

    2016-03-01

    Pixelated photon counting detectors with energy discrimination capabilities are of increasing clinical interest for x-ray imaging. Such detectors, presently in clinical use for mammography and under development for breast tomosynthesis and spectral CT, usually employ in-pixel circuits based on crystalline silicon - a semiconductor material that is generally not well-suited for economic manufacture of large-area devices. One interesting alternative semiconductor is polycrystalline silicon (poly-Si), a thin-film technology capable of creating very large-area, monolithic devices. Similar to crystalline silicon, poly-Si allows implementation of the type of fast, complex, in-pixel circuitry required for photon counting - operating at processing speeds that are not possible with amorphous silicon (the material currently used for large-area, active matrix, flat-panel imagers). The pixel circuits of two-dimensional photon counting arrays are generally comprised of four stages: amplifier, comparator, clock generator and counter. The analog front-end (in particular, the amplifier) strongly influences performance and is therefore of interest to study. In this paper, the relationship between incident and output count rate of the analog front-end is explored under diagnostic imaging conditions for a promising poly-Si based design. The input to the amplifier is modeled in the time domain assuming a realistic input x-ray spectrum. Simulations of circuits based on poly-Si thin-film transistors are used to determine the resulting output count rate as a function of input count rate, energy discrimination threshold and operating conditions.

  16. Bimatoprost-Loaded Ocular Inserts as Sustained Release Drug Delivery Systems for Glaucoma Treatment: In Vitro and In Vivo Evaluation

    PubMed Central

    Franca, Juçara Ribeiro; Foureaux, Giselle; Fuscaldi, Leonardo Lima; Ribeiro, Tatiana Gomes; Rodrigues, Lívia Bomfim; Bravo, Renata; Castilho, Rachel Oliveira; Yoshida, Maria Irene; Cardoso, Valbert Nascimento; Fernandes, Simone Odília; Cronemberger, Sebastião; Ferreira, Anderson José; Faraco, André Augusto Gomes

    2014-01-01

    The purpose of the present study was to develop and assess a novel sustained-release drug delivery system of Bimatoprost (BIM). Chitosan polymeric inserts were prepared using the solvent casting method and characterized by swelling studies, infrared spectroscopy, differential scanning calorimetry, drug content, scanning electron microscopy and in vitro drug release. Biodistribution of 99mTc-BIM eye drops and 99mTc-BIM-loaded inserts, after ocular administration in Wistar rats, was accessed by ex vivo radiation counting. The inserts were evaluated for their therapeutic efficacy in glaucomatous Wistar rats. Glaucoma was induced by weekly intracameral injection of hyaluronic acid. BIM-loaded inserts (equivalent to 9.0 µg BIM) were administered once into conjunctival sac, after ocular hypertension confirmation. BIM eye drop was topically instilled in a second group of glaucomatous rats for 15 days days, while placebo inserts were administered once in a third group. An untreated glaucomatous group was used as control. Intraocular pressure (IOP) was monitored for four consecutive weeks after treatment began. At the end of the experiment, retinal ganglion cells and optic nerve head cupping were evaluated in the histological eye sections. Characterization results revealed that the drug physically interacted, but did not chemically react with the polymeric matrix. Inserts sustainedly released BIM in vitro during 8 hours. Biodistribution studies showed that the amount of 99mTc-BIM that remained in the eye was significantly lower after eye drop instillation than after chitosan insert implantation. BIM-loaded inserts lowered IOP for 4 weeks, after one application, while IOP values remained significantly high for the placebo and untreated groups. Eye drops were only effective during the daily treatment period. IOP results were reflected in RGC counting and optic nerve head cupping damage. BIM-loaded inserts provided sustained release of BIM and seem to be a promising system for glaucoma management. PMID:24788066

  17. 77 FR 9610 - Gastroenterology-Urology Devices; Reclassification of Sorbent Hemoperfusion Devices for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-17

    ..., substances. and drugs (e.g., adsorption of glucose, unspecific removal characteristics, drop in patients... Sec. 860.130 of the regulations. XIV. Environmental Impact The Agency has determined under 21 CFR 25... impact statement is required. XV. Analysis of Impacts FDA has examined the impacts of the proposed rule...

  18. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase II Accelerated Free-Fall

    DTIC Science & Technology

    2016-04-30

    support contractor , Infoscitex, conducted a series of tests to identify the performance capabilities of the Vertical Impact Device (VID). The VID is a...C. Table 3. AFD Evaluation with Red IMPAC Programmer: Data Summary Showing Means and Standard Deviations Test Cell Drop Ht . (in) Mean Peak

  19. Are There Differences Depending on the Device Used to Complete a Web Survey (PC or Smartphone) for Order-by-Click Questions?

    ERIC Educational Resources Information Center

    Revilla, Melanie

    2017-01-01

    The development of web surveys has been accompanied by the emergence of new scales, taking advantages of the visual and interactive features provided by the Internet like drop-down menus, sliders, drag-and-drop, or order-by-click scales. This article focuses on the order-by-click scales, studying the comparability of the data obtained for this…

  20. Changes in CD4 count among persons living with HIV/AIDS following Hurricane Katrina.

    PubMed

    Robinson, William T; Wendell, Deborah; Gruber, DeAnn

    2011-07-01

    To examine the effects of Hurricane Katrina on the disease progression of persons living with HIV/AIDS (PLWH/A), CD4 counts during the 18 months immediately prior and subsequent to Katrina were obtained from the Louisiana Office of Public Health. PLWH/A were determined to be either non-residents of the New Orleans area, returning evacuees or evacuees who had returned to the area within 18 months. A mixed model repeated measures ANOVA showed significant effects for race, sex, age, year of diagnosis, and mode of exposure. A significant main effect for residence was found, as well as an interaction of residence by time of CD4 count (pre-Katrina vs. post-Katrina), indicating that, while non-returning evacuees had lower overall CD4 counts, the change in CD4 counts of non-returning evacuees dropped more sharply than those of the returning PLWH/A or non-residents. While these results point to a potential need for the population of PLWH/A who continue to be affected by Katrina, they also provide important data on the effect that large-scale disasters and stressful life events may have on individuals with chronic disease.

  1. A High Resolution Scale-of-four

    DOE R&D Accomplishments Database

    Fitch, V.

    1949-08-25

    A high resolution scale-of-four has been developed to be used in conjunction with the nuclear particle detection devices in applications where the counting rate is unusually high. Specifically, it is intended to precede the commercially available medium resolution scaling circuits and so decrease the resolving time of the counting system. The circuit will function reliably on continuously recurring pulses separated by less than 0.1 microseconds. It will resolve two pulses (occurring at a moderate repetition rate) which are spaced at 0.04 microseconds. A five-volt input signal is sufficient to actuate the device.

  2. Physical activity among children: objective measurements using Fitbit One® and ActiGraph.

    PubMed

    Hamari, Lotta; Kullberg, Tiina; Ruohonen, Jukka; Heinonen, Olli J; Díaz-Rodríguez, Natalia; Lilius, Johan; Pakarinen, Anni; Myllymäki, Annukka; Leppänen, Ville; Salanterä, Sanna

    2017-04-20

    Self-quantification of health parameters is becoming more popular; thus, the validity of the devices requires assessments. The aim of this study was to evaluate the validity of Fitbit One step counts (Fitbit Inc., San Francisco, CA, USA) against Actigraph wActisleep-BT step counts (ActiGraph, LLC, Pensacola, FL, USA) for measuring habitual physical activity among children. The study was implemented as a cross-sectional experimental design in which participants carried two waist-worn activity monitors for five consecutive days. The participants were chosen with a purposive sampling from three fourth grade classes (9-10 year olds) in two comprehensive schools. Altogether, there were 34 participants in the study. From these, eight participants were excluded from the analysis due to erroneous data. Primary outcome measures for step counts were Fitbit One and Actigraph wActisleep-BT. The supporting outcome measures were based on activity diaries and initial information sheets. Classical Bland-Altman plots were used for reporting the results. The average per-participant daily difference between the step counts from the two devices was 1937. The range was [116, 5052]. Fitbit One gave higher step counts for all but the least active participant. According to a Bland-Altman plot, the hourly step counts had a relative large mean bias across participants (161 step counts). The differences were partially explained by activity intensity: higher intensity denoted higher differences, and light intensity denoted lower differences. Fitbit One step counts are comparable to Actigraph step counts in a sample of 9-10-year-old children engaged in habitual physical activity in sedentary and light physical activity intensities. However, in moderate-to-vigorous physical activity, Fitbit One gives higher step counts when compared to Actigraph.

  3. Modeling of atomization and distribution of drop-liquid fuel in unsteady swirling flows in a combustion chamber and free space

    NASA Astrophysics Data System (ADS)

    Sviridenkov, A. A.; Toktaliev, P. D.; Tretyakov, V. V.

    2018-03-01

    Numerical and experimental research of atomization and propagation of drop-liquid phase in swirling flow behind the frontal device of combustion chamber was performed. Numerical procedure was based on steady and unsteady Reynolds equations solution. It's shown that better agreement with experimental data could be obtained with unsteady approach. Fractional time step method was implemented to solve Reynolds equations. Models of primary and secondary breakup of liquid fuel jet in swirling flows are formulated and tested. Typical mean sizes of fuel droplets for base operational regime of swirling device and combustion chamber were calculated. Comparison of main features of internal swirling flow in combustion chamber with unbounded swirling flow was made.

  4. Validation of an inertial measurement unit for the measurement of jump count and height.

    PubMed

    MacDonald, Kerry; Bahr, Roald; Baltich, Jennifer; Whittaker, Jackie L; Meeuwisse, Willem H

    2017-05-01

    To validate the use of an inertial measurement unit (IMU) for the collection of total jump count and assess the validity of an IMU for the measurement of jump height against 3-D motion analysis. Cross sectional validation study. 3D motion-capture laboratory and field based settings. Thirteen elite adolescent volleyball players. Participants performed structured drills, played a 4 set volleyball match and performed twelve counter movement jumps. Jump counts from structured drills and match play were validated against visual count from recorded video. Jump height during the counter movement jumps was validated against concurrent 3-D motion-capture data. The IMU device captured more total jumps (1032) than visual inspection (977) during match play. During structured practice, device jump count sensitivity was strong (96.8%) while specificity was perfect (100%). The IMU underestimated jump height compared to 3D motion-capture with mean differences for maximal and submaximal jumps of 2.5 cm (95%CI: 1.3 to 3.8) and 4.1 cm (3.1-5.1), respectively. The IMU offers a valid measuring tool for jump count. Although the IMU underestimates maximal and submaximal jump height, our findings demonstrate its practical utility for field-based measurement of jump load. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Validation of analytical methods in GMP: the disposable Fast Read 102® device, an alternative practical approach for cell counting.

    PubMed

    Gunetti, Monica; Castiglia, Sara; Rustichelli, Deborah; Mareschi, Katia; Sanavio, Fiorella; Muraro, Michela; Signorino, Elena; Castello, Laura; Ferrero, Ivana; Fagioli, Franca

    2012-05-31

    The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests' accuracy, precision, repeatability, linearity and range. As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution).

  6. Validation of analytical methods in GMP: the disposable Fast Read 102® device, an alternative practical approach for cell counting

    PubMed Central

    2012-01-01

    Background The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests’ accuracy, precision, repeatability, linearity and range. Methods As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. Results All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Conclusions Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution). PMID:22650233

  7. Single photon detection in a waveguide-coupled Ge-on-Si lateral avalanche photodiode.

    PubMed

    Martinez, Nicholas J D; Gehl, Michael; Derose, Christopher T; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S

    2017-07-10

    We examine gated-Geiger mode operation of an integrated waveguide-coupled Ge-on-Si lateral avalanche photodiode (APD) and demonstrate single photon detection at low dark count for this mode of operation. Our integrated waveguide-coupled APD is fabricated using a selective epitaxial Ge-on-Si growth process resulting in a separate absorption and charge multiplication (SACM) design compatible with our silicon photonics platform. Single photon detection efficiency and dark count rate is measured as a function of temperature in order to understand and optimize performance characteristics in this device. We report single photon detection of 5.27% at 1310 nm and a dark count rate of 534 kHz at 80 K for a Ge-on-Si single photon avalanche diode. Dark count rate is the lowest for a Ge-on-Si single photon detector in this range of temperatures while maintaining competitive detection efficiency. A jitter of 105 ps was measured for this device.

  8. Automatic airline baggage counting using 3D image segmentation

    NASA Astrophysics Data System (ADS)

    Yin, Deyu; Gao, Qingji; Luo, Qijun

    2017-06-01

    The baggage number needs to be checked automatically during baggage self-check-in. A fast airline baggage counting method is proposed in this paper using image segmentation based on height map which is projected by scanned baggage 3D point cloud. There is height drop in actual edge of baggage so that it can be detected by the edge detection operator. And then closed edge chains are formed from edge lines that is linked by morphological processing. Finally, the number of connected regions segmented by closed chains is taken as the baggage number. Multi-bag experiment that is performed on the condition of different placement modes proves the validity of the method.

  9. Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion.

    PubMed

    Park, Mihwa; Kim, Minjeong; Park, Jisun; Cho, Jinhyun

    2018-01-01

    Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/μL to 2000/μL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described. © Copyright: Yonsei University College of Medicine 2018.

  10. Single-drop optimization of protein crystallization.

    PubMed

    Meyer, Arne; Dierks, Karsten; Hilterhaus, Dierk; Klupsch, Thomas; Mühlig, Peter; Kleesiek, Jens; Schöpflin, Robert; Einspahr, Howard; Hilgenfeld, Rolf; Betzel, Christian

    2012-08-01

    A completely new crystal-growth device has been developed that permits charting a course across the phase diagram to produce crystalline samples optimized for diffraction experiments. The utility of the device is demonstrated for the production of crystals for the traditional X-ray diffraction data-collection experiment, of microcrystals optimal for data-collection experiments at a modern microbeam insertion-device synchrotron beamline and of nanocrystals required for data collection on an X-ray laser beamline.

  11. Initial puffing behaviors and subjective responses differ between an electronic nicotine delivery system and traditional cigarettes.

    PubMed

    Norton, Kaila J; June, Kristie M; O'Connor, Richard J

    2014-01-01

    Electronic nicotine delivery systems (ENDS) present an emerging issue for tobacco control and data on product use behaviors are limited. Participants (N = 38 enrolled; N = 16 compliant) completed three lab visits over 5 days and were asked to abstain from regular cigarettes for 72 hours in favor of ENDS (Smoke 51 TRIO - 3 piece, First Generation with 11 mg/ml filters). Lab visits included measurement of exhaled carbon monoxide (CO) and salivary cotinine concentration, questionnaire measures of regular cigarette craving after the 72 hour abstinence, and subjective product effects. Participants used a topography device to record puff volume, duration, flow rate, and inter-puff interval. Analyses revealed significant differences across products in puff count, average volume, total volume and inter-puff interval, with ENDS broadly showing a more intensive smoking pattern. Cigarette craving scores dropped significantly after smoking regular cigarettes, but not ENDS (p = .001), and subjective measures showed ENDS rated less favorably. CO boost, after ENDS use, decreased significantly (p < .001), and saliva cotinine significantly dropped between visits 1 and 3 (p < 0.001) after ENDS use relative to after cigarette smoking. For compliant and non-compliant participants, there was an average 82.0% [V1 - 16.1 cpd; V3 - 2.9 cpd] and average 73.9% [V1 - 20.3 cpd; V3 - 5.3 cpd] reduction in regular cigarette use per day during the ENDS trial period, respectively. The ENDS were smoked more intensively than own brand cigarettes, but delivered significantly less nicotineand were less satisfying. These findings have implications for the viability of certain ENDS as alternatives to cigarettes.

  12. AUTOMATIC COUNTING APPARATUS

    DOEpatents

    Howell, W.D.

    1957-08-20

    An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.

  13. Background compensation for a radiation level monitor

    DOEpatents

    Keefe, D.J.

    1975-12-01

    Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.

  14. A simple method for quantifying jump loads in volleyball athletes.

    PubMed

    Charlton, Paula C; Kenneally-Dabrowski, Claire; Sheppard, Jeremy; Spratford, Wayne

    2017-03-01

    Evaluate the validity of a commercially available wearable device, the Vert, for measuring vertical displacement and jump count in volleyball athletes. Propose a potential method of quantifying external load during training and match play within this population. Validation study. The ability of the Vert device to measure vertical displacement in male, junior elite volleyball athletes was assessed against reference standard laboratory motion analysis. The ability of the Vert device to count jumps during training and match-play was assessed via comparison with retrospective video analysis to determine precision and recall. A method of quantifying external load, known as the load index (LdIx) algorithm was proposed using the product of the jump count and average kinetic energy. Correlation between two separate Vert devices and three-dimensional trajectory data were good to excellent for all jump types performed (r=0.83-0.97), with a mean bias of between 3.57-4.28cm. When matched against jumps identified through video analysis, the Vert demonstrated excellent precision (0.995-1.000) evidenced by a low number of false positives. The number of false negatives identified with the Vert was higher resulting in lower recall values (0.814-0.930). The Vert is a commercially available tool that has potential for measuring vertical displacement and jump count in elite junior volleyball athletes without the need for time-consuming analysis and bespoke software. Subsequently, allowing the collected data to better quantify load using the proposed algorithm (LdIx). Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. CD4 decline is associated with increased risk of cardiovascular disease, cancer, and death in virally suppressed patients with HIV.

    PubMed

    Helleberg, Marie; Kronborg, Gitte; Larsen, Carsten S; Pedersen, Gitte; Pedersen, Court; Obel, Niels; Gerstoft, Jan

    2013-07-01

    The clinical implications of a considerable CD4 decline despite antiretroviral treatment and viral suppression are unknown. We aimed to test the hypothesis that a major CD4 decline could be a marker of cardiovascular disease or undiagnosed cancer. Patients with human immunodeficiency virus (HIV) were followed in the Danish nationwide, population-based cohort study in the period 1995-2010 with quarterly CD4 measurements. Associations between a CD4 decline of ≥30% and cardiovascular disease, cancer, and death were analyzed using Poisson regression with date of CD4 decline as a time-updated variable. We followed 2584 virally suppressed HIV patients for 13 369 person-years (PY; median observation time, 4.7 years). Fifty-six patients developed CD4 decline (incidence rate, 4.2/1000 PY [95% confidence interval {CI}, 3.2-5.4]). CD4 counts dropped from a median of 492 cells/µL to 240 cells/µL. CD8, CD3, and total lymphocyte counts dropped concomitantly. No HIV-related factors, apart from treatment with didanosine, were associated with CD4 decline. The risk of cardiovascular disease, cancer, and death increased markedly ≤6 months after CD4 decline (incidence rate ratio, 11.7 [95% CI, 3.6-37.4] and 13.7 [95% CI, 4.3-43.6], respectively, and mortality rate ratio 4.3 [95% CI, 1.1-17.6]). A major decline in CD4 count is associated with a marked increased risk of cardiovascular disease, cancer, and death among virally suppressed HIV patients.

  16. Real-time digital signal processing in multiphoton and time-resolved microscopy

    NASA Astrophysics Data System (ADS)

    Wilson, Jesse W.; Warren, Warren S.; Fischer, Martin C.

    2016-03-01

    The use of multiphoton interactions in biological tissue for imaging contrast requires highly sensitive optical measurements. These often involve signal processing and filtering steps between the photodetector and the data acquisition device, such as photon counting and lock-in amplification. These steps can be implemented as real-time digital signal processing (DSP) elements on field-programmable gate array (FPGA) devices, an approach that affords much greater flexibility than commercial photon counting or lock-in devices. We will present progress toward developing two new FPGA-based DSP devices for multiphoton and time-resolved microscopy applications. The first is a high-speed multiharmonic lock-in amplifier for transient absorption microscopy, which is being developed for real-time analysis of the intensity-dependence of melanin, with applications in vivo and ex vivo (noninvasive histopathology of melanoma and pigmented lesions). The second device is a kHz lock-in amplifier running on a low cost (50-200) development platform. It is our hope that these FPGA-based DSP devices will enable new, high-speed, low-cost applications in multiphoton and time-resolved microscopy.

  17. Acute organic brain syndrome due to drug-induced eosinophilia.

    PubMed

    Ng, S C; Lee, M K; Teh, A

    1989-11-01

    A 72 year old man developed acute organic brain syndrome associated with marked eosinophilia following self medication with a variety of drugs. Investigations revealed no other known causes of eosinophilia. Withdrawal of drugs resulted in dramatic drop in eosinophil count paralleled by clinical resolution of neurological problems. To our knowledge drug-induced eosinophilia has not previously been associated with acute organic brain syndrome.

  18. Acute organic brain syndrome due to drug-induced eosinophilia.

    PubMed Central

    Ng, S. C.; Lee, M. K.; Teh, A.

    1989-01-01

    A 72 year old man developed acute organic brain syndrome associated with marked eosinophilia following self medication with a variety of drugs. Investigations revealed no other known causes of eosinophilia. Withdrawal of drugs resulted in dramatic drop in eosinophil count paralleled by clinical resolution of neurological problems. To our knowledge drug-induced eosinophilia has not previously been associated with acute organic brain syndrome. PMID:2616421

  19. U.S. Army Medical Department Journal (April-June 2006)

    DTIC Science & Technology

    2006-06-01

    sensitive groupings, gastrointestinal, respiratory, febrile , dermatological, psychological, and cause- stratified traumatic injuries. It should be...suffering from (an) obscure febrile disease” which “defied definite identification.”1 Invariably, each of these Soldiers had been training at nearby... neutropenia occurring on or about the second or third day of symptoms. The total white blood cell count frequently dropped to about 3,000/µl and

  20. Maximizing Situational Awareness: Improving Situational Awareness with Global Positioning System Data in the Maritime Environment

    DTIC Science & Technology

    2009-03-01

    46 Figure 20. Blackberry device...installing an application developed in the Java Platform Micro Edition known as a MIDlet onto a commercial Blackberry phone. The Blackberry device transmits...hour and HVT is nearing checkpoint 1224 Contact of mobile team reveals possible intermittent signal drops may be due to travel through tunnels

  1. A Study of the Effects of Fieldbus Network Induced Delays on Control Systems

    ERIC Educational Resources Information Center

    Mainoo, Joseph

    2012-01-01

    Fieldbus networks are all-digital, two-way, multi-drop communication systems that are used to connect field devices such as sensors and actuators, and controllers. These fieldbus network systems are also called networked control systems (NCS). Although, there are different varieties of fieldbus networks such as Foundation Field Bus, DeviceNet, and…

  2. Microgravity experiment study on the vane type surface tension tank

    NASA Astrophysics Data System (ADS)

    Kang, Qi; Duan, Li; Rui, Wei

    Having advantages of low cost, convenience and high level of microgravity, the drop tower has become a significant microgravity experiment facility. National Microgravity Laboratory/CAS(NMLC) drop tower has 3.5s effective microgravity time, meanwhile the level of microgravity can reach 10 (-5) g. And the impact acceleration is less than 15g in the recovery period. The microgravity experiments have been conducted on the scaling model of vane type surface tension tank in NMLC’s drop tower. The efficiency of Propellant Management Devices (PMDs) was studied, which focus on the effects of Propellant Management Devices (PMDs), numbers of PMDs, contact angle, and liquid viscosity on the flow rate. The experimental results shown that the numbers of PMDs have little or no effect on the flow rate while the liquid is sufficient. The experiments about the influence of different charging ratio have been carried out while tank is placed positively and reversely, and we find the charging ratio has less effect on the capillary flow rate when the charging ratio is greater than 2%.

  3. Photon-counting intensified random-access charge injection device

    NASA Astrophysics Data System (ADS)

    Norton, Timothy J.; Morrissey, Patrick F.; Haas, Patrick; Payne, Leslie J.; Carbone, Joseph; Kimble, Randy A.

    1999-11-01

    At NASA GSFC we are developing a high resolution solar-blind photon counting detector system for UV space based astronomy. The detector comprises a high gain MCP intensifier fiber- optically coupled to a charge injection device (CID). The detector system utilizes an FPGA based centroiding system to locate the center of photon events from the intensifier to high accuracy. The photon event addresses are passed via a PCI interface with a GPS derived time stamp inserted per frame to an integrating memory. Here we present imaging performance data which show resolution of MCP tube pore structure at an MCP pore diameter of 8 micrometer. This data validates the ICID concept for intensified photon counting readout. We also discuss correction techniques used in the removal of fixed pattern noise effects inherent in the centroiding algorithms used and present data which shows the local dynamic range of the device. Progress towards development of a true random access CID (RACID 810) is also discussed and astronomical data taken with the ICID detector system demonstrating the photon event time-tagging mode of the system is also presented.

  4. Electrodialytic extraction of anionic pharmaceutical compounds from a single drop of whole blood using a supported liquid membrane.

    PubMed

    Imoto, Yurika; Nishiyama, Hiroka; Nakamura, Yukihide; Ohira, Shin-Ichi; Toda, Kei

    2018-05-01

    A method to introduce target analytes to a chromatograph from a single drop of whole blood was investigated for minimally invasive monitoring of anionic pharmaceuticals. In this work, salicylate and loxoprofen were examined as organic anions. A micro ion extractor (MIE) has been developed for extraction of inorganic trace anions from whole blood, but this device is not suitable for extraction of pharmaceuticals. In the present study, we improved and optimized the MIE device for organic anion extraction. Various supported liquid membranes were evaluated for use as the ion transfer membrane, with each membrane placed between a droplet sample (donor) and an acceptor solution. A supported liquid membrane of porous polypropylene impregnated with 1-butanol was selected. In addition, the methods for electric field creation and electrode contact were examined to improve the characteristics of the MIE device. The current and extraction time were also optimized. With the optimized method, salicylate and loxoprofen were successfully extracted from a single drop of whole blood. Changes in the concentrations of these pharmaceuticals in blood over time were monitored after administration. As only 25μL of whole blood was required for analysis, repeat measurements could be conducted to monitor changes in the concentrations. This MIE will be useful for monitoring pharmaceutical concentrations in blood. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Bacteriophage biocontrol of Listeria monocytogenes on soft ripened white mold and red-smear cheeses.

    PubMed

    Guenther, Susanne; Loessner, Martin J

    2011-03-01

    Soft-ripened cheeses belong to the type of food most often contaminated with Listeria monocytogenes, and they have been implicated in several outbreaks of listeriosis. Bacteriophages represent an attractive way to combat foodborne pathogens without affecting other properties of the food. We used the broad host range, virulent Listeria phage A511 for control of L. monocytogenes during the production and ripening phases of both types of soft-ripened cheeses, white mold (Camembert-type) cheese, as well as washed-rind cheese with a red-smear surface (Limburger-type). The surfaces of young, unripened cheese were inoculated with 10(1)-10(3) cfu/cm(2)L. monocytogenes strains Scott A (serovar 4b) or CNL 10(3)/2005 (serovar 1/2a). Phage was applied at defined time points thereafter, in single or repeated treatments, at 3 × 10(8) or 1 × 10(9) pfu/cm(2). With Scott A (10(3) cfu/cm(2)) and a single dose of A511 (3 × 10(8) pfu/cm(2)) on camembert-type cheese, viable counts dropped 2.5 logs at the end of the 21 day ripening period. Repeated phage application did not further inhibit the bacteria, whereas a single higher dose (1 × 10(9) pfu/cm(2)) was found to be more effective. On red-smear cheese ripened for 22 days, Listeria counts were down by more than 3 logs. Repeated application of A511 further delayed re-growth of Listeria, but did not affect bacterial counts after 22 days. With lower initial Listeria contamination (10(1)-10(2) cfu/cm(2)), viable counts dropped below the limit of detection, corresponding to more than 6 logs reduction compared to the control. Our data clearly demonstrate the potential of bacteriophage for biocontrol of L. monocytogenes in soft cheese.

  6. High variability in results of semen analysis in andrology laboratories in Tuscany (Italy): the experience of an external quality control (EQC) programme.

    PubMed

    Filimberti, E; Degl'Innocenti, S; Borsotti, M; Quercioli, M; Piomboni, P; Natali, I; Fino, M G; Caglieresi, C; Criscuoli, L; Gandini, L; Biggeri, A; Maggi, M; Baldi, E

    2013-05-01

    We report the results of the first three trials of an external quality control (EQC) programme performed in 71 laboratories executing semen analysis in Tuscany Region (Italy). At the end of the second trial, participants were invited to attend a teaching course illustrating and inviting to adhere to procedures recommended by WHO (V edition). Results of the first three trials of the EQC documented a huge variability in the procedures and the results. The highest variability was found for morphology (CV above 80% for all the trials), followed by count (CV of about 60% for all the trials) and motility (CV below 30% for all the trials). When results of sperm count and morphology were divided according to the used method, mean CV values did not show significant differences. CV for morphology dropped significantly at the third trial for most methods, indicating the usefulness of the teaching course for morphology assessment. Conversely, no differences were observed after the course for motility and for most methods to evaluate count, although CV values were lower at the second and third trial for the laboratories using the Burker cytometer. When results were divided according to tertiles of activity, the lowest mean bias values (difference between each laboratory result and the median value of the results) for count and morphology were observed for laboratories in the third tertile (performing over 200 semen analysis/year). Of interest, mean bias values for concentration dropped significantly at the third trial for low activity laboratories. In conclusion, lack of agreement of results of semen analysis in Tuscany is mainly because of the activity and the experience of the laboratory. Our study points out the importance of participating in EQC programmes and periodical teaching courses as well as the use of WHO recommended standardized procedures to increase precision and to allow the use of WHO reference values. © 2013 American Society of Andrology and European Academy of Andrology.

  7. Fluorescent intensity-based differential counting of FITC-doped silica nanoparticles: applications of CD4+ T-cell detection in microchip-type flowcytometers

    NASA Astrophysics Data System (ADS)

    Yun, Hoyoung; Bang, Hyunwoo; Lee, Won Gu; Lim, Hyunchang; Park, Junha; Lee, Joonmo; Riaz, Asif; Cho, Keunchang; Chung, Chanil; Han, Dong-Chul; Chang, Jun Keun

    2007-12-01

    Although CD4+ T-cells are an important target of HIV detection, there have been still major problems in making a diagnosis and monitoring in the third world and the region with few medical facilities. Then, it is necessary to use portable diagnosis devices at low cost when you put an enumeration of CD4+ T-cells. In general, the counting of CD4 below 200cells/uL makes it necessary to initiate antiretroviral treatment in adults (over 13 years old). However, lymphocyte subsets (including CD4 counts) of infants and young children are higher than those of adults. This fact shows the percentage of CD4+ T-cells of blood subsets, i.e., CD4/CD45%, CD4/CD8% or CD4/CD3% means a more reliable indicator of HIV infection than absolute counts in children. To know the percentage of CD4+ T-cell by using two fluorescent dyes of different emission wavelength, at least, one laser and two PMT detectors are in general needed. Then, it is so hard to develop a portable device like a 'toaster size' because this makes such a device more complex including many peripheral modules. In this study, we developed a novel technique to control the intensity of fluorescent dye-doped silica nanoparticles. I synthesized FITC-doped silica nanoparticles conjugated CD4 antibody 10 times brighter than FITC-conjugated CD45 antibody. With the difference of intensity of two fluorescent dyes, we measured two parameters by using only a single detector and laser. Most experiments were achieved with uFACS (microfabricated fluorescence-activated cell sorter) on an inverted microscope (IX71, Olympus). In conclusion, this method enables us to discriminate the difference between CD4 and CD45 in an intensity domain simultaneously. Furthermore, this technique would make it possible develop much cheaper and smaller devices which can count the number of CD4 T-cells.

  8. Tracking and Counting Motion for Monitoring Food Intake Based-On Depth Sensor and UDOO Board: A Comprehensive Review

    NASA Astrophysics Data System (ADS)

    Kassim, Muhammad Fuad bin; Norzali Haji Mohd, Mohd

    2017-08-01

    Technology is all about helping people, which created a new opportunity to take serious action in managing their health care. Moreover, Obesity continues to be a serious public health concern in the Malaysia and continuing to rise. Obesity has been a serious health concern among people. Nearly half of Malaysian people overweight. Most of dietary approach is not tracking and detecting the right calorie intake for weight loss, but currently used tools such as food diaries require users to manually record and track the food calories, making them difficult for daily use. We will be developing a new tool that counts the food intake bite by monitoring hand gesture and face jaw motion movement of caloric intake. The Bite count method showed a good significant that can lead to a successful weight loss by simply monitoring the bite taken during eating. The device used was Kinect Xbox One which used a depth camera to detect the motion on person hand and face during food intake. Previous studies showed that most of the method used to count bite device is worn type. The recent trend is now going towards non-wearable devices due to the difficulty when wearing devices and it has high false alarm ratio. The proposed system gets data from the Kinect that will be monitoring the hand and face gesture of the user while eating. Then, the gesture of hand and face data is sent to the microcontroller board to recognize and start counting bite taken by the user. The system recognizes the patterns of bite taken from user by following the algorithm of basic eating type either using hand or chopstick. This system can help people who are trying to follow a proper way to reduce overweight or eating disorders by monitoring their meal intake and controlling eating rate.

  9. A sampling device for counting insect egg clusters and measuring vertical distribution of vegetation

    Treesearch

    Robert L. Talerico; Robert W., Jr. Wilson

    1978-01-01

    The use of a vertical sampling pole that delineates known volumes and position is illustrated and demonstrated for counting egg clusters of N. sertifer. The pole can also be used to estimate vertical and horizontal coverage, distribution or damage of vegetation or foliage.

  10. Programmable random interval generator

    NASA Technical Reports Server (NTRS)

    Lindsey, R. S., Jr.

    1973-01-01

    Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.

  11. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.

  12. Scaling during capillary thinning of particle-laden drops

    NASA Astrophysics Data System (ADS)

    Thete, Sumeet; Wagoner, Brayden; Basaran, Osman

    2017-11-01

    A fundamental understanding of drop formation is crucial in many applications such as ink-jet printing, microfluidic devices, and atomization. During drop formation, the about-to-form drop is connected to the fluid hanging from the nozzle via a thinning filament. Therefore, the physics of capillary thinning of filaments is key to understanding drop formation and has been thoroughly studied for pure Newtonian fluids using theory, simulations, and experiments. In some of the applications however, the forming drop and hence the thinning filament may contain solid particles. The thinning dynamics of such particle-laden filaments differs radically from that of particle-free filaments. Moreover, our understanding of filament thinning in the former case is poor compared to that in the latter case despite the growing interest in pinch-off of particle-laden filaments. In this work, we go beyond similar studies and experimentally explore the impact of solid particles on filament thinning by measuring both the radial and axial scalings in the neck region. The results are summarized in terms of a phase diagram of capillary thinning of particle-laden filaments.

  13. Wireless Synchronization of a Multi-Pinhole Small Animal SPECT Collimation Device With a Clinical Scanner

    NASA Astrophysics Data System (ADS)

    DiFilippo, Frank P.; Patel, Sagar

    2009-06-01

    A multi-pinhole collimation device for small animal single photon emission computed tomography (SPECT) uses the gamma camera detectors of a standard clinical SPECT scanner. The collimator and animal bed move independently of the detectors, and therefore their motions must be synchronized. One approach is manual triggering of the SPECT acquisition simultaneously with a programmed motion sequence for the device. However, some data blurring and loss of image quality result, and true electronic synchronization is preferred. An off-the-shelf digital gyroscope with integrated Bluetooth interface provides a wireless solution to device synchronization. The sensor attaches to the SPECT gantry and reports its rotational speed to a notebook computer controlling the device. Software processes the rotation data in real-time, averaging the signal and issuing triggers while compensating for baseline drift. Motion commands are sent to the collimation device with minimal delay, within approximately 0.5 second of the start of SPECT gantry rotation. Test scans of a point source demonstrate an increase in true counts and a reduction in background counts compared to manual synchronization. The wireless rotation sensor provides robust synchronization of the collimation device with the clinical SPECT scanner and enhances image quality.

  14. Collecting Ground Samples for Balloon-Borne Instruments

    NASA Technical Reports Server (NTRS)

    Jones, Jack; Zimmerman, Wayne; Wu, Jiunn Jenq

    2009-01-01

    A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

  15. Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

    PubMed

    Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha

    2015-10-01

    Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.

  16. Enhancing the Linear Dynamic Range in Multi-Channel Single Photon Detector beyond 7OD

    PubMed Central

    Gudkov, Dmytro; Gudkov, George; Gorbovitski, Boris; Gorfinkel, Vera

    2015-01-01

    We present design, implementation, and characterization of a single photon detector based on 32-channel PMT sensor [model H7260-20, Hamamatsu]. The developed high speed electronics enables the photon counting with linear dynamic range (LDR) up to 108count/s per detector's channel. The experimental characterization and Monte-Carlo simulations showed that in the single photon counting mode the LDR of the PMT sensor is limited by (i) “photon” pulse width (current pulse) of 900ps and (ii) substantial decrease of amplitudes of current pulses for count rates exceeding 108 count/s. The multi-channel architecture of the detector and the developed firm/software allow further expansion of the dynamic range of the device by 32-fold by using appropriate beam shaping. The developed single photon counting detector was tested for the detection of fluorescence labeled microbeads in capillary flow. PMID:27087788

  17. The influence of flow modification on air and PCM temperatures in an accumulative heat exchanger

    NASA Astrophysics Data System (ADS)

    Borcuch, Marcin; Musiał, Michał; Sztekler, Karol; Kalawa, Wojciech; Gumuła, Stanisław; Stefański, Sebastian

    2018-06-01

    The paper presents the influence of flow modification on the operation of an accumulative heat exchanger. This device can be used as a regenerator in ventilation and air supply systems. A heat exchanger uses ceresine (a mixture of paraffins) as a phase change material (PCM). The aim of this research was to determine the effect of flow modification on temperature distribution and pressure drops in the device. The introduction contains a short description of the test stand used, including the accumulative heat exchanger, the guide vanes, and the locations of measurement and control equipment. We found that additional objects limited vortex structures, increased the inside temperature, and dropped the pressure along the heat exchanger. Guidelines for further research are proposed and briefly discussed.

  18. [Use of an aerosol generator (Guard) to control injurious insects in forestry, agriculture, and medical disinsection].

    PubMed

    Abdraziakov, O N; Ermishev, Iu V; Levkov, P A

    2012-01-01

    The Guard aerosol generator is a universal multioperational device without a field-of-use restriction in the application of permitted chemical and biological substances, by combining the function of a controlled dispersion aerosol generator and a remote small- and large-drop sprayer in one mechanism and can use aerosol pesticides. The drop fractionation range is as follows: 3-50, 50-100, 100-300, and 200-400 microm for aerosol, dead water, small-drop, and large-drop spraying, respectively, with smooth and step control of working liquid drops. Treatment using the Guard generator has been shown to be highly effective against agricultural and forestry pests. This paper describes the advantages of the Guard sprayer over those of the conventional air and ground ones. The long-term use of the Guard generator to control mosquitoes and ticks in the Tyumen region could substantially improve the epidemiological situation of tick-borne infections and protect children's recreation centers from attacks of bloodsuckers.

  19. Microgravity

    NASA Image and Video Library

    2002-08-07

    A student assembles a Lego (TM) Challenge device designed to operate in the portable drop tower demonstrator as part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  20. Effect of Electromigration on the Type of Drop Failure of Sn-3.0Ag-0.5Cu Solder Joints in PBGA Packages

    NASA Astrophysics Data System (ADS)

    Huang, M. L.; Zhao, N.

    2015-10-01

    Board-level drop tests of plastic ball grid array (PBGA) packages were performed in accordance with the Joint Electron Devices Engineering Council standard to investigate the effect of electromigration (EM) on the drop reliability of Sn-3.0Ag-0.5Cu solder joints with two substrate surface finishes, organic solderability preservative (OSP) and electroless nickel electroless palladium immersion gold (ENEPIG). In the as-soldered state, drop failures occurred at the substrate sides only, with cracks propagating within the interfacial intermetallic compound (IMC) layer for OSP solder joints and along the IMC/Ni-P interface for ENEPIG solder joints. The drop lifetime of OSP solder joints was approximately twice that of ENEPIG joints. EM had an important effect on crack formation and drop lifetime of the PBGA solder joints. ENEPIG solder joints performed better in drop reliability tests after EM, that is, the drop lifetime of ENEPIG joints decreased by 43% whereas that of OSP solder joints decreased by 91%, compared with the as-soldered cases. The more serious polarity effect, i.e., excessive growth of the interfacial IMC at the anode, was responsible for the sharper decrease in drop lifetime. The different types of drop failure of PBGA solder joints before and after EM, including the position of initiation and the propagation path of cracks, are discussed on the basis of the growth behavior of interfacial IMC.

  1. Blood pressure circadian pattern and physical exercise assessment by accelerometer and 7-day physical activity recall scale.

    PubMed

    García-Ortiz, Luis; Recio-Rodríguez, José I; Puig-Ribera, Anna; Lema-Bartolomé, Jorge; Ibáñez-Jalón, Elisa; González-Viejo, Natividad; Guenaga-Saenz, Nahia; Agudo-Conde, Cristina; Patino-Alonso, Maria C; Gomez-Marcos, Manuel A

    2014-05-01

    The relationship between regular physical activity, measured objectively and by self-report, and the circadian pattern of 24-hour ambulatory arterial blood pressure (BP) has not been clarified. We performed a cross-sectional study in a cohort of healthy patients. We included 1,345 patients from the EVIDENT study (mean age 55 ± 14 years; 59.3% women). Physical activity was assessed using the 7-day physical activity recall (PAR) questionnaire (metabolic equivalents (MET)/hour/week) and the Actigraph GT3X accelerometer (counts/minute) for 7 days; ambulatory arterial BP was measured with a radial tonometer (B-pro device). The dipper-pattern patients showed a higher level of activity than nondipper patients, as assessed by accelerometer and 7-day PAR. Physical activity measures correlated positively with the percent drop in systolic BP (SBP; ρ = 0.19 to 0.11; P < 0.01) and negatively with the systolic and diastolic sleep to wake ratios (ρ = -0.10 to -0.18; P < 0.01) and heart rate (ρ = -0.13; P < 0.01). In logistic regression, considering the circadian pattern (1, dipper; 0, nondipper) as the dependent variable, the odds ratio of the third tertile of counts/minute was 1.79 (95% confidence interval [CI], 1.35-2.38; P < 0.01) and of MET/hour/week was 1.33 (95% CI, 1.01-1.75; P = 0.04) after adjustment for confounding variables. Physical activity, as evaluated by both the accelerometer and the 7-day PAR, was associated with a more marked nocturnal BP dip and, accordingly, a lower SBP and diastolic BP sleep to wake ratio. Clinical Trials.gov Identifier: NCT01083082.

  2. [Use of filgrastim, granulocyte colony stimulating factor (G-CSF), in radiotherapy to reduce drop-outs because of radiogenic leukopenia].

    PubMed

    Gava, A; Bertossi, L; Ferrarese, F; Coghetto, F; Marazzato, G; Andrulli, A D; Zorat, P L

    1998-03-01

    Radiotherapy patients are at risk of developing leukopenia, which risk depends on the irradiated volume, the rate of irradiated bone marrow and the radiation dose. Radiogenic leukopenia may cause radiotherapy drop-out, with consequent effects, on local tumor control and clinical outcome. The introduction of granulocyte growth factors, such as filgrastim, has permitted to accelerate normal neutrophil count recovery in irradiation-related neutropenia both in vitro and animal models; clinical experience in humans is still lacking, relative to both indications and scheduling. In the Oncologic Radiotherapy Department of Treviso Hospital, 31 patients irradiated for Hodgkin disease, rectal cancer and other malignancies, who presented leukopenia requiring treatment discontinuation, were given filgrastim to assess its actual effect in avoiding further drop-outs and to compare two administration schedules (2 or 3 vials, 30 MIU, weekly). Filgrastim treatment was continued throughout the radiotherapy cycles, for 1 to 5 weeks. Eighteen patients had received previous chemotherapy and 11 were undergoing concurrent 5-fluorouracil chemotherapy-irradiation. A mean 203% increase in leukocyte count was observed (136% in the patients treated with 2 vials/week and 274% in those receiving 3 vials/week); this increase was more apparent in women that in men (256% versus 91%) and slightly higher in patients 50 years old and with target volumes < 5000 ml. Filgrastin treatment was well tolerated by all patients, with no discontinuations due to adverse effects; 9 patients (29%) reported skeletal pain, which was marked in 2 of them only. Eighty percent of patients completed all the radiotherapy cycles with no discontinuation, while 6 patients dropped out because leukopenia persisted. Biweekly filgrastim administration was effective to prevent unscheduled radiotherapy discontinuation in 75% of patients and triweekly administration was effective in 86% of patients. In our experience, filgrastim administration was well tolerated and effective in decreasing the irradiation drop-outs caused by treatment-related leukopenia. Since this drug is rather expensive, we decided to use routinely the lower dosage of biweekly administration (with one vial given on Friday and Saturday, to permit neutrophil recovery during the day off) and to reserve the higher dosage (3 vials a week) to the patients with large body areas, big target volumes and persistent leukopenia during previous chemotherapy.

  3. The Manhattan Project

    NASA Astrophysics Data System (ADS)

    Reed, B. Cameron

    2014-10-01

    The Manhattan Project was the United States Army’s program to develop and deploy nuclear weapons during World War II. In these devices, which are known popularly as ‘atomic bombs’, energy is released not by a chemical explosion but by the much more violent process of fission of nuclei of heavy elements via a neutron-mediated chain-reaction. Three years after taking on this project in mid-1942, the Army’s Manhattan Engineer District produced three nuclear bombs of two different designs. Two of these devices were fueled with the 239 isotope of the synthetic element plutonium, while the third employed the rare 235 isotope of uranium. One of the plutonium devices, code-named Trinity, was detonated in a test in southern New Mexico on 16 July 1945; this was the world’s first nuclear explosion. Three weeks later, on 6 August, the uranium bomb, Little Boy, was dropped on the Japanese city of Hiroshima. On 9 August the second plutonium device, Fat Man, was dropped on Nagasaki. Together, the two bombings killed over 100 000 people and were at least partially responsible for the Japanese government’s 14 August decision to surrender. This article surveys, at an undergraduate level, the science and history of the Manhattan Project.

  4. Basophil degranulation induced by oral poison ivy antigen.

    PubMed

    Shelley, W B; Resnik, S S

    1965-08-01

    Seven subjects shown by patch test to be sensitive to poison ivy oleoresin were challenged with graded oral doses of ivy extract. In each instance the circulating basophil leukocytes showed significant degranulation within one hour of challenge. This finding was interpreted as evidence of the presence of immediate-type circulating antibody to ivy antigen in these subjects. No drop in the absolute basophil count was noted, but with higher oral doses the degranulation persisted for several days. Thirteen control subjects showed no change in the basophil morphology or count, indicating that the resin at these levels was not toxic to this cell. All but one of the sensitive subjects showed objective patch test evidence of hyposensitization following the intensive three-week course of oral poison ivy antigen.

  5. Sustained CD4+ T cell-driven lymphopenia without a compensatory IL-7/IL-15 response among high-grade glioma patients treated with radiation and temozolomide

    PubMed Central

    Ellsworth, Susannah; Balmanoukian, Ani; Kos, Ferdynand; Nirschl, Christopher J; Nirschl, Thomas R; Grossman, Stuart A; Luznik, Leo; Drake, Charles G

    2014-01-01

    Prolonged lymphopenia correlating with decreased survival commonly occurs among glioma patients undergoing radiation therapy (RT) and temozolomide (TMZ) treatment. To better understand the pathophysiology of this phenomenon, we prospectively monitored serum cytokine levels and lymphocyte subsets in 15 high-grade glioma patients undergoing combined radiation and TMZ (referred to as RT/TMZ) treatment. Sufficient data for analysis were acquired from 11 of the patients initially enrolled. Lymphocyte phenotyping data were obtained using cytofluorometric analysis and serum cytokine levels were measured using the a multiplex bead-based assays. Total lymphocyte counts (TLCs) were > 1000 cells per μL peripheral blood in 10/11 patients at baseline, but dropped significantly after treatment. Specifically, after RT/TMZ therapy, the TLCs were found to be < 500 cells/μL in 2/11 patients, 500–1000 cells/μL in 7/11 patients, and > 1000 cells/μL in the remaining 2 patients. Among residual mononuclear blood cells, we observed a proportional drop in B and CD4+ T cells but not in CD8+ T lymphocytes. Natural killer cells remained to near-to-baseline levels and there was a transient and slight (insignificant) increase in regulatory T cells (Tregs). The circulating levels of IL-7 and IL-15 remained low despite marked drops in both the total and CD4+ T lymphocyte counts. Thus, patients with malignant glioma undergoing RT/TMZ treatment exhibit a marked decline in TLCs, affecting both CD4+ T cells and B lymphocytes, in the absence of a compensatory increase in interleukin-7 levels. The failure to mount an appropriate homeostatic cytokine response may be responsible for the prolonged lymphopenia frequently observed in these patients. PMID:24790790

  6. The Effect of Nozzle Design and Operating Conditions on the Atomization and Distribution of Fuel Sprays

    NASA Technical Reports Server (NTRS)

    Lee, Dana W

    1933-01-01

    The atomization and distribution characteristics of fuel sprays from automatic injection valves for compression-ignition engines were determined by catching the fuel drops on smoked-glass plates, and then measuring and counting the impressions made in the lampblack. The experiments were made in an air-tight chamber in which the air density was raised to values corresponding to engine conditions.

  7. What Should Count as Worthwhile Knowledge in Determining a Curriculum for Supporting Out-of-school Children and Youth?

    ERIC Educational Resources Information Center

    Nampota, Dorothy Cynthia

    2009-01-01

    Due to the increasing number of children and youth dropping out of school, the Malawi government came up with a strategy to address their learning needs through non-formal means in its Education for All (EFA) plan. This resulted in the introduction of a three-year cycle pilot programme known as Complementary Basic Education (CBE). Funded by GTZ, a…

  8. Fracking: Unintended Consequences for Local Communities

    DTIC Science & Technology

    2016-12-01

    holistic impact of fracking on the environment and socioeconomics of local communities at the epicenter of shale oil production . This study included...socioeconomics of local communities at the epicenter of shale oil production . This study included an evaluation of crucial environmental issues...un ts M ill io n Ba rr el s Annual Oil Production North Dakota Annual Average Rig Count 38 biggest daily drop ever, a 6% decrease, producing 1.04

  9. CVD facility electrical system captor/dapper study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SINGH, G.

    1999-10-28

    Project W-441, CVD Facility Electrical System CAPTOWDAPPER Study validates Meier's hand calculations. This study includes Load flow, short circuit, voltage drop, protective device coordination, and transient motor starting (TMS) analyses.

  10. 2D dark-count-rate modeling of PureB single-photon avalanche diodes in a TCAD environment

    NASA Astrophysics Data System (ADS)

    Knežević, Tihomir; Nanver, Lis K.; Suligoj, Tomislav

    2018-02-01

    PureB silicon photodiodes have nm-shallow p+n junctions with which photons/electrons with penetration-depths of a few nanometer can be detected. PureB Single-Photon Avalanche Diodes (SPADs) were fabricated and analysed by 2D numerical modeling as an extension to TCAD software. The very shallow p+ -anode has high perimeter curvature that enhances the electric field. In SPADs, noise is quantified by the dark count rate (DCR) that is a measure for the number of false counts triggered by unwanted processes in the non-illuminated device. Just like for desired events, the probability a dark count increases with increasing electric field and the perimeter conditions are critical. In this work, the DCR was studied by two 2D methods of analysis: the "quasi-2D" (Q-2D) method where vertical 1D cross-sections were assumed for calculating the electron/hole avalanche-probabilities, and the "ionization-integral 2D" (II-2D) method where crosssections were placed where the maximum ionization-integrals were calculated. The Q-2D method gave satisfactory results in structures where the peripheral regions had a small contribution to the DCR, such as in devices with conventional deepjunction guard rings (GRs). Otherwise, the II-2D method proved to be much more precise. The results show that the DCR simulation methods are useful for optimizing the compromise between fill-factor and p-/n-doping profile design in SPAD devices. For the experimentally investigated PureB SPADs, excellent agreement of the measured and simulated DCR was achieved. This shows that although an implicit GR is attractively compact, the very shallow pn-junction gives a risk of having such a low breakdown voltage at the perimeter that the DCR of the device may be negatively impacted.

  11. Measurement correction method for force sensor used in dynamic pressure calibration based on artificial neural network optimized by genetic algorithm

    NASA Astrophysics Data System (ADS)

    Gu, Tingwei; Kong, Deren; Shang, Fei; Chen, Jing

    2017-12-01

    We present an optimization algorithm to obtain low-uncertainty dynamic pressure measurements from a force-transducer-based device. In this paper, the advantages and disadvantages of the methods that are commonly used to measure the propellant powder gas pressure, the applicable scope of dynamic pressure calibration devices, and the shortcomings of the traditional comparison calibration method based on the drop-weight device are firstly analysed in detail. Then, a dynamic calibration method for measuring pressure using a force sensor based on a drop-weight device is introduced. This method can effectively save time when many pressure sensors are calibrated simultaneously and extend the life of expensive reference sensors. However, the force sensor is installed between the drop-weight and the hammerhead by transition pieces through the connection mode of bolt fastening, which causes adverse effects such as additional pretightening and inertia forces. To solve these effects, the influence mechanisms of the pretightening force, the inertia force and other influence factors on the force measurement are theoretically analysed. Then a measurement correction method for the force measurement is proposed based on an artificial neural network optimized by a genetic algorithm. The training and testing data sets are obtained from calibration tests, and the selection criteria for the key parameters of the correction model is discussed. The evaluation results for the test data show that the correction model can effectively improve the force measurement accuracy of the force sensor. Compared with the traditional high-accuracy comparison calibration method, the percentage difference of the impact-force-based measurement is less than 0.6% and the relative uncertainty of the corrected force value is 1.95%, which can meet the requirements of engineering applications.

  12. Electronic compliance monitoring of topical treatment after ophthalmic surgery.

    PubMed

    Hermann, Manuel Marcel; Ustündag, Can; Diestelhorst, Michael

    2010-08-01

    The success of many medical treatments is built on compliance. Electronic monitoring is the most accurate tool to quantify compliance by measuring adherence. In order to assess the efficiency of a recently introduced miniature monitoring device for eye drop application, we evaluated adherence in ophthalmic patients undergoing post-operative short-term topical treatment. This pilot study enrolled 30 outpatients (mean age 61.8 +/- 18.5 years) after cataract (n = 24) and glaucoma filtration surgery (n = 6) applying fixed-combination eye drops containing prednisolone and gentamicin five times daily for 2 weeks. Patients received eye drops in conventional bottles each equipped with a miniature monitoring device recording events of application. Two patients failed to bring back the monitoring device; therefore data collected from only 28 patients could be examined. Data showed highly variable results with a mean dose compliance of 50.2%. Dose compliance was below 25% in approximately one out of five patients. Four cataract patients, but no glaucoma patient, discontinued therapy prematurely. The observed mean dosage interval was calculated for each patient and ranged 4.6-19.7 h. Thirty percent of analysed dosage intervals exceeded 12.0 h. Different patterns of compliance behaviour-like early non-persistence, drug holiday and low treatment frequency could be identified and illustrated using electronic data. Age or gender did not significantly influence compliance rates. Our pilot study demonstrates successful electronic compliance monitoring using a technology capable of continuous data recording over weeks of treatment. The low compliance rate for a relevant part of the patients demonstrates the necessity to study and improve compliance in ophthalmology. In future, new application methods and electronic application devices may improve treatment response in eye care.

  13. [How to promote the respect of good infusion practices by meeting health care professionals?].

    PubMed

    Le Reste, C; Fiedler, A; Dubois, S; Dewailly, A; Le Du, I; Cogulet, V

    2016-05-01

    Health care professionals often forget that there are risks associated with infusion therapy even if it is a common care. In order to assess this practice and to draw potential improvement actions, an audit of local gravity-flow intravenous infusion practices was conducted. The audit, based on a grid including 66 items from the medical prescription to the end of the infusion therapy administration, was conducted in the 6 units which use the most gravity-flow intravenous infusion devices. A multidisciplinary working group was created to decide and organize priority corrective measures in order to improve infusion practices and quality of healthcare. The audit enabled to observe 90hours of nurse's practices (96 infusions) and highlighted heterogeneity in infusion, in some cases inappropriate infusion practices and misuse of infusion devices. We found 4 main issues: labelling infusion therapy, training of health care professionals on good practices, support the purchase of infusion pumps and standardize perfusion line. An interactive educational program for nurses (workshops) was organized to enhance the respect of good practices: infusion identification at any time, respect of hygiene rules, flow rate regulation by counting drops, appropriate use of pumps and flow rate regulators. The audit drew up work priorities. The workshops made easier exchanges between professionals and had a warm welcome that's why it is essential to carry on such training. This collaborative approach between pharmacists, nurses, hygienists and biomedical technicians contribute to drug management improvement and promote optimal patient care. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  14. Silicon Quantum Dots with Counted Antimony Donor Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Meenakshi; Pacheco, Jose L.; Perry, Daniel Lee

    2015-10-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

  15. High count-rate study of two TES x-ray microcalorimeters with different transition temperatures

    NASA Astrophysics Data System (ADS)

    Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.; Sadleir, John E.; Smith, Stephen J.; Wassell, Edward J.

    2017-10-01

    We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures (T c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T cs had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.3 eV at 6 keV from lower and higher T c devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the so-called event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96% throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T c (faster) device, and 5.8 eV FWHM with 97% throughput with the lower T c (slower) device at 722 Hz.

  16. Optimizing autologous nonmobilized mononuclear cell collections for cellular therapy in pediatric patients with high-risk leukemia.

    PubMed

    Even-Or, Ehud; Di Mola, Maria; Ali, Muhammad; Courtney, Sarah; McDougall, Elizabeth; Alexander, Sarah; Schechter, Tal; Whitlock, James A; Licht, Christoph; Krueger, Joerg

    2017-06-01

    The manufacturing of cellular products for immunotherapy, such as chimeric antigen receptor T cells, requires successful collection of mononuclear cells. Collections from children with high-risk leukemia present a challenge, especially because the established COBE Spectra apheresis device is being replaced by the novel Spectra Optia device (Optia) in many institutions. Published experience for mononuclear cell collections in children with Optia is lacking. Our aim was to compare the two collection devices and describe modified settings on the Optia to optimize mononuclear cell collections. As a quality initiative, we retrospectively collected and compared data from mononuclear cell collections on both devices. Collected data included patient's clinical characteristics; collection parameters, including precollection lymphocyte/CD3 counts, total blood volumes processed, runtimes, and side effects (including complete blood count and electrolyte changes); and product characteristics, including volumes and cell counts. Collection efficiencies and collection ratios were calculated. Twenty-six mononuclear cell collections were performed on 20 pediatric patients: 11 with COBE and 15 with Optia. Adequate mononuclear cell products were successfully collected with a single procedure from all patients except one, with mean calculated mononuclear cell collection efficiency that was significantly higher from Optia collections compared with COBE collections (57.9 ± 4.6% vs 40.3 ± 6.2%, respectively; p = 0.04). CD3-positive yields were comparable on both machines (p = 0.34) with significantly smaller blood volumes processed on Optia. Collected products had larger volumes on Optia. No significant side effects attributed to the procedure were noted. Mononuclear cell apheresis using the Optia device in children is more efficient and is as safe as that with the COBE device. © 2017 AABB.

  17. Medipix2 based CdTe microprobe for dental imaging

    NASA Astrophysics Data System (ADS)

    Vykydal, Z.; Fauler, A.; Fiederle, M.; Jakubek, J.; Svestkova, M.; Zwerger, A.

    2011-12-01

    Medical imaging devices and techniques are demanded to provide high resolution and low dose images of samples or patients. Hybrid semiconductor single photon counting devices together with suitable sensor materials and advanced techniques of image reconstruction fulfil these requirements. In particular cases such as the direct observation of dental implants also the size of the imaging device itself plays a critical role. This work presents the comparison of 2D radiographs of tooth provided by a standard commercial dental imaging system (Gendex 765DC X-ray tube with VisualiX scintillation detector) and two Medipix2 USB Lite detectors one equipped with a Si sensor (300 μm thick) and one with a CdTe sensor (1 mm thick). Single photon counting capability of the Medipix2 device allows virtually unlimited dynamic range of the images and thus increases the contrast significantly. The dimensions of the whole USB Lite device are only 15 mm × 60 mm of which 25% consists of the sensitive area. Detector of this compact size can be used directly inside the patients' mouth.

  18. Microgravity

    NASA Image and Video Library

    2002-08-07

    Two students show the Lego (TM) Challenge device they designed and built to operate in the portable drop tower demonstrator as part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  19. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase 3 Wiaman Seat

    DTIC Science & Technology

    2016-07-01

    711 HPW/RHCPT) and their in-house technical support contractor , Infoscitex, conducted a series of tests to identify the performance capabilities of...Cell Seat Configuration Drop Ht . (in) Mean Peak Acceleration (G) Mean Velocity Change (ft/s) SH1 WS1 20 80.08 ± 3.71 13.54 ± 0.49 SH2...6. Test Matrix for VID Response with WS2 Test Cell Seat (Felt) Configuration Drop Ht . (in) Mean Peak Acceleration (G

  20. Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model.

    PubMed

    Wilkinson, Holly N; McBain, Andrew J; Stephenson, Christian; Hardman, Matthew J

    2016-11-01

    Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze using a wounded porcine skin biofilm model with standardized application parameters. Biofilm removal was determined using a surface viability assay, bacterial counts, histological assessment, and scanning electron microscopy (SEM). Results: Quantitative analysis revealed that monofilament debriding devices outperformed the standard gauze, resulting in up to 100-fold greater reduction in bacterial counts. Interestingly, histological and morphological analyses suggested that debridement not only removed bacteria, but also differentially disrupted the bacterially-derived extracellular polymeric substance. Finally, SEM of post-debridement monofilaments showed structural changes in attached bacteria, implying a negative impact on viability. Innovation: This is the first study to combine controlled and defined debridement application with a biologically relevant ex vivo biofilm model to directly compare monofilament debriding devices. Conclusion: These data support the use of monofilament debriding devices for the removal of established wound biofilms and suggest variable efficacy towards biofilms composed of different species of bacteria.

  1. Voltage transfer function as an optical method to characterize electrical properties of liquid crystal devices.

    PubMed

    Bateman, J; Proctor, M; Buchnev, O; Podoliak, N; D'Alessandro, G; Kaczmarek, M

    2014-07-01

    The voltage transfer function is a rapid and visually effective method to determine the electrical response of liquid crystal (LC) systems using optical measurements. This method relies on crosspolarized intensity measurements as a function of the frequency and amplitude of the voltage applied to the device. Coupled with a mathematical model of the device it can be used to determine the device time constants and electrical properties. We validate the method using photorefractive LC cells and determine the main time constants and the voltage dropped across the layers using a simple nonlinear filter model.

  2. Performance of a capillary propellant management device with hydrazine

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.

    1979-01-01

    The propellant management device that was successfully used in the Viking Orbiter spacecraft was selected for the main propulsion system of the Teleoperator Retrieval System (TRS). Due to differences in the missions and different propellants, the operation of this sheet metal vane device required reverification for the TRS application. An analytical investigation was performed considering the adverse acceleration environment and the high contract angle of the hydrazine propellant. Drop tower tests demonstrated that the device would provide propellant acquisition while the TRS was docked with Skylab, but its operation would have to be supplemented through propellant settling when free-flying.

  3. Supercrystallization of KCl from solution irradiated by soft X-rays

    NASA Astrophysics Data System (ADS)

    Janavičius, A. J.; Rinkūnas, R.; Purlys, R.

    2016-10-01

    The X-rays influence on KCl crystallization in a saturated water solution has been investigated for the aim of comparing it with previously considered NaCl crystallization. The rate of crystallization has been measured in the drying drop in the solution activated by the irradiation. We have measured the influence of the irradiation time of the solution on the rates of KCl crystallization as well as the beginning of the crystallization processes on drying drops. For a longer irradiation time of the solution early crystallization in the drops occurs. A saturated water solution of KCl was irradiated with the diffractometer DRON-3M (Russian device) and this had a great influence on the two-step processes of crystallization. The ionization of the solution by soft X-rays can produce ions, metastable radicals in water, excited crystals' seeds and vacancies in growing crystals by Auger's effect. The X-rays generate a very fast crystallization in the drying drop.

  4. Green chemistry and nanofabrication in a levitated Leidenfrost drop

    NASA Astrophysics Data System (ADS)

    Abdelaziz, Ramzy; Disci-Zayed, Duygu; Hedayati, Mehdi Keshavarz; Pöhls, Jan-Hendrik; Zillohu, Ahnaf Usman; Erkartal, Burak; Chakravadhanula, Venkata Sai Kiran; Duppel, Viola; Kienle, Lorenz; Elbahri, Mady

    2013-10-01

    Green nanotechnology focuses on the development of new and sustainable methods of creating nanoparticles, their localized assembly and integration into useful systems and devices in a cost-effective, simple and eco-friendly manner. Here we present our experimental findings on the use of the Leidenfrost drop as an overheated and charged green chemical reactor. Employing a droplet of aqueous solution on hot substrates, this method is capable of fabricating nanoparticles, creating nanoscale coatings on complex objects and designing porous metal in suspension and foam form, all in a levitated Leidenfrost drop. As examples of the potential applications of the Leidenfrost drop, fabrication of nanoporous black gold as a plasmonic wideband superabsorber, and synthesis of superhydrophilic and thermal resistive metal-polymer hybrid foams are demonstrated. We believe that the presented nanofabrication method may be a promising strategy towards the sustainable production of functional nanomaterials.

  5. Green chemistry and nanofabrication in a levitated Leidenfrost drop

    PubMed Central

    Abdelaziz, Ramzy; Disci-Zayed, Duygu; Hedayati, Mehdi Keshavarz; Pöhls, Jan-Hendrik; Zillohu, Ahnaf Usman; Erkartal, Burak; Chakravadhanula, Venkata Sai Kiran; Duppel, Viola; Kienle, Lorenz; Elbahri, Mady

    2013-01-01

    Green nanotechnology focuses on the development of new and sustainable methods of creating nanoparticles, their localized assembly and integration into useful systems and devices in a cost-effective, simple and eco-friendly manner. Here we present our experimental findings on the use of the Leidenfrost drop as an overheated and charged green chemical reactor. Employing a droplet of aqueous solution on hot substrates, this method is capable of fabricating nanoparticles, creating nanoscale coatings on complex objects and designing porous metal in suspension and foam form, all in a levitated Leidenfrost drop. As examples of the potential applications of the Leidenfrost drop, fabrication of nanoporous black gold as a plasmonic wideband superabsorber, and synthesis of superhydrophilic and thermal resistive metal–polymer hybrid foams are demonstrated. We believe that the presented nanofabrication method may be a promising strategy towards the sustainable production of functional nanomaterials. PMID:24169567

  6. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, A K; Koniczek, M; Antonuk, L E

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailedmore » circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.« less

  7. How frequently external ventricular drainage device should be changed in children with ventriculoperitonel shunt infection?

    PubMed Central

    Gulsen, Ismail; Ak, Hakan; Demir, Nihat; Sosuncu, Enver; Arslan, Mehmet

    2015-01-01

    Objective: The purpose of the presenting study was to determine how frequently external ventricular drainage (EVD) device should be changed in children with ventriculopertienal shunt (VPS) infection during prolonged intravenous antimicrobial therapy. Methods: In this retrospective study, 25 children with VPS infection were evaluated between January 2012 and December 2013. In these children VPS was surgically removed and appropriate antimicrobial therapy was administered according to cerebrospinal culture results. Data noted about how frequently EVD device had been changed, the number of cells on direct observation of cerebrospinal fluid (CSF), glucose and protein levels of CSF, and CSF culture results were obtained from patients’ records. Results: Total 25 children were included in the study. The median age was three months (1 and 65 months). In 44% of children, Staphylococcus epidermidis was isolated. During treatment period, EVD catheter has changed one to six times. A total of 68 EVD catheters were changed in these patients. When the duration of ventriculostomy catheter and leukocyte count in CSF were evaluated on daily basis, leukocyte count was decreased 5 units per day in children whose catheter remained less than 10 days. However, in children whose catheter remained more than 10 days leukocyte count was decreased 2.21 units per day. Conclusions: In children with VPS infection, EVD device should be changed at every 10 days for the rapid resolution of the infection. PMID:26101506

  8. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy.

    PubMed

    Martin, Klaus Daniel; Polanski, Witold Henryk; Schulz, Anne-Kathrin; Jöbges, Michael; Hoff, Hansjoerg; Schackert, Gabriele; Pinzer, Thomas; Sobottka, Stephan B

    2016-01-01

    OBJECT The ActiGait drop foot stimulator is a promising technique for restoration of lost ankle function by an implantable hybrid stimulation system. It allows ankle dorsiflexion by active peroneal nerve stimulation during the swing phase of gait. In this paper the authors report the outcome of the first prospective study on a large number of patients with stroke-related drop foot. METHODS Twenty-seven patients who experienced a stroke and with persisting spastic leg paresis received an implantable ActiGait drop foot stimulator for restoration of ankle movement after successful surface test stimulation. After 3 to 5 weeks, the stimulator was activated, and gait speed, gait endurance, and activation time of the system were evaluated and compared with preoperative gait tests. In addition, patient satisfaction was assessed using a questionnaire. RESULTS Postoperative gait speed significantly improved from 33.9 seconds per 20 meters to 17.9 seconds per 20 meters (p < 0.0001), gait endurance from 196 meters in 6 minutes to 401 meters in 6 minutes (p < 0.0001), and activation time from 20.5 seconds to 10.6 seconds on average (p < 0.0001). In 2 patients with nerve injury, surgical repositioning of the electrode cuff became necessary. One patient showed a delayed wound healing, and in another patient the system had to be removed because of a wound infection. Marked improvement in mobility, social participation, and quality of life was confirmed by 89% to 96% of patients. CONCLUSIONS The ActiGait implantable drop foot stimulator improves gait speed, endurance, and quality of life in patients with stroke-related drop foot. Regarding gait speed, the ActiGait system appears to be advantageous compared with foot orthosis or surface stimulation devices. Randomized trials with more patients and longer observation periods are needed to prove the long-term benefit of this device.

  9. Measurement of an Evaporating Drop on a Reflective Substrate

    NASA Technical Reports Server (NTRS)

    Chao, David F.; Zhang, Nengli

    2004-01-01

    A figure depicts an apparatus that simultaneously records magnified ordinary top-view video images and laser shadowgraph video images of a sessile drop on a flat, horizontal substrate that can be opaque or translucent and is at least partially specularly reflective. The diameter, contact angle, and rate of evaporation of the drop as functions of time can be calculated from the apparent diameters of the drop in sequences of the images acquired at known time intervals, and the shadowgrams that contain flow patterns indicative of thermocapillary convection (if any) within the drop. These time-dependent parameters and flow patterns are important for understanding the physical processes involved in the spreading and evaporation of drops. The apparatus includes a source of white light and a laser (both omitted from the figure), which are used to form the ordinary image and the shadowgram, respectively. Charge-coupled-device (CCD) camera 1 (with zoom) acquires the ordinary video images, while CCD camera 2 acquires the shadowgrams. With respect to the portion of laser light specularly reflected from the substrate, the drop acts as a plano-convex lens, focusing the laser beam to a shadowgram on the projection screen in front of CCD camera 2. The equations for calculating the diameter, contact angle, and rate of evaporation of the drop are readily derived on the basis of Snell s law of refraction and the geometry of the optics.

  10. Sharp Interface Tracking in Rotating Microflows of Solvent Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glimm, James; Almeida, Valmor de; Jiao, Xiangmin

    2013-01-08

    The objective of this project is to develop a specialized sharp interface tracking simulation capability for predicting interaction of micron-sized drops and bubbles in rotating flows relevant to optimized design of contactor devices used in solvent extraction processes of spent nuclear fuel reprocessing. The primary outcomes of this project include the capability to resolve drops and bubbles micro-hydrodynamics in solvent extraction contactors, determining from first principles continuum fluid mechanics how micro-drops and bubbles interact with each other and the surrounding shearing fluid for realistic flows. In the near term, this effort will play a central role in providing parameters andmore » insight into the flow dynamics of models that average over coarser scales, say at the millimeter unit length. In the longer term, it will prove to be the platform to conduct full-device, detailed simulations as parallel computing power reaches the exaflop level. The team will develop an accurate simulation tool for flows containing interacting droplets and bubbles with sharp interfaces under conditions that mimic those found in realistic contactor operations. The main objective is to create an off-line simulation capability to model drop and bubble interactions in a domain representative of the averaged length scale. The technical approach is to combine robust interface tracking software, subgrid modeling, validation quality experiments, powerful computational hardware, and a team with simulation modeling, physical modeling and technology integration experience. Simulations will then fully resolve the microflow of drops and bubbles at the microsecond time scale. This approach is computationally intensive but very accurate in treating important coupled physical phenomena in the vicinity of interfaces. The method makes it possible to resolve spatial scales smaller than the typical distance between bubbles and to model some non-equilibrium thermodynamic features such as finite critical tension in cavitating liquids« less

  11. The Deformation of Polydimethylsiloxane (PDMS) Microfluidic Channels Filled with Embedded Circular Obstacles under Certain Circumstances.

    PubMed

    Roh, Changhyun; Lee, Jaewoong; Kang, Chankyu

    2016-06-18

    Experimental investigations were conducted to determine the influence of polydimethylsiloxane (PDMS) microfluidic channels containing aligned circular obstacles (with diameters of 172 µm and 132 µm) on the flow velocity and pressure drop under steady-state flow conditions. A significant PDMS bulging was observed when the fluid flow initially contacted the obstacles, but this phenomenon decreased in the 1 mm length of the microfluidic channels when the flow reached a steady-state. This implies that a microfluidic device operating with steady-state flows does not provide fully reliable information, even though less PDMS bulging is observed compared to quasi steady-state flow. Numerical analysis of PDMS bulging using ANSYS Workbench showed a relatively good agreement with the measured data. To verify the influence of PDMS bulging on the pressure drop and flow velocity, theoretical analyses were performed and the results were compared with the experimental results. The measured flow velocity and pressure drop data relatively matched well with the classical prediction under certain circumstances. However, discrepancies were generated and became worse as the microfluidic devices were operated under the following conditions: (1) restricted geometry of the microfluidic channels (i.e., shallow channel height, large diameter of obstacles and a short microchannel length); (2) operation in quasi-steady state flow; (3) increasing flow rates; and (4) decreasing amount of curing agent in the PDMS mixture. Therefore, in order to obtain reliable data a microfluidic device must be operated under appropriate conditions.

  12. The Characteristics of User-Generated Passwords

    DTIC Science & Technology

    1990-03-01

    electronic keys), user interface tokens (pocket devices that can generate one-time passwords) and fixed password devices ( plastic cards that contain...APPENDIX B-7 DIFFREM DIFFICULTY REMfEIBERING by PASSCHAR PASSORD CARACTERISTICS PASSCHAR Pate I of 1 Count 1 Row Pet IALPHAVET NUMERIC ALPHANUM ASCII Cal Pet

  13. 33 CFR 159.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...

  14. 33 CFR 159.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...

  15. 33 CFR 159.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...

  16. Lithium and boron based semiconductors for thermal neutron counting

    NASA Astrophysics Data System (ADS)

    Kargar, Alireza; Tower, Joshua; Hong, Huicong; Cirignano, Leonard; Higgins, William; Shah, Kanai

    2011-09-01

    Thermal neutron detectors in planar configuration were fabricated from LiInSe2 and B2Se3 crystals grown at RMD Inc. All fabricated semiconductor devices were characterized for the current-voltage (I-V) characteristic and neutron counting measurement. Pulse height spectra were collected from 241AmBe (neutron source on all samples), as well as 137Cs and 60Co gamma ray sources. In this study, the resistivity of all crystals is reported and the collected pulse height spectra are presented for fabricated devices. Note that, the 241AmBe neutron source was custom designed with polyethylene around the source as the neutron moderator, mainly to thermalize the fast neutrons before reaching the detectors. Both LiInSe2 and B2Se3 devices showed response to thermal neutrons of the 241AmBe source.

  17. Precision Luminosity of LHC Proton-Proton Collisions at 13 TeV Using Hit Counting With TPX Pixel Devices

    NASA Astrophysics Data System (ADS)

    Sopczak, André; Ali, Babar; Asawatavonvanich, Thanawat; Begera, Jakub; Bergmann, Benedikt; Billoud, Thomas; Burian, Petr; Caicedo, Ivan; Caforio, Davide; Heijne, Erik; Janeček, Josef; Leroy, Claude; Mánek, Petr; Mochizuki, Kazuya; Mora, Yesid; Pacík, Josef; Papadatos, Costa; Platkevič, Michal; Polanský, Štěpán; Pospíšil, Stanislav; Suk, Michal; Svoboda, Zdeněk

    2017-03-01

    A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13-TeV proton-proton collisions in 2015. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. A van der Meer scan of the LHC beams was analyzed using bunch-integrated luminosity averages over the different bunch profiles for an approximate absolute luminosity normalization. It is demonstrated that the TPX network has the capability to measure the reduction of LHC luminosity with precision. Comparative studies were performed among four sensors (two sensors in each TPX device) and the relative short-term precision of the luminosity measurement was determined to be 0.1% for 10-s time intervals. The internal long-term time stability of the measurements was below 0.5% for the data-taking period.

  18. GT3X+ accelerometer, Yamax pedometer and SC-StepMX pedometer step count accuracy in community-dwelling older adults.

    PubMed

    Webber, Sandra C; Magill, Sheila M; Schafer, Jenessa L; Wilson, Kaylie C S

    2014-07-01

    The purpose was to compare step count accuracy of an accelerometer (ActiGraph GT3X+), a mechanical pedometer (Yamax SW200), and a piezoelectric pedometer (SC-StepMX). Older adults (n = 13 with walking aids, n = 22 without; M = 81.5 years old, SD = 5.0) walked 100 m wearing the devices. Device-detected steps were compared with manually counted steps. We found no significant differences among monitors for those who walked without aids (p = .063). However, individuals who used walking aids exhibited slower gait speeds (M = 0.83 m/s, SD = 0.2) than non-walking aid users (M = 1.21 m/s, SD = 0.2, p < .001), and for them the SC-StepMX demonstrated a significantly lower percentage of error (Mdn = 1.0, interquartile range [IQR] = 0.5-2.0) than the other devices (Yamax SW200, Mdn = 68.9, IQR = 35.9-89.3; left GT3X+, Mdn = 52.0, IQR = 37.1-58.9; right GT3X+, Mdn = 51.0, IQR = 32.3-66.5; p < .05). These results support using a piezoelectric pedometer for measuring steps in older adults who use walking aids and who walk slowly.

  19. Turning Vanes in Exhaust Duct Flow: Study for Energy Efficiency, Optimization and Pressure Drop Mitigation

    DTIC Science & Technology

    2014-09-01

    bend of ninety degrees and the application toward waste heat recovery devices. CFD models were implemented in ANSYS / CFX to handle flow in both...devices. CFD models were implemented in ANSYS / CFX to handle flow in both laminar and turbulent regimes. Applying the principles from the Reynolds... ANSYS / CFX SET-UP ....................................................................................23  C.  EVALUATION OF VALIDATION RESULTS

  20. Posture And Dorsal Shape At A Sitted Workstation

    NASA Astrophysics Data System (ADS)

    Lepoutre, F. X.; Cloup, P.; Guerra, T. M.

    1986-07-01

    The ergonomic analysis of a control or a supervision workstation for a vehicle or a process, necessitates to take into account the biomecanical visuo-postural system. The measurements, which are necessary to do, must give informations about the spatial direction of the limbs, the dorsal shape, eventually the eyes direction, and the postural evolution during the working time. More, the smallness of the work station, the backrest and sometime a vibratory environment made use specific, strong and small devices wich do not disturb the operator. The measurement system which we propose is made of an optical device. This system is studied in relation with the french "Institute de Recherche pour les Transports" for an ergonomic analysis of a truck cabin. The optical device consists on placing on the body of the driver on particular places materializing specially members and trunck joint points, some drops which reflect the infra-red raies coming from a specific light. Several cameras whose relative positions depend on the experiment site, transmit video signals to the associated treatment systems which extract the coordinates (Xi, Yi) of each drop in the observation scope of any camera. By regrouping the informations obtained from every view, it is possible to obtain the spatial drop position and then to restore the individual's posture in three dimensions. Therefore, this device doesn't enable us, in consideration of the backrest, to analyse the dorsal posture, which is important with regard to dorsal pains frequency. For that reason, we complete the measurements by using a "curvometer". This device consists of a flexible stick fixed upon the individual back with elastic belts, whose distorsions (curvature in m-1) are measured, in the individual's sagittal plane, with 4 strain gauges pairs; located approximately at the level of vertebra D1, D6, D10 and L3. A fifth measurement, concerning the inclination (in degree) of the lower part of the stick, makes it is possible to represent at any time the dorsal shape in the space. Some examples of real postures, measured by these complementary electromecanic and video devices, will be presented.

  1. The long-term performance of electrically charged filters in a ventilation system.

    PubMed

    Raynor, Peter C; Chae, Soo Jae

    2004-07-01

    The efficiency and pressure drop of filters made from polyolefin fibers carrying electrical charges were compared with efficiency and pressure drop for filters made from uncharged glass fibers to determine if the efficiency of the charged filters changed with use. Thirty glass fiber filters and 30 polyolefin fiber filters were placed in different, but nearly identical, air-handling units that supplied outside air to a large building. Using two kinds of real-time aerosol counting and sizing instruments, the efficiency of both sets of filters was measured repeatedly for more than 19 weeks while the air-handling units operated almost continuously. Pressure drop was recorded by the ventilation system's computer control. Measurements showed that the efficiency of the glass fiber filters remained almost constant with time. However, the charged polyolefin fiber filters exhibited large efficiency reductions with time before the efficiency began to increase again toward the end of the test. For particles 0.6 microm in diameter, the efficiency of the polyolefin fiber filters declined from 85% to 45% after 11 weeks before recovering to 65% at the end of the test. The pressure drops of the glass fiber filters increased by about 0.40 in. H2O, whereas the pressure drop of the polyolefin fiber filters increased by only 0.28 in. H2O. The results indicate that dust loading reduces the effectiveness of electrical charges on filter fibers. Copyright 2004 JOEH, LLC

  2. Platelet-TLR7 mediates host survival and platelet count during viral infection in the absence of platelet-dependent thrombosis

    PubMed Central

    Koupenova, Milka; Vitseva, Olga; MacKay, Christopher R.; Beaulieu, Lea M.; Benjamin, Emelia J.; Mick, Eric; Kurt-Jones, Evelyn A.; Ravid, Katya

    2014-01-01

    Viral infections have been associated with reduced platelet counts, the biological significance of which has remained elusive. Here, we show that infection with encephalomyocarditis virus (EMCV) rapidly reduces platelet count, and this response is attributed to platelet Toll-like receptor 7 (TLR7). Platelet-TLR7 stimulation mediates formation of large platelet-neutrophil aggregates, both in mouse and human blood. Intriguingly, this process results in internalization of platelet CD41-fragments by neutrophils, as assessed biochemically and visualized by microscopy, with no influence on platelet prothrombotic properties. The mechanism includes TLR7-mediated platelet granule release, translocation of P-selectin to the cell surface, and a consequent increase in platelet-neutrophil adhesion. Viral infection of platelet-depleted mice also led to increased mortality. Transfusion of wild-type, TLR7-expressing platelets into TLR7-deficient mice caused a drop in platelet count and increased survival post EMCV infection. Thus, this study identifies a new link between platelets and their response to single-stranded RNA viruses that involves activation of TLR7. Finally, platelet-TLR7 stimulation is independent of thrombosis and has implications to the host immune response and survival. PMID:24755410

  3. Effectiveness evaluation of several cattle anthelmintics via the fecal egg count reduction test.

    PubMed

    Yazwinski, T A; Tucker, C A; Hornsby, J A; Powell, J G; Reynolds, J L; Johnson, Z B; Lindsey, W; Silver, T K

    2009-07-01

    Utilizing groups of cograzed, naturally infected beef-type heifers, three fecal egg count reduction tests were conducted in the later months of 2007 at the University of Arkansas. Each test was 28 days in length consisting of individual animal fecal nematode egg counts and coprocultures. Both original and generic ivermectin injectable formulations were used in two of the tests at 0.2 mg/kg BW, with FECR percentages never exceeding 90% in either test. Oral fenbendazole was evaluated at 5 and 10 mg/kg BW, with FECR%'s exceeding 90% on all occasions, but with a precipitous drop when recently treated animals were treated at the lower dose. Evaluated in one test, injectable moxidectin given at 0.2 mg/kg BW resulted in egg count reductions of 96-92% (days 7 to 28). Also evaluated in one test, albendazole delivered orally at 10 mg/kg BW was 98% and 97% effective at 17 and 28 days post-treatment. For all tests, coprocultures conducted post-treatment contained only Cooperia spp. larvae (benzimidazole use), relatively unmodified percentages of Cooperia spp. and Haemonchus spp. larvae (ivermectin use), and primarily Cooperia spp. larvae with a small percentage of Haemonchus spp. larvae (moxidectin use).

  4. Architecture and data processing alternatives for the TSE computer. Volume 3: Execution of a parallel counting algorithm using array logic (Tse) devices

    NASA Technical Reports Server (NTRS)

    Metcalfe, A. G.; Bodenheimer, R. E.

    1976-01-01

    A parallel algorithm for counting the number of logic-l elements in a binary array or image developed during preliminary investigation of the Tse concept is described. The counting algorithm is implemented using a basic combinational structure. Modifications which improve the efficiency of the basic structure are also presented. A programmable Tse computer structure is proposed, along with a hardware control unit, Tse instruction set, and software program for execution of the counting algorithm. Finally, a comparison is made between the different structures in terms of their more important characteristics.

  5. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    PubMed

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  6. Accurate high-speed liquid handling of very small biological samples.

    PubMed

    Schober, A; Günther, R; Schwienhorst, A; Döring, M; Lindemann, B F

    1993-08-01

    Molecular biology techniques require the accurate pipetting of buffers and solutions with volumes in the microliter range. Traditionally, hand-held pipetting devices are used to fulfill these requirements, but many laboratories have also introduced robotic workstations for the handling of liquids. Piston-operated pumps are commonly used in manually as well as automatically operated pipettors. These devices cannot meet the demands for extremely accurate pipetting of very small volumes at the high speed that would be necessary for certain applications (e.g., in sequencing projects with high throughput). In this paper we describe a technique for the accurate microdispensation of biochemically relevant solutions and suspensions with the aid of a piezoelectric transducer. It is suitable for liquids of a viscosity between 0.5 and 500 milliPascals. The obtainable drop sizes range from 5 picoliters to a few nanoliters with up to 10,000 drops per second. Liquids can be dispensed in single or accumulated drops to handle a wide volume range. The system proved to be excellently suitable for the handling of biological samples. It did not show any detectable negative impact on the biological function of dissolved or suspended molecules or particles.

  7. Harvesting energy from low-frequency excitations through alternate contacts between water and two dielectric materials.

    PubMed

    Yu, Jian; Ma, Enze; Ma, Tianwei

    2017-12-07

    Recent studies have demonstrated the benefits of water-dielectric interfaces in electrostatic energy harvesting. Most efforts have been focused on extracting the kinetic energy from the motions of water drops on hydrophobic surfaces, and thus, the resulting schemes inherently prefer cases where the water drops move at a high speed, or vibrate at a high frequency. Here we report a method for directly harvesting ambient mechanical energy as electric potential energy through water droplets by making alternate contacts with CYTOP and PTFE thin films. Because CYTOP and PTFE acquire significantly different surface charge densities during contact with water, such a difference can be utilized to effectively generate electricity. We demonstrate this concept using prototype devices fabricated on silicon substrates with a simple procedure. In the experiments conducted, a water drop of 400 μL alone could generate a peak open-circuit voltage of 42 V under a 0.25 Hz vibration. Under a 2.5 Hz vibration, the peak open-circuit voltage reached 115 V under an external bias of 8 V. The demonstrated efficiency is orders of magnitude higher than those of existing devices of similar dimensions.

  8. Dual curved photonic crystal ring resonator based channel drop filter using two-dimensional photonic crystal structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chhipa, Mayur Kumar, E-mail: mayurchhipa1@gmail.com; Dusad, Lalit Kumar

    In this paper channel drop filter (CDF) is designed using dual curved photonic crystal ring resonator (PCRR). The photonic band gap (PBG) is calculated by plane wave expansion (PWE) method and the photonic crystal (PhC) based on two dimensional (2D) square lattice periodic arrays of silicon (Si) rods in air structure have been investigated using finite difference time domain (FDTD) method. The number of rods in Z and X directions is 21 and 20 respectively with lattice constant 0.540 nm and rod radius r = 0.1 µm. The channel drop filter has been optimized for telecommunication wavelengths λ = 1.591 µm with refractivemore » indices 3.533. In the designed structure further analysis is also done by changing whole rods refractive index and it has been observed that this filter may be used for filtering several other channels also. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.« less

  9. Correlation of current drop, filling gas pressure, and ion beam emission in a low energy Mather-type plasma focus device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behbahani, R. A.; Aghamir, F. M.

    The behavior of current drop and its correlation with ion beam emission during the radial phase of a high inductance low energy Mather type plasma focus device have been studied. The study includes two ranges of filling gas pressure, namely the low range of 0.2-0.8 mbar and the high range of 0.8-1.5 mbar. Two different current simulation processes were performed to aid the interpretation of the experimental results. Within the low range of operating pressure, an acceptable match between the computed and experimental current signals was achieved when the effects of anomalous resistances were contemplated. While in the high rangemore » of pressure, the computed and experimental current traces were in line even without considering the effects of anomalous resistances. The analysis shows that by decreasing the filling gas pressure the effects of instabilities are intensified. The computed and experimental current traces, along with ion beam signals gathered from a faraday cup, show that there is a strong correlation between the intensity of ion beam and its duration with the current drop during the radial phase.« less

  10. PULSE COUNTER

    DOEpatents

    Trumbo, D.E.

    1959-02-10

    A transistorized pulse-counting circuit adapted for use with nuclear radiation detecting detecting devices to provide a small, light weight portable counter is reported. The small size and low power requirements of the transistor are of particular value in this instance. The circuit provides an adjustable count scale with a single transistor which is triggered by the accumulated charge on a storage capacitor.

  11. Electronic strain-level counter

    NASA Technical Reports Server (NTRS)

    Pitts, F. L.; Spencer, J. L. (Inventor)

    1973-01-01

    An electronic strain level counter for obtaining structural strain data on in-flight aircraft is described. The device counts the number of times the strain at a point on an aircraft structural member exceeds each of several preset levels. A dead band is provided at each level to prohibit the counting of small strain variations around a given preset level.

  12. The Green Ocean: Precipitation Insights from the GoAmazon2014/5 Experiment

    DOE PAGES

    Wang, Die; Giangrande, Scott E.; Bartholomew, Mary Jane; ...

    2018-02-07

    This study summarizes the precipitation properties collected during the GoAmazon2014/5 campaign near Manaus in central Amazonia, Brazil. Precipitation breakdowns, summary radar rainfall relationships and self-consistency concepts from a coupled disdrometer and radar wind profiler measurements are presented. The properties of Amazon cumulus and associated stratiform precipitation are discussed, including segregations according to seasonal (Wet/Dry regime) variability, cloud echo-top height and possible aerosol influences on the apparent oceanic characteristics of the precipitation drop size distributions. Overall, we observe that the Amazon precipitation straddles behaviors found during previous U.S. Department of Energy Atmospheric Radiation Measurements program (ARM) tropical deployments, with distributions favoringmore » higher concentrations of smaller drops than ARM continental examples. Oceanic type precipitation characteristics are predominantly observed during the Amazon Wet seasons. Finally, an exploration of the controls on Wet season precipitation properties reveals that wind direction, as compared with other standard radiosonde thermodynamic parameters or aerosol count/regime classifications performed at the ARM site, provides a good indicator for those Wet season Amazon events having an oceanic character for their precipitation drop size distributions.« less

  13. The Green Ocean: Precipitation Insights from the GoAmazon2014/5 Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Die; Giangrande, Scott E.; Bartholomew, Mary Jane

    This study summarizes the precipitation properties collected during the GoAmazon2014/5 campaign near Manaus in central Amazonia, Brazil. Precipitation breakdowns, summary radar rainfall relationships and self-consistency concepts from a coupled disdrometer and radar wind profiler measurements are presented. The properties of Amazon cumulus and associated stratiform precipitation are discussed, including segregations according to seasonal (Wet/Dry regime) variability, cloud echo-top height and possible aerosol influences on the apparent oceanic characteristics of the precipitation drop size distributions. Overall, we observe that the Amazon precipitation straddles behaviors found during previous U.S. Department of Energy Atmospheric Radiation Measurements program (ARM) tropical deployments, with distributions favoringmore » higher concentrations of smaller drops than ARM continental examples. Oceanic type precipitation characteristics are predominantly observed during the Amazon Wet seasons. Finally, an exploration of the controls on Wet season precipitation properties reveals that wind direction, as compared with other standard radiosonde thermodynamic parameters or aerosol count/regime classifications performed at the ARM site, provides a good indicator for those Wet season Amazon events having an oceanic character for their precipitation drop size distributions.« less

  14. Monitoring of Dermanyssus gallinae in free-range poultry farms.

    PubMed

    Zenner, L; Bon, G; Chauve, C; Nemoz, C; Lubac, S

    2009-06-01

    Various methods for monitoring Dermanyssus gallinae infestations within free-range egg production units were compared. The study was carried out in five egg-producing free-range poultry buildings infested with D. gallinae. Each farm was divided into six zones (each zone including nest boxes, perches and duckboard) for placing two types of traps (corrugated cardboard and thick card traps) or examining dried droppings for presence of mites. Traps were removed 24 h later, placed into bags and mites were counted at the laboratory using binocular magnification. Droppings were also inspected by eye and mite numbers were estimated. All the methods used allowed us to detect mites although their efficacy differed. The number of mites collected was independent of the type of trap used. Examination of the droppings did not differentiate between buildings with differing mite populations. Placing traps in the nest boxes is a less reliable indicator than placing them on the perches. It appears that the most coherent method for evaluating the D. gallinae population within a free-range flock is to place thick card traps throughout the building, on perches favoured by birds.

  15. Net current control device. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fugate, D.; Cooper, J.H.

    1998-11-01

    Net currents generally result in elevated magnetic fields because the alternate paths are distant from the circuit conductors. Investigations have shown that one of the primary sources of power frequency magnetic fields in residential buildings is currents that return to their source via paths other than the neutral conductors. As part of EPRI`s Magnetic Field Shielding Project, ferromagnetic devices, called net current control (NCC) devices, were developed and tested for use in reducing net currents on electric power cables and the resulting magnetic fields. Applied to a residential service drop, an NCC device reduces net current by forcing current offmore » local non-utility ground paths, and back onto the neutral conductor. Circuit models and basic design equations for the NCC concept were developed, and proof-of-principles tests were carried out on an actual residence with cooperation from the local utility. After proving the basic concepts, three prototype NCC devices were built and tested on a simulated neighborhood power system. Additional prototypes were built for testing by interested EPRI utility members. Results have shown that the NCC prototypes installed on residential service drops reduce net currents to milliampere levels with compromising the safety of the ground system. Although the focus was on application to residential service cables, the NCC concept is applicable to single-phase and three-phase distribution systems as well.« less

  16. The 2006 Project Progress Report for 1987-099-00 Dworshak Kokanee Population and Entrainment Assessment (contract # 26850) is attached to project 2007-003-00, contract #31598. [POINTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-12-18

    During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less

  17. Dworshak Kokanee Population and Engrainment Assessment : 2006 Annual Report, March 1, 2006 - February 28, 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stark, Eric J.

    2008-12-18

    During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fishmore » counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less

  18. The 2005 Project Progress Report for 1987-099-00 Dworshak Kokanee Population and Entrainment Assessment (contract # 16791) is attached to project 1987-099-00, contract # 26850. [POINTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-12-18

    During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. We tested one set of nine strobe lights flashing at a rate of 360 flashes/min in front of turbine 3 while operating at higher discharges than previously tested. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On five nights between January 31 andmore » February 28, 2006, when no lights were present, fish counts near turbine 3 averaged eight fish and densities averaged 91 fish/ha. When strobe lights were turned on during five adjacent nights during the same period, mean counts dropped to four fish and densities dropped to 35 fish/ha. The decline in counts (49%) was not statistically significant (p = 0.182), but decline in densities (62%) was significant (p = 0.049). There appeared to be no tendency for fish to habituate to the lights during the night. Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of turbines operating at higher discharges, which would be sufficient to improve sportfish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2005. Estimated abundance of kokanee decreased from the 2004 population estimate. Based on hydroacoustic surveys, we estimated 3,011,626 kokanee (90% CI {+-} 15.2%) in Dworshak Reservoir, July 2005. This included 2,135,986 age-0 (90% CI {+-} 15.9%), 769,175 age-1 (90% CI {+-} 16.0%), and 107,465 age-2 (90% CI {+-} 15.2%). Poor survival of kokanee from age-1 to age-2 continued to keep age-2 densities below the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site split-beam hydroacoustics a minimum of two days per month for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were again found during nighttime periods and lowest during the day. Fish detection rates were low during high discharges throughout the spring and summer and highest during low discharges in September and November. High discharge during drawdowns for anadromous fish flows in July and August again resulted in low detection rates and susceptibility to entrainment. Index counts of spawning kokanee in four tributary streams totaled 12,742 fish. This data fits the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.« less

  19. Magnetorheological valve based actuator for improvement of passively controlled turbocharger system

    NASA Astrophysics Data System (ADS)

    Bahiuddin, I.; Mazlan, S. A.; Imaduddin, F.; Ubaidillah, Ichwan, B.

    2016-03-01

    Variable geometry turbochargers have been widely researched to fulfil the current engine stringent regulations. The passively controlled turbocharger (PCT) concept has been proposed to reduce energy consumption by utilizing the emission energy to move the actuator. However, it only covered a small range operating condition. Therefore, a magnetorheological(MR) Valve device, as typical smart material devices to enhance a passive device, is proposed to improve the PCT. Even though the benefits have been considered for the compactness and easiness to connect to an electrical system, the number of publications regarding the MR application within engine system is hard to be found. Therefore, this paper introduces a design of an MR Valve in a turbocharger. The main challenge is to make sure its capability to produce a sufficient total pressure drop. To overcome the challenge, its material properties, shape and pressure drop calculation has been analyzed to fulfil the requirement. Finally, to get a more understanding of actuator performance, the actuator response was simulated by treating the exhaust gas pressure as an input. It shows that the new MR actuator has a potential dynamic to improve the PCT controllability.

  20. Handheld Diagnostic Device Delivers Quick Medical Readings

    NASA Technical Reports Server (NTRS)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  1. Rotational microfluidic motor for on-chip microcentrifugation

    NASA Astrophysics Data System (ADS)

    Shilton, Richie J.; Glass, Nick R.; Chan, Peggy; Yeo, Leslie Y.; Friend, James R.

    2011-06-01

    We report on the design of a surface acoustic wave (SAW) driven fluid-coupled micromotor which runs at high rotational velocities. A pair of opposing SAWs generated on a lithium niobate substrate are each obliquely passed into either side of a fluid drop to drive rotation of the fluid, and the thin circular disk set on the drop. Using water for the drop, a 5 mm diameter disk was driven with rotation speeds and start-up torques up to 2250 rpm and 60 nN m, respectively. Most importantly for lab-on-a-chip applications, radial accelerations of 172 m/s2 was obtained, presenting possibilities for microcentrifugation, flow sequencing, assays, and cell culturing in truly microscale lab-on-a-chip devices.

  2. A novel conduit-based coaptation device for primary nerve repair.

    PubMed

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  3. Design of distributed JT (Joule-Thomson) effect heat exchanger for superfluid 2 K cooling device

    NASA Astrophysics Data System (ADS)

    Jeong, S.; Park, C.; Kim, K.

    2018-03-01

    Superfluid at 2 K or below is readily obtained from liquid helium at 4.2 K by reducing its vapour pressure. For better cooling performance, however, the cold energy of vaporized helium at 2 K chamber can be effectively utilized in a recuperator which is specially designed in this paper for accomplishing so-called the distributed Joule-Thomson (JT) expansion effect. This paper describes the design methodology of distributed JT effect heat exchanger for 2 K JT cooling device. The newly developed heat exchanger allows continuous significant pressure drop at high-pressure part of the recuperative heat exchanger by using a capillary tube. Being different from conventional recuperative heat exchangers, the efficient JT effect HX must consider the pressure drop effect as well as the heat transfer characteristic. The heat exchanger for the distributed JT effect actively utilizes continuous pressure loss at the hot stream of the heat exchanger by using an OD of 0.64 mm and an ID of 0.4 mm capillary tube. The analysis is performed by dividing the heat exchanger into the multiple sub-units of the heat exchange part and JT valve. For more accurate estimation of the pressure drop of spirally wound capillary tube, preliminary experiments are carried out to investigate the friction factor at high Reynolds number. By using the developed pressure drop correlation and the heat transfer correlation, the specification of the heat exchanger with distributed JT effect for 2 K JT refrigerator is determined.

  4. Before the Drop: Engineers Ready Supersonic Decelerator

    NASA Image and Video Library

    2014-05-21

    A saucer-shaped vehicle part of NASA Low-Density Supersonic Decelerator LDSD project designed to test interplanetary landing devices hangs on a tower in preparation for launch at the Pacific Missile Range Facility in Kauai, Hawaii.

  5. Pavement edge treatment.

    DOT National Transportation Integrated Search

    2013-01-01

    Four projects were built over two construction seasons using special devices attached to the paving machine that produces a 30 slope on the outside pavement edge instead of the near vertical drop-off common with conventional paving equipment. This ...

  6. [A comparison of three different needles used for spinal anesthesia in terms of squamous epithelial cell transport risk].

    PubMed

    Çiğdem, Ünal Kantekin; Sevinç, Şahin; Esef, Bolat; Süreyya, Öztürk; Muzaffer, Gencer; Akif, Demirel

    To investigate the differences in the number of squamous epithelial cells carried to the spinal canal by three different types of spinal needle tip of the same size. Patients were allocated into three groups (Group I, Group II, Group III). Spinal anesthesia was administered to Group I (n=50) using a 25G Quincke needle, to Group II (n=50) using a 25G pencil point spinal needle, and to Group III (n=50) using a non-cutting atraumatic needle with special bending. The first and third drops of cerebral spinal fluid (CSF) samples were taken from each patient and each drop was placed on a slide for cytological examination. Nucleated and non-nucleated squamous epithelial cells on the smear preparations were counted. There was statistically significant difference between the groups in respect to the number of squamous epithelial cells in the first drop (p<0.05). Group III had lower number of squamous epithelial cells in the first drop compared to that of Group I and Group II. Mean while Group I had higher number of squamous epithelial cells in the third drop compared to the other groups. The number of squamous epithelial cells in the first and third drops was statistically similar in each group respectively (p>0.05 for each group). In this study of different needle tips, it was seen that with atraumatic needle with special bending a significantly smaller number of cells were transported when compared to the Quincke tip needles, and with pencil point needles. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  7. North Carolina's Operation Medicine Drop: Results From One of the Nation's Largest Drug Disposal Programs.

    PubMed

    Fleming, Eleanor; Proescholdbell, Scott; Sachdeva, Nidhi; Alexandridis, Apostolos A; Margolis, Lewis; Ransdell, Kelly

    2016-01-01

    In 2013, a total of 1,085 North Carolina residents died due to unintentional poisoning; 91% of these deaths were attributed to medications or drugs (over-the-counter, prescription, or illicit). Proper disposal of unused, unneeded, and/or expired medications is an essential part of preventing these unintentional deaths, as well as averting the other adverse consequences of these drugs on the environment and population health. Operation Medicine Drop is a medication take-back program coordinated by Safe Kids North Carolina, a county-level, coalition-based injury prevention organization. The Operation Medicine Drop program and event registration system were used to review and validate the number of events, the counties where the events were held, and the number of unit doses (pills) collected from March 2010 to June 2014. SAS version 9.4 was used to generate basic counts and frequencies of events and doses, and ArcGIS version 10.0 was used to create the map. From March 2010 to June 2014, Operation Medicine Drop held 1,395 events with 245 different participating law enforcement agencies in 91 counties in North Carolina, and it collected 69.6 million unit doses of medication. More than 60 local Safe Kids North Carolina community coalitions had participated as of June 2014. Every year, Operation Medicine Drop has witnessed increases in events, participating agencies, participating counties, and the number of doses collected. Operation Medicine Drop is an excellent example of a successful and ongoing collaboration to improve public health. Medication take-back programs may play an important role in preventing future overdose deaths in North Carolina. ©2016 by the North Carolina Institute of Medicine and The Duke Endowment. All rights reserved.

  8. Enhanced two phase flow in heat transfer systems

    DOEpatents

    Tegrotenhuis, Ward E; Humble, Paul H; Lavender, Curt A; Caldwell, Dustin D

    2013-12-03

    A family of structures and designs for use in devices such as heat exchangers so as to allow for enhanced performance in heat exchangers smaller and lighter weight than other existing devices. These structures provide flow paths for liquid and vapor and are generally open. In some embodiments of the invention, these structures can also provide secondary heat transfer as well. In an evaporate heat exchanger, the inclusion of these structures and devices enhance the heat transfer coefficient of the evaporation phase change process with comparable or lower pressure drop.

  9. Combination pipe-rupture mitigator and in-vessel core catcher. [LMFBR

    DOEpatents

    Tilbrook, R.W.; Markowski, F.J.

    1982-03-09

    A device is described which mitigates against the effects of a failed coolant loop in a nuclear reactor by restricting the outflow of coolant from the reactor through the failed loop and by retaining any particulated debris from a molten core which may result from coolant loss or other cause. The device reduces the reverse pressure drop through the failed loop by limiting the access of coolant in the reactor to the inlet of the failed loop. The device also spreads any particulated core debris over a large area to promote cooling.

  10. Combination pipe rupture mitigator and in-vessel core catcher

    DOEpatents

    Tilbrook, Roger W.; Markowski, Franz J.

    1983-01-01

    A device which mitigates against the effects of a failed coolant loop in a nuclear reactor by restricting the outflow of coolant from the reactor through the failed loop and by retaining any particulated debris from a molten core which may result from coolant loss or other cause. The device reduces the reverse pressure drop through the failed loop by limiting the access of coolant in the reactor to the inlet of the failed loop. The device also spreads any particulated core debris over a large area to promote cooling.

  11. New device architecture of a thermoelectric energy conversion for recovering low-quality heat

    NASA Astrophysics Data System (ADS)

    Kim, Hoon; Park, Sung-Geun; Jung, Buyoung; Hwang, Junphil; Kim, Woochul

    2014-03-01

    Low-quality heat is generally discarded for economic reasons; a low-cost energy conversion device considering price per watt, /W, is required to recover this waste heat. Thin-film based thermoelectric devices could be a superior alternative for this purpose, based on their low material consumption; however, power generated in conventional thermoelectric device architecture is negligible due to the small temperature drop across the thin film. To overcome this challenge, we propose new device architecture, and demonstrate approximately 60 Kelvin temperature differences using a thick polymer nanocomposite. The temperature differences were achieved by separating the thermal path from the electrical path; whereas in conventional device architecture, both electrical charges and thermal energy share same path. We also applied this device to harvest body heat and confirmed its usability as an energy conversion device for recovering low-quality heat.

  12. The 13th Aerospace Mechanisms Symposium

    NASA Technical Reports Server (NTRS)

    Bond, A. C.

    1979-01-01

    Technological areas covered include propulsion, motion compensation, instrument pointing and adjustment, centrifuge testing, bearing design, vehicle braking, and cargo handling. Devices for satellite, missile, and hypersonic-wind-tunnel applications; space shuttle mechanical and thermal protection systems; and techniques for building large space structures are described. In addition, a fluid drop injector device for a Spacelab experiment, a helical grip for cable cars, and applications of rare earth permanent magnets are discussed.

  13. Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

    NASA Astrophysics Data System (ADS)

    Papell, S. Stephen; Nyland, Ted W.; Saiyed, Naseem H.

    Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomas devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1 - X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

  14. Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

    NASA Technical Reports Server (NTRS)

    Papell, S. S.; Nyland, Ted W.; Saiyed, Naseem H.

    1992-01-01

    Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomson devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1-X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

  15. Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

    NASA Technical Reports Server (NTRS)

    Papell, S. Stephen; Nyland, Ted W.; Saiyed, Naseem H.

    1992-01-01

    Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomas devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1 - X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

  16. Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

    NASA Astrophysics Data System (ADS)

    Papell, S. S.; Nyland, Ted W.; Saiyed, Naseem H.

    1992-07-01

    Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomson devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1-X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

  17. Comparing Global Positioning System (GPS) and Global Navigation Satellite System (GNSS) Measures of Team Sport Movements.

    PubMed

    Jackson, Benjamin M; Polglaze, Ted; Dawson, Brian; King, Trish; Peeling, Peter

    2018-02-21

    To compare data from conventional GPS and new GNSS-enabled tracking devices, and to examine the inter-unit reliability of GNSS devices. Inter-device differences between 10 Hz GPS and GNSS devices were examined during laps (n=40) of a simulated game circuit (SGC) and during elite hockey matches (n=21); GNSS inter-unit reliability was also examined during the SGC laps. Differences in distance values and measures in three velocity categories (low <3 m.s -1 ; moderate 3-5 m.s -1 ; high >5 m.s -1 ) and acceleration/deceleration counts (>1.46 m.s -2 and < -1.46 m.s -2 ) were examined using one-way ANOVA. Inter-unit GNSS reliability was examined using the coefficient of variation (CV) and intra-class correlation coefficient (ICC). Inter-device differences (P <0.05) were found for measures of peak deceleration, low-speed distance, % total distance at low speed, and deceleration count during the SGC, and for all measures except total distance and low-speed distance during hockey matches. Inter-unit (GNSS) differences (P <0.05) were not found. The CV was below 5% for total distance, average and peak speeds and distance and % total distance of low-speed running. The GNSS devices had a lower HDoP score than GPS devices in all conditions. These findings suggest that GNSS devices may be more sensitive than GPS in quantifying the physical demands of team sport movements, but further study into the accuracy of GNSS devices is required.

  18. Radiation-Resistant Photon-Counting Detector Package Providing Sub-ps Stability for Laser Time Transfer in Space

    NASA Technical Reports Server (NTRS)

    Prochzaka, Ivan; Kodat, Jan; Blazej, Josef; Sun, Xiaoli (Editor)

    2015-01-01

    We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.

  19. High Resolution Gamma Ray Spectroscopy at MHz Counting Rates With LaBr3 Scintillators for Fusion Plasma Applications

    NASA Astrophysics Data System (ADS)

    Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.

    2013-04-01

    High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.

  20. The CAOS camera platform: ushering in a paradigm change in extreme dynamic range imager design

    NASA Astrophysics Data System (ADS)

    Riza, Nabeel A.

    2017-02-01

    Multi-pixel imaging devices such as CCD, CMOS and Focal Plane Array (FPA) photo-sensors dominate the imaging world. These Photo-Detector Array (PDA) devices certainly have their merits including increasingly high pixel counts and shrinking pixel sizes, nevertheless, they are also being hampered by limitations in instantaneous dynamic range, inter-pixel crosstalk, quantum full well capacity, signal-to-noise ratio, sensitivity, spectral flexibility, and in some cases, imager response time. Recently invented is the Coded Access Optical Sensor (CAOS) Camera platform that works in unison with current Photo-Detector Array (PDA) technology to counter fundamental limitations of PDA-based imagers while providing high enough imaging spatial resolution and pixel counts. Using for example the Texas Instruments (TI) Digital Micromirror Device (DMD) to engineer the CAOS camera platform, ushered in is a paradigm change in advanced imager design, particularly for extreme dynamic range applications.

  1. An Effectiveness Evaluation Between Manual and Automated Readability Counting Techniques. CNETS Report 5-75.

    ERIC Educational Resources Information Center

    Bunde, Gary R.

    A statistical comparison was made between two automated devices which were used to count data points (words, sentences, and syllables) needed in the Flesch Reading Ease Score to determine the reading grade level of written material. Determination of grade level of all Rate Training Manuals and Non-Resident Career Courses had been requested by the…

  2. Note: Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpert, B. K.; Horansky, R. D.; Bennett, D. A.

    Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operationmore » at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.« less

  3. Portable multiplicity counter

    DOEpatents

    Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM

    2009-09-01

    A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

  4. Microbial Check Valve for Shuttle

    NASA Technical Reports Server (NTRS)

    Colombo, G. V.; Putnam, D. F.; Sauer, R. L.

    1978-01-01

    The Microbial Check Valve (MCV) is a device developed for the Space Shuttle that prevents the transfer of viable microorganisms within water systems. The device is essentially a bed of resin material, impregnated with iodine, that kills microorganisms on contact. It prevents the cross-contamination of microorganisms from a nonpotable system into the potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the 'air gap' found in conventional one-gravity systems. Basic design data are presented including pressure drop, scaling factors, sizing criteria, and the results of challenging the device with suspensions of seven microorganisms including aerobes, anaerobes and spore formers.

  5. Pressure Reducer for Coal Gasifiers

    NASA Technical Reports Server (NTRS)

    Kendall, James M., Sr.

    1983-01-01

    Quasi-porous-plug pressure reducer is designed for gases containing abrasive particles. Gas used to generate high pressure steam to drive electric power generators. In giving up heat to steam, gas drops in temperature. Device used for coal gasification plants.

  6. A PDMS-Based Microfluidic Hanging Drop Chip for Embryoid Body Formation.

    PubMed

    Wu, Huei-Wen; Hsiao, Yi-Hsing; Chen, Chih-Chen; Yet, Shaw-Fang; Hsu, Chia-Hsien

    2016-07-06

    The conventional hanging drop technique is the most widely used method for embryoid body (EB) formation. However, this method is labor intensive and limited by the difficulty in exchanging the medium. Here, we report a microfluidic chip-based approach for high-throughput formation of EBs. The device consists of microfluidic channels with 6 × 12 opening wells in PDMS supported by a glass substrate. The PDMS channels were fabricated by replicating polydimethyl-siloxane (PDMS) from SU-8 mold. The droplet formation in the chip was tested with different hydrostatic pressures to obtain optimal operation pressures for the wells with 1000 μm diameter openings. The droplets formed at the opening wells were used to culture mouse embryonic stem cells which could subsequently developed into EBs in the hanging droplets. This device also allows for medium exchange of the hanging droplets making it possible to perform immunochemistry staining and characterize EBs on chip.

  7. Ultralow-voltage-drop GaN/InGaN/GaN tunnel junctions with 12% indium content

    NASA Astrophysics Data System (ADS)

    Akyol, Fatih; Zhang, Yuewei; Krishnamoorthy, Sriram; Rajan, Siddharth

    2017-12-01

    We report a combination of highly doped layers and polarization engineering that achieves highly efficient blue-transparent GaN/InGaN/GaN tunnel junctions (In content = 12%). NPN diode structures with a low voltage drop of 4.04 V at 5 kA/cm2 and a differential resistance of 6.51 × 10-5 Ω·cm2 at 3 kA/cm2 were obtained. The tunnel junction design with n++-GaN (Si: 5 × 1020 cm-3)/3 nm p++-In0.12Ga0.88N (Mg: 1.5 × 1020 cm-3)/p++-GaN (Mg: 5 × 1020 cm-3) showed the best device performance. Device simulations agree well with the experimentally determined optimal design. The combination of low In composition and high doping can facilitate lower tunneling resistance for blue-transparent light-emitting diodes.

  8. An acoustical bubble counter for superheated drop detectors.

    PubMed

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  9. Nanoscale electron transport at the surface of a topological insulator.

    PubMed

    Bauer, Sebastian; Bobisch, Christian A

    2016-04-21

    The use of three-dimensional topological insulators for disruptive technologies critically depends on the dissipationless transport of electrons at the surface, because of the suppression of backscattering at defects. However, in real devices, defects are unavoidable and scattering at angles other than 180° is allowed for such materials. Until now, this has been studied indirectly by bulk measurements and by the analysis of the local density of states in close vicinity to defect sites. Here, we directly measure the nanoscale voltage drop caused by the scattering at step edges, which occurs if a lateral current flows along a three-dimensional topological insulator. The experiments were performed using scanning tunnelling potentiometry for thin Bi2Se3 films. So far, the observed voltage drops are small because of large contributions of the bulk to the electronic transport. However, for the use of ideal topological insulating thin films in devices, these contributions would play a significant role.

  10. Nanoscale electron transport at the surface of a topological insulator

    NASA Astrophysics Data System (ADS)

    Bauer, Sebastian; Bobisch, Christian A.

    2016-04-01

    The use of three-dimensional topological insulators for disruptive technologies critically depends on the dissipationless transport of electrons at the surface, because of the suppression of backscattering at defects. However, in real devices, defects are unavoidable and scattering at angles other than 180° is allowed for such materials. Until now, this has been studied indirectly by bulk measurements and by the analysis of the local density of states in close vicinity to defect sites. Here, we directly measure the nanoscale voltage drop caused by the scattering at step edges, which occurs if a lateral current flows along a three-dimensional topological insulator. The experiments were performed using scanning tunnelling potentiometry for thin Bi2Se3 films. So far, the observed voltage drops are small because of large contributions of the bulk to the electronic transport. However, for the use of ideal topological insulating thin films in devices, these contributions would play a significant role.

  11. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE PAGES

    Godfrey, B.; Anderson, T.; Breedon, E.; ...

    2018-03-26

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  12. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, B.; Anderson, T.; Breedon, E.

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  13. Skin contamination dosimeter

    DOEpatents

    Hamby, David M [Corvallis, OR; Farsoni, Abdollah T [Corvallis, OR; Cazalas, Edward [Corvallis, OR

    2011-06-21

    A technique and device provides absolute skin dosimetry in real time at multiple tissue depths simultaneously. The device uses a phoswich detector which has multiple scintillators embedded at different depths within a non-scintillating material. A digital pulse processor connected to the phoswich detector measures a differential distribution (dN/dH) of count rate N as function of pulse height H for signals from each of the multiple scintillators. A digital processor computes in real time from the differential count-rate distribution for each of multiple scintillators an estimate of an ionizing radiation dose delivered to each of multiple depths of skin tissue corresponding to the multiple scintillators embedded at multiple corresponding depths within the non-scintillating material.

  14. DIME Students Show Off their Lego(TM) Challenge Creation

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Two students show the Lego (TM) Challenge device they designed and built to operate in the portable drop tower demonstrator as part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  15. Synthesis of highly integrated optical network based on microdisk-resonator add-drop filters in silicon-on-insulator technology

    NASA Astrophysics Data System (ADS)

    Kaźmierczak, Andrzej; Dortu, Fabian; Giannone, Domenico; Bogaerts, Wim; Drouard, Emmanuel; Rojo-Romeo, Pedro; Gaffiot, Frederic

    2009-10-01

    We analyze a highly compact optical add-drop filter topology based on a pair of microdisk resonators and a bus waveguide intersection. The filter is further assessed on an integrated optical 4×4 network for optical on-chip communication. The proposed network structure, as compact as 50×50 μm, is fabricated in a CMOS-compatible process on a silicon-on-insulator (SOI) substrate. Finally, the experimental results demonstrate the proper operation of the fabricated devices.

  16. Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model

    PubMed Central

    Wilkinson, Holly N.; McBain, Andrew J.; Stephenson, Christian; Hardman, Matthew J.

    2016-01-01

    Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze using a wounded porcine skin biofilm model with standardized application parameters. Biofilm removal was determined using a surface viability assay, bacterial counts, histological assessment, and scanning electron microscopy (SEM). Results: Quantitative analysis revealed that monofilament debriding devices outperformed the standard gauze, resulting in up to 100-fold greater reduction in bacterial counts. Interestingly, histological and morphological analyses suggested that debridement not only removed bacteria, but also differentially disrupted the bacterially-derived extracellular polymeric substance. Finally, SEM of post-debridement monofilaments showed structural changes in attached bacteria, implying a negative impact on viability. Innovation: This is the first study to combine controlled and defined debridement application with a biologically relevant ex vivo biofilm model to directly compare monofilament debriding devices. Conclusion: These data support the use of monofilament debriding devices for the removal of established wound biofilms and suggest variable efficacy towards biofilms composed of different species of bacteria. PMID:27867752

  17. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting

    PubMed Central

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-01-01

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e− read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor. PMID:27070625

  18. Flow rate-pressure drop relation for deformable shallow microfluidic channels

    NASA Astrophysics Data System (ADS)

    Christov, Ivan C.; Cognet, Vincent; Shidhore, Tanmay C.; Stone, Howard A.

    2018-04-01

    Laminar flow in devices fabricated from soft materials causes deformation of the passage geometry, which affects the flow rate--pressure drop relation. For a given pressure drop, in channels with narrow rectangular cross-section, the flow rate varies as the cube of the channel height, so deformation can produce significant quantitative effects, including nonlinear dependence on the pressure drop [{Gervais, T., El-Ali, J., G\\"unther, A. \\& Jensen, K.\\ F.}\\ 2006 Flow-induced deformation of shallow microfluidic channels.\\ \\textit{Lab Chip} \\textbf{6}, 500--507]. Gervais et. al. proposed a successful model of the deformation-induced change in the flow rate by heuristically coupling a Hookean elastic response with the lubrication approximation for Stokes flow. However, their model contains a fitting parameter that must be found for each channel shape by performing an experiment. We present a perturbation approach for the flow rate--pressure drop relation in a shallow deformable microchannel using the theory of isotropic quasi-static plate bending and the Stokes equations under a lubrication approximation (specifically, the ratio of the channel's height to its width and of the channel's height to its length are both assumed small). Our result contains no free parameters and confirms Gervais et. al.'s observation that the flow rate is a quartic polynomial of the pressure drop. The derived flow rate--pressure drop relation compares favorably with experimental measurements.

  19. Forced-air warming design: evaluation of intake filtration, internal microbial buildup, and airborne-contamination emissions.

    PubMed

    Reed, Mike; Kimberger, Oliver; McGovern, Paul D; Albrecht, Mark C

    2013-08-01

    Forced-air warming devices are effective for the prevention of surgical hypothermia. However, these devices intake nonsterile floor-level air, and it is unknown whether they have adequate filtration measures to prevent the internal buildup or emission of microbial contaminants. We rated the intake filtration efficiency of a popular current-generation forced-air warming device (Bair Hugger model 750, Arizant Healthcare) using a monodisperse sodium chloride aerosol in the laboratory. We further sampled 23 forced-air warming devices (same model) in daily hospital use for internal microbial buildup and airborne-contamination emissions via swabbing and particle counting. Laboratory testing found the intake filter to be 63.8% efficient. Swabbing detected microorganisms within 100% of the forced-air warming blowers sampled, with isolates of coagulase-negative staphylococci, mold, and micrococci identified. Particle counting showed 96% of forced-air warming blowers to be emitting significant levels of internally generated airborne contaminants out of the hose end. These findings highlight the need for upgraded intake filtration, preferably high-efficiency particulate air filtration (99.97% efficient), on current-generation forced-air warming devices to reduce contamination buildup and emission risks.

  20. vitisFlower®: Development and Testing of a Novel Android-Smartphone Application for Assessing the Number of Grapevine Flowers per Inflorescence Using Artificial Vision Techniques.

    PubMed

    Aquino, Arturo; Millan, Borja; Gaston, Daniel; Diago, María-Paz; Tardaguila, Javier

    2015-08-28

    Grapevine flowering and fruit set greatly determine crop yield. This paper presents a new smartphone application for automatically counting, non-invasively and directly in the vineyard, the flower number in grapevine inflorescence photos by implementing artificial vision techniques. The application, called vitisFlower(®), firstly guides the user to appropriately take an inflorescence photo using the smartphone's camera. Then, by means of image analysis, the flowers in the image are detected and counted. vitisFlower(®) has been developed for Android devices and uses the OpenCV libraries to maximize computational efficiency. The application was tested on 140 inflorescence images of 11 grapevine varieties taken with two different devices. On average, more than 84% of flowers in the captures were found, with a precision exceeding 94%. Additionally, the application's efficiency on four different devices covering a wide range of the market's spectrum was also studied. The results of this benchmarking study showed significant differences among devices, although indicating that the application is efficiently usable even with low-range devices. vitisFlower is one of the first applications for viticulture that is currently freely available on Google Play.

  1. Immunoglobulin G levels during collection of large volume plasma for fractionation.

    PubMed

    Burkhardt, Thomas; Rothe, Remo; Moog, Rainer

    2017-06-01

    There is a need of comprehensive work dealing with the quality of plasma for fractionation with respect to the IgG content as today most plasma derivates are used to treat patients with immunodeficiencies and autoimmune disorders. Therefore, a prospective study was carried out to analyse IgG levels before plasmapheresis and every 200ml collected plasma. Fifty-four experienced plasmapheresis donors were recruited for subsequent 850ml plasmapheresis using the Aurora Plasmapheresis System. Donorś peripheral blood counts were analysed before and after plasmapheresis using an electronic counter. Total protein, IgG and citrate were measured turbidometrically before, during and after apheresis as well as in the plasma product. Furthermore, platelets, red and white blood cells were analysed as parameters of product quality. An average of 2751±247ml blood was processed in 47±6min. The collected plasma volume was 850±1mL and citrate consumption was 177±15mL. A continuous drop of donors' IgG level was observed during plasmapheresis. The drop was 13% of the IgG baseline value at 800mL collected plasma. Total protein, IgG and cell counts of the plasma product met current guidelines of plasma for fractionation. Donors' IgG levels during apheresis showed a steady decrease without compromising the quality of plasma product. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Daily low-dose subcutaneous interleukin-2 added to single- or dual-nucleoside therapy in HIV infection does not protect against CD4+ T-cell decline or improve other indices of immune function: results of a randomized controlled clinical trial (ACTG 248).

    PubMed

    Vogler, Mary A; Teppler, Hedy; Gelman, Rebecca; Valentine, Fred; Lederman, Michael M; Pomerantz, Roger J; Pollard, Richard B; Cherng, Deborah Weng; Gonzalez, Charles J; Squires, Kathleen E; Frank, Ian; Mildvan, Donna; Mahon, Laura F; Schock, Barbara

    2004-05-01

    Approaches to preserve or enhance immune function in HIV-1 infection are needed. To examine the ability of daily low-dose interleukin-2 (IL-2) in combination with antiretroviral therapy to preserve circulating CD4+ T-cell counts, the clinical safety and tolerability of this treatment, and safety with respect to changes in plasma HIV-1 RNA levels. Twenty-four-week, phase 2, multicenter, randomized, open-label trial conducted at 12 AIDS Clinical Trials Units between September 1995 and May 1997. A total of 115 HIV-infected persons with screening CD4+ T-cell counts between 300 and 700 cells/mm who were on stable single- or dual-nucleoside therapy for at least 2 months, 11% of whom were also on a protease inhibitor at study entry. Patients were randomly assigned to receive IL-2 at a dose of 1 million IU subcutaneously once daily plus continued anti-retroviral therapy (ART + IL-2, n = 57) vs. continued ART alone (ART alone, n = 58). IL-2 dose reductions were made for objective or subjective toxicities. All subjects randomly assigned to the IL-2 arm who interrupted ART were also required to discontinue IL-2 for the same period. The primary endpoint was a decrease in CD4 T-cell count from baseline; the safety analysis was based on change in plasma HIV RNA by bDNA; and clinical safety and tolerability were analyzed by standard clinical criteria. Of the patients with a baseline CD4 T-cell count recorded, 15 (27%) of 55 patients randomly assigned to ART alone had a drop of > or =25% in their CD4 T-cell count and 23 (41%) of 56 patients randomly assigned to ART + IL-2 had a drop of > or =25% in their CD4 T-cell count at some time over the 24 weeks of the study. This difference was not statistically significant. There was a statistically significant greater variance in CD4 T-cell counts in the IL-2-treated group. More patients in the IL-2 group had at least a 25% increase in CD4 T-cell counts over baseline (34 vs. 13%, P = 0.007). A comparison of grade 3 or worse toxicity showed no differences between the arms, but IL-2 was associated with significantly more grade 2 or worse general body symptoms, primarily discomfort and fatigue. There was no significant difference between the groups with regard to changes in plasma HIV RNA, lymphocyte proliferation, natural killer cell activity, skin test responses to recall antigens, or antibody responses to immunization. Plasma markers of immune activation all increased significantly in IL-2 recipients. In patients with baseline CD4 T-cell counts > or =300 cells/mm primarily treated with single- or dual-nucleoside ART, subcutaneously administered IL-2 at a dose of 1 million IU daily for up to 24 weeks had low toxicity but showed no consistent benefit in preventing decline in CD4 T-cell counts and minimal evidence of immunologic improvement vs. continued ART alone.

  3. Brain-computer interface controlled functional electrical stimulation device for foot drop due to stroke.

    PubMed

    Do, An H; Wang, Po T; King, Christine E; Schombs, Andrew; Cramer, Steven C; Nenadic, Zoran

    2012-01-01

    Gait impairment due to foot drop is a common outcome of stroke, and current physiotherapy provides only limited restoration of gait function. Gait function can also be aided by orthoses, but these devices may be cumbersome and their benefits disappear upon removal. Hence, new neuro-rehabilitative therapies are being sought to generate permanent improvements in motor function beyond those of conventional physiotherapies through positive neural plasticity processes. Here, the authors describe an electroencephalogram (EEG) based brain-computer interface (BCI) controlled functional electrical stimulation (FES) system that enabled a stroke subject with foot drop to re-establish foot dorsiflexion. To this end, a prediction model was generated from EEG data collected as the subject alternated between periods of idling and attempted foot dorsiflexion. This prediction model was then used to classify online EEG data into either "idling" or "dorsiflexion" states, and this information was subsequently used to control an FES device to elicit effective foot dorsiflexion. The performance of the system was assessed in online sessions, where the subject was prompted by a computer to alternate between periods of idling and dorsiflexion. The subject demonstrated purposeful operation of the BCI-FES system, with an average cross-correlation between instructional cues and BCI-FES response of 0.60 over 3 sessions. In addition, analysis of the prediction model indicated that non-classical brain areas were activated in the process, suggesting post-stroke cortical re-organization. In the future, these systems may be explored as a potential therapeutic tool that can help promote positive plasticity and neural repair in chronic stroke patients.

  4. A new clocking method for a charge coupled device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umezu, Rika; Kitamoto, Shunji, E-mail: kitamoto@rikkyo.ac.jp; Murakami, Hiroshi

    2014-07-15

    We propose and demonstrate a new clocking method for a charge-coupled device (CCD). When a CCD is used for a photon counting detector of X-rays, its weak point is a limitation of its counting rate, because high counting rate makes non-negligible pile-up of photons. In astronomical usage, this pile-up is especially severe for an observation of a bright point-like object. One typical idea to reduce the pile-up is a parallel sum (P-sum) mode. This mode completely loses one-dimensional information. Our new clocking method, panning mode, provides complementary properties between the normal mode and the P-sum mode. We performed a simplemore » simulation in order to investigate a pile-up probability and compared the simulated result and actual obtained event rates. Using this simulation and the experimental results, we compared the pile-up tolerance of various clocking modes including our new method and also compared their other characteristics.« less

  5. Image charge multi-role and function detectors

    NASA Astrophysics Data System (ADS)

    Milnes, James; Lapington, Jon S.; Jagutzki, Ottmar; Howorth, Jon

    2009-06-01

    The image charge technique used with microchannel plate imaging tubes provides several operational and practical benefits by serving to isolate the electronic image readout from the detector. The simple dielectric interface between detector and readout provides vacuum isolation and no vacuum electrical feed-throughs are required. Since the readout is mechanically separate from the detector, an image tube of generic design can be simply optimised for various applications by attaching it to different readout devices and electronics. We present imaging performance results using a single image tube with a variety of readout devices suited to differing applications: (a) A four electrode charge division tetra wedge anode, optimised for best spatial resolution in photon counting mode. (b) A cross delay line anode, enabling higher count rate, and the possibility of discriminating near co-incident events, and an event timing resolution of better than 1 ns. (c) A multi-anode readout connected, either to a multi-channel oscilloscope for analogue measurements of fast optical pulses, or alternately, to a multi-channel time correlated single photon counting (TCSPC) card.

  6. Effects of Bite Count Feedback from a Wearable Device and Goal Setting on Consumption in Young Adults.

    PubMed

    Jasper, Phillip W; James, Melva T; Hoover, Adam W; Muth, Eric R

    2016-11-01

    New technologies are emerging that may help individuals engage in healthier eating behaviors. One paradigm to test the efficacy of a technology is to determine its effect relative to environment cues that are known to cause individuals to overeat. The purpose of this work was to independently investigate two questions: How does the presence of a technology that provides bite count feedback alter eating behavior? and, How does the presence of a technology that provides bite count feedback paired with a goal alter eating behavior? Two studies investigated these research questions. The first study tested the effects of a large and small plate crossed with the presence or absence of a device that provided bite count feedback on intake. The second study tested the effects of a bite count goal with bite count feedback, again crossed with plate size, on intake. Both studies used a 2×2 between-subjects design. In the first study, 94 subjects (62 women aged 19.0±1.6 years with body mass index [BMI] 23.04±3.6) consumed lunch in a laboratory. The second study examined 99 subjects (56 women aged 18.5±1.5 years with BMI 22.73±2.70) under the same conditions. In both studies subjects consumed a single-course meal, using either a small or large plate. In the first study participants either wore or did not wear an automated bite counting device. In the second study all participants wore the bite counting device and were given either a low bite count goal (12 bites) or a high bite count goal (22 bites). Effect of plate size, feedback, and goal on consumption (grams) and number of bites taken were assessed using 2×2 analyses of variance. As adjunct measures, the effects of serving size, bite size (grams per bite), postmeal satiety, and satiety change were also assessed. In the first study there was a main effect of plate size on grams consumed and number of bites taken such that eating from a large plate led to greater consumption (P=0.001) and a greater number of bites (P=0.001). There was also a main effect of feedback on consumption and number of bites taken such that those who received feedback consumed less (P=0.011) and took fewer bites (P<0.001). In the second study there was a main effect of plate size on consumption such that those eating from a large plate consumed more (P=0.003) but did not take more bites. Further analysis revealed a main effect of goal on number of bites taken such that those who received the low goal took fewer bites (P<0.001) but did not consume less. Providing feedback on the number of bites taken from a wearable intake monitor can reduce overall intake during a single meal. Regarding the first research question, providing feedback significantly reduced intake in both plate size groups and reduced the overall number of bites taken. Regarding the second research question, participants were successful in eating to their goals. However, individuals in the low goal condition appeared to compensate for the restricted goal by taking larger bites, leading to comparable levels of consumption between the low and high goal groups. Hence, the interaction of technology with goals should be considered when introducing a health intervention. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  7. Radiation detectors and sources enhanced with micro/nanotechnology

    NASA Astrophysics Data System (ADS)

    Whitney, Chad Michael

    The ongoing threat of nuclear terrorism presents major challenges to maintaining national security. Currently, only a small percentage of the cargo containers that enter America are searched for fissionable bomb making materials. This work reports on a multi-channel radiation detection platform enabled with nanoparticles that is capable of detecting and discriminating all types of radiation emitted from fissionable bomb making materials. Typical Geiger counters are limited to detecting only beta and gamma radiation. The micro-Geiger counter reported here detects all species of radiation including beta particles, gamma/X-rays, alpha particles, and neutrons. The multi-species detecting micro-Geiger counter contains a hermetically sealed and electrically biased fill gas. Impinging radiation interacts with tailored nanoparticles to release secondary charged particles that ionize the fill gas. The ionized particles collect on respectively biased electrodes resulting in a characteristic electrical pulse. Pulse height spectroscopy and radiation energy binning techniques can then be used to analyze the pulses to determine the specific radiation isotope. The ideal voltage range of operation for energy discrimination was found to be in the proportional region at 1000VDC. In this region, specific pulse heights for different radiation species resulted. The amplification region strength which determines the device sensitivity to radiation energy can be tuned with the electrode separation distance. Considerable improvements in count rates were achieved by using the charge conversion nanoparticles with the highest cross sections for particular radiation species. The addition of tungsten nanoparticles to the microGeiger counter enabled the device to be four times more efficient at detecting low level beta particles with a dose rate of 3.2uR/hr (micro-Roentgen per hour) and just under three times more efficient than an off the shelf Geiger counter. The addition of lead nanoparticles enabled the gamma/X-ray microGeiger counter channel to be 28 times more efficient at detecting low level gamma rays with a dose rate of 10uR/hr when compared to a device without nanoparticles. The addition of 10B nanoparticles enabled the neutron microGeiger counter channel to be 17 times more efficient at detecting neutrons. The device achieved a neutron count rate of 9,866 counts per minute when compared to a BF3 tube which resulted in a count rate of 9,000 counts per minute. By using a novel micro-injection ceramic molding and low temperature (950°C) silver paste metallizing process, the batch fabrication of essentially disposable micro-devices can be achieved. This novel fabrication technique was then applied to a MEMS neutron gun and water spectroscopy device that also utilizes the high voltage/temperature insulating packaging.

  8. Drop-casted self-assembling graphene oxide membranes for scanning electron microscopy on wet and dense gaseous samples.

    PubMed

    Krueger, Mark; Berg, Shannon; Stone, D'Arcy; Strelcov, Evgheni; Dikin, Dmitriy A; Kim, Jaemyung; Cote, Laura J; Huang, Jiaxing; Kolmakov, Andrei

    2011-12-27

    Graphene oxide sheets dispersed in water and many other solvents can spontaneously assemble into a surface film covering an evaporating droplet due to their amphiphilicity. Thus, graphene oxide membranes with controllable thickness suspended over an orifice have been directly fabricated using a simple drop-cast approach. Mechanical properties and electron transparency tests of these membranes show their use as electron transparent, but molecularly impenetrable, windows for environmental electron microscopy in liquids and dense gaseous media. The foreseeable, broader application of this drop-cast window methodology is the creation of access spots for electron probes to study isolated microsamples in their natural, undisrupted state within the interior of prefabricated devices (such as microfluidic chips or sealed containers of biological, chemically reactive, toxic, or forensic materials).

  9. Segmented nanowires displaying locally controllable properties

    DOEpatents

    Sutter, Eli Anguelova; Sutter, Peter Werner

    2013-03-05

    Vapor-liquid-solid growth of nanowires is tailored to achieve complex one-dimensional material geometries using phase diagrams determined for nanoscale materials. Segmented one-dimensional nanowires having constant composition display locally variable electronic band structures that are determined by the diameter of the nanowires. The unique electrical and optical properties of the segmented nanowires are exploited to form electronic and optoelectronic devices. Using gold-germanium as a model system, in situ transmission electron microscopy establishes, for nanometer-sized Au--Ge alloy drops at the tips of Ge nanowires (NWs), the parts of the phase diagram that determine their temperature-dependent equilibrium composition. The nanoscale phase diagram is then used to determine the exchange of material between the NW and the drop. The phase diagram for the nanoscale drop deviates significantly from that of the bulk alloy.

  10. High Broadband Spectral Resolving Transition-Edge Sensors for High Count-Rate Astrophysical Applications

    NASA Technical Reports Server (NTRS)

    Smith, Stephen

    2011-01-01

    We are developing arrays of transition-edge sensor (TES) X-ray detectors optimized for high count-rate solar astronomy applications where characterizing the high velocity motions of X-ray jets in solar flares is of particular interest. These devices are fabricated on thick Si substrates and consist of 35x35micron^2 TESs with 4.5micron thick, 60micron pitch, electroplated absorbers. We have tested devices fabricated with different geometric stem contact areas with the TES and surrounding substrate area, which allows us to investigate the loss of athermal phonons to the substrate. Results show a correlation between the stem contact area and a non-Gaussian broadening in the spectral line shape consistent with athermal phonon loss. When the contact area is minimized we have obtained remarkable board-band spectral resolving capabilities of 1.3 plus or minus 0.leV at an energy of 1.5 keV, 1.6 plus or minus 0.1 eV at 5.9 keV and 2.0 plus or minus 0.1 eV at 8 keV. This, coupled with a capability of accommodating 100's of counts per second per pixel makes these devices an exciting prospect of future x-ray astronomy applications.

  11. Statistical modeling of dental unit water bacterial test kit performance.

    PubMed

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  12. Dynamic postural stability for double-leg drop landing.

    PubMed

    Niu, Wenxin; Zhang, Ming; Fan, Yubo; Zhao, Qinping

    2013-01-01

    Dynamic postural stability has been widely studied for single-leg landing, but seldom considered for double-leg landing. This study aimed to evaluate the dynamic postural stability and the influence mechanism of muscle activities during double-leg drop landing. Eight recreationally active males and eight recreationally active females participated in this study and dropped individually from three heights (0.32 m, 0.52 m, and 0.72 m). Ground reaction force was recorded to calculate the time to stabilisation. Electromyographic activities were recorded for selected lower-extremity muscles. A multivariate analysis of variance was carried out and no significant influence was found in time to stabilisation between genders or limb laterals (P > 0.05). With increasing drop height, time to stabilisation decreased significantly in two horizontal directions and the lower-extremity muscle activities were enhanced. Vertical time to stabilisation was not significantly influenced by drop height. Dynamic postural stability improved by neuromuscular change more than that required due to the increase of drop height. Double-leg landing on level ground is a stable movement, and the body would often be injured before dynamic postural stability is impaired. It is understandable to protect tissues from mechanical injuries by the sacrifice of certain dynamic postural stability in the design of protective devices or athlete training.

  13. Voltage Drop in a Ferroelectric Single Layer Capacitor by Retarded Domain Nucleation.

    PubMed

    Kim, Yu Jin; Park, Hyeon Woo; Hyun, Seung Dam; Kim, Han Joon; Kim, Keum Do; Lee, Young Hwan; Moon, Taehwan; Lee, Yong Bin; Park, Min Hyuk; Hwang, Cheol Seong

    2017-12-13

    Ferroelectric (FE) capacitor is a critical electric component in microelectronic devices. Among many of its intriguing properties, the recent finding of voltage drop (V-drop) across the FE capacitor while the positive charges flow in is especially eye-catching. This finding was claimed to be direct evidence that the FE capacitor is in negative capacitance (NC) state, which must be useful for (infinitely) high capacitance and ultralow voltage operation of field-effect transistors. Nonetheless, the NC state corresponds to the maximum energy state of the FE material, so it has been widely accepted in the community that the material alleviates that state by forming ferroelectric domains. This work reports a similar V-drop effect from the 150 nm thick epitaxial BaTiO 3 ferroelectric thin film, but the interpretation was completely disparate; the V-drop can be precisely simulated by the reverse domain nucleation and propagation of which charge effect cannot be fully compensated for by the supplied charge from the external charge source. The disappearance of the V-drop effect was also observed by repeated FE switching only up to 10 cycles, which can hardly be explained by the involvement of the NC effect. The retained reverse domain nuclei even after the subsequent poling can explain such behavior.

  14. Dream Chaser ALT-2 Free Flight

    NASA Image and Video Library

    2017-11-07

    A lift device was attached to Sierra Nevada Corp’s Dream Chaser for a helicopter to pick it up to drop for its successful approach and landing test at NASA’s Armstrong Flight Research Center in California on Nov. 11, 2017.

  15. 40 CFR 65.145 - Nonflare control devices used to control emissions from storage vessels or low-throughput...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  16. 40 CFR 65.145 - Nonflare control devices used to control emissions from storage vessels or low-throughput...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  17. 40 CFR 63.985 - Nonflare control devices used to control emissions from storage vessels and low throughput...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  18. 40 CFR 63.985 - Nonflare control devices used to control emissions from storage vessels and low throughput...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  19. 40 CFR 63.985 - Nonflare control devices used to control emissions from storage vessels and low throughput...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  20. 40 CFR 65.145 - Nonflare control devices used to control emissions from storage vessels or low-throughput...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  1. 40 CFR 63.985 - Nonflare control devices used to control emissions from storage vessels and low throughput...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  2. 40 CFR 65.145 - Nonflare control devices used to control emissions from storage vessels or low-throughput...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... inlet stream and, if applicable, the desorption schedule, the regeneration stream pressure or temperature, and the flow rate of the regeneration stream. For vacuum desorption, pressure drop shall be...

  3. CMV retinitis recurs after stopping treatment in virological and immunological failures of potent antiretroviral therapy.

    PubMed

    Torriani, F J; Freeman, W R; Macdonald, J C; Karavellas, M P; Durand, D M; Jeffrey, D D; Meylan, P R; Schrier, R D

    2000-01-28

    To determine predictors of clinical relapse of cytomegalovirus (CMV) end-organ disease in a cohort of 17 HIV-infected patients with healed and treated CMV retinitis (CMVR) who responded to HAART with an increase in CD4 cell counts to above 70 cells/mm3 and discontinued CMV maintenance therapy (MT). Seventeen patients were monitored for reactivation of retinitis. The CD4 cell counts, HIV RNA and peripheral blood mononuclear cell (PBMC) lymphoproliferative assays to CMV at 3 month intervals were compared between patients with and without reactivation of CMVR. Positive lymphoproliferative responses were defined as a stimulation index of 3 or greater. Five out of 17 (29%) patients experienced a recurrence of CMVR a mean of 14.5 months after stopping CMV MT and between 8 days and 10 months after CD4 cell counts fell below 50 cells/mm3. Median CD4 cell counts and plasma HIV RNA at reactivation were 37 cells/mm3 and 5.3 log10 copies/ml. Three patients recurred at a previously active site of the retina, one had contralateral CMVR, and one a recurrence of retinitis and pancreatitis simultaneously. Mean lymphoproliferative responses to CMV were 2.4 in patients with reactivation versus 21.0 stimulation index (SI) in patients without reactivation (P= 0.01). A model incorporating four variables (CD4 cell counts and HIV RNA at maintenance discontinuation, highest CD4 cell count, nadir HIV RNA and median lymphoproliferative responses) identified correctly 88% of patients with and without reactivation. CMV disease recurs after virological and immunological failure of HAART if CD4 cell counts drop below 50. In this situation, anti-CMV agents should be resumed before clinical reactivation ensues, because of the risk of contralateral retinal involvement and systemic disease.

  4. Interactions Forces and the Flow-Induced Coalescence of Drops and Bubbles

    NASA Technical Reports Server (NTRS)

    Leal, L. Gary; Israelachvili, J.

    2004-01-01

    In order to accomplish the proposed macroscale experimental goals, we designed and built a pair of miniaturized computer-controlled four-roll mills, similar but much smaller than the 4-roll mill that had been develop earlier in Prof. Leal's group for studies of drop deformation and breakup. This unique experimental facility allows for controlled experiments on the breakup and coalescence of very small drops in the size range of 20-200 micrometers in diameter for a wide variety of flows and under a wide range of flow conditions including time-dependent flows, etc. The small size of this device is necessary for coalescence studies, since coalescence occurs in viscous fluids at capillary numbers that are large enough to be experimentally accessible only for drops that are smaller than approximately 100_m in diameter. Using these miniaturized 4-roll mills, we have obtained the first quantitative data (so far as we are aware) on the flow-induced coalescence process.

  5. Predicting the Drop Performance of Solder Joints by Evaluating the Elastic Strain Energy from High-Speed Ball Pull Tests

    NASA Astrophysics Data System (ADS)

    You, Taehoon; Kim, Yunsung; Kim, Jina; Lee, Jaehong; Jung, Byungwook; Moon, Jungtak; Choe, Heeman

    2009-03-01

    Despite being expensive and time consuming, board-level drop testing has been widely used to assess the drop or impact resistance of the solder joints in handheld microelectronic devices, such as cellphones and personal digital assistants (PDAs). In this study, a new test method, which is much simpler and quicker, is proposed. The method involves evaluating the elastic strain energy and relating it to the impact resistance of the solder joint by considering the Young’s modulus of the bulk solder and the fracture stress of the solder joint during a ball pull test at high strain rates. The results show that solder joints can be ranked in order of descending elastic strain energy as follows: Sn-37Pb, Sn-1Ag-0.5Cu, Sn-3Ag-0.5Cu, and Sn-4Ag-0.5Cu. This order is consistent with the actual drop performances of the samples.

  6. Patient warming excess heat: the effects on orthopedic operating room ventilation performance.

    PubMed

    Belani, Kumar G; Albrecht, Mark; McGovern, Paul D; Reed, Mike; Nachtsheim, Christopher

    2013-08-01

    Patient warming has become a standard of care for the prevention of unintentional hypothermia based on benefits established in general surgery. However, these benefits may not fully translate to contamination-sensitive surgery (i.e., implants), because patient warming devices release excess heat that may disrupt the intended ceiling-to-floor ventilation airflows and expose the surgical site to added contamination. Therefore, we studied the effects of 2 popular patient warming technologies, forced air and conductive fabric, versus control conditions on ventilation performance in an orthopedic operating room with a mannequin draped for total knee replacement. Ventilation performance was assessed by releasing neutrally buoyant detergent bubbles ("bubbles") into the nonsterile region under the head-side of the anesthesia drape. We then tracked whether the excess heat from upper body patient warming mobilized the "bubbles" into the surgical site. Formally, a randomized replicated design assessed the effect of device (forced air, conductive fabric, control) and anesthesia drape height (low-drape, high-drape) on the number of bubbles photographed over the surgical site. The direct mass-flow exhaust from forced air warming generated hot air convection currents that mobilized bubbles over the anesthesia drape and into the surgical site, resulting in a significant increase in bubble counts for the factor of patient warming device (P < 0.001). Forced air had an average count of 132.5 versus 0.48 for conductive fabric (P = 0.003) and 0.01 for control conditions (P = 0.008) across both drape heights. Differences in average bubble counts across both drape heights were insignificant between conductive fabric and control conditions (P = 0.87). The factor of drape height had no significant effect (P = 0.94) on bubble counts. Excess heat from forced air warming resulted in the disruption of ventilation airflows over the surgical site, whereas conductive patient warming devices had no noticeable effect on ventilation airflows. These findings warrant future research into the effects of forced air warming excess heat on clinical outcomes during contamination-sensitive surgery.

  7. Comparison of irrigation solutions and devices in a contaminated musculoskeletal wound survival model.

    PubMed

    Owens, Brett D; White, Daniel W; Wenke, Joseph C

    2009-01-01

    There is much to learn about the effectiveness of different methods currently used for the irrigation of open wounds. The purpose of this study was to compare various approaches in a survival animal model. We used an established goat model involving the creation of a reproducible complex musculoskeletal wound followed by inoculation with Pseudomonas aeruginosa (lux) bacteria. This genetically altered luminescent bacterium provides the ability for quantitative analysis with a photon-counting camera system. For Study 1, wound irrigation was performed six hours after the injury and inoculation; the goats were assigned to four treatment groups: normal saline solution, bacitracin solution, castile soap, and benzalkonium chloride. All wounds received sharp débridement and irrigation with use of a pulsatile lavage device (19 psi). Images and photon counts were obtained prior to irrigation, after irrigation, and forty-eight hours after injury and inoculation. For Study 2, we used the same animal model and compared bulb syringe and pulsatile lavage irrigation with saline solution. In Study 1, the irrigation treatment lowered the bacterial counts in all treatment groups. The greatest reduction was seen with castile soap, which lowered the photon count to 13% of the pretreatment level. This was followed by benzalkonium chloride, bacitracin, and saline solution at 18%, 22%, and 29%, respectively. At forty-eight hours, imaging showed a rebound in bacterial counts in every group. The highest rebound was measured in the castile soap group, which rebounded to 120% of the pretreatment level. The benzalkonium chloride group experienced a rebound to 94% of the pretreatment level. These were followed by bacitracin solution (89%) and normal saline solution (68%). In Study 2, both treatment methods were effective in removing 75% of the bacteria initially. At forty-eight hours, the bacterial levels in the pulsed lavage group rebounded to 94% of the original levels (compared with 48% in the bulb syringe group). The difference in the mean photon count ratios at forty-eight hours was significant (p = 0.048). Approaches used to remove bacteria from wounds, such as irrigants other than saline solution or high-pressure devices, may not have the best clinical outcome.

  8. The validity and reliability of the my jump 2 app for measuring the reactive strength index and drop jump performance.

    PubMed

    Haynes, Tom; Bishop, Chris; Antrobus, Mark; Brazier, Jon

    2018-03-27

    This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). Fourteen male sport science students (age: 29.5 ± 9.9 years) performed three drop jumps from 20 cm and 40 cm (totalling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and BlandAltman plots. Near perfect agreement was seen between devices at 20 cm for RSI (ICC = 0.95) and contact time (ICC = 0.99) and at 40 cm for RSI (ICC = 0.98), jump height (ICC = 0.96) and contact time (ICC = 0.92); with very strong agreement seen at 20 cm for jump height (ICC = 0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r = 0.94; 40 cm; r = 0.97), jump height (20 cm: r = 0.80; 40 cm; r = 0.96) and contact time (20 cm = 0.96; 40 cm; r = 0.98). The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.

  9. Biological Profiles of Korean Atomic Bomb Survivors in Residence at Daegu and Kyungbuk, Republic of Korea

    PubMed Central

    Jhun, Hyung-Joon; Kim, Byoung-Gwon; Kim, Su-Young; Koo, Bon-Min; Kim, Jin-Kook

    2008-01-01

    In 1945, many Koreans, in addition to Japanese, were killed or injured by the atomic bombs dropped on Hiroshima and Nagasaki, Japan. This study compared the biological profiles of Korean atomic bomb survivors in residence at Daegu and Kyungbuk, Republic of Korea with those of a representative sample of Koreans obtained during a similar period. We evaluated anthropometric measurements, blood pressure, blood cell counts, blood chemistry, and urinalysis of survivors (n=414) and age- and sex-matched controls (n=414) recruited from the third Korea National Health and Nutrition Examination Survey conducted in 2005. Univariate analyses revealed significantly higher systolic blood pressure, white blood cell count, and serum total cholesterol, triglycerides, high-density lipoprotein-cholesterol, and aspartate aminotransferase levels (p<0.01) in the survivors. Conversely, hemoglobin concentration, hematocrit, red blood cell count, and the proportion of positive urine occult blood (p<0.01) were lower in the survivors. Our findings suggest that biological profiles of Korean atomic bomb survivors were adversely affected by radiation exposure. PMID:19119455

  10. High Count-Rate Study of Two TES X-Ray Microcalorimeters With Different Transition Temperatures

    NASA Technical Reports Server (NTRS)

    Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.; hide

    2017-01-01

    We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures T(sub c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T(sub c)(sup s) had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.eV at 6 keV from lower and higher T(sub c) devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the socalled event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96 Percent throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T(sub c) (faster) device, and 5.8 eV FWHM with 97 Percent throughput with the lower T(sub c) (slower) device at 722 Hz.

  11. ON THE PROGNOSTIC SIGNIFICANCE OF THE ERYTHROCYTE SEDIMENTATION RATE, THE LEUKOCYTE COUNT, THE HEMOGLOBIN VALUE, AND BODY WEIGHT IN IRRADIATED AND NONIRRADIATED CANCER PATIENTS (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hofmann, D.

    1962-06-01

    Changes in these parameters were followed in 672 women with genital carcinoma during and after radiotherapy to determine whether any of them could be used to predict the eventual success of the treatment. All of these parameters were found to be of prognostic value in the 394 patients with carcinoma of the uterine cervix of grades I, II, and III. Erythrocyte sedimentation rate (ESR) was initially elevated in these patients, and in those without recurrence, irradiation caused a prompt and progressive drop in ESR. It continued to rise after radiotherapy in those who later showed tumor recurrence. Similar changes inmore » leukocyte count were seen in this group, the counts falling and staying down after successful treatment or rising when the treatment failed. An inverse relation with respect to the hemoglobin level and body wt was seen, both values progressively increasing in cases later shown to be cured and falling in those which were not. These relations did not hold or were of less prognostic value in patients with carcinomas of the body of the uterus, ovary, or vulva. However, in general, a gradual continual fall in ESR and a rapid fall in leukocyte count were favorable signs following irradiation. (BBB)« less

  12. Cursor Control Device Test Battery

    NASA Technical Reports Server (NTRS)

    Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby

    2013-01-01

    The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not include all of the underlined characters, or includes non-underlined characters, it is recorded as an error. Task 6, Multi-size and Multi-distance Pointing, presents the participant with 24 consecutively numbered buttons of different sizes (63 to 163 pixels), and at different distances (60 to 80 pixels) from the Start button. The task is to click on the Start button, and then move directly to, and click on, each numbered target button in consecutive order. Clicks outside of the target area are errors. Task 7, Standard Interface Elements Task, involves interacting with standard interface elements as instructed in written procedures, including: drop-down menus, sliders, text boxes, radio buttons, and check boxes. Task completion time is recorded. In Task 8, a circular track is presented with a disc in it at the top. Track width and disc size are adjustable. The task is to move the disc with circular motion within the path without touching the boundaries of the track. Time and errors are recorded. Task 9 is a discrete task that allows evaluation of discrete cursor control devices that tab from target to target, such as a castle switch. The task is to follow a predefined path and to click on the yellow targets along the path.

  13. 2009 NJDOT FWD procedures manual.

    DOT National Transportation Integrated Search

    2009-01-01

    A falling weight deflectometer (FWD) is a device designed to simulate deflection of a pavement surface caused by a fast-moving truck. The FWD generates a load pulse by dropping a weight onto the pavement surface. This load pulse is transmitted to the...

  14. Monitoring the hatch time of individual chicken embryos.

    PubMed

    Romanini, C E B; Exadaktylos, V; Tong, Q; McGonnel, I; Demmers, T G M; Bergoug, H; Eterradossi, N; Roulston, N; Garain, P; Bahr, C; Berckmans, D

    2013-02-01

    This study investigated variations in eggshell temperature (T(egg)) during the hatching process of broiler eggs. Temperature sensors monitored embryo temperature by registering T(egg) every minute. Measurements carried out on a sample of 40 focal eggs revealed temperature drops between 2 to 6°C during the last 3 d of incubation. Video cameras recorded the hatching process and served as the gold standard reference for manually labeling the hatch times of chicks. Comparison between T(egg) drops and the hatch time of individuals revealed a time synchronization with 99% correlation coefficient and an absolute average time difference up to 25 min. Our findings suggest that attaching temperature sensors to eggshells is a precise tool for monitoring the hatch time of individual chicks. Individual hatch monitoring registers the biological age of chicks and facilitates an accurate and reliable means to count hatching results and manage the hatch window.

  15. Tunable thermal link

    DOEpatents

    Chang, Chih-Wei; Majumdar, Arunava; Zettl, Alexander K.

    2014-07-15

    Disclosed is a device whereby the thermal conductance of a multiwalled nanostructure such as a multiwalled carbon nanotube (MWCNT) can be controllably and reversibly tuned by sliding one or more outer shells with respect to the inner core. As one example, the thermal conductance of an MWCNT dropped to 15% of the original value after extending the length of the MWCNT by 190 nm. The thermal conductivity returned when the tube was contracted. The device may comprise numbers of multiwalled nanotubes or other graphitic layers connected to a heat source and a heat drain and various means for tuning the overall thermal conductance for applications in structure heat management, heat flow in nanoscale or microscale devices and thermal logic devices.

  16. Effects of Humidity and Temperature on Orange Dye-Based Organic Field Effect Transistors Fabricated at Different Gravity

    NASA Astrophysics Data System (ADS)

    Fatima, N.; Ahmed, M. M.; Karimov, Kh. S.

    2017-11-01

    This study reports the fabrication of organic field effect transistors (OFETs) using 3-[ethyl[4-[(4-nitrophenyl)azo]phenyl]amino]propanenitrile, usually known as Orange-Dye 25 (OD) and its composite with sugar. The study investigated the heat- and humidity-dependent electrical characteristics of the fabricated devices. Fabrication was carried out from the aqueous solution of the materials using different gravity conditions, i.e., at positive (normal) gravity (+1 g) and at negative gravity (-1 g). A thin layer (10-15 μm) of OD or OD:sugar was deposited by drop-casting on pre-fabricated drain and source silver (Ag) electrodes having 30 μm separation and 2 mm length followed by aluminum (Al) thermal evaporation to achieve a Schottky barrier. Devices fabricated using OD at -1 g were more sensitive in capacitance-temperature and impedance-humidity relationships than those fabricated at +1 g. Moreover, OFETs fabricated at -1 g using OD:sugar offered capacitance-temperature sensitivity much higher than the devices fabricated at +1 g. It has been observed that, in the drop-casting method, the properties of OFETs are dependent upon gravity as well as the solution composition employed for channel definition.

  17. 3-Dimensional numerical study of cooling performance of a heat sink with air-water flow through mini-channel

    NASA Astrophysics Data System (ADS)

    Majumder, Sambit; Majumder, Abhik; Bhaumik, Swapan

    2016-07-01

    The present microelectronics market demands devices with high power dissipation capabilities having enhanced cooling per unit area. The drive for miniaturizing the devices to even micro level dimensions is shooting up the applied heat flux on such devices, resulting in complexity in heat transfer and cooling management. In this paper, a method of CPU processor cooling is introduced where active and passive cooling techniques are incorporated simultaneously. A heat sink consisting of fins is designed, where water flows internally through the mini-channel fins and air flows externally. Three dimensional numerical simulations are performed for large set of Reynolds number in laminar region using finite volume method for both developing flows. The dimensions of mini-channel fins are varied for several aspect ratios such as 1, 1.33, 2 and 4. Constant temperature (T) boundary condition is applied at heat sink base. Channel fluid temperature, pressure drop are analyzed to obtain best cooling option in the present study. It has been observed that as the aspect ratio of the channel decreases Nusselt number decreases while pressure drop increases. However, Nusselt number increases with increase in Reynolds number.

  18. Intraocular pressure control of a novel glaucoma drainage device - in vitro and in vivo studies

    PubMed Central

    Cui, Li-Jun; Li, Di-Chen; Liu, Jian; Zhang, Lei; Xing, Yao

    2017-01-01

    AIM To evaluate the intraocular pressure (IOP) control of an artificial trabeculum drainage system (ATDS), a newly designed glaucoma drainage device, and postoperative complications in normal rabbit eyes. METHODS Pressure drops in air and fluid of 30 ATDS were measured after being connected to a closed manometric system. Twenty of them were then chosen and implanted randomly into the eyes of 20 rabbits. Postoperative slit-lamp, gonioscopic examination and IOP measurements were recorded periodically. Ultrasound biomicroscopy and B-scan ultrasonography were also used to observe the complications. Eyes were enucleated on day 60. RESULTS Pressure drops of 4.6-9.4 mm Hg were obtained at physiological aqueous flow rates in the tests in vitro. The average postoperative IOP of the experimental eyes (11.6-12.8 mm Hg) was lower than the controls significantly (P<0.05) at each time point. Complications of hemorrhage (n=1), cellulosic exudation (two cases) and local iris congestion (two cases) were observed. The lumina of the devices were devoid of obstructions in all specimens examined and a thin fibrous capsule was found around the endplate. CONCLUSION ATDS reduce IOP effectively. However, further studies on the structure are needed to reduce complications. PMID:28944192

  19. Integrated microfluidic system with simultaneous emulsion generation and concentration.

    PubMed

    Koppula, Karuna S; Fan, Rong; Veerapalli, Kartik R; Wan, Jiandi

    2016-03-15

    Because the size, size distribution, and concentration of emulsions play an important role in most of the applications, controlled emulsion generation and effective concentration are of great interest in fundamental and applied studies. While microfluidics has been demonstrated to be able to produce emulsion drops with controlled size, size distribution, and hierarchical structures, progress of controlled generation of concentrated emulsions is limited. Here, we present an effective microfluidic emulsion generation system integrated with an orifice structure to separate aqueous droplets from the continuous oil phase, resulting in concentrated emulsion drops in situ. Both experimental and simulation results show that the efficiency of separation is determined by a balance between pressure drop and droplet accumulation near the orifice. By manipulating this balance via changing flow rates and microfluidic geometry, we can achieve monodisperse droplets on chip that have a concentration as high as 80,000 drops per microliter (volume fraction of 66%). The present approach thus provides insights to the design of microfluidic device that can be used to concentrate emulsions (drops and bubbles), colloidal particles (drug delivery polymer particles), and biological particles (cells and bacteria) when volume fractions as high as 66% are necessary. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. A hydrodynamic mechanism for spontaneous formation of ordered drop arrays in confined shear flow

    NASA Astrophysics Data System (ADS)

    Singha, Sagnik; Zurita-Gotor, Mauricio; Loewenberg, Michael; Migler, Kalman; Blawzdziewicz, Jerzy

    2017-11-01

    It has been experimentally demonstrated that a drop monolayer driven by a confined shear flow in a Couette device can spontaneously arrange into a flow-oriented parallel chain microstructure. However, the hydrodynamic mechanism of this puzzling self-assembly phenomenon has so far eluded explanation. In a recent publication we suggested that the observed spontaneous drop ordering may arise from hydrodynamic interparticle interactions via a far-field quadrupolar Hele-Shaw flow associated with drop deformation. To verify this conjecture we have developed a simple numerical-simulation model that includes the far-field Hele-Shaw flow quadrupoles and a near-field short-range repulsion. Our simulations show that an initially disordered particle configuration self-organizes into a system of particle chains, similar to the experimentally observed drop-chain structures. The initial stage of chain formation is fast; subsequently, microstructural defects in a partially ordered system are removed by slow annealing, leading to an array of equally spaced parallel chains with a small number of defects. The microstructure evolution is analyzed using angular and spatial order parameters and correlation functions. Supported by NSF Grants No. CBET 1603627 and CBET 1603806.

  1. An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor

    NASA Astrophysics Data System (ADS)

    Staderini, Enrico Maria; Castellano, Alfredo

    1986-02-01

    An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2. On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation.

  2. In vivo challenging of polymyxins and levofloxacin eye drop against multidrug-resistant Pseudomonas aeruginosa keratitis.

    PubMed

    Tajima, Kazuki; Miyake, Taku; Koike, Naohito; Hattori, Takaaki; Kumakura, Shigeto; Yamaguchi, Tetsuo; Matsumoto, Tetsuya; Fujita, Koji; Kuroda, Masahiko; Ito, Norihiko; Goto, Hiroshi

    2014-06-01

    The purposes of this study were to establish a rabbit multidrug-resistant Pseudomonas aeruginosa (MDRP) keratitis model, and test the efficacy of levofloxacin, colistin methanesulfate (CL-M), colistin sulfate (CL-S) and polymyxin B (PL-B) against MDRP infection. In a rabbit eye, making a 2-mm circular corneal excision, and MDRP strain #601 or representative P. aeruginosa strain IID1210 were instilled into the corneal concavity. IID1210 was used to confirm this model developed P. aeruginosa keratitis. After MDRP keratitis developed, we treated the eyes with levofloxacin, CL-M, CL-S or PL-B eye drops. The infected eyes were evaluated by clinical score, histopathological examination and viable bacterial count (CFU). Rabbits developed MDRP keratitis reproducibly after instilled the bacteria into the corneal lesion. MDRP produced severe keratitis similarly with IID1210, as shown by slit lamp examination and clinical score. In MDRP keratitis models, clinical scores and viable bacterial counts were significantly lower in levofloxacin- and CL-M-treated groups compared with PBS-treated group, but the magnitudes of reduction were not remarkable. However, clinical scores were dramatically lowered in CL-S- and PL-B-treated groups compared with PBS-treated group. CL-S- and PL-B-treated group were kept corneal translucency and little influx of polymorphonuclear neutrophils in histopathological examination. In addition, both CL-S- and PL-B-treated groups were not detected viable bacteria in infected cornea. Using our MDRP keratitis model, we showed that topical levofloxacin and CL-M are not adequately effective, while CL-S and PL-B are efficacious in controlling MDRP keratitis. Especially, PL-B, which is commercially available eye drop, might be most effective against MDRP. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. Liquid crystal droplet formation and anchoring dynamics in a microfluidic device

    NASA Astrophysics Data System (ADS)

    Steinhaus, Ben; Shen, Amy; Feng, James; Link, Darren

    2004-11-01

    Liquid crystal drops dispersed in a continuous phase of silicon oil are generated with a narrow distribution in droplet size in microfluidic devices both above and below the nematic to isotropic transition temperature. For these two cases, we observe not only the different LC droplet generation and coalescence dynamics, but also distinct droplet morphology. Our experiments show that the nematic liquid crystalline order is important for the LC droplet formation and anchoring dynamics.

  4. Addressing the efficiency roll-off in a fluorescent OLED by facile electron transport layer doping and carrier confinement

    NASA Astrophysics Data System (ADS)

    Soman, Anjaly; M, Manuraj; Unni, K. N. Narayanan

    2018-05-01

    Organic light emitting diodes (OLEDs) often face the issue of decreasing power efficiency with increasing brightness. Loss of charge carrier balance is one of the factors contributing to the efficiency roll-off. We demonstrate that by using a combination of doped electron transport layer (ETL) and a specially chosen electron blocking layer (EBL) having high hole mobility, this efficiency roll-off can be effectively suppressed. A tris-(8-hydroxyquinoline) aluminium (Alq3) based OLED has been fabricated with 2,3,6,7-Tetrahydro-1,1,7,7,-tetramethyl-1H, 5H,11H-10-(2-benzothiazolyl) quinolizino-[9,9a, 1n gh]coumarin (C545T) as the emissive dopant. Bulk doping of the ETL with lithium fluoride (LiF) was optimized to increase the luminous intensity as well as the current efficiency. An EBL with high hole mobility introduced between the EML and the hole transport layer (HTL) improved the performance drastically, and the device brightness at 9 V got improved by a factor of 2.5 compared to that of the control device. While increasing the brightness from 100 cd/m2 to 1000 cd/m2, the power efficiency drop was 47% for the control device whereas only a drop of 15% was observed for the modified device. The possible mechanisms for the enhanced performance are discussed.

  5. Radiofrequency-Based Identification Medical Device: An Evaluable Solution for Surgical Sponge Retrieval?

    PubMed

    Lazzaro, Alessandra; Corona, Arianna; Iezzi, Luca; Quaresima, Silvia; Armisi, Luca; Piccolo, Ilaria; Medaglia, Carlo Maria; Sbrenni, Sergio; Sileri, Pierpaolo; Rosato, Nicola; Gaspari, Achille Lucio; Di Lorenzo, Nicola

    2017-06-01

    A retained surgical item in patients (gossypiboma) is a persisting problem, despite consistent improvements and existing guidelines in counting instruments and sponges. Previous experiences with radiofrequency identification technology (RFID) tracking sponges show that it could represent an innovation, in order to reduce the criticism and increase the effectiveness during surgical procedures. We present an automated system that allows reduction of errors and improves safety in the operating room. The system consists of 3 antennas, surgical sponges containing RFID tags, and dedicated software applications, with Wi-Fi real-time communication between devices. The first antenna provides the initial count of gauzes; the second a real-time counting during surgery, including the sponges thrown into the kick-bucket; and the third can be used in the event of uneven sponge count. The software allows management at all stages of the process. In vitro and in vivo tests were performed: the system provided excellent results in detecting sponges in patients' body. Hundred percent retained sponges were detected correctly, even when they were overlapped. No false positive or false negative was recorded. The counting procedure turned out to be more streamlined and efficient and it could save time in a standard procedure. The RFID system for sponge tracking was shown to be experimentally a reliable and feasible method to track sponges with a full detection accuracy in the operating room. The results indicate the system to be safe and effective with acceptable cost-effective parameters.

  6. How valid are wearable physical activity trackers for measuring steps?

    PubMed

    An, Hyun-Sung; Jones, Gregory C; Kang, Seoung-Ki; Welk, Gregory J; Lee, Jung-Min

    2017-04-01

    Wearable activity trackers have become popular for tracking individual's daily physical activity, but little information is available to substantiate the validity of these devices in step counts. Thirty-five healthy individuals completed three conditions of activity tracker measurement: walking/jogging on a treadmill, walking over-ground on an indoor track, and a 24-hour free-living condition. Participants wore 10 activity trackers at the same time for both treadmill and over-ground protocol. Of these 10 activity trackers three were randomly given for 24-hour free-living condition. Correlations of steps measured to steps observed were r = 0.84 and r = 0.67 on a treadmill and over-ground protocol, respectively. The mean MAPE (mean absolute percentage error) score for all devices and speeds on a treadmill was 8.2% against manually counted steps. The MAPE value was higher for over-ground walking (9.9%) and even higher for the 24-hour free-living period (18.48%) on step counts. Equivalence testing for step count measurement resulted in a significant level within ±5% for the Fitbit Zip, Withings Pulse, and Jawbone UP24 and within ±10% for the Basis B1 band, Garmin VivoFit, and SenseWear Armband Mini. The results show that the Fitbit Zip and Withings Pulse provided the most accurate measures of step count under all three different conditions (i.e. treadmill, over-ground, and 24-hour condition), and considerable variability in accuracy across monitors and also by speeds and conditions.

  7. 75 FR 13172 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... internal distributors count and report each server and display device that processes TotalView-ITCH data as a professional TotalView and OpenView user. Some firms report upwards of 500 devices, while other.... Nasdaq has offered similar enterprise licenses for professional and non-professional usage of TotalView...

  8. Experimental flow studies in glaucoma drainage device development.

    PubMed

    2001-10-01

    (I) To examine whether small holes produced by 248 nm excimer laser ablation in a polymer substrate could consistently produce a pressure drop in the desired target range (5-15 mm Hg) at physiological aqueous flow rates for use as an internal flow restrictor in a glaucoma drainage device, and (ii) to investigate whether external leakage could be reduced in comparison with conventional tube and plate glaucoma drainage devices by redesigning the exterior cross sectional shape of the portion contained within the sclerocorneal tunnel. Single holes with target diameters of 10 microm, 15 microm, 20 microm, and 25 microm were drilled using a 248 nm excimer laser in sample discs (n=6 at each diameter) punched from a 75 microm thick polyimide sheet. Sample discs were tested in a flow rig designed to measure the pressure drop across the discs. Using filtered, degassed water at a flow rate of 1.4 microl/min repeated flow measurements were taken (n=6) for each disc. After flow testing, all discs were imaged using a scanning electron microscope and the dimensions of each hole were derived using image analysis software. In the external leakage study, corneoscleral buttons (n=13) were prepared from cadaver pig eyes and mounted on an artificial anterior chamber infused with Tyrode solution. After the pressure had stabilised, standard occluded silicone tube implants were inserted through 23 gauge needle stab incisions at the limbus. These were compared against prototype PMMA implants with a novel shape profile inserted through 1.15 mm width microvitreoretinal (MVR) stab incisions at the limbus. The infusion rate was maintained and a second pressure measurement was taken when the pressure had stabilised. The difference between the first and second pressure measurement was then compared, as an index of external leakage. Ablated tubes were found to have a near perfect circular outline on both the entry and exit side. The observed pressure drops across the ablated sample discs at each target diameter were as follows: 10 microm, mean 25.66 (SD 4.9) mm Hg; 15 microm, 6.7 (1.15); 20 microm, 1.66 (1.07); and 25 microm, <0.1 mm Hg. A strong correlation was observed between observed pressure drops and those predicted by Poiseuille's formula (R(2) =0.996). Target ablations of 15 microm diameter produced tubes that consistently achieved a pressure drop within the desired range (5-15 mm Hg). In the external leakage study, preinsertion pressures (mm Hg; mean (SD)) were 19.00 (4.3) (conventional method) and 20.00 (3.9) (new technique with PMMA prototypes). Post-insertion pressures were significantly reduced (10.40 (7.7); p<0.01) for the conventional technique and were essentially unchanged for the new technique (18.80 (4.9); p>0.1). It was shown that it is possible, in principle, to control the dimensions of a manufactured tubular lumen in a glaucoma drainage device accurately enough to provide consistent protection from hypotony in the early period after glaucoma filtration surgery. By redesigning the external profile of glaucoma drainage device and incision technique, it was also shown that it is possible to eliminate uncontrolled external leakage.

  9. Rapidly-Indexing Incremental-Angle Encoder

    NASA Technical Reports Server (NTRS)

    Christon, Philip R.; Meyer, Wallace W.

    1989-01-01

    Optoelectronic system measures relative angular position of shaft or other device to be turned, also measures absolute angular position after device turned through small angle. Relative angular position measured with fine resolution by optoelectronically counting finely- and uniformly-spaced light and dark areas on encoder disk as disk turns past position-sensing device. Also includes track containing coarsely- and nonuniformly-spaced light and dark areas, angular widths varying in proportion to absolute angular position. This second track provides gating and indexing signal.

  10. Microgravity

    NASA Image and Video Library

    2002-08-07

    Members from all four teams were mixed into pairs to work on a Lego (TM) Challenge device to operate in the portable drop tower demonstrator (background). These two team members are about to try out their LEGO (TM) creation. This was part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  11. Stable and metastable nanowires displaying locally controllable properties

    DOEpatents

    Sutter, Eli Anguelova; Sutter, Peter Werner

    2014-11-18

    Vapor-liquid-solid growth of nanowires is tailored to achieve complex one-dimensional material geometries using phase diagrams determined for nanoscale materials. Segmented one-dimensional nanowires having constant composition display locally variable electronic band structures that are determined by the diameter of the nanowires. The unique electrical and optical properties of the segmented nanowires are exploited to form electronic and optoelectronic devices. Using gold-germanium as a model system, in situ transmission electron microscopy establishes, for nanometer-sized Au--Ge alloy drops at the tips of Ge nanowires (NWs), the parts of the phase diagram that determine their temperature-dependent equilibrium composition. The nanoscale phase diagram is then used to determine the exchange of material between the NW and the drop. The phase diagram for the nanoscale drop deviates significantly from that of the bulk alloy.

  12. Establishing a gold standard for manual cough counting: video versus digital audio recordings

    PubMed Central

    Smith, Jaclyn A; Earis, John E; Woodcock, Ashley A

    2006-01-01

    Background Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. Methods We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. Results The median cough frequency was 17.8 (IQR 5.9–28.7) cough sounds per hour in the video recordings and 17.7 (6.0–29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD ± 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2–4 hours of analysis per recording. Conclusion Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment. PMID:16887019

  13. vitisFlower®: Development and Testing of a Novel Android-Smartphone Application for Assessing the Number of Grapevine Flowers per Inflorescence Using Artificial Vision Techniques

    PubMed Central

    Aquino, Arturo; Millan, Borja; Gaston, Daniel; Diago, María-Paz; Tardaguila, Javier

    2015-01-01

    Grapevine flowering and fruit set greatly determine crop yield. This paper presents a new smartphone application for automatically counting, non-invasively and directly in the vineyard, the flower number in grapevine inflorescence photos by implementing artificial vision techniques. The application, called vitisFlower®, firstly guides the user to appropriately take an inflorescence photo using the smartphone’s camera. Then, by means of image analysis, the flowers in the image are detected and counted. vitisFlower® has been developed for Android devices and uses the OpenCV libraries to maximize computational efficiency. The application was tested on 140 inflorescence images of 11 grapevine varieties taken with two different devices. On average, more than 84% of flowers in the captures were found, with a precision exceeding 94%. Additionally, the application’s efficiency on four different devices covering a wide range of the market’s spectrum was also studied. The results of this benchmarking study showed significant differences among devices, although indicating that the application is efficiently usable even with low-range devices. vitisFlower is one of the first applications for viticulture that is currently freely available on Google Play. PMID:26343664

  14. Characterization of spectrometric photon-counting X-ray detectors at different pitches

    NASA Astrophysics Data System (ADS)

    Jurdit, M.; Brambilla, A.; Moulin, V.; Ouvrier-Buffet, P.; Radisson, P.; Verger, L.

    2017-09-01

    There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm2. Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 106 incident photons.s-1.mm-2.

  15. Calorie counting and fitness tracking technology: Associations with eating disorder symptomatology.

    PubMed

    Simpson, Courtney C; Mazzeo, Suzanne E

    2017-08-01

    The use of online calorie tracking applications and activity monitors is increasing exponentially. Anecdotal reports document the potential for these trackers to trigger, maintain, or exacerbate eating disorder symptomatology. Yet, research has not examined the relation between use of these devices and eating disorder-related attitudes and behaviors. This study explored associations between the use of calorie counting and fitness tracking devices and eating disorder symptomatology. Participants (N=493) were college students who reported their use of tracking technology and completed measures of eating disorder symptomatology. Individuals who reported using calorie trackers manifested higher levels of eating concern and dietary restraint, controlling for BMI. Additionally, fitness tracking was uniquely associated with ED symptomatology after adjusting for gender and bingeing and purging behavior within the past month. Findings highlight associations between use of calorie and fitness trackers and eating disorder symptomatology. Although preliminary, overall results suggest that for some individuals, these devices might do more harm than good. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Design of a micromachined terahertz electromagnetic crystals (EMXT) channel-drop filter on silicon-substrate

    NASA Astrophysics Data System (ADS)

    Zhou, Kai; Liu, Yong; Si, Liming; Lv, Xin

    2013-08-01

    An integrated 0.5 THz electromagnetic crystals(EMXT) channel-drop filter based on PBG structure is presented in this paper. A channel-drop filter is a device in which a narrow bandwidth is redirected to another "drop" waveguide while other frequencies are unaffected. It's capable of extracting a certain frequency from a continuous spectrum in the bus channel and passing it to the test channel. It has potential applications in photonic integrated circuits, radio astronomy, THz spectroscopy, THz communication and remote sensing radar receiver. PBG structures(or photonic crystals) are periodic structures which possess band gaps, where the electromagnetic wave of certain ranges of frequencies cannot pass through and is reflected. The proposed channel-drop filter consists of input waveguide,output waveguide and PBG structure. The proposed filter is simulated using the finite element method and can be fabricated by micro-electromechanical systems (MEMS) technology,due to its low cost, high performance and high processing precision.The filter operation principle and fabrication process are discussed.The simulation results show its ability to filter the frequency of 496GHz with a linewidth of approximately 4GHz and transmission of 27.2 dB above background.The loss at resonant frequency is less than 1dB considering the thickness and roughness of gold layer required by the MEMS process.The channel drop efficiency is 84%.

  17. Microbial colonization in diverse surface soil types in Surtsey and diversity analysis of its subsurface microbiota

    NASA Astrophysics Data System (ADS)

    Marteinsson, V.; Klonowski, A.; Reynisson, E.; Vannier, P.; Sigurdsson, B. D.; Ólafsson, M.

    2015-02-01

    Colonization of life on Surtsey has been observed systematically since the formation of the island 50 years ago. Although the first colonisers were prokaryotes, such as bacteria and blue-green algae, most studies have been focused on the settlement of plants and animals but less on microbial succession. To explore microbial colonization in diverse soils and the influence of associated vegetation and birds on numbers of environmental bacteria, we collected 45 samples from different soil types on the surface of the island. Total viable bacterial counts were performed with the plate count method at 22, 30 and 37 °C for all soil samples, and the amount of organic matter and nitrogen (N) was measured. Selected samples were also tested for coliforms, faecal coliforms and aerobic and anaerobic bacteria. The subsurface biosphere was investigated by collecting liquid subsurface samples from a 181 m borehole with a special sampler. Diversity analysis of uncultivated biota in samples was performed by 16S rRNA gene sequences analysis and cultivation. Correlation was observed between nutrient deficits and the number of microorganisms in surface soil samples. The lowest number of bacteria (1 × 104-1 × 105 cells g-1) was detected in almost pure pumice but the count was significantly higher (1 × 106-1 × 109 cells g-1) in vegetated soil or pumice with bird droppings. The number of faecal bacteria correlated also to the total number of bacteria and type of soil. Bacteria belonging to Enterobacteriaceae were only detected in vegetated samples and samples containing bird droppings. The human pathogens Salmonella, Campylobacter and Listeria were not in any sample. Both thermophilic bacteria and archaea 16S rDNA sequences were found in the subsurface samples collected at 145 and 172 m depth at 80 and 54 °C, respectively, but no growth was observed in enrichments. The microbiota sequences generally showed low affiliation to any known 16S rRNA gene sequences.

  18. Microbial colonisation in diverse surface soil types in Surtsey and diversity analysis of its subsurface microbiota

    NASA Astrophysics Data System (ADS)

    Marteinsson, V.; Klonowski, A.; Reynisson, E.; Vannier, P.; Sigurdsson, B. D.; Ólafsson, M.

    2014-09-01

    Colonisation of life on Surtsey has been observed systematically since the formation of the island 50 years ago. Although the first colonisers were prokaryotes, such as bacteria and blue-green algae, most studies have been focusing on settlement of plants and animals but less on microbial succession. To explore microbial colonization in diverse soils and the influence of associate vegetation and birds on numbers of environmental bacteria, we collected 45 samples from different soils types on the surface of the island. Total viable bacterial counts were performed with plate count at 22, 30 and 37 °C for all soils samples and the amount of organic matter and nitrogen (N) was measured. Selected samples were also tested for coliforms, faecal coliforms aerobic and anaerobic bacteria. The deep subsurface biosphere was investigated by collecting liquid subsurface samples from a 182 m borehole with a special sampler. Diversity analysis of uncultivated biota in samples was performed by 16S rRNA gene sequences analysis and cultivation. Correlation was observed between N deficits and the number of microorganisms in surface soils samples. The lowest number of bacteria (1 × 104-1 × 105 g-1) was detected in almost pure pumice but the count was significant higher (1 × 106-1 × 109 g-1) in vegetated soil or pumice with bird droppings. The number of faecal bacteria correlated also to the total number of bacteria and type of soil. Bacteria belonging to Enterobacteriaceae were only detected in vegetated and samples containing bird droppings. The human pathogens Salmonella, Campylobacter and Listeria were not in any sample. Both thermophilic bacteria and archaea 16S rDNA sequences were found in the subsurface samples collected at 145 m and 172 m depth at 80 °C and 54 °C, respectively, but no growth was observed in enrichments. The microbiota sequences generally showed low affiliation to any known 16S rRNA gene sequences.

  19. Particle count and black carbon measurements at schools in Las Vegas, NV and in the greater Salt Lake City, UT area.

    PubMed

    Brown, Steven G; Vaughn, David L; Roberts, Paul T

    2017-11-01

    As part of two separate studies aimed to characterize ambient pollutant concentrations at schools in urban areas, we compare black carbon and particle count measurements at Adcock Elementary in Las Vegas, NV (April-June 2013), and Hunter High School in the West Valley City area of greater Salt Lake City, UT (February 2012). Both schools are in urban environments, but Adcock Elementary is next to the U.S. 95 freeway. Black carbon (BC) concentrations were 13% higher at Adcock compared to Hunter, while particle count concentrations were 60% higher. When wind speeds were low-less than 2 m/sec-both BC and particle count concentrations were significantly higher at Adcock, while concentrations at Hunter did not have as strong a variation with wind speed. When wind speeds were less than 2 m/sec, emissions from the adjacent freeway greatly affected concentrations at Adcock, regardless of wind direction. At both sites, BC and particle count concentrations peaked in the morning during commute hours. At Adcock, particle count also peaked during midday or early afternoon, when BC was low and conditions were conducive to new particle formation. While this midday peak occurred at Adcock on roughly 45% of the measured days, it occurred on only about 25% of the days at Hunter, since conditions for particle formation (higher solar radiation, lower wind speeds, lower relative humidity) were more conducive at Adcock. Thus, children attending these schools are likely to be exposed to pollution peaks during school drop-off in the morning, when BC and particle count concentrations peak, and often again during lunchtime recess when particle count peaks again. Particle count concentrations at two schools were shown to typically be independent of BC or other pollutants. At a school in close proximity to a major freeway, particle count concentrations were high during the midday and when wind speeds were low, regardless of wind direction, showing a large area of effect from roadway emissions even when the school was not downwind of the roadway. At the second school, which sits in an urban neighborhood away from freeways, high particle counts occurred even though solar radiation was low during wintertime conditions, meaning that exposure to high particle counts can occur throughout the year.

  20. Comparison of biological H2S removal characteristics between a composite packing material with and without functional microorganisms

    NASA Astrophysics Data System (ADS)

    Zhu, Rencheng; Li, Shunyi; Bao, Xiaofeng; Dumont, Éric

    2017-02-01

    The performances of two identical biofilters, filled with a new composite packing material (named CM-5) embedded with functional microorganisms or sterilized CM-5 without microorganisms, were investigated for H2S treatment. Running parameters in terms of microbial counts, pressure drops, and inlet and outlet H2S concentrations were measured. The results show that the microbial count of the CM-5 was approximately ×105 CFU/g before being filled into the biofilter, while that of the sterilized CM-5 was negligible. The functional microorganisms embedded in CM-5 adapted to the environment containing H2S quickly. In most cases, pressure drops of the CM-5 biofilter were slightly higher than those of the sterilized CM-5 biofilter when the gas flow rate was 0.6-2.5 m3/h. The maximum elimination capacity (EC) of the CM-5 biofilter in treating H2S could reach up to 65 g/(m3·h) when the loading rate (LR) was approximately 80 g/(m3·h). If the LR was much higher, the measured EC showed a slight downward trend. The experimental ECs of biofilters were fitted by two typical dynamic models: the Michaelis-Menten model and the Haldane model. Compared with the Michaelis-Menten model, the Haldane model fit the experimental ECs better for the two biofilters because of the presence of the substrate inhibition behaviour.

  1. Comparison of biological H2S removal characteristics between a composite packing material with and without functional microorganisms

    PubMed Central

    Zhu, Rencheng; Li, Shunyi; Bao, Xiaofeng; Dumont, Éric

    2017-01-01

    The performances of two identical biofilters, filled with a new composite packing material (named CM-5) embedded with functional microorganisms or sterilized CM-5 without microorganisms, were investigated for H2S treatment. Running parameters in terms of microbial counts, pressure drops, and inlet and outlet H2S concentrations were measured. The results show that the microbial count of the CM-5 was approximately ×105 CFU/g before being filled into the biofilter, while that of the sterilized CM-5 was negligible. The functional microorganisms embedded in CM-5 adapted to the environment containing H2S quickly. In most cases, pressure drops of the CM-5 biofilter were slightly higher than those of the sterilized CM-5 biofilter when the gas flow rate was 0.6–2.5 m3/h. The maximum elimination capacity (EC) of the CM-5 biofilter in treating H2S could reach up to 65 g/(m3·h) when the loading rate (LR) was approximately 80 g/(m3·h). If the LR was much higher, the measured EC showed a slight downward trend. The experimental ECs of biofilters were fitted by two typical dynamic models: the Michaelis-Menten model and the Haldane model. Compared with the Michaelis-Menten model, the Haldane model fit the experimental ECs better for the two biofilters because of the presence of the substrate inhibition behaviour. PMID:28198800

  2. Comparative evaluation of yogurt and low-fat cheddar cheese as delivery media for probiotic Lactobacillus casei.

    PubMed

    Sharp, M D; McMahon, D J; Broadbent, J R

    2008-09-01

    This study used Lactobacillus casei 334e, an erythromycin-resistant derivative of ATCC 334, as a model to evaluate viability and acid resistance of probiotic L. casei in low-fat Cheddar cheese and yogurt. Cheese and yogurt were made by standard methods and the probiotic L. casei adjunct was added at approximately 10(7) CFU/g with the starter cultures. Low-fat cheese and yogurt samples were stored at 8 and 2 degrees C, respectively, and numbers of the L. casei adjunct were periodically determined by plating on MRS agar that contained 5 microg/mL of erythromycin. L. casei 334e counts in cheese and yogurt remained at 10(7) CFU/g over 3 mo and 3 wk, respectively, indicating good survival in both products. Acid challenge studies in 8.7 mM phosphoric acid (pH 2) at 37 degrees C showed numbers of L. casei 334e in yogurt dropped from 10(7) CFU/g to less than 10(1) CFU/g after 30 min, while counts in cheese samples dropped from 10(7) CFU/g to about 10(5) after 30 min, and remained near 10(4) CFU/g after 120 min. As a whole, these data showed that low-fat Cheddar cheese is a viable delivery food for probiotic L. casei because it allowed for good survival during storage and helped protect cells against the very low pH that will be encountered during stomach transit.

  3. A TiAlCu Metallization for ` n' Type CoSb_x Skutterudites with Improved Performance for High-Temperature Energy Harvesting Applications

    NASA Astrophysics Data System (ADS)

    Rao, Ashwin; Bosak, Gregg; Joshi, Binay; Keane, Jennifer; Nally, Luke; Peng, Adam; Perera, Susanthri; Waring, Alfred; Poudel, Bed

    2017-04-01

    The choice of the appropriate metallizing layer for high-temperature thermoelectric (TE) materials is a tricky task and poses varied challenges to researchers. In this work, a n type TiAl metallizing layer (90% Ti with 10% Al by weight with a copper foil) is proposed for a Yb_{0.2}Co4Sb_{12} skutterudite (SK) TE material coupled with a standard ` p type' SK base of Nd_{0.45}Ce_{0.45}Fe_{3.5}Co_{0.5}Sb_{12} with a 60:12:28% Fe:Ni:Cr metallizing layer. The n type and p type nanostructured SK powders are sintered at high temperatures and pressures in a DC hot press from which a TE device is assembled using diced, polished and property characterized TE legs (high figure of merit zT of 1.4 for n type and 1.2 for p type, respectively). The device is evaluated for functional degradation with repeated cycling to 500°C hot side (HS) and 50°C cold side (CS) temperatures in a specially designed high-vacuum test rig with key TE properties like peak power, open circuit voltage, and material internal resistance continuously recorded over each cycle. The device shows stable performance with <7% drop in TE harvested power over 2500 thermal cycles. With the industry benchmark for evaluating TE device performance being around 1000 thermal cycles (<10% drop in TE power over time), the study indicates stable performance of the n type TiAl metallizing layer over the device lifetime.

  4. A Reliable Data Transmission Model for IEEE 802.15.4e Enabled Wireless Sensor Network under WiFi Interference.

    PubMed

    Sahoo, Prasan Kumar; Pattanaik, Sudhir Ranjan; Wu, Shih-Lin

    2017-06-07

    The IEEE 802.15.4e standard proposes Medium Access Control (MAC) to support collision-free wireless channel access mechanisms for industrial, commercial and healthcare applications. However, unnecessary wastage of energy and bandwidth consumption occur due to inefficient backoff management and collisions. In this paper, a new channel access mechanism is designed for the buffer constraint sensor devices to reduce the packet drop rate, energy consumption and collisions. In order to avoid collision due to the hidden terminal problem, a new frame structure is designed for the data transmission. A new superframe structure is proposed to mitigate the problems due to WiFi and ZigBee interference. A modified superframe structure with a new retransmission opportunity for failure devices is proposed to reduce the collisions and retransmission delay with high reliability. Performance evaluation and validation of our scheme indicate that the packet drop rate, throughput, reliability, energy consumption and average delay of the nodes can be improved significantly.

  5. 5.0 kV breakdown-voltage vertical GaN p-n junction diodes

    NASA Astrophysics Data System (ADS)

    Ohta, Hiroshi; Hayashi, Kentaro; Horikiri, Fumimasa; Yoshino, Michitaka; Nakamura, Tohru; Mishima, Tomoyoshi

    2018-04-01

    A high breakdown voltage of 5.0 kV has been achieved for the first time in vertical GaN p-n junction diodes by using our newly developed guard-ring structures. A resistance device was inserted between the main diode portion and the guard-ring portion in a ring-shaped p-n diode to generate a voltage drop over the resistance device by leakage current flowing through the guard-ring portion under negatively biased conditions before breakdown. The voltage at the outer mesa edge of the guard-ring portion, where the electric field intensity is highest and the destructive breakdown usually occurs, is decreased by the voltage drop, so the electric field concentration in the portion is reduced. By adopting this structure, the breakdown voltage (V B) is raised by about 200 V. Combined with a low measured on-resistance (R on) of 1.25 mΩ cm2, Baliga’s figure of merit (V\\text{B}2/R\\text{on}) was as high as 20 GW/cm2.

  6. A clinical trial of WRL 105 strain live attenuated influenza vaccine comparing four methods of intranasal vaccination.

    PubMed Central

    Freestone, D. S.; Bowker, C. H.; Letley, E.; Ferris, R. D.; White, W. G.; Barnes, G. M.

    1976-01-01

    A single intranasal dose of 10(7-0) EID50 recombinant WRL 105 strain live attenuated influenza vaccine was administered intranasally to 193 volunteers either as nose drops or by one of three spray devices which produced sprays of differing physical characteristics. In volunteers with homologous haemagglutinating inhibiting antibody titres of less than or equal to 20 before vaccination, seroconversion rates varied widely from 80% following the administration of drops to 71%, 57% and 28% with the three spray devices. In the week following vaccination 16 (22%) of 74 volunteers who were found to show a fourfold or greater antibody response to took analgesics to control symptoms in comparison with 4 (7%) of 58 volunteers who exhibited no serological response to vaccination (P less than 0-05). However, neither the occurrence of upper respiratory nor systemic symptoms were significantly different in these two groups and the degree of attenuation of the recombinant WRL 105 strain appears to be acceptable for future use. PMID:1064672

  7. Modeling of Yb3+/Er3+-codoped microring resonators

    NASA Astrophysics Data System (ADS)

    Vallés, Juan A.; Gălătuş, Ramona

    2015-03-01

    The performance of a highly Yb3+/Er3+-codoped phosphate glass add-drop microring resonator is numerically analyzed. The model assumes resonant behaviour of both pump and signal powers and the dependences of pump intensity build-up inside the microring resonator and of the signal transfer functions to the device through and drop ports are evaluated. Detailed equations for the evolution of the rare-earth ions levels population densities and the propagation of the optical powers inside the microring resonator are included in the model. Moreover, due to the high dopant concentrations considered, the microscopic statistical formalism based on the statistical average of the excitation probability of the Er3+ ion in a microscopic level has been used to describe energy-transfer inter-atomic mechanisms. Realistic parameters and working conditions are used for the calculations. Requirements to achieve amplification and laser oscillation within these devices are obtainable as a function of rare earth ions concentration and coupling losses.

  8. A Reliable Data Transmission Model for IEEE 802.15.4e Enabled Wireless Sensor Network under WiFi Interference

    PubMed Central

    Sahoo, Prasan Kumar; Pattanaik, Sudhir Ranjan; Wu, Shih-Lin

    2017-01-01

    The IEEE 802.15.4e standard proposes Medium Access Control (MAC) to support collision-free wireless channel access mechanisms for industrial, commercial and healthcare applications. However, unnecessary wastage of energy and bandwidth consumption occur due to inefficient backoff management and collisions. In this paper, a new channel access mechanism is designed for the buffer constraint sensor devices to reduce the packet drop rate, energy consumption and collisions. In order to avoid collision due to the hidden terminal problem, a new frame structure is designed for the data transmission. A new superframe structure is proposed to mitigate the problems due to WiFi and ZigBee interference. A modified superframe structure with a new retransmission opportunity for failure devices is proposed to reduce the collisions and retransmission delay with high reliability. Performance evaluation and validation of our scheme indicate that the packet drop rate, throughput, reliability, energy consumption and average delay of the nodes can be improved significantly. PMID:28590434

  9. Comparability of children's sedentary time estimates derived from wrist worn GENEActiv and hip worn ActiGraph accelerometer thresholds.

    PubMed

    Boddy, Lynne M; Noonan, Robert J; Kim, Youngwon; Rowlands, Alex V; Welk, Greg J; Knowles, Zoe R; Fairclough, Stuart J

    2018-03-28

    To examine the comparability of children's free-living sedentary time (ST) derived from raw acceleration thresholds for wrist mounted GENEActiv accelerometer data, with ST estimated using the waist mounted ActiGraph 100count·min -1 threshold. Secondary data analysis. 108 10-11-year-old children (n=43 boys) from Liverpool, UK wore one ActiGraph GT3X+ and one GENEActiv accelerometer on their right hip and left wrist, respectively for seven days. Signal vector magnitude (SVM; mg) was calculated using the ENMO approach for GENEActiv data. ST was estimated from hip-worn ActiGraph data, applying the widely used 100count·min -1 threshold. ROC analysis using 10-fold hold-out cross-validation was conducted to establish a wrist-worn GENEActiv threshold comparable to the hip ActiGraph 100count·min -1 threshold. GENEActiv data were also classified using three empirical wrist thresholds and equivalence testing was completed. Analysis indicated that a GENEActiv SVM value of 51mg demonstrated fair to moderate agreement (Kappa: 0.32-0.41) with the 100count·min -1 threshold. However, the generated and empirical thresholds for GENEActiv devices were not significantly equivalent to ActiGraph 100count·min -1 . GENEActiv data classified using the 35.6mg threshold intended for ActiGraph devices generated significantly equivalent ST estimates as the ActiGraph 100count·min -1 . The newly generated and empirical GENEActiv wrist thresholds do not provide equivalent estimates of ST to the ActiGraph 100count·min -1 approach. More investigation is required to assess the validity of applying ActiGraph cutpoints to GENEActiv data. Future studies are needed to examine the backward compatibility of ST data and to produce a robust method of classifying SVM-derived ST. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. DISCHARGE DEVICE FOR RADIOACTIVE MATERIAL

    DOEpatents

    Ohlinger, L.A.

    1958-09-23

    A device is described fur unloading bodies of fissionable material from a neutronic reactor. It is comprised essentially of a wheeled flat car having a receptacle therein containing a liquid coolant fur receiving and cooling the fuel elements as they are discharged from the reactor, and a reciprocating plunger fur supporting the fuel element during discharge thereof prior to its being dropped into the coolant. The flat car is adapted to travel along the face of the reactor adjacent the discharge ends of the coolant tubes.

  11. Human Electro-Muscular Incapacitation (HEMI) Devices Characterization: A Comparative Study on Stress and the Physiological Effects on Swine

    DTIC Science & Technology

    2011-07-07

    depending upon the device. As noted earlier, while the Stinger™S-200 and TASER ® X26 both resulted in tetany (sustained muscle contraction ), the cyclic...artificially maintained by the muscle contraction of the HEMI application. The stoppage of the HEMI “unmasked” the hypovolemia and the blood pressure...dropped. (2) The animals had normal blood volume with peripheral vascular resistance maintained by the HEMI ( muscle contraction ). When the HEMI

  12. Small conductive particle sensor. [microfiber size determination

    NASA Technical Reports Server (NTRS)

    Taback, I. (Inventor)

    1981-01-01

    An electrostatic conductive fiber detector is disclosed for use in detecting, counting and measuring the length of fibers down to 0.1 mm and below with increased accuracy and reliability over prior art devices. It can be used for detection of fibers suspending in a flowing gas, in a nonflowing gas, or in a vacuum and its accumulated counts over a period of time is essentially unaffected by velocity of the fibers being detected.

  13. Tracking Steps on Apple Watch at Different Walking Speeds.

    PubMed

    Veerabhadrappa, Praveen; Moran, Matthew Duffy; Renninger, Mitchell D; Rhudy, Matthew B; Dreisbach, Scott B; Gift, Kristin M

    2018-04-09

    QUESTION: How accurate are the step counts obtained from Apple Watch? In this validation study, video steps vs. Apple Watch steps (mean ± SD) were 2965 ± 144 vs. 2964 ± 145 steps; P < 0.001. Lin's concordance correlation coefficient showed a strong correlation (r = 0.96; P < 0.001) between the two measurements. There was a total error of 0.034% (1.07 steps) for the Apple Watch steps when compared with the manual counts obtained from video recordings. Our study is one of the initial studies to objectively validate the accuracy of the step counts obtained from Apple watch at different walking speeds. Apple Watch tested to be an extremely accurate device for measuring daily step counts for adults.

  14. Safety of a progesterone-releasing intravaginal device as assessed from vaginal mucosal integrity and indicators of systemic inflammation in postpartum dairy cows

    PubMed Central

    Walsh, Robert B.; LeBlanc, Stephen J.; Vernooy, Erin; Leslie, Kenneth E.

    2008-01-01

    A clinical trial was conducted to investigate the animal safety of a progesterone-releasing intravaginal device (PRID). Anestrus cows at a mean of 63 ± 3.5 d in milk were randomly assigned to an ovulation-synchronization protocol that included placement of either a PRID or a placebo intravaginal device (PID) or no such treatment. At enrolment and at device removal 7 d later, blood samples were collected. The outcomes of interest included the vaginal reaction to the device, the vaginal mucosal integrity, and the results of bacterial culture of swabs of the vaginal mucosa. In addition, the leukocyte and haptoglobin responses were measured. Although only 5% of the PRID-treated animals compared with 19% of the PID-treated animals had a copious purulent vaginal discharge at the time of device removal, there was no significant difference in the proportions; furthermore, there was no evidence of vaginal mucosal damage associated with either device. The total blood leukocyte count was significantly lower in both the PRID-treated cows and the PID-treated cows after device removal compared with the start of treatment (P < 0.05) and compared with no treatment (P < 0.001); there was no difference in leukocyte response between the 2 device-treated groups. The decrease in leukocyte count was attributed to a significant reduction in the numbers of circulating neutrophils and lymphocytes, a pattern consistent with the luteal phase of the bovine estrus cycle. There was no significant difference in the circulating haptoglobin concentration between the 3 groups of cows. Culture revealed commensal bacterial growth in the vagina of all the cows. PMID:18214161

  15. LIBS and LIFS for rapid detection of Rb traces in blood

    NASA Astrophysics Data System (ADS)

    Al-Jeffery, Mohammad O.; Telle, Helmut H.

    2002-05-01

    Tests that can quickly and efficiently detect traces of illegal performance enhancing drugs are becoming essential. Certain performance enhancing drugs lead to an increase in the count of red blood cells. The proportion of blood made up of red cells is normally around 42 percent. At least 90 percent of Rubidium measured in whole blood is located in the red blood cells. If Rubidium Chloride (RbCl) is given to an athlete around 30 minutes before competing and a sample of their blood (a drop on a filter) was subsequently tested for Rubidium content, the test will give a direct indication of the red blood cell count. In this contribution, we describe an efficient and fast test based on spectroscopic techniques that can be used to detect trace levels of Rubidium. Our experiments employed Rubidium nitride (RbNO3) and trace levels down to 0.3 percent were successfully detected.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, R.J.; Qian, J.K.; Yang, G.H.

    Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (pmore » less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.« less

  17. Granulocyte colony stimulating factor (G-CSF) can allow treatment with clozapine in a patient with severe benign ethnic neutropaenia (BEN): a case report.

    PubMed

    Spencer, Benjamin W J; Williams, Hugh R J; Gee, Siobhan H; Whiskey, Eromona; Rodrigues, Joseph P; Mijovic, Aleksandar; MacCabe, James H

    2012-09-01

    Clozapine is the treatment of choice for treatment-resistant schizophrenia, but it is associated with a risk of neutropaenia and agranulocytosis. Clozapine use is regulated by mandatory blood monitoring in the UK, requiring cessation of treatment should the absolute neutrophil count (ANC) drop below specified values. Benign reductions in the ANC in non-white populations are common, and this can preclude a patient from receiving treatment with clozapine. A diagnosis of benign ethnic neutropaenia can reduce these treatment restrictions (UK specific), but the degree of neutropaenia can be significant enough to still prevent treatment. In this report, we show that response to granulocyte colony stimulating factor (G-CSF) may be quite variable and difficult to predict, but with careful monitoring it can be used to increase the ANC count and allow continued treatment with clozapine.

  18. Electrostatically defined silicon quantum dots with counted antimony donor implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, M., E-mail: msingh@sandia.gov; Luhman, D. R.; Lilly, M. P.

    2016-02-08

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. In this work, a focused ion beam is used to implant antimony donors in 100 nm × 150 nm windows straddling quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of donors implanted can be counted to a precision of a single ion. In low-temperature transport measurements, regular Coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization are also observed in devices with counted donor implants.

  19. Electrostatically defined silicon quantum dots with counted antimony donor implants

    NASA Astrophysics Data System (ADS)

    Singh, M.; Pacheco, J. L.; Perry, D.; Garratt, E.; Ten Eyck, G.; Bishop, N. C.; Wendt, J. R.; Manginell, R. P.; Dominguez, J.; Pluym, T.; Luhman, D. R.; Bielejec, E.; Lilly, M. P.; Carroll, M. S.

    2016-02-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. In this work, a focused ion beam is used to implant antimony donors in 100 nm × 150 nm windows straddling quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of donors implanted can be counted to a precision of a single ion. In low-temperature transport measurements, regular Coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization are also observed in devices with counted donor implants.

  20. Development of a constant surface pressure penetration langmuir balance based on axisymmetric drop shape analysis.

    PubMed

    Wege, H A; Holgado-Terriza, J A; Cabrerizo-Vílchez, M A

    2002-05-15

    A new constant pressure pendant-drop penetration surface balance has been developed combining a pendant-drop surface balance, a rapid-subphase-exchange technique, and a fuzzy logic control algorithm. Beside the determination of insoluble monolayer compression-expansion isotherms, it allows performance of noninvasive kinetic studies of the adsorption of surfactants added to the new subphase onto the free surface and of the adsorption/penetration/reaction of the former onto/into/with surface layers, respectively. The interfacial pressure pi is a fundamental parameter in these studies: by working at constant pi one controls the height of the energy barrier to adsorption/penetration and can select different regimes and steps of the adsorption/penetration process. In our device a solution drop is formed at the tip of a coaxial double capillary, connected to a double microinjector. Drop profiles are extracted from digital drop micrographs and fitted to the equation of capillarity, yielding pi, the drop volume V, and the interfacial area A. pi is varied changing V (and hence A) with the microinjector. Control is based on a case-adaptable modulated fuzzy-logic PID algorithm able to maintain constant pi (or A) under a wide range of experimental conditions. The drop subphase liquid can be exchanged quantitatively by the coaxial capillaries. The adsorption/penetration/reaction kinetics at constant pi are then studied monitoring A(t), i.e., determining the relative area change necessary at each instant to compensate the pressure variation due to the interaction of the surfactant in the subsurface with the surface layer. A fully Windows-integrated program manages the whole setup. Examples of experimental protein adsorption and monolayer penetration kinetics are presented.

Top