Sample records for drop test 53-3

  1. Moment rate scaling for earthquakes 3.3 ≤ M ≤ 5.3 with implications for stress drop

    NASA Astrophysics Data System (ADS)

    Archuleta, Ralph J.; Ji, Chen

    2016-12-01

    We have determined a scalable apparent moment rate function (aMRF) that correctly predicts the peak ground acceleration (PGA), peak ground velocity (PGV), local magnitude, and the ratio of PGA/PGV for earthquakes 3.3 ≤ M ≤ 5.3. Using the NGA-West2 database for 3.0 ≤ M ≤ 7.7, we find a break in scaling of LogPGA and LogPGV versus M around M 5.3 with nearly linear scaling for LogPGA and LogPGV for 3.3 ≤ M ≤ 5.3. Temporal parameters tp and td—related to rise time and total duration—control the aMRF. Both scale with seismic moment. The Fourier amplitude spectrum of the aMRF has two corners between which the spectrum decays f- 1. Significant attenuation along the raypath results in a Brune-like spectrum with one corner fC. Assuming that fC ≅ 1/td, the aMRF predicts non-self-similar scaling M0∝fC3.3 and weak stress drop scaling Δσ∝M00.091. This aMRF can explain why stress drop is different from the stress parameter used to predict high-frequency ground motion.

  2. Predictors of Weapon Carrying in Youth Attending Drop-in Centers

    ERIC Educational Resources Information Center

    Blumberg, Elaine J.; Liles, Sandy; Kelley, Norma J.; Hovell, Melbourne F.; Bousman, Chad A.; Shillington, Audrey M.; Ji, Ming; Clapp, John

    2009-01-01

    Objective: To test and compare 2 predictive models of weapon carrying in youth (n=308) recruited from 4 drop-in centers in San Diego and Imperial counties. Methods: Both models were based on the Behavioral Ecological Model (BEM). Results: The first and second models significantly explained 39% and 53% of the variance in weapon carrying,…

  3. Evaluation on Dorsey Method in Surface Tension Measurement of Solder Liquids Containing Surfactants

    NASA Astrophysics Data System (ADS)

    Zhao, Xingke; Xie, Feiming; Fan, Jinsheng; Liu, Dayong; Huang, Jihua; Chen, Shuhai

    2018-06-01

    With the purpose of developing a feasible approach for measuring the surface tension of solders containing surfactants, the surface tension of Sn-3Ag-0.5Cu-xP solder alloys, with various drop sizes as well as different phosphorus (P) content, was evaluated using the Dorsey method based on the sessile drop test. The results show that the accuracy of the surface tension calculations depends on both of sessile drop size and the liquid metal composition. With a proper drop size, in the range of 4.5 mm to 5.3 mm in equivalent spherical diameters, the deviation of the surface tension calculation can be limited to 1.43 mN·m-1 and 6.30 mN·m-1 for SnAgCu and SnAgCu-P, respectively. The surface tension of SnAgCu-xP solder alloys decreases quickly to a minimum value when the P content reaches 0.5 wt% and subsequently increases slowly with the P content further increasing. The formation of a P-enriched surface layer and Sn4P3 intermetallic phases is regarded to be responsible for the decreasing and subsequent increasing of surface tension, respectively.

  4. Effect of airstream velocity on mean drop diameters of water sprays produced by pressure and air atomizing nozzles. [for combustion studies

    NASA Technical Reports Server (NTRS)

    Ingebo, R. D.

    1977-01-01

    A scanning radiometer was used to determine the effect of airstream velocity on the mean drop diameter of water sprays produced by pressure atomizing and air atomizing fuel nozzles used in previous combustion studies. Increasing airstream velocity from 23 to 53.4 meters per second reduced the Sauter mean diameter by approximately 50 percent with both types of fuel nozzles. The use of a sonic cup attached to the tip of an air assist nozzle reduced the Sauter mean diameter by approximately 40 percent. Test conditions included airstream velocities of 23 to 53.4 meters per second at 293 K and atmospheric pressure.

  5. Effect of airstream velocity on mean drop diameters of water sprays produced by pressure and air atomizing nozzles

    NASA Technical Reports Server (NTRS)

    Ingebo, R. D.

    1977-01-01

    A scanning radiometer was used to determine the effect of airstream velocity on the mean drop diameter of water sprays produced by pressure atomizing and air atomizing fuel nozzles used in previous combustion studies. Increasing airstream velocity from 23 to 53.4 meters per second reduced the Sauter mean diameter by approximately 50 percent with both types of fuel nozzles. The use of a sonic cup attached to the tip of an air assist nozzle reduced the Sauter mean diameter by approximately 40 percent. Test conditions included airstream velocities of 23 to 53.4 meters per second at 293 K and atmospheric pressure.

  6. Estimation of dynamic stability parameters from drop model flight tests

    NASA Technical Reports Server (NTRS)

    Chambers, J. R.; Iliff, K. W.

    1981-01-01

    The overall remotely piloted drop model operation, descriptions, instrumentation, launch and recovery operations, piloting concept, and parameter identification methods are discussed. Static and dynamic stability derivatives were obtained for an angle attack range from -20 deg to 53 deg. It is indicated that the variations of the estimates with angle of attack are consistent for most of the static derivatives, and the effects of configuration modifications to the model were apparent in the static derivative estimates.

  7. Dosage variability of topical ocular hypotensive products: a densitometric assessment.

    PubMed

    Gaynes, Bruce I; Singa, Ramesh M; Cao, Ying

    2009-02-01

    To ascertain consequence of variability in drop volume obtained from multiuse topical ocular hypotensive products in terms of uniformity of product dosage. Densitometric assessment of drop volume dispensed from 2 alternative bottle positions. All except one product demonstrated a statistically significant difference in drop volume when administered at either a 45-degree or 90-degree bottle angle (Student t test, P<0.001). Product-specific drop volume ranged from a nadir of 22.36 microL to a high of 53.54 microL depending on bottle angle of administration. Deviation in drop dose was directly proportional to variability in drop volume. Variability in per drop dosage was conspicuous among products with a coefficient of variation from 1.49% to 15.91%. In accordance with drop volume, all products demonstrated a statistically significant difference in drop dose at 45-degree versus 90-degree administration angles. Drop volume was found unrelated to drop uniformity (Spearman r=0.01987 and P=0.9463). Variability and lack of uniformity in drop dosage is clearly evident among select ocular hypotensive products and is related to angle of drop administration. Erratic dosage of topical ocular hypotensive therapy may contribute in part to therapeutic failure and/or toxicity.

  8. 49 CFR 178.810 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drop test. 178.810 Section 178.810 Transportation... Drop test. (a) General. The drop test must be conducted for the qualification of all IBC design types... the drop test. (1) Metal, rigid plastic, and composite IBCs intended to contain solids must be filled...

  9. 49 CFR 178.1045 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drop test. 178.1045 Section 178.1045... Containers § 178.1045 Drop test. (a) General. The drop test must be conducted for the qualification of all... subpart. (b) Special preparation for the drop test. Flexible Bulk Containers must be filled to their...

  10. 53. Same view. A slight raise and a quick drop ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    53. Same view. A slight raise and a quick drop was employed to remove the jammed mortised member. - Wabash & Erie Canal, Lock No. 2, 8 miles east of Fort Wayne, adjacent to U.S. Route 24, New Haven, Allen County, IN

  11. 49 CFR 178.965 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drop test. 178.965 Section 178.965 Transportation... Packagings § 178.965 Drop test. (a) General. The drop test must be conducted for the qualification of all...) Special preparation for the drop test. Large Packagings must be filled in accordance with § 178.960. (c...

  12. 49 CFR 178.603 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Drop test. 178.603 Section 178.603 Transportation... Packagings and Packages § 178.603 Drop test. (a) General. The drop test must be conducted for the... than flat drops, the center of gravity of the test packaging must be vertically over the point of...

  13. Additive Effect of preservative-free sodium hyaluronate 0.1% in treatment of dry eye syndrome with diquafosol 3% eye drops.

    PubMed

    Hwang, Ho Sik; Sung, Yoon-Mi; Lee, Weon Sun; Kim, Eun Chul

    2014-09-01

    The aim of this study was to evaluate the treatment effect of diquafosol 3% with preservative-free sodium hyaluronate 0.1% eye drops in dry eye syndrome. In total, 150 patients with dry eye syndrome were divided randomly into 3 groups. Group 1 (50 patients) was treated 4 times daily with preserved sodium hyaluronate 0.1%, group 2 (50 patients) was treated 4 times daily with diquafosol 3%, and group 3 (50 patients) was treated 4 times daily with diquafosol 3% and preservative-free sodium hyaluronate 0.1% eye drops for 3 months. Ocular surface disease index (OSDI) score, tear film break-up time, Schirmer I test, corneal fluorescein staining, and impression cytology were evaluated. There were significant improvements in the OSDI score, tear film break-up time, Schirmer I score, fluorescein and Rose Bengal staining, goblet cell density, and impression cytological findings in groups 2 and 3 compared with those for group 1 in patients with dry eye syndrome at 1, 2, and 3 months (P < 0.05). There were statistically significant improvements in the OSDI score (-8.48 ± 0.97, -5.69 ± 0.78; P = 0.02), fluorescein (-1.43 ± 0.21, -1.02 ± 0.18; P = 0.03), and Rose Bengal staining (-1.12 ± 0.26, -0.75 ± 0.12; P = 0.03), goblet cell density (89.65 ± 14.39, 70.36 ± 16.75; P = 0.03), and impression cytological findings (-0.53 ± 0.12, -0.34 ± 0.90; P = 0.01) in group 3 compared with those in group 2 at 3 months. Treatment with diquafosol 3% with preservative-free sodium hyaluronate 0.1% was more effective than diquafosol 3% monotherapy or treatment with preserved sodium hyaluronate 0.1% in dry eye syndrome. Preservative-free sodium hyaluronate 0.1% eye drops can increase the effect of diquafosol 3% in dry eye syndrome.

  14. Modulation of the poly (ADP-ribose) polymerase inhibitor response and DNA recombination in breast cancer cells by drugs affecting endogenous wild-type p53.

    PubMed

    Ireno, Ivanildce Cristiane; Wiehe, Rahel Stephanie; Stahl, Andreea Iulia; Hampp, Stephanie; Aydin, Sevtap; Troester, Melissa A; Selivanova, Galina; Wiesmüller, Lisa

    2014-10-01

    Synthetic lethal interactions between poly (ADP-ribose) polymerase (PARP) and homologous recombination (HR) repair pathways have been exploited for the development of novel mono- and combination cancer therapies. The tumor suppressor p53 was demonstrated to exhibit indirect and direct regulatory activities in DNA repair, particularly in DNA double-strand break (DSB)-induced and replication-associated HR. In this study, we tested a potential influence of the p53 status on the response to PARP inhibition, which is known to cause replication stress. Silencing endogenous or inducibly expressing p53 we found a protective effect of p53 on PARP inhibitor (PARPi)-mediated cytotoxicities. This effect was specific for wild-type versus mutant p53 and observed in cancer but not in non-transformed cell lines. Enhanced cytotoxicities after treatment with the p53-inhibitory drug Pifithrinα further supported p53-mediated resistance to PARP inhibition. Surprisingly, we equally observed increased PARPi sensitivity in the presence of the p53-activating compound Nutlin-3. As a common denominator, both drug responses correlated with decreased HR activities: Pifithrinα downregulated spontaneous HR resulting in damage accumulation. Nutlin-3 induced a decrease of DSB-induced HR, which was accompanied by a severe drop in RAD51 protein levels. Thus, we revealed a novel link between PARPi responsiveness and p53-controlled HR activities. These data expand the concept of cell and stress type-dependent healer and killer functions of wild-type p53 in response to cancer therapeutic treatment. Our findings have implications for the individualized design of cancer therapies using PARPi and the potentially combined use of p53-modulatory drugs. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. 49 CFR 173.175 - Permeation devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., flat and horizontal surface from a height of 1.8 m (5.9 feet): (i) One drop flat on the bottom; (ii) One drop flat on the top; (iii) One drop flat on the long side; (iv) One drop flat on the short side... stacked to a height of 3 m (10 feet) (including the test sample). (3) Each of the above tests may be...

  16. Effect of carbon sources on the aggregation of photo fermentative bacteria induced by L-cysteine for enhancing hydrogen production.

    PubMed

    Xie, Guo-Jun; Liu, Bing-Feng; Ding, Jie; Wang, Qilin; Ma, Chao; Zhou, Xu; Ren, Nan-Qi

    2016-12-01

    Poor flocculation of photo fermentative bacteria resulting in continuous biomass washout from photobioreactor is a critical challenge to achieve rapid and stable hydrogen production. In this work, the aggregation of Rhodopseudomonas faecalis RLD-53 was successfully developed in a photobioreactor and the effects of different carbon sources on hydrogen production and aggregation ability were investigated. Extracellular polymeric substances (EPS) production by R. faecalis RLD-53 cultivated using different carbon sources were stimulated by addition of L-cysteine. The absolute ζ potentials of R. faecalis RLD-53 were considerably decreased with addition of L-cysteine, and aggregation barriers based on DLVO dropped to 15-43 % of that in control groups. Thus, R. faecalis RLD-53 flocculated effectively, and aggregation abilities of strain RLD-53 cultivated with acetate, propionate, lactate and malate reached 29.35, 32.34, 26.07 and 24.86 %, respectively. In the continuous test, hydrogen-producing activity was also promoted and reached 2.45 mol H 2 /mol lactate, 3.87 mol H 2 /mol propionate and 5.10 mol H 2 /mol malate, respectively. Therefore, the aggregation of R. faecalis RLD-53 induced by L-cysteine is independent on the substrate types, which ensures the wide application of this technology to enhance hydrogen recovery from wastewater dominated by different organic substrates.

  17. Predictors of Weapon Carrying in Youth Attending Drop-in Centers

    PubMed Central

    Blumberg, Elaine J.; Liles, Sandy; Kelley, Norma J.; Hovell, Melbourne F.; Bousman, Chad A.; Shillington, Audrey M.; Ji, Ming; Clapp, John

    2012-01-01

    Objective To test and compare 2 predictive models of weapon carrying in youth (n=308) recruited from 4 drop-in centers in San Diego and Imperial counties. Methods Both models were based on the Behavioral Ecological Model (BEM). Results The first and second models significantly explained 39% and 53% of the variance in weapon carrying, respectively, and both full models shared the significant predictors of being black(−), being Hispanic (−), peer modeling of weapon carrying/jail time(+), and school suspensions(+). Conclusions Results suggest that the BEM offers a generalizable conceptual model that may inform prevention strategies for youth at greatest risk of weapon carrying. PMID:19320622

  18. Promoting male partner HIV testing and safer sexual decision making through secondary distribution of self-tests by HIV-negative female sex workers and women receiving antenatal and post-partum care in Kenya: a cohort study.

    PubMed

    Thirumurthy, Harsha; Masters, Samuel H; Mavedzenge, Sue Napierala; Maman, Suzanne; Omanga, Eunice; Agot, Kawango

    2016-06-01

    Increased uptake of HIV testing by men in sub-Saharan Africa is essential for the success of combination prevention. Self-testing is an emerging approach with high acceptability, but little evidence exists on the best strategies for test distribution. We assessed an approach of providing multiple self-tests to women at high risk of HIV acquisition to promote partner HIV testing and to facilitate safer sexual decision making. In this cohort study, HIV-negative women aged 18-39 years were recruited at two sites in Kisumu, Kenya: a health facility with antenatal and post-partum clinics and a drop-in centre for female sex workers. Participants gave informed consent and were instructed on use of oral fluid based rapid HIV tests. Participants enrolled at the health facility received three self-tests and those at the drop-in centre received five self-tests. Structured interviews were conducted with participants at enrolment and over 3 months to determine how self-tests were used. Outcomes included the number of self-tests distributed by participants, the proportion of participants whose sexual partners used a self-test, couples testing, and sexual behaviour after self-testing. Between Jan 14, 2015, and March 13, 2015, 280 participants were enrolled (61 in antenatal care, 117 in post-partum care, and 102 female sex workers); follow-up interviews were completed for 265 (96%). Most participants with primary sexual partners distributed self-tests to partners: 53 (91%) of 58 participants in antenatal care, 91 (86%) of 106 in post-partum care, and 64 (75%) of 85 female sex workers. 82 (81%) of 101 female sex workers distributed more than one self-test to commercial sex clients. Among self-tests distributed to and used by primary sexual partners of participants, couples testing occurred in 27 (51%) of 53 in antenatal care, 62 (68%) of 91 from post-partum care, and 53 (83%) of 64 female sex workers. Among tests received by primary and non-primary sexual partners, two (4%) of 53 tests from participants in antenatal care, two (2%) of 91 in post-partum care, and 41 (14%) of 298 from female sex workers had positive results. Participants reported sexual intercourse with 235 (62%) of 380 sexual partners who tested HIV-negative, compared with eight (18%) of 45 who tested HIV-positive (p<0·0001); condoms were used in all eight intercourse events after positive results compared with 104 (44%) after of negative results (p<0·0018). Four participants reported intimate partner violence as a result of self-test distribution: two in the post-partum care group and two female sex workers. No other adverse events were reported. Provision of multiple HIV self-tests to women at high risk of HIV infection was successful in promoting HIV testing among their sexual partners and in facilitating safer sexual decisions. This novel strategy warrants further consideration as countries develop self-testing policies and programmes. Bill & Melinda Gates Foundation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Space Shuttle Solid Rocket Booster Decelerator Subsystem Drop Test 3 - Anatomy of a failure

    NASA Technical Reports Server (NTRS)

    Runkle, R. E.; Woodis, W. R.

    1979-01-01

    A test failure dramatically points out a design weakness or the limits of the material in the test article. In a low budget test program, with a very limited number of tests, a test failure sparks supreme efforts to investigate, analyze, and/or explain the anomaly and to improve the design such that the failure will not recur. The third air drop of the Space Shuttle Solid Rocket Booster Recovery System experienced such a dramatic failure. On air drop 3, the 54-ft drogue parachute was totally destroyed 0.7 sec after deployment. The parachute failure investigation, based on analysis of drop test data and supporting ground element test results is presented. Drogue design modifications are also discussed.

  20. 49 CFR 173.465 - Type A packaging tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... quarters of each rim from a height of 0.3 m (1 foot). (5) The target for the free drop test must be a flat... Transport Package mass Kilograms (pounds) Free drop distance Meters (Feet) 15,000 (33,000) Mass 0.3 (1) (2... section must be preceded by a free drop from a height of 0.3 m (1 foot) on each corner, or in the case of...

  1. Estimation of dynamic stability parameters from drop model flight tests

    NASA Technical Reports Server (NTRS)

    Chambers, J. R.; Iliff, K. W.

    1981-01-01

    A recent NASA application of a remotely-piloted drop model to studies of the high angle-of-attack and spinning characteristics of a fighter configuration has provided an opportunity to evaluate and develop parameter estimation methods for the complex aerodynamic environment associated with high angles of attack. The paper discusses the overall drop model operation including descriptions of the model, instrumentation, launch and recovery operations, piloting concept, and parameter identification methods used. Static and dynamic stability derivatives were obtained for an angle-of-attack range from -20 deg to 53 deg. The results of the study indicated that the variations of the estimates with angle of attack were consistent for most of the static derivatives, and the effects of configuration modifications to the model (such as nose strakes) were apparent in the static derivative estimates. The dynamic derivatives exhibited greater uncertainty levels than the static derivatives, possibly due to nonlinear aerodynamics, model response characteristics, or additional derivatives.

  2. Frog virus 3 ORF 53R, a putative myristoylated membrane protein, is essential for virus replication in vitro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitley, Dexter S.; Yu, Kwang; Sample, Robert C.

    2010-09-30

    Although previous work identified 12 complementation groups with possible roles in virus assembly, currently only one frog virus 3 protein, the major capsid protein (MCP), has been linked with virion formation. To identify other proteins required for assembly, we used an antisense morpholino oligonucleotide to target 53R, a putative myristoylated membrane protein, and showed that treatment resulted in marked reductions in 53R levels and a 60% drop in virus titers. Immunofluorescence assays confirmed knock down and showed that 53R was found primarily within viral assembly sites, whereas transmission electron microscopy detected fewer mature virions and, in some cells, dense granularmore » bodies that may represent unencapsidated DNA-protein complexes. Treatment with a myristoylation inhibitor (2-hydroxymyristic acid) resulted in an 80% reduction in viral titers. Collectively, these data indicate that 53R is an essential viral protein that is required for replication in vitro and suggest it plays a critical role in virion formation.« less

  3. Corneal thickness values before and after oxybuprocaine 0.4% eye drops.

    PubMed

    Asensio, Isabel; Rahhal, Saleh M; Alonso, Luis; Palanca-Sanfrancisco, José M; Sanchis-Gimeno, Juan A

    2003-08-01

    To determine changes in corneal thickness after topical anesthesia. Corneal thickness was measured before and 3 minutes after administration of two drops of oxybuprocaine 0.4% to 26 patients (26 eyes). We analyzed the corneal thickness of a control group, which was made up of 26 patients (26 eyes) before and 3 minutes after administration of two drops of saline solution. Corneal thickness was measured with the Orbscan Topography System II (Bausch Lomb Surg., Barcelona). Variations higher than +/- 10 microm were found following the instillation of 2 oxybuprocaine eye drops in eight eyes (30.76%) at the inferonasal cornea, in six eyes (23.08%) at the superotemporal, temporal and inferotemporal cornea, in five eyes (19.23%) at the nasal cornea, in three eyes (11.53%) at the central cornea, and in two eyes (7.69%) at the superonasal cornea. Nevertheless, no significant differences in the mean corneal thickness at each corneal location between the first and the second corneal thickness measurements were found in anesthetized eyes. Some individuals can present important increases and decreases in corneal thickness values after anesthetic eye drops. This effect of anesthetic eye drops must be considered by refractive surgeons when carrying out preoperative laser in situ keratomileusis corneal thickness measurements.

  4. 49 CFR 178.965 - Drop test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... Water/anti-freeze solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or... of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop test. (e) Drop... having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  5. 49 CFR 178.965 - Drop test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Water/anti-freeze solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or... of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop test. (e) Drop... having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  6. 49 CFR 178.965 - Drop test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... Water/anti-freeze solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or... of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop test. (e) Drop... having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  7. Kinetic Determinants of Reactive Strength in Highly Trained Sprint Athletes.

    PubMed

    Douglas, Jamie; Pearson, Simon; Ross, Angus; McGuigan, Mike

    2018-06-01

    Douglas, J, Pearson, S, Ross, A, and McGuigan, M. Kinetic determinants of reactive strength in highly trained sprint athletes. J Strength Cond Res 32(6): 1562-1570, 2018-The purpose of this study was to determine the braking and propulsive phase kinetic variables underpinning reactive strength in highly trained sprint athletes in comparison with a nonsprint-trained control group. Twelve highly trained sprint athletes and 12 nonsprint-trained participants performed drop jumps (DJs) from 0.25, 0.50, and 0.75 m onto a force plate. One familiarization session was followed by an experimental testing session within the same week. Reactive strength index (RSI), contact time, flight time, and leg stiffness were determined. Kinetic variables including force, power, and impulse were assessed within the braking and propulsive phases. Sprint-trained athletes demonstrated higher RSI vs. nonsprint-trained participants across all drop heights {3.02 vs. 2.02; ES (±90% confidence limit [CL]): 3.11 ± 0.86}. This difference was primarily attained by briefer contact times (0.16 vs. 0.22 seconds; effect size [ES]: -1.49 ± 0.53) with smaller differences observed for flight time (0.50 vs. 0.46 seconds; ES: 0.53 ± 0.58). Leg stiffness, braking and propulsive phase force, and power were higher in sprint-trained athletes. Very large differences were observed in mean braking force (51 vs. 38 N·kg; ES: 2.57 ± 0.73) which was closely associated with contact time (r ±90% CL: -0.93 ± 0.05). Sprint-trained athletes exhibited superior reactive strength than nonsprint-trained participants. This was due to the ability to strike the ground with a stiffer leg spring, an enhanced expression of braking force, and possibly an increased utilization of elastic structures. The DJ kinetic analysis provides additional insight into the determinants of reactive strength which may inform subsequent testing and training.

  8. Effects of acute change in salinity and moulting on the infection of white leg shrimp (Penaeus vannamei) with white spot syndrome virus upon immersion challenge.

    PubMed

    Van Thuong, K; Van Tuan, V; Li, W; Sorgeloos, P; Bossier, P; Nauwynck, H

    2016-12-01

    In the field, moulting and salinity drop in the water due to excessive rainfall have been mentioned to be risk factors for WSSV outbreaks. Therefore, in this study, the effect of an acute change in environmental salinity and shedding of the old cuticle shell on the susceptibility of Penaeus vannamei to WSSV was evaluated by immersion challenge. For testing the effect of abrupt salinity stress, early premoult shrimp that were acclimated to 35 g L -1 were subjected to salinities of 50 g L -1 , 35 g L -1 , 20 g L -1 , 10 g L -1 and 7 g L -1 or 5 g L -1 and simultaneously exposed to 10 5.5  SID 50 mL -1 of WSSV for 5 h, after which the salinity was brought back to 35 g L -1 . Shrimp that were transferred from 35 g L -1 to 50 g L -1 , 35 g L -1 and 20 g L -1 did not become infected with WSSV. Shrimp became infected with WSSV after an acute salinity drop from 35 g L -1 to 10 g L -1 and lower. The mortality in shrimp, subjected to a salinity change to 10 g L -1 , 7 g L -1 and 5 g L -1 , was 6.7%, 46.7% and 53.3%, respectively (P < 0.05) . For testing the effect of moulting, shrimp in early premoult, moulting and post-moult were immersed in sea water containing 10 5.5  SID 50 mL -1 of WSSV. The resulting mortality due to WSSV infection in shrimp inoculated during early premoult (0%), ecdysis (53.3%) and post-moult (26.72%) demonstrated that a significant difference exists in susceptibility of shrimp during the short moulting process (P < 0.05). The findings of this study indicate that during a drop in environmental salinity lower than 10 g L -1 and ecdysis, shrimp are at risk for a WSSV infection. These findings have important implications for WSSV control measures. © 2016 John Wiley & Sons Ltd.

  9. Enhancing Injury Protection Capabilities of Army Combat Helmets

    DTIC Science & Technology

    2006-11-01

    rate on each material’s energy attenuation characteristics, dynamic compression tests were conducted using a monorail drop tower conforming to ANSI...equipment. An Army combat helmet is fitted to the monorail drop tower (left). The variable weight, flat impactor (right) is fitted to the monorail ...3.3.1 Impact attenuation All impact tests were conducted using the USAARL vertical monorail drop tower (Figure 1, left). Impact sites along with

  10. Predictions of Helmet Pad Suspension System Performance using Isolated Pad Impact Results

    DTIC Science & Technology

    2010-09-13

    Equation 2 and Equation 3, respectively. 3. METHOD The primary method of data collection for this report is detailed in the 2008 Joint Live Fire ...tests and the helmet system tests (see Figure 3). All testing was performed with a monorail drop tower (see Figure 4) at three conditioning...right) and system test setup (right and center left) Figure 5. MEP monorail drop test setup with a hemispherical impactor (left and center left

  11. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Inspection and tests (modifies HG-500 through HG-540). 53.10-3 Section 53.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Tests, Inspection, Stamping, and Reporting (Article 5) § 53.10-3 Inspection and tests (modifies HG-500 through HG-540). (a)...

  12. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Inspection and tests (modifies HG-500 through HG-540). 53.10-3 Section 53.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Tests, Inspection, Stamping, and Reporting (Article 5) § 53.10-3 Inspection and tests (modifies HG-500 through HG-540). (a)...

  13. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Inspection and tests (modifies HG-500 through HG-540). 53.10-3 Section 53.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Tests, Inspection, Stamping, and Reporting (Article 5) § 53.10-3 Inspection and tests (modifies HG-500 through HG-540). (a)...

  14. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Inspection and tests (modifies HG-500 through HG-540). 53.10-3 Section 53.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Tests, Inspection, Stamping, and Reporting (Article 5) § 53.10-3 Inspection and tests (modifies HG-500 through HG-540). (a)...

  15. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Inspection and tests (modifies HG-500 through HG-540). 53.10-3 Section 53.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING HEATING BOILERS Tests, Inspection, Stamping, and Reporting (Article 5) § 53.10-3 Inspection and tests (modifies HG-500 through HG-540). (a)...

  16. Monitoring Changes In Power, Speed, Agility And Endurance In Elite Cricketers During The Off-Season.

    PubMed

    Bishop, Chris; Herridge, Ross; Turner, Anthony

    2017-06-22

    The purpose of this study was to monitor changes in power, speed, agility and endurance in elite cricketers during the 20-week off-season period. Fourteen elite male cricketers (age 26.2 ± 5.3years; height 180.8 ± 8.5cm; mass 83.5 ± 6.7kg) conducted a physical testing battery in week 1 and week 18 of the off-season period. The testing included a yoyo intermittent recovery test (yoyo IRT), bilateral and unilateral countermovement jumps (CMJ), squat jump (SJ), broad jump (BJ), drop jump (to calculate reactive strength index - [RSI]), pro agility and 5, 10, 20m sprint tests. Results showed significant improvements (p < 0.05) in all fitness tests except for the pro-agility test (p = 0.076), with effect sizes ranging from 0.26-2.8 across the test battery. The results of this study show the off-season in cricket allows adequate time for significant improvements of physical qualities needed for the demanding in-season schedule of the sport and provide normative values for an elite cricket population.

  17. Are the Stress Drops of Small Earthquakes Good Predictors of the Stress Drops of Larger Earthquakes?

    NASA Astrophysics Data System (ADS)

    Hardebeck, J.

    2017-12-01

    Uncertainty in PSHA could be reduced through better estimates of stress drop for possible future large earthquakes. Studies of small earthquakes find spatial variability in stress drop; if large earthquakes have similar spatial patterns, their stress drops may be better predicted using the stress drops of small local events. This regionalization implies the variance with respect to the local mean stress drop may be smaller than the variance with respect to the global mean. I test this idea using the Shearer et al. (2006) stress drop catalog for M1.5-3.1 events in southern California. I apply quality control (Hauksson, 2015) and remove near-field aftershocks (Wooddell & Abrahamson, 2014). The standard deviation of the distribution of the log10 stress drop is reduced from 0.45 (factor of 3) to 0.31 (factor of 2) by normalizing each event's stress drop by the local mean. I explore whether a similar variance reduction is possible when using the Shearer catalog to predict stress drops of larger southern California events. For catalogs of moderate-sized events (e.g. Kanamori, 1993; Mayeda & Walter, 1996; Boyd, 2017), normalizing by the Shearer catalog's local mean stress drop does not reduce the standard deviation compared to the unmodified stress drops. I compile stress drops of larger events from the literature, and identify 15 M5.5-7.5 earthquakes with at least three estimates. Because of the wide range of stress drop estimates for each event, and the different techniques and assumptions, it is difficult to assign a single stress drop value to each event. Instead, I compare the distributions of stress drop estimates for pairs of events, and test whether the means of the distributions are statistically significantly different. The events divide into 3 categories: low, medium, and high stress drop, with significant differences in mean stress drop between events in the low and the high stress drop categories. I test whether the spatial patterns of the Shearer catalog stress drops can predict the categories of the 15 events. I find that they cannot, rather the large event stress drops are uncorrelated with the local mean stress drop from the Shearer catalog. These results imply that the regionalization of stress drops of small events does not extend to the larger events, at least with current standard techniques of stress drop estimation.

  18. Acute Effects of Drop-Jump Protocols on Explosive Performances of Elite Handball Players.

    PubMed

    Dello Iacono, Antonio; Martone, Domenico; Padulo, Johnny

    2016-11-01

    Dello Iacono, A, Martone, D, and Padulo, J. Acute effects of drop-jump protocols on explosive performances of elite handball players. J Strength Cond Res 30(11): 3122-3133, 2016-This study aimed to assess the acute effects of vertical and horizontal drop jump-based postactivation potentiation (PAP) protocols on neuromuscular abilities in tasks such as jumping, sprinting, and change of direction (COD). Eighteen handball players were assessed before and after PAP regimens, consisting of either vertical single-leg drop-jumps (VDJ) or horizontal single-leg drop-jumps (HDJ) single-leg drop-jumps, on countermovement jump (CMJ), linear sprint, shuttle sprint, and agility performance. The HDJ led to greater improvement of the COD performance in comparison with the VDJ (-6.8 vs. -1.3%; p ≤ 0.05), whereas the VDJ caused greater improvement in the CMJ task compared with the HDJs (+6.5 vs. +1%; p ≤ 0.05). Moreover, the VDJ regimens compared with HDJ induced greater changes in most of the kinetic variables associated with vertical jumping performance, such as peak ground reaction forces (+9.6 vs. +1.3%), vertical displacement (-13.4 vs. -5.3%), leg-spring stiffness (+18.6 vs. +3.6%), contact time (-9.2 vs. -1.3%), and reactive strength index (+7.3 vs. +2.4%) (all comparisons with p ≤ 0.05). Conversely, the HDJ regimens were able to improve the COD performance only by reducing the contact time on COD more than the VDJ (-13.3 vs. -2.4% with p ≤ 0.05). The results showed that both PAPs were able to improve the performances that specifically featured similar force-orientation production. This investigation showed the crucial role that different and specific PAP regimens play in optimizing related functional performances. Specifically oriented vertical and horizontal single-leg drop-jump protocols represent viable means for achieving enhanced explosive-based tasks such as jumping and COD.

  19. Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula.

    PubMed

    Hull, Jeffrey E; Balakin, Boris V; Kellerman, Brad M; Wrolstad, David K

    2013-07-01

    The goal of this research was to compare side-to-side (STS) and end-to-side (ETS) anastomoses in a computer model of the arteriovenous fistula with computational fluid dynamic analysis. A matrix of 17 computer arteriovenous fistula models (SolidWorks, Dassault Systèmes, France) of artery-vein pairs (3-mm-diameter artery + 3-mm-diameter vein and 4-mm-diameter artery +6-mm-diameter vein elliptical anastomoses) in STS, 45° ETS, and 90° ETS configurations with cross-sectional areas (CSAs) of 3.5 to 18.8 mm(2) were evaluated with computational fluid dynamic software (STAR-CCM+; CD-adapco, Melville, NY) in simulations at defined flow rates from 600 to 1200 mL/min and mean arterial pressures of 50 to 140 mm Hg. Models and configurations were evaluated for pressure drop across the anastomosis, arterial inflow, venous outflow, arterial outflow, velocity vector, and wall shear stress (WSS) profile. Pressure drop across the anastomosis was inversely proportional to anastomotic CSA and to venous outflow and was proportional to arterial inflow. Pressure drop was greater in 3 + 3 models than in 4 + 6 STS models; 90° ETS configurations had the lowest pressure drops and were nearly identical, whereas 45° ETS configurations had the highest pressure drops. Venous outflow in the 4 + 6 model in STS configurations, evaluated at 100 mm Hg arterial inflow pressure, was 390, 592, 610, and 886 mL/min in anastomotic CSAs of 3.5, 5.3, 7.1, and 18.8 mm(2), respectively, and was similar in 90° ETS (609 and 908 mL/min) and lower in 45° ETS (534 and 562 mL/min) configurations at CSAs of 5.3 and 18.8 mm(2). The mean increase in venous outflow was 69 mL/min (range, -59 to 134) between 3 + 3 and 4 + 6 models at 100 mm Hg arterial inflow. The most uniform WSS profile occurs in STS anastomoses followed by 45° ETS and then 90° ETS anastomoses. The STS and 90° ETS anastomoses have high venous outflow and a tendency toward reversed arterial outflow. The 45° ETS anastomosis has reduced venous outflow but resists reversed arterial outflow. The STS anastomosis has more uniform WSS characteristics compared with the 45° and 90° ETS anastomoses. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  20. Superconductivity and weak localization of PdxBi2Se3 whiskers at low temperatures

    NASA Astrophysics Data System (ADS)

    Druzhinin, Anatoly; Ostrovskii, Igor; Khoverko, Yuriy; Rogacki, Krzysztof; Liakh-Kaguy, Natalia

    2018-02-01

    The temperature dependencies of Bi2Se3 whiskers' resistance with Pd doping concentration of (1÷2)×1019 cm-3 where measured in the temperature range 1.5÷77 K. At temperature 5.3 K a sharp drop in the whisker resistance was found. The observed effect is likely connected with the contribution of two processes such as the electron localization and superconductivity at temperatures below 5.3 K. The magnetoresistance in the n-type conductivity Bi2Se3 whiskers with different doping concentration of palladium that correspond to metal side of the metal-insulator transition was studied at low temperatures and magnetic field 0÷10 T. The whisker magnetoconductance is considered in the framework of the weak antilocalization model and connected with subsurface layers of Bi2Se3 whiskers.

  1. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2012-07-01 2012-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  2. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 5 2011-07-01 2011-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  3. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2014-07-01 2014-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  4. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2013-07-01 2013-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  5. Repeatability of a dynamic rollover test system.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2016-08-17

    The goal of this study was to characterize the rollover crash and to evaluate the repeatability of the Dynamic Rollover Test System (DRoTS) in terms of initial roof-to-ground contact conditions, vehicle kinematics, road reaction forces, and vehicle deformation. Four rollover crash tests were performed on 2 pairs of replicate vehicles (2 sedan tests and 2 compact multipurpose van [MPV] tests), instrumented with a custom inertial measurement unit to measure vehicle and global kinematics and string potentiometers to measure pillar deformation time histories. The road was instrumented with load cells to measure reaction loads and an optical encoder to measure road velocity. Laser scans of pre- and posttest vehicles were taken to provide detailed deformation maps. Initial conditions were found to be repeatable, with the largest difference seen in drop height of 20 mm; roll rate, roll angle, pitch angle, road velocity, drop velocity, mass, and moment of inertia were all 7% different or less. Vehicle kinematics (roll rate, road speed, roll and pitch angle, global Z' acceleration, and global Z' velocity) were similar throughout the impact; however, differences were seen in the sedan tests because of a vehicle fixation problem and differences were seen in the MPV tests due to an increase in reaction forces during leading side impact likely caused by disparities in roll angle (3° difference) and mass properties (2.2% in moment of inertia [MOI], 53.5 mm difference in center of gravity [CG] location). Despite those issues, kinetic and deformation measures showed a high degree of repeatability, which is necessary for assessing injury risk in rollover because roof strength positively correlates with injury risk (Brumbelow 2009). Improvements of the test equipment and matching mass properties will ensure highly repeatable initial conditions, vehicle kinematics, kinetics, and deformations.

  6. The Influence of Aerosols on the Shortwave Cloud Radiative Forcing from North Pacific Oceanic Clouds: Results from the Cloud Indirect Forcing Experiment (CIFEX)

    NASA Technical Reports Server (NTRS)

    Wilcox, Eric M.; Roberts, Greg; Ramanathan, V.

    2006-01-01

    Aerosols over the Northeastern Pacific Ocean enhance the cloud drop number concentration and reduce the drop size for marine stratocumulus and cumulus clouds. These microphysical effects result in brighter clouds, as evidenced by a combination of aircraft and satellite observations. In-situ measurements from the Cloud Indirect Forcing Experiment (CIFEX) indicate that the mean cloud drop number concentration in low clouds over the polluted marine boundary layer is greater by 53/cu cm compared to clean clouds, and the mean cloud drop effective radius is smaller by 4 microns. We link these in-situ measurements of cloud modification by aerosols, for the first time, with collocated satellite broadband radiative flux observations from the Clouds and the Earth's Radiant Energy System (CERES) to show that these microphysical effects of aerosols enhance the top-of-atmosphere cooling by -9.9+/-4.3 W/sq m for overcast conditions.

  7. Comparative clinical trial of topical anesthetic agents in cataract surgery: lidocaine 2% gel, bupivacaine 0.5% drops, and benoxinate 0.4% drops.

    PubMed

    Soliman, Mahmoud M; Macky, Tamer A; Samir, M Khaled

    2004-08-01

    To assess the efficacy of lidocaine gel, bupivacaine drops, and benoxinate drops as topical anesthetic agents in cataract surgery. Kasr El-Aini Hospital, Cairo University, Cairo, Egypt. This prospective randomized study comprised 90 patients scheduled for routine cataract extraction. Patients were randomized into 3 groups of 30 each based on which anesthetic agent they received: lidocaine 2% gel, bupivacaine 0.5% drops, or benoxinate 0.4% drops. Subjective pain at application of the agent and intraoperatively was quantified by the patients using a verbal pain score (VPS) scale from 0 to 10. The duration of discomfort at application, duration of surgery, rate of supplemental sub-Tenon's anesthesia, and complications were recorded. The mean VPS at application was 2.97, 1.53, and 1.03 in the lidocaine, bupivacaine, and benoxinate groups, respectively; the VPS in the lidocaine group was statistically significantly higher than in the other 2 groups (P<.001). The mean duration of pain at application was 25 seconds, 14 seconds, and 6 seconds in the lidocaine, bupivacaine, and benoxinate groups, respectively, and was statistically significantly higher in the lidocaine group (P<.001). The mean VPS during surgery was 1.6, 4.1, and 7.1 in the lidocaine, bupivacaine, and benoxinate groups; the lidocaine group had a statistically significantly lower mean VPS than the other 2 groups (P<.001). The incidence of supplemental sub-Tenon's injection was 3.3%, 10.0%, and 73.3%, respectively, and was statistically significantly lower in the lidocaine and bupivacaine groups than in the benoxinate group (P<.001). The patients' overall satisfaction was statistically significantly higher in the lidocaine and bupivacaine groups than in the benoxinate group (93.3%, 83.3%, and 33.3%, respectively) (P<.001). Three patients in the lidocaine group had corneal haze at the time of surgery, which was not statistically significant (P>.1). Lidocaine gel was a better topical anesthetic agent than bupivacaine and benoxinate drops. Bupivacaine drops were effective in providing deep topical anesthesia.

  8. Nocturnal hypothermia impairs flight ability in birds: a cost of being cool

    PubMed Central

    Carr, Jennie M.; Lima, Steven L.

    2013-01-01

    Many birds use regulated drops in night-time body temperature (Tb) to conserve energy critical to winter survival. However, a significant degree of hypothermia may limit a bird's ability to respond to predatory attack. Despite this likely energy–predation trade-off, the behavioural costs of avian hypothermia have yet to be examined. We thus monitored the nocturnal hypothermia of mourning doves (Zenaida macroura) in a laboratory setting in response to food deprivation. Nocturnal flight tests were used to quantify the flight ability of hypothermic doves. Many hypothermic doves (39% of tests) could not fly while carrying a small weight, but could do so after quickly warming up to typical daytime Tb. Doves that were unable to fly during their first test were more hypothermic than those that could fly, with average Tb reductions of 5.3°C and 3.3°C, respectively, but there was no overall indication of a threshold Tb reduction beyond which doves were consistently incapable of flight. These results suggest that energy-saving hypothermia interferes with avian antipredator behaviour via a reduction in flight ability, likely leading to a trade-off between energy-saving hypothermia and the risk of predation. PMID:24107528

  9. Noncontact surface tension and viscosity measurements of molten oxides with a pressurized hybrid electrostatic-aerodynamic levitator

    NASA Astrophysics Data System (ADS)

    Ishikawa, Takehiko; Yu, Jianding; Paradis, Paul-François

    2006-05-01

    In order to measure the surface tension and the viscosity of molten oxides, the oscillation drop technique has been applied on a pressurized hybrid electrostatic-aerodynamic levitator. To suppress the electrical discharge between the top and bottom electrodes, the drop excitation method which has been used with high vacuum electrostatic levitators has been modified. As a demonstration, the surface tension and viscosity of liquid BaTiO3 were measured using this new method. Over the 1500-2000K interval, the surface tension was measured as γ(T )=349-0.03 (T-Tm) (10-3N/m), where Tm=1893K is the melting temperature. Similarly, the viscosity was determined as η(T )=0.53exp[5.35×104/(RT)](10-3Pas) over the same temperature interval.

  10. 40 CFR Table 2 to Subpart Kkkkk of... - Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Maintain the average scrubber pressure drop for each 3-hour block period at or above the average pressure drop established during the performance test; andb. Maintain the average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test...

  11. The structure of evaporating and combusting sprays: Measurements and predictions

    NASA Technical Reports Server (NTRS)

    Shuen, J. S.; Solomon, A. S. P.; Faeth, G. M.

    1984-01-01

    An apparatus developed, to allow observations of monodisperse sprays, consists of a methane-fueled turbulent jet diffusion flame with monodisperse methanol drops injected at the burner exit. Mean and fluctuating-phase velocities, drop sizes, drop-mass fluxes and mean-gas temperatures were measured. Initial drop diameters of 100 and 180 microns are being considered in order to vary drop penetration in the flow and effects of turbulent dispersion. Baseline tests of the burner flame with no drops present were also conducted. Calibration tests, needed to establish methods for predicting drop transport, involve drops supported in the post-flame region of a flat-flame burner operated at various mixture ratios. Spray models which are being evaluated include: (1) locally homogeneous flow (LFH) analysis, (2) deterministic separated flow (DSF) analysis and (3) stochastic separated flow (SSF) analysis.

  12. A study of Guptkashi, Uttarakhand earthquake of 6 February 2017 ( M w 5.3) in the Himalayan arc and implications for ground motion estimation

    NASA Astrophysics Data System (ADS)

    Srinagesh, Davuluri; Singh, Shri Krishna; Suresh, Gaddale; Srinivas, Dakuri; Pérez-Campos, Xyoli; Suresh, Gudapati

    2018-05-01

    The 2017 Guptkashi earthquake occurred in a segment of the Himalayan arc with high potential for a strong earthquake in the near future. In this context, a careful analysis of the earthquake is important as it may shed light on source and ground motion characteristics during future earthquakes. Using the earthquake recording on a single broadband strong-motion seismograph installed at the epicenter, we estimate the earthquake's location (30.546° N, 79.063° E), depth ( H = 19 km), the seismic moment ( M 0 = 1.12×1017 Nm, M w 5.3), the focal mechanism ( φ = 280°, δ = 14°, λ = 84°), the source radius ( a = 1.3 km), and the static stress drop (Δ σ s 22 MPa). The event occurred just above the Main Himalayan Thrust. S-wave spectra of the earthquake at hard sites in the arc are well approximated (assuming ω -2 source model) by attenuation parameters Q( f) = 500 f 0.9, κ = 0.04 s, and f max = infinite, and a stress drop of Δ σ = 70 MPa. Observed and computed peak ground motions, using stochastic method along with parameters inferred from spectral analysis, agree well with each other. These attenuation parameters are also reasonable for the observed spectra and/or peak ground motion parameters in the arc at distances ≤ 200 km during five other earthquakes in the region (4.6 ≤ M w ≤ 6.9). The estimated stress drop of the six events ranges from 20 to 120 MPa. Our analysis suggests that attenuation parameters given above may be used for ground motion estimation at hard sites in the Himalayan arc via the stochastic method.

  13. A study of Guptkashi, Uttarakhand earthquake of 6 February 2017 (M w 5.3) in the Himalayan arc and implications for ground motion estimation

    NASA Astrophysics Data System (ADS)

    Srinagesh, Davuluri; Singh, Shri Krishna; Suresh, Gaddale; Srinivas, Dakuri; Pérez-Campos, Xyoli; Suresh, Gudapati

    2018-02-01

    The 2017 Guptkashi earthquake occurred in a segment of the Himalayan arc with high potential for a strong earthquake in the near future. In this context, a careful analysis of the earthquake is important as it may shed light on source and ground motion characteristics during future earthquakes. Using the earthquake recording on a single broadband strong-motion seismograph installed at the epicenter, we estimate the earthquake's location (30.546° N, 79.063° E), depth (H = 19 km), the seismic moment (M 0 = 1.12×1017 Nm, M w 5.3), the focal mechanism (φ = 280°, δ = 14°, λ = 84°), the source radius (a = 1.3 km), and the static stress drop (Δσ s 22 MPa). The event occurred just above the Main Himalayan Thrust. S-wave spectra of the earthquake at hard sites in the arc are well approximated (assuming ω -2 source model) by attenuation parameters Q(f) = 500f 0.9, κ = 0.04 s, and f max = infinite, and a stress drop of Δσ = 70 MPa. Observed and computed peak ground motions, using stochastic method along with parameters inferred from spectral analysis, agree well with each other. These attenuation parameters are also reasonable for the observed spectra and/or peak ground motion parameters in the arc at distances ≤ 200 km during five other earthquakes in the region (4.6 ≤ M w ≤ 6.9). The estimated stress drop of the six events ranges from 20 to 120 MPa. Our analysis suggests that attenuation parameters given above may be used for ground motion estimation at hard sites in the Himalayan arc via the stochastic method.

  14. 49 CFR 178.603 - Drop test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (using the fourth sample). Fifth drop: On a corner (using the fifth sample). Bags—single-ply with a side... samples). Bags—single-ply without a side seam, or multi-ply Three—(two drops per bag) First drop: Flat on... the drum is no longer sift-proof; (3) For a bag, neither the outermost ply nor an outer packaging...

  15. SU-F-T-279: Impact of Beam Energy Drifts On IMRT Delivery Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goddu, S; Kamal, G; Herman, A

    Purpose: According to TG-40 percent-depth-dose (PDD) tolerance is ±2% but TG-142 is ±1%. Now the question is, which one is relevant in IMRT era? The primary objective of this study is to evaluate dosimetric impact of beam-energy-drifts on IMRT-delivery. Methods: Beam-energy drifts were simulated by adjusting Linac’s bending-magnet-current (BMC) followed by tuning the pulse-forming network and adjusting gun-current. PDD change of −0.6% and +1.2% were tested. Planar-dosimetry measurements were performed using an ionization-chamber-array in solid-water phantoms. Study includes 10-head-and-neck and 3-breast cancer patients. en-face beam-deliveries were also tested at 1.3cm and 5.3cm depths. Composite and single-field dose-distributions were compared againstmore » the plans to determine %Gamma pass-rates (%GPRs). For plan dose comparisons, changes in %Gamma pass-rates (cPGPRs) were computed/reported to exclude the differences between dose-computation and delivery. Dose distributions of the drifted-energies were compared against their baseline measurements to determine the% GPRs. A Gamma criteria of 3%/3mm was considered for plan-dose comparisons while 3%/1mm used for measured dose intercomparisons. Results: For composite-dose delivery, average cPGPRs were 0.41%±2.48% and −2.54%±3.65% for low-energy (LE) and high-energy (HE) drifts, respectively. For measured dose inter-comparisons, the average%GPRs were 98.4%±2.2% (LE-drift) and 95.8%±4.0 (HE-drift). The average %GPR of 92.6%±4.3% was noted for the worst-case scenario comparing LE-drift to HE-drift. All en-face beams at 5.3 cm depth have cPGPRs within ±4% of the baseline-energy measurements. However, greater variations were noted for 1.3cm depth. Average %GPRs for drifted energies were >99% at 5.3cm and >97% at 1.3cm depths. However, for the worst-case scenario (LE-drift to HE-drift) these numbers dropped to 95.2% at 5.3cm and 93.1% at 1.3cm depths. Conclusion: The dosimetric impact of beam-energy drifts was found to be within clinically acceptable tolerance. However, this study includes a single energy with limited range of PDD change. Further studies are on going and the results will be presented. Received funding from Varian Medical Systems, Palo Alto, CA.« less

  16. Analysis of a p53 Mutation Associated with Cancer Susceptibility for Biochemistry and Genetic Laboratory Courses

    ERIC Educational Resources Information Center

    Soto-Cruz, Isabel; Legorreta-Herrera, Martha

    2009-01-01

    We have devised and implemented a module for an upper division undergraduate laboratory based on the amplification and analysis of a p53 polymorphism associated with cancer susceptibility. First, students collected a drop of peripheral blood cells using a sterile sting and then used FTA cards to extract the genomic DNA. The p53 region is then PCR…

  17. Investigation of the quality of stored red blood cells after simulated air drop in the maritime environment.

    PubMed

    Meli, Athinoula; Hancock, Vicky; Doughty, Heidi; Smedley, Steve; Cardigan, Rebecca; Wiltshire, Michael

    2018-02-01

    Maritime medical capability may be compromised by blood resupply. Air-dropped red blood cells (RBCs) is a possible mitigation factor. This study set out to evaluate RBC storage variables after a simulated parachute air drop into the sea, as limited data exist. The air load construction for the air drop of blood was subject to static drop assessment to simulate a worst-case parachute drop scenario. One control and two test Golden Hour shipping containers were each packaged with 10 RBC units. The control box was not dropped; Test Boxes 1 and 2 were further reinforced with waterproof boxes and underwent a simulated air drop on Day 7 or Day 8 postdonation, respectively. One day after the drop and once a week thereafter until Day 43 of storage, RBCs from each box were sampled and tested for full blood counts, hemolysis, adenosine triphosphate, 2,3-diphosphoglycerate, pH, extracellular potassium, glucose, lactate, deformability, and RBC microvesicles. The packaging configuration completed the air drop with no water ingress or physical damage. All units met UK specifications for volume, hemoglobin, and hemolysis. There were no significant differences for any of the variables studied between RBCs in the control box compared to RBCs in Test Boxes 1 and 2 combined over storage. The test proved that the packaging solution and the impact of a maritime air drop as performed in this study, on Day 7 or Day 8 postdonation, did not affect the in vitro quality of RBCs in SAGM over storage for 35 days. © 2017 AABB.

  18. Haemophilia & Exercise Project (HEP): the impact of 1-year sports therapy programme on physical performance in adult haemophilia patients.

    PubMed

    Czepa, D; von Mackensen, S; Hilberg, T

    2013-03-01

    Episodes of bleeding in people with haemophilia (PWH) are associated with reduced activity and limitations in physical performance. Within the scope of the 'Haemophilia & Exercise Project' (HEP) PWH were trained in a sports therapy programme. Aim of this study was to investigate subjective and objective physical performance in HEP-participants after 1 year training. Physical performance of 48 adult PWH was compared before and after sports therapy subjectively (HEP-Test-Q) and objectively regarding mobility (range of motion), strength and coordination (one-leg-stand) and endurance (12-min walk test). Sports therapy included an independent home training that had previously been trained in several collective sports camps. Forty-three controls without haemophilia and without training were compared to PWH. Of 48 PWH, 13 performed a regular training (active PWH); 12 HEP-participants were constantly passive (passive PWH). Twenty-three PWH and 24 controls dropped out because of incomplete data. The activity level increased by 100% in active PWH and remained constant in passive PWH, and in controls (P ≤ 0.05). Only mobility of the right knee was significantly improved in active PWH (+5.8 ± 5.3°) compared to passive PWH (-1.3 ± 8.6°). The 12-min walk test proved a longer walking distance for active PWH (+217 ± 199 m) compared to controls (-32 ± 217 m). Active PWH reported a better subjective physical performance in the HEP-Test-Q domains 'strength & coordination', 'endurance' and in the total score (+9.4 ± 13.8) compared to passive PWH (-5.3 ± 13.5) and controls (+3.7 ± 7.5). The 'mobility'-scale and one-leg-stand remained unchanged. Sports therapy increases the activity level and physical performance of PWH, whereby objective effects do not always correspond with subjective assessments. © 2012 Blackwell Publishing Ltd.

  19. 40 CFR Table B-3 to Subpart B of... - Interferent Test Concentration, Parts per Million

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... per Million B Table B-3 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION..., Subpt. B, Table B-3 Table B-3 to Subpart B of Part 53—Interferent Test Concentration, Parts per Million Table B-3 to Subpart B of Part 53—Interferent Test Concentration,1 Parts per Million Pollutant Analyzer...

  20. Reusable Material for Drop Tower

    DTIC Science & Technology

    2011-08-01

    R3 Buna-N Rubber ............................................................................................... 32 B-3. R5 EPDM Rubber ...Butyl Rubber . Figure B-2. R3 Buna-N Rubber . Figure B-3. R5 EPDM Rubber . Figure B-4. R6 Gel Rubber . UNCLASSIFIED 33...11 Current Drop Tower Material & Setup .......................................................... 11 Bowling Ball Rubber Material Sample Test

  1. 40 CFR 53.21 - Test conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test conditions. 53.21 Section 53.21... Methods SO2, CO, O3, and NO2 § 53.21 Test conditions. (a) Set-up and start-up of the test analyzer shall... before beginning the tests. The test procedures assume that the test analyzer has an analog measurement...

  2. 40 CFR 53.21 - Test conditions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test conditions. 53.21 Section 53.21... Methods for SO2, CO, O3, and NO2 § 53.21 Test conditions. (a) Set-up and start-up of the test analyzer... before beginning the tests. The test procedures assume that the test analyzer has a conventional analog...

  3. Detection of antibodies against hepatitis A in blood spots dried on filter paper. Is this a reliable method for epidemiological studies?

    PubMed Central

    Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.

    1997-01-01

    Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596

  4. Static, Drop, and Flight Tests on Musselman Type Airwheels

    NASA Technical Reports Server (NTRS)

    Peck, William C; Beard, Albert P

    1932-01-01

    The purpose of this investigation was to obtain quantitative information on the shock-reducing and energy-dissipating qualities of a set of 30 by 13-6 Musselman type airwheels. The investigation consisted of static, drop, and flight tests. The static tests were made with inflation pressures of approximately 0, 5, 10, 15, 20, and 25 pounds per square inch and loadings up to 9,600 pounds. The drop tests were with the inflation pressures approximately 5, 10, 15, 20, and 25 pounds per square inch and loadings of 1,840, 2,440, 3,050, and 3,585 pounds. The flight tests were made with VE-7 airplane weighing 2,153 pounds, with the tires inflated to 5, 10, and 15 pounds per square inch. The landing gears used in conjunction with airwheels were practically rigid structures. The results of the tests showed that the walls of the tires carried a considerable portion of the load, each tire supporting a load of 600 pounds with a depression of approximately 6 inches. The shock-reducing qualities, under severe tests, and the energy dissipating characteristics of the tires, under all tests, were poor. The latter was evidenced by the rebound present in all landings made. In the severe drop tests, the free rebound reached as much as 60 per cent of the free drop. The results indicate that a shock-reducing and energy-dissipating mechanism should be used in conjunction with airwheels.

  5. Response of an Impact Test Apparatus for Fall Protective Headgear Testing Using a Hybrid-III Head/Neck Assembly

    PubMed Central

    Caccese, V.; Ferguson, J.; Lloyd, J.; Edgecomb, M.; Seidi, M.; Hajiaghamemar, M.

    2017-01-01

    A test method based upon a Hybrid-III head and neck assembly that includes measurement of both linear and angular acceleration is investigated for potential use in impact testing of protective headgear. The test apparatus is based upon a twin wire drop test system modified with the head/neck assembly and associated flyarm components. This study represents a preliminary assessment of the test apparatus for use in the development of protective headgear designed to prevent injury due to falls. By including angular acceleration in the test protocol it becomes possible to assess and intentionally reduce this component of acceleration. Comparisons of standard and reduced durometer necks, various anvils, front, rear, and side drop orientations, and response data on performance of the apparatus are provided. Injury measures summarized for an unprotected drop include maximum linear and angular acceleration, head injury criteria (HIC), rotational injury criteria (RIC), and power rotational head injury criteria (PRHIC). Coefficient of variation for multiple drops ranged from 0.4 to 6.7% for linear acceleration. Angular acceleration recorded in a side drop orientation resulted in highest coefficient of variation of 16.3%. The drop test apparatus results in a reasonably repeatable test method that has potential to be used in studies of headgear designed to reduce head impact injury. PMID:28216804

  6. Improving the rainfall rate estimation in the midstream of the Heihe River Basin using rain drop size distribution

    NASA Astrophysics Data System (ADS)

    Zhao, G.; Chu, R.; Li, X.; Zhang, T.; Shen, J.; Wu, Z.

    2009-09-01

    During the intensive observation period of the Watershed Allied Telemetry Experimental Research (WATER), a total of 1074 raindrop size distribution were measured by the Parsivel disdrometer, a latest state of the art optical laser instrument. Because of the limited observation data in Qinghai-Tibet Plateau, the modeling behavior was not well-done. We used raindrop size distributions to improve the rain rate estimator of meteorological radar, in order to obtain many accurate rain rate data in this area. We got the relationship between the terminal velocity of the rain drop and the diameter (mm) of a rain drop: v(D)=4.67 D0.53. Then four types of estimators for X-band polarimetric radar are examined. The simulation results show that the classical estimator R(Z) is most sensitive to variations in DSD and the estimator R (KDP, Z, ZDR) is the best estimator for estimating the rain rate. The lowest sensitivity of the rain rate estimator R (KDP, Z, ZDP) to variations in DSD can be explained by the following facts. The difference in the forward-scattering amplitudes at horizontal and vertical polarizations, which contributes KDP, is proportional to the 3rd power of the drop diameter. On the other hand, the exponent of the backscatter cross section, which contributes to Z, is proportional to the 6th power of the drop diameter. Because the rain rate R is proportional to the 3.57th power of the drop diameter, KDP is less sensitive to DSD variations than Z.

  7. Football helmet drop tests on different fields using an instrumented Hybrid III head.

    PubMed

    Viano, David C; Withnall, Chris; Wonnacott, Michael

    2012-01-01

    An instrumented Hybrid III head was placed in a Schutt ION 4D football helmet and dropped on different turfs to study field types and temperature on head responses. The head was dropped 0.91 and 1.83 m giving impacts of 4.2 and 6.0 m/s on nine different football fields (natural, Astroplay, Fieldturf, or Gameday turfs) at turf temperatures of -2.7 to 23.9 °C. Six repeat tests were conducted for each surface at 0.3 m (1') intervals. The Hybrid III was instrumented with triaxial accelerometers to determine head responses for the different playing surfaces. For the 0.91-m drops, peak head acceleration varied from 63.3 to 117.1 g and HIC(15) from 195 to 478 with the different playing surfaces. The lowest response was with Astroplay, followed by the engineered natural turf. Gameday and Fieldturf involved higher responses. The differences between surfaces decreased in the 1.83 m tests. The cold weather testing involved higher accelerations, HIC(15) and delta V for each surface. The helmet drop test used in this study provides a simple and convenient means of evaluating the compliance and energy absorption of football playing surfaces. The type and temperature of the playing surface influence head responses.

  8. 49 CFR 178.810 - Drop test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... preparation for the drop test. (1) Metal, rigid plastic, and composite IBCs intended to contain solids must be.... (4) Rigid plastic IBCs and composite IBCs with plastic inner receptacles must be conditioned for... material having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  9. High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array.

    PubMed

    Tung, Yi-Chung; Hsiao, Amy Y; Allen, Steven G; Torisawa, Yu-suke; Ho, Mitchell; Takayama, Shuichi

    2011-02-07

    Culture of cells as three-dimensional (3D) aggregates can enhance in vitro tests for basic biological research as well as for therapeutics development. Such 3D culture models, however, are often more complicated, cumbersome, and expensive than two-dimensional (2D) cultures. This paper describes a 384-well format hanging drop culture plate that makes spheroid formation, culture, and subsequent drug testing on the obtained 3D cellular constructs as straightforward to perform and adapt to existing high-throughput screening (HTS) instruments as conventional 2D cultures. Using this platform, we show that drugs with different modes of action produce distinct responses in the physiological 3D cell spheroids compared to conventional 2D cell monolayers. Specifically, the anticancer drug 5-fluorouracil (5-FU) has higher anti-proliferative effects on 2D cultures whereas the hypoxia activated drug commonly referred to as tirapazamine (TPZ) are more effective against 3D cultures. The multiplexed 3D hanging drop culture and testing plate provides an efficient way to obtain biological insights that are often lost in 2D platforms.

  10. 40 CFR 53.21 - Test conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test conditions. 53.21 Section 53.21... Methods SO2, CO, O3, and NO2 § 53.21 Test conditions. (a) Set-up and start-up of the test analyzer shall... before beginning the tests. If the candidate method does not include an integral strip chart recorder...

  11. Preventing exercise-induced hypoglycemia in type 1 diabetes using real-time continuous glucose monitoring and a new carbohydrate intake algorithm: an observational field study.

    PubMed

    Riddell, Michael C; Milliken, Jill

    2011-08-01

    Real-time (RT) continuous glucose monitoring (CGM) offers the possibility to better manage glucose levels during exercise in active individuals with type 1 diabetes mellitus (T1DM). However, studies have yet to determine the appropriate actions to take when glucose levels are trending toward hypoglycemia. The purpose of this observational field study was to test the effectiveness of RT-GCM and a new carbohydrate intake algorithm designed for maintaining euglycemia during sports. During a 2-week sports camp, 25 adolescents (8-17 years old) with T1DM were fitted with a RT-CGM device and instructed to ingest fast-acting carbohydrates (8-20 g, depending on the concentration of glucose at the time of RT-CGM alert and rates of change in glycemia) when glucose levels were trending toward hypoglycemia. Rates of change in glucose were measured before and after algorithm use, and the incidence of hypoglycemia was documented. With RT-CGM and algorithm use, euglycemia was largely maintained with modest amounts of carbohydrate intake, even when glucose levels were initially dropping at an elevated rate (>0.55 mmol/L per 5 min). Mild biochemical hypoglycemia (3.0-3.9 mmol/L) occurred just twice out of 22 uses of the algorithm (9%) when trend arrows alerted the subjects that glucose levels were dropping. When glucose levels were already below target (<5.0 mmol/L), mild hypoglycemia occurred five times out of 13 events (38%), despite 16 g of carbohydrate being ingested. Average glucose levels during sports in the 60 min following algorithm use were 5.8 ± 1.2 mmol/L, 5.3 ± 1.0 mmol/L, and 6.2 ± 0.8 mmol/L in the 20-, 16-, and 8-g carbohydrate intake protocols when glucose levels were initially on target but dropping toward hypoglycemia. When coupled with RT-CGM, a new carbohydrate intake algorithm prevents hypoglycemia and maintains euglycemia during exercise, particularly if patients ingest carbohydrate when trend arrows alert them of a drop in glycemia.

  12. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase 3 Wiaman Seat

    DTIC Science & Technology

    2016-07-01

    711 HPW/RHCPT) and their in-house technical support contractor , Infoscitex, conducted a series of tests to identify the performance capabilities of...Cell Seat Configuration Drop Ht . (in) Mean Peak Acceleration (G) Mean Velocity Change (ft/s) SH1 WS1 20 80.08 ± 3.71 13.54 ± 0.49 SH2...6. Test Matrix for VID Response with WS2 Test Cell Seat (Felt) Configuration Drop Ht . (in) Mean Peak Acceleration (G

  13. How (not) to interpret a non-causal association in sports injury science.

    PubMed

    Hjerrild, Mette; Videbaek, Solvej; Theisen, Daniel; Malisoux, Laurent; Oestergaard Nielsen, Rasmus

    2018-07-01

    To discuss the interpretability of non-causal associations to sports injury development exemplified via the relationship between navicular drop (ND) and running-related injury (RRI) in novice runners using neutral shoes. 1-year prospective cohort study. Denmark. 926 novice runners, representing 1852 feet, were included. The outcome was "a musculoskeletal complaint of the lower extremity or back caused by running, which restricted the amount of running for at least a week". Fewer feet with small ND than those feet with a reference ND sustained injuries at 50 (risk difference (RD) = -4.1% [95%CI = -7.9%;-0.4%]) and 100 km (RD = -5.3% [95%CI = -9.9%;-0.7%]). Similarly, fewer feet with a large ND sustained injuries than the feet with a reference drop at 250 (RD = -7.6% [95%CI = -14.9%;-0.3%]) and 500 km (RD = -9.8% [95%CI = -19.1%;-0.4%]). Non-causal associations can help to identify sub-groups of athletes at an increased or decreased risk of sports injury. Based on the current results, those with a small or large navicular drop sustain fewer injuries than those with a reference drop. Importantly, navicular drop does not cause RRIs, but influences the relationship between training load and RRI. This illustrates that non-causal associations are unsuitable to respond to the question: Why do sports injury develop? Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. A novel generation of 3D SAR-based passive micromixer: efficient mixing and low pressure drop at a low Reynolds number

    NASA Astrophysics Data System (ADS)

    Viktorov, Vladimir; Nimafar, Mohammad

    2013-05-01

    This study introduces a novel generation of 3D splitting and recombination (SAR) passive micromixer with microstructures placed on the top and bottom floors of microchannels called a ‘chain mixer’. Both experimental verification and numerical analysis of the flow structure of this type of passive micromixer have been performed to evaluate the mixing performance and pressure drop of the microchannel, respectively. We propose here two types of chain mixer—chain 1 and chain 2—and compare their mixing performance and pressure drop with other micromixers, T-, o- and tear-drop micromixers. Experimental tests carried out in the laminar flow regime with a low Reynolds number range, 0.083 ≤ Re ≤ 4.166, and image-based techniques are used to evaluate the mixing efficiency. Also, the computational fluid dynamics code, ANSYS FLUENT-13.0 has been used to analyze the flow and pressure drop in the microchannel. Experimental results show that the chain and tear-drop mixer's efficiency is very high because of the SAR process: specifically, an efficiency of up to 98% can be achieved at the tested Reynolds number. The results also show that chain mixers have a lower required pressure drop in comparison with a tear-drop micromixer.

  15. B-52B-008/DTV (Drop Test Vehicle) configuration 1 (with and without fins) flight test results - captive flight and drop test missions

    NASA Technical Reports Server (NTRS)

    Quade, D. A.

    1978-01-01

    The B-52B-008 drop test consisted of one takeoff roll to 60 KCAS, two captive flights to accomplish limited safety of flight flutter and structural demonstration testing, and seven drop test flights. Of the seven drop test missions, one flight was aborted due to the failure of the hook mechanism to release the drop test vehicle (DTV); but the other six flights successfully dropped the DTV.

  16. 40 CFR 53.22 - Generation of test atmospheres.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Generation of test atmospheres. 53.22... Characteristics of Automated Methods for SO2, CO, O3, and NO2 § 53.22 Generation of test atmospheres. (a) Table B-2 to subpart B of part 53 specifies preferred methods for generating test atmospheres and suggested...

  17. 40 CFR 53.22 - Generation of test atmospheres.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Generation of test atmospheres. 53.22... Characteristics of Automated Methods for SO2, CO, O3, and NO2 § 53.22 Generation of test atmospheres. (a) Table B-2 to subpart B of part 53 specifies preferred methods for generating test atmospheres and suggested...

  18. 40 CFR 53.22 - Generation of test atmospheres.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Generation of test atmospheres. 53.22... Characteristics of Automated Methods for SO2, CO, O3, and NO2 § 53.22 Generation of test atmospheres. (a) Table B-2 to subpart B of part 53 specifies preferred methods for generating test atmospheres and suggested...

  19. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedures. 53.23 Section 53.23... Methods SO2, CO, O3, and NO2 § 53.23 Test procedures. (a) Range—(1) Technical definition. Nominal minimum... specified at the lower and upper range limits in concentration units, for example, 0-0.5 p/m. (2) Test...

  20. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test procedures. 53.23 Section 53.23... Methods SO2, CO, O3, and NO2 § 53.23 Test procedures. (a) Range—(1) Technical definition. Nominal minimum... specified at the lower and upper range limits in concentration units, for example, 0-0.5 p/m. (2) Test...

  1. Recycle of Immobilized Endocellulases in Different Conditions for Cellulose Hydrolysis

    PubMed Central

    Carvalho, A. F. A.; Shinya, T. Y.; Mazali, G. S.; Herculano, R. D.; Oliva-Neto, P.

    2017-01-01

    The immobilization of cellulases could be an economical alternative for cost reduction of enzyme application. The derivatives obtained in the immobilization derivatives were evaluated in recycles of paper filter hydrolysis. The immobilization process showed that the enzyme recycles were influenced by the shape (drop or sheet) and type of the mixture. The enzyme was recycled 28 times for sheets E′ and 13 times for drops B′. The derivative E′ showed the highest stability in the recycle obtaining 0.05 FPU/g, RA of 10%, and FPU Yield of 1.64 times, higher than FPU spent or Net FPU Yield of 5.3 times, saving more active enzymes. The derivative B showed stability in recycles reaching 0.15 FPU/g of derivative, yield of Recovered Activity (RA) of 25%, and FPU Yield of 1.57 times, higher than FPU spent on immobilization or Net PFU Yield of 2.81 times. The latex increased stability and resistance of the drops but did not improve the FPU/gram of derivative. PMID:28465836

  2. Effect of Electromigration on the Type of Drop Failure of Sn-3.0Ag-0.5Cu Solder Joints in PBGA Packages

    NASA Astrophysics Data System (ADS)

    Huang, M. L.; Zhao, N.

    2015-10-01

    Board-level drop tests of plastic ball grid array (PBGA) packages were performed in accordance with the Joint Electron Devices Engineering Council standard to investigate the effect of electromigration (EM) on the drop reliability of Sn-3.0Ag-0.5Cu solder joints with two substrate surface finishes, organic solderability preservative (OSP) and electroless nickel electroless palladium immersion gold (ENEPIG). In the as-soldered state, drop failures occurred at the substrate sides only, with cracks propagating within the interfacial intermetallic compound (IMC) layer for OSP solder joints and along the IMC/Ni-P interface for ENEPIG solder joints. The drop lifetime of OSP solder joints was approximately twice that of ENEPIG joints. EM had an important effect on crack formation and drop lifetime of the PBGA solder joints. ENEPIG solder joints performed better in drop reliability tests after EM, that is, the drop lifetime of ENEPIG joints decreased by 43% whereas that of OSP solder joints decreased by 91%, compared with the as-soldered cases. The more serious polarity effect, i.e., excessive growth of the interfacial IMC at the anode, was responsible for the sharper decrease in drop lifetime. The different types of drop failure of PBGA solder joints before and after EM, including the position of initiation and the propagation path of cracks, are discussed on the basis of the growth behavior of interfacial IMC.

  3. Multifractal Internet Traffic Model and Active Queue Management

    DTIC Science & Technology

    2003-01-01

    dropped by the Adaptive RED , ssthresh decreases from 64KB to 4KB and the new con- gestion window cwnd is decreased from 8KB to 1KB (Tahoe). The situation...method to predict the queuing behavior of FIFO and RED queues. In order to satisfy a given delay and jitter requirement for real time connections, and to...5.2 Vulnerability of Adaptive RED to Web-mice . . . . . . . . . . . . . 103 5.3 A Parallel Virtual Queues Structure

  4. 40 CFR Table C-3 to Subpart C of... - Test Specifications for Pb in TSP and Pb in PM10 Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Pb in PM10 Methods C Table C-3 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL..., Subpt. C, Table C-3 Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM10 Methods Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM10 Methods...

  5. 40 CFR Table C-3 to Subpart C of... - Test Specifications for Pb in TSP and Pb in PM10 Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Pb in PM10 Methods C Table C-3 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL..., Subpt. C, Table C-3 Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM10 Methods Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM10 Methods...

  6. Anterior cruciate ligament injury in female and male athletes: the relationship between foot structure and injury.

    PubMed

    Jenkins, Walter L; Killian, Clyde B; Williams, D S; Loudon, Janice; Raedeke, Suzanne G

    2007-01-01

    It has been shown that anterior cruciate ligament (ACL) injuries are more prevalent in female athletes than in male athletes. Soccer and basketball are considered high-risk sports for ACL injury in female athletes. Several studies have reported a relationship between ACL injury and measures of foot structure. This study was conducted to investigate the relationship between foot structure and ACL injury rates in female and male soccer and basketball players. One hundred five soccer and basketball players (53 women and 52 men) were recruited and divided into an ACL-normal group (n=89) and an ACL-injured group (n=16). Two measures of foot structure (subtalar joint neutral position and navicular drop test values) were recorded for each subject. An independent t test and a paired t test were used to analyze differences in ACL status, foot structure, and sex. A chi2 analysis determined whether the prevalence of ACL injury was independent of sport. No statistically significant differences were found in the foot structure measures between women and men. Female soccer and basketball players had an ACL injury rate seven times that of male players. Values derived from subtalar joint neutral position measurement and the navicular drop test were not associated with ACL injury in collegiate female and male soccer and basketball players.

  7. Looking Under a Leidenfrost Drop

    NASA Astrophysics Data System (ADS)

    Burton, Justin; Sharpe, Aaron; van der Veen, Roeland; Franco, Andres; Nagel, Sidney

    2011-11-01

    The Leidenfrost effect can be observed when small water drops move around effortlessly without sticking on a hot pan. The transition to a levitated state, where the drops rest on an insulating layer of vapor, occurs at the Leidenfrost temperature. Experiment and theory have examined the lifetime and maximum size of Leidenfrost drops. However, the liquid-vapor interface beneath the drop has not been fully charcterized. We report experiments using laser-light interference to measure the geometry of the liquid-vapor interface. By imaging the interference fringes produced between the bottom surface of the liquid and the hot substrate, we can measure the curvature of the vapor pocket beneath the drop as well as the azimuthal undulations along the neck that sits closest to the surface. From these measurements, we can extrapolate the shape of the bottom of the drop, which fluctuates in time with a period of a few milliseconds for millimeter-sized water drops. Our measurements of the azimuthal neck radius agree with predictions: the difference between the drop and neck radii, (Rd -Rn) ~0.53 λ in the limit of large drops where λ is the capillary length of the fluid. For small drops we recover the result found in that Rn ~Rd2 / λ .

  8. Deformational behaviour of knee cartilage and changes in serum cartilage oligomeric matrix protein (COMP) after running and drop landing.

    PubMed

    Niehoff, A; Müller, M; Brüggemann, L; Savage, T; Zaucke, F; Eckstein, F; Müller-Lung, U; Brüggemann, G-P

    2011-08-01

    To investigate (1) the effect of running and drop landing interventions on knee cartilage deformation and serum cartilage oligomeric matrix protein (COMP) concentration and (2) if the changes in cartilage volume correlate with the changes in serum COMP level. Knee joint cartilage volume and thickness were determined using magnetic resonance imaging (MRI) as well as COMP concentration from serum samples before and after in vivo loading of 14 healthy adults (seven male and seven female). Participants performed different loading interventions of 30 min duration on three different days: (1) 100 vertical drop landings from a 73 cm high platform, (2) running at a velocity of 2.2m/s (3.96 km), and (3) resting on a chair. Blood samples were taken immediately before, immediately after and 0.5h, 1h, 2h and 3h post intervention. Pre- and post-loading coronal and axial gradient echo MR images with fat suppression were used to determine the patellar, tibial and femoral cartilage deformation. Serum COMP levels increased immediately after the running (+30.7%, pre: 7.3U/l, 95% confidence interval (CI): 5.6, 8.9, post: 9.1U/l, 95% CI: 7.2, 11.0, P=0.001) and after drop landing intervention (+32.3%, pre: 6.8U/l, 95% CI: 5.3, 8.4; post: 8.9U/l, 95% CI: 6.8, 10.9, P=0.001). Cartilage deformation was more pronounced after running compared to drop landing intervention, with being significant (volume: P=0.002 and thickness: P=0.001) only in the lateral tibia. We found a significant correlation (r(2)=0.599, P=0.001) between changes in serum COMP (%) and in cartilage volume (%) after the drop landing intervention, but not after running. In vivo exercise interventions differentially regulate serum COMP concentrations and knee cartilage deformations. The relation between changes in COMP and in cartilage volume seems to depend on both mechanical and biochemical factors. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. Deflagration-to-Detonation Transition in Heteorogeneous Solids: A Bibliography.

    DTIC Science & Technology

    1980-11-01

    and Rockets, Vol. 9. No. 6, 1972, pp. 415-419. 1.4 Francois, D., and L. Joly; " La Rupture des Metaux; Ecole d’ete de la Colle sur Loup ," Masson et Cie...Computer Program for Multifield Fluid Flows," Los Alamos Scientific Laboratory, LA -5680, 1974. 5.3, 9 Nnderssen, K. E. B.; "Pressure Drop in Ideal...5.6, 6, 9 Forest, C. A.: "Burning and Detonation," Los Alamos Scientific Laboratory, LA -7245, July 1978. 2, 3, 4 Fox, J.; "Flow Regimes in

  10. Demographic and Environmental Factors Associated With Successful Day School Treatment Program Outcomes.

    PubMed

    Rittner, Barbara; Nochajski, Thomas; Crofford, Rebekah; Chen, Ya-Ling

    2015-01-01

    In this study the authors examine the impact of admission characteristics of 105 students admitted to a day school treatment program on outcomes. Those who graduated, earned a general education diploma (GED), or were returned to a regular classroom setting were categorized as successful and those placed in a more restrictive settings (including detention), dropped out, or left the program with no known outcome were unsuccessful. The sample was largely male (n = 78, 74.3%), Caucasian (64%, n = 67), poor (53.4%), and entered in middle school or high school (73%). The majority (53.3%) had 4 or more prior educational placements before entering. They stayed in the program on average 2.5 years (SD = 2.17) with a range from 6 days through 10 years. Forty-three (41%) students were successfully discharged. Unsuccessfully discharged students dropped out (31.4%), placed in residential programs (19%), or were psychiatrically hospitalized (5.7%). At intake, 56 (53.3%) had a history of truancy, 38 (37.1%) had a PINS and 28 (26.7%) had been on probation. African Americans were approximately 73% less likely to succeed and were more likely to be from families meeting federal poverty guidelines and to live in single family households. Those who entered the program in grades K-6 or 10-12 were over 3 times more likely to succeed than students admitted in grades 7-9. Using logistic regression to assess the bivariate relationships of the demographic characteristics with successful discharge, race, admission while in grades 7-9, having both parents at home, and number of days in the program were significantly associated with success. Having externalizing behaviors, 5 or more prior placements, history of truancy, and contact with the juvenile justice system were associated with unsuccessful outcomes. Students with a history of being in the juvenile justice system were 87% less likely to succeed in the program. Implications for school social workers are discussed.

  11. 49 CFR 178.810 - Drop test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or lower are considered... with a capacity of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop... material having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  12. 49 CFR 178.810 - Drop test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or lower are considered... with a capacity of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop... material having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  13. 49 CFR 178.810 - Drop test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... solutions with a minimum specific gravity of 0.95 for testing at −18 °C (0 °F) or lower are considered... with a capacity of 0.45 cubic meters (15.9 cubic feet) or less must be subject to an additional drop... material having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  14. Wetting properties and critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite.

    PubMed

    Bukiet, Frédéric; Couderc, Guillaume; Camps, Jean; Tassery, Hervé; Cuisinier, Frederic; About, Imad; Charrier, Anne; Candoni, Nadine

    2012-11-01

    The purposes of the present study were to (1) assess the effect of the addition of benzalkonium chloride to sodium hypochlorite on its wetting properties, contact angle, and surface energy; (2) determine the critical micellar concentration of benzalkonium chloride in sodium hypochlorite; and (3) investigate the influence of addition of benzalkonium chloride on the free chlorine level, cytotoxicity, and antiseptic properties of the mixture. Solutions of benzalkonium chloride, with concentrations ranging from 0%-1%, were mixed in 2.4% sodium hypochlorite and tested as follows. The wetting properties were investigated by measuring the contact angle of the solutions on a nondehydrated dentin surface by using the static sessile drop method. The pending drop technique was subsequently used to determine the surface energy of the solutions. The critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite was calculated from the data. When 2.4% NaOCl was mixed with benzalkonium chloride at the critical micellar concentration, 3 parameters were tested: free chloride content, cytotoxicity, and antibacterial effects against Enterococcus faecalis. The contact angle (P < .001) as well as the surface energy (P < .001) significantly decreased with increasing benzalkonium chloride concentrations. The critical micellar concentration of benzalkonium chloride in sodium hypochlorite was 0.008%. At this concentration, the addition of benzalkonium chloride had no effect on the free chlorine content, cytotoxicity, or antibacterial efficiency of the mixture. The addition of benzalkonium chloride to sodium hypochlorite at the critical micellar concentration reduced the contact angle by 51.2% and the surface energy by 53.4%, without affecting the free chloride content, cytotoxicity, or antibacterial properties of the mixture. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Additional Study of Water Droplet Median Volume Diameter (MVD) Effects on Ice Shapes

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching; Anderson, David N.

    2005-01-01

    This paper reports the result of an experimental study in the NASA Glenn Icing Research Tunnel (IRT) to evaluate how well the MVD-independent effect identified previously might apply to SLD conditions in rime icing situations. Models were NACA 0012 wing sections with chords of 53.3 and 91.4 cm. Tests were conducted with a nominal airspeed of 77 m/s (150 kt) and a number of MVD's ranging from 15 to 100 m with LWC of 0.5 to 1 g/cu m. In the present study, ice shapes recorded from past studies and recent results at SLD and Appendix-C conditions are reviewed to show that droplet diameter is not important to rime ice shape for MVD of 30 microns or larger, but for less than 30 m drop sizes a rime ice shape transition from convex to wedge to spearhead type ice shape is observed.

  16. Effects of drop set resistance training on acute stress indicators and long-term muscle hypertrophy and strength.

    PubMed

    Fink, Julius; Schoenfeld, Brad J; Kikuchi, Naoki; Nakazato, Koichi

    2018-05-01

    We investigated the effects of 2 different resistance training (RT) protocols on muscle hypertrophy and strength. The first group (N.=8) performed a single drop set (DS) and the second group (N.=8) performed 3 sets of conventional RT (normal set, NS). Eight young men in each group completed 6 weeks of RT. Muscle hypertrophy was assessed via magnetic resonance imaging (MRI) and strength via 12 repetition maximum tests before and after the 6 weeks. Acute stress markers such as muscle thickness (MT), blood lactate (BL), maximal voluntary contraction (MVC), heart rate (HR) and rating of perceived exertion (RPE) have been measured before and after one bout of RT. Both groups showed significant increases in triceps muscle cross-sectional area (CSA) (10.0±3.7%, effect size (ES) =0.47 for DS and 5.1±2.1%, ES=0.25 for NS). Strength increased in both groups (16.1±12.1%, ES=0.88 for DS and 25.2±17.5%, ES=1.34 for NS). Acute pre/post measurements for one bout of RT showed significant changes in MT (18.3±5.8%, P<0.001) and MVC (-13.3±7.1, P<0.05) in the DS group only and a significant difference (P<0.01) in RPE was observed between groups (7.7±1.5 for DS and 5.3±1.4 for NS). Superior muscle gains might be achieved with a single set of DS compared to 3 sets of conventional RT, probably due to higher stress experienced in the DS protocol.

  17. Taking the Easy Way Out: How the GED Testing Program Induces Students to Drop Out. NBER Working Paper No. 14044

    ERIC Educational Resources Information Center

    Heckman, James J.; LaFontaine, Paul A.; Rodriguez, Pedro L.

    2008-01-01

    We exploit an exogenous increase in General Educational Development (GED) testing requirements to determine whether raising the difficulty of the test causes students to finish high school rather than drop out and GED certify. We find that a six point decrease in GED pass rates induces a 1.3 point decline in overall dropout rates. The effect size…

  18. Munitions Test Area and Incendiary Drop Site, Site 36-2, Data Addendum, Phase 2.

    DTIC Science & Technology

    1988-09-01

    MUNITIONS TEST AREA AND INCENDIARY DROP SITE (NI September 1988 Contract Number DAAK11-84-D-0016 | • (Version 3.1) Environmental Science And Engineering, Inc...SITE, September 1988 Contract Number DAAK11-84-D-0016 (Version 3.1)I PREPARED BY ENVIRONMENTAL SCIENCE AND ENGINEERING, INC. Harding Lawson Associates I...the Program Managers Office (PMO). Environmental Science and Engineering (ESE), Morrison-Knudsen Engineers (MKE), and Harding Lawson Associates (HLA

  19. Nondestructive spot test method for magnesium and magnesium alloys

    NASA Technical Reports Server (NTRS)

    Wilson, M. L. (Inventor)

    1973-01-01

    A method for spot test identification of magnesium and various magnesium alloys commonly used in aerospace applications is described. The spot test identification involves color codes obtained when several drops of 3 M hydrochloric acid are placed on the surface to be tested. After approximately thirty seconds, two drops of this reacted acid is transferred to each of two depressions in a spot plate for additions of other chemicals with subsequent color changes indicating magnesium or its alloy.

  20. Measurement and modelling of forced convective heat transfer coefficient and pressure drop of Al2O3- and SiO2-water nanofluids

    NASA Astrophysics Data System (ADS)

    Julia, J. E.; Hernández, L.; Martínez-Cuenca, R.; Hibiki, T.; Mondragón, R.; Segarra, C.; Jarque, J. C.

    2012-11-01

    Forced convective heat transfer coefficient and pressure drop of SiO2- and Al2O3-water nanofluids were characterized. The experimental facility was composed of thermal-hydraulic loop with a tank with an immersed heater, a centrifugal pump, a bypass with a globe valve, an electromagnetic flow-meter, a 18 kW in-line pre-heater, a test section with band heaters, a differential pressure transducer and a heat exchanger. The test section consists of a 1000 mm long aluminium pipe with an inner diameter of 31.2 mm. Eighteen band heaters were placed all along the test section in order to provide a uniform heat flux. Heat transfer coefficient was calculated measuring fluid temperature using immersed thermocouples (Pt100) placed at both ends of the test section and surface thermocouples in 10 axial locations along the test section (Pt1000). The measurements have been performed for different nanoparticles (Al2O3 and SiO2 with primary size of 11 nm and 12 nm, respectively), volume concentrations (1% v., 5% v.), and flow rates (3 103Re<105). Maximum heat transfer coefficient enhancement (300%) and pressure drop penalty (1000%) is obtained with 5% v. SiO2 nanofluid. Existing correlations can predict, at least in a first approximation, the heat transfer coefficient and pressure drop of nanofluids if thermal conductivity, viscosity and specific heat were properly modelled.

  1. THRESHOLD STUDIES ON TNT, COMPOSITION B, C-4, AND ANFO EXPLOSIVES USING THE STEVEN IMPACT TEST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandersall, K S; Switzer, L L; Garcia, F

    2006-06-20

    Steven Impact Tests were performed at low velocity on the explosives TNT (trinitrotolulene), Composition B (63% RDX, 36% TNT, and 1% wax by weight), C-4 (91% RDX, 5.3% Di (2-ethylhexyl) sebacate, 2.1% Polyisobutylene, and 1.6% motor oil by weight) and ANFO (94% ammonium Nitrate with 6% Fuel Oil) in attempts to obtain a threshold for reaction. A 76 mm helium driven gas gun was used to accelerate the Steven Test projectiles up to approximately 200 m/s in attempts to react (ignite) the explosive samples. Blast overpressure gauges, acoustic microphones, standard video and high-speed photography were used to characterize the levelmore » of any high explosive reaction violence. No bulk reactions were observed in the TNT, Composition B, C-4 or ANFO explosive samples impacted up to velocities in the range of 190-200 m/s. This work will outline the experimental details and discuss the lack of reaction when compared to the reaction thresholds of other common explosives. These results will also be compared to that of the Susan Test and reaction thresholds observed in the common small-scale safety tests such as the drop hammer and friction tests in hopes of drawing a correlation.« less

  2. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... coefficient of variation (§ 53.53) (L-7.4.3) Filter temperature control (sampling) (§ 53.57) (L-7.4.10) Elapsed sample time accuracy (§ 53.54) (L-7.4.13) Filter temperature control (post sampling) (§ 53.57) (L... requirements (part 53, subpart A, § 53.2(a)(3)) (part 53, subpart E, § 53.51(a),(d)) Filter Weighing (L-8...

  3. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... coefficient of variation (§ 53.53) (L-7.4.3) Filter temperature control (sampling) (§ 53.57) (L-7.4.10) Elapsed sample time accuracy (§ 53.54) (L-7.4.13) Filter temperature control (post sampling) (§ 53.57) (L... requirements (part 53, subpart A, § 53.2(a)(3)) (part 53, subpart E, § 53.51(a),(d)) Filter Weighing (L-8...

  4. 40 CFR 53.22 - Generation of test atmospheres.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... test concentration shall be verified. (b) The test atmosphere delivery system shall be designed and... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Generation of test atmospheres. 53.22... Characteristics of Automated Methods SO2, CO, O3, and NO2 § 53.22 Generation of test atmospheres. (a) Table B-2...

  5. 40 CFR 53.22 - Generation of test atmospheres.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... test concentration shall be verified. (b) The test atmosphere delivery system shall be designed and... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Generation of test atmospheres. 53.22... Characteristics of Automated Methods SO2, CO, O3, and NO2 § 53.22 Generation of test atmospheres. (a) Table B-2...

  6. Effects of probiotic drop containing Lactobacillus rhamnosus, Bifidobacterium infantis, and Lactobacillus reuteri on salivary Streptococcus mutans and Lactobacillus levels

    PubMed Central

    Tehrani, Maryam Hajnorouzali; Akhlaghi, Najmeh; Talebian, Leila; Emami, Jaber; Keyhani, Siamak Etzad

    2016-01-01

    Aims: The aim of the present study was to evaluate the effect of a probiotic drop containing Lactobacillus rhamnosus, Bifidobacterium infantis, and Lactobacillus reuteri on salivary counts of Streptococcus mutans (SM) and Lactobacillus (LB) in children 3–6 years of age. Settings and Design: Sixty-one healthy children were randomly allocated into two parallel blocks in this double-blind, randomized controlled trial (IRCT2014120320202N1) from May to June 2015. Subjects and Methods: Finally 53 participants consumed five drops of placebo (n = 23) or probiotic (n = 30) every night for 2 weeks. Before intervention and 1 day after completion of the intervention, unstimulated salivary samples were collected, and microbiologic evaluations were carried out. Statistical Analysis: Data were analyzed with descriptive statistical methods Wilcoxon signed ranks, Mann–Whitney, and logistic regression. Results: SM level decreased significantly in probiotic group after intervention (P = 0.045), and there were significant differences in salivary SM counts after intervention between two groups (P = 0.04). In probiotic group, LB counts decreased significantly after intervention (P = 0.048); however, there were no significant differences between two groups (P = 0.216). Conclusions: Use of this probiotic drop decreased salivary counts of SM; however, LB counts did not change. In addition, use of the drop in children with higher salivary counts appeared to be more effective. PMID:27994413

  7. Crash Simulation of a Vertical Drop Test of a B737 Fuselage Section with Overhead Bins and Luggage

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.

    2004-01-01

    The focus of this paper is to describe a crash simulation of a 30-ft/s vertical drop test of a Boeing 737 (B737) fuselage section. The drop test of the 10-ft. long fuselage section of a B737 aircraft was conducted in November of 2000 at the FAA Technical Center in Atlantic City, NJ. The fuselage section was outfitted with two different commercial overhead stowage bins. In addition, 3,229-lbs. of luggage were packed in the cargo hold to represent a maximum take-off weight condition. The main objective of the test was to evaluate the response and failure modes of the overhead stowage bins in a narrow-body transport fuselage section when subjected to a severe, but survivable, impact. A secondary objective of the test was to generate experimental data for correlation with the crash simulation. A full-scale 3-dimensional finite element model of the fuselage section was developed and a crash simulation was conducted using the explicit, nonlinear transient dynamic code, MSC.Dytran. Pre-test predictions of the fuselage and overhead bin responses were generated for correlation with the drop test data. A description of the finite element model and an assessment of the analytical/experimental correlation are presented. In addition, suggestions for modifications to the model to improve correlation are proposed.

  8. Shock-absorbing effect of shoe insert materials commonly used in management of lower extremity disorders.

    PubMed

    Shiba, N; Kitaoka, H B; Cahalan, T D; Chao, E Y

    1995-01-01

    The efficacy of 3 shock-absorbing materials was compared by determining impact characteristics with a drop test method and also by testing the effect of each material when used as a shoe insert in 16 asymptomatic subjects. Peak vertical ground reaction force (F1, F2, F3) and temporal force factors (T1, T2, T3) were obtained with a force plate at a high-frequency sampling rate. Impact force, impact time, impact slope, and impact energy were determined. A standard weight was dropped from 3 heights on each material covering the force plate while reduction of peak force was compared. Impact force was attenuated most effectively by Insert 3 (polymeric foam rubber) and averaged 11% less than that in shoes without inserts. Impact time was increased for all 3 inserts. Impact slope and impact energy were reduced significantly in Insert 3. There was a significant difference in peak vertical force F1 for all 3 inserts, in vertical force F2 for Insert 2 (viscoelastic polymeric material), and in vertical force F3 for Insert 2. Drop-test studies showed that at all ball heights, the highest mean peak force was observed consistently in Insert 2.

  9. Study of imbalanced internal resistance on drop voltage of LiFePO4 battery system connected in parallel

    NASA Astrophysics Data System (ADS)

    Adie Perdana, Fengky; Supriyanto, Agus; Purwanto, Agus; Jamaluddin, Anif

    2017-01-01

    The purpose of this research focuses on the effect of imbalanced internal resistance for the drop voltage of LiFePO4 18650 battery system connected in parallel. The battery pack has been assembled consist of two cell battery LiFePO4 18650 that has difference combination of internal resistance. Battery pack was tested with 1/C constant current charging, 3,65V per group sel, 3,65V constant voltage charging, 5 minutes of rest time between charge and discharge process, 1/2C Constant current discharge until 2,2V, 26 cycle of measurement test, and 4320 minutes rest time after the last charge cycle. We can conclude that the difference combination of internal resistance on the battery pack seriously influence the drop voltage of a battery. Theoretical and experimental result show that the imbalance of internal resistance during cycling are mainly responsible for the drop voltage of LiFePO4 parallel batteries. It is thus a good way to avoid drop voltage fade of parallel battery system by suppressing variations of internal resistance.

  10. Quadriceps Strength Deficit at 6 Months After ACL Reconstruction Does Not Predict Return to Preinjury Sports Level.

    PubMed

    Novaretti, João Victor; Franciozi, Carlos Eduardo; Forgas, Andrea; Sasaki, Pedro Henrique; Ingham, Sheila Jean McNeill; Abdalla, Rene Jorge

    There is a lack of literature-based objective criteria for return to sport after anterior cruciate ligament (ACL) injury. Establishing such objective criteria is crucial to improving return to sport after ACL reconstruction (ACLR). Patients who return to their preinjury level of sport will have higher isokinetic, postural stability, and drop vertical jump test scores 6 months after surgery and greater patient satisfaction compared with those who did not. Additionally, quadriceps strength deficit cutoff values of 80% and 90% would differentiate patients who returned to preinjury sports level from those who did not. Cohort study. Level 3. A retrospective search was conducted to identify all patients who underwent ACLR and completed isokinetic evaluation, postural stability analysis, and drop vertical jump testing at 6 months postoperatively. Patients were asked to complete 3 questionnaires at a minimum 1 year after surgery. Chi-square and logistic regression analyses were used for categorical dependent variables, while the Student t test, Pearson correlation, or analyses of variance with Bonferroni post hoc testing were used for continuous dependent variables. A post hoc power analysis was completed. Based on the results regarding correlations between return to preinjury level and all other variables, effect sizes from 0.24 to 3.03 were calculated. With these effect sizes, an alpha of 0.05 and sample size of 58, a power ranging from 0.15 to 0.94 was calculated. The rates of return to preinjury level and to any sports activity were 53.4% and 84.4%. Those who were able to return to their preinjury level of sport (n = 33) showed significantly higher Lysholm (91.6 ± 9.7 vs 76.7 ± 15.4) and International Knee Documentation Committee (IKDC) (83.6 ± 10.6 vs 69.8 ± 14.6) values compared with those who were unable to return to their preinjury level of sport (n = 25) ( P < 0.001). No significant differences were found for the clinical evaluations between those who were and those who were not able to return at the same level for the clinical evaluations (isokinetic evaluation, postural stability, drop vertical jump test) ( P > 0.05). No significant differences were found when comparing quadriceps strength deficit with cutoff values of 80% and 90% for return to preinjury activity level (Tegner), Lysholm, and IKDC scores. Quadriceps strength deficit, regardless of cutoff value (80% or 90%), at 6 months after ACLR does not predict return to preinjury level of sport. Patients who returned to sport at their preinjury level were more satisfied with their reconstruction compared with those who did not. Quadriceps strength deficit is not a reliable predictor of return to sports, and therefore it should not be used as the single criterion in such evaluations.

  11. B-52B/DTV (Drop Test Vehicle) flight test results: Drop test missions

    NASA Technical Reports Server (NTRS)

    Doty, L. J.

    1985-01-01

    The NASA test airplane, B-52B-008, was a carrier for drop tests of the shuttle booster recovery parachute system. The purpose of the test support by Boeing was to monitor the vertical loads on the pylon hooks. The hooks hold the Drop Test Vehicle to the B-52 pylon during drop test missions. The loads were monitored to assure the successful completion of the flight and the safety of the crew.

  12. Load and dynamic assessment of B-52B-008 carrier aircraft for finned configuration 1 space shuttle solid rocket booster decelerator subsystem drop test vehicle. Volume 3: Pylon load data method 1

    NASA Technical Reports Server (NTRS)

    Quade, D. A.

    1978-01-01

    The pylon loading at the drop test vehicle and wing interface attach points is presented. The loads shown are determined using a stiffness method, which assumes the side stiffness of the foreward hook guide to be one-fourth of the fore and aft stiffness of each drag pin. The net effect of this assumption is that the forward hook guide reacts approximately 85% of the drop test vehicle yawing moment. For a comparison of these loads to previous X-15 analysis design loadings, see Volume 1 of this document.

  13. Using asymmetry analysis to reduce normal variability of Spectral Domain Optical Coherence Tomography (SD-OCT) macular thickness

    NASA Astrophysics Data System (ADS)

    Alluwimi, Muhammed Saad

    Purpose: To investigate the use of asymmetry analysis to reduce normal between-subject variability of macular thickness measurements using SD-OCT. Methods: 63 volunteers free of eye disease were recruited: 33 young subjects (ages 21 to 35 years with mean and SD of 25 +/- 1.7), and 30 older subjects (ages 45 to 85 years with mean and SD of 66.7 +/- 9.0). All participants passed a comprehensive ophthalmic examination within the past two years. Macular images were gathered with the Spectralis OCT (V 5.4, Heidelberg Engineering, GmbH). The overlay 8x8 grid was manually centered on the fovea and aligned with the foveal-disc axis, then divided into five zones per hemifield following the method of Um et al (2012 IOVS 53:1139); asymmetry was computed as the difference between superior and inferior zone thicknesses. We assumed that the lowest variation and the highest density of ganglion cells will be found ~3° to 6° from the foveal center, corresponding to zones 1 and 2. For each zone and age group, between-subject standard deviations (SDs) were compared for retinal thickness (RT) versus asymmetry using an F-test. To account for repeated measures, a probability of p < 0.0125 was required for statistical significance. Axial length (AL) and corneal curvature (CC) were measured with an IOLMaster by the same operator and during the same imaging session. Results: For OD, asymmetry analysis reduced between-subject variability in zones 1 and 2 in both groups (F > 3.2, p < 0.001). SD for zone 1 dropped from 12.0 to 3.0 mum in the young group and from 11.7 to 2.6 mum in the older group. SD for zone 2 dropped from 13.6 to 5.3 mum (young) and from 11.1 to 5.8 mum (older). Combining all subjects, neither RT nor asymmetry showed a strong correlation with AL or CC (R2 < 0.01). Analysis for OS yielded the same pattern of results, as did asymmetry analyses between eyes (F > 3.8, p < 0.0001). Conclusions: Asymmetry analysis reduced between-subject variability. These findings demonstrate the potential usefulness of the RT asymmetry analysis for improving ability to detect glaucomatous damage to the macula.

  14. Prospective, randomized, controlled comparison of SYSTANE UD eye drops versus VISINE INTENSIV 1% EDO eye drops for the treatment of moderate dry eye.

    PubMed

    Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus

    2012-12-01

    The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.

  15. The effect of roof strength on reducing occupant injury in rollovers.

    PubMed

    Herbst, Brian; Forrest, Steve; Orton, Tia; Meyer, Steven E; Sances, Anthony; Kumaresan, Srirangam

    2005-01-01

    Roof crush occurs and potentially contributes to serious or fatal occupant injury in 26% of rollovers. It is likely that glazing retention is related to the degree of roof crush experienced in rollover accidents. Occupant ejection (including partial ejection) is the leading cause of death and injury in rollover accidents. In fatal passenger car accidents involving ejection, 34% were ejected through the side windows. Side window glass retention during a rollover is likely to significantly reduce occupant ejections. The inverted drop test methodology is a test procedure to evaluate the structural integrity of roofs under loadings similar to those seen in real world rollovers. Recent testing on many different vehicle types indicates that damage consistent with field rollover accidents can be achieved through inverted drop testing at very small drop heights. Drop test comparisons were performed on 16 pairs of vehicles representing a large spectrum of vehicle types. Each vehicle pair includes a production vehicle and a vehicle with a reinforced roof structure dropped under the same test conditions. This paper offers several examples of post-production reinforcements to roof structures that significantly increase the crush resistance of the roof as measured by inverted drop tests. These modifications were implemented with minimal impact on vehicle styling, interior space and visual clearances. The results of these modifications indicate that roof crush can be mitigated by nearly an order of magnitude, as roof crush was reduced by 44-91% with only a 1-2.3% increase in vehicle weight. Additionally, this paper analyzes the glazing breakage patterns in the moveable tempered side windows on the side adjacent to the vehicle impact point in the inverted drop tests. A comparison is made between the production vehicles and the reinforced vehicles in order to determine if the amount roof crush is related to glazing integrity in the side windows. Lastly, two drop test pairs, performed with Hybrid III test dummies, indicates that the reduction of roof crush resulted in a direct reduction in neck loading and therefore an increase in occupant protection.

  16. Experimental study of effectiveness of four radon mitigation solutions, based on underground depressurization, tested in prototype housing built in a high radon area in Spain.

    PubMed

    Frutos Vázquez, Borja; Olaya Adán, Manuel; Quindós Poncela, Luis Santiago; Sainz Fernandez, Carlos; Fuente Merino, Ismael

    2011-04-01

    The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. 384 hanging drop arrays give excellent Z-factors and allow versatile formation of co-culture spheroids.

    PubMed

    Hsiao, Amy Y; Tung, Yi-Chung; Qu, Xianggui; Patel, Lalit R; Pienta, Kenneth J; Takayama, Shuichi

    2012-05-01

    We previously reported the development of a simple, user-friendly, and versatile 384 hanging drop array plate for 3D spheroid culture and the importance of utilizing 3D cellular models in anti-cancer drug sensitivity testing. The 384 hanging drop array plate allows for high-throughput capabilities and offers significant improvements over existing 3D spheroid culture methods. To allow for practical 3D cell-based high-throughput screening and enable broader use of the plate, we characterize the robustness of the 384 hanging drop array plate in terms of assay performance and demonstrate the versatility of the plate. We find that the 384 hanging drop array plate performance is robust in fluorescence- and colorimetric-based assays through Z-factor calculations. Finally, we demonstrate different plate capabilities and applications, including: spheroid transfer and retrieval for Janus spheroid formation, sequential addition of cells for concentric layer patterning of different cell types, and culture of a wide variety of cell types. Copyright © 2011 Wiley Periodicals, Inc.

  18. 384 Hanging Drop Arrays Give Excellent Z-factors and Allow Versatile Formation of Co-culture Spheroids

    PubMed Central

    Hsiao, Amy Y.; Tung, Yi-Chung; Qu, Xianggui; Patel, Lalit R.; Pienta, Kenneth J.; Takayama, Shuichi

    2012-01-01

    We previously reported the development of a simple, user-friendly, and versatile 384 hanging drop array plate for 3D spheroid culture and the importance of utilizing 3D cellular models in anti-cancer drug sensitivity testing. The 384 hanging drop array plate allows for high-throughput capabilities and offers significant improvements over existing 3D spheroid culture methods. To allow for practical 3D cell-based high-throughput screening and enable broader use of the plate, we characterize the robustness of the 384 hanging drop array plate in terms of assay performance and demonstrate the versatility of the plate. We find that the 384 hanging drop array plate performance is robust in fluorescence- and colorimetric-based assays through z-factor calculations. Finally, we demonstrate different plate capabilities and applications, including: spheroid transfer and retrieval for Janus spheroid formation, sequential addition of cells for concentric layer patterning of different cell types, and culture of a wide variety of cell types. PMID:22161651

  19. Predicting the Drop Performance of Solder Joints by Evaluating the Elastic Strain Energy from High-Speed Ball Pull Tests

    NASA Astrophysics Data System (ADS)

    You, Taehoon; Kim, Yunsung; Kim, Jina; Lee, Jaehong; Jung, Byungwook; Moon, Jungtak; Choe, Heeman

    2009-03-01

    Despite being expensive and time consuming, board-level drop testing has been widely used to assess the drop or impact resistance of the solder joints in handheld microelectronic devices, such as cellphones and personal digital assistants (PDAs). In this study, a new test method, which is much simpler and quicker, is proposed. The method involves evaluating the elastic strain energy and relating it to the impact resistance of the solder joint by considering the Young’s modulus of the bulk solder and the fracture stress of the solder joint during a ball pull test at high strain rates. The results show that solder joints can be ranked in order of descending elastic strain energy as follows: Sn-37Pb, Sn-1Ag-0.5Cu, Sn-3Ag-0.5Cu, and Sn-4Ag-0.5Cu. This order is consistent with the actual drop performances of the samples.

  20. Development of a test facility and preliminary testing of flow boiling heat transfer of R410A refrigerant with Al2O3 nanolubricants

    NASA Astrophysics Data System (ADS)

    Wong, Thiam

    In vapor compression cycles, a small portion of the oil circulates with the refrigerant throughout the system components, while most of the oil stays in the compressors. In heat exchangers, the lubricant in excess penalizes the heat transfer and increases the pressure losses: both effects are highly undesired but yet unavoidable. Nanoparticles dispersed in the excess lubricant are expected to provide enhancements in heat transfer. While solubility and miscibility of refrigerants in polyolesters (POE) lubricant are well established knowledge, there is a lack of information regarding if and how nanoparticles dispersed in the lubricant affect these properties. This thesis presents experimental data of solubility of two types of Al2O3 nanolubricants with refrigerant R-410A. The nanoparticles were dispersed in POE lubricant by using different surfactants and dispersion methods. The nanolubricants appeared to have slightly lower solubility than that of R-410A but actually the solid nanoparticles did not really interfere with the POE oil solubility characteristics. A test facility and experimental methodology was developed for the investigation of heat transfer coefficient and pressure drop. The pressure drop of the refrigerant lubricant mixtures during flow boiling depended on the mass flux of the refrigerant. Greater augmentation was seen in the pressure drop results with decreasing mass flow rate. Pure refrigerant R410A showed the lowest pressure drop, addition of nanolubricants to the refrigerant showed a slightly higher pressure drop and POE-refrigerant mixture showed the highest pressure drop in the tests conducted. Enhancement or degradation in heat transfer coefficient during flow boiling depended on the nanoparticle concentration in the lubricant as well as the lubricant concentration in refrigerant. R410A showed the highest heat transfer coefficient for all conditions tested. For a concentration of 1% nanolubricant in refrigerant, the heat transfer coefficient showed more enhancement with increase in nanoparticle concentration compared to POE refrigerant mixtures. For a concentration of 3% nanolubricant in refrigerant mixtures there was little to no enhancement for tests conducted.

  1. Design of a Helmet Liner for Improved Low Velocity Impact Protection

    DTIC Science & Technology

    2013-05-01

    FIGURE 14. MONORAIL DROP TEST WITH DOT-SIZE C HEADFORM AND HEMISPHERICAL ANVIL ........................... 14  FIGURE 15. ACH PAD CONFIGURATION. LEFT...materials. In this project, the monorail drop test device, used for the helmeted headform drop test, was modified for material testing as shown in Figure...a guided free fall drop test using a monorail drop test apparatus as shown in Figure 14. All helmets tested in this study were ACH-Size Large and

  2. The effect of temperature, matrix alloying and substrate coatings on wettability and shear strength of Al/Al2O3 couples

    NASA Astrophysics Data System (ADS)

    Sobczak, N.; Ksiazek, M.; Radziwill, W.; Asthana, R.; Mikulowski, B.

    2004-03-01

    A fresh approach has been advanced to examine in the Al/Al2O3 system the effects of temperature, alloying of Al with Ti or Sn, and Ti and Sn coatings on the substrate, on contact angles measured using a sessile-drop test, and on interface strength measured using a modified push-off test that allows shearing of solidified droplets with less than 90 deg contact angle. In the modified test, the solidified sessile-drop samples are bisected perpendicular to the drop/Al2O3 interface at the midplane of the contact circle to obtain samples that permit bond strength measurement by stress application to the flat surface of the bisected couple. The test results show that interface strength is strongly influenced by the wetting properties; low contact angles correspond to high interface strength, which also exhibits a strong temperature dependence. An increase in the wettability test temperature led to an increase in the interface strength in the low-temperature range where contact angles were large and wettability was poor. The room-temperature shear tests conducted on thermally cycled sessile-drop test specimens revealed the effect of chemically formed interfacial oxides; a weakening of the thermally cycled Al/Al2O3 interface was caused under the following conditions: (1) slow contact heating and short contact times in the wettability test, and (2) fast contact heating and longer contact times. The addition of 6 wt pct Ti or 7 wt pct Sn to Al only marginally influenced the contact angle and interfacial shear strength. However, Al2O3 substrates having thin (<1 µm) Ti coatings yielded relatively low contact angles and high bond strength, which appears to be related to the dissolution of the coating in Al and formation of a favorable interface structure.

  3. 49 CFR 173.184 - Highway or rail fusee.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (3A2), wooden (4C1, 4C2), plywood (4D) or reconstituted wood (4F) boxes or in fiberboard boxes (4G... drop test requirements (§ 178.603 of this subchapter), including at least one drop with spike in a...

  4. 49 CFR 173.184 - Highway or rail fusee.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (3A2), wooden (4C1, 4C2), plywood (4D) or reconstituted wood (4F) boxes or in fiberboard boxes (4G... drop test requirements (§ 178.603 of this subchapter), including at least one drop with spike in a...

  5. 49 CFR 173.184 - Highway or rail fusee.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (3A2), wooden (4C1, 4C2), plywood (4D) or reconstituted wood (4F) boxes or in fiberboard boxes (4G... drop test requirements (§ 178.603 of this subchapter), including at least one drop with spike in a...

  6. If you provide the test, they will take it: factors associated with HIV/STI Testing in a representative sample of homeless youth in Los Angeles.

    PubMed

    Ober, Allison J; Martino, Steven C; Ewing, Brett; Tucker, Joan S

    2012-08-01

    Homeless youth are at high risk for human immunodeficiency virus (HIV) and other sexually transmitted infections (STI), yet those at greatest risk may never have been tested for HIV or STI. In a probability sample of sexually active homeless youth in Los Angeles (n = 305), this study identifies factors associated with HIV/STI testing status. Most youth (85%) had ever been tested and 47% had been tested in the past 3 months. Recent testing was significantly more likely among youth who self-identified as gay, were Hispanic, injected drugs, and used drop-in centers, and marginally more likely among youth with more depressive symptoms. Drop-in center use mediated the association of injection drug use with HIV/STI testing. HIV/STI testing was unrelated to sexual risk behavior. Drop-in centers can play an important role in facilitating testing, including among injection drug users, but more outreach is needed to encourage testing in other at-risk subgroups.

  7. If You Provide the Test, They will Take It: Factors Associated with HIV/STI Testing in a Representative Sample of Homeless Youth in Los Angeles*

    PubMed Central

    Ober, Allison J.; Martino, Steven C.; Ewing, Brett; Tucker, Joan S.

    2012-01-01

    Homeless youth are at high risk for human immunodeficiency virus (HIV) and other sexually transmitted infections (STI), yet those at greatest risk may never have been tested for HIV or STI. In a probability sample of sexually active homeless youth in Los Angeles (n =305), this study identifies factors associated with HIV/STI testing status. Most youth (85%) had ever been tested and 47% had tested in the past 3 months. Recent testing was significantly more likely among youth who self-identified as gay, were Hispanic, injected drugs, and used drop-in centers, and marginally more likely among youth with more depressive symptoms. Drop-in center use mediated the association of injection drug use with HIV/STI testing. HIV/STI testing was unrelated to sexual risk behavior. Drop-in centers can play an important role in facilitating testing, including among injection drug users, but more outreach is needed to encourage testing in other at-risk subgroups. PMID:22827904

  8. 14 CFR 23.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Reserve energy absorption drop test. 23.727... Construction Landing Gear § 23.727 Reserve energy absorption drop test. (a) If compliance with the reserve energy absorption requirement in § 23.723(b) is shown by free drop tests, the drop height may not be less...

  9. 14 CFR 23.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Reserve energy absorption drop test. 23.727... Construction Landing Gear § 23.727 Reserve energy absorption drop test. (a) If compliance with the reserve energy absorption requirement in § 23.723(b) is shown by free drop tests, the drop height may not be less...

  10. 14 CFR 23.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Reserve energy absorption drop test. 23.727... Construction Landing Gear § 23.727 Reserve energy absorption drop test. (a) If compliance with the reserve energy absorption requirement in § 23.723(b) is shown by free drop tests, the drop height may not be less...

  11. 14 CFR 23.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Reserve energy absorption drop test. 23.727... Construction Landing Gear § 23.727 Reserve energy absorption drop test. (a) If compliance with the reserve energy absorption requirement in § 23.723(b) is shown by free drop tests, the drop height may not be less...

  12. 14 CFR 23.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Reserve energy absorption drop test. 23.727... Construction Landing Gear § 23.727 Reserve energy absorption drop test. (a) If compliance with the reserve energy absorption requirement in § 23.723(b) is shown by free drop tests, the drop height may not be less...

  13. The Eye Drop Preservative Benzalkonium Chloride Potently Induces Mitochondrial Dysfunction and Preferentially Affects LHON Mutant Cells.

    PubMed

    Datta, Sandipan; Baudouin, Christophe; Brignole-Baudouin, Francoise; Denoyer, Alexandre; Cortopassi, Gino A

    2017-04-01

    Benzalkonium chloride (BAK) is the most commonly used eye drop preservative. Benzalkonium chloride has been associated with toxic effects such as "dry eye" and trabecular meshwork degeneration, but the underlying biochemical mechanism of ocular toxicity by BAK is unclear. In this study, we propose a mechanistic basis for BAK's adverse effects. Mitochondrial O2 consumption rates of human corneal epithelial primary cells (HCEP), osteosarcoma cybrid cells carrying healthy (control) or Leber hereditary optic neuropathy (LHON) mutant mtDNA [11778(G>A)], were measured before and after acute treatment with BAK. Mitochondrial adenosine triphosphate (ATP) synthesis and cell viability were also measured in the BAK-treated control: LHON mutant and human-derived trabecular meshwork cells (HTM3). Benzalkonium chloride inhibited mitochondrial ATP (IC50, 5.3 μM) and O2 consumption (IC50, 10.9 μM) in a concentration-dependent manner, by directly targeting mitochondrial complex I. At its pharmaceutical concentrations (107-667 μM), BAK inhibited mitochondrial function >90%. In addition, BAK elicited concentration-dependent cytotoxicity to cybrid cells (IC50, 22.8 μM) and induced apoptosis in HTM3 cells at similar concentrations. Furthermore, we show that BAK directly inhibits mitochondrial O2 consumption in HCEP cells (IC50, 3.8 μM) at 50-fold lower concentrations than used in eye drops, and that cells bearing mitochondrial blindness (LHON) mutations are further sensitized to BAK's mitotoxic effect. Benzalkonium chloride inhibits mitochondria of human corneal epithelial cells and cells bearing LHON mutations at pharmacologically relevant concentrations, and we suggest this is the basis of BAK's ocular toxicity. Prescribing BAK-containing eye drops should be avoided in patients with mitochondrial deficiency, including LHON patients, LHON carriers, and possibly primary open-angle glaucoma patients.

  14. The Eye Drop Preservative Benzalkonium Chloride Potently Induces Mitochondrial Dysfunction and Preferentially Affects LHON Mutant Cells

    PubMed Central

    Datta, Sandipan; Baudouin, Christophe; Brignole-Baudouin, Francoise; Denoyer, Alexandre; Cortopassi, Gino A.

    2017-01-01

    Purpose Benzalkonium chloride (BAK) is the most commonly used eye drop preservative. Benzalkonium chloride has been associated with toxic effects such as “dry eye” and trabecular meshwork degeneration, but the underlying biochemical mechanism of ocular toxicity by BAK is unclear. In this study, we propose a mechanistic basis for BAK's adverse effects. Method Mitochondrial O2 consumption rates of human corneal epithelial primary cells (HCEP), osteosarcoma cybrid cells carrying healthy (control) or Leber hereditary optic neuropathy (LHON) mutant mtDNA [11778(G>A)], were measured before and after acute treatment with BAK. Mitochondrial adenosine triphosphate (ATP) synthesis and cell viability were also measured in the BAK-treated control: LHON mutant and human-derived trabecular meshwork cells (HTM3). Results Benzalkonium chloride inhibited mitochondrial ATP (IC50, 5.3 μM) and O2 consumption (IC50, 10.9 μM) in a concentration-dependent manner, by directly targeting mitochondrial complex I. At its pharmaceutical concentrations (107–667 μM), BAK inhibited mitochondrial function >90%. In addition, BAK elicited concentration-dependent cytotoxicity to cybrid cells (IC50, 22.8 μM) and induced apoptosis in HTM3 cells at similar concentrations. Furthermore, we show that BAK directly inhibits mitochondrial O2 consumption in HCEP cells (IC50, 3.8 μM) at 50-fold lower concentrations than used in eye drops, and that cells bearing mitochondrial blindness (LHON) mutations are further sensitized to BAK's mitotoxic effect. Conclusions Benzalkonium chloride inhibits mitochondria of human corneal epithelial cells and cells bearing LHON mutations at pharmacologically relevant concentrations, and we suggest this is the basis of BAK's ocular toxicity. Prescribing BAK-containing eye drops should be avoided in patients with mitochondrial deficiency, including LHON patients, LHON carriers, and possibly primary open-angle glaucoma patients. PMID:28444329

  15. Rectangular Drop Vehicle in the Zero Gravity Research Facility

    NASA Image and Video Library

    1969-03-21

    A rectangular drop test vehicle perched above 450-foot shaft at the Zero Gravity Research Facility at NASA Lewis Research Center. The drop tower was designed to provide five seconds of microgravity during a normal drop, but had a pneumatic gun that could quickly propel the vehicle to the top of the shaft prior to its drop, thus providing ten seconds of microgravity. The shaft contained a steel-lined vacuum chamber 20 feet in diameter and 469 feet deep. The package was stopped at the bottom of the pit by a 15-foot deep deceleration cart filled with polystyrene pellets. During normal operations, a cylindrical 3-foot diameter and 11-foot long vehicle was used to house the experiments, instrumentation, and high speed cameras. The 4.5-foot long and 1.5-foot wide rectangular vehicle, seen in this photograph, was used less frequently. A 3-foot diameter orb was used for the ten second drops. After the test vehicle was prepared it was suspended above the shaft from the top of the chamber. A lid was used to seal the top of the chamber. The vacuum system reduced the pressure levels inside the chamber. The bolt holding the vehicle was then sheared and the vehicle plummeted into the deceleration cart.

  16. Pattern of Expression of p53, Its Family Members, and Regulators during Early Ocular Development and in the Post-Mitotic Retina

    PubMed Central

    Vuong, Linda; Brobst, Daniel E.; Saadi, Anisse; Ivanovic, Ivana; Al-Ubaidi, Muayyad R.

    2012-01-01

    Purpose. Because of its role in cell cycle regulation and apoptosis, p53 may be involved in maintaining the post-mitotic state of the adult eye. To shed light on the role of p53 in retinal development and maintenance, this study investigated the pattern of expression of p53, its family members, and its regulators during the development of the mouse eye. Methods. Relative quantitative real-time PCR (qRT-PCR) was used to determine the steady-state levels of target transcripts in RNA extracted from wild-type mouse whole eyes or retinas between embryonic day (E) 15 and post-natal day (P) 30. Immunoblotting was used to compare the steady-state levels of the protein to that of the transcript. Results. Transcript and protein levels for p53 in the eye were highest at E17 and E18, respectively. However, both p53 transcript and protein levels dropped precipitously thereafter, and no protein was detected on immunoblots after P3. Expression patterns of p63, p73, Mdm2, Mdm4, and Yy1 did not follow that of p53. Immunohistochemistry analysis of the developing eye showed that both p53 and Mdm2 are abundantly expressed at E18 in all layers of the retinal neuroblast. Conclusions. Downregulation of p53 in the post-mitotic retina suggests that, although p53 may be involved in ocular and retinal development, it may play a minimal role in healthy adult retinal function. PMID:22714890

  17. On the effectiveness of incorporating shear thickening fluid with fumed silica particles in hip protectors

    NASA Astrophysics Data System (ADS)

    Haris, A.; Goh, B. W. Y.; Tay, T. E.; Lee, H. P.; Rammohan, A. V.; Tan, V. B. C.

    2018-01-01

    The objective of this research is to develop a smart hip protector by incorporating shear thickening fluid (STF) into conventional foam hip protectors. The shear thickening properties of fumed silica particles dispersed in liquid polyethylene glycol (PEG) were determined from rheological tests. Dynamic drop tests, using a 4 kg drop platen at 0.5 m drop height, were conducted to study how STF improves energy absorption as compared to unfilled foam and PEG filled foam. The results show that PEG filled foam reduces the mean peak force transmitted by a further 55% and mean peak displacement by 32.5% as compared to the unfilled foam; the STF filled foam further reduces mean peak force and displacement by 15% and 41% respectively when compared to the PEG filled foam. At a displacement of 22 mm, the STF filled foam absorbs 7.4 times more energy than the PEG filled foam. The results of varying the drop mass and drop height show that the energy absorbed per unit displacement for STF filled foam is always higher than that of PEG filled foam. Finally, the effectiveness of a prototype of hip protector made from 15 mm thick STF filled foam in preventing hip fractures was studied under two different loading conditions: distributed load (plate drop test) and concentrated load (ball drop test). The results of the plate and ball drop tests show that among all hip protectors tested in this study, only the prototype can reduce the mean peak impact force to be lower than the force required to fracture a hip bone (3.1 kN) regardless of the type of loading. Moreover, the peak force of the prototype is about half of this value, suggesting thinner prototype could have been used instead. These findings show that STF is effective in improving the performance of hip protectors.

  18. Ankle brachial index is equally predictive of exercise-induced limb ischemia in diabetic and non-diabetic patients with walking limitation.

    PubMed

    Henni, Samir; Ammi, Myriam; Gourdier, Anne-Sophie; Besnier, Louis; Signolet, Isabelle; Colas-Ribas, Christophe; Picquet, Jean; Abraham, Pierre

    2018-03-29

    In diabetic patients, arterial stiffness may impair compressibility of vessels and result in higher ankle to brachial index (ABI) than in non-diabetic subjects. We studied 1972 non-diabetic and 601 diabetic patients, with suspected peripheral artery disease, Exercise transcutaneous oxygen pressure (Ex-tcpO2), expressed in DROP index (limb tcpO2 change minus chest tcpO2 change), is insensitive to arterial stiffness and can estimate exercise-induced regional blood flow impairment (RBFI). A minimal DROP <-15 mm Hg indicates the presence of RBFI (positive test). ABI was simplified to a category variable (ABIc) by rounding ABI to the closest first decimal. In the ABIc range 0.4 to 1.1 linear regression for mean DROP values were: y = 34 x - 53; (R 2  = 0.211) and y = 33 x - 52; (R 2  = 0.186) in diabetic and Non-diabetic patients, respectively. Both Db and non-D patients showed a high proportion of positive Ex-tcpO2 tests for ABIc in the normal range (ABIc: 1.0 and over) from 27.1 to up to 58%. More than half of patients with borderline ABI (ABIc = 0.9) had RBFI during exercise. it was 65.6% in diabetic and 58.5% non-diabetic patients. Resting ABI was not a better predictor of exercise-induced RBFI in non-Db than in Diabetic patients. Our results highlights the interest of still measuring resting-ABI in diabetic patients to argue for the vascular origin of exertional limb pain, but also of performing exercise tests in patients with walking impairment. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. 40 CFR Table B-3 to Subpart B of... - Interferent Test Concentration,1 Parts per Million

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Interferent Test Concentration,1 Parts per Million B Table B-3 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION..., Subpt. B, Table B-3 Table B-3 to Subpart B of Part 53—Interferent Test Concentration,1 Parts per Million...

  20. Instantaneous stroke volume by PDE during and after constant LBNP (-50 torr)

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Six male subjects were exposed to -50 torr lower body negative pressure (LBNP) for 10 min while stroke volume was recorded beat by beat at regular intervals before, during and after release of LBNP. Stroke volume was calculated from the systolic velocity integral in the ascending aorta by pulsed Doppler echocardiography (PDE) and the cross sectional area of the vessel by M mode echocardiography. Changes in leg volume were recorded continuously and blood pressure was taken every minute. Stroke volume dropped by 51% of the control in the first 33 sec of LBNP and continued to decline slowly to -62% toward the end. Heart rate increased by 15% in the first 10 sec and was 22% above control at the end of exposure. The resulting cardiac output closely followed the course of stroke volume (-47% at 33 sec, -53% at 8 min) showing that the modest increase in heart rate did little to offset the drop in stroke volume. Leg volume increased markedly within the first 10 sec with a more gradual rise reaching +3.5% at the end. Upon sudden release of LBNP, leg volume dropped significantly during the first 3 sec simultaneously with an increase in stroke volume followed by a substantial decline in heart rate below the baseline.

  1. Bounce—the answer

    NASA Astrophysics Data System (ADS)

    Featonby, David

    2018-05-01

    In my article (Featonby 2018 Phys. Educ. 53 027002) Three experiments were presented which involved dropping objects and observing the “bounce”. The question was, for each object, can you predict what might happen and explain the differences.

  2. Potatoes and elastic—the answer

    NASA Astrophysics Data System (ADS)

    Featonby, D.

    2018-07-01

    In my article (Featonby 2018 Phys. Educ. 53 037002) we asked what happens when two objects connected by elastic are held vertically, so that the elastic is stretched, and dropped. Which object reaches the ground first.

  3. 40 CFR Table B-4 to Subpart B of... - Line Voltage and Room Temperature Test Conditions

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Conditions B Table B-4 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Testing Performance Characteristics of Automated Methods for SO2, CO, O3, and NO2 Pt. 53, Subpt. B, Table B-4 Table B-4 to Subpart B of Part 53—Line Voltage and Room Temperature Test Conditions Test day...

  4. 40 CFR Table B-4 to Subpart B of... - Line Voltage and Room Temperature Test Conditions

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Conditions B Table B-4 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Testing Performance Characteristics of Automated Methods for SO2, CO, O3, and NO2 Pt. 53, Subpt. B, Table B-4 Table B-4 to Subpart B of Part 53—Line Voltage and Room Temperature Test Conditions Test day...

  5. 40 CFR Table B-4 to Subpart B of... - Line Voltage and Room Temperature Test Conditions

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Conditions B Table B-4 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Testing Performance Characteristics of Automated Methods for SO2, CO, O3, and NO2 Pt. 53, Subpt. B, Table B-4 Table B-4 to Subpart B of Part 53—Line Voltage and Room Temperature Test Conditions Test day...

  6. Side preference in adults for holding infants: contributions of sex and handedness in a test of imagination.

    PubMed

    Harris, L J; Almerigi, J B; Kirsch, E A

    2000-01-01

    Five hundred one right-handers (150 men, 351 women) and 53 left-handers (15 men, 38 women) were asked to imagine holding a young infant in their arms. Right-handers reported significant left-side biases--in 68% of the men and 73% of the women. For left-handers, side preferences were weaker, the left-side bias dropping to 47% for men and 60% for women, with neither figure different from chance. The results are discussed in the context of theory and research on the functional neuroanatomy of attention, emotional arousal, and the generation, maintenance, and manipulation of mental images.

  7. The Effect of Arch Drop on Tibial Rotation and Tibiofemoral Contact Stress in Postpartum Women.

    PubMed

    Rabe, Kaitlin; Segal, Neil A; Waheed, Saphia; Anderson, Donald D

    2018-04-26

    Women are at greater risk for knee osteoarthritis and numerous other lower limb musculoskeletal disorders. Arch drop during pregnancy and the resultant excessive pronation of the feet may alter loading patterns and contribute to the greater prevalence of knee osteoarthritis in women. To determine the effect of arch drop on tibial rotation and tibiofemoral contact stress. Interventional study with internal control. Biomechanics laboratory. Eleven postpartum women (age 33.4 ± 5.3 years, body mass 76.1 ± 13.5 kg) who had lost arch height with pregnancy in a previous study. Subjects underwent standing computed tomography (SCT) with their knees in a 20° fixed-flexed position with and without semirigid arch supports to reconstitute prepregnancy arch height. Magnetic resonance imaging of the knee was acquired at a flexion angle equivalent to that of SCT. Bone and cartilage were manually segmented on the magnetic resonance images and segmented surfaces were registered to the 3-dimensional SCT image sets for the arch-supported and -unsupported conditions. These models were used to measure changes in tibial rotation, as well as to estimate contact stress in the medial and lateral tibiofemoral compartments, using computational methods. Change in tibial rotation and tibiofemoral contact stress with arch drop. Arch drop resulted in a mean tibial internal rotation of 0.75 ± 1.33° (P < .05). Changes in mean or peak contact stress were not detected. Arch drop causes internal tibial rotation, resulting in a shift in the tibiofemoral articulation. An associated increase in contact stress was not detected. Internal rotation of the tibia increases stress on the anterior cruciate ligament and menisci, potentially explaining the greater prevalence of knee disorders in postpartum women. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  9. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  10. 14 CFR 29.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Reserve energy absorption drop test. 29.727 Section 29.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION....727 Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as...

  11. 14 CFR 27.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Reserve energy absorption drop test. 27.727 Section 27.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as follows...

  12. 14 CFR 27.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Reserve energy absorption drop test. 27.727 Section 27.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as follows...

  13. 14 CFR 27.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Reserve energy absorption drop test. 27.727 Section 27.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as follows...

  14. 14 CFR 29.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Reserve energy absorption drop test. 29.727 Section 29.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION....727 Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as...

  15. 14 CFR 27.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Reserve energy absorption drop test. 27.727 Section 27.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as follows...

  16. 14 CFR 27.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Reserve energy absorption drop test. 27.727 Section 27.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as follows...

  17. 14 CFR 29.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Reserve energy absorption drop test. 29.727 Section 29.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION....727 Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as...

  18. 14 CFR 29.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Reserve energy absorption drop test. 29.727 Section 29.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION....727 Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as...

  19. 14 CFR 29.727 - Reserve energy absorption drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Reserve energy absorption drop test. 29.727 Section 29.727 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION....727 Reserve energy absorption drop test. The reserve energy absorption drop test must be conducted as...

  20. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Drop test. 572.102 Section 572.102 Transportation..., DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Free Motion Headform § 572.102 Drop test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  1. Camphor-Crataegus berry extract combination dose-dependently reduces tilt induced fall in blood pressure in orthostatic hypotension.

    PubMed

    Belz, G G; Butzer, R; Gaus, W; Loew, D

    2002-10-01

    In order to test the efficacy of a combination of natural D-camphor and an extract of fresh crataegus berries (Korodin Herz-Kreislauf-Tropfen) on orthostatic hypotension, two similar, controlled, randomized studies were carried out in a balanced crossover design in 24 patients each with orthostatic dysregulation. The camphor-crataegus berry combination (CCC) was orally administered as a single regimen in 3 different dosages of 5 drops, 20 drops and 80 drops; a placebo with 20 drops of a 60% alcoholic solution served as control. Orthostatic hypotension was assessed with the tilt table test before and after medication. Source data of both studies were pooled and meta-analytically evaluated for all 48 patients. CCC drops decreased the orthostatic fall in blood pressure versus placebo, as almost uniformly established at all times by mean arterial pressure and diastolic blood pressure. Mean arterial pressure demonstrated the very fast onset of action by a clearly dose-dependent statistically significant effect even after 1-minute orthostasis. Increase of mean arterial pressure as compared to the orthostasis test before medication was on average 4.5 mmHg. CCC affected diastolic blood pressure after 1 minute of orthostasis in all dosages as compared to placebo. A statistically significant effect of the highest dose of 80 drops on diastolic blood pressure could be demonstrated after 1-, 3-, and 5-minute orthostasis. The hemodynamic findings of a stabilizing effect on arterial pressure in orthostasis corroborate the long-term medical experience with CCC and justify the indication orthostatic hypotension.

  2. Zero-Gravity Research Facility Drop Test (3/4)

    NASA Technical Reports Server (NTRS)

    1995-01-01

    An experiment vehicle plunges into the deceleration at the end of a 5.18-second drop in the Zero-Gravity Research Facility at NASA's Glenn Research Center. The Zero-Gravity Research Facility was developed to support microgravity research and development programs that investigate various physical sciences, materials, fluid physics, and combustion and processing systems. Payloads up to one-meter in diameter and 455 kg in weight can be accommodated. The facility has a 145-meter evacuated shaft to ensure a disturbance-free drop. This is No. 3 of a sequence of 4 images. (Credit: NASA/Glenn Research Center)

  3. The impact of parity on life course blood pressure trajectories: the HUNT study in Norway.

    PubMed

    Haug, Eirin B; Horn, Julie; Markovitz, Amanda Rose; Fraser, Abigail; Macdonald-Wallis, Corrie; Tilling, Kate; Romundstad, Pål Richard; Rich-Edwards, Janet Wilson; Åsvold, Bjørn Olav

    2018-01-24

    The drop in blood pressure during pregnancy may persist postpartum, but the impact of pregnancy on blood pressure across the life course is not known. In this study we examined blood pressure trajectories for women in the years preceding and following pregnancy and compared life course trajectories of blood pressure for parous and nulliparous women. We linked information on all women who participated in the population-based, longitudinal HUNT Study, Norway with pregnancy information from the Medical Birth Registry of Norway. A total of 23,438 women were included with up to 3 blood pressure measurements per woman. Blood pressure trajectories were compared using a mixed effects linear spline model. Before first pregnancy, women who later gave birth had similar mean blood pressure to women who never gave birth. Women who delivered experienced a drop after their first birth of - 3.32 mmHg (95% CI, - 3.93, - 2.71) and - 1.98 mmHg (95% CI, - 2.43, - 1.53) in systolic and diastolic blood pressure, respectively. Subsequent pregnancies were associated with smaller reductions. These pregnancy-related reductions in blood pressure led to persistent differences in mean blood pressure, and at age 50, parous women still had lower systolic (- 1.93 mmHg; 95% CI, - 3.33, - 0.53) and diastolic (- 1.36 mmHg; 95% CI, - 2.26, - 0.46) blood pressure compared to nulliparous women. The findings suggest that the first pregnancy and, to a lesser extent, successive pregnancies are associated with lasting and clinically relevant reductions in systolic and diastolic blood pressure.

  4. Is drop-out from obesity treatment a predictable and preventable event?

    PubMed Central

    2014-01-01

    Background Attrition is an important but understudied issue that plays a vital role in the successful treatment of obesity. To date, most studies focusing on attrition rates and/or its predictors have been based on pretreatment data routinely collected for other purposes. Our study specifically aims at identifying the predictors of drop-out focusing on empirically or theoretically-based factors. Methods We conducted a retrospective observational study in an academic outpatient clinical nutrition service in Pavia, Italy. We examined a total of 98 adult obese patients (36 males, 62 females) who underwent a 6-month dietary behavioral weight-loss treatment at our Center. Pre-treatment and treatment-related variables were collected or calculated from clinical charts in order to discriminate those subjects who completed treatment from those who abandoned it before its completion. Multivariable regression analysis was used to identify the independent predictors of drop-out. Results The drop-out rates were 21% at 1 month and 57% at 6 months. Compared with completers, noncompleters were significantly younger in terms of age at first dieting attempt (24.0 ± 10.7 vs. 31.3 ± 11.2 years, P = 0.005), had lower diastolic blood pressure (87.8 ± 9.7 vs. 92.7 ± 11.4 mmHg, P = 0.022), had a lower baseline body fat percentage (38.5 ± 6.4 vs. 41.2 ± 4.4% weight, P = 0.015), and had a lower percentage of early weight loss (-1.8 ± 1.8% vs. -3.1 ± 2.1%, P = 0.035). Moreover, noncompleters significantly differed from completers with regard to type of referral (34.1% vs. 53.3% sent by a physician, P = 0.036) and SCL-90 anger-hostility subscale (0.83 ± 0.72 vs. 0.53 ± 0.51, P = 0.022). A multivariable logistic regression analysis including pre-treatment variables showed that body fat percentage (P = 0.030) and SCL-90 anger-hostility subscale (P = 0.021) were independently associated with attrition. In a multivariable model considering both pre-treatment and treatment-related factors, attrition was found to be independently related to the age at first dieting attempt (P = 0.016) and the achievement of early weight loss (P = 0.029). Conclusions Our data confirm that psychopathological tracts, early dieting attempts, and a poor initial treatment response are key independent predictors of drop-out from obesity treatment. PMID:24490952

  5. Water Impact Test and Simulation of a Composite Energy Absorbing Fuselage Section

    NASA Technical Reports Server (NTRS)

    Fasanella, Edwin L.; Jackson, Karen E.; Sparks, Chad; Sareen, Ashish

    2003-01-01

    In March 2002, a 25-ft/s vertical drop test of a composite fuselage section was conducted onto water. The purpose of the test was to obtain experimental data characterizing the structural response of the fuselage section during water impact for comparison with two previous drop tests that were performed onto a rigid surface and soft soil. For the drop test, the fuselage section was configured with ten 100-lb. lead masses, five per side, that were attached to seat rails mounted to the floor. The fuselage section was raised to a height of 10-ft. and dropped vertically into a 15-ft. diameter pool filled to a depth of 3.5-ft. with water. Approximately 70 channels of data were collected during the drop test at a 10-kHz sampling rate. The test data were used to validate crash simulations of the water impact that were developed using the nonlinear, explicit transient dynamic codes, MSC.Dytran and LS-DYNA. The fuselage structure was modeled using shell and solid elements with a Lagrangian mesh, and the water was modeled with both Eulerian and Lagrangian techniques. The fluid-structure interactions were executed using the fast general coupling in MSC.Dytran and the Arbitrary Lagrange-Euler (ALE) coupling in LS-DYNA. Additionally, the smooth particle hydrodynamics (SPH) meshless Lagrangian technique was used in LS-DYNA to represent the fluid. The simulation results were correlated with the test data to validate the modeling approach. Additional simulation studies were performed to determine how changes in mesh density, mesh uniformity, fluid viscosity, and failure strain influence the test-analysis correlation.

  6. In vitro comparison of Günther Tulip and Celect filters: testing filtering efficiency and pressure drop.

    PubMed

    Nicolas, M; Malvé, M; Peña, E; Martínez, M A; Leask, R

    2015-02-05

    In this study, the trapping ability of the Günther Tulip and Celect inferior vena cava filters was evaluated. Thrombus capture rates of the filters were tested in vitro in horizontal position with thrombus diameters of 3 and 6mm and tube diameter of 19mm. The filters were tested in centered and tilted positions. Sets of 30 clots were injected into the model and the same process was repeated 20 times for each different condition simulated. Pressure drop experienced along the system was also measured and the percentage of clots captured was recorded. The Günther Tulip filter showed superiority in all cases, trapping almost 100% of 6mm clots both in an eccentric and tilted position and trapping 81.7% of the 3mm clots in a centered position and 69.3% in a maximum tilted position. The efficiency of all filters tested decreased as the size of the embolus decreased and as the filter was tilted. The injection of 6 clots raised the pressure drop to 4.1mmHg, which is a reasonable value that does not cause the obstruction of blood flow through the system. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. CPAS Preflight Drop Test Analysis Process

    NASA Technical Reports Server (NTRS)

    Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.

    2015-01-01

    Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.

  8. Binary Colloidal Alloy Test-5: Three-Dimensional Melt

    NASA Technical Reports Server (NTRS)

    Yodh, Arjun G.

    2008-01-01

    Binary Colloidal Alloy Test - 5: Three-Dimensional Melt (BCAT-5-3DMelt) photographs initially randomized colloidal samples in microgravity to determine their resulting structure over time. BCAT-5-3D-Melt will allow the scientists to capture the kinetics (evolution) of their samples, as well as the final equilibrium state of each sample. BCAT-5-3D-Melt will look at the mechanisms of melting using three-dimensional temperature sensitive colloidal crystals. Results will help scientists develop fundamental physics concepts previously shadowed by the effects of gravity.

  9. 40 CFR Figure C-1 to Subpart C of... - Suggested Format for Reporting Test Results for Methods for SO 2, CO, O 3, NO 2

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Results for Methods for SO 2, CO, O 3, NO 2 C Figure C-1 to Subpart C of Part 53 Protection of Environment... Pt. 53, Subpt. C, Fig. C-1 Figure C-1 to Subpart C of Part 53—Suggested Format for Reporting Test... Difference Table C-1 spec. Pass or fail Low 1 ____ ppm 2 to ____ ppm 3 4 5 6 Medium 1 ____ ppm 2 to ____ ppm...

  10. 40 CFR Figure C-1 to Subpart C of... - Suggested Format for Reporting Test Results for Methods for SO 2, CO, O 3, NO 2

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Results for Methods for SO 2, CO, O 3, NO 2 C Figure C-1 to Subpart C of Part 53 Protection of Environment... Pt. 53, Subpt. C, Fig. C-1 Figure C-1 to Subpart C of Part 53—Suggested Format for Reporting Test... Difference Table C-1 spec. Pass or fail Low 1 ____ ppm 2 to ____ ppm 3 4 5 6 Medium 1 ____ ppm 2 to ____ ppm...

  11. 40 CFR Figure C-1 to Subpart C of... - Suggested Format for Reporting Test Results for Methods for SO 2, CO, O 3, NO 2

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Results for Methods for SO 2, CO, O 3, NO 2 C Figure C-1 to Subpart C of Part 53 Protection of Environment... Pt. 53, Subpt. C, Fig. C-1 Figure C-1 to Subpart C of Part 53—Suggested Format for Reporting Test... Difference Table C-1 spec. Pass or fail Low 1 ____ ppm 2 to ____ ppm 3 4 5 6 Medium 1 ____ ppm 2 to ____ ppm...

  12. 40 CFR Figure C-1 to Subpart C of... - Suggested Format for Reporting Test Results for Methods for SO 2, CO, O 3, NO 2

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Results for Methods for SO 2, CO, O 3, NO 2 C Figure C-1 to Subpart C of Part 53 Protection of Environment... Pt. 53, Subpt. C, Fig. C-1 Figure C-1 to Subpart C of Part 53—Suggested Format for Reporting Test... Difference Table C-1 spec. Pass or fail Low 1 ____ ppm 2 to ____ ppm 3 4 5 6 Medium 1 ____ ppm 2 to ____ ppm...

  13. Opening Loads Analyses for Various Disk-Gap-Band Parachutes

    NASA Technical Reports Server (NTRS)

    Cruz, J. R.; Kandis, M.; Witkowski, A.

    2003-01-01

    Detailed opening loads data is presented for 18 tests of Disk-Gap-Band (DGB) parachutes of varying geometry with nominal diameters ranging from 43.2 to 50.1 ft. All of the test parachutes were deployed from a mortar. Six of these tests were conducted via drop testing with drop test vehicles weighing approximately 3,000 or 8,000 lb. Twelve tests were conducted in the National Full-Scale Aerodynamics Complex 80- by 120-foot wind tunnel at the NASA Ames Research Center. The purpose of these tests was to structurally qualify the parachute for the Mars Exploration Rover mission. A key requirement of all tests was that peak parachute load had to be reached at full inflation to more closely simulate the load profile encountered during operation at Mars. Peak loads measured during the tests were in the range from 12,889 to 30,027 lb. Of the two test methods, the wind tunnel tests yielded more accurate and repeatable data. Application of an apparent mass model to the opening loads data yielded insights into the nature of these loads. Although the apparent mass model could reconstruct specific tests with reasonable accuracy, the use of this model for predictive analyses was not accurate enough to set test conditions for either the drop or wind tunnel tests. A simpler empirical model was found to be suitable for predicting opening loads for the wind tunnel tests to a satisfactory level of accuracy. However, this simple empirical model is not applicable to the drop tests.

  14. Eosinophils, pruritus and psoriasis: effects of treatment with etretinate or cyclosporin-A.

    PubMed

    Schopf, R E; Hultsch, T; Lotz, J; Bräutigam, M

    1998-11-01

    The antipsoriatic drugs cyclosporin A (CyA) and etretinate have been found to influence proinflammatory eosinophilic leukocytes and pruritus. We compared the number of blood eosinophils, concentration of serum eosinophil cationic protein (ECP), and pruritus in patients with psoriasis treated with either CyA or etretinate. Patients with psoriasis vulgaris were randomly assigned to treatment for 10 weeks with either CyA (n = 21) or etretinate (n = 10). The psoriasis area-and-severity index (PASI-score) and pruritus (according to a 0-3 scale) served as clinical parameters, the blood esosinophil counts (Coulter Counter) and the serum ECP (RIA, Pharmacia) as laboratory parameters. After CyA treatment the PASI-score amounted to 24 +/- 4%, after etretinate to 56 +/- 6% of the initial values (mean +/- SEM). One week after CyA treatment, esosinophils dropped from 190 +/- 21 to 137 +/- 16/microliter (P = 0.038, Wilcoxon test), after 10 weeks to 127 +/- 18/microliter (P = 0.006). By contrast, under etretinate blood eosinophil counts only changed marginally. Before treatment, ECP concentrations of 15.71 +/- 1.30 (CyA) and 15.3 +/- 5.53 micrograms/l (etretinate) were measured (normal range 3-16 micrograms/l), ECP remained constant under both CyA and etretinate or tended to increase after 10 weeks; about 50% of the patients exhibited elevated ECP concentrations. Pruritus diminished more with CyA than etretinate therapy. PASI-scores and pruritus were directly proportional. We conclude that treatment of psoriasis with CyA leads to a rapid drop of blood eosinophils and that the activation state of eosinophils does not decrease after antipsoriatic treatment. Pruritus in psoriasis is coupled to disease severity. The underlying antipsoriatic mechanisms of CyA may be linked to lowering the number of blood eosinophils.

  15. An upright eyedrop bottle: accuracy, usage of excess drops, and contamination compared to a conventional bottle.

    PubMed

    Davies, Isaiah J; Brown, Ninita H; Wen, Joanne C; Stinnett, Sandra S; Kubelick, Kelsey; Patel, Roma P; Benokraitis, Kristin L; Greene, Latoya; Cheek, Curry; Muir, Kelly W

    2016-01-01

    This study tested the feasibility of using an upright eyedrop bottle (UEB), a device designed to assist patients with eyedrop placement without reclining their head. Experienced eyedrop users were enrolled who answered "yes" to the question, "Do you ever have trouble getting your eyedrops in?" After being shown a multimedia presentation and answering a questionnaire regarding eyedrop usage, participants were observed instilling eyedrops. Participants were instructed to instill a single eyedrop in each eye with both a standard bottle and the UEB. They repeated this process three times. With each trial, the amount of time taken to instill drops was recorded, as well as whether a drop landed in the eye (accuracy), if excess drops were used, and if the bottle tip was contaminated. Forty participants were enrolled, with an average age of 72.4±8.9 years; the majority were females (24 females). Thirty-four participants had been using eyedrops for at least 1 year. The time required to instill eyedrops was significantly less with the UEB in the second and third trials. There was no difference in accuracy between the conventional bottle and the UEB in the left or right eye in any trials. Significantly more participants used excess number of drops while using the conventional bottle in both the left and right eyes in all three trials. The bottle tip was never contaminated with the UEB. Depending on the trial and the eye, the conventional bottle was contaminated by between 42% and 53% of participants. The UEB has the potential to assist patients with eyedrop placement. Although there was no difference in accuracy between the UEB and the conventional bottle, the UEB was associated with less use of excess drops and less contamination of the bottle tip, compared to the conventional bottle.

  16. Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

    NASA Astrophysics Data System (ADS)

    Liu, Jinglong; Zhao, Xianqiao; Hou, Fanjun; Wu, Xiaowu; Wang, Feng; Hu, Zhihong; Yang, Xinsen

    2018-01-01

    Steam and water pressure drop is one of the most important characteristics in the boiler performance test. As the measuring points are not in the guaranteed position and the test condition fluctuation exsits, the pressure drop test of steam and water system has the deviation of measuring point position and the deviation of test running parameter. In order to get accurate pressure drop of steam and water system, the corresponding correction should be carried out. This paper introduces the correction method of steam and water pressure drop in boiler performance test.

  17. Space Shuttle Solid Rocket Booster decelerator subsystem - Air drop test vehicle/B-52 design

    NASA Technical Reports Server (NTRS)

    Runkle, R. E.; Drobnik, R. F.

    1979-01-01

    The air drop development test program for the Space Shuttle Solid Rocket Booster Recovery System required the design of a large drop test vehicle that would meet all the stringent requirements placed on it by structural loads, safety considerations, flight recovery system interfaces, and sequence. The drop test vehicle had to have the capability to test the drogue and the three main parachutes both separately and in the total flight deployment sequence and still be low-cost to fit in a low-budget development program. The design to test large ribbon parachutes to loads of 300,000 pounds required the detailed investigation and integration of several parameters such as carrier aircraft mechanical interface, drop test vehicle ground transportability, impact point ground penetration, salvageability, drop test vehicle intelligence, flight design hardware interfaces, and packaging fidelity.

  18. Lighting with Less Wattage.

    ERIC Educational Resources Information Center

    American School and University, 1981

    1981-01-01

    Schools in Wilton (Connecticut) cut electric consumption 39 percent by replacing existing lamps with new types of energy saving lamps. Fuel oil consumption dropped 53 percent largely through attention paid to the operation of boilers and oil burners. (Author/MLF)

  19. Evaluation of ENEPIG and Immersion Silver Surface Finishes Under Drop Loading

    NASA Astrophysics Data System (ADS)

    Pearl, Adam; Osterman, Michael; Pecht, Michael

    2016-01-01

    The effect of printed circuit board surface finish on the drop loading reliability of ball grid array (BGA) solder interconnects has been examined. The finishes examined include electroless nickel/electroless palladium/immersion gold (ENEPIG) and immersion silver (ImAg). For the ENEPIG finish, the effect of the Pd plating layer thickness was evaluated by testing two different thicknesses: 0.05 μm and 0.15 μm. BGA components were assembled onto the boards using either eutectic Sn-Pb or Sn-3.0Ag-0.5Cu (SAC305) solder. Prior to testing, the assembled boards were aged at 100°C for 24 h or 500 h. The boards were then subjected to multiple 1500-g drop tests. Failure analysis indicated the primary failure site for the BGAs to be the solder balls at the board-side solder interface. Cratering of the board laminate under the solder-attached pads was also observed. In all cases, isothermal aging reduced the number of drops to failure. The components soldered onto the boards with the 0.15- μm-Pd ENEPIG finish with the SAC305 solder had the highest characteristic life, at 234 drops to failure, compared with the other finish-solder combinations.

  20. Generation of Homogenous Three-Dimensional Pancreatic Cancer Cell Spheroids Using an Improved Hanging Drop Technique

    PubMed Central

    Ware, Matthew J.; Colbert, Kevin; Keshishian, Vazrik; Ho, Jason; Corr, Stuart J.; Curley, Steven A.

    2016-01-01

    In vitro characterization of tumor cell biology or of potential anticancer drugs is usually performed using tumor cell lines cultured as a monolayer. However, it has been previously shown that three-dimensional (3D) organization of the tumor cells is important to provide insights on tumor biology and transport of therapeutics. Several methods to create 3D tumors in vitro have been proposed, with hanging drop technique being the most simple and, thus, most frequently used. However, in many cell lines this method has failed to form the desired 3D tumor structures. The aim of this study was to design and test an easy-to-use and highly reproducible modification of the hanging drop method for tumor sphere formation by adding methylcellulose polymer. Most pancreatic cancer cells do not form cohesive and manageable spheres when the original hanging drop method is used, thus we investigated these cell lines for our modified hanging drop method. The spheroids produced by this improved technique were analyzed by histology, light microscopy, immunohistochemistry, and scanning electron microscopy. Results show that using the proposed simple method; we were able to produce uniform spheroids for all five of the tested human pancreatic cancer cell lines; Panc-1, BxPC-3, Capan-1, MiaPaCa-2, and AsPC-1. We believe that this method can be used as a reliable and reproducible technique to make 3D cancer spheroids for use in tumor biology research and evaluation of therapeutic responses, and for the development of bio-artificial tissues. PMID:26830354

  1. Generation of Homogenous Three-Dimensional Pancreatic Cancer Cell Spheroids Using an Improved Hanging Drop Technique.

    PubMed

    Ware, Matthew J; Colbert, Kevin; Keshishian, Vazrik; Ho, Jason; Corr, Stuart J; Curley, Steven A; Godin, Biana

    2016-04-01

    In vitro characterization of tumor cell biology or of potential anticancer drugs is usually performed using tumor cell lines cultured as a monolayer. However, it has been previously shown that three-dimensional (3D) organization of the tumor cells is important to provide insights on tumor biology and transport of therapeutics. Several methods to create 3D tumors in vitro have been proposed, with hanging drop technique being the most simple and, thus, most frequently used. However, in many cell lines this method has failed to form the desired 3D tumor structures. The aim of this study was to design and test an easy-to-use and highly reproducible modification of the hanging drop method for tumor sphere formation by adding methylcellulose polymer. Most pancreatic cancer cells do not form cohesive and manageable spheres when the original hanging drop method is used, thus we investigated these cell lines for our modified hanging drop method. The spheroids produced by this improved technique were analyzed by histology, light microscopy, immunohistochemistry, and scanning electron microscopy. Results show that using the proposed simple method; we were able to produce uniform spheroids for all five of the tested human pancreatic cancer cell lines; Panc-1, BxPC-3, Capan-1, MiaPaCa-2, and AsPC-1. We believe that this method can be used as a reliable and reproducible technique to make 3D cancer spheroids for use in tumor biology research and evaluation of therapeutic responses, and for the development of bio-artificial tissues.

  2. Flowrate testing of the bag filter LANCS-BOP 6CPVC-1.5-2SPVC (LANCS Industries) at 1 psig

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Murray E.; Currie, Karissa Lyn; Berg, Charlotte Katherine

    2016-09-13

    The air flowrate through a flexible HEPA grade filter (Part LANCS-BOP 6CPVC-1.5-2SPVC www.lancsindustries.com) was measured at 48 ALPM for a differential pressure drop of 1.0 psig (28 inWC, 7.0 kPa). These filters are rated by the manufacturer to have a flowrate of 3 ALPM at a differential pressure drop of 1 inWC (0.25 kPa). The Los Alamos National Laboratory Aerosol Engineering Facility used one of their test rigs (originally developed to measure the pressure drop in capsule HEPA filters) to measure the airflow through the LANCS bag filter.

  3. Comparison of the hanging-drop technique and running-drip method for identifying the epidural space in dogs.

    PubMed

    Martinez-Taboada, Fernando; Redondo, José I

    2017-03-01

    To compare the running-drip and hanging-drop techniques for locating the epidural space in dogs. Prospective, randomized, clinical trial. Forty-five healthy dogs requiring epidural anaesthesia. Dogs were randomized into four groups and administered epidural anaesthesia in sternal (S) or lateral (L) recumbency. All blocks were performed by the same person using Tuohy needles with either a fluid-prefilled hub (HDo) or connected to a drip set attached to a fluid bag elevated 60 cm (RDi). The number of attempts, 'pop' sensation, clear drop aspiration or fluid dripping, time to locate the epidural space (TTLES) and presence of cerebrospinal fluid (CSF) were recorded. A morphine-bupivacaine combination was injected after positive identification. The success of the block was assessed by experienced observers based on perioperative usage of rescue analgesia. Data were checked for normality. Binomial variables were analysed with the chi-squared or Fisher's exact test as appropriate. Non-parametric data were analysed using Kruskal-Wallis and Mann-Whitney tests. Normal data were studied with an anova followed by a Tukey's means comparison for groups of the same size. A p-value of < 0.05 was considered to indicate statistical significance. Lateral recumbency HDo required more attempts (six of 11 dogs required more than one attempt) than SRDi (none of 11 dogs) (p = 0.0062). Drop aspiration was observed more often in SHDo (nine of 11 dogs) than in LHDo (two of 11 dogs) (p = 0.045). Mean (range) TTLES was longer in LHDo [47 (18-82) seconds] than in SHDo [20 (14-79) seconds] (p = 0.006) and SRDi [(34 (17-53) seconds] (p = 0.038). There were no differences in 'pop' sensation, presence of CSF, rescue analgesia or pain scores between the groups. The running-drip method is a useful and fast alternative technique for identifying the epidural space in dogs. The hanging-drop technique in lateral recumbency was more difficult to perform than the other methods, requiring more time and attempts. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  4. NF-kappaB and p53 are the dominant apoptosis-inducing transcription factors elicited by the HIV-1 envelope.

    PubMed

    Perfettini, Jean-Luc; Roumier, Thomas; Castedo, Maria; Larochette, Nathanael; Boya, Patricia; Raynal, Brigitte; Lazar, Vladimir; Ciccosanti, Fabiola; Nardacci, Roberta; Penninger, Josef; Piacentini, Mauro; Kroemer, Guido

    2004-03-01

    The coculture of cells expressing the HIV-1 envelope glycoprotein complex (Env) with cells expressing CD4 results into cell fusion, deregulated mitosis, and subsequent cell death. Here, we show that NF-kappaB, p53, and AP1 are activated in Env-elicited apoptosis. The nuclear factor kappaB (NF-kappaB) super repressor had an antimitotic and antiapoptotic effect and prevented the Env-elicited phosphorylation of p53 on serine 15 and 46, as well as the activation of AP1. Transfection with dominant-negative p53 abolished apoptosis and AP1 activation. Signs of NF-kappaB and p53 activation were also detected in lymph node biopsies from HIV-1-infected individuals. Microarrays revealed that most (85%) of the transcriptional effects of HIV-1 Env were blocked by the p53 inhibitor pifithrin-alpha. Macroarrays led to the identification of several Env-elicited, p53-dependent proapoptotic transcripts, in particular Puma, a proapoptotic "BH3-only" protein from the Bcl-2 family known to activate Bax/Bak. Down modulation of Puma by antisense oligonucleotides, as well as RNA interference of Bax and Bak, prevented Env-induced apoptosis. HIV-1-infected primary lymphoblasts up-regulated Puma in vitro. Moreover, circulating CD4+ lymphocytes from untreated, HIV-1-infected donors contained enhanced amounts of Puma protein, and these elevated Puma levels dropped upon antiretroviral therapy. Altogether, these data indicate that NF-kappaB and p53 cooperate as the dominant proapoptotic transcription factors participating in HIV-1 infection.

  5. Reproducibility of and sex differences in common orthopaedic ankle and foot tests in runners

    PubMed Central

    2014-01-01

    Background For future etiologic cohort studies in runners it is important to identify whether (hyper)pronation of the foot, decreased ankle joint dorsiflexion (AJD) and the degree of the extension of the first Metatarsophalangeal joint (MTP1) are risk factors for running injuries and to determine possible sex differences. These parameters are frequently determined with the navicular drop test (NDT) Stance and Single Limb-Stance, the Ankle Joint Dorsiflexion-test, and the extension MTP1-test in a healthy population. The aim of this clinimetric study was to determine the reproducibility of these three orthopaedic tests in runners, using minimal equipment in order to make them applicable in large cohort studies. Furthermore, we aimed to determine possible sex differences of these tests. Methods The three orthopaedic tests were administered by two sports physiotherapists in a group of 42 (22 male and 20 female) recreational runners. The intra-class correlation (ICC) for interrater and intrarater reliability and the standard error of measurement (SEM) were calculated. Bland and Altman plots were used to determine the 95% limits of agreements (LOAs). Furthermore, the difference between female and male runners was determined. Results The ICC’s of the NDT were in the range of 0.37 to 0.45, with a SEM in the range of 2.5 to 5 mm. The AJD-test had an ICC of 0.88 and 0.86 (SEM 2.4° and 8.7°), with a 95% LOA of -6.0° to 6.3° and -5.3° to 7.9°, and the MTP1-test had an ICC of 0.42 and 0.62 (SEM 34.4° and 9.9°), with a 95% LOA of -30.9° to 20.7° and -20° to 17.8° for the interrater and intrarater reproducibility, respectively. Females had a significantly (p < 0.05) lower navicular drop score and higher range of motion in extension of the MTP1, but no sex differences were found for ankle dorsiflexion (p ≥ 0.05). Conclusion The reproducibility for the AJD test in runners is good, whereas that of the NDT and extension MTP1 was moderate or low. We found a difference in NDT and MTP1 mobility between female and male runners, however this needs to be established in a larger study with more reliable test procedures. PMID:24886037

  6. Switchable polarity solvent for liquid phase microextraction of Cd(II) as pyrrolidinedithiocarbamate chelates from environmental samples.

    PubMed

    Yilmaz, Erkan; Soylak, Mustafa

    2015-07-30

    A switchable polarity solvent was synthesized from triethylamine (TEA)/water/CO2 (Dry ice) via proton transfer reaction has been used for the microextraction of cadmium(II) as pyrrolidinedithiocarbamate (APDC) chelate. Cd(II)-APDC chelate was extracted into the switchable polarity solvent drops by adding 2 mL 10 M sodium hydroxide solution. Analytical parameters affecting the complex formation and microextraction efficiency such as pH, amount of ligand, volume of switchable polarity solvent and NaOH, sample volume were optimized. The effects of foreign ions were found tolerably. Under optimum conditions, the detection limit was 0.16 μg L(-1) (3Sb/m, n = 7) and the relative standard deviation was 5.4% (n = 7). The method was validated by the analysis of certified reference materials (TMDA-51.3 fortified water, TMDA-53.3 fortified water and SPS-WW2 waste water, 1573a Tomato Leaves and Oriental Basma Tobacco Leaves (INCT-OBTL-5)) and addition/recovery tests. The method was successfully applied to determination of cadmium contents of water, vegetable, fruit and cigarette samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Integration of pyrolysis and anaerobic digestion--use of aqueous liquor from digestate pyrolysis for biogas production.

    PubMed

    Hübner, Tobias; Mumme, Jan

    2015-05-01

    Anaerobic digestion of aqueous pyrolysis liquor derived from pyrolysis of solid digestate was tested in batch mode using an un-adapted inoculum. Three pyrolysis liquors produced at 330°C, 430°C and 530°C in four COD-based concentrations of 3, 6, 12 and 30 g L(-1) were investigated. The three lower concentrations showed considerable biogas production, whereas the 30 g L(-1) dosage caused process inhibition. The highest methane yield of 199.1±18.5 mL g(COD)(-1) (COD removal: 56.9±5.3%) was observed for the 330°C pyrolysis liquor, followed by the 430°C sample with only slightly lower values. The 530°C sample dropped to a yield of 129.3±19.7 mL g(COD)(-1) (COD removal: 36.9±5.6%). Most VOCs contained in the pyrolysis liquor (i.e. furfural, phenol, catechol, guaiacol, and levoglucosan) were reduced below detection limit (cresol by 10-60%). Consequently, integrated pyrolysis and anaerobic digestion in addition to thermochemical conversion of digestate also promises bioconversion of pyrolysis liquors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. 40 CFR Table C-3 to Subpart C of... - Test Specifications for Pb in TSP and Pb in PM 10 Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Specifications for Pb in TSP and Pb in PM 10 Methods C Table C-3 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL..., Subpt. C, Table C-3 Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM 10...

  9. 40 CFR Table C-3 to Subpart C of... - Test Specifications for Pb in TSP and Pb in PM 10 Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Specifications for Pb in TSP and Pb in PM 10 Methods C Table C-3 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL..., Subpt. C, Table C-3 Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM 10...

  10. 40 CFR Table C-3 to Subpart C of... - Test Specifications for Pb in TSP and Pb in PM10 Methods

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test Specifications for Pb in TSP and Pb in PM10 Methods C Table C-3 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL..., Subpt. C, Table C-3 Table C-3 to Subpart C of Part 53—Test Specifications for Pb in TSP and Pb in PM10...

  11. 40 CFR Figure C-1 to Subpart C of... - Suggested Format for Reporting Test Results for Methods for SO 2, CO, O 3, NO 2

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Results for Methods for SO 2, CO, O 3, NO 2 C Figure C-1 to Subpart C of Part 53 Protection of Environment... Pt. 53, Subpt. C, Fig. C-1 Figure C-1 to Subpart C of Part 53—Suggested Format for Reporting Test... Difference Table C-1 spec. Pass or fail Low 1 ____ pPM 2 to ____ pPM 3 4 5 6 Medium 1 ____ pPM 2 to ____ pPM...

  12. Internally damped, self-arresting vertical drop-weight impact test apparatus

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R. (Inventor); Prasad, Chunchu B. (Inventor); Waters, Jr., William A. (Inventor); Stockum, Robert W. (Inventor); Walter, Manfred A. (Inventor)

    1996-01-01

    A vertical dropped-weight impact test machine has a dropped-weight barrel vertically supported on upper and lower support brackets. The dropped-weight barrel is chambered to receive a dropped-weight assembly having a latch pin at its upper end, a damping unit in the middle, and a tup at its lower end. The tup is adapted for gathering data during impact testing. The latch pin releasably engages a latch pin coupling assembly. The latch pin coupling assembly is attached to a winch via a halyard for raising and lowering the dropped-weight assembly. The lower end of the dropped-weight barrel is provided with a bounce-back arresting mechanism which is activated by the descending passage of the dropped-weight assembly. After striking the specimen, the dropped-weight assembly rebounds vertically and is caught by the bounce-back arresting mechanism. The damping unit of the dropped-weight assembly serves to dissipate energy from the rebounding dropped-weight assembly and prevents the dropped-weight assembly from rebounding from the self-arresting mechanism.

  13. Internally damped, self-arresting vertical drop-weight impact test apparatus

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R. (Inventor); Prasad, Chunchu B. (Inventor); Waters, Jr., William A. (Inventor); Stockum, Robert W. (Inventor); Water, Manfred A. (Inventor)

    1995-01-01

    A vertical dropped-weight impact test machine has a dropped-weight barrel vertically supported on upper and lower support brackets. The dropped-weight barrel is chambered to receive a dropped-weight assembly having a latch pin at its upper end, a damping unit in the middle, and a tup at its lower end. The tup is adapted for gathering data during impact testing. The latch pin releasably engages a latch pin coupling assembly. The latch pin coupling assembly is attached to a winch via a halyard for raising and lowering the dropped-weight assembly. The lower end of the dropped-weight barrel is provided with a bounce-back arresting mechanism which is activated by the descending passage of the dropped-weight assembly. After striking the specimen, the dropped-weight assembly rebounds vertically and is caught by the bounce-back arresting mechanism. The damping unit of the dropped-weight assembly serves to dissipate energy from the rebounding dropped-weight assembly and prevents the dropped-weight assembly from rebounding from the self-arresting mechanism.

  14. Vertical drop test of a transport fuselage center section including the wheel wells

    NASA Technical Reports Server (NTRS)

    Williams, M. S.; Hayduk, R. J.

    1983-01-01

    A Boeing 707 fuselage section was drop tested to measure structural, seat, and anthropomorphic dummy response to vertical crash loads. The specimen had nominally zero pitch, roll and yaw at impact with a sink speed of 20 ft/sec. Results from this drop test and other drop tests of different transport sections will be used to prepare for a full-scale crash test of a B-720.

  15. Manchester iStent study: early results from a prospective UK case series.

    PubMed

    Patel, Ilesh; de Klerk, Timothy A; Au, Leon

    2013-01-01

    To evaluate the 6-month efficacy and safety of the iStent microtrabecular bypass stent in patients with open-angle glaucoma. A prospective, uncontrolled, interventional case series. Forty-four eyes with open-angle glaucoma were reported. All subjects underwent ab interno implantation of a single iStent together with (n = 40) or without (n = 4) cataract surgery. Patients were assessed at postoperative week 1, months 1 and 3, and quarterly, thereafter. Data collected included visual acuity, intraocular pressure measurement using Goldmann tonometry, number of glaucoma medications, and number and type of complications. The mean age of the sample was 76.8 years. The mean duration since glaucoma diagnosis was 5.3 years (standard deviation 2.9 years). The mean visual acuity was 0.53 logMAR at baseline that improved to 0.23 at 6 months postoperatively. The mean baseline intraocular pressure was 21.1 mmHg, and this decreased significantly to 16.7 mmHg at 6 months (P < 0.01). The mean number of drops prescribed preoperatively was 2.3, which decreased to 0.6 at 6 months (P < 0.01). Sixty-six per cent of patients were drop-free at 6 months. One patient developed an hyphaema following surgery; no other adverse events were recorded. The iStent proved to be a safe and effective treatment for patients with open-angle glaucoma over our 6-month follow up period. Insertion resulted in a significant decrease in intraocular pressure as well as the number of topical antiglaucoma medications required for adequate intraocular pressure control. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  16. Environmental Assessment, Establishing a Drop Zone at the Energetic Materials Research and Testing Center in Socorro, New Mexico and Finding of No Significant Impact (FONSI)

    DTIC Science & Technology

    2007-11-07

    action is open space, and free of any residential or other structures . Biological Resources Minor impacts to vegetation and wildlife may occur from...mountains, rills, gullies, or other notable geologic features. There are no residences or other structures within the proposed drop zone. 3.2 Airspace...research, testing and training related to energetic materials. The land has also been used for livestock grazing. There are no structures on the

  17. Evaluation of wheelchair seating system crashworthiness: "drop hook"-type seat attachment hardware.

    PubMed

    Bertocci, G; Ha, D; Deemer, E; Karg, P

    2001-04-01

    To evaluate the crashworthiness of commercially available hardware that attaches seat surfaces to the wheelchair frame. A low cost static crashworthiness test procedure that simulates a frontal impact motor vehicle crash. Safety testing laboratory. Eleven unique sets of drop-hook hardware made of carbon steel (4), stainless steel (4), and aluminum (3). Replicated seat-loading conditions associated with a 20g/48 kph frontal impact. Test criterion for seat loading was 16,680 N (3750 lb). Failure load and deflection of seat surface. None of the hardware sets tested met the crashworthiness test criterion. All failed at less than 50% of the load that seating hardware could be exposed to in a 20g/48 kph frontal impact. The primary failure mode was excessive deformation, leading to an unstable seat support surface. Results suggest that commercially available seating drop hooks may be unable to withstand loading associated with a frontal crash and may not be the best option for use with transport wheelchairs.

  18. Crash Simulation of a Boeing 737 Fuselage Section Vertical Drop Test

    NASA Technical Reports Server (NTRS)

    Fasanella, Edwin L.; Jackson, Karen E.; Jones, Yvonne T.; Frings, Gary; Vu, Tong

    2004-01-01

    A 30-ft/s vertical drop test of a fuselage section of a Boeing 737 aircraft was conducted in October of 1999 at the FAA Technical Center in Atlantic City, NJ. This test was performed to evaluate the structural integrity of a conformable auxiliary fuel tank mounted beneath the floor and to determine its effect on the impact response of the airframe structure and the occupants. The test data were used to compare with a finite element simulation of the fuselage structure and to gain a better understanding of the impact physics through analytical/experimental correlation. To perform this simulation, a full-scale 3-dimensional finite element model of the fuselage section was developed using the explicit, nonlinear transient-dynamic finite element code, MSC.Dytran. The emphasis of the simulation was to predict the structural deformation and floor-level acceleration responses obtained from the drop test of the B737 fuselage section with the auxiliary fuel tank.

  19. Instruction and jump-landing kinematics in college-aged female athletes over time.

    PubMed

    Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I; Van Lunen, Bonnie L; Onate, James A

    2013-01-01

    Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box-drop-jump task, running-stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Randomized controlled clinical trial. Laboratory. Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Participants performed a box-drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box-drop-jump task and a running-stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. For the box-drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box-drop-jump task at posttest. For the running-stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks.

  20. Instruction and Jump-Landing Kinematics in College-Aged Female Athletes Over Time

    PubMed Central

    Etnoyer, Jena; Cortes, Nelson; Ringleb, Stacie I.; Van Lunen, Bonnie L.; Onate, James A.

    2013-01-01

    Context: Instruction can be used to alter the biomechanical movement patterns associated with anterior cruciate ligament (ACL) injuries. Objective: To determine the effects of instruction through combination (self and expert) feedback or self-feedback on lower extremity kinematics during the box–drop-jump task, running–stop-jump task, and sidestep-cutting maneuver over time in college-aged female athletes. Design: Randomized controlled clinical trial. Setting: Laboratory. Patients or Other Participants: Forty-three physically active women (age = 21.47 ± 1.55 years, height = 1.65 ± 0.08 m, mass = 63.78 ± 12.00 kg) with no history of ACL or lower extremity injuries or surgery in the 2 months before the study were assigned randomly to 3 groups: self-feedback (SE), combination feedback (CB), or control (CT). Intervention(s): Participants performed a box–drop-jump task for the pretest and then received feedback about their landing mechanics. After the intervention, they performed an immediate posttest of the box–drop-jump task and a running–stop-jump transfer test. Participants returned 1 month later for a retention test of each task and a sidestep-cutting maneuver. Kinematic data were collected with an 8-camera system sampled at 500 Hz. Main Outcome Measure(s): The independent variables were feedback group (3), test time (3), and task (3). The dependent variables were knee- and hip-flexion, knee-valgus, and hip- abduction kinematics at initial contact and at peak knee flexion. Results: For the box–drop-jump task, knee- and hip-flexion angles at initial contact were greater at the posttest than at the retention test (P < .001). At peak knee flexion, hip flexion was greater at the posttest than at the pretest (P = .003) and was greater at the retention test than at the pretest (P = .04); knee valgus was greater at the retention test than at the pretest (P = .03) and posttest (P = .02). Peak knee flexion was greater for the CB than the SE group (P = .03) during the box–drop-jump task at posttest. For the running–stop-jump task at the posttest, the CB group had greater peak knee flexion than the SE and CT (P ≤ .05). Conclusions: Our results suggest that feedback involving a combination of self-feedback and expert video feedback with oral instruction effectively improved lower extremity kinematics during jump-landing tasks. PMID:23672380

  1. The Failure Models of Lead Free Sn-3.0Ag-0.5Cu Solder Joint Reliability Under Low-G and High-G Drop Impact

    NASA Astrophysics Data System (ADS)

    Gu, Jian; Lei, YongPing; Lin, Jian; Fu, HanGuang; Wu, Zhongwei

    2017-02-01

    The reliability of Sn-3.0Ag-0.5Cu (SAC 305) solder joint under a broad level of drop impacts was studied. The failure performance of solder joint, failure probability and failure position were analyzed under two shock test conditions, i.e., 1000 g for 1 ms and 300 g for 2 ms. The stress distribution on the solder joint was calculated by ABAQUS. The results revealed that the dominant reason was the tension due to the difference in stiffness between the print circuit board and ball grid array, and the maximum tension of 121.1 MPa and 31.1 MPa, respectively, under both 1000 g or 300 g drop impact, was focused on the corner of the solder joint which was located in the outmost corner of the solder ball row. The failure modes were summarized into the following four modes: initiation and propagation through the (1) intermetallic compound layer, (2) Ni layer, (3) Cu pad, or (4) Sn-matrix. The outmost corner of the solder ball row had a high failure probability under both 1000 g and 300 g drop impact. The number of failures of solder ball under the 300 g drop impact was higher than that under the 1000 g drop impact. The characteristic drop values for failure were 41 and 15,199, respectively, following the statistics.

  2. Liquid and gelled sprays for mixing hypergolic propellants using an impinging jet injection system

    NASA Astrophysics Data System (ADS)

    James, Mark D.

    The characteristics of sprays produced by liquid rocket injectors are important in understanding rocket engine ignition and performance. The includes, but is not limited to, drop size distribution, spray density, drop velocity, oscillations in the spray, uniformity of mixing between propellants, and the spatial distribution of drops. Hypergolic ignition and the associated ignition delay times are also important features in rocket engines, providing high reliability and simplicity of the ignition event. The ignition delay time is closely related to the level and speed of mixing between a hypergolic fuel and oxidizer, which makes the injection method and conditions crucial in determining the ignition performance. Although mixing and ignition of liquid hypergolic propellants has been studied for many years, the processes for injection, mixing, and ignition of gelled hypergolic propellants are less understood. Gelled propellants are currently under investigation for use in rocket injectors to combine the advantages of solid and liquid propellants, although not without their own difficulties. A review of hypergolic ignition has been conducted for selected propellants, and methods for achieving ignition have been established. This research is focused on ignition using the liquid drop-on-drop method, as well as the doublet impinging jet injector. The events leading up to ignition, known as pre-ignition stage are discussed. An understanding of desirable ignition and combustion performance requires a study of the effects of injection, temperature, and ambient pressure conditions. A review of unlike-doublet impinging jet injection mixing has also been conducted. This includes mixing factors in reactive and non-reactive sprays. Important mixing factors include jet momentum, jet diameter and length, impingement angle, mass distribution, and injector configuration. An impinging jet injection system is presented using an electro-mechanically driven piston for injecting liquid and gelled hypergolic propellants. A calibration of the system is done with water in preparation for hypergolic injection, and characteristics of individual water and gelled JP-8 jets are studied at velocities in the range of 3 ft/s to 61 ft/s. The piston response is also analyzed to characterize the startup and steady state liquid jet velocities using orifices of 0.02" in diameter. Using this injection system, water and gelled JP-8 sprays are formed and compared across injection velocities of 30 ft/s to 121 ft/s. The comparison includes sheet shape and disintegration, total number of drops, drop size distributions, drop eccentricity, most populated drop bin size, and mean drop sizes. A test matrix for investigating the effects of mixing on ignition of MMH and IRFNA through different injection conditions are presented. First, water and IRFNA are injected to create a spray in the combustion chamber in order to verify effectiveness of test procedures and the test hardware. Next, injection of the hypergolic propellants MMH and IRFNA are done in accordance to the test matrix, although ignition was not observed as expected. These injections are followed by simple drop-on-drop tests to investigate propellant quality and ignition delay. Drop tests are performed with propellants IRFNA/MMH, and again with H2O2/Block 0 as possible propellant replacements for the proposed test plan.

  3. A three-dimensional in vitro HepG2 cells liver spheroid model for genotoxicity studies.

    PubMed

    Shah, Ume-Kulsoom; Mallia, Jefferson de Oliveira; Singh, Neenu; Chapman, Katherine E; Doak, Shareen H; Jenkins, Gareth J S

    2018-01-01

    The liver's role in metabolism of chemicals makes it an appropriate tissue for toxicity testing. Current testing protocols, such as animal testing and two-dimensional liver cell systems, offer limited resemblance to in vivo liver cell behaviour, in terms of gene expression profiles and metabolic competence; thus, they do not always accurately predict human toxicology. In vitro three-dimensional liver cell models offer an attractive alternative. This study reports on the development of a 3D liver model, using HepG2 cells, by a hanging-drop technique, with a focus on evaluating spheroid growth characteristics and suitability for genotoxicity testing. The cytokinesis-blocked micronucleus assay protocol was adapted to enable micronucleus (MN) detection in the 3D spheroid models. This involved evaluating the difference between hanging vs non-hanging drop positions for dosing of the test agents and comparison of automated Metafer scoring with manual scoring for MN detection in HepG2 spheroids. The initial seeding density, used for all experiments, was 5000 cells/20 μl drop hanging spheroids, harvested on day 4, with >75% cell viability. Albumin secretion (7.8 g/l) and both CYP1A1 and CYP1A2 gene expression were highest in the 3D environment at day 4. Exposure to metabolically activated genotoxicants for 24 h resulted in a 6-fold increase in CYP1A1 enzyme activity (3 μM B[a]P) and a 30-fold increase in CYP1A2 enzyme activity (5 μM PhIP) in 3D hanging spheroids. MN inductions in response to B[a]P or PhIP were 2-fold and 3-fold, respectively, and were greater in 3D hanging spheroids than in 2D format, showing that hanging spheroids are more sensitive to genotoxic agents. HepG2 hanging-drop spheroids are an exciting new alternative system for genotoxicity studies, due to their improved structural and physiological properties, relative to 2D cultures. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Vertical Force-deflection Characteristics of a Pair of 56-inch-diameter Aircraft Tires from Static and Drop Tests with and Without Prerotation

    NASA Technical Reports Server (NTRS)

    Smiley, Robert F; Horne, Walter B

    1957-01-01

    The vertical force-deflection characteristics were experimentally determined for a pair of 56-inch-diameter tires under static and drop-test conditions with and without prerotation. For increasing force, the tires were found to be least stiff for static tests, almost the same as for the static case for prerotation drop tests as long as the tires remain rotating, and appreciably stiffer for drop tests without prerotation.

  5. Has Asthma Medication Use Caught Up With the Evidence?: A 12-Year Population-Based Study of Trends.

    PubMed

    Sadatsafavi, Mohsen; Tavakoli, Hamid; Lynd, Larry; FitzGerald, J Mark

    2017-03-01

    The importance of balance between controller and reliever medications in asthma is recognized. However, to our knowledge, the extent to which real-world practice has caught up with evidence-based guidelines has not been studied. This was a retrospective cohort study of individuals 15 to 67 years of age who satisfied a validated case definition of asthma in the administrative health database of British Columbia, Canada between 2002 and 2013. Each patient-year was assessed for inappropriate and excessive prescription of short-acting beta-agonists (SABAs) and the balance between controller and reliever medications. Trends on three time axes were evaluated: calendar time, time course of asthma, and age. Poisson regression was used to test for a linear trend. Three hundred fifty-six thousand, one hundred twelve patients (56.5% female sex; mean age, 30.5 years) contributed 2.6 million patient-years. In 7.3% of the patient-years, SABAs were prescribed inappropriately. This proportion dropped by a relative rate of 5.3% per year (P < .001). In the first year of asthma, 6.3% of patients had indicators of inappropriate SABA use, which dropped within the first 3 years but increased thereafter. Excessive prescription of SABAs increased rapidly during the time course of asthma (change of 23.3% per year; P < .001) and by age (change of 5.1% per year; P < .001). Despite overwhelming evidence regarding the risks, inappropriate prescription for SABAs was prevalent. Excessive SABA use might explain high asthma mortality in older patients. Inappropriate prescriptions declined over the study period but increased over the time course of asthma. These trends might have contributed to the declining asthma hospitalization rates in British Columbia, but there remain gaps in care and potential for improvement in asthma outcomes. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  6. Between-subject variability in asymmetry analysis of macular thickness.

    PubMed

    Alluwimi, Muhammed S; Swanson, William H; Malinovsky, Victor E

    2014-05-01

    To investigate the use of asymmetry analysis to reduce between-subject variability of macular thickness measurements using spectral domain optical coherence tomography. Sixty-three volunteers (33 young subjects [aged 21 to 35 years] and 30 older subjects [aged 45 to 85 years]) free of eye disease were recruited. Macular images were gathered with the Spectralis optical coherence tomography. An overlay 24- by 24-degree grid was divided into five zones per hemifield, and asymmetry analysis was computed as the difference between superior and inferior zone thicknesses. We hypothesized that the lowest variation and the highest density of ganglion cells will be found approximately 3 to 6 degrees from the foveola, corresponding to zones 1 and 2. For each zone and age group, between-subject SDs were compared for retinal thickness versus asymmetry analysis using an F test. To account for repeated comparisons, p < 0.0125 was required for statistical significance. Axial length and corneal curvature were measured with an IOLMaster. For OD, asymmetry analysis reduced between-subject variability in zones 1 and 2 in both groups (F > 3.2, p < 0.001). Standard deviation for zone 1 dropped from 12.0 to 3.0 μm in the young group and from 11.7 to 2.6 μm in the older group. Standard deviation for zone 2 dropped from 13.6 to 5.3 μm in the young group and from 11.1 to 5.8 μm in the older group. Combining all subjects, neither retinal thickness nor asymmetry analysis showed a strong correlation with axial length or corneal curvature (R² < 0.01). Analysis for OS yielded the same pattern of results, as did asymmetry analyses between eyes (F > 3.8, p < 0.0001). Asymmetry analysis reduced between-subject variability in zones 1 and 2. Combining the five zones together produced a higher between-subject variation of the retinal thickness asymmetry analysis; thus, we encourage clinicians to be cautious when interpreting the asymmetry analysis printouts.

  7. Pulmonary MRA: Differentiation of pulmonary embolism from truncation artifact

    PubMed Central

    Bannas, Peter; Schiebler, Mark L; Motosugi, Utaroh; François, Christopher J; Reeder, Scott B; Nagle, Scott K

    2015-01-01

    Purpose Truncation artifact (Gibbs ringing) causes central signal drop within vessels in pulmonary MRA that can be mistaken for emboli, reducing the diagnostic accuracy for pulmonary embolism (PE). We propose a quantitative approach to differentiate truncation artifact from PE. Methods Twenty-eight patients who underwent pulmonary CTA for suspected PE were recruited for pulmonary MRA. Signal intensity drops within pulmonary arteries that persisted on both arterial-phase and delayed-phase MRA were identified. The percent signal loss between the vessel lumen and central drop was measured. CTA served as the reference standard for presence of pulmonary emboli. Results A total of 65 signal intensity drops were identified on MRA. 48 (74%) of these were artifact and 17 (26%) were PE, as confirmed by CTA. Truncation artifacts had a significantly lower median signal drop than PE at both arterial-phase (26% [range 12–58%] vs. 85% [range 53–91%]) and at delayed-phase MRA (26% [range 11–55%] vs. 77% [range 47–89%]), p<0.0001 for both. ROC analyses revealed a threshold value of 51% (arterial-phase) and 47%-signal drop (delayed-phase) to differentiate between truncation artifact and PE with 100% sensitivity and >90% specificity. Conclusion Quantitative signal drop is an objective tool to help differentiate truncation artifact and pulmonary embolism in pulmonary MRA. PMID:24863886

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lillo, Thomas Martin

    During the first quarter of FY17, research has focused on: 1. Generation of synthetic microstructures of welds 2. Aging of gamma prime 3. Short term creep tests 4. Preparation for stress drop tests to determine the threshold stress.

  9. Drop Testing Representative Multi-Canister Overpacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, Spencer D.; Morton, Dana K.

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capablemore » of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10 -5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10 -7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.« less

  10. Instrumentation and telemetry systems for free-flight drop model testing

    NASA Technical Reports Server (NTRS)

    Hyde, Charles R.; Massie, Jeffrey J.

    1993-01-01

    This paper presents instrumentation and telemetry system techniques used in free-flight research drop model testing at the NASA Langley Research Center. The free-flight drop model test technique is used to conduct flight dynamics research of high performance aircraft using dynamically scaled models. The free-flight drop model flight testing supplements research using computer analysis and wind tunnel testing. The drop models are scaled to approximately 20 percent of the size of the actual aircraft. This paper presents an introduction to the Free-Flight Drop Model Program which is followed by a description of the current instrumentation and telemetry systems used at the NASA Langley Research Center, Plum Tree Test Site. The paper describes three telemetry downlinks used to acquire the data, video, and radar tracking information from the model. Also described are two telemetry uplinks, one used to fly the model employing a ground-based flight control computer and a second to activate commands for visual tracking and parachute recovery of the model. The paper concludes with a discussion of free-flight drop model instrumentation and telemetry system development currently in progress for future drop model projects at the NASA Langley Research Center.

  11. The Ability of an Aftermarket Helmet Add-On Device to Reduce Impact-Force Accelerations During Drop Tests.

    PubMed

    Breedlove, Katherine M; Breedlove, Evan; Nauman, Eric; Bowman, Thomas G; Lininger, Monica R

    2017-09-01

      The Guardian Cap provides a soft covering intended to mitigate energy transfer to the head during football contact. Yet how well it attenuates impacts remains unknown.   To evaluate the changes in the Gadd Severity Index (GSI) and linear acceleration during drop tests on helmeted headforms with or without Guardian Caps.   Crossover study.   Laboratory.   Nine new football helmets sent directly from the manufacturer.   We dropped the helmets at 3 velocities on 6 helmet locations (front, side, right front boss, top, rear right boss, and rear) as prescribed by the National Operating Committee on Standards for Athletic Equipment. Helmets were tested with facemasks in place but no Guardian Cap and then retested with the facemasks in place and the Guardian Cap affixed.   The GSI scores and linear accelerations measured in g forces.   For the GSI, we found a significant interaction among drop location, Guardian Cap presence, and helmet brand at the high velocity (F 10,50 = 3.01, P = .005) but not at the low (F 3.23,16.15 = 0.84, P = .50) or medium (F 10,50 = 1.29, P = .26) velocities. Similarly for linear accelerations, we found a significant interaction among drop location, Guardian Cap presence, and helmet brand at the high velocity (F 10,50 = 3.01, P = .002, ω 2 = 0.05) but not at the low (F 10,50 = 0.49, P = .89, ω 2 < 0.01, 1-β = 0.16) or medium (F 5.20,26.01 = 2.43, P = .06, ω 2 < 0.01, 1-β = 0.68) velocities.   The Guardian Cap failed to significantly improve the helmets' ability to mitigate impact forces at most locations. Limited evidence indicates how a reduction in GSI would provide clinically relevant benefits beyond reducing the risk of skull fracture or a similar catastrophic event.

  12. Comparative Analysis of THOR-NT ATD vs. Hybrid III ATD in Laboratory Vertical Shock Testing

    DTIC Science & Technology

    2013-09-01

    were taken both pretest and post - test for each test event (figure 5). Figure 5. Rigid fixture placed on the drop table with ATD seated: Hybrid III...6 3. Experimental Procedure 6 3.1 Test Setup...frames per second and with a Vision Research Phantom V9.1 (Wayne, NJ) high-speed video camera, sampling 1000 frames per second. 3. Experimental

  13. 40 CFR Table 3 to Subpart Jjjjjj... - Operating Limits for Boilers With Emission Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system alarm does not sound more than 5 percent of the operating time during each 6-month period. 2... the pressure drop at or above the lowest 1-hour average pressure drop across the wet scrubber and the... recent performance stack test. 8. Continuous Oxygen Monitor Maintain the oxygen level at or above the...

  14. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... temperature and pressure sensors, outdoor enclosure, electrical power supply, control devices and operator... rate cut-off; operation following power interruptions; effect of variations in power line voltage... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted...

  15. Experimental investigation of ice slurry flow pressure drop in horizontal tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grozdek, Marino; Khodabandeh, Rahmatollah; Lundqvist, Per

    2009-01-15

    Pressure drop behaviour of ice slurry based on ethanol-water mixture in circular horizontal tubes has been experimentally investigated. The secondary fluid was prepared by mixing ethyl alcohol and water to obtain initial alcohol concentration of 10.3% (initial freezing temperature -4.4 C). The pressure drop tests were conducted to cover laminar and slightly turbulent flow with ice mass fraction varying from 0% to 30% depending on test conditions. Results from flow tests reveal much higher pressure drop for higher ice concentrations and higher velocities in comparison to the single phase flow. However for ice concentrations of 15% and higher, certain velocitymore » exists at which ice slurry pressure drop is same or even lower than for single phase flow. It seems that higher ice concentration delay flow pattern transition moment (from laminar to turbulent) toward higher velocities. In addition experimental results for pressure drop were compared to the analytical results, based on Poiseulle and Buckingham-Reiner models for laminar flow, Blasius, Darby and Melson, Dodge and Metzner, Steffe and Tomita for turbulent region and general correlation of Kitanovski which is valid for both flow regimes. For laminar flow and low buoyancy numbers Buckingham-Reiner method gives good agreement with experimental results while for turbulent flow best fit is provided with Dodge-Metzner and Tomita methods. Furthermore, for transport purposes it has been shown that ice mass fraction of 20% offers best ratio of ice slurry transport capability and required pumping power. (author)« less

  16. 49 CFR 173.57 - Acceptance criteria for new explosives.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... must be subjected to the Drop Weight Impact Sensitivity Test (Test Method 3(a)(i)), the Friction... substance has a friction sensitiveness equal to or greater than that of dry pentaerythrite tetranitrate (PETN) when tested in the Friction Sensitivity Test; (4) The substance fails to pass the test criteria...

  17. High Temperature Test Facility Preliminary RELAP5-3D Input Model Description

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bayless, Paul David

    A RELAP5-3D input model is being developed for the High Temperature Test Facility at Oregon State University. The current model is described in detail. Further refinements will be made to the model as final as-built drawings are released and when system characterization data are available for benchmarking the input model.

  18. Drop-on-demand drop formation of polyethylene oxide solutions

    NASA Astrophysics Data System (ADS)

    Yan, Xuejia; Carr, Wallace W.; Dong, Hongming

    2011-10-01

    The dynamics of drop-on-demand (DOD) drop formation for solutions containing polyethylene oxide (PEO) have been studied experimentally. Using a piezoelectrical actuated inkjet printhead with the nozzle orifice diameter of 53 μm, experiments were conducted for a series of PEO aqueous solutions with molecular weights ranging from 14 to 1000 kg/mol, polydispersity from 1.02 to 2.5, and concentrations from 0.005 to 10 wt. %. The addition of a small amount of PEO can have a significant effect on the DOD drop formation process, increasing breakup time, decreasing primary drop speed, and decreasing the number of satellite drops in some cases. The effects depend on both molecular weight and concentration. At lower molecular weights (14 and 35 kg/mol), the effect of PEO over the dilute solution regime is insignificant even at concentrations large enough that the solution does not fall in the dilute regime. As PEO molecular weight increased, the effects became significant. For monodispersed PEO solutions, breakup time and primary drop speed closely correlated with effective relaxation time but not for polydispersed PEO. Effective relaxation time depended greatly on molecular weight distribution. Viscosity-average molecular weight, used in calculating effective relaxation time for polydispersed PEO solutions, did not adequately account for high molecular fractions in the molecular weight distribution of the polydispersed PEOs. A mixture rule was developed to calculate the effective relaxation times for aqueous solutions containing mixtures of monodispersed PEO, and breakup times and primary drop speeds correlated well with effective relaxation times. For our experiments, DOD drop formation was limited to Deborah number ≲ 23.

  19. 30 CFR 7.67 - Construction test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 7.66. (a) Test procedures. (1) The blasting unit shall be dropped 20 times from a height of 3 feet... each time in an attempt to have a different surface, corner, or edge strike the floor first for each... shall be submerged in 1 foot of water for 1 hour in each of 3 tests. The water temperature shall be...

  20. The effect of dropping height on jumping performance in trained and untrained prepubertal boys and girls.

    PubMed

    Bassa, Eleni I; Patikas, Dimitrios A; Panagiotidou, Aikaterini I; Papadopoulou, Sophia D; Pylianidis, Theofilos C; Kotzamanidis, Christos M

    2012-08-01

    Plyometric training in children, including different types of jumps, has become common practice during the last few years in different sports, although there is limited information about the adaptability of children with respect to different loads and the differences in performance between various jump types. The purpose of this study was to examine the effect of gender and training background on the optimal drop jump height of 9- to 11-year-old children. Sixty prepubertal (untrained and track and field athletes, boys and girls, equally distributed in each group [n = 15]), performed the following in random order: 3 squat jumps, 3 countermovement jumps (CMJs) and 3 drop jumps from heights of 10, 20, 30, 40, and 50 cm. The trial with the best performance in jump height of each test was used for further analysis. The jump type significantly affected the jump height. The jump height during the CMJ was the highest among all other jump types, resulting in advanced performance for both trained and untrained prepubertal boys and girls. However, increasing the dropping height did not change the jumping height or contact time during the drop jump. This possibly indicates an inability of prepubertal children to use their stored elastic energy to increase jumping height during drop jumps, irrespective of their gender or training status. This indicates that children, independent of gender and training status, have no performance gain during drop jumps from heights up to 50 cm, and therefore, it is recommended that only low drop jump heights be included in plyometric training to limit the probability of sustaining injuries.

  1. Effect of soil moisture content on the splash phenomenon reproducibility.

    PubMed

    Ryżak, Magdalena; Bieganowski, Andrzej; Polakowski, Cezary

    2015-01-01

    One of the methods for testing splash (the first phase of water erosion) may be an analysis of photos taken using so-called high-speed cameras. The aim of this study was to determine the reproducibility of measurements using a single drop splash of simulated precipitation. The height from which the drops fell resulted in a splash of 1.5 m. Tests were carried out using two types of soil: Eutric Cambisol (loamy silt) and Orthic Luvisol (sandy loam); three initial pressure heads were applied equal to 16 kPa, 3.1 kPa, and 0.1 kPa. Images for one, five, and 10 drops were recorded at a rate of 2000 frames per second. It was found that (i) the dispersion of soil caused by the striking of the 1st drop was significantly different from the splash impact caused by subsequent drops; (ii) with every drop, the splash phenomenon proceeded more reproducibly, that is, the number of particles of soil and/or water that splashed were increasingly close to each other; (iii) the number of particles that were detached during the splash were strongly correlated with its surface area; and (iv) the higher the water film was on the surface the smaller the width of the crown was.

  2. Effect of Soil Moisture Content on the Splash Phenomenon Reproducibility

    PubMed Central

    Ryżak, Magdalena; Bieganowski, Andrzej; Polakowski, Cezary

    2015-01-01

    One of the methods for testing splash (the first phase of water erosion) may be an analysis of photos taken using so-called high-speed cameras. The aim of this study was to determine the reproducibility of measurements using a single drop splash of simulated precipitation. The height from which the drops fell resulted in a splash of 1.5 m. Tests were carried out using two types of soil: Eutric Cambisol (loamy silt) and Orthic Luvisol (sandy loam); three initial pressure heads were applied equal to 16 kPa, 3.1 kPa, and 0.1 kPa. Images for one, five, and 10 drops were recorded at a rate of 2000 frames per second. It was found that (i) the dispersion of soil caused by the striking of the 1st drop was significantly different from the splash impact caused by subsequent drops; (ii) with every drop, the splash phenomenon proceeded more reproducibly, that is, the number of particles of soil and/or water that splashed were increasingly close to each other; (iii) the number of particles that were detached during the splash were strongly correlated with its surface area; and (iv) the higher the water film was on the surface the smaller the width of the crown was. PMID:25785859

  3. Bilateral contact ground reaction forces and contact times during plyometric drop jumping.

    PubMed

    Ball, Nick B; Stock, Christopher G; Scurr, Joanna C

    2010-10-01

    Drop jumping (DJ) is used in training programs aimed to improve lower extremity explosive power. When performing double-leg drop jumps, it is important to provide an equal stimulus to both legs to ensure balanced development of the lower legs. The aim of this study was to bilaterally analyze the ground reactions forces and temporal components of drop jumping from 3 heights. Ten recreationally active male subjects completed 3 bounce-drop jumps from 3 starting heights (0.2, 0.4, and 0.6 m). Two linked force platforms were used to record left- and right-leg peak vertical force, time to peak force, average force, ground contact time, impulse and time differential. Between-height and between-leg comparisons for each variable were made using a multivariate analysis of variance with post hoc Wilcoxon tests (p < 0.05). Results indicated that force and time variables increased as drop jump height increased (p < 0.0001). Post hoc analyses showed that at 0.2- and 0.4-m bilateral differences were present in the time to peak force, average force, and impulse. No bilateral differences for any variables were shown at 0.6-m starting height. The contact time for all jumps was <0.26 seconds. At 0.2 m, only 63% of the subjects had a starting time differential of <0.01 seconds, rising to 96.3% at 0.6 m. The results indicated that 0.6 m is the suggested drop jump height to ensure that no bilateral differences in vertical forces and temporal components occur; however, shorter contact times were found at the lower heights.

  4. Effect of prophylactic antibiotic drops on ocular microbiota and physiology during silicone hydrogel lens wear.

    PubMed

    Ozkan, Jerome; Zhu, Hua; Gabriel, Manal; Holden, Brien A; Willcox, Mark D P

    2012-03-01

    Bacterial contamination of the contact lens surface has been demonstrated to cause corneal infiltrative events. A reduction in the rate of bacterially driven corneal infiltrative events associated with lens wear is one of the major goals of the contact lens industry. There is a concern over the potential of any antimicrobial strategy that there will be unwanted changes to the ocular microbiota or the development of resistance to the antimicrobial. The aim of this study was to investigate the effect of prophylactic topical antibiotic instillation during continuous wear of silicone hydrogel lenses on the normal ocular microbiota, the throat microbiota, and the ocular physiology. Forty-two male subjects were dispensed with lotrafilcon A silicone hydrogel contact lenses for a 3-month, 30 night continuous wear, monthly replacement trial. Subjects were randomized into either tobramycin 0.3% (test) or saline (control) drop group. Two drops were instilled into each eye on waking and before sleep. At monthly visits, lenses were collected aseptically, and ocular and throat swabs were performed, followed by standard microbial recovery and identifications. Any corneal infiltrative event at scheduled or unscheduled visits was recorded. Numbers of microbes recovered from eye swabs from the tobramycin (test) group were significantly lower than the control (p = 0.01). Gram-positive cocci were recovered less frequently from the test group (p = 0.001). There were no significant differences in the numbers and types of microbes recovered from lens samples, or the contamination rate of the lenses between the two groups. There were no changes in the numbers of fungi or bacteria from throat swabs. There was no evidence of changes to resistance profile of microbes in the throat. More eye swabs from the test group (68.5%) were culture-negative than swabs from control (46.5%; p = 0.002). The test group had less corneal staining superiorly (0.0 ± 0.0 vs. 0.3 ± 0.4; p = 0.025) but increased bulbar redness (2.2 ± 0.5 vs. 1.5 ± 0.4; p < 0.001) at the 3-month visit only, compared with control group. Overall, there appeared to be a minimal safety risk with 3-month's prophylactic antibiotic drop use during continuous wear of silicone hydrogel lenses. Clinically, antibiotic drop use induced a mild to moderate increase in bulbar redness by the 3-month time-point. Antibiotic use reduced microbiota on lids but did not affect the microbiota of the throat or change resistance to tobramycin.

  5. Implementation of an axisymmetric drop shape apparatus using a Raspberry-Pi single-board computer and a web camera

    NASA Astrophysics Data System (ADS)

    Carlà, Marcello; Orlando, Antonio

    2018-07-01

    This paper describes the implementation of an axisymmetric drop shape apparatus for the measurement of surface or interfacial tension of a hanging liquid drop, using only cheap resources like a common web camera and a single-board microcomputer. The mechanics of the apparatus is composed of stubs of commonly available aluminium bar, with all other mechanical parts manufactured with an amateur 3D printer. All of the required software, either for handling the camera and taking the images, or for processing the drop images to get the drop profile and fit it with the Bashforth and Adams equation, is freely available under an open source license. Despite the very limited cost of the whole setup, an extensive test has demonstrated an overall accuracy of ±0.2% or better.

  6. Free Radical Scavenging Activity of Drops and Spray Containing Propolis-An EPR Examination.

    PubMed

    Olczyk, Pawel; Komosinska-Vassev, Katarzyna; Ramos, Pawel; Mencner, Lukasz; Olczyk, Krystyna; Pilawa, Barbara

    2017-01-13

    The influence of heating at a temperature of 50 °C and UV-irradiation of propolis drops and spray on their free radical scavenging activity was determined. The kinetics of interactions of the propolis samples with DPPH free radicals was analyzed. Interactions of propolis drops and propolis spray with free radicals were examined by electron paramagnetic resonance spectroscopy. A spectrometer generating microwaves of 9.3 GHz frequency was used. The EPR spectra of the model DPPH free radicals were compared with the EPR spectra of DPPH in contact with the tested propolis samples. The antioxidative activity of propolis drops and propolis spray decreased after heating at the temperature of 50 °C. A UV-irradiated sample of propolis drops more weakly scavenged free radicals than an untreated sample. The antioxidative activity of propolis spray increased after UV-irradiation. The sample of propolis drops heated at the temperature of 50 °C quenched free radicals faster than the unheated sample. UV-irradiation weakly changed the kinetics of propolis drops or spray interactions with free radicals. EPR analysis indicated that propolis drops and spray should not be stored at a temperature of 50 °C. Propolis drops should not be exposed to UV-irradiation.

  7. An experimental design for total container impact response modeling at extreme temperatures

    NASA Technical Reports Server (NTRS)

    Kobler, V. P.; Wyskida, R. M.; Johannes, J. D.

    1979-01-01

    An experimental design (a drop test) was developed to test the effects of confinement upon cushions. The drop test produced consistent corner void cushion data from which mathematical models were developed. A mathematical relationship between temperature and drop height was found.

  8. High Incidence of Preharvest Colonization of Huanglongbing-Symptomatic Citrus sinensis Fruit by Lasiodiplodia theobromae (Diplodia natalensis) and Exacerbation of Postharvest Fruit Decay by That Fungus

    PubMed Central

    Zhao, Wei; Bai, Jinhe; McCollum, Greg

    2014-01-01

    Huanglongbing (HLB), presumably caused by the bacterium “Candidatus Liberibacter asiaticus,” is a devastating citrus disease associated with excessive preharvest fruit drop. Lasiodiplodia theobromae (diplodia) is the causal organism of citrus stem end rot (SER). The pathogen infects citrus fruit under the calyx abscission zone (AZ-C) and is associated with cell wall hydrolytic enzymes similar to plant enzymes involved in abscission. By means of DNA sequencing, diplodia was found in “Ca. Liberibacter asiaticus”-positive juice from HLB-symptomatic fruit (S) but not in “Ca. Liberibacter asiaticus”-negative juice. Therefore, the incidence of diplodia in fruit tissues, the impact on HLB-related postharvest decay, and the implications for HLB-related preharvest fruit drop were investigated in Hamlin and Valencia oranges. Quantitative PCR results (qPCR) revealed a significantly (P < 0.001) greater incidence of diplodia in the AZ-C of HLB-symptomatic (S; “Ca. Liberibacter asiaticus” threshold cycle [CT] of <30) than in the AZ-C of in asymptomatic (AS; “Ca. Liberibacter asiaticus” CT of ≥30) fruit. In agreement with the qPCR results, 2 weeks after exposure to ethylene, the incidences of SER in S fruit were 66.7% (Hamlin) and 58.7% (Valencia), whereas for AS fruit the decay rates were 6.7% (Hamlin) and 5.3% (Valencia). Diplodia colonization of S fruit AZ-C was observed by scanning electron microscopy and confirmed by PCR test and morphology of conidia in isolates from the AZ-C after surface sterilization. Diplodia CT values were negatively correlated with ethylene production (R = −0.838 for Hamlin; R = −0.858 for Valencia) in S fruit, and positively correlated with fruit detachment force (R = 0.855 for Hamlin; R = 0.850 for Valencia), suggesting that diplodia colonization in AZ-C may exacerbate HLB-associated preharvest fruit drop. PMID:25344245

  9. Effects of Evaporation/Condensation on Spreading and Contact Angle of a Volatile Liquid Drop

    NASA Technical Reports Server (NTRS)

    Zhang, Nengli; Chao, David F.; Singh, Bhim S. (Technical Monitor)

    2000-01-01

    Effects of evaporation/condensation on spreading and contact angle were experimentally studied. A sessile drop of R-113 was tested at different vapor environments to determine the effects of evaporation/condensation on the evolution of contact diameter and contact angle of the drop. Condensation on the drop surface occurs at both the saturated and a nonsaturated vapor environments and promotes the spreading. When the drop is placed in the saturated vapor environment it tends to completely wetting and spreads rapidly. In a nonsaturated vapor environment, the evolution of the sessile drop is divided three stages: condensation-spreading stage, evaporation-retracting stage and rapid contracting stage. In the first stage the drop behaves as in the saturated environment. In the evaporation -retracting stage, the competition between spreading and evaporation of the drop determines the evolution characteristics of the contact diameter and the contact angle. A lower evaporation rate struggles against the spreading power to turn the drop from spreading to retracting with a continuous increase of the contact angle. The drop placed in open air has a much higher evaporation rate. The strong evaporation suppresses the spreading and accelerates the retraction of the drop with a linear decrease of the contact diameter. The contraction of the evaporating drops is gradually accelerated when the contact diameter decreases to 3 min and less till drying up, though the evaporation rate is gradually slowing down.

  10. An assessment of RELAP5-3D using the Edwards-O'Brien Blowdown problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomlinson, E.T.; Aumiller, D.L.

    1999-07-01

    The RELAP5-3D (version bt) computer code was used to assess the United States Nuclear Regulatory Commission's Standard Problem 1 (Edwards-O'Brien Blowdown Test). The RELAP5-3D standard installation problem based on the Edwards-O'Brien Blowdown Test was modified to model the appropriate initial conditions and to represent the proper location of the instruments present in the experiment. The results obtained using the modified model are significantly different from the original calculation indicating the need to model accurately the experimental conditions if an accurate assessment of the calculational model is to be obtained.

  11. Test-Analysis Correlation of a Crash Simulation of a Vertical Drop Test of a Commuter-Category Aircraft

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.

    2004-01-01

    A finite element model of an ATR42-300 commuter-class aircraft was developed and a crash simulation was executed. Analytical predictions were correlated with data obtained from a 30-feet per second (9.14-meters per second) vertical drop test of the aircraft. The purpose of the test was to evaluate the structural response of the aircraft when subjected to a severe, but survivable, impact. The aircraft was configured with seats, dummies, luggage, and other ballast. The wings were filled with 8,700 lb. (3,946 kilograms) of water to represent the fuel. The finite element model, which consisted of 57,643 nodes and 62,979 elements, was developed from direct measurements of the airframe geometry. The seats, dummies, luggage, simulated engines and fuel, and other ballast were represented using concentrated masses. The model was executed in LS-DYNA, a commercial finite element code for performing explicit transient dynamic simulations. Analytical predictions of structural deformation and selected time-history responses were correlated with experimental data from the drop test to validate the simulation.

  12. A clinical study on "Computer vision syndrome" and its management with Triphala eye drops and Saptamrita Lauha.

    PubMed

    Gangamma, M P; Poonam; Rajagopala, Manjusha

    2010-04-01

    American Optometric Association (AOA) defines computer vision syndrome (CVS) as "Complex of eye and vision problems related to near work, which are experienced during or related to computer use". Most studies indicate that Video Display Terminal (VDT) operators report more eye related problems than non-VDT office workers. The causes for the inefficiencies and the visual symptoms are a combination of individual visual problems and poor office ergonomics. In this clinical study on "CVS", 151 patients were registered, out of whom 141 completed the treatment. In Group A, 45 patients had been prescribed Triphala eye drops; in Group B, 53 patients had been prescribed the Triphala eye drops and SaptamritaLauha tablets internally, and in Group C, 43 patients had been prescribed the placebo eye drops and placebo tablets. In total, marked improvement was observed in 48.89, 54.71 and 06.98% patients in groups A, B and C, respectively.

  13. 49 CFR 178.603 - Drop test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... aluminum boxes, Composite packagings which are in the shape of a box Five—(one for each drop) First drop... impact. Where more than one orientation is possible for a given drop test, the orientation most likely to... example a closure or, for some 7 cylindrical drums, the welded longitudinal seam of the drum body. Boxes...

  14. Response of Metals and Metallic Structures to Dynamic Loading

    DTIC Science & Technology

    1978-05-01

    materials for service by testing under high rates of loading. Impact tests such as the Charpy test, the drop-weight tear test, and the dynamic tear...have clearly shown this for precracked charpy specimens and for the drop-weight tear test. Hence, there is a strong need for additional dynamic...dynamic fracture resistance ( Charpy , dynamic-tear, drop-weight tear test, etc.), normally assures that fracture in dynamically loaded structures is

  15. A Moment Rate Function Deduced from Peak Ground Motions from M 3.3-5.3 Earthquakes: Implications for Scaling, Corner Frequency and Stress Drop

    NASA Astrophysics Data System (ADS)

    Archuleta, R. J.; Ji, C.

    2016-12-01

    Based on 3827 records of peak horizontal ground motions in the NGA-West2 database we computed linear regressions for Log PGA, Log PGV and the ratio PGA/2πPGV (which we call dominant frequency, DomF) versus moment magnitude for M 3.3-5.3 earthquakes. The slopes are nearly one for Log PGA and Log PGV and negative one for PGA/PGV. For magnitudes 5.3 and smaller the source can be treated as a point source. Using these regressions and an expression between the half peak-to-peak amplitude of Wood Anderson records (PWA) and moment magnitude, we have deduced an `apparent' moment rate function (aMRF) that increases quadratically in time until it reaches its maximum at time tp after which it decays linearly until a final duration td. For t*=0.054 s and with parameters tp and td scaling with seismic moment, tp(M0) = 0.03[M0/ M0(M=3.3)]1/7.0 and td(M0) = 0.31[M0/ M0(M=3.3)]1/3.3 . all the magnitude dependence within M 3.3-5.3 can be explained. The Fourier amplitude spectrum (FAS) of the aMRF has two corner frequencies connected by an intermediate slope of f-1. The smaller corner frequency fC 1/ td, i.e., a corner frequency related to the full duration. Stress drop associated with the average over the fault scales weakly with seismic moment Δσ M00.09. The larger corner frequency is proportional to 1/ tp. We also find that DomF ≈ 1/[2.2(tp(M0) + t*)], thus there is a strong tradeoff between tp and t*. The higher corner frequency and the intermediate slope in the spectrum could be completely obscured by t* for t* 0.04-0.06 s, producing a Brune-type spectrum. If so, it will be practically impossible to retrieve the true spectrum. Because the fC derived from the spectrum is controlled by td while PGA and PGV are controlled mostly by the time scale tp, this aMRF could explain the difference in uncertainty of the mean stress drop inferred from peak ground motion data and that inferred from displacement amplitude spectra. This aMRF is consistent with a rupture that initiates from a critical crack length, e.g., Campillo and Ionescu (1997), Ohnaka (2000). In such a scenario, the peak time corresponds to rupture of the critical crack length with a stress change corresponding to breakdown stress, not stress drop. This is consistent with a stress parameter for predicting ground motion larger than the stress drop generally found by spectral studies.

  16. Evaluation of wheelchair drop seat crashworthiness.

    PubMed

    Bertocci, G; Ha, D; van Roosmalen, L; Karg, P; Deemer, E

    2001-05-01

    Wheelchair seating crash performance is critical to protecting wheelchair users who remain seated in their wheelchairs during transportation. Relying upon computer simulation and sled testing seat loads associated with a 20 g/48 kph (20 g/30 mph) frontal impact and 50th percentile male occupant were estimated to develop test criteria. Using a static test setup we evaluated the performance of various types of commercially available drop seats against the loading test criteria. Five different types of drop seats (two specimens each) constructed of various materials (i.e. plastics, plywood, metal) were evaluated. Two types of drop seats (three of the total 10 specimens) met the 16650 N (3750 lb) frontal impact test criteria. While additional validation of the test protocol is necessary, this study suggests that some drop seat designs may be incapable of withstanding crash level loads.

  17. Systems Training for Emotional Predictability and Problem Solving (STEPPS): program efficacy and personality features as predictors of drop-out -- an Italian study.

    PubMed

    Alesiani, Roberta; Boccalon, Silvia; Giarolli, Laura; Blum, Nancee; Fossati, Andrea

    2014-05-01

    In this study we present a clinical application of the STEPPS model in an Italian sample of severely affected patients with borderline personality disorder (BPD) or personality disorder (PD) with prominent borderline features in comorbidity with a mood disorder. The aims of this work are: 1) to confirm our preliminary results in a larger sample and at a 12-month follow-up, and 2) to identify predictors of drop-out vs completion of STEPPS in order to understand which characteristics of patients make them suitable or not for this treatment. The sample is composed of 32 subjects recruited from a population of inpatients of the Mood Disorders Center, Department of Clinical Neurosciences, Hospital San Raffaele-Turro, Milan. To confirm STEPPS efficacy at 12-month follow-up, we selected the following outcome criteria: reduction in the number of hospitalizations related to self-harm acts; reduction in the number of suicidal attempts; reduction of perceived emotional intensity levels; changes in cognitive filter scores; changes in the scores on self-report questionnaires. To identify predictors of drop-out vs completion, we analysed the following variables: demographic features (sex, marital status, school level achieved, and job status); Axis-I diagnosis; Axis-II categorical and dimensional diagnosis; and personality features. Seventeen (53%) subjects completed the treatment successfully. The drop-out rate was 47%. Patients who completed the program show a significant decrease in the number of hospitalizations, both at the end of the treatment and at 12-month follow-up. Friedman ANOVA test shows a significant decrease in suicidal attempts during and after STEPPS, and at 12-month follow-up. Analysis of drop-outs showed no significant differences with regard to sex, marital status, school level and job status between the two groups. Axis-I and Axis-II categorical diagnoses did not discriminate between the two groups. Those patients who dropped differ significantly from completers in histrionic personality traits and magical thinking index, given by the interaction between low scores in Self-Directedness and high scores in Self-Transcendence. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Antimicrobial and Herbal Drug Resistance in Enteric Bacteria Isolated from Faecal Droppings of Common House Lizard/Gecko (Hemidactylus frenatus).

    PubMed

    Singh, Bhoj R; Singh, Vidya; Ebibeni, N; Singh, Raj K

    2013-01-01

    From 194 faecal dropping samples of common house geckos collected from offices (60), houses (88), integrated farm units (IFS,18) and hostels, guest houses, and dining rooms of different canteen/mess (HGM, 28), 326 bacterial isolates of enteric bacteria belonging to 17 genera and 34 species were detected. Escherichia coli were the most frequently (39) isolated followed by Citrobacter freundii (33), Klebsiella pneumonia (27), Salmonella indica (12), Enterobacter gergoviae (12), and Ent. agglomerans (11). Other important bacteria isolated from gecko droppings were Listonella damsela (2), Raoultella terrigena (3), S. salamae (2), S. houtenae (3), Edwardsiella tarda (4), Edwardsiella hoshinae (1), and Klebsiella oxytoca (2). Of the 223 isolates tested for antimicrobial drug sensitivity, 27 (12.1%) had multiple drug resistance (MDR). None of the salmonellae or edwardsiellae had MDR however, MDR strains were significantly more common among Escherichia spp. (P = 1.9 × 10(-5)) and isolates from IFS units (P = 3.58 × 10(-23)). The most effective herbal drug, Ageratum conyzoides extract, inhibited growth of only 27.8% of strains tested followed by ethanolic extract of Zanthoxylum rhetsa (13.9%), eucalyptus oil (5.4%), patchouli oil (5.4%), lemongrass oil (3.6%), and sandalwood oil (3.1%), and Artemisia vulgaris essential oil (3.1%).

  19. Kinematic And Neuromuscular Measures Of Intensity During Plyometric Jumps.

    PubMed

    Andrade, David Cristóbal; Manzo, Oscar; Beltrán, Ana Rosa; Álvarez, Cristian; Del Rio, Rodrigo; Toledo, Camilo; Moran, Jason; Ramirez-Campillo, Rodrigo

    2017-08-15

    The aim of this study was to assess jumping performance and neuromuscular activity in lower limb muscles after drop jumps (DJ) from different drop heights (intensity) and during continuous jumping (fatigue), using markers such as reactive strength, jump height, mechanical power and surface electromyography (sEMG). The eccentric (EC) and concentric (CON) sEMG from the medial gastrocnemius (MG), biceps femoris (BF) and rectus (R) muscles were assessed during all tests. In a cross-sectional, randomized study, eleven volleyball players (age 24.4±3.2 years) completed 20 to 90-cm (DJ20 to DJ90) drop jumps and a 60-s continuous jump test. A one-way ANOVA test was used for comparisons, with Sidak post-hoc. The α level was <0.05. Reactive strength was greater for DJ40 compared to DJ90 (p<0.05; ES: 1.27). Additionally jump height was greater for DJ40 and DJ60 compared to DJ20 (p<0.05; ES: 1.26 and 1.27, respectively). No clear pattern of neuromuscular activity appeared during DJ20 to DJ90: some muscles showed greater, lower, or no change with increasing heights for both agonist and antagonist muscles, as well as for eccentric and concentric activity. Mechanical power, but not reactive strength, was reduced in the 60-s jump test (p<0.05; ES: 3.46). No changes were observed in sEMG for any muscle during the eccentric phase nor for the R muscle during the concentric phase of the 60-s jump test. However, for both MG and BF, concentric sEMG was reduced during the 60-s jump test (p<0.05; ES: 5.10 and 4.61, respectively). In conclusion, jumping performance and neuromuscular markers are sensitive to DJ height (intensity), although not in a clear dose-response fashion. In addition, markers such as mechanical power and sEMG are especially sensitive to the effects of continuous jumping (fatigue). Therefore, increasing the drop height during DJ does not ensure a greater training intensity and a combination of different drop heights may be required to elicit adaptations.

  20. Piezoelectric Response of Ferroelectric Ceramics Under Mechanical Stress

    DTIC Science & Technology

    2015-09-17

    dynamic response, and predict mechanical breakdown of electronic materials, numerous testing techniques such as very high-g machines , drop towers...James C. Hierholzer for building the custom test fixture, Michael D. Craft for his help with static capacitance measurements, Bryan J. Turner, Scott D...ISOLA 370HR Board Specimen Test Set-Up . . . . . . . . . . . . . . . . . . 59 3.3 Printed Circuit Board Electrical Layout

  1. Pulmonary MRA: differentiation of pulmonary embolism from truncation artefact.

    PubMed

    Bannas, Peter; Schiebler, Mark L; Motosugi, Utaroh; François, Christopher J; Reeder, Scott B; Nagle, Scott K

    2014-08-01

    Truncation artefact (Gibbs ringing) causes central signal drop within vessels in pulmonary magnetic resonance angiography (MRA) that can be mistaken for emboli, reducing diagnostic accuracy for pulmonary embolism (PE). We propose a quantitative approach to differentiate truncation artefact from PE. Twenty-eight patients who underwent pulmonary computed tomography angiography (CTA) for suspected PE were recruited for pulmonary MRA. Signal intensity drops within pulmonary arteries that persisted on both arterial-phase and delayed-phase MRA were identified. The percent signal loss between the vessel lumen and central drop was measured. CTA served as the reference standard for presence of pulmonary emboli. A total of 65 signal intensity drops were identified on MRA. Of these, 48 (74%) were artefacts and 17 (26%) were PE, as confirmed by CTA. Truncation artefacts had a significantly lower median signal drop than PE on both arterial-phase (26% [range 12-58%] vs. 85% [range 53-91%]) and delayed-phase MRA (26% [range 11-55%] vs. 77% [range 47-89%]), p < 0.0001 for both. Receiver operating characteristic (ROC) analyses revealed a threshold value of 51% (arterial phase) and 47% signal drop (delayed phase) to differentiate between truncation artefact and PE with 100% sensitivity and greater than 90% specificity. Quantitative signal drop is an objective tool to help differentiate truncation artefact and pulmonary embolism in pulmonary MRA. • Inexperienced readers may mistake truncation artefacts for emboli on pulmonary MRA • Pulmonary emboli have non-uniform signal drop • 51% (arterial phase) and 47% (delayed phase) cut-off differentiates truncation artefact from PE • Quantitative signal drop measurement enables more accurate pulmonary embolism diagnosis with MRA.

  2. 49 CFR 572.102 - Drop test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... surface when the midsagittal plane is vertical. (4) Drop the headform from the specified height by means... test. (a) When the headform is dropped from a height of 14.8 inches in accordance with paragraph (b) of...

  3. Multi-Terrain Vertical Drop Tests of a Composite Fuselage Section

    NASA Technical Reports Server (NTRS)

    Kellas, Sotiris; Jackson, Karen E.

    2008-01-01

    A 5-ft-diameter composite fuselage section was retrofitted with four identical blocks of deployable honeycomb energy absorber and crash tested on two different surfaces: soft soil, and water. The drop tests were conducted at the 70-ft. drop tower at the Landing and Impact Research (LandIR) Facility of NASA Langley. Water drop tests were performed into a 15-ft-diameter pool of water that was approximately 42-in. deep. For the soft soil impact, a 15-ft-square container filled with fine-sifted, unpacked sand was located beneath the drop tower. All drop tests were vertical with a nominally flat attitude with respect to the impact surface. The measured impact velocities were 37.4, and 24.7-fps for soft soil and water, respectively. A fuselage section without energy absorbers was also drop tested onto water to provide a datum for comparison with the test, which included energy absorbers. In order to facilitate this type of comparison and to ensure fuselage survivability for the no-energy-absorber case, the velocity of the water impact tests was restricted to 25-fps nominal. While all tests described in this paper were limited to vertical impact velocities, the implications and design challenges of utilizing external energy absorbers during combined forward and vertical impact velocities are discussed. The design, testing and selection of a honeycomb cover, which was required in soft surface and water impacts to transmit the load into the honeycomb cell walls, is also presented.

  4. Puddle Jumping

    NASA Astrophysics Data System (ADS)

    Wollman, Andrew; Snyder, Trevor; Weislogel, Mark

    2014-11-01

    Rebounding droplets from superhydrophobic surfaces have attracted significant public and scientific attention because they are both enjoyable as well as industrially relevant. Demonstrations of bouncing droplets with volumes between 0.003 and 0.03 ml are common in the literature and limited primarily by gravity. In this presentation we demonstrate large droplet ``rebounds'' made possible by low-gravity testing in a drop tower. The up to 300 ml drops are best described as puddles that launch in a nearly identical manner to rebounding drops 4 orders of magnitude smaller in volume. A variety of jumping liquid and gas puddles are shown including puddles of highly specified and unusual initial geometry. The large length sales of the capillary fluidic surfaces ~ O (10 cm) enable 3D printing of all superhydrophobic surface topologies demonstrated. In addition, we demonstrate such puddle jumping as a passive drop-on-demand technique for large low-gravity drop dynamics investigations; such as collisions, rebounds, heat and mass transfer, and containerless possessing.

  5. Internally damped, self-arresting vertical drop-weight apparatus

    NASA Technical Reports Server (NTRS)

    Ambur, Damodar R. (Inventor); Prasad, Chunchu B. (Inventor); Waters, William A. (Inventor); Stockum, Robert W. (Inventor); Walter, Manfred A. (Inventor)

    1994-01-01

    A vertical dropped-weight impact test machine has a dropped-weight barrel vertically supported on upper and lower support brackets. The dropped-weight barrel is chambered to receive a dropped-weight assembly having a latch pin at its upper end, a damping unit in the middle, and a tup at its lower end. The tup is adapted for gathering data during impact testing. The latch pin releasably engages a latch pin coupling assembly. The latch pin coupling assembly is attached to a winch via a halyard for raising and lowering the dropped-weight assembly. The lower end of the dropped-weight barrel is provided with a bounce-back arresting mechanism which is activated by the descending passage of the dropped-weight assembly. After striking the specimen, the dropped-weight assembly rebounds vertically and is caught by the bounce-back arresting mechanism. The damping unit of the dropped-weight assembly serves to dissipate energy from the rebounding dropped-weight assembly and prevents the dropped-weight assembly from rebounding from the self-arresting mechanism.

  6. Evaluation of Two Crew Module Boilerplate Tests Using Newly Developed Calibration Metrics

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Reaves, Mercedes C.

    2012-01-01

    The paper discusses a application of multi-dimensional calibration metrics to evaluate pressure data from water drop tests of the Max Launch Abort System (MLAS) crew module boilerplate. Specifically, three metrics are discussed: 1) a metric to assess the probability of enveloping the measured data with the model, 2) a multi-dimensional orthogonality metric to assess model adequacy between test and analysis, and 3) a prediction error metric to conduct sensor placement to minimize pressure prediction errors. Data from similar (nearly repeated) capsule drop tests shows significant variability in the measured pressure responses. When compared to expected variability using model predictions, it is demonstrated that the measured variability cannot be explained by the model under the current uncertainty assumptions.

  7. A new injury prevention programme for children's football--FIFA 11+ Kids--can improve motor performance: a cluster-randomised controlled trial.

    PubMed

    Rössler, R; Donath, L; Bizzini, M; Faude, O

    2016-01-01

    The present study evaluated the effects of a newly developed injury prevention programme for children's football ("FIFA 11+ Kids") on motor performance in 7-12-year-old children. We stratified 12 football teams (under-9/-11/-13 age categories) into intervention (INT, N = 56 players) and control groups (CON, N = 67). INT conducted the 15-min warm-up programme "FIFA 11+ Kids" twice a week for 10 weeks. CON followed a standard warm-up (sham treatment). Pre- and post-tests were conducted using: single leg stance; Y-balance test; drop and countermovement jump; standing long jump; 20-m sprint; agility run; slalom dribble; and wall volley test. We used magnitude-based inferences and linear mixed-effects models to analyse performance test results. We observed likely beneficial effects favouring INT in Y-balance (right leg; +3.2%; standardised mean difference (SMD) = 0.34; P = 0.58) and agility run (+3.6%; SMD = 0.45; P = 0.008). Possibly beneficial effects were found in Y-balance, drop jump reactive strength index, drop jump height, countermovement jump, standing long jump, slalom dribble and wall volley test. At least possibly beneficial improvements in favour of "FIFA 11+ Kids" were observed in nearly all parameters. Most effects were small, but slight improvements in motor performance may potentially contribute to a reduction of injury risk.

  8. Max Launch Abort System (MLAS) Landing Parachute Demonstrator (LPD) Drop Test

    NASA Technical Reports Server (NTRS)

    Shreves, Christopher M.

    2011-01-01

    The Landing Parachute Demonstrator (LPD) was conceived as a low-cost, rapidly-developed means of providing soft landing for the Max Launch Abort System (MLAS) crew module (CM). Its experimental main parachute cluster deployment technique and off-the-shelf hardware necessitated a full-scale drop test prior to the MLAS mission in order to reduce overall mission risk. This test was successfully conducted at Wallops Flight Facility on March 6, 2009, with all vehicle and parachute systems functioning as planned. The results of the drop test successfully qualified the LPD system for the MLAS flight test. This document captures the design, concept of operations and results of the drop test.

  9. Operation REDWING 1956

    DTIC Science & Technology

    1982-08-01

    AIRCRAFT UNIT Hq TAU 2 0 1 0 Eniwetok Is. 20 Mar Hq USAF Elm 0 4 0 0 Eniwetok Is. 30 Apr Hq USAF Elm 4 3 2 0 Parry Is. 30 Apr 4g Drop & Cann Elm 15 41 0...0 Eniwrv k Is. 1 5-36 16 Mar i 4 2 5-52 mqý Effects Elm 14 7 8 53 Eniwecck Is. 1 B-52 21 Mar 1 B-47 I B-57 1 B-66 2 F-84F 1 F-101 IBDA Elm 11 35 0 0...Eniwetok Is. 3 B-47 30 Apr Ionosphere Elm 6 12 0 0 Eniwetok Is. 1 C-97 30 Apr * "Navy Effects Elm 8 31 13 0 I A3D "I P2V Early Pe.ietr Elm 16 40 0 0

  10. Soccer Player Characteristics in English Lower-League Development Programmes: The Relationships between Relative Age, Maturation, Anthropometry and Physical Fitness.

    PubMed

    Lovell, Ric; Towlson, Chris; Parkin, Guy; Portas, Matt; Vaeyens, Roel; Cobley, Stephen

    2015-01-01

    The relative age effect (RAE) and its relationships with maturation, anthropometry, and physical performance characteristics were examined across a representative sample of English youth soccer development programmes. Birth dates of 1,212 players, chronologically age-grouped (i.e., U9's-U18's), representing 17 professional clubs (i.e., playing in Leagues 1 & 2) were obtained and categorised into relative age quartiles from the start of the selection year (Q1 = Sep-Nov; Q2 = Dec-Feb; Q3 = Mar-May; Q4 = Jun-Aug). Players were measured for somatic maturation and performed a battery of physical tests to determine aerobic fitness (Multi-Stage Fitness Test [MSFT]), Maximal Vertical Jump (MVJ), sprint (10 & 20m), and agility (T-Test) performance capabilities. Odds ratio's (OR) revealed Q1 players were 5.3 times (95% confidence intervals [CI]: 4.08-6.83) more likely to be selected than Q4's, with a particularly strong RAE bias observed in U9 (OR: 5.56) and U13-U16 squads (OR: 5.45-6.13). Multivariate statistical models identified few between quartile differences in anthropometric and fitness characteristics, and confirmed chronological age-group and estimated age at peak height velocity (APHV) as covariates. Assessment of practical significance using magnitude-based inferences demonstrated body size advantages in relatively older players (Q1 vs. Q4) that were very-likely small (Effect Size [ES]: 0.53-0.57), and likely to very-likely moderate (ES: 0.62-0.72) in U12 and U14 squads, respectively. Relatively older U12-U14 players also demonstrated small advantages in 10m (ES: 0.31-0.45) and 20m sprint performance (ES: 0.36-0.46). The data identify a strong RAE bias at the entry-point to English soccer developmental programmes. RAE was also stronger circa-PHV, and relatively older players demonstrated anaerobic performance advantages during the pubescent period. Talent selectors should consider motor function and maturation status assessments to avoid premature and unwarranted drop-out of soccer players within youth development programmes.

  11. Soccer Player Characteristics in English Lower-League Development Programmes: The Relationships between Relative Age, Maturation, Anthropometry and Physical Fitness

    PubMed Central

    Lovell, Ric; Towlson, Chris; Parkin, Guy; Portas, Matt; Vaeyens, Roel; Cobley, Stephen

    2015-01-01

    The relative age effect (RAE) and its relationships with maturation, anthropometry, and physical performance characteristics were examined across a representative sample of English youth soccer development programmes. Birth dates of 1,212 players, chronologically age-grouped (i.e., U9’s-U18’s), representing 17 professional clubs (i.e., playing in Leagues 1 & 2) were obtained and categorised into relative age quartiles from the start of the selection year (Q1 = Sep-Nov; Q2 = Dec-Feb; Q3 = Mar-May; Q4 = Jun-Aug). Players were measured for somatic maturation and performed a battery of physical tests to determine aerobic fitness (Multi-Stage Fitness Test [MSFT]), Maximal Vertical Jump (MVJ), sprint (10 & 20m), and agility (T-Test) performance capabilities. Odds ratio’s (OR) revealed Q1 players were 5.3 times (95% confidence intervals [CI]: 4.08–6.83) more likely to be selected than Q4’s, with a particularly strong RAE bias observed in U9 (OR: 5.56) and U13-U16 squads (OR: 5.45–6.13). Multivariate statistical models identified few between quartile differences in anthropometric and fitness characteristics, and confirmed chronological age-group and estimated age at peak height velocity (APHV) as covariates. Assessment of practical significance using magnitude-based inferences demonstrated body size advantages in relatively older players (Q1 vs. Q4) that were very-likely small (Effect Size [ES]: 0.53–0.57), and likely to very-likely moderate (ES: 0.62–0.72) in U12 and U14 squads, respectively. Relatively older U12-U14 players also demonstrated small advantages in 10m (ES: 0.31–0.45) and 20m sprint performance (ES: 0.36–0.46). The data identify a strong RAE bias at the entry-point to English soccer developmental programmes. RAE was also stronger circa-PHV, and relatively older players demonstrated anaerobic performance advantages during the pubescent period. Talent selectors should consider motor function and maturation status assessments to avoid premature and unwarranted drop-out of soccer players within youth development programmes. PMID:26331852

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frangakis, Constantine; Geschwind, Jean-Francois; Kim, Daniel

    Introduction: The drop-off risk for patients awaiting liver transplantation for hepatocellular carcinoma (HCC) is 22%. Transplant liver availability is expected to worsen, resulting in longer waiting times and increased drop-off rates. Our aim was to determine whether chemoembolization can decrease this risk. Patients and Methods: Eighty-seven consecutive HCC patients listed for liver transplant (Milan criteria) underwent statistical comparability adjustments using the propensity score (Wilcoxon, Fisher's, and chi-square tests). Forty-three nonchemoembolization patients and 22 chemoembolization patients were comparable for Child-Pugh and Model for End-Stage Liver Disease scores, tumor size and number, alpha fetoprotein (AFP) levels, and cause of cirrhosis. We calculatedmore » the risk of dropping off the transplant list by assigning a transplant time to those who dropped off (equal probability with patients who were on the list longer than the patient in question). The significance level was obtained by calculating the simulation distribution of the difference compared with the permutations of chemoembolization versus nonchemoembolization assignment of the patients. Kaplan-Meier estimators (log-rank test) were used to determine survival rates. Results: Median follow-up was 187 {+-} 110 weeks (range 38 to 435, date of diagnosis). The chemoembolization group had an 80% drop-off risk decrease (15% nonchemoembolization versus 3% chemoembolization, p = 0.04). Although survival was better for the chemoembolization group, it did not reach statistical significance. Two-year survival for the nonchemoembolization and chemoembolization group was 57.3% {+-} 7.1% and 76.0% {+-} 7.9%, respectively (p = 0.078). Conclusions: Chemoembolization appears to result in a significant decrease in the risk of dropping off liver transplant list for patients with HCC and results in a tendency toward longer survival.« less

  13. Orion Swing Drop 6

    NASA Image and Video Library

    2017-09-25

    Water impact test of an 18,000-pound (8,165 kilogram) test version of the Orion spacecraft at NASA's Langley Research Center. NASA is swing drop testing this Orion capsule mock-up at Langley's Hydro Impact Basin to certify the actual Orion spacecraft for water landings. In a series of tests, Orion is being dropped in a variety of different conditions to help fine-tune NASA's predictions of Orion's landing loads.

  14. Fabrication of a silica aerogel and examination of its hydrophobic properties via contact angle and 3M water repellency tests

    NASA Astrophysics Data System (ADS)

    Mazrouei-Sebdani, Z.; Javazmi, L.; Khoddami, A.; Shams-Ghahfarokhi, F.; Low, T.

    2017-05-01

    Aerogels are dry gels with a very high specific pore volume. Aerogels with increased hydrophobicity have significant potential to expand their use as lightweight materials. Considering its special nanostructure and exceptional properties, this paper focuses on the synthesis and hydrophobic evaluation of a silica aerogel. The structural properties were investigated by measuring density, SEM micrographs, and BET analyses. Also, the hydrophobic evaluation was carried out by measuring 3M water repellency and water/alcohol contact angle. The BET analysis showed successful synthesis of the nanoporous silica aerogel with a pore size of 24 nm and porosity of 89%. The synthesized aerogel showed 3M water repellency of 3 and water contact angle of 129.6°. Also, it is worth-mentioning that as the alcohol content of the drops in 3M water repellency test is increased, the drop contact angle is decreased due to its lower surface tension. Thus, the contact angle reaches the zero at 3M water repellency test number of 4 (water/alcohol 60/40).

  15. Droplet combustion experiment drop tower tests using models of the space flight apparatus

    NASA Technical Reports Server (NTRS)

    Haggard, J. B.; Brace, M. H.; Kropp, J. L.; Dryer, F. L.

    1989-01-01

    The Droplet Combustion Experiment (DCE) is an experiment that is being developed to ultimately operate in the shuttle environment (middeck or Spacelab). The current experiment implementation is for use in the 2.2 or 5 sec drop towers at NASA Lewis Research Center. Initial results were reported in the 1986 symposium of this meeting. Since then significant progress was made in drop tower instrumentation. The 2.2 sec drop tower apparatus, a conceptual level model, was improved to give more reproducible performance as well as operate over a wider range of test conditions. Some very low velocity deployments of ignited droplets were observed. An engineering model was built at TRW. This model will be used in the 5 sec drop tower operation to obtain science data. In addition, it was built using the flight design except for changes to accommodate the drop tower requirements. The mechanical and electrical assemblies have the same level of complexity as they will have in flight. The model was tested for functional operation and then delivered to NASA Lewis. The model was then integrated into the 5 sec drop tower. The model is currently undergoing initial operational tests prior to starting the science tests.

  16. Desizing of Starch Containing Cotton Fabrics Using Near Atmospheric Pressure, Cold DC Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Prasath, A.; Sivaram, S. S.; Vijay Anand, V. D.; Dhandapani, Saravanan

    2013-03-01

    An attempt has been made to desize the starch containing grey cotton fabrics using the DC plasma with oxygen as the gaseous medium. Process conditions of the plasma reactor were optimized in terms of distance between the plates (3.2 cm), applied voltage (600 V) and applied pressure (0.01 bar) to obtain maximum desizing efficiency. No discolouration was observed in the hot water extracts of the desized sample in presence of iodine though relatively higher solvent extractable impurities (4.53 %) were observed in the plasma desized samples compared to acid desized samples (3.38 %). Also, significant weight loss, improvements in plasma desized samples were observed than that of grey fabrics in terms of drop absorbency.

  17. RELAP5-3D Resolution of Known Restart/Backup Issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mesina, George L.; Anderson, Nolan A.

    2014-12-01

    The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequentialmore » verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.« less

  18. Steroid eye drop treatment (difluprednate ophthalmic emulsion) is effective in reducing refractory diabetic macular edema.

    PubMed

    Nakano, Sakiko; Yamamoto, Teiko; Kirii, Eriko; Abe, Sachi; Yamashita, Hidetoshi

    2010-06-01

    To evaluate the efficacy of treatment of refractory diabetic macular edema (DME) after vitrectomy with difluprednate ophthalmic emulsion 0.05% (Durezol(TM)), and to compare this treatment with sub-Tenon's injection of triamcinolone (STTA). This study enrolled patients with refractory diabetic macular edema that persisted despite pars plana vitrectomy in our clinic. In all subjects, more than 3 months had passed since prior treatment. Eleven eyes in ten subjects were treated with STTA (STTA group), and 11 eyes in seven subjects were treated with difluprednate ophthalmic emulsion 0.05% (Durezol(TM), Sirion Therapeutics Inc., USA) 4 times daily for the first month and then twice daily for 2 months (eye drop group). In the eye drop group, mean VA (+/- SD) was 0.67 +/- 0.35 logMAR and mean retinal thickness was 500.6 +/- 207.7 mum at baseline. After 3 months of treatment, mean VA was 0.67 +/- 0.29 and mean retinal thickness had decreased to 341.2 +/- 194.8 mum. The mean minimum value of RT during the treatment period was 300.6 +/- 123.2 mum, and significantly lower than that at baseline (Mann-Whitney U test: P = 0.003). In the STTA group, mean VA (+/- SD) was 0.67 +/- 0.35 logMAR, and mean retinal thickness was 543.3 +/- 132.6 mum at baseline. After 3 months of treatment, mean VA was 0.49 +/- 0.67, and mean retinal thickness had decreased to 378.6 +/- 135 mum. The mean minimum value of RT during the treatment period was 349.9 +/- 113.8 mum, and significantly lower than at baseline (Mann-Whitney U test: P = 0.003). The rate of effective improvement in RT did not differ between the eye drop group (73%) and STTA group (84%) (Fisher's exact test: P = 1). Comparable improvements of retinal thickness were observed in the STTA and eye drop groups. Instillation of difluprednate ophthalmic emulsion 0.05% is a safe and effective treatment that does not require surgical intervention and does not produce severe side-effects.

  19. Evaluation of lower leg function in patients with Achilles tendinopathy.

    PubMed

    Silbernagel, Karin Grävare; Gustavsson, Alexander; Thomeé, Roland; Karlsson, Jon

    2006-11-01

    Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes. However, the effect that the Achilles tendinopathy has on patients' physical performance is still unclear. The purpose of this study was to evaluate if Achilles tendinopathy caused functional deficits on the injured side compared with the non-injured side in patients. A test battery comprised of tests for different aspects of muscle-tendon function of the gastrocnemius, soleus and Achilles tendon complex was developed to evaluate lower leg function. The test battery's test-retest reliability and sensitivity (the percent probability that the tests would demonstrate abnormal lower limb symmetry index in patients) were also evaluated. The test battery consisted of three jump tests, a counter movements jump (CMJ), a drop counter movement jump (drop CMJ) and hopping, and two strength tests, concentric toe-raises, eccentric-concentric toe-raises and toe-raises for endurance. The reliability was evaluated through a test-retest design on 15 healthy subjects. The test battery's sensitivity and possible functional deficits in patients with Achilles tendinopathy were evaluated on 42 patients (19 women and 23 men). An excellent reliability was found between test days 1-2 and 2-3 for all tests (ICC = 0.76-0.94) except for concentric toe-raise, test 2-3, which had fair reliability (ICC = 0.73). The methodological error ranged from 8 to 17%. There were significant differences (P = 0.001-0.049) between the non-injured (or least symptomatic) side and injured (most symptomatic) side for hopping, drop CMJ, concentric and eccentric-concentric toe-raises, and significant differences (P = 0.000-0.012) in the level of pain during CMJ, hopping, and drop CMJ. The sensitivity of the test battery at a 90% capacity was 88. Achilles tendinopathy causes not only pain and symptoms in patients but also apparent impairments in various aspects of lower leg muscle-tendon function as measured with the test battery. This test battery is reliable and able to detect differences in lower leg function between the injured or "most symptomatic" and non-injured or "least symptomatic" side in patients with Achilles tendinopathy. The test battery has higher demand on patients' function compared with each individual test.

  20. Performance enhanced headgear: a scientific approach to the development of protective headgear.

    PubMed

    McIntosh, A; McCrory, P; Finch, C F

    2004-02-01

    There is a continuing debate about the performance of protective headgear in rugby union, rugby league, and Australian rules football. To examine the impact energy attenuation performance of foam that could be incorporated into headgear and examine the performance of prototypes of modified headgear. Impact tests were conducted on polyethylene foams and protective headgear. Free fall drop tests with a rigid headform on to a flat rigid anvil were conducted. Resultant headform acceleration was measured. Means of the headform acceleration maxima for repeat tests were calculated. Tests on polyethylene foam indicated that an increase in thickness from 10 mm to 16 mm would improve headgear performance. These modifications were incorporated in part into two headgear models: the Albion Headpro and the Canterbury brand Body Armour honeycomb headgear. The headgear tests show that significant reductions in headform acceleration were achieved by increasing the foam density and thickness. Mean headform acceleration maxima for the 16 mm thick modified rugby headgear was about 25% of that of standard headgear for lateral impact 0.3 and 0.4 m drop heights and 27% for the centre front 0.3 m drop tests. At these impacts, the headform acceleration for the modified rugby headgear was below 200 g. Significant improvements in impact energy attenuation performance are possible with small design changes. Whether these are sufficient to reduce the rate or severity of concussion in rugby and Australian rules football can only be shown by formal prospective studies on the field.

  1. Effectiveness of Autologous Serum Eye Drops Combined With Punctal Plugs for the Treatment of Sjögren Syndrome-Related Dry Eye.

    PubMed

    Liu, Ying; Hirayama, Masatoshi; Cui, Xin; Connell, Samuel; Kawakita, Tetsuya; Tsubota, Kazuo

    2015-10-01

    To evaluate the efficacy and safety of autologous serum (AS) eye drops combined with punctal plugs (PPs) in patients with Sjögren syndrome (SS)-related dry eye. A retrospective clinical study was performed in patients with dry eye caused by SS. We evaluated the Schirmer test value, tear breakup time (tBUT), and fluorescein and Rose Bengal (RB) staining scores at baseline, 3 months, 6 months, 1 year, and >1 year after treatment. The dry eye indexes were also evaluated in 2 subgroups, which determined by the using of PPs, including the AS + PP group and AS only group. A total of 56 eyes of 28 patients were investigated with a mean follow-up of 42.3 ± 26.1 months. After the application of AS eye drops, the Schirmer test showed no significant changes. The tBUT (2.7 ± 1.9 seconds) was significantly improved at each time point (3.9 ± 3.1, 4.5 ± 3.1, 3.7 ± 2.5, and 5.1 ± 4.0; P < 0.01), fluorescein staining (4.3 ± 2.8) was significantly improved at each time point (2.2 ± 2.2, 1.9 ± 1.9, 1.8 ± 1.6, and 1.8 ± 1.8; P < 0.01), and RB (2.6 ± 3.0) staining was significantly improved from 6-month treatment (1.5 ± 1.9, 1.9 ± 1.9, and 1.4 ± 1.8; P < 0.05, 0.01, and 0.01, respectively). When combined with PPs, the tBUT and RB staining scores were found to be significantly improved in the AS + PP group compared with those of the AS only group. Long-term application of AS eye drops was found to be an effective and apparently safe treatment for SS dry eye. Furthermore, PPs in combination with AS eye drops were considered to have an additive effect on SS dry eye.

  2. 49 CFR 178.965 - Drop test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Conditioning. Rigid plastic Large Packagings and Large Packagings with plastic inner receptacles must be... having essentially the same physical characteristics. (3) The specific gravity and viscosity of a...

  3. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... any slack. (3) Suspend the dynamic impact system from the helmet by positioning the flexible strap... positions. (3) Dynamic impact apparatus. A dynamic impact apparatus shall be used to apply a shock load to a helmet secured to the test headform. The dynamic impact apparatus shall allow a 4-kg (8.8-lb) drop weight...

  4. Factors Affecting Planting Depth and Standing of Rice Seedling in Parachute Rice Transplanting

    NASA Astrophysics Data System (ADS)

    Astika, I. W.; Subrata, I. D. M.; Pramuhadi, G.

    2018-05-01

    Parachute rice transplanting is a simple and practical rice transplanting method. It can be done manually or mechanically, with various possible designs of machines or tools. This research aimed at quantitatively formulating related factors to the planting depth and standing of rice seedling. Parachute seedlings of rice were grown at several sizes of parachute soil bulb sizes. The trays were specially designed with a 3D printer having bulb sizes 7, 8, 9, 10 mm in square sides and 15 mm depth. At seedling ages of 8-12 days after sowing the seedling bulbs were drops into puddled soil. Soil hardness was set at 3 levels of hardness, measured in hardness index using golf ball test. Angle of dropping was set at 3 levels: 0°, 30°and 45° from the vertical axis. The height of droppings was set at 100 cm, 75 cm, and 50 cm. The relationship between bulb size, height of dropping, soil hardness, dropping angle and planting depth was formulated with ANN. Most of input variables did not significantly affect the planting depth, except that hard soil significantly differs from mild soil and soft soil. The dropping also resulted in various positions of the planted seedlings: vertical standing, sloped, and falling. However, at any position of the planted seedlings, the seedlings would recover themselves into normally vertical position. With this result, the design of planting machinery, as well as the manual planting operation, can be made easier.

  5. 7 CFR 201.53 - Source of seeds for germination.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Source of seeds for germination. 201.53 Section 201.53 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Germination Tests...

  6. 7 CFR 201.53 - Source of seeds for germination.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Source of seeds for germination. 201.53 Section 201.53 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Germination Tests...

  7. 7 CFR 201.53 - Source of seeds for germination.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Source of seeds for germination. 201.53 Section 201.53 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Germination Tests...

  8. Evaluation of efficacy of topical povidone-iodine and different types of fluoroquinolones in the sterilization of bacterial flora on the conjunctiva.

    PubMed

    Coskun, Mehmet; Altintas, Ayse Gul Kocak; Anayol, Mustafa Alpaslan; Raza, Sabri; Celikbilek, Nevreste; Simsek, Saban

    2011-12-01

    To compare the sterilization effectivity of topical povidone-iodine, ciprofloxacin, and ofloxacin on the conjunctival bacterial flora. One hundred sixty-four eyes of 164 patients scheduled for cataract surgery were prospectively analyzed. Conjunctival cultures were obtained 1 day before the surgery without any topical application in all patients. Conjunctival flora was examined in 53 eyes of 53 patients (Group I) 15 min after 5% topical povidone-iodine application on the day of the surgery. Fifty-four eyes of 54 patients (Group II) received 1 drop 0.3% ciprofloxacin at 12 pm 1 day before the operation and 4 drops at 15 min intervals on the day of the surgery. Another 57 eyes of 57 patients (Group III) received 0.3% ofloxacin in the same application mode as ciprofloxacin. Conjunctival cultures were taken in all patients 15 min after last drop of topical antibiotic application. Only coagulase-negative staphylococci were isolated from 75.4% in Group I, 72.2% in Group II, and 59.6% in Group III on pretreatment culture. Different types of bacteria such as Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Proteus spp., Micrococcus spp. were identified in other patients. Pretreatment conjunctival flora of Group I and Group II were similar (P>0.05), but it was significantly different in Group III (P<0.05). After topical application no bacterial growth was observed in 77.3% in Group I, 92.5% in Group II, and 66.6% in Group III. The difference between Group I and III was insignificant (P>0.05), but bacterial eradication effectiveness was significantly higher in Group II than that of other groups (P<0.05). Post-treatment cultures showed same bacterial flora as pretreatment cultures in 14.9% in Group I, 1.8% in Group II, and 19.2% in Group III. The difference between Group I and Group III was statistically insignificant (P>0.05) and the difference between Group II and other groups was statistically significant (P<0.05). Four eyes (7.5%) showed different types of bacterial growth from pretreatment flora in Group I, which were seen in 3 eyes (5.5%) in Group II and in 8 eyes (14%) in Group III. The differences between groups were statistically insignificant (P>0.05). Ciprofloxacin seems to be more effective in conjunctival sterilization. In consideration with high variety of bacterial flora in pretreatment period in ofloxacin group, ofloxacin seems to be superior to povidone-iodine on the reduction of bacterial flora on the conjunctiva.

  9. 49 CFR 178.33b-7 - Design qualification test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Design qualification test. 178.33b-7 Section 178... Specifications for Inside Containers, and Linings § 178.33b-7 Design qualification test. (a) Drop testing. (1) To ensure that creep does not affect the ability of the container to retain the contents, each new design...

  10. 30 CFR 250.527 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and the calculated daily production rate during last well test (oil, gas, basic sediment, and water... (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p) Water depth; (q...: (1) Bleed down/buildup test; (2) Shut-in the well and monitor the pressure drop test; (3) Constant...

  11. Affordable Acoustic Disdrometer: Design, Calibration, Tests

    NASA Astrophysics Data System (ADS)

    van de Giesen, N.; Degen, C.; Hut, R.

    2009-12-01

    It would be a hydrological understatement to say that measuring rainfall correctly is important. Recent years have seen important lowering of the costs of raingauges capable of measuring rainfall intensities. Such raingauges are typically tipping bucket raingauges, connected to an event logger. Costs for such a raingauge are about 100. Accuracy is not always very high, especially during high intensity storms. The moving parts make them vulnerable to slight disruptions such as insects. We set out to design a raingauge without moving parts and at a better price/quality ratio than existing raingauges. After testing several potential candidates, we settled on a very simple piezo ceramic element, which measures the impact of single drops. Such an element costs around 1. The impact of each drop causes an acoustic signal that is transformed into a voltage. A typical impact gives an upswing of up to 1 V and the ringing lasts about 50 ms. With a surface area of about 20 cm2, there is almost never overlap between the signals of different drops. The basic assumption is that each drop will have reached terminal velocity and that the total energy of the impact can, thereby, be related to drop size. We calibrated this acoustic disdrometer by letting drops of different size fall on the disdrometer. A very encouraging calibration curve was obtained in this way. Further testing consisted of comparisons during rainstorms between the acoustic disdrometer and standard tipping bucket raingauges. During intensive storms, the acoustic disdrometer gave results that were very close to those of a nearby totaling raingauge. The signal of the tipping bucket raingauges was clearly saturated as these were not capable of keeping up with the rain. During low intensity events, tipping bucket raingauges performed better as drops too small to detect by the acoustic disdrometer became a significant part of the total rainfall. In first instance, a simple MP3 player with recording functionality ($50) was used as datalogger and processing was performed with a Matlab script. Presently, processing is done on-board of a simple custom built logger that logs the time and total energy of each drop. Post-processing converts the total energy to drop size and corrects for missing small drops by fitting the pdf’s to known raindrop distributions.

  12. Human Bronchial Epithelial Cell Response to Heavy Particle Exposure

    NASA Astrophysics Data System (ADS)

    Story, Michael; Ding, Liang-Hao; Minna, John; Park, Seong-mi; Peyton, Michael; Larsen, Jill

    2012-07-01

    A battery of non-oncogenically immortalized human bronchial epithelial cells (HBECs) are being used to examine the molecular changes that lead to lung carcinogenesis after exposure to heavy particles found in the free space environment. The goal is to ultimately identify biomarkers of radioresponse that can be used for prediction of carcinogenic risk for fatal lung cancer. Our initial studies have focused on the cell line HBEC3 KT and the isogenic variant HBEC3 KTR53, which overexpresses the RASv12 mutant and where p53 has been knocked down by shRNA, and is considered to be a more oncogenically progressed variant. We have previously described the response of HBEC3 KT at the cellular and molecular level, however, the focus here is on the rate of cellular transformation after HZE radiation exposure and the molecular changes in transformed cells. When comparing the two cell lines we find that there is a maximum rate of cellular transformation at 0.25 Gy when cells are exposed to 1 GeV Fe particles, and, for the HBEC3 KTR53 there are multiple pathways upregulated that promote anchorage independent growth including the mTOR pathway, the TGF-1 pathway, RhoA signaling and the ERK/MAPK pathway as early as 2 weeks after radiation. This does not occur in the HBEC3 KT cell line. Transformed HBEC3 KT cells do not show any morphologic or phenotypic changes when grown as cell cultures. HBEC3 KTR53 cells on the other hand show substantial changes in morphology from a cobblestone epithelial appearance to a mesenchymal appearance with a lack of contact inhibition. This epithelial to mesenchymal change in morphology is accompanied by the expression of vimentin and a reduction in the expression of E-cadherin, which are hallmarks of epithelial to mesenchymal transition. Interestingly, for HBEC3 KT transformed cells there are no mutations in the p53 gene, 2 of 15 clones were found to be heterozygous for the RASV12 mutation, and 3 of 15 clones expressed high levels of BigH3, a TGFB-responsive gene associated with loss of cell anchorage. There is also a range of aneuploidy amongst the transformed clones and ongoing chromosomal analysis by array-based comparative genomic hybridization has identified single or two copy loss of the tumor suppressor gene FHIT, in 8 of 15 transformed clones. This is accompanied by a 6-fold reduction, overall, in FHIT gene expression amongst the 15 clones under examination. Interestingly, in spite of these changes at the molecular level, when implanted subcutaneously into immune-compromised mice, the transformed clones from the HBEC3 KT cell line do not form tumors. This suggests that additional hits are required for oncogenesis, at least in a subcutaneous model, and/or, 2-D tissue culture models to not adequately reflect the underlying biology. We have therefore, begun to examine transformation in a 3-D tissue culture model, bronchocysts, where HBEC cells ultimately differentiate and stop cycling. We have shown that cells in 3-D have reduced gene expression of key DNA repair genes, and are less effective at repairing complex damage. We are now irradiating at dose rates as low as 0.2 cGy/min to test the notion of an inverse dose rate effect for carcinogenesis by HZE particles. In our early experiments we have shown that as the dose rate dropped from 20 cGy/min to 0.2 cGy/min, for the same total dose (0.25 and 0.50 Gy) an increasing percentage of bronchocysts become mis-shapen, suggesting that some cells within the cyst have de-differentiated and have reentered the cell cycle. We are now testing whether those cells are, in fact, cycling and wherther they are transformed by disaggregating the cyst and placing the cells into soft agar culture.

  13. ASSESSMENT OF FUNCTIONAL CHANGES TEAR PRODUCTION UNDER THE ACTION OF THE EYE DROPS ON THE BASE OF NATURAL MOLECULE OF ECTOINE AND ARTIFICIAL TEARS IN PATIENTS WITH DRY EYE SYNDROME ON THE BACKGROUND OF ENDOCRINE OPHTHALMOPATHY.

    PubMed

    Veselovskaya, N N; Zherebko, I B

    Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.

  14. MHD (magnetohydrodynamics) channel development: Quarterly report for January 1987-March 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-04-01

    During the report period several slag doping tests were performed. Four of these tests are described in this report. The results were generally encouraging. Four dopants were investigated: Fe/sub 2/O/sub 3/, Fe/sub 3/O/sub 4/, MnO, and CrO/sub 2/. All but the CrO/sub 2/ proved effective within some range of dopant flow rate. At flow rates above or below this range none of the dopants were desirable. The proper ranges for each of the dopants was coarsely mapped in these experiments. When the dopants were injected directly on the anode wall a power increase was observed. This indicates a possible reductionmore » in the voltage drop due to the presence of the dopant. No power gain or loss was observed when the dopant was injected on the cathode wall. However, inter-cathode voltages were observed to spread more uniformly along the wall. High voltages decreased and low voltages increased. This result should help to reduce wear on the cathodes and their neighboring wall elements by reducing the local electrical field. Current control circuits were tested on both MK VI and MK VII type generators and components for consolidation circuits ordered. Solutions to waste disposal problems created by the implementation of new environmental regulations are being investigated. The MHD generator data from the CDIF 87-SEED-1, 87-SEED-2, and 87-SEED-3 tests have been analyzed and the results are presented in this report. The results of the SIDA model presented in this quarterly report are obtained by assuming a constant boundary layer voltage drop. Variations in the boundary layer voltage drop as a result of diagonal loading changes, iron oxide addition, or seeding rates changes were not considered. Corrections for the effects of ..delta..V/sub b1/ will be made to the results of SIDA when the voltage drop measurements become available.« less

  15. Innovative application of Cox Flexion Distraction Decompression to the knee: a retrospective case series

    PubMed Central

    Albano, Luigi

    2017-01-01

    Objective The purpose of this study is to introduce the application of Cox flexion distraction decompression as an innovative approach to treating knee pain and osteoarthritis. Methods Six months of clinical files from one chiropractic practice were retrospectively screened for patients who had been treated for knee pain. Twenty-five patients met the criteria for inclusion. The treatment provided was Cox flexion distraction decompression. Pre-treatment and post-treatment visual analog pain scales (VAS) were used to measure the results. In total, eight patients presented with acute knee pain (less than three months’ duration) and 18 patients presented with chronic knee pain (greater than three months) including two patients with continued knee pain after prosthetic replacement surgery. Results For all 25 patients, a change was observed in the mean VAS scores from 7.7 to 1.8. The mean number of treatments was 5.3 over an average of 3.0 weeks. Acute patient mean VAS scores dropped from 8.1 to 1.1 within 4.8 treatments over 2.4 weeks. Chronic patient mean VAS scores dropped from 7.5 to 2.2 within 5.4 treatments over 3.3 weeks. No adverse events were reported. Conclusion This study showed clinical improvement in patients with knee pain who were managed with Cox flexion distraction decompression applied to the knee. PMID:28928498

  16. 40 CFR Table 4 to Subpart Kkkkk of... - Requirements for Performance Tests

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... block average pressure drop values for the three test runs, and determine and record the 3-hour block... limit for the limestone feeder setting Data from the limestone feeder during the performance test You must ensure that you maintain an adequate amount of limestone in the limestone hopper, storage bin...

  17. Adaptation of running pattern to the drop of standard cushioned shoes: A randomised controlled trial with a 6-month follow-up.

    PubMed

    Malisoux, Laurent; Gette, Paul; Chambon, Nicolas; Urhausen, Axel; Theisen, Daniel

    2017-08-01

    While several cross-sectional studies have investigated the acute effects of shoe drop on running biomechanics, the long-term consequences are currently unknown. This study aimed to investigate if the drop of standard cushioned shoes induces specific adaptations in running technique over a six-month period in leisure-time runners. Double-blinded randomised controlled trial. The participants (n=59) received a pair of shoes with a heel-to-toe drop of 10mm (D10), 6mm (D6) or 0mm (D0) and were followed-up regarding running training over 6 months or 500km, whichever came first. Spatio-temporal variables and kinematics (foot/ground, ankle and knee joint angles) were investigated while running at preferred speed on a treadmill before and after the follow-up. The participants ran 332±178km in the study shoes between pre- and post-tests. There was no shoe version by time interaction for any of the spatio-temporal variables nor for lower limb angles at initial ground contact. A small but significant shoe drop effect was found for knee abduction at mid-stance (p=0.032), as it decreased for the D0 version (-0.3±3.1 vs. -1.3±2.6°) while it increased for the D6 (0.3±2.7 vs. 1.3±3.1°) and D10 version (-0.2±3.2 vs. 0.5±3.1°). However, none of the pairwise comparisons was significant in the post-hoc analysis. Apart from knee abduction at mid-stance, no specific adaptation in spatio-temporal variables and kinematics was found between the three shoe versions during this 6-month follow-up. Thus, shoe drop of standard cushioned shoes does not seem to influence running biomechanics in the long term. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. The chording effect on core losses of three-phase induction motor under sinusoidal and PWM voltage supplies

    NASA Astrophysics Data System (ADS)

    Deshmukh, Ram; Moses, A. J.; Anayi, F.

    The core losses and the lower-order voltage harmonics of four different chorded motors fed from sinusoidal supply and inverter voltage supply were invigilated at no-load condition. All the four motors were tested with 4, 8 and 16 kHz switching frequencies and 30, 40, 50 and 60 Hz modulation frequencies The motor with 120° coil pitch has the least core losses and the lower-order voltage harmonics under sinusoidal and pulse width modulation (PWM) voltage supplies at all switching and modulation frequencies. The drop in the core losses for this motor was 46% and 53% under sinusoidal and PWM voltage supplies, respectively. The motor with 120° coil pitch is recommended to be used under sinusoidal and PWM voltage supplies.

  19. PHISICS/RELAP5-3D Adaptive Time-Step Method Demonstrated for the HTTR LOFC#1 Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Robin Ivey; Balestra, Paolo; Strydom, Gerhard

    A collaborative effort between Japan Atomic Energy Agency (JAEA) and Idaho National Laboratory (INL) as part of the Civil Nuclear Energy Working Group is underway to model the high temperature engineering test reactor (HTTR) loss of forced cooling (LOFC) transient that was performed in December 2010. The coupled version of RELAP5-3D, a thermal fluids code, and PHISICS, a neutronics code, were used to model the transient. The focus of this report is to summarize the changes made to the PHISICS-RELAP5-3D code for implementing an adaptive time step methodology into the code for the first time, and to test it usingmore » the full HTTR PHISICS/RELAP5-3D model developed by JAEA and INL and the LOFC simulation. Various adaptive schemes are available based on flux or power convergence criteria that allow significantly larger time steps to be taken by the neutronics module. The report includes a description of the HTTR and the associated PHISICS/RELAP5-3D model test results as well as the University of Rome sub-contractor report documenting the adaptive time step theory and methodology implemented in PHISICS/RELAP5-3D. Two versions of the HTTR model were tested using 8 and 26 energy groups. It was found that most of the new adaptive methods lead to significant improvements in the LOFC simulation time required without significant accuracy penalties in the prediction of the fission power and the fuel temperature. In the best performing 8 group model scenarios, a LOFC simulation of 20 hours could be completed in real-time, or even less than real-time, compared with the previous version of the code that completed the same transient 3-8 times slower than real-time. A few of the user choice combinations between the methodologies available and the tolerance settings did however result in unacceptably high errors or insignificant gains in simulation time. The study is concluded with recommendations on which methods to use for this HTTR model. An important caveat is that these findings are very model-specific and cannot be generalized to other PHISICS/RELAP5-3D models.« less

  20. Inverted drop testing and neck injury potential.

    PubMed

    Forrest, Stephen; Herbst, Brian; Meyer, Steve; Sances, Anthony; Kumaresan, Srirangam

    2003-01-01

    Inverted drop testing of vehicles is a methodology that has long been used by the automotive industry and researchers to test roof integrity and is currently being considered by the National Highway Traffic Safety Administration as a roof strength test. In 1990 a study was reported which involved 8 dolly rollover tests and 5 inverted drop tests. These studies were conducted with restrained Hybrid III instrumented Anthropometric Test Devices (ATD) in production and rollcaged vehicles to investigate the relationship between roof strength and occupant injury potential. The 5 inverted drop tests included in the study provided a methodology producing "repeatable roof impacts" exposing the ATDs to the similar impact environment as those seen in the dolly rollover tests. Authors have conducted two inverted drop test sets as part of an investigation of two real world rollover accidents. Hybrid-III ATD's were used in each test with instrumented head and necks. Both test sets confirm that reduction of roof intrusion and increased headroom can significantly enhance occupant protection. In both test pairs, the neck force of the dummy in the vehicle with less crush and more survival space was significantly lower. Reduced roof crush and dynamic preservation of the occupant survival space resulted in only minor occupant contact and minimal occupant loading, establishing a clear causal relationship between roof crush and neck injuries.

  1. Prevalence of ocular symptoms and signs with preserved and preservative free glaucoma medication

    PubMed Central

    Pisella, P J; Pouliquen, P; Baudouin, C

    2002-01-01

    Aim: To determine the incidence of ocular toxicity of preservatives with glaucoma medications. Methods: A prospective epidemiological survey was carried out in 1999 by 249 ophthalmologists on 4107 patients. Ocular symptoms, conjunctiva, cornea, and eyelids were assessed. A χ2 test was used for differences between preserved eye drops (P) and preservative free eye drops (PF). Results: 84% patients used P, 13% received PF, and 3% a combination of P and PF eye drops. All symptoms were more prevalent with P than with PF drops (p<0.001): discomfort upon instillation (43% versus 17%), and symptoms between instillations such as burning-stinging (40% versus 22%), foreign body sensation (31% versus 14%), dry eye sensation (23% versus 14%), tearing (21% versus 14%), and eyelid itching (18% versus 10%). An increased incidence (>2 times) of ocular signs was seen with P eye drops. The prevalence of signs and symptoms was dose dependent, increasing with the number of P drops. A reduction in the symptoms and signs was observed when patients changed from P to PF eye drops (p<0.001). Conclusions: Symptoms and signs are less prevalent when PF drops are used. Moreover, most of the adverse reactions induced by P glaucoma medication are reversible after removing preservatives. PMID:11914211

  2. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 3: Data from crew module testing

    NASA Technical Reports Server (NTRS)

    Shane, S. J.

    1985-01-01

    Over the past years, several papers and reports have documented the unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft. This report documents a program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats. An energy absorbing test seat was designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions, was conducted at a sled test facility. Comparative tests with operational F-111 crewseats were also conducted. After successful dynamic testing of the seat, more testing was conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests werre conducted. The vertical drop tests were used to obtain comparative data between the energy absorbing and operational seats.

  3. [Safety and efficacy of a new preservative-free levocabastine ophthalmic solution (Levofree®) using the conjunctival provocation test].

    PubMed

    Allaire, C; Siou-Mermet, R; Bassols, A

    2012-09-01

    To evaluate the safety and efficacy of preservative-free levocabastine 0.05 % ophthalmic solution compared to placebo (vehicle) and to preserved levocabastine 0.05 % ophthalmic suspension in the prevention of allergic conjunctivitis induced by a conjunctival provocation test. Ninety-two subjects (18-50 years) with a previous history of allergic conjunctivitis to pollen were randomised to receive either preservative-free levocabastine solution in one eye and preserved levocabastine suspension in the fellow eye (n=69), or preservative-free levocabastine in one eye and placebo in the fellow eye (n=23). One drop of each product was administered 10 minutes (visit 3) and 4 hours (visit 4) prior to the provocation test. The primary efficacy criterion was the sum of the itching and conjunctival hyperemia scores assessed at 3, 5 and 10 minutes after the provocation test. The safety evaluation included adverse events, visual acuity, intra-ocular pressure and study drug drop sensation. The efficacy of the preservative-free solution was significantly higher than that of placebo at all time points (P≤0.01) with one exception at visit 4 (3 minutes after the provocation test). It was significantly higher than that of the preserved suspension at visit 3, and equivalent at visit 4. The incidence of adverse events was lower with the preservative-free solution than with the preserved suspension. 94.2 % and 95.7 % subjects rated preservative-free levocabastine drop sensation as "good" or "very good" at visits 3 and 4 respectively, whereas these rates were 68.1 % and 63.8 % with preserved levocabastine. This difference between the two formulations was highly statistically significant (P<0.001). The efficacy of preservative-free levocabastine was superior to that of the placebo and of the preserved suspension at visit 3, at least as effective as the preserved suspension at visit 4, and better tolerated at each visit. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  4. Experimental Study of Grit Particle Enhancement in Non-Shock Ignition

    NASA Astrophysics Data System (ADS)

    Browning, Richard V.; Peterson, Paul D.; Roemer, Edward L.; Oldenborg, Michael R.; Thompson, Darla G.; Deluca, Racci

    2006-07-01

    The drop weight impact test is the most commonly used configuration for evaluating sensitivity of explosives to non-shock ignition. Although developed 60 years ago and widely used both as a material compression test and as a test bed for understanding the ignition process itself, little is known about the flow mechanisms or involvement of grit particles as sensitizing agents. In this paper, we present the results of a series of experiments designed to study the flow mechanisms and events leading up to ignition. The experimental configuration used involves two pellet sizes, 3 and 5 mm in diameter, tested with three conditions: (1) smooth steel anvils, (2) standard flint sandpaper, and (3) shed grit particles loaded between the steel anvils and the pellet faces. Diagnostics include optical micrographs, and scanning electron micrographs. Un-reacted samples show a variety of morphologies, including what appear to be quenched reaction sites, even at very low drop heights. Quasi-static crushing experiments were also done to quantify load-time histories.

  5. Experimental Study of Grit Particle Enhancement in Non-Shock Ignition of PBX 9501

    NASA Astrophysics Data System (ADS)

    Peterson, Paul

    2005-07-01

    The drop weight impact test is the most commonly used configuration for evaluating sensitivity of explosives to non-shock ignition. Although developed 60 years ago and widely used both as a material compression test and as a test bed for understanding the ignition process itself, little is known about the flow mechanisms or involvement of grit particles as sensitizing agents. In this paper we present the results of a series of experiments designed to study the flow mechanisms and events leading up to ignition. The experimental configuration used involves two pellet sizes, 3 and 5 mm in diameter, tested in three conditions, (1) with smooth steel anvils, (2) with standard flint sandpaper, and (3) with shed grit particles loaded between the steel anvils and the pellet faces. Diagnostics include optical micrographs, and scanning electron micrographs. Un-reacted samples show a variety of morphologies, including what appear to be quenched reaction sites, even at very low drop heights. Quasi-static crushing experiments were also done to quantify load-time histories.

  6. Drop-Weight Impact Test on U-Shape Concrete Specimens with Statistical and Regression Analyses

    PubMed Central

    Zhu, Xue-Chao; Zhu, Han; Li, Hao-Ran

    2015-01-01

    According to the principle and method of drop-weight impact test, the impact resistance of concrete was measured using self-designed U-shape specimens and a newly designed drop-weight impact test apparatus. A series of drop-weight impact tests were carried out with four different masses of drop hammers (0.875, 0.8, 0.675 and 0.5 kg). The test results show that the impact resistance results fail to follow a normal distribution. As expected, U-shaped specimens can predetermine the location of the cracks very well. It is also easy to record the cracks propagation during the test. The maximum of coefficient of variation in this study is 31.2%; it is lower than the values obtained from the American Concrete Institute (ACI) impact tests in the literature. By regression analysis, the linear relationship between the first-crack and ultimate failure impact resistance is good. It can suggested that a minimum number of specimens is required to reliably measure the properties of the material based on the observed levels of variation. PMID:28793540

  7. Improving the rainfall rate estimation in the midstream of the Heihe River Basin using raindrop size distribution

    NASA Astrophysics Data System (ADS)

    Zhao, G.; Chu, R.; Zhang, T.; Li, J.; Shen, J.; Wu, Z.

    2011-03-01

    During the intensive observation period of the Watershed Allied Telemetry Experimental Research (WATER), a total of 1074 raindrop size distribution were measured by the Parsivel disdrometer, the latest state-of-the-art optical laser instrument. Because of the limited observation data in Qinghai-Tibet Plateau, the modelling behaviour was not well done. We used raindrop size distributions to improve the rain rate estimator of meteorological radar in order to obtain many accurate rain rate data in this area. We got the relationship between the terminal velocity of the raindrop and the diameter (mm) of a raindrop: v(D) = 4.67D0.53. Then four types of estimators for X-band polarimetric radar are examined. The simulation results show that the classical estimator R (ZH) is most sensitive to variations in DSD and the estimator R (KDP, ZH, ZDR) is the best estimator for estimating the rain rate. An X-band polarimetric radar (714XDP) is used for verifying these estimators. The lowest sensitivity of the rain rate estimator R (KDP, ZH, ZDR) to variations in DSD can be explained by the following facts. The difference in the forward-scattering amplitudes at horizontal and vertical polarizations, which contributes KDP, is proportional to the 3rd power of the drop diameter. On the other hand, the exponent of the backscatter cross-section, which contributes to ZH, is proportional to the 6th power of the drop diameter. Because the rain rate R is proportional to the 3.57th power of the drop diameter, KDP is less sensitive to DSD variations than ZH.

  8. Heat transfer tests of an 0.006-scale thin-skin space shuttle model (41-OTS) in the Ames 3.5-foot HWT at M equals 5.3 (IH15)

    NASA Technical Reports Server (NTRS)

    Walstad, D. G.; Lockman, W. K.

    1974-01-01

    Data obtained from heat transfer tests of an 0.006-scale space shuttle vehicle in a 3.5-foot hypersonic wind tunnel are presented. The purpose of these tests was to parametrically investigate the ascent heating of the integrated vehicle. Configurations tested were complete for integrated vehicle, orbiter alone, external tank alone, and SRB alone. All configurations were tested with and without transition grit. Testing was conducted at a Mach number of 5.3, and at Reynolds numbers of 2 and 5 million per foot. The angle of attack range varied from 0 to minus 5 degress, execpt for SRB alone, which was tested from minus 5 to 90 degrees. Heat transfer data were obtained from 223 iron-constantan thermocouples attached to thin-skin stainless steel inserts.

  9. The prevalence of incidental simple ovarian cysts >or= 3 cm detected by transvaginal sonography in early pregnancy.

    PubMed

    Glanc, Phyllis; Brofman, Nicole; Salem, Shia; Kornecki, Anat; Abrams, Jason; Farine, Dan

    2007-06-01

    To determine the prevalence of simple ovarian cysts of >or= 3 cm diameter detected by transvaginal sonography (TVS) in a population of asymptomatic women in early pregnancy. We conducted a retrospective review of 10,830 consecutive women presenting prior to 14 weeks' gestational age (GA) for early dating TVS. The records of all women with simple cysts >or= 3 cm in diameter were included. The study population was divided into five groups by GA: >or= 6 weeks; 6.1-8 weeks; 8.1-10 weeks; 10.1-12 weeks; and 12.1-14 weeks. A simple cyst >or= 3 cm in diameter was present in 4.9% of women at >or= 6 weeks' gestation, in 5.1% between 6.1 and 8 weeks, in 5.3% between 8.1 and 10 weeks, in 3.2% between 10.1. and 12 weeks, and in 1.5% between 12 and 14 weeks. Overall, a simple cyst >or= 3 cm was present in 516 women (4.8%). Prior to 10 weeks, 5.1% had simple cysts >or= 3 cm, dropping to 2.7% after 10 weeks, a statistically significant decrease (P<0.0001). Between 10.1 weeks and 12 weeks, the prevalence dropped to 3.2%, and then to 1.5% in the 12.1-14 week group. This investigation provides reference data on the prevalence of detecting simple ovarian cysts >or= 3 cm by TVS in an asymptomatic early pregnancy population. A progressive decline in the frequency of detecting simple ovarian cysts >or= 3 cm begins after 10 weeks' gestational age.

  10. Desire for female sterilization among women wishing to limit births in rural Rakai, Uganda

    PubMed Central

    Lutalo, Tom; Gray, Ron; Mathur, Sanyukta; Wawer, Maria; Guwatudde, David; Santelli, John; Nalugoda, Fred; Makumbi, Fredrick

    2015-01-01

    Objective Uganda has an unmet need for family planning of 34% and a total fertility rate of 6.2. We assessed the desire for female sterilization among sexually active women who wanted to stop childbearing in rural Rakai district, Uganda. Study design 7,192 sexually active women enrolled in a community cohort between 2002 and 2008 were asked about fertility intentions. Those stating that they did not want another child (limiters) were asked whether they would be willing to accept female sterilization, if available. Trends in desire for sterilization were determined by Chi-square test for trend, and Modified Poisson regression was used to estimate prevalence rate ratios (PRR) and 95% confidence intervals of the associations between desire for sterilization and socio-demographic characteristics and HIV status. Results From 2002 to 2008, the proportion of limiters dropped (47.2% to 43.7%; p<0.01). Use of pills and injectables among limiters significantly increased, 38.9% to 50.3% (p<0.0001), while use of IUDs and implants declined from 3.3% to 1.7% (p<0.001). The desire for sterilization significantly increased from 54.2% to 63.1% (p<0.0001), and this was consistently higher among the HIV-positive (63.6% to 70.9%, p<0.01) than HIV-negative women (53.3% to 61.2%, p<0.0001). Factors significantly associated with the desire for sterilization included higher number of living children (>=3), being HIV-infected and having received HIV counseling and testing. Conclusion There is latent and growing desire for sterilization in this population. Our findings suggest a need to increase permanent contraception services for women who want to limit childbearing in this setting. PMID:26232377

  11. p53 Reactivation by PRIMA-1(Met) (APR-246) sensitises (V600E/K)BRAF melanoma to vemurafenib.

    PubMed

    Krayem, Mohammad; Journe, Fabrice; Wiedig, Murielle; Morandini, Renato; Najem, Ahmad; Salès, François; van Kempen, Leon C; Sibille, Catherine; Awada, Ahmad; Marine, Jean-Christophe; Ghanem, Ghanem

    2016-03-01

    Intrinsic and acquired resistance of metastatic melanoma to (V600E/K)BRAF and/or MEK inhibitors, which is often caused by activation of the PI3K/AKT survival pathway, represents a major clinical challenge. Given that p53 is capable of antagonising PI3K/AKT activation we hypothesised that pharmacological restoration of p53 activity may increase the sensitivity of BRAF-mutant melanoma to MAPK-targeted therapy and eventually delay and/or prevent acquisition of drug resistance. To test this possibility we exposed a panel of vemurafenib-sensitive and resistant (innate and acquired) (V600E/K)BRAF melanomas to a (V600E/K)BRAF inhibitor (vemurafenib) alone or in combination with a direct p53 activator (PRIMA-1(Met)/APR-246). Strikingly, PRIMA-1(Met) synergised with vemurafenib to induce apoptosis and suppress proliferation of (V600E/K)BRAF melanoma cells in vitro and to inhibit tumour growth in vivo. Importantly, this drug combination decreased the viability of both vemurafenib-sensitive and resistant melanoma cells irrespectively of the TP53 status. Notably, p53 reactivation was invariably accompanied by PI3K/AKT pathway inhibition, the activity of which was found as a dominant resistance mechanism to BRAF inhibition in our lines. From all various combinatorial modalities tested, targeting the MAPK and PI3K signalling pathways through p53 reactivation or not, the PRIMA-1(Met)/vemurafenib combination was the most cytotoxic. We conclude that PRIMA-1(Met) through its ability to directly reactivate p53 regardless of the mechanism causing its deactivation, and thereby dampen PI3K signalling, sensitises (V600E/K)BRAF-positive melanoma to BRAF inhibitors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Influence of Electrification of Droplet on Hydrophobicity Reduction of Polymer Material during a Dynamic Drop Test

    NASA Astrophysics Data System (ADS)

    Haji, Kenichi; Shiibara, Daiki; Arata, Yoshihiro; Sakoda, Tatsuya; Otsubo, Masahisa

    The dynamic drop test was proposed as a method to evaluate hydrophobicity reduction of polymer materials. In this test, the formation change of a water channel was confirmed, and thereafter, the remained droplets and the dropped droplets on the sampled surface were repulsed each other. The distributions of electrification on the droplet and the sample surface were measured. The influence of the electrified droplet on the hydrophobicity reduction was examined. The results showed that the polarity on the sample surface changed by the dropped droplet, leading to the hydrophobicity loss.

  13. 3D-printing of undisturbed soil imaged by X-ray

    NASA Astrophysics Data System (ADS)

    Bacher, Matthias; Koestel, John; Schwen, Andreas

    2014-05-01

    The unique pore structures in Soils are altered easily by water flow. Each sample has a different morphology and the results of repetitions vary as well. Soil macropores in 3D-printed durable material avoid erosion and have a known morphology. Therefore potential and limitations of reproducing an undisturbed soil sample by 3D-printing was evaluated. We scanned an undisturbed soil column of Ultuna clay soil with a diameter of 7 cm by micro X-ray computer tomography at a resolution of 51 micron. A subsample cube of 2.03 cm length with connected macropores was cut out from this 3D-image and printed in five different materials by a 3D-printing service provider. The materials were ABS, Alumide, High Detail Resin, Polyamide and Prime Grey. The five print-outs of the subsample were tested on their hydraulic conductivity by using the falling head method. The hydrophobicity was tested by an adapted sessile drop method. To determine the morphology of the print-outs and compare it to the real soil also the print-outs were scanned by X-ray. The images were analysed with the open source program ImageJ. The five 3D-image print-outs copied from the subsample of the soil column were compared by means of their macropore network connectivity, porosity, surface volume, tortuosity and skeleton. The comparison of pore morphology between the real soil and the print-outs showed that Polyamide reproduced the soil macropore structure best while Alumide print-out was the least detailed. Only the largest macropore was represented in all five print-outs. Printing residual material or printing aid material remained in and clogged the pores of all print-out materials apart from Prime Grey. Therefore infiltration was blocked in these print-outs and the materials are not suitable even though the 3D-printed pore shapes were well reproduced. All of the investigated materials were insoluble. The sessile drop method showed angles between 53 and 85 degrees. Prime Grey had the fastest flow rate; the other conducting materials had slow or non-reproducible flow rates. Since only Prime Grey was able to print-out the largest macropore in a discontinuous way, the morphological differences between the five print-outs were not evaluated. Each material has its limitations but only Prime Greys morphology was sufficiently printed and no clogging with residual material occurred. Polyamide and High Detail Resin had clogged pores but were matching the soil's macropore morphology better but further research on removal of residual material blocking pores is needed before they are useable.

  14. The contribution of p53 and Y chromosome long arm genes to regulation of apoptosis in mouse testis.

    PubMed

    Lech, Tomasz; Styrna, Józefa; Kotarska, Katarzyna

    2018-03-01

    Apoptosis of excessive or defective germ cells is a natural process occurring in mammalian testes. Tumour suppressor protein p53 is involved in this process both in developing and adult male gonads. Its contribution to testicular physiology is known to be modified by genetic background. The aim of this study was to evaluate the combined influence of the p53 and Y chromosome long arm genes on male germ cell apoptosis. Knockout of the transformation related protein 53 (Trp53) gene was introduced into congenic strains: B10.BR (intact Y chromosome) and B10.BR-Ydel (Y chromosome with a deletion in the long arm). The level of apoptosis in the testes of 19-day-old and 3-month-old male mice was determined using the terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate in situ nick-end labelling (TUNEL) method. The study revealed that although p53 is involved in germ cell apoptosis in peripubertal testes, this process can also be mediated by p53-independent mechanisms. However, activation of p53-independent apoptotic pathways in the absence of the p53 protein requires engagement of the multicopy Yq genes and was not observed in gonads of B10.BR-Ydel-p53-/- males. The role of Yq genes in the regulation of testicular apoptosis seems to be restricted to the initial wave of spermatogenesis and is not evident in adult gonads. The study confirmed, instead, that p53 does participate in spontaneous apoptosis in mature testes.

  15. What Happens After Health Coaching? Observational Study 1 Year Following a Randomized Controlled Trial

    PubMed Central

    Sharma, Anjana E.; Willard-Grace, Rachel; Hessler, Danielle; Bodenheimer, Thomas; Thom, David H.

    2016-01-01

    PURPOSE Health coaching is effective for chronic disease self-management in the primary care safety-net setting, but little is known about the persistence of its benefits. We conducted an observational study evaluating the maintenance of improved cardiovascular risk factors following a health coaching intervention. METHODS We performed a naturalistic follow-up to the Health Coaching in Primary Care Study, a 12-month randomized controlled trial (RCT) comparing health coaching to usual care for patients with uncontrolled diabetes, hypertension, or hyperlipidemia. Participants were followed up 24 months from RCT baseline. The primary outcome was the proportion at goal for at least 1 measure (hemoglobin A1c, systolic blood pressure, or LDL cholesterol) that had been above goal at enrollment; secondary outcomes included each individual clinical goal. Chi-square tests and paired t-tests compared dichotomous and continuous measures. RESULTS 290 of 441 participants (65.8%) participated at both 12 and 24 months. The proportion of patients in the coaching arm of the RCT who achieved the primary outcome dropped only slightly from 47.1% at 12 to 45.9% at 24 months (P = .80). The proportion at goal for hemoglobin A1c dropped from 53.4% to 36.2% (P = .03). All other clinical metrics had small, nonsignificant changes between 12 and 24 months. CONCLUSIONS Results support the conclusion that most improved clinical outcomes persisted 1 year after the completion of the health coaching intervention. PMID:27184989

  16. What Happens After Health Coaching? Observational Study 1 Year Following a Randomized Controlled Trial.

    PubMed

    Sharma, Anjana E; Willard-Grace, Rachel; Hessler, Danielle; Bodenheimer, Thomas; Thom, David H

    2016-05-01

    Health coaching is effective for chronic disease self-management in the primary care safety-net setting, but little is known about the persistence of its benefits. We conducted an observational study evaluating the maintenance of improved cardiovascular risk factors following a health coaching intervention. We performed a naturalistic follow-up to the Health Coaching in Primary Care Study, a 12-month randomized controlled trial (RCT) comparing health coaching to usual care for patients with uncontrolled diabetes, hypertension, or hyperlipidemia. Participants were followed up 24 months from RCT baseline. The primary outcome was the proportion at goal for at least 1 measure (hemoglobin A1c, systolic blood pressure, or LDL cholesterol) that had been above goal at enrollment; secondary outcomes included each individual clinical goal. Chi-square tests and paired t-tests compared dichotomous and continuous measures. 290 of 441 participants (65.8%) participated at both 12 and 24 months. The proportion of patients in the coaching arm of the RCT who achieved the primary outcome dropped only slightly from 47.1% at 12 to 45.9% at 24 months (P = .80). The proportion at goal for hemoglobin A1c dropped from 53.4% to 36.2% (P = .03). All other clinical metrics had small, nonsignificant changes between 12 and 24 months. Results support the conclusion that most improved clinical outcomes persisted 1 year after the completion of the health coaching intervention. © 2016 Annals of Family Medicine, Inc.

  17. Job Performance Tests for CH-53E Helicopter Mechanics. Volume 2: Administrative Duties and Job Knowledge Tests

    DTIC Science & Technology

    1992-01-01

    SUBTmI.E 5 FU.NDING NUMBERS Job Performance Tests for CII-53E Helicopter Miechanacs - Volume I1: Admiutstrative Duties and Job Knowlede Tests C - N...performance measures to Marine Corps personnel managers . training instructors, and interested researchers who may find them useful. This work comprises...Corps personnel managers , training instructors, and interested researchers who may find them useful. 3. This work comprises two parts: volume I

  18. The structure of dilute combusting sprays

    NASA Technical Reports Server (NTRS)

    Shuen, J. S.; Solomon, A. S. P.; Faeth, F. M.

    1985-01-01

    An experimental and theoretical study of drop processes in a turbulent flame is described. The experiments involved a monodisperse (105 and 180 micro m initial diameter) stream of methanol drops injected at the base of a turbulent methane-fueled diffusion flame burning in still air. The following measurements were made: mean and fluctuating phase velocities, mean drop number flux, drop-size distributions and mean gas-phase temperatures. Measurements were compared with predictions of two separated flow models: (1) deterministic separated flow, where drop-turbulence interactions are ignored; and (2) stochastic separated flow, where drop-turbulence interactions are considered using random-walk computations. The stochastic separated flow analysis yielded best agreement with measurements, since it provides for turbulent dispersion of drops which was important for present test conditions (and probably for most combusting sprays as well). Distinguishing the presence or absence of envelope flames around the drops, however, was relatively unimportant for present test conditions, since the drops spent most of their lifetime in fuel-rich regions of the flow where this distinction is irrelevant.

  19. Combat Helmet-Headform Coupling Characterized from Blunt Impact Events

    DTIC Science & Technology

    2011-11-01

    Testing was completed on a monorail drop tower to analyze the effect of helmet/headform coupling on the blunt impact behavior of ACH helmets using FMVSS...designates its own methods and test equipment: a drop tower ( monorail or twin- wire), headform (DOT, ISO, NOCSAE), headform CG accelerometer (single or...the more anthropomorphic International Standard Organization (ISO) half headform. Testing was completed on a monorail drop tower to analyze the effect

  20. Performance evaluation of Space Shuttle SRB parachutes from air drop and scaled model wind tunnel tests. [Solid Rocket Booster recovery system

    NASA Technical Reports Server (NTRS)

    Moog, R. D.; Bacchus, D. L.; Utreja, L. R.

    1979-01-01

    The aerodynamic performance characteristics have been determined for the Space Shuttle Solid Rocket Booster drogue, main, and pilot parachutes. The performance evaluation on the 20-degree conical ribbon parachutes is based primarily on air drop tests of full scale prototype parachutes. In addition, parametric wind tunnel tests were performed and used in parachute configuration development and preliminary performance assessments. The wind tunnel test data are compared to the drop test results and both sets of data are used to determine the predicted performance of the Solid Rocket Booster flight parachutes. Data from other drop tests of large ribbon parachutes are also compared with the Solid Rocket Booster parachute performance characteristics. Parameters assessed include full open terminal drag coefficients, reefed drag area, opening characteristics, clustering effects, and forebody interference.

  1. Performance enhanced headgear: a scientific approach to the development of protective headgear

    PubMed Central

    McIntosh, A; McCrory, P; Finch, C

    2004-01-01

    Background: There is a continuing debate about the performance of protective headgear in rugby union, rugby league, and Australian rules football. Objectives: To examine the impact energy attenuation performance of foam that could be incorporated into headgear and examine the performance of prototypes of modified headgear. Methods: Impact tests were conducted on polyethylene foams and protective headgear. Free fall drop tests with a rigid headform on to a flat rigid anvil were conducted. Resultant headform acceleration was measured. Means of the headform acceleration maxima for repeat tests were calculated. Results: Tests on polyethylene foam indicated that an increase in thickness from 10 mm to 16 mm would improve headgear performance. These modifications were incorporated in part into two headgear models: the Albion Headpro and the Canterbury brand Body Armour honeycomb headgear. The headgear tests show that significant reductions in headform acceleration were achieved by increasing the foam density and thickness. Mean headform acceleration maxima for the 16 mm thick modified rugby headgear was about 25% of that of standard headgear for lateral impact 0.3 and 0.4 m drop heights and 27% for the centre front 0.3 m drop tests. At these impacts, the headform acceleration for the modified rugby headgear was below 200 g. Conclusions: Significant improvements in impact energy attenuation performance are possible with small design changes. Whether these are sufficient to reduce the rate or severity of concussion in rugby and Australian rules football can only be shown by formal prospective studies on the field. PMID:14751945

  2. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  3. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  4. 14 CFR 27.725 - Limit drop test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... introduced into the drop test by appropriate energy absorbing devices or by the use of an effective mass. (c... critical from the standpoint of the energy to be absorbed by it. (d) When an effective mass is used in...=specified free drop height (inches). L=ration of assumed rotor lift to the rotorcraft weight. d=deflection...

  5. Solid surface wetting and the deployment of drops in microgravity

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Depew, J.

    1994-01-01

    The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simultaneously retracting dual-injector system in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors under dynamic stimuli from the continuous injection flow as well as from the stepped motion of the injectors. The final released drop must have a well determined volume and negligible residual linear or angular momentum. The outcome of Earth-based short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts. They were successfully utilized during the USML-1 Spacelab mission as the primary tips. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module range between 0.3 and 2.7 cm. The tests conducted on-orbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

  6. Solid Surface Wetting and the Deployment of Drops in Microgravity

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Depew, J.

    1994-01-01

    The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simuttaneously retracting dual-injector system used in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors even under dynamic stimuli due to continuous injection flow as well as to the stepped motion of the injectors, and the final released drop must have a well determined volume as well as negligible residual linear or angular momentum from the deployment process. The outcome of Earthbased short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts and were successfully utilized during the USML-1 Spacelab mission. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module ranged between 0.3 and 2.7 cm. The tests conducted onsrbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

  7. Lower cognitive performance in 81-year-old men with greater nocturnal blood pressure dipping

    PubMed Central

    Axelsson, Johan; Reinprecht, Faina; Siennicki-Lantz, Arkadiusz; Elmståhl, Sölve

    2008-01-01

    Abnormal day-to-night blood pressure (BP) pattern have been found to be associated with cerebrovascular damage, yet studies of the elderly 80 years of age and above, for whom the risk pattern may be different due to ageing and age-associated diseases, are lacking. Ninety-seven 81-year-old men underwent ambulatory BP monitoring and were given six cognitive tests, 79 of the men completing the cognitive test battery. The odds ratio (OR) for performing one standard deviation below the mean on any cognitive test was calculated using a forward stepwise logistic regression model, confounding factors being controlled for. Groups defined in terms of day-to-night changes in BP were compared in this respect. Cognitive performance was lower (OR 3.6; P = 0.017) in the group usually described as dippers (10%–20% nocturnal drop in systolic BP [SBP]) as compared with nondippers (<10% drop). The tertile with the greatest SBP fall (10.6%–19.8%, a range considered as normal among middle aged) showed lowest cognitive performance (OR 4.7; P = 0.008) as compared with the middle tertile (5.1%–10.5% drop). The mean nocturnal fall in SBP was 7.4%, significantly greater in those with lower rather than higher cognitive performance. A nocturnal drop in SBP of ≥10% was associated with lower cognitive performance in these elderly men. The limits to normal dipping appear to be shifted in the direction of a lesser drop in the very elderly. PMID:20428409

  8. Interfacial properties of acidified skim milk.

    PubMed

    Cases, E; Rampini, C; Cayot, Ph

    2005-02-01

    The purpose of this study is to investigate the tension properties and dilatational viscoelastic modulus of various skim milk proteins (whole milk, EDTA-treated milk, beta-casein, and beta-lactoglobulin) at an oil/water interface at 20 degrees C. Measurements are performed using a dynamic drop tensiometer for 15,000 s. The aqueous bulk phase is a skim milk simulated ultrafiltrate containing 11 x 10(-3) g L(-1) milk protein. At pH 6.7, beta-casein appears as the best to decrease the interfacial tension, whereas beta-lactoglobulin leads to the highest interfacial viscoelastic modulus value. Whole milk was almost as surface-active as individual beta-casein in terms of the final (steady-state) lowering of the interfacial tension, but the rate of tension lowering was smaller. EDTA treatment improved the rate of tension lowering of whole milk. The acidification of milk, from previous measurements, would lead to the enhancement of surface activity. At t=15,000 s, the order of effectiveness is pH 4.3 > pH 5.3 = pH 5.6 > pH 6.7 whole milk, suggesting that pH 4.3 whole milk is the best surface active. As compared to pH 6.7 whole milk, the use of pH 5.3 and pH 5.6 milk as surface active would result in the use of milk containing more free beta-casein born of pH-dissociated casein micelles.

  9. Alaskan frozen soil impact tests of the B83-C/S and Strategic Earth Penetrator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dockery, H.A.; Clarke, J.B.; Stull, S.P.

    To assess the penetrability of the B83 strategic bomb and a Strategic Earth Penetrator design into frozen soil and ice, Lawrence Livermore National Laboratory and Sandia National Laboratories, assisted by the US Air Force and US Army, conducted a series of tests in 1987. In April, Strategic Earth Penetrator units were dropped into multi-year sea ice and frozen tundra near Prudhoe Bay, Alaska. Calculated impact velocity ranged from 200 to 308 ft/s into ice and from 200 to 444 ft/s into frozen tundra. Tests in May include drops of a B83 design with specially designed ogive nose shape, a B83more » with a cap over the production ''cookie cutter'' nose, and a Strategic Earth Penetrator. The May tests were conducted near Fairbanks, Alaska, at Eielson Air Force Base and at Donnelly Flats on the Fort Greely Military Reservation. The type of frozen soil encountered at Eielson was very homogeneous in composition; however. Two drops impacted areas with very thin frozen soil layers at depths of about 24 in. below the surface. Velocities of these drops prior to impact ranged from 256 to 308 ft/s, and peak axial deceleration ranged from 160 to 490 g. The units penetrated to depths of 7.5-12 ft. Three other events impacted in a target area where frozen soil averaging 35 in. thick extended essentially to the surface. We calculated velocities prior to impact at 200-256 ft/s; and penetration depths of 3.2-9.6 ft. The geologic material at Donnelly Flats was primarily a very hard, rocky glacial deposit with a variable degree of ice bonding. Here, the test units dropped from 10,000 ft above ground level and achieved an average calculated velocity of 802 ft/s. Depth of penetration ranged from 7.6 to 13.5 ft.« less

  10. Restriction of neck flexion using soft cervical collars: a preliminary study

    PubMed Central

    Aker, Peter D; Randoll, Martine; Rheault, Chantal; O’Connor, Sandra

    1991-01-01

    This study investigates the use of dropped neck flexion as a manoeuvre to test the restrictive abilities of two different types of soft collars, an Airway soft cervical collar and a handmade cervical rough. The range of neck flexion of 40 asymptomatic subjects aged 20-29 was assessed, both with and without collar wear, using a Spinal Rangiometer. Dropped neck flexion is described as possibly being more representative of the type of movement that a patient with neck pain will undergo, and hence a more useful manoeuvre to employ when testing for the restrictive abilities of soft cervical collars. The mean dropped flexion was 64 degrees without collar wear, 58 degrees with the Airway soft collar, and 34 degrees with the cervical rough. Only the cervical rough provided both statistically (p < 0.001) and clinically (> 15°) significant restriction of dropped neck flexion. The comfort, preparation time, and ease of application of each of these collars is not addressed in this study, and may reflect on use in clinical practice. This preliminary study provides insight and pilot data for future studies in this area. ImagesFigure 2Figure 3

  11. Early signal of diverted use of tropicamide eye drops in France.

    PubMed

    Ponté, Camille; Pi, Christian; Palmaro, Aurore; Jouanjus, Emilie; Lapeyre-Mestre, Maryse

    2017-08-01

    Tropicamide is a mydriatic drug used as eye-drops for diagnostic or therapeutic purposes. From 2013, a diverted use by intravenous route has been suspected in Eastern Europe in opioids users. To date, no signal of misuse has been identified in France. The aims of this study were to investigate any early signals of a diverted use of tropicamide eye drops and to collect information regarding motives for the misuse and tropicamide-induced effects. Information was obtained at three levels: (1) at regional level (Midi-Pyrénées area), from reimbursement data and pharmacists' reports on suspicious requests; (2) at national level: from reimbursement data and prescriptions suggesting possible abuse from the OSIAP (Ordonnances Suspectes, Indicateur d'Abus Possible) survey; and (3) at international level: from VigiBase ® reports and Web sources. Beta-blocker eye-drops were used as comparators. In France, in 2014-2015, 17 (0.91%, 95% CI [0.53-1.46%]) falsified prescriptions involving tropicamide were identified in the OSIAP survey (compared with 0%, 95% CI [0-0.19%] for beta-blockers). Moreover, 37 other suspicious prescriptions were presented in 2015 (notified in 2016). In Midi-Pyrénées, seven patients aged 35-49 were reimbursed for 19-45 vials of 10 ml, in a year. Since September 2014, the regional Addictovigilance Centre has received 91 notifications of suspicious requests to obtain tropicamide. In VigiBase ® , two cases were identified but none in France. An increased interest in tropicamide-related Internet searches was observed from Russia and Ukraine. These results represent the first early warnings of a tropicamide diverted use in France. Tropicamide abusers would seek euphoria or hallucinations. The high doses involved in intravenous administration could lead to serious complications. © 2017 The British Pharmacological Society.

  12. Trends in 1029 Trauma Deaths at a Level 1 Trauma Center

    PubMed Central

    Oyeniyi, Blessing T.; Fox, Erin E.; Scerbo, Michelle; Tomasek, Jeffrey S.; Wade, Charles E.; Holcomb, John B.

    2016-01-01

    Background Over the last decade the age of trauma patients and injury mortality has increased. At the same time, many centers have implemented multiple interventions focused on improved hemorrhage control, effectively resulting in a bleeding control bundle of care. The objective of our study was to analyze the temporal distribution of trauma-related deaths, the factors that characterize that distribution and how those factors have changed over time at our urban level 1 trauma center. Methods Records at a urban Level 1 trauma center were reviewed. Two time periods (2005–2006 and 2012–2013) were included in the analysis. Mortality rates were directly adjusted for age, gender and mechanism of injury. The Mann-Whitney and chi square tests were used to compare variables between periods, with significance set at 0.05. Results 7080 patients (498 deaths) were examined in 2005–2006, while 8767 patients (531 deaths) were reviewed in 2012–2013. The median age increased 6 years, with a similar increase in those who died. In patients that died, no differences by gender, race or ethnicity were observed. Fall-related deaths are now the leading cause of death. Traumatic brain injury (TBI) and hemorrhage accounted for > 91% of all deaths. TBI (61%) and multiple organ failure or sepsis (6.2%) deaths were unchanged, while deaths associated with hemorrhage decreased from 36% to 25% (p<0.01). Across time periods, 26% of all deaths occurred within one hour of hospital arrival, while 59% occurred within 24 hours. Unadjusted mortality dropped from 7.0% to 6.1% (p=0.01) and in-hospital mortality dropped from 6.0% to 5.0% (p<0.01). Adjusted mortality dropped 24% from 7.6% (95% CI: 6.9–8.2) to 5.8% (95% CI: 5.3–6.3) and in-hospital mortality decreased 30% from 6.6% (95% CI: 6.0–7.2) to 4.7 (95% CI: 4.2–5.1). Conclusions Over the same time frame of this study, increases in trauma death across the globe have been reported. This single-site study demonstrated a significant reduction in mortality, likely attributable to decreased hemorrhagic death. It is possible that efforts focused on hemorrhage control interventions (a bleeding control bundle) resulted in this reduction. These changing factors provide guidance on future prevention and intervention efforts. PMID:27847192

  13. Studies on the stability of acrylamide in food during storage.

    PubMed

    Hoenicke, Katrin; Gatermann, Robert

    2005-01-01

    Acrylamide levels in a variety of food samples were analyzed before and after 3 months of storage at 10 degrees-12 degrees C. The analysis was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS) using deuterium-labeled acrylamide as internal standard. Acrylamide was stable in most matrixes (cookies, cornflakes, crispbread, raw sugar, potato crisps, peanuts) over time. However, slight decreases were determined for dietary biscuits (83-89%) and for licorice confection (82%). For coffee and cacao powder, a significant decrease occurred during storage for 3 or 6 months, respectively. Acrylamide concentrations dropped from 305 to 210 microg/kg in coffee and from 265 to 180 microg/kg in cacao powder. On the contrary, acrylamide remained stable in soluble coffee as well as in coffee substitutes. Reactions of acrylamide with SH group-containing substances were assumed as the cause for acrylamide degradation in coffee and cacao. Spiking experiments with acrylamide revealed that acrylamide concentrations remained stable in baby food, cola, and beer; however, recovery levels dropped in milk powder (71%), sulfurized apricot (53%), and cacao powder (17%). These observations suggest that variations in the acrylamide content of food, especially in coffee and cacao, can vary depending on the storage time because special food constituents and/or reaction products can affect the levels.

  14. Temperature-mediated absorption of phenylmercuric nitrate on polyethylene and polypropylene containers in chloramphenicol eye drops.

    PubMed

    Charoo, Naseem; Chiew, Magdalene; Tay, Amelia; Lian, Lai

    2014-09-01

    The aim of this work was to find the effect of temperature and manufacturing source of phenylmercuric nitrate (PMN) on PMN absorption on low-density polyethylene (LDPE) and polypropylene containers in chloramphenicol eye drops. Two factorial experiments were designed to study the effect of temperature on PMN assay in chloramphenicol eye drops stored in LDPE and prepared from two different PMN sources. PMN source had no effect on PMN assay at 2-8 °C, however at stress conditions (30 °C/75%RH) for 3 weeks, the effect of PMN source on PMN assay was found significant (p < 0.05) in formulations stored in LDPE bottles. Temperature was the major contributor to decreased PMN assay. In formulations stored in polypropylene containers, PMN source had significant effect on PMN assay at 2-8 °C and 30 °C/75%RH. Overall, new PMN and polypropylene bottles performed better. The eye drops complied with preservative efficacy test both initially and at the end of shelf life. The concentration exponent of PMN is very low and in spite of its high absorption by container/closure, PMN was still able to protect the eye drops at the end of shelf life. It can be inferred that preservative efficacy test is the better indicator of preservative activity.

  15. Design of an Experimental Facility for Passive Heat Removal in Advanced Nuclear Reactors

    NASA Astrophysics Data System (ADS)

    Bersano, Andrea

    With reference to innovative heat exchangers to be used in passive safety system of Gen- eration IV nuclear reactors and Small Modular Reactors it is necessary to study the natural circulation and the efficiency of heat removal systems. Especially in safety systems, as the decay heat removal system of many reactors, it is increasing the use of passive components in order to improve their availability and reliability during possible accidental scenarios, reducing the need of human intervention. Many of these systems are based on natural circulation, so they require an intense analysis due to the possible instability of the related phenomena. The aim of this thesis work is to build a scaled facility which can reproduce, in a simplified way, the decay heat removal system (DHR2) of the lead-cooled fast reactor ALFRED and, in particular, the bayonet heat exchanger, which transfers heat from lead to water. Given the thermal power to be removed, the natural circulation flow rate and the pressure drops will be studied both experimentally and numerically using the code RELAP5 3D. The first phase of preliminary analysis and project includes: the calculations to design the heat source and heat sink, the choice of materials and components and CAD drawings of the facility. After that, the numerical study is performed using the thermal-hydraulic code RELAP5 3D in order to simulate the behavior of the system. The purpose is to run pretest simulations of the facility to optimize the dimensioning setting the operative parameters (temperature, pressure, etc.) and to chose the most adequate measurement devices. The model of the system is continually developed to better simulate the system studied. High attention is dedicated to the control logic of the system to obtain acceptable results. The initial experimental tests phase consists in cold zero power tests of the facility in order to characterize and to calibrate the pressure drops. In future works the experimental results will be compared to the values predicted by the system code and differences will be discussed with the ultimate goal to qualify RELAP5-3D for the analysis of decay heat removal systems in natural circulation. The numerical data will be also used to understand the key parameters related to the heat transfer in natural circulation and to optimize the operation of the system.

  16. 10 CFR 32.101 - Schedule B-prototype tests for luminous safety devices for use in aircraft.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Schedule B-prototype tests for luminous safety devices for... thermometer. (d) Shock test. The device shall be dropped upon a concrete or iron surface in a 3-foot free gravitational fall, or shall be subjected to equivalent treatment in a test device simulating such a free fall...

  17. DRAGO (KIAA0247), a new DNA damage-responsive, p53-inducible gene that cooperates with p53 as oncosuppressor. [Corrected].

    PubMed

    Polato, Federica; Rusconi, Paolo; Zangrossi, Stefano; Morelli, Federica; Boeri, Mattia; Musi, Alberto; Marchini, Sergio; Castiglioni, Vittoria; Scanziani, Eugenio; Torri, Valter; Broggini, Massimo

    2014-04-01

    p53 influences genomic stability, apoptosis, autophagy, response to stress, and DNA damage. New p53-target genes could elucidate mechanisms through which p53 controls cell integrity and response to damage. DRAGO (drug-activated gene overexpressed, KIAA0247) was characterized by bioinformatics methods as well as by real-time polymerase chain reaction, chromatin immunoprecipitation and luciferase assays, time-lapse microscopy, and cell viability assays. Transgenic mice (94 p53(-/-) and 107 p53(+/-) mice on a C57BL/6J background) were used to assess DRAGO activity in vivo. Survival analyses were performed using Kaplan-Meier curves and the Mantel-Haenszel test. All statistical tests were two-sided. We identified DRAGO as a new p53-responsive gene induced upon treatment with DNA-damaging agents. DRAGO is highly conserved, and its ectopic overexpression resulted in growth suppression and cell death. DRAGO(-/-) mice are viable without macroscopic alterations. However, in p53(-/-) or p53(+/-) mice, the deletion of both DRAGO alleles statistically significantly accelerated tumor development and shortened lifespan compared with p53(-/-) or p53(+/-) mice bearing wild-type DRAGO alleles (p53(-/-), DRAGO(-/-) mice: hazard ratio [HR] = 3.25, 95% confidence interval [CI] = 1.7 to 6.1, P < .001; p53(+/-), DRAGO(-/-) mice: HR = 2.35, 95% CI = 1.3 to 4.0, P < .001; both groups compared with DRAGO(+/+) counterparts). DRAGO mRNA levels were statistically significantly reduced in advanced-stage, compared with early-stage, ovarian tumors, but no mutations were found in several human tumors. We show that DRAGO expression is regulated both at transcriptional-through p53 (and p73) and methylation-dependent control-and post-transcriptional levels by miRNAs. DRAGO represents a new p53-dependent gene highly regulated in human cells and whose expression cooperates with p53 in tumor suppressor functions.

  18. DRAGO (KIAA0247), a New DNA Damage–Responsive, p53-Inducible Gene That Cooperates With p53 as Oncosupprossor

    PubMed Central

    Polato, Federica; Rusconi, Paolo

    2014-01-01

    Background p53 influences genomic stability, apoptosis, autophagy, response to stress, and DNA damage. New p53-target genes could elucidate mechanisms through which p53 controls cell integrity and response to damage. Methods DRAGO (drug-activated gene overexpressed, KIAA0247) was characterized by bioinformatics methods as well as by real-time polymerase chain reaction, chromatin immunoprecipitation and luciferase assays, time-lapse microscopy, and cell viability assays. Transgenic mice (94 p53−/− and 107 p53+/− mice on a C57BL/6J background) were used to assess DRAGO activity in vivo. Survival analyses were performed using Kaplan–Meier curves and the Mantel–Haenszel test. All statistical tests were two-sided. Results We identified DRAGO as a new p53-responsive gene induced upon treatment with DNA-damaging agents. DRAGO is highly conserved, and its ectopic overexpression resulted in growth suppression and cell death. DRAGO−/− mice are viable without macroscopic alterations. However, in p53−/− or p53+/− mice, the deletion of both DRAGO alleles statistically significantly accelerated tumor development and shortened lifespan compared with p53−/− or p53+/− mice bearing wild-type DRAGO alleles (p53−/−, DRAGO−/− mice: hazard ratio [HR] = 3.25, 95% confidence interval [CI] = 1.7 to 6.1, P < .001; p53+/−, DRAGO−/− mice: HR = 2.35, 95% CI = 1.3 to 4.0, P < .001; both groups compared with DRAGO+/+ counterparts). DRAGO mRNA levels were statistically significantly reduced in advanced-stage, compared with early-stage, ovarian tumors, but no mutations were found in several human tumors. We show that DRAGO expression is regulated both at transcriptional—through p53 (and p73) and methylation-dependent control—and post-transcriptional levels by miRNAs. Conclusions DRAGO represents a new p53-dependent gene highly regulated in human cells and whose expression cooperates with p53 in tumor suppressor functions. PMID:24652652

  19. Transduction of Recombinant M3-p53-R12 Protein Enhances Human Leukemia Cell Apoptosis

    PubMed Central

    Lu, Tsung Chi; Zhao, Guan- Hao; Chen, Yao Yun; Chien, Chia-Ying; Huang, Chi-Hung; Lin, Kwang Hui; Chen, Shen Liang

    2016-01-01

    Tumor suppressor protein p53 plays important roles in initiating cell cycle arrest and promoting tumor cell apoptosis. Previous studies have shown that p53 is either mutated or defective in approximately 50% of human cancers; therefore restoring normal p53 activity in cancer cells might be an effective anticancer therapeutic approach. Herein, we designed a chimeric p53 protein flanked with the MyoD N-terminal transcriptional activation domain (amino acids 1-62, called M3) and a poly-arginine (R12) cell penetrating signal in its N-and C-termini respectively. This chimeric protein, M3-p53-R12, can be expressed in E. coli and purified using immobilized metal ion chromatography followed by serial refolding dialysis. The purified M3-p53-R12 protein retains DNA-binding activity and gains of cell penetrating ability. Using MTT assay, we demonstrated that M3-p53-R12 inhibited the growth of K562, Jurkat as well as HL-60 leukemia cells carrying mutant p53 genes. Results from FACS analysis also demonstrated that transduction of M3-p53-R12 protein induced cell cycle arrest of these leukemia cells. Of special note, M3-p53-R12 has no apoptotic effect on normal mesenchymal stem cells (MSC) and leukocytes, highlighting its differential effects on normal and tumor cells. To sum up, our results reveal that purified recombinant M3-p53-R12 protein has functions of suppressing the leukemia cell lines' proliferation and launching cell apoptosis, suggesting the feasibility of using M3-p53-R12 protein as an anticancer drug. In the future we will test whether this chimeric protein can preferentially trigger the death of malignant cancer cells without affecting normal cells in animals carrying endogenous or xenographic tumors. PMID:27390612

  20. Particle-size dependence of immersion freezing: Investigation of INUIT test aerosol particles with freely suspended water drops.

    NASA Astrophysics Data System (ADS)

    Diehl, Karoline; Debertshäuser, Michael; Eppers, Oliver; Jantsch, Evelyn; Mitra, Subir K.

    2014-05-01

    One goal of the research group INUIT (Ice Nuclei research UnIT) is to investigate the efficiencies of several test ice nuclei under comparable conditions but with different experimental techniques. In the present studies, two methods are used: the Mainz vertical wind tunnel and an acoustic levitator placed inside a cold chamber. In both cases drops are freely levitated, either at their terminal velocity in the wind tunnel updraft or around the nodes of a standing ultrasonic wave in the acoustic levitator. Thus, heat transfer conditions are well approximated, and wall contact effects on freezing as well as electrical charges of the drops are avoided. Drop radii are 370 μm and 1 mm, respectively. In the wind tunnel, drops are investigated at constant temperatures within a certain time period and the onset of freezing is observed directly. In the acoustic levitator, the drop temperature decreases during the experiments and is measured by an in-situ calibrated Infrared thermometer. The onset of freezing is indicated by a rapid rise of the drop surface temperature because of the release of latent heat. Investigated test ice nuclei are Snomax® as a proxy of biological particles and illite NX as well as K-feldspar as represents of mineral dust. The particle concentrations are 1 × 10-12 to 3 × 10-6 g Snomax® per drop and 5 × 10-9 to 5 × 10-5 g mineral dust per drop. Freezing temperatures are between -2 and -18° C in case of Snomax® and between -14 and -26° C in case of mineral dust. The lower the particle masses per drop the lower are the freezing temperatures. For similar particle concentrations in the drops, the median freezing temperatures determined by the two techniques agree well within the measurement errors. With the knowledge of the specific particle surface area of the mineral dusts, the results are interpreted also in terms of particle surface area per drop. Results from the wind tunnel experiments which are performed at constant temperatures indicate that the freezing times are shorter the lower the temperatures are. For evaluation and comparisons of the data, two models of heterogeneous freezing are applied, the stochastic and the time-independent singular description. The nucleation rate coefficients J(T) as well as the surface densities of active sites ns(T) or the numbers of active sites nm(T) are determined from the experimental data. It is shown that both models are suited to describe the present heterogeneous freezing results for the range of investigated particle masses or surface areas per drop. The comparison of the results from the two experimental techniques evaluated with the time-independent singular model indicates an excellent agreement within the measurement errors.

  1. Financial impact of reducing door-to-balloon time in ST-elevation myocardial infarction: a single hospital experience.

    PubMed

    Khot, Umesh N; Johnson-Wood, Michele L; Geddes, Jason B; Ramsey, Curtis; Khot, Monica B; Taillon, Heather; Todd, Randall; Shaikh, Saeed R; Berg, William J

    2009-07-26

    The impact of reducing door-to-balloon time on hospital revenues, costs, and net income is unknown. We prospectively determined the impact on hospital finances of (1) emergency department physician activation of the catheterization lab and (2) immediate transfer of the patient to an immediately available catheterization lab by an in-house transfer team consisting of an emergency department nurse, a critical care unit nurse, and a chest pain unit nurse. We collected financial data for 52 consecutive ST-elevation myocardial infarction patients undergoing emergency percutaneous intervention from October 1, 2004-August 31, 2005 and compared this group to 80 consecutive ST-elevation myocardial infarction patients from September 1, 2005-June 26, 2006 after protocol implementation. Per hospital admission, insurance payments (hospital revenue) decreased ($35,043 +/- $36,670 vs. $25,329 +/- $16,185, P = 0.039) along with total hospital costs ($28,082 +/- $31,453 vs. $18,195 +/- $9,242, P = 0.009). Hospital net income per admission was unchanged ($6962 vs. $7134, P = 0.95) as the drop in hospital revenue equaled the drop in costs. For every $1000 reduction in total hospital costs, insurance payments (hospital revenue) dropped $1077 for private payers and $1199 for Medicare/Medicaid. A decrease in hospital charges ($70,430 +/- $74,033 vs. $53,514 +/- $23,378, P = 0.059), diagnosis related group relative weight (3.7479 +/- 2.6731 vs. 2.9729 +/- 0.8545, P = 0.017) and outlier payments with hospital revenue>$100,000 (7.7% vs. 0%, P = 0.022) all contributed to decreasing ST-elevation myocardial infarction hospitalization revenue. One-year post-discharge financial follow-up revealed similar results: Insurance payments: $49,959 +/- $53,741 vs. $35,937 +/- $23,125, P = 0.044; Total hospital costs: $39,974 +/- $37,434 vs. $26,778 +/- $15,561, P = 0.007; Net Income: $9984 vs. $9159, P = 0.855. All of the financial benefits of reducing door-to-balloon time in ST-elevation myocardial infarction go to payers both during initial hospitalization and after one-year follow-up. ClinicalTrials.gov ID: NCT00800163.

  2. On the equilibrium contact angle of sessile liquid drops from molecular dynamics simulations.

    PubMed

    Ravipati, Srikanth; Aymard, Benjamin; Kalliadasis, Serafim; Galindo, Amparo

    2018-04-28

    We present a new methodology to estimate the contact angles of sessile drops from molecular simulations by using the Gaussian convolution method of Willard and Chandler [J. Phys. Chem. B 114, 1954-1958 (2010)] to calculate the coarse-grained density from atomic coordinates. The iso-density contour with average coarse-grained density value equal to half of the bulk liquid density is identified as the average liquid-vapor (LV) interface. Angles between the unit normal vectors to the average LV interface and unit normal vector to the solid surface, as a function of the distance normal to the solid surface, are calculated. The cosines of these angles are extrapolated to the three-phase contact line to estimate the sessile drop contact angle. The proposed methodology, which is relatively easy to implement, is systematically applied to three systems: (i) a Lennard-Jones (LJ) drop on a featureless LJ 9-3 surface; (ii) an SPC/E water drop on a featureless LJ 9-3 surface; and (iii) an SPC/E water drop on a graphite surface. The sessile drop contact angles estimated with our methodology for the first two systems are shown to be in good agreement with the angles predicted from Young's equation. The interfacial tensions required for this equation are computed by employing the test-area perturbation method for the corresponding planar interfaces. Our findings suggest that the widely adopted spherical-cap approximation should be used with caution, as it could take a long time for a sessile drop to relax to a spherical shape, of the order of 100 ns, especially for water molecules initiated in a lattice configuration on a solid surface. But even though a water drop can take a long time to reach the spherical shape, we find that the contact angle is well established much faster and the drop evolves toward the spherical shape following a constant-contact-angle relaxation dynamics. Making use of this observation, our methodology allows a good estimation of the sessile drop contact angle values even for moderate system sizes (with, e.g., 4000 molecules), without the need for long simulation times to reach the spherical shape.

  3. On the equilibrium contact angle of sessile liquid drops from molecular dynamics simulations

    NASA Astrophysics Data System (ADS)

    Ravipati, Srikanth; Aymard, Benjamin; Kalliadasis, Serafim; Galindo, Amparo

    2018-04-01

    We present a new methodology to estimate the contact angles of sessile drops from molecular simulations by using the Gaussian convolution method of Willard and Chandler [J. Phys. Chem. B 114, 1954-1958 (2010)] to calculate the coarse-grained density from atomic coordinates. The iso-density contour with average coarse-grained density value equal to half of the bulk liquid density is identified as the average liquid-vapor (LV) interface. Angles between the unit normal vectors to the average LV interface and unit normal vector to the solid surface, as a function of the distance normal to the solid surface, are calculated. The cosines of these angles are extrapolated to the three-phase contact line to estimate the sessile drop contact angle. The proposed methodology, which is relatively easy to implement, is systematically applied to three systems: (i) a Lennard-Jones (LJ) drop on a featureless LJ 9-3 surface; (ii) an SPC/E water drop on a featureless LJ 9-3 surface; and (iii) an SPC/E water drop on a graphite surface. The sessile drop contact angles estimated with our methodology for the first two systems are shown to be in good agreement with the angles predicted from Young's equation. The interfacial tensions required for this equation are computed by employing the test-area perturbation method for the corresponding planar interfaces. Our findings suggest that the widely adopted spherical-cap approximation should be used with caution, as it could take a long time for a sessile drop to relax to a spherical shape, of the order of 100 ns, especially for water molecules initiated in a lattice configuration on a solid surface. But even though a water drop can take a long time to reach the spherical shape, we find that the contact angle is well established much faster and the drop evolves toward the spherical shape following a constant-contact-angle relaxation dynamics. Making use of this observation, our methodology allows a good estimation of the sessile drop contact angle values even for moderate system sizes (with, e.g., 4000 molecules), without the need for long simulation times to reach the spherical shape.

  4. Taking the Easy Way Out: How the GED Testing Program Induces Students to Drop Out.

    PubMed

    Heckman, James J; Humphries, John Eric; Lafontaine, Paul A; Rodríguez, Pedro L

    2012-07-01

    The option to obtain a General Education Development (GED) certificate changes the incentives facing high school students. This paper evaluates the effect of three different GED policy innovations on high school graduation rates. A six point decrease in the GED pass rate due to an increase in passing standards produced a 1.3 point decline in overall dropout rates. The introduction of a GED certification program in high schools in Oregon produced a four percent decrease in graduation rates. Introduction of GED certificates in California increased dropout rates by 3 points. The GED program induces high school students to drop out.

  5. Taking the Easy Way Out: How the GED Testing Program Induces Students to Drop Out

    PubMed Central

    Heckman, James J.; Humphries, John Eric; LaFontaine, Paul A.; Rodríguez, Pedro L.

    2011-01-01

    The option to obtain a General Education Development (GED) certificate changes the incentives facing high school students. This paper evaluates the effect of three different GED policy innovations on high school graduation rates. A six point decrease in the GED pass rate due to an increase in passing standards produced a 1.3 point decline in overall dropout rates. The introduction of a GED certification program in high schools in Oregon produced a four percent decrease in graduation rates. Introduction of GED certificates in California increased dropout rates by 3 points. The GED program induces high school students to drop out. PMID:24634564

  6. 49 CFR 178.603 - Drop test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... drums, Plastic drums and Jerricans, Composite packagings which are in the shape of a drum Six—(three for... of natural wood, Plywood boxes, Reconstituted wood boxes, Fiberboard boxes, Plastic boxes, Steel or... Administrator. (c) Special preparation of test samples for the drop test. (1) Testing of plastic drums, plastic...

  7. Feasibility of granular bed filtration of an aerosol of ultrafine metallic particles including a pressure drop regeneration system.

    PubMed

    Bémer, D; Wingert, L; Morele, Y; Subra, I

    2015-09-01

    A process for filtering an aerosol of ultrafine metallic particles (UFP) has been designed and tested, based on the principle of a multistage granular bed. The filtration system comprised a succession of granular beds of varying thickness composed of glass beads of different diameters. This system allows the pressure drop to be regenerated during filtration ("on-line" mode) using a vibrating probe. Tests monitoring the pressure drop were conducted on a "10-L/min" low airflow rate device and on a "100-m(3)/hr" prototype. Granular bed unclogging is automated on the latter. The cyclic operation and filtration performances are similar to that of filter medium-based industrial dust collectors. Filtration of ultrafine metallic particles generated by different industrial processes such as arc welding, metal cutting, or spraying constitutes a difficult problem due to the high filter clogging properties of these particles and to the high temperatures generally encountered. Granular beds represent an advantageous means of filtering these aerosols with difficult properties.

  8. Development of graphite/copper composites utilizing engineered interfaces. M.S. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Devincent, Sandra M.

    1991-01-01

    In situ measurements of graphite/copper alloy contact angles were made using the sessile drop method. The interfacial energy values obtained from these measurements were then applied to a model for the fiber matrix interfacial debonding phenomenon found in graphite/copper composites. The formation obtained from the sessile drop tests led to the development of a copper alloy that suitably wets graphite. Characterization of graphite/copper alloy interfaces subjected to elevated temperatures was conducted using Scanning Electron Microscopy, Energy Dispersive Spectroscopy, Auger Electron Spectroscopy, and X Ray Diffraction analyses. These analyses indicated that during sessile drop tests conducted at 1130 C for 1 hour, copper alloys containing greater than 0.98 at pct chromium form continuous reaction layers of approx. 10 microns in thickness. The reaction layers are adherent to the graphite surface. The copper wets the reaction layer to form a contact angle of 60 deg or less. X ray diffraction results indicate that the reaction layer is Cr3C2.

  9. Condensation heat transfer and pressure drop of R-410A in flat aluminum multi-port tubes

    NASA Astrophysics Data System (ADS)

    Kim, Nae-Hyun

    2018-02-01

    Brazed heat exchangers with aluminum flat multi-port tubes are being used as condensers of residential air-conditioners. In this study, R-410A condensation tests were conducted in four multi-port tubes having a range of hydraulic diameter (0.78 ≤ Dh ≤ 0.95 mm). The test range covered the mass flux from 100 to 400 kg/m2 s and the heat flux at 3 kW/m2, which are typical operating conditions of residential air conditioners. Results showed that both the heat transfer coefficient and the pressure drop increased as the hydraulic diameter decreased. The effect of hydraulic diameter on condensation heat transfer was much larger than the predictions of existing correlations for the range of investigation. Comparison of the data with the correlations showed that some macro-channel tube correlations and mini-channel tube correlations reasonably predicted the heat transfer coefficient. However, macro-channel correlations highly overpredicted the pressure drop data.

  10. Biofuel production utilizing a dual-phase cultivation system with filamentous cyanobacteria.

    PubMed

    Aoki, Jinichi; Kawamata, Toru; Kodaka, Asuka; Minakawa, Masayuki; Imamura, Nobukazu; Tsuzuki, Mikio; Asayama, Munehiko

    2018-04-17

    Biomass yields and biofuel production were examined in a dual (solid and liquid)-phase cultivation system (DuPHA) with the unique filamentous cyanobacteria, Pseudanabaena sp. ABRG 5-3 and Limnothrix sp. SK1-2-1. Continuous circular cultivation was driven under the indoor closed (IC) or indoor opened (IO) conditions and provided biomass yields of approximately 8 to 27 g dry cell weight (DCW) floor m -2 d -1 . Alkanes of heptadecane (C 17 H 36 ) or pentadecane (C 15 H 32 ) as liquid biofuels were also recovered from the lower liquid-phase, in which cyanobacteria were dropped from the upper solid-phase and continuously cultivated with a small amount of medium. After the main cultivation in DuPHA, the upper solid-phase of a cotton cloth on which cyanobacteria grew was dried and directly subjected to a combustion test. This resulted in the thermal power (kJ s -1 ) of the cloth with microalgae increasing approximately 20 to 50% higher than that of the cloth only, suggesting a possibility of using the solid phase with microalgae as solid biofuel. Copyright © 2018. Published by Elsevier B.V.

  11. Comparison of stretch reflex responses evoked during drop jumping in highly skilled atheles versus untrained subjects.

    PubMed

    Judge, L W; Burke, J R

    2015-06-01

    The purpose of the study was to describe changes in the excitability of the stretch reflex response (SRR) during different drop jumps as a function of training background and as an adaptation to a preseason sport-specific resistance training program. Twelve collegiate field event athletes (discus, hammer, javelin, shot put, and weight; 9 males and 3 females) and 12 college-aged control subjects performed the following three jumps: (1) countermovement jump (CMJ); (2) countermovement drop jump; and (3) bounce-drop jump (BDJ). Neuromechanical changes in the performance of drop jumps by athletes were measured during the sport-specific resistance training program. Pre-post testing of drop jump performance by control subjects was included for comparison. For each jump trial, ground reaction forces (GRF), electromyograms (EMG) and cinematographic data were collected. There were no training adaptations. However, jump heights were greater for the athletes than the controls among the different jumps with the jump heights for all subjects being less during the BDJ than CMJ and CDJ. In athletes only, there was a differential modulation of the SRR from the gastrocnemius muscle with different levels of background muscle activity for the CDJ and BDJ. There were changes in excitability of SRR from the gastrocnemius muscle as a function of training background. Interrelated neuromechanical mechanisms to include landing biomechanics, intrinsic musculotendinous tissue properties of the ankle, and centrally regulated motor commands may underlie the facilitation of the SRR from the gastrocnemius muscle in athletes as compared to controls.

  12. 14 CFR 29.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 29.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  13. 14 CFR 27.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 27.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  14. 14 CFR 29.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 29.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  15. 14 CFR 27.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 27.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  16. 14 CFR 29.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 29.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  17. 14 CFR 27.501 - Ground loading conditions: landing gear with skids.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... exceed those obtained in a drop test of the gear with— (i) A drop height of 1.5 times that specified in § 27.725; and (ii) An assumed rotor lift of not more than 1.5 times that used in the limit drop tests...) The ground reactions rationally distributed along the bottom of the skid tube. (b) Vertical reactions...

  18. Sustained ocular delivery of brimonidine tartrate using ion activated in situ gelling system.

    PubMed

    Geethalakshmi, A; Karki, Roopa; Jha, Sajal Kumar; Venkatesh, D P; Nikunj, B

    2012-03-01

    The poor bioavailability and therapeutic response exhibited by conventional eye drops due to rapid precorneal elimination of the drug may be overcome by the use of an in situ gelling systems that are instilled as drops into the eye and undergo a sol-to-gel transition in the cul-de-sac which improves patient compliance as the dosage regimen is one drop of the dosage form twice a day. The loss of drug overcomes due to the immediate gel formation between the eye membrane and the drug being entrapped simultaneously in sol-gel transition in the cul de sac. The present work describes the formulation and evaluation of an ophthalmic delivery system of an antiglaucomal agent, brimonidine tartrate based on the concept of ion-activated in situ gelation. Gelrite was used as the gelling agent, which gels in the presence of mono or divalent cations present in the lacrimal fluid. The formulations were evaluated for clarity, pH measurement, gelling capacity, drug content estimation, rheological study, in-vitro diffusion study, antibacterial activity, isotonicity testing, eye irritation testing. In the developed formulations Gelrite Brimonidine-3 (GB3) exhibited sustained release of drug from formulation over a period of 8 hrs thus increasing residence time of the drug, non-irritating with no ocular damage or abnormal clinical signs to the cornea, iris or conjunctiva, stable and sterile. These results demonstrate that the developed system is an alternative to conventional ophthalmic drops, with better patient compliance, and is industrially oriented and economical.

  19. The role of intraoperative parathyroid hormone testing in patients with tertiary hyperparathyroidism after renal transplantation.

    PubMed

    Haustein, Silke V; Mack, Eberhard; Starling, James R; Chen, Herbert

    2005-12-01

    Intraoperative parathyroid hormone (PTH) testing has been shown to accurately define adequacy of parathyroid resection in patients with primary hyperparathyroidism (HPT) and alters the operative management in 10% to 15% of cases. However, the benefit of this technique in patients with tertiary HPT after renal transplantation undergoing parathyroidectomy is unclear. Intraoperative PTH was measured in 32 consecutive patients undergoing parathyroidectomy for tertiary HPT after renal transplantation between March 2001 and November 2004 by using the Elecsys assay at baseline and, subsequently, 5, 10, and 15 minutes after curative resection. The outcomes of these patients were evaluated. All patients were cured after surgery. Of the 32 patients, 29 were found to have parathyroid hyperplasia, while 1 had a single adenoma and 2 had double adenomas. The average drop in intraoperative PTH levels after curative resection was 69 +/- 3.5% at 5 min., 77 +/- 2.3% at 10 minutes, and 83 +/- 3.4% at 15 minutes. PTH testing changed the intraoperative management in 5 (16%) patients. One patient with a single adenoma and 2 patients with double adenomas had a >50% drop at 10 minutes. after excision; therefore, the operation was terminated without further resection. Two patients did not have a >50% drop at 10 minutes after 3.5 gland resection. These patients were explored further, and additional supernumerary parathyroid glands were identified and resected. After resection of these additional glands, the PTH fell by >50%, indicating cure. In patients undergoing parathyroidectomy for tertiary HPT after renal transplantation, a decrease in intraoperative PTH levels >50% at 10 minutes after completion of the operation indicated adequate resection. Furthermore, intraoperative PTH testing altered the operative management in 16% of patients. Therefore, similar to its role in patients with primary HPT, intraoperative PTH testing appears to play an equally important role in the management of patients with tertiary HPT undergoing parathyroidectomy.

  20. The Reliability of Microalloyed Sn-Ag-Cu Solder Interconnections Under Cyclic Thermal and Mechanical Shock Loading

    NASA Astrophysics Data System (ADS)

    Mattila, Toni T.; Hokka, Jussi; Paulasto-Kröckel, Mervi

    2014-11-01

    In this study, the performance of three microalloyed Sn-Ag-Cu solder interconnection compositions (Sn-3.1Ag-0.52Cu, Sn-3.0Ag-0.52Cu-0.24Bi, and Sn-1.1Ag-0.52Cu-0.1Ni) was compared under mechanical shock loading (JESD22-B111 standard) and cyclic thermal loading (40 ± 125°C, 42 min cycle) conditions. In the drop tests, the component boards with the low-silver nickel-containing composition (Sn-Ag-Cu-Ni) showed the highest average number of drops-to-failure, while those with the bismuth-containing alloy (Sn-Ag-Cu-Bi) showed the lowest. Results of the thermal cycling tests showed that boards with Sn-Ag-Cu-Bi interconnections performed the best, while those with Sn-Ag-Cu-Ni performed the worst. Sn-Ag-Cu was placed in the middle in both tests. In this paper, we demonstrate that solder strength is an essential reliability factor and that higher strength can be beneficial for thermal cycling reliability but detrimental to drop reliability. We discuss these findings from the perspective of the microstructures and mechanical properties of the three solder interconnection compositions and, based on a comprehensive literature review, investigate how the differences in the solder compositions influence the mechanical properties of the interconnections and discuss how the differences are reflected in the failure mechanisms under both loading conditions.

  1. Employment Shifts in the TAFE Workforce in Victoria, 1993-98. Working Paper.

    ERIC Educational Resources Information Center

    Shah, Chandra

    Data on the work force in Technical and Further Education (TAFE) institutes in Victoria, Australia, for 1993-1998 reveal a number of structural changes. First, the number of women staff increased from 46% to 53%, although men still constitute 54% of the teaching staff. As full-time staff employment dropped an average of 1.1% annually, part-time…

  2. DIME Students Witness Test Drop

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Students watch a test run on their experiment before the actual drop. They designed and built their apparatus to fit within a NASA-provided drop structure. This was part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  3. Effects of in-season low-volume high-intensity plyometric training on explosive actions and endurance of young soccer players.

    PubMed

    Ramírez-Campillo, Rodrigo; Meylan, César; Alvarez, Cristian; Henríquez-Olguín, Carlos; Martínez, Cristian; Cañas-Jamett, Rodrigo; Andrade, David C; Izquierdo, Mikel

    2014-05-01

    Integrating specific training methods to improve explosive actions and endurance in youth soccer is an essential part of players' development. This study investigated the efficiency of short-term vertical plyometric training program within soccer practice to improve both explosive actions and endurance in young soccer players. Seventy-six players were recruited and assigned either to a training group (TG; n = 38; 13.2 ± 1.8 years) or a control group (CG; n = 38; 13.2 ± 1.8 years) group. All players trained twice per week, but the TG followed a 7-week plyometric program implemented within soccer practice, whereas the CG followed regular practice. Twenty-meter sprint time (20-m), Illinois agility test time, countermovement jump (CMJ) height, 20- (RSI20) and 40- (RSI40) cm drop jump reactive strength index, multiple 5 bounds distance (MB5), maximal kicking test for distance (MKD), and 2.4-km time trial were measured before and after the 7-week period. Plyometric training induced significant (p ≤ 0.05) and small to moderate standardized effect (SE) improvement in the CMJ (4.3%; SE = 0.20), RSI20 (22%; SE = 0.57), RSI40 (16%; SE = 0.37), MB5 (4.1%; SE = 0.28), Illinois agility test time (-3.5%, SE = -0.26), MKD (14%; SE = 0.53), 2.4-km time trial (-1.9%; SE = -0.27) performances but had a trivial and nonsignificant effect on 20-m sprint time (-0.4%; SE = -0.03). No significant improvements were found in the CG. An integrated vertical plyometric program within the regular soccer practice can substitute soccer drills to improve most explosive actions and endurance, but horizontal exercises should also be included to enhance sprinting performance.

  4. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase II Accelerated Free-Fall

    DTIC Science & Technology

    2016-04-30

    support contractor , Infoscitex, conducted a series of tests to identify the performance capabilities of the Vertical Impact Device (VID). The VID is a...C. Table 3. AFD Evaluation with Red IMPAC Programmer: Data Summary Showing Means and Standard Deviations Test Cell Drop Ht . (in) Mean Peak

  5. Empirical Green's function analysis: Taking the next step

    USGS Publications Warehouse

    Hough, S.E.

    1997-01-01

    An extension of the empirical Green's function (EGF) method is presented that involves determination of source parameters using standard EGF deconvolution, followed by inversion for a common attenuation parameter for a set of colocated events. Recordings of three or more colocated events can thus be used to constrain a single path attenuation estimate. I apply this method to recordings from the 1995-1996 Ridgecrest, California, earthquake sequence; I analyze four clusters consisting of 13 total events with magnitudes between 2.6 and 4.9. I first obtain corner frequencies, which are used to infer Brune stress drop estimates. I obtain stress drop values of 0.3-53 MPa (with all but one between 0.3 and 11 MPa), with no resolved increase of stress drop with moment. With the corner frequencies constrained, the inferred attenuation parameters are very consistent; they imply an average shear wave quality factor of approximately 20-25 for alluvial sediments within the Indian Wells Valley. Although the resultant spectral fitting (using corner frequency and ??) is good, the residuals are consistent among the clusters analyzed. Their spectral shape is similar to the the theoretical one-dimensional response of a layered low-velocity structure in the valley (an absolute site response cannot be determined by this method, because of an ambiguity between absolute response and source spectral amplitudes). I show that even this subtle site response can significantly bias estimates of corner frequency and ??, if it is ignored in an inversion for only source and path effects. The multiple-EGF method presented in this paper is analogous to a joint inversion for source, path, and site effects; the use of colocated sets of earthquakes appears to offer significant advantages in improving resolution of all three estimates, especially if data are from a single site or sites with similar site response.

  6. Containerless processing of undercooled melts

    NASA Technical Reports Server (NTRS)

    Shong, D. S.; Graves, J. A.; Ujiie, Y.; Perepezko, J. H.

    1987-01-01

    Containerless drop tube processing allows for significant levels of liquid undercooling through control of parameters such as sample size, surface coating and cooling rate. A laboratory scale (3 m) drop tube has been developed which allows the undercooling and solidification behavior of powder samples to be evaluated under low gravity free-fall conditions. The level of undercooling obtained in an InSb-Sb eutectic alloy has been evaluated by comparing the eutectic spacing in drop tube samples with a spacing/undercooling relationship established using thermal analysis techniques. Undercoolings of 0.17 and 0.23 T(e) were produced by processing under vacuum and He gas conditions respectively. Alternatively, the formation of an amorphous phase in a Ni-Nb eutectic alloy indicates that undercooling levels of approximately 500 C were obtained by drop tube processing. The influence of droplet size and gas environment on undercooling behavior in the Ni-Nb eutectic was evaluated through their effect on the amorphous/crystalline phase ratio. To supplement the structural analysis, heat flow modeling has been developed to describe the undercooling history during drop tube processing, and the model has been tested experimentally.

  7. Modified Drop Tower Impact Tests for American Football Helmets.

    PubMed

    Rush, G Alston; Prabhu, R; Rush, Gus A; Williams, Lakiesha N; Horstemeyer, M F

    2017-02-19

    A modified National Operating Committee on Standards for Athletic Equipment (NOCSAE) test method for American football helmet drop impact test standards is presented that would provide better assessment of a helmet's on-field impact performance by including a faceguard on the helmet. In this study, a merger of faceguard and helmet test standards is proposed. The need for a more robust systematic approach to football helmet testing procedures is emphasized by comparing representative results of the Head Injury Criterion (HIC), Severity Index (SI), and peak acceleration values for different helmets at different helmet locations under modified NOCSAE standard drop tower tests. Essentially, these comparative drop test results revealed that the faceguard adds a stiffening kinematic constraint to the shell that lessens total energy absorption. The current NOCSAE standard test methods can be improved to represent on-field helmet hits by attaching the faceguards to helmets and by including two new helmet impact locations (Front Top and Front Top Boss). The reported football helmet test method gives a more accurate representation of a helmet's performance and its ability to mitigate on-field impacts while promoting safer football helmets.

  8. Rad53 regulates replication fork restart after DNA damage in Saccharomyces cerevisiae

    PubMed Central

    Szyjka, Shawn J.; Aparicio, Jennifer G.; Viggiani, Christopher J.; Knott, Simon; Xu, Weihong; Tavaré, Simon; Aparicio, Oscar M.

    2008-01-01

    Replication fork stalling at a DNA lesion generates a damage signal that activates the Rad53 kinase, which plays a vital role in survival by stabilizing stalled replication forks. However, evidence that Rad53 directly modulates the activity of replication forks has been lacking, and the nature of fork stabilization has remained unclear. Recently, cells lacking the Psy2–Pph3 phosphatase were shown to be defective in dephosphorylation of Rad53 as well as replication fork restart after DNA damage, suggesting a mechanistic link between Rad53 deactivation and fork restart. To test this possibility we examined the progression of replication forks in methyl-methanesulfonate (MMS)-damaged cells, under different conditions of Rad53 activity. Hyperactivity of Rad53 in pph3Δ cells slows fork progression in MMS, whereas deactivation of Rad53, through expression of dominant-negative Rad53-KD, is sufficient to allow fork restart during recovery. Furthermore, combined deletion of PPH3 and PTC2, a second, unrelated Rad53 phosphatase, results in complete replication fork arrest and lethality in MMS, demonstrating that Rad53 deactivation is a key mechanism controlling fork restart. We propose a model for regulation of replication fork progression through damaged DNA involving a cycle of Rad53 activation and deactivation that coordinates replication restart with DNA repair. PMID:18628397

  9. Colony, hanging drop, and methylcellulose three dimensional hypoxic growth optimization of renal cell carcinoma cell lines.

    PubMed

    Matak, Damian; Brodaczewska, Klaudia K; Lipiec, Monika; Szymanski, Łukasz; Szczylik, Cezary; Czarnecka, Anna M

    2017-08-01

    Renal cell carcinoma (RCC) is the most lethal of the common urologic malignancies, comprising 3% of all human neoplasms, and the incidence of kidney cancer is rising annually. We need new approaches to target tumor cells that are resistant to current therapies and that give rise to recurrence and treatment failure. In this study, we focused on low oxygen tension and three-dimensional (3D) cell culture incorporation to develop a new RCC growth model. We used the hanging drop and colony formation methods, which are common in 3D culture, as well as a unique methylcellulose (MC) method. For the experiments, we used human primary RCC cell lines, metastatic RCC cell lines, human kidney cancer stem cells, and human healthy epithelial cells. In the hanging drop assay, we verified the potential of various cell lines to create solid aggregates in hypoxic and normoxic conditions. With the semi-soft agar method, we also determined the ability of various cell lines to create colonies under different oxygen conditions. Different cell behavior observed in the MC method versus the hanging drop and colony formation assays suggests that these three assays may be useful to test various cell properties. However, MC seems to be a particularly valuable alternative for 3D cell culture, as its higher efficiency of aggregate formation and serum independency are of interest in different areas of cancer biology.

  10. Interaction of a liquid jet with an oncoming gas stream

    NASA Astrophysics Data System (ADS)

    Koval', M. A.; Shvets, A. I.

    1987-06-01

    Wind-tunnel tests were carried out to study the interaction between water jets issuing from various types of nozzles (including cylindrical) and subsonic and supersonic air streams with Mach numbers from 0.3 to 3 and Reynolds numbers from 1 x 10 to the 6th to 3 x 10 to the 7th. The following interaction structure was observed: (1) at moderate outflow velocities, the liquid jet has an extended region, which subsequently expands abruptly as a spherical or mushroom-shaped drop; (2) this drop is atomized in the peripheral region and is carried away as a gas-liquid mixture; (3) a shock wave is formed in front of the jet in the oncoming supersonic stream; and (4) a separated flow region is present in the vicinity of the cylindrical nozzle section.

  11. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    PubMed

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no preference regarding the two implant systems evaluated. Three operators preferred GENESIS implants, two had no preference and one preferred GENESIS in medium and soft bone and PRIMA in hard bone. No statistically significant differences were observed between the systems' implant types, although four GENESIS implants failed versus none of the PRIMA type. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two implant designs. Conflict-of-interest statement: This research project was originally funded by Keystone Italia, Dental spa (Verona, Italy), the manufacturer of the implants evaluated in this investigation. 
 
However, when Keystone Italia received the data of the present manuscript, they refused to honour the financial agreement for the present publication. Therefore, no further follow-ups of this trial will be considered. A legal action was initiated against Keystone Italia. The data belonged to the authors and by no means was the manufacturer allowed to interfere with the conduct of the trial or the publication of the results.

  12. Managing Challenges in a Multi Contractor Project

    NASA Technical Reports Server (NTRS)

    King, Ron

    2011-01-01

    The presentation provides a project description, describes the integrated product team, and review project challenges. The challenges include programmatic, technical, basic drop tests, heavy drop tests, C-17 envelope expansion, and Ares I-X.

  13. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  14. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  15. 14 CFR 31.27 - Strength.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... drop test height of 36 inches, or a drop test height that produces, upon impact, a velocity equal to the maximum vertical velocity determined in accordance with § 31.19, whichever is higher, must be used...

  16. Experimental and Computational Analysis of Unidirectional Flow Through Stirling Engine Heater Head

    NASA Technical Reports Server (NTRS)

    Wilson, Scott D.; Dyson, Rodger W.; Tew, Roy C.; Demko, Rikako

    2006-01-01

    A high efficiency Stirling Radioisotope Generator (SRG) is being developed for possible use in long-duration space science missions. NASA s advanced technology goals for next generation Stirling convertors include increasing the Carnot efficiency and percent of Carnot efficiency. To help achieve these goals, a multi-dimensional Computational Fluid Dynamics (CFD) code is being developed to numerically model unsteady fluid flow and heat transfer phenomena of the oscillating working gas inside Stirling convertors. In the absence of transient pressure drop data for the zero mean oscillating multi-dimensional flows present in the Technology Demonstration Convertors on test at NASA Glenn Research Center, unidirectional flow pressure drop test data is used to compare against 2D and 3D computational solutions. This study focuses on tracking pressure drop and mass flow rate data for unidirectional flow though a Stirling heater head using a commercial CFD code (CFD-ACE). The commercial CFD code uses a porous-media model which is dependent on permeability and the inertial coefficient present in the linear and nonlinear terms of the Darcy-Forchheimer equation. Permeability and inertial coefficient were calculated from unidirectional flow test data. CFD simulations of the unidirectional flow test were validated using the porous-media model input parameters which increased simulation accuracy by 14 percent on average.

  17. 40 CFR 53.60 - General provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... samplers are subject to the additional tests and performance requirements specified in § 53.62 (full wind... shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it meets all requirements of § 53.63 (wind tunnel inlet aspiration test), § 53.65 (loading test), and § 53.66 (volatility...

  18. 40 CFR 53.60 - General provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... samplers are subject to the additional tests and performance requirements specified in § 53.62 (full wind... shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it meets all requirements of § 53.63 (wind tunnel inlet aspiration test), § 53.65 (loading test), and § 53.66 (volatility...

  19. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    PubMed

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  20. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests

    PubMed Central

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2014-01-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%). PMID:27134543

  1. Different behavioural responses of larval fish under microgravity and morphological correlates in the inner ear -a drop-tower study

    NASA Astrophysics Data System (ADS)

    Hilbig, Reinhard; Weigele, Jochen; Knie, Miriam; Hendrik Anken, Ralf

    In vertebrates altered gravitational environments such as weightlessness (microgravity, g) in-duce changes in central and peripheral interpretation of sensory input leading to alterations in motor behaviour (e.g., intersensory-conflicts) including space motion sickness, a sensory motor kinetosis normally accompanied by malaise and vomiting. In fish it had been repeatedly shown that some fish of a given batch reveal motion sickness after transition from hypergravity (pull up) to microgravity microgravity in the course of parabolic aircraft flight (PF= low quality microgravity = LQM) experiments or in the case of drop tower experiments at ZARM (Bre-men) immediately after release of the capsule. The drop-tower studies were designed to further elucidate the role of otolith asymmetry concerning an individually different susceptibility to kinetoses. In order to test, whether the differing results between the PF and the drop-tower experiment were based exclusively on the differing quality of diminished gravity, or, if further parameters of the PF and the drop-tower environment need to be taken into consideration (e.g., vibrations and changing accelerations during PFs or the brisk compression of the drop-capsule at its release) to explain the differing results, drop-tower flights were performed at a series of increasing accelerations, by centrifugation in the drop capsule. This simulation of "differ-ent micro" gravity was carried out in housing larval cichlid fish (Oreochromis mossambicus) within a centrifuge at high quality microgravity 10-6g (HQM) and 10-4g to 0.3g during the drop-tower flights. The percentual ratios of the swimming behaviour at drop-tower changed significantly according to the increasing acceleration force of the centrifuge during flight. With increasing acceleration (= detectable gravity for fish) the relative proportion of looping an d spinning movements decreased in favour of normal swimming an at 0.3g nearly no kinetotic behaviour was observed. When during centrifugation in the drop-tower capsule LQM ranged between those of PF LQM the fish displayed comparable types of behaviour (normal and kine-totic swimming). This indicates that some normally swimming fish during PFs and drop-tower LQM use the residual gravity as a cue for orientation. Whereas kinetoses were exhibited by some 90 The present findings on otolith asymmetry support the concept, according to which kinetosis susceptibility is based on highly asymmetric inner ear stones.

  2. 49 CFR 178.33b-7 - Design qualification test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., each new design must be drop tested as follows: Three groups of twenty-five filled containers must be... 49 Transportation 2 2010-10-01 2010-10-01 false Design qualification test. 178.33b-7 Section 178... PACKAGINGS Specifications for Inside Containers, and Linings § 178.33b-7 Design qualification test. (a) Drop...

  3. 46 CFR 160.056-4 - Approval tests of prototype rescue boat.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Approval tests of prototype rescue boat. 160.056-4..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Rescue Boat § 160.056-4 Approval tests of prototype rescue boat. (a) Drop test. The rescue boat, fully equipped, shall be dropped, in a...

  4. 46 CFR 160.056-4 - Approval tests of prototype rescue boat.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Approval tests of prototype rescue boat. 160.056-4..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Rescue Boat § 160.056-4 Approval tests of prototype rescue boat. (a) Drop test. The rescue boat, fully equipped, shall be dropped, in a...

  5. 46 CFR 160.056-4 - Approval tests of prototype rescue boat.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Approval tests of prototype rescue boat. 160.056-4..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Rescue Boat § 160.056-4 Approval tests of prototype rescue boat. (a) Drop test. The rescue boat, fully equipped, shall be dropped, in a...

  6. 46 CFR 160.056-4 - Approval tests of prototype rescue boat.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Approval tests of prototype rescue boat. 160.056-4..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Rescue Boat § 160.056-4 Approval tests of prototype rescue boat. (a) Drop test. The rescue boat, fully equipped, shall be dropped, in a...

  7. 46 CFR 160.056-4 - Approval tests of prototype rescue boat.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Approval tests of prototype rescue boat. 160.056-4 Section 160.056-4 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT... tests of prototype rescue boat. (a) Drop test. The rescue boat, fully equipped, shall be dropped, in a...

  8. Dustiness behaviour of loose and compacted Bentonite and organoclay powders: What is the difference in exposure risk?

    NASA Astrophysics Data System (ADS)

    Jensen, Keld Alstrup; Koponen, Ismo Kalevi; Clausen, Per Axel; Schneider, Thomas

    2009-01-01

    Single-drop and rotating drum dustiness testing was used to investigate the dustiness of loose and compacted montmorillonite (Bentonite) and an organoclay (Nanofil®5), which had been modified from montmorillonite-rich Bentonite. The dustiness was analysed based on filter measurements as well as particle size distributions, the particle generation rate, and the total number of generated particles. Particle monitoring was completed using a TSI Fast Mobility Particle Sizer (FMPS) and a TSI Aerosol Particle Sizer (APS) at 1 s resolution. Low-pressure uniaxial powder compaction of the starting materials showed a logarithmic compaction curve and samples subjected to 3.5 kg/cm2 were used for dustiness testing to evaluate the role of powder compaction, which could occur in powders from large shipments or high-volume storage facilities. The dustiness tests showed intermediate dustiness indices (1,077-2,077 mg/kg powder) in tests of Nanofil®5, Bentonite, and compacted Bentonite, while a high-level dustiness index was found for compacted Nanofil®5 (3,487 mg/kg powder). All powders produced multimodal particle size-distributions in the dust cloud with one mode around 300 nm (Bentonite) or 400 nm (Nanofil®5) as well as one (Nanofil®5) or two modes (Bentonite) with peaks between 1 and 2.5 μm. The dust release was found to occur either as a burst (loose Bentonite and Nanofil®5), constant rate (compacted Nanofil®5), or slowly increasing rate (compacted Bentonite). In rotating drum experiments, the number of particles generated in the FMPS and APS size-ranges were in general agreement with the mass-based dustiness index, but the same order was not observed in the single-drop tests. Compaction of Bentonite reduced the number of generated particles with app. 70 and 40% during single-drop and rotating drum dustiness tests, respectively. Compaction of Nanofil®5 reduced the dustiness in the single-drop test, but it was more than doubled in the rotating drum test. Physically relevant low-pressure compaction may reduce the risk of particle exposure if powders are handled in operations with few agitations such as pouring or tapping. Repeated agitation, e.g., mixing, of these compacted powders, would result in reduced (app. 20% for Bentonite) or highly increased (app. 225% for Nanofil®5) dustiness and thereby alter the exposure risk significantly.

  9. The conversion of a room temperature NaK loop to a high temperature MHD facility for Li/V blanket testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, C.B.; Haglund, R.C.; Miller, M.E.

    1996-12-31

    The Vanadium/Lithium system has been the recent focus of ANL`s Blanket Technology Pro-ram, and for the last several years, ANL`s Liquid Metal Blanket activities have been carried out in direct support of the ITER (International Thermonuclear Experimental Reactor) breeding blanket task area. A key feasibility issue for the ITER Vanadium/Lithium breeding blanket is the Near the development of insulator coatings. Design calculations, Hua and Gohar, show that an electrically insulating layer is necessary to maintain an acceptably low magneto-hydrodynamic (MHD) pressure drop in the current ITER design. Consequently, the decision was made to convert Argonne`s Liquid Metal EXperiment (ALEX) frommore » a 200{degrees}C NaK facility to a 350{degrees}C lithium facility. The upgraded facility was designed to produce MHD pressure drop data, test section voltage distributions, and heat transfer data for mid-scale test sections and blanket mockups at Hartmann numbers (M) and interaction parameters (N) in the range of 10{sup 3} to 10{sup 5} in lithium at 350{degrees}C. Following completion of the upgrade work, a short performance test was conducted, followed by two longer multiple-hour, MHD tests, all at 230{degrees}C. The modified ALEX facility performed up to expectations in the testing. MHD pressure drop and test section voltage distributions were collected at Hartmann numbers of 1000.« less

  10. Conversion of a room temperature NaK loop to a high temperature MHD facility for Li/V blanket testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, C.B.; Haglund, R.C.; Miller, M.E.

    1996-12-31

    The Vanadium/Lithium system has been the recent focus of ANL`s Blanket Technology Program, and for the last several years, ANL`s Liquid Metal Blanket activities have been carried out in direct support of the ITER (International Thermonuclear Experimental Reactor) breeding blanket task area. A key feasibility issue for the ITER Vanadium/Lithium breeding blanket is the development of insulator coatings. Design calculations, Hua and Gohar, show that an electrically insulating layer is necessary to maintain an acceptably low magnetohydrodynamic (MHD) pressure drop in the current ITER design. Consequently, the decision was made to convert Argonne`s Liquid Metal EXperiment (ALEX) from a 200{degree}Cmore » NaK facility to a 350{degree}C lithium facility. The upgraded facility was designed to produce MHD pressure drop data, test section voltage distributions, and heat transfer data for mid-scale test sections and blanket mockups at Hartmann numbers (M) and interaction parameters (N) in the range of 10{sup 3} to 10{sup 5} in lithium at 350{degree}C. Following completion of the upgrade work, a short performance test was conducted, followed by two longer, multiple-hour, MHD tests, all at 230{degree}C. The modified ALEX facility performed up to expectations in the testing. MHD pressure drop and test section voltage distributions were collected at Hartmann numbers of 1000. 4 refs., 2 figs.« less

  11. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 2: Data from seat testing

    NASA Technical Reports Server (NTRS)

    Shane, S. J.

    1985-01-01

    The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.

  12. 49 CFR 178.603 - Drop test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the fourth sample). Fifth drop: On a corner (using the fifth sample). Bags—single-ply with a side seam...). Bags—single-ply without a side seam, or multi-ply Three—(two drops per bag) First drop: Flat on a wide...) For a bag, neither the outermost ply nor an outer packaging exhibits any damage likely to adversely...

  13. [Predicting drop-out during the systems training for emotional predictability and problem solving (STEPPS)].

    PubMed

    van Diepen, J B; de Groot, I W

    2016-01-01

    Drop-out is a complex problem in mental health care and in STEPPS. Research has revealed a variety of predicting factors and has produced contradictory results. To investigate whether the information available at the start of STEPPS can pinpoint predictors of drop-out. The ROM data for 150 patients were used to test the link between the following factors: age, gender, education, employment, substance abuse, anxiety, hostility, interpersonal relations, responsibility and social concordance with drop-out. The method used for testing was logistic regression analysis. Factors that contributed significantly to the prediction of drop-out were gender and employment status. These factors made up 16% of the explained variation (R2 Nagelkerkes) in drop-out. Gender was the strongest predictive factor. Concerning the other factors, no differences were found between groups (drop-out and non-dropouts). In its present form STEPPS does not suit a large number of the male participants. Drop-out during STEPPS is hard to predict on the basis of ROM-questionnaires. Future research should focus on preconditions and marginal conditions that influence patients to complete their training.

  14. The Role of Siah1-Induced Degradation of beta-Catenin in Androgen Receptor Signaling

    DTIC Science & Technology

    2007-11-01

    biological responses to DNA damage: Insights from yeast and p53. Nat. Cell Biol. 3, E277–E286. Winston, J.T., Strack, P., Beer -Romero, P., Chu, C.Y...apoptosis, depending on the cell line tested [3]. The findings suggest that p53-mediated induction of Siah1 expression could play an important role in the...hypothesis that Siah1 is an important mediator of p53’s effects in prostate cancers. If the hypothesis proves to be correct, then the results derived

  15. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    PubMed

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  16. On-sun testing of an advanced falling particle receiver system

    NASA Astrophysics Data System (ADS)

    Ho, Clifford K.; Christian, Joshua M.; Yellowhair, Julius; Siegel, Nathan; Jeter, Sheldon; Golob, Matthew; Abdel-Khalik, Said I.; Nguyen, Clayton; Al-Ansary, Hany

    2016-05-01

    A 1 MWth high-temperature falling particle receiver was constructed and tested at the National Solar Thermal Test Facility at Sandia National Laboratories. The continuously recirculating system included a particle elevator, top and bottom hoppers, and a cavity receiver that comprised a staggered array of porous chevron-shaped mesh structures that slowed the particle flow through the concentrated solar flux. Initial tests were performed with a peak irradiance of ~300 kW/m2 and a particle mass flow rate of 3.3 kg/s. Peak particle temperatures reached over 700 °C near the center of the receiver, but the particle temperature increase near the sides was lower due to a non-uniform irradiance distribution. At a particle inlet temperature of ~440 °C, the particle temperature increase was 27 °C per meter of drop length, and the thermal efficiency was ~60% for an average irradiance of 110 kW/m2. At an average irradiance of 211 kW/m2, the particle temperature increase was 57.1 °C per meter of drop length, and the thermal efficiency was ~65%. Tests with higher irradiances are being performed and are expected to yield greater particle temperature increases and efficiencies.

  17. Carbon dioxide capture from atmospheric air using sodium hydroxide spray.

    PubMed

    Stolaroff, Joshuah K; Keith, David W; Lowry, Gregory V

    2008-04-15

    In contrast to conventional carbon capture systems for power plants and other large point sources, the system described in this paper captures CO2 directly from ambient air. This has the advantages that emissions from diffuse sources and past emissions may be captured. The objective of this research is to determine the feasibility of a NaOH spray-based contactor for use in an air capture system by estimating the cost and energy requirements per unit CO2 captured. A prototype system is constructed and tested to measure CO2 absorption, energy use, and evaporative water loss and compared with theoretical predictions. A numerical model of drop collision and coalescence is used to estimate operating parameters for a full-scale system, and the cost of operating the system per unit CO2 captured is estimated. The analysis indicates that CO2 capture from air for climate change mitigation is technically feasible using off-the-shelf technology. Drop coalescence significantly decreases the CO2 absorption efficiency; however, fan and pump energy requirements are manageable. Water loss is significant (20 mol H2O/mol CO2 at 15 degrees C and 65% RH) but can be lowered by appropriately designing and operating the system. The cost of CO2 capture using NaOH spray (excluding solution recovery and CO2 sequestration, which may be comparable) in the full-scale system is 96 $/ton-CO2 in the base case, and ranges from 53 to 127 $/ton-CO2 under alternate operating parameters and assumptions regarding capital costs and mass transfer rate. The low end of the cost range is reached by a spray with 50 microm mean drop diameter, which is achievable with commercially available spray nozzles.

  18. Heat transfer test of an 0.006-scale thin-skin thermocouple space shuttle model (50-0, 41-T) in the NASA-Ames Research Center 3.5-foot hypersonic wind tunnel at Mach 5.3 (IH28), volume 1

    NASA Technical Reports Server (NTRS)

    Cummings, J. W.; Foster, T. F.; Lockman, W. K.

    1976-01-01

    Data obtained from a heat transfer test conducted on an 0.006-scale space shuttle orbiter and external tank in the NASA-Ames Research Center 3.5-foot Hypersonic Wind Tunnel are presented. The purpose of this test was to obtain data under simulated return-to-launch-site abort conditions. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone at angles of attack of 0, + or - 30, + or - 60, + or - 90, and + or - 120 degrees. Runs were conducted at Mach numbers of 5.2 and 5.3 for Reynolds numbers of 1.0 and 4.0 million per foot, respectively. Heat transfer data were obtained from 75 orbiter and 75 external tank iron-constantan thermocouples.

  19. 40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...

  20. 40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...

  1. Hydrodynamic shrinkage of liquid CO2 Taylor drops in a straight microchannel

    NASA Astrophysics Data System (ADS)

    Qin, Ning; Wen, John Z.; Ren, Carolyn L.

    2018-03-01

    Hydrodynamic shrinkage of liquid CO2 drops in water under a Taylor flow regime is studied using a straight microchannel (length/width ~100). A general form of a mathematical model of the solvent-side mass transfer coefficient (k s) is developed first. Based on formulations of the surface area (A) and the volume (V) of a general Taylor drop in a rectangular microchannel, a specific form of k s is derived. Drop length and speed are experimentally measured at three specified positions of the straight channel, namely, immediately after drop generation (position 1), the midpoint of the channel (position 2) and the end of the channel (position 3). The reductions of drop length (L x , x  =  1, 2, 3) from position 1 to 2 and down to 3 are used to quantify the drop shrinkage. Using the specific model, k s is calculated mainly based on L x and drop flowing time (t). Results show that smaller CO2 drops produced by lower flow rate ratios ({{Q}LC{{O2}}}/{{Q}{{H2}O}} ) are generally characterized by higher (nearly three times) k s and Sherwood numbers than those produced by higher {{Q}LC{{O2}}}/{{Q}{{H2}O}} , which is essentially attributed to the larger effective portion of the smaller drop contributing in the mass transfer under same levels of the flowing time and the surface-to-volume ratio (~104 m-1) of all drops. Based on calculated pressure drops of the segmented flow in microchannel, the Peng-Robinson equation of state and initial pressures of drops at the T-junction in experiments, overall pressure drop (ΔP t) in the straight channel as well as the resulted drop volume change are quantified. ΔP t from position 1-3 is by average 3.175 kPa with a ~1.6% standard error, which only leads to relative drop volume changes of 0.3‰ to 0.52‰.

  2. Micro-Ring Structures Stabilize Microdroplets to Enable Long Term Spheroid Culture in 384 Hanging Drop Array Plates

    PubMed Central

    Hsiao, Amy Y.; Tung, Yi-Chung; Kuo, Chuan-Hsien; Mosadegh, Bobak; Bedenis, Rachel; Pienta, Kenneth J.; Takayama, Shuichi

    2012-01-01

    Using stereolithography, 20 different structural variations comprised of millimeter diameter holes surrounded by trenches, plateaus, or micro-ring structures were prepared and tested for their ability to stably hold arrays of microliter sized droplets within the structures over an extended period of time. The micro-ring structures were the most effective in stabilizing droplets against mechanical and chemical perturbations. After confirming the importance of micro-ring structures using rapid prototyping, we developed an injection molding tool for mass production of polystyrene 3D cell culture plates with an array of 384 such micro-ring surrounded through-hole structures. These newly designed and injection molded polystyrene 384 hanging drop array plates with micro-rings were stable and robust against mechanical perturbations as well as surface fouling-facilitated droplet spreading making them capable of long term cell spheroid culture of up to 22 days within the droplet array. This is a significant improvement over previously reported 384 hanging drop array plates which are susceptible to small mechanical shocks and could not reliably maintain hanging drops for longer than a few days. With enhanced droplet stability, the hanging drop array plates with micro-ring structures provide better platforms and open up new opportunities for high-throughput preparation of microscale 3D cell constructs for drug screening and cell analysis. PMID:22057945

  3. Micro-ring structures stabilize microdroplets to enable long term spheroid culture in 384 hanging drop array plates.

    PubMed

    Hsiao, Amy Y; Tung, Yi-Chung; Kuo, Chuan-Hsien; Mosadegh, Bobak; Bedenis, Rachel; Pienta, Kenneth J; Takayama, Shuichi

    2012-04-01

    Using stereolithography, 20 different structural variations comprised of millimeter diameter holes surrounded by trenches, plateaus, or micro-ring structures were prepared and tested for their ability to stably hold arrays of microliter sized droplets within the structures over an extended period of time. The micro-ring structures were the most effective in stabilizing droplets against mechanical and chemical perturbations. After confirming the importance of micro-ring structures using rapid prototyping, we developed an injection molding tool for mass production of polystyrene 3D cell culture plates with an array of 384 such micro-ring surrounded through-hole structures. These newly designed and injection molded polystyrene 384 hanging drop array plates with micro-rings were stable and robust against mechanical perturbations as well as surface fouling-facilitated droplet spreading making them capable of long term cell spheroid culture of up to 22 days within the droplet array. This is a significant improvement over previously reported 384 hanging drop array plates which are susceptible to small mechanical shocks and could not reliably maintain hanging drops for longer than a few days. With enhanced droplet stability, the hanging drop array plates with micro-ring structures provide better platforms and open up new opportunities for high-throughput preparation of microscale 3D cell constructs for drug screening and cell analysis.

  4. Metastability in plyometric training on unstable surfaces: a pilot study

    PubMed Central

    2014-01-01

    Background In the past, plyometric training (PT) has been predominantly performed on stable surfaces. The purpose of this pilot study was to examine effects of a 7-week lower body PT on stable vs. unstable surfaces. This type of exercise condition may be denoted as metastable equilibrium. Methods Thirty-three physically active male sport science students (age: 24.1 ± 3.8 years) were randomly assigned to a PT group (n = 13) exercising on stable (STAB) and a PT group (n = 20) on unstable surfaces (INST). Both groups trained countermovement jumps, drop jumps, and practiced a hurdle jump course. In addition, high bar squats were performed. Physical fitness tests on stable surfaces (hexagonal obstacle test, countermovement jump, hurdle drop jump, left-right hop, dynamic and static balance tests, and leg extension strength) were used to examine the training effects. Results Significant main effects of time (ANOVA) were found for the countermovement jump, hurdle drop jump, hexagonal test, dynamic balance, and leg extension strength. A significant interaction of time and training mode was detected for the countermovement jump in favor of the INST group. No significant improvements were evident for either group in the left-right hop and in the static balance test. Conclusions These results show that lower body PT on unstable surfaces is a safe and efficient way to improve physical performance on stable surfaces. PMID:25089202

  5. 40 CFR 53.60 - General provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it meets all requirements of § 53.63 (wind tunnel inlet aspiration test), § 53.65 (loading test), and § 53.66 (volatility... samplers shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it...

  6. 40 CFR 53.60 - General provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it meets all requirements of § 53.63 (wind tunnel inlet aspiration test), § 53.65 (loading test), and § 53.66 (volatility... samplers shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it...

  7. 40 CFR 53.60 - General provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it meets all requirements of § 53.63 (wind tunnel inlet aspiration test), § 53.65 (loading test), and § 53.66 (volatility... samplers shall not be subject to the requirements of § 53.62 (full wind tunnel test), provided that it...

  8. Bioinspired plate-based fog collectors.

    PubMed

    Heng, Xin; Luo, Cheng

    2014-09-24

    In a recent work, we explored the feeding mechanism of a shorebird to transport liquid drops by repeatedly opening and closing its beak. In this work, we apply the corresponding results to develop a new artificial fog collector. The collector includes two nonparallel plates. It has three advantages in comparison with existing artificial collectors: (i) easy fabrication, (ii) simple design to scale up, and (iii) active transport of condensed water drops. Two collectors have been built. A small one with dimensions of 4.2 × 2.1 × 0.05 cm(3) (length × width × thickness) was first built and tested to examine (i) the time evolution of condensed drop sizes and (ii) the collection processes and efficiencies on the glass, SiO2, and SU-8 plates. Under similar experimental conditions, the amount of water collected per unit area on the small collector is about 9.0, 4.7, and 3.7 times, respectively, as much as the ones reported for beetles, grasses, and metal wires, and the total amount of water collected is around 33, 18, and 15 times. On the basis of the understanding gained from the tests on the small collector, a large collector with dimensions of 26 × 10 × 0.2 cm(3) was further built and tested, which was capable of collecting 15.8 mL of water during a period of 36 min. The amount of water collected, when it is scaled from 36 to 120 min, is about 878, 479, or 405 times more than what was collected by individual beetles, grasses, or metal wires.

  9. TRACT 2 Frame Drop Test AT NASA Langley Research Center's Landin

    NASA Image and Video Library

    2014-05-09

    (Tract)2 Transport Rotorcraft Airframe Crash Testbed; Full Frame Drop Test: rotary wing crash worthiness, impact research at NASA Langley Research Center's Landing and Impact Research (LandIR) Facility Building 1297

  10. Osmotonicity of acetoacetate: possible implications for cerebral edema in diabetic ketoacidosis.

    PubMed

    Puliyel, Jacob M

    2003-04-01

    Rapid drops in blood glucose and sodium levels during treatment of diabetic ketoacidosis (DKA) can cause a drop in the osmotonicity of plasma, resulting in cerebral edema. Ketone bodies are assumed to move freely in and out of cells, so it is assumed that they do not contribute to the tonicity of plasma or influence fluid shifts. The assumption that ketone bodies do not contribute to osmotonicity has not been tested previously. The experiment described here was done to check if acetoacetate has osmotonicity. A modified erythrocyte fragility test was used to check the osmotonic and osmoprotective effects of the ketone body. Red blood cells were suspended in different test tubes containing distilled water, normal saline, glucose, urea and acetoacetic acid (lithium salt C4H5O3Li). All solutions (except the tube with distilled water) were made to match the osmolality of plasma. We hypothesized that solutions in which red cell hemolysis does not take place have greater tonicity than the tonicity of 0.45% saline. Spectrophotometry showed that there was no hemolysis in the solutions of normal saline or solutions containing glucose or acetoacetate. Complete hemolysis was demonstrated in the tube with plain distilled water and also in the solutions containing urea. This study shows that acetoacetate is functionally similar to glucose in that it contributes to increased osmotonicity. The drop in ketone body levels can produce a drop in the osmolar tonicity of plasma and precipitate cerebral edema.

  11. Tertiary treatment of textile wastewater with combined media biological aerated filter (CMBAF) at different hydraulic loadings and dissolved oxygen concentrations.

    PubMed

    Liu, Fang; Zhao, Chao-Cheng; Zhao, Dong-Feng; Liu, Guo-Hua

    2008-12-15

    An up-flow biological aerated filter packed with two layers media was employed for tertiary treatment of textile wastewater secondary effluent. Under steady state conditions, good performance of the reactor was achieved and the average COD, NH(4)(+)-N and total nitrogen (TN) in the effluent were 31, 2 and 8mg/L, respectively. For a fixed dissolved oxygen (DO) concentration, an increase of hydraulic loading resulted in a decrease in substrate removal. With the increase of hydraulic loadings from 0.13 to 0.78m(3)/(m(2)h), the removal efficiencies of COD, NH(4)(+)-N and TN all decreased, which dropped from 52 to 38%, from 90 to 68% and from 45 to 33%, respectively. In addition, the results also confirmed that the increase of COD and NH(4)(+)-N removal efficiencies resulted from the increase of DO concentrations, but this variation trend was not observed for TN removal. With the increase of DO concentrations from 2.4 to 6.1mg/L, the removal efficiencies of COD and NH(4)(+)-N were 39-53% and 64-88%, whenas TN removal efficiencies increased from 39 to 42% and then dropped to 35%.

  12. Hypertensive Crisis, Burden, Management, and Outcome at a Tertiary Care Center in Karachi.

    PubMed

    Almas, Aysha; Ghouse, Ayaz; Iftikhar, Ahmed Raza; Khursheed, Munawwar

    2014-01-01

    Objectives. Hypertension, if uncontrolled, can lead to hypertensive crisis. We aim to determine the prevalence of hypertensive crisis, its management, and outcome in patients presenting to a tertiary care center in Karachi. Methods. This was a cross-sectional study conducted at the Aga Khan University, Karachi, Pakistan. Adult inpatients (>18 yrs) presenting to the ER who were known hypertensive and had uncontrolled hypertension were included. Results. Out of 1336 patients, 28.6% (387) had uncontrolled hypertension. The prevalence of hypertensive crisis among uncontrolled hypertensive was 56.3% (218). Per oral calcium channel blocker; 35.4% (137) and intravenous nitrate; 22.7% (88) were the most commonly administered medication in the ER. The mean (SD) drop in SBP in patients with hypertensive crisis on intravenous treatment was 53.1 (29) mm Hg and on per oral treatment was 43 (27) mm Hg. The maximum mean (SD) drop in blood pressure was seen by intravenous sodium nitroprusside; 80 (51) mm Hg in SBP. Acute renal failure was the most common complication with a prevalence of 11.5% (24). Conclusion. The prevalence of hypertensive crisis is high. Per oral calcium channel blocker and intravenous nitrate are the most commonly administered medications in our setup.

  13. Expression, purification, crystallization and preliminary X-ray studies of Vibrio cholerae pseudopilin EpsH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raghunathan, Kannan; Vago, Frank S.; Ball, Terry

    2010-01-12

    EpsH is a minor pseudopilin protein of the Vibrio cholerae type II secretion system. A truncated form of EpsH with a C-terminal noncleavable His tag was constructed and expressed in Escherichia coli, purified and crystallized by sitting-drop vapor diffusion. A complete data set was collected to 1.71 {angstrom} resolution. The crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 53.39, b = 71.11, c = 84.64 {angstrom}. There were two protein molecules in the asymmetric unit, which gave a Matthews coefficient V{sub M} of 2.1 {angstrom}{sup 3} Da{sup -1}, corresponding to 41.5% solvent content.

  14. Seismological and geodetic constraints on the 2011 Mw5.3 Trinidad, Colorado earthquake and induced deformation in the Raton Basin

    USGS Publications Warehouse

    Barnhart, William D.; Benz, Harley M.; Hayes, Gavin P.; Rubinstein, Justin L.; Bergman, E.

    2014-01-01

    The Raton Basin of southern Colorado and northern New Mexico is an actively produced hydrocarbon basin that has experienced increased seismicity since 2001, including the August 2011 Mw5.3 Trinidad normal faulting event. Following the 2011 earthquake, regional seismic observations were used to relocate 21 events, including the 2011 main shock, two foreshocks, and 13 aftershocks. Additionally, interferometric synthetic aperture radar (InSAR) observations of both the 2011 event and preevent basin deformation place constraint on the spatial kinematics of the 2011 event and localized basin subsidence due to ground water or gas withdrawal. We find that the 2011 earthquake ruptured an 8–10 km long segment of a normal fault at depths of 1.5–6.0 km within the crystalline Precambrian basement underlying the Raton Basin sedimentary rocks. The earthquake also nucleated within the crystalline basement in the vicinity of an active wastewater disposal site. The ensuing aftershock sequence demonstrated statistical properties expected for intraplate earthquakes, though the length of the 2011 earthquake is unexpectedly long for an Mw5.3 event, suggesting that wastewater disposal may have triggered a low stress drop, otherwise natural earthquake. Additionally, preevent and postevent seismicity in the Raton Basin spatially correlates to regions of subsidence observed in InSAR time series analysis. While these observations cannot discern a causal link between hydrocarbon production and seismicity, they constrain spatial relationships between active basin deformation and geological and anthropogenic features. Furthermore, the InSAR observations highlight the utility of space-based geodetic observations for monitoring and assessing anthropogenically induced and triggered deformation.

  15. 14 CFR 63.53 - Knowledge requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., including flight planning and cruise control; (3) Practical meteorology, including analysis of weather maps... CERTIFICATION: FLIGHT CREWMEMBERS OTHER THAN PILOTS Flight Navigators § 63.53 Knowledge requirements. (a) An applicant for a flight navigator certificate must pass a written test on— (1) The regulations of this...

  16. 14 CFR 63.53 - Knowledge requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., including flight planning and cruise control; (3) Practical meteorology, including analysis of weather maps... CERTIFICATION: FLIGHT CREWMEMBERS OTHER THAN PILOTS Flight Navigators § 63.53 Knowledge requirements. (a) An applicant for a flight navigator certificate must pass a written test on— (1) The regulations of this...

  17. 14 CFR 63.53 - Knowledge requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., including flight planning and cruise control; (3) Practical meteorology, including analysis of weather maps... CERTIFICATION: FLIGHT CREWMEMBERS OTHER THAN PILOTS Flight Navigators § 63.53 Knowledge requirements. (a) An applicant for a flight navigator certificate must pass a written test on— (1) The regulations of this...

  18. A laboratory measurement of drop impact on a water surface in the presence of wind

    NASA Astrophysics Data System (ADS)

    Liu, Xinan; Liu, Ren

    2014-11-01

    The impact of single water drops on a water surface was studied experimentally in a wind tunnel. Water drops were generated from a needle oriented vertically from the top of the wind tunnel test section. After leaving the needle, the drops move downward due to gravity and downstream due to the effect of the wind, eventually impinging obliquely on the surface of a pool of water on the bottom of the test section. The vertical velocities of drops were about 2.0 m/s and the wind speeds varied from 0 to 6.4 m/s. The drop impacts were recorded simultaneously from the side and above with two high-speed movie cameras with frame rates of 1,000 Hz. Our measurements show that both wind speed and initial drop size dramatically affect the drop impacts and subsequent generation of crowns, secondary drops, stalks and ring waves. In the presence of wind, an asymmetric crown forms after the drop hits the water surface and secondary drops are generated from the fragmentation of the leeward side of the crown rim. This is followed by a stalk formation and ring waves at the location of the water drop impact. It is found that the stalks tilt to leeward and the ring waves in the windward direction are stronger than that in those in the leeward. This work is supported by National Science Foundation, Division of Ocean Sciences.

  19. Recommendations to Improve No Child Left Behind for Struggling Students and Disconnected Youth

    ERIC Educational Resources Information Center

    Tsoi-A-Fatt, Rhonda; Harris, Linda; Thakur, Mala; Larsen, Jonathan

    2007-01-01

    Every day, an estimated 2,500 students across the nation drop out of high school. In the last decade, approximately 30 percent of students who enrolled in high school have failed to graduate four years later. The situation is even more dismal for youth of color. In 2003, only 55 percent of African Americans and 53 percent of Hispanics graduated…

  20. Effect of using a treadmill workstation on performance of simulated office work tasks.

    PubMed

    John, Dinesh; Bassett, David; Thompson, Dixie; Fairbrother, Jeffrey; Baldwin, Debora

    2009-09-01

    Although using a treadmill workstation may change the sedentary nature of desk jobs, it is unknown if walking while working affects performance on office-work related tasks. To assess differences between seated and walking conditions on motor skills and cognitive function tests. Eleven males (24.6 +/- 3.5 y) and 9 females (27.0 +/- 3.9 y) completed a test battery to assess selective attention and processing speed, typing speed, mouse clicking/drag-and-drop speed, and GRE math and reading comprehension. Testing was performed under seated and walking conditions on 2 separate days using a counterbalanced, within subjects design. Participants did not have an acclimation period before the walking condition. Paired t tests (P < .05) revealed that in the seated condition, completion times were shorter for mouse clicking (26.6 +/- 3.0 vs. 28.2 +/- 2.5s) and drag-and-drop (40.3 +/- 4.2 vs. 43.9 +/- 2.5s) tests, typing speed was greater (40.2 +/- 9.1 vs. 36.9 +/- 10.2 adjusted words x min(-1)), and math scores were better (71.4 +/- 15.2 vs. 64.3 +/- 13.4%). There were no significant differences between conditions in selective attention and processing speed or in reading comprehension. Compared with the seated condition, treadmill walking caused a 6% to 11% decrease in measures of fine motor skills and math problem solving, but did not affect selective attention and processing speed or reading comprehension.

  1. Combining spray nozzle simulators with meshes: characterization of rainfall intensity and drop properties

    NASA Astrophysics Data System (ADS)

    Carvalho, Sílvia C. P.; de Lima, João L. M. P.; de Lima, M. Isabel P.

    2013-04-01

    Rainfall simulators can be a powerful tool to increase our understanding of hydrological and geomorphological processes. Nevertheless, rainfall simulators' design and operation might be rather demanding, for achieving specific rainfall intensity distributions and drop characteristics. The pressurized simulators have some advantages over the non-pressurized simulators: drops do not rely on gravity to reach terminal velocity, but are sprayed out under pressure; pressurized simulators also yield a broad range of drop sizes in comparison with drop-formers simulators. The main purpose of this study was to explore in the laboratory the potential of combining spray nozzle simulators with meshes in order to change rainfall characteristics (rainfall intensity and diameters and fall speed of drops). Different types of spray nozzles were tested, such as single full-cone and multiple full-cone nozzles. The impact of the meshes on the simulated rain was studied by testing different materials (i.e. plastic and steel meshes), square apertures and wire thicknesses, and different vertical distances between the nozzle and the meshes underneath. The diameter and fall speed of the rain drops were measured using a Laser Precipitation Monitor (Thies Clima). The rainfall intensity range and coefficients of uniformity of the sprays and the drop size distribution, fall speed and kinetic energy were analysed. Results show that when meshes intercept drop trajectories the spatial distribution of rainfall intensity and the drop size distribution are affected. As the spray nozzles generate typically small drop sizes and narrow drop size distributions, meshes can be used to promote the formation of bigger drops and random their landing positions.

  2. Heat transfer and pressure drop measurements in an air/molten salt direct-contact heat exchanger

    NASA Astrophysics Data System (ADS)

    Bohn, Mark S.

    1988-11-01

    This paper presents a comparison of experimental data with a recently published model of heat exchange in irrigated packed beds. Heat transfer and pressure drop were measured in a 150 mm (ID) column with a 610 mm bed of metal Pall rings. Molten nitrate salt and preheated air were the working fluids with a salt inlet temperature of approximately 440 C and air inlet temperatures of approximately 230 C. A comparison between the experimental data and the heat transfer model is made on the basis of heat transfer from the salt. For the range of air and salt flow rates tested, 0.3 to 1.2 kg/sq m/s air flow and 6 to 18 kg/sq m/s salt flow, the data agree with the model within 22 percent standard deviation. In addition, a model for the column pressure drop was validated, agreeing with the experimental data within 18 percent standard deviation over the range of column pressure drop from 40 to 1250 Pa/m.

  3. Pressure, temperature and density drops along supercritical fluid chromatography columns. I. Experimental results for neat carbon dioxide and columns packed with 3- and 5-micron particles.

    PubMed

    Poe, Donald P; Veit, Devon; Ranger, Megan; Kaczmarski, Krzysztof; Tarafder, Abhijit; Guiochon, Georges

    2012-08-10

    The pressure drop and temperature drop on columns packed with 3- and 5-micron particles were measured using neat CO(2) at a flow rate of 5 mL/min, at temperatures from 20°C to 100°C, and outlet pressures from 80 to 300 bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath either bare or covered with foam insulation. The results show that the pressure drop depends on the outlet pressure, the operating temperature, and the thermal environment. A temperature drop was observed for all conditions studied. The temperature drop was relatively small (less than 3°C) for combinations of low temperature and high pressure. Larger temperature drops and density drops occurred at higher temperatures and low to moderate pressures. Covering the column with thermal insulation resulted in larger temperature drops and corresponding smaller density drops. At 20°C the temperature drop was never more than a few degrees. The largest temperature drops occurred for both columns when insulated at 80°C and 80 bar, reaching a maximum value of 21°C for the 5-micron column, and 26°C for the 3-micron column. For an adiabatic column, the temperature drop depends on the pressure drop, the thermal expansion coefficient, and the density and the heat capacity of the mobile phase fluid, and can be described by a simple mathematical relationship. For a fixed operating temperature and outlet pressure, the temperature drop increases monotonically with the pressure drop. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Inhibition of hexokinase-2 with targeted liposomal 3-bromopyruvate in an ovarian tumor spheroid model of aerobic glycolysis

    PubMed Central

    Gandham, Srujan Kumar; Talekar, Meghna; Singh, Amit; Amiji, Mansoor M

    2015-01-01

    Background The objective of this study was to evaluate the expression levels of glycolytic markers, especially hexokinase-2 (HK2), using a three-dimensional multicellular spheroid model of human ovarian adenocarcinoma (SKOV-3) cells and to develop an epidermal growth factor receptor-targeted liposomal formulation for improving inhibition of HK2 and the cytotoxicity of 3-bromopyruvate (3-BPA). Methods Multicellular SKOV-3 tumor spheroids were developed using the hanging drop method and expression levels of glycolytic markers were examined. Non-targeted and epidermal growth factor receptor-targeted liposomal formulations of 3-BPA were formulated and characterized. Permeability and cellular uptake of the liposomal formulations in three-dimensional SKOV-3 spheroids was evaluated using confocal microscopy. The cytotoxicity and HK2 inhibition potential of solution form of 3-BPA was compared to the corresponding liposomal formulation by using cell proliferation and HK2 enzymatic assays. Results SKOV-3 spheroids were reproducibly developed using the 96-well hanging drop method, with an average size of 900 µm by day 5. HK2 enzyme activity levels under hypoxic conditions were found to be higher than under normoxic conditions (P<0.0001, Student’s t-test, unpaired and two-tailed). Liposomal formulations (both non-targeted and targeted) of 3-BPA showed a more potent inhibitory effect (P<0.001, Student’s t-test, unpaired and two-tailed) at a dose of 50 µM than the aqueous solution form at 3, 6, and 24 hours post administration. Similarly, the cytotoxic activity 3-BPA at various concentrations (10 µM–100 µM) showed that the liposomal formulations had an enhanced cytotoxic effect of 2–5-fold (P<0.0001, Student’s t-test, unpaired and two-tailed) when compared to the aqueous solution form for both 10 µM and 25 µM concentrations. Conclusion SKOV-3 spheroids developed by the hanging drop method can be used as a tumor aerobic glycolysis model for evaluation of therapies targeting the glycolytic pathway in cancer cells. Encapsulation of 3-BPA in a liposomal formulation improved permeability, HK2 inhibition, and cytotoxicity in the multicellular spheroid model. PMID:26185443

  5. Inhibition of hexokinase-2 with targeted liposomal 3-bromopyruvate in an ovarian tumor spheroid model of aerobic glycolysis.

    PubMed

    Gandham, Srujan Kumar; Talekar, Meghna; Singh, Amit; Amiji, Mansoor M

    2015-01-01

    The objective of this study was to evaluate the expression levels of glycolytic markers, especially hexokinase-2 (HK2), using a three-dimensional multicellular spheroid model of human ovarian adenocarcinoma (SKOV-3) cells and to develop an epidermal growth factor receptor-targeted liposomal formulation for improving inhibition of HK2 and the cytotoxicity of 3-bromopyruvate (3-BPA). Multicellular SKOV-3 tumor spheroids were developed using the hanging drop method and expression levels of glycolytic markers were examined. Non-targeted and epidermal growth factor receptor-targeted liposomal formulations of 3-BPA were formulated and characterized. Permeability and cellular uptake of the liposomal formulations in three-dimensional SKOV-3 spheroids was evaluated using confocal microscopy. The cytotoxicity and HK2 inhibition potential of solution form of 3-BPA was compared to the corresponding liposomal formulation by using cell proliferation and HK2 enzymatic assays. SKOV-3 spheroids were reproducibly developed using the 96-well hanging drop method, with an average size of 900 µm by day 5. HK2 enzyme activity levels under hypoxic conditions were found to be higher than under normoxic conditions (P<0.0001, Student's t-test, unpaired and two-tailed). Liposomal formulations (both non-targeted and targeted) of 3-BPA showed a more potent inhibitory effect (P<0.001, Student's t-test, unpaired and two-tailed) at a dose of 50 µM than the aqueous solution form at 3, 6, and 24 hours post administration. Similarly, the cytotoxic activity 3-BPA at various concentrations (10 µM-100 µM) showed that the liposomal formulations had an enhanced cytotoxic effect of 2-5-fold (P<0.0001, Student's t-test, unpaired and two-tailed) when compared to the aqueous solution form for both 10 µM and 25 µM concentrations. SKOV-3 spheroids developed by the hanging drop method can be used as a tumor aerobic glycolysis model for evaluation of therapies targeting the glycolytic pathway in cancer cells. Encapsulation of 3-BPA in a liposomal formulation improved permeability, HK2 inhibition, and cytotoxicity in the multicellular spheroid model.

  6. Impact, thermal, and shock sensitivity of molten TNT and of asphalt-contaminated molten TNT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mainiero, R.J.; Miron, Y.; Kwak, S.S.W.

    1996-12-01

    The research reported here was part of an effort to evaluate the safety of a process to recover TNT from MK-9 depth bombs by the autoclave meltout process. In this process the depth bombs are heated to 121 C so that the TNT will melt and run into a vat. Unfortunately, asphalt lining the inside surface of the bomb also melts and flows out with the TNT. Testing was conducted on molten TNT and molten TNT contaminated with 2 pct asphalt at 90, 100, 110, 120, 125, and 130 C. In the liquid drop test apparatus with a 2-kg weight,more » the molten TNT yielded a 50 pct probability of initiation at a drop height of 6.5 cm at 110 C, decreasing to 4.5 cm at 130 C. Asphalt-contaminated TNT was somewhat less impact-sensitive than pure TNT at temperatures of 110 to 125 C, but became more sensitive at 130 C. There is a 50 pct probability of initiation at a drop height of 7.8 cm at 110 C, decreasing to 3.3 cm at 130 C. In the card gap test, the molten TNT detonated at high velocity for a gap of 0.25 inches at 90 to 125 C and detonated at high velocity for a gap of 0.5 inches at 130 C. For gaps of 0.5 to 3 inches at 90 to 125 C and 0.75 inches to 3 inches at 130 C, the TNT did not detonate at high velocity but produced a violent explosion that caused significant damage to the test fixture. The thermal analysis test results showed that when asphalt is present in TNT, it greatly accelerates the exothermic decomposition of TNT, starting at temperatures near 200 C. It appears that at relatively low shock stimulus levels, the molten TNT may be undergoing a low velocity detonation, wherein the shock wave traveling through the gap test pipe cavitates the molten TNT, greatly increasing its sensitivity. These results are crucial for assuring continued safety in recovering TNT from munitions through the autoclave meltout process.« less

  7. Silencing of p53 RNA through transarterial delivery ameliorates renal tubular injury and downregulates GSK-3β expression after ischemia-reperfusion injury.

    PubMed

    Fujino, Takayuki; Muhib, Sharifi; Sato, Nobuyuki; Hasebe, Naoyuki

    2013-12-01

    p53, a pivotal protein in the apoptotic pathway, has been identified as a mediator of transcriptional responses to ischemia-reperfusion (IR) injury. The characteristics and functional significance of the p53 response in vivo are largely unknown in IR-induced kidney injury. Therapeutic opportunities of delivering small interfering RNA (siRNA) via venous injection have gained recognition; however, systemic adverse effects of siRNA therapy should be considered. To prevent IR-induced kidney injury, we tested the efficacy of transarterial administration of siRNA targeting p53 (p53 siRNA). Female C57BL/6 mice underwent unilateral renal artery ischemia for 30 min, followed by reperfusion. siRNA experiments utilized short hairpin (sh) RNA plasmid-based approaches. Transfection of shRNA was performed using cationic polymer transfection reagent. Injection of synthetic p53 shRNA into the left renal artery just after ischemia improved tubular injury, apoptosis, and the swelling of mitochondria in cells of the thick ascending limb of Henle (mTALH) at the outer medullary regions. Staining of upregulated p53 was colocalized with the inducible expression of glycogen synthase kinase-3β (GSK-3β) at mTALH after IR injury. p53 shRNA inhibited GSK-3β expression and restored β-catenin expression at mTALH. For IR-induced kidney injury, transarterial delivery of p53 siRNA is an effective pharmacological intervention. Targeting siRNA to p53 leads to an attenuation of apoptosis and mitochondrial damage through the downregulation of GSK-3β expression and upregulation of β-catenin. Local delivery of vectors such as p53 siRNA through a transaortic catheter is clinically useful in reducing the adverse effect of siRNA-related therapy.

  8. Decreasing the occurrence of intraoperative technical errors through periodic simple show, tell and learn method.

    PubMed

    Steinberg, Ely L; Amar, Eyal; Albagli, Assaf; Rath, Ehud; Salai, Moshe

    2014-08-01

    Technical errors (TE) that occur during surgery for treating fractures are considered as being preventable by good preoperative planning and surgeon education. This prospective study evaluated a new instructional method for improving surgical outcomes that involved assessing surgeons' own recent performances. Postoperative radiographs from two groups of patients were assessed during consecutive 4-month periods. 350 operations were included in the Early Group and 411 operations in the Late Group. All the TE that occurred during the first period were reviewed and discussed among the residents and the consultant surgeons who had performed those operations. The same procedure was followed 4 months later. The TE were classified as minor, moderate and major. The two groups included the same 41 surgeons. The most common TE were: insufficient reduction, varus and valgus malalignment and prominent hardware. The total number of errors dropped significantly, from 52 (14.7%) during the first period to 26 (6.3%) during the second period (p = 0.0003). The TE score severity dropped from 81 to 38, respectively (p = 0.0001). The most affected regions were, the humerus (p < 000.1), midshaft femur (p = 0.007), proximal femur (p = 0.004) and radius (p = 0.008). Most of the gains were made in the moderate category (p = 0.0001). The consultants performed statistically better than the residents in the first period (12% vs. 20%, p = 0.036), but almost similar to the residents in the second period (5.3% vs. 9%, p = 0.164). A TE index was calculated by dividing the accumulated sum by the number of operations and it dropped in both groups from 0.2 and 0.3 to 0.09 and 0.09, respectively. Intraoperative TE can be significantly reduced by periodic performance evaluations in a seminar setting during which groups of surgeons can review the TE that they and their colleagues had made during recent orthopaedic surgical procedures. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Critical point wetting drop tower experiment

    NASA Technical Reports Server (NTRS)

    Kaukler, W. F.; Tcherneshoff, L. M.; Straits, S. R.

    1984-01-01

    Preliminary results for the Critical Point Wetting CPW Drop Tower Experiment are produced with immiscible systems. Much of the observed phenomena conformed to the anticipated behavior. More drops will be needed to test the CPW theory with these immiscible systems.

  10. pH-dependent conformational changes of diphtheria toxin adsorbed to lipid monolayers by neutron and X-ray reflection

    NASA Astrophysics Data System (ADS)

    Kent, Michael; Yim, Hyun; Satija, Sushil; Kuzmenko, Ivan

    2006-03-01

    Several important bacterial toxins, such as diphtheria, tetanus, and botulinum, invade cells through a process of high affinity binding, internalization via endosome formation, and subsequent membrane penetration of the catalytic domain activated by a pH drop in the endosome. These toxins are composed of three domains: a binding domain, a translocation domain, and an enzyme. The translocation process is not well understood with regard to the detailed conformational changes that occur at each step, To address this, we performed neutron reflectivity measurements for diphtheria toxin bound to lipid monolayers as a function of pH. While the final membrane inserted conformation will not be reproduced with the present monolayer system, important insights can still be gained into several intermediate stages. In particular, we show that no adsorption occurs at pH = 7.6, but strong adsorption occurs over at a pH range from 6.5 to 6.0. Following binding, at least two stages of conformational change occur, as the thickness increases from pH 6.3 to 5.3 and then decreases from pH 5.3 to 4.5. In addition, the dimension of the adsorbed layer substantially exceeds that of the largest dimension in the crystal structure of monomeric diphtheria, suggesting that the toxin may be present as multimers.

  11. Noncontact measurement of high temperature using optical fiber sensors

    NASA Technical Reports Server (NTRS)

    Claus, R. O.

    1990-01-01

    The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

  12. Revision of Bubble Bursting: Universal Scaling Laws of Top Jet Drop Size and Speed.

    PubMed

    Gañán-Calvo, Alfonso M

    2017-11-17

    The collapse of a bubble of radius R_{o} at the surface of a liquid generating a liquid jet and a subsequent first drop of radius R is universally scaled using the Ohnesorge number Oh=μ/(ρσR_{o})^{1/2} and a critical value Oh^{*} below which no droplet is ejected; ρ, σ, and μ are the liquid density, surface tension, and viscosity, respectively. First, a flow field analysis at ejection yields the scaling of R with the jet velocity V as R/l_{μ}∼(V/V_{μ})^{-5/3}, where l_{μ}=μ^{2}/(ρσ) and V_{μ}=σ/μ. This resolves the scaling problem of curvature reversal, a prelude to jet formation. In addition, the energy necessary for the ejection of a jet with a volume and averaged velocity proportional to R_{o}R^{2} and V, respectively, comes from the energy excess from the total available surface energy, proportional to σR_{o}^{2}, minus the one dissipated by viscosity, proportional to μ(σR_{o}^{3}/ρ)^{1/2}. Using the scaling variable φ=(Oh^{*}-Oh)Oh^{-2}, it yields V/V_{μ}=k_{v}φ^{-3/4} and R/l_{μ}=k_{d}φ^{5/4}, which collapse published data since 1954 and resolve the scaling of R and V with k_{v}=16, k_{d}=0.6, and Oh^{*}=0.043 when gravity effects are negligible.

  13. Manufacturing Methods for High Speed Machining of Aluminum

    DTIC Science & Technology

    1978-02-01

    Tests 53 4.4.3 Intergrmnular Corrosion Tests. ........... 53 4.4.4 Cost Analysis . .. ............... . .. .... 60 4.5 Conclusions...Corporat~ion and Others to equuip an existing Uwidstvahd, five-axes, Modal as-i, oidail with a 20,000 rVIL 20 hOW~pse spindle, Based anresults obtained...economic analysis for high-speed machining wan also conducted by Metout, and the results are given in Section 11.0. Xn Section 12.0, conclusions and

  14. Forming chondrules in impact splashes. I. Radiative cooling model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dullemond, Cornelis Petrus; Stammler, Sebastian Markus; Johansen, Anders

    2014-10-10

    The formation of chondrules is one of the oldest unsolved mysteries in meteoritics and planet formation. Recently an old idea has been revived: the idea that chondrules form as a result of collisions between planetesimals in which the ejected molten material forms small droplets that solidify to become chondrules. Pre-melting of the planetesimals by radioactive decay of {sup 26}Al would help produce sprays of melt even at relatively low impact velocity. In this paper we study the radiative cooling of a ballistically expanding spherical cloud of chondrule droplets ejected from the impact site. We present results from numerical radiative transfermore » models as well as analytic approximate solutions. We find that the temperature after the start of the expansion of the cloud remains constant for a time t {sub cool} and then drops with time t approximately as T ≅ T {sub 0}[(3/5)t/t {sub cool} + 2/5]{sup –5/3} for t > t {sub cool}. The time at which this temperature drop starts t {sub cool} depends via an analytical formula on the mass of the cloud, the expansion velocity, and the size of the chondrule. During the early isothermal expansion phase the density is still so high that we expect the vapor of volatile elements to saturate so that no large volatile losses are expected.« less

  15. Development of a Methodology to Conduct Usability Evaluation for Hand Tools that May Reduce the Amount of Small Parts that are Dropped During Installation while Processing Space Flight Hardware

    NASA Technical Reports Server (NTRS)

    Miller, Darcy

    2000-01-01

    Foreign object debris (FOD) is an important concern while processing space flight hardware. FOD can be defined as "The debris that is left in or around flight hardware, where it could cause damage to that flight hardware," (United Space Alliance, 2000). Just one small screw left unintentionally in the wrong place could delay a launch schedule while it is retrieved, increase the cost of processing, or cause a potentially fatal accident. At this time, there is not a single solution to help reduce the number of dropped parts such as screws, bolts, nuts, and washers during installation. Most of the effort is currently focused on training employees and on capturing the parts once they are dropped. Advances in ergonomics and hand tool design suggest that a solution may be possible, in the form of specialty hand tools, which secure the small parts while they are being handled. To assist in the development of these new advances, a test methodology was developed to conduct a usability evaluation of hand tools, while performing tasks with risk of creating FOD. The methodology also includes hardware in the form of a testing board and the small parts that can be installed onto the board during a test. The usability of new hand tools was determined based on efficiency and the number of dropped parts. To validate the methodology, participants were tested while performing a task that is representative of the type of work that may be done when processing space flight hardware. Test participants installed small parts using their hands and two commercially available tools. The participants were from three groups: (1) students, (2) engineers / managers and (3) technicians. The test was conducted to evaluate the differences in performance when using the three installation methods, as well as the difference in performance of the three participant groups.

  16. Examining the safety of menstrual cups among rural primary school girls in western Kenya: observational studies nested in a randomised controlled feasibility study

    PubMed Central

    Juma, Jane; Nyothach, Elizabeth; Laserson, Kayla F; Oduor, Clifford; Arita, Lilian; Ouma, Caroline; Oruko, Kelvin; Omoto, Jackton; Mason, Linda; Alexander, Kelly T; Fields, Barry; Onyango, Clayton; Phillips-Howard, Penelope A

    2017-01-01

    Objective Examine the safety of menstrual cups against sanitary pads and usual practice in Kenyan schoolgirls. Design Observational studies nested in a cluster randomised controlled feasibility study. Setting 30 primary schools in a health and demographic surveillance system in rural western Kenya. Participants Menstruating primary schoolgirls aged 14–16 years participating in a menstrual feasibility study. Interventions Insertable menstrual cup, monthly sanitary pads or ‘usual practice’ (controls). Outcome measures Staphylococcus aureus vaginal colonization, Escherichia coli growth on sampled used cups, toxic shock syndrome or other adverse health outcomes. Results Among 604 eligible girls tested, no adverse event or TSS was detected over a median 10.9 months follow-up. S. aureusprevalence was 10.8%, with no significant difference over intervention time or between groups. Of 65 S.aureus positives at first test, 49 girls were retested and 10 (20.4%) remained positive. Of these, two (20%) sample isolates tested positive for toxic shock syndrome toxin-1; both girls were provided pads and were clinically healthy. Seven per cent of cups required replacements for loss, damage, dropping in a latrine or a poor fit. Of 30 used cups processed for E. coli growth, 13 (37.1%, 95% CI 21.1% to 53.1%) had growth. E. coli growth was greatest in newer compared with established users (53%vs22.2%, p=0.12). Conclusions Among this feasibility sample, no evidence emerged to indicate menstrual cups are hazardous or cause health harms among rural Kenyan schoolgirls, but large-scale trials and post-marketing surveillance should continue to evaluate cup safety. PMID:28473520

  17. Examining the safety of menstrual cups among rural primary school girls in western Kenya: observational studies nested in a randomised controlled feasibility study.

    PubMed

    Juma, Jane; Nyothach, Elizabeth; Laserson, Kayla F; Oduor, Clifford; Arita, Lilian; Ouma, Caroline; Oruko, Kelvin; Omoto, Jackton; Mason, Linda; Alexander, Kelly T; Fields, Barry; Onyango, Clayton; Phillips-Howard, Penelope A

    2017-05-04

    Examine the safety of menstrual cups against sanitary pads and usual practice in Kenyan schoolgirls. Observational studies nested in a cluster randomised controlled feasibility study. 30 primary schools in a health and demographic surveillance system in rural western Kenya. Menstruating primary schoolgirls aged 14-16 years participating in a menstrual feasibility study. Insertable menstrual cup, monthly sanitary pads or 'usual practice' (controls). Staphylococcus aureus vaginal colonization, Escherichia coli growth on sampled used cups, toxic shock syndrome or other adverse health outcomes. Among 604 eligible girls tested, no adverse event or TSS was detected over a median 10.9 months follow-up. S. aureus prevalence was 10.8%, with no significant difference over intervention time or between groups. Of 65  S.aureus positives at first test, 49 girls were retested and 10 (20.4%) remained positive. Of these, two (20%) sample isolates tested positive for toxic shock syndrome toxin-1; both girls were provided pads and were clinically healthy. Seven per cent of cups required replacements for loss, damage, dropping in a latrine or a poor fit. Of 30 used cups processed for E. coli growth, 13 (37.1%, 95% CI 21.1% to 53.1%) had growth. E. coli growth was greatest in newer compared with established users (53%vs22.2%, p=0.12). Among this feasibility sample, no evidence emerged to indicate menstrual cups are hazardous or cause health harms among rural Kenyan schoolgirls, but large-scale trials and post-marketing surveillance should continue to evaluate cup safety. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Deployment and Drop Test of Inflatable Aeroshell for Atmospheric Entry Capsule with using Large Scientific Balloon

    NASA Astrophysics Data System (ADS)

    Yamada, Kazuhiko; Suzuki, Kojiro; Honma, Naohiko; Abe, Daisuke; Makino, Hitoshi; Nagata, Yasunori; Kimura, Yusuke; Koyama, Masashi; Akita, Daisuke; Hayashi, Koichi; Abe, Takashi

    A deployable and flexible aeroshell for atmospheric entry vehicles has attracted attention as an innovative space transportation system in the near future, because the large-area, low-mass aeroshell dramatically reduces aerodynamic heating and achieves a soft landing without a conventional parachute system thanks to its low ballistic coefficient. Various concepts of flexible aeroshell have been proposed in the past. Our group are researching and developing a flare-type membrane aeroshell sustained by inflatable torus. As a part of the development, a deployment and drop test of a capsule-type experimental vehicle with a 1.264-m-diameter flare-type membrane aeroshell sustained by inflatable torus was carried out using a large scientific balloon in August, 2009. The objectives of this experiment are 1) to demonstrate the remote inflation system of inflatable aeroshell, 2) to acquire aerodynamic performance of a low ballistic coefficient vehicle including an inflatable structure in subsonic region, and 3) to observe behavior and deformation of the flexible aeroshell during free flight. In this test, the inflatable aeroshell was deployed at an altitude 24.6km by radio command from ground station. After deployment, the experimental vehicle was dropped from the balloon and underwent free flight. The flight data and images of the aeroshell collected using onboard sensors were transmitted successfully during the flight by the telemetry system. The data showed that the vehicle was almost stable in free flight condition and the inflatable aeroshell was collapsed at expected altitude. This deployment and drop test was very successful and useful data for design of actual atmospheric-entry vehicles with inflatable structure was acquired as planned.

  19. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specified in the post-loading evaluation test (§ 53.62, § 53.63, or § 53.64). § 53.66 Volatility Test... Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel Evaluation...: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr...

  20. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specified in the post-loading evaluation test (§ 53.62, § 53.63, or § 53.64). § 53.66 Volatility Test... Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel Evaluation...: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr...

  1. Changes in stature following plyometric drop-jump and pendulum exercises.

    PubMed

    Fowler, N E; Lees, A; Reilly, T

    1997-12-01

    The aim of this study was to compare the changes in stature following the performance of plyometric exercises using drop-jumps and a pendulum swing. Eight male participants aged 21.7 +/- 1.8 years with experience of plyometric training gave their informed consent to act as participants. Participants undertook two exercise regimens and a 15-min standing test in a random order. The exercises entailed the performance of 50 drop-jumps from a height of 0.28 m or 50 pendulum rebounds. Participants were instructed to perform maximal jumps or rebounds using a 'bounce' style. Measurements of stature were performed after a 20-min period of standing (pre-exercise), 2-min after exercise (post-exercise) and after a 20-min standing recovery (recovery). Back pain and muscle soreness were assessed using an analogue-visual scale, at each of the above times and also 24 and 36 h after the test. Peak torque during isokinetic knee extension at 1.04 rads-1 was measured immediately before and after the exercise bouts, to assess the degree of muscular fatigue. Ground/wall reaction force data were recorded using a Kistler force platform mounted in the floor for drop-jumps and vertically on the rebound wall for pendulum exercises. Drop-jumps resulted in the greatest (p < 0.05) change in stature (-2.71 +/- 0.8 mm), compared to pendulum exercises (-1.77 +/- 0.7 mm) and standing (-0.39 +/- 0.2 mm). Both exercise regimens resulted in a significant (p < 0.01) decrease in stature when compared to the standing condition. Drop-jumps resulted in significantly greater peak impact forces (p < 0.05) than pendulum exercises (drop-jumps = 3.2 +/- 0.5 x body weight, pendulum = 2.6 +/- 0.5 x body weight). The two exercise conditions both invoked a small degree of muscle soreness but there were no significant differences between conditions. Both exercise regimens resulted in a non-significant decrease in peak torque indicating a similar degree of muscular fatigue. Based on the lower shrinkage resulted and lower peak forces, it can be concluded that pendulum exercises pose a lower injury potential to the lower back than drop-jumps performed from a height of 28 cm.

  2. Determination of pressure drop across activated carbon fiber respirator cartridges.

    PubMed

    Balanay, Jo Anne G; Lungu, Claudiu T

    2016-01-01

    Activated carbon fiber (ACF) is considered as an alternative adsorbent to granular activated carbon (GAC) for the development of thinner, lighter, and efficient respirators because of their larger surface area and adsorption capacities, thinner critical bed depth, lighter weight, and fabric form. This study aims to measure the pressure drop across different types of commercially available ACFs in respirator cartridges to determine the ACF composition and density that will result in acceptably breathable respirators. Seven ACF types in cloth (ACFC) and felt (ACFF) forms were tested. ACFs in cartridges were challenged with pre-conditioned constant air flow (43 LPM, 23°C, 50% RH) at different compositions (single- or combination-ACF type) in a test chamber. Pressure drop across ACF cartridges were obtained using a micromanometer, and compared among different cartridge configurations, to those of the GAC cartridge, and to the NIOSH breathing resistance requirements for respirator cartridges. Single-ACF type cartridges filled with any ACFF had pressure drop measurements (23.71-39.93 mmH2O) within the NIOSH inhalation resistance requirement of 40 mmH2O, while those of the ACFC cartridges (85.47±3.67 mmH2O) exceeded twice the limit due possibly to the denser weaving of ACFC fibers. All single ACFF-type cartridges had higher pressure drop compared to the GAC cartridge (23.13±1.14 mmH2O). Certain ACF combinations (2 ACFF or ACFC/ACFF types) resulted to pressure drop (26.39-32.81 mmH2O) below the NIOSH limit. All single-ACFF type and all combination-ACF type cartridges with acceptable pressure drop had much lower adsorbent weights than GAC (≤15.2% of GAC weight), showing potential for light-weight respirator cartridges. 100% ACFC in cartridges may result to respirators with high breathing resistance and, thus, is not recommended. The more dense ACFF and ACFC types may still be possibly used in respirators by combining them with less dense ACFF materials and/or by reducing cartridge bed depth to reduce pressure drop to acceptable levels. ACFF by itself may be more appropriate as adsorbent materials in ACF respirator cartridges in terms of acceptable breathing resistance.

  3. Remotely operated high pressure valve protects test personnel

    NASA Technical Reports Server (NTRS)

    Howland, B. T.

    1967-01-01

    High pressure valve used in testing certain spacecraft systems is safely opened and closed by a remotely stationed operator. The valve is self-regulating in that if the incoming pressure drops below a desired value the valve will automatically close, warning the operator that the testing pressure has dropped to an undesired level.

  4. 14 CFR 29.725 - Limit drop test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Landing Gear § 29.725 Limit drop test. The... energy absorbing devices or by the use of an effective mass. (c) Each landing gear unit must be tested in... to be absorbed by it. (d) When an effective mass is used in showing compliance with paragraph (b) of...

  5. TP53-based interaction analysis identifies cis-eQTL variants for TP53BP2, FBXO28, and FAM53A that associate with survival and treatment outcome in breast cancer

    PubMed Central

    Fagerholm, Rainer; Khan, Sofia; Schmidt, Marjanka K.; GarcClosas, Montserrat; Heikkilä, Päivi; Saarela, Jani; Beesley, Jonathan; Jamshidi, Maral; Aittomäki, Kristiina; Liu, Jianjun; Raza Ali, H.; Andrulis, Irene L.; Beckmann, Matthias W.; Behrens, Sabine; Blows, Fiona M.; Brenner, Hermann; Chang-Claude, Jenny; Couch, Fergus J.; Czene, Kamila; Fasching, Peter A.; Figueroa, Jonine; Floris, Giuseppe; Glendon, Gord; Guo, Qi; Hall, Per; Hallberg, Emily; Hamann, Ute; Holleczek, Bernd; Hooning, Maartje J.; Hopper, John L.; Jager, Agnes; Kabisch, Maria; Investigators, kConFab/AOCS; Keeman, Renske; Kosma, Veli-Matti; Lambrechts, Diether; Lindblom, Annika; Mannermaa, Arto; Margolin, Sara; Provenzano, Elena; Shah, Mitul; Southey, Melissa C.; Dennis, Joe; Lush, Michael; Michailidou, Kyriaki; Wang, Qin; Bolla, Manjeet K.; Dunning, Alison M.; Easton, Douglas F.; Pharoah, Paul D.P .; Chenevix-Trench, Georgia; Blomqvist, Carl; Nevanlinna, Heli

    2017-01-01

    TP53 overexpression is indicative of somatic TP53 mutations and associates with aggressive tumors and poor prognosis in breast cancer. We utilized a two-stage SNP association study to detect variants associated with breast cancer survival in a TP53-dependent manner. Initially, a genome-wide study (n = 575 cases) was conducted to discover candidate SNPs for genotyping and validation in the Breast Cancer Association Consortium (BCAC). The SNPs were then tested for interaction with tumor TP53 status (n = 4,610) and anthracycline treatment (n = 17,828). For SNPs interacting with anthracycline treatment, siRNA knockdown experiments were carried out to validate candidate genes. In the test for interaction between SNP genotype and TP53 status, we identified one locus, represented by rs10916264 (p(interaction) = 3.44 05E010-5; FDR-adjusted p = 0.0011) in estrogen receptor (ER) positive cases. The rs10916264 AA genotype associated with worse survival among cases with ER-positive, TP53-positive tumors (hazard ratio [HR] 2.36, 95% confidence interval [C.I] 1.45 - 3.82). This is a cis-eQTL locus for FBXO28 and TP53BP2; expression levels of these genes were associated with patient survival specifically in ER-positive, TP53-mutated tumors. Additionally, the SNP rs798755 was associated with survival in interaction with anthracycline treatment (p(interaction) = 9.57 05E010-5, FDR-adjusted p = 0.0130). RNAi-based depletion of a predicted regulatory target gene, FAM53A, indicated that this gene can modulate doxorubicin sensitivity in breast cancer cell lines. If confirmed in independent data sets, these results may be of clinical relevance in the development of prognostic and predictive marker panels for breast cancer. PMID:28179588

  6. A theoretical and experimental study of turbulent nonevaporating sprays

    NASA Technical Reports Server (NTRS)

    Solomon, A. S. P.; Shuen, J. S.; Zhang, Q. F.; Faeth, G. M.

    1984-01-01

    Measurements and analysis limited to the dilute portions of turbulent nonevaporating sprays injected into a still air environment were completed. Mean and fluctuating velocities and Reynolds stress were measured in the continuous phase. Liquid phase measurements included liquid mass fluxes, drop sizes and drop size and velocity correlation. Initial conditions needed for model evaluation were measured at a location as close to the injector exit as possible. The test sprays showed significant effects of slip and turbulent dispersion of the discrete phase. The measurements were used to evaluate three typical models of these processes: (1) a locally homogenous flow (LHF) model, where slip between the phases were neglected; (2) a deterministic separated flow (DSF) model, where slip was considered but effects of drop dispersion by turbulence were ignored; and (3) a stochastic separated flow (SSF) model, where effects of interphase slip and turbulent dispersion were considered using random-walk computations for drop motion. The LHF and DSF models did not provide very satisfactory predictions for the present measurements. In contrast, the SSF model performed reasonably well with no modifications in the prescription of eddy properties from its original calibration. Some effects of drops on turbulence properties were observed near the dense regions of the sprays.

  7. Serration Behavior of a Zr-Based Metallic Glass Under Different Constrained Loading Conditions

    NASA Astrophysics Data System (ADS)

    Yang, G. N.; Gu, J. L.; Chen, S. Q.; Shao, Y.; Wang, H.; Yao, K. F.

    2016-11-01

    To understand the plastic behavior and shear band dynamics of metallic glasses (MGs) being tuned by the external constraint, uniaxial compression tests were performed on Zr41.2Ti13.8Cu12.5Ni10.0Be22.5 MG samples with aspect ratios of 0.5:1, 1:1, 1.5:1, 2:1, 2.5:1, and 3:1. Better plasticity was observed for the samples with smaller aspect ratio (under higher constraint degree). In the beginning of yielding, increasing serration (jerky stress drop) size on the loading curves was noticed for all samples. Statistical analysis of the serration patterns indicated that the small stress-drop serrations and large stress-drop serrations follow self-organized critical and chaotic dynamics, respectively. Under constrained loading, the large stress-drop serrations are depressed, while the small stress-drop serrations are less affected. When changing the external constraint level by varying the sample aspect ratio, the serration pattern, shear band dynamics, and plastic behavior will change accordingly. This study provides a perspective from tuning shear band dynamics to understand the plastic behavior of MGs under different external constraint.

  8. D.R.O.P: The Durable Reconnaissance and Observation Platform

    NASA Technical Reports Server (NTRS)

    McKenzie, Clifford; Parness, Aaron

    2011-01-01

    Robots can provide a remote presence in areas that are either inaccessible or too dangerous for humans. However, robots are often limited by their ability to adapt to the terrain or resist environmental factors. The Durable Reconnaissance and Observation Platform (DROP) is a lightweight robot that addresses these challenges with the capability to survive falls from significant heights, carry a useable payload, and traverse a variety of surfaces, including climbing vertical surfaces like wood, stone, and concrete. DROP is manufactured using a combination of rapid prototyping and shape deposition manufacturing. It uses microspine technology to create a new wheel-like design for vertical climbing. To date, DROP has successfully engaged several vertical surfaces, hanging statically without assistance, and traversed horizontal surfaces at approximately 30 cm/s. Unassisted vertical climbing is capable on surfaces up to 85deg at a rate of approximately 25cm*s(sup -1). DROP can also survive falls from up to 3 meters and has the ability to be thrown off of and onto rooftops. Future efforts will focus on improving the microspine wheels, selecting more resilient materials, customizing the controls, and performing more rigorous and quantifiable testing.

  9. The Classic Approach to Diagnosis of Vulvovaginitis: A Critical Analysis

    PubMed Central

    Lakovsky, Yaniv; Lavi, Idit; Bar-Am, Amiram; Abramovici, Haim

    2001-01-01

    Objective: To correlate the symptoms, signs and clinical diagnosis in women with vaginal discharge, based on the combined weight of the character of the vaginal discharge and bedside tests, with the laboratory diagnosis. Methods: Women presenting consecutively to the women's health center with vaginal discharge were interviewed and examined for assessment of the quantity and color of the discharge. One drop of the material was then examined for pH and the whiff test was done; a wet mount in saline and in 10% KOH was examined microscopically. The clinical diagnosis was based on the results of these assessments. Gram stain and cultures of the discharge were sent to the microbiology laboratory. Results: One hundred and fifty-threewomen with vaginal discharge with a clinical diagnosis of vulvovaginitis participated in the study. Fifty-five (35.9%) had normal flora and the other 98 (64.1%) had true infectious vulvovaginitis (k agreement = 18%). According to the laboratory, the principal infectious micro-organism causing the vulvovaginitis was Candida species. Candida infection was associated with pH levels of less than 4.5 (p < 0.0001, odds ratio = 4.74, 95% confidence interval: 2.35–9.5, positive predictive value 68.4%). The whiff test was positive in only a small percentage of bacterial vaginosis (BV) (p = not significant (NS)). Clue cells were documented in 53.3% of patients with a laboratory diagnosis of BV (p < 0.02, positive predictive value 26.7%). Conclusions: The current approach to the diagnosis of vulvovaginitis should be further studied. The classical and time-consuming assessments were shown not to be reliable diagnostic measures. PMID:11495550

  10. A Molecular Method to Detect Wound Cells in Bloodstains Resultant of Sharp Force Injuries for Crime Scene Reconstruction.

    PubMed

    Johnson, Donald J; Raymond, David E; Chen, Cynthia; Quon, Matthew; Lis, Julian; Choi, Mo Re; Lopez, Christopher; Han, Aileen; de Leon, Ray D; Bir, Cynthia

    2018-05-01

    Previous research by the authors on an animal model showed that bloodstains can contain additional information about their somatic origin in the form of wound cells. Bloodstains produced by a gunshot wound to the head were distinguished from bloodstains produced by a gunshot wound to the chest by testing the stains for a brain microRNA marker. In this study, the effectiveness of the technique was examined on blood drops shed externally from a stab wound to the liver of rat carcasses. Specifically, investigations were conducted on the liver microRNA marker, rno-mir-122-3p, with the QIAGEN miScript System, and PCR analysis. Between the two stabbing methods used, 67% of the scalpel blades and 57% of the blood drops tested positive for rno-mir-122-3p; however, other samples tested negative giving inconclusive results as to the wound-of-origin. The amount of the liver cells in the bloodstains appeared to be related to the extent of trauma. © 2017 American Academy of Forensic Sciences.

  11. Initial basalt target site selection evaluation for the Mars penetrator drop test

    NASA Technical Reports Server (NTRS)

    Bunch, T. E.; Quaide, W. L.; Polkowski, G.

    1976-01-01

    Potential basalt target sites for an air drop penetrator test were described and the criteria involved in site selection were discussed. A summary of the background field geology and recommendations for optimum sites are also presented.

  12. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions: Implications for Multicenter Biomechanical and Epidemiological Research on ACL Injury Prevention.

    PubMed

    DiCesare, Christopher A; Bates, Nathaniel A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie; Noehren, Brian W; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E; Myer, Gregory D

    2015-12-01

    Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Controlled laboratory study. Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.

  13. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions

    PubMed Central

    DiCesare, Christopher A.; Bates, Nathaniel A.; Barber Foss, Kim D.; Thomas, Staci M.; Wordeman, Samuel C.; Sugimoto, Dai; Roewer, Benjamin D.; Medina McKeon, Jennifer M.; Di Stasi, Stephanie; Noehren, Brian W.; Ford, Kevin R.; Kiefer, Adam W.; Hewett, Timothy E.; Myer, Gregory D.

    2015-01-01

    Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated. PMID:26779550

  14. 40 CFR 53.41 - Test conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test conditions. 53.41 Section 53.41... PM10 § 53.41 Test conditions. (a) Set-up and start-up of all test samplers shall be in strict... shall be cleaned prior to conducting wind tunnel tests with solid particles. (c) Once the test sampler...

  15. 40 CFR 53.41 - Test conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test conditions. 53.41 Section 53.41... PM10 § 53.41 Test conditions. (a) Set-up and start-up of all test samplers shall be in strict... shall be cleaned prior to conducting wind tunnel tests with solid particles. (c) Once the test sampler...

  16. The Correlation between Daily Lens Wear Duration and Dry Eye Syndrome.

    PubMed

    Lubis, Rodiah Rahmawaty; Gultom, Monica Tumiar Hanna

    2018-05-20

    To analyze the correlation between the daily lens wear duration and dry eye syndrome. This study was an analytic cross sectional study using consecutive sampling conducted among the students in Economy and Bussiness Faculty and Faculty of Humanities in University of Sumatera Utara aged between 17 to 23 that wore contact lens continously for at least a year and 5 days a week. The symptoms were assessed using Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and interview about their contact lens comfort; eye drops usage, contact lens washing habit, daily circumstances, places to buy contact lens and personal experince in wearing contact lens. The questionnaire was completed by 53 students. All of them were female and wore softlens wearers. The mean duration of daily wear was 8.19 ± 2.20 hours. The most common symptom experienced was dry eye and the least symptom experienced was removing lens. The most frequent symptom experienced was closing eyes and the least frequent symptom experienced was removing lenses. This study used Exact Test as analysis statistic method. The result was p > 0.05 which means there is no correlation between daily lens wear duration and dry eye syndrome. This study showed that dry eye syndrome was not correlated with daily lens wear duration, but affected by many factors such as contact lens, lens care solution, eye drops usage and environment.

  17. Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

    NASA Technical Reports Server (NTRS)

    Burns, Bradley M.; Blalock, Norman N.

    2010-01-01

    A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the switch and the inductor configuration. In the fault condition, both the resistor and the inductor react immediately. The resistor reacts by allowing more current to flow and dropping the voltage. Initially, the inductor reacts by dropping the voltage, and then by not allowing the current to change. When the comparator detects the drop in voltage, it opens the switch, thus preventing any further current flow. The inductor alone is not sufficient protection, because after the voltage drop has settled, the inductor would then allow the current to change, in this example, the current would be 3.7 A. In the fault condition, the resistor is flowing 200 mA until the fuse blows (anywhere from 1 ms to 100 s), while the switch and inductor combination is flowing about 2 A test current while monitoring for the fault to be corrected. Finally, as an additional safety feature, the circuit can be configured to hold the switch opened until both the load and source are disconnected.

  18. A novel lateral IGBT with a controlled anode for on-off-state loss trade-off improvement

    NASA Astrophysics Data System (ADS)

    Wensuo, Chen; Bo, Zhang; Jian, Fang; Zhaoji, Li

    2011-07-01

    A new lateral insulated-gate bipolar transistor with a controlled anode (CA-LIGBT) on silicon-on-insulator (SOI) substrate is reported. Benefiting from both the enhanced conductivity modulation effect and the high resistance controlled electron extracting path, CA-LIGBT has a faster turn-off speed and lower forward drop, and the trade-off between off-state and on-state losses is better than that of state-of-the-art 3-D NCA-LIGBT, which we presented earlier. As the simulation results show, the ratios of figure of merit (FOM) for CA-LIGBT compared to that of 3-D NCA-LIGBT and conventional LIGBT are 1.45: 1 and 59.53: 1, respectively. And, the new devices can be created by using additional silicon direct bonding (SDB). So, from the power efficiency point of view, the proposed CA-LIGBT is a promising device for use in power ICs.

  19. Development of Drop/Shock Test in Microelectronics and Impact Dynamic Analysis for Uniform Board Response

    NASA Astrophysics Data System (ADS)

    Kallolimath, Sharan Chandrashekar

    For the past several years, many researchers are constantly developing and improving board level drop test procedures and specifications to quantify the solder joint reliability performance of consumer electronics products. Predictive finite element analysis (FEA) by utilizing simulation software has become widely acceptable verification method which can reduce time and cost of the real-time test process. However, due to testing and metrological limitations it is difficult not only to simulate exact drop condition and capture critical measurement data but also tedious to calibrate the system to improve test methods. Moreover, some of the important ever changing factors such as board flexural rigidity, damping, drop height, and drop orientation results in non-uniform stress/strain distribution throughout the test board. In addition, one of the most challenging tasks is to quantify uniform stress and strain distribution throughout the test board and identify critical failure factors. The major contributions of this work are in the four aspects of the drop test in electronics as following. First of all, an analytical FEA model was developed to study the board natural frequencies and responses of the system with the consideration of dynamic stiffness, damping behavior of the material and effect of impact loading condition. An approach to find the key parameters that affect stress and strain distributions under predominate mode responses was proposed and verified with theoretical solutions. Input-G method was adopted to study board response behavior and cut boundary interpolation methods was used to analyze local model solder joint stresses with the development of global/local FEA model in ANSYS software. Second, no ring phenomenon during the drop test was identified theoretically when the test board was modeled as both discrete system and continuous system. Numerical analysis was then conducted by FEA method for detailed geometry of attached chips with solder-joints. No ring test conditions was proposed and verified for the current widely used JEDEC standard. The significance of impact loading parameters such as pulse magnitude, pulse duration, pulse shapes and board dynamic parameter such as linear hysteretic damping and dynamic stiffness were discussed. Third, Kirchhoff's plate theory by principle of minimum potential energy was adopted to develop the FEA formulation to consider the effect of material hysteretic damping for the currently used JEDEC board test and proposed no-ring response test condition. Fourth, a hexagonal symmetrical board model was proposed to address the uniform stress and strain distribution throughout the test board and identify the critical failure factors. Dynamic stress and strain of the hexagonal board model were then compared with standard JEDEC board for both standard and proposed no-ring test conditions. In general, this line of research demonstrates that advanced techniques of FEA analysis can provide useful insights concerning the optimal design of drop test in microelectronics.

  20. Assessment of inceptisols soil quality following long-term cropping in a calcareous environment.

    PubMed

    Rezapour, Salar; Samadi, A

    2012-03-01

    The combination of morphological, clay mineralogy, physicochemical, and fertilitical properties of inceptisols were compared for monitoring soil quality response following long-term agricultural activities. For this target, fifty-nine paired surface soils belonging to five subgroups of inceptisols from the major sugar beet growing area and the adjoining virgin lands were described, sampled, and analyzed. The soils were alkaline and calcareous as characterized by high pH, ranging from 7.2 to 8, and calcium carbonate equivalent, ranging from 60 to 300 g kg(-1). Following long-term sugar beet cultivation, morphological properties modifications were reflected as weakening of structure, hardening of consistency, and brightening of soil color. Although, the quantity of clay minerals did not significantly change through long-term cropping, some modifications in the XRD pattern of illite and smectite were observed in the cultivated soils compared to the adjoining virgin lands mainly as a result of potassium depletion. Without significant variation, sand content decreased by 4-55% and silt and clay increased by 3-22% and 2-15%, respectively, in the cultivated soils than to that of the virgin lands. Both negative and positive aspects of soil quality were reflected regarding soil chemical and fertilitical properties and the role of negative effects far exceeded the role of positive effects. Typic calcixerepts was known to be more degraded through a significant decrease (P ≤ 0.001) in mean value of soil organic carbon (a drop of 24%), total N (a drop of 23%), available K (a drop of 42%), exchangeable K (a drop of 45%), potassium adsorption ratio and potassium saturation ratio (a drop of 44% and 42%, respectively) and a significant increase (P ≤ 0.001) in EC (a rise of 53%). Soil quality index, calculated based on nine soil properties [coarse fragments, pH, SOC, total N, ESP, exchangeable cations (Ca, Mg, and K), and available phosphorus], indicated that 60% of the all soil types studied had negative changes, 20% had positive changes, and 20% produced no changes in soil heath.

  1. Prognostic and predictive value of TP53 mutations in node-positive breast cancer patients treated with anthracycline- or anthracycline/taxane-based adjuvant therapy: results from the BIG 02-98 phase III trial

    PubMed Central

    2012-01-01

    Abstract Introduction Pre-clinical data suggest p53-dependent anthracycline-induced apoptosis and p53-independent taxane activity. However, dedicated clinical research has not defined a predictive role for TP53 gene mutations. The aim of the current study was to retrospectively explore the prognosis and predictive values of TP53 somatic mutations in the BIG 02-98 randomized phase III trial in which women with node-positive breast cancer were treated with adjuvant doxorubicin-based chemotherapy with or without docetaxel. Methods The prognostic and predictive values of TP53 were analyzed in tumor samples by gene sequencing within exons 5 to 8. Patients were classified according to p53 protein status predicted from TP53 gene sequence, as wild-type (no TP53 variation or TP53 variations which are predicted not to modify p53 protein sequence) or mutant (p53 nonsynonymous mutations). Mutations were subcategorized according to missense or truncating mutations. Survival analyses were performed using the Kaplan-Meier method and log-rank test. Cox-regression analysis was used to identify independent predictors of outcome. Results TP53 gene status was determined for 18% (520 of 2887) of the women enrolled in BIG 02-98. TP53 gene variations were found in 17% (90 of 520). Nonsynonymous p53 mutations, found in 16.3% (85 of 520), were associated with older age, ductal morphology, higher grade and hormone-receptor negativity. Of the nonsynonymous mutations, 12.3% (64 of 520) were missense and 3.6% were truncating (19 of 520). Only truncating mutations showed significant independent prognostic value, with an increased recurrence risk compared to patients with non-modified p53 protein (hazard ratio = 3.21, 95% confidence interval = 1.740 to 5.935, P = 0.0002). p53 status had no significant predictive value for response to docetaxel. Conclusions p53 truncating mutations were uncommon but associated with poor prognosis. No significant predictive role for p53 status was detected. Trial registration ClinicalTrials.gov NCT00174655 PMID:22551440

  2. Usage of drip drops as stimuli in an auditory P300 BCI paradigm.

    PubMed

    Huang, Minqiang; Jin, Jing; Zhang, Yu; Hu, Dewen; Wang, Xingyu

    2018-02-01

    Recently, many auditory BCIs are using beeps as auditory stimuli, while beeps sound unnatural and unpleasant for some people. It is proved that natural sounds make people feel comfortable, decrease fatigue, and improve the performance of auditory BCI systems. Drip drop is a kind of natural sounds that makes humans feel relaxed and comfortable. In this work, three kinds of drip drops were used as stimuli in an auditory-based BCI system to improve the user-friendness of the system. This study explored whether drip drops could be used as stimuli in the auditory BCI system. The auditory BCI paradigm with drip-drop stimuli, which was called the drip-drop paradigm (DP), was compared with the auditory paradigm with beep stimuli, also known as the beep paradigm (BP), in items of event-related potential amplitudes, online accuracies and scores on the likability and difficulty to demonstrate the advantages of DP. DP obtained significantly higher online accuracy and information transfer rate than the BP ( p  < 0.05, Wilcoxon signed test; p  < 0.05, Wilcoxon signed test). Besides, DP obtained higher scores on the likability with no significant difference on the difficulty ( p  < 0.05, Wilcoxon signed test). The results showed that the drip drops were reliable acoustic materials as stimuli in an auditory BCI system.

  3. 40 CFR 53.64 - Test procedure: Static fractionator test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test procedure: Static fractionator test. 53.64 Section 53.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Performance Characteristics of Class II Equivalent Methods for PM2.5 § 53.64 Test procedure: Static...

  4. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  5. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  6. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  7. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  8. 40 CFR 53.64 - Test procedure: Static fractionator test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedure: Static fractionator test. 53.64 Section 53.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Performance Characteristics of Class II Equivalent Methods for PM2.5 § 53.64 Test procedure: Static...

  9. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  10. Size Distribution and Velocity of Ethanol Drops in a Rocket Combustor Burning Ethanol and Liquid Oxygen

    NASA Technical Reports Server (NTRS)

    Ingebo, Robert D.

    1961-01-01

    Single jets of ethanol were studied photomicrographically inside a rocket chamber as they broke up into sprays of drops which underwent simultaneous acceleration and vaporization with chemical reaction occurring in the surrounding combustion gas stream. In each rocket test-firing, liquid oxygen was used as the oxidant. Both drop velocity and drop size distribution data were obtained from photomicrographs of the ethanol drops taken with an ultra-high speed tracking camera developed at NASA, Lewis Research Center.

  11. Effect of swirler-mounted mixing venturi on emissions of flame-tube combustor using jet A fuel

    NASA Technical Reports Server (NTRS)

    Ercegovic, D. B.

    1979-01-01

    Six headplate modules in a flame-tube combustor were evaluated. Unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were measured for three types of fuel injectors both with and without a mixing venturi. Tests were conducted using jet A fuel at an inlet pressure of 0.69 megapascal, an inlet temperature of 478 K, and an isothermal static pressure drop of 3 percent. Oxides of nitrogen were reduced by over 50 percent with a mixing venturi with no performance penalties in either other gaseous emissions or pressure drop.

  12. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API Standard 620 and first placed in service after October 2, 2000, hydrostatic and pneumatic testing must be...

  13. Crash Simulation of a Vertical Drop Test of a Commuter-Class Aircraft

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.

    2004-01-01

    A finite element model of an ATR42-300 commuter-class aircraft was developed and a crash simulation was executed. Analytical predictions were correlated with data obtained from a 30-ft/s (9.14-m/s) vertical drop test of the aircraft. The purpose of the test was to evaluate the structural response of the aircraft when subjected to a severe, but survivable, impact. The aircraft was configured with seats, dummies, luggage, and other ballast. The wings were filled with 8,700 lb. (3,946 kg) of water to represent the fuel. The finite element model, which consisted of 57,643 nodes and 62,979 elements, was developed from direct measurements of the airframe geometry. The seats, dummies, luggage, fuel, and other ballast were represented using concentrated masses. The model was executed in LS-DYNA, a commercial code for performing explicit transient dynamic simulations. Predictions of structural deformation and selected time-history responses were generated. The simulation was successfully validated through extensive test-analysis correlation.

  14. Results of a M = 5.3 heat transfer test of the integrated vehicle using phase-change paint techniques on the 0.0175-scale model 56-OTS in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Marroquin, J.

    1985-01-01

    An experimental investigation was performed in the NASA/Ames Research Center 3.5-foot Hypersonic Wind Tunnel to obtain supersonic heat-distribution data in areas between the orbiter and external tank using phase-change paint techniques. The tests used Novamide SSV Model 56-OTS in the first and second-stage ascent configurations. Data were obtained at a nominal Mach number of 5.3 and a Reynolds number per foot of 5 x 10 to the 6th power with angles of attack of 0 deg, +/- 5 deg, and sideslip angles of 0 deg and +/- 5 deg.

  15. Does gymnastics practice improve vertical jump reliability from the age of 8 to 10 years?

    PubMed

    Marina, Michel; Torrado, Priscila

    2013-01-01

    The objective of this study was to confirm whether gymnastics practice from a young age can induce greater vertical jump reliability. Fifty young female gymnasts (8.84 ± 0.62 years) and 42 females in the control group (8.58 ± 0.92 years) performed the following jump tests on a contact mat: squat jump, countermovement jump, countermovement jump with arm swing and drop jump from heights of 40 and 60 cm. The two testing sessions had three trials each and were separated by one week. A 2 (groups) × 2 (sessions) × 3 (trials) repeated measures analysis of variance (ANOVA) and a test-retest correlation analysis were used to study the reliability. There was no systematic source of error in either group for non-plyometric jumps such as squat jump, countermovement jump, and countermovement jump with arm swing. A significant group per trial interaction revealed a learning effect in gymnasts' drop jumps from 40 cm height. Additionally, the test-retest correlation analysis and the higher minimum detectable error suggest that the quick drop jump technique was not fully consolidated in either group. At an introductory level of gymnastics and between the ages of 8-10 years, the condition of being a gymnast did not lead to conclusively higher reliability, aside from better overall vertical jump performance.

  16. Evaluation of EXPLOSAFE. Explosion Suppression System for Aircraft Fuel Tank Protection

    DTIC Science & Technology

    1980-07-01

    between the Baffles,4 after Test 142 66 Test 2: Batt at Mouth of Tail Cone Rotated 3 Degrees 143 67 Test 2: No Rotation of Sealant Anchored Batts in Nose...Data 85 16 One "G" Drop Test Data 87 17 Vent Icing Test Data 911 18 Slosh Rig Transducer Calibration 103 19 Slosh Rig Test Data - Dry Run without Test...airborne applications. xxix Even though the dry weight of the material is somewhat greater 𔃻 d than that of other e,.:plosion suppressant materials

  17. Vertical ridge augmentation with autogenous bone grafts 3 years after loading: resorbable barriers versus titanium-reinforced barriers. A randomized controlled clinical trial.

    PubMed

    Merli, Mauro; Lombardini, Francesco; Esposito, Marco

    2010-01-01

    To compare the efficacy of two different techniques for vertical bone regeneration at implant placement with particulated autogenous bone at 3 years after loading: resorbable collagen barriers supported by osteosynthesis plates and nonresorbable titanium-reinforced expanded polytetrafluoroethylene barriers. Twenty-two partially edentulous patients requiring vertical bone augmentation were randomly allocated to two treatment groups, each composed of 11 patients. Prosthetic and implant failures, complications, the amount of vertically regenerated bone, and peri-implant marginal bone levels were recorded by independent and blinded assessors. The implant site requiring the most vertical bone regeneration was selected in each patient for bone level assessment. The follow-up time ranged from provisional loading to 3 years after loading. Analysis of covariance and paired t tests were conducted to compare means at the .05 level of significance. No patient dropped out or was excluded at the 3-year follow-up. No prosthetic failures and no implant failures or complications occurred after loading. There was no statistically significant difference in bone loss between the two groups at either 1 year or 3 years. Both groups had gradually lost a statistically significant amount of peri-implant bone at 1 and 3 years (P < .05). After 3 years, patients treated with resorbable barriers had lost a mean of 0.55 mm of bone; patients who had received nonresorbable barriers showed a mean of 0.53 mm of bone loss. Up to 3 years after implant loading, no failures or complications occurred and peri-implant marginal bone loss was minimal. Vertically regenerated bone can be successfully maintained after functional loading.

  18. [Comparison of two kinds of artificial tears on the dry eye after phacoemulsification].

    PubMed

    You, R; Wang, J; Han, Y; Liu, L J; Wang, W Y

    2017-06-11

    Objective: To compare the curative effect of two different artificial tears on dry eye after phacoemulsification. Methods: Prospective randomized controlled clinical trial. From March to June in 2012, 102 patients (102 eyes) with age-related cataract were treated with phacoemulsification at Beijing Tongren Hospital, Capital University of Medical Sciences, and these eyes were randomly divided into blank group (group A ) 32 cases, treatment group 1 (group B) 35 cases and treatment group 2 (group C) 35 cases. Group A was treated with conventional antibiotics. Group B was sodium hyaluronate eye drop, group C was lipid-containing carbomer gel respectively. All patients finished a dry eye questionnaire called Ocular Surface Disease Index (OSDI), and Schimmer's test (SIt), break up time (BUT) and fluorescein staining (FL) tests were performed before surgery and at 7, 30 and 90 days after surgery respectively. Optometry were performed at 90 days after surgery. The χ(2) test was used to analyze the sex of the patients, and the age of the patients was analyzed by one-way ANOVA. Partial data in eye tests and in OSDI does not meet the normal distribution. Therefore, they were analyzed by Kruskal-Wallis H test. If significant difference existed, these data were then analyzed by independent sample Wilcoxon rank sum test. Results: Twelve patients were lost to visit within 3 months. A total of 90 patients were followed up for 90 days. The mean age of all patients was (69.5±9.5) years (46.0-89.0 years), 38 males and 64 females. There were 30 patients in Group A, group B and group C respectively. The prevalence of dry eye was 56. 7% (60/102). There was no significant difference among the three groups ( P> 0.05). OSDI questionnaire showed that OSDI score was significantly different among the three groups at 7, 30 and 90 days after operation ( H =9.89, 55.53, 45.43, P< 0.05). At 30 and 90 days after operation, the median OSDI scores were 12.50 and 10.42 in group C, respectively, which were better than those of group A scores 27.09 and 20. 8 ( Z=- 6.30, -5.94, P< 0.05), and were better than those of group B scores 17.71 and 13. 54 ( Z=- 3.40, -3.52, P< 0.05). At 90 days after operation, the median BUT of B and C treatment groups was 9. 00, which was better than that of group A (4.00). The difference was statistically significant ( H =21.51, P< 0.05), There was no significant difference between group B and group C ( Z=- 0.34, P> 0.05). Conclusion: The treatment of artificial tears with lipid composition in the early stage after phacoemulsification is beneficial to the improvement of postoperative symptoms and signs of dry eye. (Chin J Ophthalmol, 2017, 53: 445-450) .

  19. A User’s Guide to the SEVP (Stabilized Error Vector Propagation) Solver: An Efficient Direct Solver for Elliptic Partial Differential Equations

    DTIC Science & Technology

    1989-04-13

    19 5.3 The Solution, BSM2 , BSM3 . ...................................... 21 6. Description of test example...are modified for the boundary conditions. The sections on the preprocessor subroutine BSM1 and the solution subroutines BSM2 , BSM3 may be skipped by...interior row j = N-1 to the solution error C5 on the second row j = IE(2) of the last block, so that P3 = C5 R31 (5.18) 20 5.3 The Solution. BSM2

  20. 40 CFR 53.65 - Test procedure: Loading test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performing the test in § 53.62 (full wind tunnel test), § 53.63 (wind tunnel inlet aspiration test), or § 53... particle delivery system shall consist of a static chamber or a low velocity wind tunnel having a.... The mean velocity in the test section of the static chamber or wind tunnel shall not exceed 2 km/hr...

  1. A comparative evaluation of dried activated sludge and mixed dried activated sludge with rice husk silica to remove hydrogen sulfide

    PubMed Central

    2013-01-01

    The aim of this study was to investigate the effectiveness of dried activated sludge (DAS) and mixed dried activated sludge with rice husk silica (DAS & RHS) for removal of hydrogen sulfide (H2S). Two laboratory-scale filter columns (packed one litter) were operated. Both systems were operated under different conditions of two parameters, namely different inlet gas concentrations and different inlet flow rates. The DAS & RHS packed filter showed more than 99.96% removal efficiency (RE) with empty bed residence time (EBRT) of 45 to 90 s and 300 mg/L inlet concentration of H2S. However, the RE decreased to 96.87% with the EBRT of 30 s. In the same condition, the DAS packed filter showed 99.37% RE. Nonetheless, the RE was shown to have dropped to 82.09% with the EBRT of 30 s. The maximum elimination capacity (EC) was obtained in the DAS & RHS packed filter up to 52.32 g/m3h, with the RE of 96.87% and H2S mass loading rate of 54 g/m3h. The maximum EC in the DAS packed filter was obtained up to 44.33 g/m3h with the RE of 82.09% and the H2S mass loading rate of 54 g/m3h. After 53 days of operating time and 54 g/m3h of loading rates, the maximum pressure drop reached to 3.0 and 8.0 (mm H2O) for the DAS & RHS packed and DAS packed filters, respectively. Based on the findings of this study, the DAS & RHS could be considered as a more suitable packing material to remove H2S. PMID:23497048

  2. Initial puffing behaviors and subjective responses differ between an electronic nicotine delivery system and traditional cigarettes.

    PubMed

    Norton, Kaila J; June, Kristie M; O'Connor, Richard J

    2014-01-01

    Electronic nicotine delivery systems (ENDS) present an emerging issue for tobacco control and data on product use behaviors are limited. Participants (N = 38 enrolled; N = 16 compliant) completed three lab visits over 5 days and were asked to abstain from regular cigarettes for 72 hours in favor of ENDS (Smoke 51 TRIO - 3 piece, First Generation with 11 mg/ml filters). Lab visits included measurement of exhaled carbon monoxide (CO) and salivary cotinine concentration, questionnaire measures of regular cigarette craving after the 72 hour abstinence, and subjective product effects. Participants used a topography device to record puff volume, duration, flow rate, and inter-puff interval. Analyses revealed significant differences across products in puff count, average volume, total volume and inter-puff interval, with ENDS broadly showing a more intensive smoking pattern. Cigarette craving scores dropped significantly after smoking regular cigarettes, but not ENDS (p = .001), and subjective measures showed ENDS rated less favorably. CO boost, after ENDS use, decreased significantly (p < .001), and saliva cotinine significantly dropped between visits 1 and 3 (p < 0.001) after ENDS use relative to after cigarette smoking. For compliant and non-compliant participants, there was an average 82.0% [V1 - 16.1 cpd; V3 - 2.9 cpd] and average 73.9% [V1 - 20.3 cpd; V3 - 5.3 cpd] reduction in regular cigarette use per day during the ENDS trial period, respectively. The ENDS were smoked more intensively than own brand cigarettes, but delivered significantly less nicotineand were less satisfying. These findings have implications for the viability of certain ENDS as alternatives to cigarettes.

  3. Standardized Sample Preparation Using a Drop-on-Demand Printing Platform

    DTIC Science & Technology

    2013-05-07

    successful and robust methodology for energetic sample preparation. Keywords: drop-on-demand; inkjet printing; sample preparation OPEN ACCESS...on a similar length scale. Recently, drop-on-demand inkjet printing technology has emerged as an effective approach to produce test materials to...which most of the material is concentrated along the edges, samples prepared using drop-on-demand inkjet technology demonstrate excellent uniform

  4. Log-normal spray drop distribution...analyzed by two new computer programs

    Treesearch

    Gerald S. Walton

    1968-01-01

    Results of U.S. Forest Service research on chemical insecticides suggest that large drops are not as effective as small drops in carrying insecticides to target insects. Two new computer programs have been written to analyze size distribution properties of drops from spray nozzles. Coded in Fortran IV, the programs have been tested on both the CDC 6400 and the IBM 7094...

  5. Intravitreal injection anesthesia--comparison of different topical agents: a prospective randomized controlled trial.

    PubMed

    Yau, Gary L; Jackman, Christopher S; Hooper, Philip L; Sheidow, Tom G

    2011-02-01

    To compare the anesthetic effectiveness of 3 topical agents used for intravitreal injections. Randomized, triple-armed, double-blinded, prospective, single-centered trial in patients receiving intravitreal ranibizumab for neovascular age-related macular degeneration. Patients were randomized 1:1:1 to receive 0.5% tetracaine hydrochloride drops and a 4% lidocaine pledget (n = 31), 0.5% tetracaine hydrochloride drops alone (n = 31), or 4% cocaine (+ epinephrine 1/100,000) drops alone (n = 31). Patients were asked to score their pain experience using a visual analogue scale (VAS) immediately following and 15 minutes after their injection. The average of these scores was used as the primary outcome. The physician performing the procedure separately scored his perception of the patients' pain using the Wong-Baker FACES scale. Means of the averaged VAS pain score for Groups 1, 2, and 3 were: 19 (95% confidence interval [CI] 12-26), 21 (95% CI 13-29), and 21 (95% CI 16-27) respectively. Mean Wong-Baker pain scores for Groups 1, 2, and 3 were 1.9 (95% CI 1.3-2.6), 2.1 (95% CI 1.4-2.7), and 2.3 (95% CI 1.6-3.1) respectively. There was no significant difference (P = .549) between groups for average VAS pain score. Similarly, there was no significant difference (P = .790) for the physician-perceived pain score between groups. There was no clinical difference in patient pain experience between the 3 anesthetic options tested. The addition of a 4% lidocaine pledget offered no clinical advantage in pain relief compared to 0.5% tetracaine or 4% cocaine (+ epinephrine 1/100,000) drops alone. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Impact reduction through long-term intervention in recreational runners: midfoot strike pattern versus low-drop/low-heel height footwear.

    PubMed

    Giandolini, Marlène; Horvais, Nicolas; Farges, Yohann; Samozino, Pierre; Morin, Jean-Benoît

    2013-08-01

    Impact reduction has become a factor of interest in the prevention of running-related injuries such as stress fractures. Currently, the midfoot strike pattern (MFS) is thought as a potential way to decrease impact. The purpose was to test the effects of two long-term interventions aiming to reduce impact during running via a transition to an MFS: a foot strike retraining versus a low-drop/low-heel height footwear. Thirty rearfoot strikers were randomly assigned to two experimental groups (SHOES and TRAIN). SHOES progressively wore low-drop/low-heel height shoes and TRAIN progressively adopted an MFS, over a 3-month period with three 30-min running sessions per week. Measurement sessions (pre-training, 1, 2 and 3 months) were performed during which subjects were equipped with three accelerometers on the shin, heel and metatarsals, and ran for 15 min on an instrumented treadmill. Synchronized acceleration and vertical ground reaction force signals were recorded. Peak heel acceleration was significantly lower as compared to pre-training for SHOES (-33.5 ± 12.8 % at 2 months and -25.3 ± 18.8 % at 3 months, p < 0.001), and so was shock propagation velocity (-12.1 ± 9.3 %, p < 0.001 at 2 months and -11.3 ± 4.6 %, p < 0.05 at 3 months). No change was observed for TRAIN. Important inter-individual variations were noted in both groups and reported pains were mainly located at the shin and calf. Although it induced reversible pains, low-drop/low-heel height footwear seemed to be more effective than foot strike retraining to attenuate heel impact in the long term.

  7. Additional Results of Glaze Icing Scaling in SLD Conditions

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching

    2016-01-01

    New guidance of acceptable means of compliance with the super-cooled large drops (SLD) conditions has been issued by the U.S. Department of Transportation's Federal Aviation Administration (FAA) in its Advisory Circular AC 25-28 in November 2014. The Part 25, Appendix O is developed to define a representative icing environment for super-cooled large drops. Super-cooled large drops, which include freezing drizzle and freezing rain conditions, are not included in Appendix C. This paper reports results from recent glaze icing scaling tests conducted in NASA Glenn Icing Research Tunnel (IRT) to evaluate how well the scaling methods recommended for Appendix C conditions might apply to SLD conditions. The models were straight NACA 0012 wing sections. The reference model had a chord of 72 inches and the scale model had a chord of 21 inches. Reference tests were run with airspeeds of 100 and 130.3 knots and with MVD's of 85 and 170 microns. Two scaling methods were considered. One was based on the modified Ruff method with scale velocity found by matching the Weber number W (sub eL). The other was proposed and developed by Feo specifically for strong glaze icing conditions, in which the scale liquid water content and velocity were found by matching reference and scale values of the non-dimensional water-film thickness expression and the film Weber number W (sub ef). All tests were conducted at 0 degrees angle of arrival. Results will be presented for stagnation freezing fractions of 0.2 and 0.3. For non-dimensional reference and scale ice shape comparison, a new post-scanning ice shape digitization procedure was developed for extracting 2-dimensional ice shape profiles at any selected span-wise location from the high fidelity 3-dimensional scanned ice shapes obtained in the IRT.

  8. Additional Results of Glaze Icing Scaling in SLD Conditions

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching

    2016-01-01

    New guidance of acceptable means of compliance with the super-cooled large drops (SLD) conditions has been issued by the U.S. Department of Transportation's Federal Aviation Administration (FAA) in its Advisory Circular AC 25-28 in November 2014. The Part 25, Appendix O is developed to define a representative icing environment for super-cooled large drops. Super-cooled large drops, which include freezing drizzle and freezing rain conditions, are not included in Appendix C. This paper reports results from recent glaze icing scaling tests conducted in NASA Glenn Icing Research Tunnel (IRT) to evaluate how well the scaling methods recommended for Appendix C conditions might apply to SLD conditions. The models were straight NACA 0012 wing sections. The reference model had a chord of 72 in. and the scale model had a chord of 21 in. Reference tests were run with airspeeds of 100 and 130.3 kn and with MVD's of 85 and 170 micron. Two scaling methods were considered. One was based on the modified Ruff method with scale velocity found by matching the Weber number WeL. The other was proposed and developed by Feo specifically for strong glaze icing conditions, in which the scale liquid water content and velocity were found by matching reference and scale values of the nondimensional water-film thickness expression and the film Weber number Wef. All tests were conducted at 0 deg AOA. Results will be presented for stagnation freezing fractions of 0.2 and 0.3. For nondimensional reference and scale ice shape comparison, a new post-scanning ice shape digitization procedure was developed for extracting 2-D ice shape profiles at any selected span-wise location from the high fidelity 3-D scanned ice shapes obtained in the IRT.

  9. 14 CFR 23.725 - Limit drop tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...

  10. 14 CFR 23.725 - Limit drop tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...

  11. 14 CFR 23.725 - Limit drop tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...

  12. 14 CFR 23.725 - Limit drop tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... assumed wing lift to the airplane weight, but not more than 0.667. (c) The limit inertia load factor must... test. (e) The limit inertia load factor must be determined from the drop test in paragraph (b) of this... paragraph (e) may not be more than the limit inertia load factor used in the landing conditions in § 23.473...

  13. Flow structure of natural dehumidification over a horizontal finned-tube

    NASA Astrophysics Data System (ADS)

    Hirbodi, Kamran; Yaghoubi, Mahmood

    2016-08-01

    In the present study, structure of water drops formation, growth, coalescence and departure over a horizontal finned-tube during natural dehumidification is investigated experimentally. Starting time of repelling the drops as well as heat transfer rate and the rate of dripping condensates in quasi-steady-state conditions are presented. Furthermore, cold airflow pattern around the horizontal finned-tube is visualized by using smoke generation scheme during natural dehumidification process. The finned-tube has a length of 300 mm, and inner and outer fin diameters, fin thickness and fin spacing are 25.4, 56, 0.4 and 2 mm, respectively. The tests are conducted in an insulated control room with dimensions of 5.8 m × 3 m × 4 m. Ambient air temperature, relative humidity and fin base temperature are selected from 25 to 35 °C, from 40 to 70 % and from 4 to 8 °C, respectively. Observations show that natural condensation from humid air over the test case is completely dropwise. Droplets only form on the edge of the fin and lateral fin surfaces remain almost dry. Dehumidification process over the tested finned-tube is divided into four stages; nucleation, formation, growth and departure of drops. It is also observed that the condensate inundation leaves the tube bottom in the form of droplets. Smoke visualization depicts that humid airflows downward around the cold finned-tube surface without noticeable turbulence and separation in the initial stages of dehumidification process. But the airflow has some disturbances in the intermediate stage and especially during drop departure on the edge of the fins.

  14. Comparison between Pludix and impact/optical disdrometers during rainfall measurement campaigns

    NASA Astrophysics Data System (ADS)

    Caracciolo, Clelia; Prodi, Franco; Uijlenhoet, Remko

    2006-11-01

    The performances of two couples of disdrometers based on different measuring principles are compared: a classical Joss-Waldvogel disdrometer and a recently developed device, called the Pludix tested in Ferrara, Italy, and Pludix and the two-dimensional video disdrometer (2DVD) tested in Cabauw, The Netherlands. First, the measuring principles of the different instruments are presented and compared. Secondly, the performances of the two pairs of disdrometers are analysed by comparing their rain amounts with nearby tipping bucket rain gauges and the inferred drop size distributions. The most important rainfall integral parameters (e.g. rain rate and radar reflectivity) and drop size distribution parameters are also analysed and compared. The data set for Ferrara comprises 13 rainfall events, with a total of 20 mm of rainfall and a maximum rain rate of 4 mm h - 1 . The data set for Cabauw consists of 9 events, with 25-50 mm of rainfall and a maximum rain rate of 20-40 mm h - 1 . The Pludix tends to underestimate slightly the bulk rainfall variables in less intense events, whereas it tends to overestimate with respect to the other instruments in heavier events. The correspondence of the inferred drop size distributions with those measured by the other disdrometers is reasonable, particularly with the Joss-Waldvogel disdrometer. Considering that the Pludix is still in a calibration and testing phase, the reported results are encouraging. A new signal inversion algorithm, which will allow the detection of rain drops throughout the entire diameter interval between 0.3 and 7.0 mm, is under development.

  15. Student Drop Tower Competitions: Dropping In a Microgravity Environment (DIME) and What If No Gravity? (WING)

    NASA Technical Reports Server (NTRS)

    Hall, Nancy R.; Stocker, Dennis P.; DeLombard, Richard

    2011-01-01

    This paper describes two student competition programs that allow student teams to conceive a science or engineering experiment for a microgravity environment. Selected teams design and build their experimental hardware, conduct baseline tests, and ship their experiment to NASA where it is operated in the 2.2 Second Drop Tower. The hardware and acquired data is provided to the teams after the tests are conducted so that the teams can prepare their final reports about their findings.

  16. Visual function assessment in simulated real-life situations in patients with age-related macular degeneration compared to normal subjects.

    PubMed

    Barteselli, G; Gomez, M L; Doede, A L; Chhablani, J; Gutstein, W; Bartsch, D-U; Dustin, L; Azen, S P; Freeman, W R

    2014-10-01

    To evaluate visual function variations in eyes with age-related macular degeneration (AMD) compared to normal eyes under different light/contrast conditions using a time-dependent visual acuity testing instrument, the Central Vision Analyzer (CVA). Overall, 37 AMD eyes and 35 normal eyes were consecutively tested with the CVA after assessing best-corrected visual acuity (BCVA) using ETDRS charts. The CVA established visual thresholds for three mesopic environments (M1 (high contrast), M2 (medium contrast), and M3 (low contrast)) and three backlight-glare environments (G1 (high contrast, equivalent to ETDRS), G2 (medium contrast), and G3 (low contrast)) under timed conditions. Vision drop across environments was calculated, and repeatability of visual scores was determined. BCVA significantly reduced with decreasing contrast in all eyes. M1 scores for BCVA were greater than M2 and M3 (P<0.001); G1 scores were greater than G2 and G3 (P<0.01). BCVA dropped more in AMD eyes than in normal eyes between M1 and M2 (P=0.002) and between M1 and M3 (P=0.003). In AMD eyes, BCVA was better using ETDRS charts compared to G1 (P<0.001). The drop in visual function between ETDRS and G1 was greater in AMD eyes compared to normal eyes (P=0.004). Standard deviations of test-retest ranged from 0.100 to 0.139 logMAR. The CVA allowed analysis of the visual complaints that AMD patients experience with different lighting/contrast time-dependent conditions. BCVA changed significantly under different lighting/contrast conditions in all eyes, however, AMD eyes were more affected by contrast reduction than normal eyes. In AMD eyes, timed conditions using the CVA led to worse BCVA compared to non-timed ETDRS charts.

  17. Super p53 for Treatment of Ovarian Cancer

    DTIC Science & Technology

    2017-09-01

    System 3, Clontech) containing wt-p53, p53-CC, and ZsGreen (control) were made. Ad-ZsGreen was tested in ID8 cells, which showed very high expression...views, opinions and/or findings contained in this report are those of the author(s) and should not be construed as an official Department of the Army...MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT Approved for Public Release; Distribution Unlimited 13. SUPPLEMENTARY NOTES 14

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. George L Mesina

    Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing. RELAP5-3D must perform in a manner consistent with previous code versions with backward compatibility for the sake of the users. Thus file operations, code termination, input and output must remain consistent in form and content while adding appropriate new files, input and output as new features are developed. As computermore » hardware, operating systems, and other software change, RELAP5-3D must adapt and maintain performance. The code must be thoroughly tested to ensure that it continues to perform robustly on the supported platforms. The coding must be written in a consistent manner that makes the program easy to read to reduce the time and cost of development, maintenance and error resolution. The programming guidelines presented her are intended to institutionalize a consistent way of writing FORTRAN code for the RELAP5-3D computer program that will minimize errors and rework. A common format and organization of program units creates a unifying look and feel to the code. This in turn increases readability and reduces time required for maintenance, development and debugging. It also aids new programmers in reading and understanding the program. Therefore, when undertaking development of the RELAP5-3D computer program, the programmer must write computer code that follows these guidelines. This set of programming guidelines creates a framework of good programming practices, such as initialization, structured programming, and vector-friendly coding. It sets out formatting rules for lines of code, such as indentation, capitalization, spacing, etc. It creates limits on program units, such as subprograms, functions, and modules. It establishes documentation guidance on internal comments. The guidelines apply to both existing and new subprograms. They are written for both FORTRAN 77 and FORTRAN 95. The guidelines are not so rigorous as to inhibit a programmer’s unique style, but do restrict the variations in acceptable coding to create sufficient commonality that new readers will find the coding in each new subroutine familiar. It is recognized that this is a “living” document and must be updated as languages, compilers, and computer hardware and software evolve.« less

  19. Research on the F/A-18E/F Using a 22%-Dynamically-Scaled Drop Model

    NASA Technical Reports Server (NTRS)

    Croom, M.; Kenney, H.; Murri, D.; Lawson, K.

    2000-01-01

    Research on the F/A-18E/F configuration was conducted using a 22%-dynamically-scaled drop model to study flight dynamics in the subsonic regime. Several topics were investigated including longitudinal response, departure/spin resistance, developed spins and recoveries, and the failing leaf mode. Comparisons to full-scale flight test results were made and show the drop model strongly correlates to the airplane even under very dynamic conditions. The capability to use the drop model to expand on the information gained from full-scale flight testing is also discussed. Finally, a preliminary analysis of an unusual inclined spinning motion, dubbed the "cartwheel", is presented here for the first time.

  20. Changes in Indirect Markers of Muscle Damage and Tendons After Daily Drop Jumping Exercise with Rapid Load Increase

    PubMed Central

    Paleckis, Vidas; Mickevičius, Mantas; Snieckus, Audrius; Streckis, Vytautas; Pääsuke, Mati; Rutkauskas, Saulius; Steponavičiūtė, Rasa; Skurvydas, Albertas; Kamandulis, Sigitas

    2015-01-01

    The aim of this study was to assess changes in indirect markers of muscle damage and type I collagen degradation, as well as, patellar and Achilles tendon morphological differences during nine daily drop-jumps sessions with constant load alternated with rapid increases in load to test the hypothesis that frequent drop-jump training results in negative muscular and tendon adaptation. Young men (n = 9) performed daily drop jump workouts with progression every 3 days in terms of number of jumps, platform height and squat amplitude. Voluntary and electrically evoked knee extensor torque, muscle soreness, blood plasma creatine kinase (CK) activity and carboxyterminal cross-linked telopeptide (ICTP), patellar and Achilles tendon thickness and cross-sectional area (CSA) were assessed at different time points during the training period and again on days 1, 3, 10 and 17 after the training. The findings were as follows: (1) steady decline in maximal muscle strength with major recovery within 24 hours after the first six daily training sessions; (2) larger decline in electrically induced muscle torque and prolonged recovery during last three training sessions; (3) increase in patellar and Achilles tendons CSA without change in thickness towards the end of training period; (4) increase in jump height but not in muscle strength after whole training period. Our findings suggest that frequent drop-jump sessions with constant load alternated with rapid increases in load do not induce severe muscle damage or major changes in tendons, nonetheless, this type of loading is not advisable for muscle strength improvement. Key points Frequent drop jump training induces activation mode dependent muscle torque depression late in the training period. No significant changes in the thickness of patellar and Achilles tendons are observed during frequent training, while CSA increases towards the end of training period. Longitudinal effect for jump height but not for muscle strength is evident after the whole training period. PMID:26664280

  1. The challenge of comprehensively mapping children's health in a nation-wide health survey: design of the German KiGGS-Study.

    PubMed

    Kurth, Bärbel-Maria; Kamtsiuris, Panagiotis; Hölling, Heike; Schlaud, Martin; Dölle, Rüdiger; Ellert, Ute; Kahl, Heidrun; Knopf, Hiltraud; Lange, Michael; Mensink, Gert Bm; Neuhauser, Hannelore; Rosario, Angelika Schaffrath; Scheidt-Nave, Christa; Schenk, Liane; Schlack, Robert; Stolzenberg, Heribert; Thamm, Michael; Thierfelder, Wulf; Wolf, Ute

    2008-06-04

    From May 2003 to May 2006, the Robert Koch Institute conducted the German Health Interview and Examination Survey for Children and Adolescents (KiGGS). Aim of this first nationwide interview and examination survey was to collect comprehensive data on the health status of children and adolescents aged 0 to 17 years. Participants were enrolled in two steps: first, 167 study locations (sample points) were chosen; second, subjects were randomly selected from the official registers of local residents. The survey involved questionnaires filled in by parents and parallel questionnaires for children aged 11 years and older, physical examinations and tests, and a computer assisted personal interview performed by study physicians. A wide range of blood and urine testing was carried out at central laboratories. A total of 17 641 children and adolescents were surveyed - 8985 boys and 8656 girls. The proportion of sample neutral drop-outs was 5.3%. The response rate was 66.6%. The response rate showed little variation between age groups and sexes, but marked variation between resident aliens and Germans, between inhabitants of cities with a population of 100 000 or more and sample points with fewer inhabitants, as well as between the old West German states and the former East German states. By analysing the short non-responder questionnaires it was proven that the collected data give comprehensive and nationally representative evidence on the health status of children and adolescents aged 0 to 17 years.

  2. Desire for female sterilization among women wishing to limit births in rural Rakai, Uganda.

    PubMed

    Lutalo, Tom; Gray, Ron; Mathur, Sanyukta; Wawer, Maria; Guwatudde, David; Santelli, John; Nalugoda, Fred; Makumbi, Fredrick

    2015-11-01

    Uganda has an unmet need for family planning of 34% and a total fertility rate of 6.2. We assessed the desire for female sterilization among sexually active women who wanted to stop childbearing in rural Rakai district, Uganda. 7192 sexually active women enrolled in a community cohort between 2002 and 2008 were asked about fertility intentions. Those stating that they did not want another child (limiters) were asked whether they would be willing to accept female sterilization, if available. Trends in desire for sterilization were determined by chi-square test for trend, and Modified Poisson regression was used to estimate prevalence rate ratios and 95% confidence intervals of the associations between desire for sterilization and socio-demographic characteristics and HIV status. From 2002 to 2008, the proportion of limiters dropped (from 47.2% to 43.7%; p<.01). Use of pills and injectables among limiters significantly increased, 38.9% to 50.3% (p<.0001), while use of intrauterine devices and implants declined from 3.3% to 1.7% (p<0.001). The desire for sterilization significantly increased from 54.2% to 63.1% (p<0.0001), and this was consistently higher among the HIV-positive (63.6-70.9%, p<0.01) than HIV-negative women (53.3-61.2%, p<0.0001). Factors significantly associated with the desire for sterilization included higher number of living children (>=3), being HIV-infected and having received HIV counseling and testing. There is latent and growing desire for sterilization in this population. Our findings suggest a need to increase permanent contraception services for women who want to limit childbearing in this setting. A large unmet need for permanent female contraception services exists in Uganda. Efforts to increase the method mix by increasing permanent contraception services could reduce fertility rates and undesired births. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Molecular characterization of Cryptococcus neoformans isolated from the environment in Beijing, China.

    PubMed

    Dou, Hongtao; Wang, Huizhu; Xie, Shaowei; Chen, Xinxin; Xu, Zhipeng; Xu, Yingchun

    2017-10-01

    The molecular type of environmental Cryptococcus neoformans in Beijing was not clear. Our study aims to reveal the molecular characterization of C. neoformans complex from environment in Beijing, China. A total of 435 samples of pigeon droppings from 11 different homes in Beijing were collected from August to November in 2015. Pigeon droppings were inoculated onto caffeic acid cornmeal agar (CACA) to screen C. neoformans complex. Bruker Biotyper matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was performed for species identification. Serotype and mating type was determined by specific primers. Restriction fragment length polymorphisms of URA5 (URA5-RFLP) were applied to genotype. Multi-locus sequence typing (MLST) was done for further identification and sequence type (ST) determination. Altogether, 81 isolates of C. neoformans AFLP1/VNI were recognized from 435 pigeon droppings in this study. The positive rate for C. neoformans AFLP1/VNI from pigeon droppings in different homes varied from 5.0% to 52.6%, the average was 20.2%. All of these cryptococcal strains were serotype A, MATα. They were genotyped as VNI by URA5-RFLP and were confirmed by MLST. No other molecular types of C. neoformans and Cryptococcus gattii isolates were isolated. Their STs were identified as ST 31 (n = 54, 66.7%), followed by ST 53 (n = 10), ST 191 (n = 8), ST 5 (n = 5), ST 57 (n = 3), and ST 38 (n = 1). We concluded that not only clinical but also environmental isolates of C. neoformans need to be investigated more deeply and more extensively. The virulence difference between ST 5 and ST 31 need to be explored in the future. © The Author 2017. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Comparison of the Dichotomous and Polychotomous Quantal Response Models.

    DTIC Science & Technology

    1983-12-01

    containers are submitted to a drop height test, the response is "broken" or "not broken" . In drug testing, if the houseflies are exposed to a...particular insecticide, the number of houseflies that are either dead or alive can be observed. Usually, the tolerance distribution assumes the form of a...01,02,...,0s. In the housefly example, for a - 3. 01 = dead, 02 = moribund, 03 - alive. For s > 3, the 0 i’s represent decreasing degrees of

  5. Advances in high-power 9XXnm laser diodes for pumping fiber lasers

    NASA Astrophysics Data System (ADS)

    Skidmore, Jay; Peters, Matthew; Rossin, Victor; Guo, James; Xiao, Yan; Cheng, Jane; Shieh, Allen; Srinivasan, Raman; Singh, Jaspreet; Wei, Cailin; Duesterberg, Richard; Morehead, James J.; Zucker, Erik

    2016-03-01

    A multi-mode 9XXnm-wavelength laser diode was developed to optimize the divergence angle and reliable ex-facet power. Lasers diodes were assembled into a multi-emitter pump package that is fiber coupled via spatial and polarization multiplexing. The pump package has a 135μm diameter output fiber that leverages the same optical train and mechanical design qualified previously. Up to ~ 270W CW power at 22A is achieved at a case temperature ~ 30ºC. Power conversion efficiency is 60% (peak) that drops to 53% at 22A with little thermal roll over. Greater than 90% of the light is collected at < 0.12NA at 16A drive current that produces 3.0W/(mm-mr)2 radiance from the output fiber.

  6. Scanning drop sensor

    DOEpatents

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  7. Surface tension propellant control for Viking 75 Orbiter

    NASA Technical Reports Server (NTRS)

    Dowdy, M. W.; Hise, R. E.; Peterson, R. G.; Debrock, S. C.

    1976-01-01

    The paper describes the selection, development and qualification of the surface tension system and includes results of low-g drop tower tests of scale models, 1-g simulation tests of low-g large ullage settling and liquid withdrawal, structural qualification tests, and propellant surface tension/contact angle studies. Subscale testing and analyses were used to evaluate the ability of the system to maintain or recover the desired propellant orientation following possible disturbances during the Viking mission. This effort included drop tower tests to demonstrate that valid wick paths exist for moving any displaced propellant back over the tank outlet. Variations in surface tension resulting from aging, temperature, and lubricant contamination were studied and the effects of surface finish, referee fluid exposure, aging, and lubricant contamination on contact angle were assessed. Results of movies of typical subscale drop tower tests and full scale slosh tests are discussed.

  8. Load and dynamic assessment of B-52B-008 carrier aircraft for finned configuration 1 space shuttle solid rocket booster deceleration subsystem drop test vehicle. Volume 4: Pylon load data

    NASA Technical Reports Server (NTRS)

    Quade, D. A.

    1978-01-01

    The pylon loading at the drop test vehicle and wing interface attack points is presented. The loads shown are determined using a stiffness method, which assumes the side stiffness of the forward hook guide and the fore and aft stiffness of each drag pin to be equal. The net effect of this assumption is that the forward hook guide reacts approximately 96% of the drop test vehicle yawing moment. For a comparison of these loads to previous X-15 analysis design loadings, see Volume 1 of this document.

  9. 40 CFR 53.43 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test procedures. 53.43 Section 53.43... PM10 § 53.43 Test procedures. (a) Sampling effectiveness—(1) Technical definition. The ratio (expressed... or filters to the mass concentration of particles of the same size approaching the sampler. (2) Test...

  10. 40 CFR 53.43 - Test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test procedures. 53.43 Section 53.43... PM10 § 53.43 Test procedures. (a) Sampling effectiveness—(1) Technical definition. The ratio (expressed... or filters to the mass concentration of particles of the same size approaching the sampler. (2) Test...

  11. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    DTIC Science & Technology

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  12. Adsorptive performance of MOF nanocomposite for methylene blue and malachite green dyes: Kinetics, isotherm and mechanism.

    PubMed

    Alqadami, Ayoub Abdullah; Naushad, Mu; Alothman, Z A; Ahamad, Tansir

    2018-06-06

    In the present study, Fe 3 O 4 @AMCA-MIL-53(Al) nanocomposite was utilized for the adsorptive removal of highly toxic MB and MG dyes from aqueous environment. The batch adsorption tests were performed at different contact time, pH, Fe 3 O 4 @AMCA-MIL-53(Al) dose, initial concentration of dyes and temperature. The maximum adsorption capacity of MB and MG dyes onto of Fe 3 O 4 @AMCA-MIL-53(Al) using Langmuir equation was 1.02 and 0.90 m mol/g, respectively. The isotherm and kinetic studies revealed that adsorption data were well fitted to Langmuir isotherm and pseudo-first-order kinetics models. Various thermodynamic parameters were also calculated and interpreted. The positive and negative values of ΔH° and ΔG° indicated that the adsorption was endothermic and spontaneous, respectively. The adsorptive binding of MB and MG on Fe 3 O 4 @AMCA-MIL53(Al) nanocomposite was directed by carboxylate and amide groups through electrostatic interaction, π-π interaction and hydrogen bonding. The desorption of both dyes from Fe 3 O 4 @AMCA-MIL-53(Al) was also performed using mixed solution of 0.01 M HCl/ethanol. Thus, we conclude that the Fe 3 O 4 @AMCA-MIL-53(Al) was an outstanding material for the removal of dyes from aqueous environment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Characterisation of the p53 pathway in cell lines established from TH-MYCN transgenic mouse tumours.

    PubMed

    Chen, Lindi; Esfandiari, Arman; Reaves, William; Vu, Annette; Hogarty, Michael D; Lunec, John; Tweddle, Deborah A

    2018-03-01

    Cell lines established from the TH-MYCN transgenic murine model of neuroblastoma are a valuable preclinical, immunocompetent, syngeneic model of neuroblastoma, for which knowledge of their p53 pathway status is important. In this study, the Trp53 status and functional response to Nutlin-3 and ionising radiation (IR) were determined in 6 adherent TH-MYCN transgenic cell lines using Sanger sequencing, western blot analysis and flow cytometry. Sensitivity to structurally diverse MDM2 inhibitors (Nutlin-3, MI-63, RG7388 and NDD0005) was determined using XTT proliferation assays. In total, 2/6 cell lines were Trp53 homozygous mutant (NHO2A and 844MYCN+/+) and 1/6 (282MYCN+/-) was Trp53 heterozygous mutant. For 1/6 cell lines (NHO2A), DNA from the corresponding primary tumour was found to be Trp53 wt. In all cases, the presence of a mutation was consistent with aberrant p53 signalling in response to Nutlin-3 and IR. In comparison to TP53 wt human neuroblastoma cells, Trp53 wt murine control and TH-MYCN cell lines were significantly less sensitive to growth inhibition mediated by MI-63 and RG7388. These murine Trp53 wt and mutant TH-MYCN cell lines are useful syngeneic, immunocompetent neuroblastoma models, the former to test p53-dependent therapies in combination with immunotherapies, such as anti-GD2, and the latter as models of chemoresistant relapsed neuroblastoma when aberrations in the p53 pathway are more common. The spontaneous development of Trp53 mutations in 3 cell lines from TH-MYCN mice may have arisen from MYCN oncogenic driven and/or ex vivo selection. The identified species-dependent selectivity of MI-63 and RG7388 should be considered when interpreting in vivo toxicity studies of MDM2 inhibitors.

  14. MICROSTRUCTURAL AND MECHANICAL CHARACTERIZATION OF 2-D AND 3-D SiC/SiNC CERAMIC MATRIX COMPOSITES

    DTIC Science & Technology

    2018-02-23

    48 5.2 Residual Strength of Test Specimens Reaching Run -Out ...........................................48 5.3 Fracture...46 Table 10. Residual Strength Tension Test Results for Creep Rupture Specimens Reaching Run - Out...Residual Strength Tension Test Results for Fatigue Specimens Reaching Run -Out . 49 vii Distribution Statement A. Approved for public release

  15. Experimental and numerical study of drill bit drop tests on Kuru granite

    NASA Astrophysics Data System (ADS)

    Fourmeau, Marion; Kane, Alexandre; Hokka, Mikko

    2017-01-01

    This paper presents an experimental and numerical study of Kuru grey granite impacted with a seven-buttons drill bit mounted on an instrumented drop test machine. The force versus displacement curves during the impact, so-called bit-rock interaction (BRI) curves, were obtained using strain gauge measurements for two levels of impact energy. Moreover, the volume of removed rock after each drop test was evaluated by stereo-lithography (three-dimensional surface reconstruction). A modified version of the Holmquist-Johnson-Cook (MHJC) material model was calibrated using Kuru granite test results available from the literature. Numerical simulations of the single drop tests were carried out using the MHJC model available in the LS-DYNA explicit finite-element solver. The influence of the impact energy and additional confining pressure on the BRI curves and the volume of the removed rock is discussed. In addition, the influence of the rock surface shape before impact was evaluated using two different mesh geometries: a flat surface and a hyperbolic surface. The experimental and numerical results are compared and discussed in terms of drilling efficiency through the mechanical specific energy. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  16. Properties of Controlled Low Strength Material with Circulating Fluidized Bed Combustion Ash and Recycled Aggregates

    PubMed Central

    Weng, Tsai-Lung; Cheng, An; Chao, Sao-Jeng; Hsu, Hui-Mi

    2018-01-01

    This study aims to investigate the effect of adding circulating fluidized bed combustion (CFBC) ash, desulfurization slag, air-cooled blast-furnace slag and coal bottom ash to the controlled low-strength material (CLSM). Test methods include slump flow test, ball drop test, water soluble chloride ion content measurement, compressive strength and length change measurement. The results show that (1) the use of CFBC hydration ash with desulfurization slag of slump flow is the best, and the use of CFBC hydration ash with coal bottom ash and slump flow is the worst; (2) CFBC hydration ash with desulfurization slag and chloride ion content is the highest; (3) 24 h ball drop test (diameter ≤ 76 mm), and test results are 70 mm to 76 mm; (4) CFBC hydration ash with desulfurization slag and compression strength is the highest, with the coal bottom ash being the lowest; increase of CFBC hydration ash can reduce compressive strength; and (5) the water-quenched blast furnace slag and CFBC hydration ash would expand, which results in length changes of CLSM specimens. PMID:29724055

  17. Effect of External Pressure Drop on Loop Heat Pipe Operating Temperature

    NASA Technical Reports Server (NTRS)

    Jentung, Ku; Ottenstein, Laura; Rogers, Paul; Cheung, Kwok; Obenschain, Arthur F. (Technical Monitor)

    2002-01-01

    This paper discusses the effect of the pressure drop on the operating temperature in a loop heat pipe (LHP). Because the evaporator and the compensation chamber (CC) both contain two-phase fluid, a thermodynamic constraint exists between the temperature difference and the pressure drop for these two components. As the pressure drop increases, so will the temperature difference. The temperature difference in turn causes an increase of the heat leak from the evaporator to the CC, resulting in a higher CC temperature. Furthermore, the heat leak strongly depends on the vapor void fraction inside the evaporator core. Tests were conducted by installing a valve on the vapor line so as to vary the pressure drop, and by charging the LHP with various amounts of fluid. Test results verify that the LHP operating temperature increases with an increasing differential pressure, and the temperature increase is a strong function of the fluid inventory in the loop.

  18. [Stability of physical state on compound hawthorn dropping pills].

    PubMed

    Zhang, Wei; Chen, Hong-Yan; Jiang, Jian-Lan

    2008-11-01

    To evaluate the stability of physical state with accelerate test and dropping in process before and after on compound hawthorn dropping pills. Scanning electron microscope, TG-DTA, FT-IR and XRD were used. The active components presented amorphous, tiny crystal and molecular state in dropping pills, and it had no obvious reaction between PEG 4000 and active components. With time prolonging, a little of active components changed from amorphous state to tiny crystal or molecular state. Solid dispersion improved the stability and dissolution of compound hawthorn dropping pills.

  19. Association Between the Lower Extremity Deep Venous Thrombosis, the Warfarin Maintenance Dose, and CYP2C9*3, CYP2D6*10, and CYP3A5*3 Genetic Polymorphisms: A Case-Control Study.

    PubMed

    Ju, Shang; Gao, Yu; Cao, Xin; Zhang, Xiao-Fu; Yan, Cheng-Cheng; Liu, Feng-Tong

    2017-09-01

    This study explored the association between the CYP2C9*3/CYP2D6*10/CYP3A5*3 genetic polymorphisms with lower extremity deep venous thrombosis (LEDVT) and the warfarin maintenance dose. Five hundred thirty-six patients who were pathologically diagnosed with LEDVT after surgery were included in the LEDVT group. At the same time, 540 patients without LEDVT who underwent surgery were recruited as the control group. Patients were given warfarin at an initial dose of 2.5-3.0 mg. Blood samples were collected to detect the initial and stable international normalized ratio (INR) values. The warfarin maintenance dose was obtained if the INR remained within a range of 2.0-3.0 for 3 consecutive days. The genotype distribution and haplotype analysis of the CYP2C9*3/CYP2D6*10/CYP3A5*3 alleles were analyzed using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) testing and SHEsis software, respectively. Logistic regression analysis was used to analyze the risk and protective factors for LEDVT. The A/G genotypes, G/G genotypes, and G allele of CYP3A5*3 in the LEDVT group were observed with increased frequency compared with the control group. The LEDVT group displayed a higher ACG haplotype frequency, and lower ACA and ATA haplotype frequencies than the control group. Age, diabetes, low-density lipoprotein, CYP3A5*3 and the ACG haplotype were independent risk factors for LEDVT. High-density lipoprotein and the ACA haplotype were independent protective factors for LEDVT. The genotype distributions of the CYP2C9*3, CYP2D6*10, and CYP3A5*3 genetic polymorphisms were associated with the warfarin maintenance dose. The CYP3A5*3 genetic polymorphism may be an important risk factor for LEDVT. Moreover, CYP2C9*3, CYP2D6*10, and CYP3A5*3 are associated with the warfarin maintenance dose.

  20. Chemotherapy of Leishmaniasis.

    DTIC Science & Technology

    1978-12-01

    differential centrifugation. Rabbit blood agar slopes are seeded with a drop of the resultant amastigote suspension, 200 units/ml penicillin and 2 0pg/ml...visceral 644 220 Hendricks Man cutaneous 645 219 Man India visceral 646 234 Dog Spain cutaneous? 647 648 LN1 58 Murray Man Panama cutaneous 649 WR168...Calcutta School of Tropical Medicine, India 52 Dr. J. P. Farrell, Rutgers State University, New Jersey, USA 53 Dr. L. Hendricks , Walter Reed Army Institute

Top