Dry sliding wear behavior of Al 2219/SiCp-Gr hybrid metal matrix composites
NASA Astrophysics Data System (ADS)
Basavarajappa, S.; Chandramohan, G.; Mukund, K.; Ashwin, M.; Prabu, M.
2006-12-01
The dry sliding wear behavior of Al 2219 alloy and Al 2219/SiCp/Gr hybrid composites are investigated under similar conditions. The composites are fabricated using the liquid metallurgy technique. The dry sliding wear test is carried out for sliding speeds up to 6 m/s and for normal loads up to 60 N using a pin on disc apparatus. It is found that the addition of SiCp and graphite reinforcements increases the wear resistance of the composites. The wear rate decreases with the increase in SiCp reinforcement content. As speed increases, the wear rate decreases initially and then increases. The wear rate increases with the increase in load. Scanning electron microscopy micrographs of the worn surface are used to predict the nature of the wear mechanism. Abrasion is the principle wear mechanism for the composites at low sliding speeds and loads. At higher loads, the wear mechanism changes to delamination.
Comparison of dry sliding wear and friction behavior of Al6061/SiC PMMC with Al6061 alloy
NASA Astrophysics Data System (ADS)
Murthy, A. G. Shankara; Mehta, N. K.; Kumar, Pradeep
2018-04-01
Dry sliding wear and friction behavior tests were conducted on Al6061 alloy and Al6061/SiC particle reinforced metal matrix composites (PMMCs) reinforced with fine particles of 5, 10 and 15 µm size having 5,7.5 and 10% weight content fabricated by stir-casting route. Cylindrical sample pins produced as per ASTM standard were tested for various parameters like SiC size, weight content, load and sliding distance affecting the wear rate or resistance and friction. Results indicated that Al6061/SiCp composites exhibited good wear resistance compared to Al6061 alloy for the tested parameters.
Effect of strain hardening on friction behavior of iron lubricated with benzyl structures
NASA Technical Reports Server (NTRS)
Buckley, D. H.; Brainard, W. A.
1974-01-01
Sliding friction experiments were conducted with iron, copper, and aluminum in contact with iron in various states of strain. The surfaces were examined in dry sliding and with various benzyl compounds applied as lubricants. Friction experiments were conducted with a hemispherical rider contacting a flat disk at loads of from 50 to 600 grams with a sliding speed of 0.15 cm/min. Results indicate that straining increases friction for dry sliding and for surfaces lubricated with certain benzyl structures such as dibenzyl disulfide. With other benzyl compounds (e.g., benzyl formate), friction coefficients are lower for strained than for annealed iron.
Improved Wear Resistance of Low Carbon Steel with Plasma Melt Injection of WC Particles
NASA Astrophysics Data System (ADS)
Liu, Aiguo; Guo, Mianhuan; Hu, Hailong
2010-08-01
Surface of a low carbon steel Q235 substrate was melted by a plasma torch, and tungsten carbide (WC) particles were injected into the melt pool. WC reinforced surface metal matrix composite (MMC) was synthesized. Dry sliding wear behavior of the surface MMC was studied and compared with the substrate. The results show that dry sliding wear resistance of low carbon steel can be greatly improved by plasma melt injection of WC particles. Hardness of the surface MMC is much higher than that of the substrate. The high hardness lowers the adhesion and abrasion of the surface MMC, and also the friction coefficient of it. The oxides formed in the sliding process also help to lower the friction coefficient. In this way, the dry sliding wear resistance of the surface MMC is greatly improved.
Dry Sliding Tribological Studies of AA6061-B4C-Gr Hybrid Composites
NASA Astrophysics Data System (ADS)
Monikandan, V. V.; Joseph, M. A.; Rajendrakumar, P. K.
2016-10-01
The dry sliding behavior of stir-cast AA6061-10 wt.% B4C composites containing 2.5, 5 and 7.5 wt.% graphite particles was studied as a function of applied load, sliding speed and sliding distance on a pin-on-disk tribotester. The wear rate and friction coefficient increased with increase in applied load and sliding distance. The increase in graphite addition reduced the increase in wear rate and friction coefficient in the sliding speed range 2-2.5 m/s. Scanning electron microscopy of the worn pin revealed a graphite tribolayer, and transmission electron microscopy revealed overlapping deformation bands under 30 N applied load. Upon increasing the applied load to 40 N, welded region with fine crystalline structure was formed due to dynamic recrystallization of AA6061 alloy matrix.
Friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes
NASA Astrophysics Data System (ADS)
Deng, Jianxin; Yan, Pei; Wu, Ze
2012-11-01
MoS2 metal composite coatings have been successful used in dry turning, but its suitability for dry drilling has not been yet established. Therefore, it is necessary to study the friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes. In the present study, MoS2/Zr composite coatings are deposited on the surface of W6Mo5Cr4V2 high speed steel(HSS). Microstructural and fundamental properties of these coatings are examined. Ball-on-disc sliding wear tests on the coated discs are carried out, and the drilling performance of the coated drills is tested. Test results show that the MoS2/Zr composite coatings exhibit decreases friction coefficient to that of the uncoated HSS in sliding wear tests. Energy dispersive X-ray(EDX) analysis on the wear surface indicates that there is a transfer layer formed on the counterpart ball during sliding wear processes, which contributes to the decreasing of the friction coefficient between the sliding couple. Drilling tests indicate that the MoS2/Zr coated drills show better cutting performance compared to the uncoated HSS drills, coating delamination and abrasive are found to be the main flank and rake wear mode of the coated drills. The proposed research founds the base of the application of MoS2 metal composite coatings on dry drilling.
Dry sliding behavior of aluminum alloy 8011 with 12% fly ash composites
NASA Astrophysics Data System (ADS)
Magibalan, S.; Senthilkumar, P.; Palanivelu, R.; Senthilkumar, C.; Shivasankaran, N.; Prabu, M.
2018-05-01
This research focused on the fabrication of aluminum alloy 8011 with 12% fly ash (FA) composite (AA8011%–12% FA) using the stir casting method. A three-level central composite design experiment was developed using response surface methodology with various parameters such as load, time, and sliding velocity varied in the range of 5 to 15 N, 5 to 15 min, and 1.5 to 4.5 m.s‑1, respectively. Dry sliding wear tests were performed as per the experimental design using a pin on disc at room temperature. The obtained regression result indicated that the developed model performed well in relating the wear process parameters and predicted the wear behavior of the composite. The surface plot showed that the wear rate increases with increase in load, time, and sliding velocity. Hardness was evaluated by Vickers hardness testing machine. Moreover, the surface morphology of the worn-out composite was examined using a scanning electron microscope.
NASA Astrophysics Data System (ADS)
Mushtaq, Shuhaib; Wani, M. F.
2018-02-01
Solid lubricants are particularly used in the advanced mechanical motion systems with extreme conditions such as (high temperature, vacuum, radiation, extreme contact pressure, etc). The main focus of this paper is to study the dry sliding friction and wear behavior of Fe-Cu-Sn alloy with varying wt% of graphite at high temperature up to 423 K. The influence of temperature, sliding distance and load on friction and wear behavior of Fe-Cu-Sn alloy against EN8 steel was studied using ball (EN8) on disc (Fe-Cu-Sn alloy). Lower wear and lower friction of Fe-Cu-Sn alloy were observed at high temperature, as compared to room temperature. Surface morphological and surface analytical studies of fresh and worn surfaces were carried out using optical microscopy, 3D profilometer, scanning electron microscope, energy dispersive x-ray spectroscopy, XRD, and Raman spectroscopy to understand the friction and wear behavior.
Tribological dry sliding behavior of chopped carbon fiber reinforced polyetheretherketone
NASA Astrophysics Data System (ADS)
Chumaevskii, A. V.; Ivanov, A. N.; Filippov, A. V.; Rubtsov, V. E.; Kolubaev, E. A.
2017-12-01
Tribological tests on 3D printed pure polyetheretherketone and carbon fiber reinforced polyetheretherketone samples were carried out. The negative effect of carbon fiber sticking out of the matrix on wear and sliding process stability was revealed. These fibers may be too long and oriented to the worn surface in a manner that prevents their removal by wear so that the worn surface becomes irregular and the sliding process instable.
Graphene as a protective coating and superior lubricant for electrical contacts
NASA Astrophysics Data System (ADS)
Berman, Diana; Erdemir, Ali; Sumant, Anirudha V.
2014-12-01
Potential for graphene to be used as a lubricant for sliding electrical contacts has been evaluated. Graphene, being deposited as a sporadic flakes on the gold substrate sliding against titanium nitride ball shows not only significant improvement in tribological behavior by reducing both friction (by factor of 2-3) and wear (by 2 orders) but also, even more importantly, demonstrates stable and low electrical resistance at the sliding contacts undergoing thousands of sliding passes regardless of the test environment (i.e., both in humid and dry conditions).
Graphene as a lubricant for electrical contacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berman, Diana; Erdemir, Ali; Sumant, Anirudha V.
2014-12-08
Potential for graphene to be used as a lubricant for sliding electrical contacts has been evaluated. Graphene, being deposited as a sporadic flakes on the gold substrate sliding against titanium nitride ball shows not only significant improvement in tribological behavior by reducing both friction (by factor of 2-3) and wear (by 2 orders) but also, even more importantly, demonstrates stable and low electrical resistance at the sliding contacts undergoing thousands of sliding passes regardless of the test environment (i.e., both in humid and dry conditions). (C) 2014 AIP Publishing LLC.
Friction behavior of glass and metals in contact with glass in various environments
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1973-01-01
Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.
Effect of SiC particle impact nano-texturing on tribological performance of 304L stainless steel
NASA Astrophysics Data System (ADS)
Lorenzo-Martin, C.; Ajayi, O. O.
2014-10-01
Topographical features on sliding contact surfaces are known to have a significant impact on friction and wear. Indeed, various forms of surface texturing are being used to improve and/or control the tribological performance of sliding surfaces. In this paper, the effect of random surface texturing produced by a mechanical impact process is studied for friction and wear behavior of 304L stainless steel (SS) under dry and marginal oil lubrication. The surface processing was applied to 304L SS flat specimens and tested under reciprocating ball-on-flat sliding contact, with a 440C stainless steel ball. Under dry contact, the impact textured surface exhibited two order of magnitude lower wear than the isotropically ground surface of the same material. After 1500 s of sliding and wearing through of the processed surface layer following occurring of scuffing, the impact textured surface underwent a transition in wear and friction behavior. Under marginal oil lubrication, however, no such transition occurred, and the wear for the impact textured surface was consistently two orders of magnitude lower than that for the ground material. Mechanisms for the tribological performance enhancement are proposed.
NASA Astrophysics Data System (ADS)
Bhaskar Kurapati, Vijaya; Kommineni, Ravindra
2017-09-01
In the present work AA 2024 alloy reinforced with mixtures of SiC and Fly Ash (FA) particles of 70 µm (5, 10 and 15 wt. %) are fabricated using the stir casting method. Both reinforcements are added in equal weight proportions. The wear test specimens are prepared from both the alloy and composite castings in the dimensions of Ф 4 mm and 30 mm lengths by the wire cut EDM process. The dry sliding wear properties of the prepared composites at room temperature are estimated by pin-on-disc wear testing equipment. The wear characteristics of the composites are studied by conducting the dry sliding wear test over loads of 0.5 Kgf, 1.0 Kgf, 1.5 Kgf, a track diameter of 60 mm and sliding times of 15 min, 30 min, 45min. The experimental results shows that the wear decreases with an increase in the weight percentage of FA and SiC particles in the matrix. Additionally wear increases with an increase in load and sliding time. Further, it is found that the wear resistance of the AA2024-Hybrid composites is higher than that of the AA2024 matrix.
NASA Astrophysics Data System (ADS)
Awasthi, Reena; Limaye, P. K.; Kumar, Santosh; Kushwaha, Ram P.; Viswanadham, C. S.; Srivastava, Dinesh; Soni, N. L.; Patel, R. J.; Dey, G. K.
2015-03-01
In this study, dry sliding wear characteristics of the Ni-based hardfacing alloy (Ni-Mo-Cr-Si) deposited on stainless steel SS316L substrate by laser cladding have been presented. Dry sliding wear behavior of the laser clad layer was evaluated against two different counter bodies, AISI 52100 chromium steel (~850 VHN) and tungsten carbide ball (~2200 VHN) to study both adhesive and abrasive wear characteristics, in comparison with the substrate SS316L using ball on plate reciprocating wear tester. The wear resistance was evaluated as a function of load and sliding speed for a constant sliding amplitude and sliding distance. The wear mechanisms were studied on the basis of wear surface morphology and microchemical analysis of the wear track using SEM-EDS. Laser clad layer of Ni-Mo-Cr-Si on SS316L exhibited much higher hardness (~700 VHN) than that of substrate SS316L (~200 VHN). The laser clad layer exhibited higher wear resistance as compared to SS316L substrate while sliding against both the counterparts. However, the improvement in the wear resistance of the clad layer as compared to the substrate was much higher while sliding against AISI 52100 chromium steel than that while sliding against WC, at the same contact stress intensity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olofinjana, Bolutife; Ajayi, Oyelayo O.; Lorenzo-Martin, Cinta
In this study, friction and wear behavior of 304L stainless steel sliding against different ball counterface under dry contact was investigated. Tests were conducted using a ball-on-flat contact configuration in reciprocating sliding with 440C stainless steel, Al alloy (2017) and bronze ball counterfaces under different loads. Detailed surface analysis was also done using 3-D profilometry technique and optical microscopy in order to determine wear mechanism and dimension. All the pairs exhibited initial rapid increase in coefficient of friction after which a variety of friction behavior, depending on the ball counterface, was observed. The flat and the ball counterface in 304Lmore » stainless steel-440C stainless steel pair showed wear that was proportional to applied load. In both 304L stainless steel-Al alloy (2017) and 304L stainless steel-bronze pairs, ball samples showed severe wear that was proportional to the applied load while material transfer from the different balls occurred in the flat. The study concluded that friction and wear were not material properties but a kind of responses that characterize a pair of surfaces in contact undergoing relative motion.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erdemir, A.; Kovalchenko, A.; McNallan, M. J.
2004-01-01
In this study, we investigated the effects of a high-temperature hydrogenation treatment on the sliding friction and wear behavior of nanostructured carbide-derived carbon (CDC) films in dry nitrogen and humid air environments. These films are produced on the surfaces of silicon carbide substrates by reacting the carbide phase with chlorine or chlorine-hydrogen gas mixtures at 1000 to 1100 C in a sealed tube furnace. The typical friction coefficients of CDC films in open air are in the range of 0.2 to 0.25, but in dry nitrogen, the friction coefficients are 0.15. In an effort to achieve lower friction on CDCmore » films, we developed and used a special hydrogenation process that was proven to be very effective in lowering friction of CDC films produced on SiC substrates. Specifically, the films that were post-hydrogen-treated exhibited friction coefficients as low as 0.03 in dry nitrogen, while the friction coefficients in humid air were 0.2. The wear of Si{sub 3}N{sub 4} counterface balls was hard to measure after the tests, while shallow wear tracks had formed on CDC films on SiC disks. Detailed mechanical and structural characterizations of the CDC films and sliding contact surfaces were done using a series of analytical techniques and these findings were correlated with the friction and wear behaviors of as-produced and hydrogen-treated CDC films.« less
Liang, Guoxing; Schmauder, Siegfried; Lyu, Ming; Schneider, Yanling; Zhang, Cheng; Han, Yang
2018-01-01
Friction and wear tests were performed on AISI 1045 steel specimens with different initial roughness parameters, machined by a creep-feed dry grinding process, to study the friction and wear behavior on a pin-on-disc tester in dry sliding conditions. Average surface roughness (Ra), root mean square (Rq), skewness (Rsk) and kurtosis (Rku) were involved in order to analyse the influence of the friction and wear behavior. The observations reveal that a surface with initial roughness parameters of higher Ra, Rq and Rku will lead to a longer initial-steady transition period in the sliding tests. The plastic deformation mainly concentrates in the depth of 20–50 μm under the worn surface and the critical plastic deformation is generated on the rough surface. For surfaces with large Ra, Rq, low Rsk and high Rku values, it is easy to lose the C element in, the reciprocating extrusion. PMID:29401703
NASA Astrophysics Data System (ADS)
Zhao, Li; Chen, Wei; Dai, Jianwei; Wang, Zhangzhong; Zhang, Xiaobo
2017-11-01
Mg-6Gd-2Zn-0.4Zr (wt.%, GZ62K) alloy was processed by solution treatment under different temperatures. The microstructure, hardness, corrosion and wear behaviors in simulated body fluid (SBF) have been studied. The results indicate that the (Mg, Zn)3Gd phase decreases, the precipitated phases gradually increase, and the long-period stacking ordered structure disappears with the increase of solution temperature. The alloy has better corrosion resistance after solution treatment, and that solution treated at 490 °C for 12 h shows the best corrosion resistance. The friction coefficient of the alloy under dry sliding condition decreases slightly, but the mass loss increases with increasing the solution temperature. The alloy solution treated at 460 °C for 12 h exhibits the lowest friction coefficient and mass loss in SBF, and it also has the best wear resistance under dry sliding condition.
2008-09-01
In situ analysis of third body contributions to sliding friction of a pb-mo-s coating in dry and humid air. Tribol. Lett. 28, 263–274 (2007). doi...activated behavior in macroscopic tribology is reserved for systems with stable interfaces and ultra-low wear, and athermal behavior is characteristic to...efforts to measure and under- stand tribological behavior at cryogenic temperatures; to date, results of these efforts show either no trend or con- flicting
Temperature-Dependent Friction and Wear Behavior of PTFE and MoS 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Babuska, T. F.; Pitenis, A. A.; Jones, M. R.
2016-06-16
We present an investigation of the temperature-dependent friction behavior of PTFE, MoS 2, and PTFE-on- MoS 2. Friction behavior was measured while continuously varying contact temperature in the range -150 to 175°C while sliding in dry nitrogen, as well as for self-mated PTFE immersed in liquid nitrogen. These results contrast with previous reports of monotonic inverse temperature dependent friction behavior, as well as reported high-friction transitions and plateaus at temperatures below about -20°C that were not observed, providing new insights about the molecular mechanisms of macro-scale friction. The temperature-dependent friction behavior characteristic of self-mated PTFE was found also on themore » PTFE-on-MoS 2 sliding contact, suggesting that PTFE friction was defined by sub-surface deformation mechanisms and internal friction even when sliding against a lamellar lubricant with extremely low friction coefficient (μ ~ 0.02). The various relaxation temperatures of PTFE were found in the temperature-dependent friction behavior, showing excellent agreement with reported values acquired using torsional techniques measuring internal friction. Additionally, hysteresis in friction behavior suggests an increase in near-surface crystallinity at upon exceeding the high temperature relaxation, T α~ 116°C.« less
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1974-01-01
The lubricating properties of some benzyl and benzene structures were determined by using 304 stainless steel surfaces strained to various hardness. Friction coefficients and wear track widths were measured with a Bowden-Leben type friction apparatus by using a pin-on-disk specimen configuration. Results obtained indicate that benzyl monosulfide, dibenzyl disulfide, and benzyl alcohol resulted in the lowest friction coefficients for 304 stainless steel, while benzyl ether provided the least surface protection and gave the highest friction. Strainhardening of the 304 stainless steel prior to sliding resulted in reduced friction in dry sliding. With benzyl monosulfide, dibenzyl disulfide, and benzyl alcohol changes in 304 stainless steel hardness had no effect upon friction behavior.
Properties data for opening the Galileo's partially unfurled main antenna
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Pepper, Stephen V.
1992-01-01
An investigation was conducted into the friction and wear behavior of both unlubricated and dry-film-lubricated (Tiolube 460) titanium alloy (Ti-6Al-4V) in contact with an uncoated high-nickel-content superalloy (Inconel 718) both in vacuum and in air. The acquisition of friction and wear data for this sliding couple was motivated by the need for input data for the 'antenna stuck ribs model' effort to free Galileo's High Gain Antenna. The results of the investigation indicate that galling occurred in the unlubricated system in vacuum and that the coefficient of friction increased to 1.2. The abnormally high friction (1.45) was observed when relatively large wear debris clogged at the sliding interface. The coefficient of friction for the dry-film-lubricated system in vacuum is 0.04, while the value in air is 0.13. The endurance life of the dry-film lubricant is about three orders of magnitude greater in vacuum than in air. The worn surfaces of the dry-film-lubricated Ti-6Al-4V pin and Inconel 718 disk first run in humid air and then rerun in vacuum was completely different from that of the pin and disk run only in vacuum. When galling occurred in the humid-air and vacuum contact, coefficient of friction rose to 0.32 when sliding in humid air and to 1.4 when sliding in vacuum. The galling was accompanied by severe surface damage and extensive transfer of the Ti-6Al-4V to the Inconel 718, or vice versa. When spalling occurred in the dry-film-lubricated Ti-6Al-4V pin run only in vacuum, the coefficient of friction rose to 0.36 or greater. The wear damage caused by spalling can self-heal when rerun in vacuum - the coefficient of friction decreased to 0.05. The friction and wear data obtained can be used for the 'antenna stuck ribs model' effort to free Galileo's high gain antenna.
Ren, Fuzeng; Zhu, Weiwei; Chu, Kangjie
2016-07-01
Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fine grained (UFG) structure of ε-phase with average grain size of 600nm in length and 150nm in thickness. The hardness and modulus were determined to be 8.87±0.56GPa and 198.27±7.02GPa, respectively. The coefficient of friction upon dry sliding against alumina is pretty close to that of the forged Co-29Cr-6Mo alloy. The initial ε-phase and UFG microstructure contribute to reduce the depth of severe plastic deformation region during wear and enable the alloy with excellent wear resistance. The corrosion potential of such UFG Co-Cr-Mo alloy has more positive corrosion potential and much lower corrosion current density than those of ASTM alloy. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tribological behaviors of UHMWPE composites with different counter surface morphologies
NASA Astrophysics Data System (ADS)
Wang, Yanzhen; Yin, Zhongwei; Li, Hulin; Gao, Gengyuan
2017-12-01
The influence of counter surface morphologies on hybrid glass fiber (GF) and carbon fiber (CF) filled ultrahigh molecular weight polyethylene (UHMWPE) were studied under various contact pressure and sliding speed against GCr15 steel in dry condition. The goals were to investigate the tribological behavior of GF/CF/UHMWPE composite as a kind of water lubricated journal bearing material. The friction and wear behavior of composites were examined using a pin-on-disc tribometer. The morphologies of the worn surface were examined by scanning electron microscopy (SEM) and laser 3D micro-imaging and profile measurement. Generally, the wear rate and friction coefficient of composites increase as the increment of counter surface roughness. The friction coefficient increases firstly and then decrease with an increase in sliding speed and contact pressure for counterface with Ra=0.2 and 3.5 μm, while the friction coefficient decreased for counterface with Ra=0.6 μm.
NASA Astrophysics Data System (ADS)
Pang, Zuobo; Zhou, Hong; Xie, Guofeng; Cong, Dalong; Meng, Chao; Ren, Luquan
2015-07-01
In order to get close to the wear form of guide rails, the homemade linear reciprocating wear testing machine was used for the wear test. In order to improve the wear-resistance of gray cast iron guide rail, bionic coupling units of different forms were manufactured by a laser. Wear behavior of gray-cast-iron with bionic-coupling units has been studied under dry sliding condition at room temperature using the wear testing machine. The wear resistance was evaluated by means of weight loss measurement and wear morphology. The results indicated that bionic coupling unit could improve the wear resistance of gray cast iron. The wear resistance of gray cast iron with reticulation bionic coupling unit is the best. When the load and speed changed, reticulation bionic coupling unit still has excellent performance in improving the wear resistance of gray cast iron.
Drying induced upright sliding and reorganization of carbon nanotube arrays
NASA Astrophysics Data System (ADS)
Li, Qingwen; DePaula, Raymond; Zhang, Xiefei; Zheng, Lianxi; Arendt, Paul N.; Mueller, Fred M.; Zhu, Y. T.; Tu, Yi
2006-09-01
Driven by capillary force, wet carbon nanotube (CNT) arrays have been found to reorganize into cellular structures upon drying. During the reorganization process, individual CNTs are firmly attached to the substrate and have to lie down on the substrate at cell bottoms, forming closed cells. Here we demonstrate that by modifying catalyst structures, the adhesion of CNTs to the substrate can be weakened. Upon drying such CNT arrays, CNTs may slide away from their original sites on the surface and self-assemble into cellular patterns with bottoms open. It is also found that the sliding distance of CNTs increases with array height, and drying millimetre tall arrays leads to the sliding of CNTs over a few hundred micrometres and the eventual self-assembly into discrete islands. By introducing regular vacancies in CNT arrays, CNTs may be manipulated into different patterns.
NASA Astrophysics Data System (ADS)
Lee, Jung-Moo; Kang, Suk-Bong; Yoon, Sang-Chul
1999-07-01
The wear behavior of hypereutectic aluminium-silicon alloy A390 was investigated using a pin-on-disc wear machine under dry sliding conditions. The wear tests were performed within a load range of 10 to 300N at a constant sliding velocity of 0.5 m/sec. The microstructural and compositional changes that took place during wear were characterized by scanning electron microscopy (SEM) equipped with an energy dispersive X-ray analysis (EDXA) system. Based on the metallographic observations the role of the primary silicon particles was suggested. In a low pressure region, primary silicon particles supported the applied load and wear occurred mainly in the matrix. Thus the wear loss did not show much variation with the applied load. In the mid-load range, primary silicon particles did not yet fracture and thus supported the applied load in part. Transition from oxidative to metallic wear occurs mainly in the matrix and the increase of wear loss becomes sharper than that in a low pressure region. In the high pressure region, the fractures of primary silicon Particles occurred and wear loss increased sharply.
NASA Astrophysics Data System (ADS)
Ram, Subhash Chandra; Chattopadhyay, K.; Chakrabarty, I.
2018-04-01
Functionally graded A356 alloy (Al–7.2Si–0.3Mg) –Mg2Si in situ composites have been synthesized via centrifugal casting route. Mg2Si particles tend to migrate towards the core of the tubular product by centrifugal force. The in situ formed Mg2Si particles in composites are characterized by x-ray diffraction (XRD) analysis, Energy dispersive spectrometry (EDS), Optical, Scanning Electron and Transmission Electron Microscopy. Apart from primary blocky Mg2Si particles the matrix contains other phases viz. Al-Si eutectic, pseudo-binary Al-Mg2Si eutectic and Al-Fe-Si intermetallics. Density is found to decrease and %porosity is increased with increase in volume fraction of Mg2Si. Maximum hardness was observed at the inner core region due to maximum segregation of Mg2Si particles and gradually decreases towards the outer periphery region. The dry sliding wear was evaluated with varying parameters such as normal loads (N) and sliding distances (m). A substantial increase in wear resistance at the inner core region is observed. From the worn surface characterization, the wear mechanisms have been explained.
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Iwaki, Masanori; Gotoh, Kenichi; Obara, Shingo; Imagawa, Kichiro
2000-01-01
To evaluate commercially developed dry solid film lubricants for aerospace bearing applications, an investigation was conducted to examine the friction and wear behavior of magnetron-sputtered diamondlike carbon (MS DLC) and plasma-assisted, chemical-vapor-deposited diamondlike carbon (PACVD DLC) films in sliding contact with 6-mm-diameter American Iron and Steel Institute (AISI) 440C stainless steel balls. Unidirectional sliding friction experiments were conducted with a load of 5.9 N (600 g), a mean Hertzian contact pressure of 0.79 GPa (maximum Hertzian contact pressure of L-2 GPa), and a sliding velocity of 0.2 m/s. The experiments were conducted at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7x10(exp -7) Pa), humid air (relative humidity, approx.20 percent), and dry nitrogen (relative humidity, <1 percent). The resultant films were characterized by scanning electron microscopy, energy-dispersive x-ray spectroscopy, and surface profilometry. Marked differences in the friction and wear of the DLC films investigated herein resulted from the environmental conditions. The main criteria for judging the performance of the DLC films were coefficient of friction and wear rate, which had to be less than 0.3 and on the order of 10(exp -6) cu mm/N-m or less, respectively. MS DLC films and PACVD DLC films met the criteria in humid air and dry nitrogen but failed in ultrahigh vacuum, where the coefficients of friction were greater than the criterion, 0.3. In sliding contact with 440C stainless steel balls in all three environments the PACVD DLC films exhibited better tribological performance (i.e., lower friction and wear) than the MS DLC films. All sliding involved adhesive transfer of wear materials: transfer of DLC wear debris to the counterpart 440C stainless steel and transfer of 440C stainless steel wear debris to the counterpart DLC film.
Tribological performance of quaternary CrSiCN coatings under dry and lubricated conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lorenzo-Martin, C.; Ajayi, O.; Erdemir, A.
This paper presents an experimental study of friction and wear performance of quaternary CrSiCN coatings deposited on a hardened H-13 steel substrate by a plasma enhanced magnetron sputtering (PEMS) technique. Friction and wear tests were conducted with a reciprocating line contact between a hardened 4370 steel roller and coated and uncoated flat specimens under dry and lubricated conditions. The effects of coating thickness (1, 3.5 and 7.5 μm) on the mechanical properties, friction and wear performance were also assessed. In dry sliding, the friction of coated surfaces was about the same as for uncoated surfaces, except for the 1-μm coating,more » which had higher friction. Friction for coated surfaces under lubricated contact was in general higher than for uncoated surfaces. There was no measurable wear on any of the coated surfaces, under either dry or lubricated conditions. However, wear was higher on the steel roller counterface sliding against the coated surfaces, with the amount of wear proportional to the mating coating thickness. The effectiveness of formulated lubricant additives was also modified by the coating, resulting in major effects on friction and wear behavior. Finally, this reduction in lubricant additive efficacy is due to the fact that the additives were designed and optimized for ferrous surfaces.« less
Tribological performance of quaternary CrSiCN coatings under dry and lubricated conditions
Lorenzo-Martin, C.; Ajayi, O.; Erdemir, A.; ...
2017-06-15
This paper presents an experimental study of friction and wear performance of quaternary CrSiCN coatings deposited on a hardened H-13 steel substrate by a plasma enhanced magnetron sputtering (PEMS) technique. Friction and wear tests were conducted with a reciprocating line contact between a hardened 4370 steel roller and coated and uncoated flat specimens under dry and lubricated conditions. The effects of coating thickness (1, 3.5 and 7.5 μm) on the mechanical properties, friction and wear performance were also assessed. In dry sliding, the friction of coated surfaces was about the same as for uncoated surfaces, except for the 1-μm coating,more » which had higher friction. Friction for coated surfaces under lubricated contact was in general higher than for uncoated surfaces. There was no measurable wear on any of the coated surfaces, under either dry or lubricated conditions. However, wear was higher on the steel roller counterface sliding against the coated surfaces, with the amount of wear proportional to the mating coating thickness. The effectiveness of formulated lubricant additives was also modified by the coating, resulting in major effects on friction and wear behavior. Finally, this reduction in lubricant additive efficacy is due to the fact that the additives were designed and optimized for ferrous surfaces.« less
An investigation on dry sliding wear behaviour of AA6061-AlNp composite
NASA Astrophysics Data System (ADS)
Mahesh Naidu, K.; Mohan Reddy, Chandra
2018-03-01
This paper studies the effect of load, sliding distance, reinforcement percentage and temperature on dry sliding wear behaviour of Al-AlNp composites by using pin on disc machine. The wear test was conducted at different loads (1,2,3 & 4 Kg), temperatures (30°C, 100°C, 170°C & 240°C) and sliding distances (500m,1000m,1500m and 2000m). Increase in wear rate has been observed by increasing the load and sliding distance, at the same time it has been decreased by increasing the reinforcement percentage and temperature. At the higher loads, temperatures and sliding distances adhesive wear, abrasive wear and oxidation wear are observed to be dominant modes of wear mechanisms in the composite.
Friction and wear behavior of nitrogen-doped ZnO thin films deposited via MOCVD under dry contact
Mbamara, U. S.; Olofinjana, B.; Ajayi, O. O.; ...
2016-02-01
Most researches on doped ZnO thin films are tilted toward their applications in optoelectronics and semiconductor devices. Research on their tribological properties is still unfolding. In this work, nitrogen-doped ZnO thin films were deposited on 304 L stainless steel substrate from a combination of zinc acetate and ammonium acetate precursor by MOCVD technique. Compositional and structural studies of the films were done using Rutherford Backscattering Spectroscopy (RBS) and X-ray Diffraction (XRD). The frictional behavior of the thin film coatings was evaluated using a ball-on-flat configuration in reciprocating sliding under dry contact condition. After friction test, the flat and ball counter-facemore » surfaces were examined to assess the wear dimension and failure mechanism. In conclusion, both friction behavior and wear (in the ball counter-face) were observed to be dependent on the crystallinity and thickness of the thin film coatings.« less
NASA Astrophysics Data System (ADS)
Jebran Khan, Mohammad; Wani, M. F.; Gupta, Rajat
2018-05-01
The present study aims at investigating the tribological behavior of glass fiber filled PTFE on sliding against AISI 420 stainless steel in ambient air, distilled water and natural sea water. The friction and wear tests were carried out using a pin-on-disc configuration at room temperature on 25 wt% glass fiber filled PTFE at a normal load of 10 N. The glass fiber filled PTFE showed superior tribological performance in sea water compared to dry sliding and distilled water environment conditions. The lowest average coefficient of friction of 0.028 and lowest specific wear rate of 5.85 × 10‑6 mm3 Nm‑1 was observed under sea water environment. The worn surfaces were examined using Optical microscopy, SEM, EDS and Raman spectroscopy to reveal the wear mechanisms. It was revealed that the superior tribological performance of glass fiber filled PTFE in sea water is due to the formation of a lubricating film on the surface of glass fiber filled PTFE in sea water. The profilometric traces of the counterface after tribological tests were taken using an optical 3D surface profilometer to investigate the effect of indirect corrosive wear on the friction and wear of glass fiber filled PTFE under sea water environment.
Friction and Wear Properties of Selected Solid Lubricating Films. Part 2; Ion-Plated Lead Films
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Iwaki, Masanori; Gotoh, Kenichi; Obara, Shingo; Imagawa, Kichiro
2000-01-01
To evaluate commercially developed dry solid film lubricants for aerospace bearing applications, an investigation was conducted to examine the friction and wear behavior of ion-plated lead films in sliding contact with 6-mm-diameter American Iron and Steel Institute (AISI) 440C stainless steel balls. Unidirectional sliding friction experiments were conducted with a load of 5.9 N (600 g), a mean Hertzian contact pressure of 0.79 GPa (maximum Hertzian contact pressure of 1.2 GPa), and a sliding velocity of 0.2 m/s. The experiments were conducted at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7 x 10(exp -7 Pa), humid air (relative humidity, approx. 20 percent), and dry nitrogen (relative humidity, less then 1 percent). The resultant films were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and surface profilometry. Marked differences in the friction and wear of the ion-plated lead films investigated herein resulted from the environmental conditions. The main criteria for judging the performance of the ion-plated lead films were coefficient of friction and wear rate, which had to be less than 0.3 and on the order of 1(exp -6) cu mm/N.m or less, respectively. The ion-plated lead films met both criteria only in ultrahigh vacuum but failed in humid air and in dry nitrogen, where the coefficient of friction was higher than the criterion. Both the lead film wear rate and the ball wear rate met that criterion in all three environments. Adhesion and plastic deformation played important roles in the friction and wear of the ion-plated lead films in contact with 440C stainless steel balls in the three environments. All sliding involved adhesive transfer of materials: transfer of lead wear debris to the counterpart 440C stainless steel and transfer of 440C stainless steel wear debris to the counterpart lead.
A method for reducing the sloughing of thick blood films for malaria diagnosis.
Norgan, Andrew P; Arguello, Heather E; Sloan, Lynne M; Fernholz, Emily C; Pritt, Bobbi S
2013-07-08
The gold standard for malaria diagnosis is the examination of thick and thin blood films. Thick films contain 10 to 20 times more blood than thin films, correspondingly providing increased sensitivity for malaria screening. A potential complication of thick film preparations is sloughing of the blood droplet from the slide during staining or rinsing, resulting in the loss of sample. In this work, two methods for improving thick film slide adherence ('scratch' (SCM) and 'acetone dip' (ADM) methods) were compared to the 'standard method' (SM) of thick film preparation. Standardized blood droplets from 26 previously examined EDTA whole blood specimens (22 positive and four negative) were concurrently spread on glass slides using the SM, ADM, and SCM. For the SM and ADM prepared slides, the droplet was gently spread to an approximate 22 millimeters in diameter spot on the slide using the edge of a second glass slide. For the SCM, the droplet was spread by carefully grinding (or scratching) it into the slide with the point of a second glass slide. Slides were dried for one hour in a laminar flow hood. For the ADM, slides were dipped once in an acetone filled Coplin jar and allowed to air dry. All slides were then Giemsa-stained and examined in a blinded manner. Adherence was assessed by blinded reviewers. No significant or severe defects were observed for slides prepared with the SCM. In contrast, 8 slides prepared by the ADM and 3 prepared using the SM displayed significant or severe defects. Thick films prepared by the three methods were microscopically indistinguishable and concordant results (positive or negative) were obtained for the three methods. Estimated parasitaemia of the blood samples ranged from 25 to 429,169 parasites/μL of blood. The SCM is an inexpensive, rapid, and simple method that improves the adherence of thick blood films to standard glass slides without altering general slide preparation, microscopic appearance or interpretability. Using the SCM, thick films can be reliably examined less than two hours after sample receipt. This represents a significant diagnostic improvement over protocols requiring extended drying periods.
Strength and deformation mechanisms of rhyolitic glass at lower seismogenic zone conditions
NASA Astrophysics Data System (ADS)
Proctor, B.; Lockner, D. A.; Lowenstern, J. B.; Beeler, N. M.
2017-12-01
Although its relevance to coseismic earthquake source properties is still debated, frictional melting and the production of quenched glass called pseudotachylyte is a recurring process in some earthquake source regions. To investigate how glassy materials affect the post- and interseismic- strength and stability of faults, rhyolitic obsidian gouges were sheared under dry and wet conditions from 200 °C to 300 °C at effective normal stresses up to 200 MPa. Velocity-stepping and slide-hold slide tests were performed for up to three days. Dry glass gouges exhibited a brittle rheology at all conditions tested, exhibiting friction values and microstructures consistent with siliciclastic materials. Likewise, wet glass gouges at 200 °C exhibited a brittle rheology. In contrast, wet gouges at 300 °C transitioned from brittle sliding to linear-viscous (Newtonian) flow at strain rates < 3x10-4 s-1, indicating melt-like behavior well below the equilibrium melting temperature. The melt ranged from 2.1x1011 to 2.6x1012 Pa-s. The molten gouges transitioned back to glass when strain rates were increased, which, in some cases, promoted extreme strengthening. The molten gouges were fully welded with rod-shaped microlites rotated and boudinaged into the flow direction. There was very little evidence for nucleation of new phases within the glass or metasomatic alteration. Fourier transform infrared spectroscopy along with electron backscatter imaging demonstrate that hydration of the glass by diffusion of pore water was the dominant process reducing the viscosity and promoting melt flow. As much as 5 wt% water diffused into the nominally anhydrous glass. These results may provide insight into postseismic-slip behaviors and challenge some interpretations of fault kinematics which assume pseudotachylyte formation and flow is solely coseismic.
Relating Mechanical Behavior and Microstructural Observations in Calcite Fault Gouge
NASA Astrophysics Data System (ADS)
Carpenter, B. M.; Di Stefano, G.; Viti, C.; Collettini, C.
2013-12-01
Many important earthquakes, magnitude 5-7, nucleate and/or propagate through carbonate-dominated lithologies. Additionally, the presence of precipitated calcite in (cement) and near (vein fill) faults indicates that the mechanical behavior of carbonate-dominated material likely plays an important role in shallow- and mid-crustal faulting. We report on laboratory experiments designed to explore the mechanical behavior of calcite and relate that behavior to post experiment microstructural observations. We sheared powdered gouge of Carrara Marble, >98% CaCO3, at constant normal stresses between 1 and 50 MPa under saturated conditions at room temperature. We performed velocity-stepping tests, 0.1-1000 μm/s, to evaluate frictional stability, and slide-hold-slide tests, 1-10,000 seconds, to measure the amount of frictional healing. Small subsets of experiments were performed under different environmental conditions and shearing velocities to better elucidate physicochemical processes and their role in the mechanical behavior of calcite fault gouge. All experimental samples were collected for SEM analysis. We find that the frictional healing rate is 7X higher under saturated conditions than under nominally dry conditions. We also observe a divergence between the rates of creep relaxation (increasing) and frictional healing (decreasing) as shear velocity is increased from 1 to 3000 μm/s. Our highest healing rates are observed at our lowest normal stresses. We observe a frictional strength of μ = 0.64, consistent with previous data under similar conditions. Furthermore, although we observe velocity-weakening frictional behavior in both the saturated and dry cases, rate- and-state friction parameters are distinctly different for each case. Our combined observations of rapid healing and of velocity-weakening frictional behavior indicate that faults where calcite-dominated gouge is present are likely to be seismic and have the ability to regain their strength quickly. Furthermore, our mechanical results highlight the important role of fluids in the evolution of frictional strength and thus fault behavior.
TiN-Coating Effects on Stainless Steel Tribological Behavior Under Dry and Lubricated Conditions
NASA Astrophysics Data System (ADS)
Zhang, Liqiang; Yang, Huisheng; Pang, Xiaolu; Gao, Kewei; Tran, Hai T.; Volinsky, Alex A.
2014-04-01
The tribological properties of magnetron sputtered titanium nitride coating on 316L steel, sliding against Si3N4 ceramic ball under dry friction and synthetic perspiration lubrication, were investigated. The morphology of the worn surface and the elemental composition of the wear debris were examined by scanning electron microscopy and energy dispersive spectroscopy. TiN coatings and 316L stainless steel had better tribological properties under synthetic perspiration lubrication than under dry friction. Among the three tested materials (316L, 1.6 and 2.4 μm TiN coatings), 2.4 μm TiN coating exhibits the best wear resistance. The difference in wear damage of the three materials is essentially due to the wear mechanisms. For the TiN coating, the damage is attributed to abrasive wear under synthetic perspiration lubrication and the complex interactive mechanisms, including abrasive and adhesive wear, along with plastic deformation, under dry friction.
Spectral analysis of the stick-slip phenomenon in "oral" tribological texture evaluation.
Sanahuja, Solange; Upadhyay, Rutuja; Briesen, Heiko; Chen, Jianshe
2017-08-01
"Oral" tribology has become a new paradigm in food texture studies to understand complex texture attributes, such as creaminess, oiliness, and astringency, which could not be successfully characterized by traditional texture analysis nor by rheology. Stick-slip effects resulting from intermittent sliding motion during kinetic friction of oral mucosa could constitute an additional determining factor of sensory perception where traditional friction coefficient values and their Stribeck regimes fail in predicting different lubricant (food bolus and saliva) behaviors. It was hypothesized that the observed jagged behavior of most sliding force curves are due to stick-slip effects and depend on test velocity, normal load, surface roughness as well as lubricant type. Therefore, different measurement set-ups were investigated: sliding velocities from 0.01 to 40 mm/s, loads of 0.5 and 2.5 N as well as a smooth and a textured silicone contact surface. Moreover, dry contact measurements were compared to model food systems, such as water, oil, and oil-in-water emulsions. Spectral analysis permitted to extract the distribution of stick-slip magnitudes for specific wave numbers, characterizing the occurrence of jagged force peaks per unit sliding distance, similar to frequencies per unit time. The spectral features were affected by all the above mentioned tested factors. Stick-slip created vibration frequencies in the range of those detected by oral mechanoreceptors (0.3-400 Hz). The study thus provides a new insight into the use of tribology in food psychophysics. Dynamic spectral analysis has been applied for the first time to the force-displacement curves in "oral" tribology. Analyzing the stick-slip phenomenon in the dynamic friction provides new information that is generally overlooked or confused with machine noise and which may help to understand friction-related sensory attributes. This approach allows us to differentiate samples that have similar friction coefficient, but are perceived differently in the mouth. The next step of our research will be to combine spectral attributes, such as the magnitudes of specific wave number bands and possibly their evolution during sliding, together with friction coefficient and viscosity values of foods with sensory results. The highest potential lies in predicting smoothness in opposition to roughness of a surface, such as a rough tongue when eating astringent or dry foods, or of particles when eating grainy foods. The effects of food ingredients at the nano to macroscales can then be used to optimize a specific lubrication behavior. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zou, Jiaojuan; Li, Maolin; Lin, Naiming; Zhang, Xiangyu; Qin, Lin; Tang, Bin
2014-12-01
In order to improve the tribological performance of AISI 316 stainless steel (316 SS) under grease lubrication, electrochemical processing was conducted on it to obtain a rough (surface texturing-like) surface by making use of the high sensitivity of austenitic stainless steel to pitting corrosion in Cl--rich environment. Numerous corrosion pits or micro-ditches acted as micro-reservoirs on the obtained surface. While the grease could offer consistent lubrication, and then improve the tribological performance of 316 SS. Tribological behaviors of raw 316 SS and the treated sample were measured using a reciprocating type tribometer sliding against GCr15 steel counterpart under dry and grease lubrication conditions. The results showed that the mass losses of the two samples were in the same order of magnitude, and the raw sample exhibited lower friction coefficient in dry sliding. When the tests were conducted under grease lubrication condition, the friction coefficients and mass losses of the treated sample were far lower than those of the raw 316 SS. The tribological performance of 316 SS under grease lubrication was drastically improved after electrochemical processing.
Effect of Microstructural Evolution and Hardening in Subsurface on Wear Behavior of Mg-3Al-1Zn Alloy
NASA Astrophysics Data System (ADS)
Liang, C.; Li, C.; An, J.; Yu, M.; Hu, Y. C.; Lin, W. H.; Liu, F.; Ding, Y. H.
2013-12-01
Dry sliding tests were performed on as-cast AZ31 alloy using a pin-on-disc configuration. Coefficient of friction and wear rate were measured within a load range of 5-360 N at a sliding velocity of 0.785 m/s. Worn surface morphologies were examined using scanning electron microscopy. Five wear mechanisms, namely abrasion, oxidation, delamination, thermal softening, and melting, have been observed. Surface hardness, subsurface plastic strain, worn surface temperature, and cross-sectional optical microscopy were used to characterize hardness change, plastic deformation, and the microstructure evolution in subsurface. The results illustrate the correlation between the wear behavior and evolution of microstructure and hardness in subsurface, and reveal that in the load range of 5-120 N, surface oxidation and hardening originating from large plastic deformation play an important role in maintaining the mild wear, and softening originating from dynamic recrystallization in subsurface and surface melting are responsible for the severe wear in the load range of 120-360 N.
Heat treated twin wire arc spray AISI 420 coatings under dry and wet abrasive wear
NASA Astrophysics Data System (ADS)
Rodriguez, E.; González, M. A.; Monjardín, H. R.; Jimenez, O.; Flores, M.; Ibarra, J.
2017-11-01
The influence of applying two different heat treatments such as: deep cryogenic and tempering on dry/wet abrasive wear resistance of twin wire arc spray martensitic AISI 420 coatings was evaluated by using a modified rubber wheel type test apparatus. A load dependency was observed on the abrasive wear rate behavior of both; dry and wet tests. Three body (rolling) and two body (sliding) wear mechanisms were identified in dry conditions, prevailing rolling at lower and higher loads. However, at higher loads, more presence of grooving and pits formation was observed. Coatings tempered at 205 °C/1 h displayed better wear resistance than cryogenic treated ones. A change in wear mechanism between dry and wet conditions was observed; two body wear mechanism predominated respect to three body. In both; dry and wet conditions the microstructure (several inter-splat oxides) as well as strain and residual stress promotes brittle material removal which was more evident in cryogenic and as-sprayed samples during dry test and at higher loads in wet conditions.
NASA Astrophysics Data System (ADS)
Tillmann, W.; Hagen, L.; Kokalj, D.
2017-10-01
In terms of arc-sprayed coatings, the lamellar coating microstructure is mainly affected by the atomization behavior of the molten electrode tips. When using compressed air, oxide formations occur during atomization, across the particle-laden spray plume and when the molten droplets splash onto the substrate. Within the scope of this study, the potential of a high-velocity arc-spraying process due to elevated atomization gas pressures and its effect on the spray and coating characteristics was analyzed using a cast tungsten carbide (CTC)-reinforced FeCMnSi cored wire. Since the atomization behavior corresponds with the electrode phenomena, the power spectrum and the droplet formation were observed during spraying. The tribo-mechanical properties of CTC-FeCMnSi coatings were examined in dry sliding experiments and indentation tests. In addition, adhesion tests and metallographic investigations were carried out to analyze the bonding strength, cohesive behavior, and lamellar microstructure. The occurrence of oxide phases was evaluated by x-ray diffraction and electron microscopy. Moreover, the oxygen content was determined by using glow discharge optical emission spectroscopy as well as energy-dispersive x-ray spectroscopy. With respect to elevated atomization gas pressures, a dense microstructure with improved adhesion to the substrate and reduced surface roughness was observed. Dry sliding experiments revealed an advanced wear behavior of specimens, when using above average increased atomization gas pressures. Analytic methods verified the existence of oxide phases, which were generated during spraying. A significant change of the extent and type of oxides, when applying an increased flow rate of the atomization gas, cannot be observed. Besides an enhanced coating quality, the use of increased atomization gas pressure exhibited good process stability.
NASA Astrophysics Data System (ADS)
Gou, Junfeng; Zhang, Jian; Zhang, Qiwen; Wang, You; Wang, Chaohui
2017-04-01
In this paper, the effect of nano-Si3N4 additives and plasma treatment on the wear behavior of Al2O3-8YSZ ceramic coatings was studied. Nano-Al2O3, nano-8YSZ (8 wt.% Y2O3-stabilized ZrO2) and nano-Si3N4 powders were used as raw materials to fabricate four types of sprayable feedstocks. Plasma treatment was used to improve the properties of the feedstocks. The surface morphologies of the ceramic coatings were observed. The mechanical properties of the ceramic coatings were measured. The dry sliding wear behavior of the Al2O3-8YSZ coatings with and without Si3N4 additives was studied. Nano-Si3N4 additives and plasma treatment can improve the morphologies of the coatings by prohibiting the initiation of micro-cracks and reducing the unmelted particles. The hardness and bonding strength of AZSP (Al2O3-18 wt.% 8YSZ-10 wt.% Si3N4-plasma treatment) coating increased by 79.2 and 44% compared to those of AZ (Al2O3-20 wt.% 8YSZ) coating. The porosity of AZSP coating decreased by 85.4% compared to that of AZ coating. The wear test results showed that the addition of nano-Si3N4 and plasma treatment could improve the wear resistance of Al2O3-8YSZ coatings.
Onset of frictional sliding of rubber–glass contact under dry and lubricated conditions
Tuononen, Ari J.
2016-01-01
Rubber friction is critical in many applications ranging from automotive tyres to cylinder seals. The process where a static rubber sample transitions to frictional sliding is particularly poorly understood. The experimental and simulation results in this paper show a completely different detachment process from the static situation to sliding motion under dry and lubricated conditions. The results underline the contribution of the rubber bulk properties to the static friction force. In fact, simple Amontons’ law is sufficient as a local friction law to produce the correct detachment pattern when the rubber material and loading conditions are modelled properly. Simulations show that micro-sliding due to vertical loading can release initial shear stresses and lead to a high static/dynamic friction coefficient ratio, as observed in the measurements. PMID:27291939
The effect of fluids on the frictional behavior of calcite gouge
NASA Astrophysics Data System (ADS)
Rempe, M.; Di Toro, G.; Mitchell, T. M.; Hirose, T.; Smith, S. A. F.; Renner, J.
2016-12-01
The presence of fluids in fault zones affects the faults' strength and the nucleation and propagation of earthquakes due to mechanical or physico-chemical weakening effects. To better understand the effect of pore fluids on the frictional behavior of gouge-bearing faults, a series of intermediate- to high-velocity experiments was conducted using the Phv rotary-shear apparatus (Kochi Core Center, Japan) equipped with a servo-controlled pore-fluid pressure system. Calcite gouge was sheared up to several meters displacement at room-humidity (dry) and water-saturated conditions. The pore-fluid factor, λ=pf/σn, ranged from 0.15 to 0.7 and the effective normal stress, σn,eff=σn-pf, from 1 to 12 MPa. Sheared samples were analyzed using scanning electron microscopy and Raman spectroscopy. The steady-state shear stress is lower for saturated than for dry gouges sliding at V=1 mm/s, possibly due to higher intergranular lubrication and/or accelerated subcritical crack growth, as evidenced also by the observed higher degree of compaction. At V=1 m/s, dry gouges show a pronounced strengthening phase preceding the onset of dynamic weakening; saturated gouges weaken abruptly. The higher λ, the lower the peak and steady-state shear stress, but -counterintuitively- the less localized deformation. Degree of weakening and localization might be influenced by insufficient drainage at high λ. In undrained experiments, the shear stress is slightly decreased likely due to thermal pressurization of the pore fluid, but the onset of dynamic weakening is not accelerated, indicating that dynamic weakening is due to more efficient mechanisms. For example, amorphous carbon may lubricate the slip surfaces of dry and saturated calcite gouges and cause dynamic weakening, yet Raman spectra only show the presence of disordered carbon on the principal slip surface. Furthermore, the presence of small recrystallized grains suggests that strain accommodation during steady-state slip might occur by non-frictional processes, such as grain-boundary sliding aided by diffusion creep.
Epoxy matrix composites filled with micro-sized LD sludge: wear characterization and analysis
NASA Astrophysics Data System (ADS)
Purohit, Abhilash; Satapathy, Alok
2016-02-01
Owing to the very high cost of conventional filler materials in polymer composites, exploring the possibility of using low cost minerals and industrial wastes for this purpose has become the need of the hour. In view of this, the present work includes the development and the wear performance evaluation of a new class of composites consisting of epoxy and microsized LD sludge. LD sludge or the Linz-Donawitz Sludge (LDS) are the fine solid particles recovered after wet cleaning of the gas emerging from LD convertors during steel making. Epoxy composites filled with different proportions (0, 5, 10, 15 and 20 wt %) of LDS are fabricated by conventional hand lay-up technique. Dry sliding wear trials are performed on the composite specimens under different test conditions as per ASTM G 99 following a design of experiment approach based on Taguchi's orthogonal arrays. The Taguchi approach leads to the recognition of most powerful variables that predominantly control the wear rate. This parametric analysis reveals that LDS content and sliding velocity affects the specific wear rate more significantly than normal load and sliding distance. Furthermore with increase in LDS content specific wear rate of the composite decreases for a constant sliding velocity. The sliding wear behavior of these composites under an extended range of test conditions is predicted by a model based on the artificial neural network (ANN).
NASA Astrophysics Data System (ADS)
Pal, Arpan; Poria, Suswagata; Sutradhar, Goutam; Sahoo, Prasanta
2018-03-01
In the present study, the effects of WC nano-particles content on the microstructure, hardness, wear, and friction behavior of aluminum matrix composites are investigated. Al-WC nano composites with varying wt% of WC (0, 1, 1.5, and 2) are fabricated using ultrasonic cavitation assisted stir-cast method. The microstructure of the nano-composite samples is analyzed using optical microscopy and scanning electron microscopy. Elemental composition is determined by energy dispersive x-ray analysis. Vicker’s microhardness test is performed in different locations on the composite sample surface with a load of 50 gf and 10s dwell time. Wear and friction of the composites under dry sliding is studied using a pin-on-disk tribotester for varying normal load (10–40 N) and sliding speed (0.1–0.4 m/s). Uniform distribution of nano-WC is observed over composite surface without noticeable clustering. Reinforcement of nano-WC particles improves wear resistance and frictional behavior of the composite. Hardness is seen to increase with increase in wt% of nano-particles. Wear behavior of composites depends on formation of layers over the surface mixed with oxidized debris and counter-face particles. Wear mechanism changes from adhesion to abrasion with increase in wt% of hard nano particles.
2015-09-01
hippocampal formation (Paxinos and Watson, 2005). The sections were mounted on 1% gelatin -coated slides and stored at -20°C until further histological... drying at room temperature overnight. Finally, sections were rinsed in xylene (2 times for 5 min) and coverslipped with DPX mounting media (Electron...0.1M phosphate buffered saline (3 x 5 min) and 0.1M phosphate buffer (3 x 5 min) and slides were allowed to dry for one hour before being
Adhesive Wear Performance of CFRP Multilayered Polyester Composites Under Dry/wet Contact Conditions
NASA Astrophysics Data System (ADS)
Danaelan, D.; Yousif, B. F.
The tribo-performance of a new engineering composite material based on coconut fibers was investigated. In this work, coconut fibers reinforced polyester (CFRP) composites were developed. The tribo-experiments were conducted by using pin-on-disc machine under dry and wet sliding contact condition against smooth stainless steel counterface. Worn surfaces were observed using optical microscope. Friction coefficient and specific wear rate were presented as a function of sliding distance (0-0.6 km) at different sliding velocities (0.1-0.28 m/s). The effect of applied load and sliding velocity was evaluated. The results showed that all test parameters have significant influence on friction and wear characteristics of the composites. Moreover, friction coefficient increased as the normal load and speed increased, the values were about 0.7-0.9 under dry contact condition. Meanwhile, under wet contact condition, there was a great reduction in the friction coefficient, i.e. the values were about 0.1-0.2. Furthermore, the specific wear rates were found to be around 2-4 (10-3) mm3/Nm under dry contact condition and highly reduced under wet condition. In other words, the presence of water as cleaner and polisher assisted to enhance the adhesive wear performance of CFRP by about 10%. The images from optical microscope showed evidence of adhesive wear mode with transition to abrasive wear mode at higher sliding velocities due to third body abrasion. On the other hand, optical images for wet condition showed less adhesive wear and smooth surfaces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
García, C.
Mixtures of AISI M2 high speed steel and vanadium carbide (3, 6 or 10 wt.%) were prepared by powder metallurgy and sintered by concentrated solar energy (CSE). Two different powerful solar furnaces were employed to sinter the parts and the results were compared with those obtained by conventional powder metallurgy using a tubular electric furnace. CSE allowed significant reduction of processing times and high heating rates. The wear resistance of compacts was studied by using rotating pin-on-disk and linearly reciprocating ball-on-flat methods. Wear mechanisms were investigated by means of scanning electron microscopy (SEM) observations and chemical inspections of the microstructuresmore » of the samples. Better wear properties than those obtained by conventional powder metallurgy were achieved. The refinement of the microstructure and the formation of carbonitrides were the reasons for this. - Highlights: •Powder metallurgy of mixtures of M2 high speed steel and VC are studied. •Some sintering is done by concentrated solar energy. •Rotating pin-on-disk and linearly reciprocating ball-on-flat methods are used. •The tribological properties and wear mechanisms, under dry sliding, are studied.« less
NASA Astrophysics Data System (ADS)
Faccoli, Michela; Petrogalli, Candida; Lancini, Matteo; Ghidini, Andrea; Mazzù, Angelo
2017-07-01
An experimental investigation was carried out to study and compare the response to cyclic loading of the high-performance railway wheel steels ER8 EN13262 and SUPERLOS®. Rolling contact tests were performed with the same contact pressure, rolling speed and sliding/rolling ratio, varying the lubrication regime to simulate different climatic conditions. The samples, machined out of wheel rims at two depths within the reprofiling layer, were coupled with UIC 900A rail steel samples. The wear rates, friction coefficients and hardness were correlated with the deformation beneath the contact surface. The crack morphology was studied, and the damage mechanisms were identified. The distribution of crack length and depth at the end of the dry tests was analyzed to quantify the damage. The main difference between the steels lies in the response of the external samples to dry contact: SUPERLOS® is subjected to a higher wear and lower friction coefficient than ER8, and this reduces the density of surface cracks that can propagate under wet contact conditions. The analysis of feedback data from in-service wheels confirmed the experimental results.
Gautieri, Alfonso; Pate, Monica I; Vesentini, Simone; Redaelli, Alberto; Buehler, Markus J
2012-08-09
In vertebrates, collagen tissues are the main component responsible for force transmission. In spite of the physiological importance of these phenomena, force transmission mechanisms are still not fully understood, especially at smaller scales, including in particular collagen molecules and fibrils. Here we investigate the mechanism of molecular sliding between collagen molecules within a fibril, by shearing a central molecule in a hexagonally packed bundle mimicking the collagen microfibril environment, using varied lateral distance between the molecules in both dry and solvated conditions. In vacuum, the central molecule slides under a stick-slip mechanism that is due to the characteristic surface profile of collagen molecules, enhanced by the breaking and reformation of H-bonds between neighboring collagen molecules. This mechanism is consistently observed for varied lateral separations between molecules. The high shearing force (>7 nN) found for the experimentally observed intermolecular distance (≈1.1 nm) suggests that in dry samples the fibril elongation mechanism relies almost exclusively on molecular stretching, which may explain the higher stiffnesses found in dry fibrils. When hydrated, the slip-stick behavior is observed only below 1.3 nm of lateral distance, whereas above 1.3 nm the molecule shears smoothly, showing that the water layer has a strong lubricating effect. Moreover, the average force required to shear is approximately the same in solvated as in dry conditions (≈2.5 nN), which suggests that the role of water at the intermolecular level includes the transfer of load between molecules. Copyright © 2012 Elsevier Ltd. All rights reserved.
Wear behavior of carbide tool coated with Yttria-stabilized zirconia nano particles.
NASA Astrophysics Data System (ADS)
Jadhav, Pavandatta M.; Reddy, Narala Suresh Kumar
2018-04-01
Wear mechanism takes predominant role in reducing the tool life during machining of Titanium alloy. Challenges of wear mechanisms such as variation in chip, high pressure loads and spring back are responsible for tool wear. In addition, many tool materials are inapt for machining due to low thermal conductivity and volume specific heat of these materials results in high cutting temperature during machining. To confront this issue Electrostatic Spray Coating (ESC) coating technique is utilized to enhance the tool life to an acceptable level. The Yttria Stabilized Zirconia (YSZ) acts as a thermal barrier coating having high thermal expansion coefficient and thermal shock resistance. This investigation focuses on the influence of YSZ nanocoating on the tungsten carbide tool material and improve the machinability of Ti-6Al-4V alloy. YSZ nano powder was coated on the tungsten carbide pin by using ESC technique. The coatings have been tested for wear and friction behavior by using a pin-on-disc tribological tester. The dry sliding wear test was performed on Titanium alloy (Ti-6Al-4V) disc and YSZ coated tungsten carbide (pin) at ambient atmosphere. The performance parameters like wear rate and temperature rise were considered upon performing the dry sliding test on Ti-6Al-4V alloy disc. The performance parameters were calculated by using coefficient of friction and frictional force values which were obtained from the pin on disc test. Substantial resistance to wear was achieved by the coating.
NASA Astrophysics Data System (ADS)
Yin, Cun-hong; Liang, Yi-long; Jiang, Yun; Yang, Ming; Long, Shao-lei
2017-11-01
The microstructures of 20CrNi2Mo steel underneath the contact surface were examined after dry sliding. Scanning Electronic Microscopy (SEM), Transmission Electron Microscopy (TEM), Electron Backscattered Diffraction (EBSD) and an ultra-micro-hardness tester were used to characterize the worn surface and dry sliding wear-induced layer. Martensite laths were ultra-refined due to cumulative strains and a large strain gradient that occurred during cyclic loading in wear near the surface. The microstructure evolution in dominant abrasive wear differs from that in adhesive wear. In dominant abrasive wear, only bent martensite laths with high-density deformation dislocations were observed. In contrast, in dominant adhesive wear, gradient structures were formed along the depth from the wear surface. Cross-sectional TEM foils were prepared in a focused ion beam (FIB) to observe the gradient structures in a dry sliding wear-induced layer at depths of approximately 1-5 μm and 5-20 μm. The gradient structures contained nano-laminated structures with an average thickness of 30-50 nm and bent martensite laths. We found that the original martensite laths coordinated with the strain energy and provided origin boundaries for the formation of gradient structures. Geometrically necessary boundaries (GNBs) and isolated dislocation boundaries (IDBs) play important roles in forming the nano-laminated structures.
Spontaneous Blinking from a Tribological Viewpoint.
Pult, Heiko; Tosatti, Samuele G P; Spencer, Nicholas D; Asfour, Jean-Michel; Ebenhoch, Michael; Murphy, Paul J
2015-07-01
The mechanical forces between the lid wiper and the ocular surface, and between a contact lens and the lid wiper, are reported to be related to dry eye symptoms. Furthermore, the mechanical forces between these sliding partners are assumed to be related to the ocular signs of lid-wiper epitheliopathy (LWE) and lid-parallel conjunctival folds (LIPCOF). Recent literature provides some evidence that a contact lens with a low coefficient of friction (CoF) improves wearing comfort by reducing the mechanical forces between the contact lens surface and the lid wiper. This review discusses the mechanical forces during spontaneous blinks from a tribological perspective, at both low and high sliding velocities, in a healthy subject. It concludes that the coefficient of friction of the ocular surfaces appears to be strongly comparable to that of hydrophilic polymer brushes at low sliding velocity, and that, with increased sliding velocity, there is no wear at the sliding partners' surfaces thanks to the presence of a fluid film between the two sliding partners. In contrast, in the case of dry eye, the failure to maintain a full fluid film lubrication regime at high blinking speeds may lead to increased shear rates, resulting in deformation and wear of the sliding pairs. These shear rates are most likely related to tear film viscosity. Copyright © 2015 Elsevier Inc. All rights reserved.
Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep
2014-01-01
Background: Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. Materials & Methods: In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. Results: The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. Conclusion: The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83. PMID:24876706
Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep
2014-04-01
Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83.
Effects of simulated clay gouges on the sliding behavior of Tennessee sandston
NASA Astrophysics Data System (ADS)
Shimamoto, Toshihiko; Logan, John M.
1981-06-01
The effects of simulated fault gouge on the sliding behavior of Tennessee sandstone are studied experimentally with special reference to the stabilizing effect of clay minerals mixed into the gouge. About 30 specimens with gouge composed of pure clays, of homogeneously mixed clay and anhydrite, or of layered clay and anhydrite, along a 35° precut are deformed dry in a triaxial apparatus at a confining pressure of 100 MPa, with a shortening rate of about 5 · 10 -4/sec, and at room temperature. Pure clay gouges exhibit only stable sliding, and the ultimate frictional strength is very low for bentonite (mont-morillonite), intermediate for chlorite and illite, and considerably higher for kaolinite. Anhydrite gouge shows violent stick-slip at 100 MPa confining pressure. When this mineral is mixed homogeneously with clays, the frictional coefficient of the mixed gouge, determined at its ultimate frictional strength, decreases monotonically with an increase in the clay content. The sliding mode changes from stick-slip to stable sliding when the frictional coefficient of the mixed clay-anhydrite gouge is lowered down below 90-95% of the coefficient of anhydrite gouge. The stabilizing effect of clay in mixed gouge is closely related to the ultimate frictional strength of pure clays; that is, the effect is conspicuous only for a mineral with low frictional strength. Only 15-20% of bentonite suppresses the violent stick-slip of anhydrite gouge. In contrast, violent stick-slip occurs even if the gouge contains as much as 75% of kaolinite. The behavior of illite and chlorite is intermediate between that of kaolinite and bentonite. Bentonite—anhydrite two-layer gouge exhibits stable sliding even when the bentonite content is only 5%. Thus, the presence of a thin, clay-rich layer in a fault zone stabilizes the behavior much more effectively than do the clay minerals mixed homogeneously with the gouge. This result brings out the mechanical significance of internal structures of a fault zone in understanding the effects of intrafault materials on the fault motion. Based on the present experimental results incorporated with some other experimental data, it is argued that although the stabilizing effect of montmorillonite and vermiculite is indeed remarkable at room temperature, the effect should be much less pronounced at elevated temperatures, due perhaps to the dewatering of the clays. In most geological environments where shallow earthquakes occur, the stabilizing effect of clays is probably not so conspicuous as to completely suppress the unstable motion of a fault.
Tread buildup on railroad wheels.
DOT National Transportation Integrated Search
2015-04-01
Based on the results of wheel slide tests and an inspection of wheels, the root cause of tread buildup (TBU) was identified as : wheel slide caused by excessive brake force. During the tests, TBU accumulated to the greatest heights under dry conditio...
Wear behavior of AISI 1090 steel modified by pulse plasma technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayday, Aysun; Durman, Mehmet
2012-09-06
AISI 1090 steel was pulse plasma treated (PPT) using a Molybdenum electrode. Two different pulse numbers were chosen to obtain modified layers of 20{+-}5 {mu}m thickness. The dry sliding wear studies performed on this steel with and without PPT against an alumina ball counterpart showed that the PPT improved the wear resistance. The pulse number of the PPT modified layer was found to be highly influential in imparting the wear resistance to this steel, due to enhancement of surface hardness depending on treatment time.
Investigation of Friction and Wear Properties of Electroless Ni-P-Cu Coating Under Dry Condition
NASA Astrophysics Data System (ADS)
Duari, Santanu; Mukhopadhyay, Arkadeb; Barman, Tapan Kr.; Sahoo, Prasanta
This study presents the deposition and tribological characterization of electroless Ni-P-Cu coatings deposited on AISI 1040 steel specimens. After deposition, coatings are heat treated at 500∘C for 1h. Surface morphology study of the coatings reveals its typical cauliflower like appearance. Composition study of the coatings using energy dispersive X-ray analysis indicates that the deposit lies in the high phosphorus range. The coatings undergo crystallization on heat treatment. A significant improvement in microhardness of the coatings is also observed on heat treatment due to the precipitation of hard crystalline phases. The heat-treated coatings are subjected to sliding wear tests on a pin-on-disc type tribo-tester under dry condition by varying the applied normal load, sliding speed and sliding duration. The coefficient of friction (COF) increases with an increase in the applied normal load while it decreases with an increase in the sliding speed. The wear depth on the other hand increases with an increase in applied normal load as well as sliding speed. The worn surface morphology mainly indicates fracture of the nodules.
NASA Astrophysics Data System (ADS)
Xing, Youqiang; Deng, Jianxin; Gao, Peng; Gao, Juntao; Wu, Ze
2018-04-01
Microtextures with different groove inclinations are fabricated on the AlCrN-coated surface by a nanosecond laser, and the tribological properties of the textured AlCrN samples sliding against AISI 1045 steel balls are investigated by reciprocating sliding friction tests under dry conditions. Results show that the microtextures can effectively improve the tribological properties of the AlCrN surface compared with the smooth surface. Meanwhile, the angle between the groove inclination and sliding direction has an important influence on the friction and wear properties. The textured sample with the small groove inclination may be beneficial to reducing the friction and adhesions, and the TC-0° sample exhibits the lowest friction coefficient and adhesions of the worn surface. The wear volume of the ball sliding against the TC-0° sample is smaller compared with the UTC sample and the sliding against the TC-45° and TC-90° samples is larger compared with the UTC sample. Furthermore, the mechanisms of the microtextures are discussed.
NASA Astrophysics Data System (ADS)
Lestari, W. D.; Jamari, J.; Bayuseno, A. P.
2017-04-01
The texture shapes play a key role in the tribological performance of the surface material. This paper presents a study on the use of the 3D finite element method for surface stress analysis on the different texture shape under load and dry sliding contact. The five texture-shaped model was investigated in this work, namely square, circle, ellipse, triangle, and chevron. The result shown that the square shape has the highest value of von Mises resultant stress under static load. In contrast, the dry sliding contact on the triangle shape provided the highest von Mises stress distribution. The lowest value of von Mises stress can be found in the texture pattern of circle, square, and chevron under influence of load for 17 N, 30 N, and 50 N, respectively. Those texture patterns applied to surface of Ultra High Molecular Weight Polyethylene (UHMWPE) may have a strong effect on the reduction of wear rate and enhance tribological performance.
Tribological Behavior of Plasma-Sprayed Al2O3-20 wt.%TiO2 Coating
NASA Astrophysics Data System (ADS)
Cui, Shiyu; Miao, Qiang; Liang, Wenping; Zhang, Zhigang; Xu, Yi; Ren, Beilei
2017-05-01
Al2O3-20 wt.% TiO2 ceramic coatings were deposited on the surface of Grade D steel by plasma spraying of commercially available powders. The phases and the microstructures of the coatings were investigated by x-ray diffraction and scanning electron microscopy, respectively. The Al2O3-20 wt.% TiO2 composite coating exhibited a typical inter-lamellar structure consisting of the γ-Al2O3 and the Al2TiO5 phases. The dry sliding wear behavior of the coating was examined at 20 °C using a ball-on-disk wear tester. The plasma-sprayed coating showed a low wear rate ( 4.5 × 10-6 mm3 N-1 m-1), which was <2% of that of the matrix ( 283.3 × 10-6 mm3 N-1 m-1), under a load of 15 N. In addition, the tribological behavior of the plasma-sprayed coating was analyzed by examining the microstructure after the wear tests. It was found that delamination of the Al2TiO5 phase was the main cause of the wear during the sliding wear tests. A suitable model was used to simulate the wear mechanism of the coating.
Effects of high and low temperatures on development time and mortality of house dust mite eggs.
Mahakittikun, Vanna; Boitano, John Joseph; Ninsanit, Prapakorn; Wangapai, Teerapong; Ralukruedej, Kornraphat
2011-12-01
Hatching of Dermatophagoides pteronyssinus eggs was investigated when exposed to temperatures ranging from -70 to +70°C, at varying degrees of humidity (dry and wet heat, direct sunlight) and lengths of time (seven intervals, ranging from 0.5 to 5 h). Exposure to cold was induced using a domestic refrigerator at 4°C, its freezing compartment at -10°C and a deep freezer at -20, -40 and -70°C. For each time interval, there were three slides containing 30 eggs per slide, except for sunlight (five sets of slides). After treatment, all experimental groups were kept on an open work bench for 15 days of observation at ambient room temperature (ca. 22°C) and ca. 75% relative humidity. Control groups with 10 eggs per slide, in triplicate, followed a similar protocol. An egg was considered hatched if an emerging larva was detected from a cracked shell. Results indicated that at 40°C for both dry and wet heat, approximately 80% of all eggs survived. At direct sunlight and dry heat at 50°C, the thermal death point (TDP) occurred at 3 and 5 h, respectively. At 60 and 70°C both wet and dry heat, TDP occurred almost instantaneously. Under cold conditions, only the deep freezer at -70°C was effective in preventing hatching. It may be concluded that exposure to direct sunlight for 3 h, dry/wet heat of 60 and 70°C for a minimum of 30 min, and -70°C prevent egg hatching. This study may have relevance for mite control procedures.
Rate-dependent frictional adhesion in natural and synthetic gecko setae
Gravish, Nick; Wilkinson, Matt; Sponberg, Simon; Parness, Aaron; Esparza, Noe; Soto, Daniel; Yamaguchi, Tetsuo; Broide, Michael; Cutkosky, Mark; Creton, Costantino; Autumn, Kellar
2010-01-01
Geckos owe their remarkable stickiness to millions of dry, hard setae on their toes. In this study, we discovered that gecko setae stick more strongly the faster they slide, and do not wear out after 30 000 cycles. This is surprising because friction between dry, hard, macroscopic materials typically decreases at the onset of sliding, and as velocity increases, friction continues to decrease because of a reduction in the number of interfacial contacts, due in part to wear. Gecko setae did not exhibit the decrease in adhesion or friction characteristic of a transition from static to kinetic contact mechanics. Instead, friction and adhesion forces increased at the onset of sliding and continued to increase with shear speed from 500 nm s−1 to 158 mm s−1. To explain how apparently fluid-like, wear-free dynamic friction and adhesion occur macroscopically in a dry, hard solid, we proposed a model based on a population of nanoscopic stick–slip events. In the model, contact elements are either in static contact or in the process of slipping to a new static contact. If stick–slip events are uncorrelated, the model further predicted that contact forces should increase to a critical velocity (V*) and then decrease at velocities greater than V*. We hypothesized that, like natural gecko setae, but unlike any conventional adhesive, gecko-like synthetic adhesives (GSAs) could adhere while sliding. To test the generality of our results and the validity of our model, we fabricated a GSA using a hard silicone polymer. While sliding, the GSA exhibited steady-state adhesion and velocity dependence similar to that of gecko setae. Observations at the interface indicated that macroscopically smooth sliding of the GSA emerged from randomly occurring stick–slip events in the population of flexible fibrils, confirming our model predictions. PMID:19493896
2013-06-11
Serina Diniega, JPL Systems Engineer, describes the discovery that Martian gullies that end in pits rather than fan deltas are likely caused by block of frozen carbon dioxide (dry ice) sliding down slopes on a cushion of carbon dioxide gas. The pits are formed as the "dry ice" sublimates away.
Effect of Discharge Time on Plasma Electrolytic Borocarbonitriding of Pure Iron
NASA Astrophysics Data System (ADS)
Jin, Xiaoyue; Wu, Jie; Wang, Bin; Yang, Xuan; Chen, Lin; Qu, Yao; Xue, Wenbin
The plasma electrolytic borocarbonitriding (PEB/C/N) process on pure iron was carried out in 25% borax solution with glycerine and carbamide additives under different discharge time at 360V. The morphology and structure of PEB/C/N hardened layers were analyzed by SEM and XRD. The hardness profiles of hardened layers were measured by microhardness test. Corrosion behavior of PEB/C/N layers was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Their wear performance was carried out using a pin-disc friction and wear tester under dry sliding test. The PEB/C/N samples mainly consisted of α-Fe, Fe2B, Fe3C, FeN, FeB, Fe2O3 and Fe4N phases, and the Fe2B phase was the dominant phase in the boride layer. It was found that the thickness of boride layer increased with the discharge time and reached 14μm after 60min treatment. The microhardness of the boride layer was up to 2100HV, which was much higher than that of the bare pure iron (about 150HV). After PEB/C/N treatment, the corrosion resistance of pure iron was slightly improved. The friction coefficient of PEB/C/N treated pure iron decreased to 0.129 from 0.556 of pure iron substrate. The wear rate of the PEB/C/N layer after 60min under dry sliding against ZrO2 ball was only 1/10 of that of the bare pure iron. The PEB/C/N treatment is an effective way to improve the wear behavior of pure iron.
Lowering coefficient of friction in Cu alloys with stable gradient nanostructures
Chen, Xiang; Han, Zhong; Li, Xiuyan; Lu, K.
2016-01-01
The coefficient of friction (COF) of metals is usually high, primarily because frictional contacts induce plastic deformation underneath the wear surface, resulting in surface roughening and formation of delaminating tribolayers. Lowering the COF of metals is crucial for improving the reliability and efficiency of metal contacts in engineering applications but is technically challenging. Refining the metals’ grains to nanoscale cannot reduce dry-sliding COFs, although their hardness may be elevated many times. We report that a submillimeter-thick stable gradient nanograined surface layer enables a significant reduction in the COF of a Cu alloy under high-load dry sliding, from 0.64 (coarse-grained samples) to 0.29, which is smaller than the COFs of many ceramics. The unprecedented stable low COF stems from effective suppression of sliding-induced surface roughening and formation of delaminating tribolayer, owing to the stable gradient nanostructures that can accommodate large plastic strains under repeated sliding for more than 30,000 cycles. PMID:27957545
Berradja, Abdenacer; Willems, Guy; Celis, Jean-Pierre
2006-05-01
To evaluate the frictional behaviour of orthodontic archwires in dry and wet conditions in-vitro. Two types of archwire materials were investigated: stainless steel and NiTi. A fretting wear tribometer fitted with an alumina ball was operated at 23 degrees C in three different environments: ambient air with 50 per cent relative humidity, 0.9 wt. per cent sodium chloride solution, and deionised water. NiTi archwires sliding against alumina exhibited high coefficients of friction (about 0.6) in the three environments. Stainless steel archwires sliding against alumina had relatively low coefficients of friction (0.3) in the solutions, but high coefficients (0.8) in air. The low frictional forces of the stainless steel wires sliding against alumina in the solutions were due to a lubricating effect of the solutions and corrosion-wear debris. The high frictional forces between the NiTi wires and alumina are attributed to an abrasive interfacial transfer film between the wires and alumina.
NASA Astrophysics Data System (ADS)
Panin, S. V.; Kornienko, L. A.; Alexenko, V. O.; Qitao, Huang; Ivanova, L. R.
2016-11-01
Mechanical and tribotechnical properties of UHMWPE composites reinforced with basalt fibers and particles under dry sliding friction and abrasion were investigated. It is shown that adding of the basalt particles provides higher wear resistance under the dry sliding friction while at abrasion filling by the basalt fibers is more efficient since the wear resistance of the reinforced UHMWPE composites is by 3.7 times higher in contrast with the neat polymer. Wear mechanisms of the polymeric UHMWPE composites under various types of wear are discussed.
Do Cells from the Fetus Contribute to Breast Cancer
2009-09-01
extract the DNA from the tissue samples the slides were first deparaffinized and rehydrated using descending alcohol concentrations: Xylene for 2x10 min...then 100%, 95%, 70% and 50% ethanol treatments each for 10 min. The slides were dried under nitrogen to prevent oxydation . 5
Wear of Selected Oxide Ceramics and Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Sayir, A.; Farmer, S. C.
2005-01-01
The use of oxide ceramics and coatings for moving mechanical components operating in high-temperature, oxidizing environments creates a need to define the tribological performance and durability of these materials. Results of research focusing on the wear behavior and properties of Al2O3/ZrO2 (Y2O3) eutectics and coatings under dry sliding conditions are discussed. The importance of microstructure and composition on wear properties of directionally solidified oxide eutectics is illustrated. Wear data of selected oxide-, nitride-, and carbide-based ceramics and coatings are given for temperatures up to 973K in air.
NASA Technical Reports Server (NTRS)
Johnson, Robert L; Swikert, Max A; Bisson, Edmond E
1952-01-01
An investigation of wear and friction properties of a number of materials sliding against SAE 52100 steel was conducted. These materials included brass, bronze, beryllium copper, monel, nichrome v, 24s-t aluminum, nodular iron, and gray cast iron. The metals investigated may be useful as possible cage (separator or retainer) materials for rolling-contact bearings of high-speed turbine engines. The ability of materials to form surface films that prevent welding is a most important factor in both dry friction and boundary lubrication. On the basis of wear and resistance to welding only, the cast irons were the most promising materials investigated; they showed the least wear and the least tendency to surface failure when run dry, and when boundary lubricated they showed the highest load capacity. On the basis of mechanical properties, nodular iron is superior to gray cast iron. Bronze had the lowest friction coefficient under dry sliding conditions. The results with brass, beryllium copper, and aluminum were poor and these materials do not appear, with regard to friction and wear, to be suitable for cages.
Dry sliding wear system response of ferritic and tempered martensitic ductile iron
NASA Astrophysics Data System (ADS)
Jha, V. K.; Mozumder, Y. H.; Shama, S.; Behera, R. K.; Pattaniak, A.; P, Sindhoora L.; Mishra, S. C.; Sen, S.
2015-02-01
Spheroidal graphite cast iron (SG iron) is the most preferable member of cast iron family due to its strength and toughness along with good tribological properties. SG iron specimens with annealed and martensitic matrix were subjected to dry sliding wear condition and the system response was correlated to matrix microstructure. Respective microstructure was obtained by annealing and quench and tempering heat treatment process for an austenitizing temperature of 1000°C. Specimens were subjected to Ball on plate wear tester under 40N, 50N, 60N load for a sliding distance of 7.54m. Except for quench and tempered specimen at 50N, weight loss was observed in every condition. The wear surface under optical microscope reveals adhesive mechanism for as-cast and annealed specimen whereas delaminated wear track feature was observed for quench and tempered specimen.
Friction and wear of plasma-deposited diamond films
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Wu, Richard L. C.; Garscadden, Alan; Barnes, Paul N.; Jackson, Howard E.
1993-01-01
Reciprocating sliding friction experiments in humid air and in dry nitrogen and unidirectional sliding friction experiments in ultrahigh vacuum were conducted with a natural diamond pin in contact with microwave-plasma-deposited diamond films. Diamond films with a surface roughness (R rms) ranging from 15 to 160 nm were produced by microwave-plasma-assisted chemical vapor deposition. In humid air and in dry nitrogen, abrasion occurred when the diamond pin made grooves in the surfaces of diamond films, and thus the initial coefficients of friction increased with increasing initial surface roughness. The equilibrium coefficients of friction were independent of the initial surface roughness of the diamond films. In vacuum the friction for diamond films contacting a diamond pin arose primarily from adhesion between the sliding surfaces. In these cases, the initial and equilibrium coefficients of friction were independent of the initial surface roughness of the diamond films. The equilibrium coefficients of friction were 0.02 to 0.04 in humid air and in dry nitrogen, but 1.5 to 1.8 in vacuum. The wear factor of the diamond films depended on the initial surface roughness, regardless of environment; it increased with increasing initial surface roughness. The wear factors were considerably higher in vacuum than in humid air and in dry nitrogen.
Sliding-surface-liquefaction of sand-dry ice mixture and submarine landslides
NASA Astrophysics Data System (ADS)
Fukuoka, H.; Tsukui, A.
2010-12-01
In the historic records of off-shore mega-earthquakes along the subduction zone offshore Japan, there are a lot of witnesses about large-scale burning of flammable gas possibly ejected from sea floor. This gas was supposed to be the dissolved methane hydrates (MH), which have been found in the soundings of IODP and other oceanology projects. Since the vast distribution of the BSR in the continental margins, a lot of papers have been published which pointed out the possibilities of that gasification of those hydrates could have triggered gigantic submarine landslides. Global warming or large earthquake or magma intrusion may trigger extremely deep gigantic landslides in continental margins that which could cause catastrophic tsunami. However, recent triaxial compression tests on artificially prepared sand-MH-mixture samples revealed that the they have slightly higher strength than the ones of only sands and MH’s endothermal characteristics may resist against accelerating shear and large-displacement landslides as well. While, the stress-controlled undrained ring shear apparatuses have been developed by Sassa and Fukuoka at Disaster Prevention Research Institute, Kyoto University to reproduce subaerial landslides induced by earthquakes and rainfalls. Using the apparatuses, they found localized liquefaction phenomenon along the deep saturated potential sliding surface due to excess pore pressure generation during the grain crushing induced bulk volume change. This phenomenon was named as “sliding surface liquefaction.” Similar sudden large pore pressure generation was observed in pore pressure control test simulating rain-induced landslides. In this paper, authors examined the shear behavior of the dry sand-dry ice mixture under constant normal stress and shear speed control tests using the latest ring shear apparatus. Sample was mixture of silica sands and dry-ice pellets (frozen carbon-dioxide). Those mixtures are often used for studying the mechanism of the methane hydrates in laboratories because no explosion protection facility is required. In order to prevent rapid gasification, the specimen was prepared without water. Applied total normal stress was 200 kPa and initial normal stress was maintained at about 70 kPa by slightly opening the drainage valve to vent pressured CO2 gas. When the sample was sheared at 30 cm/s, the stress path reached failure line of friction angle of about 37 degrees immediately. However, excess pore air pressure increased soon after and the stress path moved to the origin along the failure line. This means rapid shearing generates frictional heat and it accelerates the gasification of dry ice quickly. On the other hand, crushing of pellets may contribute to increase the total surface area of dry ice and to acceleration of gasification, to some extent. Authors are conducting to examine the velocity weakening characteristics of the samples and upcoming results will give more detail of the mechanism. But this sliding-surface-liquefaction in the mixture supports the possibility of similar accelerating displacement in the sand-MH mixture or boundaries between MH and sand layer induced by certain strong ground motion under sea floor.
Frictional slip of granite at hydrothermal conditions
Blanpied, M.L.; Lockner, D.A.; Byerlee, J.D.
1995-01-01
To measure the strength, sliding behavior, and friction constitutive properties of faults at hydrothermal conditions, laboratory granite faults containing a layer of granite powder (simulated gouge) were slid. The mechanical results define two regimes. The first regime includes dry granite up to at least 845?? and wet granite below 250??C. In this regime the coefficient of friction is high (?? = 0.7 to 0.8) and depends only modestly on temperature, slip rate, and PH2O. The second regime includes wet granite above ~350??C. In this regime friction decreases considerably with increasing temperature (temperature weakening) and with decreasing slip rate (velocity strengthening). These regimes correspond well to those identified in sliding tests on ultrafine quartz. The results highlight the importance of fluid-assisted deformation processes active in faults at depth and the need for laboratory studies on the roles of additional factors such as fluid chemistry, large displacements, higher concentrations of phyllosilicates, and time-dependent fault healing. -from Authors
Research on Oxidation Wear Behavior of a New Hot Forging Die Steel
NASA Astrophysics Data System (ADS)
Shi, Yuanji; Wu, Xiaochun
2018-01-01
Dry sliding tests for the hot forging die steel DM were performed in air under the test temperature at 400-700 °C and the time of 0.5-4 h by a UMT-3 high-temperature wear tester. The wear behavior and characteristics were studied systematically to explore the general characters in severe oxidation conditions. The results showed that a mild-to-severe oxidation wear transition occurred with an increase in the test temperature and duration. The reason was clarified as the unstable M6C carbides coarsening should be responsible for the severe delamination of tribo-oxide layer. More importantly, an intense oxidation wear with lower wear rates was found when the experimental temperature reaches 700 °C or after 4 h of test time at 600 °C, which was closely related to the degradation behavior during wear test. Furthermore, a new schematic diagram of oxidation wear of DM steel was proposed.
Evidence of Self-Organized Criticality in Dry Sliding Friction
NASA Technical Reports Server (NTRS)
Zypman, Fredy R.; Ferrante, John; Jansen, Mark; Scanlon, Kathleen; Abel, Phillip
2003-01-01
This letter presents experimental results on unlubricated friction, which suggests that stick-slip is described by self-organized criticality (SOC). The data, obtained with a pin-on-disc tribometer examines the variation of the friction force as a function of time-or sliding distance. This is the first time that standard tribological equipment has been used to examine the possibility of SOC. The materials were matching pins and discs of aluminium loaded with 250, 500 and 1000 g masses, and matching M50 steel couples loaded with a 1000 g mass. An analysis of the data shows that the probability distribution of slip sizes follows a power law. We perform a careful analysis of all the properties, beyond the two just mentioned, which are required to imply the presence of SOC. Our data strongly support the existence of SOC for stick-slip in dry sliding friction.
Development of a standardized testing system for orthodontic sliding mechanics.
Fathimani, Maryam; Melenka, Garrett W; Romanyk, Dan L; Toogood, Roger W; Heo, Giseon; Carey, Jason P; Major, Paul W
2015-01-01
The primary objective of this study was to develop a computer-controlled three-dimensional friction measuring system, the orthodontic friction simulator (OFS). A clinically-based in vitro experiment considering wet and dry friction for conventionally and self-ligated brackets is presented to elucidate debate surrounding sliding mechanics and illustrate capabilities of the OFS. The OFS was designed and manufactured using sound engineering principles and with the primary concern of being able to measure all forces and moments generated during sliding mechanics. This required the implementation of a six-axis load cell. A variety of translation and rotation stages were also incorporated to allow for precise positioning of the bracket relative to the archwire. Once designed and built, the OFS was then used to compare conventional and self-ligation methods in both the wet and dry state. Damon Q brackets and 0.018″ × 0.025″ stainless steel wires were used for all tests with a sample size of n = 65 for each ligation method. Archwires were pulled at a speed of 0.1 mm/s in 11 increments of 0.1 mm. At each increment, the bracket would be rotated 0.5° resulting in a total archwire travel of 1.1 mm and a second-order bracket angle range of 0°-5°. A repeated measures ANOVA was conducted to determine if ligation method and/or addition of moisture effected resulting orthodontic loads. The developed equipment for studying orthodontic sliding mechanics was able to measure forces and moments in all three directions; a capability not previously realized in the literature. Additionally, it was found that passive ligation significantly reduced resistance to sliding, P ≤ 0.05, while the dry/wet state did not. The OFS certainly proved to be an adequate instrument for the scientific evaluation of orthodontic sliding mechanics. It is capable of measuring loads generated in all directions and is a fully automated apparatus allowing for simple and repeatable friction tests to be conducted. Furthermore, the addition of saliva was not found to significantly influence the loads generated during sliding mechanics regardless of ligation method.
Experiments on vibration-driven stick-slip locomotion: A sliding bifurcation perspective
NASA Astrophysics Data System (ADS)
Du, Zhouwei; Fang, Hongbin; Zhan, Xiong; Xu, Jian
2018-05-01
Dry friction appears at the contact interface between two surfaces and is the source of stick-slip vibrations. Instead of being a negative factor, dry friction is essential for vibration-driven locomotion system to take effect. However, the dry-friction-induced stick-slip locomotion has not been fully understood in previous research, especially in terms of experiments. In this paper, we experimentally study the stick-slip dynamics of a vibration-driven locomotion system from a sliding bifurcation perspective. To this end, we first design and build a vibration-driven locomotion prototype based on an internal piezoelectric cantilever. By utilizing the mechanical resonance, the small piezoelectric deformation is significantly amplified to drive the prototype to achieve effective locomotion. Through identifying the stick-slip characteristics in velocity histories, we could categorize the system's locomotion into four types and obtain a stick-slip categorization diagram. In each zone of the diagram the locomotion exhibits qualitatively different stick-slip dynamics. Such categorization diagram is actually a sliding bifurcation diagram; crossing from one stick-slip zone to another corresponds to the triggering of a sliding bifurcation. In addition, a simplified single degree-of-freedom model is established, with the rationality of simplification been explained theoretically and numerically. Based on the equivalent model, a numerical stick-slip categorization is also obtained, which shows good agreement with the experiments both qualitatively and quantitatively. To the best of our knowledge, this is the first work that experimentally generates a sliding bifurcation diagram. The obtained stick-slip categorizations deepen our understanding of stick-slip dynamics in vibration-driven systems and could serve as a base for system design and optimization.
NASA Astrophysics Data System (ADS)
Mehrishal, Seyedahmad; Sharifzadeh, Mostafa; Shahriar, Korosh; Song, Jae-Jon
2016-12-01
Among all parameters that affect the friction of rocks, variable normal stress and slip rate are the most important second-order parameters. The shear-rate- and normal-stress-dependent friction behavior of rock discontinuities may significantly influence the dynamic responses of rock mass. In this research, two limestone rock types, which were travertine and onyx marble with slickenside and grinded #80 surfaces, were prepared and CNL direct shear tests were performed on the joints under various shear conditions. The shearing rate varied from 0.1 to 50 mm/min under different normal stresses (from 2 to 30 % of UCS) in both dry and wet conditions. Experiments showed that the friction coefficient of slickensided and ground #80 surfaces of limestone increased with the increasing shear velocity and decreased with the increasing normal stress. Micro-asperity interlocking between ground #80 surfaces showed higher wear and an increase in friction coefficient ( µ) compared to slickensided surfaces. Slickensided samples with moist surfaces showed an increase in the coefficient of friction compared to dry surfaces; however, on ground #80 surfaces, the moisture decreased the coefficient of friction to a smaller value. Slickenside of limestone typically slides stably in a dry condition and by stick-slip on moist surfaces. The observed shear-rate- and normal-stress-dependent friction behavior can be explained by a similar framework to that of the adhesion theory of friction and a friction mechanism that involves the competition between microscopic dilatant slip and surface asperity deformation. The results have important implications for understanding the behavior of basic and residual friction coefficients of limestone rock surfaces.
NASA Astrophysics Data System (ADS)
An, J.; Xuan, X. H.; Zhao, J.; Sun, W.; Liang, C.
2016-12-01
The wear properties of Mg97Zn1Y2 alloy were investigated using the pin-on-disk wear machine within a load range of 20-380 N and a sliding speed range of 0.2-4.0 m/s. Analysis of worn surfaces using scanning electron microscope and energy-dispersive x-ray spectrometer revealed that wear mechanisms including abrasion + oxidation, delamination accompanied by heavy surface oxidation and delamination operated in mild wear regime, while wear mechanisms such as severe plastic deformation, severe plastic deformation accompanied by spallation of oxidation layer and surface melting prevailed in severe wear regime. The microstructural evolution and hardness change in subsurfaces were examined by optical microscopy and hardness tester. The transformation of surface material from the deformed into dynamic recrystallization (DRX) microstructure was observed before and after mild-to-severe transition. The reason for mild-to-severe wear transition was identified as the transformation of strain hardening to DRX softening in subsurface. Mg97Zn1Y2 alloy has a superior mild-to-severe wear transition resistance to AZ alloys because of its higher recrystallization temperature. A novel model for evaluating the critical surface temperature of mild-to-severe wear transition was established using DRX kinetics.
Tribological studies of a Zr-based bulk metallic glass with different states
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Feng; Qu, Jun; Fan, Guojiang
The tribological characteristics of a bulk-metallic glass (BMG) Zr52.5Cu17.9Ni14.6Al10.0Ti5.0 (Vit 105) with different states have been studied. Friction and wear tests were conducted using a ball-on-flat reciprocating sliding apparatus against AISI E52100 bearing steel under dry condition. The observed wear resistance in an ascending order is deformed, crept, relaxed, and as-cast. Results suggested that the wear process of BMG alloys involved abrasion, adhesion, and oxidation. The differences in hardness, free volume, and embrittlement at different states significantly affected the friction and wear behaviors of the BMG alloys.
Mechanism of lubrication by tricresylphosphate (TCP)
NASA Technical Reports Server (NTRS)
Faut, O. D.; Buckley, D. H.
1984-01-01
The coefficient of friction was measured as a function of temperature on a pin-on-disk tribometer. Pins and disks of 440C and 52100 steels were lubricated with tricresylphosphate (TCP), 3.45 percent TCP in squalene, and pure squalene. The M-50 pins and disks were lubricated with 3.45 percent TCP in squalene and pure squalene. Experiments were conducted under limited lubrication conditions in dry ( 100 ppm H2O) air and dry ( pp H2O) nitrogen at 50 rpm (equivalent to a sliding velocity of 13 cm sec) and a constant load of 9.8 N (1 kg). Characteristic temperatures T sub r were identified for TCP on 52100 steel and for squalene on M-50 and 52100 steels, where the friction decreased because of a chemical reaction between the lubricant and the metal surface. The behavior of squalene obscured the influence of 3.45 percent TCP solute on the friction of the system. Wear volume measurements demonstrated that wear was lowest at temperatures just above T sub r. Comparing the behavior of TCP on M-50, 440C, and 52100 steels revealed that the TCP either reacted to give T sub r behavior or produced initial failure in the temperature range 223 + or - 5 C.
Sliding Wear and Fretting Wear of DLC-Based, Functionally Graded Nanocomposite Coatings
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Pohlchuck, B.; Street, Kenneth W.; Zabinski, J. S.; Sanders, J. H.; Voevodin, A. a.; Wu, R. L. C.
1999-01-01
Improving the tribological functionality of diamondlike carbon (DLC) films--developing, good wear resistance, low friction, and high load-carrying capacity-was the aim of this investigation. Nanocomposite coatings consisting of an amorphous DLC (a-DLC) top layer and a functionally graded titanium-titanium carbon-diamondlike carbon (Ti-Ti(sub x) C(sub y)-DLC) underlayer were produced on AISI 440C stainless steel substrates by the hybrid technique of magnetron sputtering and pulsed-laser deposition. The resultant DLC films were characterized by Raman spectroscopy, scanning electron microscopy, and surface profilometry. Two types of wear experiment were conducted in this investioation: sliding friction experiments and fretting wear experiments. Unidirectional ball-on-disk sliding friction experiments were conducted to examine the wear behavior of an a-DLC/Ti-Ti(sub x) C(sub y)-DLC-coated AISI 440C stainless steel disk in sliding contact with a 6-mm-diameter AISI 440C stainless steel ball in ultrahigh vacuum, dry nitrogen, and humid air. Although the wear rates for both the coating and ball were low in all three environments, the humid air and dry nitrogen caused mild wear with burnishing, in the a-DLC top layer, and the ultrahigh vacuum caused relatively severe wear with brittle fracture in both the a-DLC top layer and the Ti-Ti(sub x) C(sub y)-DLC underlayer. For reference, amorphous hydrogenated carbon (H-DLC) films produced on a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coatings by using an ion beam were also examined in the same manner. The H-DLC films markedly reduced friction even in ultrahigh vacuum without sacrificing wear resistance. The H-DLC films behaved much like the a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coating in dry nitrogen and humid air, presenting low friction and low wear. Fretting wear experiments were conducted in humid air (approximately 50% relative humidity) at a frequency of 80 Hz and an amplitude of 75 micron on an a-DLC/Ti-Ti(sub x) C(sub y)-DLC-coated AISI 440C disk and on a titanium-6 wt % aluminum-4 wt% vanadium (Ti-6Al-4V) flat, both in contact with a 9.4-mm-diameter, hemispherical Ti-6Al-4V pin. The resistance to fretting wear and damage of the a-DLC/Ti-6Al-4V materials pair was superior to that of the Ti-6Al-4V/Ti-6AI-4V materials pair.
Dynamic weakening is limited by granular dynamics
NASA Astrophysics Data System (ADS)
Kuwano, O.; Hatano, T.
2011-12-01
Earthquakes are the result of the frictional instability of faults containing fine rock powders called gouge derived from attrition in past fault motions. Understanding the frictional instability of granular matter in terms of constitutive laws is thus important. Because of the importance of granular matter for industries and engineering, the friction of granular matter has been studied in the field of solid earth science and other fields, such as statistical physics. In solid earth science, the rate- and state-dependent friction law was established by laboratory experiments at a very low sliding velocity (μm/s to mm/s). Recent experiments conducted at sub-seismic to seismic sliding velocities (mm/s to m/s), however, show that frictional properties are much richer than those predicted by the rate- and state-dependent friction law. One of the most important findings in such experiments is the remarkable weakening due to mechano-chemical effects by frictional heating [Tullis, 2007]. In statistical physics, another empirical law holds for much faster deformation than the former, showing positive shear-rate dependence. Until Recently, friction of granular matter has been investigated independently in the fields of solid earth science and statistical physics, and thus the relation between these distinct constitutive laws is not clear. Recently, some experimental studies have been reported to connect the achievements in these two fields. For example, a laboratory experiment on dry glass beads under very low normal stress (0.02 to 0.05 MPa) in which the frictional heat is negligible reveals the transition from velocity-weakening friction at low sliding velocities to velocity-strengthening friction at high sliding velocities [Kuwano et al., 2011]. Importantly, the velocity-strengthening nature at high sliding velocities is quantitatively the same as those observed in simulations. The inelastic deformation of the grains therefore plays a vital role at high sliding velocities. In this study, we report a friction experiment under higher pressure (0.1 to 0.9 MPa), in which the frictional heat is significant. To clarify the effect of frictional heat in high-speed friction systematically, we investigated both the pressure and the velocity dependence of the friction coefficient over a wide range of sliding velocities ranging from aseismic to seismic slip velocities. We observed considerable weakening, described well by a flash-heating theory, above the sliding velocity of 1 cm/s regardless of pressure. At higher velocities, the velocity strengthening behavior replaced the velocity weakening behavior. This strengthening at higher velocities agrees with data from numerical simulations on sheared granular matter and is therefore described in terms of energy dissipation due to the inelastic deformation of grains. We propose a unified steady-state friction law that well describes the velocity and pressure dependence of the steady-state friction coefficient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mbamara, U. S.; Olofinjana, B.; Ajayi, O. O.
Most researches on doped ZnO thin films are tilted toward their applications in optoelectronics and semiconductor devices. Research on their tribological properties is still unfolding. In this work, nitrogen-doped ZnO thin films were deposited on 304 L stainless steel substrate from a combination of zinc acetate and ammonium acetate precursor by MOCVD technique. Compositional and structural studies of the films were done using Rutherford Backscattering Spectroscopy (RBS) and X-ray Diffraction (XRD). The frictional behavior of the thin film coatings was evaluated using a ball-on-flat configuration in reciprocating sliding under dry contact condition. After friction test, the flat and ball counter-facemore » surfaces were examined to assess the wear dimension and failure mechanism. In conclusion, both friction behavior and wear (in the ball counter-face) were observed to be dependent on the crystallinity and thickness of the thin film coatings.« less
The nucleation of "fast" and "slow" stick slip instabilities in sheared granular aggregates
NASA Astrophysics Data System (ADS)
Korkolis, Evangelos; Ampuero, Jean-Paul; Niemeijer, André
2017-04-01
Seismological observations in the past few decades have revealed a diversity of slip behaviors of faults, involving interactions and transition between slow to fast slip phenomena. Field studies show that exhumed fault zones comprise mixtures of materials with variable frictional strength and stability. Emergent models of slip diversity emphasize the role of heterogeneities of fault zone properties and the potential interactions between seismic and aseismic deformation. Here, we develop analog laboratory experiments to study the mechanics of heterogeneous faults with the goal to identify factors controlling their slip stability and rupture style. We report on results from room temperature sliding experiments using a rotary shear apparatus. We simulated gouge heterogeneity by using materials with different frictional strength and stability. At room temperature conditions, dry glass beads typically stick slip, whereas dry granular calcite exhibits stable sliding. The peak strength of glass beads aggregates is typically lower than that of granular calcite aggregates. Our samples consisted of a layer of glass beads sandwiched between two layers of granular calcite. The initial particle size was between 100 and 200 μm for both materials and the initial thickness of each layer was about 1.5 mm. We tested our layered aggregates under 1 to 7 MPa normal stress and at sliding velocities between 1 and 100 μm/s. Within that range of conditions, high normal stress and slow sliding velocities promoted fast, regular stick slip. For normal stress values of less than about 4 MPa, the recurrence time and stress drop of stick slips became irregular, particularly at sliding rates above 20 μm/s. As the accumulated shear displacement increased, slip events became slower and the magnitudes of their stress drop, compaction and slip distance decreased. We recorded acoustic emissions (AEs) associated with each slip event (fast and slow) and estimated their source azimuth. AE activity was distributed in several clusters, some of which remained stationary, whereas others appeared to migrate with increasing shear displacement. We performed post-mortem microstructural analysis (tabletop SEM) of select AE nucleation sites and found significant mixing of glass beads with the calcite layer abutting the rotating piston ring. No mixing was observed between the glass beads and the calcite layer on the opposite side, nor any features that would indicate strain localization along the interface of the calcite and the adjacent stationary piston. These results show that the frictional behavior of our aggregates changed from fast to slow slip as the amount of glass beads mixed with granular calcite increased. Migrating AE clusters imply that nucleation occurred within the mixed calcite-glass beads layer, where most of the shear strain appears to have been accommodated, whereas stationary clusters probably originated within the adjacent, more slowly deforming layer of glass beads. This suggests that AEs belonging to migrating clusters were perhaps triggered by stress changes due to the gradual mixing of the two sample constituents. This process may explain migrating seismicity in natural fault zones.
NASA Astrophysics Data System (ADS)
Emge, Andrew
The unlubricated sliding of metals is important in many mechanical devices covering a wide range of sliding velocities. However, the effect of sliding velocity on the tribological behavior of unlubricated metals has not been widely studied. Similarly, the relationship between microstructures developed at high sliding velocities and tribological behavior has not been studied in depth. Microstructures produced at low sliding velocities have been studied extensively and commonly include nanocrystalline or fine grained material near the sliding surface with heavily deformed microstructures further from the surface. The current research relates two aspects of the sliding friction of ductile metals, the effect of sliding velocity and the production of nanocrystalline tribomaterial. The project focused on the effects of sliding velocity on the frictional behavior of oxygen free high conductivity (OFHC) copper sliding against 440C stainless steel, Nitronic 40 stainless steel, and copper. Low velocity tests were performed with a pin on disk tribometer. High velocity tests were performed with a rotating barrel gas gun (RBGG) which combined impact with sliding. The RBGG provides sliding velocities as high as 5.5 m/s and impact velocities as high as 12 m/s while maintaining sliding times on the order of tens of microseconds. Changes in the coefficient of friction, microstructure, and composition were studied. Surface and subsurface microstructures of the worn samples were characterized with a range of instruments including scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), focused ion beam (FIB) milling and imaging, transmission electron microscopy (TEM) with EDS, orientation imaging microscopy (OIM), and nanoindentation. In the case of self-mated copper the sliding velocity had little effect on the coefficient of friction for both experimental apparatuses. For the case of copper sliding against 440C stainless steel on the pin on disk system the friction was found to increase with sliding velocity and was strongly influenced by material transfer from the copper to the steel pin. An increase in the coefficient of friction with sliding velocity was observed for the sliding of OFHC copper against Nitronic 40 steel in RBGG tests. The increase in the coefficient of friction was correlated to an increase in subsurface plastic deformation and grain refinement. The growth of the nanocrystalline tribolayer in copper after sliding against 440C stainless steel at varying times was studied at sliding velocities of 0.05 and 1.0 m/s. A sliding velocity of 0.05 m/s produced a consistent nanocrystalline layer in as little as 10 s. The thickness of the nanocrystalline layer grew to an average thickness of 3 microm after 10 ks of sliding, but large variations in thickness were observed. A sliding velocity of 1.0 m/s produced a continuous nanocrystalline layer after 10 s of sliding. Ledges developed on the wear tracks at longer sliding times which greatly influenced the tribolayer thickness making it difficult to quantify. Dynamic recrystallization of the tribolayer also led to difficulties in measuring its thickness.
Structure and morphology of submarine slab slides: clues to origin and behavior
O'Leary, Dennis W.
1991-01-01
Geologic features suggest that some slab slides probably result from long-term strength degradation of weak layers deep in the homoclinal section. Time-dependent strain in clay-rich layers can create potential slide surfaces of low frictional strength. Competent layers are weak in tension and probably fragment in the first instance of, or even prior to, translation, and the allochthonous mass is readily transformed into a high-momentum debris flow. The structure and geomorphology of slab slides provide important clues to their origin and behavior. -from Author
Microstructure and dry-sliding wear properties of DC plasma nitrided 17-4 PH stainless steel
NASA Astrophysics Data System (ADS)
Li, Gui-jiang; Wang, Jun; Li, Cong; Peng, Qian; Gao, Jian; Shen, Bao-luo
2008-05-01
An attempt that the precipitation hardening steel 17-4PH was conducted by DC plasma nitriding (DCPN) is made to develop a kind of candidate material for nuclear reactor. Nitriding process performed at temperature ⩽ 400 °C takes effect on creation of the layers composed of S-phase (expanded austenite) and αN‧ (expanded martensite). Up to the temperature of 420 °C, the S-phase peaks disappear due to the transformation occurrence (S-phase → αN‧ + CrN). For the samples nitrided at temperature ⩾ 450 °C, no evidence of αN‧ is found owing to a precipitation (αN‧ → α +CrN) taking place. For the 480 °C/4 h treated sample, it is the surface microhardness that plays the lead role in the wear rate reduction but the surface roughness; while for the 400 °C/4 h treated sample, it is both of the surface roughness and the S-phase formation. Dry sliding wear of the untreated 17-4PH is mainly characterized by strong adhesion, abrasion and oxidation mechanism. Samples nitrided at 400 °C which is dominated by slight abrasion and plastic deformation exhibit the best dry sliding wear resistance compared to the samples nitrided at other temperatures.
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Wu, Richard L. C.; Lanter, William C.
1996-01-01
Friction and wear behavior of ion-beam-deposited diamondlike carbon (DLC) films coated on chemical-vapor-deposited (CVD), fine-grain diamond coatings were examined in ultrahigh vacuum, dry nitrogen, and humid air environments. The DLC films were produced by the direct impact of an ion beam (composed of a 3:17 mixture of Ar and CH4) at ion energies of 1500 and 700 eV and an RF power of 99 W. Sliding friction experiments were conducted with hemispherical CVD diamond pins sliding on four different carbon-base coating systems: DLC films on CVD diamond; DLC films on silicon; as-deposited, fine-grain CVD diamond; and carbon-ion-implanted, fine-grain CVD diamond on silicon. Results indicate that in ultrahigh vacuum the ion-beam-deposited DLC films on fine-grain CVD diamond (similar to the ion-implanted CVD diamond) greatly decrease both the friction and wear of fine-grain CVD diamond films and provide solid lubrication. In dry nitrogen and in humid air, ion-beam-deposited DLC films on fine-grain CVD diamond films also had a low steady-state coefficient of friction and a low wear rate. These tribological performance benefits, coupled with a wider range of coating thicknesses, led to longer endurance life and improved wear resistance for the DLC deposited on fine-grain CVD diamond in comparison to the ion-implanted diamond films. Thus, DLC deposited on fine-grain CVD diamond films can be an effective wear-resistant, lubricating coating regardless of environment.
NASA Astrophysics Data System (ADS)
Wang, Jun; Lin, Yuanhua; Zeng, Dezhi; Yan, Jing; Fan, Hongyuan
2013-04-01
The effects of process parameters on the microstructure, microhardness, and dry-sliding wear behavior of plasma nitrided 17-4PH stainless steel were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and wear testing. The results show that a wear-resistant nitrided layer was formed on the surface of direct current plasma nitrided 17-4PH martensitic stainless steel. The microstructure and thickness of the nitrided layer is dependent on the treatment temperature rather than process pressure. XRD indicated that a single α N phase was formed during nitriding at 623 K (350 °C). When the temperature increased, the α N phase disappeared and CrN transformed in the nitrided layer. The hardness measurement demonstrated that the hardness of the stainless substrate steel increased from 320 HV0.1 in the untreated condition increasing to about 1275HV0.1 after nitriding 623 K (350 °C)/600 pa/4 hours. The extremely high values of the microhardness achieved by the great misfit-induced stress fields associated with the plenty of dislocation group and stacking fault. Dry-sliding wear resistance was improved by DC plasma nitriding. The best wear-resistance performance of a nitrided sample was obtained after nitriding at 673 K (350 °C), when the single α N-phase was produced and there were no CrN precipitates in the nitrided layer.
NASA Astrophysics Data System (ADS)
Karamış, M. B.; Yıldızlı, K.; Çakırer, H.
2004-05-01
Surface properties of the Al-Mo-Ni coating plasma sprayed on the piston ring material and the frictional forces obtained by testing carried out under different loads, temperatures and frictional conditions were evaluated. Al-Mo-Ni composite material was deposited on the AISI 440C test steel using plasma spraying method. The coated and uncoated samples were tested by being exposed to frictional testing under dry and lubricated conditions. Test temperatures of 25, 100, 200, and 300 °C and loads of 83, 100, 200, and 300 N were applied during the tests in order to obtain the frictional response of the coating under conditions similar to real piston ring/cylinder friction conditions. Gray cast iron was used as a counterface material. All the tests were carried out with a constant sliding speed of 1 m/s. The properties of the coating were determined by using EDX and SEM analyses. Hardness distribution on the cross-section of the coating was also determined. In addition, the variations of the surface roughness after testing with test temperatures and loads under dry and lubricated conditions were recorded versus sliding distance. It was determined that the surface roughness increased with increasing loads. It increased with temperature up to 200 °C and then decreased at 300 °C under dry test conditions. Under lubricated conditions, the roughness decreased under the loads of 100 N and then increased. The roughness decreased at 200 °C but below and above this point it increased with the test temperature. Frictional forces observed under dry and lubricated test conditions increased with load at running-in period of the sliding. The steady-state period was then established with the sliding distance as a normal situation. However, the frictional forces were generally lower at a higher test temperature than those at a lower test temperature. Surprisingly, the test temperature of 200 °C was a critical point for frictional forces and surface roughness.
Özel, Cihan; Gürgenç, Turan
2018-01-01
In this study, AISI 1020 steel surface was coated in different heat inputs with (wt.-%) 50FeCrC-20FeW-30FeB powder mixture by using plasma transferred arc (PTA) welding method. The microstructure of the coated samples were investigated by using optical microscope (OM), scanning electron microscope (SEM), X-ray diffraction (XRD) and energy dispersive X-ray (EDS). The hardness was measured with micro hardness test device. The dry sliding wear and friction coefficient properties were determined using a block-on-disk type wear test device. Wear tests were performed at 19.62 N, 39.24 N, 58.86 N load and the sliding distance of 900 m. The results were shown that different microstructures formed due to the heat input change. The highest average micro hardness value was measured at 1217 HV on sample coated with low heat input. It was determined that the wear resistance decreased with increasing heat input.
Gürgenç, Turan
2018-01-01
In this study, AISI 1020 steel surface was coated in different heat inputs with (wt.-%) 50FeCrC-20FeW-30FeB powder mixture by using plasma transferred arc (PTA) welding method. The microstructure of the coated samples were investigated by using optical microscope (OM), scanning electron microscope (SEM), X-ray diffraction (XRD) and energy dispersive X-ray (EDS). The hardness was measured with micro hardness test device. The dry sliding wear and friction coefficient properties were determined using a block-on-disk type wear test device. Wear tests were performed at 19.62 N, 39.24 N, 58.86 N load and the sliding distance of 900 m. The results were shown that different microstructures formed due to the heat input change. The highest average micro hardness value was measured at 1217 HV on sample coated with low heat input. It was determined that the wear resistance decreased with increasing heat input. PMID:29324875
Effect of sterilization irradiation on friction and wear of ultrahigh-molecular-weight polyethylene
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.; Hady, W. F.; Crugnola, A.
1979-01-01
The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against 316L stainless steel in dry air at 23 C was determined. A pin-on-disk apparatus was used. Experimental conditions included a 1-kilogram load, a 0.061- to 0.27-meter-per-second sliding velocity, and a 32000- to 578000-meter sliding distance. Although sterilization doses of 2.5 and 5.0 megarads greatly altered the average molecular weight and the molecular weight distribution, the friction and wear properties of the polymer were not significantly changed.
Dry sliding wear behavior of TIG welding clad WC composite coatings
NASA Astrophysics Data System (ADS)
Buytoz, Soner; Ulutan, Mustafa; Yildirim, M. Mustafa
2005-12-01
In this study, melted tungsten carbide powders on the surface of AISI 4340 steel was applied by using tungsten inert gas (TIG) method. It was observed that it has been solidified in different microstructures depending on the production parameters. As a result of microstructure examinations, in the surface modified layers an eutectic and dendrite solidification was observed together with WC, W 2C phases. In the layer produced, the hardness values varied between 950 and 1200 HV. The minimum mass loss was observed in the sample, which was treated in 1.209 mm/s production rate, 0.5 g/s powder feed rate and 13.9 kJ/cm heat input.
Cerium Addition Improved the Dry Sliding Wear Resistance of Surface Welding AZ91 Alloy
Zhao, Zhihao; Zhu, Qingfeng; Wang, Gaosong; Tao, Kai
2018-01-01
In this study, the effects of cerium (Ce) addition on the friction and wear properties of surface welding AZ91 magnesium alloys were evaluated by pin-on-disk dry sliding friction and wear tests at normal temperature. The results show that both the friction coefficient and wear rate of surfacing magnesium alloys decreased with the decrease in load and increase in sliding speed. The surfacing AZ91 alloy with 1.5% Ce had the lowest friction coefficient and wear rate. The alloy without Ce had the worst wear resistance, mainly because it contained a lot of irregularly shaped and coarse β-Mg17Al12 phases. During friction, the β phase readily caused stress concentration and thus formed cracks at the interface between β phase and α-Mg matrix. The addition of Ce reduced the size and amount of Mg17Al12, while generating Al4Ce phase with a higher thermal stability. The Al-Ce phase could hinder the grain-boundary sliding and migration and reduced the degree of plastic deformation of subsurface metal. Scanning electron microscopy observation showed that the surfacing AZ91 alloy with 1.5% Ce had a total of four types of wear mechanism: abrasion, oxidation, and severe plastic deformation were the primary mechanisms; delamination was the secondary mechanism. PMID:29415492
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher
2010-01-01
An intermetallic nickel-titanium alloy, 60NiTi (60 wt% Ni, 40 wt% Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high Ti content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of Ti and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of Ti alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is presented.
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher
2010-01-01
An intermetallic nickel-titanium alloy, 60NiTi (60wt%Ni, 40wt%Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high titanium content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of titanium and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of titanium alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is studied.
NASA Astrophysics Data System (ADS)
Nakajima, Daiki; Kikuchi, Tatsuya; Natsui, Shungo; Suzuki, Ryosuke O.
2016-12-01
A superhydrophilic aluminum surface covered by numerous alumina nanofibers was fabricated via pyrophosphoric acid anodizing. High-density anodic alumina nanofibers grow on the bottom of a honeycomb oxide via anodizing in concentrated pyrophosphoric acid. The water contact angle on the nanofiber-covered aluminum surface decreased with time after a 4 μL droplet was placed on the surface, and a superhydrophilic behavior with a contact angle measuring 2.2° was observed within 2 s; this contact angle is considerably lower than those observed for electropolished and porous alumina-covered aluminum surfaces. There was no dependence of the superhydrophilicity on the density of alumina nanofibers fabricated via different constant voltage anodizing conditions. The superhydrophilic property of the surface covered by anodic alumina nanofibers was maintained during an exposure test for 359 h. The quick-drying and snow-sliding behaviors of the superhydrophilic aluminum covered with anodic alumina nanofibers were demonstrated.
Effect of in-situ TiC particulate on the wear resistance of spray-deposited 7075 Al matrix composite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Feng; Liu Huimin; Yang Bin
2005-05-15
TiC reinforced 7075 Al matrix composites have been fabricated by a melt in-situ reaction spray deposition. The microstructures of spray-deposited alloys were studied using scanning electron microscopy (SEM) and X-ray diffraction (XRD). The dry sliding wear behavior of the alloys was investigated using a pin-on-disc machine under four loads, namely 8.9, 17.8, 26.7 and 35.6 N. It has been found that the wear behavior of the alloys was dependent on the TiC content in the microstructure and the applied load. At a lower load (8.9 N), with increasing TiC content, the wear rate of the alloy was decreased. At amore » higher loads (26.7, 35.6 N), a spray-deposited 7075 Al alloy exhibited superior wear resistance to the 7075/TiC composites.« less
Tribological Behavior of IN718 Superalloy Coating Fabricated by Laser Additive Manufacturing
NASA Astrophysics Data System (ADS)
Zhang, Yaocheng; Pan, Qiyong; Yang, Li; Li, Ruifeng; Dai, Jun
2017-12-01
The tribological behavior of laser manufactured IN718 superalloy coating are investigated with different applied loads, sliding speeds and lubricating mediums. The wear resistance of laser manufactured IN718 coating is increased by heat treatment due to higher microhardness and homogeneous brittle phase distribution. The principal factors for the wear rate are applied load and lubricating medium. The worn surface of laser manufactured IN718 coating consists of the grooves, crack, wear debris and material delamination generated by the fatigue wear associated with adhesive wear and abrasive wear. The friction coefficients are influenced by the tribological noise decrescence by the tribo-oxidant and the liquid lubricant. The real contact temperature between coating sample and frictional counterpart is higher than the solid-solution temperature of IN718 superalloy, and the effect of surface contact temperature on the orientational microstructure and wear resistance for dry friction and wet friction process is indistinct.
Cell adhesion on nanotextured slippery superhydrophobic substrates.
Di Mundo, Rosa; Nardulli, Marina; Milella, Antonella; Favia, Pietro; d'Agostino, Riccardo; Gristina, Roberto
2011-04-19
In this work, the response of Saos2 cells to polymeric surfaces with different roughness/density of nanometric dots produced by a tailored plasma-etching process has been studied. Topographical features have been evaluated by atomic force microscopy, while wetting behavior, in terms of water-surface adhesion energy, has been evaluated by measurements of drop sliding angle. Saos2 cytocompatibility has been investigated by scanning electron microscopy, fluorescent microscopy, and optical microscopy. The similarity in outer chemical composition has allowed isolation of the impact of the topographical features on cellular behavior. The results indicate that Saos2 cells respond differently to surfaces with different nanoscale topographical features, clearly showing a certain inhibition in cell adhesion when the nanoscale is particularly small. This effect appears to be attenuated in surfaces with relatively bigger nanofeatures, though these express a more pronounced slippery/dry wetting character. © 2011 American Chemical Society
Stick-slip nanofriction in cold-ion traps
NASA Astrophysics Data System (ADS)
Mandelli, Davide; Vanossi, Andrea; Tosatti, Erio
2013-03-01
Trapped cold ions are known to form linear or planar zigzag chains, helices or clusters depending on trapping conditions. They may be forced to slide over a laser induced corrugated potential, a mimick of sliding friction. We present MD simulations of an incommensurate 101 ions chain sliding subject to an external electric field. As expected with increasing corrugation, we observe the transition from a smooth-sliding, highly lubric regime to a strongly dissipative stick-slip regime. Owing to inhomogeneity the dynamics shows features reminiscent of macroscopic frictional behaviors. While the chain extremities are pinned, the incommensurate central part is initially free to slide. The onset of global sliding is preceded by precursor events consisting of partial slips of chain portions further from the center. We also look for frictional anomalies expected for the chain sliding across the linear-zigzag structural phase transition. Although the chain is too short for a proper critical behavior, the sliding friction displays a frank rise near the transition, due to opening of a new dissipative channel via excitations of transverse modes. Research partly sponsored by Sinergia Project CRSII2 136287/1.
Bedrock erosion by sliding wear in channelized granular flow
NASA Astrophysics Data System (ADS)
Hung, C. Y.; Stark, C. P.; Capart, H.; Smith, B.; Maia, H. T.; Li, L.; Reitz, M. D.
2014-12-01
Boundary forces generated by debris flows can be powerful enough to erode bedrock and cause considerable damage to infrastructure during runout. Bedrock wear can be separated into impact and sliding wear processes. Here we focus on sliding wear. We have conducted experiments with a 40-cm-diameter grainflow-generating rotating drum designed to simulate dry channelized debris flows. To generate sliding erosion, we placed a 20-cm-diameter bedrock plate axially on the back wall of the drum. The rotating drum was half filled with 2.3-mm-diameter grains, which formed a thin grain-avalanching layer with peak flow speed and depth close to the drum axis. The whole experimental apparatus was placed on a 100g-ton geotechnical centrifuge and, in order to scale up the stress level, spun to a range of effective gravity levels. Rates and patterns of erosion of the bedrock plate were mapped after each experiment using 3d micro-photogrammetry. High-speed video and particle tracking were employed to measure granular flow dynamics. The resulting data for granular velocities and flow geometry were used to estimate impulse exchanges and forces on the bedrock plate. To address some of the complexities of granular flow under variable gravity levels, we developed a continuum model framed around a GDR MiDi rheology. This model allowed us to scale up boundary forcing while maintaining the same granular flow regime, and helped us to understand important aspects of the flow dynamics including e.g. fluxes of momentum and kinetic energy. In order to understand the detailed processes of boundary forcing, we performed numerical simulations with a new contact dynamics model. This model confirmed key aspects of our continuum model and provided information on second-order behavior such as fluctuations in the forces acting on the wall. By combining these measurements and theoretical analyses, we have developed and calibrated a constitutive model for sliding wear that is a threshold function of granular velocity and stress.
Synergistic Interactions of Neuroprotective and Neurotrophic Factors Against Sleep Deprivation
2017-03-30
Following this approach, the animals are placed on the small platform and when they enter into a deep sleep or rapid eye movement (REM), the...incubated in a dark chamber overnight at 37 ᵒC. The dry slides were cleared by immersion in xylene for 12 Distribution A: Approved for public release...fluorescent plastic mounting media. These samples were allowed to dry in the dark overnight. After drying , the tissue was then examined using an
NASA Astrophysics Data System (ADS)
Jia, Yulong; Wan, Hongqi; Chen, Lei; Zhou, Huidi; Chen, Jianmin
2016-09-01
Influence of nanometer lanthanum fluoride (nano-LaF3) on the tribological behaviors of polytetrafluoroethylene (PTFE) bonded solid lubricating coatings were investigated using a ring-on-block friction-wear tester under dry friction and RP-3 jet fuel lubrication conditions. The worn surfaces and transfer films formed on the counterpart steel rings were observed by scanning electron microscope (SEM) and optical microscope (OM), respectively. The microstructures of the nano-LaF3 modified coatings and the distribution states of nano-LaF3 were studied by field-emission scanning electron microscope (FESEM) and transmission electron microscopy (TEM), respectively. The results show that incorporation of nano-LaF3 improves the microhardness and the friction-reduced and anti-wear abilities of PTFE bonded solid lubricating coatings. The wear life of the modified coating is about 6 times longer than that of the coating without nano-LaF3 filler at a relatively low applied load (200 N) and rotary speed (1000 rev/min) under dry friction condition. The friction coefficient and wear life of the modified coating decrease with increase of applied load under dry friction, but the friction coefficient has hardly any variation and wear life decreases under RP-3 jet fuel lubrication condition. In addition, the friction coefficient of the modified coating reduces with the rotary speed increasing under dry sliding but has little change under RP-3 lubrication, the wear life increases firstly and then decreases. The results indicated that the wear failure mechanism is dominated by applied load, which plays an important role in guidance of application of nano-LaF3 modified PTFE bonded coating under different working environment.
Impact wear behavior of human tooth enamel under simulated chewing conditions.
Zheng, Jing; Zeng, Yangyang; Wen, Jian; Zheng, Liang; Zhou, Zhongrong
2016-09-01
Previous studies mostly focused on the sliding wear behavior of human teeth, and little effort has been made so far to study the impact wear of human teeth. The objective of this study was to investigate the impact wear process and mechanism of human tooth enamel and the influence of water content within enamel. In this paper, the impact wear behaviors of fresh and dried human tooth enamel against SiC ceramic have been investigated using a specially designed impact test machine. Tests lasting up to 5×10(3), 5×10(4), 2.5×10(5), 5.5×10(5), 8×10(5) and 1×10(6) cycles were conducted, respectively. Results showed that for the fresh enamel, the surface damage was dominated by plastic deformation at the early stage of impact wear. Iridescent rings appeared around the impact mark as a result of the accumulation and spread of plastic deformation. As the impact wear progressed, delamination occurred on the surface of enamel, and thus the iridescent rings gradually disappeared. Wear loss increased rapidly with the increase of impact cycles. When a wear particle layer was formed on the enamel surface, the wear rate decreased. It was found that the surface hardness of enamel increased with the impact cycles, and no cracks appeared on the cross section of wear scar. Compared with the fresh enamel, the fracture toughness of dried enamel decreased, and thus there were microcracks appearing on the cross section of wear scar. More obvious delamination occurred on the worn surface of dried enamel, and no iridescent rings were observed. The wear loss of dried enamel was higher than that of fresh enamel. In summary, the impact wear behavior of sound human tooth enamel was metal-like to some degree, and no subsurface cracking occurred. The water content within enamel could increase its fracture toughness and protect the surface from impact wear. The wear mechanism of human tooth enamel is determined by its microstructure. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Proctor, B. P.; Lockner, D. A.; Lowenstern, J. B.; Beeler, N. M.
2017-10-01
Coseismic frictional melting and the production of quenched glass called pseudotachylyte is a recurring process during earthquakes. To investigate how glassy materials affect the postseismic strength and stability of faults, obsidian gouges were sheared under dry and wet conditions from 200°C to 300°C at 150 MPa effective normal stress. Dry glass exhibited a brittle rheology at all conditions tested, exhibiting friction values and microstructures consistent with siliciclastic materials. Likewise, wet glass at 200°C exhibited a brittle rheology. In contrast, wet gouges at 300°C transitioned from brittle sliding to linear-viscous (Newtonian) flow at strain rates <3 × 10-4 s-1, indicating melt-like behavior. The viscosity ranged from 2 × 1011 to 7.8 × 1011 Pa-s. Microstructures show that viscous gouges were fully welded with rod-shaped microlites rotated into the flow direction. Fourier transform infrared spectroscopy along with electron backscatter imaging demonstrate that hydration of the glass by diffusion of pore water was the dominant process reducing the viscosity and promoting viscous flow. As much as 5 wt % water diffused into the glass. These results may provide insight into postseismic-slip behaviors and challenge some interpretations of fault kinematics based on studies assuming that pseudotachylyte formation and flow is solely coseismic.
Contact Geometry and Distribution of Plasma Generated in the Vicinity of Sliding Contact
NASA Astrophysics Data System (ADS)
Nakayama, Keiji
2007-09-01
The effect of the geometry of the smaller sliding partner on plasma (triboplasma) generation has been investigated as a function of the tip radius of a diamond pin, which slides against a single crystal sapphire disk under atmospheric dry air pressure. It was found that the diameter and the total intensity of the circular triboplasma increase parabolically with an increase in the tip radius of the pin under constant normal force and sliding velocity. The plasma is most intense at the crossing point of the plasma ring and the frictional track in the plasma circle. The gap distance at the crossing point is independent of the tip radius. The ring diameter increases with an increase in the tip radius, keeping the gap distance constant and obeying Paschen’s law of gas discharge.
The dryout region in frictionally heated sliding contacts
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Braun, J.; Arp, V.; Giarratano, P. J.
1982-01-01
Some conditions under which boiling and two-phase flow can occur in or near a wet sliding contact are determined and illustrated. The experimental apparatus consisted of a tool pressed against an instrumented slider plate and motion picture sequences at 4000 frames/sec. The temperature and photographic data demonstrated surface conditions of boiling, drying, trapped gas evolution (solutions), and volatility of fluid mixture components. The theoretical modeling and analysis are in reasonable agreement with experimental data.
Impact of formulation and saliva on acid milk gel friction behavior.
Joyner Melito, Helen S; Pernell, Chris W; Daubert, Christopher R
2014-05-01
Rheological analysis is commonly used to evaluate mechanical properties in studies of food behavior. However, rheological analysis is often insufficient to describe food texture as evaluated by descriptive sensory analysis. Additionally, traditional rheometry does not account for changes in food behavior as a function of saliva incorporation into the food during mastication. The objectives of this study were to evaluate friction behavior of acid milk gels with and without the addition of saliva, and to determine relationships between frictional behaviors and mechanical and sensory behaviors. Acid milk gels were prepared with 12.5% total solids comprising nonfat dry milk, whey protein isolate, waxy maize starch, and gelatin in different ratios. The addition of starch was found to have significant impact on acid milk gel frictional behavior. Addition of saliva resulted in a change in frictional behavior over the entire sliding speed range measured. Correlations were found between rheological, tribological, and sensory behavior, suggesting that an underlying mechanism may impact both viscosity and friction behavior. Additional study is needed to further explore the links between food structure, rheology, tribology, and sensory texture. Application of tribology in food science allows measurement of friction behavior of foods. Matching both rheological and tribological behavior is important to creating reduced-fat or reduced-sugar products with similar mouthfeel to the original product. © 2014 Institute of Food Technologists®
Routine Digital Pathology Workflow: The Catania Experience
Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana
2017-01-01
Introduction: Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. Methods: All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Results: Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Conclusion: Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory. PMID:29416914
Routine Digital Pathology Workflow: The Catania Experience.
Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana
2017-01-01
Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory.
DEM Modeling of a Flexible Barrier Impacted by a Dry Granular Flow
NASA Astrophysics Data System (ADS)
Albaba, Adel; Lambert, Stéphane; Kneib, François; Chareyre, Bruno; Nicot, François
2017-11-01
Flexible barriers are widely used as protection structures against natural hazards in mountainous regions, in particular for containing granular materials such as debris flows, snow avalanches and rock slides. This article presents a discrete element method-based model developed in the aim of investigating the response of flexible barriers in such contexts. It allows for accounting for the peculiar mechanical and geometrical characteristics of both the granular flow and the barrier in a same framework, and with limited assumptions. The model, developed with YADE software, is described in detail, as well as its calibration. In particular, cables are modeled as continuous bodies. Besides, it naturally considers the sliding of rings along supporting cables. The model is then applied for a generic flexible barrier to demonstrate its capacities in accounting for the behavior of different components. A detailed analysis of the forces in the different components showed that energy dissipators (ED) had limited influence on total force applied to the barrier and retaining capacity, but greatly influenced the load transmission within the barrier and the force in anchors. A sensitivity analysis showed that the barrier's response significantly changes according to the choice of ED activation force and incoming flow conditions.
Sun, Wei; Xuan, Xihua; Li, Liang; An, Jian
2018-01-01
Dry friction and wear tests were performed on as-cast Mg97Zn1Y2 alloy using a pin-on-disc configuration. Coefficients of friction and wear rates were measured as a function of applied load at sliding speeds of 0.2, 0.8 and 3.0 m/s. The wear mechanisms were identified in the mild and severe wear regimes by means of morphological observation and composition analysis of worn surfaces using scanning electron microscope (SEM) and energy dispersive X-ray spectrometer (EDS). Analyses of microstructure and hardness changes in subsurfaces verified the microstructure transformation from the deformed to the dynamically recrystallized, and properties changed from the strain hardening to dynamic crystallization (DRX) softening before and after the mild–severe wear transition. The mild–severe wear transition can be determined by a proposed contact surface DRX temperature criterion, from which the critical DRX temperatures at different sliding speeds are calculated using DRX dynamics; hence transition loads can also be calculated using a transition load model. The calculated transition loads are in good agreement with the measured ones, demonstrating the validity and applicability of the contact surface DRX temperature criterion. PMID:29584692
Quantitative measure of the variation in fault rheology due to fluid-rock interactions
Blanpied, M.L.; Marone, C.J.; Lockner, D.A.; Byerlee, J.D.; King, D.P.
1998-01-01
We analyze friction data from two published suites of laboratory tests on granite in order to explore and quantify the effects of temperature (T) and pore water pressure (Pp) on the sliding behavior of faults. Rate-stepping sliding tests were performed on laboratory faults in granite containing "gouge" (granite powder), both dry at 23?? to 845??C [Lockner et al., 1986], and wet (Pp = 100 MPa) at 23?? to 600??C [Blanpied et al., 1991, 1995]. Imposed slip velocities (V) ranged from 0.01 to 5.5 ??m/s, and effective normal stresses were near 400 MPa. For dried granite at all temperatures, and wet granite below -300??C, the coefficient of friction (??) shows low sensitivity to V, T, and Pp. For wet granite above -350??, ?? drops rapidly with increasing T and shows a strong, positive rate dependence and protracted strength transients following steps in V, presumably reflecting the activity of a water-aided deformation process. By inverting strength data from velocity stepping tests we determined values for parameters in three formulations of a rate- and state-dependent constitutive law. One or two state variables were used to represent slip history effects. Each velocity step yielded an independent set of values for the nominal friction level, five constitutive parameters (transient parameters a, b1, and b2 and characteristic displacements Dcl and Dc2), and the velocity dependence of steady state friction ?????ss/??? In V = a-b1-b2. Below 250??, data from dry and most wet tests are adequately modeled by using the "slip law" [Ruina, 1983] and one state variable (a = 0.003 to 0.018, b = 0.001 to +0.018, Dc ??? 1 to 20 ??m). Dried tests above 250?? can also be fitted with one state variable. In contrast, wet tests above 350?? require higher direct rate dependence (a = 0.03 to 0.12), plus a second state variable with large, negative amplitude (b2 = -0.03 to -0.14) and large characteristic displacement (Dc2 = 300 to >4000 ??m). Thus the parameters a, b1, and b2 for wet granite show a pronounced change in their temperature dependence in the range 270?? to 350??C, which may reflect a change in underlying deformation mechanism. We quantify the trends in parameter values from 25?? to 600??C by piecewise linear regressions, which provide a straightforward means to incorporate the full constitutive response of granite into numerical models of fault slip. The modeling results suggest that the succeptibility for unstable (stick-slip) sliding is maximized between 90?? and 360??C, in agreement with laboratory observations and consistent with the depth range of earthquakes on mature faults in the continental crust.
Amiriyan, Mahdi; Blais, Carl; Savoie, Sylvio; Schulz, Robert; Gariépy, Mario; Alamdari, Houshang
2016-01-01
This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. This study reveals the effect of TiB2 particles on the mechanical and tribological properties of Fe3Al-TiB2 composite coatings against an alumina counterpart. The feedstock was produced by milling Fe3Al and TiB2 powders in a high energy ball mill. The high-velocity oxy-fuel (HVOF) technique was used to deposit the feedstock powder on a steel substrate. The effect of TiB2 addition on mechanical properties and dry sliding wear rates of the coatings at sliding speeds ranging from 0.04 to 0.8 m·s−1 and loads of 3, 5 and 7 N was studied. Coatings made from unreinforced Fe3Al exhibited a relatively high wear rate. The Vickers hardness, elastic modulus and wear resistance of the coatings increased with increasing TiB2 content in the Fe3Al matrix. The wear mechanisms strongly depended on the sliding speed and the presence of TiB2 particles but were less dependent on the applied load. PMID:28787917
Byerlee, J.D.
1970-01-01
Physical mechanisms that have been proposed to explain the occurrence of stick-slip motion during frictional sliding have been examined in the light of results obtained from experiments with rocks and brittle minerals. An instability caused by sudden brittle fracture of locked regions on surfaces in contact is the most likely explanation for stick-slip during dry frictional sliding of brittle rocks at room temperature. Areas requiring further study and the uncertainties in applying the results of laboratory experiments to earthquake studies are emphasized. ?? 1970.
Zhang, Chaoyang; Cao, Xia; Xiang, Bin
2012-04-01
We simulated the shear slide behavior of typical mixed HMX-olefin systems and the effect of thickness of olefin layers (4-22 Å) on the behavior at a molecular level by considering two cases: bulk shear and interfacial shear. The results show that: (1) the addition of olefin into HMX can reduce greatly the shear sliding barriers relative to the pure HMX in the two cases, suggesting that the desensitizing mechanism of olefin is controlled dominantly by its good lubricating property; (2) the change of interaction energy in both systoles of shear slide is strongly dominated by van der Waals interaction; and (3) the thickness of olefin layers in the mixed explosives can influence its desensitizing efficiency. That is, the excessive thinness of olefin layers in the mixed explosive systems, for example, several angstroms, can lead to very high sliding barriers.
NASA Astrophysics Data System (ADS)
Su, Wei; Zhou, Ti; Zhang, Peng; Zhou, Hong; Li, Hui
2018-01-01
Some biological surfaces were proved to have excellent anti-wear performance. Being inspired, Nd:YAG pulsed laser was used to create striated biomimetic laser hardening tracks on medium carbon steel samples. Dry sliding wear tests biomimetic samples were performed to investigate specific influence of distribution of laser hardening tracks on sliding wear resistance of biomimetic samples. After comparing wear weight loss of biomimetic samples, quenched sample and untreated sample, it can be suggested that the sample covered with dense laser tracks (3.5 mm spacing) has lower wear weight loss than the one covered with sparse laser tracks (4.5 mm spacing); samples distributed with only dense laser tracks or sparse laser tracks (even distribution) were proved to have better wear resistance than samples distributed with both dense and sparse tracks (uneven distribution). Wear mechanisms indicate that laser track and exposed substrate of biomimetic sample can be regarded as hard zone and soft zone respectively. Inconsecutive striated hard regions, on the one hand, can disperse load into small branches, on the other hand, will hinder sliding abrasives during wear. Soft regions with small range are beneficial in consuming mechanical energy and storing lubricative oxides, however, soft zone with large width (>0.5 mm) will be harmful to abrasion resistance of biomimetic sample because damages and material loss are more obvious on surface of soft phase. As for the reason why samples with even distributed bionic laser tracks have better wear resistance, it can be explained by the fact that even distributed laser hardening tracks can inhibit severe worn of local regions, thus sliding process can be more stable and wear extent can be alleviated as well.
Investigation on wear and corrosion behavior of equal channel angular pressed aluminium 2014 alloy
NASA Astrophysics Data System (ADS)
Divya, S. P.; Yoganandan, G.; Balaraju, J. N.; Srinivasan, S. A.; Nagaraj, M.; Ravisankar, B.
2018-02-01
Aluminium 2014 alloy solutionized at 495°C, aged at 195°C was subjected to Equal Channel Angular Pressing (ECAP). Dry sliding wear tests were conducted using pin on disc tribometer system under nominal loads of 10N and 30N with constant speed 2m/s for 2000m in order to investigate their wear behavior after ECAP. The Co-efficient of friction and loss in volume were decreased after ECAP. The dominant wear mechanism observed was adhesion, delamination in addition to these wear mechanisms, oxidation and transfer of Fe from the counter surface to the Al 2014 pin were observed at higher loading condition. The corrosion behavior was evaluated by potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) in 3.5% NaCl solution. The results obtained from PDP showed higher corrosion potential and lower corrosion density after ECAP than base. Electrochemical impedance spectroscopy (EIS) showed higher charge transfer resistance after ECAP. Surface morphology showed decreased pit size and increased oxygen content in ECAP sample than base after PDP.
Sliding Wear Characteristics and Corrosion Behaviour of Selective Laser Melted 316L Stainless Steel
NASA Astrophysics Data System (ADS)
Sun, Y.; Moroz, A.; Alrbaey, K.
2014-02-01
Stainless steel is one of the most popular materials used for selective laser melting (SLM) processing to produce nearly fully dense components from 3D CAD models. The tribological and corrosion properties of stainless steel components are important in many engineering applications. In this work, the wear behaviour of SLM 316L stainless steel was investigated under dry sliding conditions, and the corrosion properties were measured electrochemically in a chloride containing solution. The results show that as compared to the standard bulk 316L steel, the SLM 316L steel exhibits deteriorated dry sliding wear resistance. The wear rate of SLM steel is dependent on the vol.% porosity in the steel and by obtaining full density it is possible achieve wear resistance similar to that of the standard bulk 316L steel. In the tested chloride containing solution, the general corrosion behaviour of the SLM steel is similar to that of the standard bulk 316L steel, but the SLM steel suffers from a reduced breakdown potential and is more susceptible to pitting corrosion. Efforts have been made to correlate the obtained results with porosity in the SLM steel.
NASA Astrophysics Data System (ADS)
Woods, David Keith
The purpose of this study was to analyze the resistance to sliding of coated rectangular fiber reinforced composite archwires using various brackets systems and second-order bracket angulations. Resistance to sliding was investigated for eight bracket systems: six self-ligating brackets (four passive and two passive-active) and two conventional brackets. A rectangular fiber reinforced composite archwire of 0.019 x 0.025-in dimension from BiomersRTM SimpliClear was drawn through a three-bracket model system at ten millimeters per minute for 2.5 millimeters. For each bracket, the resistance to sliding was measured at four bracket angulations (0°, 2.5°, 5°, and 10°) in a dry state at room temperature. The fiber reinforced composite archwire produced the lowest sliding resistance with the passive self-ligating bracket system (Damon DQ) at each bracket angulation tested. Overall, self-ligating bracket systems generated lower sliding resistance than conventionally ligated systems, and one passive/active self-ligating bracket system (In-Ovation-R). There was a significant increase in resistance to sliding as bracket angulation increased for all bracket systems tested. Microscopic analysis revealed increased perforation of the archwire coating material as bracket angulations were increased. Our findings show that the rectangular fiber reinforced composite archwire may be acceptable for sliding mechanics during the intermediate stages of orthodontic tooth movement, however more long-term studies are needed.
Fate study of water-borne gram positive vegetative bacterial cells with Raman microscopy
NASA Astrophysics Data System (ADS)
Guicheteau, Jason; Tripathi, Ashish; Minter, Jennifer; Wilcox, Phillip; Christesen, Steven
2010-04-01
We present an initial bacterial fate study of Gram positive vegetative cells suspended in water and stored at ambient room temperature via Raman spectroscopy monitoring. Two types of cells were considered for this study: vegetative cells of Bacillus cereus, Bacillus thuringiensis which contain the polyhydroxybutyric acid (PHBA) as an energy storage compound and Bacillus subtlilis cells which do not. The cells were cultured specifically for this project. Immediately following the culturing phase, the bacteria were extracted, cleaned and at the onset of the study were suspended in de-ionized water and stored at room temperature. Aliquots of suspensions were deposited onto aluminum slides at different times and allowed to dry for Raman analysis. Spectra from multiple regions of each dried spot and each deposit time were acquired along with the bright-field and fluorescence images. Results were examined to investigate the effect of suspension time on the spectral signatures as well as the fate behavior of the three types of cells investigated. The cells were monitored daily for over a 14 period during which time the onset of starvation induced sporulation was observed.
Mercan, Ezgi; Aksoy, Selim; Shapiro, Linda G; Weaver, Donald L; Brunyé, Tad T; Elmore, Joann G
2016-08-01
Whole slide digital imaging technology enables researchers to study pathologists' interpretive behavior as they view digital slides and gain new understanding of the diagnostic medical decision-making process. In this study, we propose a simple yet important analysis to extract diagnostically relevant regions of interest (ROIs) from tracking records using only pathologists' actions as they viewed biopsy specimens in the whole slide digital imaging format (zooming, panning, and fixating). We use these extracted regions in a visual bag-of-words model based on color and texture features to predict diagnostically relevant ROIs on whole slide images. Using a logistic regression classifier in a cross-validation setting on 240 digital breast biopsy slides and viewport tracking logs of three expert pathologists, we produce probability maps that show 74 % overlap with the actual regions at which pathologists looked. We compare different bag-of-words models by changing dictionary size, visual word definition (patches vs. superpixels), and training data (automatically extracted ROIs vs. manually marked ROIs). This study is a first step in understanding the scanning behaviors of pathologists and the underlying reasons for diagnostic errors.
NASA Astrophysics Data System (ADS)
Song, Hao-Jie; Li, Na; Yang, Jin; Min, Chun-Ying; Zhang, Zhao-zhu
2013-02-01
The composite films of poly (ether ether ketone) (PEEK) filled with different proportions of graphene oxide (GO) nanosheets were prepared by the cast method. The tribological behaviors of the composite films under boundary lubrication (water and liquid paraffin oil lubrication) were investigated and compared with that under dry sliding on an UMT-2 friction and wear machine, by running a steel sphere against the composite films. The results were as follows: GO nanosheets as the filler greatly improve the wear resistance of PEEK under boundary lubrication, though the composites show a different dependence of wear resistance on the filler content. Scanning electron microscopy and optical microscopy performed to analyze the wear scar surfaces after friction confirmed that the outstanding lubrication performance of GO could be attributed to their small size and extremely thin laminated structure, which allow the GO to easily enter the contact area, thereby preventing the rough surfaces from coming into direct contact.
Friction behavior of network-structured CNT coating on pure titanium plate
NASA Astrophysics Data System (ADS)
Umeda, Junko; Fugetsu, Bunshi; Nishida, Erika; Miyaji, Hirofumi; Kondoh, Katsuyoshi
2015-12-01
Friction behavior of the network-structured CNTs coated pure Ti plate was evaluated by ball-on-disk wear test using SUS304 ball specimen under dry condition. The friction coefficient was significantly low and stable compared to the as-received Ti plate with no coating film. CNTs coating film had two important roles; self-lubrication and bearing effects to reduce the friction coefficient and carbon solid-solution hardening to improve the abrasive wear property of Ti plate. The annealing treatment at higher temperature (1123 K) was more effective to reduce the friction coefficient than that at lower temperature (973 K) because the Ti plate surface was uniformly covered with CNTs film even after sliding wear test. This is due to TiC interlayer formation via a reaction between Ti plate and carbon elements originated from CNTs during annealing. As a result, a strong interface bonding between CNTs film and Ti plate surface was obtained by higher temperature annealing treatment, and obstructed the detachment of CNTs film during wear test.
Gram staining with an automatic machine.
Felek, S; Arslan, A
1999-01-01
This study was undertaken to develop a new Gram-staining machine controlled by a micro-controller and to investigate the quality of slides that were stained in the machine. The machine was designed and produced by the authors. It uses standard 220 V AC. Staining, washing, and drying periods are controlled by a timer built in the micro-controller. A software was made that contains a certain algorithm and time intervals for the staining mode. One-hundred and forty smears were prepared from Escherichia coli, Staphylococcus aureus, Neisseria sp., blood culture, trypticase soy broth, direct pus and sputum smears for comparison studies. Half of the slides in each group were stained with the machine, the other half by hand and then examined by four different microbiologists. Machine-stained slides had a higher clarity and less debris than the hand-stained slides (p < 0.05). In hand-stained slides, some Gram-positive organisms showed poor Gram-positive staining features (p < 0.05). In conclusion, we suggest that Gram staining with the automatic machine increases the staining quality and helps to decrease the work load in a busy diagnostic laboratory.
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Street, Kenneth W., Jr.; Andraws, Rodney; Jacques, David; VanderWal, Randy L.; Sayir, Ali
2005-01-01
To evaluate recently developed aligned multiwalled carbon nanotubes (MWNTs) and dispersed MWNTs for solid lubrication applications, unidirectional sliding friction experiments were conducted with 440 C stainless steel balls and hemispherical alumina-yttria stabilized zirconia pins in sliding contact with the MWNTs deposited on quartz disks in air and in vacuum. The results indicate that MWNTs have superior solid lubrication friction properties and endurance lives in air and vacuum under dry conditions. The coefficient of friction of the dispersed MWNTs is close to 0.05 and 0.009 in air and in vacuum, respectively, showing good dry lubricating ability. The wear life of MWNTs exceeds 1 million passes in both air and vacuum showing good durability. In general, the low coefficient of friction can be attributed to the combination of the transferred, agglomerated patches of MWNTs on the counterpart ball or pin surfaces and the presence of tubular MWNTs at interfaces.
Cyclic Fiber Push-In Test Monitors Evolution of Interfacial Behavior in Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I.
1998-01-01
SiC fiber-reinforced ceramic matrix composites are being developed for high-temperature advanced jet engine applications. Obtaining a strong, tough composite material depends critically on optimizing the mechanical coupling between the reinforcing fibers and the surrounding matrix material. This has usually been accomplished by applying a thin C or BN coating onto the surface of the reinforcing fibers. The performance of these fiber coatings, however, may degrade under cyclic loading conditions or exposure to different environments. Degradation of the coating-controlled interfacial behavior will strongly affect the useful service lifetime of the composite material. Cyclic fiber push-in testing was applied to monitor the evolution of fiber sliding behavior in both C- and BN-coated small-diameter (15-mm) SiC-fiber-reinforced ceramic matrix composites. The cyclic fiber push-in tests were performed using a desktop fiber push-out apparatus. At the beginning of each test, the fiber to be tested was aligned underneath a 10- mm-diameter diamond punch; then, the applied load was cycled between selected maximum and minimum loads. From the measured response, the fiber sliding distance and frictional sliding stresses were determined for each cycle. Tests were performed in both room air and nitrogen. Cyclic fiber push-in tests of C-coated, SiC-fiber-reinforced SiC showed progressive increases in fiber sliding distances along with decreases in frictional sliding stresses for continued cycling in room air. This rapid degradation in interfacial response was not observed for cycling in nitrogen, indicating that moisture exposure had a large effect in immediately lowering the frictional sliding stresses of C-coated fibers. These results indicate that matrix cracks bridged by C-coated fibers will not be stable, but will rapidly grow in moisture-containing environments. In contrast, cyclic fiber push-in tests of both BN-coated, SiC-fiber-reinforced SiC and BNcoated, SiC-fiber-reinforced barium strontium aluminosilicate showed no significant changes in fiber sliding behavior with continued short-term cycling in either room air or nitrogen. Although the composites with BN-coated fibers showed stable short-term cycling behavior in both environments, long-term (several-week) exposure of debonded fibers to room air resulted in dramatically increased fiber sliding distances and decreased frictional sliding stresses. These results indicate that although matrix cracks bridged by BNcoated fibers will show short-term stability, such cracks will show substantial growth with long-term exposure to moisture-containing environments. Newly formulated BN coatings, with higher moisture resistance, will be tested in the near future.
NASA Astrophysics Data System (ADS)
Tian, Pengyi; Tao, Dashuai; Yin, Wei; Zhang, Xiangjun; Meng, Yonggang; Tian, Yu
2016-09-01
Comprehension of stick-slip motion is very important for understanding tribological principles. The transition from creep-dominated to inertia-dominated stick-slip as the increase of sliding velocity has been described by researchers. However, the associated micro-contact behavior during this transition has not been fully disclosed yet. In this study, we investigated the stick-slip behaviors of two polymethyl methacrylate blocks actively modulated from the creep-dominated to inertia-dominated dynamics through a non-uniform loading along the interface by slightly tilting the angle of the two blocks. Increasing the tilt angle increases the critical transition velocity from creep-dominated to inertia-dominated stick-slip behaviors. Results from finite element simulation disclosed that a positive tilt angle led to a higher normal stress and a higher temperature on blocks at the opposite side of the crack initiating edge, which enhanced the creep of asperities during sliding friction. Acoustic emission (AE) during the stick-slip has also been measured, which is closely related to the different rupture modes regulated by the distribution of the ratio of shear to normal stress along the sliding interface. This study provided a more comprehensive understanding of the effect of tilted non-uniform loading on the local stress ratio, the local temperature, and the stick-slip behaviors.
Tian, Pengyi; Tao, Dashuai; Yin, Wei; Zhang, Xiangjun; Meng, Yonggang; Tian, Yu
2016-09-19
Comprehension of stick-slip motion is very important for understanding tribological principles. The transition from creep-dominated to inertia-dominated stick-slip as the increase of sliding velocity has been described by researchers. However, the associated micro-contact behavior during this transition has not been fully disclosed yet. In this study, we investigated the stick-slip behaviors of two polymethyl methacrylate blocks actively modulated from the creep-dominated to inertia-dominated dynamics through a non-uniform loading along the interface by slightly tilting the angle of the two blocks. Increasing the tilt angle increases the critical transition velocity from creep-dominated to inertia-dominated stick-slip behaviors. Results from finite element simulation disclosed that a positive tilt angle led to a higher normal stress and a higher temperature on blocks at the opposite side of the crack initiating edge, which enhanced the creep of asperities during sliding friction. Acoustic emission (AE) during the stick-slip has also been measured, which is closely related to the different rupture modes regulated by the distribution of the ratio of shear to normal stress along the sliding interface. This study provided a more comprehensive understanding of the effect of tilted non-uniform loading on the local stress ratio, the local temperature, and the stick-slip behaviors.
Tian, Pengyi; Tao, Dashuai; Yin, Wei; Zhang, Xiangjun; Meng, Yonggang; Tian, Yu
2016-01-01
Comprehension of stick-slip motion is very important for understanding tribological principles. The transition from creep-dominated to inertia-dominated stick-slip as the increase of sliding velocity has been described by researchers. However, the associated micro-contact behavior during this transition has not been fully disclosed yet. In this study, we investigated the stick-slip behaviors of two polymethyl methacrylate blocks actively modulated from the creep-dominated to inertia-dominated dynamics through a non-uniform loading along the interface by slightly tilting the angle of the two blocks. Increasing the tilt angle increases the critical transition velocity from creep-dominated to inertia-dominated stick-slip behaviors. Results from finite element simulation disclosed that a positive tilt angle led to a higher normal stress and a higher temperature on blocks at the opposite side of the crack initiating edge, which enhanced the creep of asperities during sliding friction. Acoustic emission (AE) during the stick-slip has also been measured, which is closely related to the different rupture modes regulated by the distribution of the ratio of shear to normal stress along the sliding interface. This study provided a more comprehensive understanding of the effect of tilted non-uniform loading on the local stress ratio, the local temperature, and the stick-slip behaviors. PMID:27641908
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yooa, Junsoo; Estrada-Perez, Carlos E.; Hassan, Yassin A.
In this second of two companion papers presents an analysis of sliding bubble and wall heat transfer parameters measured during subcooled boiling in a square, vertical, upward flow channel. Bubbles were generated only from a single nucleation site for better observation of both the sliding bubbles’ characteristics and their impact on wall heat transfer through optical measurement techniques. Specific interests include: (i) bubbles departure and subsequent growth while sliding, (ii) bubbles release frequency, (iii) coalescence of sliding bubbles, (iv) sliding bubbles velocity, (v) bubbles size distribution and (vi) wall heat transfer influenced by sliding bubbles. Our results showed that slidingmore » bubbles involve two distinct growth behaviors: (i) at low mass fluxes, sliding bubbles grew fast near the nucleation site, subsequently shrank, and then grew again, (ii) as mass flux increased, however, sliding bubbles grew more steadily. The bubbles originating from the single nucleation site coalesced frequently while sliding, which showed close relation with bubbles release frequency. The sliding bubble velocity near the nucleation site consistently decreased by increasing mass flux, while the observation often became reversed as the bubbles slid downstream due to the effect of interfacial drag. The sliding bubbles moved faster than the local liquid (i.e., ur<0) at low mass flux conditions, but it became reversed as the mass flux increased. The size distribution of sliding bubbles followed Gaussian distribution well both near and far from the nucleation site. The standard deviation of bubble size varied insignificantly through sliding compared to the changes in mean bubble size. Lastly, the sliding bubbles enhanced the wall heat transfer and the effect became more noticeable as inlet subcooling/mass flux decreased or wall heat flux increased. Particularly, the sliding bubble characteristics such as bubble growth behavior observed near the nucleation site played a dominant role in determining the ultimate level of wall heat transfer enhancement within the test channel.« less
Yooa, Junsoo; Estrada-Perez, Carlos E.; Hassan, Yassin A.
2016-04-28
In this second of two companion papers presents an analysis of sliding bubble and wall heat transfer parameters measured during subcooled boiling in a square, vertical, upward flow channel. Bubbles were generated only from a single nucleation site for better observation of both the sliding bubbles’ characteristics and their impact on wall heat transfer through optical measurement techniques. Specific interests include: (i) bubbles departure and subsequent growth while sliding, (ii) bubbles release frequency, (iii) coalescence of sliding bubbles, (iv) sliding bubbles velocity, (v) bubbles size distribution and (vi) wall heat transfer influenced by sliding bubbles. Our results showed that slidingmore » bubbles involve two distinct growth behaviors: (i) at low mass fluxes, sliding bubbles grew fast near the nucleation site, subsequently shrank, and then grew again, (ii) as mass flux increased, however, sliding bubbles grew more steadily. The bubbles originating from the single nucleation site coalesced frequently while sliding, which showed close relation with bubbles release frequency. The sliding bubble velocity near the nucleation site consistently decreased by increasing mass flux, while the observation often became reversed as the bubbles slid downstream due to the effect of interfacial drag. The sliding bubbles moved faster than the local liquid (i.e., ur<0) at low mass flux conditions, but it became reversed as the mass flux increased. The size distribution of sliding bubbles followed Gaussian distribution well both near and far from the nucleation site. The standard deviation of bubble size varied insignificantly through sliding compared to the changes in mean bubble size. Lastly, the sliding bubbles enhanced the wall heat transfer and the effect became more noticeable as inlet subcooling/mass flux decreased or wall heat flux increased. Particularly, the sliding bubble characteristics such as bubble growth behavior observed near the nucleation site played a dominant role in determining the ultimate level of wall heat transfer enhancement within the test channel.« less
Grau, Roberto R; de Oña, Paula; Kunert, Maritta; Leñini, Cecilia; Gallegos-Monterrosa, Ramses; Mhatre, Eisha; Vileta, Darío; Donato, Verónica; Hölscher, Theresa; Boland, Wilhelm; Kuipers, Oscar P; Kovács, Ákos T
2015-07-07
Multicellular biofilm formation and surface motility are bacterial behaviors considered mutually exclusive. However, the basic decision to move over or stay attached to a surface is poorly understood. Here, we discover that in Bacillus subtilis, the key root biofilm-controlling transcription factor Spo0A~Pi (phosphorylated Spo0A) governs the flagellum-independent mechanism of social sliding motility. A Spo0A-deficient strain was totally unable to slide and colonize plant roots, evidencing the important role that sliding might play in natural settings. Microarray experiments plus subsequent genetic characterization showed that the machineries of sliding and biofilm formation share the same main components (i.e., surfactin, the hydrophobin BslA, exopolysaccharide, and de novo-formed fatty acids). Sliding proficiency was transduced by the Spo0A-phosphorelay histidine kinases KinB and KinC. We discovered that potassium, a previously known inhibitor of KinC-dependent biofilm formation, is the specific sliding-activating signal through a thus-far-unnoticed cytosolic domain of KinB, which resembles the selectivity filter sequence of potassium channels. The differential expression of the Spo0A~Pi reporter abrB gene and the different levels of the constitutively active form of Spo0A, Sad67, in Δspo0A cells grown in optimized media that simultaneously stimulate motile and sessile behaviors uncover the spatiotemporal response of KinB and KinC to potassium and the gradual increase in Spo0A~Pi that orchestrates the sequential activation of sliding, followed by sessile biofilm formation and finally sporulation in the same population. Overall, these results provide insights into how multicellular behaviors formerly believed to be antagonistic are coordinately activated in benefit of the bacterium and its interaction with the host. Alternation between motile and sessile behaviors is central to bacterial adaptation, survival, and colonization. However, how is the collective decision to move over or stay attached to a surface controlled? Here, we use the model plant-beneficial bacterium Bacillus subtilis to answer this question. Remarkably, we discover that sessile biofilm formation and social sliding motility share the same structural components and the Spo0A regulatory network via sensor kinases, KinB and KinC. Potassium, an inhibitor of KinC-dependent biofilm formation, triggers sliding via a potassium-perceiving cytosolic domain of KinB that resembles the selectivity filter of potassium channels. The spatiotemporal response of these kinases to variable potassium levels and the gradual increase in Spo0A~Pi levels that orchestrates the activation of sliding before biofilm formation shed light on how multicellular behaviors formerly believed to be antagonistic work together to benefit the population fitness. Copyright © 2015 Grau et al.
Stick-slip Cycles and Tidal Modulation of Ice Stream Flow
NASA Astrophysics Data System (ADS)
Lipovsky, B.; Dunham, E. M.
2016-12-01
The reactivation of a single dormant Antarctic ice stream would double the continent's mass imbalance. Despite importance of understanding the likelihood of such an event, direct observation of the basal processes that lead to the activation and stagnation of streaming ice are minimal. As the only ice stream undergoing stagnation, the Whillans Ice Plain (WIP) occupies a central role in our understanding of these subglacial processes. Complicating matters is the observation, from GPS records, that the WIP experiences most of its motion during episodes of rapid sliding. These sliding events are tidally modulated and separated by 12 hour periods of quiescence. We conduct numerical simulations of ice stream stick-slip cycles. Our simulations include rate- and state-dependent frictional sliding, tidal forcing, inertia, upstream loading in a cross-stream, thickness-averaged formulation. Our principal finding is that ice stream motion may respond to ocean tidal forcing with one of two end member behaviors. In one limit, tidally modulated slip events have rupture velocities that approach the shear wave speed and slip events have a duration that scales with the ice stream width divided by the shear wave speed. In the other limit, tidal modulation results in ice stream sliding velocities with lower amplitude variation but at much longer timescales, i.e. semi-diurnal and longer. This latter behavior more closely mimics the behavior of several active ice streams (Bindschadler, Rutford). We find that WIP slip events exist between these two end member behaviors: rupture velocities are far below the inertial limit yet sliding occurs only episodically. The continuum of sliding behaviors is governed by a critical ice stream width over which slip event nucleate. When the critical width is much longer than the ice stream width, slip events are unable to nucleate. The critical width depends on the subglacial effective pressure, ice thickness, and frictional and elastic constitutive parameters. One implication of our work is that, because the transition from steady to episodic sliding may occur by changing subglacial effective pressure, changing effective pressure may be responsible for the stagnation of the WIP.
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Wheeler, Donald R.; Zabinski, Jeffrey S.
1996-01-01
An investigation was conducted to examine the surface chemistry, friction, and wear behavior of untreated and annealed tungsten disulfide (WS2) coatings in sliding contact with a 6-mm-diameter 440C stainless-steel ball. The WS2 coatings and annealing were performed using the pulsed-laser-deposition technique. All sliding friction experiments were conducted with a load of 0.98 N (100 g), an average Hertzian contact pressure of 0.44 GPa, and a constant rotating speed of 120 rpm. The sliding velocity ranged from 31 to 107 mm/s because of the range of wear track radii involved in the experiments. The experiment was performed at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7X(exp -10) Pa), dry nitrogen (relative humidity, less than 1 percent), and humid air (relative humidity, 15 to 40 percent). Analytical techniques, including scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), x-ray photo electron spectroscopy (XPS), surface profilometry, and Vickers hardness testing, were used to characterize the tribological surfaces of WS2 coatings. The results of the investigation indicate that the laser annealing decreased the wear of a WS2 coating in an ultrahigh vacuum. The wear rate was reduced by a factor of 30. Thus, the laser annealing increased the wear life and resistance of the WS2 coating. The annealed WS 2 coating had a low coefficient of friction (less than O.1) and a low wear rate ((10(exp -7) mm(exp 3)/N-m)) both of which are favorable in an ultrahigh vacuum.
Proctor, Brooks; Lockner, David A.; Lowenstern, Jacob B.; Beeler, Nicholas M.
2018-01-01
Coseismic frictional melting and the production of quenched glass called pseudotachylyte is a recurring process during earthquakes. To investigate how glassy materials affect the postseismic strength and stability of faults, obsidian gouges were sheared under dry and wet conditions from 200°C to 300°C at ~150 MPa effective normal stress. Dry glass exhibited a brittle rheology at all conditions tested, exhibiting friction values and microstructures consistent with siliciclastic materials. Likewise, wet glass at 200°C exhibited a brittle rheology. In contrast, wet gouges at 300°C transitioned from brittle sliding to linear‐viscous (Newtonian) flow at strain rates <3 × 10−4 s−1, indicating melt‐like behavior. The viscosity ranged from 2 × 1011 to 7.8 × 1011 Pa‐s. Microstructures show that viscous gouges were fully welded with rod‐shaped microlites rotated into the flow direction. Fourier transform infrared spectroscopy along with electron backscatter imaging demonstrate that hydration of the glass by diffusion of pore water was the dominant process reducing the viscosity and promoting viscous flow. As much as 5 wt % water diffused into the glass. These results may provide insight into postseismic‐slip behaviors and challenge some interpretations of fault kinematics based on studies assuming that pseudotachylyte formation and flow is solely coseismic.
MicroTribological Performance of Au-MoS2 and Ti-MoS2 Coatings with Varying Contact Pressure
2011-02-15
Dvorak, S.D., Wahl, K.J., Singer, I.L.: In situ analysis of third body contributions to sliding friction of a Pb-Mo-S coating in dry and humid air...University, Montreal. QC H3A 2B2, Canada e-mail: richard.chromik@mcgill.ca J. R. Lince Tribology Section, Spacecraft Materials Laboratory, The Aerospace...than a decade, the testing of nano- and micro-scale sliding contacts has been an important research area that seeks to improve the tribological
NASA Astrophysics Data System (ADS)
Jiang, Xieqiang; Wan, Jie; Han, Haoxu; Wang, Yiping; Li, Kang; Wang, Qingjun
2018-09-01
Ordered nanoball matrix fluorocarbon polymer layers were produced with two different fluorocarbon polymers on an anodized aluminum oxide (AAO) surface. These treated surfaces each exhibited hydrophobicity or superhydrophobicity. The dynamic behavior of a droplet sliding down these surfaces was captured by high-speed photography under simulated weather conditions including at room temperature (25 °C) and low temperature (5 °C) with various relative humidities (30%-80%). By analyzing the trajectory of a marker in the captured video frame-by-frame, we distinguished the slipping and rolling behaviors and analyzed the internal fluidity by calculating the ratio of these two motions. Both the pore diameters of the substrate matrix and the environmental conditions play a dominant role in the resultant sliding acceleration of a water droplet. At room temperature (25 °C) and 30% relative humidity, the sliding acceleration of the droplet on the fluoropolymer layer decreased by 0.5 m·s-2 -0.6 m·s-2 as the pore diameters of the underlying AAO substrates increased. The sliding acceleration underwent a 25%-50% decrease under extreme environmental conditions (5 °C and 80% RH). These phenomena proved that a wetting transition from the Cassie-Baxter model to the Wenzel model can partially occur under various weather conditions.
Friction and Wear Properties of Selected Solid Lubricating Films
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Iwaki, Masanori; Gotoh, Kenichi; Obara, Shingo; Imagawa, Kichiro
1999-01-01
To evaluate commercially developed solid film lubricants for aerospace bearing applications, we investigated the friction and wear behavior of bonded molybdenum disulfide (MoS2), magnetron-sputtered MoS2 and ion-plated silver films in sliding contact with 6-mm-diameter American Iron and Steel Institute (AISI) 440 C stainless steel balls. Unidirectional sliding friction experiments were conducted with a load of 5.9 N (600 g), a mean Herizian contact pressure of 0.79 GPa maximum 1.19 GPa), and a sliding velocity of 0.2 m/s at room temperature in three environments: ultrahigh vacuum (7x10 (exp -7Pa)), humid air (approx. 20 percent humidity), and dry nitrogen (less than 1 percent humidity). The resultant films were characterized by scanning electron microscopy, energy-dispersive x-ray spectroscopy, and surface profilometry. Marked differences in friction and wear resulted front the environmental conditions and the film materials. The main criteria for judging the performance were coefficient of friction and wear rate, which had to be less than 0.3 and on the order of 10 (exp -6mm exp 3/Nm or less), respectively. The bonded MoS2 and magnetron-sputtered MoS2 films met the criteria in all three environments. Also, the wear rates of the counterpart AISI 440 C stainless steel balls met that criterion in all three environments. The ion-plated silver films met the criteria only in ultrahigh vacuum. In ultrahigh vacuum the bonded MoS2 films were superior. In humid air the bonded MoS2 films had higher coefficient of friction and shorter wear life than did the magnetron-sputtered MoS2 films. The ion-plated silver films had a high coefficient of friction in humid air but relatively low coefficients of friction in the nonoxidative environments. Adhesion and plastic deformation played important roles in all three environments. All sliding involved adhesive transfer of materials.
de Oña, Paula; Kunert, Maritta; Leñini, Cecilia; Gallegos-Monterrosa, Ramses; Mhatre, Eisha; Vileta, Darío; Hölscher, Theresa; Kuipers, Oscar P.
2015-01-01
ABSTRACT Multicellular biofilm formation and surface motility are bacterial behaviors considered mutually exclusive. However, the basic decision to move over or stay attached to a surface is poorly understood. Here, we discover that in Bacillus subtilis, the key root biofilm-controlling transcription factor Spo0A~Pi (phosphorylated Spo0A) governs the flagellum-independent mechanism of social sliding motility. A Spo0A-deficient strain was totally unable to slide and colonize plant roots, evidencing the important role that sliding might play in natural settings. Microarray experiments plus subsequent genetic characterization showed that the machineries of sliding and biofilm formation share the same main components (i.e., surfactin, the hydrophobin BslA, exopolysaccharide, and de novo-formed fatty acids). Sliding proficiency was transduced by the Spo0A-phosphorelay histidine kinases KinB and KinC. We discovered that potassium, a previously known inhibitor of KinC-dependent biofilm formation, is the specific sliding-activating signal through a thus-far-unnoticed cytosolic domain of KinB, which resembles the selectivity filter sequence of potassium channels. The differential expression of the Spo0A~Pi reporter abrB gene and the different levels of the constitutively active form of Spo0A, Sad67, in Δspo0A cells grown in optimized media that simultaneously stimulate motile and sessile behaviors uncover the spatiotemporal response of KinB and KinC to potassium and the gradual increase in Spo0A~Pi that orchestrates the sequential activation of sliding, followed by sessile biofilm formation and finally sporulation in the same population. Overall, these results provide insights into how multicellular behaviors formerly believed to be antagonistic are coordinately activated in benefit of the bacterium and its interaction with the host. PMID:26152584
Experimentally determined wear behavior of an Al2O3-SiC composite from 25 to 1200 C
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher; Farmer, Serene C.; Book, Patricia O.
1990-01-01
The sliding wear behavior of a self-mated alumina-silicon carbide whisker toughened composite was studied using optical, scanning electron (SEM) and transmission electron (TEM) microscopy. Because of its excellent strength and toughness properties this composite material is under consideration for use in heat engine applications for sliding contacts which operate at elevated temperatures. The composite's wear behavior and especially its wear mechanisms are not well understood. Pin-on-disk specimens were slid in air at 2.7 m/s sliding velocity, under a 26.5-N load, at temperatures 25 to 1200 C. Pin wear increased with increasing temperature. Based upon the microscopic analyses, the wear mechanism seems to be loosening of the reinforcing whiskers due to frictional and bulk heating. This leads to whisker pullout and increased wear.
Relative sliding durability of candidate high temperature fiber seal materials
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher; Steinetz, Bruce M.
1992-01-01
The relative sliding durability behavior of six candidate ceramic fibers for high temperature sliding seal applications is reviewed and compared. Pin on disk tests were used to evaluate potential seal materials by sliding a tow or bundle of the candidate ceramic fiber against a superalloy test disk. Tests were conducted in air under a 2.65 N load, at a sliding velocity of 0.025 m/sec and at temperatures from 25 to 900 C. Friction was measured during the tests and fiber wear, indicated by the extent of fibers broken in the tow or bundle, was measured at the end of each test. For most of the fibers, friction and wear increase with test temperature. The relative fiber durability ranking correlates with tensile strength, indicating that tensile data, which is more readily available than sliding durability data, may be useful in predicting fiber wear behavior under various conditions. A dimensional analysis of the wear data shows that the fiber durability is related to a dimensionless durability ratio which represents the ratio of the fiber strength to the fiber stresses imposed by sliding. The analysis is applicable to fibers with similar diameters and elastic moduli. Based upon the results of the research program, three fiber candidates are recommended for further study as potential seal materials. They are a silicon based complex carbide-oxide fiber, an alumina-boria-silica and an aluminosilicate fiber.
NASA Astrophysics Data System (ADS)
Chen, Lianfeng; Zheng, Tianran; Chen, Qing; Zhang, Jun
2013-12-01
Advanced high strength steels (AHSS) are used more and more in automotive industry for increasing crashworthiness and weight reduction. Improving metal flow and reduce friction are important to forming the part and decrease part reject rates of AHSS. The present study focused on friction characteristics and drawbead restraining force of Dual Phase (DP) steels with or without coating, such as DP980, DP780, DP590, DP780+Z, DP780+ZF, DP590+Z, using experimental approach. The effect of material properties, temperature, sliding velocity, surface roughness, dry and lubricant on friction behavior of DP steels is investigated. The contrast of DP steels with mild IF steel is carried out. The restraining force draw through different radius of drawbead is evaluated. This study is benefit to the set up of technique parameters during sheet metal forming simulation.
NASA Astrophysics Data System (ADS)
Kumar, Suresh; Pandey, O. P.
Metal foams cellular metals have gained an important role in the field of metallurgy, though barely a few decades old. Aluminum composite foam exhibit unique properties such as light weight, blast palliation, sound absorption, high energy absorption, and flame resistance. In the present investigation the effect of variation in the amount of CaCO3 as blowing agent on the microstructure and wear behavior of LM13 alloy foams has been studied. The blowing agent was blended in highly viscous semi-solid melt by stirring process. The process parameters that influence the formation of bubbles like the melt temperature, size and amount of blowing agent and its distribution has been optimized to get uniform size foams. The distribution behavior of blowing agent is influenced by the melt viscosity and stirring speed. For packaging application, the dry sliding wear behavior of the prepared foam was investigated by using a pin on disc method at applied loads of 9.8, 19.6 and 29.4 N at room temperature. The results indicate that the wear rate is dependent on the cell size and cell wall thickness of the foam.
Adaptive sliding mode control for a class of chaotic systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farid, R.; Ibrahim, A.; Zalam, B., E-mail: ramy5475@yahoo.com
2015-03-30
Chaos control here means to design a controller that is able to mitigating or eliminating the chaos behavior of nonlinear systems that experiencing such phenomenon. In this paper, an Adaptive Sliding Mode Controller (ASMC) is presented based on Lyapunov stability theory. The well known Chua's circuit is chosen to be our case study in this paper. The study shows the effectiveness of the proposed adaptive sliding mode controller.
Qu, Jun; Blau, Peter J.; Higdon, Clifton; ...
2016-03-29
We investigated friction behavior of a bearing system with two interfaces involved: a roller component experiencing rolling–sliding interaction against twin cylinders under point contacts while simultaneously undergoing pure sliding interaction against a socket under a conformal contact. Lubrication modeling predicted a strong correlation between the roller's rolling condition and the system's friction behavior. Experimental observations first validated the analytical predictions using steel and iron components. Diamond-like-carbon (DLC) coating and AlMgB 14–TiB 2 coating with a carbon topcoat (BAMC) were then applied to the roller and twin cylinders, respectively. In conclusion, testing and analysis results suggest that the coatings effectively decreasedmore » the slip ratio for the roller–cylinder contact and the sliding friction at both bearing interfaces and, as a result, significantly reduced the system frictional torque.« less
In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding
NASA Astrophysics Data System (ADS)
Savalani, M. M.; Ng, C. C.; Li, Q. H.; Man, H. C.
2012-01-01
Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.
Enhancing tribological performance of Ti-6Al-4V using pin on disc setup
NASA Astrophysics Data System (ADS)
Kumar, Deepak; Lijesh, K. P.; Deepak, K. B.; Kumar, Satish
2018-05-01
Titanium (Ti) alloy Ti-6Al-4V (Ti64), possesses a inimitable combination of mechanical, physical and corrosion properties, which makes them desirable for applications like aerospace, automobile, chemical and energy industries devices etc. However this alloy of Ti exhibits poor tribological (friction and wear) properties, which limits their full fledged implementation. However, the tribological behavior of T164 can be enhanced by providing a coating or a protective layer on it, which posses superior tribological properties. It is hypothesized that by a layer of alumina on the can be deposited on the surface of Ti64, by sliding them in dry-ambient condition using Pin On Disk (POD) machine. To validate the hypothesis, experiments were performed for different normal loading conditions of 13.7N, 68.7N and 109.9N at sliding speed of 0.01m/s and for a sliding distance of 1000m. The tribological performance of the experiments, were evaluated by measuring Coefficient of Friction (COF) and weight loss values. To understand the tribological mechanism and behaviour, In-situ analysis was performed on the pin using (i) Scanning Electron Microscopy (SEM) to understand the wear morphology, and (ii) Energy Dispersive Analysis of X Ray (EDAX) to estimate the deposition of alumina on surface of the pins. Based on the obtained results, the most favorable experimenting condition required for deposition of alumina over Ti64 will be identified. Finally, experiment on POD will be repeated for the selected experimenting condition and will be continued for the worst tribological condition. The obtained COF and wear values after performing the experiment will be presented.
Fabrication and Tribological Behavior of Stir Cast Mg/B4C Metal Matrix Composites
NASA Astrophysics Data System (ADS)
Singh, Amandeep; Bala, Niraj
2017-10-01
Magnesium-based metal matrix composites (MMMCs) have emerged as good alternative material to conventional materials due to their promising advanced properties. In the present work, magnesium-based metal matrix composites (MMMCs) reinforced with B4C particles were successfully fabricated by cost-effective conventional stir casting technique. MMMCs with an average particle size of 63 µm and different weight percent (wt pct) of B4C between 3 and 12 were fabricated. Wear tests were carried out using a pin-on-disk against a steel disk under dry sliding condition at loads that varied between 1 and 5 kg at fixed sliding velocity of 1 m/s. The wear data clearly showed that wear resistance of cast composites is better than that of unreinforced magnesium, which is attributed to dispersion hardening caused by carbide particles. An increase in wt pct of B4C showed the wear resistance and hardness to increase significantly. The wear rate and coefficient of friction increased with an increase in applied load. The SEM and EDS analysis of the worn surfaces delineated the dominant wear mechanisms to be abrasion, adhesion, and oxidation under the different sliding conditions. At lower loads, the wear mechanism transformed from severe abrasive wear in pure magnesium (Mg) to mild abrasion, slight delamination, and oxidation in the Mg/12 wt pct B4C fabricated composite. At higher loads, severe abrasion, adhesion, delamination, and oxidation were found to be the major wear mechanisms in pure Mg, whereas in the Mg/12 wt pct B4C fabricated composites the corresponding mechanisms were mild abrasion, mild adhesion, slight delamination, and oxidation.
Friction Reduction in Powertrain Materials: Role of Tribolayers
NASA Astrophysics Data System (ADS)
Banerji, Anindya
This study aims at understanding the micromechanisms responsible for reduction in friction and wear in the engine cylinder bore/liner materials when tested under lubricated and unlubricated conditions. The tribolayers formed in-situ during sliding contact are unique to each tribosystem and a detailed study of these tribolayers will shed light on the friction reduction mechanisms in powertrain materials. Boundary lubricated tribological performance of grey cast iron (CI) tested against non-hydrogenated diamond-like carbon coating (NH-DLC) resulted in 21% lower coefficient of friction (COF) and an order of magnitude lower volumetric wear compared to CI and steel counterfaces. Dilution of the engine oil by ethanol containing E85 biofuel, consisting of 85% ethanol and 15% gasoline, was beneficial as COF and volumetric wear losses were further reduced. TEM/EELS studies of the NH-DLC counterface provided evidence for OH adsorption of the dangling carbon bonds at the coating surface leading to low friction. Advantage of E85/engine oil blend was also evident during boundary lubricated sliding of eutectic Al-12.6% Si alloy against AISI 52100 steel. The oil residue layer (ORL) formed during boundary lubricated sliding incorporated nanocrystalline regions of Al, Si, ZnS, AlPO4 and ZnO surrounded by amorphous carbon regions. Higher proportions of Zn, S, and P antiwear compounds formed in the ORL when tested using the E85/oil (1:1) blend compared to the unmixed engine oil as the hydroxyl groups in ethanol molecules facilitated ZDDP degradation. Mico-Raman spectroscopy indicated two types of tribolayers formed during unlubricated sliding of thermally sprayed low carbon steel 1010 coating deposited on linerless Al 380 cylinder bore: i) Fe2O3 layer transformed from FeO during dry sliding and ii) Fe2O3 layer with a top amorphous carbon transfer layer when run against H-DLC coated TCR with COF of 0.18. The NH- and H-DLC coatings, that provide low friction under room temperature conditions, fail at temperatures > 200 °C. It was shown that W containing DLC (W-DLC) coatings offered low and stable COF of 0.07 at 400 °C while a Ti incorporated multilayer MoS2 (Ti-MoS2) coating maintained COF between 0.11 at 25 °C to 0.13 at 350 °C. The low friction provided by these coatings was attributed to formation of high temperature lubricious oxides: tungsten trioxide (WO3) in case of W-DLC and MoO3 in case of MoS2, as revealed by Raman analyses of the tribolayers formed on counterface surfaces. Tribolayer formation during sliding friction of multuilayered graphene (MLG), a potential lubricant, depended on the material transfer and relative humidity (RH). Sliding friction tests performed on MLG in air (10- 45% RH) and under a dry N2 atmosphere showed that progressively lower friction values were observed when the RH was increased, with maximum COF of 0.52 in dry N2 and lowest COF of about 0.10 at 45% RH. Microstructural studies including cross-sectional FIB/HR-TEM determined that sliding induced defects which comprised of edge fracture, fragmented/bent graphene stacks compared to pristine graphene and disordered regions between them. In summary, this work shows that delineating the micromechanisms responsible for reduction in friction and wear is critical for development of appropriate materials and coatings for powertrain components.
Tribology of carbide derived carbon films synthesized on tungsten carbide
NASA Astrophysics Data System (ADS)
Tlustochowicz, Marcin
Tribologically advantageous films of carbide derived carbon (CDC) have been successfully synthesized on binderless tungsten carbide manufactured using the plasma pressure compaction (P2CRTM) technology. In order to produce the CDC films, tungsten carbide samples were reacted with chlorine containing gas mixtures at temperatures ranging from 800°C to 1000°C in a sealed tube furnace. Some of the treated samples were later dechlorinated by an 800°C hydrogenation treatment. Detailed mechanical and structural characterizations of the CDC films and sliding contact surfaces were done using a series of analytical techniques and their results were correlated with the friction and wear behavior of the CDC films in various tribosystems, including CDC-steel, CDC-WC, CDC-Si3N4 and CDC-CDC. Optimum synthesis and treatment conditions were determined for use in two specific environments: moderately humid air and dry nitrogen. It was found that CDC films first synthesized at 1000°C and then hydrogen post-treated at 800°C performed best in air with friction coefficient values as low as 0.11. However, for dry nitrogen applications, no dechlorination was necessary and both hydrogenated and as-synthesized CDC films exhibited friction coefficients of approximately 0.03. A model of tribological behavior of CDC has been proposed that takes into consideration the tribo-oxidation of counterface material, the capillary forces from adsorbed water vapor, the carbon-based tribofilm formation, and the lubrication effect of both chlorine and hydrogen.
NASA Astrophysics Data System (ADS)
Liu, Longfei; Yang, Jun
2017-12-01
Zr55Cu30Al10Ni5 bulk metallic glass and its composites were prepared by suction casting into a copper mold. The effect of MoSi2 content on the tribological behavior of Zr55Cu30Al10Ni5 BMG was studied by using a high-speed reciprocating friction and wear tester. The results indicate that the friction coefficient and wear resistance of the BMGs can be improved by a certain amount of crystalline phase induced by MoSi2 content from 1 to 3% and deteriorated with MoSi2 content of 4%. The wear mechanism of both the metallic glass and its composite is abrasive wear. The mechanism of crystalline phase-dependent tribological properties of the composite was discussed based on the wear track and mechanical properties in the present work. The wear behavior of Zr55Cu30Al10Ni5 BMG and its composite indicates that a good combination of the toughness and the hardness can make the composite be well wear resistant.
Surface temperatures and glassy state investigations in tribology, part 1
NASA Technical Reports Server (NTRS)
Winer, W. O.; Sanborn, D. M.
1978-01-01
The research in this report is divided into two categories: (1) lubricant rheological behavior, and (2) thermal behavior of a simulated elastohydrodynamic contact. The studies of the lubricant rheological behavior consists of high pressure, low shear rate viscosity measurements, viscoelastic transition measurements, by volume dilatometry, dielectric transitions at atmospheric pressure and light scattering transitions. Lubricant shear stress-strain behavior in the amorphous glassy state was measured on several fluids. It appears clear from these investigations that many lubricants undergo viscoplastic transitions in typical EHD contacts and that the lubricant has a limiting maximum shear stress it can support which in turn will determine the traction in the contact except in cases of very low slide-roll ratio. Surface temperature measurements were made for a naphthenic mineral oil and a polyphenyl ether. The maximum surface temperature in these experiments was approximately symmetrical about the zero slide-roll ration except for absolute values of slide-roll ratio greater than about 0.9. Additional surface temperature measurements were made in contacts with rough surfaces where the composite surface roughness was approximately equal to the EHD film thickness. A regression analysis was done to obtain a predictive equation for surface temperatures as a function of pressure, sliding speed, and surface roughness. A correction factor for surface roughness effects to the typical flash temperature analysis was found.
Study of confinement and sliding friction of fluids using sum frequency generation spectroscopy
NASA Astrophysics Data System (ADS)
Nanjundiah, Kumar
2007-12-01
Friction and wear are important technologically. Tires on wet roads, windshield wipers and human joints are examples where nanometer-thick liquids are confined between flexible-rigid contact interfaces. Fundamental understanding of the structure of these liquids can assist in the design of products such as artificial joints and lubricants for Micro-electromechanical systems [MEMS]. Prior force measurements have suggested an increase in apparent viscosity of confined liquid and sometimes solid-like responses. But, these have not given the state of molecules under confinement. In the present study, we have used a surface sensitive, non-linear optical technique (infrared-visible sum frequency generation spectroscopy [SFG]) to investigate molecular structure at hidden interfaces. SFG can identify chemical groups, concentration and orientation of molecules at an interface. A friction cell was developed to study sliding of a smooth elastomeric lens against a sapphire surface. Experiments were done with dry sliding as well as lubricated sliding in the presence of linear alkane liquids. SFG spectra at the alkane/sapphire interface revealed ordering of the confined alkane molecules. These were more ordered than alkane liquid, but less ordered than alkane crystal. Cooling of the confined alkane below its melting temperature [TM] led to molecular orientation that was different from that of bulk crystal next to a sapphire surface. Molecules were oriented with their symmetry axis parallel to the surface normal. In addition, the melting temperature [Tconf] under confinement for a series of linear alkanes (n =15--27) showed a surprising trend. Intermediate molecular weights showed melting point depression. The T conf values suggested that melting started at the alkane/sapphire interface. In another investigation, confinement of water between an elastomeric PDMS lens and sapphire was studied. SFG spectra at the sapphire/water/PDMS interface revealed a heterogeneous morphology. The presence of peaks related to PDMS, as well as water, suggested water puddles in the contact area and the sapphire surface had a layer of bound water. This heterogeneity picture provides insight into high friction and stick-slip behavior found in boundary lubrication. For the first time, a broadband SFG system has been coupled with a friction cell to study dynamics and molecular changes at an interface during sliding; sliding of confined alkane between sapphire and PDMS was investigated. A series of SFG spectra were taken while the confined alkane contact spot moved in and out of the laser beam. Even though the experiments were done 15°C above melting temperature, the spectra showed ordering of alkane molecules, similar to that of the confined crystal at the leading and trailing edge. The results suggest that a large portion of the resistance to sliding may come from ordering of molecules at the lens front.
NASA Astrophysics Data System (ADS)
Panin, S. V.; Kornienko, L. A.; Buslovich, D. G.; Alexenko, V. O.; Ivanova, L. R.
2017-12-01
To determine the limits of the operation loading intervals appropriate for the use of solid lubricant UHMWPE composites in tribounits for mechanical engineering and medicine, the tribotechnical properties of UHMWPE blends with the optimum solid lubricant filler content (polytetrafluoroethylene, calcium stearate, molybdenum disulfide, colloidal graphite, boron nitride) are studied under dry sliding friction at different velocities (V = 0.3 and 0.5 m/s) and loads (P = 60 and 140 N). It is shown that the wear resistance of solid lubricant UHMWPE composites at moderate sliding velocities (V = 0.3 m/s) and loads (P = 60 N) increases 2-3 times in comparison with pure UHMWPE, while at high load P = 140 N wear resistance of both neat UHMWPE and its composites is reduced almost twice. At high sliding velocities and loads (up to P = 140 N), multiple increasing of the wear of pure UHMWPE and its composites takes place (by the factor of 5 to 10). The operational conditions of UHMWPE composites in tribounits in engineering and medicine are discussed.
Kawasaki, S; Tada, T; Persson, B N J
2018-06-27
We study the contact mechanics between 3 different tire tread compounds and a smooth glass surface in water. We study both adhesion and sliding friction at low-sliding speeds. For 2 of the compounds the rubber-glass contact in water is hydrophobic and we observe adhesion, and slip-stick sliding friction dynamics. For one compound the contact is hydrophilic, resulting in vanishing adhesion, and steady-state (or smooth) sliding dynamics. We also show the importance of dynamical scrape, both on the macroscopic level and at the asperity level, which reduces the water film thickness between the solids during slip. The experiments show that the fluid is removed much faster from the rubber-glass asperity contact regions for a hydrophobic contact than for a hydrophilic contact. We also study friction on sandblasted glass in water. In this case all the compounds behave similarly and we conclude that no dewetting occur in the asperity contact regions. We propose that this is due to the increased surface roughness which reduces the rubber-glass binding energy.
Determination of mechanical behavior of nanoscale materials using molecular dynamics simulations
NASA Astrophysics Data System (ADS)
Heo, Seongjun
It is important to understand the mechanical properties of nanometer-scale materials for use in such applications as microelectromechanical systems (MEMS) and nanoelectromechanical systems (NEMS). These properties are difficult to measure directly using experimental methods due to their small sizes. Computational simulations provide important insights that complement experimental data and lead to improved understanding of the mechanical properties of nanometer-scale systems. Molecular dynamics (MD) simulations, which are used to investigate the properties of materials at the atomic scale, is used in my research to determine (1) best thermostat managing way for acceptable mechanical behavior of nanoscale systems; (2) filling effect on the bending and compressive properties of carbon nanotubes (CNTs); (3) vibrational behavior of bridged and cantilevered CNT bombarded by external fluid atoms; (4) frictional behavior of filled CNT bundles and the effect of external molecules on friction; (5) effect of sliding orientations on the tribological properties of polyethylene (PE). In all the simulations the reactive empirical bond-order (REBO) potential combined with the Lennard Jones potential is applied to control inter-atomic interactions. During the MD simulations, thermostats are used to maintain the system temperature at a constant value. Tests indicate that the simulations describe the mechanical behavior of CNTs differently depending on the type of thermostat used, and the relative fraction of the system to which the thermostat is applied. The results indicate that Langevin and velocity rescaling thermostats are more reliable for temperature control than the Nose-Hoover thermostat. In examining CNT bending and compression, the simulations predict filled CNTs are more resistant to external bending and compressive forces than hollow CNTs. The mechanical properties deteriorate with increases in temperature and number of CNT wall defects. MD simulations of the vibrational behavior of bridged and cantilevered CNTs are found to match the results of continuum mechanics calculations. The principal vibration frequency of the CNT is predicted to decrease with increasing nanotube length, gas pressure, and the atomic mass of the external fluid. In studies of CNT tribology, simulations show that two layers of filled CNTs are more resistant to compressive forces and exhibit lower friction coefficients during sliding than unfilled CNTs. The friction coefficient increases with the thickness of the CNT layer due to the increase in effective friction interface. The addition of an external, molecular fluid of benzene molecules is predicted to reduce the friction coefficient of CNTs because of the lubricity of the molecules. Lastly, simulation results illustrate the effect of relative orientation on the tribological properties of polyethylene (PE) sliding surfaces. The friction coefficient of perpendicular sliding is much higher than that of parallel sliding based on the polymer chain orientation. The PE exhibits stick-slip motion during sliding regardless of the sliding orientation. In addition, the PE shows no surface morphology change due to the higher strength of the PE bonds, which is in contrast to the behavior of other polymers, such as polytetrafluoroethylene (PTFE), which exhibits bond breaking and realignment of surface chains along the sliding direction in the less favorable orientation.
Creep model of unsaturated sliding zone soils and long-term deformation analysis of landslides
NASA Astrophysics Data System (ADS)
Zou, Liangchao; Wang, Shimei; Zhang, Yeming
2015-04-01
Sliding zone soil is a special soil layer formed in the development of a landslide. Its creep behavior plays a significant role in long-term deformation of landslides. Due to rainfall infiltration and reservoir water level fluctuation, the soils in the slide zone are often in unsaturated state. Therefore, the investigation of creep behaviors of the unsaturated sliding zone soils is of great importance for understanding the mechanism of the long-term deformation of a landslide in reservoir areas. In this study, the full-process creep curves of the unsaturated soils in the sliding zone in different net confining pressure, matric suctions and stress levels were obtained from a large number of laboratory triaxial creep tests. A nonlinear creep model for unsaturated soils and its three-dimensional form was then deduced based on the component model theory and unsaturated soil mechanics. This creep model was validated with laboratory creep data. The results show that this creep model can effectively and accurately describe the nonlinear creep behaviors of the unsaturated sliding zone soils. In order to apply this creep model to predict the long-term deformation process of landslides, a numerical model for simulating the coupled seepage and creep deformation of unsaturated sliding zone soils was developed based on this creep model through the finite element method (FEM). By using this numerical model, we simulated the deformation process of the Shuping landslide located in the Three Gorges reservoir area, under the cycling reservoir water level fluctuation during one year. The simulation results of creep displacement were then compared with the field deformation monitoring data, showing a good agreement in trend. The results show that the creeping deformations of landslides have strong connections with the changes of reservoir water level. The creep model of unsaturated sliding zone soils and the findings obtained by numerical simulations in this study are conducive to reveal the mechanisms of the dynamic process of landslide deformation, and serve as an important basis for the prediction and evaluation of landslides.
Chen, Yizheng; Zhuang, Yiyang; Du, Yang; Gerald, Rex E.; Tang, Yan
2017-01-01
This paper presents an extrinsic Fabry–Perot interferometer-based optical fiber sensor (EFPI) for measuring three-dimensional (3D) displacements, including interfacial sliding and debonding during delamination. The idea employs three spatially arranged EFPIs as the sensing elements. In our sensor, the three EFPIs are formed by three endfaces of three optical fibers and their corresponding inclined mirrors. Two coincident roof-like metallic structures are used to support the three fibers and the three mirrors, respectively. Our sensor was calibrated and then used to monitor interfacial sliding and debonding between a long square brick of mortar and its support structure (i.e., a steel base plate) during the drying/curing process. This robust and easy-to-manufacture triaxial EFPI-based 3D displacement sensor has great potential in structural health monitoring, the construction industry, oil well monitoring, and geotechnology. PMID:29165351
Zhu, Chen; Chen, Yizheng; Zhuang, Yiyang; Du, Yang; Gerald, Rex E; Tang, Yan; Huang, Jie
2017-11-22
This paper presents an extrinsic Fabry-Perot interferometer-based optical fiber sensor (EFPI) for measuring three-dimensional (3D) displacements, including interfacial sliding and debonding during delamination. The idea employs three spatially arranged EFPIs as the sensing elements. In our sensor, the three EFPIs are formed by three endfaces of three optical fibers and their corresponding inclined mirrors. Two coincident roof-like metallic structures are used to support the three fibers and the three mirrors, respectively. Our sensor was calibrated and then used to monitor interfacial sliding and debonding between a long square brick of mortar and its support structure (i.e., a steel base plate) during the drying/curing process. This robust and easy-to-manufacture triaxial EFPI-based 3D displacement sensor has great potential in structural health monitoring, the construction industry, oil well monitoring, and geotechnology.
Otsuki, Michio; Matsukawa, Hiroshi
2013-01-01
In many sliding systems consisting of solid object on a solid substrate under dry condition, the friction force does not depend on the apparent contact area and is proportional to the loading force. This behaviour is called Amontons' law and indicates that the friction coefficient, or the ratio of the friction force to the loading force, is constant. Here, however, using numerical and analytical methods, we show that Amontons' law breaks down systematically under certain conditions for an elastic object experiencing a friction force that locally obeys Amontons' law. The macroscopic static friction coefficient, which corresponds to the onset of bulk sliding of the object, decreases as pressure or system length increases. This decrease results from precursor slips before the onset of bulk sliding, and is consistent with the results of certain previous experiments. The mechanisms for these behaviours are clarified. These results will provide new insight into controlling friction. PMID:23545778
Landslide tsunami hazard in New South Wales, Australia: novel observations from 3D modelling
NASA Astrophysics Data System (ADS)
Power, Hannah; Clarke, Samantha; Hubble, Tom
2015-04-01
This paper examines the potential of tsunami inundation generated from two case study sites of submarine mass failures on the New South Wales coast of Australia. Two submarine mass failure events are investigated: the Bulli Slide and the Shovel Slide. Both slides are located approximately 65 km southeast of Sydney and 60 km east of the township of Wollongong. The Bulli Slide (~20 km3) and the Shovel Slide (7.97 km3) correspond to the two largest identified erosional surface submarine landslides scars of the NSW continental margin (Glenn et al. 2008; Clarke 2014) and represent examples of large to very large submarine landslide scars. The Shovel Slide is a moderately thick (80-165 m), moderately wide to wide (4.4 km) slide, and is located in 880 m water depth; and the Bulli Slide is an extremely thick (200-425 m), very wide (8.9 km) slide, and is located in 1500 m water depth. Previous work on the east Australian margin (Clarke et al., 2014) and elsewhere (Harbitz et al., 2013) suggests that submarine landslides similar to the Bulli Slide or the Shovel Slide are volumetrically large enough and occur at shallow enough water depths (400-2500 m) to generate substantial tsunamis that could cause widespread damage on the east Australian coast and threaten coastal communities (Burbidge et al. 2008; Clarke 2014; Talukder and Volker 2014). Currently, the tsunamogenic potential of these two slides has only been investigated using 2D modelling (Clarke 2014) and to date it has been difficult to establish the onshore tsunami surge characteristics for the submarine landslides with certainty. To address this knowledge gap, the forecast inundation as a result of these two mass failure events was investigated using a three-dimensional model (ANUGA) that predicts water flow resulting from natural hazard events such as tsunami (Nielsen et al., 2005). The ANUGA model solves the two-dimensional shallow water wave equations and accurately models the process of wetting and drying thus making it ideal for simulating inundation due to tsunami. The model generates a surface wave profile based on the dimensions of the submarine mass failure event using the method of Ward et al. (2005). Inundation maps are shown for these two slides and sensitivity analysis is conducted to identify the characteristics of the slides that are most influential on inundation areas and depths.
Energy monitoring and analysis during deformation of bedded-sandstone: use of acoustic emission.
Wasantha, P L P; Ranjith, P G; Shao, S S
2014-01-01
This paper investigates the mechanical behaviour and energy releasing characteristics of bedded-sandstone with bedding layers in different orientations, under uniaxial compression. Cylindrical sandstone specimens (54 mm diameter and 108 mm height) with bedding layers inclined at angles of 10°, 20°, 35°, 55°, and 83° to the minor principal stress direction, were produced to perform a series of Uniaxial Compressive Strength (UCS) tests. One of the two identical sample sets was fully-saturated with water before testing and the other set was tested under dry conditions. An acoustic emission system was employed in all the testing to monitor the acoustic energy release during the whole deformation process of specimens. From the test results, the critical joint orientation was observed as 55° for both dry and saturated samples and the peak-strength losses due to water were 15.56%, 20.06%, 13.5%, 13.2%, and 13.52% for the bedding orientations 10°, 20°, 35°, 55°, and 83°, respectively. The failure mechanisms for the specimens with bedding layers in 10°, 20° orientations showed splitting type failure, while the specimens with bedding layers in 55°, 83° orientations were failed by sliding along a weaker bedding layer. The failure mechanism for the specimens with bedding layers in 35° orientation showed a mixed failure mode of both splitting and sliding types. Analysis of the acoustic energy, captured from the acoustic emission detection system, revealed that the acoustic energy release is considerably higher in dry specimens than that of the saturated specimens at any bedding orientation. In addition, higher energy release was observed for specimens with bedding layers oriented in shallow angles (which were undergoing splitting type failures), whereas specimens with steeply oriented bedding layers (which were undergoing sliding type failures) showed a comparatively less energy release under both dry and saturated conditions. Moreover, a considerable amount of energy dissipation before the ultimate failure was observed for specimens with bedding layers oriented in shallow angles under both dry and saturated conditions. These results confirm that when rock having bedding layers inclined in shallow angles the failures could be more violent and devastative than the failures of rock with steeply oriented bedding layers. Copyright © 2013 Elsevier B.V. All rights reserved.
Effects of soil-engineering properties on the failure mode of shallow landslides
McKenna, Jonathan Peter; Santi, Paul Michael; Amblard, Xavier; Negri, Jacquelyn
2012-01-01
Some landslides mobilize into flows, while others slide and deposit material immediately down slope. An index based on initial dry density and fine-grained content of soil predicted failure mode of 96 landslide initiation sites in Oregon and Colorado with 79% accuracy. These material properties can be used to identify potential sources for debris flows and for slides. Field data suggest that loose soils can evolve from dense soils that dilate upon shearing. The method presented herein to predict failure mode is most applicable for shallow (depth 8), with few to moderate fines (fine-grained content <18%), and with liquid limits <40.
Single-walled carbon nanotube electromechanical switching behavior with shoulder slip
NASA Astrophysics Data System (ADS)
Ryan, Peter; Wu, Yu-Chiao; Somu, Sivasubramanian; Adams, George; McGruer, Nicol
2011-04-01
Several electromechanical devices, each consisting of a small bundle of single-walled carbon nanotubes suspended over an actuation electrode, have been fabricated and operated electrically. The nanotubes are assembled on the electrodes using dielectrophoresis, a potential high-rate nanomanufacturing process. A large decrease in the threshold voltage was seen after the first actuation. This is a result of the nanotubes sliding inward on their supports as they are pulled down toward the actuation electrode, leaving slack in the nanotube bundle for subsequent actuations. The electrical measurements agree well with an electromechanical model that uses a literature-reported value of the shear stress between the nanotubes and the SiO2 shoulders. Electrical measurements were performed in dry nitrogen as a large build-up of contamination was seen when the measurements were performed in lab air. We present measurements as well as a detailed mechanics model that support the interpretation of the data.
3D finite element modeling of sliding wear
NASA Astrophysics Data System (ADS)
Buentello Hernandez, Rodolfo G.
Wear is defined as "the removal of material volume through some mechanical process between two surfaces". There are many mechanical situations that can induce wear and each can involve many wear mechanisms. This research focuses on the mechanical wear due to dry sliding between two surfaces. Currently there is a need to identify and compare materials that would endure sliding wear under severe conditions such as high velocities. The high costs associated with the field experimentation of systems subject to high-speed sliding, has prevented the collection of the necessary data required to fully characterize this phenomena. Simulating wear through Finite Elements (FE) would enable its prediction under different scenarios and would reduce experimentation costs. In the aerospace, automotive and weapon industries such a model can aid in material selection, design and/or testing of systems subjected to wear in bearings, gears, brakes, gun barrels, slippers, locomotive wheels, or even rocket test tracks. The 3D wear model presented in this dissertation allows one to reasonably predict high-speed sliding mechanical wear between two materials. The model predictions are reasonable, when compared against those measured on a sled slipper traveling over the Holloman High Speed Tests Track. This slipper traveled a distance of 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s.
Y.E.S. International Entomology Resource Guide. Second Edition. Special Publication No. 2.
ERIC Educational Resources Information Center
Dunn, Gary A., Comp.
This resource guide is designed to provide Young Entomologists' Society (Y.E.S.) members and other interested entomologists with information on people and companies that sell entomological equipment, supplies, services, preserved and dried specimens, livestock, books, publications, slides and other visuals, gift or novelty items, and…
Olivine Friction at the Base of the Seismogenic Zone
NASA Astrophysics Data System (ADS)
Boettcher, M. S.; Hirth, G.; Evans, B.
2003-12-01
The frictional properties at the base of the seismogenic zone in oceanic lithosphere are fundamental to our understanding of oceanic earthquake processes. While the composition of the oceanic lithosphere is probably the simplest and most well constrained of any seismogenic region on Earth, few data on its frictional properties exist. We are investigating the strength and sliding stability of olivine aggregates at temperature and effective pressure conditions close to those at the base of the seismogenic zone on a typical transform fault. We have conducted triaxial compression tests on dry olivine powder (38-60 \\ μ m particles) at effective pressures of P{eff} = P{c} - P{f} = 50, \\ 200, \\ & \\ 300 MPa using argon as a pore fluid medium, temperatures of T = 800o{C} \\ & \\ 1000o{C}, and strain rates of ˙ {ɛ } = 3 x 10-5 \\ & \\ 3 x 10-4. For all experiments, strain became localized on faults and strain-rate steps showed velocity-weakening behavior. Stick-slip events were observed at all temperatures up to 1000oC, with a greater tendency towards instability (i.e. more stick-slip events) at the higher strain rate. By contrast, previous laboratory work by Stesky et al. (1974) found stable sliding for olivine at temperatures above 200oC. Our experiments are consistent with seismic data, which find that earthquake hypocenters regularly occur to temperatures well above 200oC, regularly to near the 600oC isotherm.
Benbouzid, Mohamed; Beltran, Brice; Amirat, Yassine; Yao, Gang; Han, Jingang; Mangel, Hervé
2014-05-01
This paper deals with the fault ride-through capability assessment of a doubly fed induction generator-based wind turbine using a high-order sliding mode control. Indeed, it has been recently suggested that sliding mode control is a solution of choice to the fault ride-through problem. In this context, this paper proposes a second-order sliding mode as an improved solution that handle the classical sliding mode chattering problem. Indeed, the main and attractive features of high-order sliding modes are robustness against external disturbances, the grids faults in particular, and chattering-free behavior (no extra mechanical stress on the wind turbine drive train). Simulations using the NREL FAST code on a 1.5-MW wind turbine are carried out to evaluate ride-through performance of the proposed high-order sliding mode control strategy in case of grid frequency variations and unbalanced voltage sags. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Particle interaction and rheological behavior of cement-based materials at micro- and macro-scales
NASA Astrophysics Data System (ADS)
Lomboy, Gilson Rescober
Rheology of cement based materials is controlled by the interactions at the particle level. The present study investigates the particle interactions and rheological properties of cement-based materials in the micro- and macro-scales. The cementitious materials studied are Portland cement (PC), fly ash (FA), ground granulated blast furnace slag (GGBFS) and densified silica fume (SF). At the micro-scale, aside from the forces on particles due to collisions, interactions of particles in a flowing system include the adhesion and friction. Adhesion is due to the attraction between materials and friction depends on the properties of the sliding surfaces. Atomic Force Microscopy (AFM) is used to measure the adhesion force and coefficient of friction. The adhesion force is measured by pull-off force measurements and is used to calculate Hamaker constants. The coefficient of friction is measured by increasing the deflection set-points on AFM probes with sliding particles, thereby increasing normal loads and friction force. AFM probes were commercial Si3N4 tips and cementitious particles attached to the tips of probe cantilevers. SF was not included in the micro-scale tests due to its limiting size when attaching it to the AFM probes. Other materials included in the tests were silica, calcite and mica, which were used for verification of the developed test method for the adhesion study. The AFM experiments were conducted in dry air and fluid environments at pH levels of 7, 8, 9, 11 and 13. The results in dry air indicate that the Hamaker constant of Class F FA can be similar to PC, but Class C FA can have a high Hamaker constant, also when in contact with other cementitious materials. The results in fluid environments showed low Hamaker constants for Class F fly ashes compared to PC and also showed high Hamaker constants for PC and Class C fly ash. The results for the friction test in dry air indicated that the coefficient of friction of PC is lower than fly ashes, which is attributed to the asperities present on the particle surface. At the macro-scale, flow of cementitious materials may be in its dry or wet state, during transport and handling or when it is used in concrete mixtures, respectively. Hence, the behavior of bulk cementitious materials in their dry state and wet form are studied. In the dry state, the compression, recompression and swell indices, and stiffness modulus of plain and blended cementitious materials are determined by confined uniaxial compression. The coefficients of friction of the bulk materials studied are determined by a direct shear test. The results indicate that shape of particles has a great influence on the compression and shear parameters. The indices for PC blends with FA do not change with FA replacement, while it increases with GGBFS replacement. Replacement with GGBFS slightly decreases coefficient of friction, while replacement with FA significantly decreases coefficient of friction. At low SF replacement, coefficient of friction decreases. In wet state, unary, binary, ternary and quaternary mixes with w/b of 0.35, 0.45 and 0.55 were tested for yield stress, viscosity and thixotropy. It is found that fly ash replacement lowers the rheological properties and replacement with GGBFS and SF increases rheological properties. The distinct element method (DEM) was employed to model particle interaction and bulk behavior. The AFM force curve measurement is simulated to validate the adhesion model in the DEM. The contact due to asperities was incorporated by considering the asperities as a percentage of the radius of the contacting particles. The results of the simulation matches the force-curve obtained from actual AFM experiments. The confined uniaxial compression test is simulated to verify the use of DEM to relate micro-scale properties to macros-scale behavior. The bulk stiffness from the physical experiments is matched in the DEM simulation. The particle stiffness and coefficient of friction are found to have a direct relation to bulk stiffness.
Second-order sliding mode control with experimental application.
Eker, Ilyas
2010-07-01
In this article, a second-order sliding mode control (2-SMC) is proposed for second-order uncertain plants using equivalent control approach to improve the performance of control systems. A Proportional + Integral + Derivative (PID) sliding surface is used for the sliding mode. The sliding mode control law is derived using direct Lyapunov stability approach and asymptotic stability is proved theoretically. The performance of the closed-loop system is analysed through an experimental application to an electromechanical plant to show the feasibility and effectiveness of the proposed second-order sliding mode control and factors involved in the design. The second-order plant parameters are experimentally determined using input-output measured data. The results of the experimental application are presented to make a quantitative comparison with the traditional (first-order) sliding mode control (SMC) and PID control. It is demonstrated that the proposed 2-SMC system improves the performance of the closed-loop system with better tracking specifications in the case of external disturbances, better behavior of the output and faster convergence of the sliding surface while maintaining the stability. 2010 ISA. Published by Elsevier Ltd. All rights reserved.
A rapid method for concentrating sedimentary organic matter for vitrinite reflectance analysis.
Barker, C.E.
1982-01-01
The tecnique discussed in this paper utilizes crushing, high-speed blending, and ultrasonic treatment to mechanically disaggregate rock and release the sedimentary organic matter (OM) in a suitable heavy liquid. This new method can provide freeze-dried concentrated OM in approximately 8 to 24 hours (longer time is necessary for removing carbonate). Under optimal conditions, it is possible to concentrate the OM and prepare a hardened epoxy microscope slide in about 24 hours. Subsequent grinding, polishing, and drying allows microscopic examination of the organic concentrate the next day.-from Author
Tuning the Slide-Roll Motion Mode of Carbon Nanotubes via Hydroxyl Groups
NASA Astrophysics Data System (ADS)
Li, Rui; Wang, Shiwei; Peng, Qing
2018-05-01
Controlling the motion of carbon nanotubes is critical in manipulating nanodevices, including nanorobots. Herein, we investigate the motion behavior of SWCNT (10,10) on Si substrate utilizing molecular dynamics simulations. We show that hydroxyl groups have sensitive effect on the carbon nanotube's motion mode. When the hydroxyl groups' ratio on carbon nanotube and silicon substrate surfaces is larger than 10 and 20%, respectively, the motion of carbon nanotube transforms from sliding to rolling. When the hydroxyl groups' ratio is smaller, the slide or roll mode can be controlled by the speed of carbon nanotube, which is ultimately determined by the competition between the interface potential energy and kinetic energy. The change of motion mode holds true for different carbon nanotubes with hydroxyl groups. The chirality has little effect on the motion behavior, as opposed to the diameter, attributed to the hydroxyl groups' ratio. Our study suggests a new route to control the motion behavior of carbon nanotube via hydroxyl groups.
Tuning the Slide-Roll Motion Mode of Carbon Nanotubes via Hydroxyl Groups.
Li, Rui; Wang, Shiwei; Peng, Qing
2018-05-08
Controlling the motion of carbon nanotubes is critical in manipulating nanodevices, including nanorobots. Herein, we investigate the motion behavior of SWCNT (10,10) on Si substrate utilizing molecular dynamics simulations. We show that hydroxyl groups have sensitive effect on the carbon nanotube's motion mode. When the hydroxyl groups' ratio on carbon nanotube and silicon substrate surfaces is larger than 10 and 20%, respectively, the motion of carbon nanotube transforms from sliding to rolling. When the hydroxyl groups' ratio is smaller, the slide or roll mode can be controlled by the speed of carbon nanotube, which is ultimately determined by the competition between the interface potential energy and kinetic energy. The change of motion mode holds true for different carbon nanotubes with hydroxyl groups. The chirality has little effect on the motion behavior, as opposed to the diameter, attributed to the hydroxyl groups' ratio. Our study suggests a new route to control the motion behavior of carbon nanotube via hydroxyl groups.
Friction testing of a new ligature
NASA Astrophysics Data System (ADS)
Mantel, Alison R.
Objective. To determine if American Orthodontics' (AO) new, experimental ligature demonstrates less friction in vitro when compared to four other ligatures on the market. Methods. Four brackets were mounted on a custom metal fixture allowing an 0.018-in stainless steel wire attached to an opposite fixture with one bracket to be passively centered in the bracket slot. The wire was ligated to the bracket using one of five types of ligatures including the low friction test ligatures (AO), conventional ligatures (AO), Sili-Ties(TM) Silicone Infused Ties (GAC), SynergyRTM Low-Friction Ligatures (RMO), and SuperSlick ligatures (TP Orthodontics). Resistance to sliding was measured over a 7 mm sliding distance using a universal testing machine (Instron) with a 50 Newton load cell and a crosshead speed of 5 mm/min. The initial resistance to sliding (static) was determined by the peak force needed to initiate movement and the kinetic resistance to sliding was taken as the force at 5 mm of wire/bracket sliding. Fifteen unique tests were run for each ligature group in both dry and wet (saliva soaked for 24 hours with one drop prior to testing) conditions. Results. In the dry state, the SuperSlick ligature demonstrated more static friction than all of the other ligatures, while SuperSlick and Sili-Ties demonstrated more kinetic friction than the AO conventional, AO experimental and Synergy ligatures. In the wet condition, SuperSlick and the AO experimental ligature demonstrated the least static friction, followed by the AO conventional and Sili-Ties. The most static friction was observed with the Synergy ligatures. In the wet condition, the SuperSlick, AO experimental and AO conventional exhibited less kinetic friction than the Sili-Ties and Synergy ligatures. Conclusions. AO's experimental ligature exhibits less friction in the wet state than conventional ligatures, Sili-Ties and Synergy and is comparable to the SuperSlick ligature. These preliminary results suggest that the AO experimental ligature and the SuperSlick ligature create less friction, but direct conclusions regarding in vivo performance cannot be made and randomized controlled clinical trials are needed to determine if these ligatures have clinical significance in treatment efficiency.
The Architecture and Frictional Properties of Faults in Shale
NASA Astrophysics Data System (ADS)
De Paola, N.; Imber, J.; Murray, R.; Holdsworth, R.
2015-12-01
The geometry of brittle fault zones in shale rocks, as well as their frictional properties at reservoir conditions, are still poorly understood. Nevertheless, these factors may control the very low recovery factors (25% for gas and 5% for oil) obtained during fracking operations. Extensional brittle fault zones (maximum displacement < 3 m) cut exhumed oil mature black shales in the Cleveland Basin (UK). Fault cores up to 50 cm wide accommodated most of the displacement, and are defined by a stair-step geometry. Their internal architecture is characterised by four distinct fault rock domains: foliated gouges; breccias; hydraulic breccias; and a slip zone up to 20 mm thick, composed of a fine-grained black gouge. Hydraulic breccias are located within dilational jogs with aperture of up to 20 cm. Brittle fracturing and cataclastic flow are the dominant deformation mechanisms in the fault core of shale faults. Velocity-step and slide-hold-slide experiments at sub-seismic slip rates (microns/s) were performed in a rotary shear apparatus under dry, water and brine-saturated conditions, for displacements of up to 46 cm. Both the protolith shale and the slip zone black gouge display shear localization, velocity strengthening behaviour and negative healing rates, suggesting that slow, stable sliding faulting should occur within the protolith rocks and slip zone gouges. Experiments at seismic speed (1.3 m/s), performed on the same materials under dry conditions, show that after initial friction values of 0.5-0.55, friction decreases to steady-state values of 0.1-0.15 within the first 10 mm of slip. Contrastingly, water/brine saturated gouge mixtures, exhibit almost instantaneous attainment of very low steady-state sliding friction (0.1), suggesting that seismic ruptures may efficiently propagate in the slip zone of fluid-saturated shale faults. Stable sliding in faults in shale can cause slow fault/fracture propagation, affecting the rate at which new fracture areas are created and, hence, limiting oil and gas production during reservoir stimulation. However, fluid saturated conditions can favour seismic slip propagation, with fast and efficient creation of new fracture areas. These processes are very effective at dilational jogs, where fluid circulation may be enhanced, facilitating oil and gas production.
Arif, Taib; Colas, Guillaume; Filleter, Tobin
2018-06-12
In this work, the effect of humidity and water intercalation on the friction and wear behavior of few-layers of graphene and graphene oxide (GO) was studied using friction force microscopy. Thickness measurements demonstrated significant water intercalation within GO affecting its surface topography (roughness and protrusions), whereas negligible water intercalation of graphene was observed. It was found that water intercalation in GO contributed to wearing of layers at a relative humidity as low as ~30%. The influence of surface wettability and water adsorption was also studied by comparing the sliding behavior of SiO2/GO, SiO2/Graphene, and SiO2/SiO2 interfaces. Friction for the SiO2/GO interface increased with relative humidity due to water intercalation and condensation of water. In contrast, it was observed that adsorption of water molecules lubricated the SiO2/SiO2 interface due to easy shearing of water on the hydrophobic surface, particularly once the adsorbed water layers had transitioned from "ice-like water" to "liquid-like water" structures. Lastly, an opposite friction trend was observed for the graphene/SiO2 interface with water molecules failing to lubricate the interface as compared to the dry graphene/SiO2 contact.
NASA Astrophysics Data System (ADS)
Heilig, Sebastian; Ramezani, Maziar; Neitzert, Thomas; Liewald, Mathias
2018-03-01
Ti-6Al-2Sn-4Zr-2Mo (Ti-6-2-4-2) is a typical near-α titanium alloy developed for high-temperature applications. It offers numerous enhanced properties like an outstanding strength-to-weight ratio, a low Young's modulus and exceptional creep and corrosion resistance. On the other hand, titanium alloys are known for their weak resistance to wear. Ti-6-2-4-2 is mainly applied in aero engine component parts, which are exposed to temperatures up to 565 °C. Through an increasing demand on efficiency, engine components are exposed to higher combustion pressures and temperatures. Elevated temperature tribology tests were conducted on a pin-on-disk tribometer equipped with a heating chamber. The tests were carried out under dry conditions with a constant sliding distance of 600 m with a speed of 0.16 m/s at the ball point. The sliding partner was AISI E52100 steel ball with the hardness of 58HRC. The varied input variables are normal load and temperature. It can be concluded that the coefficient of friction (CoF) increases with increasing temperature, while the wear rate decreases to its minimum at 600 °C due to increasing adhesion and oxidation mechanisms. Wear track observations using a scanning electron microscope (SEM) including energy-dispersive x-ray spectroscopy (EDS) were used to determine the occurring wear mechanisms.
Pimentel, Roberta Ferreira; de Oliveira, Roberto Sotto Maior Fortes; Chaves, Maria das Graças Afonso Miranda; Elias, Carlos Nelson; Gravina, Marco Abdo
2013-01-01
To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.
NASA Astrophysics Data System (ADS)
Dorn, Ronald I.
2014-10-01
In order to respond to the general paucity of information on the chronology of ubiquitous small rock falls and slides that litter the slopes of desert mountain ranges, a case study in the Sonoran Desert reveals new insight into the desert geomorphology of mountain slopes. Rock falls and rock slides in the McDowell Mountains that abut metropolitan Phoenix, USA, fall in three chronometric groupings dated by conventional radiocarbon and rock varnish microlamination methods. First, the oldest events are > 74 ka and take the form of stable colluvial boulder fields - positive relief features that are tens of meters long and a few meters wide. Second, randomly sampled slides and falls of various sizes and positions wasted during wetter periods of the terminal Pleistocene and Holocene. Third, an anomalous clustering of slides and falls occurred during the late Medieval Warm Period (Medieval Climatic Anomaly) when an extreme storm was a possible but unlikely trigger. One speculative hypothesis for the cluster of Medieval Warm Period events is that a small to moderate sized earthquake shook heavily shattered bedrock - close to failure - just enough to cause a spate of rock falls and slides. A second speculative hypothesis is that this dry period enhanced physical weathering processes such as dirt cracking. However, the reasons for the recent clustering of rock falls remain enigmatic. While the temporal distribution of slides and falls suggests a minimal hazard potential for homes and roads on the margins of the McDowell Mountains, this finding may not necessary match other desert ranges in metropolitan Phoenix or mountains with different rock types and structures that abut other arid urban centers.
Friction law and hysteresis in granular materials
Wyart, M.
2017-01-01
The macroscopic friction of particulate materials often weakens as the flow rate is increased, leading to potentially disastrous intermittent phenomena including earthquakes and landslides. We theoretically and numerically study this phenomenon in simple granular materials. We show that velocity weakening, corresponding to a nonmonotonic behavior in the friction law, μ(I), is present even if the dynamic and static microscopic friction coefficients are identical, but disappears for softer particles. We argue that this instability is induced by endogenous acoustic noise, which tends to make contacts slide, leading to faster flow and increased noise. We show that soft spots, or excitable regions in the materials, correspond to rolling contacts that are about to slide, whose density is described by a nontrivial exponent θs. We build a microscopic theory for the nonmonotonicity of μ(I), which also predicts the scaling behavior of acoustic noise, the fraction of sliding contacts χ, and the sliding velocity, in terms of θs. Surprisingly, these quantities have no limit when particles become infinitely hard, as confirmed numerically. Our analysis rationalizes previously unexplained observations and makes experimentally testable predictions. PMID:28811373
Friction law and hysteresis in granular materials
NASA Astrophysics Data System (ADS)
DeGiuli, E.; Wyart, M.
2017-08-01
The macroscopic friction of particulate materials often weakens as the flow rate is increased, leading to potentially disastrous intermittent phenomena including earthquakes and landslides. We theoretically and numerically study this phenomenon in simple granular materials. We show that velocity weakening, corresponding to a nonmonotonic behavior in the friction law, μ(I), is present even if the dynamic and static microscopic friction coefficients are identical, but disappears for softer particles. We argue that this instability is induced by endogenous acoustic noise, which tends to make contacts slide, leading to faster flow and increased noise. We show that soft spots, or excitable regions in the materials, correspond to rolling contacts that are about to slide, whose density is described by a nontrivial exponent θs. We build a microscopic theory for the nonmonotonicity of μ(I), which also predicts the scaling behavior of acoustic noise, the fraction of sliding contacts χ, and the sliding velocity, in terms of θs. Surprisingly, these quantities have no limit when particles become infinitely hard, as confirmed numerically. Our analysis rationalizes previously unexplained observations and makes experimentally testable predictions.
Fabrication of high quality cDNA microarray using a small amount of cDNA.
Park, Chan Hee; Jeong, Ha Jin; Jung, Jae Jun; Lee, Gui Yeon; Kim, Sang-Chul; Kim, Tae Soo; Yang, Sang Hwa; Chung, Hyun Cheol; Rha, Sun Young
2004-05-01
DNA microarray technology has become an essential part of biological research. It enables the genome-scale analysis of gene expression in various types of model systems. Manufacturing high quality cDNA microarrays of microdeposition type depends on some key factors including a printing device, spotting pins, glass slides, spotting solution, and humidity during spotting. UsingEthe Microgrid II TAS model printing device, this study defined the optimal conditions for producing high density, high quality cDNA microarrays with the least amount of cDNA product. It was observed that aminosilane-modified slides were superior to other types of surface modified-slides. A humidity of 30+/-3% in a closed environment and the overnight drying of the spotted slides gave the best conditions for arraying. In addition, the cDNA dissolved in 30% DMSO gave the optimal conditions for spotting compared to the 1X ArrayIt, 3X SSC and 50% DMSO. Lastly, cDNA in the concentration range of 100-300 ng/ micro l was determined to be best for arraying and post-processing. Currently, the printing system in this study yields reproducible 9000 spots with a spot size 150 mm diameter, and a 200 nm spot spacing.
Nanocomposite tribological coatings with "chameleon" surface adaptation
NASA Astrophysics Data System (ADS)
Voevodin, A. A.; Fitz, T. A.; Hu, J. J.; Zabinski, J. S.
2002-07-01
Nanocomposite tribological coatings were designed to respond to changing environmental conditions by self-adjustment of their surface properties to maintain good tribological performance in any environment. These smart coatings have been dubbed "chameleon" because, analogous to a chameleon changing its skin color to avoid predators, the coating changes its "skin" chemistry and structure to avoid wear. The concept was originally developed using WC, diamondlike carbon, and WS2 material combination for adaptation to a humid/dry environment cycling. In order to address temperature variation, nanocomposite coatings made of yttria-stabilized zirconia (YSZ) in a gold matrix were developed with encapsulated nanosized reservoirs of MoS2 and diamondlike carbon (DLC). Coatings were produced using a combination of laser ablation and magnetron sputtering. They were characterized by x-ray photoelectron spectroscopy, x-ray diffraction, transmission electron microscopy, x-ray energy dispersive spectroscopy, and micro-Raman spectroscopy. Results were correlated with mechanical and tribological characterization. Coating hardness was evaluated using nanoindentation, while coating adhesion and toughness were estimated using scratch and Vickers indentation tests. Friction and wear endurance measurements of YSZ/Au/MoS2/DLC coatings against steel and Si3N4 balls were performed at room temperature in controlled humidity air, dry nitrogen, and vacuum environments, as well as at 500 degC in air. Depending on the environment, coating friction surface changed its chemistry and structure between (i) graphitic carbon for sliding in humid air [coating friction coefficients (c.o.f. 0.10-0.15)], (ii) hexagonal MoS2 for sliding in dry N2 and vacuum (c.o.f. 0.02-0.05), and (iii) metallic Au for sliding in air at 500 degC (c.o.f. 0.10-0.20). The unique coating skin adaptation realized with YSZ/Au/MoS2/DLC and WC/DLC/WS composites proves a universal applicability of the chameleon design concept. copyright 2002 American Vacuum Society.
The effect of normal load on polytetrafluoroethylene tribology.
Barry, Peter R; Chiu, Patrick Y; Perry, Scott S; Sawyer, W Gregory; Phillpot, Simon R; Sinnott, Susan B
2009-04-08
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
A rolling-sliding bench test for investigating rear axle lubrication
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.; ...
2018-02-07
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
A rolling-sliding bench test for investigating rear axle lubrication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stump, Benjamin C.; Zhou, Yan; Viola, Michael B.
An automotive rear axle is composed of a set of hypoid gears, whose contact surfaces experience a complex combination of rolling contact fatigue damage and sliding wear. Full-scale rear axle dynamometer tests are used in the industry for efficiency and durability assessment. Here, this study developed a bench-scale rolling-sliding test protocol by simulating the contact pressure, oil temperature, and lubrication regime experienced in a dynamometer duty cycle test. Initial bench results have demonstrated the ability of generating both rolling contact-induced micropitting and sliding wear and the feasibility of investigating the impact of slide-to-roll ratio, surface roughness, test duration, and oilmore » temperature on the friction behavior, vibration noise, and surface damage. Finally, this bench test will allow studying candidate rear axle lubricants and materials under relevant conditions.« less
The effect of normal load on polytetrafluoroethylene tribology
NASA Astrophysics Data System (ADS)
Barry, Peter R.; Chiu, Patrick Y.; Perry, Scott S.; Sawyer, W. Gregory; Phillpot, Simon R.; Sinnott, Susan B.
2009-04-01
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
Development and Sliding Wear Response of Epoxy Composites Filled with Coal Mine Overburden Material
NASA Astrophysics Data System (ADS)
Das, Prithika; Satapathy, Alok; Mishra, M. K.
2018-03-01
The paper reports on development and characterization of epoxy based composites filled with micro-sized mine overburden material. Coal mine overburden material is typically highly heterogeneous and is considered as waste material. For excavating each ton of coal, roughly 5 tons of overburden materials are removed and is dumped nearby occupying large space. Gainful utilization of this waste is a major challenge. In the present work, this material is used as filler materials in making a new class of epoxy matrix composites. Composites with different weight proportions of fillers (0, 10, 20, 30 and 40) wt. % are prepared by hand layup technique. Compression tests are performed as per corresponding ASTM standards to assess the compressive strength of these composites. Further, dry sliding tests are performed following ASTM G99 standards using a pin on disk machine. A design of experiment approach based on Taguchi’s L16 orthogonal arrays is adopted. Tests are performed at different sliding velocities for multiple sliding distances under varying normal loads. Specific wear rates of the composites under different test conditions are obtained. The analysis of the test results revealed that the filler content and the sliding velocity are the most predominant control factors affecting the wear rate. This work thus, opens up a new avenue for the value added utilization of coal mine overburden material.
Friction and wear behavior of graphite fiber reinforced polymide composites
NASA Technical Reports Server (NTRS)
Fusaro, R. L.; Sliney, H. E.
1977-01-01
The friction and wear rate characteristics of 50/50 (weight percent) graphite fiber polyimide composites were studied by sliding metallic hemispherically tipped riders against disks made from the composites. Two different polyimides and two different graphite fibers were evaluated. Also studied were such variables as the effect of moisture in an air atmosphere; the effect of temperature; and the effect of different sliding speeds. In general, wear to the the metallic riders was negligible, and composite wear increased at a constant rate as a function of number of sliding cycles.
NASA Astrophysics Data System (ADS)
Dhanalakshmi, S.; Mohanasundararaju, N.; Venkatakrishnan, P. G.; Karthik, V.
2018-02-01
The present study deals with investigations relating to dry sliding wear behaviour of the Al 7075 alloy, reinforced with Al2O3 and B4C. The hybrid composites are produced through Liquid Metallurgy route - Stir casting method. The amount of Al2O3 particles is varied as 3, 6, 9, 12 and 15 wt% and the amount of B4C is kept constant as 3wt%. Experiments were conducted based on the plan of experiments generated through Taguchi’s technique. A L27 Orthogonal array was selected for analysis of the data. The investigation is to find the effect of applied load, sliding speed and sliding distance on wear rate and Coefficient of Friction (COF) of the hybrid Al7075- Al2O3-B4C composite and to determine the optimal parameters for obtaining minimum wear rate. The samples were examined using scanning electronic microscopy after wear testing and analyzed.
NASA Astrophysics Data System (ADS)
Olaru, D.; Balan, M. R.; Tufescu, A.
2016-08-01
The authors investigated analytically and experimentally the friction torque in a modified thrust ball bearing operating at very low axial load in dry conditions by using only three balls and a cage. The experiments were conducted by using spin-down methodology. The results evidenced the influence of the sliding friction between the cage and the balls on the total friction torque. It was concluded that at very low loads the friction between cage and balls in a thrust ball bearing has an important contribution on total friction torque.
Terrain analysis of the racetrack basin and the sliding rocks of Death Valley
Messina, P.; Stoffer, P.
2000-01-01
The Racetrack Playa's unusual surface features known as sliding rocks have been the subject of an ongoing debate and several mapping projects for half a century, although the causative mechanism remains unresolved. Clasts ranging in volume from large pebbles to medium boulders have, unwitnessed, maneuvered around the nearly flat dry lake over considerable distances. The controversy has persisted partly because eyewitness accounts of the phenomenon continue to be lacking, and the earlier mapping missions were limited in method and geographic range. In July 1996, we generated the first complete map of all observed sliding rock trails by submeter differential Global Positioning System (DGPS) mapping technology. The resulting map shows 162 sliding rocks and associated trails to an accuracy of approximately 30 cm. Although anemometer data are not available in the Racetrack wilderness, wind is clearly a catalyst for sliding rock activity; an inferred wind rose was constructed from DGPS trail segment data. When the entire trail network is examined in plan, some patterns emerge, although other (perhaps expected relations) remain elusive: terrain analysis of the surrounding topography demonstrates that the length and morphology of trails are more closely related to where rocks rested at the onset of motion than to any physical attribute of the rocks themselves. Follow-up surveys in May 1998, May 1999, August 1999, and November 1999 revealed little modification of the July, 1996 sliding rock configuration. Only four rocks were repositioned during the El Nino winter of 1997-1998, suggesting that activity may not be restricted to winter storms. (C) 2000 Elsevier Science B.V. All rights reserved.
Mechanical Properties and Tribological Behavior of In Situ NbC/Fe Surface Composites
NASA Astrophysics Data System (ADS)
Cai, Xiaolong; Zhong, Lisheng; Xu, Yunhua
2017-01-01
The mechanical properties and tribological behavior of the niobium carbide (NbC)-reinforced gray cast iron surface composites prepared by in situ synthesis have been investigated. Composites are comprised of a thin compound layer and followed by a deep diffusion zone on the surface of gray cast iron. The graded distributions of the hardness and elastic modulus along the depth direction of the cross section of composites form in the ranges of 6.5-20.1 and 159.3-411.2 GPa, respectively. Meanwhile, dry wear tests for composites were implemented on pin-on-disk equipment at sliding speed of 14.7 × 10-2 m/s and under 5 or 20 N, respectively. The result indicates that tribological performances of composites are considerably dependent on the volume fraction and the grain size of the NbC as well as the mechanical properties of the matrices in different areas. The surface compound layer presents the lowest coefficient of friction and wear rate, and exhibits the highest wear resistance, in comparison with diffusion zone and substrate. Furthermore, the worn morphologies observed reveal the dominant wear mechanism is abrasive wear feature in compound layer and diffusion zone.
Effects of gypsy moth infestation on aesthetic preferences and behavior intentions
Samuel M. Brock; Steve Hollenhorst; Wayne Freimund
1991-01-01
Using the Scenic Beauty Estimator (SBE) approach, within-stand color photographs were taken of 27 forested sites representative of the Central Appalachian Plateau. These sites had been repeatedly infested by gypsy moth (Lymantria dispar) (GM) to varying degrees since 1985, with resulting tree mortality from 6% - 97%. Eighty-one slides (3 slides/site...
Wear behavior of electroless Ni-P-W coating under lubricated condition - a Taguchi based approach
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Arkadeb; Duari, Santanu; Barman, Tapan Kumar; Sahoo, Prasanta
2016-09-01
The present study aims to investigate the tribological behavior of electroless Ni-P-W coating under engine oil lubricated condition to ascertain its suitability in automotive applications. Coating is deposited onto mild steel specimens by the electroless method. The experiments are carried out on a pin - on - disc type tribo tester under lubrication. Three tribotesting parameters namely the applied normal load, sliding speed and sliding duration are varied at their three levels and their effects on the wear depth of the deposits are studied. The experiments are carried out based on the combinations available in Taguchi's L27 orthogonal array (OA). Optimization of the tribo-testing parameters is carried out using Taguchi's S/N ratio method to minimize the wear depth. Analysis of variance carried out at a confidence level of 99% indicates that the sliding speed is the most significant parameter in controlling the wear behavior of the deposits. Coating characterization is done using scanning electron microscope, energy dispersive X-ray analysis and X-ray diffraction techniques. It is seen that the wear mechanism under lubricated condition is abrasive in nature.
Change in Frictional Behavior during Olivine Serpentinization
NASA Astrophysics Data System (ADS)
Xing, T.; Zhu, W.; French, M. E.; Belzer, B.
2017-12-01
Hydration of mantle peridotites (serpentinization) is pervasive at plate boundaries. It is widely accepted that serpentinization is intrinsically linked to hydromechanical processes within the sub-seafloor, where the interplay between cracking, fluid supply and chemical reactions is responsible for a spectrum of fault slip, from earthquake swarms at the transform faults, to slow slip events at the subduction zone. Previous studies demonstrate that serpentine minerals can either promote slip or creep depend on many factors that include sliding velocity, temperature, pressure, interstitial fluids, etc. One missing link from the experimental investigation of serpentine to observations of tectonic faults is the extent of alteration necessary for changing the frictional behaviors. We quantify changes in frictional behavior due to serpentinization by conducting experiments after in-situ serpentinization of olivine gouge. In the sample configuration a layer of powder is sandwiched between porous sandstone blocks with 35° saw-cut surface. The starting material of fine-grained (63 120 µm) olivine powder is reacted with deionized water for 72 hours at 150°C before loading starts. Under the conventional triaxial configuration, the sample is stressed until sliding occurs within the gouge. A series of velocity-steps is then performed to measure the response of friction coefficient to variations of sliding velocity from which the rate-and-state parameters are deduced. For comparison, we measured the frictional behavior of unaltered olivine and pure serpentine gouges.Our results confirm that serpentinization causes reduced frictional strength and velocity weakening. In unaltered olivine gouge, an increase in frictional resistance with increasing sliding velocity is observed, whereas the serpentinized olivine and serpentine gouges favor velocity weakening behaviors at the same conditions. Furthermore, we observed that high pore pressures cause velocity weakening in olivine but velocity strengthening in serpentine. The alteration of frictional behavior is considerable even though the fraction of altered olivine is miniscule. Contrasting frictional responses between olivine and serpentine gouges in response to high pore pressure shed some light on faulting in ultramafic chemical environments.
Mujawar, Liyakat Hamid; Maan, Abid Aslam; Khan, Muhammad Kashif Iqbal; Norde, Willem; van Amerongen, Aart
2013-04-02
The main focus of our research was to study the distribution of inkjet printed biomolecules in porous nitrocellulose membrane pads of different brands. We produced microarrays of fluorophore-labeled IgG and bovine serum albumin (BSA) on FAST, Unisart, and Oncyte-Avid slides and compared the spot morphology of the inkjet printed biomolecules. The distribution of these biomolecules within the spot embedded in the nitrocellulose membrane was analyzed by confocal laser scanning microscopy in the "Z" stack mode. By applying a "concentric ring" format, the distribution profile of the fluorescence intensity in each horizontal slice was measured and represented in a graphical color-coded way. Furthermore, a one-step diagnostic antibody assay was performed with a primary antibody, double-labeled amplicons, and fluorophore-labeled streptavidin in order to study the functionality and distribution of the immune complex in the nitrocellulose membrane slides. Under the conditions applied, the spot morphology and distribution of the primary labeled biomolecules was nonhomogenous and doughnut-like on the FAST and Unisart nitrocellulose slides, whereas a better spot morphology with more homogeneously distributed biomolecules was observed on the Oncyte-Avid slide. Similar morphologies and distribution patterns were observed when the diagnostic one-step nucleic acid microarray immunoassay was performed on these nitrocellulose slides. We also investigated possible reasons for the differences in the observed spot morphology by monitoring the dynamic behavior of a liquid droplet on and in these nitrocellulose slides. Using high speed cameras, we analyzed the wettability and fluid flow dynamics of a droplet on the various nitrocellulose substrates. The spreading of the liquid droplet was comparable for the FAST and Unisart slides but different, i.e., slower, for the Oncyte-Avid slide. The results of the spreading of the droplet and the penetration behavior of the liquid in the nitrocellulose membrane may (partly) explain the distribution of the biomolecules in the different slides. To our knowledge, this is the first time that fluid dynamics in diagnostic membranes have been analyzed by the use of high-speed cameras.
NASA Astrophysics Data System (ADS)
Barry, Peter R.
Polytetrafluoroethylene (PTFE) is a polymer that has been widely exploited commercially as a result of its low friction, 'non-stick' properties. The polymer has found usage as 'non-stick,' chemically resistant coatings for bearings, valves, rollers and pipe linings with applications in industries ranging from food and chemical processing to construction, automotive and aerospace. The major drawback of PTFE in low friction applications involves its excessive wear rate. For decades, scientists and engineers have sought to improve the polymer's wear resistance while maintaining its low sliding friction by reinforcing the polymer matrix with a host of filler materials ranging from fibril to particulate. In this study, a different approach is taken in which the atomic scale phenomena between two crystalline PTFE surfaces in sliding contact are examined. The goal is to obtain atomic-level insights into PTFE's low friction and high wear rate to aid in the designing of effective polymer based tribological composites for extreme condition applications. To accomplish this, several tribological conditions were varied. These included sliding direction of the two polymer surfaces with respect to their chain alignment, sliding velocity, degree of crystalline phase rigidity, interfacial contact pressure, sample temperature and the presence of fluorocarbon fluids between the two crystalline PTFE surfaces. From these studies, it was found that crystalline PTFE-PTFE sliding demonstrates friction anisotropy. Low friction and molecular wear was observed when sliding in the direction of the chain alignment with high friction and wear behavior dominating when sliding in a direction perpendicular to the chain alignment. For the range of cross-link density (average linear density of 6.2 to 11.1 A) and sliding rate (5 m/s to 20 m/s) explored, a significant change in friction behavior or wear mechanisms was not observed. Under conditions of increased normal load or low temperature however, the frictional force increased linearly. Additionally, the inclusion of fluorocarbon molecular fluids at the sliding interface between the two crystalline PTFE surfaces resulted in a significant decrease in both the friction and wear of the surfaces.
Failure mechanism of coated biomaterials under high impact-sliding contact stresses
NASA Astrophysics Data System (ADS)
Chen, Ying
This study uses a newly developed testing method--- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off.
Superlubric sliding of graphene nanoflakes on graphene.
Feng, Xiaofeng; Kwon, Sangku; Park, Jeong Young; Salmeron, Miquel
2013-02-26
The lubricating properties of graphite and graphene have been intensely studied by sliding a frictional force microscope tip against them to understand the origin of the observed low friction. In contrast, the relative motion of free graphene layers remains poorly understood. Here we report a study of the sliding behavior of graphene nanoflakes (GNFs) on a graphene surface. Using scanning tunneling microscopy, we found that the GNFs show facile translational and rotational motions between commensurate initial and final states at temperatures as low as 5 K. The motion is initiated by a tip-induced transition of the flakes from a commensurate to an incommensurate registry with the underlying graphene layer (the superlubric state), followed by rapid sliding until another commensurate position is reached. Counterintuitively, the average sliding distance of the flakes is larger at 5 K than at 77 K, indicating that thermal fluctuations are likely to trigger their transitions from superlubric back to commensurate ground states.
NASA Astrophysics Data System (ADS)
Belkin, P. N.; Kusmanov, S. A.; Dyakov, I. G.; Silkin, S. A.; Smirnov, A. A.
2017-05-01
In our previous studies, we have shown that anode plasma electrolytic saturation of titanium alloys with nitrogen and carbon can improve their tribological properties. Obtained structure containing oxide layer and solid solution of diffused element in titanium promotes the enhancement of running-in ability and the decrease in the wear rate in some special cases. In this paper, further investigations are reported regarding the tribological properties of alpha- and beta-titanium alloys in wear test against hardened steel (50 HRC) disk using pin-on-disk geometry and balls of Al2O3 (6.25 mm in diameter) or bearing steel (9.6 mm in diameter) with ball-on-plate one and normal load from 5 to 209 N. Reproducible results were obtained under testing samples treated by means of the plasma electrolytic nitriding (PEN) with the mechanical removal of the oxide layer. Friction coefficient of nitrided samples is 0.5-0.9 which is somewhat higher than that for untreated one (0.48-0.75) during dry sliding against Al2O3 ball. An increase in the sliding speed results in the polishing of nitrided samples and reduction of their wear rate by 60 times. This result is obtained for 5 min at 850 °C using PEN in electrolyte containing 5 wt.% ammonia and 10 wt.% ammonium chloride followed by quenching in solution. Optical microscope was employed to assist in the evaluation of the wear behavior. Sizes of wear tracks were measured by profilometer TR200.
Sæmundsson, Þorsteinn; Morino, Costanza; Helgason, Jón Kristinn; Conway, Susan J; Pétursson, Halldór G
2018-04-15
On the 20th September 2012, a large debris slide occurred in the Móafellshyrna Mountain in the Tröllaskagi peninsula, central north Iceland. Our work describes and discusses the relative importance of the three factors that may have contributed to the failure of the slope: intense precipitation, earthquake activity and thawing of ground ice. We use data from weather stations, seismometers, witness reports and field observations to examine these factors. The slide initiated after an unusually warm and dry summer followed by a month of heavy precipitation. Furthermore, the slide occurred after three seismic episodes, whose epicentres were located ~60km NNE of Móafellshyrna Mountain. The main source of material for the slide was ice-rich colluvium perched on a topographic bench. Blocks of ice-cemented colluvium slid and then broke off the frontal part of the talus slope, and the landslide also involved a component of debris slide, which mobilized around 312,000-480,000m 3 (as estimated from field data and aerial images of erosional morphologies). From our analysis we infer that intense precipitation and seismic activity prior to the slide are the main preparatory factors for the slide. The presence of ice-cemented blocks in the slide's deposits leads us to infer that deep thawing of ground ice was likely the final triggering factor. Ice-cemented blocks of debris have been observed in the deposits of two other recent landslides in northern Iceland, in the Torfufell Mountain and the Árnesfjall Mountain. This suggests that discontinuous mountain permafrost is degrading in Iceland, consistent with the decadal trend of increasing atmospheric temperature in Iceland. This study highlights a newly identified hazard in Iceland: landslides as a result of ground ice thaw. Knowledge of the detailed distribution of mountain permafrost in colluvium on the island is poorly constrained and should be a priority for future research in order to identify zones at risk from this hazard. Copyright © 2017 Elsevier B.V. All rights reserved.
Pollastro, R.M.
1982-01-01
Extremely well-oriented clay mineral mounts for X-ray diffraction analysis can be prepared quickly and without introducing segregation using the filter-membrane peel technique. Mounting problems encountered with smectite-rich samples can be resolved by using minimal sample and partial air-drying of the clay film before transfer to a glass slide. Samples containing small quantities of clay can produce useful oriented specimens if Teflon masks having more restrictive areas are inserted above the membrane filter during clay deposition. War]page and thermal shock of glass slides can be controlled by using a flat, porous, ceramic plate as a holding surface during heat treatments.
NASA Astrophysics Data System (ADS)
Suresha, B.; Harshavardhan, B.; Ravishankar, R.
2018-04-01
The present investigation deals with the fabrication and characterization of epoxy reinforced with bidirectional carbon fiber mat (CF/Ep) and filled with 2.5, 5 and 7.5 wt% potassium titanate whiskers (PTw) composites. The effect of PTw loading on hardness, tensile properties and dry sliding wear behaviour of CF/Ep composite were carefully investigated in expectation of providing valuable information for the application of hybrid CF/Ep composites. Results indicated that the incorporation of PTw actually improved the hardness, tensile strength and tensile modulus of CF/Ep composites. Meanwhile, the specific wear rate of CF/Ep filled by 5 wt % PTw reached to 6.3× 10-14 m3/N-m, which is 41% lower than that of CF/Ep composite at the same dry sliding condition. It also seen that the fiber and filler worked synergistically to enhance the wear resistance. Further, for all composites the friction coefficient increases with increase in load and sliding velocity. However, PTw reinforced CF/Ep exhibited considerably higher coefficient of friction compared to unfilled ones, while PTw filler loading of 5 wt% was effective in reducing the specific wear rate of CF/Ep composite. The carbon fiber carried the applied load between the contact surfaces and protected the epoxy from severe abrasion of the counterface. At the same time, the exposed PTw out of the epoxy matrix around the fiber inhibited the direct scraping between the fiber and counterface so that the fibers could be less directly impacted during the subsequent wear process and they were protected from severe damage.
Ferguson rock slide buries California State Highway near Yosemite National Park
Harp, Edwin L.; Reid, Mark E.; Godt, Jonathan W.; DeGraff, Jerome V.; Gallegos, Alan J.
2008-01-01
During spring 2006, talus from the toe area of a rock-block slide of about 800,000 m3 buried California State Highway 140, one of the main routes into heavily-visited Yosemite National Park, USA. Closure of the highway for 92 days caused business losses of about 4.8 million USD. The rock slide, composed of slate and phyllite, moved slowly downslope from April to June 2006, creating a fresh head scarp with 9-12 m of displacement. Movement of the main rock slide, a re-activation of an older slide, was triggered by an exceptionally wet spring 2006, following a very wet spring 2005. As of autumn 2006, most of the main slide appeared to be at rest, although rocks occasionally continued to fall from steep, fractured rock masses at the toe area of the slide. Future behavior of the slide is difficult to predict, but possible scenarios range from continued scattered rock fall to complete rapid failure of the entire mass. Although unlikely except under very destabilizing circumstances, a worst-case, rapid failure of the entire rock slide could extend across the Merced River, damming the river and creating a reservoir. As a temporary measure, traffic has been rerouted to the opposite side of the Merced River at about the same elevation as the buried section of Highway 140. A state-of-the-art monitoring system has been installed to detect movement in the steep talus slope, movement of the main slide mass, local strong ground motion from regional earthquakes, and sudden changes in stream levels, possibly indicating damming of the river by slide material.
Rheology of serpentinite in high-temperature and low-slip-velocity regime
NASA Astrophysics Data System (ADS)
Takahashi, M.; Uehara, S.; Mizoguchi, K.; Takeda, N.; Masuda, K.
2009-12-01
This study was designed to clarify the rheology of serpentinite experimentally, related both the sliding velocity and the temperature. The frictional behavior of serpentinite is of particular interest in the study of earthquake generation processes along subducting plates and transform faults. Previous studies [Reinen et al., 1991-93] revealed that the serpentinites indicated two-mechanical behaviors at velocity-step test: ‘state-variable dominated behavior’ at relatively higher velocity (0.1-10 μm/sec) and ‘flow-dominated behavior’ at lower velocity (less than 0.1 μm/sec). Such complexity on the frictional behavior could make it complicated to forecast on the slip acceleration process from the plate motion velocity to the earthquake. Even under the room-temperature condition, those multiple behavior could be observed, thus, serpentinite can be a model substance to present a new constitutive law at the brittle-ductile transition regime. We, therefore, focus to discuss the transient behaviors of serpentinite at the velocity-step test. We used a gas-medium, high-pressure, and high-temperature triaxial testing machine belonging to the National Institute of Advanced Industrial Science and Technology (AIST), Japan. Sliding deformation was applied on the thin zone of the serpentinite gouge (1.0 g of almost pure antigorite powder) sandwiched between two alumina blocks with oblique surfaces at 30° to the axis. All experiments were carried out under a set of constant conditions, 100 MPa of the confining pressure (Ar-gas) and 30 MPa of the pore pressure (distilled water). The temperature conditions were varied from the room-temperature to 500° C, and three sliding velocity-regimes were adopted: low (0.0115 - 0.115 μm/sec), middle (0.115 - 1.15 μm/sec) and high (1.15 - 11.5 μm/sec) velocity regimes. In each velocity regime, the sliding velocity was increased or decreased in a stepwise fashion, and then we observed the transient behaviors until it reached the new steady-state frictional strength. Most results showed velocity-strengthening and flow-like transient behavior. Roughly said, the degree of the velocity dependence became larger with increasing the temperature until 400° C, and became larger with decreasing the velocity. At the temperature condition from 300° C to 400° C, the increasing of the velocity dependence became conspicuous with decreasing the velocity. Moreover, just after the dehydration of the antigorite started (450° - 500° C), the friction behaved unstable sliding. The rheology of the serpentinite seemed to be “not simple” at this experimental conditions on this study.
NASA Astrophysics Data System (ADS)
Liu, Xiyao; Shi, Xiaoliang; Huang, Yuchun; Deng, Xiaobin; Lu, Guanchen; Yan, Zhao; Zhou, Hongyan; Xue, Bing
2018-03-01
M50 steel is widely applied to manufacture aircraft bearings where service lives are mainly determined by the friction and wear behaviors. The main purpose of this study is to investigate the tribological behaviors and wear mechanisms of M50-1.5 wt.% graphene composites (MGC) prepared by laser additive manufacturing (LAM) (MGC-LAM) sliding against Si3N4 ball from 25 to 550 °C at 18 N-0.2 m/s. XRD, EPMA, FESEM, and EDS mapping were conducted to understand the major mechanisms leading to the improvement in the sliding behavior of MGC-LAM. The results indicated that MGC-LAM showed the excellent friction and wear performance at 25-550 °C for the lower friction coefficient of 0.16-0.52 and less wear rate of 6.1-9.5 × 10-7 mm3 N-1 m-1. Especially at 350 °C, MGC-LAM obtained the best tribological performance (0.16, 6.1 × 10-7mm3 N-1 m-1). It was attributed to the dense coral-like microstructure, as well as the formed surface lubricating structure which is composed of the upper uniform lubricating film with massive graphene and the underneath compacted layer.
2012-07-01
of tissue stains Nissl substance, which is composed mostly of rough endoplasmic reticulum and is lost after neuronal injury or axonal degeneration...Carson, 1990). For cresyl violet histochemistry, tissue was rinsed and dried overnight before staining . Sections were dehydrated through graded...five minutes. Differentiation was timed such that both Nissl substance and cell nuclei were clearly visible. Slides were washed in graded alcohol and
Alansari, A; Sun, Y
2017-10-01
The objective of this study is to compare the mechanical behaviour of thermally oxidised commercially pure titanium (CP-Ti) and commercially pure zirconium (CP-Zr). For this purpose, these two bio-metals were thermally oxidised under the same condition (650°C for 6h) and the oxidised specimens were characterised using various analytical and experimental techniques, including oxygen uptake analysis, layer thickness and hardness measurements, scratch tests, dry sliding friction and wear tests and tribocorrosion tests in Ringer's solution. The results show that under the present thermal oxidation condition, 4 times more oxygen is introduced into CP-Zr than into CP-Ti and the oxide layer produced on CP-Zr is nearly 6 times thicker than that on CP-Ti. Thermally oxidised CP-Zr possesses a higher hardness, a deeper hardening depth and better scratch resistance than thermally oxidised CP-Ti. Under dry sliding and tribocorrosion conditions, thermally oxidised CP-Zr also possesses much better resistance to material removal and a higher load bearing capacity than thermally oxidised CP-Ti. Thus, thermally oxidised Zr possesses much better mechanical behaviour than thermally oxidised Ti. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bio-inspired scale-like surface textures and their tribological properties.
Greiner, Christian; Schäfer, Michael
2015-06-30
Friction, wear and the associated energy dissipation are major challenges in all systems containing moving parts. Examples range from nanoelectromechanical systems over hip prosthesis to off-shore wind turbines. Bionic approaches have proven to be very successful in many engineering problems, while investigating the potential of a bio-inspired approach in creating morphological surface textures is a relatively new field of research. Here, we developed laser-created textures inspired by the scales found on the skin of snakes and certain lizards. We show that this bio-inspired surface morphology reduced dry sliding friction forces by more than 40%. In lubricated contacts the same morphology increased friction by a factor of three. Two different kinds of morphologies, one with completely overlapping scales and one with the scales arranged in individual rows, were chosen. In lubricated as well as unlubricated contacts, the surface texture with the scales in rows showed lower friction forces than the completely overlapping ones. We anticipate that these results could have significant impact in all dry sliding contacts, ranging from nanoelectromechanical and micro-positioning systems up to large-scale tribological contacts which cannot be lubricated, e.g. because they are employed in a vacuum environment.
Role of 3D force networks in linking grain scale to macroscale processes in sheared granular debris
NASA Astrophysics Data System (ADS)
Mair, K.; Jettestuen, E.; Abe, S.
2013-12-01
Active faults, landslides and subglacial tills contain accumulations of granular debris that evolve during sliding. The macroscopic motion in these environments is at least to some extent determined by processes operating in this sheared granular material. A valid question is how the local behavior at the individual granular contacts actually sums up to influence macroscopic sliding. Laboratory experiments and numerical modeling can potentially help elucidate this. Observations of jamming (stick) and unjamming (flow) as well as concentrated shear bands on the scale of 5-10 grains suggest that a simple continuum description may be insufficient to capture important elements of the behavior. We therefore seek a measure of the organization of the granular fabric and the 3D structure of the load bearing skeleton that effectively demonstrates how the individual grain interactions are manifested in the macroscopic sliding behavior we observe. Contact force networks are an expression of this. Here we investigate the structure and variability of the most connected system spanning force networks produced in 3D discrete element models of granular layers under shear. We use percolation measures to identify, characterize, compare and track the evolution of these strongly connected contact force networks. We show that specific topological measures used in describing the networks, such as number of contacts and coordination number, are sensitive to grain size distribution (and likely the grain shape) of the material as well as loading conditions. Hence, faults of different maturity would be expected to accommodate shear in different ways. Distinct changes in the topological characteristics i.e. the geometry of strong force networks with accumulated strain are directly correlated to fluctuations in macroscopic shearing resistance. This suggests that 3D force networks play an important bridging role between individual grain scale processes and macroscopic sliding behavior.
NASA Astrophysics Data System (ADS)
Costa, R. P. C.; Lima-Oliveira, D. A.; Marciano, F. R.; Lobo, A. O.; Corat, E. J.; Trava-Airoldi, V. J.
2013-11-01
This paper reports the influence of the adhesion interlayer between stainless steel and diamond-like carbon (DLC) films in two different contact conditions: in dry air and deionized water. The water was the liquid used to understand the mechanism and chemical reactions of the tribolayer formation under boundary lubrication. The effect of silicon and carbonitride adhesion interlayer was investigated on uncoated and coated DLC films. The results show that DLC/DLC pairs using carbonitride in air (30% RH) showed 60% less friction coefficient and wear less than three orders of magnitude than DLC/DLC pairs using silicon as interlayer. In deionized water, DLC/DLC pairs using carbonitride as interlayer showed 31% less friction coefficient when compared to DLC/DLC pairs with silicon. Raman related the chemical and structural changes in the DLC films during sliding in air and in the presence of water. Scratch tests showed a critical load of 14 N and 33 N in DLC films with silicon and carbonitride, respectively.
Analysis of Microstructure and Sliding Wear Behavior of Co1.5CrFeNi1.5Ti0.5 High-Entropy Alloy
NASA Astrophysics Data System (ADS)
Lentzaris, K.; Poulia, A.; Georgatis, E.; Lekatou, A. G.; Karantzalis, A. E.
2018-04-01
Α Co1.5CrFeNi1.5Ti0.5 high-entropy alloy (HEA) of the well-known family of CoCrFeNiTi has been designed using empirical parameters. The aim of this design was the production of a HEA with fcc structure that gives ductile behavior and also high strength because of the solid solution effect. The VEC calculations (8.1) supported the fcc structure while the δ factor calculations (4.97) not being out of the limit values, advised a significant lattice distortion. From the other hand, the ΔΗ mix calculations (- 9.64 kJ/mol) gave strong indications that no intermetallic would be formed. In order to investigate its potential application, the Co1.5CrFeNi1.5Ti0.5 HEA was prepared by vacuum arc melting and a primary assessment of its surface degradation response was conducted by means of sliding wear testing using different counterbody systems for a total sliding distance of 1000 m. An effort to correlate the alloy's wear response with the microstructural characteristics was attempted. Finally, the wear behavior of the Co1.5CrFeNi1.5Ti0.5 HEA was compared with that of two commercially used wear-resistant alloys. The results obtained provided some first signs of the high-entropy alloys' better wear performance when tested under sliding conditions against a steel ball.
Friction of atomically stepped surfaces
NASA Astrophysics Data System (ADS)
Dikken, R. J.; Thijsse, B. J.; Nicola, L.
2017-03-01
The friction behavior of atomically stepped metal surfaces under contact loading is studied using molecular dynamics simulations. While real rough metal surfaces involve roughness at multiple length scales, the focus of this paper is on understanding friction of the smallest scale of roughness: atomic steps. To this end, periodic stepped Al surfaces with different step geometry are brought into contact and sheared at room temperature. Contact stress that continuously tries to build up during loading, is released with fluctuating stress drops during sliding, according to the typical stick-slip behavior. Stress release occurs not only through local slip, but also by means of step motion. The steps move along the contact, concurrently resulting in normal migration of the contact. The direction of migration depends on the sign of the step, i.e., its orientation with respect to the shearing direction. If the steps are of equal sign, there is a net migration of the entire contact accompanied by significant vacancy generation at room temperature. The stick-slip behavior of the stepped contacts is found to have all the characteristic of a self-organized critical state, with statistics dictated by step density. For the studied step geometries, frictional sliding is found to involve significant atomic rearrangement through which the contact roughness is drastically changed. This leads for certain step configurations to a marked transition from jerky sliding motion to smooth sliding, making the final friction stress approximately similar to that of a flat contact.
Push-out tests on a new silicon carbide/reaction-bonded silicon carbide ceramic matrix composite
NASA Technical Reports Server (NTRS)
Curtin, William A.; Eldridge, Jeffrey I.; Srinivasan, Gajawalli V.
1993-01-01
Fiber push-out tests have been performed on a ceramic matrix composite consisting of carborundum-sintered SiC fibers, with a BN coating, embedded in a reaction-bonded SiC matrix. Analysis of the push-out data, utilizing the most complete theory presently available, shows that one of the fiber/coating/matrix interfaces has a low fracture energy (one-tenth that of the fiber) and a moderate sliding resistance of about 8 MPa. The debonded sliding interface shows some continuous but minor abrasion, which appears to increase the sliding resistance, but overall the system exhibits very clean smooth sliding. The tensile response of a full-scale composite is then modeled using data obtained here and known fiber strengths to demonstrate the good composite behavior predicted for this material.
Ferguson rock slide buries California State Highway near Yosemite National Park
Harp, E.L.; Reid, M.E.; Godt, J.W.; DeGraff, J.V.; Gallegos, A.J.
2008-01-01
During spring 2006, talus from the toe area of a rock-block slide of about 800,000 m3 buried California State Highway 140, one of the main routes into heavily-visited Yosemite National Park, USA. Closure of the highway for 92 days caused business losses of about 4.8 million USD. The rock slide, composed of slate and phyllite, moved slowly downslope from April to June 2006, creating a fresh head scarp with 9-12 m of displacement. Movement of the main rock slide, a re-activation of an older slide, was triggered by an exceptionally wet spring 2006, following a very wet spring 2005. As of autumn 2006, most of the main slide appeared to be at rest, although rocks occasionally continued to fall from steep, fractured rock masses at the toe area of the slide. Future behavior of the slide is difficult to predict, but possible scenarios range from continued scattered rock fall to complete rapid failure of the entire mass. Although unlikely except under very destabilizing circumstances, a worst-case, rapid failure of the entire rock slide could extend across the Merced River, damming the river and creating a reservoir. As a temporary measure, traffic has been rerouted to the opposite side of the Merced River at about the same elevation as the buried section of Highway 140. A state-of-the-art monitoring system has been installed to detect movement in the steep talus slope, movement of the main slide mass, local strong ground motion from regional earthquakes, and sudden changes in stream levels, possibly indicating damming of the river by slide material. ?? 2008 Springer-Verlag.
Numerical simulation of failure behavior of granular debris flows based on flume model tests.
Zhou, Jian; Li, Ye-xun; Jia, Min-cai; Li, Cui-na
2013-01-01
In this study, the failure behaviors of debris flows were studied by flume model tests with artificial rainfall and numerical simulations (PFC(3D)). Model tests revealed that grain sizes distribution had profound effects on failure mode, and the failure in slope of medium sand started with cracks at crest and took the form of retrogressive toe sliding failure. With the increase of fine particles in soil, the failure mode of the slopes changed to fluidized flow. The discrete element method PFC(3D) can overcome the hypothesis of the traditional continuous medium mechanic and consider the simple characteristics of particle. Thus, a numerical simulations model considering liquid-solid coupled method has been developed to simulate the debris flow. Comparing the experimental results, the numerical simulation result indicated that the failure mode of the failure of medium sand slope was retrogressive toe sliding, and the failure of fine sand slope was fluidized sliding. The simulation result is consistent with the model test and theoretical analysis, and grain sizes distribution caused different failure behavior of granular debris flows. This research should be a guide to explore the theory of debris flow and to improve the prevention and reduction of debris flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rani, R.; Kumar, N., E-mail: niranjan@igcar.gov.in; Lin, I-Nan
Nanostructured diamond films are having numerous unique properties including superior tribological behavior which is promising for enhancing energy efficiency and life time of the sliding devices. High wear resistance is the principal criterion for the smooth functioning of any sliding device. Such properties are achievable by tailoring the grain size and grain boundary volume fraction in nanodiamond film. Ultra-nanocrystalline diamond (UNCD) film was attainable using optimized gas plasma condition in a microwave plasma enhanced chemical vapor deposition (MPECVD) system. Crystalline phase of ultra-nanodiamond grains with matrix phase of amorphous carbon and short range ordered graphite are encapsulated in nanowire shapedmore » morphology. Film showed ultra-high wear resistance and frictional stability in micro-tribological contact conditions. The negligible wear of film at the beginning of the tribological contact was later transformed into the wearless regime for prolonged sliding cycles. Both surface roughness and high contact stress were the main reasons of wear at the beginning of sliding cycles. However, the interface gets smoothened due to continuous sliding, finally leaded to the wearless regime.« less
Kitt, Alexander L; Qi, Zenan; Rémi, Sebastian; Park, Harold S; Swan, Anna K; Goldberg, Bennett B
2013-06-12
Strain, bending rigidity, and adhesion are interwoven in determining how graphene responds when pulled across a substrate. Using Raman spectroscopy of circular, graphene-sealed microchambers under variable external pressure, we demonstrate that graphene is not firmly anchored to the substrate when pulled. Instead, as the suspended graphene is pushed into the chamber under pressure, the supported graphene outside the microchamber is stretched and slides, pulling in an annulus. Analyzing Raman G band line scans with a continuum model extended to include sliding, we extract the pressure dependent sliding friction between the SiO2 substrate and mono-, bi-, and trilayer graphene. The sliding friction for trilayer graphene is directly proportional to the applied load, but the friction for monolayer and bilayer graphene is inversely proportional to the strain in the graphene, which is in violation of Amontons' law. We attribute this behavior to the high surface conformation enabled by the low bending rigidity and strong adhesion of few layer graphene.
Fault Frictional Stability in a Nuclear Waste Repository
NASA Astrophysics Data System (ADS)
Orellana, Felipe; Violay, Marie; Scuderi, Marco; Collettini, Cristiano
2016-04-01
Exploitation of underground resources induces hydro-mechanical and chemical perturbations in the rock mass. In response to such disturbances, seismic events might occur, affecting the safety of the whole engineering system. The Mont Terri Rock Laboratory is an underground infrastructure devoted to the study of geological disposal of nuclear waste in Switzerland. At the site, it is intersected by large fault zones of about 0.8 - 3 m in thickness and the host rock formation is a shale rock named Opalinus Clay (OPA). The mineralogy of OPA includes a high content of phyllosilicates (50%), quartz (25%), calcite (15%), and smaller proportions of siderite and pyrite. OPA is a stiff, low permeable rock (2×10-18 m2), and its mechanical behaviour is strongly affected by the anisotropy induced by bedding planes. The evaluation of fault stability and associated fault slip behaviour (i.e. seismic vs. aseismic) is a major issue in order to ensure the long-term safety and operation of the repository. Consequently, experiments devoted to understand the frictional behaviour of OPA have been performed in the biaxial apparatus "BRAVA", recently developed at INGV. Simulated fault gouge obtained from intact OPA samples, were deformed at different normal stresses (from 4 to 30 MPa), under dry and fluid-saturated conditions. To estimate the frictional stability, the velocity-dependence of friction was evaluated during velocity steps tests (1-300 μm/s). Slide-hold-slide tests were performed (1-3000 s) to measure the amount of frictional healing. The collected data were subsequently modelled with the Ruina's slip dependent formulation of the rate and state friction constitutive equations. To understand the deformation mechanism, the microstructures of the sheared gouge were analysed. At 7 MPa normal stress and under dry conditions, the friction coefficient decreased from a peak value of μpeak,dry = 0.57 to μss,dry = 0.50. Under fluid-saturated conditions and same normal stress, the friction coefficient decreased from a peak value of μpeak,sat = 0.45 to μss,sat = 0.34. Additionally, it has been observed that the weakening distance Dw is smaller under fluid- saturated conditions (˜4 mm) compared to dry conditions (˜6 mm). Results showed a linear decrease of both peak friction and steady state friction when normal stress increases. When fluid- saturation degree of gouges is reduced, gouge samples underwent a transition from velocity strengthening to velocity weakening behaviour, thus indicating a potentially unstable frictional behaviour of the fault. Furthermore, under both saturated and dry conditions, the frictional healing rate showed a low recovery of the friction coefficient under different holding times. Our experiments indicate that the frictional behaviour of Opalinus Clay is characterized by complex processes depending upon normal stress, sliding velocity, and saturation degree of the samples. This complexity highlights the need for further experiments in order to better evaluate the seismic risk during long-term nuclear waste disposal within the OPA clay formation.
An analysis of the wear behavior of SiC whisker reinforced alumina from 25 to 1200 C
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher
1991-01-01
A model is described for predicting the wear behavior of whisker reinforced ceramics. The model was successfully applied to a silicon carbide whisker reinforced alumina ceramic composite subjected to sliding contact. The model compares the friction forces on the whiskers due to sliding, which act to pull or push them out of the matrix, to the clamping or compressive forces on the whiskers due to the matrix, which act to hold the whiskers in the composite. At low temperatures, the whiskers are held strongly in the matrix and are fractured into pieces during the wear process along with the matrix. At elevated temperatures differential thermal expansion between the whiskers and matrix can cause loosening of the whiskers and lead to pullout during the wear process and to higher wear. The model, which represents the combination of elastic stress analysis and a friction heating analysis, predicts a transition temperature at which the strength of the whiskers equals the clamping force holding them in the matrix. Above the transition the whiskers are pulled out of the matrix during sliding, and below the transition the whiskers are simply fractured. The existence of the transition gives rise to a dual wear mode or mechanism behavior for this material which was observed in laboratory experiments. The results from this model correlate well with experimentally observed behavior indicating that the model may be useful in obtaining a better understanding of material behavior and in making material improvements.
An analysis of the wear behavior of SiC whisker-reinforced alumina from 25 to 1200 C
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher
1993-01-01
A model is described for predicting the wear behavior of whisker reinforced ceramics. The model was successfully applied to a silicon carbide whisker reinforced alumina ceramic composite subjected to sliding contact. The model compares the friction forces on the whiskers due to sliding, which act to pull or push them out of the matrix, to the clamping or compressive forces on the whiskers due to the matrix, which act to hold the whiskers in the composite. At low temperatures, the whiskers are held strongly in the matrix and are fractured into pieces during the wear process along with the matrix. At elevated temperatures differential thermal expansion between the whiskers and matrix can cause loosening of the whiskers and lead to pullout during the wear process and to higher wear. The model, which represents the combination of elastic stress analysis and a friction heating analysis, predicts a transition temperature at which the strength of the whiskers equals the clamping force holding them in the matrix. Above the transition the whiskers are pulled out of the matrix during sliding, and below the transition the whiskers are simply fractured. The existence of the transition gives rise to a dual wear mode or mechanism behavior for this material which was observed in laboratory experiments. The results from this model correlate well with experimentally observed behavior indicating that the model may be useful in obtaining a better understanding of material behavior and in making material improvements.
Steady-state wear and friction in boundary lubrication studies
NASA Technical Reports Server (NTRS)
Loomis, W. R.; Jones, W. R., Jr.
1980-01-01
A friction and wear study was made at 20 C to obtain improved reproducibility and reliability in boundary lubrication testing. Ester-base and C-ether-base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a friction and wear apparatus. Conditions included loads of 1/2 and 1 kg and sliding velocities of 3.6 to 18.2 m/min in a dry air atmosphere and stepwise time intervals from 1 to 250 min for wear measurements. The wear rate results were compared with those from previous studies where a single 25 min test period was used. Satisfactory test conditions for studying friction and wear in boundary lubrication for this apparatus were found to be 1 kg load; sliding velocities of 7.1 to 9.1 m/min (50 rpm disk speed); and use of a time stepwise test procedure. Highly reproducible steady-state wear rates and steady-state friction coefficients were determined under boundary conditions. Wear rates and coefficients of friction were constant following initially high values during run-in periods.
Uncertainty Quantification for Robust Control of Wind Turbines using Sliding Mode Observer
NASA Astrophysics Data System (ADS)
Schulte, Horst
2016-09-01
A new quantification method of uncertain models for robust wind turbine control using sliding-mode techniques is presented with the objective to improve active load mitigation. This approach is based on the so-called equivalent output injection signal, which corresponds to the average behavior of the discontinuous switching term, establishing and maintaining a motion on a so-called sliding surface. The injection signal is directly evaluated to obtain estimates of the uncertainty bounds of external disturbances and parameter uncertainties. The applicability of the proposed method is illustrated by the quantification of a four degree-of-freedom model of the NREL 5MW reference turbine containing uncertainties.
Buccola, Norman L.; Stonewall, Adam J.; Rounds, Stewart A.
2015-01-01
Estimated egg-emergence days for endangered Upper Willamette River Chinook salmon (Oncorhynchus tshawytscha) and Upper Willamette River winter steelhead (Oncorhynchus mykiss) were assessed for all scenarios. Estimated spring Chinook fry emergence under SlidingWeir scenarios was 9 days later immediately downstream of Big Cliff Dam, and 4 days later at Greens Bridge compared with existing structural scenarios at Detroit Dam. Despite the inclusion of a hypothetical sliding weir at Detroit Dam, temperatures exceeded without-dams temperatures during November and December. These late-autumn exceedances likely represent the residual thermal effect of Detroit Lake operated to meet minimum dry-season release rates (supporting instream habitat and irrigation requirements) and lake levels specified by the current (2014) operating rules (supporting recreation and flood mitigation).
NASA Astrophysics Data System (ADS)
Wu, F.; Wu, T.-H.; Li, X.-Y.
2018-03-01
This article aims to present a systematic indentation theory on a half-space of multi-ferroic composite medium with transverse isotropy. The effect of sliding friction between the indenter and substrate is taken into account. The cylindrical flat-ended indenter is assumed to be electrically/magnetically conducting or insulating, which leads to four sets of mixed boundary-value problems. The indentation forces in the normal and tangential directions are related to the Coulomb friction law. For each case, the integral equations governing the contact behavior are developed by means of the generalized method of potential theory, and the corresponding coupling field is obtained in terms of elementary functions. The effect of sliding on the contact behavior is investigated. Finite element method (FEM) in the context of magneto-electro-elasticity is developed to discuss the validity of the analytical solutions. The obtained analytical solutions may serve as benchmarks to various simplified analyses and numerical codes and as a guide for future experimental studies.
NASA Astrophysics Data System (ADS)
Sistani, Habiballah; Karki, Santosh; Archer, Jieutonne J.; Shi, Fengjian; Levis, Robert J.
2017-05-01
A nonresonant, femtosecond (fs) laser is employed to desorb samples of Victoria blue deposited on stainless steel or indium tin oxide (ITO) slides using either electrospray deposition (ESD) or dried droplet deposition. The use of ESD resulted in uniform films of Victoria blue whereas the dried droplet method resulted in the formation of a ring pattern of the dye. Laser electrospray mass spectrometry (LEMS) measurements of the ESD-prepared films on either substrate were similar and revealed lower average relative standard deviations for measurements within-film (20.9%) and between-films (8.7%) in comparison to dried droplet (75.5% and 40.2%, respectively). The mass spectral response for ESD samples on both substrates was linear (R2 > 0.99), enabling quantitative measurements over the selected range of 7.0 × 10-11 to 2.8 × 10-9 mol, as opposed to the dried droplet samples where quantitation was not possible (R2 = 0.56). The limit of detection was measured to be 210 fmol.
Frictional strength of wet and dry montmorillonite
Morrow, Carolyn A.; Moore, Diane E.; Lockner, David A.
2017-01-01
Montmorillonite is a common mineral in fault zones, and its low strength relative to other common gouge minerals is important in many models of fault rheology. However, the coefficient of friction, μ, varies with degree of saturation and is not well constrained in the literature due to the difficulty of establishing fully drained or fully dried states in the laboratory. We measured μ of both saturated and oven-dried montmorillonite at normal stresses up to 700 MPa. Care was taken to shear saturated samples slowly enough to avoid pore fluid overpressure. For saturated samples, μ increased from 0.10 to 0.28 with applied effective normal stress, while for dry samples μ decreased from 0.78 to 0.45. The steady state rate dependence of friction, (a − b), was positive, promoting stable sliding. The wide disparity in reported frictional strengths can be attributed to experimental procedures that promote differing degrees of partial saturation or overpressured pore fluid conditions.
Modeling and Investigation of the Wear Resistance of Salt Bath Nitrided Aisi 4140 via ANN
NASA Astrophysics Data System (ADS)
Ekinci, Şerafettin; Akdemir, Ahmet; Kahramanli, Humar
2013-05-01
Nitriding is usually used to improve the surface properties of steel materials. In this way, the wear resistance of steels is improved. We conducted a series of studies in order to investigate the microstructural, mechanical and tribological properties of salt bath nitrided AISI 4140 steel. The present study has two parts. For the first phase, the tribological behavior of the AISI 4140 steel which was nitrided in sulfinuz salt bath (SBN) was compared to the behavior of the same steel which was untreated. After surface characterization using metallography, microhardness and sliding wear tests were performed on a block-on-cylinder machine in which carbonized AISI 52100 steel discs were used as the counter face. For the examined AISI 4140 steel samples with and without surface treatment, the evolution of both the friction coefficient and of the wear behavior were determined under various loads, at different sliding velocities and a total sliding distance of 1000 m. The test results showed that wear resistance increased with the nitriding process, friction coefficient decreased due to the sulfur in salt bath and friction coefficient depended systematically on surface hardness. For the second part of this study, four artificial neural network (ANN) models were designed to predict the weight loss and friction coefficient of the nitrided and unnitrided AISI 4140 steel. Load, velocity and sliding distance were used as input. Back-propagation algorithm was chosen for training the ANN. Statistical measurements of R2, MAE and RMSE were employed to evaluate the success of the systems. The results showed that all the systems produced successful results.
Hortolà, Policarp
2016-11-01
Apart from their forensic significance in crime investigation, human bloodstains have an anthropological interest due to their occurrence on certain traditional weapons and ritual objects. Previously, a guiding study of erythrocytes in experimental samples including domestic sheep (Ovis aries) tibia was carried out using a scanning electron microscope (SEM). Here, a comparative SEM study to reveal the potential differences in bloodstain surface morphology as a function of intra-sample (smear region) and inter-sample (individual smear, smearing mechanism, bone origin) parameters is reported. A fragment of emu (Dromaius novaehollandiae) tibiotarsus was smeared with an adult man's peripheral blood. After air-drying and storing indoors, the boundary and neighbouring inner areas of the three individual bloodstains obtained were examined via secondary electrons in a variable-pressure SEM working in low-vacuum mode. As a whole, desiccation microcracks were present, the limits between the smear and the substrate appeared poorly defined, and no erythrocyte negative replicas were observed in the examined areas. In addition, a putative fibrin network, more or less embedded in the dried plasma matrix, was observed in the smears' boundary. Regarding the smear region in sliding smears, the periphery and boundary revealed to be different, while the head and tail were similar. Considering individual sliding smears, they had similar characteristics. Relating to the smear region as a function of the smearing mechanism, the periphery was different whether sliding or touching, while the boundary was similar in sliding and touching smears. Concerning the smear region as a function of the bone origin, the periphery revealed to be similar in both ratite and mammalian bone, while the boundary did different in ratite and mammalian bone. The results of this study show that SEM examination can be used fruitfully to detect bloodstains on ratite bone. Combined with previous SEM results in domestic sheep bone, they suggest, further, that blood remains can be detected on objects made of bone irrespectively of the mammalian or ratite origin of this raw material. Copyright © 2016 Elsevier Ltd. All rights reserved.
Scuffing of aluminum/steel contacts under dry sliding conditions
NASA Astrophysics Data System (ADS)
Sheiretov, Todor Konstantinov
Some typical applications where scuffing may occur are gear teeth, piston rings and cylinder pairs, cams and followers, splines, sleeve bearings, and parts of swash and wobble plate compressors. Unlike other tribology-related failures, scuffing occurs very fast, without any warning, and usually leads to the complete destruction of the sliding pair. Practical experience with steel has helped to outline safe ranges of operation for some components. Very little, however, is known about aluminum, which is the second most commonly used engineering metal. The aim of this study is to obtain a better understanding scuffing and seizure of aluminum/steel contacts. The research includes an experimental study of scuffing of aluminum/steel contacts under dry sliding conditions, a study of the physics of the scuffing process, evaluation of various hypotheses for scuffing, and modeling of scuffing. The experiments are conducted in a custom-designed tribometer, which provides accurate control of the environmental conditions. Special instrumentation, experimental procedures and software are developed as a part of the experimental program. These provide a reliable reproduction and identification of scuffing under laboratory conditions. The scuffing characteristics of five materials are obtained in air and refrigerant (R134a) environments. The effects of load, sliding velocity, mechanical strength, environmental temperature, specimen geometry, time, loading history, and type of environment are evaluated. The mechanisms leading to scuffing are studied by examination of surfaces, subsurfaces and wear debris of specimens in the process of scuffing. Quantitative measurements of subsurface plastic strain are also obtained. The theoretical part of the study includes the development of a finite element model for the contact of runned-in rough surfaces and several other models for subsurface stresses, temperatures, and strains. These models provide information about the local conditions in the subsurface. Based on the experimental observations and the scuffing models a new hypothesis for scuffing is proposed. According to this hypothesis, scuffing involves initiation of cracks due to subsurface plastic deformation, propagation of these cracks leading to the removal of the existing protective surface layers, and finally cold welding due to adhesion between bare metal surfaces.
NASA Technical Reports Server (NTRS)
Eldridge, J. I.; Bansal, N. P.; Bhatt, R. T.
1998-01-01
Interfacial debond cracks and fiber/matrix sliding stresses in ceramic matrix composites (CMCs) can evolve under cyclic fatigue conditions as well as with changes in the environment, strongly affecting the crack growth behavior, and therefore, the useful service lifetime of the composite. In this study, room temperature cyclic fiber push-in testing was applied to monitor the evolution of frictional sliding stresses and fiber sliding distances with continued cycling in both C- and BN-coated Hi-Nicalon SiC fiber-reinforced CMCs. A SiC matrix composite reinforced with C-coated Hi-Nical on fibers as well as barium strontium aluminosilicate (BSAS) matrix composites reinforced with BN-coated (four different deposition processes compared) Hi-Nicalon fibers were examined. For failure at a C interface, test results indicated progressive increases in fiber sliding distances during cycling in room air but not in nitrogen. These results suggest the presence of moisture will promote crack growth when interfacial failure occurs at a C interface. While short-term testing environmental effects were not apparent for failure at the BN interfaces, long-term exposure of partially debonded BN-coated fibers to humid air resulted in large increases in fiber sliding distances and decreases in interfacial sliding stresses for all the BN coatings, presumably due to moisture attack. A wide variation was observed in debond and frictional sliding stresses among the different BN coatings.
Friction of ice. [on Ganymede, Callisto, and Europa surfaces
NASA Technical Reports Server (NTRS)
Beeman, M.; Durham, W. B.; Kirby, S. H.
1988-01-01
Frictional sliding experiments were performed on saw-cut samples of laboratory-made polycrystalline water ice, prepared in the same way as the material used by Kirby et al. (1987) in ice deformation experiments. The data show that the maximum frictional stress is a function of the normal stress but is not measurably dependent on temperature or sliding rate over the ranges covered in these experiments (77-115 K and 0.0003-0.03 mm/s, respectively). The sliding behavior was invariably stick slip, with the sliding surfaces exhibiting only minor gouge development. In samples with anomalously low strength, a curious arrangement of densely packed short vertical fractures was observed. The results of these experiments were applied to a model of near-surface tectonic activity on Ganymede, one of Jupiter's icy moons. The results indicate that a global expansion on Ganymede of 3 linear percent will cause extensional movement on preexisting faults at depths to 7 + or - 3 km.
ERIC Educational Resources Information Center
School Science Review, 1983
1983-01-01
Provided are reviews of science films, slides, audio cassettes, and wall charts. Each review includes title, source, country of origin, description of subject matter presented, appraisal, and target audience. Among the topics considered are smell/taste, grasshopper behavior, photography, bat behavior/flight, pond life, exploring planets, locusts,…
NASA Astrophysics Data System (ADS)
Saemundsson, Thorsteinn; Morino, Costanza; Kristinn Helgason, Jón; Conway, Susan J.; Pétursson, Halldór G.
2017-04-01
On the 20th of September in 2012, a large debris slide occurred in the Móafellshyrna Mountain in the Tröllaskagi peninsula, central north Iceland. Three factors are likely to have contributed to the failure of the slope: intense precipitation, earthquake activity and thawing of ground ice. The weather conditions prior the slide were somewhat unusual, with a warm and dry summer. From the 20th of August to the 20th of September, about 440 mm of precipitation fell in the area, where the mean annual precipitation at the nearest station is around 670 mm. The slide initiated after this thirty day period of intense precipitation, followed by a seismic sequence in the Eyjafjarðaráll graben, located about 60 km NNE of Móafellshyrna Mountain, a sequence that started on the 19th of September. The slide originated at elevation of 870 m a.s.l. on the NW-slope of the mountain. The total volume of the debris slide is estimated around 500,000 m3 and that its primary cause was intense precipitation. We cannot exclude the influence of the seismic sequence as a secondary contributing factor. The presence of ice-cemented blocks of talus immediately after the debris slide shows that thawing of ground ice could also have played an important role as a triggering factor. Ice-cemented blocks of talus have been observed in the deposits of two other recent landslides in northern Iceland, in the Torfufell Mountain and the Árnesfjall Mountain. The source areas for both the Móafellshyrna and the Torfufell slides are within the lower elevation limit of mountain permafrost in northern Iceland but the source area of the Árnesfjall slide is at much lower elevation, around 350 m a.s.l. The fact that there are now three documented landslides which are linked to ground ice-melting suggests that discontinuous permafrost is degrading in Iceland, consistent with the decadal trend of increasing atmospheric temperature in Iceland due to climate change. This study highlights that ground ice thaw could represent a new source of hazard in Iceland. The knowledge of the detailed distribution of mountain permafrost on the island is poorly constrained, making it is hard to predict where the next hazardous slide could occur in the future - therefore a making this a priority for future research.
Achieving increased bandwidth for 4 degree of freedom self-tuning energy harvester
NASA Astrophysics Data System (ADS)
Staaf, L. G. H.; Smith, A. D.; Köhler, E.; Lundgren, P.; Folkow, P. D.; Enoksson, P.
2018-04-01
The frequency response of a self-tuning energy harvester composed of two piezoelectric cantilevers connected by a middle beam with a sliding mass is investigated. Measurements show that incorporation of a free-sliding mass increases the bandwidth. Using an analytical model, the system is explained through close investigation of the resonance modes. Resonance mode behavior further suggests that, by breaking the symmetry of the system, even broader bandwidths are achievable.
Tribological Characteristics and Applications of Superhard Coatings: CVD Diamond, DLC, and c-BN
NASA Technical Reports Server (NTRS)
Miyoshi, Kazuhisa; Murakawa, Masao; Watanabe, Shuichi; Takeuchi, Sadao; Wu, Richard L. C.
1999-01-01
Results of fundamental research on the tribological properties of chemical-vapor-deposited (CVD) diamond, diamondlike carbon, and cubic boron nitride films in sliding contact with CVD diamond in ultrahigh vacuum, dry nitrogen, humid air, and water are discussed. Furthermore, the actual and potential applications of the three different superhard coatings in the field of tribology technology, particularly for wear parts and tools, are reviewed.
Multilevel model of polycrystalline materials: grain boundary sliding description
NASA Astrophysics Data System (ADS)
Sharifullina, E.; Shveykin, A.; Trusov, P.
2017-12-01
Material behavior description in a wide range of thermomechanical effects is one of the topical areas in mathematical modeling. Inclusion of grain boundary sliding as an important mechanism of polycrystalline material deformation at elevated temperatures and predominant deformation mechanism of metals and alloys in structural superplasticity allows to simulate various deformation regimes and their transitions (including superplasticity regime with switch-on and switch-off regimes). The paper is devoted to description of grain boundary sliding in structure of two-level model, based on crystal plasticity, and relations for determination the contribution of this mechanism to inelastic deformation. Some results are presented concerning computational experiments of polycrystalline representative volume deformation using developed model.
Wallace, Joseph B.; Chen, Di; Shao, Lin
2015-11-03
Understanding radiation effects on the mechanical properties of SiC composites is important to their application in advanced reactor designs. By means of molecular dynamics simulations, we found that due to strong interface bonding between the graphene layers and SiC, the sliding friction of SiC fibers is largely determined by the frictional behavior between graphene layers. Upon sliding, carbon displacements between graphene layers can act as seed atoms to induce the formation of single carbon atomic chains (SCACs) by pulling carbon atoms from the neighboring graphene planes. The formation, growth, and breaking of SCACs determine the frictional response to irradiation.
Jiang, Liren
2017-01-01
Background The aim was to develop scalable Whole Slide Imaging (sWSI), a WSI system based on mainstream smartphones coupled with regular optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry objective lenses of different magnifications, and reasonably high throughput. These performance metrics should be evaluated by expert pathologists and match those of high-end scanners. Objective The aim was to develop scalable Whole Slide Imaging (sWSI), a whole slide imaging system based on smartphones coupled with optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry object lens of different magnification. All performance metrics should be evaluated by expert pathologists and match those of high-end scanners. Methods In the sWSI design, the digitization process is split asynchronously between light-weight clients on smartphones and powerful cloud servers. The client apps automatically capture FoVs at up to 12-megapixel resolution and process them in real-time to track the operation of users, then give instant feedback of guidance. The servers first restitch each pair of FoVs, then automatically correct the unknown nonlinear distortion introduced by the lens of the smartphone on the fly, based on pair-wise stitching, before finally combining all FoVs into one gigapixel VS for each scan. These VSs can be viewed using Internet browsers anywhere. In the evaluation experiment, 100 frozen section slides from patients randomly selected among in-patients of the participating hospital were scanned by both a high-end Leica scanner and sWSI. All VSs were examined by senior pathologists whose diagnoses were compared against those made using optical microscopy as ground truth to evaluate the image quality. Results The sWSI system is developed for both Android and iPhone smartphones and is currently being offered to the public. The image quality is reliable and throughput is approximately 1 FoV per second, yielding a 15-by-15 mm slide under 20X object lens in approximately 30-35 minutes, with little training required for the operator. The expected cost for setup is approximately US $100 and scanning each slide costs between US $1 and $10, making sWSI highly cost-effective for infrequent or low-throughput usage. In the clinical evaluation of sample-wise diagnostic reliability, average accuracy scores achieved by sWSI-scan-based diagnoses were as follows: 0.78 for breast, 0.88 for uterine corpus, 0.68 for thyroid, and 0.50 for lung samples. The respective low-sensitivity rates were 0.05, 0.05, 0.13, and 0.25 while the respective low-specificity rates were 0.18, 0.08, 0.20, and 0.25. The participating pathologists agreed that the overall quality of sWSI was generally on par with that produced by high-end scanners, and did not affect diagnosis in most cases. Pathologists confirmed that sWSI is reliable enough for standard diagnoses of most tissue categories, while it can be used for quick screening of difficult cases. Conclusions As an ultra-low-cost alternative to whole slide scanners, diagnosis-ready VS quality and robustness for commercial usage is achieved in the sWSI solution. Operated on main-stream smartphones installed on normal optical microscopes, sWSI readily offers affordable and reliable WSI to resource-limited or infrequent clinical users. PMID:28916508
Effect of Deformation Mode on the Wear Behavior of NiTi Shape Memory Alloys
NASA Astrophysics Data System (ADS)
Yan, Lina; Liu, Yong
2016-06-01
Owing to good biocompatibility, good fatigue resistance, and excellent superelasticity, various types of bio-medical devices based on NiTi shape memory alloy (SMA) have been developed. Due to the complexity in deformation mode in service, for example NiTi implants, accurate assessment/prediction of the surface wear process is difficult. This study aims at providing a further insight into the effect of deformation mode on the wear behavior of NiTi SMA. In the present study, two types of wear testing modes were used, namely sliding wear mode and reciprocating wear mode, to investigate the effect of deformation mode on the wear behavior of NiTi SMA in both martensitic and austenitic states. It was found that, when in martensitic state and under high applied loads, sliding wear mode resulted in more surface damage as compared to that under reciprocating wear mode. When in austenitic state, although similar trends in the coefficient of friction were observed, the coefficient of friction and surface damage in general is less under reciprocating mode than under sliding mode. These observations were further discussed in terms of different deformation mechanisms involved in the wear tests, in particular, the reversibility of martensite variant reorientation and stress-induced phase transformation, respectively.
Locating the origin of stick slip instabilities in sheared granular layers
NASA Astrophysics Data System (ADS)
Korkolis, Evangelos; Niemeijer, André
2017-04-01
Acoustic emission (AE) monitoring is a non-invasive technique widely used to evaluate the state of materials and structures. We have developed a system that can locate the source of AE events associated with unstable sliding (stick-slip) of sheared granular layers during laboratory friction experiments. Our aim is to map the spatial distribution of energy release due to permanent microstructural changes, using AE source locations as proxies. This will allow us to determine the distribution of applied work in a granular medium, which will be useful in developing constitutive laws that describe the frictional behavior of such materials. The AE monitoring system is installed on a rotary shear apparatus. This type of apparatus is used to investigate the micromechanical processes responsible for the macroscopic frictional behavior of granular materials at large shear displacements. Two arrays of 8 piezoelectric sensors each are installed into the ring-shaped steel pistons that confine our samples. The sensors are connected to a high-speed, multichannel oscilloscope that can record full waveforms. The apparatus is also equipped with a system that continuously records normal and lateral (shear) loads and displacements, as well as pore fluid pressure. Thus, we can calculate the frictional and volumetric response of our granular aggregates, as well as the location of AE sources. Here, we report on the results of room temperature experiments on granular aggregates consisting of glass beads or segregated mixtures of glass beads and calcite, at up to 5 MPa normal stress and sliding velocities between 1 and 100 μm/s. Under these conditions, glass beads exhibit unstable sliding behavior accompanied by significant AE activity, whereas calcite exhibits stable sliding and produces no AEs. We recorded a range of unstable sliding behaviors, from fast, regular stick slip at high normal stress (> 4 MPa) and sliding velocities below 20 μm/s, to irregular stick slip at low normal stress or sliding velocities above 20 μm/s. We calculated the source location of each AE associated with significant stress drops (slip events). A very prominent feature, particularly among the large shear displacement experiments, was the development of regions that sustained increased AE activity. Some of these regions remained fixed in space, whereas others kept migrating with increasing shear displacement. We observed that for an arbitrarily small number of consecutive slip events, their associated AEs did not necessarily nucleate in the same region. We believe that the calculated AE source locations reveal the sites where load-bearing microstructures, known as force chains, begin to fail, leading to slip instabilities. The existence of regions of increased AE activity suggests that triggering of force chain failure is controlled to some extent by the loading conditions imposed on the sample by the machine, but may also indicate the lasting influence of previous particle re-organization events on the particles populating these regions.
Relative sliding durability of two candidate high temperature oxide fiber seal materials
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher; Steinetz, Bruce M.
1991-01-01
A test program to determine the relative sliding durability of two candidate ceramic fibers for high temperature sliding seal applications is described. Pin on disk tests were used to evaluate potential seal materials. Friction during the tests and fiber wear, indicated by the extent of fibers broken in a test bundle or yarn, was measured at the end of a test. In general, friction and wear increase with test temperature. This may be due to a reduction in fiber strength, a change in the surface chemistry at the fiber/counterface interface due to oxidation, adsorption and/or desorption of surface species and, to a lesser extent, an increase in counterface surface roughness due to oxidation at elevated temperatures. The relative fiber durability correlates with tensile strength indicating that tensile data, which is more readily available than sliding durability data, may be useful in predicting fiber wear behavior under various conditions. A simple model developed using dimensional analysis shows that the fiber durability is related to a dimensionless parameter which represents the ratio of the fiber strength to the fiber stresses imposed by sliding.
Biofilms inducing ultra-low friction on titanium.
Souza, J C M; Henriques, M; Oliveira, R; Teughels, W; Celis, J-P; Rocha, L A
2010-12-01
Biofilm formation is widely reported in the literature as a problem in the healthcare, environmental, and industrial sectors. However, the role of biofilms in sliding contacts remains unclear. Friction during sliding was analyzed for titanium covered with mixed biofilms consisting of Streptococcus mutans and Candida albicans. The morphology of biofilms on titanium surfaces was evaluated before, during, and after sliding tests. Very low friction was recorded on titanium immersed in artificial saliva and sliding against alumina in the presence of biofilms. The complex structure of biofilms, which consist of microbial cells and their hydrated exopolymeric matrix, acts like a lubricant. A low friction in sliding contacts may have major significance in the medical field. The composition and structure of biofilms are shown to be key factors for an understanding of friction behavior of dental implant connections and prosthetic joints. For instance, a loss of mechanical integrity of dental implant internal connections may occur as a consequence of the decrease in friction caused by biofilm formation. Consequently, the study of the exopolymeric matrix can be important for the development of high-performance novel joint-based systems for medical and other engineering applications.
Raghunath, Vignesh; Braxton, Melissa O.; Gagnon, Stephanie A.; Brunyé, Tad T.; Allison, Kimberly H.; Reisch, Lisa M.; Weaver, Donald L.; Elmore, Joann G.; Shapiro, Linda G.
2012-01-01
Context: Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists’ viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists’ viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists’ viewing strategies and time expenditures in their interpretive workflow. Aims: To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists’ attention and viewing behavior. Settings and Design: Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Materials and Methods: Participants’ foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Statistical Analysis Used: Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists’ accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Results: Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Conclusions: Data detailing mouse cursor movements may be a useful addition to future studies of pathologists’ accuracy and efficiency when using digital pathology. PMID:23372984
Raghunath, Vignesh; Braxton, Melissa O; Gagnon, Stephanie A; Brunyé, Tad T; Allison, Kimberly H; Reisch, Lisa M; Weaver, Donald L; Elmore, Joann G; Shapiro, Linda G
2012-01-01
Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists' viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists' viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists' viewing strategies and time expenditures in their interpretive workflow. To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists' attention and viewing behavior. Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Participants' foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists' accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Data detailing mouse cursor movements may be a useful addition to future studies of pathologists' accuracy and efficiency when using digital pathology.
NASA Astrophysics Data System (ADS)
Tian, K.; Gosvami, N. N.; Goldsby, D. L.; Carpick, R. W.
2015-12-01
Rate and state friction (RSF) laws are empirical relationships that describe the frictional behavior of rocks and other materials in experiments, and reproduce a variety of observed natural behavior when employed in earthquake models. A pervasive observation from rock friction experiments is the linear increase of static friction with the log of contact time, or 'ageing'. Ageing is usually attributed to an increase in real area of contact associated with asperity creep. However, recent atomic force microscopy (AFM) experiments demonstrate that ageing of nanoscale silica-silica contacts is due to progressive formation of interfacial chemical bonds in the absence of plastic deformation, in a manner consistent with the multi-contact ageing behavior of rocks [Li et al., 2011]. To further investigate chemical bonding-induced ageing, we explored the influence of normal load (and thus contact normal stress) and contact time on ageing. Experiments that mimic slide-hold-slide rock friction experiments were conducted in the AFM for contact loads and hold times ranging from 23 to 393 nN and 0.1 to 100 s, respectively, all in humid air (~50% RH) at room temperature. Experiments were conducted by sequentially sliding the AFM tip on the sample at a velocity V of 0.5 μm/s, setting V to zero and holding the tip stationary for a given time, and finally resuming sliding at 0.5 μm/s to yield a peak value of friction followed by a drop to the sliding friction value. Chemical bonding-induced ageing, as measured by the peak friction minus the sliding friction, increases approximately linearly with the product of normal load and the log of the hold time. Theoretical studies of the roles of reaction energy barriers in nanoscale ageing indicate that frictional ageing depends on the total number of reaction sites and the hold time [Liu & Szlufarska, 2012]. We combine chemical kinetics analyses with contact mechanics models to explain our results, and develop a new approach for curve fitting ageing vs. load data which shows that the friction drop data points all fall on a master curve. The analysis yields physically reasonable values for the activation energy and activation volume of the chemical bonding process. Our study provides a basis to hypothesize that the kinetic processes in chemical bonding-induced ageing do not depend strongly on normal load.
Frictional behavior of carbonate-rich incoming sediment in the Hikurangi subduction zone
NASA Astrophysics Data System (ADS)
Rabinowitz, H. S.; Savage, H. M.; Carpenter, B.; Ikari, M.; Collettini, C.
2017-12-01
In recent years, the traditional view of the seismogenic zone has been challenged by observations of a range of seismic behaviors both above and below the depths previously considered capable of nucleating earthquakes. The Hikurangi trench is one of the few subduction zones where this transitional seismic behavior has been observed at the shallowest portions of the subduction zone, providing an opportunity to investigate the mechanical controls on seismic behavior through measurements of directly sampled sediment. To this end, an IODP cruise (March-May, 2018; Exp. 375) will recover sample from the faults that participate in this shallow seismic behavior. In order to obtain preliminary frictional characterization of the sedimentary inputs to the Hikurangi Trench, we conducted deformation experiments on samples from an ocean drill core through the incoming sediments (ODP Site 1124). The sedimentary package subducting at Hikurangi contains carbonate-rich lithologies, which have been shown to be more frictionally unstable (velocity-weakening, high healing rates) than the clays that comprise the majority of the sedimentary inputs to global subduction zones. Such frictional properties could promote seismic behavior in the shallower reaches of the subduction zone. We focus on a section of ODP Site 1124 which has a carbonate content of 40 wt% to investigate the effect of this lithology. Samples were saturated with distilled water mixed with 35 g/l sea salt. Velocity-stepping and slide-hold-slide tests were performed in multiple biaxial and triaxial deformation apparatus to investigate a range of pressures, temperatures and velocities relevant to the shallow subduction zone (σeff = 1-150 MPa, sliding velocities of 1.7 nm/s-300 μm/s, hold times of 1-1000 s, and T = 20-100 ºC). We observe transitions from velocity-strengthening to velocity-weakening behavior over these conditions which could contribute to shallow seismic behavior in the Hikurangi trench.
Towards a numerical run-out model for quick-clay slides
NASA Astrophysics Data System (ADS)
Issler, Dieter; L'Heureux, Jean-Sébastien; Cepeda, José M.; Luna, Byron Quan; Gebreslassie, Tesfahunegn A.
2015-04-01
Highly sensitive glacio-marine clays occur in many relatively low-lying areas near the coasts of eastern Canada, Scandinavia and northern Russia. If the load exceeds the yield stress of these clays, they quickly liquefy, with a reduction of the yield strength and the viscosity by several orders of magnitude. Leaching, fluvial erosion, earthquakes and man-made overloads, by themselves or combined, are the most frequent triggers of quick-clay slides, which are hard to predict and can attain catastrophic dimensions. The present contribution reports on two preparatory studies that were conducted with a view to creating a run-out model tailored to the characteristics of quick-clay slides. One study analyzed the connections between the morphological and geotechnical properties of more than 30 well-documented Norwegian quick-clay slides and their run-out behavior. The laboratory experiments by Locat and Demers (1988) suggest that the behavior of quick clays can be reasonably described by universal relations involving the liquidity index, plastic index, remolding energy, salinity and sensitivity. However, these tests should be repeated with Norwegian clays and analyzed in terms of a (shear-thinning) Herschel-Bulkley fluid rather than a Bingham fluid because the shear stress appears to grow in a sub-linear fashion with the shear rate. Further study is required to understand the discrepancy between the material parameters obtained in laboratory tests of material from observed slides and in back-calculations of the same slides with the simple model by Edgers & Karlsrud (1982). The second study assessed the capability of existing numerical flow models to capture the most important aspects of quick-clay slides by back-calculating three different, well documented events in Norway: Rissa (1978), Finneidfjord (1996) and Byneset (2012). The numerical codes were (i) BING, a quasi-two-dimensional visco-plastic model, (ii) DAN3D (2009 version), and (iii) MassMov2D. The latter two are quasi-three-dimensional codes with a choice of bed-friction laws. The findings of the simulations point strongly towards the need for a different modeling approach that incorporates the essential physical features of quick-clay slides. The major requirement is a realistic description of remolding. A two-layer model is needed to describe the non-sensitive topsoil that often is passively advected by the slide. In many cases, the topography is rather complex so that 3D or quasi-3D (depth-averaged) models are required for realistic modeling of flow heights and velocities. Finally, since many Norwegian quick-clay slides run-out in a fjord (and may generate a tsunami), it is also desirable to explicitly account for buoyancy and hydrodynamic drag.
NASA Astrophysics Data System (ADS)
Wu, Daheng; Ren, Siming; Pu, Jibin; Lu, Zhibin; Zhang, Guangan; Wang, Liping
2018-05-01
The tribological behaviors of hydrogenated DLC film sliding against Al2O3, ZrO2, Si3N4 and WC mating balls have been comparatively investigated by a ball-on-disk tribometer at 150 °C under helium and air (RH = 6%) conditions. The results showed that the mating material influenced the friction and wear behavior remarkably in helium atmosphere, where the wear rates were in inversely proportional to the friction coefficients (COF) of those tribo-pairs. Compared to the tests in helium, the tribological performance of DLC film significantly improved in air. Scanning electron microscope (SEM) and Raman spectroscopy were performed to study the friction behavior and wear mechanism of the film under different conditions. It suggested that the severe abrasion was caused by the strong interaction between the tribo-pairs in helium atmosphere at 150 °C, whereas the sufficient passivation of the dangling bonds of carbon atoms at sliding interface by chemically active molecules, such as water and oxygen, dominated the ultralow friction under air condition. Meanwhile, Hertz analysis was used to further elucidate the frictional mechanism of DLC film under helium and air conditions. It showed that the coefficient of friction was consistent with the varied tendency of the contact radius, namely, higher friction coefficient corresponded to the larger contact radius, which was the same with the relationship between the wear rate and the contact pressure. All of the results made better understanding of the essential mechanism of hydrogenated DLC film sliding against different pairs, which were able to guide the further application of DLC film in the industrial fields of helium atmosphere.
NASA Technical Reports Server (NTRS)
Chang, L.; Hall, P. B.; Thom, R.
1996-01-01
This research reports on an experimental study of the effects of materials and surface roughness on the scuffing characteristics of rolling/sliding contacts cooled and lubricated with liquid oxygen. Experiments were carried out under heavy loading with a Hertzian pressure in the range of 2.0 GPa to 3.0 GPa and with a high rolling velocity of up to 48 m/s. For contacts between AISI 440 C stainless-steel elements, the results showed that the scuffing behavior of the system was fairly consistent under a wide range of rolling velocity. Scuffing commenced at a small slide-to-roll ratio of around 0.02, and the scuffing behavior of the contact was not sensitive to surface roughness for the test-sample RMS roughness ranging from 0.02 microns to 0.10 microns. For contacts between 440 C and Si3N4 elements, on the other hand, the scuffing behavior of the system was not very consistent and somewhat unpredictable. The results were sensitive to surface roughness particularly that of the Si3N4 test sample. With well polished test samples, consistent results were obtained; the level of traction was lower than that with a 440 C toroid and scuffing did not take place up to a slide-to-roll ratio of near 0.03. The results strongly suggest that significant hydrodynamic effect can be generated by liquid oxygen under heavy loading and high velocity conditions. The results also suggest that the hydrodynamic action is likely generated by the conventional viscous mechanism as it can be largely destroyed by a narrow circumferential surface scratch running through the central region of the contact.
NASA Technical Reports Server (NTRS)
Sakurai, T.
1984-01-01
Polymer additives have become requisite for the formulation of multigrade engine oils. The behavior of polymethacrylate (PMA)-thickened oils as lubricants in concentrated contacts under nominal rolling and pure sliding conditions was investigated by conventional optical interferometry. The PMA thickened oils behaved differently from the base oil in the formation of elastohydrodynamic (EHL) films. The higher the elastohydrodynamic molecular weight of the PMA contained in the lubricant, the thinner was the oil film under EHL conditions. The film thickness of shear-degraded PMA-thickened oils was also investigated. The behavior of graphite particles dispersed in both the base oil and the PMA-thickened oil was studied under pure sliding by taking photomicrographs. Many kinds of additives are contained in lubricating oil and the interactions between additives are considered. The interactions of zinc-organodithiophosphates (ZDP) with other additives is discussed.
A Study Of High Speed Friction Behavior Under Elastic Loading Conditions
NASA Astrophysics Data System (ADS)
Crawford, P. J.; Hammerberg, J. E.
2005-03-01
The role of interfacial dynamics under high strain-rate conditions is an important constitutive relationship in modern modeling and simulation studies of dynamic events (<100 μs in length). The frictional behavior occurring at the interface between two metal surfaces under high elastic loading and sliding speed conditions is studied using the Rotating Barrel Gas Gun (RBGG) facility. The RBGG utilizes a low-pressure gas gun to propel a rotating annular projectile towards an annular target rod. Upon striking the target, the projectile imparts both an axial and a torsional impulse into the target. Resulting elastic waves are measured using strain gauges attached to the target rod. The kinetic coefficient of friction is obtained through an analysis of the resulting strain wave data. Experiments performed using Cu/Cu, Cu/Stainless steel and Cu/Al interfaces provide some insight into the kinetic coefficient of friction behavior at varying sliding speeds and impact loads.
Study of Nanoscale Friction Behaviors of Graphene on Gold Substrates Using Molecular Dynamics
NASA Astrophysics Data System (ADS)
Zhu, Pengzhe; Li, Rui
2018-02-01
In this paper, we investigate the friction behaviors of graphene flakes sliding on a gold substrate using molecular dynamics simulations. The effects of flake size, flake shape, relative rotation angle between flake and substrate, and crystal orientation of substrate on the friction process are thoroughly studied. It is found that under the same load, the average friction forces per atom are smaller for a bigger graphene flake, which exhibits an obvious size effect. It is also shown that flake shape is critical in determining the friction in the sliding process. The average friction forces per atom for the square flake are much bigger than those for the triangular and round flakes. Moreover, the average friction forces per atom for the triangular flake are the smallest. We also find that the orientation of graphene flake relative to gold substrate plays a vital role in the friction process. The friction forces for the graphene flake sliding along the armchair direction are much bigger than those for the flakes with rotation. In addition, it is also found that single crystalline gold substrate exhibits a significant anisotropic effect of friction, which is attributed to the anisotropic effect of potential energy corrugation. These understandings not only shed light on the underlying mechanisms of graphene flake sliding on the gold substrates but also may guide the design and fabrication of nanoscale graphene-based devices.
Effect of disjoining pressure on terminal velocity of a bubble sliding along an inclined wall.
Del Castillo, Lorena A; Ohnishi, Satomi; White, Lee R; Carnie, Steven L; Horn, Roger G
2011-12-15
The influence of salt concentration on the terminal velocities of gravity-driven single bubbles sliding along an inclined glass wall has been investigated, in an effort to establish whether surface forces acting between the wall and the bubble influence the latter's mobility. A simple sliding bubble apparatus was employed to measure the terminal velocities of air bubbles with radii ranging from 0.3 to 1.5 mm sliding along the interior wall of an inclined Pyrex glass cylinder with inclination angles between 0.6 and 40.1°. Experiments were performed in pure water, 10 mM and 100 mM KCl solutions. We compared our experimental results with a theory by Hodges et al. which considers hydrodynamic forces only, and with a theory developed by two of us which considers surface forces to play a significant role. Our experimental results demonstrate that the terminal velocity of the bubble not only varies with the angle of inclination and the bubble size but also with the salt concentration, particularly at low inclination angles of ∼1-5°, indicating that double-layer forces between the bubble and the wall influence the sliding behavior. This is the first demonstration that terminal velocities of sliding bubbles are affected by disjoining pressure. Copyright © 2011 Elsevier Inc. All rights reserved.
Tribological investigation of oriented HDPE.
Hoseini, Mohammed; Lausmaa, Jukka; Boldizar, Antal
2002-09-15
The possibility to control the wear properties of high-density polyethylene (HDPE) material at an early processing stage is explored. Wear measurements of cold roll-drawn HDPE with two different draw ratios were carried out for three sliding planes, each in two directions. The dependence of the wear properties on the degree and direction of orientation was investigated. The experiments were performed in a pin-on-disc machine in a dry environment. The tribo-couple consisted of HDPE plates versus a standardised diamond coated steel disc. The results show that the wear resistance of cold roll-drawn HDPE differ widely, by a factor up to 6, depending on the sliding direction relative to the drawing direction. The material has a significantly better wear resistance when the sliding direction was perpendicular to the processing direction. The best wear resistance was in the end plane and it was improved by a factor up to 3.6 when the draw ratio was increased from 2 to 4. These results indicate that molecular orientation by polymer processing is a promising method to improve the wear properties and decrease the wear debris production of HDPE. Copyright 2002 Wiley Periodicals, Inc.
Comparing Sliding-Wear Characteristics of the Electro-Pressure Sintered and Wrought Cobalt
NASA Astrophysics Data System (ADS)
Lee, J. E.; Kim, Y. S.; Kim, T. W.
Dry sliding wear tests of hot-pressure sintered and wrought cobalt were carried out to compare their wear characteristics. Cobalt powders with average size of 1.5µm were electro-pressure sintered to make sintered-cobalt disk wear specimens. A vacuum-induction melted cobalt ingot was hot-rolled at 800°C to a plate, from which wrought-cobalt disk specimens were machined. The specimens were heat treated at various temperatures to vary grain size and phase fraction. Wear tests of the cobalt specimens were carried out using a pin-on-disk wear tester against a glass (83% SiO2) bead at 100N with the constant sliding speed and distance of 0.36m/s and 600m, respectively. Worn surfaces, their cross sections, and wear debris were examined by an SEM. The wear of the cobalt was found to be strongly influenced by the strain-induced phase transformation of ɛ-Co (hcp) to α-Co (fcc). The sintered cobalt had smaller uniform grain size and showed higher wear rate than the wrought cobalt. The higher wear rate of the sintered cobalt was explained by the more active deformation-induced phase transformation than in the wrought cobalt with larger irregular grains.
NASA Astrophysics Data System (ADS)
Prince, M.; Thanu, A. Justin; Gopalakrishnan, P.
2012-04-01
In this investigation, AISI 1020 low carbon steel has been selected as the base material. The Ni based super alloy powder NiCrBSiFeC was sprayed on the base material using high velocity oxy-fuel spraying (HVOF) technique. The thickness of the coating was approximately 0.5 mm (500 μm). The coating was characterized using optical microscopy, Vickers microhardness testing, X-ray diffraction technique and scanning electron microscopy. Dry sliding wear tests were carried out at 3 m/s sliding speed under the load of 10 N for 1000 m sliding distance at various temperatures i.e., 35° C, 250° C and 350° C. The corrosion test was carried out in 1 M copper chloride in acetic acid solution. The polarization studies were also conducted for both base material and coating. The improvement in microhardness from 1.72 GPa (175 HV0.05) to 10.54 GPa (1075 HV0.05) was observed. The coatings exhibited 3-6 times improved wear resistance as compared with base material. Also, the corrosion rate was reduced by 3.5 times due to the presence of coatings.
On the adaptive sliding mode controller for a hyperchaotic fractional-order financial system
NASA Astrophysics Data System (ADS)
Hajipour, Ahamad; Hajipour, Mojtaba; Baleanu, Dumitru
2018-05-01
This manuscript mainly focuses on the construction, dynamic analysis and control of a new fractional-order financial system. The basic dynamical behaviors of the proposed system are studied such as the equilibrium points and their stability, Lyapunov exponents, bifurcation diagrams, phase portraits of state variables and the intervals of system parameters. It is shown that the system exhibits hyperchaotic behavior for a number of system parameters and fractional-order values. To stabilize the proposed hyperchaotic fractional system with uncertain dynamics and disturbances, an efficient adaptive sliding mode controller technique is developed. Using the proposed technique, two hyperchaotic fractional-order financial systems are also synchronized. Numerical simulations are presented to verify the successful performance of the designed controllers.
Prevention of Ovarian High-Grade Serous Carcinoma by Elucidating Its Early Change
2013-10-01
burden of ovarian cancer through prevention. Finally, it is important to note that clear cell, endometrioid and mucinous carcinomas are clinically...were cut onto PEN membrane slides (Leica), and immediately stored on dry ice. An entire cross-section of fallopian tubes for each case underwent LCM...containing BRCA1, BRCA2 and non-BRCA cases, utilizing the following exclusion criteria: o Systemic steroid treatment for other conditions (ie SLE/ankylosing
NASA Astrophysics Data System (ADS)
Sinko, Robert; Vandamme, Matthieu; Bažant, Zdeněk P.; Keten, Sinan
2016-07-01
The Pickett effect is the phenomenon of creep enhancement during transient drying. It has been observed for many nanoporous solids, including concrete, wood and Kevlar. While the existing micromechanical models can partially explain this effect, they have yet to consider nanoscale dynamic effects of water in nanopores, which are believed to be of paramount importance. Here, we examine how creep deformations in a slit pore are accelerated by the motion of water due to drying forces using coarse-grained molecular dynamics simulations. We find that the drying that drives water flow in the nanopores lowers both the activation energy of pore walls sliding past one another and the apparent viscosity of confined water molecules. This lowering can be captured with an analytical Arrhenius relationship accounting for the role of water flow in overcoming the energy barriers. Notably, we use this model and simulation results to demonstrate that the drying creep strain is not linearly dependent on the applied creep stress at the nanopore level. Our findings establish the scaling relationships that explain how the creep driving force, drying force and fluid properties are related. Thus, we establish the nanoscale origins of the Pickett effect and provide strategies for minimizing the additional displacements arising from this effect.
Sinko, Robert; Vandamme, Matthieu; Keten, Sinan
2016-01-01
The Pickett effect is the phenomenon of creep enhancement during transient drying. It has been observed for many nanoporous solids, including concrete, wood and Kevlar. While the existing micromechanical models can partially explain this effect, they have yet to consider nanoscale dynamic effects of water in nanopores, which are believed to be of paramount importance. Here, we examine how creep deformations in a slit pore are accelerated by the motion of water due to drying forces using coarse-grained molecular dynamics simulations. We find that the drying that drives water flow in the nanopores lowers both the activation energy of pore walls sliding past one another and the apparent viscosity of confined water molecules. This lowering can be captured with an analytical Arrhenius relationship accounting for the role of water flow in overcoming the energy barriers. Notably, we use this model and simulation results to demonstrate that the drying creep strain is not linearly dependent on the applied creep stress at the nanopore level. Our findings establish the scaling relationships that explain how the creep driving force, drying force and fluid properties are related. Thus, we establish the nanoscale origins of the Pickett effect and provide strategies for minimizing the additional displacements arising from this effect. PMID:27493584
Sinko, Robert; Vandamme, Matthieu; Bažant, Zdeněk P; Keten, Sinan
2016-07-01
The Pickett effect is the phenomenon of creep enhancement during transient drying. It has been observed for many nanoporous solids, including concrete, wood and Kevlar. While the existing micromechanical models can partially explain this effect, they have yet to consider nanoscale dynamic effects of water in nanopores, which are believed to be of paramount importance. Here, we examine how creep deformations in a slit pore are accelerated by the motion of water due to drying forces using coarse-grained molecular dynamics simulations. We find that the drying that drives water flow in the nanopores lowers both the activation energy of pore walls sliding past one another and the apparent viscosity of confined water molecules. This lowering can be captured with an analytical Arrhenius relationship accounting for the role of water flow in overcoming the energy barriers. Notably, we use this model and simulation results to demonstrate that the drying creep strain is not linearly dependent on the applied creep stress at the nanopore level. Our findings establish the scaling relationships that explain how the creep driving force, drying force and fluid properties are related. Thus, we establish the nanoscale origins of the Pickett effect and provide strategies for minimizing the additional displacements arising from this effect.
Effect of oxygen, methyl mercaptan, and methyl chloride on friction behavior of copper-iron contacts
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1978-01-01
Sliding friction experiments were conducted with an iron rider on a copper disk and a copper rider on an iron disk. The sputter cleaned iron and copper disk surfaces were saturated with oxygen, methyl mercaptan, and methyl chloride at atmospheric pressure. Auger emission spectroscopy was used to monitor the surfaces. Lower friction was obtained in all experiments with the copper rider sliding on the iron disk than when the couple was reversed. For both iron and copper disks, methyl mercaptan gave the best surface coverage and was most effective in reducing friction. For both iron and copper disks, methyl chloride was the least effective in reducing friction. With sliding, copper transferred to iron and iron to copper.
Fading to increase heterosexual responsiveness in homosexuals1
Barlow, David H.; Agras, W. Stewart
1973-01-01
Heterosexual responsiveness, measured by penile responses and reports of behavior, was strengthened in three homosexuals through a fading procedure. Using two slide projectors, colored slides of nude females were superimposed on colored slides of nude males. As the sexual response was emitted, the nude male was faded out and the nude female faded in. Heterosexual arousal decreased when the fading procedure was reversed or stopped and increased once again when fading was resumed. Homosexual arousal remained high during this experiment but had decreased in two subjects at follow-up. The results suggest that fading was responsible for altering stimulus control of sexual arousal and that aversive techniques may not be necessary in the treatment of sexual deviation. ImagesFig. 1 PMID:16795417
Oosawa, Fumio
2008-04-25
Various myosin-actin systems do not always show the same sliding behaviors. To make the situation clear, discussions are concentrated on the unit event of sliding of the chemo-mechanical enzyme composed of a single myosin head and a single actin filament with regulatory proteins. The popular idea of the one-to-one correspondence between the chemical state and the physical state or between the chemical reaction step and the physical conformational change is reexamined. It is likely that the sites and the modes of interaction between myosin head and actin filament during the ATP hydrolysis are more multiple and variable, and the input-output coupling in the chemo-mechanical enzyme is loose.
NASA Astrophysics Data System (ADS)
Guo, Qing-chun; Zhou, Hong; Wang, Cheng-tao; Zhang, Wei; Lin, Peng-yu; Sun, Na; Ren, Luquan
2009-04-01
Stimulated by the cuticles of soil animals, an attempt to improve the wear resistance of compact graphite cast iron (CGI) with biomimetic units on the surface was made by using a biomimetic coupled laser remelting process in air and various thicknesses water film, respectively. The microstructures of biomimetic units were examined by scanning electron microscope and X-ray diffraction was used to describe the microstructure and identify the phases in the melted zone. Microhardness was measured and the wear behaviors of biomimetic specimens as functions of different mediums as well as various water film thicknesses were investigated under dry sliding condition, respectively. The results indicated that the microstructure zones in the biomimetic specimens processed with water film are refined compared with that processed in air and had better wear resistance increased by 60%, the microhardness of biomimetic units has been improved significantly. The application of water film provided finer microstructures and much more regular grain shape in biomimetic units, which played a key role in improving the friction properties and wear resistance of CGI.
NASA Astrophysics Data System (ADS)
Yao, Jianhua; Zhang, Jie; Wu, Guolong; Wang, Liang; Zhang, Qunli; Liu, Rong
2018-05-01
The distribution of WC particles in laser cladded composite coatings can significantly affect the wear resistance of the coatings under aggressive environments. In this study, pre-alloyed WC-NiCrMo powder is deposited on SS316L via laser cladding with circular spot and wide-band spot, respectively. The microstructure and WC distribution of the coatings are investigated with optical microscope (OM), scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), and X-ray diffraction (XRD). The wear behavior of the coatings is investigated under dry sliding-wear test. The experimental results show that the partially dissolved WC particles are uniformly distributed in both coatings produced with circular spot and wide-band spot, respectively, and the microstructures consist of WC and M23C6 carbides and γ-(Ni, Fe) solid solution matrix. However, due to Fe dilution, the two coatings have different microstructural characteristics, resulting in different hardness and wear resistance. The wide-band spot laser prepared coating shows better performance than the circular spot laser prepared coating.
Instabilities in dynamic anti-plane sliding of an elastic layer on a dissimilar elastic half-space
NASA Astrophysics Data System (ADS)
Kunnath, R.
2012-12-01
The stability of dynamic anti-plane sliding at an interface between an elastic layer and an elastic half-space with dissimilar elastic properties is studied. Friction at the interface is assumed to follow a rate- and state-dependent law, with a positive instantaneous dependence on slip velocity and a rate weakening behavior in the steady state. The perturbations are of the form exp(ikx+pt), where k is the wavenumber, x is the coordinate along the interface, p is the time response to the perturbation and t is time. The results of the stability analysis are shown in Figs. 1 and 2 with the velocity weakening parameter b/a=5, shear wave speed ratio cs'/cs=1.2, shear modulus ratio μ'/μ=1.2 and non-dimensional layer thickness H=100. The normalized instability growth rate and normalized phase velocity are plotted as a function of wavenumber. Fig.1 is for a non-dimensional unperturbed slip velocity ɛ=5 (rapid sliding) while Fig. 2 is for ɛ=0.05 (slow sliding). The results show the destabilization of interfacial waves. For slow sliding, destabilization of interfacial waves is still seen, indicating that the quasi-static approximation to slow sliding is not valid. This is in agreement with the result of Ranjith (Int. J. Solids and Struct., 2009, 46, 3086-3092) who predicted an instability of long-wavelength Love waves in slow sliding.
Thermomechanical Contact Phenomena and Wear of Sliding Components
1989-07-31
seals. Many of those methods were used in this study. • • I I i II I I I I I I I l1 2. METHDS Sliding wear tests were conducted on Inconel 625 seal rings...wear. These coatings have been used successfully in reducing the wear of machine tools , aircraft and automobile engine parts, etc. It is only recently...scanning electron microscopy were tools employed to determine the wear behavior and wear mechanism associated with the various chromium carbide and tungsten
An analysis of the sliding pressure start-up of SCWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, F.; Yang, J.; Li, H.
In this paper, the preliminary sliding pressure start-up system and scheme of supercritical water-cooled reactor in CGNPC (CGN-SCWR) were proposed. Thermal-hydraulic behavior in start-up procedures was analyzed in detail by employing advanced reactor subchannel analysis software ATHAS. The maximum cladding temperature (MCT for short) and core power of fuel assembly during the whole start-up process were investigated comparatively. The results show that the recommended start-up scheme meets the design requirements from the perspective of thermal-hydraulic. (authors)
Plasma Assisted Decontamination of Bacterial Spores
Kuo, Spencer P
2008-01-01
The efficacy and mechanism of killing bacterial spores by a plasma torch is studied. Bacterial-spore (Bacillus cereus) suspension is inoculated onto glass/paper slide-coupons and desiccated into dry samples, and inoculated into well-microplate as wet sample. The exposure distance of all samples is 4 cm from the nozzle of the torch. In the experiment, paper slide-coupon is inserted inside an envelope. The kill times on spores in three types of samples are measured to be about 3, 9, and 24 seconds. The changes in the morphology and shape of still viable spores in treated wet samples are recorded by scanning electron and atomic force microscopes. The loss of appendages and exosporium in the structure and squashed/flattened cell shape are observed. The emission spectroscopy of the torch indicates that the plasma effluent carries abundant reactive atomic oxygen, which is responsible for the destruction of spores. PMID:19662115
Numerical Studies of Friction Between Metallic Surfaces and of its Dependence on Electric Currents
NASA Astrophysics Data System (ADS)
Meintanis, Evangelos; Marder, Michael
2009-03-01
We will present molecular dynamics simulations that explore the frictional mechanisms between clean metallic surfaces. We employ the HOLA molecular dynamics code to run slider-on-block experiments. Both objects are allowed to evolve freely. We recover realistic coefficients of friction and verify the importance of cold-welding and plastic deformations in dry sliding friction. We also find that plastic deformations can significantly affect both objects, despite a difference in hardness. Metallic contacts have significant technological applications in the transmission of electric currents. To explore the effects of the latter to sliding, we had to integrate an electrodynamics solver into the molecular dynamics code. The disparate time scales involved posed a challenge, but we have developed an efficient scheme for such an integration. A limited electrodynamic solver has been implemented and we are currently exploring the effects of currents in the friction and wear of metallic contacts.
Deformation relief evolution during sliding friction of Hadfield steel single crystal
NASA Astrophysics Data System (ADS)
Lychagin, D. V.; Filippov, A. V.; Novitskaya, O. S.; Kolubaev, A. V.; Sizova, O. V.
2017-12-01
The paper deals with the evolution of the deformation relief formed on lateral faces of single crystals of Hadfield steel during dry sliding friction. The use of single crystals with the predetermined orientation enables to analyze the development of shear systems subject to the duration of tribological tests. As the test duration increases, slip bands are curved and thicken in the near-surface region. After 24 hours of friction, single crystals of Hadfield steel demonstrate the maximum hardening. Afterwards, the wear process begins, which is followed by the repeated strain hardening of the specimens. After 48 hours of friction, the height of the deformation relief nearly halves on all of the three faces, as compared to that observed after 24 hours of friction. Differences in the propagation height of slip bands on the faces occur due to the uneven running-in as well as the complex involvement pattern of shear systems into the deformation process.
Effect of shrinkage on isothermal drying behavior of 2-phase olive mill waste
USDA-ARS?s Scientific Manuscript database
The objective of this study was to determine the drying behavior of 2-phase olive mill waste (2POMW) under isothermal microwave-convection drying conditions. 2POMW samples were dried in a thin layer in a variable-power pilot microwave oven with impinging air, using a feedback controller to maintain...
NASA Astrophysics Data System (ADS)
Rani Rana, Sandhya; Pattnaik, A. B.; Patnaik, S. C.
2018-03-01
In the present work the wear behavior and mechanical properties of as cast A16082 and A16086-T6 were compared and analyzed using statistical analysis. The as cast Al6082 alloy was solutionized at 550°C, quenched and artificially aged at 170°C for 8hrs. Metallographic examination and XRD analysis revealed the presence of intermetallic compounds Al6Mn.Hardness of heat treated Al6082 was found to be more than as cast sample. Wear tests were carried out using Pin on Disc wear testing machine according to Taguchi L9 orthogonal array. Experiments were conducted under normal load 10-30N, sliding speed 1-3m/s, sliding distance 400,800,1200m respectively. Sliding speed was found to be the dominant factor for wear in both as cast and aged Al 6082 alloy. Sliding distance increases the wear rate up to 800m and then after it decreases.
NASA Astrophysics Data System (ADS)
Ding, Da-Wei; Liu, Fang-Fang; Chen, Hui; Wang, Nian; Liang, Dong
2017-12-01
In this paper, a simplest fractional-order delayed memristive chaotic system is proposed in order to control the chaos behaviors via sliding mode control strategy. Firstly, we design a sliding mode control strategy for the fractional-order system with time delay to make the states of the system asymptotically stable. Then, we obtain theoretical analysis results of the control method using Lyapunov stability theorem which guarantees the asymptotic stability of the non-commensurate order and commensurate order system with and without uncertainty and an external disturbance. Finally, numerical simulations are given to verify that the proposed sliding mode control method can eliminate chaos and stabilize the fractional-order delayed memristive system in a finite time. Supported by the National Nature Science Foundation of China under Grant No. 61201227, Funding of China Scholarship Council, the Natural Science Foundation of Anhui Province under Grant No. 1208085M F93, 211 Innovation Team of Anhui University under Grant Nos. KJTD007A and KJTD001B
van Goozen, Stephanie H M; Cohen-Kettenis, Peggy T; Matthys, Walter; van Engeland, Herman
2002-06-01
Children with disruptive behavior disorders (DBD) have poor social skills and show aggressive interaction patterns. There is evidence from prospective studies of an association between early physical abuse, later social information-processing patterns, and aggressive behavior. A pattern of hypervigilance to hostile cues has been found in DBD children, but very few studies have investigated encoding or perceptual preference for specific classes of stimuli. Some DBD children have a suspected history of sexual abuse and a few have themselves been sexually offensive. Our belief that the sexuality of DBD children should be investigated raised the issue of how to go about doing this. A procedure was developed in which we measured the relative preference for sexual and aggressive stimuli in comparison to other stimulus categories, and the data of DBD children were compared with those of normal controls. It was found that DBD children preferred viewing sexual slides and had a lower preference for nonaggressive slides. Furthermore, boys in general preferred viewing aggressive slides, did so for longer, and chose them earlier, whereas the more aggressive DBD children distinguished themselves in selecting aggressive stimuli earlier. The implications of these findings were discussed and it was concluded that sexuality is clearly an important topic to address in aggressive children in general and not only in the abused ones.
Stress relaxation at a gelatin hydrogel-glass interface in direct shear sliding
NASA Astrophysics Data System (ADS)
Gupta, Vinit; Singh, Arun K.
2018-01-01
In this paper, we study experimentally the stress relaxation behavior of soft solids such as gelatin hydrogels on a smooth glass surface in direct shear sliding. It is observed experimentally that irrespective of pulling velocity, the sliding block relaxes to the same level of nonzero residual stress. However, residual stress increases with increasing gelatin concentration in the hydrogels. We have also validated a friction model for strong bond formation during steady relaxation in light of the experimental observations. Our theoretical analysis establishes that population of dangling chains at the sliding interface significantly affects the relaxation process. As a result, residual stress increases with increasing gelatin concentration or decreasing mesh size of the three-dimensional structures in the hydrogels. It is also found that the transition time, at which a weak bond converts to strong bond, increases with increasing mesh size of the hydrogels. Moreover, relaxation time constant of a strong bond decreases with increasing mesh size. However, activation length of a strong bond increases with mesh size. Finally, this study signifies the role of residual strength in frictional shear sliding and it is believed that these results should be useful to understand the role of residual stress in stick-slip instability.
NASA Astrophysics Data System (ADS)
Lipovsky, Bradley Paul; Dunham, Eric M.
2017-04-01
The Whillans Ice Plain (WIP), Antarctica, experiences twice daily tidally modulated stick-slip cycles. Slip events last about 30 min, have sliding velocities as high as ˜0.5 mm/s (15 km/yr), and have total slip ˜0.5 m. Slip events tend to occur during falling ocean tide: just after high tide and just before low tide. To reproduce these characteristics, we use rate-and-state friction, which is commonly used to simulate tectonic faulting, as an ice stream sliding law. This framework describes the evolving strength of the ice-bed interface throughout stick-slip cycles. We present simulations that resolve the cross-stream dimension using a depth-integrated treatment of an elastic ice layer loaded by tides and steady ice inflow. Steady sliding with rate-weakening friction is conditionally stable with steady sliding occurring for sufficiently narrow ice streams relative to a nucleation length. Stick-slip cycles occur when the ice stream is wider than the nucleation length or, equivalently, when effective pressures exceed a critical value. Ice streams barely wider than the nucleation length experience slow-slip events, and our simulations suggest that the WIP is in this slow-slip regime. Slip events on the WIP show a sense of propagation, and we reproduce this behavior by introducing a rate-strengthening region in the center of the otherwise rate-weakening ice stream. If pore pressures are raised above a critical value, our simulations predict that the WIP would exhibit quasi-steady tidally modulated sliding as observed on other ice streams. This study validates rate-and-state friction as a sliding law to describe ice stream sliding styles.
Effect of disjoining pressure on terminal velocity of a bubble sliding along an inclined wall
Del Castillo, Lorena A.; Ohnishi, Satomi; White, Lee R.; Carnie, Steven L.; Horn, Roger G.
2011-01-01
The influence of salt concentration on the terminal velocities of gravity-driven single bubbles sliding along an inclined glass wall has been investigated, in an effort to establish whether surface forces acting between the wall and the bubble influence the latter’s mobility. A simple sliding bubble apparatus was employed to measure the terminal velocities of air bubbles with radii ranging from 0.3 to 1.5 mm sliding along the interior wall of an inclined Pyrex glass cylinder with inclination angles between 0.6 and 40.1°. Experiments were performed in pure water, 10 mM and 100 mM KCl solutions. We compared our experimental results with a theory by Hodges et al. [1] which considers hydrodynamic forces only, and with a theory developed by two of us [2] which considers surface forces to play a significant role. Our experimental results demonstrate that the terminal velocity of the bubble not only varies with the angle of inclination and the bubble size but also with the salt concentration, particularly at low inclination angles of ∼1–5°, indicating that double-layer forces between the bubble and the wall influence the sliding behavior. This is the first demonstration that terminal velocities of sliding bubbles are affected by disjoining pressure. PMID:21924429
Atomistic Simulation of Single Asperity Contact
NASA Astrophysics Data System (ADS)
Philip; Kromer; Marder, Michael
2003-03-01
In the standard (Bowden and Tabor) model of friction, the macroscopic behavior of sliding results from the deformation of microscopic asperities in contact. A recent idea instead extracts macroscopic friction from the aggregate behavior of traveling, self-healing interfacial cracks: certain families of cracks are found to be mathematically forbidden, and the envelope of allowed cracks dictates the familiar Coulomb law of friction. To explore the connection between the new and traditional pictures of friction, we conducted molecular dynamics (MD) simulations of single-asperity contact subjected to an oscillatory sliding force -- a geometry important for the problem of fretting (damage due to small-scale vibratory contact). Our simulations reveal the importance of traveling interface cracks to the dynamics of slip at the interface, and illuminate the dynamics of crack initiation and suppression.
Nonequilibrium Chromosome Looping via Molecular Slip Links
NASA Astrophysics Data System (ADS)
Brackley, C. A.; Johnson, J.; Michieletto, D.; Morozov, A. N.; Nicodemi, M.; Cook, P. R.; Marenduzzo, D.
2017-09-01
We propose a model for the formation of chromatin loops based on the diffusive sliding of molecular slip links. These mimic the behavior of molecules like cohesin, which, along with the CTCF protein, stabilize loops which contribute to organizing the genome. By combining 3D Brownian dynamics simulations and 1D exactly solvable nonequilibrium models, we show that diffusive sliding is sufficient to account for the strong bias in favor of convergent CTCF-mediated chromosome loops observed experimentally. We also find that the diffusive motion of multiple slip links along chromatin is rectified by an intriguing ratchet effect that arises if slip links bind to the chromatin at a preferred "loading site." This emergent collective behavior favors the extrusion of loops which are much larger than the ones formed by single slip links.
Elastomers in Combined Rolling-Sliding Contact; Wear and its Underlying Mechanisms
NASA Astrophysics Data System (ADS)
Rowe, Kyle Gene
Elastomeric materials, specifically rubbers, being both of a practical and scientific importance, have been the subjects of vast amounts of research spanning well over two centuries. There is currently a large effort by tire manufacturers to design new rubber compounds with lower rolling resistance, higher sliding friction, and reduced or predictable wear. At present, these efforts are primarily based on a few empirical rules and very costly trial and error testing; only a basic understanding of the mechanisms involved in the wear of elastomeric materials exists despite rigorous study. In general, the only well controlled experiments have been for simple loading and sliding schemes. The aim of this work is to characterize the tribological properties of a carbon black filled natural rubber sample. This work explores (1) its behavior in unidirectional sliding, (2) contact mechanics, (3) traction properties in combined rolling and sliding, (4) frictional heating response, and (5) wear. It was found that the friction coefficient of this material was dependent upon sliding velocity, contact pressure, and surface roughness. The high friction coefficients also lead to a bifurcation of the contact area into two different pressure regimes at sliding velocities greater than 10 mm/s . The traction response of this material in combined rolling and sliding exhibited similar behavior, being a function of the contact pressure, but not rolling velocity. The wear of this material was found to be linearly dependent upon the global slip condition and occurred preferentially on the sample. Investigations of the worn surface revealed that the most likely mechanism of wear is the degradation of surface material in a confined layer a few micrometers thick. A simple spring-mass model was developed to offer an explanation of localized wear. It was found that the coupling of system elements in the normal direction helped to shift the load from wearing elements to non-wearing ones. The result was a rapid and localized recession of material, driven by certain key system parameters such as wear rate, material stiffness, and friction. The system was also found to be sensitive to variability within these parameters, but to a lesser degree. This work demonstrates that laboratory scale tribological testing of elastomers can provide conclusive and repeatable results without recourse to macro-scale trials and experiments. The data and insights provided can be used as a tool for understanding the many contributions of materials and fillers on the friction and wear of elastomers, and in design and wear life predictions as well.
Nuclear behavior during basidiospore germination in Cronartium quercuum f. sp. fusiforme
P.C. Spaine; Shigeru Kaneko
1996-01-01
Nuclear behavior during basidiospore germination in Cronartiunz quercuum f. sp. fusiforme was examined on glass slides and host seedlings using 4,6-diamidino-2-phenylindolestaining. Mononucleate basidiospores of Cronartium quercuum f. sp. fusiforme normally were produced following meiosis in the teliospore. However, a subsequent mitotic division often occurred within...
NASA Astrophysics Data System (ADS)
Korshunov, L. G.; Chernenko, N. L.
2016-03-01
The effect of plastic deformation that occurs in the zone of the sliding friction contact on structural transformations in the 12Kh18N9T austenitic steel subjected to subsequent 1-h oxidation in air at temperatures of 300-800°C, as well as on its wear resistance, has been studied. It has been shown that severe deformation induced by dry sliding friction produces the two-phase nanocrystalline γ + α structure in the surface layer of the steel ~10 μm thick. This structure has the microhardness of 5.2 GPa. Subsequent oxidation of steel at temperatures of 300-500°C leads to an additional increase in the microhardness of its deformed surface layer to the value of 7.0 GPa. This is due to the active saturation of the austenite and the strain-assisted martensite (α') with the oxygen atoms, which diffuse deep into the metal over the boundaries of the γ and α' nanocrystals with an increased rate. The concentration of oxygen in the surface layer of the steel and in wear products reaches 8 wt %. The atoms of the dissolved oxygen efficiently pin dislocations in the γ and α' phases, which enhances the strength and wear resistance of the surface of the 12Kh18N9T steel. The oxidation of steel at temperatures of 550-800°C under a light normal load (98 N) results in the formation of a large number of Fe3O4 (magnetite) nanoparticles, which increase the resistance of the steel to thermal softening and its wear resistance during dry sliding friction in a pair with 40Kh13 steel. Under a heavy normal load (196 N), the toughness of 12Kh18N9T steel and, therefore, the wear resistance of its surface layer decrease due to the presence of the brittle oxide phase.
Methods for assessing the stability of slopes during earthquakes-A retrospective
Jibson, R.W.
2011-01-01
During the twentieth century, several methods to assess the stability of slopes during earthquakes were developed. Pseudostatic analysis was the earliest method; it involved simply adding a permanent body force representing the earthquake shaking to a static limit-equilibrium analysis. Stress-deformation analysis, a later development, involved much more complex modeling of slopes using a mesh in which the internal stresses and strains within elements are computed based on the applied external loads, including gravity and seismic loads. Stress-deformation analysis provided the most realistic model of slope behavior, but it is very complex and requires a high density of high-quality soil-property data as well as an accurate model of soil behavior. In 1965, Newmark developed a method that effectively bridges the gap between these two types of analysis. His sliding-block model is easy to apply and provides a useful index of co-seismic slope performance. Subsequent modifications to sliding-block analysis have made it applicable to a wider range of landslide types. Sliding-block analysis provides perhaps the greatest utility of all the types of analysis. It is far easier to apply than stress-deformation analysis, and it yields much more useful information than does pseudostatic analysis. ?? 2010.
Steve L. Voelker; R. Justin DeRose; Matthew F. Bekker; Chalita Sriladda; Nisa Leksungnoen; Roger K. Kjelgren
2018-01-01
Conifers in the Pinaceae and Cupressaceae from dry environments have been shown to broadly differ in their stomatal sensitivity to soil drying that result in isohydric versus anisohydric water use behavior, respectively. Here, we first employ a series of drought experiments and field observations to confirm the degree of isohydric versus anisohydric water use behavior...
Space Flight Resource Management for ISS Operations
NASA Technical Reports Server (NTRS)
Schmidt, Larry; Slack, Kelley; O'Keefe, William; Huning, Therese; Sipes, Walter; Holland, Albert
2011-01-01
This slide presentation reviews the International Space Station (ISS) Operations space flight resource management, which was adapted to the ISS from the shuttle processes. It covers crew training and behavior elements.
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Buckley, D. H.
1983-01-01
An investigation was conducted to examine the microstructure and surface chemistry of amorphous alloys, and their effects on tribological behavior. The results indicate that the surface oxide layers present on amorphous alloys are effective in providing low friction and a protective film against wear in air. Clustering and crystallization in amorphous alloys can be enhanced as a result of plastic flow during the sliding process at a low sliding velocity, at room temperature. Clusters or crystallines with sizes to 150 nm and a diffused honeycomb-shaped structure are produced on the wear surface. Temperature effects lead to drastic changes in surface chemistry and friction behavior of the alloys at temperatures to 750 C. Contaminants can come from the bulk of the alloys to the surface upon heating and impart to the surface oxides at 350 C and boron nitride above 500 C. The oxides increase friction while the boron nitride reduces friction drastically in vacuum.
Preparation and mounting of adult Drosophila structures in Canada balsam.
Stern, David L; Sucena, Elio
2012-03-01
The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. To prepare fine "museum-quality," permanent slides, it is best to mount specimens in Canada Balsam. It is difficult to give precise recipes for Canada Balsam, because every user seems to prefer a slightly different viscosity. Dilute solutions spread easily and do not dry too rapidly while mounting specimens. The disadvantage is that there is actually less Balsam in a "drop" of the solution, and when dried, it can contract from the sides of the coverslip, sometimes disturbing the specimen. Unfortunately, there is no substitute for experience when using Canada Balsam. This protocol describes a procedure for mounting adult cuticles in Canada Balsam.
Ancient pathogens in museal dry bone specimens: analysis of paleocytology and aDNA.
Gaul, Johanna Sophia; Winter, Eduard; Grossschmidt, Karl
2015-04-01
Bone samples investigated in this study derive from the pathologic-anatomical collection of the Natural History Museum of Vienna. In order to explore the survival of treponemes and treponemal ancient DNA in museal dry bone specimens, we analyzed three individuals known to have been infected with Treponema pallidum pallidum. No reproducible evidence of surviving pathogen's ancient DNA (aDNA) was obtained, despite the highly sensitive extraction and amplification techniques (TPP15 and arp). Additionally, decalcification fluid of bone sections was smear stained with May-Gruenwald-Giemsa. The slides were examined using direct light microscope and dark field illumination. Remnants of spirochetal structures were detectable in every smear. Our results demonstrate that aDNA is unlikely to survive, but spirochetal remains are stainable and thus detectable.
[Study on Xinyueshu spray drying assisted with copovidone and its effect on powder property].
Jiang, Yan-Rong; Zhang, Zhen-Hai; Ding, Dong-Mei; Yan, Hong-Mei; Hu, Shao-Ying; Jia, Xiao-Bin
2013-12-01
To study the application characteristics of copovidone (PVP-S630) in Xinyueshu extracts during the spray drying process, and its effect on such pharmaceutical properties as micromeritics and drug release behavior. PVP-S630 was added into Xinyueshu extracts to study on the spray drying, the effect of different dosages of PVP-S630 against the wall sticking effect of the spray drying, as well as the power property of Xinyueshu spray drying power and the dissolution in vitro behavior of the effective component of hyperoside. The results showed that PVP-S630 revealed a significant anti-wall sticking effect, with no notable change in the grain size of the spray drying power, increase in the fluidity, improvement in the moisture absorption and remarkable rise in the dissolution in vitro behavior of hyperoside. It was worth further studying the application of PVP-S630 in spray drying power of traditional Chinese medicine.
Tribological characteristics of nitrogen (N+) implanted iron
NASA Technical Reports Server (NTRS)
Jones, W. R.; Ferrante, J.
1982-01-01
The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed.
Studies of Contaminated Runways,
1980-01-01
slide friction we refer to the friction which is produced due to the relative motion between a rubber tyre and a hard runway. tThis type of friction is... rubber planing" and a tyre exposed to such a process shows damages in form of a local sticky surface or a locally worn-off layer. The steam, which...macrostructure causes when dry together with a rubber tyre brake numbers Prom 0.7 to 1.1 depending on the rubber mixture and inflation pressure. On this type of
2014-04-15
the floor on which the platform is dropped upon. Alternatively, a base excitation can be provided to the sliding platform in the upward vertical...7ms clips of chest resultant acceleration, (7) 7ms clip of pelvic vertical acceleration, (8,9) Peak and 30ms clips of lumbar spine compression, and...10) Pelvic vertical Dynamic Response Index (DRI)[12]. The sample size for each of the three seating variants consisted of 230 MADYMO
Finite Element Simulation Methods for Dry Sliding Wear
2008-03-27
effects of wear only occur on a microscopic level (3; 14; 17). A third reason that wear is not well understood is that it involves many different...material or one with a higher coefficient of friction there will be more of a problem with high pressure points. A third possibility is to spread the...For the local model the rail is modeled as a deformable body , and a small, 1 mm, square is taken from the slipper as the submodel. 5.2 The Global
2014-06-02
thick-walled glass reactors fitted with ACE-threads under an argon atmosphere. The reactors were dried under vacuum then refilled with argon five times...were settled in individual dishes containing 10 ml of suspension at ~20°C on the laboratory benches. After 2 h the slides were exposed to a submerged ...and D20). This was done in order to see how the surfaces rearranged themselves after prolonged periods submerged in water, as would be the case on
Wear Behaviour of Al-6061/SiC Metal Matrix Composites
NASA Astrophysics Data System (ADS)
Mishra, Ashok Kumar; Srivastava, Rajesh Kumar
2017-04-01
Aluminium Al-6061 base composites, reinforced with SiC particles having mesh size of 150 and 600, which is fabricated by stir casting method and their wear resistance and coefficient of friction has been investigated in the present study as a function of applied load and weight fraction of SiC varying from 5, 10, 15, 20, 25, 30, 35 and 40 %. The dry sliding wear properties of composites were investigated by using Pin-on-disk testing machine at sliding velocity of 2 m/s and sliding distance of 2000 m over a various loads of 10, 20 and 30 N. The result shows that the reinforcement of the metal matrix with SiC particulates up to weight percentage of 35 % reduces the wear rate. The result also show that the wear of the test specimens increases with the increasing load and sliding distance. The coefficient of friction slightly decreases with increasing weight percentage of reinforcements. The wear surfaces are examined by optical microscopy which shows that the large grooved regions and cavities with ceramic particles are found on the worn surface of the composite alloy. This indicates an abrasive wear mechanism, which is essentially a result of hard ceramic particles exposed on the worn surfaces. Further, it was found from the experimentation that the wear rate decreases linearly with increasing weight fraction of SiC and average coefficient of friction decreases linearly with increasing applied load, weight fraction of SiC and mesh size of SiC. The best result has been obtained at 35 % weight fraction and 600 mesh size of SiC.
Experimental and analytical tools for evaluation of Stirling engine rod seal behavior
NASA Technical Reports Server (NTRS)
Krauter, A. I.; Cheng, H. S.
1979-01-01
The first year of a two year experimental and analytical program is reported. The program is directed at the elastohydrodynamic behavior of sliding elastomeric rod seals for the Stirling engine. During the year, experimental and analytical tools were developed for evaluating seal leakage, seal friction, and the fluid film thickness at the seal/cylinder interface.
Motor Behavior: From Telegraph Keys and Twins to Linear Slides and Stepping
ERIC Educational Resources Information Center
Thomas, Jerry R.
2006-01-01
Motor behavior is a significant area of scholarship with 64 Fellows from the American Academy of Kinesiology and Physical Education engaged in that work since 1930. This paper provides a brief overview of the history of research in motor development and motor control/learning, particularly noting the contributions to scholarship of Academy…
Desmoplastic melanoma morphology on Thinprep: a report of two cases
Van Ells, Becky L; Madory, James E; Hoda, Rana S
2007-01-01
Background Desmoplastic melanoma is a variant of malignant melanoma that can range in appearance from sarcomatoid to scar-like. Cytomorphology of desmoplastic melanoma has been previously described on conventional smears; however, to our knowledge, detailed cytomorphology on ThinPrep has so far not been described. Herein, we describe the cytomorphology of two cases of desmoplastic melanoma on fine needle aspiration processed as ThinPrep slides and compare it to that seen on conventional smears. Pertinent immunocytochemical stains, performed on ThinPrep slides are also discussed. Case presentation The first case is a woman with a history of desmoplastic melanoma of the scalp with previous local recurrences and lymph node metastasis with a new submandibular mass. The second case is a man with a previously resected desmoplastic melanoma with his first local recurrence. Conventional smears, including air-dried Diff-Quik-stained and alcohol-fixed Papanicolaou-stained smears, demonstrated aggregates of pleomorphic spindle cells admixed with fibrous stroma and single spindle cells. In both cases, nuclei were elongated and plump with irregular nuclear contours, deep grooves, and folds. Chromatin was dark and coarse with either inconspicuous or multiple prominent nucleoli. Cytoplasm was located at the nuclear poles and was fine, wispy, and delicate. The background was clean with no evidence of necrosis or melanin pigment. Papanicolaou-stained ThinPrep slides were prepared from needle rinses and demonstrated excellent correlation of nuclear and cytoplasmic detail of single spindle cells to that seen on conventional smears with the exception of only slight decrease in nuclear size; however, nuclear and cytoplasmic detail of spindle cells embedded in stroma was markedly attenuated. Confirmatory immunostain for S-100 protein in both cases was performed on ThinPrep slides demonstrating crisp cytoplasmic staining in the spindle cells. Conclusion The cytomorphology of desmoplastic melanoma shows excellent correlation between cytomorphology of single spindle cells on conventional smears and on ThinPrep slides. The major difference noted on ThinPrep slides was attenuated nuclear and cytoplasmic detail of spindle cells embedded in fibrous stoma. PMID:17880690
Locke, Robin L.; Miller, Alison L.; Seifer, Ronald; Heinze, Justin E.
2015-01-01
This study examined contextually-inappropriate (CI) anger in relation to emotion recognition and situation knowledge, negative social experiences, and externalizing behavior among low-income 4-year-olds attending Head Start (n=134). Approximately one-quarter of children (23%) showed anger when presented with positive/neutral slides and videos (valence-incongruent CI anger), whereas 2/5 of children (40%) showed anger when presented with negative slides and videos (valence-congruent CI anger). Valence-incongruent CI anger was associated with lower emotion situation knowledge (for boys only), more self-reported peer rejection and loneliness, and greater negative nominations by teachers and peers. Both valence-incongruent and (for boys only) valence-congruent CI anger were positively associated with externalizing behavior. Overall, valence-incongruent CI anger was more strongly associated with negative child outcomes than valence-congruent CI anger. PMID:26376288
SIMULATING THE 'SLIDING DOORS' EFFECT THROUGH MAGNETIC FLUX EMERGENCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacTaggart, David; Hood, Alan W., E-mail: dm428@st-andrews.ac.u
2010-06-20
Recent Hinode photospheric vector magnetogram observations have shown that the opposite polarities of a long arcade structure move apart and then come together. In addition to this 'sliding doors' effect, orientations of horizontal magnetic fields along the polarity inversion line on the photosphere evolve from a normal-polarity configuration to an inverse one. To explain this behavior, a simple model by Okamoto et al. suggested that it is the result of the emergence of a twisted flux rope. Here, we model this scenario using a three-dimensional megnatohydrodynamic simulation of a twisted flux rope emerging into a pre-existing overlying arcade. We constructmore » magnetograms from the simulation and compare them with the observations. The model produces the two signatures mentioned above. However, the cause of the 'sliding doors' effect differs from the previous model.« less
Stick-slip friction and wear of articular joints
Lee, Dong Woog; Banquy, Xavier; Israelachvili, Jacob N.
2013-01-01
Stick-slip friction was observed in articular cartilage under certain loading and sliding conditions and systematically studied. Using the Surface Forces Apparatus, we show that stick-slip friction can induce permanent morphological changes (a change in the roughness indicative of wear/damage) in cartilage surfaces, even under mild loading and sliding conditions. The different load and speed regimes can be represented by friction maps—separating regimes of smooth and stick-slip sliding; damage generally occurs within the stick-slip regimes. Prolonged exposure of cartilage surfaces to stick-slip sliding resulted in a significant increase of surface roughness, indicative of severe morphological changes of the cartilage superficial zone. To further investigate the factors that are conducive to stick-slip and wear, we selectively digested essential components of cartilage: type II collagen, hyaluronic acid (HA), and glycosaminoglycans (GAGs). Compared with the normal cartilage, HA and GAG digestions modified the stick-slip behavior and increased surface roughness (wear) during sliding, whereas collagen digestion decreased the surface roughness. Importantly, friction forces increased up to 2, 10, and 5 times after HA, GAGs, and collagen digestion, respectively. Also, each digestion altered the friction map in different ways. Our results show that (i) wear is not directly related to the friction coefficient but (ii) more directly related to stick-slip sliding, even when present at small amplitudes, and that (iii) the different molecular components of joints work synergistically to prevent wear. Our results also suggest potential noninvasive diagnostic tools for sensing stick-slip in joints. PMID:23359687
Sun, Junhui; Zhang, Yanning; Lu, Zhibin; Xue, Qunji; Wang, Liping
2017-05-10
Friction on a nanoscale revealed rich load-dependent behavior, which departs strongly from the long-standing Amonton's law. Whilst electrostatic repulsion-induced friction collapse for rare gas sliding over metallic surfaces in a high-load regime was reported by Righi et al. (Phys. Rev. Lett., 2007, 99, 176101), the significant role of attraction on frictional properties has not been reported to date. In this study, the frictional motion of Xe/Cu(111), Xe/Pd(111) and Ar/Cu(111) was studied using van der Waals corrected density functional calculations. An attraction-induced zero friction, which is a signal of superlubricity, was found for the sliding systems. The superlubric state results from the disappearance of the potential corrugation along the favored sliding path as a consequence of the potential crossing in the attractive regime when the interfacial pressure approaches a critical-value. The finding of an attraction-driven friction drop, together with the repulsion-induced collapse in the high-load regime, which breaks down the classic Amonton's law, provides a distinct approach for the realization of inherent superlubricity in some adsorbate/substrate interfaces.
Atomic-scale friction modulated by potential corrugation in multi-layered graphene materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhuang, Chunqiang, E-mail: chunqiang.zhuang@bjut.edu.cn; Liu, Lei
2015-03-21
Friction is an important issue that has to be carefully treated for the fabrication of graphene-based nano-scale devices. So far, the friction mechanism of graphene materials on the atomic scale has not yet been clearly presented. Here, first-principles calculations were employed to unveil the friction behaviors and their atomic-scale mechanism. We found that potential corrugations on sliding surfaces dominate the friction force and the friction anisotropy of graphene materials. Higher friction forces correspond to larger corrugations of potential energy, which are tuned by the number of graphene layers. The friction anisotropy is determined by the regular distributions of potential energy.more » The sliding along a fold-line path (hollow-atop-hollow) has a relatively small potential energy barrier. Thus, the linear sliding observed in macroscopic friction experiments may probably be attributed to the fold-line sliding mode on the atomic scale. These findings can also be extended to other layer-structure materials, such as molybdenum disulfide (MoS{sub 2}) and graphene-like BN sheets.« less
Yu, Hong; Gao, Feng; Jiang, Liren; Ma, Shuoxin
2017-09-15
The aim was to develop scalable Whole Slide Imaging (sWSI), a WSI system based on mainstream smartphones coupled with regular optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry objective lenses of different magnifications, and reasonably high throughput. These performance metrics should be evaluated by expert pathologists and match those of high-end scanners. The aim was to develop scalable Whole Slide Imaging (sWSI), a whole slide imaging system based on smartphones coupled with optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry object lens of different magnification. All performance metrics should be evaluated by expert pathologists and match those of high-end scanners. In the sWSI design, the digitization process is split asynchronously between light-weight clients on smartphones and powerful cloud servers. The client apps automatically capture FoVs at up to 12-megapixel resolution and process them in real-time to track the operation of users, then give instant feedback of guidance. The servers first restitch each pair of FoVs, then automatically correct the unknown nonlinear distortion introduced by the lens of the smartphone on the fly, based on pair-wise stitching, before finally combining all FoVs into one gigapixel VS for each scan. These VSs can be viewed using Internet browsers anywhere. In the evaluation experiment, 100 frozen section slides from patients randomly selected among in-patients of the participating hospital were scanned by both a high-end Leica scanner and sWSI. All VSs were examined by senior pathologists whose diagnoses were compared against those made using optical microscopy as ground truth to evaluate the image quality. The sWSI system is developed for both Android and iPhone smartphones and is currently being offered to the public. The image quality is reliable and throughput is approximately 1 FoV per second, yielding a 15-by-15 mm slide under 20X object lens in approximately 30-35 minutes, with little training required for the operator. The expected cost for setup is approximately US $100 and scanning each slide costs between US $1 and $10, making sWSI highly cost-effective for infrequent or low-throughput usage. In the clinical evaluation of sample-wise diagnostic reliability, average accuracy scores achieved by sWSI-scan-based diagnoses were as follows: 0.78 for breast, 0.88 for uterine corpus, 0.68 for thyroid, and 0.50 for lung samples. The respective low-sensitivity rates were 0.05, 0.05, 0.13, and 0.25 while the respective low-specificity rates were 0.18, 0.08, 0.20, and 0.25. The participating pathologists agreed that the overall quality of sWSI was generally on par with that produced by high-end scanners, and did not affect diagnosis in most cases. Pathologists confirmed that sWSI is reliable enough for standard diagnoses of most tissue categories, while it can be used for quick screening of difficult cases. As an ultra-low-cost alternative to whole slide scanners, diagnosis-ready VS quality and robustness for commercial usage is achieved in the sWSI solution. Operated on main-stream smartphones installed on normal optical microscopes, sWSI readily offers affordable and reliable WSI to resource-limited or infrequent clinical users. ©Hong Yu, Feng Gao, Liren Jiang, Shuoxin Ma. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.09.2017.
NASA Astrophysics Data System (ADS)
Weng, C. H.; Lin, M. L.; Hsieh, P. C.
2016-12-01
In recent years, landslides have attracted much attention in the engineering field in Taiwan. As previous studies, landslides are induced by earthquakes, rainfall, and groundwater. That groundwater flows into upper layer through vertical joints, upward groundwater, erodes the slope and reduces its stability. Nevertheless, in the literature, the impact of upward groundwater to the location of sliding surface and the behaviors of dip slope failure has not be investigated. In this study, physical model tests with water flow inclinometers are used to investigate the kinematics of dip slope failures under various conditions and to identify the failure modes of specimens (Fig. 1). Besides, the mechanics of one landslide case owing to upward groundwater is studied by numerical simulation. In the physical tests, the effects of upward groundwater on slope stability are investigated with different angles of inclinometers, different position of joints on specimens and different locations of upward seepage. The test results suggest that the upward water pressure becomes lower when the number of joints increases. As the water pressure increases to 3.8 times the weight of one block of the specimen, the block will slide. Another, when the specimen is covered by one granular content layer (see Fig. 2), the failure surface tends to develop at the granular content layer, and its kinematics is similar to debris slide; when the clay seam is below of the specimen, the translational slide occurs along the bottom of the blocks. Moreover, one dip slope case, Taiwan's National Highway No. 3 landslide event, are studied by numerical simulation. According to the results, some points are concluded: water pressure makes tension cracks on the top of the vertical joints on weathered sandstones; with anchor attenuation, the sandstone moves downslope, which makes the shear strain of the slope toe region increases (see Fig. 3). If friction angle of the slope decreases, the slide surface occurs along the weak surface, and it develops to the toe of the slope.
Ambros, S; Hofer, F; Kulozik, U
2018-05-31
Microwave freeze drying in comparison to conventional freeze drying allows for intensification of the preservation process of lactic acid bacteria without imposing additional processing stress. Viability as a function of storage time of microwave freeze-dried Lactobacillus paracasei ssp. paracasei F19 was investigated in comparison to conventionally lyophilized bacteria of the same strain. Further, the impact of the protectants, sorbitol, trehalose and maltodextrin, on shelf life was analyzed. The highest inactivation rates of 0.035 and 0.045 d -1 , respectively, were found for cultures without protectants. Thus, all additives were found to exhibit a protective effect during storage with inactivation rates between 0.015 and 0.040 d -1 . Although trehalose and maltodextrin samples were in the glassy state during storage, in contrast to samples containing sorbitol as protectant, the best protective effect could be found for sorbitol with the lowest inactivation rate of 0.015 d -1 . Due to its low molecular weight, it might protect cells owing to better adsorption to the cytoplasma membrane. Sorbitol additionally shows antioxidative properties. Storage behavior of microwave freeze-dried cultures follows the typical behavior of a product dried by conventional lyophilization. No significant influence of the drying technique on storage behavior was detected. General findings concerning storage behavior in freeze drying are likely to be applicable in microwave freeze drying with only slight adjustments. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Effects of Load and Speed on Wear Rate of Abrasive Wear for 2014 Al Alloy
NASA Astrophysics Data System (ADS)
Odabas, D.
2018-01-01
In this paper, the effects of the normal load and sliding speed on wear rate of two-body abrasive wear for 2014 Al Alloy were investigated in detail. In order to understand the variation in wear behaviour with load and speed, wear tests were carried out at a sliding distance of 11 m, a speed of 0.36 m/s, a duration of 30 s and loads in the range 3-11 N using 220 grit abrasive paper, and at a speed range 0.09-0.90 m/s, a load of 5 N and an average sliding distance of 11 m using abrasive papers of 150 grit size under dry friction conditions. Before the wear tests, solution treatment of the 2014 Al alloy was carried out at temperatures of 505 and 520 °C for 1 h in a muffle furnace and then quenched in cold water at 15 °C. Later, the ageing treatment was carried out at 185 °C for 8 h in the furnace. Generally, wear rate due to time increased linearly and linear wear resistance decreased with increasing loads. However, the wear rate was directly proportional to the load up to a critical load of 7 N. After this load, the slope of the curves decreased because the excessive deformation of the worn surface and the instability of the abrasive grains began to increase. When the load on an abrasive grain reaches a critical value, the groove width is about 0.17 of the abrasive grain diameter, and the abrasive grains begin to fail. The wear rate due to time increased slightly as the sliding speed increased in the range 0.09-0.90 m/s. The reason for this is that changes arising from strain rate and friction heating are expected with increasing sliding speeds.
Thorstenson, Glenys A; Kusy, Robert P
2002-09-01
When paired with a particular self-ligating bracket design, the material and the geometric characteristics of an archwire influence its resistance to sliding. Four designs of self-ligating brackets (1 with a slide, 3 with clips) were coupled with 5 types of archwires: 14-mil round austenitic nickel-titanium, 16 x 22-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular austenitic nickel-titanium, 19 x 25-mil rectangular martensitic nickel-titanium, and 19 x 25-mil rectangular stainless steel. The resistance to sliding (RS) of each archwire-bracket couple was measured at second-order angles between -9 degrees and 9 degrees. Interbracket distances of 8 and 18 mm between the test bracket and the adjacent brackets mimicked closure of a premolar extraction. When clearance exists, the RS is negligible for self-ligating brackets with slides coupled to any size of wire as well as for those with clips when coupled to wires that do not contact the clip. Once the wire attains a certain size and contacts the clip, the RS depends on the archwire size, the bracket design, and the materials of the couple. When coupled with the 16 x 22-mil wire, the brackets with clips applied normal forces ranging from a low of 5.6 centi-Newtons (cN) (1 cN = 1 g) to a high of 230 cN. When clearance disappears, the RS increased proportionally with the second-order angle. The 19 x 25-mil stainless steel wires, which were the most stiff, increased at rates between 75 and 84 cN/degree; the 14-mil austenitic nickel-titanium wires, which were the least stiff, increased at rates from 2.6 to 5.4 cN/degree. The treatment objectives for a particular patient at a specific stage should determine the appropriate archwire-bracket combination.
NASA Astrophysics Data System (ADS)
Falsaperla, S.; Maiolino, V.; Spampinato, S.; Jaquet, O.; Neri, M.
2008-04-01
Repeated phenomena of flank instability accompanied the 28 December 2002 to 21 July 2003 eruption of Stromboli volcano. The major episodes were two tsunamigenic landslides on 30 December 2002, 2 d after the volcano unrest. After 30 December, sliding processes remodeled the area affected by slope instability. We propose analyses of 565 sliding episodes taking place from December 2002 to February 2003. We try to shed light on their main seismic features and links with the ongoing seismic and volcanic activity using variogram analysis as well. A characterization of the seismic signals in the time and frequency domains is presented for 185 sliding episodes. Their frequency content is between 1 Hz and 7 Hz. On the basis of the dominant peaks and shape of the spectrum, we identify three subclasses of signals, one of which has significant energy below 2 Hz. Low-frequency signatures were also found in the seismic records of the landslides of 30 December, which affected the aerial and submarine northwestern flank of the volcano. Accordingly, we surmise that spectral analysis might provide evidence of sliding phenomena with submarine runouts. We find no evidence of sliding processes induced by earthquakes. Additionally, a negative statistical correlation between sliding episodes and explosion quakes is highlighted by variogram analysis. Variograms indicate a persistent behavior, memory, of the flank instability from 5 to 10 d. We interpret the climax in the occurrence rate of the sliding processes between 24 and 29 January 2003 as the result of favorable conditions to slope instability due to the emplacement of NW-SE aligned, dike-fed vents located near the scarp of the landslide area. Afterward, the stabilizing effect of the lava flows over the northwestern flank of the volcano limited erosive phenomena to the unstable, loose slope not covered by lava.
Physicochemical Processes and the Evolution of Strength in Calcite Fault Gouge at Room Temperature
NASA Astrophysics Data System (ADS)
Carpenter, B. M.; Viti, C.; Collettini, C.
2015-12-01
The presence of calcite in and near faults, as the dominant material, cement, or vein fill, indicates that the mechanical behavior of carbonate-dominated material likely plays an important role in shallow- and mid-crustal faulting. Furthermore, a variety of physical and chemical processes control the evolution of strength and style of slip along seismogenic faults and thus play a critical role in the seismic cycle. Determining the role and contributions of these types of mechanisms is essential to furthering our understanding of the processes and timescales that lead to the strengthening of faults during interseismic periods and their behavior during the earthquake nucleation process. To further our understanding of these processes, we performed laboratory-shearing experiments on calcite gouge at normal stresses from 1 to 100 MPa, under conditions of saturation and at room temperature. We performed velocity stepping (0.1-1000μm/s) and slide-hold-slide (1-3000s) tests, to measure the velocity dependence of friction and the amount of frictional strengthening respectively, under saturated conditions with pore fluid that was in equilibrium with CaCO3. At 5 MPa normal stress, we also varied the environmental conditions by performing experiments under conditions of 5% RH and 50 % RH, and saturation with: silicone oil, demineralized water, and the equilibrated solution combined with 0.5M NaCl. Finally, we collected post experimental samples for microscopic analysis. Our combined analyses of rate-dependence, strengthening behavior, and microstructures show that calcite fault gouge transitions from brittle to semi-brittle behavior at high normal stress and low sliding velocities. Furthermore, our results also highlight how changes in pore water chemistry can have significant influence on the mechanical behavior of calcite gouge in both the laboratory and in natural faults. Our observations have important implications for earthquake nucleation and propagation on faults in carbonate-dominated lithologies.
Spirochaetemia in a HIV positive patient.
Okwori, E E
2006-01-01
Borreliosis, caused by Borrelia recurrentis and several other Borrelia species is not a commonly reported case in our environment, but the search for the cause of recurrent pyrexia in this patient made it possible to discover the spirochete as the cause of the disease. A 38 year old married HIV positive woman presented with recurrent fever in a private clinic. Six thin smears were made out of the patient serum and dried in the air. Three slides each were stained with 0.12% Leishman and 20% Giemsa stains and examined under the light microscope. Three of the Giemsa slides were positive for spirochetes (4-5 spirals), which were constituents with Borrelia species. The patient responded very well to tetracycline and serum became negative for the organism after ten days of treatment. Borrelia was discovered to be the cause of the recurrent pyrexia in this patient who responded very well to tetracycline. Borrelia should be looked for in cases of pyrexia of unknown origin
NASA Astrophysics Data System (ADS)
Lei, Yu; Du, Jinfang; Pang, Xianjuan; Wang, Haizhong; Yang, Hua; Jiang, Jinlong
2018-05-01
A solid-liquid synergetic lubricating system has been designed to develop a novel self-lubricating nickel matrix composite. The graphene-nickel (G-Ni) matrix composite with porous structure was fabricated by in situ growing graphene in bulk nickel using a powder metallurgy method. The porous structures of the composite were used to store polyalphaolefin (PAO) oil for self-lubricating. It is found that the G-Ni matrix composite under oil lubrication condition exhibited superior tribological properties as compared to pure nickel and the composite under dry sliding condition. The prestored oil was released from pores to the sliding surface forming a lubricating oil film during friction process. This lubricating oil film can protect the worn surface from severe oxidation, and help the formation and transfer of a carbon-based solid tribofilm derived from graphene and lubricating oil. This solid (graphene)-liquid (oil) synergistic lubricating mechanism is responsible for the reduction of friction coefficient and improvement of wear resistance of the in situ fabricated G-Ni matrix composite.
NASA Astrophysics Data System (ADS)
Burkov, Alexander A.; Pyachin, S. A.; Ermakov, M. A.; Syuy, A. V.
2017-02-01
Crystalline FeWMoCrBC electrode materials were prepared by conventional powder metallurgy. Metallic glass (MG) coatings were produced by electrospark deposition onto AISI 1035 steel in argon atmosphere. X-ray diffraction and scanning electron microscopy verified the amorphous structure of the as-deposited coatings. The coatings have a thickness of about 40 microns and a uniform structure. The results of dry sliding wear tests against high-speed steel demonstrated that Fe-based MG coatings had a lower friction coefficient and more than twice the wear resistance for 20 km sliding distance with respect to AISI 1035 steel. High-temperature oxidation treatment of the metal glass coatings at 1073 K in air for 12 h revealed that the oxidation resistance of the best coating was 36 times higher than that for bare AISI 1035 steel. These findings are expected to broaden the applications of electrospark Fe-based MG as highly protective and anticorrosive coatings for mild steel.
DEM modeling of flexible structures against granular material avalanches
NASA Astrophysics Data System (ADS)
Lambert, Stéphane; Albaba, Adel; Nicot, François; Chareyre, Bruno
2016-04-01
This article presents the numerical modeling of flexible structures intended to contain avalanches of granular and coarse material (e.g. rock slide, a debris slide). The numerical model is based on a discrete element method (YADE-Dem). The DEM modeling of both the flowing granular material and the flexible structure are detailed before presenting some results. The flowing material consists of a dry polydisperse granular material accounting for the non-sphericity of real materials. The flexible structure consists in a metallic net hanged on main cables, connected to the ground via anchors, on both sides of the channel, including dissipators. All these components were modeled as flexible beams or wires, with mechanical parameters defined from literature data. The simulation results are presented with the aim of investigating the variability of the structure response depending on different parameters related to the structure (inclination of the fence, with/without brakes, mesh size opening), but also to the channel (inclination). Results are then compared with existing recommendations in similar fields.
Laser Surface Treatment and Modification of Aluminum Alloy Matrix Composites
NASA Astrophysics Data System (ADS)
Abbass, Muna Khethier
2018-02-01
The present work aimed to study the laser surface treatment and modification of Al-4.0%Cu-1.0%Mg alloy matrix composite reinforced with 10%SiC particles produced by stir casting. The specimens of the base alloy and composite were irradiated with an Nd:YAG laser of 1000 mJ, 1064 nm and 3 Hz . Dry wear test using the pin-on -disc technique at different sliding times (5-30 min) at a constant applied load and sliding speed were performed before and after laser treatment. Micro hardness and wear resistance were increased for all samples after laser hardening treatment. The improvement of these properties is explained by microstructural homogenization and grain refinement of the laser treated surface. Modification and refinement of SiC particles and grain refinement in the microstructure of the aluminum alloy matrix (α-Al) were observed by optical and SEM micrographs. The highest increase in hardness was 21.4% and 26.2% for the base alloy and composite sample respectively.
Friction is Fracture: a new paradigm for the onset of frictional motion
NASA Astrophysics Data System (ADS)
Fineberg, Jay
Friction is generally described by a single degree of freedom, a `friction coefficient'. We experimentally study the space-time dynamics of the onset of dry and lubricated frictional motion when two contacting bodies start to slide. We first show that the transition from static to dynamic sliding is governed by rupture fronts (closely analogous to earthquakes) that break the contacts along the interface separating the two bodies. Moreover, the structure of these ''laboratory earthquakes'' is quantitatively described by singular solutions originally derived to describe the motion of rapid cracks under applied shear. We demonstrate that this framework quantitatively describes both earthquake motion and arrest. This framework also providing a new window into the hidden properties of the micron thick interface that governs a body's frictional properties. Using this window we show that lubricated interfaces, although ``slippery'', actually becomes tougher; lubricants significantly increase dissipated energy during rupture. The results establish a new (and fruitful) paradigm for describing friction. Israel Science Foundation, ERC.
Tactile Perception of Roughness and Hardness to Discriminate Materials by Friction-Induced Vibration
Zhao, Xuezeng
2017-01-01
The human fingertip is an exquisitely powerful bio-tactile sensor in perceiving different materials based on various highly-sensitive mechanoreceptors distributed all over the skin. The tactile perception of surface roughness and material hardness can be estimated by skin vibrations generated during a fingertip stroking of a surface instead of being maintained in a static position. Moreover, reciprocating sliding with increasing velocities and pressures are two common behaviors in humans to discriminate different materials, but the question remains as to what the correlation of the sliding velocity and normal load on the tactile perceptions of surface roughness and hardness is for material discrimination. In order to investigate this correlation, a finger-inspired crossed-I beam structure tactile tester has been designed to mimic the anthropic tactile discrimination behaviors. A novel method of characterizing the fast Fourier transform integral (FFT) slope of the vibration acceleration signal generated from fingertip rubbing on surfaces at increasing sliding velocity and normal load, respectively, are defined as kv and kw, and is proposed to discriminate the surface roughness and hardness of different materials. Over eight types of materials were tested, and they proved the capability and advantages of this high tactile-discriminating method. Our study may find applications in investigating humanoid robot perceptual abilities. PMID:29182538
Damping behavior of nano-fibrous composites with viscous interface in anti-plane shear
NASA Astrophysics Data System (ADS)
Wang, Xu
2017-06-01
By using the composite cylinder assemblage model, we derive an explicit expression of the specific damping capacity of nano-fibrous composite with viscous interface when subjected to time-harmonic anti-plane shear loads. The fiber and the matrix are first endowed with separate and distinct Gurtin-Murdoch surface elasticities, and rate-dependent sliding occurs on the fiber-matrix interface. Our analysis indicates that the effective damping of the composite depends on five dimensionless parameters: the fiber volume fraction, the stiffness ratio, two parameters arising from surface elasticity and one parameter due to interface sliding.
Listening in on Friction: Stick-Slip Acoustical Signatures in Velcro
NASA Astrophysics Data System (ADS)
Hurtado Parra, Sebastian; Morrow, Leslie; Radziwanowski, Miles; Angiolillo, Paul
2013-03-01
The onset of kinetic friction and the possible resulting stick-slip motion remain mysterious phenomena. Moreover, stick-slip dynamics are typically accompanied by acoustic bursts that occur temporally with the slip event. The dry sliding dynamics of the hook-and-loop system, as exemplified by Velcro, manifest stick-slip behavior along with audible bursts that are easily micrphonically collected. Synchronized measurements of the friction force and acoustic emissions were collected as hooked Velcro was driven at constant velocity over a bed of looped Velcro in an anechoic chamber. Not surprising, the envelope of the acoustic bursts maps well onto the slip events of the friction force time series and the intensity of the bursts trends with the magnitude of the difference of the friction force during a stick-slip event. However, the analysis of the acoustic emission can serve as a sensitive tool for revealing some of the hidden details of the evolution of the transition from static to kinetic friction. For instance, small acoustic bursts are seen prior to the Amontons-Coulomb threshold, signaling precursor events prior to the onset of macroscopically observed motion. Preliminary spectral analysis of the acoustic emissions including intensity-frequency data will be presented.
The inverse hall-petch relation in nanocrystalline metals: A discrete dislocation dynamics analysis
NASA Astrophysics Data System (ADS)
Quek, Siu Sin; Chooi, Zheng Hoe; Wu, Zhaoxuan; Zhang, Yong Wei; Srolovitz, David J.
2016-03-01
When the grain size in polycrystalline materials is reduced to the nanometer length scale (nanocrystallinity), observations from experiments and atomistic simulations suggest that the yield strength decreases (softening) as the grain size is decreased. This is in contrast to the Hall-Petch relation observed in larger sized grains. We incorporated grain boundary (GB) sliding and dislocation emission from GB junctions into the classical DDD framework, and recovered the smaller is weaker relationship observed in nanocrystalline materials. This current model shows that the inverse Hall-Petch behavior can be obtained through a relief of stress buildup at GB junctions from GB sliding by emitting dislocations from the junctions. The yield stress is shown to vary with grain size, d, by a d 1 / 2 relationship when grain sizes are very small. However, pure GB sliding alone without further plastic accomodation by dislocation emission is grain size independent.
Abrasive wear behavior of in-situ RZ5-10wt%TiC composite
NASA Astrophysics Data System (ADS)
Mehra, Deepak; Mahapatra, M. M.; Harsha, S. P.
2018-05-01
RZ5 Magnesium alloys containing zinc, rare earth and zirconium are well-known to have high specific strength, good creep resistance widely used in aerospace components. The incorporation of hard ceramic strengthens RZ5 mg alloy. The RZ5-10wt%TiC composite has been fabricated in situ using RZ5 mg alloy as matrix and TiC as reinforcement by self propagating high temperature synthesis (SHS) technique. This paper investigates the abrasive wear behavior of RZ5-10wt%TiC. Tests were performed using pin-on-disc apparatus against 600 grit abrasive paper by varying the sliding distance and applied load. The results showed improvement in the wear resistance of testing composite as compared to the unreinforced RZ5 Mg alloy. The coefficient of friction and weight loss increased linearly as applied load and sliding distance increased. The field emission scanning electron microscopic (FESEM) showed dominate wear mechanisms: abrasion, ploughing grooves.
NASA Technical Reports Server (NTRS)
Ho, T. L.; Peterson, M. B.
1974-01-01
The requirements of brake materials were outlined and a survey made to select materials to meet the needs of high temperature brakes. A number of metals and ceramic materials were selected and evaluated in sliding tests which simulated aircraft braking. Nickel, molybdenum tungsten, Zr02, high temperature cements and carbons were tested. Additives were then incorporated into these materials to optimize their wear or strength behavior with particular emphasis on nickel and molybdenum base materials and a high temperature potassium silicate cement. Optimum materials were developed which improved wear behavior over conventional brake materials in the simulated test. The best materials are a nickel, aluminum oxide, lead tungstate composition containing graphite or molybdenum disulphite; a molybdenum base material containing LPA100 (an intermetallic compound of cobalt, molybdenum, and silicon); and a carbon material (P5).
Damage tolerant functionally graded materials for advanced wear and friction applications
NASA Astrophysics Data System (ADS)
Prchlik, Lubos
The research work presented in this dissertation focused on processing effects, microstructure development, characterization and performance evaluation of composite and graded coatings used for friction and wear control. The following issues were addressed. (1) Definition of prerequisites for a successful composite and graded coating formation by means of thermal spraying. (2) Improvement of characterization methods available for homogenous thermally sprayed coating and their extension to composite and graded materials. (3) Development of novel characterization methods specifically for FGMs, with a focus on through thickness property measurement by indentation and in-situ curvature techniques. (4) Design of composite materials with improved properties compared to homogenous coatings. (5) Fabrication and performance assessment of FGM with improved wear and impact damage properties. Materials. The materials studied included several material systems relevant to low friction and contact damage tolerant applications: MO-Mo2C, WC-Co cermets as materials commonly used sliding components of industrial machinery and NiCrAlY/8%-Yttria Partially Stabilized Zirconia composites as a potential solution for abradable sections of gas turbines and aircraft engines. In addition, uniform coatings such as molybdenum and Ni5%Al alloy were evaluated as model system to assess the influence of microstructure variation onto the mechanical property and wear response. Methods. The contact response of the materials was investigated through several techniques. These included methods evaluating the relevant intrinsic coating properties such as elastic modulus, residual stress, fracture toughness, scratch resistance and tests measuring the abrasion and friction-sliding behavior. Dry-sand and wet two-body abrasion testing was performed in addition to traditional ball on disc sliding tests. Among all characterization techniques the spherical indentation deserved most attention and enabled to measure elastic-plastic properties of uniform and graded structures. In-situ curvature method used for residual stress and elastic modulus measurement was extended from uniform coatings to coatings with compositional/property gradients. Properties of composite and graded materials were measured using the inverse analysis. Conclusions. The specifics of the elastic-plastic response for thermally sprayed coatings were demonstrated. These included the strain dependence of elastic modulus and damage accumulation related to unloading/reloading loop formation. The measurement of elastic-plastic characteristics of composite coatings revealed the mixing and bonding mechanisms unique for thermally sprayed materials. Microstructural and compositional factors governing the frictional vs. abrasion response of carbide-metallic composite coatings were described. The measurement of abrasion resistance and friction sliding properties demonstrated that grading of cermet and ceramic coatings by adding moderate amount of metallic alloys can enhance elastic-properties radically and have a beneficial effect onto the coating performance.
Synthesis and statistical modelling of dry sliding wear of Al 8011/6 vol.% AlB2 in situ composite
NASA Astrophysics Data System (ADS)
Kumar, Narendra; Singh, Sandeep Kumar; Gautam, Gaurav; Padap, Aditya Kumar; Mohan, Anita; Mohan, Sunil
2017-10-01
The present study has used response surface methodology (RSM) and central composite design (CCD) for modelling, using wear parameters to predict the wear performance of an Al 8011/6.0 vol.% AlB2 composite. The effect of applied load and sliding velocity was studied at five levels for a fixed sliding distance. To understand wear behaviour, sliding wear tests were planned according to CCD and performed on a pin-on-disc apparatus at ambient temperature. An analysis of variance (ANOVA) was conducted to show the relative significance of the parameters. A second-order regression model was developed to predict the wear loss and to establish the relationships between wear parameters. Response surface and contour plots were drawn to analyse the wear results. Worn surfaces were examined under scanning electron microscope (SEM), and energy dispersive spectroscopy (EDS) was used to interpret the operative wear mechanisms. Validation tests results show good agreement between experimental and predicted data. As an initial step of this study, AlB2 particles were reinforced in Al 8011 alloy by an in situ technique to synthesise an Al 8011/6.0 vol.% AlB2 composite. During synthesis an in situ reaction takes place between molten alloy and inorganic salt KBF4 at 850 °C, which leads to the formation of AlB2 particles. The composite was analysed by x-ray diffractometer (XRD) to detect the phases present, while optical and scanning electron microscopy (OM & SEM) were carried out to ascertain morphology and particle distribution. Hardness was evaluated by a Vickers hardness testing machine.
NASA Astrophysics Data System (ADS)
Buijze, Loes; Niemeijer, André R.; Han, Raehee; Shimamoto, Toshihiko; Spiers, Christopher J.
2017-01-01
The evolution of friction as a function of slip rate is important in understanding earthquake nucleation and propagation. Many laboratory experiments investigating friction of fault rocks are either conducted in the low velocity regime (10-8-10-4 ms-1) or in the high velocity regime (0.01-1 m s-1). Here, we report on the evolution of friction and corresponding operating deformation mechanisms in analog gouges deformed from low to high slip rates, bridging the gap between these low and high velocity regimes. We used halite and halite-muscovite gouges to simulate processes, governing friction, active in upper crustal quartzitic fault rocks, at conditions accessible in the laboratory. The gouges were deformed over a 7 orders of magnitude range of slip rate (10-7-1 m s-1) using a low-to-high velocity rotary shear apparatus, using a normal stress of 5 MPa and room-dry humidity. Microstructural analysis was conducted to study the deformation mechanisms. Four frictional regimes as a function of slip rate could be recognized from the mechanical data, showing a transitional regime and stable sliding (10-7-10-6 m s-1), unstable sliding and weakening (10-6-10-3 m s-1), hardening (10-2-10-1 m s-1) and strong weakening (10-1-1 m s-1). Each of the four regimes can be associated with a distinct microstructure, reflecting a transition from mainly brittle deformation accompanied by pressure solution healing to temperature activated deformation mechanisms. Additionally, the frictional response of a sliding gouge to a sudden acceleration of slip rate to seismic velocities was investigated. These showed an initial strengthening, the amount of which depended on the friction level at which the step was made, followed by strong slip weakening.
Chen, Lei; He, Hongtu; Wang, Xiaodong; Kim, Seong H; Qian, Linmao
2015-01-13
Wear at sliding interfaces of silicon is a main cause for material loss in nanomanufacturing and device failure in microelectromechanical system (MEMS) applications. However, a comprehensive understanding of the nanoscale wear mechanisms of silicon in ambient conditions is still lacking. Here, we report the chemical wear of single crystalline silicon, a material used for micro/nanoscale devices, in humid air under the contact pressure lower than the material hardness. A transmission electron microscopy (TEM) analysis of the wear track confirmed that the wear of silicon in humid conditions originates from surface reactions without significant subsurface damages such as plastic deformation or fracture. When rubbed with a SiO2 ball, the single crystalline silicon surface exhibited transitions from severe wear in intermediate humidity to nearly wearless states at two opposite extremes: (a) low humidity and high sliding speed conditions and (b) high humidity and low speed conditions. These transitions suggested that at the sliding interfaces of Si/SiO2 at least two different tribochemical reactions play important roles. One would be the formation of a strong "hydrogen bonding bridge" between hydroxyl groups of two sliding interfaces and the other the removal of hydroxyl groups from the SiO2 surface. The experimental data indicated that the dominance of each reaction varies with the ambient humidity and sliding speed.
Dry friction aspects of Ni-based self-fluxing flame sprayed coatings
NASA Astrophysics Data System (ADS)
Paulin, C.; Chicet, D.; Paleu, V.; Benchea, M.; Lupescu, Ş.; Munteanu, C.
2017-08-01
In this paper we present the results tribological obtained in the course of dry wear tests on samples coated with three types of coatings produced from self-fluxing Ni-based powders. In this purpose were used three commercial NiCrBSi powders produced by various manufacturers, which have been sprayed against a low alloyed steel substrate using the flame spray thermal deposition method followed by flame remelting, resulting three different samples, denoted as: A, M and P. The first test was conducted on an Amsler type machine, with rolling motion between tribological contacts of third class. The analysed coating was deposited on the generator of the low alloy steel disc and the shoe was realized from a grindstone. The test was conducted for two situations: (a) constant load of 10 kg and 6 kg applied for 5 hours; (b) progressive load starting from 2 to 10 kg for two different speeds of rotation of the disc. The second test was the one of sliding wear and it was conducted on the UMTR 2M-CTR tribometer. The analysed layers were deposited on the flat surface of a low alloy steel lamella, and the friction was achieved with a conical grinding stone. The working parameters were as follows: 20N constant load, constant speed of 10 mm / s, sliding linear length of 30mm, the test duration being 45 minutes. After conducting the tests and after analysing the results, the following conclusions are drawn: a) during the first test has been obtained a global friction coefficient between 0.3 and 0.4 - typical for dry friction, highlighting some lower values in the case of sample A, in which case there were recorded smaller mass losses; b) at the second test was recorded an approximately linear behaviour of the three samples, with a gradual increase of the friction coefficient and a superficial wear mark revealed both by SEM microscopy and by profilometry.
Wetting behavior and drainage of water droplets on microgrooved brass surfaces.
Rahman, M Ashiqur; Jacobi, Anthony M
2012-09-18
In the present study, contact angle hysteresis and sliding behavior of water droplets on parallel, periodic microgrooved brass surfaces are investigated experimentally for enhancement of water drainage and compared to that on flat baseline surfaces. The surfaces (a total of 17 microgrooved samples, with a range of groove depth of 22 to 109 μm, pillar width of 26 to 190 μm, and groove width of 103 and 127 μm) are fabricated using a mechanical micromachining process. The wetting state and shape/elongation of deposited water droplets, anisotropy of the contact angle hysteresis, and the drainage behavior of water droplets on the microgrooved surfaces are found to be strongly dependent on the topography of the groove geometry, which is analyzed in detail. The wetting state is found to be Wenzel for microgrooved surfaces with very low aspect ratio (<0.2) and narrow pillars (pillar width to groove width ratio of ≈0.2), and also for the two deepest grooved surfaces of two different sample series, all of which exhibit high contact angle hysteresis. Mechanisms of the advancing and receding motions are identified. The critical sliding angle (the angle from horizontal at incipient motion of the advancing confluence) for the microgrooved surfaces is found to be significantly smaller than for flat surfaces. The sliding angle exhibits significant groove geometry dependence and is found to increase with pillar width and decrease with groove depth. The findings of this study may be useful in a broad range of applications where water retention plays an important role.
Tribological Behavior and Corrosion Resistance of Electroless Ni-B-W Coatings
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Arkadeb; Barman, Tapan Kumar; Sahoo, Prasanta
The present study considers the tribological behavior and corrosion resistance of electroless Ni-B-W coatings deposited on AISI 1040 steel substrates. Coating is characterized using scanning electron microscopy, energy dispersive X-ray analysis and X-ray diffraction technique. In as-deposited condition, coatings are found to be amorphous. On heat treatment, precipitation of crystalline Ni (1 1 1) and its borides take place. For as-deposited coating, the microhardness is obtained as ˜759HV100 which increases to ˜1181HV100 and ˜1098HV100 when heat treated at 350∘C and 450∘C, respectively. Incorporation of W in Ni-B coating results in an increase of hardness by 89HV100 in as-deposited condition. Heat treatment also results in increase in crystallite size of Ni (1 1 1). Wear rate and coefficient of friction (COF) of the coatings are evaluated on a pin-on-disc setup under both dry and lubricated sliding conditions. Wear resistance is observed to improve on heat treatment with an increase in crystallite size while COF deteriorates. However, in as-deposited condition, wear rate and COF of Ni-B-W coatings improve by ˜5 and ˜3 times, respectively, compared with Ni-B coatings. Wear and friction performance of the coatings are enhanced under lubrication due to the columnar structure of the coatings that retain lubricants. Corrosion resistance of Ni-B-W coating in 3.5% NaCl solution gets improved on heat treatment.
Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.
Wen, Fuh Liang; Yen, Chi Yung; Ouyang, Minsun
2003-08-01
The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) membrane bonded on a metal sheet. Such a concentric PZT structure possesses the electrical and mechanical coupling characteristics in flexural wave. The driving ability of the actuator comes from the mechanical vibration of extension and shrinkage of a metal sheet due to the converse piezoelectric effect, corresponding to the frequency of a single-phase AC power. By applying the constraints on the specific geometry positions on the metal sheet, the various behaviors of flexural waves have been at the different directions. The rotor is impelled by the actuator with rotational speeds of 600 rpm in maximum using a friction-contact mechanism. Very high actuating and braking abilities are obtained. This simple and inexpensive structure of actuator demonstrates that the mechanical design of actuator and rotor could be done separately and flexibly according to the requirements for various applications. And, its running accuracy and positioning precision are described in Part II.A closed loop servo positioning control i.e. sliding mode control (SMC) is used to compensate automatically for nonlinearly mechanical behaviors such as dry friction, ultrasonic vibrating, slip-stick phenomena. Additionally, SMC scheme has been successfully applied to position tracking to prove the excellent robust performance in noise rejection.
[Investigation of Acaroid mites breeding in stored dry fruits].
Tao, Ning; Zhan, Xiao-dong; Sun, En-tao; Li, Chao-pin
2015-12-01
To study the species and density of Acaroid mites breeding in stored dry fruits. The samples from the dried fruit stores and warehouses were collected, and the mites breeding in them were separated, then the slides with mites were prepared and observed by a light microscope for species identification and counting. The indexes such as the breeding density, species richness index, diversity index and evenness index were calculated. Totally 12 species of Acaroid mites belonging to 6 families and 10 genera were obtained from the total 49 samples. The dominant mite species were Carpoglyphus lactis, Tyrophagus putrescentiae, Acarus siro, and Caloglyphus berlesei. The breeding densities of mites in longans, filberts and plum candies were 79.78, 48.91, 35.73 mites/g, respectively, which were higher than those in other dry fruits. The seasonal variation experiment of mites found that the average breeding density of acaroid mites was higher in July and October, the richness index and diversity index reached the highest value in July, and the evenness index was higher in January and April. The observation of the growth and decline of Acaroid mites under the artificial condition found the number of Caloglyphus berlesei declined sharply and Tyrophagus putrescentiae first increased and then decreased. The pollution of Acaroid mites is serious in the stored dried fruits, for which the positive prevention and control measures to the mite breeding should be taken to reduce the harm.
Ribbons of semithin sections: an advanced method with a new type of diamond knife.
Blumer, Michael J F; Gahleitner, P; Narzt, T; Handl, C; Ruthensteiner, B
2002-10-15
Complete series of semithin sections are imperative for 3-D reconstruction, but with traditional microtomy techniques it is difficult and time-consuming to trace stained and labeled structures. In the present study we introduce a method for making and collecting ribbons of semithin sections with a new, commercial available diamond knife (histo-jumbo-diamond knife, Diatome AG, Biel, Switzerland). The special feature of the diamond knife is the large water bath (boat) into which a glass slide can be dipped. The method has distinct advantages and the handling is simple. The resin block is trimmed into a truncated pyramid. Contact glue is applied to the leading face of the pyramid, which makes sections stick together to form a ribbon. Following sectioning, the ribbons are mounted onto glass slides and aligned in parallel. Stretching out and drying the ribbons on a hot plate is the final step of the method. Major advantages of this method are the perfect alignment of sections with identical orientation of structures, the completeness of series, and the significant saving of time. This facilitates tracing of stained and labeled structures, yielding quick 3-D reconstruction. Semithin sections can be cut from 0.5 to 2 micro m and several ribbons can be mounted side by side onto the slide. Two examples are presented to illustrate the advantages of the method.
Immunophenotyping by slide-based cytometry and by flow cytometry are comparable
NASA Astrophysics Data System (ADS)
Gerstner, Andreas O.; Laffers, Wiebke; Mittag, Anja; Daehnert, Ingo; Lenz, Domnik; Bootz, Friedrich; Bocsi, Jozsef; Tarnok, Attila
2005-03-01
Immunophenotyping of peripheral blood leukocytes (PBLs) is performed by flow cytometry (FCM) as the golden standard. Slide based cytometry systems for example laser scanning cytometer (LSC) can give additional information (repeated staining and scanning, morphology). In order to adequately judge on the clinical usefulness of immunophenotyping by LSC it is obligatory to compare it with the long established FCM assays. We performed this study to systematically compare the two methods, FCM and LSC for immunophenotyping and to test the correlation of the results. Leucocytes were stained with directly labeled monoclonal antibodies with whole blood staining method. Aliquots of the same paraformaldehyde fixed specimens were analyzed in a FACScan (BD-Biosciences) using standard protocols and parallel with LSC (CompuCyte) after placing to glass slide, drying and fixation by aceton and 7-AAD staining. Calculating the percentage distribution of PBLs obtained by LSC and by FCM shows very good correlation with regression coefficients close to 1.0 for the major populations (neutrophils, lymphocytes, and monocytes), as well as for the lymphocyte sub-populations (T-helper-, T-cytotoxic-, B-, NK-cells). LSC can be recommended for immunophenotyping of PBLs especially in cases where only very limited sample volumes are available or where additional analysis of the cells" morphology is important. There are limitations in the detection of rare leucocytes or weak antigens where appropriate amplification steps for immunofluorescence should be engaged.
Behavioral Criteria in Research and the Study of Racism: Performing the Jackal Function (Part II).
ERIC Educational Resources Information Center
Hilliard, Asa G.; Jenkins, Yolanda L.
This document describes the methodology and results of a pilot study and outlines the hypotheses and procedures of a final study to identify and measure racist behaviors and attitudes in adults. The impact of a slide presentation on racial attitudes was also examined. The context of the pilot study was a workshop on race relations designed to…
Maharaj, Dave
2012-01-01
Summary Nano-object additives are used in tribological applications as well as in various applications in liquids requiring controlled manipulation and targeting. On the macroscale, nanoparticles in solids and liquids have been shown to reduce friction and wear. On the nanoscale, atomic force microscopy (AFM) studies have been performed in single- and multiple-nanoparticle contact, in dry environments, to characterize friction forces and wear. However, limited studies in submerged liquid environments have been performed and further studies are needed. In this paper, spherical Au nanoparticles were studied for their effect on friction and wear under dry conditions and submerged in water. In single-nanoparticle contact, individual nanoparticles, deposited on silicon, were manipulated with a sharp tip and the friction force was determined. Multiple-nanoparticle contact sliding experiments were performed on nanoparticle-coated silicon with a glass sphere. Wear tests were performed on the nanoscale with AFM as well as on the macroscale by using a ball-on-flat tribometer to relate friction and wear reduction on the nanoscale and macroscale. Results indicate that the addition of Au nanoparticles reduces friction and wear. PMID:23213639
NASA Astrophysics Data System (ADS)
Huang, Da; Song, Yixiang; Cen, Duofeng; Fu, Guoyang
2016-12-01
Discontinuous deformation analysis (DDA) as an efficient technique has been extensively applied in the dynamic simulation of discontinuous rock mass. In the original DDA (ODDA), the Mohr-Coulomb failure criterion is employed as the judgment principle of failure between contact blocks, and the friction coefficient is assumed to be constant in the whole calculation process. However, it has been confirmed by a host of shear tests that the dynamic friction of rock joints degrades. Therefore, the friction coefficient should be gradually reduced during the numerical simulation of an earthquake-induced rockslide. In this paper, based on the experimental results of cyclic shear tests on limestone joints, exponential regression formulas are fitted for dynamic friction degradation, which is a function of the relative velocity, the amplitude of cyclic shear displacement and the number of its cycles between blocks with an edge-to-edge contact. Then, an improved DDA (IDDA) is developed by implementing the fitting regression formulas and a modified removing technique of joint cohesion, in which the cohesion is removed once the `sliding' or `open' state between blocks appears for the first time, into the ODDA. The IDDA is first validated by comparing with the theoretical solutions of the kinematic behaviors of a sliding block on an inclined plane under dynamic loading. Then, the program is applied to model the Donghekou landslide triggered by the 2008 Wenchuan earthquake in China. The simulation results demonstrate that the dynamic friction degradation of joints has great influences on the runout and velocity of sliding mass. Moreover, the friction coefficient possesses higher impact than the cohesion of joints on the kinematic behaviors of the sliding mass.
2015-08-10
stainless steel foil substrates that were 50 microns thick. The coatings were then placed in an oven at 60oC for 24 hours to evaporate the solvent. After...drying, the coatings were cooled at room temperature in a fume hood for 24 hours. The free standing film is photographed in Figure 2. The film was cut...composition were examined and flame speeds were measured. A glass slide with the sample strip attached was placed on a steel block housed in a
NASA Astrophysics Data System (ADS)
Hu, Hong-J.; Sun, Z.; Ou, Z.-W.
2016-12-01
Extrusion-shear (ES) process for magnesium alloy is a newly developed plastic deformation process, and ES process combines direct extrusion and two steps of ECAE (equal channel angular extrusion). To investigate the effects of the die channel angles on the microstructures and wear behaviors of AZ61 wrought magnesium alloy, the samples used in this study were fabricated by ES process with different die channel angles (120° and 135°). The microstructures of the samples were characterized by optical microscopy (OM), X-ray diffraction (XRD) and (SEM). The cumulative strains in the ES process were predicted by approaches of numerical simulation and theoretical calculation. To characterize the wear resistance of the samples, pin-on-disk tests under dry sliding conditions with various normal loads and reciprocating frequencies were conducted. To define the wear mechanisms of AZ61 magnesium alloy, the worn surfaces after wear tests were analyzed by SEM and energy-dispersive X-ray spectrometer (EDS). Based on the results obtained, die channel angles have significant influences on the grain refinements and wear behaviors of the samples. Decreasing channel angles of the ES die will not only refine the microstructures of magnesium alloys effectively and improve their harnesses, but also improve their wear resistance as decreasing channel angles results in higher friction coefficients and wear rates. With the increase in applied loads and frequencies, wear mechanisms change from mild wear (adhesion, abrasion and oxidation) to severe wear (delamination, plastic deformation and melting). In summary, the wear resistance of ES-processed AZ61 magnesium alloy could be improved by decreasing channel angles of ES dies.
Friction and wear performance of bearing ball sliding against diamond-like carbon coatings
NASA Astrophysics Data System (ADS)
Wu, Shenjiang; Kousaka, Hiroyuki; Kar, Satyananda; Li, Dangjuan; Su, Junhong
2017-01-01
We have studied the tribological properties of bearing steel ball (Japan standard, SUJ2) sliding against tetrahedral amorphous carbon (ta-C) coatings and amorphous hydrogenated carbon (a-C:H) coatings. The reciprocating sliding testes are performed with ball-on-plate friction tester in ambient air condition. Analysis of friction coefficient, wear volume and microstructure in wear scar are carried out using optical microscopy, atom force morphology (AFM) and Raman spectroscopy. The results show the SUJ2 on ta-C coating has low friction coefficient (around 0.15) but high wear loss. In contrast, the low wear loss of SUJ2 on a-C:H coating with high (around 0.4) and unsteady friction coefficient. Some Fe2O3, FeO and graphitization have been found on the wear scar of SUJ2 sliding against ta-C coating. Nearly no oxide materials exist on the wear scar of SUJ2 against a-C:H coating. The mechanism and hypothesis of the wear behavior have been investigated according to the measurement results. This study will contribute to proper selection and understand the tribological performance of bearing steels against DLC coatings.
Keating, J T; Wang, H H
2001-04-25
The current study was conducted to determine the significance of a diagnosis of atypical squamous cells of undetermined significance (ASCUS) in perimenopausal and postmenopausal women. The reports for all Papanicolaou (Pap) smears viewed in the study institution's cytology laboratory over a 6-month period were reviewed. Women were divided into premenopausal (age < or = 45 years), perimenopausal (ages 46-54 years), and postmenopausal (age > or = 55 years) categories. Slide review and 2-year follow-up were obtained for selected cases diagnosed as ASCUS. ASCUS cases among the perimenopausal women were compared with an age-matched control group. The total number of abnormal Pap smears in the premenopausal, perimenopausal, and postmenopausal categories were 770 (6.8%), 104 (4.3%), and 67 (2.9%), with 482, 83, and 41 diagnoses of ASCUS, respectively. The ratio of ASCUS to squamous intraepithelial lesions (SIL) was 2.2 overall and 1.9, 7.5, and 4.1, respectively, for each group (P < 0.001). The positive predictive value for a diagnosis of SIL on subsequent Pap smears or biopsies was 22%, 12.2%, and 29.7%, respectively. Slide review showed that the premenopausal ASCUS cases appeared to have a higher percentage of nuclear-cytoplasmic ratio increase and nuclear membrane irregularities compared with the other categories (P = 0.03 and P = 0.02, respectively) and the perimenopausal group was found to have more ASCUS in metaplastic cells (P = 0.03). In perimenopausal women, slides diagnosed as ASCUS demonstrated more air-drying artifact than the control group (P = 0.004) but had less obvious atrophy (P = 0.01). Despite a decreased abnormality rate with increasing age, the results of the current study show that the perimenopausal and postmenopausal groups appear to have elevated ASCUS-to-SIL ratios. ASCUS appears to have a particularly low positive predictive value for SIL in perimenopausal women, and therefore most likely is overcalled in this age group. This may be attributable in part to air-drying artifact and subtle atrophic changes.
Lubrication and failure mechanisms of molybdenum disulfide films. 1: Effect of atmosphere
NASA Technical Reports Server (NTRS)
Fusaro, R. L.
1978-01-01
Friction, wear, and wear lives of rubbed molybdenum disulfide (MoS2 films applied to sanded 440C HT steel surfaces were evaluated in moist air, dry air, and dry argon. Optical microscope observations were made as a function of sliding distance to determine the effect of moisture and oxygen on the lubricating and failure mechanisms of MoS2 films. In general, the lubrication process consisted of the formation of a thin, metallic colored, coalesced film of MoS2 that flowed between the surfaces in relative motion. In air, failure was due to the transformation of the metallic colored, coalesced films to a black, powdery material. Water in the air appeared to accelerate the transformation rate. In argon, no transformation of MoS2 was observed with the microscope, but cracking and spalling of the coalesced film occurred and resulted in the gradual depletion of the film.
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Ferrante, J.
1979-01-01
The wear of pure iron in sliding contact with hardened M-2 tool steel was measured for a series of synthetic diester fluids, both with and without a zinc dialkyl dithiophosphate (ZDP) antiwear additive, as test lubricants. Selected wear scars were analyzed by an Auger emission spectroscopy (AES) depth profiling technique in order to assess the surface film elemental composition. The ZDP was an effective antiwear additive for all the diesters except dibutyl oxalate and dibutyl sebacate. The high wear measured for the additive-containing oxalate was related to corrosion; the higher wear measured for the additive-containing sebacate was due to an oxygen interaction. The AES of dibutyl sebacate surfaces run in dry air and in dry nitrogen showed large differences only in the amount of oxygen present. The AES of worn surfaces where the additive was effective showed no zinc, only a little phosphorus, and large amounts of sulfur.
Using the Clear Communication Index to Improve Materials for a Behavioral Intervention.
Porter, Kathleen J; Alexander, Ramine; Perzynski, Katelynn M; Kruzliakova, Natalie; Zoellner, Jamie M
2018-02-08
Ensuring that written materials used in behavioral interventions are clear is important to support behavior change. This study used the Clear Communication Index (CCI) to assess the original and revised versions of three types of written participant materials from the SIPsmartER intervention. Materials were revised based on original scoring. Scores for the entire index were significantly higher among revised versions than originals (57% versus 41%, p < 0.001); however, few revised materials (n = 2 of 53) achieved the benchmark of ≥90%. Handouts scored higher than worksheets and slide sets for both versions. The proportion of materials scored as having "a single main message" significantly increased between versions for worksheets (7% to 57%, p = 0.003) and slide sets (33% to 67%, p = 0.004). Across individual items, most significant improvements were in Core, with four-items related to the material having a single main message. Findings demonstrate that SIPsmartER's revised materials improved after CCI-informed edits. They advance the evidence and application of the CCI, suggesting it can be effectively used to support improvement in clarity of different types of written materials used in behavioral interventions. Implications for practical considerations of using the tool and suggestions for modifications for specific types of materials are presented.
Wear Behavior of Medium Carbon Steel with Biomimetic Surface Under Starved Lubricated Conditions
NASA Astrophysics Data System (ADS)
Zhang, Zhihui; Shao, Feixian; Liang, Yunhong; Lin, Pengyu; Tong, Xin; Ren, Luquan
2017-07-01
Friction and wear under starved lubrication condition are both key life-related factors for mechanical performance of many structural parts. In this paper, different surface morphologies on medium carbon steel were fabricated using laser, inspired by the surface coupling effect of biological system. The friction and sliding wear behaviors of biomimetic specimens (characterized by convex and concave units on the specimen surface) were studied under starved lubrication condition. The stress distribution on different sliding surfaces under sliding friction was studied using finite element method. The results showed that the tribological performance of studied surfaces under starved lubrication condition depended not only on the surface morphology but also on the structure of biomimetic units below surface (subsurface structure). The friction coefficient of biomimetic surface was effectively reduced by the concave unit depth, while the refined microstructure with higher hardness led to the much better wear resistance. In addition to lubricant reserving and wear debris trapping effect derived from the surface concave morphology, it was believed that the well-formed subsurface structure of biomimetic units could carry much heavy loads against tribopair, which enhanced the function of surface topography and resulted in complementary lubrication in the wear contact area. The uniform stress distribution on the entire biomimetic surface also played an important role in stabilizing the friction coefficient and reducing the wear cracks.
NASA Astrophysics Data System (ADS)
Liang, Ji; Yuan, Xiaohui; Yuan, Yanbin; Chen, Zhihuan; Li, Yuanzheng
2017-02-01
The safety and stability of hydraulic turbine regulating system (HTRS) in hydropower plants become increasingly important since the rapid development and the broad application of hydro energy technology. In this paper, a novel mathematical model of Francis hydraulic turbine regulating system with a straight-tube surge tank based on a few state-space equations is introduced to study the dynamic behaviors of the HTRS system, where the existence of possible unstable oscillations of this model is studied extensively and presented in the forms of the bifurcation diagram, time waveform plot, phase trajectories, and power spectrum. To eliminate these undesirable behaviors, a specified fuzzy sliding mode controller is designed. In this hybrid controller, the sliding mode control law makes full use of the proposed model to guarantee the robust control in the presence of system uncertainties, while the fuzzy system is applied to approximate the proper gains of the switching control in sliding mode technique to reduce the chattering effect, and particle swarm optimization is developed to search the optimal gains of the controller. Numerical simulations are presented to verify the effectiveness of the designed controller, and the results show that the performances of the nonlinear HTRS system assisted with the proposed controller is much better than that with the commonly used optimal PID controller.
Moore, Diane E.; Byerlee, J.D.
1990-01-01
Many of the secondary fault structures developed during triaxial friction experiments have been generally correlated with the structures of natural fault zones. Therefore, any physical differences that can be found between laboratory samples that slide stably and those that show stick-slip motion may help to identify the cause of earthquakes. We have examined petrographically the run products of many triaxial friction experiments using clayey and quartzofeldspathic gouges, which comprise the principal types of natural fault gouge material. The examined samples were tested under a wide range of temperature, confining and fluid pressure, and velocity conditions. The clayey and quartzofeldspathic gouges show some textural differences, owing to their different mineral contents and grain sizes and shapes. In the clayey gouges, for example, a clay mineral fabric and kink band sets are commonly developed, whereas in the quartzofeldspathic gouges fracturing and crushing of the predominately quartz and feldspar grains are important processes. For both types of gouge, however, and whatever the pressure-temperature-velocity conditions of the experiments, the transition from stable sliding to stick-slip motion is correlated with: (i) a change from pervasive deformation of the gouge layer to localized slip in subsidiary shears; and (ii) an increase in the angle betweem the shears that crosscut the gouge layer (Riedel shears) and ones that form along the gouge-rock cylinder boundaries (boundary shears). This suggests that the localization of shear within a fault zone combined with relatively high Riedel-shear angles are somehow connected with earthquakes. Secondary fracture sets similar to Riedel shears have been identified at various scales in major strike-slip faults such as the San Andreas of the western United States (Wallace, 1973) and the Luhuo and Fuyun earthquake faults of China (Deng and Zhang, 1984; Deng et al., 1986). The San Andreas also contains locked and creeping sections that correspond to the stick-slip and stably sliding experimental samples, respectively. We plan to study the physical structure of the San Andreas fault, to see if the experimentally observed differences related to sliding behavior can also be distinguished in the field. ?? 1990.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Definitions. 1207.3 Section 1207.3 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... use means behavior on swimming pool slides as disclosed by the manufacturer, as specified in this part...
Viscous friction between crystalline and amorphous phase of dragline silk.
Patil, Sandeep P; Xiao, Senbo; Gkagkas, Konstantinos; Markert, Bernd; Gräter, Frauke
2014-01-01
The hierarchical structure of spider dragline silk is composed of two major constituents, the amorphous phase and crystalline units, and its mechanical response has been attributed to these prime constituents. Silk mechanics, however, might also be influenced by the resistance against sliding of these two phases relative to each other under load. We here used atomistic molecular dynamics (MD) simulations to obtain friction forces for the relative sliding of the amorphous phase and crystalline units of Araneus diadematus spider silk. We computed the coefficient of viscosity of this interface to be in the order of 10(2) Ns/m(2) by extrapolating our simulation data to the viscous limit. Interestingly, this value is two orders of magnitude smaller than the coefficient of viscosity within the amorphous phase. This suggests that sliding along a planar and homogeneous surface of straight polyalanine chains is much less hindered than within entangled disordered chains. Finally, in a simple finite element model, which is based on parameters determined from MD simulations including the newly deduced coefficient of viscosity, we assessed the frictional behavior between these two components for the experimental range of relative pulling velocities. We found that a perfectly relative horizontal motion has no significant resistance against sliding, however, slightly inclined loading causes measurable resistance. Our analysis paves the way towards a finite element model of silk fibers in which crystalline units can slide, move and rearrange themselves in the fiber during loading.
Viscous Friction between Crystalline and Amorphous Phase of Dragline Silk
Patil, Sandeep P.; Xiao, Senbo; Gkagkas, Konstantinos; Markert, Bernd; Gräter, Frauke
2014-01-01
The hierarchical structure of spider dragline silk is composed of two major constituents, the amorphous phase and crystalline units, and its mechanical response has been attributed to these prime constituents. Silk mechanics, however, might also be influenced by the resistance against sliding of these two phases relative to each other under load. We here used atomistic molecular dynamics (MD) simulations to obtain friction forces for the relative sliding of the amorphous phase and crystalline units of Araneus diadematus spider silk. We computed the coefficient of viscosity of this interface to be in the order of 102 Ns/m2 by extrapolating our simulation data to the viscous limit. Interestingly, this value is two orders of magnitude smaller than the coefficient of viscosity within the amorphous phase. This suggests that sliding along a planar and homogeneous surface of straight polyalanine chains is much less hindered than within entangled disordered chains. Finally, in a simple finite element model, which is based on parameters determined from MD simulations including the newly deduced coefficient of viscosity, we assessed the frictional behavior between these two components for the experimental range of relative pulling velocities. We found that a perfectly relative horizontal motion has no significant resistance against sliding, however, slightly inclined loading causes measurable resistance. Our analysis paves the way towards a finite element model of silk fibers in which crystalline units can slide, move and rearrange themselves in the fiber during loading. PMID:25119288
NASA Astrophysics Data System (ADS)
Hulikal, Srivatsan; Lapusta, Nadia; Bhattacharya, Kaushik
2018-07-01
Friction in static and sliding contact of rough surfaces is important in numerous physical phenomena. We seek to understand macroscopically observed static and sliding contact behavior as the collective response of a large number of microscopic asperities. To that end, we build on Hulikal et al. (2015) and develop an efficient numerical framework that can be used to investigate how the macroscopic response of multiple frictional contacts depends on long-range elastic interactions, different constitutive assumptions about the deforming contacts and their local shear resistance, and surface roughness. We approximate the contact between two rough surfaces as that between a regular array of discrete deformable elements attached to a elastic block and a rigid rough surface. The deformable elements are viscoelastic or elasto/viscoplastic with a range of relaxation times, and the elastic interaction between contacts is long-range. We find that the model reproduces the main macroscopic features of evolution of contact and friction for a range of constitutive models of the elements, suggesting that macroscopic frictional response is robust with respect to the microscopic behavior. Viscoelasticity/viscoplasticity contributes to the increase of friction with contact time and leads to a subtle history dependence. Interestingly, long-range elastic interactions only change the results quantitatively compared to the meanfield response. The developed numerical framework can be used to study how specific observed macroscopic behavior depends on the microscale assumptions. For example, we find that sustained increase in the static friction coefficient during long hold times suggests viscoelastic response of the underlying material with multiple relaxation time scales. We also find that the experimentally observed proportionality of the direct effect in velocity jump experiments to the logarithm of the velocity jump points to a complex material-dependent shear resistance at the microscale.
The Tribological Difference between Biomedical Steels and CoCrMo-Alloys
Fischer, Alfons; Weiß, Sabine; Wimmer, Markus A.
2012-01-01
In orthopedic surgery different self-mating metal couples are used for sliding wear applications. Despite the fact that in mechanical engineering self-mating austenitic alloys often lead to adhesion and seizure in biomedical engineering the different grades of Co-base alloys show good clinical results e.g. as hip joints. The reason stems from the fact that they generate a so-called tribomaterial during articulation, which consists of a mixture of nanometer small metallic grains and organic substances from the interfacial medium, which act as boundary lubricant. Even though stainless steels also generate such a tribomaterial they were ruled out from the beginning already in the 1950 as “inappropriate”. On the basis of materials with a clinical track record this contribution shows that the cyclic creep characteristics within the shear zone underneath the tribomaterial are another important criterion for a sufficient wear behavior. By means of sliding wear and torsional fatigue tests followed by electron microscopy it is shown, that austenitic materials generate wear particles of either nano- or of microsize. The latter are produced by crack initiation and propagation within the shear fatigue zone which is related to the formation of subsurface dislocation cells and, therefore, by the fact that a Ni-containing CrNiMo solid solution allows for wavy-slip. In contrast to this a Ni-free CrMnMo solid solution with further additions of C and N only shows planar slip. This leads to the formation of nanosize wear particles and distinctly improves the wear behavior. Still the latter does not fully achieve that of CoCrMo, which also shows solely planar-slip behavior. This explains why for metallurgical reasons the Ni-containing 316L-type of steels had to fail in such boundary lubricated sliding wear tribosystems. PMID:22498283
NASA Astrophysics Data System (ADS)
Lv, Wenping; Wu, Ren'an
2013-03-01
A computational investigation was carried out to understand the aggregation of nanoscale graphene with two typical pathways of stacking assembly and sliding assembly in water. The interfacial-organized monolayer water film (MWF) induced ``two-step'' aggregation of nanographene in both stacking and sliding assembly pathways was reported for the first time. By means of potential mean forces (PMFs) calculation, no energy barrier was observed during the sliding assembly of two graphene nanosheets, while the PMF profiles could be impacted by the contact forms of nanographene and the MWF within the interplate of two graphene nanosheets. To explore the potential physical basis of the ``hindering role'' of self-organized interfacial water, the dynamical and structural properties as well as the status of hydrogen bonds (H-bonds) for interfacial water were investigated. We found that the compact, ordered structure and abundant H-bonds of the MWF could be taken as the fundamental aspects of the ``hindering role'' of interfacial water for the hydrophobic assembly of nanographene. These findings are displaying a potential to further understand the hydrophobic assembly which mostly dominate the behaviors of nanomaterials, proteins etc. in aqueous solutions.A computational investigation was carried out to understand the aggregation of nanoscale graphene with two typical pathways of stacking assembly and sliding assembly in water. The interfacial-organized monolayer water film (MWF) induced ``two-step'' aggregation of nanographene in both stacking and sliding assembly pathways was reported for the first time. By means of potential mean forces (PMFs) calculation, no energy barrier was observed during the sliding assembly of two graphene nanosheets, while the PMF profiles could be impacted by the contact forms of nanographene and the MWF within the interplate of two graphene nanosheets. To explore the potential physical basis of the ``hindering role'' of self-organized interfacial water, the dynamical and structural properties as well as the status of hydrogen bonds (H-bonds) for interfacial water were investigated. We found that the compact, ordered structure and abundant H-bonds of the MWF could be taken as the fundamental aspects of the ``hindering role'' of interfacial water for the hydrophobic assembly of nanographene. These findings are displaying a potential to further understand the hydrophobic assembly which mostly dominate the behaviors of nanomaterials, proteins etc. in aqueous solutions. Electronic supplementary information (ESI) available: The evolution of interaction energy for two graphene nanosheets assembly in stacking (a) and sliding (b) pathway was plotted in Fig. S1. The time evolution of three dimension distance for stacking assembly of two graphene nanosheets with the edge-edge orientation of 45° was plotted in Fig. S2. The initial orientations of graphene nanosheets in three simulations (edge-edge distance in x-direction (dx) was 0.3 nm, but in z-direction (dz) was 0.0 nm, 0.4 nm and 0.7 nm, respectively) were shown in Fig. S3. The snapshots of the evolution of hydration shells during the sliding assembly of nanographene were shown in Fig. S4, with the separation of two graphene nanosheets in z-direction is (a) 0 nm and (b) 0.7 nm, respectively. The process of two graphene nanosheets assembly in stacking pathway was shown in Movie S1 as video. The process of two graphene nanosheets (with a separation of 0.7 nm in normal direction) assembly in sliding pathway was shown in Movie S2 as video. The dynamical evolution of interfacial water during the sliding assembly of nanographene was shown in Movie S3 as video. The process of extruding the monolayer water film (MWF) out of the interplate of two graphene nanosheets was shown in Movie S4 as video. Movie S5 displays that the graphene-water-graphene sandwiched structure was successfully maintained during a 10 ns MD simulation. See DOI: 10.1039/c3nr33447c
Demonstration of the Feasibility of High Temperature Bearing Lubrication From Carbonaceous Gases
NASA Technical Reports Server (NTRS)
Blanchet, Thierry A.; Sawyer, W. Gregory
1996-01-01
Research has been conducted on silicon nitride pin-on-disk sliding contacts at temperatures of up to 520 C, and four-ball rolling contacts with silicon nitride balls and 52100 steel or silicon nitride races at 590 C. These tests were conducted in a variety of gaseous environments in order to determine the effects of simulated engine exhaust gas on the carbonaceous gas decomposition lubrication scheme. In rolling tests with steel races and exhaust gas the wear track depth was roughly half that of tests run in nitrogen gas alone. The deposition of lubricous microcrystalline graphitic carbon on the rolling surfaces, generated from the carbon monoxide within the exhaust gas mixture, was verified by microfocused Raman spectroscopy. Ten-fold reductions in rolling wear could be achieved by the exhaust gas atmosphere in cases where water vapor was removed or not present. The exhaust gas mixture alone was not found to provide any lubricating effect on silicon nitride sliding contacts, where the rate of wear greatly exceeds the rate of carbon deposition. Directed admixture of acetylene (as low as 5% of the exhaust gas flow rates), has provided reductions in both wear volume and coefficient of friction by factors of 60X and 20X respectively for sliding contacts during the initial 80 m of sliding distance. Exhaust gas atmosphere with the acetylene admixture provided 65OX reductions in steady state wear rate compared to that measured for sliding contacts in dry N2. Such acetylene admixture also augments the ability of the exhaust gas atmosphere to lubricate high-temperature rolling contacts, with up to 25-fold reductions in wear track depth compared to those measured in the presence of N2 alone. In addition to providing some lubricating benefit itself, an important potential role of the exhaust gas from rich mixtures would be to shield bearings from 02. Such shielding enables surface deposition of lubricous pyrolytic carbon from the acetylene admixture, instead of combustion, rendering feasible the continuously replenished solid lubrication of high-temperature bearing surfaces.
NASA Technical Reports Server (NTRS)
Dellacorte, Christopher; Thomas, Fransua; Leak, Olivia Ann
2015-01-01
A series of pin-on-disk sliding wear tests were undertaken to identify candidate materials for a pair of lightly loaded timing gears operating under highly humid conditions. The target application involves water purification and thus precludes the use of oil, grease and potentially toxic solid lubricants. The baseline sliding pair is austenitic stainless steel operating against a carbon filled polyimide. The test load and sliding speed (4.9 N, 2.7 m/s) were chosen to represent average contact conditions of the meshing gear teeth. In addition to the baseline materials, the hard superelastic NiTiNOL 60 (60NiTi) was slid against itself, against the baseline polyimide, and against 60NiTi onto which a commercially deposited dry film lubricant (DFL) was applied. The alternate materials were evaluated as potential replacements to achieve a longer wear life and improved dimensional stability for the timing gear application. An attempt was also made to provide solid lubrication to self-mated 60NiTi by rubbing the polyimide against the disk wear track outside the primary 60NiTi-60NiTi contact, a method named stick or transfer-film lubrication. The selected test conditions gave repeatable friction and wear data and smooth sliding surfaces for the baseline materials similar to those in the target application. Friction and wear for self-mated stainless steel were high and erratic. Self-mated 60NiTi gave acceptably low friction (approx. 0.2) and modest wear but the sliding surfaces were rough and potentially unsuitable for the gear application. Tests in which 60NiTi pins were slid against DFL coated 60NiTi and DFL coated stainless steel gave low friction and long wear life. The use of stick lubrication via the secondary polyimide pin provided effective transfer film lubrication to self-mated 60NiTi tribological specimens. Using this approach, friction levels were equal or lower than the baseline polyimide-stainless combination and wear was higher but within data scatter observed in these preliminary tests. Based upon these results, self-mated 60NiTi gear teeth utilizing solid lubrication, is a reasonable approach for the target application.
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Thomas, Fransua; Leak, Olivia Ann
2015-01-01
A series of pin-on-disk sliding wear tests were undertaken to identify candidate materials for a pair of lightly loaded timing gears operating under highly humid conditions. The target application involves water purification and thus precludes the use of oil, grease and potentially toxic solid lubricants. The baseline sliding pair is austenitic stainless steel operating against a carbon filled polyimide. The test load and sliding speed (4.9N, 2.7ms) were chosen to represent average contact conditions of the meshing gear teeth. In addition to the baseline materials, the hard superelastic NiTiNOL 60 (60NiTi) was slid against itself, against the baseline polyimide, and against 60NiTi onto which a commercially deposited dry film lubricant (DFL) was applied. The alternate materials were evaluated as potential replacements to achieve a longer wear life and improved dimensional stability for the timing gear application. An attempt was also made to provide solid lubrication to self-mated 60NiTi by rubbing the polyimide against the disk wear track outside the primary 60NiTi-60NiTi contact, a method named stick or transfer-film lubrication. The selected test conditions gave repeatable friction and wear data and smooth sliding surfaces for the baseline materials similar to those in the target application. Friction and wear for self-mated stainless steel were high and erratic. Self-mated 60NiTi gave acceptably low friction (0.2) and modest wear but the sliding surfaces were rough and potentially unsuitable for the gear application. Tests in which 60NiTi pins were slid against DFL coated 60NiTi and DFL coated stainless steel gave low friction and long wear life. The use of stick lubrication via a secondary polyimide pin provided effective transfer film lubrication to self-mated 60NiTi tribological specimens. Using this approach, friction levels were equal or lower than the baseline polyimide-stainless combination and wear was higher but within data scatter observed in these preliminary tests. Based upon these results, self-mated 60NiTi gear teeth utilizing solid lubrication, is a reasonable approach for the target application.
Rock Slide Risk Assessment: A Semi-Quantitative Approach
NASA Astrophysics Data System (ADS)
Duzgun, H. S. B.
2009-04-01
Rock slides can be better managed by systematic risk assessments. Any risk assessment methodology for rock slides involves identification of rock slide risk components, which are hazard, elements at risk and vulnerability. For a quantitative/semi-quantitative risk assessment for rock slides, a mathematical value the risk has to be computed and evaluated. The quantitative evaluation of risk for rock slides enables comparison of the computed risk with the risk of other natural and/or human-made hazards and providing better decision support and easier communication for the decision makers. A quantitative/semi-quantitative risk assessment procedure involves: Danger Identification, Hazard Assessment, Elements at Risk Identification, Vulnerability Assessment, Risk computation, Risk Evaluation. On the other hand, the steps of this procedure require adaptation of existing or development of new implementation methods depending on the type of landslide, data availability, investigation scale and nature of consequences. In study, a generic semi-quantitative risk assessment (SQRA) procedure for rock slides is proposed. The procedure has five consecutive stages: Data collection and analyses, hazard assessment, analyses of elements at risk and vulnerability and risk assessment. The implementation of the procedure for a single rock slide case is illustrated for a rock slope in Norway. Rock slides from mountain Ramnefjell to lake Loen are considered to be one of the major geohazards in Norway. Lake Loen is located in the inner part of Nordfjord in Western Norway. Ramnefjell Mountain is heavily jointed leading to formation of vertical rock slices with height between 400-450 m and width between 7-10 m. These slices threaten the settlements around Loen Valley and tourists visiting the fjord during summer season, as the released slides have potential of creating tsunami. In the past, several rock slides had been recorded from the Mountain Ramnefjell between 1905 and 1950. Among them, four of the slides caused formation of tsunami waves which washed up to 74 m above the lake level. Two of the slides resulted in many fatalities in the inner part of the Loen Valley as well as great damages. There are three predominant joint structures in Ramnefjell Mountain, which controls failure and the geometry of the slides. The first joint set is a foliation plane striking northeast-southwest and dipping 35Ë -40Ë to the east-southeast. The second and the third joint sets are almost perpendicular and parallel to the mountain side and scarp, respectively. These three joint sets form slices of rock columns with width ranging between 7-10 m and height of 400-450 m. It is stated that the joints in set II are opened between 1-2 m, which may bring about collection of water during heavy rainfall or snow melt causing the slices to be pressed out. It is estimated that water in the vertical joints both reduces the shear strength of sliding plane and causes reduction of normal stress on the sliding plane due to formation of uplift force. Hence rock slides in Ramnefjell mountain occur in plane failure mode. The quantitative evaluation of rock slide risk requires probabilistic analysis of rock slope stability and identification of consequences if the rock slide occurs. In this study failure probability of a rock slice is evaluated by first-order reliability method (FORM). Then in order to use the calculated probability of failure value (Pf) in risk analyses, it is required to associate this Pf with frequency based probabilities (i.ePf / year) since the computed failure probabilities is a measure of hazard and not a measure of risk unless they are associated with the consequences of the failure. This can be done by either considering the time dependent behavior of the basic variables in the probabilistic models or associating the computed Pf with frequency of the failures in the region. In this study, the frequency of previous rock slides in the previous century in Remnefjell is used for evaluation of frequency based probability to be used in risk assessment. The major consequence of a rock slide is generation of a tsunami in the lake Loen, causing inundation of residential areas around the lake. Risk is assessed by adapting damage probability matrix approach, which is originally developed for risk assessment for buildings in case of earthquake.
Justin Paul Ziegler; Chad Hoffman; Michael Battaglia; William Mell
2017-01-01
Restoration treatments in dry forests of the western US often attempt silvicultural practices to restore the historical characteristics of forest structure and fire behavior. However, it is suggested that a reliance on non-spatial metrics of forest stand structure, along with the use of wildland fire behavior models that lack the ability to handle complex structures,...
Impact of spatially correlated pore-scale heterogeneity on drying porous media
NASA Astrophysics Data System (ADS)
Borgman, Oshri; Fantinel, Paolo; Lühder, Wieland; Goehring, Lucas; Holtzman, Ran
2017-07-01
We study the effect of spatially-correlated heterogeneity on isothermal drying of porous media. We combine a minimal pore-scale model with microfluidic experiments with the same pore geometry. Our simulated drying behavior compares favorably with experiments, considering the large sensitivity of the emergent behavior to the uncertainty associated with even small manufacturing errors. We show that increasing the correlation length in particle sizes promotes preferential drying of clusters of large pores, prolonging liquid connectivity and surface wetness and thus higher drying rates for longer periods. Our findings improve our quantitative understanding of how pore-scale heterogeneity impacts drying, which plays a role in a wide range of processes ranging from fuel cells to curing of paints and cements to global budgets of energy, water and solutes in soils.
Studies on centrifugal clutch judder behavior and the design of frictional lining materials
NASA Astrophysics Data System (ADS)
Li, Tse-Chang; Huang, Yu-Wen; Lin, Jen-Fin
2016-01-01
This study examines the judder behavior of a centrifugal clutch from the start of hot spots in the conformal contact, then the repeated developments of thermoelastic instability, and finally the formation of cyclic undulations in the vibrations, friction coefficient and torque. This behavior is proved to be consistent with the testing results. Using the Taguchi method, 18 kinds of frictional lining specimens were prepared in order to investigate their performance in judder resistance and establish a relationship between judder behavior and the Ts/Td (Ts: static torque; Td: dynamic torque) and dμ/dVx (μ: friction coefficient; Vx: relative sliding velocity of frictional lining and clutch drum) parameters. These specimens are also provided to examine the effects and profitability with regard to the centrifugal clutch, and find the relative importance of the various control factors. Theoretical models for the friction coefficient (μ), the critical sliding velocity (Vc) with clutch judder, and the contact pressure ratio p* /pbar (p*: pressure undulation w.r.t. pbar; pbar: mean contact pressure) and temperature corresponding to judder behavior are developed. The parameters of the contact pressure ratio and temperature are shown to be helpful to explain the occurrence of judder. The frictional torque and the rotational speeds of the driveline, clutch, and clutch drum as functions of engagement time for 100 clutch cycles are obtained experimentally to evaluate dμ/dVx and Ts/Td. A sharp rise in the maximum p* /pbar occurred when the relative sliding velocity reached the critical velocity, Vc. An increase in the maximum p* /pbar generally led to an increase of the (initially negative) dμ/dVx value, and thus the severity of judder. The fluctuation intensity of dμ/dVx becomes a governing factor of the growth of dμ/dVx itself in the engagement process. The mean values of dμ/dVx and Ts/Td for the clutching tests with 100 cycles can be roughly divided into three groups dependent on the fluctuation intensities of these two parameters, for each of which there is a linear relationship.
Argibay, N.; Chandross, M.; Cheng, S.; ...
2016-11-21
A correlation is established between the macro-scale friction regimes of metals and a transition between two dominant atomistic mechanisms of deformation. Metals tend to exhibit bi-stable friction behavior—low and converging or high and diverging. These general trends in behavior are shown to be largely explained using a simplified model based on grain size evolution, as a function of contact stress and temperature, and are demonstrated for self-mated pure copper and gold sliding contacts. Specifically, the low-friction regime (where µ < 0.5) is linked to the formation of ultra-nanocrystalline surface films (10–20 nm), driving toward shear accommodation by grain boundary sliding.more » Above a critical combination of stress and temperature—demonstrated to be a material property—shear accommodation transitions to dislocation dominated plasticity and high friction, with µ > 0.5. We utilize a combination of experimental and computational methods to develop and validate the proposed structure–property relationship. As a result, this quantitative framework provides a shift from phenomenological to mechanistic and predictive fundamental understanding of friction for crystalline materials, including engineering alloys.« less
Constituent Effects on the Stress-Strain Behavior of Woven Melt-Infiltrated SiC Composites
NASA Technical Reports Server (NTRS)
Morscher, Gregory N.; Eldridge, Jeff I.; Levine, Stanley (Technical Monitor)
2001-01-01
The stress-strain behavior of 2D woven SiC fiber reinforced, melt-infiltrated SiC matrix composites with BN interphases were studied for composites fabricated with different fiber tow ends per unit length, different composite thickness, and different numbers of plies. In general, the stress-strain behavior, i.e., the 'knee' in the curve and the final slope of the stress-strain curve, was controlled by the volume fraction of fibers. Some of the composites exhibited debonding and sliding in between the interphase and the matrix rather than the more common debonding and sliding interface between the fiber and the interphase. Composites that exhibited this 'outside debonding' interface, in general, had lower elastic moduli and higher ultimate strains as well as longer pull-out lengths compared to the 'inside debonding' interface composites. Stress-strain curves were modeled where matrix crack formation as a function of stress was approximated from the acoustic emission activity and the measured crack density from the failed specimens. Interfacial shear strength measurements from individual fiber push-in tests were in good agreement with the interfacial shear strength values used to model the stress-strain curves.
NASA Technical Reports Server (NTRS)
Mishina, H.; Buckley, D. H.
1984-01-01
Friction experiments were conducted for the semiconductors silicon and gallium arsenide in contact with pure metals. Polycrystalline titanium, tantalum, nickel, palladium, and platinum were made to contact a single crystal silicon (111) surface. Indium, nickel, copper, and silver were made to contact a single crystal gallium arsenide (100) surface. Sliding was conducted both in room air and in a vacuum of 10 to the minus 9th power torr. The friction of semiconductors in contact with metals depended on a Schottky barrier height formed at the metal semiconductor interface. Metals with a higher barrier height on semiconductors gave lower friction. The effect of the barrier height on friction behavior for argon sputtered cleaned surfaces in vacuum was more specific than that for the surfaces containing films in room air. With a silicon surface sliding on titanium, many silicon particles back transferred. In contrast, a large quantity of indium transferred to the gallium arsenide surface.
Nature of the Surface and Its Effect on Solid-state Interactions
NASA Technical Reports Server (NTRS)
Georges, J. M.
1984-01-01
An important aspect of the friction and wear of solids is the nature and the mechanical behavior of the surface films. A description of the mechanical, physical, and chemical behavior of surface films is achieved by an investigation of boundary lubrication. Two major points are demonstrated. First, the sliding of two solid surfaces under boundary lubricating conditions creates third bodies in the interface. Second, the nature and the evolution of the interface are dictated by the colloidal behavior of the products generated. To illustrate these two propositions, some recent work is presented.
NASA Astrophysics Data System (ADS)
Purohit, A.; Satapathy, A.
2017-02-01
Use of industrial wastes, such as slag and sludge particles, as filler in polymers is not very common in the field of composite research. Therefore in this paper, a comparison of mechanical characteristics of epoxy based composites filled with LD sludge, BF slag and LD slag (wastes generated in iron and steel industries) were presented. A comparative study among these composites in regard to their dry sliding wear characteristics under similar test conditions was also included. Composites with different weight proportions (0, 5, 10, 15 and 20 wt.%) of LD sludge were fabricated by solution casting technique. Mechanical properties were evaluated as per ASTM test standards and sliding wear test was performed following a design of experiment approach based on Taguchi’s orthogonal array. The test results for epoxy-LD sludge composites were compared with those of epoxy-BF slag and epoxy-LD slag composites reported by previous investigators. The comparison reveals that epoxy filled with LD sludge exhibits superior mechanical and wear characteristics among the three types of composites considered in this study.
Wear study of Al-SiC metal matrix composites processed through microwave energy
NASA Astrophysics Data System (ADS)
Honnaiah, C.; Srinath, M. S.; Prasad, S. L. Ajit
2018-04-01
Particulate reinforced metal matrix composites are finding wider acceptance in many industrial applications due to their isotropic properties and ease of manufacture. Uniform distribution of reinforcement particulates and good bonding between matrix and reinforcement phases are essential features in order to obtain metal matrix composites with improved properties. Conventional powder metallurgy technique can successfully overcome the limitation of stir casting techniques, but it is time consuming and not cost effective. Use of microwave technology for processing particulate reinforced metal matrix composites through powder metallurgy technique is being increasingly explored in recent times because of its cost effectiveness and speed of processing. The present work is an attempt to process Al-SiC metal matrix composites using microwaves irradiated at 2.45 GHz frequency and 900 W power for 10 minutes. Further, dry sliding wear studies were conducted at different loads at constant velocity of 2 m/s for various sliding distances using pin-on-disc equipment. Analysis of the obtained results show that the microwave processed Al-SiC composite material shows around 34 % of resistance to wear than the aluminium alloy.
Texturing of UHMWPE surface via NIL for low friction and wear properties
NASA Astrophysics Data System (ADS)
Suryadi Kustandi, Tanu; Choo, Jian Huei; Low, Hong Yee; Sinha, Sujeet K.
2010-01-01
Wear is a major obstacle limiting the useful life of implanted ultra-high molecular weight polyethylene (UHMWPE) components in total joint arthroplasty. It has been a continuous effort in the implant industry to reduce the frictional wear problem of UHMWPE by improving the structure, morphology and mechanical properties of the polymer. In this paper, a new paradigm that utilizes nanoimprint lithography (NIL) in producing textures on the surface of UHMWPE is proposed to efficiently improve the tribological properties of the polymer. Friction and wear experiments were conducted on patterned and controlled (non-patterned) UHMWPE surfaces using a commercial tribometer, mounted with a silicon nitride ball, under a dry-sliding condition with normal loads ranging from 60 to 200 mN. It has been shown that the patterned UHMWPE surface showed a reduction in the coefficient of friction between 8% and 35% as compared with the controlled (non-patterned) surface, depending on the magnitude of the normal load. Reciprocating wear experiments also showed that the presence of surface textures on the polymer resulted in lower wear depth and width, with minimal material transfer to the sliding surface.
The Influence of The Temperature on Dry Friction of AISI 3315 Steel Sliding Against AISI 3150 Steel
NASA Astrophysics Data System (ADS)
Odabas, D.
2018-01-01
In this paper, the effects the influence of frictional heating on the wear of AISI 3315 Steel were investigated experimentally using a pin-on-ring geometry. All the tests were carried out in air without any lubricant. In order to understand the variation in frictional coefficient and temperature with load and speed, the friction tests were carried out at a speed of 1 m/s and loads in the range 115-250 N, and at a speed range 1-4 m/s, a load of 115 N. The sliding distance was 1500 m. The bulk temperature of the specimen was measured from the interface surface at a distance of 1 mm from the contact surface by using type K thermocouples (Ni-Cr-Ni). The coefficient of friction was determined as a function of test load and speed. The steady state coefficient of friction of the test material decreases with increasing load and speed due to the oxide formation. But the unsteady state coefficient of friction increases with an increase in load and speed.
Tribological properties of nanosized calcium carbonate filled polyamide 66 nanocomposites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Itagaki, Kaito; Nishitani, Yosuke; Kitano, Takeshi
For the purpose of developing high performance tribomaterials for mechanical sliding parts such as gears, bearings and so on, nanosized calcium carbonate (nano-CaCO{sub 3}) filled polyamide 66 (PA66) nanocomposites were investigated. The nano-CaCO{sub 3} was a kind of precipitated (colloid typed) CaCO{sub 3}, and its average particle size was 40, 80 and 150 nm. Surface treatment was performed by fatty acid on the nano-CaCO{sub 3} and its volume fraction in the nanocomposite was varied from 1 to 20vol.%. These nanocomposites were melt-mixed by a twin screw extruder and injection-molded. Tribological properties were measured by two types of sliding wear testers suchmore » as ring-on-plate type and ball-on-plate type one under dry condition. The counterface, worn surface and wear debris were observed by digital microscope and scanning electron microscope. It was found that the nano-CaCO{sub 3} has a good effect on the tribological properties, although the effect on the frictional coefficient and specific wear rate is differed by the volume fraction and the type of sliding wear modes. This is attributed to the change of wear mechanisms, which is the change of form of the transfer films on the counterface and the size of wear debris. It follows from these results that PA66/nano-CaCO{sub 3} nanocomposites may be possible to be the high performance tribomaterials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freislebem, Márcia; Menezes, Caren M.; Cemin, Felipe
2014-09-15
Friction is a ubiquitous phenomenon in everyday activities spanning from vehicles where efficient brakes are mandatory up to mechanical devices where its minimum effects are pursued for energy efficiency issues. Recently, theoretical models succeed correlating the friction behavior with energy transference via phonons between sliding surfaces. Therefore, considering that the energy losses by friction are prompted through phonons, the chemical surface structure between sliding surfaces is very important to determine the friction phenomenon. In this work, we address the issue of friction between a conical diamond tip sliding on different functionalized flat steel surfaces by focusing the influence of themore » chemical bonds in the outermost layers on the sliding resistance. This geometry allows probing the coupling of the sharp tip with terminator species on the top and underneath material surface at in-depth friction measurements from 20 to 200 nm. Experimentally, the friction coefficient decreases when nitrogen atoms are substituted for oxygen in the iron network. This effect is interpreted as due to energy losses through phonons whilst lower vibrational frequency excitation modes imply lower friction coefficients and a more accurate adjustment is obtained when a theoretical model with longitudinal adsorbate vibration is used.« less
XPS analysis of the effect of fillers on PTFE transfer film development in sliding contacts
NASA Technical Reports Server (NTRS)
Blanchet, T. A.; Kennedy, F. E.; Jayne, D. T.
1993-01-01
The development of transfer films atop steel counterfaces in contact with unfilled and bronze-filled PTFE has been studied using X-ray photoelectron spectroscopy. The sliding apparatus was contained within the vacuum of the analytical system, so the effects of the native oxide, hydrocarbon, and adsorbed gaseous surface layers of the steel upon the PTFE transfer behavior could be studied in situ. For both the filled and the unfilled PTFE, cleaner surfaces promoted greater amounts of transfer. Metal fluorides, which formed at the transfer film/counterface interface, were found solely in cases where the native oxide had been removed to expose the metallic surface prior to sliding. These fluorides also were found at clean metal/PTFE interfaces formed in the absence of frictional contact. A fraction of these fluorides resulted from irradiation damage inherent in XPS analysis. PTFE transfer films were found to build up with repeated sliding passes, by a process in which strands of transfer filled in the remaining counterface area. Under these reported test conditions, the transfer process is not expected to continue atop previously deposited transfer films. The bronze-filled composite generated greater amounts of transfer than the unfilled PTFE. The results are discussed relative to the observed increase in wear resistance imparted to PTFE by a broad range of inorganic fillers.
Rheological considerations for the modelling of submarine sliding at Rockall Bank, NE Atlantic Ocean
NASA Astrophysics Data System (ADS)
Salmanidou, D. M.; Georgiopoulou, A.; Guillas, S.; Dias, F.
2018-03-01
Recent scientific research indicates that the Rockall Bank Slide Complex in the NE Atlantic Ocean has formed as the result of repetitive slope failures that can be distinguished in at least three major phases. These sliding episodes took place during and before the Last Glacial Maximum. This work attempts the modelling of each sliding episode with the incorporation of the landslide's rheological properties. The objective is to study the landslide kinematics and final deposition of each episode under a rheological framework that comes in agreement with the field observations. To do so in the present work, we use different types of rheological models to compute the total retarding stress and simulate submarine failure. The Bingham rheology and the frictional rheology are used to model the flow behavior. The scope of this approach is to understand the effect of the two classical laws in landslide kinematics. A rheological model that combines the two regimes is also used. To account for the hydrodynamic drag, the Voellmy model is employed. The results are validated against the field observations on the seabed of the Rockall Trough. The simulations show that for this particular case the Bingham rheology with a small or negligible basal friction produces the best results. The tsunamigenic potential of the episodes is also briefly examined.
The role of crystallographic texture in achieving low friction zinc oxide nanolaminate films
NASA Astrophysics Data System (ADS)
Mojekwu, Nneoma
Metal oxide nanolaminate films are potential high temperature solid lubricants due to their ability to exhibit significant plasticity when grain size is reduced to the nanometer scale, and defective growth structure is achieved by condensation of oxygen vacancies to form intrinsic stacking faults. This is in contrast to conventional microcrystalline and single crystal oxides that exhibit brittle fracture during loading in a sliding contact. This study emphasizes the additional effect of growth orientation, in particular crystallographic texture, on determining the sliding friction behavior in nanocolumnar grain zinc oxide films grown by atomic layer deposition. It was determined that zinc oxide low (0002) versus higher (101¯3) surface energy crystallographic planes influenced the sliding friction coefficient. Texturing of the (0002) grains resulted in a decreased adhesive component of friction thereby lowering the sliding friction coefficient to ˜0.25, while the friction coefficient doubled to ˜0.5 with increasing contribution of surface (101¯3) grains. In addition, the variation of the x-ray grazing incident angle from 0.5° to 5° was studied to better understand the surface grain orientation as a function of ZnO layer thickness in one versus four bilayer nanolaminates where the under layer (seed layer) was load-bearing Zn(Ti,Zr)O3.
Influence of alloying elements on friction and wear of copper
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1972-01-01
The friction and wear characteristics were determined for copper binary alloys containing 10 atomic percent aluminum, silicon, indium, and tin. A ternary alloy containing 10 atomic percent aluminum and 5 atomic percent silicon was also examined. The effectiveness of each of the alloying elements aluminum and silicon were very effective in reducing friction. Silicon, however, also reduced wear appreciably. With lubrication, silicon, indium, and tin were all effective alloying elements in reducing friction and wear from values obtained for copper. Silicon was the most effective single element in reducing friction and wear in dry sliding and with lubrication.
SLAMMER: Seismic LAndslide Movement Modeled using Earthquake Records
Jibson, Randall W.; Rathje, Ellen M.; Jibson, Matthew W.; Lee, Yong W.
2013-01-01
This program is designed to facilitate conducting sliding-block analysis (also called permanent-deformation analysis) of slopes in order to estimate slope behavior during earthquakes. The program allows selection from among more than 2,100 strong-motion records from 28 earthquakes and allows users to add their own records to the collection. Any number of earthquake records can be selected using a search interface that selects records based on desired properties. Sliding-block analyses, using any combination of rigid-block (Newmark), decoupled, and fully coupled methods, are then conducted on the selected group of records, and results are compiled in both graphical and tabular form. Simplified methods for conducting each type of analysis are also included.
NASA Astrophysics Data System (ADS)
Hajipour, Ahmad; Tavakoli, Hamidreza
2017-12-01
In this study, the dynamic behavior and chaos control of a chaotic fractional incommensurate-order financial system are investigated. Using well-known tools of nonlinear theory, i.e. Lyapunov exponents, phase diagrams and bifurcation diagrams, we observe some interesting phenomena, e.g. antimonotonicity, crisis phenomena and route to chaos through a period doubling sequence. Adopting largest Lyapunov exponent criteria, we find that the system yields chaos at the lowest order of 2.15. Next, in order to globally stabilize the chaotic fractional incommensurate order financial system with uncertain dynamics, an adaptive fractional sliding mode controller is designed. Numerical simulations are used to demonstrate the effectiveness of the proposed control method.
Johnson, Robert E; Oldroyd, Megan E; Ahmed, Saleem S; Gieseler, Henning; Lewis, Lavinia M
2010-06-01
The freeze-drying behavior and cake morphology of a model protein in an amorphous formulation were studied at varying protein concentrations using conservative (-25 degrees C) and aggressive (+25 degrees C) shelf temperatures at constant chamber pressure during primary drying. The two cycles were characterized by manometric temperature measurements (MTM) in a SMART freeze dryer that estimates the sublimation rate (dm/dt), product temperature at the freeze-drying front (T(p-MTM)) and product resistance (R(p)) during a run. The calculated sublimation rates (dm/dt) were 3-4 times faster in the aggressive cycle compared to the conservative cycle. For conservatively dried cakes R(p) increased with both dry layer thickness and protein concentration. For aggressively dried cakes (where freeze-drying occurs at the edge of microcollapse), R(p) also increased with protein concentration but was independent of the dry layer thickness. The sublimation rate was influenced by R(p), dry layer thickness and T(p-MTM) in the conservative cycle, but was governed mainly by T(p-MTM) in the aggressive cycle, where R(p) is independent of the dry layer thickness. The aggressively dried cakes had a more open and porous structure compared to their conservatively dried counterparts. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association
NASA Astrophysics Data System (ADS)
Li, Yang; He, Yongyong; Wang, Wei; Mao, Junyuan; Zhang, Lei; Zhu, Yijie; Ye, Qianwen
2018-03-01
In direct current plasma nitriding (DCPN), the treated components are subjected to a high cathodic potential, which brings several inherent shortcomings, e.g., damage by arcing and the edging effect. In active screen plasma nitriding (ASPN) processes, the cathodic potential is applied to a metal screen that surrounds the workload, and the component to be treated is placed in a floating potential. Such an electrical configuration allows plasma to be formed on the metal screen surface rather than on the component surface; thus, the shortcomings of the DCPN are eliminated. In this work, the nitrided experiments were performed using a plasma nitriding unit. Two groups of samples were placed on the table in the cathodic and the floating potential, corresponding to the DCPN and ASPN, respectively. The floating samples and table were surrounded by a steel screen. The DCPN and ASPN of the AISI 304 stainless steels are investigated as a function of the electric potential. The samples were characterized using scanning electron microscopy with energy-dispersive x-ray spectroscopy, x-ray diffraction, atomic force microscopy and transmission electron microscope. Dry sliding ball-on-disk wear tests were conducted on the untreated substrate, DCPN and ASPN samples. The results reveal that all nitrided samples successfully produced similar nitrogen-supersaturated S phase layers on their surfaces. This finding also shows the strong impact of the electric potential of the nitriding process on the morphology, chemical characteristics, hardness and tribological behavior of the DCPN and ASPN samples.
Fast response dry-type artificial molecular muscles with [c2]daisy chains
NASA Astrophysics Data System (ADS)
Iwaso, Kazuhisa; Takashima, Yoshinori; Harada, Akira
2016-06-01
Hierarchically organized myosin and actin filaments found in biological systems exhibit contraction and expansion behaviours that produce work and force by consuming chemical energy. Inspired by these naturally occurring examples, we have developed photoresponsive wet- and dry-type molecular actuators built from rotaxane-based compounds known as [c2]daisy chains (specifically, [c2]AzoCD2 hydrogel and [c2]AzoCD2 xerogel). These actuators were prepared via polycondensation between four-armed poly(ethylene glycol) and a [c2]daisy chain based on α-cyclodextrin as the host component and azobenzene as a photoresponsive guest component. The light-induced actuation arises from the sliding motion of the [c2]daisy chain unit. Ultraviolet irradiation caused the gels to bend towards the light source. The response of the [c2]AzoCD2 xerogel, even under dry conditions, is very fast (7° every second), which is 10,800 times faster than the [c2]AzoCD2 hydrogel (7° every 3 h). In addition, the [c2]AzoCD2 xerogel was used as a crane arm to lift an object using ultraviolet irradiation to produce mechanical work.
NASA Astrophysics Data System (ADS)
Çiçek, Adem; Kara, Fuat; Kıvak, Turgay; Ekici, Ergün; Uygur, İlyas
2015-11-01
In this study, a number of wear and tensile tests were performed to elucidate the effects of deep cryogenic treatment on the wear behavior and mechanical properties (hardness and tensile strength) of AISI H13 tool steel. In accordance with this purpose, three different heat treatments (conventional heat treatment (CHT), deep cryogenic treatment (DCT), and deep cryogenic treatment and tempering (DCTT)) were applied to tool steel samples. DCT and DCTT samples were held in nitrogen gas at -145 °C for 24 h. Wear tests were conducted on a dry pin-on-disk device using two loads of 60 and 80 N, two sliding velocities of 0.8 and 1 m/s, and a wear distance of 1000 m. All test results showed that DCT improved the adhesive wear resistance and mechanical properties of AISI H13 steel. The formation of small-sized and uniformly distributed carbide particles and the transformation of retained austenite to martensite played an important role in the improvements in the wear resistance and mechanical properties. After cleavage fracture, the surfaces of all samples were characterized by the cracking of primary carbides, while the DCT and DCTT samples displayed microvoid formation by decohesion of the fine carbides precipitated during the cryo-tempering process.
The Effect of Coatings on the Wear Behavior of Ti6Al4V Alloy Used in Biomedical Applications
NASA Astrophysics Data System (ADS)
Danışman, Ş.; Odabas, D.; Teber, M.
2018-01-01
The properties expected from implant materials are biocompatibility, long service life and wear resistance. The wear resistance of the implant materials varies according to the type of implant, usage area and the movement. The ability of implant material to be more compatible with biological tissues and to increase the useful life depends on the surface properties. Today many different kind of surface modification techniques are applying on medical and dental implant surfaces to improve surface specifications and wear resistance. In this study TiN, TiAlN, TiCN coatings were applied on Ti6Al4V alloy used as implant material by reactive magnetron sputtering method. The wear resistances of uncoated Ti6Al4V alloy and TiN, TiAlN, TiCN coatings were investigated at room temperature under dry conditions. The wear resistance at different load and different sliding rates were compared using an wear tester. The wear losses, wear track widths and friction coefficients of coated and uncoated Ti6Al4V alloys are taken into account for comparison. The results show that a significant improvement in wear resistance of the alloy with the coating is achieved and TiN-coated Ti6Al4V alloy has the highest wear resistance.
Visualization of Sliding and Deformation of Orbital Fat During Eye Rotation
Hötte, Gijsbert J.; Schaafsma, Peter J.; Botha, Charl P.; Wielopolski, Piotr A.; Simonsz, Huibert J.
2016-01-01
Purpose Little is known about the way orbital fat slides and/or deforms during eye movements. We compared two deformation algorithms from a sequence of MRI volumes to visualize this complex behavior. Methods Time-dependent deformation data were derived from motion-MRI volumes using Lucas and Kanade Optical Flow (LK3D) and nonrigid registration (B-splines) deformation algorithms. We compared how these two algorithms performed regarding sliding and deformation in three critical areas: the sclera-fat interface, how the optic nerve moves through the fat, and how the fat is squeezed out under the tendon of a relaxing rectus muscle. The efficacy was validated using identified tissue markers such as the lens and blood vessels in the fat. Results Fat immediately behind the eye followed eye rotation by approximately one-half. This was best visualized using the B-splines technique as it showed less ripping of tissue and less distortion. Orbital fat flowed around the optic nerve during eye rotation. In this case, LK3D provided better visualization as it allowed orbital fat tissue to split. The resolution was insufficient to visualize fat being squeezed out between tendon and sclera. Conclusion B-splines performs better in tracking structures such as the lens, while LK3D allows fat tissue to split as should happen as the optic nerve slides through the fat. Orbital fat follows eye rotation by one-half and flows around the optic nerve during eye rotation. Translational Relevance Visualizing orbital fat deformation and sliding offers the opportunity to accurately locate a region of cicatrization and permit an individualized surgical plan. PMID:27540495
Swarms of repeating stick-slip icequakes triggered by snow loading at Mount Rainier volcano
NASA Astrophysics Data System (ADS)
Allstadt, Kate; Malone, Stephen D.
2014-05-01
We have detected over 150,000 small (M < 1) low-frequency ( 1-5 Hz) repeating earthquakes over the past decade at Mount Rainier volcano, most of which were previously undetected. They are located high (>3000 m) on the glacier-covered edifice and occur primarily in weeklong to monthlong swarms composed of simultaneous distinct families of events. Each family contains up to thousands of earthquakes repeating at regular intervals as often as every few minutes. Mixed polarity first motions, a linear relationship between recurrence interval and event size, and strong correlation between swarm activity and snowfall suggest the source is stick-slip basal sliding of glaciers. The sudden added weight of snow during winter storms triggers a temporary change from smooth aseismic sliding to seismic stick-slip sliding in locations where basal conditions are favorable to frictional instability. Coda wave interferometry shows that source locations migrate over time at glacial speeds, starting out fast and slowing down over time, indicating a sudden increase in sliding velocity triggers the transition to stick-slip sliding. We propose a hypothesis that this increase is caused by the redistribution of basal fluids rather than direct loading because of a 1-2 day lag between snow loading and earthquake activity. This behavior is specific to winter months because it requires the inefficient drainage of a distributed subglacial drainage system. Identification of the source of these frequent signals offers a view of basal glacier processes, discriminates against alarming volcanic noises, documents short-term effects of weather on the cryosphere, and has implications for repeating earthquakes, in general.
Rubber contact mechanics: adhesion, friction and leakage of seals.
Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J
2017-12-13
We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.
Cyclic Behavior of Mortarless Brick Joints with Different Interlocking Shapes
Liu, Hongjun; Liu, Peng; Lin, Kun; Zhao, Sai
2016-01-01
The framed structure infilled with a mortarless brick (MB) panel exhibits considerable in-plane energy dissipation because of the relative sliding between bricks and good out-of-plane stability resulting from the use of interlocking mechanisms. The cyclic behaviors of MB are investigated experimentally in this study. Two different types of bricks, namely non-interlocking mortarless brick (N-IMB) and interlocking mortarless brick (IMB), are examined experimentally. The cyclic behavior of all of the joints (N-IMB and IMB) are investigated in consideration of the effects of interlocking shapes, loading compression stress levels and loading cycles. The hysteretic loops of N-IMB and IMB joints are obtained, according to which a mechanical model is developed. The Mohr–Coulomb failure criterion is employed to describe the shear failure modes of all of the investigated joints. A typical frictional behavior is observed for the N-IMB joints, and a significant stiffening effect is observed for the IMB joints during their sliding stage. The friction coefficients of all of the researched joints increase with the augmentation of the compression stress level and improvement of the smoothness of the interlocking surfaces. An increase in the loading cycle results in a decrease in the friction coefficients of all of the joints. The degradation rate (DR) of the friction coefficients increases with the reduction in the smoothness of the interlocking surface. PMID:28773291
Studying red blood cell agglutination by measuring membrane viscosity with optical tweezers
NASA Astrophysics Data System (ADS)
Fernandes, Heloise P.; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz C.; Barjas-Castro, Maria L.; Cesar, Carlos L.
2007-09-01
The red blood cell (RBC) viscoelastic membrane contains proteins and glycoproteins embedded in a fluid lipid bilayer that are responsible for cell agglutination. Manipulating RBCs rouleaux with a double optical tweezers, we observed that the cells slide easily one over the others but are strongly connected by their edges. An explanation for this behavior could be the fact that when the cells slide one over the others, proteins are dragged through the membrane. It confers to the movement a viscous characteristic that is dependent of the velocity between the RBCs and justifies why is so easy to slide them apart. Therefore, in a first step of this work, by measuring the force as a function of the relative velocity between two cells, we confirmed this assumption and used this viscous characteristic of the RBC rouleaux to determine the apparent membrane viscosity of the cell. As this behavior is related to the proteins interactions, we can use the apparent membrane viscosity to obtain a better understanding about cell agglutination. Methods related to cell agglutination induced by antigen-antibody interactions are the basis of most of tests used in transfusion centers. Then, in a second step of this work, we measured the apparent membrane viscosity using antibodies. We observed that this methodology is sensitive to different kinds of bindings between RBCs. Better comprehension of the forces and bindings between RBCs could improve the sensibility and specificity of the hemagglutination reactions and also guides the development of new potentiator substances.
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides.
Handwerger, Alexander L; Rempel, Alan W; Skarbek, Rob M; Roering, Joshua J; Hilley, George E
2016-09-13
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length [Formula: see text] that is shorter for higher effective stresses. However, landslides that are extensive enough to fall within this regime can nevertheless slide slowly for months or years before catastrophic failure. Our results suggest that the diversity of slip behavior observed during landslides can be described with a single model adapted from standard fault mechanics treatments.
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides
Handwerger, Alexander L.; Rempel, Alan W.; Skarbek, Rob M.; Roering, Joshua J.; Hilley, George E.
2016-01-01
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length h* that is shorter for higher effective stresses. However, landslides that are extensive enough to fall within this regime can nevertheless slide slowly for months or years before catastrophic failure. Our results suggest that the diversity of slip behavior observed during landslides can be described with a single model adapted from standard fault mechanics treatments. PMID:27573836
Bonhoeffer, Bastian; Kwade, Arno; Juhnke, Michael
2018-03-01
Flexible manufacturing technologies for solid oral dosage forms with a continuous adjustability of the manufactured dose strength are of interest for applications in personalized medicine. This study explored the feasibility of using microvalve technology for the manufacturing of different solid oral dosage form concepts. Hard gelatin capsules filled with excipients, placebo tablets, and polymer films, placed in hard gelatin capsules after drying, were considered as substrates. For each concept, a basic understanding of relevant formulation parameters and their impact on dissolution behavior has been established. Suitable matrix formers, present either on the substrate or directly in the drug nanosuspension, proved to be essential to prevent nanoparticle agglomeration of the drug nanoparticles and to ensure a fast dissolution behavior. Furthermore, convection and radiation drying methods were investigated for the fast drying of drug nanosuspensions dispensed onto polymer films, which were then placed in hard gelatin capsules. Changes in morphology and in drug and matrix former distribution were observed for increasing drying intensity. However, even fast drying times below 1 min could be realized, while maintaining the nanoparticulate drug structure and a good dissolution behavior. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Locke, Robin L.; Miller, Alison L.; Seifer, Ronald; Heinze, Justin E.
2015-01-01
This study examined contextually inappropriate (CI) anger in relation to emotion recognition and situation knowledge, negative social experiences, and externalizing behavior among low-income 4-year-olds attending Head Start (n = 134). Approximately 23% showed anger when presented with positive/neutral slides and videos (valence-incongruent CI…
What Is Beautiful Feels Good: Affective Reactions to Physical Attractiveness.
ERIC Educational Resources Information Center
Carducci, Bernardo J.; Ogan, Tamra A.
Previous research has consistently demonstrated that variations in physical attractiveness elicit different evaluative and behavioral responses. To assess differences in affective responses to variations in physical attractiveness and the affect of sex on those responses, 76 college students (31 male and 45 female) viewed colored slides of an…
ERIC Educational Resources Information Center
MacArthur, Brenda L.; Villagran, Melinda M.
2015-01-01
This study examines students' motives for communicating with their instructors when the instructor exhibits inappropriate or unprofessional online behavior. To understand the relationship between what we call instructors' digital expectancy violations and students' motives for communicating with instructors, students' levels of task, social, and…
Secondary Schools Curriculum Guide, Mathematics, Grades 10-12. Revised.
ERIC Educational Resources Information Center
Cranston School Dept., RI.
Behavioral objectives for grades 10 through 12 are specified for plane geometry, algebra, general mathematics, computer mathematics, slide rule mathematics, basic college mathematics, trigonometry, analytic geometry, calculus and probability. Most sections present material in terms of portions of a school year. At least one major objective is…
A developmental model of recreation choice behavior
Daniel R. Williams
1985-01-01
Recreation choices are viewed as including, at least implicitly, a selection of an activity, a setting, and a set of companions. With development these three elements become increasingly differentiated from one another. The model is tested by examining the perceived similarities among a set of 15 recreation choices depicted in color slides.
Drying kinetics of apricot halves in a microwave-hot air hybrid oven
NASA Astrophysics Data System (ADS)
Horuz, Erhan; Bozkurt, Hüseyin; Karataş, Haluk; Maskan, Medeni
2017-06-01
Drying behavior and kinetics of apricot halves were investigated in a microwave-hot air domestic hybrid oven at 120, 150 and 180 W microwave power and 50, 60 and 70 °C air temperature. Drying operation was finished when the moisture content reached to 25% (wet basis) from 77% (w.b). Increase in microwave power and air temperature increased drying rates and reduced drying time. Only falling rate period was observed in drying of apricot halves in hybrid oven. Eleven mathematical models were used for describing the drying kinetics of apricots. Modified logistic model gave the best fitting to the experimental data. The model has never been used to explain drying behavior of any kind of food materials up to now. Fick's second law was used for determination of both effective moisture diffusivity and thermal diffusivity values. Activation energy values of dried apricots were calculated from Arrhenius equation. Those that obtained from effective moisture diffusivity, thermal diffusivity and drying rate constant values ranged from 31.10 to 39.4 kJ/mol, 29.56 to 35.19 kJ/mol, and 26.02 to 32.36 kJ/mol, respectively.
Effect of suspension property on granule morphology and compaction behavior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hae-Weon Lee, Guesup Song, In-Sik Suk
1995-12-31
Granule morphology is an important factor during dry pressing, since it has great influences on die flowability, compaction ratio, and resulting green microstructure. Granule morphology and packing structure of ultrafine Si{sub 3}N{sub 4} particles in the granule were optimized during spray drying by adjusting the suspension structure. The particle packing structure of spray-dried granule was investigated with suspension structure. The effects of granule morphology and its particle packing structure on compaction and resultant sintering behavior were evaluated.
Scaled experiments to determine the role of density on granular flows behavior: preliminary results
NASA Astrophysics Data System (ADS)
Rodriguez Sedano, L. A.; Sarocchi, D.; Borselli, L.; Segura, O.
2013-12-01
Geological granular flows are very complex, gravity driven phenomena which can show different behaviors depending on its origin and the characteristics of the constituent material. Due to their dangerous nature, and multiple scientific and technological applications, these phenomena has being studied deeply in order to have a better comprehension, however, after more than one century of scientific research it remains as an open topic with more questions than answers. One of the aspects that still need exhaustive research is the effect of clast density on the flowing granular material, as pointed out by previous laboratory and field studies. There are anyway few studies which have tried to explain the role of bulk density, as well the density of different phases, as it increasing or decreasing on the kinematic and the rheological characteristics of geological granular flows. The content of low density juvenile material seems to condition the processes of transformations of debris flows to more diluted phases, as well the transport and emplacing mechanisms. It is well known that the content of clay in debris flows has great influence on its behavior, physical processes and the deposits characteristics for this reason lahars has being subdivided in base of this parameter. Our hypothesis is that, in like manner, the presence of low density material inside the granular flows (dry and wet) could conditioning its physical characteristics and its behavior. In order to put this to the test, we made some laboratory experiments using a five meter long and 0.3 m wide experimental flume equipped with a wide range of sensors and laser barriers to precisely measure the rheological properties and kinematic of the sliding avalanches. A special effort was devoted to determine a threshold or critical level in the amount of low density material at which the avalanche behavior suffer appreciable changes. The obtained preliminary results confirm our hypothesis and encouraged to perform further experiments. Such studies are important because they could provide useful information for developing analog models that take into account this important physical property.
Investigation of multi-scale flash-weakening of rock surfaces during high speed slip
NASA Astrophysics Data System (ADS)
Barbery, M. R.; Saber, O.; Chester, F. M.; Chester, J. S.
2017-12-01
A significant reduction in the coefficient of friction of rock can occur if sliding velocity approaches seismic rates as a consequence of weakening of microscopic sliding contacts by flash heating. Using a high-acceleration and -speed biaxial apparatus equipped with a high-speed Infra-Red (IR) camera to capture thermographs of the sliding surface, we have documented the heterogeneous distribution of temperature on flash-heated decimetric surfaces characterized by linear arrays of high-temperature, mm-size spots, and streaks. Numerical models that are informed by the character of flash heated surfaces and that consider the coupling of changes in temperature and changes in the friction of contacts, supports the hypothesis that independent mechanisms of flash weakening operate at different contact scales. Here, we report on new experiments that provide additional constraints on the life-times and rest-times of populations of millimeter-scale contacts. Rock friction experiments conducted on Westerly granite samples in a double-direct shear configuration achieve velocity steps from 1 mm/s to 900 mm/s at 100g accelerations over 2 mm of displacement with normal stresses of 22-36 MPa and 30 mm of displacement during sustained high-speed sliding. Sliding surfaces are machined to roughness similar to natural fault surfaces and that allow us to control the characteristics of millimeter-scale contact populations. Thermographs of the sliding surface show temperatures up to 200 C on millimeter-scale contacts, in agreement with 1-D heat conduction model estimates of 180 C. Preliminary comparison of thermal modeling results and experiment observations demonstrate that we can distinguish the different life-times and rest-times of contacts in thermographs and the corresponding frictional weakening behaviors. Continued work on machined surfaces that lead to different contact population characteristics will be used to test the multi-scale and multi-mechanism hypothesis for flash weakening during seismic slip on rough fault surfaces.
Explosion Amplitude Reduction due to Fractures in Water-Saturated and Dry Granite
NASA Astrophysics Data System (ADS)
Stroujkova, A. F.; Leidig, M.; Bonner, J. L.
2013-12-01
Empirical observations made at the Semipalatinsk Test Site suggest that nuclear tests in the fracture zones left by previous explosions ('repeat shots') show reduced seismic amplitudes compared to the nuclear tests in virgin rocks. Likely mechanisms for the amplitude reduction in the repeat shots include increased porosity and reduced strength and elastic moduli, leading to pore closing and frictional sliding. Presence of pore water significantly decreases rock compressibility and strength, thus affecting seismic amplitudes. A series of explosion experiments were conducted in order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fracture zones of previously detonated explosions. Explosions in water-saturated granite were conducted in central New Hampshire in 2011 and 2012. Additional explosions in dry granite were detonated in Barre, VT in 2013. The amplitude reduction is different between dry and water-saturated crystalline rocks. Significant reduction in seismic amplitudes (by a factor of 2-3) in water-saturated rocks was achieved only when the repeat shot was detonated in the extensive damage zone created by a significantly larger (by a factor of 5) explosion. In case where the first and the second explosions were similar in yield, the amplitude reduction was relatively modest (5-20%). In dry rocks the amplitude reduction reached a factor of 2 even in less extensive damage zones. In addition there are differences in frequency dependence of the spectral amplitude ratios between explosions in dry and water-saturated rocks. Thus the amplitude reduction is sensitive to the extent of the damage zone as well as the pore water content.
Walks of bubbles on a hot wire in a liquid bath
NASA Astrophysics Data System (ADS)
Duchesne, A.; Caps, H.
2017-05-01
When a horizontal resistive wire is heated up to the boiling point in a subcooled liquid bath, some vapor bubbles nucleate on its surface. The traditional nucleate boiling theory predicts that bubbles generated from active nucleate sites grow up and depart from the heating surface due to buoyancy and inertia. However, we observed here a different behavior: the bubbles slide along the heated wire. In this situation, unexpected regimes are observed; from the simple sliding motion to bubble clustering. We noticed that bubbles could rapidly change their moving direction and may also interact. Finally, we propose an interpretation for both the attraction between the bubbles and the wire and for the motion of the bubbles on the wire in terms of Marangoni effects.
Friction and wear of single-crystal manganese-zinc ferrite
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Buckley, D. H.
1979-01-01
Sliding friction experiments were conducted with single crystal manganese-zinc ferrite in contact with itself and with transition metals. Results indicate mating highest atomic density directions (110) on matched crystallographic planes exhibit the lowest coefficient of friction, indicating that direction is important in the friction behavior of ferrite. Matched parallel high atomic density planes and crystallographic directions at the interface exhibit low coefficients of friction. The coefficients of friction for ferrite in contact with various metals are related to the relative chemical activity of these metals. The more active the metal, the higher the coefficient of friction. Cracking and the formation of hexagon- and rectangular-shaped platelet wear debris due to cleavages of (110) planes are observed on the ferrite surfaces as a result of sliding.
Creep Behavior of Near-Stoichiometric Polycrystalline Binary NiAl
NASA Technical Reports Server (NTRS)
Raj, S. V.
2002-01-01
New and published constant load creep and constant engineering strain rate data on near-stoichiometric binary NiAl in the intermediate temperature range 700 to 1300 K are reviewed. Both normal and inverse primary creep curves are observed depending on stress and temperature. Other characteristics relating to creep of NiAl involving grain size, stress and temperature dependence are critically examined and discussed. At stresses below 25 MPa and temperatures above 1000 K, a new grain boundary sliding mechanism was observed with n approx. 2, Qc approx. 100 kJ/ mol and a grain size exponent of about 2. It is demonstrated that Coble creep and accommodated grain boundary sliding models fail to predict the experimental creep rates by several orders of magnitude.
Friction and transfer behavior of pyrolytic boron nitride in contact with various metals
NASA Technical Reports Server (NTRS)
Buckley, D. H.
1976-01-01
Sliding friction experiments were conducted with pyrolytic boron nitride in sliding contact with itself and various metals. Auger emission spectroscopy was used to monitor transfer of pyrolytic boron nitride to metals and metals to pyrolytic boron nitride. Results indicate that the friction coefficient for pyrolytic boron nitride in contact with metals can be related to the chemical activity of the metals and more particularly to the d valence bond character of the metal. Transfer was found to occur to all metals except silver and gold and the amount of transfer was less in the presence than in the absence of metal oxide. Friction was less for pyrolytic boron nitride in contact with a metal in air than in vacuum.
Dynamics of solid lubrication as observed by optical microscopy
NASA Technical Reports Server (NTRS)
Sliney, H. E.
1976-01-01
A bench metallograph was converted into a micro contact imager by the addition of a tribometer employing a steel ball in sliding contact with a glass disk. The sliding contact was viewed in real time by means of projection microscope optics. The dynamics of abrasive particles and of solid lubricant particles within the contact were observed in detail. The contact was characterized by a constantly changing pattern of elastic strain with the passage of surface discontinuities and solid particles. Abrasive particles fragmented upon entering the contact, embedded in one surface and scratched the other; in contrast, the solid lubricant particles flowed plastically into thin films. The rheological behavior of the lubricating solids gave every appearance of a paste-like consistency within the Hertzian contact.
NASA Astrophysics Data System (ADS)
Wu, Yun-jie; Li, Guo-fei
2018-01-01
Based on sliding mode extended state observer (SMESO) technique, an adaptive disturbance compensation finite control set optimal control (FCS-OC) strategy is proposed for permanent magnet synchronous motor (PMSM) system driven by voltage source inverter (VSI). So as to improve robustness of finite control set optimal control strategy, a SMESO is proposed to estimate the output-effect disturbance. The estimated value is fed back to finite control set optimal controller for implementing disturbance compensation. It is indicated through theoretical analysis that the designed SMESO could converge in finite time. The simulation results illustrate that the proposed adaptive disturbance compensation FCS-OC possesses better dynamical response behavior in the presence of disturbance.
Wear resistance of hydrophobic surfaces
NASA Astrophysics Data System (ADS)
Martinez, MA; Abenojar, J.; Pantoja, M.; López de Armentia, S.
2017-05-01
Nature has been an inspiration source to develop artificial hydrophobic surfaces. During the latest years the development of hydrophobic surfaces has been widely researched due to their numerous ranges of industrial applications. Industrially the use of hydrophobic surfaces is being highly demanded. This is why many companies develop hydrophobic products to repel water, in order to be used as coatings. Moreover, these coating should have the appropriated mechanical properties and wear resistance. In this work wear study of a hydrophobic coating on glass is carried out. Hydrophobic product used was Sika Crystal Dry by Sika S.A.U. (Alcobendas, Spain). This product is currently used on car windshield. To calculate wear resistance, pin-on-disk tests were carried out in dry and water conditions. The test parameters were rate, load and sliding distance, which were fixed to 60 rpm, 5 N and 1000 m respectively. A chamois was used as pin. It allows to simulate a real use. The friction coefficient and loss weight were compared to determinate coating resistance
The effect of friction in coulombian damper
NASA Astrophysics Data System (ADS)
Wahad, H. S.; Tudor, A.; Vlase, M.; Cerbu, N.; Subhi, K. A.
2017-02-01
The study aimed to analyze the damping phenomenon in a system with variable friction, Stribeck type. Shock absorbers with limit and dry friction, is called coulombian shock-absorbers. The physical damping vibration phenomenon, in equipment, is based on friction between the cushioning gasket and the output regulator of the shock-absorber. Friction between them can be dry, limit, mixture or fluid. The friction is depending on the contact pressure and lubricant presence. It is defined dimensionless form for the Striebeck curve (µ friction coefficient - sliding speed v). The friction may damp a vibratory movement or can maintain it (self-vibration), depending on the µ with v (it can increase / decrease or it can be relative constant). The solutions of differential equation of movement are obtained for some work condition of one damper for automatic washing machine. The friction force can transfer partial or total energy or generates excitation energy in damper. The damping efficiency is defined and is determined analytical for the constant friction coefficient and for the parabolic friction coefficient.
NASA Technical Reports Server (NTRS)
Foster, T. L.
1974-01-01
The effect of storage of dry heat treated Teflon ribbons under nitrogen gas followed by high vacuum on the recovery of hardy organisms from the ribbons was studied. A similar experiment was performed on spore crops of hardy organisms recovered previously from Cape Canaveral. Hardy organisms have been inoculated onto slides and subjected to an artificial Martian environment in an attempt to demonstrate their growth in this environment. Additional experiments using the artificial Martian environment include response of soil samples from the VAB with both constant temperature and freeze-thaw cycles. These experiments were performed with dried soil and soil containing added water. Other investigations included the effect of heatshock on soil samples, psychrophilic counts of new soil samples from the manufacture area of the Viking spacecraft, effect of pour plate versus spread plate on psychrophilic counts, and preparation of spore crops of hardy organisms from Cape Canaveral.
2016-09-13
through the deformed β matrix . A total elongation of 1000% and strain-rate-sensitivity exponent m = 0.48 were obtained at 550 °C and 2 × 10−4 s−1...two orders of magnitude faster than the corresponding static behaviors due to enhanced diffusion through the deformed b matrix . A total elongation of...various metallic materials, including titanium alloys, is usually the result of concurrent grain- or interphase-boundary sliding, grain- matrix
NASA Astrophysics Data System (ADS)
Singh, Harpal
This dissertation is divided into two categories based upon lubrication functionality and its application. The categories are: Dry film lubrication and Fluid film lubrication with thin film coatings. Thin film coatings examined in this work were deposited using closed field unbalanced magnetron sputtering and RF-DC coupled magnetron sputtering systems. In Dry/Solid film lubrication, the mechanical, structural and tribological properties of two Molybdenum disulphide (MoS2) based coatings are examined and evaluated. Among the two coatings, one coating is doped with Ti (Ti-MoS2) and the other is a combination of metal, lubricant and oxide (Sb2O3/Au - MoS2). These coatings are known to provide low friction in vacuum environments. The goal of this work was to evaluate friction and wear performance of MoS2 doped coatings in unidirectional and reciprocating sliding contact under different environmental conditions. Sliding contact results showed friction and wear dependence on temperature and humidity. The formation and removal of transfer films and the recrystallization and reorientation of basal layers on the steel counterface was observed as the mechanism for low friction. Structural analysis revealed a relationship between the microstructural properties and tribological performance. It was also observed that the addition of dopants (Ti, Au, Sb 2O3) improved the mechanical properties as compared to pure MoS2 coatings. Further, the rolling contact performance of the coatings was measured on a five ball on rod tribometer and a Thrust bearing tribometer under vacuum and air environments. The rolling contact experiments indicated that life of the rolling components depend on the amount of material present between the contacts. Fluid film lubrication with thin film coatings investigates the possibilities to improve the performance and durability of tribological components when oils and thin films are synergistically coupled. In this work, the ability of a Diamond Like Carbon coating to increase the durability of contacting surfaces under boundary lubrication were studied. The performance of highly hydrogenated Diamond Like Carbon (DLC) was evaluated in a mixed sliding and rolling contact. Experimental results show significant improvement in fatigue life of steel specimens after coating with a highly hydrogenated Diamond Like Carbon coating. The improved fatigue life is attributed to the coating microstructure and the mechanical properties.
The friction and wear of TPS fibers
NASA Technical Reports Server (NTRS)
Bascom, W. D.; Wong, S.
1987-01-01
The sliding friction behavior of single filaments of SiO2, SiC, and an aluminoborosilicate has been determined. These fibers are used in thermal protection systems (TPS) and are subject to damage during weaving and aero-maneuvering. All fibers exhibited stick-slip friction indicating the successive formation and rupture of strong junctions between the contacting filaments. The static frictional resistance of the sized SiC filament was 4X greater than for the same filament after heat cleaning. This result suggests that the sizing is an organic polymer with a high shear yield strength. Heat cleaning exposes the SiC surface and/or leaves an inorganic residue so that the adhesional contact between filaments has a low fracture energy and frictional sliding occurs by brittle fracture. The frictional resistances of the sized and heat cleaned SiO2 and glass filaments were all comparable to that of the heat cleaned SiC. It would appear that the sizings as well as the heat cleaned surfaces of the silica and glass have low fracture energies so that the sliding resistance is determined by brittle fracture.
NASA Astrophysics Data System (ADS)
Casalbore, D.; Bosman, A.; Casas, D.; Chiocci, F. L.; Martorelli, E.; Ridente, D.
2017-12-01
The recent collection of multibeam bathymetry and single-channel seismic profiles on the Calabro-Tyrrhenian continental margin in Southern Italy allowed us to depict a large suite of mass-wasting processes, ranging from gullies up to shelf-indenting canyon system along with over 400 landslide scars, affecting the 52% of the entire area. In detail, slide scars occur from the coast down to -1700 m, with mobilized volumes ranging from some hundreds of m3 up to tens of millions of m3. On the whole, they affect an area of >85 km2, being able to mobilize approximately 1.4 km3. These slides also show a large variability of features both in the headwall, translational and toe domain, thus providing useful insights for a better understanding of their failure and post-failure behavior. The aim of this study is to show the magnitude-frequency relationship of this large amount of slides in order to quantify a range of probabilities for the occurrence of new landslide events as well as to illustrate the main mechanisms that control their development and emplacement.
Tribo-electrochemical characterization of metallic biomaterials for total joint replacement.
Diomidis, N; Mischler, S; More, N S; Roy, Manish
2012-02-01
Knee and hip joint replacement implants involve a sliding contact between the femoral component and the tibial or acetabular component immersed in body fluids, thus making the metallic parts susceptible to tribocorrosion. Micro-motions occur at points of fixation leading to debris and ion release by fretting corrosion. β-Titanium alloys are potential biomaterials for joint prostheses due to their biocompatibility and compatibility with the mechanical properties of bone. The biotribocorrosion behavior of Ti-29Nb-13Ta-4.6Zr was studied in Hank's balanced salt solution at open circuit potential and at an applied potential in the passive region. Reciprocating sliding tribocorrosion tests were carried out against technical grade ultra high molecular weight polyethylene, while fretting corrosion tests were carried out against alumina. The wear of the alloy is insignificant when sliding against polyethylene. However, depassivation does take place, but the tested alloy showed an ability to recover its passive state during sliding. The abrasivity of the alloy depends on the electrochemical conditions of the contact, while the wear of polyethylene proceeds through third body formation and material transfer. Under fretting corrosion conditions recovery of the passive state was also achieved. In a fretting contact wear of the alloy proceeds through plastic deformation of the bulk material and wear resistance depends on the electrochemical conditions. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Phase diagram for inertial granular flows.
DeGiuli, E; McElwaine, J N; Wyart, M
2016-07-01
Flows of hard granular materials depend strongly on the interparticle friction coefficient μ_{p} and on the inertial number I, which characterizes proximity to the jamming transition where flow stops. Guided by numerical simulations, we derive the phase diagram of dense inertial flow of spherical particles, finding three regimes for 10^{-4}≲I≲10^{-1}: frictionless, frictional sliding, and rolling. These are distinguished by the dominant means of energy dissipation, changing from collisional to sliding friction, and back to collisional, as μ_{p} increases from zero at constant I. The three regimes differ in their kinetics and rheology; in particular, the velocity fluctuations and the stress ratio both display nonmonotonic behavior with μ_{p}, corresponding to transitions between the three regimes of flow. We rationalize the phase boundaries between these regimes, show that energy balance yields scaling relations between microscopic properties in each of them, and derive the strain scale at which particles lose memory of their velocity. For the frictional sliding regime most relevant experimentally, we find for I≥10^{-2.5} that the growth of the macroscopic friction μ(I) with I is induced by an increase of collisional dissipation. This implies in that range that μ(I)-μ(0)∼I^{1-2b}, where b≈0.2 is an exponent that characterizes both the dimensionless velocity fluctuations L∼I^{-b} and the density of sliding contacts χ∼I^{b}.
Friction of sodium alginate hydrogel scaffold fabricated by 3-D printing.
Yang, Qian; Li, Jian; Xu, Heng; Long, Shijun; Li, Xuefeng
2017-04-01
A rapid prototyping technology, formed by three-dimensional (3-D) printing and then crosslinked by spraying Ca 2+ solution, is developed to fabricate a sodium alginate (SA) hydrogel scaffold. The porosity, swelling ratio, and compression modulus of the scaffold are investigated. A friction mechanism is developed by studying the reproducible friction behavior. Our results show that the scaffold can have 3-D structure with a porosity of 52%. The degree of swelling of the SA hydrogel scaffold is 8.5, which is nearly the same as bulk SA hydrogel. SA hydrogel exhibits better compressive resilience than bulk hydrogel despite its lower compressive modulus compared to bulk hydrogel. The SA hydrogel scaffold exhibits a higher frictional force at low sliding velocity (10 -6 to 10 -3 m/s) compared to bulk SA hydrogel, and they are equal at high sliding velocity (10 -2 to 1 m/s). For a small pressure (0.3 kPa), the SA hydrogel scaffold shows good friction reproducibility. In contrast, bulk SA hydrogel shows poor reproducibility with respect to friction behavior. The differences in friction behaviors between the SA hydrogel scaffold and bulk SA hydrogel are related to the structure of the scaffold, which can keep a stable hydrated lubrication layer.
Lee, Wonmok; Kim, Seulgi; Kim, Seulki; Kim, Jin-Ho; Lee, Hyunjung
2015-02-15
There are active researches on well ordered opal films due to their possible applications to various photonic devices. A recently developed slide coating method is capable of rapid fabrication of large area opal films from aqueous colloidal dispersion. In the current study, the slide coating of polystyrene colloidal dispersions in water/i-propanol (IPA) binary media is investigated. Under high IPA content in a dispersing medium, resulting opal film showed a deterioration of long range order, as well as a decreased film thickness due to dilution effect. From the binary liquid, the dried opal films exhibited the unprecedented topological groove patterns with varying periodic distances as a function of alcohol contents in the media. The groove patterns were consisted of the hierarchical structures of the terraced opal layers with periodic thickness variations. The origin of the groove patterns was attributed to a shear-induced periodic instability of colloidal concentration within a thin channel during the coating process which was directly converted to a groove patterns in a resulting opal film due to rapid evaporation of liquid. The groove periods of opal films were in the range of 50-500 μm, and the thickness differences between peak and valley of the groove were significantly large enough to be optically distinguishable, such that the coated films can be utilized as the optical grating film to disperse infra-red light. Utilizing a lowered hydrophilicity of water/IPA dispersant, an opal film could be successfully coated on a flexible Mylar film without significant dewetting problem. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Guanchen; Shi, Xiaoliang; Huang, Yuchun; Liu, Xiyao; Yang, Meijun
2018-05-01
This paper investigates the effects of friction layer characteristics of Ni3Al matrix self-lubricating composites (NMCs) on the tribological properties sliding against ceramic ball Si3N4 at dry friction process at the different load conditions. The characteristics of friction layer are performed in terms of hardness of wear scars, thickness and elemental distributions of friction layer. The results show that the microhardness of wear scars of NMCs increases with the increase of the sliding time and applied load, which results in friction coefficient reduced and wear rate decreased, indicating that the tribological performance of NMCs is obviously affected by microhardness of wear scar. However, under excessive applied load, the performance of friction layer of NMCs is deteriorated for the spalling of wear debris and deformation of contact surface. Therefore, selecting appropriate load conditions during the sliding contact, at the transition to the optimal properties of friction layer maybe occur. NMCs exhibits excellent tribological properties at 15N, which leads to the lowest friction coefficient (0.386) and wear rate (2.48 × 10‑5 mm3 N‑1 m‑1), as well as the smoothest surface of wear track compared with the other load conditions. Meanwhile, the elemental distributions analysis of cross-section of friction layer of NMCs shows that the frictional structures can be divided into three main layers. The thickness of the friction-affected layer varies with the changing of applied load. These results could provide a reference for preparing the solid-lubrication materials with better tribological properties.
Effect of a two-year fluoride decay protection protocol on titanium brackets.
Khoury, Elie S; Abboud, Maher; Bassil-Nassif, Nayla; Bouserhal, Joseph
2011-12-01
Fluoride ion can attack titanium, causing its corrosion. Orthodontic patients being high-risk caries developers and in need of fluoride protection, the Center for Disease Control has developed a Fluoride Decay Prevention (FDP) protocol, consisting of a 6-minute tooth-brushing, followed by a 1-minute daily mouthwash, in addition to an in-clinic trimestrial topical fluoride gel application. This study aimed at evaluating gravimetrically, by scanning electron microscopy (SEM), and by sliding mechanics analysis, the consequences of FDP at 6, 12, 18, and 24months on titanium brackets corrosion. One hundred and fifty titanium brackets were randomly divided into five groups of 30. Group 1 was the control group. Groups 2, 3, 4, and 5 each received an equivalent of 6, 12, 18, and 24months of FDP treatment respectively. All groups were placed in artificial saliva for 2months and then rinsed. Subsequently, the brackets were dried, for 48hours, using Silica gel in a desiccator maintained at 37°C before testing. SEM analysis showed that numbers and dimensions of pits gradually increased due to corrosion as we moved from group 1 to group 5. Gravimetrical and sliding mechanics results revealed no statistical difference between groups 2 and 3, and a significant difference between groups 4 and 5 upon comparison with the control group. Surface changes due to corrosion were detected at 6 and 12months of FDP but had no clinical effects. However, the increase in sliding resistance and bracket weight loss became significant at 18 and 24months of FDP. Copyright © 2011 CEO. Published by Elsevier Masson SAS. All rights reserved.
Frictional behavior of carbonate-rich sediments in subduction zones
NASA Astrophysics Data System (ADS)
Rabinowitz, H. S.; Savage, H. M.; Carpenter, B. M.; Collettini, C.
2015-12-01
Carbonate-rich layers make up a significant component of subducting sediments around the world and may impact the frictional behavior of subduction zones. In order to investigate the effect of carbonate subduction, we conducted biaxial deformation experiments within a pressure vessel using the Brittle Rock deformAtion Versatile Apparatus (BRAVA) at INGV. We obtained input sediments for two subduction zones, the Hikurangi trench, New Zealand (ODP Site 1124) and the Peru trench (DSDP Site 321), which have carbonate/clay contents of ~40/60 wt% and ~80/20 wt%, respectively. Samples were saturated with distilled water mixed with 35g/l sea salt and deformed at room temperature. Experiments were conducted at σN = 1-50 MPa with sliding velocities of 1-300 μm/s and hold times of 1-1000 s. Frictional strength of Hikurangi gouge is 0.35-0.55 and Peru gouge is 0.55-0.65. Velocity-stepping tests show that the Hikurangi gouge is consistently velocity strengthening (friction rate parameter (a-b) > 0). The Peru gouge is mostly velocity strengthening but exhibits a minimum in a-b at the 3-10 μm/s velocity step (with velocity weakening behavior at 25 MPa, indicating the potential for earthquake nucleation). Slide-hold-slide tests show that the healing rate (β) of the Hikurangi gouge is 1x10-4-1x10-3 /decade which is comparable to that of clays (β~0.002 /decade) while the healing rate of Peru gouge (β~6x10-3-7x10-3 /decade) is closer to that of carbonate gouge (β~0.01 /decade). The mechanical results are complemented by microstructural analysis. In lower stress experiments, there is no obvious shear localization. At 25 and 50 MPa, pervasive boundary-parallel shears become dominant, particularly in the Peru samples. Degree of microstructural localization appears to correspond with the trends observed in velocity-dependence. Our preliminary results indicate that carbonate/clay compositions could have a significant impact on the frictional behavior of subducting sediments.
ERIC Educational Resources Information Center
Anderson, Elaine J.; And Others
Investigated was the effect of systematically combined high and low level cognitive objectives upon the acquisition of science learning. An instructional unit based on a Biological Sciences Curriculum Study (BSCS) Inquiry Slide Set (structure and function, control of blood sugar, a homeostatic mechanism) was chosen because it included stimuli for…
Characteristics of Transverse and Longitudinal Waves.
ERIC Educational Resources Information Center
Reister, W. A.
This monograph presents an autoinstructional program in the physical sciences. It is considered useful at the higher, middle and lower high school levels. Three behavioral objectives are listed and a time allotment of 35-40 minutes is suggested. A bibliography is included. A script, incorporating the use of a cassette player and slides, is used by…
Integrating Community with Collections in Educational Digital Libraries
ERIC Educational Resources Information Center
Akbar, Monika
2013-01-01
Some classes of Internet users have specific information needs and specialized information-seeking behaviors. For example, educators who are designing a course might create a syllabus, recommend books, create lecture slides, and use tools as lecture aid. All of these resources are available online, but are scattered across a large number of…
Nanoindentation of the surface layer of Hadfield's steel after sliding friction
NASA Astrophysics Data System (ADS)
Kolubaev, A. V.; Kolubaev, E. A.; Sizova, O. V.
2007-12-01
We have measured the nanohardness of a deformed near-surface layer of Hadfield’s steel upon friction testing. The phenomenon of shape recovery upon indentation has been observed, which is retained for several days after tribological tests. It s suggested that the strained material exhibits behavior analogous to nonlinear elasticity.
Learning to Estimate Slide Comprehension in Classrooms with Support Vector Machines
ERIC Educational Resources Information Center
Pattanasri, N.; Mukunoki, M.; Minoh, M.
2012-01-01
Comprehension assessment is an essential tool in classroom learning. However, the judgment often relies on experience of an instructor who makes observation of students' behavior during the lessons. We argue that students should report their own comprehension explicitly in a classroom. With students' comprehension made available at the slide…
Clay-clast aggregates: A new textural evidence for seismic fault sliding?
NASA Astrophysics Data System (ADS)
Boutareaud, Sébastien; Calugaru, Dan-Gabriel; Han, Raehee; Fabbri, Olivier; Mizoguchi, Kazuo; Tsutsumi, Akito; Shimamoto, Toshihiko
2008-03-01
To determine the processes responsible for slip-weakening in clayey gouge zones, rotary-shear experiments were conducted at seismic slip rates (equivalent to 0.9 and 1.3 m/s) at 0.6 MPa normal stress on a natural clayey gouge for saturated and non-saturated initial conditions. The mechanical behavior of the simulated faults shows a reproducible slip-weakening behavior, whatever initial moisture conditions. Examination of gouge obtained at the residual friction stage in saturated and non-saturated initial conditions allows the definition of two types of microstructures: a foliated type reflecting strain localization, and a non-foliated type composed of spherical aggregates. Friction experiments demonstrate that liquid-vapor transition of water within gouge due to frictional heating has a high capacity to explain the formation of spherical aggregates in the first meters of displacement. This result suggests that the occurrence of spherical aggregates in natural clayey fault gouges can constitute a new textural evidence for shallow depth pore water phase transition at seismic slip velocity and consequently for past seismic fault sliding.
Unconventional Behavior of Friction at the Nanoscale beyond Amontons' Law.
Chen, Jingrun; Gao, Wang
2017-08-05
By means of a many-body van der Waals (vdW)-corrected density functional theory approach, the atomic-scale friction of a prototypical tip-substrate system consisting of an Si tip and a graphene substrate is studied. In a loading-sliding process, the tip-substrate distance is found to be essential for nanofrictional behavior, through determining the competition between vdW contributions and electronic contributions. As the tip approaches the substrate, this competition results in a smooth transition of normal forces from attraction to repulsion, and the friction coefficient in turn undergoes a sign change from negative to positive with possible giant magnitude and strong anisotropy. The loading-sliding process does not introduce any chemical modification of the underlying system. These findings reveal the boundary of validity of Amontons' law, unify negative and giant friction coefficients, rationalize the experimentally observed anisotropy of nanofriction, and are universal when vdW interactions are crucial, all of which are helpful to establish a comprehensive picture of nanofriction. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Numerical investigation of sliding drops on an inclined surface
NASA Astrophysics Data System (ADS)
Legendre, Dominique; Pedrono, Annaig; Interface Group Team
2017-11-01
Despite it apparent simplicity, the behavior of a drop on an inclined solid surface is far to be properly reproduced by numerical simulation. It involves static, hysteresis and dynamic contact line behaviors. Depending on the fluid properties, the hysteresis and the wall inclination, different drop shapes (rounded, corner or pearling drop) can be observed. The 3D numerical simulations of sliding droplets presented in this work are based on a Volume of Fluid (VoF) solver without any interface reconstruction developed in the JADIM code. The surface tension is solved using the classical CSF (Continuum Surface Force) model and a sub grid model is used to describe under hysteresis conditions both the shape, the dissipation of the non resolved scales of a moving contact line. Numerical simulations are compared with the experiments of. The agreement with experiments is found to be very good for both he critical angle of inclination for siding as well as for the specific shapes: rounded, corner and pearling drops. The simulations have been used to extend the range of hysteresis covered by the experiments.
Walkowski, Slawomir; Lundin, Mikael; Szymas, Janusz; Lundin, Johan
2015-01-01
The way of viewing whole slide images (WSI) can be tracked and analyzed. In particular, it can be useful to learn how medical students view WSIs during exams and how their viewing behavior is correlated with correctness of the answers they give. We used software-based view path tracking method that enabled gathering data about viewing behavior of multiple simultaneous WSI users. This approach was implemented and applied during two practical exams in oral pathology in 2012 (88 students) and 2013 (91 students), which were based on questions with attached WSIs. Gathered data were visualized and analyzed in multiple ways. As a part of extended analysis, we tried to use machine learning approaches to predict correctness of students' answers based on how they viewed WSIs. We compared the results of analyses for years 2012 and 2013 - done for a single question, for student groups, and for a set of questions. The overall patterns were generally consistent across these 3 years. Moreover, viewing behavior data appeared to have certain potential for predicting answers' correctness and some outcomes of machine learning approaches were in the right direction. However, general prediction results were not satisfactory in terms of precision and recall. Our work confirmed that the view path tracking method is useful for discovering viewing behavior of students analyzing WSIs. It provided multiple useful insights in this area, and general results of our analyses were consistent across two exams. On the other hand, predicting answers' correctness appeared to be a difficult task - students' answers seem to be often unpredictable.
Fernando, Sumadhya D; Ihalamulla, Ratnasiri L; Wickremasinghe, Renu; de Silva, Nipun L; Thilakarathne, Janani H; Wijeyaratne, Pandu; Premaratne, Risintha G
2014-03-15
Individuals with fever are screened for malaria in specially-established malaria diagnostic laboratories set up in rural hospitals in the Northern and Eastern Provinces of Sri Lanka. Large numbers of blood smears negative for malaria parasites are being screened daily. Good quality smears are essential to maintain a high diagnostic competency among the technical staff. The modifications made to the World Health Organization (WHO) standard operating procedures to improve the quality of smears have been studied. A blinded, controlled, interventional study was conducted in 22 intervention and 21 control malaria diagnostic laboratories. Changes were made to the WHO standard operating procedure protocols to prepare, stain and examine blood smears for malaria parasite detection which were implemented in intervention laboratories. These included wipe-cleaning slides, preparing both thick and thin smears on the same slide, reversing the order of collecting blood for thick and thin smears, dry fixing thick smear for 20-25 minutes under table lamp, polishing the edge of spreader slide with sand paper and fixing the thin smear with methanol if not stained within four hours. Parameters with respect to quality of the smear as per WHO criteria were studied using randomly selected slides, and time taken for the report to be issued was recorded in both groups before and after the intervention. There were no significant differences observed in the parameters studied at baseline between the two groups or pre and post intervention in the control group. In the intervention group streak formation in thin smears was reduced from 29.4% to 5.0%. The average fixing time of thick smears was reduced from 2.4 hours to 20 minutes. Inappropriate thickness of thick smears reduced from 18.3% to 1.5%. Overall quality of thick smears and thin smears increased from 76.1% to 98.0% and 81.7% to 87.0%, respectively. The quality of slides bearing both thick and thin smears increased from 60.0% to 87.0%. New protocols with amendments to the WHO standard technical procedures ensure that good quality blood smears are prepared rapidly to diagnose malaria and the time required to issue the reports was reduced.
Steady and transient sliding under rate-and-state friction
NASA Astrophysics Data System (ADS)
Putelat, Thibaut; Dawes, Jonathan H. P.
2015-05-01
The physics of dry friction is often modelled by assuming that static and kinetic frictional forces can be represented by a pair of coefficients usually referred to as μs and μk, respectively. In this paper we re-examine this discontinuous dichotomy and relate it quantitatively to the more general, and smooth, framework of rate-and-state friction. This is important because it enables us to link the ideas behind the widely used static and dynamic coefficients to the more complex concepts that lie behind the rate-and-state framework. Further, we introduce a generic framework for rate-and-state friction that unifies different approaches found in the literature. We consider specific dynamical models for the motion of a rigid block sliding on an inclined surface. In the Coulomb model with constant dynamic friction coefficient, sliding at constant velocity is not possible. In the rate-and-state formalism steady sliding states exist, and analysing their existence and stability enables us to show that the static friction coefficient μs should be interpreted as the local maximum at very small slip rates of the steady state rate-and-state friction law. Next, we revisit the often-cited experiments of Rabinowicz (J. Appl. Phys., 22:1373-1379, 1951). Rabinowicz further developed the idea of static and kinetic friction by proposing that the friction coefficient maintains its higher and static value μs over a persistence length before dropping to the value μk. We show that there is a natural identification of the persistence length with the distance that the block slips as measured along the stable manifold of the saddle point equilibrium in the phase space of the rate-and-state dynamics. This enables us explicitly to define μs in terms of the rate-and-state variables and hence link Rabinowicz's ideas to rate-and-state friction laws. This stable manifold naturally separates two basins of attraction in the phase space: initial conditions in the first one lead to the block eventually stopping, while in the second basin of attraction the sliding motion continues indefinitely. We show that a second definition of μs is possible, compatible with the first one, as the weighted average of the rate-and-state friction coefficient over the time the block is in motion.
Moore, Diane E.; Byerlee, J.
1992-01-01
Moore, D.E. and Byerlee, J., 1992. Relationships between sliding behavior and internal geometry of laboratory fault zones and some creeping and locked strike-slip faults of California. In: T. Mikumo, K. Aki, M. Ohnaka, L.J. Ruff and P.K.P. Spudich (Editors), Earthquake Source Physics and Earthquake Precursors. Tectonophysics, 211: 305-316. In order to relate fault geometries to sliding behavior, maps of recently active breaks within the Hayward fault of central California, which is characterized by fault creep, have been examined and compared to maps of the San Andreas fault. The patterns of recent breaks of the Hayward fault are consistent with those found within the creeping section of the San Andreas, and they appear to have plausible physical explanations in the findings of laboratory experiments. The distinguishing geometric features of the examined locked and creeping faults are: (1) P-type second-order traces predominate over R(Riedel)-type traces in creeping sections; and (2) R-type second-order traces make smaller angles to the local fault strike in creeping sections than they do in locked sections. Two different maps of the Hayward fault gave similar results, supporting the inference that the patterns identified are basic characteristics of the fault rather than artifacts of a particular mapping procedure. P shears predominate over R shears under laboratory conditions that allow dilation within the fault zone. In our own experiments, P-shear development was favored by the generation of excess pore-fluid pressures. We propose that creep in California faults also is the result of fluid overpressures that are maintained in a low-permeability gouge zone and that significantly lower effective stresses, thus helping to stabilize slip and producing high values of the ratio P/R. Small R-trace angles may also be an indicator of low effective stresses, but the evidence for this is not conclusive because other factors can also affect the size of the angles. ?? 1992.
A novel cell culture model as a tool for forensic biology experiments and validations.
Feine, Ilan; Shpitzen, Moshe; Roth, Jonathan; Gafny, Ron
2016-09-01
To improve and advance DNA forensic casework investigation outcomes, extensive field and laboratory experiments are carried out in a broad range of relevant branches, such as touch and trace DNA, secondary DNA transfer and contamination confinement. Moreover, the development of new forensic tools, for example new sampling appliances, by commercial companies requires ongoing validation and assessment by forensic scientists. A frequent challenge in these kinds of experiments and validations is the lack of a stable, reproducible and flexible biological reference material. As a possible solution, we present here a cell culture model based on skin-derived human dermal fibroblasts. Cultured cells were harvested, quantified and dried on glass slides. These slides were used in adhesive tape-lifting experiments and tests of DNA crossover confinement by UV irradiation. The use of this model enabled a simple and concise comparison between four adhesive tapes, as well as a straightforward demonstration of the effect of UV irradiation intensities on DNA quantity and degradation. In conclusion, we believe this model has great potential to serve as an efficient research tool in forensic biology. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Preparation and Wear Resistance of Aluminum Composites Reinforced with In Situ Formed TiO/Al2O3
NASA Astrophysics Data System (ADS)
Qin, Q. D.; Huang, B. W.; Li, W.; Zeng, Z. Y.
2016-05-01
An in situ TiO/Al2O3-reinforced Al composite is successfully prepared using a powder metallurgy route by the reaction of Ti2CO and Al powder. The Ti2CO powder is produced by carrying out a carbothermic reduction of titanium dioxide at 1000 °C. XRD results show that the final product is composed of Al, TiO, Al2O3, and Al3Ti. Morphology examination of the composite reveals the presence of bigger blocks of TiO and fine particles of Al2O3 and the volume fraction of reinforcement is found to range between 18 and 55%. As the volume fraction of the reinforced materials approaches 50%, the particles start to agglomerate. Dry sliding wear tests conducted using a conventional pin-on-disk testing machine show that the wear resistance of the composite is higher than that of the pure aluminum ingot. The wear rate of the composite increases almost linearly with the increase in the wear distance. The sliding wear test shows that as the volume fraction of the reinforced phase increases, the coefficient of friction decreases. The wear mechanism is also discussed.
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Astrophysics Data System (ADS)
Price, P. B.
1982-06-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Definition study for an advanced cosmic ray experiment utilizing the long duration exposure facility
NASA Technical Reports Server (NTRS)
Price, P. B.
1982-01-01
To achieve the goals of cosmic ray astrophysics, an ultraheavy cosmic ray experiment on an LDEF reflight should be in an orbit with high inclination (approximately 57 deg) at approximately 230 nm for approximately 2 years near solar minimum (approximately 1986). It should fill 61 trays. Each tray should contain 4 modules of total active area 0.7 sq m, with a thermal blanket, thermal labyrinth mounts, aluminum honeycomb mechanical support, and total weight approximately 100 kg. Each module should contain interleaved CR39, Lexan, and thin copper sheets plus one event-thermometer canned in a thin metal cannister sealed with approximately 0.2 atm dry O2. The CR39 and Lexan should be manufactured to specifications and the sheet copper rolled to specifications. The event-thermometer should be a stiffened CR39 sheet that slides via bimetal strips relative to fixed CR39 sheet so that stack temperature can be read out for each event. The metal cannister can be collapsed at launch and landing, capturing the sliding assembly to prevent damage. An engineering study should be made of a prototype LDEF tray; this will include thermal and mechanical tests of detectors and the event thermometer.
Bioregenerative system components for microgravity
NASA Technical Reports Server (NTRS)
Nevill, Gale E., Jr.; Hessel, Michael I., Jr.
1992-01-01
The goal of the class was to design, fabricate, and test prototype designs that were independent, yet applicable to a Closed Loop Life Support System. The three prototypes chosen were in the areas of agar plant growth, regnerative filtration, and microgravity food preparation. The plant growth group designed a prototype agar medium growth system that incorporates nutrient solution replenishment and post-harvest refurbishment. In addition, the unit emphasizes material containment and minimization of open interfaces. The second project was a filter used in microgravity that has the capability to clean itself. The filters are perforated plates which slide through a duct and are cleaned outside of the flow with a vacuum system. The air in the duct is prevented from flowing outside of the duct by a network of sliding seals. The food preparation group developed a device which dispenses and mixes ingredients and then cooks the mixture in microgravity. The dry ingredients are dispensed from a canister by a ratchet-operated piston. The wet ingredients are dispensed from plastic bags through tubing attached to a syringe. Once inside the mixing chamber, the ingredients are mixed using a collapsible whisk and then pushed into the cooking device.
Gravimetric measurement of momentary drying rate of spray freeze-dried powders in vials.
Gieseler, Henning; Lee, Geoffrey
2009-09-01
The profile of drying rate versus primary drying time for a spray freeze-dried trehalose aqueous solution is much different from that determined for regular freeze-drying. Drying rate declines very rapidly, attributed to rate-limiting heat transfer through the packed bed of frozen microparticles contained in a vial. The inter-particulate spaces appear to be the cause of this rate limitation. Use of either liquid nitrogen or liquid propane as a cryogenic produced strong differences in both SFD particle morphology and drying rate using trehalose, sucrose, or mannitol. The lack of any evident correlation supports the argument that the inter-particulate voids determine drying behavior.
NASA Astrophysics Data System (ADS)
Im, Kyungjae; Elsworth, Derek; Marone, Chris; Leeman, John
2017-12-01
Interseismic frictional healing is an essential process in the seismic cycle. Observations of both natural and laboratory earthquakes demonstrate that the magnitude of stress drop scales with the logarithm of recurrence time, which is a cornerstone of the rate and state friction (RSF) laws. However, the origin of this log linear behavior and short time "cutoff" for small recurrence intervals remains poorly understood. Here we use RSF laws to demonstrate that the back-projected time of null-healing intrinsically scales with the initial frictional state θi. We explore this behavior and its implications for (1) the short-term cutoff time of frictional healing and (2) the connection between healing rates derived from stick-slip sliding versus slide-hold-slide tests. We use a novel, continuous solution of RSF for a one-dimensional spring-slider system with inertia. The numerical solution continuously traces frictional state evolution (and healing) and shows that stick-slip cutoff time also scales with frictional state at the conclusion of the dynamic slip process θi (=Dc/Vpeak). This numerical investigation on the origins of stick-slip response is verified by comparing laboratory data for a range of peak slip velocities. Slower slip motions yield lesser magnitude of friction drop at a given time due to higher frictional state at the end of each slip event. Our results provide insight on the origin of log linear stick-slip evolution and suggest an approach to estimating the critical slip distance on faults that exhibit gradual accelerations, such as for slow earthquakes.
Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides
NASA Astrophysics Data System (ADS)
Handwerger, Alexander L.; Rempel, Alan W.; Skarbek, Rob M.; Roering, Joshua J.; Hilley, George E.
2016-09-01
Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length
Freeze-Dried Carbon Nanotube Aerogels for High-Frequency Absorber Applications.
Anoshkin, Ilya V; Campion, James; Lioubtchenko, Dmitri V; Oberhammer, Joachim
2018-06-13
A novel technique for millimeter wave absorber material embedded in a metal waveguide is proposed. The absorber material is a highly porous carbon nanotube (CNT) aerogel prepared by a freeze-drying technique. CNT aerogel structures are shown to be good absorbers with a low reflection coefficient, less than -12 dB at 95 GHz. The reflection coefficient of the novel absorber is 3-4 times lower than that of commercial absorbers with identical geometry. Samples prepared by freeze-drying at -25 °C demonstrate resonance behavior, while those prepared at liquid nitrogen temperature (-196 °C) exhibit a significant decrease in reflection coefficient, with no resonant behavior. CNT absorbers of identical volume based on wet-phase drying preparation show significantly worse performance than the CNT aerogel absorbers prepared by freeze-drying. Treatment of the freeze-dried CNT aerogel with n- and p-dopants (monoethanolamine and iodine vapors, respectively) shows remarkable improvement in the performance of the waveguide embedded absorbers, reducing the reflection coefficient by 2 dB across the band.
Wang, Hua-Mei; Fu, Ting-Ming; Guo, Li-Wei
2013-02-01
To prepare panax notoginseng saponins-tanshinone II(A) composite particles for pulmonary delivery, in order to explore a dry powder particle preparation method ensuring synchronized arrival of multiple components of traditional Chinese medicine compounds at absorption sites. Panax notoginseng saponins-tanshinone II(A) composite particles were prepared with spray-drying method, and characterized by scanning electron microscopy (SEM), confocal laser scanning microscope (CLSM), X-ray diffraction (XRD), infrared analysis (IR), dry laser particle size analysis, high performance liquid chromatography (HPLC) and the aerodynamic behavior was evaluated by a Next Generation Impactor (NGI). The dry powder particles produced had narrow particle size distribution range and good aerodynamic behavior, and could realize synchronized administration of multiple components. The spray-drying method is used to combine traditional Chinese medicine components with different physical and chemical properties in the same particle, and product into traditional Chinese medicine compound particles in line with the requirements for pulmonary delivery.
Zheng, Anqing; Zhao, Zengli; Chang, Sheng; Huang, Zhen; Zhao, Kun; Wei, Guoqiang; He, Fang; Li, Haibin
2015-01-01
Wet and dry torrefaction of corncobs was conducted in high-pressure reactor and tube-type reactor, respectively. Effect of wet and dry torrefaction on chemical structure and pyrolysis behavior of corncobs was compared. The results showed that hemicellulose could be effectively removed from corncobs by torrefaction. However, dry torrefaction caused severe degradation of cellulose and the cross-linking and charring of corncobs. X-ray diffraction analysis revealed that crystallinity degree of corncobs was evidently enhanced during wet torrefaction, but reduced during dry torrefaction as raising treatment temperature. In thermogravimetric analysis, wet torrefied corncobs produced less carbonaceous residues than raw corncobs, while dry torrefied corncobs gave much more residues owing to increased content of acid insoluble lignin. Pyrolysis-gas chromatography/mass spectroscopy analysis indicated that wet torrefaction significantly promoted levoglucosan yield owing to the removal of alkali metals. Therefore, wet torrefaction can be considered as a more effective pretreatment method for fast pyrolysis of biomass. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higa, Kenneth; Zhao, Hui; Parkinson, Dilworth Y.
The internal structure of a porous electrode strongly influences battery performance. Understanding the dynamics of electrode slurry drying could aid in engineering electrodes with desired properties. For instance, one might monitor the dynamic, spatially-varying thickness near the edge of a slurry coating, as it should lead to non-uniform thickness of the dried film. This work examines the dynamic behavior of drying slurry drops consisting of SiO x and carbon black particles in a solution of carboxymethylcellulose and deionized water, as an experimental model of drying behavior near the edge of a slurry coating. An X-ray radiography-based procedure is developed tomore » calculate the evolving spatial distribution of active material particles from images of the drying slurry drops. To the authors’ knowledge, this study is the first to use radiography to investigate battery slurry drying, as well as the first to determine particle distributions from radiography images of drying suspensions. The dynamic results are consistent with tomography reconstructions of the static, fully-dried films. It is found that active material particles can rapidly become non-uniformly distributed within the drops. Heating can promote distribution uniformity, but seemingly must be applied very soon after slurry deposition. Higher slurry viscosity is found to strongly restrain particle redistribution.« less
NASA Technical Reports Server (NTRS)
Tanner, J. A.; Stubbs, S. M.; Smith, E. G.
1981-01-01
The investigation utilized one main gear wheel, brake, and tire assembly of a McDonnell Douglas DC-9 series 10 airplane. The landing-gear strut was replaced by a dynamometer. During maximum braking, average braking behavior indexes based upon brake pressure, brake torque, and drag-force friction coefficient developed by the antiskid system were generally higher on dry surfaces than on wet surfaces. The three braking behavior indexes gave similar results but should not be used interchangeably as a measure of the braking of this antiskid sytem. During the transition from a dry to a flooded surface under heavy braking, the wheel entered into a deep skid but the antiskid system reacted quickly by reducing brake pressure and performed normally during the remainder of the run on the flooded surface. The brake-pressure recovery following transition from a flooded to a dry surface was shown to be a function of the antiskid modulating orifice.
Nanocrystalline mirror-slip surfaces in calcite gouge sheared at sub-seismic slip rates
NASA Astrophysics Data System (ADS)
Verberne, B. A.; Plümper, O.; de Winter, D.; Niemeijer, A. R.; Spiers, C. J.
2013-12-01
If seismic-aseismic transitions in fault rocks are to be recognized from microstructures preserved in natural fault rocks, an understanding of the microphysical mechanisms that produce such microstructures is needed. We report on microstructures recovered from dry direct shear experiments on (simulated) dry calcite gouge, performed at 50 MPa normal stress, 18-150°C and low sliding velocities (0.1-10 μm/s). The mechanical data show a transition from velocity strengthening below ~80°C to velocity weakening slip at higher temperatures. We investigated both loose gouge fragments and thin sections, characterizing the microstructures at the mm- to nm-scales. All deformed samples split along a shear band fabric defined by mainly R1- and boundary shears. Viewed normal to the shear plane, these bands commonly showed shiny, elongate patches aligned, and striated, parallel to the shear direction. These patches were especially common in samples tested below 80°C, though shear band splitting was less well-developed above 80°C so that even if the shiny patches formed at higher temperature they were less frequently exposed. Scanning Electron Microscopy (SEM) applied to shiny patches formed in samples sheared at room temperature showed the presence of elongate, streaked out sub-micron-sized particles oriented parallel to the shear direction. Transmitted light optical microscopy of thin sections cut normal to the shear plane and parallel to the shear direction, combined with Focused Ion Beam (FIB) - SEM on loose gouge fragments, showed that the shiny surfaces correspond with shear bands characterized by extreme grain size reduction and sintered sub-micron-particles. Transmission Electron Microscopy (TEM) further revealed that the cores of the shear bands consist of nanocrystallites some 20 nm in size, with a Crystallographic Preferred Orientation (CPO). Our results demonstrate that mirror-like nanocrystalline slip zones can form in calcite gouge sheared at shallow crustal conditions at sub-seismic sliding velocities, in velocity strengthening as well as velocity weakening samples. This means that their presence cannot be used as a single diagnostic indicator for seismic slip in natural fault rocks. Our SEM and TEM observations suggest that, at room temperature, the frictional behavior of the shear bands is dominated by crystal plastic plus nanogranular flow mechanisms, rather than by brittle deformation processes - as inferred for frictional slip in some metals. We further suggest that it is the thermally activated nature of crystal plasticity that is responsible for the transition from velocity strengthening to velocity weakening slip that we observed at ~80°C. The inferred mechanism has important implications for understanding both the depth range of seismicity and the seismic cycle in tectonically-active carbonate terrains.
Cornelius, Mary L; Osbrink, Weste L A
2010-06-01
This study examined the influence of soil type and moisture availability on termite foraging behavior. Physical properties of the soil affected both tunneling behavior and shelter tube construction. Termites tunneled through sand faster than top soil and clay. In containers with top soil and clay, termites built shelter tubes on the sides of the containers. In containers with sand, termites built shelter tubes directly into the air and covered the sides of the container with a layer of sand. The interaction of soil type and moisture availability affected termite movement, feeding, and survival. In assays with moist soils, termites were more likely to aggregate in top soil over potting soil and peat moss. However, termites were more likely to move into containers with dry peat moss and potting soil than containers with dry sand and clay. Termites were also significantly more likely to move into containers with dry potting soil than dry top soil. In the assay with dry soils, termite mortality was high even though termites were able to travel freely between moist sand and dry soil, possibly due to desiccation caused by contact with dry soil. Evaporation from potting soil and peat moss resulted in significant mortality, whereas termites were able to retain enough moisture in top soil, sand, and clay to survive for 25 d. The interaction of soil type and moisture availability influences the distribution of foraging termites in microhabitats.
An in vitro investigation on friction generated by ceramic brackets.
Tecco, Simona; Teté, Stefano; Festa, Mario; Festa, Felice
2010-01-01
To compare friction (F) of conventional and ceramic brackets (0.022-inch slot) using a model that tests the sliding of the archwire through 10 aligned brackets. Polycrystalline alumina brackets (PCAs), PCA brackets with a stainless steel slot (PCA-M), and monocrystalline sapphire brackets (MCS) were tested under elastic ligatures using various archwires in dry and wet (saliva) states. Conventional stainless steel brackets were used as controls. In both dry and wet states, PCA and MCS brackets expressed a statistically significant higher F value with respect to stainless steel and PCA-M brackets when combined with the rectangular archwires (P<.01). PCA brackets showed significantly higher friction than MCS brackets (P<.01) when coupled with 0.014 x 0.025-inch nickel-titanium (Ni-Ti) archwire. SEM analysis showed differences in the surfaces among stainless steel, MCS, PCA-M, and PCA brackets. In the wet state, the mean F values were generally higher than in the dry state. PCA brackets showed significantly higher F than MCS brackets only when combined with 0.014 x 0.025-inch Ni-Ti archwires. Thus, in this study, a 10 aligned-brackets study model showed similar results when compared to a single bracket system except for friction level with 0.014 × 0.025-inch Ni-Ti archwires. © 2011 BY QUINTESSENCE PUBLISHING CO, INC.
Raman spectroscopy of dried synovial fluid droplets as a rapid diagnostic for knee joint damage
NASA Astrophysics Data System (ADS)
Esmonde-White, Karen A.; Mandair, Gurjit S.; Raaii, Farhang; Roessler, Blake J.; Morris, Michael D.
2008-02-01
Human synovial fluid droplets were investigated using drop deposition in combination with Raman spectroscopy. Following informed consent, synovial fluid was obtained from forty human patients with various severities of knee pain and/or osteoarthritis at the time of knee arthroscopy or total joint replacement. Synovial fluid was aspirated from the knee joint of each patient and stored at -80°C until examination by near-infrared Raman spectroscopy. Synovial fluid aspirates from the knee joint of each patient were deposited onto a clean fused silica microscope slide and the droplet dried under ambient laboratory conditions. Each droplet was illuminated by a line-focused or a ring-focused 785 nm laser. As the droplet dries, biofluid components segregated based on solubility differences and a deposit that is spatially heterogeneous was made. Spectra taken from the droplet edges and center were dominated by protein bands and showed the presence of at least two protein moieties in the droplet. Band area and band height ratios (1410 cm -1/1450 cm -1) showed the greatest change between specimens from patients with mild/early osteoarthritis compared to those with severe/late stage osteoarthritis. The greatest differences were found in the center of the droplet, which contains more soluble protein components than the edges.
``Coffee-ring'' patterns of polymer droplets
NASA Astrophysics Data System (ADS)
Biswas, Nupur; Datta, Alokmay
2013-02-01
Dried droplets of polymer solutions carries the self-assembly behavior of polymer molecules by forming various patterns. Pattern formation is a consequence of deposition of molecules depending on motion of the contact line during the drying process. The contact line motion depends on initial polymer concentrations and hence entanglement. Thus depending on entanglement the patterns represent the `particle' like or `collective' behavior of polymer molecules.
We implanted radio tags in adult bullfrogs from three ponds located in a Willamette Valley game reserve to determine their behavior and habitat use as the ponds dried during late summer. We used radio telemetry and a Global Position System (GPS) to locate and record the position ...
NASA Astrophysics Data System (ADS)
Dikmen, Erkan; Ayaz, Mahir; Gül, Doğan; Şahin, Arzu Şencan
2017-07-01
The determination of drying behavior of herbal plants is a complex process. In this study, gene expression programming (GEP) model was used to determine drying behavior of herbal plants as fresh sweet basil, parsley and dill leaves. Time and drying temperatures are input parameters for the estimation of moisture ratio of herbal plants. The results of the GEP model are compared with experimental drying data. The statistical values as mean absolute percentage error, root-mean-squared error and R-square are used to calculate the difference between values predicted by the GEP model and the values actually observed from the experimental study. It was found that the results of the GEP model and experimental study are in moderately well agreement. The results have shown that the GEP model can be considered as an efficient modelling technique for the prediction of moisture ratio of herbal plants.
Lin, Naiming; Liu, Qiang; Zou, Jiaojuan; Guo, Junwen; Li, Dali; Yuan, Shuo; Ma, Yong; Wang, Zhenxia; Wang, Zhihua; Tang, Bin
2016-01-01
Surface texturing-plasma nitriding duplex treatment was conducted on AISI 316 stainless steel to improve its tribological performance. Tribological behaviors of ground 316 substrates, plasma-nitrided 316 (PN-316), surface-textured 316 (ST-316), and duplex-treated 316 (DT-316) in air and under grease lubrication were investigated using a pin-on-disc rotary tribometer against counterparts of high carbon chromium bearing steel GCr15 and silicon nitride Si3N4 balls. The variations in friction coefficient, mass loss, and worn trace morphology of the tested samples were systemically investigated and analyzed. The results showed that a textured surface was formed on 316 after electrochemical processing in a 15 wt % NaCl solution. Grooves and dimples were found on the textured surface. As plasma nitriding was conducted on a 316 substrate and ST-316, continuous and uniform nitriding layers were successfully fabricated on the surfaces of the 316 substrate and ST-316. Both of the obtained nitriding layers presented thickness values of more than 30 μm. The nitriding layers were composed of iron nitrides and chromium nitride. The 316 substrate and ST-316 received improved surface hardness after plasma nitriding. When the tribological tests were carried out under dry sliding and grease lubrication conditions, the tested samples showed different tribological behaviors. As expected, the DT-316 samples revealed the most promising tribological properties, reflected by the lowest mass loss and worn morphologies. The DT-316 received the slightest damage, and its excellent tribological performance was attributed to the following aspects: firstly, the nitriding layer had high surface hardness; secondly, the surface texture was able to capture wear debris, store up grease, and then provide continuous lubrication. PMID:28773996
NASA Astrophysics Data System (ADS)
Tamilarasan, T. R.; Sanjith, U.; Rajendran, R.; Rajagopal, G.; Sudagar, J.
2018-03-01
Electroless composite coatings with various concentrations of reduced graphene oxide (rGO) particles were deposited onto mild steel substrate. The effects of adding rGO particles by varying their concentration from 0 to 100 mg/L on morphology, composition, microhardness, adhesion, wear and friction of the electroless composite coatings were investigated. Among the various parameters that influence the tribological behavior, sliding velocity was varied within a specific range for definite concentrations of rGO to obtain enhanced wear resistance in this study. The micrographs of the worn surfaces and indented spots were examined for the nature of wear mechanism and interfacial adhesion. The wear rate increased with increasing sliding velocity but was relatively stable for coatings with lower concentrations of rGO.
Electronic properties of long DNA nanowires in dry and wet conditions
NASA Astrophysics Data System (ADS)
Mousavi, Hamze; Khodadadi, Jabbar; Grabowski, Marek
2015-11-01
The electronic behavior of the long disordered DNA nanowires in both dry and wet conditions is investigated through the band structure and density of states of a tight-binding Hamiltonian model for π-electrons of the backbone, using Green's functions approach. For a chosen set of parameters in the dry case, semiconducting behavior is reproduced. It is also shown that for sufficiently long strands, the order of the base pairs has no noticeable effect on the energy band-gap. Moreover, this semiconducting duplex shows metallic tendencies when interacting with the environment of polar molecules.
Children's Implicit Personality Theories as Predictors of Their Social Judgments.
ERIC Educational Resources Information Center
Erdley, Cynthia A.; Dweck, Carol S.
1993-01-01
Fourth and fifth graders viewed a slide show that depicted a boy displaying negative behaviors and that had a negative consistent or a positive inconsistent ending. Children who believed that personality is fixed, but not children who believed personality is malleable, did not differ in their ratings of the boy in the consistent- and…
Person Perception and Verbal Labeling: The Development of Social Labels.
ERIC Educational Resources Information Center
Brooks-Gunn, Jeanne; Lewis, Michael
This study examined the social labels which are first used by infants, social differentiation on the basis of labeling behavior, and overgeneralization of social labels. Subjects were 81 infants from 9 to 36 months of age. The 9- to 24-month-olds were shown slides of themselves, their mothers, their fathers, and unfamiliar children, babies, and…
NASA Astrophysics Data System (ADS)
Zhang, Z.
2015-12-01
A large amount of radioactivity was discharged by the accident of FDNPP. The long half-life radionuclide, 137Cs was transported through the atmosphere mainly as the aerosol form and deposited to the forests in Fukushima prefecture. After the dry deposition of the 137Cs, the foliar uptake process would occur. To evaluate environmental transfer of radionuclides, the dry deposition and following foliar uptake is very important. There are some pioneering studies for radionuclide foliar uptake with attaching the solution containing stable target element on the leaf, however, cesium oxide aerosols were used for these deposition study [1]. In the FDNPP case, 137Cs was transported in sulfate aerosol form [2], so the oxide aerosol behaviors could not represent the actual deposition behavior in this accident. For evaluation of whole behavior of 137Cs in vegetation system, fundamental data for deposition and uptake process of sulfate aerosol was desired. In this study, we developed aerosol generation system for simulating the dry deposition and the foliar uptake behaviors of aerosol in the different chemical constitutions. In this system, the method of aerosol generation based on the spray drying. Solution contained 137Cs was send to a nozzle by a syringe pump and spraying with a high speed air flow. The sprayed mist was generated in a chamber in the relatively high temperature. The solution in the mist was dried quickly, and micro size solid aerosols consisting 137Cs were generated. The aerosols were suctioned by an ejector and transported inside a tube by the dry air flow, then were directly blown onto the leaves. The experimental condition, such as the size of chamber, chamber temperature, solution flow rate, air flow rate and so on, were optimized. In the deposition experiment, the aerosols on leaves were observed by a SEM/EDX system and the deposition amount was evaluated by measuring the stable Cs remaining on leaf. In the presentation, we will discuss the detail results of aerosol deposition behavior using the developed system. [1]C.Madoz-Escande, et al., Journal of Environmental Radioactivity, 73 pp49-71, (2004) [2] N. Kaneyasu, et al.,Environmental Science & Technology, 2012, 46 (11), pp 5720-5726
Tunneling behavior of the formosan subterranean termite (isoptera: rhinotermitadae) in dry soil
USDA-ARS?s Scientific Manuscript database
This study examines the effect of dry soil on tunnel construction by the Formosan subterranean termite, Cptotermes formosanus. Termites did not construct tunnels in dry soil in any of the treatments. Termites only constructed tunnels in moist areas in treatments where the soil was partially moistene...
Corrosion protection of steel by thin coatings of starch-oil dry lubricants
USDA-ARS?s Scientific Manuscript database
Corrosion of materials is one of the most serious and challenging problems faced worldwide by industry. Dry lubricants reduce friction between two metal surfaces. This research investigated the inhibition of corrosive behavior a dry lubricant formulation consisting of jet-cooked corn starch and soyb...
Sun, Y; Dearnley, P A; Mallia, Bertram
2017-08-01
Two duplex coatings, Cr(N)/S and Cr(C)/S, were deposited on 316 L stainless steel by magnetron sputtering. The effectiveness of these duplex coatings in improving the tribocorrosion behavior of medical alloys under elastic contact conditions has been demonstrated in a recent publication. The present work focused on the response of these duplex coatings to tribocorrosion under plastic contact conditions. Tribocorrosion tests were conducted in 0.89% NaCl solution at 37°C at an initial contact pressure of 740 MPa and under unidirectional sliding conditions for sliding duration up to 24 h. The results showed that during sliding in the corrosive solution, the duplex coatings were plastically deformed into the substrate to a depth about 1 μm. The Cr(C)/S duplex coating had sufficient ductility to accommodate the deformation without cracking, such that it was worn through gradually, leading to the gradual increase in open circuit potential (OCP) and coefficient of friction (COF). On the other hand, the Cr(N)/S duplex coating suffered from cracking at all tested potentials, leading to coating blistering after prolonged sliding at OCP and stable pit formation in the substrate beneath the coating at applied anodic potentials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1503-1513, 2017. © 2016 Wiley Periodicals, Inc.
Emergence of flagellar beating from the collective behavior of individual ATP-powered dyneins
NASA Astrophysics Data System (ADS)
Namdeo, S.; Onck, P. R.
2016-10-01
Flagella are hair-like projections from the surface of eukaryotic cells, and they play an important role in many cellular functions, such as cell-motility. The beating of flagella is enabled by their internal architecture, the axoneme, and is powered by a dense distribution of motor proteins, dyneins. The dyneins deliver the required mechanical work through the hydrolysis of ATP. Although the dynein-ATP cycle, the axoneme microstructure, and the flagellar-beating kinematics are well studied, their integration into a coherent picture of ATP-powered flagellar beating is still lacking. Here we show that a time-delayed negative-work-based switching mechanism is able to convert the individual sliding action of hundreds of dyneins into a regular overall beating pattern leading to propulsion. We developed a computational model based on a minimal representation of the axoneme consisting of two representative doublet microtubules connected by nexin links. The relative sliding of the microtubules is incorporated by modeling two groups of ATP-powered dyneins, each responsible for sliding in opposite directions. A time-delayed switching mechanism is postulated, which is key in converting the local individual sliding action of multiple dyneins into global beating. Our results demonstrate that an overall nonreciprocal beating pattern can emerge with time due to the spatial and temporal coordination of the individual dyneins. These findings provide insights in the fundamental working mechanism of axonemal dyneins and could possibly open new research directions in the field of flagellar motility.
Emergence of flagellar beating from the collective behavior of individual ATP-powered dyneins.
Namdeo, S; Onck, P R
2016-10-01
Flagella are hair-like projections from the surface of eukaryotic cells, and they play an important role in many cellular functions, such as cell-motility. The beating of flagella is enabled by their internal architecture, the axoneme, and is powered by a dense distribution of motor proteins, dyneins. The dyneins deliver the required mechanical work through the hydrolysis of ATP. Although the dynein-ATP cycle, the axoneme microstructure, and the flagellar-beating kinematics are well studied, their integration into a coherent picture of ATP-powered flagellar beating is still lacking. Here we show that a time-delayed negative-work-based switching mechanism is able to convert the individual sliding action of hundreds of dyneins into a regular overall beating pattern leading to propulsion. We developed a computational model based on a minimal representation of the axoneme consisting of two representative doublet microtubules connected by nexin links. The relative sliding of the microtubules is incorporated by modeling two groups of ATP-powered dyneins, each responsible for sliding in opposite directions. A time-delayed switching mechanism is postulated, which is key in converting the local individual sliding action of multiple dyneins into global beating. Our results demonstrate that an overall nonreciprocal beating pattern can emerge with time due to the spatial and temporal coordination of the individual dyneins. These findings provide insights in the fundamental working mechanism of axonemal dyneins and could possibly open new research directions in the field of flagellar motility.
Ghabraei, Soheil; Moradi, Hamed; Vossoughi, Gholamreza
2015-09-01
To guarantee the safety and efficient performance of the power plant, a robust controller for the boiler-turbine unit is needed. In this paper, a robust adaptive sliding mode controller (RASMC) is proposed to control a nonlinear multi-input multi-output (MIMO) model of industrial boiler-turbine unit, in the presence of unknown bounded uncertainties and external disturbances. To overcome the coupled nonlinearities and investigate the zero dynamics, input-output linearization is performed, and then the new decoupled inputs are derived. To tackle the uncertainties and external disturbances, appropriate adaption laws are introduced. For constructing the RASMC, suitable sliding surface is considered. To guarantee the sliding motion occurrence, appropriate control laws are constructed. Then the robustness and stability of the proposed RASMC is proved via Lyapunov stability theory. To compare the performance of the purposed RASMC with traditional control schemes, a type-I servo controller is designed. To evaluate the performance of the proposed control schemes, simulation studies on nonlinear MIMO dynamic system in the presence of high frequency bounded uncertainties and external disturbances are conducted and compared. Comparison of the results reveals the superiority of proposed RASMC over the traditional control schemes. RAMSC acts efficiently in disturbance rejection and keeping the system behavior in desirable tracking objectives, without the existence of unstable quasi-periodic solutions. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zou, Zongxing; Tang, Huiming; Xiong, Chengren; Su, Aijun; Criss, Robert E.
2017-10-01
The Jiweishan rockslide of June 5, 2009 in China provides an important opportunity to elucidate the kinetic characteristics of high-speed, long-runout debris flows. A 2D discrete element model whose mechanical parameters were calibrated using basic field data was used to simulate the kinetic behavior of this catastrophic landslide. The model output shows that the Jiweishan debris flow lasted about 3 min, released a gravitational potential energy of about 6 × 10^13 J with collisions and friction dissipating approximately equal amounts of energy, and had a maximum fragment velocity of 60-70 m/s, almost twice the highest velocity of the overall slide mass (35 m/s). Notable simulated characteristics include the high velocity and energy of the slide material, the preservation of the original positional order of the slide blocks, the inverse vertical grading of blocks, and the downslope sorting of the slide deposits. Field observations that verify these features include uprooted trees in the frontal collision area of the air-blast wave, downslope reduction of average clast size, and undamaged plants atop huge blocks that prove their lack of downslope tumbling. The secondary acceleration effect and force chains derived from the numerical model help explain these deposit features and the long-distance transport. Our back-analyzed frictions of the motion path in the PFC model provide a reference for analyzing and predicting the motion of similar geological hazards.
NASA Astrophysics Data System (ADS)
Naydenkin, E. V.; Mishin, I. P.; Ivanov, K. V.
2015-04-01
The special features of the deformation behavior of an ultrafine-grained aluminum alloy produced by severe plastic deformation are investigated. Unlike ultrafine-grained pure aluminum, the second-phase particles precipitated in the bulk and at the grain boundaries of the alloy are shown to hinder the development of grain boundary sliding and plastic strain localization. This increases the length of the strain hardening stage and uniformity of elongation of a heterogeneous aluminum alloy specimen as compared to pure aluminum.
Drying kinetics and mathematical modeling of hot air drying of coconut coir pith.
Fernando, J A K M; Amarasinghe, A D U S
2016-01-01
Drying kinetics of coir pith was studied and the properties of compressed coir pith discs were analyzed. Coir pith particles were oven dried in the range of temperatures from 100 to 240 °C and the rehydration ability of compressed coir pith was evaluated by finding the volume expansion. The optimum drying temperature was found to be 140 °C. Hot air drying was carried out to examine the drying kinetics by allowing the coir pith particles to fluidize and circulate inside the drying chamber. Particle motion within the drying chamber closely resembled the particle motion in a flash dryer. The effective moisture diffusivity was found to increase from 1.18 × 10(-8) to 1.37 × 10(-8) m(2)/s with the increase of air velocity from 1.4 to 2.5 m/s respectively. Correlation analysis and residual plots were used to determine the adequacy of existing mathematical models for describing the drying behavior of coir pith. The empirical models, Wang and Singh model and Linear model, were found to be adequate for accurate prediction of drying behavior of coir pith. A new model was proposed by modifying the Wang and Singh model and considering the effect of air velocity. It gave the best correlation between observed and predicted moisture ratio with high value of coefficient of determination (R(2)) and lower values of root mean square error, reduced Chi square (χ(2)) and mean relative deviation (E%).
NASA Astrophysics Data System (ADS)
Zou, Changwei; Xie, Wei; Tang, Xiaoshan
2016-11-01
In this study, the effects of nitrogen codoping on the microstructure and mechanical properties of Cr-doped diamond-like carbon (DLC) nanocomposite coatings were investigated in detail. Compared with undoped DLC coatings, the Cr-DLC and N/Cr-DLC coatings showed higher root-mean-square (RMS) roughness values. However, from the X-ray photoelectron spectroscopy (XPS) and Raman results, the fraction of sp2 carbon bonds of N/Cr-DLC coatings increased with increasing N content, which indicated the graphitization of the coatings. The hardness and elastic modulus of N/Cr-DLC coatings with 1.8 at. % N were about 26.8 and 218 GPa, respectively. The observed hardness increase with N codoping was attributed to the incorporation of N in the C network along with the formation of CrC(N) nanoparticles, as confirmed from the transmission electron microscopy (TEM) results. The internal stress markedly decreased from 0.93 to 0.32 GPa as the N content increased from 0 to 10.3 at. %. Furthermore, N doping significantly improved the high-temperature dry friction behavior of DLC coatings. The friction coefficient of N/Cr-DLC coatings with 8.0 and 10.3 at. % N was kept at about 0.2 during the overall sliding test at 500 °C. These results showed that appropriate N doping could promote the mechanical and tribological properties of Cr-DLC nanocomposite coatings.
Zhuang, Qiaoqiao; Zhang, Peilei; Li, Mingchuan; Yan, Hua; Yu, Zhishui; Lu, Qinghua
2017-10-30
The Ni-Ti-Si composite coatings were successfully fabricated on Ti6Al4V by laser cladding. The microstructure were studied by SEM (scanning electron microscopy) and EDS (energy dispersive spectrometer). It has been found that Ti₂Ni and Ti₅Si₃ phases exist in all coatings, and some samples have TiSi₂ phases. Moreover, due to the existence of these phases, coatings presented relatively higher microhardness than that of the substrate (826 HV (Vickers hardness)) and the microhardness value of coating 3 is about twice larger than that of the substrate. During the dry sliding friction and wear test, due to the distribution of the relatively ductile phase of Ti₂Ni and reinforcement phases of Ti₅Si₃ and TiSi₂, the coatings performed good wear resistance. The oxidation process contains two stages: the rapid oxidation and slow oxidation by high temperature oxidation test at 800 °C for 50 h. Meanwhile, the value of the oxidation weight gain of the substrate is approximately three times larger than that of the coating 4. During the oxidation process, the oxidation film formed on the coating is mainly consisted of TiO₂, Al₂O₃ and SiO₂. Phases Ti₂Ni, Ti₅Si₃, TiSi₂ and TiSi were still found and it could be responsible for the improvement in oxidation resistance of the coatings by laser cladding.
A qualitative evaluation of hand drying practices among Kenyans.
Person, Bobbie; Schilling, Katharine; Owuor, Mercy; Ogange, Lorraine; Quick, Rob
2013-01-01
Recommended disease prevention behaviors of hand washing, hygienic hand drying, and covering one's mouth and nose in a hygienic manner when coughing and sneezing appear to be simple behaviors but continue to be a challenge to successfully promote and sustain worldwide. We conducted a qualitative inquiry to better understand current hand drying behaviors associated with activities of daily living, and mouth and nose covering practices, among Kenyans. We conducted 7 focus group discussions; 30 in-depth interviews; 10 structured household observations; and 75 structured observations in public venues in the urban area of Kisumu; rural communities surrounding Kisumu; and a peri-urban area outside Nairobi, Kenya. Using a grounded theory approach, we transcribed and coded the narrative data followed by thematic analysis of the emergent themes. Hand drying, specifically on a clean towel, was not a common practice among our participants. Most women dried their hands on their waist cloth, called a leso, or their clothes whether they were cooking, eating or cleaning the nose of a young child. If men dried their hands, they used their trousers or a handkerchief. Children rarely dried their hands; they usually just wiped them on their clothes, shook them, or left them wet as they continued with their activities. Many people sneezed into their hands and wiped them on their clothes. Men and women used a handkerchief fairly often when they had a runny nose, cold, or the flu. Most people coughed into the air or their hand. Drying hands on dirty clothes, rags and lesos can compromise the benefits of handwashing. Coughing and sneezing in to an open hand can contribute to spread of disease as well. Understanding these practices can inform health promotion activities and campaigns for the prevention and control of diarrheal disease and influenza.
Geomorphology of the Arteara Holocene rock-avalanche deposit, Gran Canaria Island
NASA Astrophysics Data System (ADS)
Yepes, Jorge; Lomoschitz, Alejandro
2010-05-01
Abundant slide deposits cover the southern ravines of Grand Canary. These are mainly volcanic debris avalanches consisting of rock slides and debris slides. The main course of the Fataga ravine is entrenched 600m into the Phonolite Formation. At Arteara an accumulation of large reddish blocks has been characterised covering the right side of the ravine. The deposit has a surface area of 0.565 km2 and has been dated as a Holocene rock avalanche, because of its good state of conservation. The blocks cover a previous relief formed by a rock slide with a surface area of 1.236km2 and thought to be Pleistocene. The whole of the deposit is covered at its head by an active scree sequence. The rock slide deposit varies in thickness from 25m to 100m and has head and foot zones. The flanks are indicated by tributary streams with an arching course and anomalous confluence with the main ravine. Several fragmented rocky wedges can be seen at the head with local tilting against the slope. In addition, an elongated depression has formed coinciding with the fracture through the rocky wedges. This depression is partially masked by the rock avalanche deposits. The slide scar is hidden behind the rocky wedges, coinciding with the col between the Morro Garito and the erosion surface defined at the top of the Phonolite Formation. The foot of the rocky slide is affected by an incipient drainage network at present masked by the rock avalanche. These palaeochannels show the presence of several reactivation episodes that would have broken up the foot of the rock slide into several bodies. There is a mass of broken rock on the northern flank, presumably caused by a rock slide movement. There is a mass of disorganised rock in the central sector of the foot, probably caused by a debris slide-slump movement, as suggested by an elongated depression, the deformation of the layers and a reappearance of the deposit in the distal zone. This second gravitational deposit collided with the opposite side, where some remains can still be recognised. This was later covered by a layer of ordered rubble from the left bank. Blockage of the main course gave rise to an alluvial-torrential plain of boulders and gravels along the section upstream from Arteara. A network of braided channels has developed on this plain. At present, the advance of the rising erosion has cut through the slope deposit and is dismantling the alluvial-torrential plain. The rock avalanche defines an elongated tongue in the direction of flow, of varying thickness (1-15m) and L/H = 2.47 (displacement/total fall=1325m/535m), reappearing at the foot (Hr=15m). In general, the rock avalanche is adapted to the previous slide, although it has small overspill lobes on the lateral flanks. The low angle of friction deduced (=21.47°) agrees with the high mobility estimated from the L/H ratio and is due to the existence of a previous relief defined by the rock slide and the lubrication provided by the ignimbrite. This easily weathered material must have made up the gravel layer over which the lava blocks moved. The rock avalanche deposit varies widely in size and is structured in bands of loose blocks with a bimodal distribution (0.1-3m3; 10.30m3) and low selection. The blocks lie on a layer of loose, flat, angular gravels. The blocks are angular and show numerous signs of impact, including split and fragmented blocks, faces with conchoidal fractures, chipped edges and broken corners. The movement of the rock avalanche would have been a swift, dry granular flow. The avalanche would have had a leap component at the head, turbulent flow in the intermediate corridor and laminar flow in the distal zone. The leap component is identified by the accumulation of blocks in crests transversal to the flow and the presence of megablocks aligned with the flow. The turbulent component is identified by the chaotic accumulation of blocks in the palaeochannels and overspill lobes covering the flanks. The laminar component is identified by the bimodal distribution of blocks as concentric propagation waves. The available data are not sufficient to suggest a link between the rock avalanche and freeze-melt processes. However, evidence from several humid-subtropical episodes in the Quaternary suggests undermining of the scarp and triggering of the previous rock slide. The subsequent variation in the state of tensions on the shelf and the penetrating nature of the thermal retraction diaclases would justify the detachment of an approximately 2.82*106m3 block.
Roth, C; Winter, G; Lee, G
2001-09-01
The use of a novel microbalance (Christ) technique to monitor continuously the weight loss of a vial standing on a shelf of a freeze-dryer has been investigated. The drying rates of the following aqueous solutions were measured during the primary drying phase of a complete freeze-drying cycle: sucrose (75 mg/mL, 2.5-mL fill volume), sucrose and phenylalanine (1:0.2 by weight, 75 mg/mL, 2.5-mL fill volume), and mannitol (75mg/mL, 2.5-mL fill volume). The microbalance yields the cumulative water loss, m(cu) in grams, and the momentary drying rate, Deltam(cu)/Deltat in mg/10 min, of the frozen cake. The momentary drying rate curves were especially useful for examining how Deltam(cu)/Deltat changes with time during primary drying. Initially, Deltam(cu)/Deltat rises to a sharp maximum and then decreases in a fashion depending on shelf temperature, chamber pressure, and the nature of the substance being dried. Different drying behavior was observed for the sucrose and sucrose/phenylalanine systems, which was attributed to the presence of crystalline phenylalanine in the amorphous sucrose. At low shelf-temperature (-24 degrees C) the crystalline mannitol showed lower Deltam(cu)/Deltat than with either sucrose or sucrose/phenylalanine. The balance could also detect differences in Deltam(cu)/Deltat when using different freezing protocols. "Slow" and "moderate" freezing protocols gave similar drying behavior, but "rapid" freezing in liquid nitrogen produced greatly altered drying rate and internal cake morphology. The balance also could be used to detect the endpoint of primary drying. Different endpoint criteria and their influence on final dried cake properties were examined. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association
Injection molding ceramics to high green densities
NASA Technical Reports Server (NTRS)
Mangels, J. A.; Williams, R. M.
1983-01-01
The injection molding behavior of a concentrated suspension of Si powder in wax was studied. It was found that the injection molding behavior was a function of the processing techniques used to generate the powder. Dry ball-milled powders had the best molding behavior, while air classified and impact-milled powders demonstrated poorer injection moldability. The relative viscosity of these molding batches was studied as a function of powder properties: distribution shape, surface area, packing density, and particle morphology. The experimental behavior, in all cases, followed existing theories. The relative viscosity of an injection molding composition composed of dry ball-milled powders could be expressed using Farris' relation.
Behavior of a Liquid Bridge between Nonparallel Hydrophobic Surfaces.
Ataei, Mohammadmehdi; Chen, Huanchen; Amirfazli, Alidad
2017-12-26
When a liquid bridge is formed between two nonparallel identical surfaces, it can move along the surfaces. Literature indicates that the direction of bridge movement is governed by the wettability of surfaces. When the surfaces are hydrophilic, the motion of the bridge is always toward the cusp (intersection of the plane of the two bounding surfaces). On the other hand, the movement is hitherto thought to be always pointing away from the cusp when the surfaces are hydrophobic. In this study, through experiments, numerical simulations, and analytical reasoning, we demonstrate that for hydrophobic surfaces, wettability is not the only factor determining the direction of the motion. A new geometrical parameter, i.e., confinement (cf), was defined as the ratio of the distance of the farthest contact point of the bridge to the cusp, and that of the closest contact point to the cusp. The direction of the motion depends on the amount of confinement (cf). When the distance between the surfaces is large (resulting in a small cf), the bridge tends to move toward the cusp through a pinning/depinning mechanism of contact lines. When the distance between the surfaces is small (large cf), the bridge tends to move away from the cusp. For a specific system, a maximum cf value (cf max ) exists. A sliding behavior (i.e., simultaneous advancing on the wider side and receding on the narrower side) can also be seen when a liquid bridge is compressed such that the cf exceeds the cf max . Contact angle hysteresis (CAH) is identified as an underpinning phenomenon that together with cf fundamentally explains the movement of a trapped liquid between two hydrophobic surfaces. If there is no CAH, however, i.e., the case of ideal hydrophobic surfaces, the cf will be a constant; we show that the bridge slides toward the cusp when it is stretched, while it slides away from the cusp when it is compressed (note sliding motion is different from motion due to pinning/depinning mechanism of contact lines). As such, the displacement is only related to geometrical parameters such as the amount of compression (or stretching) and the dihedral angle between the surfaces.
NASA Astrophysics Data System (ADS)
Menezes, Pradeep L.; Kishore; Kailas, Satish V.; Lovell, Michael R.
2015-01-01
Surface texture influences friction during sliding contact conditions. In the present investigation, the effect of surface texture and roughness of softer and harder counter materials on friction during sliding was analyzed using an inclined scratch testing system. In the experiments, two test configurations, namely (a) steel balls against aluminum alloy flats of different surface textures and (b) aluminum alloy pins against steel flats of different surface textures, are utilized. The surface textures were classified into unidirectionally ground, 8-ground, and randomly polished. For a given texture, the roughness of the flat surfaces was varied using grinding or polishing methods. Optical profilometer and scanning electron microscope were used to characterize the contact surfaces before and after the experiments. Experimental results showed that the surface textures of both harder and softer materials are important in controlling the frictional behavior. The softer material surface textures showed larger variations in friction between ground and polished surfaces. However, the harder material surface textures demonstrated a better control over friction among the ground surfaces. Although the effect of roughness on friction was less significant when compared to textures, the harder material roughness showed better correlations when compared to the softer material roughness.
Wear Properties of ECAP-Processed AM80 Magnesium Alloy
NASA Astrophysics Data System (ADS)
Gopi, K. R.; Shivananda Nayaka, H.; Sahu, Sandeep
2017-07-01
AM80 magnesium alloy was subjected to equal-channel angular pressing (ECAP), and microstructural evolution was studied using scanning electron microscope (SEM). Grain size was found to decrease up to 3 µm after four passes. An increase in number of ECAP passes led to a corresponding increase in hardness of the processed samples. Unprocessed and ECAP-processed samples were subjected to wear test using pin-on-disk wear test machine to study the wear behavior. Effects of varying loads (30 and 40 N) with sliding distances (2500 and 5000 m) were studied. The results showed reduction in wear mass loss for the ECAP-processed samples in comparison with unprocessed condition. Coefficient of friction (COF) was studied for different loads, and improvement in COF values was observed for ECAP-processed samples compared to unprocessed condition. Worn surfaces were studied using SEM and energy-dispersive x-ray spectrometer, and they exhibited plastic deformation, delamination, plowing, wear debris and oxidation in the sliding direction. X-ray diffraction analysis was conducted on the worn surfaces to identify the phases. It revealed the presence of magnesium oxide and magnesium aluminum oxide which led to oxidation wear in the sliding direction. Wear mechanism was found to be abrasive and oxidation wear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esgin, U.; Özyürek, D.; Kaya, H., E-mail: hasan.kaya@kocaeli.edu.tr
In the present study, wear behaviors of Monel 400, Monel 404, Monel R-405 and Monel K-500 alloys produced by Powder Metallurgy (P/M) method were investigated. These compounds prepared from elemental powders were cold-pressed (600 MPa) and then, sintered at 1150°C for 2 hours and cooled down to the room temperature in furnace environment. Monel alloys produced by the P/M method were characterized through scanning electron microscope (SEM+EDS), X-ray diffraction (XRD), hardness and density measurements. In wear tests, standard pin-on-disk type device was used. Specimens produced within four different Monel Alloys were tested under 1ms{sup −1} sliding speed, under three different loadsmore » (20N, 30N and 40N) and five different sliding distances (400-2000 m). The results show that Monel Alloys have γ matrix and that Al{sub 0,9}Ni{sub 4,22} intermetallic phase was formed in the structure. Also, the highest hardness value was measured with the Monel K-500 alloy. In wear tests, the maximum weight loss according to the sliding distance, was observed in Monel 400 and Monel 404 alloys while the minimum weight loss was achieved by the Monel K-500 alloy.« less
The XPS depth profiling and tribological characterization of ion-plated gold on various metals
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Spalvins, T.; Buckley, D. H.
1983-01-01
Friction properties were measured with a gold film; the graded interface between gold and nickel substrate; and the nickel substrate. All sliding was conducted against hard silicon carbide pins in two processes. In the adhesive process, friction arises primarily from adhesion between sliding surfaces. In the abrasion process, friction occurs as a result of the hard pin sliding against the film, indenting into it, and plowing a series of grooves. Copper and 440 C stainless steel substrates were also used. Results indicate that the friction related to both adhesion and abrasion is influenced by coating depth. The trends in friction behavior as a function of film depth are, however, just the opposite. The graded interface exhibited the highest adhesion and friction, while the graded interface resulted in the lowest abrasion and friction. The coefficient of friction due to abrasion is inversely related to the hardness. The greater the hardness of the surface, the lower is the abrasion and friction. The microhardness in the graded interface exhibited the highest hardness due to an alloy hardening effect. Almost no graded interface between the vapor-deposited gold film and the substrates was detected.
Radiolytic and Thermal Process Relevant to Dry Storage of Spent Nuclear Fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marschman, Steven C.; Haustein, Peter E.; Madey, Theodore E.
1999-06-01
This project involves basic research in chemistry and physics aimed at providing information pertinent to the safe long-term dry storage of spent nuclear fuel (SNF), thousands of tons of which remain in water storage across the DOE complex. The Hanford Site K-Basins alone hold 2300 tons of spent fuel, much of it severely corroded, and similar situations exist at Savannah River and Idaho National Engineering and Environmental Laboratory. DOE plans to remove this fuel and seal it in overpack canisters for ''dry'' interim storage for up to 75 years while awaiting permanent disposition. Chemically bound water will remain in thismore » fuel even after the proposed drying steps, leading to possible long-term corrosion of the containers and/or fuel rods themselves, generation of H2 and O2 gas via radiolysis (which could lead to deflagration or detonation), and reactions of pyrophoric uranium hydrides. No thoroughly tested model is now available to predict fuel behavior during preprocessing, processing, or storage. In a collaborative effort among Rutgers University, Pacific Northwest National Laboratory, and Brookhaven National Laboratory, we are studying the radiolytic reaction, drying processes, and corrosion behavior of actual SNF materials and of pure and mixed-phase samples. We propose to determine what is omitted from current models: radiolysis of water adsorbed on or in hydrates or hydroxides, thermodynamics of interfacial phases, and kinetics of drying. A model will be developed and tested against actual fuel rod behavior to ensure validity and applicability to the problems associated with developing dry storage strategies for DOE-owned SNF.« less
Electrode Slurry Particle Density Mapping Using X-ray Radiography
Higa, Kenneth; Zhao, Hui; Parkinson, Dilworth Y.; ...
2017-01-05
The internal structure of a porous electrode strongly influences battery performance. Understanding the dynamics of electrode slurry drying could aid in engineering electrodes with desired properties. For instance, one might monitor the dynamic, spatially-varying thickness near the edge of a slurry coating, as it should lead to non-uniform thickness of the dried film. This work examines the dynamic behavior of drying slurry drops consisting of SiO x and carbon black particles in a solution of carboxymethylcellulose and deionized water, as an experimental model of drying behavior near the edge of a slurry coating. An X-ray radiography-based procedure is developed tomore » calculate the evolving spatial distribution of active material particles from images of the drying slurry drops. To the authors’ knowledge, this study is the first to use radiography to investigate battery slurry drying, as well as the first to determine particle distributions from radiography images of drying suspensions. The dynamic results are consistent with tomography reconstructions of the static, fully-dried films. It is found that active material particles can rapidly become non-uniformly distributed within the drops. Heating can promote distribution uniformity, but seemingly must be applied very soon after slurry deposition. Higher slurry viscosity is found to strongly restrain particle redistribution.« less
Laser capture microdissection of embryonic cells and preparation of RNA for microarray assays.
Redmond, Latasha C; Pang, Christopher J; Dumur, Catherine; Haar, Jack L; Lloyd, Joyce A
2014-01-01
In order to compare the global gene expression profiles of different embryonic cell types, it is first necessary to isolate the specific cells of interest. The purpose of this chapter is to provide a step-by-step protocol to perform laser capture microdissection (LCM) on embryo samples and obtain sufficient amounts of high-quality RNA for microarray hybridizations. Using the LCM/microarray strategy on mouse embryo samples has some challenges, because the cells of interest are available in limited quantities. The first step in the protocol is to obtain embryonic tissue, and immediately cryoprotect and freeze it in a cryomold containing Optimal Cutting Temperature freezing media (Sakura Finetek), using a dry ice-isopentane bath. The tissue is then cryosectioned, and the microscope slides are processed to fix, stain, and dehydrate the cells. LCM is employed to isolate specific cell types from the slides, identified under the microscope by virtue of their morphology. Detailed protocols are provided for using the currently available ArcturusXT LCM instrument and CapSure(®) LCM Caps, to which the selected cells adhere upon laser capture. To maintain RNA integrity, upon removing a slide from the final processing step, or attaching the first cells on the LCM cap, LCM is completed within 20 min. The cells are then immediately recovered from the LCM cap using a denaturing solution that stabilizes RNA integrity. RNA is prepared using standard methods, modified for working with small samples. To ensure the validity of the microarray data, the quality of the RNA is assessed using the Agilent bioanalyzer. Only RNA that is of sufficient integrity and quantity is used to perform microarray assays. This chapter provides guidance regarding troubleshooting and optimization to obtain high-quality RNA from cells of limited availability, obtained from embryo samples by LCM.
Gelabert, Pere; Sandoval-Velasco, Marcela; Olalde, Iñigo; Fregel, Rosa; Rieux, Adrien; Escosa, Raül; Aranda, Carles; Paaijmans, Krijn; Mueller, Ivo; Gilbert, M. Thomas P.; Lalueza-Fox, Carles
2016-01-01
Phylogenetic analysis of Plasmodium parasites has indicated that their modern-day distribution is a result of a series of human-mediated dispersals involving transport between Africa, Europe, America, and Asia. A major outstanding question is the phylogenetic affinity of the malaria causing parasites Plasmodium vivax and falciparum in historic southern Europe—where it was endemic until the mid-20th century, after which it was eradicated across the region. Resolving the identity of these parasites will be critical for answering several hypotheses on the malaria dispersal. Recently, a set of slides with blood stains of malaria-affected people from the Ebro Delta (Spain), dated between 1942 and 1944, have been found in a local medical collection. We extracted DNA from three slides, two of them stained with Giemsa (on which Plasmodium parasites could still be seen under the microscope) and another one consisting of dried blood spots. We generated the data using Illumina sequencing after using several strategies aimed at increasing the Plasmodium DNA yield: depletion of the human genomic (g)DNA content through hybridization with human gDNA baits, and capture-enrichment using gDNA derived from P. falciparum. Plasmodium mitochondrial genome sequences were subsequently reconstructed from the resulting data. Phylogenetic analysis of the eradicated European P. vivax mtDNA genome indicates that the European isolate is closely related to the most common present-day American haplotype and likely entered the American continent post-Columbian contact. Furthermore, the European P. falciparum mtDNA indicates a link with current Indian strains that is in agreement with historical accounts. PMID:27671660
Laser Capture Microdissection of Embryonic Cells and Preparation of RNA for Microarray Assays
Redmond, Latasha C.; Pang, Christopher J.; Dumur, Catherine; Haar, Jack L.; Lloyd, Joyce A.
2014-01-01
In order to compare the global gene expression profiles of different embryonic cell types, it is first necessary to isolate the specific cells of interest. The purpose of this chapter is to provide a step-by-step protocol to perform laser capture microdissection (LCM) on embryo samples and obtain sufficient amounts of high-quality RNA for microarray hybridizations. Using the LCM/microarray strategy on mouse embryo samples has some challenges, because the cells of interest are available in limited quantities. The first step in the protocol is to obtain embryonic tissue, and immediately cryoprotect and freeze it in a cryomold containing Optimal Cutting Temperature freezing media (Sakura Finetek), using a dry ice–isopentane bath. The tissue is then cryosectioned, and the microscope slides are processed to fix, stain, and dehydrate the cells. LCM is employed to isolate specific cell types from the slides, identified under the microscope by virtue of their morphology. Detailed protocols are provided for using the currently available ArcturusXT LCM instrument and CapSure® LCM Caps, to which the selected cells adhere upon laser capture. To maintain RNA integrity, upon removing a slide from the final processing step, or attaching the first cells on the LCM cap, LCM is completed within 20 min. The cells are then immediately recovered from the LCM cap using a denaturing solution that stabilizes RNA integrity. RNA is prepared using standard methods, modified for working with small samples. To ensure the validity of the microarray data, the quality of the RNA is assessed using the Agilent bioanalyzer. Only RNA that is of sufficient integrity and quantity is used to perform microarray assays. This chapter provides guidance regarding troubleshooting and optimization to obtain high-quality RNA from cells of limited availability, obtained from embryo samples by LCM. PMID:24318813
Effect of alumina on grain refinement of Al-Si hypereutectic alloys
NASA Astrophysics Data System (ADS)
Majhi, J.; Sahoo, S. K.; Patnaik, S. C.; Sarangi, B.; Sachan, N. K.
2018-03-01
The size, volume fraction and distribution of primary as well as eutectic silicon affect the mechanical properties of the Al-Si hypereutectic alloys. It is very difficult for the simultaneous refinement and modification of primary and secondary Si particles in hypereutectic Al-Si alloys through traditional processes. This paper explores the role of γ-Al2O3 nanoparticles on Si particles in the course of solidification in hypereutectic Al-Si alloys at particular pouring temperature. The present study involves incorporation of varying contents dispersed γ-Al2O3 nanoparticles into a molten base metal during stir casting and followed by solidification. It has been reported that the synthesized composites having good interfacial bonding (wetting) between the dispersed phase and the liquid matrix was achieved in order to provide improved mechanical properties of the composite. The cast product of hypereutectic Al-16Si alloy with the reinforcement of nanoparticles, illustrated a significant improvement in both wear behaviour and hardness. The dry sliding wear test has been performed on a group of specimens with varying parameters (different loads and sliding velocities) in a pin on disc wear testing machine. Moreover, the wear rate and specific wear rate also affected in different load and different sliding velocities. However in XRD analysis of the samples, the enhancement of wear resistance as well as hardness was due to the formation of brittle phases like SiO2, Al2O3 and Al-rich intermetallic compounds. The hardness value of the materials increases nearly 6% in addition to increase in the density of only 0.8%. As per literature, the large plate eutectic Si particles were modified in to the fine core particles and it acquires enough potential for various applications.
Gelabert, Pere; Sandoval-Velasco, Marcela; Olalde, Iñigo; Fregel, Rosa; Rieux, Adrien; Escosa, Raül; Aranda, Carles; Paaijmans, Krijn; Mueller, Ivo; Gilbert, M Thomas P; Lalueza-Fox, Carles
2016-10-11
Phylogenetic analysis of Plasmodium parasites has indicated that their modern-day distribution is a result of a series of human-mediated dispersals involving transport between Africa, Europe, America, and Asia. A major outstanding question is the phylogenetic affinity of the malaria causing parasites Plasmodium vivax and falciparum in historic southern Europe-where it was endemic until the mid-20th century, after which it was eradicated across the region. Resolving the identity of these parasites will be critical for answering several hypotheses on the malaria dispersal. Recently, a set of slides with blood stains of malaria-affected people from the Ebro Delta (Spain), dated between 1942 and 1944, have been found in a local medical collection. We extracted DNA from three slides, two of them stained with Giemsa (on which Plasmodium parasites could still be seen under the microscope) and another one consisting of dried blood spots. We generated the data using Illumina sequencing after using several strategies aimed at increasing the Plasmodium DNA yield: depletion of the human genomic (g)DNA content through hybridization with human gDNA baits, and capture-enrichment using gDNA derived from P. falciparum Plasmodium mitochondrial genome sequences were subsequently reconstructed from the resulting data. Phylogenetic analysis of the eradicated European P. vivax mtDNA genome indicates that the European isolate is closely related to the most common present-day American haplotype and likely entered the American continent post-Columbian contact. Furthermore, the European P. falciparum mtDNA indicates a link with current Indian strains that is in agreement with historical accounts.
García-Cruz, E E; Rodríguez-Ramírez, J; Méndez Lagunas, L L; Medina-Torres, L
2013-01-02
This study examines the rheological behavior of reconstituted spray-dried mucilage isolated from the cladodes of pitahaya (Hylocereus undatus), the effects of concentration and its relationship with physical properties were analyzed in reconstituted solutions. Drying process optimization was carried out through the surface response method, utilizing a factorial 2(3) design with three central points, in order to evaluate yield and rheological properties. The reconstituted mucilage exhibited non-Newtonian shear-thinning behavior, which adequately fit the Cross model (R(2)>0.95). This dynamic response suggests a random coil configuration. The steady-shear viscosity and dynamic response are suitably correlated through the Cox-Merz rule, confirming the mucilage's stability of flow. Analysis of the physical properties of the mucilage (Tg, DTP, and particle morphology) explains the shear-thinning behavior. Copyright © 2012 Elsevier Ltd. All rights reserved.