Sample records for duct application image

  1. Automated Breast Ultrasound for Ductal Pattern Reconstruction: Ground Truth File Generation and CADe Evaluation

    NASA Astrophysics Data System (ADS)

    Manousaki, D.; Panagiotopoulou, A.; Bizimi, V.; Haynes, M. S.; Love, S.; Kallergi, M.

    2017-11-01

    The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia™ Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert’s GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert’s but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.

  2. Potential application of in vivo imaging of impaired lymphatic duct to evaluate the severity of pressure ulcer in mouse model

    NASA Astrophysics Data System (ADS)

    Kasuya, Akira; Sakabe, Jun-Ichi; Tokura, Yoshiki

    2014-02-01

    Ischemia-reperfusion (IR) injury is a cause of pressure ulcer. However, a mechanism underlying the IR injury-induced lymphatic vessel damage remains unclear. We investigated the alterations of structure and function of lymphatic ducts in a mouse cutaneous IR model. And we suggested a new method for evaluating the severity of pressure ulcer. Immunohistochemistry showed that lymphatic ducts were totally vanished by IR injury, while blood vessels were relatively preserved. The production of harmful reactive oxygen species (ROS) was increased in injured tissue. In vitro study showed a high vulnerability of lymphatic endothelial cells to ROS. Then we evaluated the impaired lymphatic drainage using an in vivo imaging system for intradermally injected indocyanine green (ICG). The dysfunction of ICG drainage positively correlated with the severity of subsequent cutaneous changes. Quantification of the lymphatic duct dysfunction by this imaging system could be a useful strategy to estimate the severity of pressure ulcer.

  3. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    NASA Astrophysics Data System (ADS)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  4. Acoustic imaging of a duct spinning mode by the use of an in-duct circular microphone array.

    PubMed

    Wei, Qingkai; Huang, Xun; Peers, Edward

    2013-06-01

    An imaging method of acoustic spinning modes propagating within a circular duct simply with surface pressure information is introduced in this paper. The proposed method is developed in a theoretical way and is demonstrated by a numerical simulation case. Nowadays, the measurements within a duct have to be conducted using in-duct microphone array, which is unable to provide information of complete acoustic solutions across the test section. The proposed method can estimate immeasurable information by forming a so-called observer. The fundamental idea behind the testing method was originally developed in control theory for ordinary differential equations. Spinning mode propagation, however, is formulated in partial differential equations. A finite difference technique is used to reduce the associated partial differential equations to a classical form in control. The observer method can thereafter be applied straightforwardly. The algorithm is recursive and, thus, could be operated in real-time. A numerical simulation for a straight circular duct is conducted. The acoustic solutions on the test section can be reconstructed with good agreement to analytical solutions. The results suggest the potential and applications of the proposed method.

  5. Percutaneous transhepatic biliary drainage assisted by real-time virtual sonography: a retrospective study

    PubMed Central

    2013-01-01

    Background Real-time virtual sonography (RVS) is a diagnostic imaging support system that can synchronize with ultrasound images in conjunction with computed tomography or magnetic resonance images using magnetic navigation system. RVS has been applied in clinical practice to perform such procedures as radiofrequency ablation and biopsy; however, the application of RVS for percutaneous transhepatic biliary drainage (PTBD) is rare. Methods Between 2007 and 2012, RVS-assisted PTBD was performed for 30 patients (19 males and 11 females; age range, 41 to 89 years; mean age, 66.9 years) with obstructive jaundice. The targeted bile duct was determined using the RVS system before the procedure. The intervention was considered to be successful when the targeted bile duct was punctured and the drainage catheter was placed in the bile duct. Complications were evaluated according to the Society of Interventional Radiology Clinical Practice Guidelines. Results A total of 37 interventions were performed for 30 patients. The interventions were successful in 35 (95%) of 37 interventions. The targeted bile ducts were: B3 (n = 24), B5 (n = 7), B8 (n = 3), B6 (n = 1), and the anterior (n = 1) and posterior (n = 1) branches of the right bile duct. The mean targeted bile duct diameter was 4.9 mm (1.9 to 8.2 mm). PTBD was able to be accomplished in all patients because the non-targeted bile ducts were successfully punctured alternatively. No major complications were observed in relation to the interventional procedure. Conclusions RVS-assisted PTBD is a feasible and safe procedure. Accurate puncture of targeted bile ducts can be achieved using this method. PMID:23941632

  6. Müllerian duct cyst: diagnosis with MR imaging.

    PubMed

    Thurnher, S; Hricak, H; Tanagho, E A

    1988-07-01

    The value of magnetic resonance (MR) imaging in diagnosing clinically suspected müllerian duct cysts was assessed in six patients. MR imaging correctly demonstrated the abnormality to be intraprostatic, consistent with the diagnosis of müllerian duct cysts in four patients, and allowed the diagnosis to be excluded in the other two. The demonstration of prostatic zonal anatomy, the ability to obtain direct images in all three orthogonal planes, and a large field of view make MR imaging valuable in the study of suspected müllerian duct cysts.

  7. One-stop shop for 3-dimensional anatomy of hepatic vasculature and bile duct with special reference to biliary image reconstruction.

    PubMed

    Enkhbold, Ch; Shimada, M; Utsunomiya, T; Ishibashi, H; Yamada, S; Kanamoto, M; Arakawa, Y; Ikemoto, Z; Morine, E; Imura, S

    2013-01-01

    Three-dimensional CT has become an essential tool for successful hepatic surgery. Up to now, efforts have been made to simultaneously visualize hepatic vasculature and bile ducts. Herein, we introduce a new one-stop shop approach to hepatic 3D-anatomy, using a standard enhanced MDCT alone. A 3D-reconstruction of hepatic vasculature was made using data from contrast enhanced MDCT and SYNAPSE VINCENT software. We identified bile ducts from axial 2D image, and then reconstructed the 3D image. Both hepatic vasculature and bile duct images were integrated into a single image and it was compared with the 3D image, utilized with MRCP or DIC-CT. The first branches of both the right and left hepatic ducts were hand-traced and visualized for all 100 cases. The second branches of these ducts were visualized in 69 cases, and only the right second branch was recognized in 52 cases. Anomalous variations of bile ducts, such as posterior branch joining into common hepatic duct, were recognized in 12 cases. These biliary tract variations were all confirmed by MRCP or DIC-CT. Our new one-stop shop approach using the 3D imaging technique might contribute to successful hepatectomy as well as reduce medical costs and radiation exposure by omission of MRCP and DIC-CT.

  8. Magnetic resonance cholangiopancreatography (MRCP) using new negative per-oral contrast agent based on superparamagnetic iron oxide nanoparticles for extrahepatic biliary duct visualization in liver cirrhosis.

    PubMed

    Polakova, Katerina; Mocikova, Ingrid; Purova, Dana; Tucek, Pavel; Novak, Pavel; Novotna, Katerina; Izak, Niko; Bielik, Radoslav; Zboril, Radek; Miroslav, Herman

    2016-12-01

    Magnetic resonance cholangiopancreatography (MRCP) is often used for imaging of the biliary tree and is required by surgeons before liver transplantation. Advanced liver cirrhosis and ascites in patients however present diagnostic problems for MRCP. The aim of this study was to find out if the use of our negative per-oral contrast agent containing superparamagnetic iron oxide nanoparticles (SPIO) in MRCP is helpful for imaging of hepatobiliary tree in patients with liver cirrhosis. Forty patients with liver cirrhosis were examined on a 1.5 T MR unit using standard MRCP protocol. Twenty patients (group A) underwent MRCP after administration of per-oral SPIO contrast agent 30 min before examination. In group B, twenty patients were examined without per-oral bowel preparation. Ascites was present in eleven patients from group A and in thirteen patients in group B. Four radiologists analyzed MR images for visibility and delineation of the biliary tree. χ 2 tests were used for comparison of the visibility of intrahepatic and extrahepatic biliary ducts in patients with and without ascites. Better extrahepatic biliary duct visualization and visibility of extraluminal pathologies in patients with ascites was proved after administration of SPIO contrast agent. No statistically significant difference between group A and B was found for visualization of extrahepatic biliary ducts in patients without ascites. Delineation of intrahepatic biliary ducts was independent on bowel preparation. Application of our negative per-oral SPIO contrast agent before MRCP improves the visualization of extrahepatic biliary ducts in patients with ascites which is helpful during the liver surgery, mainly in liver transplantation.

  9. Characterization of the biliary tract by virtual ultrasonography constructed by gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging.

    PubMed

    Koizumi, Yohei; Hirooka, Masashi; Ochi, Hironori; Tokumoto, Yoshio; Takechi, Megumi; Hiraoka, Atsushi; Ikeda, Yoshio; Kumagi, Teru; Matsuura, Bunzo; Abe, Masanori; Hiasa, Yoichi

    2015-04-01

    This study aimed at prospectively evaluating bile duct anatomy on ultrasonography and evaluating the safety and utility of radiofrequency ablation (RFA) assisted by virtual ultrasonography from gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). The institutional review board approved this study, and patients provided written informed consent prior to entry into the study. Bile duct anatomy was assessed in 201 patients who underwent Gd-EOB-DTPA-enhanced MRI for the evaluation of hepatic tumor. Eighty-one of these patients subsequently underwent RFA assisted by ultrasound imaging. In 23 patients, the tumor was located within 5 mm of the central bile duct, as demonstrated by MRI. Virtual ultrasonography constructed by Gd-EOB-enhanced MRI was able to visualize the common bile duct, left hepatic duct, and right hepatic duct in 96.5, 94.0, and 89.6 % of cases, respectively. The target hepatic tumor nodule and biliary duct could be detected with virtual ultrasonography in all patients, and no severe complications occurred. The running pattern of the bile ducts could be recognized on conventional ultrasound by referencing virtual ultrasonography constructed by Gd-EOB-DTPA-enhanced MRI. RFA assisted by this imaging strategy did not result in bile duct injury.

  10. Intraductal biliopancreatic imaging: European Society of Gastrointestinal Endoscopy (ESGE) technology review.

    PubMed

    Tringali, Andrea; Lemmers, Arnaud; Meves, Volker; Terheggen, Grischa; Pohl, Jürgen; Manfredi, Guido; Häfner, Michael; Costamagna, Guido; Devière, Jacques; Neuhaus, Horst; Caillol, Fabrice; Giovannini, Marc; Hassan, Cesare; Dumonceau, Jean-Marc

    2015-08-01

    This technology review expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) on the available techniques for intraductal biliopancreatic imaging. The three cholangioscopy techniques are described: the "dual-operator" and " single-operator" mother-baby approaches using dedicated instruments, and the "direct" technique using currently available ultrathin gastroscopes. The mother-baby method is standardized and reproducible, while direct cholangioscopy is technically demanding and its safety requires further evaluation. As well as direct visualization of the bile ducts, cholangioscopy has the further advantage of allowing targeted biopsy. Image quality is still suboptimal for single-operator cholangioscopy, while the other techniques have achieved adequately detailed imaging. The costs of mother-baby cholangioscopy are high and its application in clinical practice should be restricted to selected cases (i.e. indeterminate biliary strictures/intraluminal lesions, difficult biliary stones) and to the setting of tertiary care centers. Peroral pancreatoscopy may find an indication in situations where other imaging modalities (mainly EUS) are inconclusive (i.e. delineation of main duct intraductal papillary mucinous neoplasia extension, sampling of indeterminate main pancreatic duct strictures). Intraductal ultrasonography (IDUS) has a poorer performance than EUS in the staging of pancreatic malignancies and can increase the risk of pancreatitis. A promising indication for IDUS could be the evaluation of indeterminate biliary strictures and ampullary tumors. Probe-based confocal laser endomicroscopy (pCLE) of the bile ducts is a difficult and expensive technique. Appropriate training needs to be established, since interpretation of images is challenging. pCLE can be an important diagnostic tool in the setting of indeterminate biliary strictures. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Recent advances in cardiac catheterization for congenital heart disease

    PubMed Central

    Kang, Sok-Leng; Benson, Lee

    2018-01-01

    The field of pediatric and adult congenital cardiac catheterization has evolved rapidly in recent years. This review will focus on some of the newer endovascular technological and management strategies now being applied in the pediatric interventional laboratory. Emerging imaging techniques such as three-dimensional (3D) rotational angiography, multi-modal image fusion, 3D printing, and holographic imaging have the potential to enhance our understanding of complex congenital heart lesions for diagnostic or interventional purposes. While fluoroscopy and standard angiography remain procedural cornerstones, improved equipment design has allowed for effective radiation exposure reduction strategies. Innovations in device design and implantation techniques have enabled the application of percutaneous therapies in a wider range of patients, especially those with prohibitive surgical risk. For example, there is growing experience in transcatheter duct occlusion in symptomatic low-weight or premature infants and stent implantation into the right ventricular outflow tract or arterial duct in cyanotic neonates with duct-dependent pulmonary circulations. The application of percutaneous pulmonary valve implantation has been extended to a broader patient population with dysfunctional ‘native’ right ventricular outflow tracts and has spurred the development of novel techniques and devices to solve associated anatomic challenges. Finally, hybrid strategies, combining cardiosurgical and interventional approaches, have enhanced our capabilities to provide care for those with the most complex of lesions while optimizing efficacy and safety. PMID:29636905

  12. [Clinical value of MRI united-sequences examination in diagnosis and differentiation of morphological sub-type of hilar and extrahepatic big bile duct cholangiocarcinoma].

    PubMed

    Yin, Long-Lin; Song, Bin; Guan, Ying; Li, Ying-Chun; Chen, Guang-Wen; Zhao, Li-Ming; Lai, Li

    2014-09-01

    To investigate MRI features and associated histological and pathological changes of hilar and extrahepatic big bile duct cholangiocarcinoma with different morphological sub-types, and its value in differentiating between nodular cholangiocarcinoma (NCC) and intraductal growing cholangiocarcinoma (IDCC). Imaging data of 152 patients with pathologically confirmed hilar and extrahepatic big bile duct cholangiocarcinoma were reviewed, which included 86 periductal infiltrating cholangiocarcinoma (PDCC), 55 NCC, and 11 IDCC. Imaging features of the three morphological sub-types were compared. Each of the subtypes demonstrated its unique imaging features. Significant differences (P < 0.05) were found between NCC and IDCC in tumor shape, dynamic enhanced pattern, enhancement degree during equilibrium phase, multiplicity or singleness of tumor, changes in wall and lumen of bile duct at the tumor-bearing segment, dilatation of tumor upstream or downstream bile duct, and invasion of adjacent organs. Imaging features reveal tumor growth patterns of hilar and extrahepatic big bile duct cholangiocarcinoma. MRI united-sequences examination can accurately describe those imaging features for differentiation diagnosis.

  13. Computer analysis of three-dimensional morphological characteristics of the bile duct

    NASA Astrophysics Data System (ADS)

    Ma, Jinyuan; Chen, Houjin; Peng, Yahui; Shang, Hua

    2017-01-01

    In this paper, a computer image-processing algorithm for analyzing the morphological characteristics of bile ducts in Magnetic Resonance Cholangiopancreatography (MRCP) images was proposed. The algorithm consisted of mathematical morphology methods including erosion, closing and skeletonization, and a spline curve fitting method to obtain the length and curvature of the center line of the bile duct. Of 10 cases, the average length of the bile duct was 14.56 cm. The maximum curvature was in the range of 0.111 2.339. These experimental results show that using the computer image-processing algorithm to assess the morphological characteristics of the bile duct is feasible and further research is needed to evaluate its potential clinical values.

  14. Bile duct hamartomas (von Mayenburg complexes) mimicking liver metastases from bile duct cancer: MRC findings

    PubMed Central

    Nagano, Yasuhiko; Matsuo, Kenichi; Gorai, Katsuya; Sugimori, Kazuya; Kunisaki, Chikara; Ike, Hideyuki; Tanaka, Katsuaki; Imada, Toshio; Shimada, Hiroshi

    2006-01-01

    We present a case of a 72-year-old man with a common bile duct cancer, who was initially believed to have multiple liver metastases based on computed tomography findings, and in whom magnetic resonance cholangiography (MRC) revealed a diagnosis of bile duct hamartomas. At exploration for pancreaticoduodenectomy, liver palpation revealed disseminated nodules at the surface of the liver. These nodules showed gray-white nodular lesions of about 0.5 cm in diameter scattered on the surface of both liver lobes, which were looked like multiple liver metastases from bile duct cancer. Frozen section of the liver biopsy disclosed multiple bile ducts with slightly dilated lumens embedded in the collagenous stroma characteristics of multiple bile duct hamartomas (BDHs). Only two reports have described the MRC features of bile duct hamartomas. Of all imaging procedures, MRC provides the most relevant features for the imaging diagnosis of bile duct hamartomas. PMID:16534895

  15. Enhanced visualization of the bile duct via parallel white light and indocyanine green fluorescence laparoscopic imaging

    NASA Astrophysics Data System (ADS)

    Demos, Stavros G.; Urayama, Shiro

    2014-03-01

    Despite best efforts, bile duct injury during laparoscopic cholecystectomy is a major potential complication. Precise detection method of extrahepatic bile duct during laparoscopic procedures would minimize the risk of injury. Towards this goal, we have developed a compact imaging instrumentation designed to enable simultaneous acquisition of conventional white color and NIR fluorescence endoscopic/laparoscopic imaging using ICG as contrast agent. The capabilities of this system, which offers optimized sensitivity and functionality, are demonstrated for the detection of the bile duct in an animal model. This design could also provide a low-cost real-time surgical navigation capability to enhance the efficacy of a variety of other image-guided minimally invasive procedures.

  16. Accuracy of percutaneous transhepatic cholangiography in predicting the location and nature of major bile duct injuries.

    PubMed

    Fidelman, Nicholas; Kerlan, Robert K; Laberge, Jeanne M; Gordon, Roy L

    2011-06-01

    To determine the ability of percutaneous transhepatic cholangiography (PTC) to predict accurately the anatomic location and nature of major bile duct injuries, to examine the contribution of endoscopic retrograde cholangiopancreatography (ERCP) and PTC to the diagnosis of injuries to the low-inserting right posterior segmental ducts, and to compare the ability of radiologists and gastroenterologists to detect injuries to the low-inserting right posterior segmental duct. PTC images and operative reports of 78 consecutive patients who underwent surgical repair of major bile duct injuries at the authors' institution were retrospectively reviewed. The location of injury was assessed according to the Bismuth classification. Images were also evaluated for the presence of a biliary stricture, biliary leak, or both. Imaging observations were compared with findings obtained during surgical biliary reconstruction. PTC correctly predicted the anatomic location of injuries in 85% of patients. Incorrect Bismuth type was assigned in 12 patients. Seven of the errors (58%) originated from the inability to distinguish injuries at the confluence of the lobar ducts from injuries involving the cephalad 2 cm of the common hepatic duct. Injuries to the right posterior segmental duct were detected more often on ERCP images by gastroenterologists than by diagnostic radiologists. In four patients (5%), biliary strictures were masked on PTC by the presence of a concomitant leak. PTC accurately depicts the location and nature of major bile duct injuries in most patients. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  17. Use of magnetic resonance cholangiography in the diagnosis of choledocholithiasis: prospective comparison with a reference imaging method

    PubMed Central

    Zidi, S; Prat, F; Le Guen, O; Rondeau, Y; Rocher, L; Fritsch, J; Choury, A; Pelletier, G

    1999-01-01

    Background—Magnetic resonance cholangiography (MRC) is a new technique for non-invasive imaging of the biliary tract. 
Aim—To assess the results of MRC in patients with suspected bile duct stones as compared with those obtained with reference imaging methods. 
Patients/Methods—70 patients (34 men and 36 women, mean (SD) age 71 (15.5) years; median 75) with suspected bile duct stones were included (cholangitis, 33; pancreatitis, three; suspected post-cholecystectomy choledocholithiasis, nine; cholestasis, six; stones suspected on ultrasound or computed tomography scan, 19). MR cholangiograms with two dimensional turbo spin echo sequences were acquired. Endoscopic retrograde cholangiography with or without sphincterotomy (n = 63), endosonography (n = 5), or intraoperative cho- langiography (n = 2) were the reference imaging techniques used for the study and were performed within 12 hours of MRC. Radiologists were blinded to the results of endoscopic retrograde cholangiography and previous investigations. 
Results—49 patients (70%) had bile duct stones on reference imaging (common bile duct, 44, six of which impacted in the papilla; intrahepatic, four; cystic duct stump, one). Stone size ranged from 1 to 20 mm (mean 6.1, median 5.5). Twenty seven patients (55%) had bile duct stones smaller than 6 mm. MRC diagnostic accuracy for bile duct lithiasis was: sensitivity, 57.1%; specificity, 100%; positive predictive value, 100%; negative predictive value, 50%. 
Conclusions—Stones smaller than 6 mm are still often missed by MRC when standard equipment is used. The general introduction of new technical improvements is needed before this method can be considered reliable for the diagnosis of bile duct stones. 

 Keywords: bile duct calculi; endoscopic retrograde cholangiography; magnetic resonance cholangiography PMID:9862837

  18. Heterogeneity Between Ducts of the Same Nuclear Grade Involved by Duct Carcinoma In Situ (DCIS) of the Breast

    PubMed Central

    Miller, Naomi A.; Chapman, Judith-Anne W.; Qian, Jin; Christens-Barry, William A.; Fu, Yuejiao; Yuan, Yan; Lickley, H. Lavina A.; Axelrod, David E.

    2010-01-01

    Purpose Nuclear grade of breast DCIS is considered during patient management decision-making although it may have only a modest prognostic association with therapeutic outcome. We hypothesized that visual inspection may miss substantive differences in nuclei classified as having the same nuclear grade. To test this hypothesis, we measured subvisual nuclear features by quantitative image cytometry for nuclei with the same grade, and tested for statistical differences in these features. Experimental design and statistical analysis Thirty-nine nuclear digital image features of about 100 nuclei were measured in digital images of H&E stained slides of 81 breast biopsy specimens. One field with at least 5 ducts was evaluated for each patient. We compared features of nuclei with the same grade in multiple ducts of the same patient with ANOVA (or Welch test), and compared features of nuclei with the same grade in two ducts of different patients using 2-sided t-tests (P ≤ 0.05). Also, we compared image features for nuclei in patients with single grade to those with the same grade in patients with multiple grades using t-tests. Results Statistically significant differences were detected in nuclear features between ducts with the same nuclear grade, both in different ducts of the same patient, and between ducts in different patients with DCIS of more than one grade. Conclusion Nuclei in ducts visually described as having the same nuclear grade had significantly different subvisual digital image features. These subvisual differences may be considered additional manifestations of heterogeneity over and above differences that can be observed microscopically. This heterogeneity may explain the inconsistency of nuclear grading as a prognostic factor. PMID:20981137

  19. [Value of MR imaging in the diagnosis of intraductal papillary neoplasm of the bile duct].

    PubMed

    Song, Fengxiang; Zhou, Jun; Shi, Yuxin; Zeng, Mengsu; Zhou, Kangrong; Ding, Yuqin; Cao, Yingli; Zhou, Jianjun

    2015-01-01

    To analyze the value of MR imaging in diagnosis of intraductal papillary neoplasm of the bile duct (IPN-B). Fourteen patients with intraductal papillary neoplasms of the bile duct confirmed by surgical pathology were included in this study. The patients underwent MR routine plain scanning and enhancement scanning (including T1WI, T2WI with fat suppression, FALSH T1WI, and three-phase enhancement scanning), diffusion weighted imaging(DWI) and magnetic resonance cholangiopancreatography (MRCP) before operation. The imaging data were reviewed and analyzed retrospectively in comparison with the surgical and pathological results. In these patients, 7 cases had tumors located in the left lobe, 2 cases had tumors in both the left and right lobes, 2 cases in the hepatic hilum, 2 cases in the common bile duct, and 1 case in both the right lobe and the common bile duct. Solitary or multiple intraductal masses could be found in 12 cases, with 11 cases appeared as papillary masses and one case as flat mass. In the other two cases the tumor was not visible (one case had too many stones, and in another case the tumor was too small). The tumors in the 12 cases showed hypointensity on T1WI and hyperintensity on T2WI. On the dynamic contrast-enhanced MRI, 11 cases showed mild and one showed moderate enhancement in arterial phase, and all the cases showed mildly and gradually delayed enhancement. On DWI, the lesion areas showed high signal intensity in all the cases, and the ADC value of the tumor area (1.697×10(-3)mm(2)/s) was significantly lower than that of the normal bile (3.973×10(-3)mm(2)/s) (t = -10.94, P < 0.05). Twelve cases demonstrated filling defects on primary MRCP coronary thin section images. On 3D-reconstruction MRCP images, 7 cases exhibited diffuse bile duct dilatation with the tumor areas more prominent, 3 cases exhibited aneurysmal bile dilatation, while the rest 4 cases exhibited segmental or lobar bile duct dilatation ( including 2 with invisible tumors ). In the 3 cases with aneurysmal bile dilatation, the multiple directions of MRCP images helped to find the communication between the aneurysmal dilatation and the bile duct. All the cases showed significant proximal bile duct dilatation (the extent of dilatation >100%), and 9 cases also showed distal bile duct dilatation. Bile duct stones were noted in 6 cases, 4 at the tumor area, and the other 2 away from the tumor area. No adjacent tissue invasion and no distal tissue or lymph node metastasis were observed. Intraductal papillary neoplasms of the bile ducts have characteristic imaging appearances on MRI, and MRI is an important method helpful to making correct diagnosis.

  20. Low-Cost Flow Visualization for a Supersonic Ejector

    NASA Technical Reports Server (NTRS)

    Olden, George W.; Lineberry, David M.; Linn, Christopher A. B.; Landrum, Brian D.; Hawk, Clark W.

    2005-01-01

    Shadowgraph techniques were applied to the cold flow ejector facility at the Propulsion Research Center at the University of Alabama in Huntsville. The setup for the experiments was relatively simple and was accomplished at very little cost. Series of shadowgraph images were taken of both dual nozzle and single nozzle strut based ejectors operating over a range of chamber pressures. The density gradient patterns in the shadowgraphs were compared to pressure data measured along the top and side walls of the mixing duct. The shadowgraph images showed the presence of barrel shocks emanating from the nozzles which at low pressures terminated in Mach disks and at higher pressures extended beyond the barrel shape and reflected off the walls of the duct. Based on pressure data from previous testing, reflected shocks were expected on the walls of the duct. The shadowgraph images confirmed the locations of these reflected shocks on the top wall of the duct. The shadowgraph images also showed the structure change which correlated to a change in pitch of the ejector noise, and corresponded to a change in trend of the duct wall pressure ratio distributions. The images produced from the setup provided insight into the complex flow behavior inside the ejector duct. In addition, the techniques were a valuable tool as an educational device for students.

  1. Biliary tract enhancement in gadoxetic acid-enhanced MRI correlates with liver function biomarkers.

    PubMed

    Noda, Yoshifumi; Goshima, Satoshi; Kajita, Kimihiro; Kawada, Hiroshi; Kawai, Nobuyuki; Koyasu, Hiromi; Matsuo, Masayuki; Bae, Kyongtae T

    2016-11-01

    To evaluate the association between gadoxetic-acid-enhanced magnetic resonance (MR) imaging measurements and laboratory and clinical biomarkers of liver function and fibrosis. One hundred thirty nine consecutive patients with suspected liver disease or liver tumor underwent gadoxetic-acid-enhanced MR imaging. MR imaging measurements during the hepatobiliary phase included biliary tract structure-to-muscle signal intensity ratio (SIR). These measurements were compared with Child-Pugh classification, end-stage liver disease (MELD) score, and aspartate aminotransferase-to-platelet ratio index (APRI). The SIRs of cystic duct and common bile duct were significantly correlated with Child-Pugh classification (P=0.012 for cystic duct and P<0.0001 for common bile duct), MELD score (P=0.0016 and P=0.0033), and APRI (P=0.0022 and P=0.0015). The sensitivity, specificity, and area under the receiver-operating-characteristic curve were: (74%, 88%, 0.86) with the SIR of common bile duct for the detection of patients with Child-Pugh class B or C; (100%, 87%, 0.94) with the SIR of cystic duct for MELD score (>10); (65%, 76%, 0.70) with the SIR of common bile duct for APRI (>1.5). Gadoxetic-acid contrast enhancement of cystic duct and common bile duct could be used as biomarkers to assess liver function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Volumetric laser endomicroscopy in the biliary and pancreatic ducts: a feasibility study with histological correlation.

    PubMed

    Corral, Juan E; Mousa, Omar Y; Krishna, Murli; Levink, Iris J M; Pursell, Khela R; Afsh, Mohammad; Kröner, Paul T; Harnois, Denise M; Wolfsen, Herbert C; Wallace, Michael B; Lukens, Frank J

    2018-06-18

     Volumetric laser endomicroscopy (VLE) provides circumferential images 3 mm into the biliary and pancreatic ducts. We aimed to correlate VLE images with the normal and abnormal microstructure of these ducts. Samples from patients undergoing hepatic or pancreatic resection were evaluated. VLE images were collected using a low-profile VLE catheter inserted manually into the biliary and pancreatic ducts ex vivo. Histological correlation was assessed by two unblinded investigators.  25 patients (20 liver and 5 pancreatic samples) and 111 images were analyzed. VLE revealed three histological layers: epithelium, connective tissue, and parenchyma. It identified distinctive patterns for primary sclerosing cholangitis (PSC), pancreatic cysts, neuroendocrine tumor, and adenocarcinoma adjacent to the pancreatic duct or ampulla. VLE failed to identify dysplasia in a dominant stricture and inflammatory infiltrates in PSC. Reflectivity measurements of the liver parenchyma diagnosed liver cirrhosis with high sensitivity.  VLE can identify histological changes in the biliary and pancreatic ducts allowing real-time diagnosis. Further studies are needed to measure the accuracy of VLE in a larger sample and to validate our findings in vivo. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Proposal of a novel method for observing the breast by high-resolution ultrasound imaging: understanding the normal breast structure and its application in an observational method for detecting deviations.

    PubMed

    Izumori, Ayumi; Horii, Rie; Akiyama, Futoshi; Iwase, Takuji

    2013-01-01

    With the recent advances in modalities for diagnostic imaging of the breast, it is now essential to detect isoechoic masses and small nonmass lesions, to which little attention has so far been paid using ultrasound (US) of the breast. It will be possible with the observation method to understand normal breast structural images and anatomy. We elucidated the detailed histological architecture of the normal breast, information indispensable for diagnostic US of the breast. Verification of the above hypotheses was carried out using the breasts of 11 patients who underwent total mastectomy at our clinic. Isoechoic structures with fat are lobules, all ducts, and surrounding stroma that support the ducts; intervening hyperechoic areas are edematous stroma and fat-containing stroma that support the breast. By taking an isoechoic structure that reflects the course of the ducts as the basic structure for observation, the boundary between the lobes can be inferred. Detection of deviations from the normal structure using the method for interpreting three-dimensional ultrasound images of mammary lobes is a radical new approach for diagnosing breast cancer. This technique is very simple and amenable to standardization once one understands the underlying theory. Furthermore, it is useful as a screening method as well as for easy detection of faint minute lesions that can only be detected by magnetic resonance imaging or second-look targeted US.

  4. Positive predictive value of cholescintigraphy in common bile duct obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.

    1986-09-01

    Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presencemore » of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct.« less

  5. MRI ductography of contrast agent distribution and leakage in normal mouse mammary ducts and ducts with in situ cancer.

    PubMed

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S

    2017-07-01

    High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (p<0.001) than in non-cancerous FVB/N mouse mammary ducts, perhaps due to rapid washout of contrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Combined use of videoendoscopy and X-ray imaging for improved monitoring of stenting application

    NASA Astrophysics Data System (ADS)

    Cysewska-Sobusiak, A. R.; Sowier, A.; Skrzywanek, P.

    2005-09-01

    The subject of this paper concerns advanced techniques of procedures and imaging used in minimally invasive surgery and in non-operable cases of the alimentary tract tumor therapy. Examples of videoendoscopy and X-ray imaging used for the application of stents (prostheses) and catheters allowing for the performance of diagnostic and endo-therapeutic procedures are described. The possibility was indicated to elaborate a new method of proceeding in tumor therapy in the patients for whom the methods used so far were ineffective. In the paper examples of combined imaging the application of metallic stents and plastic catheters allowing for the performance of diagnostic and therapeutic procedures are presented. The cases shown refer to tumor located in the esophagus and in the bile and pancreatic ducts.

  7. Bile Duct Cancer

    MedlinePlus

    ... the liver get rid of toxins and wastes. Bile duct cancer is rare. It can happen in the parts ... Itchy skin Fever Abdominal pain Tests to diagnose bile duct cancer may include a physical exam, imaging tests of ...

  8. Choledochoscopic Examination of a 3-Dimensional Printing Model Using Augmented Reality Techniques: A Preliminary Proof of Concept Study.

    PubMed

    Tang, Rui; Ma, Longfei; Li, Ang; Yu, Lihan; Rong, Zhixia; Zhang, Xinjing; Xiang, Canhong; Liao, Hongen; Dong, Jiahong

    2018-06-01

    We applied augmented reality (AR) techniques to flexible choledochoscopy examinations. Enhanced computed tomography data of a patient with intrahepatic and extrahepatic biliary duct dilatation were collected to generate a hollow, 3-dimensional (3D) model of the biliary tree by 3D printing. The 3D printed model was placed in an opaque box. An electromagnetic (EM) sensor was internally installed in the choledochoscope instrument channel for tracking its movements through the passages of the 3D printed model, and an AR navigation platform was built using image overlay display. The porta hepatis was used as the reference marker with rigid image registration. The trajectories of the choledochoscope and the EM sensor were observed and recorded using the operator interface of the choledochoscope. Training choledochoscopy was performed on the 3D printed model. The choledochoscope was guided into the left and right hepatic ducts, the right anterior hepatic duct, the bile ducts of segment 8, the hepatic duct in subsegment 8, the right posterior hepatic duct, and the left and the right bile ducts of the caudate lobe. Although stability in tracking was less than ideal, the virtual choledochoscope images and EM sensor tracking were effective for navigation. AR techniques can be used to assist navigation in choledochoscopy examinations in bile duct models. Further research is needed to determine its benefits in clinical settings.

  9. Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing.

    PubMed

    Kwon, Heejin; Reid, Scott; Kim, Dongeun; Lee, Sangyun; Cho, Jinhan; Oh, Jongyeong

    2018-01-04

    This study aimed to evaluate image quality and diagnostic performance of a recently developed navigated three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with compressed sensing (CS) based on parallel imaging (PI) and conventional 3D-MRCP with PI only in patients with abnormal bile duct dilatation. This institutional review board-approved study included 45 consecutive patients [non-malignant common bile duct lesions (n = 21) and malignant common bile duct lesions (n = 24)] who underwent MRCP of the abdomen to evaluate bile duct dilatation. All patients were imaged at 3T (MR 750, GE Healthcare, Waukesha, WI) including two kinds of 3D-MRCP using 352 × 288 matrices with and without CS based on PI. Two radiologists independently and blindly assessed randomized images. CS acceleration reduced the acquisition time on average 5 min and 6 s to a total of 2 min and 56 s. The all CS cine image quality was significantly higher than standard cine MR image for all quantitative measurements. Diagnostic accuracy for benign and malignant lesions is statistically different between standard and CS 3D-MRCP. Total image quality and diagnostic accuracy at biliary obstruction evaluation demonstrates that CS-accelerated 3D-MRCP sequences can provide superior quality of diagnostic information in 42.5% less time. This has the potential to reduce motion-related artifacts and improve diagnostic efficacy.

  10. Passive OCT probe head for 3D duct inspection

    NASA Astrophysics Data System (ADS)

    Ford, Helen D.; Tatam, Ralph P.

    2013-09-01

    A passive, endoscopic optical coherence tomography (OCT) probe has been demonstrated, incorporating an imaging fibre bundle and 45° conical mirror, and with no electromechanical components at the probe tip. Circular scanning, of the beam projected onto the proximal face of the imaging bundle, produces a corresponding circular scan at the distal end of the bundle. The beam is turned through 90° by the conical mirror and converted into a radially-scanned sample beam, permitting circumferential OCT scanning in quasi-cylindrical ducts. OCT images, displayed as polar plots and as 3D reconstructions, are presented, showing the internal profile of a metallic test sample containing a 660 µm step in the internal wall. Results have been acquired using two methods: one that makes use of multiple beam-circle diameters, and a mechanical ‘pull-back’ technique. The effects of the convex surface of the conical mirror on spatial resolution are discussed, with suggested working distances given for different application regimes.

  11. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms

    PubMed Central

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-01-01

    AIM: To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B). METHODS: The imaging findings of five cases of IPMN-B which were pathologically confirmed at our hospital between March 2012 and May 2013 were retrospectively analyzed. Three of these cases were diagnosed by duodenal endoscopy and biopsy pathology, and two cases were diagnosed by surgical pathology. All five patients underwent enhanced and non-enhanced computed tomography (CT), magnetic resonance cholangiopancreatography, and Gd-EOB-DTPA-enhanced MRI; one case underwent both Gd-EOB-DTPA-enhanced MRI and positron emission tomography-CT. The clinical data and imaging results for these cases were compared and are presented. RESULTS: Conventional imaging showed diffuse dilatation of bile ducts and multiple intraductal polypoid and papillary neoplasms or serrated changes along the bile ducts. In two cases, Gd-EOB-DTPA-enhanced MRI revealed dilated biliary ducts and intraductal tumors, as well as filling defects caused by mucin in the dilated bile ducts in the hepatobiliary phase. Gd-EOB-DTPA-enhanced MRI in one case clearly showed a low-signal tumor in the hepatobiliary phase, similar to what was seen by positron emission tomography-CT. In two patients, routine inspection was unable to discern whether the lesions were inflammation or tumors. However, Gd-EOB-DTPA-enhanced MRI revealed a pattern of gradual enhancement during the hepatobiliary phase, and the signal intensity of the lesions was lower than the surrounding liver parenchyma, suggesting tissue inflammation in both cases, which were confirmed by surgical pathology. CONCLUSION: Gd-EOB-DTPA-enhanced MRI reveals the intraductal mucin component of IPMN-B in some cases and the extent of tumor infiltration beyond the bile ducts in invasive cases. PMID:26167082

  12. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms.

    PubMed

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-07-07

    To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B). The imaging findings of five cases of IPMN-B which were pathologically confirmed at our hospital between March 2012 and May 2013 were retrospectively analyzed. Three of these cases were diagnosed by duodenal endoscopy and biopsy pathology, and two cases were diagnosed by surgical pathology. All five patients underwent enhanced and non-enhanced computed tomography (CT), magnetic resonance cholangiopancreatography, and Gd-EOB-DTPA-enhanced MRI; one case underwent both Gd-EOB-DTPA-enhanced MRI and positron emission tomography-CT. The clinical data and imaging results for these cases were compared and are presented. Conventional imaging showed diffuse dilatation of bile ducts and multiple intraductal polypoid and papillary neoplasms or serrated changes along the bile ducts. In two cases, Gd-EOB-DTPA-enhanced MRI revealed dilated biliary ducts and intraductal tumors, as well as filling defects caused by mucin in the dilated bile ducts in the hepatobiliary phase. Gd-EOB-DTPA-enhanced MRI in one case clearly showed a low-signal tumor in the hepatobiliary phase, similar to what was seen by positron emission tomography-CT. In two patients, routine inspection was unable to discern whether the lesions were inflammation or tumors. However, Gd-EOB-DTPA-enhanced MRI revealed a pattern of gradual enhancement during the hepatobiliary phase, and the signal intensity of the lesions was lower than the surrounding liver parenchyma, suggesting tissue inflammation in both cases, which were confirmed by surgical pathology. Gd-EOB-DTPA-enhanced MRI reveals the intraductal mucin component of IPMN-B in some cases and the extent of tumor infiltration beyond the bile ducts in invasive cases.

  13. In vivo multiphoton imaging of bile duct ligation

    NASA Astrophysics Data System (ADS)

    Liu, Yuan; Li, Feng-Chieh; Chen, Hsiao-Chin; Chang, Po-shou; Yang, Shu-Mei; Lee, Hsuan-Shu; Dong, Chen-Yuan

    2008-02-01

    Bile is the exocrine secretion of liver and synthesized by hepatocytes. It is drained into duodenum for the function of digestion or drained into gallbladder for of storage. Bile duct obstruction is a blockage in the tubes that carry bile to the gallbladder and small intestine. However, Bile duct ligation results in the changes of bile acids in serum, liver, urine, and feces1, 2. In this work, we demonstrate a novel technique to image this pathological condition by using a newly developed in vivo imaging system, which includes multiphoton microscopy and intravital hepatic imaging chamber. The images we acquired demonstrate the uptake, processing of 6-CFDA in hepatocytes and excretion of CF in the bile canaliculi. In addition to imaging, we can also measure kinetics of the green fluorescence intensity.

  14. Image-guided intervention in the human bile duct using scanning fiber endoscope system

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.; Jo, Javier A.; Melville, C. David; Johnston, Richard S.; Naumann, Christopher R.; Saunders, Michael D.

    2012-01-01

    Bile duct cancers are increasing in frequency while being difficult to diagnose. Currently available endoscopic imaging devices used in the biliary tree are low resolution with poor image quality, leading to inadequate evaluation of indeterminate biliary strictures. However, a new ultrathin and flexible cholangioscope system has been successfully demonstrated in a human subject. This mini-cholangioscope system uses a scanning fiber endoscope (SFE) as a forward-imaging guidewire, dimensions of 1.2-mm diameter and 3-m length. Full color video (500-line resolution at 30Hz) is the standard SFE imaging mode using spiral scanning of red, green, and blue laser light at low power. Image-guided operation of the biopsy forceps was demonstrated in healthy human bile ducts with and without saline flushing. The laser-based video imaging can be switched to various modes to enhance tissue markers of disease, such as widefield fluorescence and enhanced spectral imaging. In parallel work, biochemical discrimination of tissue health in pig bile duct has been accomplished using fiberoptic delivery of pulsed UV illumination and time-resolved autofluorescence spectroscopic measurements. Implementation of time-resolved fluorescence spectroscopy for biochemical assessment of the bile duct wall is being done through a secondary endoscopic channel. Preliminary results indicate that adequate SNR levels (> 30 dB) can be achieved through a 50 micron fiber, which could serve as an optical biopsy probe. The SFE is an ideal mini-cholangioscope for integration of both tissue and molecular specific image contrast in the future. This will provide the physician with unprecedented abilities to target biopsy locations and perform endoscopically-guided therapies.

  15. Mammary duct ectasia: a cause of bloody nipple discharge.

    PubMed Central

    Leung, Alexander K. C.; Kao, C. Pion

    2004-01-01

    We report a 13-year-old girl with bloody nipple discharge as a result of mammary duct ectasia. Our patient is the second reported case of mammary duct ectasia in a pubertal girl. Images Figure 1 PMID:15101674

  16. Locating and Quantifying Broadband Fan Sources Using In-Duct Microphones

    NASA Technical Reports Server (NTRS)

    Dougherty, Robert P.; Walker, Bruce E.; Sutliff, Daniel L.

    2010-01-01

    In-duct beamforming techniques have been developed for locating broadband noise sources on a low-speed fan and quantifying the acoustic power in the inlet and aft fan ducts. The NASA Glenn Research Center's Advanced Noise Control Fan was used as a test bed. Several of the blades were modified to provide a broadband source to evaluate the efficacy of the in-duct beamforming technique. Phased arrays consisting of rings and line arrays of microphones were employed. For the imaging, the data were mathematically resampled in the frame of reference of the rotating fan. For both the imaging and power measurement steps, array steering vectors were computed using annular duct modal expansions, selected subsets of the cross spectral matrix elements were used, and the DAMAS and CLEAN-SC deconvolution algorithms were applied.

  17. Syntactic methods of shape feature description and its application in analysis of medical images

    NASA Astrophysics Data System (ADS)

    Ogiela, Marek R.; Tadeusiewicz, Ryszard

    2000-02-01

    The paper presents specialist algorithms of morphologic analysis of shapes of selected organs of abdominal cavity proposed in order to diagnose disease symptoms occurring in the main pancreatic ducts and upper segments of ureters. Analysis of the correct morphology of these structures has been conducted with the use of syntactic methods of pattern recognition. Its main objective is computer-aided support to early diagnosis of neoplastic lesions and pancreatitis based on images taken in the course of examination with the endoscopic retrograde cholangiopancreatography (ERCP) method and a diagnosis of morphological lesions in ureter based on kidney radiogram analysis. In the analysis of ERCP images, the main objective is to recognize morphological lesions in pancreas ducts characteristic for carcinoma and chronic pancreatitis. In the case of kidney radiogram analysis the aim is to diagnose local irregularity of ureter lumen. Diagnosing the above mentioned lesion has been conducted with the use of syntactic methods of pattern recognition, in particular the languages of shape features description and context-free attributed grammars. These methods allow to recognize and describe in a very efficient way the aforementioned lesions on images obtained as a result of initial image processing into diagrams of widths of the examined structures.

  18. Anatomy of the lactating human breast redefined with ultrasound imaging

    PubMed Central

    Ramsay, DT; Kent, JC; Hartmann, RA; Hartman, PE

    2005-01-01

    The aim of this study was to use ultrasound imaging to re-investigate the anatomy of the lactating breast. The breasts of 21 fully lactating women (1–6 months post partum) were scanned using an ACUSON XP10 (5–10 MHz linear array probe). The number of main ducts was measured, ductal morphology was determined, and the distribution of glandular and adipose tissue was recorded. Milk ducts appeared as hypoechoic tubular structures with echogenic walls that often contained echoes. Ducts were easily compressed and did not display typical sinuses. All ducts branched within the areolar radius, the first branch occurring 8.0 ± 5.5 mm from the nipple. Duct diameter was 1.9 ± 0.6 mm, 2.0 ± 90.7 mm and the number of main ducts was 9.6 ± 2.9, 9.2 ± 2.9, for left and right breast, respectively. Milk ducts are superficial, easily compressible and echoes within the duct represent fat globules in breastmilk. The low number and size of the ducts, the rapid branching under the areola and the absence of sinuses suggest that ducts transport breastmilk, rather than store it. The distribution of adipose and glandular tissue showed wide variation between women but not between breasts within women. The proportion of glandular and fat tissue and the number and size of ducts were not related to milk production. This study highlights inconsistencies in anatomical literature that impact on breast physiology, breastfeeding management and ultrasound assessment. PMID:15960763

  19. Changes in laboratory test results and diagnostic imaging presentation before the detection of occupational cholangiocarcinoma.

    PubMed

    Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji

    2014-01-01

    A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.

  20. Carcinoids of the common bile duct: a case report and literature review

    PubMed Central

    Ross, Alison C.; Hurley, James B.; Hay, W. Bruce; Rusnak, Conrad H.; Petrunia, Denis M.

    1999-01-01

    Carcinoids of the extrahepatic bile ducts and particularly the common bile duct are extremely rare. A 65-year-old woman presented with obstructive jaundice. Laboratory and imaging studies gave results that were consistent with an obstructing lesion in the common bile duct. In this case, a stent was inserted initially to decompress the bile ducts. Subsequently a laparotomy and pancreaticoduodenectomy were performed and a tissue diagnosis of carcinoid of the common bile duct was made. The patient was well with no evidence of recurrence 17 months postoperatively. The authors believe this is the 19th reported case of an extrahepatic bile duct carcinoid. PMID:10071590

  1. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media.

    PubMed

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B; Jansen, Sanaz A; Macleod, Kay; Conzen, Suzanne D; Karczmar, Gregory S

    2015-01-01

    The purpose of this study was to use high resolution three-dimensional (3D) magnetic resonance imaging (MRI) to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12-20 weeks (n=12), were used in this study. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple. Approximately 20-25μL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p<0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p<0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Reference values of MRI measurements of the common bile duct and pancreatic duct in children.

    PubMed

    Gwal, Kriti; Bedoya, Maria A; Patel, Neal; Rambhatla, Siri J; Darge, Kassa; Sreedharan, Ram R; Anupindi, Sudha A

    2015-07-01

    Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial measurement was 2.0 mm; the mean coronal measurement of the pancreatic duct was 0.9 mm and the axial measurement was 0.8 mm. Our study provides normative measurements for the common bile duct and pancreatic duct for children up to age 10 years. The upper limits of the CBD and pancreatic duct increase with age, and the values range 1.1-4.0 mm for the CBD and 0.6-1.9 mm for the pancreatic duct.

  3. Application of indocyanine green-fluorescence imaging to full-thickness cholecystectomy.

    PubMed

    Morita, Kiyomi; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Shimizu, Atsushi; Yamamoto, Satoshi; Takemura, Nobuyuki; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-05-01

    Fluorescence imaging using indocyanine green (ICG) has recently been applied to laparoscopic surgery to identify cancerous tissues, lymph nodes, and vascular anatomy. Here we report the application of ICG-fluorescence imaging to visualize the boundary between the liver and subserosal tissues of the gallbladder during laparoscopic full-thickness cholecystectomy. A patient with a potentially malignant gallbladder lesion was administered 2.5-mg intravenous ICG just before laparoscopic full-thickness cholecystectomy. Intraoperative fluorescence imaging enabled the real-time delineation of both extrahepatic bile duct anatomy and hepatic parenchyma throughout the procedure, which resulted in complete removal of subserosal tissues between liver and gallbladder. Safe and feasible ICG-fluorescence imaging can be widely applied to laparoscopic hepatobiliary surgery by utilizing a biliary excretion property of ICG. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  4. Carbachol-induced fluid movement through methazolamide-sensitive bicarbonate production in rat parotid intralobular ducts: quantitative analysis of fluorescence images using fluorescent dye sulforhodamine under a confocal laser scanning microscope.

    PubMed

    Nakamoto, Tetsuji; Shiba, Yoshiki; Hirono, Chikara; Sugita, Makoto; Takemoto, Kazuhisa; Iwasa, Yoshiko; Akagawa, Yasumasa

    2002-09-01

    Fluid secretion is observed at the openings of ducts in the exocrine gland. It remains unclear whether the ducts are involved in fluid secretion in the salivary glands. In the present study, we investigated the exclusion of fluorescent dye from the duct lumen by carbachol (CCh) in isolated parotid intralobular duct segments to clarify the ability of the ducts for the fluid secretion. When the membrane-impermeable fluorescent dye, sulforhodamine, was added to the superfused extracellular solution, quantitative fluorescence images of the duct lumen were obtained under the optical sectioning at the level of the duct lumen using a confocal laser scanning microscope. CCh decreased the fluorescent intensity in the duct lumen during the superfusion of the fluorescent dye, and CCh flushed out small viscous substances stained with the fluorescent dye from isolated duct lumen, suggesting that CCh might induce fluid secretion in the duct, leading to the clearance of the dye and small stained clumps from the duct lumen. CCh-induced clearance of the fluorescent dye was divided into two phases by the sensitivity to external Ca2+ and methazolamide, an inhibitor for carbonic anhydrase. The initial phase was insensitive to these, and the subsequent late phase was sensitive to these. A major portion in the late phase was inhibited by removal of bicarbonate in the superfusion solution and DPC, but not low concentration of external Cl-, bumetanide or DIDS, suggesting that methazolamide-sensitive production of HCO3-, but not the Cl- uptake mechanism, might contribute to the CCh-induced clearance of the dye from the duct lumen. These results represent the first measurements of fluid movement in isolated duct segments, and suggest that carbachol might evoke fluid secretion possibly through Ca2+-activated, DPC-sensitive anion channels with HCO3- secretion in the rat parotid intralobular ducts.

  5. Biliary and pancreatic ductal dilation in patients on methadone maintenance therapy.

    PubMed

    Bates, David D B; Tamayo-Murillo, Dorathy; Kussman, Steven; Luce, Adam; LeBedis, Christina A; Soto, Jorge A; Anderson, Stephan W

    2017-03-01

    To determine whether the diameter of intrahepatic and extrahepatic bile ducts and pancreatic ducts in patients on methadone maintenance therapy is increased when compared with control subjects. Between January 1, 2000 and March 15, 2013, a total of 97 patients (mean age 49.9, range 22-79, 65 male, 32 female) were identified who were receiving chronic methadone maintenance therapy (MMT) when they underwent imaging with abdominal MRI or a contrast-enhanced abdominopelvic CT. A group of 97 consecutive non-MMT control patients (mean age 51.4, range 21-86, 45 male, 52 female) who underwent imaging with abdominal MRI or contrast-enhanced abdominopelvic CT were identified. Patients with known pancreaticobiliary pathology that may confound biliary ductal measurements were excluded. Blinded interpretation was performed, documenting the diameters of the intrahepatic and extrahepatic bile ducts and pancreatic ducts. Descriptive statistics were performed. Patients on MMT demonstrated increased bile duct diameter, with an average increase in duct diameter of 2.39 mm for the common bile duct (p < 0.001; 95% CI 1.88-2.90 mm), 1.43 mm for the intrahepatic bile ducts (p < 0.001; 95% CI 1.12-1.74 mm), and 0.90 mm for the pancreatic duct (p < 0.001; 95% CI 0.64-1.16 mm). No statistically significant correlation was found between ductal diameters and the daily dose of methadone. Patients on methadone maintenance therapy demonstrate significantly increased intra- and extrahepatic bile duct and pancreatic duct diameter when compared with controls. There was no correlation between the dose of methadone and ductal diameter.

  6. Cholestasis‐induced adaptive remodeling of interlobular bile ducts

    PubMed Central

    Damle‐Vartak, Amruta; Richter, Beate; Dirsch, Olaf; Dahmen, Uta; Hammad, Seddik

    2016-01-01

    Cholestasis is a common complication in liver diseases that triggers a proliferative response of the biliary tree. Bile duct ligation (BDL) is a frequently used model of cholestasis in rodents. To determine which changes occur in the three‐dimensional (3D) architecture of the interlobular bile duct during cholestasis, we used 3D confocal imaging, surface reconstructions, and automated image quantification covering a period up to 28 days after BDL. We show a highly reproducible sequence of interlobular duct remodeling, where cholangiocyte proliferation initially causes corrugation of the luminal duct surface, leading to an approximately five‐fold increase in surface area. This is analogous to the function of villi in the intestine or sulci in the brain, where an expansion of area is achieved within a restricted volume. The increase in surface area is further enhanced by duct branching, branch elongation, and loop formation through self‐joining, whereby an initially relatively sparse mesh surrounding the portal vein becomes five‐fold denser through elongation, corrugation, and ramification. The number of connections between the bile duct and the lobular bile canalicular network by the canals of Hering decreases proportionally to the increase in bile duct length, suggesting that no novel connections are established. The diameter of the interlobular bile duct remains constant after BDL, a response that is qualitatively distinct from that of large bile ducts, which tend to enlarge their diameters. Therefore, volume enhancement is only due to net elongation of the ducts. Because curvature and tortuosity of the bile duct are unaltered, this enlargement of the biliary tree is caused by branching and not by convolution. Conclusion: BDL causes adaptive remodeling that aims at optimizing the intraluminal surface area by way of corrugation and branching. (Hepatology 2016;63:951–964) PMID:26610202

  7. Hyperspectral image segmentation of the common bile duct

    NASA Astrophysics Data System (ADS)

    Samarov, Daniel; Wehner, Eleanor; Schwarz, Roderich; Zuzak, Karel; Livingston, Edward

    2013-03-01

    Over the course of the last several years hyperspectral imaging (HSI) has seen increased usage in biomedicine. Within the medical field in particular HSI has been recognized as having the potential to make an immediate impact by reducing the risks and complications associated with laparotomies (surgical procedures involving large incisions into the abdominal wall) and related procedures. There are several ongoing studies focused on such applications. Hyperspectral images were acquired during pancreatoduodenectomies (commonly referred to as Whipple procedures), a surgical procedure done to remove cancerous tumors involving the pancreas and gallbladder. As a result of the complexity of the local anatomy, identifying where the common bile duct (CBD) is can be difficult, resulting in comparatively high incidents of injury to the CBD and associated complications. It is here that HSI has the potential to help reduce the risk of such events from happening. Because the bile contained within the CBD exhibits a unique spectral signature, we are able to utilize HSI segmentation algorithms to help in identifying where the CBD is. In the work presented here we discuss approaches to this segmentation problem and present the results.

  8. A new systematic classification of peripheral anatomy of the right hepatic duct: experience from adult live liver donor transplantation.

    PubMed

    Radtke, A; Sgourakis, G; Sotiropoulos, G C; Molmenti, E P; Nadalin, S; Fouzas, I; Schroeder, T; Saner, F H; Cicinnati, V R; Schenk, A; Malagó, M; Lang, H

    2008-11-01

    The peripheral intrahepatic biliary anatomy, especially at the sectorial level on the right side, has not been adequately described. The purpose of our study was to systematically describe this complex anatomy in clinically applicable fashion. We analyzed three-dimensional computed tomography (CT) imaging reconstructions of 139 potential living liver donors evaluated at our institution between January 2003 and June 2007. Eighty-nine (64%) donors had a normal right bile duct sectorial anatomy. In the other 50/139 (36%) cases, we observed abnormal sectorial branching patterns, with 45/50 abnormalities as trifurcations, whereas the remaining ones were quadrifurcations. In 22/50 (44%) abnormalities, a linear branching pattern (types B1/C1) and an early segmental origin off the right hepatic duct (types B3/C3) were present, a finding of particular danger when performing a right graft hepatectomy. In 2 cases, we noted a mixed type (B6/C6) of a rare complex anatomy. Our proposed classification of the right sectorial bile duct system clearly displays the "area at risk" encountered when performing right graft adult live donor liver transplantation and tumor resections involving the right lobe of the liver.

  9. Evaluating the Acoustic Effect of Over-the-Rotor Foam-Metal Liner Installed on a Low Speed Fan Using Virtual Rotating Microphone Imaging

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.; Dougherty, Robert P.; Walker, Bruce E.

    2010-01-01

    An in-duct beamforming technique for imaging rotating broadband fan sources has been used to evaluate the acoustic characteristics of a Foam-Metal Liner installed over-the-rotor of a low-speed fan. The NASA Glenn Research Center s Advanced Noise Control Fan was used as a test bed. A duct wall-mounted phased array consisting of several rings of microphones was employed. The data are mathematically resampled in the fan rotating reference frame and subsequently used in a conventional beamforming technique. The steering vectors for the beamforming technique are derived from annular duct modes, so that effects of reflections from the duct walls are reduced.

  10. [Imaging of the intrahepatic biliary tree with thick slice MR cholangiography].

    PubMed

    Leclerc, J C; Cannard, L; Lefèvre, F; Debelle, L; Béot, S; Boccaccini, H; Bazin, C; Régent, D

    2001-02-01

    To assess the value of single shot fast spin echo MR sequence (SS-FSE) in the evaluation of the normal and pathologic intrahepatic biliary tree. 418 consecutive patients (457 examinations) referred for clinical and/or biological suspicion of biliary obstruction underwent MR cholangiopancreatography (MRCP). All patients were imaged with a Signa 1.5 T GE MR unit, with High Gradient Field Strength and Torso Phased Array Coil. Biliary ducts were imaged with SS-FSE sequence, coronal and oblique coronal 20 mm thick slices on a 256 x 256 matrix. Total acquisition time was 1 second. Source images were reviewed by two radiologists blinded to clinical information. In case of disagreement, a third radiologist's opinion was requested. In all cases, MRCP results were compared with direct biliary tract evaluation, other imaging studies and clinical and biological follow-up. In all cases, MRCP produced high quality images. Numerous branch of division were observed although the peripheral intrahepatic ducts were well seen in more than 90% in an area 2 cm below the capsule. The number of division was statistically higher when mechanical obstruction was present. Intrahepatic calculi or peripheral cholangiocarcinoma were well detect by MRCP. For the detection of cholangitis, MRCP sensitivity was 87.5% but the positive predictive value was only 57.7% because of a high number of false positive. The diagnosis of primary sclerosing cholangitis must be made only on strict criteria and slightly dilated peripheral bile ducts unconnected to the central ducts in several hepatic segments were a characteristic MR sign of primary sclerosing cholangitis. MRCP can be proposed as a first intention imaging technique for the evaluation of intrahepatic ducts.

  11. Laparoscopic completion cholecystectomy and common bile duct exploration for retained gallbladder after single-incision cholecystectomy.

    PubMed

    Kroh, Matthew; Chalikonda, Sricharan; Chand, Bipan; Walsh, R Matthew

    2013-01-01

    Recent enthusiasm in the surgical community for less invasive surgical approaches has resulted in widespread application of single-incision techniques. This has been most commonly applied in laparoscopic cholecystectomy in general surgery. Cosmesis appears to be improved, but other advantages remain to be seen. Feasibility has been demonstrated, but there is little description in the current literature regarding complications. We report the case of a patient who previously underwent single-incision laparoscopic cholecystectomy for symptomatic gallstone disease. After a brief symptom-free interval, she developed acute pancreatitis. At evaluation, imaging results of ultrasonography and magnetic resonance cholangiopancreatography demonstrated a retained gallbladder with cholelithiasis. The patient was subsequently referred to our hospital, where she underwent further evaluation and surgical intervention. Our patient underwent 4-port laparoscopic remnant cholecystectomy with transcystic common bile duct exploration. Operative exploration demonstrated a large remnant gallbladder and a partially obstructed cystic duct with many stones. Transcystic exploration with balloon extraction resulted in duct clearance. The procedure took 75 minutes, with minimal blood loss. The patient's postoperative course was uneventful. Final pathology results demonstrated a remnant gallbladder with cholelithiasis and cholecystitis. This report is the first in the literature to describe successful laparoscopic remnant cholecystectomy and transcystic common bile duct exploration after previous single-port cholecystectomy. Although inadvertent partial cholecystectomy is not unique to this technique, single-port laparoscopic procedures may result in different and significant complications.

  12. Bile produced in the liver (image)

    MedlinePlus

    ... duct system that creates, transports, stores, and releases bile into the duodenum for digestion includes the liver, gallbladder, and bile ducts (named the cystic, hepatic, common, and pancreatic ...

  13. [Rare bile duct anatomy variant - Right bile duct intraparenchymal junction into the left bile duct].

    PubMed

    Gál, Adrián Róbert; Kalmár-Nagy, Károly; Fincsur, András; Horváth, Örs Péter; Vereczkei, András

    2018-03-01

    The authors present a case of a 67-year-old male patient, who previously had been diagnosed with a malignant liver tumor localized in segment II. He underwent bisegmentectomy (II and III) and partial IV segmentectomy. After the primary surgery jaundice developed, the level of bilirubin increased and after several imaging modalities reoperation was indicated. During the surgery a rare bile duct anatomy variant was found. The right hepatic duct joined the left duct in the parenchyma of the left lobe, and was ligated at the resection. As the liver hilum was not explored, the absence of the right duct was not discovered. Reconstruction of the biliary system was accomplished by a Roux-en-Y loop.

  14. Radiation-Induced Damage to Microstructure of Parotid Gland: Evaluation Using High-Resolution Magnetic Resonance Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kan, Tomoko, E-mail: tkan@grape.med.tottori-u.ac.j; Kodani, Kazuhiko; Michimoto, Koichi

    Purpose: To elucidate the radiation-induced damage to the microstructure of the parotid gland using high-resolution magnetic resonance imaging. Methods and Materials: High-resolution magnetic resonance imaging of the parotid gland was performed before radiotherapy (RT) and during the RT period or {<=}3 weeks after RT completion for 12 head-and-neck cancer patients using a 1.5-T scanner with a microscopy coil. The maximal cross-sectional area of the gland was evaluated, and changes in the internal architecture of the gland were assessed both visually and quantitatively. Results: Magnetic resonance images were obtained at a median parotid gland dose of 36 Gy (range, 11-64). Accordingmore » to the quantitative analysis, the maximal cross-sectional area of the gland was reduced, the width of the main duct was narrowed, and the intensity ratio of the main duct lumen to background was significantly decreased after RT (p <.0001). According to the visual assessment, the width of the main duct tended to narrow and the contrast of the duct lumen tended to be decreased, but no significant differences were noted. The visibility of the duct branches was unclear in 10 patients (p = .039), and the septum became dense in 11 patients (p = .006) after RT. Conclusion: High-resolution magnetic resonance imaging is a noninvasive method of evaluating radiation-induced changes to the internal architecture of the parotid gland. Morphologic changes in the irradiated parotid gland were demonstrated during the RT course even when a relatively small dose was delivered to the gland.« less

  15. Improving patient and user safety during endoscopic investigation of the pancreatic and biliary ducts

    NASA Astrophysics Data System (ADS)

    Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.

    2011-03-01

    Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.

  16. The role of diffusion-weighted MR imaging for differentiating benign from malignant bile duct strictures.

    PubMed

    Park, Hyun Jeong; Kim, Seong Hyun; Jang, Kyung Mi; Choi, Seo-youn; Lee, Soon Jin; Choi, Dongil

    2014-04-01

    To assess the added value of diffusion-weighted imaging (DWI) to conventional magnetic resonance imaging (MRI) for differentiating benign from malignant bile duct strictures. Twenty-seven patients with a benign stricture and 42 patients with a malignant stricture who had undergone gadoxetic acid-enhanced MRI with DWI were enrolled. Qualitative (signal intensity, dynamic enhancement pattern) and quantitative (wall thickness and length) analyses were performed. Two observers independently reviewed a set of conventional MRI and a combined set of conventional MRI and DWI, and receiver operating characteristic (ROC) curve analysis was assessed. Benign strictures showed isointensity (18.5-70.4 %) and a similar enhancement pattern (22.2 %) to that of normal bile duct more frequently than malignant strictures (0-40.5 % and 0 %) on conventional MRI (P < 0.05). Malignant strictures (90.5-92.9 %) showed hypervascularity on arterial and portal venous phase images more frequently than benign strictures (37.0-70.4 %) (P < 0.01) On DWI, all malignant strictures showed hyperintensity compared with benign cases (70.4 %) (P < 0.001). Malignant strictures were significantly thicker and longer than benign strictures (P < 0.001). The diagnostic performance of both observers improved significantly after additional review of DWI. Adding DWI to conventional MRI is more helpful for differentiating benign from malignant bile duct strictures than conventional MRI alone. • Accurate diagnosis and exclusion of benign strictures of bile duct are important. • Diffusion-weighted MRI helps to distinguish benign from malignant bile duct strictures. • DWI plus conventional MRI provides superior diagnostic accuracy to conventional MRI alone.

  17. New look inside human breast ducts with Raman imaging. Raman candidates as diagnostic markers for breast cancer prognosis: Mammaglobin, palmitic acid and sphingomyelin.

    PubMed

    Abramczyk, Halina; Brozek-Pluska, Beata

    2016-02-25

    Looking inside the human body fascinated mankind for thousands of years. Current diagnostic and therapy methods are often limited by inadequate sensitivity, specificity and spatial resolution. Raman imaging may bring revolution in monitoring of disease and treatment. The main advantage of Raman imaging is that it gives spatial information about various chemical constituents in defined cellular organelles in contrast to conventional methods (liquid chromatography/mass spectrometry, NMR, HPLC) that rely on bulk or fractionated analyses of extracted components. We demonstrated how Raman imaging can drive the progress on breast cancer just unimaginable a few years ago. We looked inside human breast ducts answering fundamental questions about location and distribution of various biochemical components inside the lumen, epithelial cells of the duct and the stroma around the duct during cancer development. We have identified Raman candidates as diagnostic markers for breast cancer prognosis: carotenoids, mammaglobin, palmitic acid and sphingomyelin as key molecular targets in ductal breast cancer in situ, and propose the molecular mechanisms linking oncogenes with lipid programming. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Application of Variational Methods to the Thermal Entrance Region of Ducts

    NASA Technical Reports Server (NTRS)

    Sparrow, E. M.; Siegel. R.

    1960-01-01

    A variational method is presented for solving eigenvalue problems which arise in connection with the analysis of convective heat transfer in the thermal entrance region of ducts. Consideration is given, to both situations where the temperature profile depends upon one cross-sectional coordinate (e.g. circular tube) or upon two cross-sectional coordinates (e.g. rectangular duct). The variational method is illustrated and verified by application to laminar heat transfer in a circular tube and a parallel-plate channel, and good agreement with existing numerical solutions is attained. Then, application is made to laminar heat transfer in a square duct as a check, an alternate computation for the square duct is made using a method indicated by Misaps and Pohihausen. The variational method can, in principle, also be applied to problems in turbulent heat transfer.

  19. Pancreatic hardness: Correlation of surgeon’s palpation, durometer measurement and preoperative magnetic resonance imaging features

    PubMed Central

    Hong, Tae Ho; Choi, Joon-Il; Park, Michael Yong; Rha, Sung Eun; Lee, Young Joon; You, Young Kyoung; Choi, Moon Hyung

    2017-01-01

    AIM To evaluate the correlation between subjective assessments of pancreatic hardness based on the palpation, objective measurements using a durometer, and magnetic resonance imaging (MRI) findings for assessing pancreatic hardness. METHODS Eighty-three patients undergoing pancreatectomies were enrolled. An experienced surgeon subjectively evaluated the pancreatic hardness in the surgical field by palpation. The pancreatic hardness was also objectively evaluated using a durometer. Preoperative MRI findings were evaluated by a radiologist in terms of the apparent diffusion coefficient (ADC) values, the relative signal intensity decrease (RSID) of the pancreatic parenchyma, and the diameter of the pancreatic parenchyma and duct. Durometer measurement results, ADC values, RSID, pancreatic duct and parenchyma diameters, and the ratio of the diameters of the duct and parenchyma were compared between pancreases judged to be soft or hard pancreas on the palpation. A correlation analysis was also performed between the durometer and MRI measurements. RESULTS The palpation assessment classified 44 patients as having a soft pancreas and 39 patients as having a hard pancreas. ADC values were significantly lower in the hard pancreas group. The ductal diameter and duct-to-pancreas ratio were significantly higher in the hard pancreas group. For durometer measurements, a correlation analysis showed a positive correlation with the ductal diameter and the duct-to-pancreas ratio and a negative correlation with ADC values. CONCLUSION Hard pancreases showed lower ADC values, a wider pancreatic duct diameter and a higher duct-to-pancreas ratio than soft pancreases. Additionally, the ADC values, diameter of the pancreatic duct and duct-to-pancreas ratio were closely correlated with the durometer results. PMID:28373771

  20. Pancreatic hardness: Correlation of surgeon's palpation, durometer measurement and preoperative magnetic resonance imaging features.

    PubMed

    Hong, Tae Ho; Choi, Joon-Il; Park, Michael Yong; Rha, Sung Eun; Lee, Young Joon; You, Young Kyoung; Choi, Moon Hyung

    2017-03-21

    To evaluate the correlation between subjective assessments of pancreatic hardness based on the palpation, objective measurements using a durometer, and magnetic resonance imaging (MRI) findings for assessing pancreatic hardness. Eighty-three patients undergoing pancreatectomies were enrolled. An experienced surgeon subjectively evaluated the pancreatic hardness in the surgical field by palpation. The pancreatic hardness was also objectively evaluated using a durometer. Preoperative MRI findings were evaluated by a radiologist in terms of the apparent diffusion coefficient (ADC) values, the relative signal intensity decrease (RSID) of the pancreatic parenchyma, and the diameter of the pancreatic parenchyma and duct. Durometer measurement results, ADC values, RSID, pancreatic duct and parenchyma diameters, and the ratio of the diameters of the duct and parenchyma were compared between pancreases judged to be soft or hard pancreas on the palpation. A correlation analysis was also performed between the durometer and MRI measurements. The palpation assessment classified 44 patients as having a soft pancreas and 39 patients as having a hard pancreas. ADC values were significantly lower in the hard pancreas group. The ductal diameter and duct-to-pancreas ratio were significantly higher in the hard pancreas group. For durometer measurements, a correlation analysis showed a positive correlation with the ductal diameter and the duct-to-pancreas ratio and a negative correlation with ADC values. Hard pancreases showed lower ADC values, a wider pancreatic duct diameter and a higher duct-to-pancreas ratio than soft pancreases. Additionally, the ADC values, diameter of the pancreatic duct and duct-to-pancreas ratio were closely correlated with the durometer results.

  1. Differentiation of benign and malignant hilar bile duct stenosis.

    PubMed

    Liu, Xiaolei; Yang, Zhiying; Tan, Haidong; Shao, Chen; Liu, Liguo; Si, Shuang; Xu, Li; Sun, Yongliang

    2016-06-15

    Failure to differentiate benign and malignant hilar bile duct stenosis may lead to inappropriate treatment. We retrospectively analyzed the methods for differentiation. A total of 53 patients with hilar bile duct stenosis were included, comprising 41 malignant cases (hilar cholangiocarcinoma) and 12 benign cases (six primary sclerosing cholangitis and six IgG4-associated sclerosing cholangitis). Data of clinical histories, laboratory tests, imaging studies, and liver pathologies were collected, and comparison was made between benign and malignant groups. Compared with malignant group, patients in the benign group were more likely to have multiorgan involvement of clinical histories (P < 0.001). There was no difference on bilirubin, liver enzyme, and serum tumor marker between the two groups, whereas serum IgG4 levels were higher in the benign group (P = 0.003). Patients in the benign group were more likely to have pancreatic changes (P < 0.001) and multiple-segmental bile duct stenosis (P < 0.001) on imaging. Compared with the malignant group, patients in the benign group were more likely to show severe periportal inflammation in noninvolved liver (P < 0.001), fibrosis around intrahepatic bile duct (P < 0.001), and more IgG4-positive plasma cells (P < 0.001) on liver pathology. Benign lesion should be considered for patients with history of multiorgan involvement, pancreas changes, or multiple-segmental bile duct stenosis on imaging. Liver biopsy could be helpful for differential diagnosis before surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Modeling of Field-Aligned Guided Echoes in the Plasmasphere

    NASA Technical Reports Server (NTRS)

    Fung, Shing F.; Green, James L.

    2004-01-01

    The conditions under which high frequency (f>>f(sub uh)) long-range extraordinary-mode discrete field-aligned echoes observed by the Radio Plasma Imager (RPI) on board the Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) satellite in the plasmasphere are investigated by ray tracing modeling. Field-aligned discrete echoes are most commonly observed by RPI in the plasmasphere although they are also observed over the polar cap region. The plasmasphere field-aligned echoes appearing as multiple echo traces at different virtual ranges are attributed to signals reflected successively between conjugate hemispheres that propagate along or nearly along closed geomagnetic field lines. The ray tracing simulations show that field-aligned ducts with as little as 1% density perturbations (depletions) and less than 10 wavelengths wide can guide nearly field-aligned propagating high frequency X mode waves. Effective guidance of wave at a given frequency and wave normal angle (Psi) depends on the cross-field density scale of the duct, such that ducts with stronger density depletions need to be wider in order to maintain the same gradient of refractive index across the magnetic field. While signal guidance by field aligned density gradient without ducting is possible only over the polar region, conjugate field-aligned echoes that have traversed through the equatorial region are most likely guided by ducting.

  3. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media

    PubMed Central

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B.; Jansen, Sanaz A.; Macleod, Kay; Conzen, Suzanne D.; Karczmar, Gregory S.

    2014-01-01

    The purpose of this study was to use high resolution 3D MRI to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12–20 weeks (n = 12), were used in this study. A 34G, 45° tip Hamilton needle with a 25uL Hamilton syringe was inserted into the tip of the nipple. Approximately 20–25uL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p < 0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p < 0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. PMID:25179139

  4. A case of peribiliary cysts accompanying bile duct carcinoma

    PubMed Central

    Miura, Fumihiko; Takada, Tadahiro; Amano, Hodaka; Yoshida, Masahiro; Isaka, Takahiro; Toyota, Naoyuki; Wada, Keita; Takagi, Kenji; Kato, Kenichiro

    2006-01-01

    A rare case of peribiliary cysts accompanying bile duct carcinoma is presented. A 54-year-old man was diagnosed as having lower bile duct carcinoma and peribiliary cysts by diagnostic imaging. He underwent pylorus preserving pancreatoduodenectomy. As for the peribiliary cysts, a course of observation was taken. Over surgery due to misdiagnosis of patients with biliary malignancy accompanied by peribiliary cysts should be avoided. PMID:16874882

  5. Application of syntactic methods of pattern recognition for data mining and knowledge discovery in medicine

    NASA Astrophysics Data System (ADS)

    Ogiela, Marek R.; Tadeusiewicz, Ryszard

    2000-04-01

    This paper presents and discusses possibilities of application of selected algorithms belonging to the group of syntactic methods of patten recognition used to analyze and extract features of shapes and to diagnose morphological lesions seen on selected medical images. This method is particularly useful for specialist morphological analysis of shapes of selected organs of abdominal cavity conducted to diagnose disease symptoms occurring in the main pancreatic ducts, upper segments of ureters and renal pelvis. Analysis of the correct morphology of these organs is possible with the application of the sequential and tree method belonging to the group of syntactic methods of pattern recognition. The objective of this analysis is to support early diagnosis of disease lesions, mainly characteristic for carcinoma and pancreatitis, based on examinations of ERCP images and a diagnosis of morphological lesions in ureters as well as renal pelvis based on an analysis of urograms. In the analysis of ERCP images the main objective is to recognize morphological lesions in pancreas ducts characteristic for carcinoma and chronic pancreatitis, while in the case of kidney radiogram analysis the aim is to diagnose local irregularities of ureter lumen and to examine the morphology of renal pelvis and renal calyxes. Diagnosing the above mentioned lesion has been conducted with the use of syntactic methods of pattern recognition, in particular the languages of description of features of shapes and context-free sequential attributed grammars. These methods allow to recognize and describe in a very efficient way the aforementioned lesions on images obtained as a result of initial image processing of width diagrams of the examined structures. Additionally, in order to support the analysis of the correct structure of renal pelvis a method using the tree grammar for syntactic pattern recognition to define its correct morphological shapes has been presented.

  6. Endoscopic retrograde cholangio pancreatography (ERCP) - series (image)

    MedlinePlus

    ... small intestine, also called the duodenum. The common bile duct carries bile from the liver to the duodenum, and enters ... sometimes pass from the gallbladder into the common bile duct, and block the flow of bile into ...

  7. Magnetic resonance T1 gradient-echo imaging in hepatolithiasis.

    PubMed

    Safar, F; Kamura, T; Okamuto, K; Sasai, K; Gejyo, F

    2005-01-01

    We examined the role of magnetic resonance T1-weighted gradient-echo (MRT1-GE) imaging in hepatolithiasis. MRT1-GE, precontrast computed tomography (CT), and magnetic resonance cholangiopancreatography (MRCP) of 10 patients with hepatolithiasis were compared for their diagnostic accuracies in the detection and localization of intrahepatic calculi. The diagnosis of hepatolithiasis was confirmed by surgery. For localization of the stone, we divided the bile ducts into six areas: right and left hepatic ducts and bile ducts of the lateral, medial, right anterior, and right posterior segments of the liver. Chemical analysis of the stones was performed in eight patients. The total number of segments proved by surgery to contain stones was 18. Although not significantly different, the sensitivity of MRT1-GE was 77.8% (14 of 18 segments), higher than that of MRCP (66.7%, 12 of 18 segments) and that of CT (50%, nine of 18 segments). The sensitivity of magnetic resonance imaging (MRCP + MRT1) was significantly higher than that of CT (p < 0.01). Multiple logistic regression analysis showed that the result of surgery was significantly affected only by the result of magnetic resonance imaging. On MRT1-GE, all the depicted stones appeared as high-intensity signal areas within the low-intensity bile duct irrespective of their chemical composition. MRT1-GE imaging provides complementary information concerning hepatolithiasis.

  8. Ceftriaxone-associated pancreatitis captured on serial computed tomography scans.

    PubMed

    Nakagawa, Nozomu; Ochi, Nobuaki; Yamane, Hiromichi; Honda, Yoshihiro; Nagasaki, Yasunari; Urata, Noriyo; Nakanishi, Hidekazu; Kawamoto, Hirofumi; Takigawa, Nagio

    2018-02-01

    A 74-year-old man was treated with ceftriaxone for 5 days and subsequently experienced epigastric pain. Computed tomography (CT) was performed 7 and 3 days before epigastralgia. Although the first CT image revealed no radiographic signs in his biliary system, the second CT image revealed dense radiopaque material in the gallbladder lumen. The third CT image, taken at symptom onset, showed high density in the common bile duct and enlargement of the pancreatic head. This is a very rare case of pseudolithiasis involving the common bile duct, as captured on a series of CT images.

  9. Congenital dilatation of the intrahepatic bile ducts associated with the development of amyloidosis

    PubMed Central

    Fevery, J.; Tanghe, W.; Kerremans, R.; Desmet, V.; De Groote, J.

    1972-01-01

    Two cases of pure congenital dilatation of the intrahepatic bile ducts are presented. One patient developed amyloidosis secondary to suppuration, and had isolated cysts in the renal medulla. The position of congenital dilatation of the intrahepatic bile ducts compared with cysts in the liver and its association with `cystic' diseases of the kidneys is discussed. ImagesFig. 1Fig. 2Fig. 3Fig. 4 PMID:5077171

  10. Hollow lensing duct

    DOEpatents

    Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Mitchell, Scott; Lang, John; Maderas, Dennis; Speth, Joel; Payne, Stephen A.

    2000-01-01

    A hollow lensing duct to condense (intensify) light using a combination of focusing using a spherical or cylindrical lens followed by reflective waveguiding. The hollow duct tapers down from a wide input side to a narrow output side, with the input side consisting of a lens that may be coated with an antireflective coating for more efficient transmission into the duct. The inside surfaces of the hollow lens duct are appropriately coated to be reflective, preventing light from escaping by reflection as it travels along the duct (reflective waveguiding). The hollow duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials.

  11. Virtual endoscopic imaging of the spine.

    PubMed

    Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei

    2012-05-20

    Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.

  12. Intraluminal occlusion of the seminal duct by laser and Histoacryl: Two non-invasive alternatives for vasectomy

    NASA Astrophysics Data System (ADS)

    Freitag, B.; Sroka, R.; Koelle, S.; Becker, A. J.; Khoder, W.; Pongratz, T.; Stief, C. G.; Trottmann, M.

    2014-03-01

    Introduction and objective: Vasectomy is a well-established method in family control. Even though it is a safe and low risk operation, this surgery is invasive and difficult to reverse. Therefore the aim of this study was to investigate new non-invasive methods for occlusion of the seminal duct. Material and Methods: Seminal duct tissue was obtained from patients (n=30) suffering from prostate cancer and therefore undergoing prostatectomy. In a first set of experiments, the seminal duct was occluded by intraluminal application of Histoacryl® (Braun Aesculap AG, Tuttlingen, Germany). In a 2nd set of experiments, endoluminal laser induced occlusion was performed. Four different laser wavelengths (1940nm, 1470nm, 1064nm, 940nm) and different sets of laser parameters (e.g. power, exposure duration, fibre diameter, energy applied) were compared. Effectiveness of occlusion of the seminal duct was proven by post-treatment irrigation flow measurement, as well as by morphological analyses. To evaluate a potential damage of the surrounding tissue, external temperature was measured using a thermometer during laser application. Results: Intraluminal application of Histoacryl® induced an immediate and complete occlusion of the seminal duct. The underlying connective tissue maintained its functional integrity after this treatment. By laser light application to a Histoacryl® block, a hole could be created into the block thus indicating the possibility of recanalization. Treatment with laser energy resulted in shrinkage of the ductal lumen. The laser application generally caused necrosis in the epithelium and induced formation of vacuoles in the underlying connective tissue. As described for endoluminal varicose treatment, this distinct local reaction might result in an intense inflammation leading to a functional occlusion of the vas deferens. Conclusions: Both laser-induced occlusion and application of Histoacryl® are fast and simple techniques which may be able to achieve a functional occlusion of the seminal duct. The application of Histoacryl® additionally may be easily reversible by laser treatment.

  13. Application of the PJ and NPS evaporation duct models over the South China Sea (SCS) in winter

    PubMed Central

    Yang, Shaobo; Li, Xingfei; Wu, Chao; He, Xin; Zhong, Ying

    2017-01-01

    The detection of duct height has a significant effect on marine radar or wireless apparatus applications. The paper presents two models to verify the adaptation of evaporation duct models in the SCS in winter. A meteorological gradient instrument used to measure evaporation ducts was fabricated using hydrological and meteorological sensors at different heights. An experiment on the adaptive characteristics of evaporation duct models was carried out over the SCS. The heights of the evaporation ducts were measured by means of log-linear fit, Paulus-Jeske (PJ) and Naval Postgraduate School (NPS) models. The results showed that NPS model offered significant advantages in stability compared with the PJ model. According the collected data computed by the NPS model, the mean deviation (MD) was -1.7 m, and the Standard Deviation (STD) of the MD was 0.8 m compared with the true value. The NPS model may be more suitable for estimating the evaporation duct height in the SCS in winter due to its simpler system characteristics compared with meteorological gradient instruments. PMID:28273113

  14. Lensing duct

    DOEpatents

    Beach, R.J.; Benett, W.J.

    1994-04-26

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.

  15. In vivo imaging of human labial glands using advanced optical coherence tomography.

    PubMed

    Ozawa, Nobuyoshi; Sumi, Yasunori; Shimozato, Kazuo; Chong, Changho; Kurabayashi, Tohru

    2009-09-01

    Optical coherence tomography (OCT) has emerged as a high-resolution noninvasive clinical imaging application. The purpose of this study was to show OCT images of human labial glands obtained using a swept-source (SS) OCT system. Labial gland OCT imaging was carried out using our new SS-OCT system for 5 healthy volunteers using a hand-held in vivo OCT scanning probe. The labial tissue was scanned in a superior to inferior direction in 2 and 3 dimensions. The resulting 2- and 3-dimensional ultrahigh-resolution images of in vivo OCT human labial minor salivary glands revealed the epithelium, connective tissue, lobes, and duct. OCT was capable of providing simultaneous and noninvasive structural information with high resolution. This clinical imaging modality promises to have clinical impact in the diagnosis of such conditions as Sjögren syndrome and xerostomia.

  16. Objective breast tissue image classification using Quantitative Transmission ultrasound tomography

    NASA Astrophysics Data System (ADS)

    Malik, Bilal; Klock, John; Wiskin, James; Lenox, Mark

    2016-12-01

    Quantitative Transmission Ultrasound (QT) is a powerful and emerging imaging paradigm which has the potential to perform true three-dimensional image reconstruction of biological tissue. Breast imaging is an important application of QT and allows non-invasive, non-ionizing imaging of whole breasts in vivo. Here, we report the first demonstration of breast tissue image classification in QT imaging. We systematically assess the ability of the QT images’ features to differentiate between normal breast tissue types. The three QT features were used in Support Vector Machines (SVM) classifiers, and classification of breast tissue as either skin, fat, glands, ducts or connective tissue was demonstrated with an overall accuracy of greater than 90%. Finally, the classifier was validated on whole breast image volumes to provide a color-coded breast tissue volume. This study serves as a first step towards a computer-aided detection/diagnosis platform for QT.

  17. Agenesis of the gallbladder with hypoplastic cystic duct diagnosed at laparoscopy.

    PubMed

    Kwon, A-Hon; Yanagimoto, Hiroaki; Matsui, Yoichi; Imamura, Atsushi

    2006-08-01

    An 86-year-old man was admitted to our department with complaints of intermittent upper abdominal pain. Ultrasonography of the abdomen showed dilated extrahepatic bile ducts containing stones; however, the gallbladder was not clearly identified. Magnetic resonance cholangiopancreatography showed dilated extrahepatic ducts and choledocholithiasis without gallbladder visualization. The stone extraction was performed with endoscopic sphincterotomy. Three-dimensional images using spiral-computed tomography after intravenous-infusion cholangiography clearly demonstrated an obstruction of the cystic duct. The patient was scheduled for laparoscopic cholecystectomy. At laparoscopy, the gallbladder fossa was not identified on the undersurface of the liver. Despite a thorough examination of the intrahepatic (left-sided within the lesser omentum), retroperitoneal, retrohepatic (within the falciform ligament), retroduodenal, and retropancreatic areas using laparoscopic ultrasonography, the gallbladder was not found. After careful dissection of the hepatoduodenal ligament, the dilated extrahepatic bile duct and a 1-cm length of hypoplastic cystic duct were found. Gallbladder agenesis is usually accompanied by the lack of the cystic duct. The present case is the third report of gallbladder agenesis with a patent or hypoplastic cystic duct.

  18. The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp; Shirono, Ryozo; Takechi, Katsuya

    Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differencesmore » in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.« less

  19. A portable fluorescence microscopic imaging system for cholecystectomy

    NASA Astrophysics Data System (ADS)

    Ye, Jian; Yang, Chaoyu; Gan, Qi; Ma, Rong; Zhang, Zeshu; Chang, Shufang; Shao, Pengfei; Zhang, Shiwu; Liu, Chenhai; Xu, Ronald

    2016-03-01

    In this paper we proposed a portable fluorescence microscopic imaging system to prevent iatrogenic biliary injuries from occurring during cholecystectomy due to misidentification of the cystic structures. The system consisted of a light source module, a CMOS camera, a Raspberry Pi computer and a 5 inch HDMI LCD. Specifically, the light source module was composed of 690 nm and 850 nm LEDs, allowing the CMOS camera to simultaneously acquire both fluorescence and background images. The system was controlled by Raspberry Pi using Python programming with the OpenCV library under Linux. We chose Indocyanine green(ICG) as a fluorescent contrast agent and then tested fluorescence intensities of the ICG aqueous solution at different concentration levels by our fluorescence microscopic system compared with the commercial Xenogen IVIS system. The spatial resolution of the proposed fluorescence microscopic imaging system was measured by a 1951 USAF resolution target and the dynamic response was evaluated quantitatively with an automatic displacement platform. Finally, we verified the technical feasibility of the proposed system in mouse models of bile duct, performing both correct and incorrect gallbladder resection. Our experiments showed that the proposed system can provide clear visualization of the confluence between the cystic duct and common bile duct or common hepatic duct, suggesting that this is a potential method for guiding cholecystectomy. The proposed portable system only cost a total of $300, potentially promoting its use in resource-limited settings.

  20. A quadriplegic patient's cholescintigraphic findings: delayed gallbladder visualization and common bile duct dilation.

    PubMed Central

    Shih, W. J.; Magoun, S.; Lu, G.

    1996-01-01

    A Tc-99m DISIDA cholescintigraphic study of a 37-year-old patient with a 20-year history of quadriplegia demonstrated dilation of the common bile duct and delayed gallbladder visualization. A concurrent sonographic study showed an enlarged gallbladder with stones and dilation of the common bile duct. These findings were proved by autopsy. Quadriplegia secondary to a high level of spinal cord injury may result in gallbladder dysfunction. Images Figure PMID:8776068

  1. CT differentiation of mucin-producing cystic neoplasms of the liver from solitary bile duct cysts.

    PubMed

    Kim, Hyoung Jung; Yu, Eun Sil; Byun, Jae Ho; Hong, Seung-Mo; Kim, Kyoung Won; Lee, Jong Seok; Kim, So Yeon

    2014-01-01

    The purpose of this study was to identify the CT features required for differentiating mucin-producing cystic neoplasms of the liver (mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct) from solitary bile duct cysts. CT images of pathologically confirmed mucinous cystic neoplasms (n = 15), cyst-forming intraductal papillary neoplasms of the bile duct (n = 16), and solitary bile duct cysts (n = 31) were reviewed. Analysis of the CT findings included shape, presence of septa, location of septa (peripheral vs central), thickness of septa (thin vs thick), mosaic pattern, mural nodules, intracystic debris, calcification, upstream bile duct dilatation, downstream bile duct dilatation, and communication between a cystic lesion and the bile duct. The maximum size of a cystic lesion and the maximum size of the largest mural nodule were measured. The presence of septa, central septa, mural nodules, upstream bile duct dilatation, and downstream bile duct dilatation were found to be significant CT findings for differentiating mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct from solitary bile duct cysts (p < 0.05 for each finding). When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucin-producing cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively. When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively [corrected]. With the use of specific CT criteria, mucin-producing cystic neoplasms of the liver can be differentiated from solitary bile duct cysts with a high degree of accuracy.

  2. Value of three-dimensional gradient-echo magnetic resonance cholangiography in diagnosing choledocholithiasis.

    PubMed

    Rawat, B; Loewy, J

    1996-08-01

    To evaluate the role of magnetic resonance cholangiography (MRC) in patients with suspected choledocholithiasis. Twenty-six consecutive patients with suspected choledocholithiasis (11 men and 15 women ranging in age from 25 to 81 years) underwent three-dimensional gradient-echo MRC; each patient also underwent endoscopic retrograde cholangiography or operative cholangiography. Each set of images for each patient was reviewed independently by a radiologist who was unaware of the results of the other type of imaging. Diagnostic-quality MRC images were obtained for 17 of the patients. Of these, 13 had stones in the common bile duct, as confirmed by another imaging method, and MRC indicated the presence of these stones in all 13 patients. In the other four patients bile duct obstruction was due to either acute pancreatitis (in three) or cholangiocarcinoma (in one). For seven of the nine nondiagnostic-quality MRC studies, the bile duct was not obstructed, so there was no bile stasis and the MRC images could not be obtained. Motion artifacts due to inability to hold the breath were the limiting factors in the other two patients. Although MRC has some limitations, this new noninvasive technique may be used as a screening test in selected patients with suspected choledocholithiasis.

  3. PMR Graphite Engine Duct Development

    NASA Technical Reports Server (NTRS)

    Stotler, C. L.; Yokel, S. A.

    1989-01-01

    The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.

  4. Acoustics flow analysis in circular duct using sound intensity and dynamic mode decomposition

    NASA Astrophysics Data System (ADS)

    Weyna, S.

    2014-08-01

    Sound intensity generation in hard-walled duct with acoustic flow (no mean-flow) is treated experimentally and shown graphically. In paper, numerous methods of visualization illustrating the vortex flow (2D, 3D) can graphically explain diffraction and scattering phenomena occurring inside the duct and around open end area. Sound intensity investigation in annular duct gives a physical picture of sound waves in any duct mode. In the paper, modal energy analysis are discussed with particular reference to acoustics acoustic orthogonal decomposition (AOD). The image of sound intensity fields before and above "cut-off" frequency region are found to compare acoustic modes which might resonate in duct. The experimental results show also the effects of axial and swirling flow. However acoustic field is extremely complicated, because pressures in non-propagating (cut-off) modes cooperate with the particle velocities in propagating modes, and vice versa. Measurement in cylindrical duct demonstrates also the cut-off phenomenon and the effect of reflection from open end. The aim of experimental study was to obtain information on low Mach number flows in ducts in order to improve physical understanding and validate theoretical CFD and CAA models that still may be improved.

  5. Biliary tract variations of the left liver with special reference to the left medial sectional bile duct in 500 patients.

    PubMed

    Furusawa, Norihiko; Kobayashi, Akira; Yokoyama, Takahide; Shimizu, Akira; Motoyama, Hiroaki; Kanai, Keita; Arakura, Norikazu; Yamada, Akira; Kitou, Yoshihiro; Miyagawa, Shin-Ichi

    2015-08-01

    Among the intrahepatic bile ducts, the biliary system of the left medial sectional bile duct (B4) is known to have relatively complex patterns. The records of 500 patients who had been diagnosed as having hepato-pancreatico-biliary disease were retrospectively studied for anatomical biliary variations of the left liver with special reference to the drainage system of B4 using magnetic resonance images. The left hepatic duct was present in 494 patients (98.8%), whereas it was lacking in 6 patients (1.2%), and these patients exhibited the following B4 confluence patterns: B4 drained into the common hepatic duct in 2 patients (.4%), the right anterior sectional bile duct in 3 patients (.6%), and the right posterior sectional bile duct in 1 patient (.2%). The left hepatic duct was absent more frequently in patients with portal venous variations than in patients with a common branching pattern (8.2% vs .4%, P = .0011). The presently reported data are useful for obtaining a better understanding of the surgical anatomy of the biliary system of the left liver. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Direct Gallbladder Indocyanine Green Injection Fluorescence Cholangiography During Laparoscopic Cholecystectomy.

    PubMed

    Graves, Claire; Ely, Sora; Idowu, Olajire; Newton, Christopher; Kim, Sunghoon

    2017-10-01

    Intravenous injection of indocyanine green (ICG) is used to illuminate extrahepatic biliary anatomy. Fluorescence of biliary structures may lower surgical complications that can arise due to inadvertent injury to the common bile duct. We describe a method of injecting ICG directly into the gallbladder to define the cystic duct and common bile duct anatomy. A standard laparoscopic cholecystectomy was performed using a laparoscope with near-infrared imaging capability. Before dissection, the gallbladder was punctured with a cholangiogram catheter or a pigtail catheter to aspirate the bile within the gallbladder. The aspirated bile is mixed with ICG solution, which is reinjected into the gallbladder to fluoresce the gallbladder, cystic duct, and common bile duct structures. Eleven patients underwent direct gallbladder ICG injection for fluorescence cholangiography during cholecystectomy. Direct gallbladder ICG injection clearly defined the extrahepatic biliary anatomy, including the cystic duct-common bile duct junction, by fluorescence. In addition, the dissection plane between the gallbladder and the liver is highlighted with the gallbladder ICG fluorescence. Direct gallbladder ICG injection provides immediate visualization of extrahepatic biliary structures and clarifies the dissection plane between the gallbladder and the liver bed.

  7. Preliminary Full-Scale Wind-Tunnel Investigation of Wing Ducts for Radiators, Special Report

    NASA Technical Reports Server (NTRS)

    Silverstein, Abe; Nickle, F. R.

    1938-01-01

    Wing ducts for liquid-cooled engine radiators have been investigated in the N.A.C.A. full-scale wind tunnel on a large model airplane. Th e tests were made to determine the relative merits of several types of duct and radiator installations for an airplane of a particular des ign. In the test program the principal duct dimensions were system atically varied, and the results are therefore somewhat applicable to the general problems of wing duct design, although they should be co nsidered as preliminary and only indicative of the inherent possibil ities.

  8. Management of intraductal papillary mucinous neoplasms.

    PubMed

    Crippa, Stefano; Fernández-del Castillo, Carlos

    2008-04-01

    Intraductal papillary mucinous neoplasms (IPMNs) of the pancreas are being diagnosed with increasing frequency, probably due to the widespread use of cross-sectional imaging. The natural history of these tumors is still largely unknown. Several studies have shown topographical as well as biological differences between main duct and branch duct IPMNs. In the past few years, diagnostic work-up and, in particular, management of these tumors have evolved significantly. Data support the need for resection of main duct IPMNs and the possibility of nonoperative management in selected cases of branch duct tumors. In this systematic review, we analyze the most recent publications related to IPMNs, with particular emphasis on problems related to managing this challenging disease.

  9. Reconstruction of Bile Duct Injury and Defect with the Round Ligament.

    PubMed

    Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier

    2017-09-01

    Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.

  10. Application of "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy for normal soft pancreas cases.

    PubMed

    Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun

    2013-01-01

    Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new "papillary-like main pancreatic duct invaginated" techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the "papillary-like main pancreatic duct invaginated" group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the "papillary-like main pancreatic duct invaginated" group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas.

  11. Design and evaluation of a low nitrogen oxides natural gas-fired conical wire-mesh duct burner for a micro-cogeneration unit

    NASA Astrophysics Data System (ADS)

    Ramadan, Omar Barka Ab

    A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across the duct burner. A considerable amount of detailed parametric experimental data was collected to investigate the performance characteristics of the duct burner. The variables studied (firing rate, mass flow ratio, conical burner pressure drop, blockage ratio, conical burner shield length, premixer geometry and inlet conditions) were all found to play an important role on emissions (NOx and CO), overall duct burner pressure drop and flame stability. The range of firing rates at which surface combustion was maintained for the duct burner was defined by direct observation of the burner surface and monitoring of the temperature in the combustion zone. Flame images were captured for qualitative assessment. The combustion tests results presented in this thesis proved that the design procedures that were implemented to design this novel microturbine conical wire-mesh duct burner were successful. During the course of the combustion tests, the duct burner displayed stable, low emissions operation throughout the surface firing rate range of 148 kW to 328 kW (1574 kW/m 2 to 3489 kW/m2). Emissions of less than 5 ppm (corrected to 15 percent 02) for NOx and CO emissions were recorded, while the duct burner successfully raised the microturbine exhaust gases temperature from about 227°C to as high as 700°C. The overall duct burner pressure drop throughout was consistently below the design limit of 249 Pa.

  12. Analysis of the sound field in finite length infinite baffled cylindrical ducts with vibrating walls of finite impedance.

    PubMed

    Shao, Wei; Mechefske, Chris K

    2005-04-01

    This paper describes an analytical model of finite cylindrical ducts with infinite flanges. This model is used to investigate the sound radiation characteristics of the gradient coil system of a magnetic resonance imaging (MRI) scanner. The sound field in the duct satisfies both the boundary conditions at the wall and at the open ends. The vibrating cylindrical wall of the duct is assumed to be the only sound source. Different acoustic conditions for the wall (rigid and absorptive) are used in the simulations. The wave reflection phenomenon at the open ends of the finite duct is described by general radiation impedance. The analytical model is validated by the comparison with its counterpart in a commercial code based on the boundary element method (BEM). The analytical model shows significant advantages over the BEM model with better numerical efficiency and a direct relation between the design parameters and the sound field inside the duct.

  13. Granular Cell Tumor of the Common Hepatic Duct as an Unusual Cause of Jaundice in a Hepatitis C Patient.

    PubMed

    Chopade, Tripti R; Smith, Colin L; Maley, Warren R; Siddiqui, Ali A; Sass, David A

    2016-01-01

    A 33-year-old woman with a history of intravenous cocaine abuse presented with fatigue, nausea, and jaundice. Serologic testing revealed a positive hepatitis C virus (HCV) antibody and HCV RNA. Ultrasound and magnetic resonance imaging/magnetic resonance cholangiopancreatography showed a partially obstructing lesion in the common hepatic duct, which was confirmed by endoscopic retrograde cholangiopancreatography. Surgical excision revealed a granular cell tumor of the common hepatic duct, with immunohistochemical staining of tumor cells positive for S-100.

  14. The incidence and location of prostatic calculi on noncontrast computed tomography images in patients with renal calculi.

    PubMed

    Balasar, Mehmet; Poyraz, Necdet; Göğer, Yunus Emre; Unal, Yunus; Pişkin, Mehmet Mesut

    2015-08-01

    In this study, the incidence and location of prostatic calculi on noncontrast abdominal computed tomography (NCACT) images of patients with and without renal stones were investigated. Between 2006 and 2013, NCACT images were taken of 133 patients treated for renal stones (Group I) and of 100 age-matched control patients with putative urinary stone disease (Group II) in our clinic. The incidence and location of prostatic calculi on these images were determined. The location of prostatic calculus was classified as type A if they were located in the main prostatic ducts, and type B if they were located outside the ducts. Prostatic calculi were present in 44.4% of patients in Group I and 21.0% of patients in Group II. The incidence of prostatic calculi was significantly higher in patients with urinary stones compared with those without (P<0.001). The location of prostatic calculi in Group I included 74.6% type A and 25.4% type B while in Group II the locations were 76.2% type A and 23.8% type B. The incidence of prostatic calculi is more prevalent in patients with renal stones. On NCACT images, prostatic calculi were mostly detected in the main prostatic ducts, which were defined as type A.

  15. Intraductal papillary neoplasm of the bile duct: a case report.

    PubMed

    Peeters, Karen; Delvaux, Peter; Huysentruyt, Frederik

    2017-08-01

    Intraductal papillary neoplasm of the bile duct (IPNB) is a rare variant of bile duct tumors, characterized by papillary growth within the bile duct lumen and is regarded as a biliary counterpart of intraductal papillary mucinous neoplasm (IPMN) of the pancreas. IPNBs are mainly found in patients from Far Eastern areas, where hepatolithiasis and clonorchiasis are endemic. The Western experience, however, remains limited. In this article, we report a 56-year-old man, referred to our hospital because of deranged liver function tests. Further imaging modalities showed a cystic lesion of 9 cm diameter, arising from the left hepatic duct. Inlying was a heterogeneous, lobulated mass. The patient underwent a left hemihepatectomy and adjuvant chemotherapy. Despite recent advanced technologies, diagnosis of IPNB is still challenging, especially in western countries due to its rarity. Early identification and resection of lesions, even in asymptomatic or minimally symptomatic patients, are however important prognostic factors.

  16. A study of internal drag of small-scale ducts at Mach number 4

    NASA Technical Reports Server (NTRS)

    Graham, L. A.; Hunton, L. W.

    1972-01-01

    An experimental investigation was made to examine the applicability of methods used to determine internal drag of small ducts and to study some of the problems encountered in assessing momentum losses in such ducts. Test Mach numbers ranged from 3.7 to 4.4 at angles of attack of 0 and 5 degrees and at a constant Reynolds number of 4.3 million per foot. The configurations represented small ducts used to simulate external aerodynamics of air breathing propulsion systems and consisted of wing nacelle models of ducts with circular, square, and rectangular inlets and with a two-dimensional inlet.

  17. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values <0.05. The correlation of remKICG and remKGSA with posthepatectomy mortality and morbidity was determined. Although remKICG and remKGSA were not significantly different (median value: 0.071 vs 0.075), functional rates of future remnant liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P < .001). Hepatectomy was considered unsafe in 17% and 0% of patients using remKICG and remKGSA, respectively. Postoperative liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Integrated OCT-US catheter for detection of cancer in the gastrointestinal tract

    NASA Astrophysics Data System (ADS)

    Li, Jiawen; Ma, Teng; Cummins, Thomas; Shung, K. Kirk; Van Dam, Jacques; Zhou, Qifa; Chen, Zhongping

    2015-03-01

    Gastrointestinal tract cancer, the most common type of cancer, has a very low survival rate, especially for pancreatic cancer (five year survival rate of 5%) and bile duct cancer (five year survival rate of 12%). Here, we propose to use an integrated OCT-US catheter for cancer detection. OCT is targeted to acquire detailed information, such as dysplasia and neoplasia, for early detection of tumors. US is used for staging cancers according to the size of the primary tumor and whether or not it has invaded lymph nodes and other parts of the body. Considering the lumen size of the GI tract, an OCT system with a long image range (>10mm) and a US imaging system with a center frequency at 40MHz (penetration depth > 5mm) were used. The OCT probe was also designed for long-range imaging. The side-view OCT and US probes were sealed inside one probe cap piece and one torque coil and became an integrated probe. This probe was then inserted into a catheter sheath which fits in the channel of a duodenoscope and is able to be navigated smoothly into the bile duct by the elevator of the duodenoscope. We have imaged 5 healthy and 2 diseased bile ducts. In the OCT images, disorganized layer structures and heterogeneous regions demonstrated the existence of tumors. Micro-calcification can be observed in the corresponding US images.

  19. 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors.

    PubMed

    Cai, Larry; Yeh, Benjamin M; Westphalen, Antonio C; Roberts, John; Wang, Zhen J

    2017-03-01

    To investigate whether the addition of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced 3D T1-weighted MR cholangiography (T1w-MRC) to 3D T2-weighted MRC (T2w-MRC) improves the confidence and diagnostic accuracy of biliary anatomy in living liver donors. Two abdominal radiologists retrospectively and independently reviewed pre-operative MR studies in 58 consecutive living liver donors. The second-order bile duct visualization on T1w- and T2w-MRC images was rated on a 4-point scale. The readers also independently recorded the biliary anatomy and their diagnostic confidence using (1) combined T1w- and T2w-MRC, and (2) T2w-MRC. In the 23 right lobe donors, the biliary anatomy at imaging and the imaging-predicted number of duct orifices at surgery were compared to intra-operative findings. T1w-MRC had a higher proportion of excellent visualization than T2w-MRC, 66% vs. 45% for reader 1 and 60% vs. 31% for reader 2. The median confidence score for biliary anatomy diagnosis was significantly higher with combined T1w- and T2w-MRC than T2w-MRC alone for both readers (Reader 1: 3 vs. 2, p < 0.001; Reader 2: 3 vs. 1, p < 0.001). Compared to intra-operative findings, the accuracy of imaging-predicted number of duct orifices using combined T1w-and T2w-MRC was significantly higher than that using T2w-MRC alone (p = 0.034 for reader 1, p = 0.0082 for reader 2). The addition of Gd-EOB-DTPA-enhanced 3D T1w-MRC to 3D T2w-MRC improves second-order bile duct visualization and increases the confidence in biliary anatomy diagnosis and the accuracy in the imaging-predicted number of duct orifices acquired during right lobe harvesting.

  20. Application of “Papillary-Like Main Pancreatic Duct Invaginated” Pancreaticojejunostomy for Normal Soft Pancreas Cases

    PubMed Central

    Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun

    2013-01-01

    Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new “papillary-like main pancreatic duct invaginated” techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the “papillary-like main pancreatic duct invaginated” group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the “papillary-like main pancreatic duct invaginated” group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas. PMID:23797701

  1. Correlations for heat transfer coefficient and friction factor for turbulent flow of air through square and hexagonal ducts with twisted tape insert

    NASA Astrophysics Data System (ADS)

    Yadav, Rupesh J.; Kore, Sandeep S.; Joshi, Prathamesh S.

    2018-05-01

    The experimental and numerical Nusselt number and friction factor investigation for turbulent flow through a non-circular duct with twisted-tape inserts have been presented. The non-circular ducts include square, hexagonal duct. The results of non-circular ducts are compared with circular duct. All the ducts have same equivalent diameter. The twist ratios used for the experiment are Y = 3.5, 4.5, 5.5 and 6.5. Experiments were carried out on square duct, hexagonal duct and circular duct. The Reynolds number lied between 10,000 and 1, 05,000. The present study is restricted to the flow of air at Pr = 0.7 only and within a narrow temperature range of 40 to 75 ΟC, within which the compressible nature of air can be neglected. The results reveal that, both Nusselt number and friction factor increases as the side of non-circular duct increases. Maximum Nusselt number and friction factor is obtained in case of circular duct with twisted tape. Further the correlations of Nu and f are given for different non circular duct with twisted tape insert for engineering applications for the turbulent regime. Since the thermal performance factor (η) is observed to be within the range of 0.8 to 1.13 for both circular and noncircular ducts, the overall benefit of using twisted tape in the flow field shall nevertheless be marginal.

  2. Fluorescent Imaging With Indocyanine Green During Laparoscopic Cholecystectomy in Patients at Increased Risk of Bile Duct Injury

    PubMed Central

    Ankersmit, Marjolein; van Dam, Dieuwertje A.; van Rijswijk, Anne-Sophie; van den Heuvel, Baukje; Tuynman, Jurriaan B.; Meijerink, Wilhelmus J. H. J.

    2017-01-01

    Background. Although rare, injury to the common bile duct (CBD) during laparoscopic cholecystectomy (LC) can be reduced by better intraoperative visualization of the cystic duct (CD) and CBD. The aim of this study was to establish the efficacy of early visualization of the CD and the added value of CBD identification, using near-infrared (NIR) light and the fluorescent agent indocyanine green (ICG), in patients at increased risk of bile duct injury. Materials and Methods. Patients diagnosed with complicated cholecystitis and scheduled for LC were included. The CBD and CD were visualized with NIR light before and during dissection of the liver hilus and at critical view of safety (CVS). Results. Of the 20 patients originally included, 2 were later excluded due to conversion. In 6 of 18 patients, the CD was visualized early during dissection and prior to imaging with conventional white light. The CBD was additionally visualized with ICG-NIR in 7 of 18 patients. In 1 patient, conversion was prevented due to detection of the CD and CBD with ICG-NIR. Conclusions. Early visualization of the CD or additional identification of the CBD using ICG-NIR in patients with complicated cholecystolithiasis can be helpful in preventing CBD injury. Future studies should attempt to establish the optimal dosage and time frame for ICG administration and bile duct visualization with respect to different gallbladder pathologies. PMID:28178882

  3. Modeling of field-aligned guided echoes in the plasmasphere

    NASA Astrophysics Data System (ADS)

    Fung, Shing F.; Green, James L.

    2005-01-01

    Ray tracing modeling is used to investigate the plasma conditions under which high-frequency (f ≫ fuh) extraordinary mode waves can be guided along geomagnetic field lines. These guided signals have often been observed as long-range discrete echoes in the plasmasphere by the Radio Plasma Imager (RPI) onboard the Imager for Magnetopause-to-Aurora Global Exploration satellite. Field-aligned discrete echoes are most commonly observed by RPI in the plasmasphere, although they are also observed over the polar cap region. The plasmasphere field-aligned echoes appearing as multiple echo traces at different virtual ranges are attributed to signals reflected successively between conjugate hemispheres that propagate along or nearly along closed geomagnetic field lines. The ray tracing simulations show that field-aligned ducts with as little as 1% density perturbations (depletions) and <10 wavelengths wide can guide nearly field-aligned propagating high-frequency X mode waves. Effective guidance of a wave at a given frequency and wave normal angle (Ψ) depends on the cross-field density scale of the duct, such that ducts with stronger density depletions need to be wider in order to maintain the same gradient of refractive index across the magnetic field. While signal guidance by field aligned density gradient without ducting is possible only over the polar region, conjugate field-aligned echoes that have traversed through the equatorial region are most likely guided by ducting.

  4. Intrahepatic bile duct adenoma in a patient with chronic hepatitis B accompanied by elevation of alpha-fetoprotein.

    PubMed

    Ahn, Jem Ma; Paik, Yong-Han; Lee, Jun Hee; Cho, Ju Yeon; Sohn, Won; Gwak, Geum-Youn; Choi, Moon Seok; Lee, Joon Hyeok; Koh, Kwang Cheol; Paik, Seung Woon; Yoo, Byung Chul

    2015-12-01

    A 51-year-old male patient with chronic hepatitis B was referred to our hospital due to a 1-cm liver nodule on ultrasonography. Alpha-fetoprotein (AFP) was slightly elevated. The nodule showed prolonged enhancement on dynamic liver magnetic resonance imaging and appeared as a hyperintensity on both diffusion-weighted and T2-weighted imaging. The nodule was followed up because it was small and typical findings of hepatocellular carcinoma (HCC) were not observed in the dynamic imaging investigations. However, liver contrast-enhanced ultrasonography performed 1 month later showed enhancement during the arterial phase and definite washout during the delayed phase. Also, AFP had increased to over 200 ng/mL even though AST and ALT were decreased after administering an antiviral agent. He was presumptively diagnosed as HCC and underwent liver segmentectomy. Microscopy findings of the specimen indicated bile duct adenoma. After resection, the follow-up AFP had decreased to within the normal range. This patient represents a case of bile duct adenoma with AFP elevation mimicking HCC on contrast-enhanced ultrasonography.

  5. Sound propagation in a duct of periodic wall structure. [numerical analysis

    NASA Technical Reports Server (NTRS)

    Kurze, U.

    1978-01-01

    A boundary condition, which accounts for the coupling in the sections behind the duct boundary, is given for the sound-absorbing duct with a periodic structure of the wall lining and using regular partition walls. The soundfield in the duct is suitably described by the method of differences. For locally active walls this renders an explicit approximate solution for the propagation constant. Coupling may be accounted for by the method of differences in a clear manner. Numerical results agree with measurements and yield information which has technical applications.

  6. SSME 3-D Turnaround Duct flow analysis - CFD predictions

    NASA Technical Reports Server (NTRS)

    Brankovic, Andreja; Stowers, Steven T.; Mcconnaughey, Paul

    1988-01-01

    CFD analysis is presently employed to obtain an improved flowfield for an individual flowpath in the case of the Space Shuttle Main Engine's High Pressure Fuel Turbopump Turn-Around Duct (TAD), which conducts the flow exiting from the gas turbines into the fuel bowl. It is demonstrated that the application of CFD to TAD flow analysis, giving attention to the duct's configuration and to the number, shape, and alignment of the diffuser struts, can enhance understanding of flow physics and result in improved duct design and performance.

  7. Study on Pressure Wave Propagation in a Liquid Containing Spherical Bubbles in a Rectangular Duct

    NASA Astrophysics Data System (ADS)

    Kawahara, Junya; Watanabe, Masao; Kobayashi, Kazumichi

    2015-12-01

    Pressure wave propagation in a liquid containing several bubbles is numerically investigated. We simulate liner plane wave propagation in a liquid containing 10 spherical bubbles in a rectangular duct with the equation of motion for N spherical bubbles. The sound pressures of the reflected waves from the rigid walls are calculated by using the method of images. The result shows that the phase velocity of the pressure wave propagating in the liquid containing 10 spherical bubbles in the duct agrees well with the low-frequency speed of sound in a homogeneous bubbly liquid.

  8. Post-cholecystectomy syndrome: spectrum of biliary findings at magnetic resonance cholangiopancreatography

    PubMed Central

    Girometti, R; Brondani, G; Cereser, L; Como, G; Del Pin, M; Bazzocchi, M; Zuiani, C

    2010-01-01

    Post-cholecystectomy syndrome (PCS) is defined as a complex of heterogeneous symptoms, consisting of upper abdominal pain and dyspepsia, which recur and/or persist after cholecystectomy. Nevertheless, this term is inaccurate, as it encompasses biliary and non-biliary disorders, possibly unrelated to cholecystectomy. Biliary manifestations of PCS may occur early in the post-operative period, usually because of incomplete surgery (retained calculi in the cystic duct remnant or in the common bile duct) or operative complications, such as bile duct injury and/or bile leakage. A later onset is commonly caused by inflammatory scarring strictures involving the sphincter of Oddi or the common bile duct, recurrent calculi or biliary dyskinesia. The traditional imaging approach for PCS has involved ultrasound and/or CT followed by direct cholangiography, whereas manometry of the sphincter of Oddi and biliary scintigraphy have been reserved for cases of biliary dyskinesia. Because of its capability to provide non-invasive high-quality visualisation of the biliary tract, magnetic resonance cholangiopancreatography (MRCP) has been advocated as a reliable imaging tool for assessing patients with suspected PCS and for guiding management decisions. This paper illustrates the rationale for using MRCP, together with the main MRCP biliary findings and diagnostic pitfalls. PMID:20335441

  9. Fluorescence-based microendoscopes for breast cancer ductoscopy

    NASA Astrophysics Data System (ADS)

    Zeylikovich, Iosif; Tang, Guichen C.; Katz, A.; Budansky, Yury; Alfano, R. R.

    2006-02-01

    Recently microendoscopes are being developed as a tool to detection cancer or pre-cancerous lesions in the milk ducts of the human breast. The microendoscope can be inserted into the duct through the nipple. Integration of fluorescence spectroscopy into microendoscopy can provide an improved platform for real-time cancer detection followed by immediate intervention. Typically, the optical fibers employed by existing microendoscope systems transmit in the 450 to 900 nm range. A prototype system combining fluorescence spectroscopy with visible imaging by microendoscopy is described and preliminary measurements on ex vivo human breast tissues are presented. Image resolution and distortion are discussed.

  10. Lesions of the segmental and lobar hepatic ducts.

    PubMed Central

    Longmire, W P; Tompkins, R K

    1975-01-01

    Despite reports to the contrary, unobstructed drainage of 50% of an otherwise normal liver through either the right or left uninfected hepatic duct is adequate to restore normal liver function, even if the obstructed lobe remains in place. An undrained liver lobe, if present, may require no further treatment. As long as it is completely obstructed and uninfected, it will undergo a progressive asymptomatic atrophy. Cholangitis invariably develops behind a partial lobar ductal obstruction, producing jaundice, pruritis, and fever. Unless unobstructed, uninfected biliary flow can be achieved through a segmental or lobar duct, it is better that the duct be completely obstructed and the affected liver parenchyma allowed to atrophy, provided there is normal biliary flow from the residual 50% of liver. This concept is important in the management of injured anomalous segmental or lobar hepatic duct and in the palliative treatment of bile duct carcinoma. Localized intrahepatic infections communicating with abnormal biliary ducts will require hepatic resection of the infected parenchyma and ducts for cure. The abnormality may be saccular dilatation of the intrahepatic ductal system with abscess formation or intrahepatic abscess associated with stenosis of the ductal system from trauma to the duct, to the duct and liver, or to retained intrahepatic stones. Diffusely situated intrahepatic abscesses secondary to ductal abnormalities can be treated with systemic antibiotics, local drainage of a dmoninant abscess, and efforts to improve biliary drainage. Images Fig. 4. Fig. 5. Fig. 6. Fig. 8. Fig. 9. Fig. 10. Figs. 11A and B Figs. 12A and B. Fig. 13. Fig. 14. Fig. 15. Fig. 16. Fig. 17. PMID:1180585

  11. Pancreatic duct stenosis: Differential diagnosis between malignant and benign conditions at secretin-enhanced MRCP.

    PubMed

    Boninsegna, Enrico; Manfredi, Riccardo; Negrelli, Riccardo; Avesani, Giacomo; Mehrabi, Sara; Pozzi Mucelli, Roberto

    To define imaging criteria of benign and malignant nature in patients with main pancreatic duct (MPD) stenosis. S-MRCPs of 35 patients with pancreatitis and 14 with adenocarcinoma were evaluated. Adenocarcinoma caused higher prevalence of complete stenosis (14/14-100% vs 17/35-49%), dilated side-branches (14/14-100% vs 18/35-51%) and lower prevalence of duct-penetrating sign (0/14-0% vs 31/35-89%). The number of stenoses was higher in benign conditions (mean 1.4 Vs 1). Upstream MPD diameter was higher in cancer-induced stenoses (4.5 vs 2.9mm). Single complete stenosis with dilated side branches, increased MPD caliber and absent duct-penetrating sign are suggestive of malignancy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Evaluation of several non-reflecting computational boundary conditions for duct acoustics

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Zorumski, William E.; Hodge, Steve L.

    1994-01-01

    Several non-reflecting computational boundary conditions that meet certain criteria and have potential applications to duct acoustics are evaluated for their effectiveness. The same interior solution scheme, grid, and order of approximation are used to evaluate each condition. Sparse matrix solution techniques are applied to solve the matrix equation resulting from the discretization. Modal series solutions for the sound attenuation in an infinite duct are used to evaluate the accuracy of each non-reflecting boundary conditions. The evaluations are performed for sound propagation in a softwall duct, for several sources, sound frequencies, and duct lengths. It is shown that a recently developed nonlocal boundary condition leads to sound attenuation predictions considerably more accurate for short ducts. This leads to a substantial reduction in the number of grid points when compared to other non-reflecting conditions.

  13. Stepwise approach to curative surgery using percutaneous transhepatic cholangiodrainage and portal vein embolization for severe bile duct injury during laparoscopic cholecystectomy: a case report.

    PubMed

    Honmyo, Naruhiko; Kuroda, Shintaro; Kobayashi, Tsuyoshi; Ishiyama, Kohei; Ide, Kentaro; Tahara, Hiroyuki; Ohira, Masahiro; Ohdan, Hideki

    2016-12-01

    Laparoscopic cholecystectomy (LC) has been recently adapted to acute cholecystitis. Major bile duct injury during LC, especially Strasberg-Bismuth classification type E, can be a critical problem sometimes requiring hepatectomy. Safety and definitive treatment without further morbidities, such as posthepatectomy liver failure, is required. Here, we report a case of severe bile duct injury treated with a stepwise approach using (99m)Tc-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging to accurately estimate liver function.A 52-year-old woman diagnosed with acute cholecystitis underwent LC at another hospital and was transferred to our university hospital for persistent bile leakage on postoperative day 20. She had no jaundice or infection, although an intraperitoneal drainage tube discharged approximately 500 ml of bile per day. Recorded operation procedure showed removal of the gallbladder with a part of the common bile duct due to its misidentification, and each of the hepatic ducts and right hepatic artery was injured. Abdominal enhanced CT revealed obstructive jaundice of the left liver and arterial shunt through the hilar plate to the right liver. Magnetic resonance cholangiopancreatography revealed type E4 or more advanced bile duct injury according to the Bismuth-Strasberg classification. We planned a stepwise approach using percutaneous transhepatic cholangiodrainage (PTCD) and portal vein embolization (PVE) for secure right hemihepatectomy and biliary-jejunum reconstruction and employed (99m)Tc-GSA SPECT/CT fusion imaging to estimate future remnant liver function. The left liver function rate had changed from 26.2 % on admission to 26.3 % after PTCD and 54.5 % after PVE, while the left liver volume rate was 33.8, 33.3, and 49.6 %, respectively. The increase of liver function was higher than that of volume (28.3 vs. 15.8 %). On postoperative day 63, the curative operation, right hemihepatectomy and biliary-jejunum reconstruction, was performed, and posthepatectomy liver failure could be avoided.Careful consideration of treatment strategy for each case is necessary for severe bile duct injury with arterial injury requiring hepatectomy. The stepwise approach using PTCD and PVE could enable hemihepatectomy, and (99m)Tc-GSA SPECT/CT fusion imaging was useful to estimate heterogeneous liver function.

  14. Finding Infrastructure with Non-Destructive Imaging Technologies (FINDIT)

    NASA Astrophysics Data System (ADS)

    Tuckwell, G.; Usher, C.; Stringfellow, M.; Chapman, D.; Metje, N.; Roberts, D.

    2017-12-01

    Novel uses for existing technologies and new post-processing techniques have been developed to generate a level and detail of information that will make a step-change to standard practice in mapping and assessing the condition of buried infrastructure. The most appropriate sensing technologies for buried telecommunications ducts have been identified as Ground Penetrating Radar and Acoustic reflectometry. Dielectric permittivity changes in the near-surface can manifest themselves in different ways within GPR data. Numerical modelling work has been undertaken by applying a Kuepper signal and an exploding source, and using various different frequencies to determine minute changes (e.g. cracks in pipes) in an object or feature within the near surface. This modelling demonstrated that there is a clear difference between an empty duct, a duct partially filled with cables and a damaged duct. This was confirmed in a laboratory test on dry sand to determine the detectability of a hole in a plastic pipe. This has formed the foundation new data processing algorithms to detect the presence of such defects in real and synthetic data sets. Future work will focus on the development of a test site and field trials to assess the detectability of defects under realistic field conditions. This ongoing programme of work will be validated and iteratively improved by field trials under controlled and live commercial conditions. Finally the cost/benefit of the new workflows develop evaluated through the development of business models for the application of such techniques in telecoms, water and energy supply sectors. In the UK, the majority of the communication network is buried in ducts which are often several decades old. They have often collapsed or become blocked so that spare capacity cannot be used. There is currently no surface detection technology which can accurately locate the position of these defects (or even accurately locate the ducts in all circumstances), so time consuming and costly manual rodding is performed which cannot detect subsequent blockages, resulting in inadequate and inefficient repair planning, increasing the costs and causing disruption to road users.

  15. Multimode-Optical-Fiber Imaging Probe

    NASA Technical Reports Server (NTRS)

    Jackson, Deborah

    2000-01-01

    Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

  16. Multimode-Optical-Fiber Imaging Probe

    NASA Technical Reports Server (NTRS)

    Jackson, Deborah

    1999-01-01

    Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).

  17. Closeup side view of Space Shuttle Main Engine (SSME) 2059 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close-up side view of Space Shuttle Main Engine (SSME) 2059 mounted in a SSME Engine Handler near the Drying Area in the High Bay section of the SSME Processing Facility. The prominent features of the SSME in this view are the hot-gas expansion nozzle extending from the approximate image center toward the image right. The main-engine components extend from the approximate image center toward image right until it meets up with the mount for the SSME Engine Handler. The engine is rotated to a position where the major components in the view are the Low-Pressure Fuel Turbopump Discharge Duct with reflective foil insulation on the upper side of the engine, the Low-Pressure Oxidizer Turbopump and its Discharge Duct on the right side of the engine assembly extending itself down and wrapping under the bottom side of the assembly to the High-Pressure Oxidizer Turbopump pump. The High-Pressure Oxidizer Turbopump Discharge Duct exists the turbopump and extends up to the top side of the assembly where it enters the main oxidizer valve. The sphere on the lower side of the engine assembly is an accumulator that is part of the SSMEs POGO suppression system. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  18. Three-dimensional visualization of the microvasculature of bile duct ligation-induced liver fibrosis in rats by x-ray phase-contrast imaging computed tomography

    NASA Astrophysics Data System (ADS)

    Xuan, Ruijiao; Zhao, Xinyan; Hu, Doudou; Jian, Jianbo; Wang, Tailing; Hu, Chunhong

    2015-07-01

    X-ray phase-contrast imaging (PCI) can substantially enhance contrast, and is particularly useful in differentiating biological soft tissues with small density differences. Combined with computed tomography (CT), PCI-CT enables the acquisition of accurate microstructures inside biological samples. In this study, liver microvasculature was visualized without contrast agents in vitro with PCI-CT using liver fibrosis samples induced by bile duct ligation (BDL) in rats. The histological section examination confirmed the correspondence of CT images with the microvascular morphology of the samples. By means of the PCI-CT and three-dimensional (3D) visualization technique, 3D microvascular structures in samples from different stages of liver fibrosis were clearly revealed. Different types of blood vessels, including portal veins and hepatic veins, in addition to ductular proliferation and bile ducts, could be distinguished with good sensitivity, excellent specificity and excellent accuracy. The study showed that PCI-CT could assess the morphological changes in liver microvasculature that result from fibrosis and allow characterization of the anatomical and pathological features of the microvasculature. With further development of PCI-CT technique, it may become a novel noninvasive imaging technique for the auxiliary analysis of liver fibrosis.

  19. [Single shot fast spin echo sequence MRI cholangiopancreatography].

    PubMed

    Lefèvre, F; Crouzet, P; Gaucher, H; Chapuis, F; Béot, S; Boccaccini, H; Bazin, C; Régent, D

    1998-05-01

    To assess the value of single shot fast spin echo MR sequence (SS-FSE) in the morphological analysis of the biliary tree and pancreatic ducts and to compare its accuracy with other imaging methods. 95 consecutive patients referred for clinical and/or biological suspicion of biliary obstruction were explored with MR cholangiopancreatography (MRCP). All patients were explored with a Signa 1.5 T GE MR unit, with High Gradient Field Strength and Torso Phased Array Coil. Biliary ducts were explored with SS-FSE sequence, coronal and oblique coronal 20 mm thick slices on a 256 x 256 matrix. Total acquisition time was 1 second. Native pictures were reviewed by two radiologists blinded to clinical information. In case of disagreement, a third radiologist's judgement was requested. In 88 cases, MRCP results were compared with direct biligraphy methods. In all cases, MRCP produced high quality images without MIP or other post-processing methods. For detection of biliary tree distensions, the concordance value of MRCP was over 91% (Kappa 0.82). For detection of biliary tree and/or pancreatic duct obstruction, MR sensitivity was 100% and specificity 91%. The overall diagnostic concordance value of MRCP was > or = 93%. Difficulties in MRCP were caused by functional diseases or benign stenosis. MRCP accurately diagnosed all lithiasic obstructions starting from a stone size of 3 mm. MRCP produces fastly high-quality images. As it is totally safe, it can be proposed as a first intention method in biliopancreatic duct explorations.

  20. Voluntary and involuntary ligature of the bile duct in iatrogenic injuries: a nonadvisable approach.

    PubMed

    Mercado, Miguel Angel; Chan, Carlos; Jacinto, Juan Carlos; Sanchez, Norberto; Barajas, Alexandra

    2008-06-01

    Bile duct injuries related to laparoscopic and/or open cholecystectomy are a frequent finding and require surgical treatment. Complete obstruction is due to either intentionally or unintentionally placed ligatures or clips. The intentional application is usually performed to "facilitate identification of the duct by bile duct dilation." Considering that we are a national referral center for such injuries, we decided to analyze our cases of voluntary and involuntary duct ligation after iatrogenic bile duct injury. We reviewed the files of patients with voluntary or involuntary bile duct ligation. Results of preoperative evaluation of the ducts, operative treatment, and postoperative results were analyzed. A total of 413 patients were included. Forty-five patients presented with complete obstruction. In 15 cases, the ligature was intentional, and in 30 cases, occlusion was involuntary. Bile duct dilation (>10 mm) was demonstrated in one case of voluntary (6%) and three cases of involuntary ligations (10%). The remaining cases in both groups had no duct dilation and developed necrosis at the blinded duct and leakage proximal to the ligature, with different degrees of bilioperitoneum and/or biloma. In all cases, a Roux-en-Y hepatojejunostomy was performed. Bile duct ligature produces dilation in a very small number of patients (less than 10%) and usually produces necrosis of the blinded stump with subsequent bile leakage. Placement of a subhepatic drain and transference of the patient to a qualified center for reconstruction is the best approach if the primary surgeon is not able to do the repair.

  1. Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sweet, M. L.; Francisco, A.; Roberts, S. G.

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less

  2. Effect of relative humidity on fungal colonization of fiberglass insulation.

    PubMed Central

    Ezeonu, I M; Noble, J A; Simmons, R B; Price, D L; Crow, S A; Ahearn, D G

    1994-01-01

    Fiberglass duct liners and fiberglass duct boards from eight buildings whose occupants complained of unacceptable or moldy odors in the air were found to be heavily colonized by fungi, particularly by Aspergillus versicolor. Unused fiberglass was found to be susceptible to fungal colonization in environmental chambers dependent upon relative humidity. No colonization was observed at relative humidities below 50%. Images PMID:8031101

  3. Clinicopathological Features of Intraductal Pancreatic Neuroendocrine Tumors.

    PubMed

    Chang, Xiao-Yan; Jia, Cong-Wei; Meng, Yun-Xiao; Chen, Jie

    2016-10-10

    Objective To evaluate the clinical and pathologic characteristics of intraductal pancreatic neuroendocrine tumors (PanNETs). Methods Four cases of intraductal PanNETs were studied by light microscopy and immunohistochemistry with the analysis of morphologic features and review of relevant literatures. Results Two female patients and two male patients aged 41- 58 years were enrolled in this study. The chief complaint was abdominal pain in two patients,vomiting in one patient,and jaundice in the last patient. Imaging examination showed intraductal neoplasm with diagnosis as intraductal papillary mucinous neoplasm (IPMN) in case 1; space-occupying lesions were found in the head of pancreas in the other three cases with pancreatic ductal ectasia and distal pancreatic atrophy. Grossly the masses were located in pancreatic main duct and invaded into surrounding pancreatic parachyma. Microscopically the tumors arranged with solid pattern,with some trabecular structures in the last two cases. Small duct and ductules were seen in intraductal PanNETs. The immunohistochemical expression showed that SYN and CgA were positive in neoplastic cells and negative in small duct and ductules.Conclusions Intraductal PanNETs are rare conditions. The clinical symptoms and imaging findings are similar to IPMN or pancreatic carcinoma. The tumors are located within pancreatic duct partly and can invade the pancreatic parenchyma. Microscopically the neuroendocrine tumors mix with small duct and forms ductulo-insular structure,which should be differentiated with mixed ductal endocrine carcinoma. The grade and prognosis are similar to those of classical neuroendocrine tumors.

  4. Refraction-based X-ray Computed Tomography for Biomedical Purpose Using Dark Field Imaging Method

    NASA Astrophysics Data System (ADS)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Huo, Qingkai; Ichihara, Shu; Ando, Masami

    We have proposed a tomographic x-ray imaging system using DFI (dark field imaging) optics along with a data-processing method to extract information on refraction from the measured intensities, and a reconstruction algorithm to reconstruct a refractive-index field from the projections generated from the extracted refraction information. The DFI imaging system consists of a tandem optical system of Bragg- and Laue-case crystals, a positioning device system for a sample, and two CCD (charge coupled device) cameras. Then, we developed a software code to simulate the data-acquisition, data-processing, and reconstruction methods to investigate the feasibility of the proposed methods. Finally, in order to demonstrate its efficacy, we imaged a sample with DCIS (ductal carcinoma in situ) excised from a breast cancer patient using a system constructed at the vertical wiggler beamline BL-14C in KEK-PF. Its CT images depicted a variety of fine histological structures, such as milk ducts, duct walls, secretions, adipose and fibrous tissue. They correlate well with histological sections.

  5. Small intestinal obstruction by remnants of the omphalomesenteric duct: findings on contrast enema.

    PubMed

    Fenton, L Z; Buonomo, C; Share, J C; Chung, T

    2000-03-01

    We reviewed the contrast enema examinations and medical records of six patients with small intestinal obstruction due to omphalomesenteric duct remnant to evaluate for characteristic imaging findings. In five out of the six patients the point of obstruction was demonstrated on the enema; in three patients, the characteristic "beak" of a volvulus was seen, either in the terminal ileum or cecum. In three patients, there was medial deviation of the cecum. The characteristic radiographic features of volvulus at the cecum or terminal ileum and medial deviation of the cecum should suggest persistence of an omphalomesenteric duct remnant as the etiology of obstruction in a child less than 2 years of age. The appearance of omphalomesenteric duct remnant obstruction on enema examination, though not specific, is characteristic and should be familiar to pediatric radiologists.

  6. CFD-Based Design of Turbopump Inlet Duct for Reduced Dynamic Loads

    NASA Technical Reports Server (NTRS)

    Rothermel, Jeffry; Dorney, Suzanne M.; Dorney, Daniel J.

    2003-01-01

    Numerical simulations have been completed for a variety of designs for a 90 deg elbow duct. The objective is to identify a design that minimizes the dynamic load entering a LOX turbopump located at the elbow exit. Designs simulated to date indicate that simpler duct geometries result in lower losses. Benchmark simulations have verified that the compressible flow codes used in this study are applicable to these incompressible flow simulations.

  7. CFD-based Design of LOX Pump Inlet Duct for Reduced Dynamic Loads

    NASA Technical Reports Server (NTRS)

    Rothermel, Jeffry; Dorney, Daniel J.; Dorney, Suzanne M.

    2003-01-01

    Numerical simulations have been completed for a variety of designs for a 90 deg elbow duct. The objective is to identify a design that minimizes the dynamic load entering a LOX turbopump located at the elbow exit. Designs simulated to date indicate that simpler duct geometries result in lower losses. Benchmark simulations have verified that the compressible flow code used in this study is applicable to these incompressible flow simulations.

  8. The vomeronasal organ of the cat.

    PubMed Central

    Salazar, I; Sanchez Quinteiro, P; Cifuentes, J M; Garcia Caballero, T

    1996-01-01

    The vomeronasal organ of the cat was studied macroscopically, by light microscopy and by immunohistochemical techniques. Special attention was paid to the general distribution of the various soft tissue components of this organ (duct, glands, connective tissue, blood vessels and nerves.) Examination of series of transverse sections showed that the wall of the vomeronasal duct bears 44 different types of epithelium: simple columnar in the caudal part of the duct, respiratory and receptor respectively on the lateral and medial walls of the middle part of the duct, and stratified squamous rostrally. The pattern of distribution of other soft tissue components was closely associated with that of epithelium types. In areas where the duct wall was lined with receptor epithelium, nerves and connective tissue were present between the epithelium and the medial sheet of the vomeronasal cartilage. Most glands and blood vessels were located lateral to those areas of the duct wall lined with respiratory epithelium. Numerous basal cells were present in the sensory epithelium. Understanding of the distribution of the soft tissue components of this organ may shed light on its function. Images Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Figs. 13-14 PMID:8621344

  9. Tamoxifen decreases the myofibroblast count in the healing bile duct tissue of pigs

    PubMed Central

    Siqueira, Orlando Hiroshi Kiono; Filho, Benedito Herani; de Paula, Rafael Erthal; Áscoli, Fábio Otero; da Nóbrega, Antonio Cláudio Lucas; Carvalho, Angela Cristina Gouvêa; Pires, Andréa Rodrigues Cordovil; Gaglionone, Nicolle Cavalcante; Cunha, Karin Soares Gonçalves; Granjeiro, José Mauro

    2013-01-01

    OBJECTIVE: The aim of this study was to evaluate the effect of oral tamoxifen treatment on the number of myofibroblasts present during the healing process after experimental bile duct injury. METHODS: The sample consisted of 16 pigs that were divided into two groups (the control and study groups). Incisions and suturing of the bile ducts were performed in the two groups. Tamoxifen (20 mg/day) was administered only to the study group. The animals were sacrificed after 30 days. Quantification of myofibroblasts in the biliary ducts was made through immunohistochemistry analysis using anti-alpha smooth muscle actin of the smooth muscle antibody. Immunohistochemical quantification was performed using a digital image system. RESULTS: In the animals treated with tamoxifen (20 mg/day), there was a significant reduction in immunostaining for alpha smooth muscle actin compared with the control group (0.1155 vs. 0.2021, p = 0.046). CONCLUSION: Tamoxifen reduced the expression of alpha smooth muscle actin in the healing tissue after bile duct injury, suggesting a decrease in myofibroblasts in the scarred area of the pig biliary tract. These data suggest that tamoxifen could be used in the prevention of biliary tract stenosis after bile duct surgeries. PMID:23420165

  10. Catheter-based flexible microcoil RF detectors for internal magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ahmad, M. M.; Syms, R. R. A.; Young, I. R.; Mathew, B.; Casperz, W.; Taylor-Robinson, S. D.; Wadsworth, C. A.; Gedroyc, W. M. W.

    2009-07-01

    Flexible catheter probes for magnetic resonance imaging (MRI) of the bile duct are demonstrated. The probes consist of a cytology brush modified to accept a resonant RF detector based on a spiral microcoil and hybrid integrated capacitors, and are designed for insertion into the duct via a non-magnetic endoscope during endoscopic retrograde cholangiopancreatography (ERCP). The coil must be narrow enough (<3 mm) to pass through the biopsy channel of the endoscope and sufficiently flexible to turn through 90° to enter the duct. Coils are fabricated as multi-turn electroplated conductors on a flexible base, and two designs formed on SU-8 and polyimide substrates are compared. It is shown that careful control of thermal load is used to obtain useable mechanical properties from SU-8, and that polyimide/SU-8 composites offer improved mechanical reliability. Good electrical performance is demonstrated and sub-millimetre resolution is obtained in 1H MRI experiments at 1.5 T magnetic field strength using test phantoms and in vitro liver tissue.

  11. Endoscopic diagnosis of extrahepatic bile duct carcinoma: Advances and current limitations

    PubMed Central

    Tamada, Kiichi; Ushio, Jun; Sugano, Kentaro

    2011-01-01

    The accurate diagnosis of extrahepatic bile duct carcinoma is difficult, even now. When ultrasonography (US) shows dilatation of the bile duct, magnetic resonance cholangiopancreatography followed by endoscopic US (EUS) is the next step. When US or EUS shows localized bile duct wall thickening, endoscopic retrograde cholangiopancreatography should be conducted with intraductal US (IDUS) and forceps biopsy. Fluorescence in situ hybridization increases the sensitivity of brush cytology with similar specificity. In patients with papillary type bile duct carcinoma, three biopsies are sufficient. In patients with nodular or infiltrating-type bile duct carcinoma, multiple biopsies are warranted, and IDUS can compensate for the limitations of biopsies. In preoperative staging, the combination of dynamic multi-detector low computed tomography (MDCT) and IDUS is useful for evaluating vascular invasion and cancer depth infiltration. However, assessment of lymph nodes metastases is difficult. In resectable cases, assessment of longitudinal cancer spread is important. The combination of IDUS and MDCT is useful for revealing submucosal cancer extension, which is common in hilar cholangiocarcinoma. To estimate the mucosal extension, which is common in extrahepatic bile duct carcinoma, the combination of IDUS and cholangioscopy is required. The utility of current peroral cholangioscopy is limited by the maneuverability of the “baby scope”. A new baby scope (10 Fr), called “SpyGlass” has potential, if the image quality can be improved. Since extrahepatic bile duct carcinoma is common in the Far East, many researchers in Japan and Korea contributed these studies, especially, in the evaluation of longitudinal cancer extension. PMID:21611097

  12. Building America Case Study: Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4, LaFayette, Georgia (CZ4), and Savannah, Georgia (CZ2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    V. Kochkin, M. Sweet

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less

  13. Building America Case Study: Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4, LaFayette, Georgia (CZ4), and Savannah, Georgia (CZ2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-02-01

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less

  14. [Mirizzi syndrome: experience at Spanish Hospital of Veracruz].

    PubMed

    Roesch-Dietlen, Federico; Pérez-Morales, Alfonso Gerardo; Martínez-Fernández, Silvia; Remes-Troche, José María; Jiménez-García, Victoria Alejandra; Romero-Sierra, Graciela

    2013-01-01

    Mirizzi syndrome is a complication of gallbladder stones impacted in Hartmann's pouch or cystic duct with compression of the bile duct. The diagnosis is made by imaging studies, although most of them are found through intraoperative surgical findings. Treatment is cholecystectomy and bile duct restoration when needed. to analyze a series of cases of Mirizzi syndrome and compare the results with those published in the literature. We report 4 cases with Mirizzi syndrome in a cohort of 1,034 cases studied in the Hospital Español of Veracruz over 21 years. In our series the frequency of Mirizzi syndrome was 0.38%, the average age was 32.1 ± 58.4 years, 50% were male gender and 25% had jaundice with a demonstrable liver profile. In 1 case, ultrasound suggested Mirizzi syndrome and percutaneous cholangiography and computed tomography confirmed the diagnosis. All patients underwent laparoscopic cholecystectomy, and 2 transcystic cholangiographies were performed. One case was classified as Type I-A and three as type I-B. (Beltran and Csendes). The postoperative evolution was satisfactory in all and no mortality was presented. Mirizzi syndrome should be suspected in patients with gallstones who develop obstructive jaundice and it must be confirmed with imaging studies. The surgeon must take extreme precautions to avoid accidental injury to the bile ducts.

  15. Klatskin-mimicking lesions--a case series and literature review.

    PubMed

    Dumitrascu, Traian; Ionescu, Mihnea; Ciurea, Silviu; Herlea, Vlad; Lupescu, Ioana; Popescu, Irinel

    2010-01-01

    Obstruction of the hepatic hilum in patients without prior surgery is generally due to hilar adenocarcinoma (Klatskin tumor). However, not all the hilar strictures are malignant. Although uncommon, benign strictures of the proximal bile duct should be taken into consideration in differential diagnosis of Klatskin tumors, since the incidence could reach up to 25% of patients with presumed Klatskin tumor diagnosis. This group of benign proximal bile duct strictures (Klatskin-mimicking lesions) is usually represented by segmental fibrosis and non-specific chronic inflammation. The clinical and imaging features can not differentiate between benign and malignant strictures. Herein, we present a case series of three patients with benign proximal bile duct strictures (representing 4.1% of 73 patients resected with presumptive preoperative diagnosis of Klatskin tumor) and literature review. There are presented the clinical and biochemical features, imaging preoperative workup, surgical treatment and histological analysis of the specimen, along with postoperative outcome. For benign strictures of the hilum limited resections are curative. However, despite new diagnosis tools developed in the last years, patients with hilar obstructions still require unnecessary extensive resections due to impossibility of excluding the malignancy. In all cases of proximal bile duct obstruction presumed malignant, they should be managed accordingly, even with the risk of over-treatment for some benign lesions.

  16. Observed characteristics of atmospheric ducts over the South China Sea in autumn

    NASA Astrophysics Data System (ADS)

    Cheng, Yinhe; Zhou, Shengqi; Wang, Dongxiao; Lu, Yuanzheng; Huang, Ke; Yao, Jinglong; You, Xiaobao

    2016-05-01

    The observed characteristics of lower atmospheric ducts over the South China Sea (SCS) were analyzed based on Global Position Systerm (GPS) radiosonde data collected four times daily during autumn open cruises from 2006 to 2012. Duct occurrence, thickness, and strength over the SCS were about 40%, 150-m thick, and 8 M units, respectively, which were larger than during the summer monsoon period. Most ducts occurred at heights <1 500 m and these ducts easily trap electromagnetic wave clusters with wavelengths <2 m. Diurnal variation of the SCS ducts appeared evident. They occurred more often at midnight at higher altitudes (about 1 100 m), with a thickest layer of about 145 m and less frequently during the evening at lower altitudes (about 800 m), with a thinnest layer of about 125 m. Moreover, ducts during the daytime at a mean height of about 900 m, with the greatest strength of about 10 M units. Furthermore, all duct variables observed over the SCS in autumn decreased from north to south. These findings are useful not only in the design of radar and communication systems, but also for evaluating possible effects of anomalous propagation on meteorological radar and military applications.

  17. Eversion Technique to Prevent Biliary Stricture After Living Donor Liver Transplantation in the Universal Minimal Hilar Dissection Era.

    PubMed

    Ikegami, Toru; Shimagaki, Tomonari; Kawasaki, Junji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Harada, Noboru; Harimoto, Norifumi; Itoh, Shinji; Soejima, Yuji; Maehara, Yoshihiko

    2017-01-01

    Biliary anastomosis stricture (BAS) is still among the major concerns after living donor liver transplantation (LDLT), even after the technical refinements including the universal use of the blood flow-preserving hilar dissection technique. The aim of this study is to investigate what are still the factors for BAS after LDLT. An analysis of 279 adult-to-adult LDLT grafts (left lobe, n = 161; right lobe, n = 118) with duct-to-duct biliary reconstruction, since the universal application of minimal hilar dissection technique and gradual introduction of eversion technique, was performed. There were 39 patients with BAS. Univariate analysis showed that a right lobe graft (P = 0.008), multiple bile ducts (P < 0.001), ductoplasty (P < 0.001), not using the eversion technique (P = 0.004) and fewer biliary stents than bile duct orifices (P = 0.002) were among the factors associated with BAS. The 1-year and 5-year BAS survival rates were 17.7% and 21.2% in the noneversion group (n = 134), and 6.2% and 7.9% in the eversion group (n = 145), respectively (P = 0.002). The perioperative factors including graft biliary anatomy were not different between everted (n = 134) and noneverted (n = 145) patients. The application of eversion technique under minimal hilar dissection technique could be a key for preventing BAS in duct-to-duct biliary reconstruction in LDLT.

  18. Review of the Rhein-Flugzeugbau Wankel powered aircraft program. [ducted fan engines

    NASA Technical Reports Server (NTRS)

    Riethmueller, M.

    1978-01-01

    The development of light aircraft with special emphasis on modern propulsion systems and production is discussed in terms of the application of rotary engines to aircraft. Emphasis is placed on the integrated ducted-fan propulsion system using rotary engines.

  19. Noise Attenuation Performance of a Helmholtz Resonator Array Consist of Several Periodic Parts

    PubMed Central

    Wu, Dizi; Zhang, Nan; Mak, Cheuk Ming; Cai, Chenzhi

    2017-01-01

    The acoustic performance of the ducted Helmholtz resonator (HR) system is analyzed theoretically and numerically. The periodic HR array could provide a wider noise attenuation band due to the coupling of the Bragg reflection and the HR’s resonance. However, the transmission loss achieved by a periodic HR array is mainly dependent on the number of HRs, which restricted by the available space in the longitudinal direction of the duct. The full distance along the longitudinal direction of the duct for HR’s installation is sometimes unavailable in practical applications. Only several pieces of the duct may be available for the installation. It is therefore that this paper concentrates on the acoustic performance of a HR array consisting of several periodic parts. The transfer matrix method and the Bragg theory are used to investigate wave propagation in the duct. The theoretical prediction results show good agreement with the Finite Element Method (FEM) simulation results. The present study provides a practical way in noise control application of ventilation ductwork system by utilizing the advantage of periodicity with the limitation of available completed installation length for HRs. PMID:28471383

  20. Clinical Application of Six Current Classification Systems for Iatrogenic Bile Duct Injuries after Cholecystectomy.

    PubMed

    Velidedeoglu, Mehmet; Arikan, Akif Enes; Uludag, Sezgin Server; Olgun, Deniz Cebi; Kilic, Fahrettin; Kapan, Metin

    2015-05-01

    Due to being a severe complication, iatrogenic bile duct injury is still a challenging issue for surgeons in gallbladder surgery. However, a commonly accepted classification describing the type of injury has not been available yet. This study aims to evaluate ability of six current classification systems to discriminate bile duct injury patterns. Twelve patients, who were referred to our clinic because of iatrogenic bile duct injury after laparoscopic cholecystectomy were reviewed retrospectively. We described type of injury for each patient according to current six different classifications. 9 patients underwent definitive biliary reconstruction. Bismuth, Strasberg-Bismuth, Stewart-Way and Neuhaus classifications do not consider vascular involvement, Siewert system does, but only for the tangential lesions without structural loss of duct and lesion with a structural defect of hepatic or common bile duct. Siewert, Neuhaus and Stewart-Way systems do not discriminate between lesions at or above bifurcation of the hepatic duct. The Hannover classification may resolve the missing aspects of other systems by describing additional vascular involvement and location of the lesion at or above bifurcation.

  1. Antisense oligodeoxynucleotide to the cystic fibrosis gene inhibits anion transport in normal cultured sweat duct cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorscher, E.J.; Kirk, K.L.; Weaver, M.L.

    The authors have tested the hypothesis that the cystic fibrosis (CF) gene product, called the CF transmembrane conductance regulator (CFTR), mediates anion transport in normal human sweat duct cells. Sweat duct cells in primary culture were treated with oligodeoxynucleotides that were antisense to the CFTR gene transcript in order to block the expression of the wild-type CFTR. Anion transport in CFTR transcript antisense-treated cells was then assessed with a halide-specific dye, 6-methoxy-N-(3-sulfopropryl)quinolinium, and fluorescent digital imaging microscopy to monitor halide influx and efflux from single sweat duct cells. Antisense oligodeoxynucleotide treatment for 24 hr virtually abolished Cl{sup {minus}} transport inmore » sweat duct cells compared with untreated cells or control cells treated with sense oligodeoxynucleotides. Br{sup {minus}} uptake into sweat duct cells was also blocked after a 24-hr CFTR transcript antisense treatments, but not after treatments for only 4 hr. Lower concentrations of antisense oligodeoxynucleotides were less effective at inhibiting Cl{sup {minus}} transport. These results indicate that oligodeoxynucleotides that are antisense to CFTR transcript inhibit sweat duct Cl{sup {minus}} permeability in both a time-dependent and dose-dependent manner. This approach provides evidence that inhibition of the expression of the wild-type CFTR gene in a normal, untransfected epithelial cell results in an inhibition of Cl{sup {minus}} permeability.« less

  2. NIR DLP hyperspectral imaging system for medical applications

    NASA Astrophysics Data System (ADS)

    Wehner, Eleanor; Thapa, Abhas; Livingston, Edward; Zuzak, Karel

    2011-03-01

    DLP® hyperspectral reflectance imaging in the visible range has been previously shown to quantify hemoglobin oxygenation in subsurface tissues, 1 mm to 2 mm deep. Extending the spectral range into the near infrared reflects biochemical information from deeper subsurface tissues. Unlike any other illumination method, the digital micro-mirror device, DMD, chip is programmable, allowing the user to actively illuminate with precisely predetermined spectra of illumination with a minimum bandpass of approximately 10 nm. It is possible to construct active spectral-based illumination that includes but is not limited to containing sharp cutoffs to act as filters or forming complex spectra, varying the intensity of light at discrete wavelengths. We have characterized and tested a pure NIR, 760 nm to 1600 nm, DLP hyperspectral reflectance imaging system. In its simplest application, the NIR system can be used to quantify the percentage of water in a subject, enabling edema visualization. It can also be used to map vein structure in a patient in real time. During gall bladder surgery, this system could be invaluable in imaging bile through fatty tissue, aiding surgeons in locating the common bile duct in real time without injecting any contrast agents.

  3. Anatomical and metabolic assessment of prostate using a 3-Tesla MR scanner with a custom-made external transceive coil: healthy volunteer study.

    PubMed

    Kaji, Yasushi; Kuroda, Kagayaki; Maeda, Takaki; Kitamura, Yuri; Fujiwara, Toshitaka; Matsuoka, Yuichiro; Tamura, Mitsuru; Takei, Naoyuki; Matsuda, Tsuyoshi; Sugimura, Kazuro

    2007-03-01

    To examine the possibility of using a 3 Tesla (T) magnetic resonance (MR) scanner with a custom-made external coil to obtain ductal details of the prostate, high-quality spectra, and metabolite mapping corresponding to prostate zonal anatomy in healthy volunteers. MRI and two-dimensional (2D) chemical shift imaging (CSI) were performed in 16 healthy volunteers using a 3T scanner with a custom-made external transmit-receive (transceive) coil. Visualization of the prostatic duct-like structure was analyzed on T2-weighted (T2W) images. The resolution of the metabolite peaks and the distribution of metabolites in CSI were also assessed. In the axial plane, 3-mm-thick images were better than 4-mm-thick images with the same voxel volume for assessing duct-like structures and prostatic urethra. Differentiation between inner and outer citrate (Cit) peaks was frequently observed (29 out of 30). The mean peak area ratio of choline (Cho) plus creatine (Cr) over Cit in the peripheral zone (PZ) was significantly lower than in the transition zone (TZ) (P = 0.014). 3T MR examinations of the prostate using an external coil allow information to be collected about the details of duct-like structures, the high-quality spectra of Cit, and the zone-specific distribution of metabolites.

  4. Laminar heat transfer in annular sector ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soliman, H.M.

    1987-02-01

    The continuing interest in compact heat exchangeers has created the need for friction factor and Nusselt number data for different passage shapes. It has long been recognized that circular tube results are generally not applicable to noncircular passages even when the hydraulic diameter is used as the characteristic dimension. Hence, design data should be generated for each passage individually, and a good source of such information is Shah and London. One duct geometry for which complete design information does not appear to be available in the open literature is that of annular sector ducts. Such configuration is encountered in multipassagemore » internally finned tubes and many other compact het exchanger applications. The fluid flow problem for this configuration has been solved by Sparrow et al., and more recently by Niida. However, to the beest of the author's knowledge, the heat transfer results are not available yet. The purpose of this note is to summarize the analysis and results of fluid flow and heat transfer in annular sector ducts.« less

  5. Single lens system for forward-viewing navigation and scanning side-viewing optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Tate, Tyler H.; McGregor, Davis; Barton, Jennifer K.

    2017-02-01

    The optical design for a dual modality endoscope based on piezo scanning fiber technology is presented including a novel technique to combine forward-viewing navigation and side viewing OCT. Potential applications include navigating body lumens such as the fallopian tube, biliary ducts and cardiovascular system. A custom cover plate provides a rotationally symmetric double reflection of the OCT beam to deviate and focus the OCT beam out the side of the endoscope for cross-sectional imaging of the tubal lumen. Considerations in the choice of the scanning fiber are explored and a new technique to increase the divergence angle of the scanning fiber to improve system performance is presented. Resolution and the necessary scanning density requirements to achieve Nyquist sampling of the full image are considered. The novel optical design lays the groundwork for a new approach integrating side-viewing OCT into multimodality endoscopes for small lumen imaging. KEYWORDS:

  6. Strengthening of bridges by post-tensioning using monostrands in substituted cable ducts

    NASA Astrophysics Data System (ADS)

    Klusáček, Ladislav; Svoboda, Adam

    2017-09-01

    Post-tensioning is suitable, reliable and durable method of strengthening existing engineering structures, especially bridges. The high efficiency of post-tensioning can be seen in many applications throughout the world. In this paper the method is extended by a structural system of substituted cable ducts, which allows for significantly widening application of prestressing so it’s convenient mostly for application on beam bridges or slab bridges (built in years 1920 - 1960). The method of substituted cable ducts is based on theoretical knowledge and technical procedures, which were made possible through the development in prestressing systems, particularly the development of prestressing tendons (monostrands) and encased anchorages, as well as progress in drilling technology. This technique is highly recommended due to minimization of interventions into the constructions, unseen method of cable arrangement and hence the absence of impact on appearance, which is appreciated not only in case of valuable historical structures but also in general. It is possible to summarise that posttensioning by monostrands in substituted cable ducts is a highly effective method of strengthening existing bridges in order to increase their load capacities in terms of current traffic load and to extend their service life.

  7. A statistical theory for sound radiation and reflection from a duct

    NASA Technical Reports Server (NTRS)

    Cho, Y. C.

    1979-01-01

    A new analytical method is introduced for the study of the sound radiation and reflection from the open end of a duct. The sound is thought of as an aggregation of the quasiparticles-phonons. The motion of the latter is described in terms of the statistical distribution, which is derived from the classical wave theory. The results are in good agreement with the solutions obtained using the Wiener-Hopf technique when the latter is applicable, but the new method is simple and provides straightforward physical interpretation of the problem. Furthermore, it is applicable to a problem involving a duct in which modes are difficult to determine or cannot be defined at all, whereas the Wiener-Hopf technique is not.

  8. Photocopy of photograph (digital image located in LBNL Photo Lab ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (digital image located in LBNL Photo Lab Collection, XBD200503-00117-005). March 2005. PASSAGEWAY UNDER SOUTHEAST QUADRANT, AIR DUCT OPENINGS, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA

  9. A cost analysis of operative repair of major laparoscopic bile duct injuries.

    PubMed

    Hofmeyr, S; Krige, J E J; Bornman, P C; Beningfield, S J

    2015-06-01

    Major bile duct injuries occur infrequently after laparoscopic cholecystectomy, but may result in life-threatening complications. Few data exist on the financial implications of duct repair. This study calculated the costs of operative repair in a cohort of patients who underwent reconstruction of the bile duct after major ductal injury. To calculate the total in-hospital cost of surgical repair of patients referred with major bile duct injuries. A prospective database was reviewed to identify all patients referred to the University of Cape Town Private Academic Hospital, South Africa, between 2002 and 2013 for assessment and repair of major laparoscopic bile duct injuries. The detailed clinical records and billing information were evaluated to determine all costs from admission to discharge. Total costs for each patient were adjusted for inflation between the year of repair and 2013. Results. Forty-four patients (33 women, 11 men; median age 48 years, range 30 - 78) underwent reconstruction of a major bile duct injury. First-time repairs were performed at a median of 24.5 days (range 1 - 3,662) after initial surgery. Median hospital stay was 15 days (range 6 - 86). Mean cost of repair was ZAR215,711 (range ZAR68,764 - 980,830). Major contributors to cost were theatre expenses (22%), admission to intensive care (21%), radiology (17%) and specialist fees (12%). Admission to a general ward (10%), consumables (7%), pharmacy (5%), endoscopy (3%) and laboratory costs (3%) made up the balance. The cost of repair of a major laparoscopic bile duct injury is substantial owing to prolonged hospitalisation, complex surgicalintervention and intensive imaging requirements.

  10. Pushing the boundaries in liver graft utilisation in transplantation: Case report of a donor with previous bile duct injury repair.

    PubMed

    Sultana, Asma; Powell, James J; Oniscu, Gabriel C

    2017-01-01

    Liver transplantation is a recognised treatment for extensive bile duct injuries with secondary biliary cirrhosis or recurring sepsis. However, there have been no reports of successful liver transplantation from a donor who sustained a previous bile duct injury. Here we discuss the case of a liver transplant from a 51-year-old brain dead donor who had suffered a Strasberg E1 bile duct injury and had undergone a Roux-en-Y hepaticojejunostomy 24 years prior to donation. The liver was successfully recovered and transplanted into a 56-year-old male recipient with end stage liver disease consequent to alpha 1 antitrypsin deficiency. The graft continues to function well 36 months post-transplant, with normal liver function tests and imaging revealing a patent hepaticojejunostomy. The potential associated vascular injuries should be identified during bench preparation whilst the management of biliary reconstruction at the time of transplant should follow the principles of biliary reconstruction in cases with biliary injuries, extending the hilar opening into the left duct. This case highlights the successful utilisation of a post bile duct injury repair liver, employing an experienced procurement team and careful bench assessment and reconstruction. Copyright © 2017. Published by Elsevier Ltd.

  11. Finite element based stability-constrained weight minimization of sandwich composite ducts for airship applications

    NASA Astrophysics Data System (ADS)

    Khode, Urmi B.

    High Altitude Long Endurance (HALE) airships are platform of interest due to their persistent observation and persistent communication capabilities. A novel HALE airship design configuration incorporates a composite sandwich propulsive hull duct between the front and the back of the hull for significant drag reduction via blown wake effects. The sandwich composite shell duct is subjected to hull pressure on its outer walls and flow suction on its inner walls which result in in-plane wall compressive stress, which may cause duct buckling. An approach based upon finite element stability analysis combined with a ply layup and foam thickness determination weight minimization search algorithm is utilized. Its goal is to achieve an optimized solution for the configuration of the sandwich composite as a solution to a constrained minimum weight design problem, for which the shell duct remains stable with a prescribed margin of safety under prescribed loading. The stability analysis methodology is first verified by comparing published analytical results for a number of simple cylindrical shell configurations with FEM counterpart solutions obtained using the commercially available code ABAQUS. Results show that the approach is effective in identifying minimum weight composite duct configurations for a number of representative combinations of duct geometry, composite material and foam properties, and propulsive duct applied pressure loading.

  12. Balanced MR cholangiopancreatography with motion-sensitized driven-equilibrium (MSDE) preparation: Feasibility and optimization of imaging parameters.

    PubMed

    Nakayama, Tomohiro; Nishie, Akihiro; Yoshiura, Takashi; Asayama, Yoshiki; Ishigami, Kousei; Kakihara, Daisuke; Obara, Makoto; Honda, Hiroshi

    2015-12-01

    To show the feasibility of motion-sensitized driven-equilibrium-balanced magnetic resonance cholangiopancreatography and to determine the optimal velocity encoding (VENC) value. Sixteen healthy volunteers underwent MRI study using a 1.5-T clinical unit and a 32-channel body array coil. For each volunteer, images were obtained using the following seven respiratory-triggered sequences: (1) balanced magnetic resonance cholangiopancreatography without motion-sensitized driven-equilibrium, and (2)-(7) balanced magnetic resonance cholangiopancreatography with motion-sensitized driven-equilibrium, with VENC=1, 3, 5, 7, 9 and ∞cm/s for the x-, y-, and z-directions, respectively. Quantitative evaluation was obtained by measuring the maximum signal intensity of the common hepatic duct, portal vein, liver tissue including visible peripheral vessels, and liver tissue excluding visible peripheral vessels that were evaluated. We compared the contrast ratios of portal vein/common hepatic duct, liver tissue including visible peripheral vessels/common hepatic duct and liver tissue excluding visible peripheral vessels/common hepatic duct among the five finite sequences (VENC=1, 3, 5, 7, and 9cm/s). Statistical comparisons were performed using the t-test for paired data with the Bonferroni correction. Suppression of blood vessel signals was achieved with motion-sensitized driven-equilibrium sequences. We found the optimal VENC values to be either 3 or 5cm/s with the best suppression of relative vessel signals to bile ducts. At a lower VENC value (1cm/s), the bile duct signal was reduced, presumably due to minimal biliary flow. The feasibility of motion-sensitized driven-equilibrium-balanced magnetic resonance cholangiopancreatography was suggested. The optimal VENC value was considered to be either 3 or 5cm/s. The clinical usefulness of this new magnetic resonance cholangiopancreatography sequence needs to be verified by further studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Technical report: gadoxetate-disodium-enhanced 2D R2* mapping: a novel approach for assessing bile ducts in living donors.

    PubMed

    Fazeli Dehkordy, Soudabeh; Fowler, Kathryn J; Wolfson, Tanya; Igarashi, Saya; Lamas Constantino, Carolina P; Hooker, Jonathan C; Hong, Cheng W; Mamidipalli, Adrija; Gamst, Anthony C; Hemming, Alan; Sirlin, Claude B

    2017-10-31

    Gadoxetate-disodium (Gd-EOB-DTPA)-enhanced 3D T1- weighted (T1w) MR cholangiography (MRC) is an efficient method to evaluate biliary anatomy due to T1 shortening of excreted contrast in the bile. A method that exploits both T1 shortening and T2* effects may produce even greater bile duct conspicuity. The aim of our study is to determine feasibility and compare the diagnostic performance of two-dimensional (2D) T1w multi-echo (ME) spoiled gradient-recalled-echo (SPGR) derived R2* maps against T1w MRC for bile duct visualization in living liver donor candidates. Ten potential living liver donor candidates underwent pretransplant 3T MRI and were included in our study. Following injection of Gd-EOBDTPA and a 20-min delay, 3D T1w MRC and 2D T1w ME SPGR images were acquired. 2D R2* maps were generated inline by the scanner assuming exponential decay. The 3D T1w MRC and 2D R2* maps were retrospectively and independently reviewed in two separate sessions by three radiologists. Visualization of eight bile duct segments was scored using a 4-point ordinal scale. The scores were compared using mixed effects regression model. Imaging was tolerated by all donors and R2* maps were successfully generated in all cases. Visualization scores of 2D R2* maps were significantly higher than 3D T1w MRC for right anterior (p = 0.003) and posterior (p = 0.0001), segment 2 (p < 0.0001), segment 3 (p = 0.0001), and segment 4 (p < 0.0001) ducts. Gd-EOB-DTPA-enhanced 2D R2* mapping is a feasible method for evaluating the bile ducts in living donors and may be a valuable addition to the living liver donor MR protocol for delineating intrahepatic biliary anatomy.

  14. Indocyanine-green-loaded microballoons for biliary imaging in cholecystectomy

    NASA Astrophysics Data System (ADS)

    Mitra, Kinshuk; Melvin, James; Chang, Shufang; Park, Kyoungjin; Yilmaz, Alper; Melvin, Scott; Xu, Ronald X.

    2012-11-01

    We encapsulate indocyanine green (ICG) in poly[(D,L-lactide-co-glycolide)-co-PEG] diblock (PLGA-PEG) microballoons for real-time fluorescence and hyperspectral imaging of biliary anatomy. ICG-loaded microballoons show superior fluorescence characteristics and slower degradation in comparison with pure ICG. The use of ICG-loaded microballoons in biliary imaging is demonstrated in both biliary-simulating phantoms and an ex vivo tissue model. The biliary-simulating phantoms are prepared by embedding ICG-loaded microballoons in agar gel and imaged by a fluorescence imaging module in a Da Vinci surgical robot. The ex vivo model consists of liver, gallbladder, common bile duct, and part of the duodenum freshly dissected from a domestic swine. After ICG-loaded microballoons are injected into the gallbladder, the biliary structure is imaged by both hyperspectral and fluorescence imaging modalities. Advanced spectral analysis and image processing algorithms are developed to classify the tissue types and identify the biliary anatomy. While fluorescence imaging provides dynamic information of movement and flow in the surgical region of interest, data from hyperspectral imaging allow for rapid identification of the bile duct and safe exclusion of any contaminant fluorescence from tissue not part of the biliary anatomy. Our experiments demonstrate the technical feasibility of using ICG-loaded microballoons for biliary imaging in cholecystectomy.

  15. Photocopy of photograph (digital image located in LBNL Photo Lab ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of photograph (digital image located in LBNL Photo Lab Collection, XBD200503-00117-009). March 2005. OPENINGS OF AIR DUCTS INTO PASSAGEWAY UNDER SOUTHEAST QUADRANT, BEVATRON - University of California Radiation Laboratory, Bevatron, 1 Cyclotron Road, Berkeley, Alameda County, CA

  16. Acute Cholangitis After Bilioenteric Anastomosis for Bile Duct Injuries.

    PubMed

    Ortiz-Brizuela, Edgar; Sifuentes-Osornio, José; Manzur-Sandoval, Daniel; Terán-Ellis, Santiago Mier Y; Ponce-de-León, Sergio; Torres-González, Pedro; Mercado, Miguel Ángel

    2017-10-01

    The study aims to describe the clinical features, microbiology, and associated factors of acute cholangitis (AC) after bilioenteric anastomosis (BEA) for biliary duct injury (BDI). Additionally, we assessed the performance of the Tokyo Guidelines 2013 (TG13) recommendations in these patients. We conducted a case-control study of 524 adults with a history of BEA for BDI from January 2000 to January 2014. A propensity score adjustment was performed for the analysis of the independent role of the main factors identified during the univariate logistic regression procedure. We identified 117 episodes of AC in 70 patients; 51.3% were definitive AC according to the TG13 diagnostic criteria, and 39.3% did not fulfill the imaging criteria of AC. A history of post-operative biliary complications (OR 2.55, 95% CI 1.38-4.70) and the bile duct confluence preservation (OR 0.46, 95% CI 0.24-0.87) were associated with AC. Eighty-nine percent of the microorganisms were Enterobacteriaceae; of them, 28% were extended spectrum β-lactamase (ESBL) producers. AC is a common complication after BEA and must be suspected even in the absence of imaging findings, particulary in patients with a history of post-operative biliary complications, and/or without bile duct confluence preserved. An empirical treatment for ESBL-producing Enterobacteriaceae may be appropriate in patients living in countries with a high rate of bacterial drug resistance.

  17. Argon/UF6 plasma exhaust gas reconstitution experiments using preheated fluorine and on-line diagnostics. [fissioning uranium plasma core reactor design

    NASA Technical Reports Server (NTRS)

    Roman, W. C.

    1979-01-01

    The feasibility of employing a flowing, high-temperature, pure fluorine/UF6 regeneration system to efficiently convert a large fraction of the effluent plasma exhaust back to pure UF6 was demonstrated. The custom built T.O.F. mass spectrometer sampling system permitted on-line measurements of the UF6 concentration at different locations in the exhaust system. Negligible amounts ( 100 ppm) of UF6 were detected in the axial bypass exhaust duct and the exhaust ducts downstream of the cryogenic trap system used to collect the UF6, thus verifying the overall system efficiency over a range of operating conditions. Use of a porous Monel duct as part of the exhaust duct system, including provision for injection of pure fluorine, provided a viable technique to eliminate uranium compound residue on the inside surface of the exhaust ducts. Typical uranium compound mass deposition per unit area of duct was 2 micron g/sq cm. This porous duct technique is directly applicable to future uranium compound transfer exhaust systems. Throughout these experiments, additional basic data on the corrosion aspects of hot, pressurized UF6/fluorine were also accumulated.

  18. Iodine-131 Therapy and Nasolacrimal Duct Obstructions: What We Know and What We Need to Know.

    PubMed

    Ali, Mohammad Javed

    2016-01-01

    The aims of the current review are to summarize the etiopathogenesis, symptomatology, management, complications, and outcomes of iodine-131-induced nasolacrimal duct obstructions, to propose a screening protocol and elucidate the potential avenues of future research. The authors performed an electronic database (PubMed, MEDLINE, EMBASE, and Cochrane Library) search of all articles published in English on nasolacrimal duct obstructions following radioiodine therapy. These articles were reviewed along with their relevant cross references. Data reviewed included demographics, presentations, investigations, management, complications, and outcomes. In addition, based on relevant unanswered questions and current lacunae in literature, potential avenues for further research have been elucidated. The frequency of nasolacrimal duct obstruction is reported to range from 2.2% to 18% following I-131 therapy. They are mostly bilateral and noted in patients who receive more than 150 mCi radioiodine. Exact etiopathogenesis is unknown but radiotoxicity to lacrimal sac and nasolacrimal duct is believed to be mediated through a sodium-iodine symporter protein. Although uncommon, it is important to increase awareness among treating physicians and patients receiving radioiodine therapy about the potential side effect of nasolacrimal duct obstruction. Imaging modalities are useful adjuncts in the diagnosis. Dacryocystorhinostomy is the most common modality of management with good outcomes. Nasolacrimal duct obstruction following radioiodine treatment is a distinct clinical entity. Increased awareness would facilitate timely diagnosis, management, and an enhanced quality of life for the patients.

  19. Effects of partial portal vein arterialization on the hilar bile duct in a rat model.

    PubMed

    Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng

    2011-10-01

    Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (P<0.01). No apoptotic hilar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (P<0.01). No statistically significant differences in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and albumin were found in the 3 groups. The gamma-glutamyltransferase value was higher in group B than in groups A and C (P<0.01). The hepatic tissues of groups A and C showed no significant abnormality. Chronic inflammatory changes in the hilar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.

  20. Computational aero-acoustics for fan duct propagation and radiation. Current status and application to turbofan liner optimisation

    NASA Astrophysics Data System (ADS)

    Astley, R. J.; Sugimoto, R.; Mustafi, P.

    2011-08-01

    Novel techniques are presented to reduce noise from turbofan aircraft engines by optimising the acoustic treatment in engine ducts. The application of Computational Aero-Acoustics (CAA) to predict acoustic propagation and absorption in turbofan ducts is reviewed and a critical assessment of performance indicates that validated and accurate techniques are now available for realistic engine predictions. A procedure for integrating CAA methods with state of the art optimisation techniques is proposed in the remainder of the article. This is achieved by embedding advanced computational methods for noise prediction within automated and semi-automated optimisation schemes. Two different strategies are described and applied to realistic nacelle geometries and fan sources to demonstrate the feasibility of this approach for industry scale problems.

  1. Paraduodenal Pancreatitis: Imaging and Pathologic Correlation of 47 Cases Elucidates Distinct Subtypes and the Factors Involved in its Etiopathogenesis.

    PubMed

    Muraki, Takashi; Kim, Grace E; Reid, Michelle D; Mittal, Pardeep; Bedolla, Gabriela; Memis, Bahar; Pehlivanoglu, Burcin; Freedman, Alexa; Erbarut Seven, Ipek; Choi, Hyejeong; Kooby, David; Maithel, Shishir K; Sarmiento, Juan M; Krasinskas, Alyssa; Adsay, Volkan

    2017-10-01

    Clinicopathologic characteristics of paraduodenal (groove) pancreatitis (PDP) remain to be fully unraveled. In this study, 47 PDPs with preoperative enhanced images available were subjected to detailed comparative analysis in conjunction with pathologic findings. PDP were predominantly in males (3:1) with a mean age of 50 years, and 60% had a preoperative diagnosis of cancer. Mean lesional size was 3.1 cm. Three distinct subtypes were identified by imaging. Solid-tumoral (type-1) with groove-predominant (type-1A, 36%) forming a distinct solid band between the duodenum and pancreas often with histologic microabscesses (69% vs. 33% in others), and pancreas-involving (type-1B, 19%) forming a pseudotumoral mass spanning into the head-groove area, always diagnosed preoperatively as "cancer," but often lacked parenchymal atrophy of the body (44% vs. 92%). Cyst-forming (type-2) had groove-predominant (type-2A, 15%), often accompanied by Brunner gland hyperplasia, and pancreas-predominant (type-2B, 15%) were in younger (mean: 44 y) females (57% vs. 18%) and had less alcohol/tobacco abuse (50/33% vs. 81/69%). Ill-defined (type-3; 15%) often had main pancreatic duct dilatation (mean: 5.6 vs. 2.8 mm). The capricious presentations of PDP could be attributed to variable effects of different mechanistic and precipitative etiopathogenetic factors such as disturbed accessory duct outflow (dilated Santorini duct, 87%), aggravated by alcohol (77%) with superimposed stasis in the main ampulla (previous cholecystectomy, 47%; choledocholithiasis, 9%), strictured Wirsung duct (68%), and some likely exacerbated by ischemia (hypertension [59%], tobacco abuse [64%], arteriosclerosis in the tissue [23%]). In conclusion, our study identified 3 distinct types of PDP and each may reflect different pathogenetic contributing factors.

  2. Toward surface quantification of liver fibrosis progression

    NASA Astrophysics Data System (ADS)

    He, Yuting; Kang, Chiang Huen; Xu, Shuoyu; Tuo, Xiaoye; Trasti, Scott; Tai, Dean C. S.; Raja, Anju Mythreyi; Peng, Qiwen; So, Peter T. C.; Rajapakse, Jagath C.; Welsch, Roy; Yu, Hanry

    2010-09-01

    Monitoring liver fibrosis progression by liver biopsy is important for certain treatment decisions, but repeated biopsy is invasive. We envision redefinition or elimination of liver biopsy with surface scanning of the liver with minimally invasive optical methods. This would be possible only if the information contained on or near liver surfaces accurately reflects the liver fibrosis progression in the liver interior. In our study, we acquired the second-harmonic generation and two-photon excitation fluorescence microscopy images of liver tissues from bile duct-ligated rat model of liver fibrosis. We extracted morphology-based features, such as total collagen, collagen in bile duct areas, bile duct proliferation, and areas occupied by remnant hepatocytes, and defined the capsule and subcapsular regions on the liver surface based on image analysis of features. We discovered a strong correlation between the liver fibrosis progression on the anterior surface and interior in both liver lobes, where biopsy is typically obtained. The posterior surface exhibits less correlation with the rest of the liver. Therefore, scanning the anterior liver surface would obtain similar information to that obtained from biopsy for monitoring liver fibrosis progression.

  3. Diagnostic value of Gd-EOB-DTPA-enhanced MR cholangiography in non-invasive detection of postoperative bile leakage.

    PubMed

    Kul, Melahat; Erden, Ayşe; Düşünceli Atman, Ebru

    2017-04-01

    To assess the diagnostic value of dynamic T 1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. A total of 28 patients with suspected biliary leakage who underwent routine T 2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p < 0.001). 19 of 28 patients had bile leak findings in T1w Gd-EOB-DTPA-enhanced MRC [HBP group: N = 7 (36.8%), DP group: N = 12 (63.2%)]. There was no statistically significant difference in terms of laboratory test results and the presence of bile duct dilatation between HBP and DP group (p > 0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.

  4. A method to determine the acoustical properties of locally and nonlocally reacting duct liners in grazing flow

    NASA Technical Reports Server (NTRS)

    Succi, G.

    1982-01-01

    The acoustical properties of locally and nonlocally reacting acoustical liners in grazing flow are described. The effect of mean flow and shear flow are considered as well as the application to rigid and limp bulk reacting materials. The axial wavenumber of the least attenuated mode in a flow duct is measured. The acoustical properties of duct liners is then deduced from the measured axial wavenumber and known flow profile and boundary conditions. This method is a natural extension of impedance-like measurements.

  5. Application of 'steady' state finite element and transient finite difference theory to sound propagation in a variable duct - A comparison with experiment

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.; Eversman, W.; Astley, R. J.; White, J. W.

    1981-01-01

    Experimental data are presented for sound propagation in a simulated infinite hard wall duct with a large change in duct cross sectional area. The data are conveniently tabulated for further use. The 'steady' state finite element theory of Astley and Eversman (1981) and the transient finite difference theory of White (1981) are in good agreement with the data for both the axial and transverse pressure profiles and the axial phase angle. Therefore, numerical finite difference and finite element theories appear to be ideally suited for handling duct propagation problems which encounter large axial gradients in acoustic parameters. The measured energy reflection coefficient agrees with the values from the Astley-Eversman modal coupling model.

  6. Duct modes damping through an adjustable electroacoustic liner under grazing incidence

    NASA Astrophysics Data System (ADS)

    Boulandet, R.; Lissek, H.; Karkar, S.; Collet, M.; Matten, G.; Ouisse, M.; Versaevel, M.

    2018-07-01

    This paper deals with active sound attenuation in lined ducts with flow and its application to duct modes damping in aircraft engine nacelles. It presents an active lining concept based on an arrangement of electroacoustic absorbers flush mounted in the duct wall. Such feedback-controlled loudspeaker membranes are used to achieve locally reacting impedances with adjustable resistance and reactance. A broadband impedance model is formulated from the loudspeaker parameters and a design procedure is proposed to achieve specified acoustic resistances and reactances. The performance is studied for multimodal excitation by simulation using the finite element method and the results are compared to measurements made in a flow duct facility. This electroacoustic liner has an attenuation potential comparable to that of a conventional passive liner, but also offers greater flexibility to achieve the target acoustic impedance in the low frequencies. In addition, it is adaptive in real time to track variable engine speeds. It is shown with the liner prototype that the duct modes can be attenuated over a bandwidth of two octaves around the resonance frequency of the loudspeakers.

  7. Pseudotumor of the distal common bile duct at endoscopic retrograde cholangiopancreatography

    PubMed Central

    Tan, Justin H.; Coakley, Fergus V; Wang, Zhen J.; Poder, Liina; Webb, Emily; Yeh, Benjamin M.

    2010-01-01

    Background Prior studies have described a pseudocalculus appearance in the distal common bile duct as a normal variant at cholangiography. The objective of this study is to describe the occurrence of pseudotumor in the distal common bile duct at endoscopic retrograde cholangiopancreatography (ERCP). Methods Nine patients who underwent ERCP between May 2004 and July 2008 were identified as having a transient eccentric mural-based filling defect in the distal common bile duct. A single reader systematically reviewed all studies and recorded the imaging findings. Results The mean diameter of the filling defect was 9 mm (range, 5 to 11). Eight patients had resolution of the filling defect during the same ERCP or on a subsequent ERCP, and in 2 of these patients the inferior border of the filling defect was not well visualized. The other patient underwent surgical resection of a presumed tumor with no evidence of malignancy on surgical pathology. Conclusion An eccentric mural-based filling defect in the distal common bile duct can be artifactual in nature and may reflect transient contraction of the sphincter of Oddi. Recognition of this pseudotumor may help avoid unnecessary surgery. PMID:21724120

  8. Tensile and Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials

    NASA Technical Reports Server (NTRS)

    Gabb, Timothy P.; Gayda, John

    2006-01-01

    This paper represents a status report documenting the work on creep of superalloys performed under Project Prometheus. Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, are being screened to compare their respective capabilities for impeller applications. Several wrought superalloys including Hastelloy X, (Haynes International, Inc., Kokomo, IN), Inconel 617, Inconel 740, Nimonic 263, and Incoloy MA956 (Special Metals Corporation, Huntington, WV) are also being screened to compare their capabilities for duct applications. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Conventional tensile and creep tests were performed at temperatures up to 1200 K on specimens extracted from the materials. Initial microstructure evaluations were also undertaken.

  9. Truss-Integrated Thermoformed Ductwork Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Winter; Dianne Griffiths; Ravi Gorthala

    2007-08-30

    This report summarizes a multi-year research effort to develop a leak-free duct system that can be readily installed within the thermal envelope. There are numerous efforts underway to improve duct system efficiency. Most of these involve modifications to current technology such as air sealing techniques like mastic and aeroseal, snap together duct connections, and greater levels of insulation. This project sought to make a more significant stride forward by introducing a duct system of a material that can be more readily sealed and can exhibit lower friction losses. The research focused on the use of smooth internal surface, low frictionmore » plastic ducts that could be easily installed with very low air leakage. The initial system concept that was proposed and researched in Phase I focused on the use of thermoformed plastic ducts installed in a recessed roof truss underneath the attic insulation. A bench top thermoformed system was developed and tested during Phase I of the project. In Phase II, a first generation duct system utilizing a resin impregnated fiberglass duct product was designed and specified. The system was installed and tested in an Atlanta area home. Following this installation research and correspondence with code officials was undertaken to alleviate the continued concern over the code acceptance of plastic ducts in above ground applications. A Committee Interpretation response was received from the International Code Council (ICC) stating that plastic ducts were allowed, but must be manufactured from materials complying with Class 0 or Class 1 rating. With assurance of code acceptance, a plastic duct system using rotomolded high density polyethylene ducts that had passed the material test requirements by impregnating the material with a fire retardant during the molding process was installed in the basement of a new ranch-style home in Madison, WI. A series of measurements to evaluate the performance benefits relative to a similar control house with a standard sheet metal installation were made.« less

  10. [Electrohydraulic intracorporeal lithotripsy of salivary calculi. In vitro and animal experiment studies].

    PubMed

    Iro, H; Zenk, J; Hosemann, W G; Benzel, W

    1993-08-01

    Extracorporeal lithotripsy is now used routinely for the treatment of salivary duct stones. The question arose whether electrohydraulic intracorporeal lithotripsy, which is applied in urology and gastroenterology, might also be useful in the treatment of this disease. Before its possible clinical application the influence of electrohydraulic intracorporeal shock waves on salivary stones in vitro and any influence on the tissue in the head and neck region (in vivo) had to be investigated. In vitro experiments. Fifty-eight salivary stones and 11 extirpated human submandibular glands were treated by three different electrohydraulic devices. Animal experiments. Electrohydraulic shock waves were applied to the dilated Stensen's duct and other tissues (muscle, parotid gland, facial nerve) of six rabbits. Of 58 salivary stones, 53 (91%) were fragmented, 39 (67%) with a remaining size of less than 1.5 mm and 14 (24%) more than 1.5 mm. In 5 cases (9%) no effects were seen at all. Fragmentation occurred independent of the mineralogical components of the stone and independent of the different lithotriptors used. The smaller the probe diameter and the larger the stone, the more shock waves were needed to achieve fragmentation. With the smaller probes the stones could not be fragmented completely. In human submandibular glands, extensive tissue lesions could be evidenced macroscopically and histologically after application of electrohydraulic shock waves in vitro. Application of electrohydraulic shock waves to the dilated parotid gland duct of rabbits led to perforations of the duct after 1-5 single pulses. Lesions of nerves and blood vessels could also be observed within the duct environment. This occurred with all of the different electrohydraulic devices, probe diameters and intensities used. In our opinion the damage produced is probably the result of both the direct effect of the plasma as well as the resultant stress wave. In view of the severe damage caused to different tissues, use of the described method for the treatment of stones in the narrow human salivary ducts should be greatly restricted.

  11. Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    PubMed

    Fischer, Anja; Kraff, Oliver; Orzada, Stephan; Nensa, Felix; Schäfer, Lena C; Ladd, Mark E; Umutlu, Lale; Lauenstein, Thomas C

    2014-05-01

    The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2-weighted turbo-spin-echo sequence, T1-w volume-interpolated breath-hold examination (VIBE), and fast low-angle shot (FLASH) with inversion recovery (IR) were acquired in coronal orientation. For dynamic imaging, gadoxetic acid was administrated and data were collected for a period of 5 to 40 minutes after injection. The volunteers underwent subsequent T2-w respiratory-gated MRC at 3 T. For qualitative analysis, a 5-point scale was used. Contrast ratios (CRs) were calculated for quantitative assessment. Contrast-enhanced T1-w MRC at 7 T showed a homogeneous depiction of the intrahepatic and extrahepatic biliary tract with a maximum enhancement of 20 minutes after contrast. Volume-interpolated breath-hold examination and FLASH IR provided a good image quality for the intrahepatic (VIBE, 3.60; FLASH IR, 3.67) and extrahepatic bile ducts (VIBE, 3.50; FLASH IR, 3.72). The quantitative analysis revealed high CR values for FLASH IR (intrahepatic CR, 0.41; extrahepatic CR, 0.45) because of an effective suppression of hepatic tissue and vessels. The T2-w TSE at 7 T showed only a poor image quality without diagnostic potential (intrahepatic, 2.22; extrahepatic, 1.93). Seven-tesla VIBE and FLASH revealed superiority in the depiction of the intrahepatic bile ducts, whereas 3-T MRC was superior in the delineation of the extrahepatic biliary tract. Our results demonstrate the feasibility of contrast-enhanced imaging of the biliary ducts at 7 T.

  12. Verification of the FBR fuel bundle-duct interaction analysis code BAMBOO by the out-of-pile bundle compression test with large diameter pins

    NASA Astrophysics Data System (ADS)

    Uwaba, Tomoyuki; Ito, Masahiro; Nemoto, Junichi; Ichikawa, Shoichi; Katsuyama, Kozo

    2014-09-01

    The BAMBOO computer code was verified by results for the out-of-pile bundle compression test with large diameter pin bundle deformation under the bundle-duct interaction (BDI) condition. The pin diameters of the examined test bundles were 8.5 mm and 10.4 mm, which are targeted as preliminary fuel pin diameters for the upgraded core of the prototype fast breeder reactor (FBR) and for demonstration and commercial FBRs studied in the FaCT project. In the bundle compression test, bundle cross-sectional views were obtained from X-ray computer tomography (CT) images and local parameters of bundle deformation such as pin-to-duct and pin-to-pin clearances were measured by CT image analyses. In the verification, calculation results of bundle deformation obtained by the BAMBOO code analyses were compared with the experimental results from the CT image analyses. The comparison showed that the BAMBOO code reasonably predicts deformation of large diameter pin bundles under the BDI condition by assuming that pin bowing and cladding oval distortion are the major deformation mechanisms, the same as in the case of small diameter pin bundles. In addition, the BAMBOO analysis results confirmed that cladding oval distortion effectively suppresses BDI in large diameter pin bundles as well as in small diameter pin bundles.

  13. [Bile duct reconstruction using 3-dimensional collagen tubes].

    PubMed

    Pérez Alonso, Alejandro José; del Olmo Rivas, Carlos; Machado Romero, Ignacio; Pérez Cabrera, Beatriz; Cañizares Garcia, Francisco Javier; Torne Poyatos, Pablo

    2013-11-01

    In recent years, with widespread laparoscopic cholecystectomy and liver transplantation, complications involving the biliary system are increasing. All current techniques have a high risk of recurrence or high-morbidity. A 3-dimensional collagen bile duct modified with agarose hydrogel was developed to substitute the affected extrahepatic bile duct. It was used in 40 guinea pigs and the histology and physiology was studied at 4 weeks, 3 and 6 months after transplantation. The graft shows to have a high potential in applications to treat hepatobiliary diseases which require surgery. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  14. Intraluminal measurement of papillary duct urine pH, in vivo: a pilot study in the swine kidney.

    PubMed

    Handa, Rajash K; Lingeman, James E; Bledsoe, Sharon B; Evan, Andrew P; Connors, Bret A; Johnson, Cynthia D

    2016-06-01

    We describe the in vivo use of an optic-chemo microsensor to measure intraluminal papillary duct urine pH in a large mammal. Fiber-optic pH microsensors have a tip diameter of 140-µm that allows insertion into papillary Bellini ducts to measure tubule urine proton concentration. Anesthetized adult pigs underwent percutaneous nephrolithotomy to access the lower pole of the urinary collecting system. A flexible nephroscope was advanced towards an upper pole papilla with the fiber-optic microsensor contained within the working channel. The microsensor was then carefully inserted into Bellini ducts to measure tubule urine pH in real time. We successfully recorded tubule urine pH values in five papillary ducts from three pigs (1 farm pig and 2 metabolic syndrome Ossabaw pigs). Our results demonstrate that optical microsensor technology can be used to measure intraluminal urine pH in real time in a living large mammal. This opens the possibility for application of this optical pH sensing technology in nephrolithiasis.

  15. Fast subsurface fingerprint imaging with full-field optical coherence tomography system equipped with a silicon camera

    NASA Astrophysics Data System (ADS)

    Auksorius, Egidijus; Boccara, A. Claude

    2017-09-01

    Images recorded below the surface of a finger can have more details and be of higher quality than the conventional surface fingerprint images. This is particularly true when the quality of the surface fingerprints is compromised by, for example, moisture or surface damage. However, there is an unmet need for an inexpensive fingerprint sensor that is able to acquire high-quality images deep below the surface in short time. To this end, we report on a cost-effective full-field optical coherent tomography system comprised of a silicon camera and a powerful near-infrared LED light source. The system, for example, is able to record 1.7 cm×1.7 cm en face images in 0.12 s with the spatial sampling rate of 2116 dots per inch and the sensitivity of 93 dB. We show that the system can be used to image internal fingerprints and sweat ducts with good contrast. Finally, to demonstrate its biometric performance, we acquired subsurface fingerprint images from 240 individual fingers and estimated the equal-error-rate to be ˜0.8%. The developed instrument could also be used in other en face deep-tissue imaging applications because of its high sensitivity, such as in vivo skin imaging.

  16. Side-branch resonators modelling with Green's function methods

    NASA Astrophysics Data System (ADS)

    Perrey-Debain, E.; Maréchal, R.; Ville, J. M.

    2014-09-01

    This paper deals with strategies for computing efficiently the propagation of sound waves in ducts containing passive components. In many cases of practical interest, these components are acoustic cavities which are connected to the duct. Though standard Finite Element software could be used for the numerical prediction of sound transmission through such a system, the method is known to be extremely demanding, both in terms of data preparation and computation, especially in the mid-frequency range. To alleviate this, a numerical technique that exploits the benefit of the FEM and the BEM approach has been devised. First, a set of eigenmodes is computed in the cavity to produce a numerical impedance matrix connecting the pressure and the acoustic velocity on the duct wall interface. Then an integral representation for the acoustic pressure in the main duct is used. By choosing an appropriate Green's function for the duct, the integration procedure is limited to the duct-cavity interface only. This allows an accurate computation of the scattering matrix of such an acoustic system with a numerical complexity that grows very mildly with the frequency. Typical applications involving Helmholtz and Herschel-Quincke resonators are presented.

  17. Credit BG. View looking northeast down from the tower onto ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking northeast down from the tower onto the two horizontal test stations at Test Stand "D." Station Dy is at the far left (Dy vacuum cell out of view), with in-line exhaust gas cooling sections and steam-driven "air ejector" (or evacuator) discharging engine exhausts to the east. The Dd cell is visible at the lower left, and the Dd exhaust train has the same functions as at Dy. The spherical tank is an electrically heated "accumulator" which supplies steam to the ejectors at Dv, Dd, and Dy stations. Other large piping delivered cooling water to the horizontal train cooling sections. The horizontal duct at the "Y" branch in the Dd train connects the Dd ejector to the Dv and Cv vacuum duct system (a blank can be bolted into this duct to isolate the Dd system). The shed roof for the Dpond test station appears at bottom center of this image. The open steel frame to the lower left of the image supports a hoist and crane for installing or removing test engines from the Dd test cell - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  18. Particle image velocimetry investigation of a finite amplitude pressure wave

    NASA Astrophysics Data System (ADS)

    Thornhill, D.; Currie, T.; Fleck, R.; Chatfield, G.

    2006-03-01

    Particle image velocimetry is used to study the motion of gas within a duct subject to the passage of a finite amplitude pressure wave. The wave is representative of the pressure waves found in the exhaust systems of internal combustion engines. Gas particles are accelerated from stationary to 150 m/s and then back to stationary in 8 ms. It is demonstrated that gas particles at the head of the wave travel at the same velocity across the duct cross section at a given point in time. Towards the tail of the wave viscous effects are plainly evident causing the flow profile to tend towards parabolic. However, the instantaneous mean particle velocity across the section is shown to match well with the velocity calculated from a corresponding measured pressure history using 1D gas dynamic theory. The measured pressure history at a point in the duct was acquired using a high speed pressure transducer of the type typically used for engine research in intake and exhaust systems. It is demonstrated that these are unable to follow the rapid changes in pressure accurately and that they are prone to resonate under certain circumstances.

  19. Application of Gr/PMR-15 to commercial aircraft

    NASA Technical Reports Server (NTRS)

    Postlewaite, J.; Porter, K.; Mclaren, D.

    1985-01-01

    Following from early experience with polyimides on the SST program and Shuttle aft flap studies the Boeing Company is now working on collaborative programs with its principal nacelle suppliers to pursue the development of Gr/PMR-15 nacelle components. Two programs are currently in effect. The first program is directed specifically towards the flight test and service evaluation at the earliest possible date of a 747 nacelle core cowl structure. The second program seeks to firmly establish the producibility and cost of a 757 thrust reverser C duct in a production environment. The near term objectives of these programs include: (1) the comparison of estimated cost and weight of Gr/PMR-15 versus metal structure, (2) the engine test of representative composite structure, (3) the preliminary design and analysis of the C duct structure, and (4) the preparation of cost data and time schedules for the development and producibility program. In addition to powerplant structure, the propulsion ducting system has shown to be a strong candidate for Gr/PMR-15 application. Currently, the Boeing 747 Organization is evaluating the use of PMR-15 matrix composites to replace nearly 800 lbs of titanium ducting per airplane.

  20. Biliary Stenosis and Gastric Outlet Obstruction: Late Complications After Acute Pancreatitis With Pancreatic Duct Disruption.

    PubMed

    Sugimoto, Motokazu; Sonntag, David P; Flint, Greggory S; Boyce, Cody J; Kirkham, John C; Harris, Tyler J; Carr, Sean M; Nelson, Brent D; Bell, Don A; Barton, Joshua G; Traverso, L William

    2018-07-01

    Pancreatic duct disruption (PDD) after acute pancreatitis can cause pancreatic collections in the early phase and biliary stenosis (BS) or gastric outlet obstruction (GOO) in the late phase. We aimed to document those late complications after moderate or severe acute pancreatitis. Between September 2010 and August 2014, 141 patients showed pancreatic collections on computed tomography. Percutaneous drainage was primarily performed for patients with signs or symptoms of uncontrolled pancreatic juice leakage. Pancreatic duct disruption was defined as persistent amylase-rich drain fluid or a pancreatic duct cut-off on imaging. Clinical course of the patients who developed BS or GOO was investigated. Among the 141 patients with collections, 33 patients showed PDD in the pancreatic head/neck area. Among them, 9 patients (27%) developed BS 65 days after onset and required stenting for 150 days, and 5 patients (15%) developed GOO 92 days after onset and required gastric decompression and jejunal tube feeding for 147 days (days shown in median). All 33 patients recovered successfully without requiring surgical intervention. Anatomic proximity of the bile duct or duodenum to the site of PDD and severe inflammation seemed to contribute to the late onset of BS or GOO. Conservative management successfully reversed these complications.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melenhorst, Marleen C. A. M., E-mail: m.melenhorst@vumc.nl; Scheffer, Hester J., E-mail: hj.scheffer@vumc.nl; Vroomen, Laurien G. P. H., E-mail: la.vroomen@vumc.nl

    Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant tumors located near large vessels or bile ducts. The presence of metal objects in the ablation zone, such as Wallstents, is generally considered a contraindication for IRE, because tissue heating due to power conduction may lead to thermal complications. This report describes a 66-year-old female with a Bismuth–Corlette stage IV unresectable cholangiocarcinoma with a metallic Wallstent in the common bile duct, who was safely treated with percutaneous IRE with no signs for relapse 1 year after the procedure.

  2. Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials

    NASA Astrophysics Data System (ADS)

    Gabb, Timothy P.; Gayda, John; Garg, Anita

    2007-01-01

    Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy® X, Inconel® 617, Inconel® 740, Nimonic® 263, Incoloy® MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.

  3. Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials

    NASA Technical Reports Server (NTRS)

    Gabb, Timothy P.; Gayda, john; Garg, Anita

    2007-01-01

    Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy(Registered TradeMark) X, Inconel(Registered TradeMark) 617, Inconel(Registered TradeMark) 740, Nimonic(Registered TradeMark) 263, Incoloy(Registered TradeMark) MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.

  4. Spatial Statistics for Segmenting Histological Structures in H&E Stained Tissue Images.

    PubMed

    Nguyen, Luong; Tosun, Akif Burak; Fine, Jeffrey L; Lee, Adrian V; Taylor, D Lansing; Chennubhotla, S Chakra

    2017-07-01

    Segmenting a broad class of histological structures in transmitted light and/or fluorescence-based images is a prerequisite for determining the pathological basis of cancer, elucidating spatial interactions between histological structures in tumor microenvironments (e.g., tumor infiltrating lymphocytes), facilitating precision medicine studies with deep molecular profiling, and providing an exploratory tool for pathologists. This paper focuses on segmenting histological structures in hematoxylin- and eosin-stained images of breast tissues, e.g., invasive carcinoma, carcinoma in situ, atypical and normal ducts, adipose tissue, and lymphocytes. We propose two graph-theoretic segmentation methods based on local spatial color and nuclei neighborhood statistics. For benchmarking, we curated a data set of 232 high-power field breast tissue images together with expertly annotated ground truth. To accurately model the preference for histological structures (ducts, vessels, tumor nets, adipose, etc.) over the remaining connective tissue and non-tissue areas in ground truth annotations, we propose a new region-based score for evaluating segmentation algorithms. We demonstrate the improvement of our proposed methods over the state-of-the-art algorithms in both region- and boundary-based performance measures.

  5. Umbrella occlusion of persistent arterial duct in children under two years.

    PubMed Central

    Gatzoulis, M A; Rigby, M L; Redington, A N

    1994-01-01

    OBJECTIVE--To assess the use of trans-catheter occlusion of a persistent arterial duct in symptomatic children < 2 years of age. DESIGN--Descriptive study of selected, non-randomised infants with persistent arterial duct who underwent attempted umbrella occlusion. SETTING--Tertiary referral centre. PATIENTS--Between June 1990 and April 1993, 29 young children with a symptomatic persistent arterial duct underwent attempted transcatheter occlusion. Their age ranged from 1.5 to 23 months, with the youngest infant weighing 2.9 kg. The diagnosis was established before operation in all patients by cross sectional echocardiography. INTERVENTION--Transcatheter occlusion of a haemodynamically important persistent arterial duct was performed with the Rashkind ductal umbrella. In the past year the front loading technique has been used to place the 12 mm umbrella through a 6 F (French) sheath and the 17 mm device through a 8 F sheath so extending the indications for their use. RESULTS--Umbrellas were successfully placed in 25 (86.2%) infants and there was symptomatic improvement in all. There were no deaths or severe complications. The four failures occurred early in the series. They were caused by kinking of the 11 F sheath in two cases and embolisation into the left pulmonary artery in one case. The procedure was abandoned in the fourth case because of a large duct. Only three of the 25 patients had small residual shunts at one year follow up (all with 17 mm devices) but no stenosis or turbulence was noted in any of the patients. CONCLUSION--The transcatheter occlusion of persistent arterial duct in young children with symptoms is a safe alternative to surgery. The new front loading umbrella technique enables successful ductal closure in even smaller infants than earlier devices. Images PMID:7833196

  6. Application of the RNS3D Code to a Circular-Rectangular Transition Duct With and Without Inlet Swirl and Comparison with Experiments

    NASA Technical Reports Server (NTRS)

    Cavicchi, Richard H.

    1999-01-01

    Circular-rectangular transition ducts are used between engine exhausts and nozzles with rectangular cross sections that are designed for high performance aircraft. NASA Glenn Research Center has made experimental investigations of a series of circular-rectangular transition ducts to provide benchmark flow data for comparison with numerical calculations. These ducts are all designed with superellipse cross sections to facilitate grid generation. In response to this challenge, the three-dimensional RNS3D code has been applied to one of these transition ducts. This particular duct has a length-to-inlet diameter ratio of 1.5 and an exit-plane aspect ratio of 3.0. The inlet Mach number is 0.35. Two GRC experiments and the code were run for this duct without inlet swirl. One GRC experiment and the code were also run with inlet swirl. With no inlet swirl the code was successful in predicting pressures and secondary flow conditions, including a pair of counter-rotating vortices at both sidewalls of the exit plane. All these phenomena have been reported from the two GRC experiments. However, these vortices were suppressed in the one experiment when inlet swirl was used; whereas the RNS3D code still predicted them. The experiment was unable to provide data near the sidewalls, the very region where the vortices were predicted.

  7. THE MANAGEMENT OF CHYLOTHORAX

    PubMed Central

    Connolly, John E.; Smith, John W.

    1959-01-01

    Chylothorax is readily diagnosed from the characteristic qualities of the effusion. Treatment should initially be conservative, consisting of multiple aspirations followed, if necessary, by suction drainage. Approximately half of the patients will not respond to these measures, and direct ligation and division of the duct is necessary for cure. This operation is most readily carried out through the right chest, the thoracic duct being ligated just above the diaphragm. In cases in which the duct is surrounded by tumor, radiotherapy to the mediastinum is often successful in controlling the reaccumulation of chyle, but irradiation is generally not recommended until after a tissue diagnosis has been made by thoracotomy. Nutritional problems are often concomitants of chylothorax. ImagesFigure 1 (Case 1).Figure 2 (Case 1).Figure 3 (Case 2).Figure 4 (Case 2).Figure 5 (Case 3).Figure 6 (Case 3). PMID:13671361

  8. [Retrograde pancreatic duct imaging and surgical tactics in hemorrhagic necrotizing pancreatitis. Preliminary report].

    PubMed

    Gebhardt, C; Gall, F P; Lux, G; Riemann, J; Link, W

    1983-12-01

    In patients with haemorrhagic necrotizing pancreatitis who are scheduled for surgery we have been carrying out a preoperative retrograde investigation of the pancreatic duct system for the past months. The results in, to date, ten patients revealed four different morphological findings of importance for the surgical tactic: 1. A normal pancreatic duct system with no signs of fistulae: only peripancreatic necrosectomy is required. - 2. Contrast medium leaks via a ductal fistula: left resection including the removal of the fistulous area must be done. - 3. Normal duct system with complete segmental parenchymal staining, representing total necrosis in this region: left resection of the pancreas. - 4. Duodenoscopically demonstrable perforation into the duodenum of a necrotic cavity in the head of the pancreas: conservative management only, no surgery, since this lesion resulting in drainage of the necrotic cavity into the bowel permits self-healing, while the site of the perforation within the necrotic wall cannot be dealt with by surgery. - The experience gained so far indicates that the surgical tactic can be determined with greater selectivity by the use of ERP.

  9. Simulation System for Training in Laparoscopic Surgery

    NASA Technical Reports Server (NTRS)

    Basdogan, Cagatay; Ho, Chih-Hao

    2003-01-01

    A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

  10. A two-microphone method for the determination of the mode amplitude distribution in high-frequency ducted broadband sound fields.

    PubMed

    Joseph, P F

    2017-10-01

    This paper describes a measurement technique that allows the modal amplitude distribution to be determined in ducts with mean flow and reflections. The method is based only on measurements of the acoustic pressure two-point coherence at the duct wall. The technique is primarily applicable to broadband sound fields in the high frequency limit and whose mode amplitudes are mutually incoherent. The central assumption underlying the technique is that the relative mode amplitude distribution is independent of frequency. The two-microphone method proposed in this paper is also used to determine the transmitted sound power and far field pressure directivity.

  11. Modulation of Sodium/Iodide Symporter Expression in the Salivary Gland

    PubMed Central

    La Perle, Krista M.D.; Kim, Dong Chul; Hall, Nathan C.; Bobbey, Adam; Shen, Daniel H.; Nagy, Rebecca S.; Wakely, Paul E.; Lehman, Amy; Jarjoura, David

    2013-01-01

    Background Physiologic iodide-uptake, mediated by the sodium/iodide symporter (NIS), in the salivary gland confers its susceptibility to radioactive iodine–induced damage following 131I treatment of thyroid cancer. Subsequent quality of life for thyroid cancer survivors can be decreased due to recurrent sialoadenitis and persistent xerostomia. NIS expression at the three principal salivary duct components in various pathological conditions was examined to better our understanding of NIS modulation in the salivary gland. Methods NIS expression was evaluated by immunohistochemistry in human salivary gland tissue microarrays constructed of normal, inflamed, and neoplastic salivary tissue cores. Cumulative 123I radioactivity reflecting the combination of NIS activity with clearance of saliva secretion in submandibular and parotid salivary glands was evaluated by single-photon emission computed tomography/computed tomography imaging 24 hours after 123I administration in 50 thyroid cancer patients. Results NIS is highly expressed in the basolateral membranes of the majority of striated ducts, yet weakly expressed in few intercalated and excretory duct cells. The ratio of 123I accumulation between parotid and submandibular glands is 2.38±0.19. However, the corresponding ratio of 123I accumulation normalized by volume of interest is 1.19±0.06. The percentage of NIS-positive striated duct cells in submandibular salivary glands was statistically greater than in parotid salivary glands, suggesting a higher clearance rate of saliva secretion in submandibular salivary glands. NIS expression in striated ducts was heterogeneously decreased or absent in sialoadenitis. Most ductal salivary gland tumors did not express NIS. However, Warthin's tumors of striated duct origin exhibited consistent and intense NIS staining, corresponding with radioactive iodine uptake. Conclusions NIS expression is tightly modulated during the transition of intercalated to striated ducts and striated to excretory ducts in salivary ductal cells. NIS expression in salivary glands is decreased during inflammation and tumor formation. Further investigation may identify molecular targets and/or pharmacologic agents that allow selective inhibition of NIS expression/activity in salivary glands during radioactive iodine treatment. PMID:23441638

  12. Utility of Diffusion-Weighted MRI to Detect Changes in Liver Diffusion in Benign and Malignant Distal Bile Duct Obstruction: The Influence of Choice of b-Values.

    PubMed

    Karan, Belgin; Erbay, Gurcan; Koc, Zafer; Pourbagher, Aysin; Yildirim, Sedat; Agildere, Ahmet Muhtesem

    2016-11-01

    The study sought to evaluate the potential of diffusion-weighted magnetic resonance imaging to detect changes in liver diffusion in benign and malignant distal bile duct obstruction and to investigate the effect of the choice of b-values on apparent diffusion coefficient (ADC). Diffusion-weighted imaging was acquired with b-values of 200, 600, 800, and 1000 s/mm 2 . ADC values were obtained in 4 segments of the liver. The mean ADC values of 16 patients with malignant distal bile duct obstruction, 14 patients with benign distal bile duct obstruction, and a control group of 16 healthy patients were compared. Mean ADC values for 4 liver segments were lower in the malignant obstruction group than in the benign obstruction and control groups using b = 200 s/mm 2 (P < .05). Mean ADC values of the left lobe medial and lateral segments were lower in the malignant obstruction group than in the benign obstructive and control groups using b = 600 s/mm 2 (P < .05). Mean ADC values of the right lobe posterior segment were lower in the malignant and benign obstruction groups than in the control group using b = 1000 s/mm 2 (P < .05). Using b = 800 s/mm 2 , ADC values of all 4 liver segments in each group were not significantly different (P > .05). There were no correlations between the ADC values of liver segments and liver function tests. Measurement of ADC shows good potential for detecting changes in liver diffusion in patients with distal bile duct obstruction. Calculated ADC values were affected by the choice of b-values. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Differentiating immunoglobulin g4-related sclerosing cholangitis from hilar cholangiocarcinoma.

    PubMed

    Tabata, Taku; Kamisawa, Terumi; Hara, Seiichi; Kuruma, Sawako; Chiba, Kazuro; Kuwata, Go; Fujiwara, Takashi; Egashira, Hideto; Koizumi, Koichi; Fujiwara, Junko; Arakawa, Takeo; Momma, Kumiko; Kurata, Masanao; Honda, Goro; Tsuruta, Koji; Itoi, Takao

    2013-03-01

    Few studies have differentiated immunoglobulin G (IgG) 4-related sclerosing cholangitis (IgG4-SC) from hilar cholangiocarcinoma (CC). Thus, we sought to investigate useful features for differentiating IgG4-SC from hilar CC. We retrospectively compared clinical, serological, imaging, and histological features of six patients with IgG4-SC and 42 patients with hilar CC. In patients with hilar CC, obstructive jaundice was more frequent (p<0.01), serum total bilirubin levels were significantly higher (p<0.05), serum CA19-9 levels were significantly higher (p<0.01), and serum duke pancreatic monoclonal antigen type 2 levels were frequently elevated (p<0.05). However, in patients with IgG4-SC, the serum IgG (p<0.05) and IgG4 (p<0.01) levels were significantly higher and frequently elevated. The pancreas was enlarged in all IgG4-SC patients but only in 17% of hilar CC patients (p<0.01). Salivary and/or lacrimal gland swelling was detected in only 50% of IgG4-SC patients (p<0.01). Endoscopic retrograde cholangiography revealed that the hilar or hepatic duct was completely obstructed in 83% of hilar CC patients (p<0.01). Lower bile duct stenosis, apart from hilar bile duct stenosis, was more frequent in IgG4-SC patients (p<0.01). Bile duct wall thickening in areas without stenosis was more frequent in IgG4-SC patients (p<0.01). An integrated diagnostic approach based on clinical, serological, imaging, and histological findings is necessary to differentiate IgG4-SC from hilar CC.

  14. Cholangiocarcinoma…Or Not?

    PubMed Central

    Kenny, Patrick; Kerns, Tamie

    2013-01-01

    Introduction Cholangiocarcinoma includes all tumors originating in the epithelium of the bile duct and is the ninth most common gastrointestinal tract cancer. Metastatic disease may also rarely be present in the common bile duct. We present a case of metastatic malignant melanoma presenting as obstructive hepatitis and initially was thought to be and was almost treated as cholangiocarcinoma prior to adequate tissue sampling. Case Report A 76-year-old man presented with nausea, vomiting, and painless jaundice. He had a mixed hepatocellular pattern with transaminases and alkaline phosphatase greater than 1000 and total bilirubin of 12. A three-phase liver CT showed an enhancing mass within a dilated common bile duct and extension of the mass into the right and left intrahepatic bile ducts. He subsequently underwent ERCP with bile duct brushings and stent placement. Bile duct brushings showed benign reactive ductal epithelial cells. An endoscopic ultrasound with fine needle aspiration of the bile duct mass was performed. Pathology was negative for CK7, CK20, and positive for S100, Pan-melanoma, and negative for BRAF. No suspicious skin lesions were seen on close inspection by a dermatologist. However, two years prior the patient was diagnosed with cutaneous malignant melanoma in situ that was surgically resected. Thus, it was felt that this case represented metastatic melanoma to the bile duct. Due to significant comorbidities the patient was determined to be a poor surgical candidate. He has completed first line therapy for unresectable multiple melanoma with four rounds of ipilimumab. Discussion Pathologic diagnosis of cholangiocarcinoma is often difficult to obtain from ERCP secondary to paucicellularity of these tumors and with no imaging modality that is specific for cholangiocarcinma. The hepatobiliary tract is a possible, though relatively rare, location for metastatic focus of malignant melanoma and should be considered in a patient with a history of melanoma and no tissue diagnosis after ERCP. There are multiple case reports of metastatic melanoma to the ampula of Vater causing obstructive hepatitis, but only 10 reports of disease found in the common bile duct. This case highlights the importance of obtaining tissue from suspected malignant lesions using various forms of endoscopy to ensure proper treatment and prolonged survival.

  15. The potential for CMCs to replace superalloys in engine exhaust ducts

    NASA Astrophysics Data System (ADS)

    Roth, Richard; Clark, Joel P.; Field, Frank R.

    1994-01-01

    The Materials Systems Laboratory at the Massachusetts Institute of Technology has conducted research to develop decision tools that can facilitate materials selection and provide a deeper understanding of the design tradeoffs that occur when choosing among advanced aerospace materials for high-temperature applications. As an illustration of the use of these tools, this paper describes research done to evaluate the material alternatives currently under consideration for exhaust ducts in aircraft gas turbine engines. Although nickel-based superalloys currently prevail for this application, the increasing temperatures of modern engines are necessitating the usage of higher temperature materials.

  16. The Detection of Radiated Modes from Ducted Fan Engines

    NASA Technical Reports Server (NTRS)

    Farassat, F.; Nark, Douglas M.; Thomas, Russell H.

    2001-01-01

    The bypass duct of an aircraft engine is a low-pass filter allowing some spinning modes to radiate outside the duct. The knowledge of the radiated modes can help in noise reduction, as well as the diagnosis of noise generation mechanisms inside the duct. We propose a nonintrusive technique using a circular microphone array outside the engine measuring the complex noise spectrum on an arc of a circle. The array is placed at various axial distances from the inlet or the exhaust of the engine. Using a model of noise radiation from the duct, an overdetermined system of linear equations is constructed for the complex amplitudes of the radial modes for a fixed circumferential mode. This system of linear equations is generally singular, indicating that the problem is illposed. Tikhonov regularization is employed to solve this system of equations for the unknown amplitudes of the radiated modes. An application of our mode detection technique using measured acoustic data from a circular microphone array is presented. We show that this technique can reliably detect radiated modes with the possible exception of modes very close to cut-off.

  17. Performance prediction of a ducted rocket combustor

    NASA Astrophysics Data System (ADS)

    Stowe, Robert

    2001-07-01

    The ducted rocket is a supersonic flight propulsion system that takes the exhaust from a solid fuel gas generator, mixes it with air, and burns it to produce thrust. To develop such systems, the use of numerical models based on Computational Fluid Dynamics (CFD) is increasingly popular, but their application to reacting flow requires specific attention and validation. Through a careful examination of the governing equations and experimental measurements, a CFD-based method was developed to predict the performance of a ducted rocket combustor. It uses an equilibrium-chemistry Probability Density Function (PDF) combustion model, with a gaseous and a separate stream of 75 nm diameter carbon spheres to represent the fuel. After extensive validation with water tunnel and direct-connect combustion experiments over a wide range of geometries and test conditions, this CFD-based method was able to predict, within a good degree of accuracy, the combustion efficiency of a ducted rocket combustor.

  18. A modal separation measurement technique for broadband noise propagating inside circular ducts

    NASA Technical Reports Server (NTRS)

    Kerschen, E. J.; Johnston, J. P.

    1981-01-01

    A measurement technique which separates broadband noise propagating inside circular ducts into the acoustic duct modes is developed. The technique is also applicable to discrete frequency noise. The acoustic modes are produced by weighted combinations of the instantaneous outputs of microphones spaced around the duct circumference. The technique is compared with the cross spectral density approach presently available and found to have certain advantages, and disadvantages. Considerable simplification of both the new technique and the cross spectral density approach occurs when no correlation exists between different circumferential mode orders. The properties leading to uncorrelated modes and experimental tests which verify this condition are discussed. The modal measurement technique is applied to the case of broadband noise generated by flow through a coaxial obstruction (nozzle or orifice) in a pipe. Different circumferential mode orders are shown to be uncorrelated for this type of noise source.

  19. Stensen's duct injuries: the role of sialendoscopy and adjuvant botulinum toxin injection

    PubMed Central

    Wierzbicka, Małgorzata; Szyfter, Witold

    2013-01-01

    Introduction Stensen's duct injuries are uncommon but troublesome sequelae of facial surgery or other external traumas. Aim To investigate the feasibility of sialendoscopic control of Stensen's duct in iatrogenic injuries and the efficiency of botulinum toxin adjuvant therapy. Material and methods In 2008 and 2010, 5 patients with parotid sialoceles or fistulas, infrequent complications after plastic surgery or trauma, were treated in a single institution, Poznan University of Medical Sciences ENT Department. The group consisted of 5 patients with diagnosed Stensen's duct injuries, which were post-surgery and post-traumatic sequelae. All were treated by means of open surgery. Botulinum toxin injection was administered during the procedure to decrease the saliva secretion and to improve the healing process. A sialendoscopy was performed to control the lumen of the junction after the duct injury was repaired. Results Complete healing of the fistulas and sialoceles after the reparative surgery followed by a single botulinum toxin application was observed in all patients within 10-14 days. No side effects were noticed. Conclusions Our findings suggest that sialendoscopy is a valuable tool and an important step of control in the surgery of parotid duct injuries and the injection of botulinum toxin is an effective and safe second-line treatment. PMID:23837095

  20. A unifying concept: pancreatic ductal anatomy both predicts and determines the major complications resulting from pancreatitis.

    PubMed

    Nealon, William H; Bhutani, Manoop; Riall, Taylor S; Raju, Gottumukkala; Ozkan, Orhan; Neilan, Ryan

    2009-05-01

    Precepts about acute pancreatitis, necrotizing pancreatitis, and pancreatic fluid collections or pseudocyst rarely include the impact of pancreatic ductal injuries on their natural course and outcomes. We previously examined and established a system to categorize ductal changes. We sought a unifying concept that may predict course and direct therapies in these complex patients. We use our system categorizing ductal changes in pseudocyst of the pancreas and severe necrotizing pancreatitis (type I, normal duct; type II, duct stricture; type III, duct occlusion or "disconnected duct"; and type IV, chronic pancreatitis). From 1985 to 2006, a policy was implemented of routine imaging (cross-sectional, endoscopic retrograde cholangiopancreatography, or magnetic resonance cholangiopancreatography). Clinical outcomes were measured. Among 563 patients with pseudocyst, 142 resolved spontaneously (87% of type I, 5% of type II, and no type III, and 3% of type IV). Percutaneous drainage was successful in 83% of type I, 49% of type II, and no type III or type IV. Among 174 patients with severe acute pancreatitis percutaneous drainage was successful in 64% of type I, 38% of type II, and no type III. Operative debridement was required in 39% of type I and 83% and 85% of types II and III, respectively. Persistent fistula after debridement occurred in 27%, 54%, and 85% of types I, II, and III ducts, respectively. Late complications correlated with duct injury. Pancreatic ductal changes predict spontaneous resolution, success of nonoperative measures, and direct therapies in pseudocyst. Ductal changes also predict patients with necrotizing pancreatitis who are most likely to have immediate and delayed complications.

  1. Local Heat Transfer for Finned-Tube Heat Exchangers using Oval Tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, James Edward; Sohal, Manohar Singh

    2000-08-01

    This paper presents the results of an experimental study of forced convection heat transfer in a narrow rectangular duct fitted with either a circular tube or an elliptical tube in crossflow. The duct was designed to simulate a single passage in a fin-tube heat exchanger. Heat transfer measurements were obtained using a transient technique in which a heated airflow is suddenly introduced to the test section. High-resolution local fin-surface temperature distributions were obtained at several times after initiation of the transient using an imaging infrared camera. Corresponding local fin-surface heat transfer coefficient distributions were then calculated from a locally appliedmore » one-dimensional semi-infinite inverse heat conduction model. Heat transfer results were obtained over an airflow rate ranging from 1.56 x 10-3 to 15.6 x 10-3 kg/s. These flow rates correspond to a duct-height Reynolds number range of 630 – 6300 with a duct height of 1.106 cm and a duct width-toheight ratio, W/H, of 11.25. The test cylinder was sized such that the diameter-to-duct height ratio, D/H is 5. The elliptical tube had an aspect ratio of 3:1 and a/H equal to 4.33. Results presented in this paper reveal visual and quantitative details of local fin-surface heat transfer distributions in the vicinity of circular and oval tubes and their relationship to the complex horseshoe vortex system that forms in the flow stagnation region. Fin surface stagnation-region Nusselt numbers are shown to be proportional to the square-root of Reynolds number.« less

  2. Complicated bile duct stones

    PubMed Central

    Roy, Ashwin; Martin, Derrick

    2013-01-01

    Common bile duct stones (CBDSs) are solid deposits that can either form within the gallbladder or migrate to the common bile duct (CBD), or form de novo in the biliary tree. In the USA around 15% of the population have gallstones and of these, 3% present with symptoms annually. Because of this, there have been major advancements in the management of gallstones and related conditions. Management is based on the patient's risk profile; young and healthy patients are likely to be recommended for surgery and elderly patients with comorbidities are usually recommended for endoscopic procedures. Imaging of gallstones has advanced in the last 30 years with endoscopic retrograde cholangiopancreatography evolving from a diagnostic to a therapeutic procedure in removing CBDSs. We present a complicated case of a patient with a CBDS and periampullary diverticulum and discuss the techniques used to diagnose and remove the stone from the biliary system. PMID:23946532

  3. [Choledocholithiasis and pregnancy. Hybrid laparo-endoscopic treatment in one step].

    PubMed

    Valadez-Caballero, David; González-Santamaría, Roberto; Soto-Mendoza, Héctor; Alberto Blanco-Figueroa, Jorge; Flores-Pantoja, Juan Manuel

    2014-01-01

    Complications associated with choledocholithiasis are uncommon during pregnancy. However, when it occurs, the morbidity and mortality related for the product and the mother increases, so a proper treatment is imperative in these patients. A 25-year-old pregnant woman on her second trimester. The current condition was started four days prior to the hospital admission with abdominal pain in the right upper quadrant with nausea and vomit.Twenty-four hours later jaundice and dark urine is observed. Physical examination shows scleral jaundice, right upper quadrant abdominal pain without peritoneal irritation. Uterus at umbilicus level without uterine activity. Uterus at umbilicus level without uterine activity. Laboratory tests showed elevated bilirubin and transaminases without leukocytosis; ultrasound reported live intrauterine unique product, with a heart rate of 128 beats per minute, gallbladder with multiple images inside that cast acoustic shadowing, and a 10 mm common bile duct dilated bile duct with dilatation of intrahepatic bile ducts. It was perform laparoscopic cholecystectomy with intraoperative cholangiography and placement of a transcystic jaguar guide for selective cannulation of the common bile duct. Intraoperative endoscopic retrograde cholangiopancreatography was performed with endoscopic stone extraction. The outcome was satisfactory with a hospital discharge at 48 hours. Current evidence has shown that the combined use of laparoscopy and therapeutic endoscopic cholangiography in one step is effective for the treatment of choledocholithiasis, decreasing the risk of complications associated with cannulation of the bile duct.

  4. Investigation of advanced counterrotation blade configuration concepts for high speed turboprop systems. Task 5: Unsteady counterrotation ducted propfan analysis

    NASA Technical Reports Server (NTRS)

    Hall, Edward J.; Delaney, Robert A.

    1993-01-01

    The primary objective of this study was the development of a time-marching three-dimensional Euler/Navier-Stokes aerodynamic analysis to predict steady and unsteady compressible transonic flows about ducted and unducted propfan propulsion systems employing multiple blade rows. The computer codes resulting from this study are referred to as ADPAC-AOAR\\CR (Advanced Ducted Propfan Analysis Codes-Angle of Attack Coupled Row). This document is the final report describing the theoretical basis and analytical results from the ADPAC-AOACR codes developed under task 5 of NASA Contract NAS3-25270, Unsteady Counterrotating Ducted Propfan Analysis. The ADPAC-AOACR Program is based on a flexible multiple blocked grid discretization scheme permitting coupled 2-D/3-D mesh block solutions with application to a wide variety of geometries. For convenience, several standard mesh block structures are described for turbomachinery applications. Aerodynamic calculations are based on a four-stage Runge-Kutta time-marching finite volume solution technique with added numerical dissipation. Steady flow predictions are accelerated by a multigrid procedure. Numerical calculations are compared with experimental data for several test cases to demonstrate the utility of this approach for predicting the aerodynamics of modern turbomachinery configurations employing multiple blade rows.

  5. Sound Insulation in a Hollow Pipe with Subwavelength Thickness

    NASA Astrophysics Data System (ADS)

    Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun

    2017-03-01

    Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers.

  6. Sound Insulation in a Hollow Pipe with Subwavelength Thickness

    PubMed Central

    Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun

    2017-01-01

    Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers. PMID:28272486

  7. Sound Insulation in a Hollow Pipe with Subwavelength Thickness.

    PubMed

    Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun

    2017-03-08

    Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers.

  8. Investigation of advanced counterrotation blade configuration concepts for high speed turboprop systems. Task 5: Unsteady counterrotation ducted propfan analysis. Computer program user's manual

    NASA Technical Reports Server (NTRS)

    Hall, Edward J.; Delaney, Robert A.; Adamczyk, John J.; Miller, Christopher J.; Arnone, Andrea; Swanson, Charles

    1993-01-01

    The primary objective of this study was the development of a time-marching three-dimensional Euler/Navier-Stokes aerodynamic analysis to predict steady and unsteady compressible transonic flows about ducted and unducted propfan propulsion systems employing multiple blade rows. The computer codes resulting from this study are referred to as ADPAC-AOACR (Advanced Ducted Propfan Analysis Codes-Angle of Attack Coupled Row). This report is intended to serve as a computer program user's manual for the ADPAC-AOACR codes developed under Task 5 of NASA Contract NAS3-25270, Unsteady Counterrotating Ducted Propfan Analysis. The ADPAC-AOACR program is based on a flexible multiple blocked grid discretization scheme permitting coupled 2-D/3-D mesh block solutions with application to a wide variety of geometries. For convenience, several standard mesh block structures are described for turbomachinery applications. Aerodynamic calculations are based on a four-stage Runge-Kutta time-marching finite volume solution technique with added numerical dissipation. Steady flow predictions are accelerated by a multigrid procedure. Numerical calculations are compared with experimental data for several test cases to demonstrate the utility of this approach for predicting the aerodynamics of modern turbomachinery configurations employing multiple blade rows.

  9. Application of finite difference techniques to noise propagation in jet engine ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1973-01-01

    A finite difference formulation is presented for wave propagation in a rectangular two-dimensional duct without steady flow. The difference technique, which should be used in the study of acoustically treated inlet and exhausts ducts used in turbofan engines, can readily handle acoustical flow field complications such as axial variations in wall impedance and cross-section area. In the numerical analysis, the continuous acoustic field is lumped into a series of grid points in which the pressure and velocity at each grid point are separated into real and imaginary terms. An example calculation is also presented for the sound attenuation in a two-dimensional straight soft-walled suppressor.

  10. Application of finite difference techniques to noise propagation in jet engine ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1973-01-01

    A finite difference formulation is presented for wave propagation in a rectangular two-dimensional duct without steady flow. The difference technique, which should be useful in the study of acoustically treated inlet and exhausts ducts used in turbofan engines, can readily handle acoustical flow field complications such as axial variations in wall impedance and cross section area. In the numerical analysis, the continuous acoustic field is lumped into a series of grid points in which the pressure and velocity at each grid point are separated into real and imaginary terms. An example calculation is also presented for the sound attenuation in a two-dimensional straight soft-walled suppressor.

  11. Human thoracic duct in vitro: diameter-tension properties, spontaneous and evoked contractile activity.

    PubMed

    Telinius, Niklas; Drewsen, Nanna; Pilegaard, Hans; Kold-Petersen, Henrik; de Leval, Marc; Aalkjaer, Christian; Hjortdal, Vibeke; Boedtkjer, Donna Briggs

    2010-09-01

    The current study characterizes the mechanical properties of the human thoracic duct and demonstrates a role for adrenoceptors, thromboxane, and endothelin receptors in human lymph vessel function. With ethical permission and informed consent, portions of the thoracic duct (2-5 cm) were resected and retrieved at T(7)-T(9) during esophageal and cardia cancer surgery. Ring segments (2 mm long) were mounted in a myograph for isometric tension (N/m) measurement. The diameter-tension relationship was established using ducts from 10 individuals. Peak active tension of 6.24 +/- 0.75 N/m was observed with a corresponding passive tension of 3.11 +/- 0.67 N/m and average internal diameter of 2.21 mm. The equivalent active and passive transmural pressures by LaPlace's law were 47.3 +/- 4.7 and 20.6 +/- 3.2 mmHg, respectively. Subsequently, pharmacology was performed on rings from 15 ducts that were normalized by stretching them until an equivalent pressure of 21 mmHg was calculable from the wall tension. At low concentrations, norepinephrine, endothelin-1, and the thromboxane-A(2) analog U-46619 evoked phasic contractions (analogous to lymphatic pumping), whereas at higher contractions they induced tonic activity (maximum tension values of 4.46 +/- 0.63, 5.90 +/- 1.4, and 6.78 +/- 1.4 N/m, respectively). Spontaneous activity was observed in 44% of ducts while 51% of all the segments produced phasic contractions after agonist application. Acetylcholine and bradykinin relaxed norepinephrine preconstrictions by approximately 20% and approximately 40%, respectively. These results demonstrate that the human thoracic duct can develop wall tensions that permit contractility to be maintained across a wide range of transmural pressures and that isolated ducts contract in response to important vasoactive agents.

  12. Fast subsurface fingerprint imaging with full-field optical coherence tomography system equipped with a silicon camera.

    PubMed

    Auksorius, Egidijus; Boccara, A Claude

    2017-09-01

    Images recorded below the surface of a finger can have more details and be of higher quality than the conventional surface fingerprint images. This is particularly true when the quality of the surface fingerprints is compromised by, for example, moisture or surface damage. However, there is an unmet need for an inexpensive fingerprint sensor that is able to acquire high-quality images deep below the surface in short time. To this end, we report on a cost-effective full-field optical coherent tomography system comprised of a silicon camera and a powerful near-infrared LED light source. The system, for example, is able to record 1.7  cm×1.7  cmen face images in 0.12 s with the spatial sampling rate of 2116 dots per inch and the sensitivity of 93 dB. We show that the system can be used to image internal fingerprints and sweat ducts with good contrast. Finally, to demonstrate its biometric performance, we acquired subsurface fingerprint images from 240 individual fingers and estimated the equal-error-rate to be ∼0.8%. The developed instrument could also be used in other en face deep-tissue imaging applications because of its high sensitivity, such as in vivo skin imaging. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. Diagnostic value of T1-weighted gradient-echo in-phase images added to MRCP in differentiation of hepatolithiasis and intrahepatic pneumobilia.

    PubMed

    Erden, Ayşe; Haliloğlu, Nuray; Genç, Yasemin; Erden, Ilhan

    2014-01-01

    The purpose of this article is to determine the added diagnostic value of T1-weighted gradient-echo in-phase images obtained during MRCP in the detection and differentiation of hepatolithiasis and intrahepatic pneumobilia. Intrahepatic bile ducts in 47 patients were scored in terms of their possibility of containing biliary stone and air. MRI was performed with a 1-T system for 32 patients and with a 3-T system for 15 patients. Two radiologists independently reviewed two sets of MRI scans: set 1 included T2-weighted MRCP images, and set 2 included T2-weighted MRCP images plus T1-weighted gradient-echo in-phase images. The diagnostic performances of set 1 and set 2 in the evaluation of the bile ducts containing air or stone and bile ducts containing neither of them were analyzed using the area under the receiver operating characteristic curve (AUC) for clustered data. The sensitivities and specificities of both image sets to detect intrahepatic stone or air were also calculated and compared. For the diagnosis of hepatolithiasis, the AUC obtained from set 2 (0.983) was significantly higher than that obtained from set 1 (0.879; p = 0.037). For the diagnosis of pneumobilia, the AUC obtained from set 2 (0.965) was also significantly higher than that of set 1 (0.765; p = 0.002). With use of percutaneous transhepatic cholangiography, ERCP, and CT as the reference standards, the sensitivity of set 2 (97.1%; 95% CI, 91.1-100%) was significantly higher than that of set 1 (74.3%; 95% CI, 56.7-91.9%) in detecting intrahepatic stones (p = 0.011). For the detection of pneumobilia, the sensitivity of set 2 (98.5%; 95% CI, 95.4-100%) was also significantly higher than that of set 1 (70.8%; 95% CI, 57.7-83.3%; p = 0.000). The addition of T1-weighted gradient-echo in-phase images to standard MRCP sequences improves the detection and differentiation of hepatolithiasis and intrahepatic pneumobilia.

  14. Use of LigaSure™ on bile duct in rats: an experimental study.

    PubMed

    Marte, Antonio; Pintozzi, Lucia

    2017-08-01

    The closure of a cystic duct during cholecystectomy by means of radiofrequency is still controversial. We report our preliminary experimental results with the use of LigaSure™ on common bile duct in rats. Thirty Wistar rats weighing 70 to 120 g were employed for this study. The animals were all anesthetized with intraperitoneal ketamine and then divided into three groups. The first group (10 rats, Group C) underwent only laparotomy and isolation of the common bile duct. The second (10 rats, Group M) underwent laparotomy and closure of the common bile duct (CBD) with monopolar coagulation. The third group (10 rats, Group L) underwent laparotomy and sealing of the common bile duct with two application of LigaSureTM. Afterwards, all rats were kept in comfortable cages and were administered dibenzamine for five days. They were all sacrificed on day 20. Through a laparotomy, the liver and bile duct were removed for histological examination. Blood samples were obtained to dose bilirubin, amylase and transaminase levels. Mortality rate was 0 in the control group (C), 3/10 rats in group M and 0 in group L. In group L, the macroscopic examination showed a large choledochocele (3-3.5 × 1.5 cm) with few adhesions. At the histological examination there was optimal sealing of the common bile duct in 9/10 rats. In group M, 2/10 rats had liver abscesses, 3/10 rats had choledochocele and 5/10 rats, biliary peritonitis. There was intense tissue inflammation and the dissection was difficult. Analyses of blood samples showed an increase in total bilirubin, aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in groups M and L. The preliminary results of our study confirm that radiofrequency can be safely used for the closure of the common bile duct. The choledochocele obtained with this technique could represent a good experimental model. These results could be a further step for using the LigaSureTM in clipless cholecystectomy.

  15. [The 455th case: swollen leg, jaundice and mental disturbance].

    PubMed

    Dong, R; Weng, L; Guo, T; Zhu, T N; Zhao, J L; Wu, Q J; Zeng, X F

    2017-04-01

    A 17-year-old young man with a history of swollen leg and intermittent jaundice was presented to Peking Union Medical College Hospital with acute fever and mental disturbance. He developed deep venous thrombosis, acute myocardial infarction and plantar skin necrosis during the past four years, and was presented with an acute episode of fever, thrombocytopenia, acute kidney injury, acute myocardial infarction, mental disturbance, and obstructive jaundice. Laboratory tests showed schistocytes on peripheral blood smear.High titer of antiphospholipid antibodies was detected.Strikingly, the activity of a disintegrin and metalloprotease with a thrombospondin type 1 motif, member 13 (ADAMTS13)was significantly decreased without the production of inhibitors. Images indicated stenosis of the common bile duct, common hepatic duct, and cystic duct, which caused dilation of bile ducts and the gall bladder. Corticosteroids and anticoagulation therapy were effective at first, but the disease relapsedonce the corticosteroids tapered down. Plasma exchange was administrated for 17 times, which was effective temporarily during this episode. Methylprednisolone pulse therapy, intravenous immunoglobulin, rituximab, anticoagulation therapy, and bile drainage, were all tried but still could not control the disease. The patient's family agreed to withdraw treatment after he developed septic shock.

  16. Direct retrograde cholangioscopy with a new prototype double-bending cholangioscope.

    PubMed

    Beyna, Torsten; Farnik, Harald; Sarrazin, Christoph; Gerges, Christian; Neuhaus, Horst; Albert, Jörg G

    2016-10-01

    Direct retrograde cholangioscopy (DRC) enables high quality video imaging of the bile ducts and allows intraductal treatment with optical control. We evaluated the feasibility, success, and complications of a new third-generation prototype cholangioscope. All consecutive patients from two tertiary endoscopy centers who had undergone DRC with the prototype were included. Indications for DRC were: evaluation of indeterminate strictures, filling defects, and complex bile duct stones. Technical success was investigated in terms of indication and treatment performed. All adverse events were recorded. DRC with the prototype was performed in 74 patients. Therapeutic interventions included laser or electrohydraulic lithotripsy and stone removal, among others. The papilla was entered in 72/74 patients (97 %). The targeted bile duct segment was reached in 62 /74 patients (84 %), with an anchoring balloon catheter needed in 21/74 (28 %). Mean investigation time was 21 minutes (15 - 27 minutes) DRC using the prototype is feasible, safe, and attains access to the bile ducts in almost all patients, with less need of an anchoring balloon catheter compared with the standard technique and short investigation and fluoroscopy times. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Radiocontrast Dye Extravasation During Sialography.

    PubMed

    Truong, Kristy; Hoffman, Henry T; Policeni, Bruno; Maley, Joan

    2018-03-01

    Evaluate the pathophysiology of contrast extravasation. Two hundred fifty-five sialograms at the University of Iowa from 2008 to 2016 were reviewed. Twelve sialograms (4.7% of total) were identified with main ductal extravasation. In each case, ductal stenosis as a diagnosis was supported by clinical history and the finding of difficulty in advancing the cannula into the duct during sialography. In all but 1 case, extravasation occurred at the distal duct with no further imaging of the ductal system. Each of the 5 cases treated with sialendoscopy with or without gland resection confirmed stenosis. Ultrasound evaluation of 5 of the cases detected ductal dilation in 4 (80%). Six of 11 computed tomography scans done before the sialogram were interpreted as normal with indirect evidence for ductal stenosis (duct dilation) reported in only 1. All extravasations were associated with either stricture alone or stricture with stone (1 case). Radiocontrast extravasation from the main duct during sialography is highly associated with the presence of ductal stricture. In our experience, the inability to fill the ductal system with radiocontrast is a useful sialographic finding that correlated closely with anatomic abnormality rather than technical error. The frequent finding of extravasation of radiocontrast supports the use of water soluble contrast.

  18. Obstructive parotitis secondary to an acute masseteric bend.

    PubMed

    Reddy, Ryan; White, David R; Gillespie, M Boyd

    2012-01-01

    To investigate 3 cases of chronic parotitis secondary to an acute bend in Stensen's duct caused by an enlargement of the masseteric space. Three female patients presented with symptoms consistent with obstructive parotitis including glandular swelling and tenderness during meals. A 10-year-old patient had unilateral facial swelling with enlargement of the masseter muscle and mandible later diagnosed as fibrous dysplasia. Salivary endoscopy showed an acute bend in Stensen's duct secondary to a mass effect. The patient's parotid swelling resolved following debulking of the mandibular mass and sialendoscopy with irrigation. Two adult patients with bilateral parotid involvement presented with bilateral masseteric hypertrophy and dental wear facets consistent with bruxism. Salivary endoscopy revealed bilateral kinking of Stensen's duct with jaw closure. Both patients improved symptomatically following nightly bite guard use and ultrasound-guided Botox injections of the masseter muscle and parotid. Obstructive parotitis is rarely caused by an acute masseteric bend. Diagnosis of a kinking Stensen's duct is aided with salivary endoscopy and imaging to determine the precipitating pathology. In the case of masseteric hypertrophy, symptomatic improvement can be achieved with Botox-induced atrophy of masseteric hypertrophy or with surgical reduction for associated fibrous dysplasia. Copyright © 2011 S. Karger AG, Basel.

  19. Static Thrust and Vectoring Performance of a Spherical Convergent Flap Nozzle with a Nonrectangular Divergent Duct

    NASA Technical Reports Server (NTRS)

    Wing, David J.

    1998-01-01

    The static internal performance of a multiaxis-thrust-vectoring, spherical convergent flap (SCF) nozzle with a non-rectangular divergent duct was obtained in the model preparation area of the Langley 16-Foot Transonic Tunnel. Duct cross sections of hexagonal and bowtie shapes were tested. Additional geometric parameters included throat area (power setting), pitch flap deflection angle, and yaw gimbal angle. Nozzle pressure ratio was varied from 2 to 12 for dry power configurations and from 2 to 6 for afterburning power configurations. Approximately a 1-percent loss in thrust efficiency from SCF nozzles with a rectangular divergent duct was incurred as a result of internal oblique shocks in the flow field. The internal oblique shocks were the result of cross flow generated by the vee-shaped geometric throat. The hexagonal and bowtie nozzles had mirror-imaged flow fields and therefore similar thrust performance. Thrust vectoring was not hampered by the three-dimensional internal geometry of the nozzles. Flow visualization indicates pitch thrust-vector angles larger than 10' may be achievable with minimal adverse effect on or a possible gain in resultant thrust efficiency as compared with the performance at a pitch thrust-vector angle of 10 deg.

  20. Differentiating Immunoglobulin G4-Related Sclerosing Cholangitis from Hilar Cholangiocarcinoma

    PubMed Central

    Tabata, Taku; Hara, Seiichi; Kuruma, Sawako; Chiba, Kazuro; Kuwata, Go; Fujiwara, Takashi; Egashira, Hideto; Koizumi, Koichi; Fujiwara, Junko; Arakawa, Takeo; Momma, Kumiko; Kurata, Masanao; Honda, Goro; Tsuruta, Koji; Itoi, Takao

    2013-01-01

    Background/Aims Few studies have differentiated immunoglobulin G (IgG) 4-related sclerosing cholangitis (IgG4-SC) from hilar cholangiocarcinoma (CC). Thus, we sought to investigate useful features for differentiating IgG4-SC from hilar CC. Methods We retrospectively compared clinical, serological, imaging, and histological features of six patients with IgG4-SC and 42 patients with hilar CC. Results In patients with hilar CC, obstructive jaundice was more frequent (p<0.01), serum total bilirubin levels were significantly higher (p<0.05), serum CA19-9 levels were significantly higher (p<0.01), and serum duke pancreatic monoclonal antigen type 2 levels were frequently elevated (p<0.05). However, in patients with IgG4-SC, the serum IgG (p<0.05) and IgG4 (p<0.01) levels were significantly higher and frequently elevated. The pancreas was enlarged in all IgG4-SC patients but only in 17% of hilar CC patients (p<0.01). Salivary and/or lacrimal gland swelling was detected in only 50% of IgG4-SC patients (p<0.01). Endoscopic retrograde cholangiography revealed that the hilar or hepatic duct was completely obstructed in 83% of hilar CC patients (p<0.01). Lower bile duct stenosis, apart from hilar bile duct stenosis, was more frequent in IgG4-SC patients (p<0.01). Bile duct wall thickening in areas without stenosis was more frequent in IgG4-SC patients (p<0.01). Conclusions An integrated diagnostic approach based on clinical, serological, imaging, and histological findings is necessary to differentiate IgG4-SC from hilar CC. PMID:23560161

  1. Morphological Evaluation of Meibomian Glands in Children and Adolescents Using Noncontact Infrared Meibography.

    PubMed

    Wu, Yuan; Li, Haili; Tang, Yun; Yan, Xiaoming

    2017-03-01

    To compare, in vivo, differences in meibomian gland morphology between children and adolescents. Sixty-nine patients were included in this study and divided into two groups: children (n = 31; age range: 3 to 11 years) and adolescents (n = 39; age range: 12 to 18 years). Images of meibomian glands were obtained by infrared meibography and analyzed using ImageJ software (developed by the National Institutes of Health; available at http://rsb.info.nih.gov/ij/download.html). Meibomian gland loss, the number of meibomian gland ducts, the relative width of the meibomian gland ducts, and the percent area of the meibomian gland acini were compared between the two groups. Meibomian gland loss was found in both groups, but the meiboscore was not significantly different between the two groups (0.35 ± 0.6 vs 0.41 ± 0.8, t = -0.314, P > .05). The number of meibomian gland ducts (25.85 ± 3.25 vs 23.23 ± 3.06, t = -3.437, P < .05), relative width of the meibomian gland ducts (69.62% ± 5% vs 66.1% ± 7%, t = -2.454, P < .05), and percent area of the meibomian gland acini (57.7% ± 4% vs 55.5% ± 4%, t = 2.571, P < .05) in the upper eyelid were significantly greater in adolescents than in children. However, no significant differences were found in the lower eyelid between the two groups. Meibography is useful for the assessment of ocular surface conditions in children and adolescents. Meibomian gland loss occurs in both children and adolescents. The meibomian glands of the upper eyelid exhibit more morphological changes in adolescents than in children. [J Pediatr Ophthalmol Strabismus. 2017;54(2):78-83.]. Copyright 2017, SLACK Incorporated.

  2. The Application of a Boundary Integral Equation Method to the Prediction of Ducted Fan Engine Noise

    NASA Technical Reports Server (NTRS)

    Dunn, M. H.; Tweed, J.; Farassat, F.

    1999-01-01

    The prediction of ducted fan engine noise using a boundary integral equation method (BIEM) is considered. Governing equations for the BIEM are based on linearized acoustics and describe the scattering of incident sound by a thin, finite-length cylindrical duct in the presence of a uniform axial inflow. A classical boundary value problem (BVP) is derived that includes an axisymmetric, locally reacting liner on the duct interior. Using potential theory, the BVP is recast as a system of hypersingular boundary integral equations with subsidiary conditions. We describe the integral equation derivation and solution procedure in detail. The development of the computationally efficient ducted fan noise prediction program TBIEM3D, which implements the BIEM, and its utility in conducting parametric noise reduction studies are discussed. Unlike prediction methods based on spinning mode eigenfunction expansions, the BIEM does not require the decomposition of the interior acoustic field into its radial and axial components which, for the liner case, avoids the solution of a difficult complex eigenvalue problem. Numerical spectral studies are presented to illustrate the nexus between the eigenfunction expansion representation and BIEM results. We demonstrate BIEM liner capability by examining radiation patterns for several cases of practical interest.

  3. Direct numerical simulation of turbulence and heat transfer in a hexagonal shaped duct

    NASA Astrophysics Data System (ADS)

    Marin, Oana; Obabko, Aleks; Schlatter, Philipp

    2014-11-01

    Flows in hexagonal shapes frequently occur in nuclear reactor applications, and are also present in honeycomb-shaped settling chambers for e.g. wind tunnels. Whereas wall-bounded turbulence has been studied comprehensively in two-dimensional channels, and to a lesser degree also in square and rectangular ducts and triangles, only very limited data for hexagonal ducts is available, including resistance correlations and mean profiles. Here, we use resolved spectral-element simulations to compute velocity and temperature in fully-developed (periodic) hexagonal duct flow. The Reynolds number, based on the fixed flow rate and the hydraulic diameter, ranges between 2000 and 20000. The temperature assumes constant wall flux or constant wall temperature. First DNS results are focused on the mean characteristics such a head loss, Nusselt number, and critical Reynolds number for sustained turbulence. Profiles, both for mean and fluctuating quantities, are extracted and discussed in the context of square ducts and pipes. Comparisons to existing experiments, RANS and empirical correlations are supplied as well. The results show a complicated and fine-scale pattern of the in-plane secondary flow, which clearly affects the momentum and temperature distribution throughout the cross section.

  4. Diagnosis of Nipple Discharge: Value of Magnetic Resonance Imaging and Ultrasonography in Comparison with Ductoscopy.

    PubMed

    Yılmaz, Ravza; Bender, Ömer; Çelik Yabul, Fatma; Dursun, Menduh; Tunacı, Mehtap; Acunas, Gülden

    2017-04-05

    Pathologic nipple discharge, which is a common reason for referral to the breast imaging service, refers to spontaneous or bloody nipple discharge that arises from a single duct. The most common cause of nipple discharge is benign breast lesions, such as solitary intraductal papilloma and papillomatosis. Nevertheless, in rare cases, a malignant cause of nipple discharge can be found. To study the diagnostic value of ultrasonography, magnetic resonance imaging, and ductoscopy in patients with pathologic nipple discharge, compare their efficacy, and investigate the importance of magnetic resonance imaging in the diagnosis of intraductal pathologies. Diagnostic accuracy study. Fifty patients with pathologic nipple discharge were evaluated by ultrasonography and magnetic resonance imaging. Of these, 44 ductoscopic investigations were made. The patients were classified according to magnetic resonance imaging, ultrasonography, and ductoscopy findings. A total of 25 patients, whose findings were reported as intraductal masses, underwent surgery oincluding endoscopic excision for two endoscopic excision. Findings were compared with the pathology results that were accepted as the gold standard in the description of the aetiology of nipple discharge. In addition, magnetic resonance imaging, ultrasonography and ductoscopy findings were analysed comparatively in patients who had no surgery. Intraductal masses were reported in 26 patients, 20 of whom operated and established accurate diagnosis of 18 patients on magnetic resonance imaging. According to the ultrasonography, intraductal masses were identified in 22 patients, 17 of whom underwent surgery. Ultrasonography established accurate diagnoses in 15 patients. Intraductal mass was identified in 22 patients and ductoscopy established accurate diagnoses based on histopathologic results in 16 patients. The sensitivities of methods were 75% in ultrasonography, 90% in magnetic resonance imaging, and 94.6% in ductoscopy. The specificities were 66.7% in ultrasonography, 66.7% in magnetic resonance imaging, and 40% in ductoscopy. Intraductal papillomas were mostly observed as oval nodules with well-circumscribed smooth margins within dilated ducts and persistant in the dynamic analysis. Lesions that protruded into the lumen of the ducts, either solitary or multiple, were characteristic ductoscopy findings of our patients who were diagnosed as having papilloma/papillomatosis. Magnetic resonance imaging and ductoscopy had no statistical superiority over each other, however they were superior to ultrasonography in the diagnosis of pathologic nipple discharge. Magnetic resonance imaging may be highly sensitive for diagnosing nipple discharge with new techniques and sequences and a non-invasive method that more advantageous for showing ductal tree visualization and is able to detect completely obstructed intraductal lesions.

  5. Peritoneal manifestations of fascioliasis on CT images: a new observation.

    PubMed

    Song, Kyoung Doo; Lim, Jae Hoon; Kim, Mi Jeong; Jang, Yun Jin; Kim, Jae Woon; Cho, Seung Hyun; Kwon, Jung Hyeok

    2013-08-01

    To describe peritoneal manifestations of fascioliasis on CT. We reviewed CT images in 31 patients with fascioliasis confirmed by enzyme-linked immunosorbent assay (ELISA) (n = 24) or surgery (n = 7). Image analyses were performed to identify hepatic, biliary, and peritoneal abnormalities. Hepatic abnormalities were seen in 28 (90.3 %) of the 31 patients. The most common finding was caves sign, which was present in 25 (80.1 %) patients. Three patients (9.7 %) presented with biliary abnormalities exhibiting dilatation and enhancing wall thickening of the bile duct, wall thickening of the gallbladder, and elongated structures in the bile duct or gallbladder. Peritoneal abnormalities were seen in 14 (45.2 %) of the 31 patients. The most common peritoneal abnormality was mesenteric or omental infiltration, which was seen in 9 (29.0 %) patients. Other peritoneal findings included lymph node enlargement (n = 7), ascites (n = 7), thickening of ligamentum teres (n = 2), and peritoneal mass (n = 2). Peritoneal manifestations of fascioliasis are relatively common, and CT findings include mesenteric or omental infiltration, lymph node enlargement, ascites, thickening of the ligamentum teres, and peritoneal masses.

  6. Novel application of simultaneous multi-image display during complex robotic abdominal procedures

    PubMed Central

    2014-01-01

    Background The surgical robot offers the potential to integrate multiple views into the surgical console screen, and for the assistant’s monitors to provide real-time views of both fields of operation. This function has the potential to increase patient safety and surgical efficiency during an operation. Herein, we present a novel application of the multi-image display system for simultaneous visualization of endoscopic views during various complex robotic gastrointestinal operations. All operations were performed using the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) with the assistance of Tilepro, multi-input display software, during employment of the intraoperative scopes. Three robotic operations, left hepatectomy with intraoperative common bile duct exploration, low anterior resection, and radical distal subtotal gastrectomy with intracorporeal gastrojejunostomy, were performed by three different surgeons at a tertiary academic medical center. Results The three complex robotic abdominal operations were successfully completed without difficulty or intraoperative complications. The use of the Tilepro to simultaneously visualize the images from the colonoscope, gastroscope, and choledochoscope made it possible to perform additional intraoperative endoscopic procedures without extra monitors or interference with the operations. Conclusion We present a novel use of the multi-input display program on the da Vinci Surgical System to facilitate the performance of intraoperative endoscopies during complex robotic operations. Our study offers another potentially beneficial application of the robotic surgery platform toward integration and simplification of combining additional procedures with complex minimally invasive operations. PMID:24628761

  7. Functional discrepancy between two liver lobes after hemilobe biliary drainage in patients with jaundice and bile duct cancer: an appraisal using (99m)Tc-GSA SPECT/CT fusion imaging.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Noda, Yoshihiro; Hata, Yasuhiro; Murata, Yoriko; Kozuki, Akihito; Tokumaru, Teppei; Nakamura, Toshio; Uka, Kiminori

    2014-11-01

    To determine the functional discrepancy between the two liver lobes using technetium 99m ((99m)Tc) diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ( GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ) single photon emission computed tomography (SPECT)/computed tomography (CT) fusion imaging following preoperative biliary drainage and portal vein embolization ( PVE portal vein embolization ) in patients with jaundice who have bile duct cancer ( BDC bile duct cancer ). This retrospective study was approved by the institutional review board, with waiver of informed consent. Preoperative (99m)Tc- GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin SPECT/CT fusion images from 32 patients with extrahepatic BDC bile duct cancer were retrospectively reviewed. Patients were classified into four groups according to the extent of biliary drainage and presence of a preoperative right PVE portal vein embolization : right lobe drainage group (right drainage), bilateral lobe drainage group (bilateral drainage), left lobe drainage group (left drainage), and left lobe drainage with right PVE portal vein embolization group (left drainage with right PVE portal vein embolization ). Percentage volume and percentage function were measured in each lobe using fusion imaging. The ratio between percentage function and percentage volume (the function-to-volume ratio) was calculated for each lobe, and the results were compared among the four groups. Statistical analysis was performed with Wilcoxon signed-rank tests and Mann-Whitney U tests. The median values for the function-to-volume ratio in the right drainage, bilateral drainage, left drainage, and left drainage with right PVE portal vein embolization group were 1.12, 1.05, 1.02, and 0.81 in the right lobe; and 0.51, 0.88, 0.96, and 1.17 in the left lobe. Significant differences in the function-to-volume ratio were observed among the four groups (right drainage vs bilateral drainage vs left drainage vs left drainage with right PVE portal vein embolization ; with P < .002, P = .023, and P < .002 for the right lobe and P < .001, P = .023, and P < .002 for the left lobe). Hepatic lobar function significantly differs between the two lobes, depending on the extent of biliary drainage and the presence of portal vein embolization.

  8. Fluid-acoustic interactions in a low area ratio supersonic jet ejector

    NASA Technical Reports Server (NTRS)

    Krothapalli, Anjaneyulu; Ross, Christopher; Yamomoto, K.; Joshi, M. C.

    1994-01-01

    An experimental investigation carried out to determine aerodynamic and acoustic characteristics of a low area ratio rectangular jet ejector is reported. A supersonic primary jet issuing from a rectangular convergent-divergent nozzle of aspect ratio 4, into a rectangular duct of area ratio 3, was used. Improved performance was found when the ejector screech tone is most intense and appears to match the most unstable Strouhal number of the free rectangular jet. When the primary jet was operating at over and ideally expanded conditions, significant noise reduction was obtained with the ejector as compared to a corresponding free jet. Application of particle image velocimetry to high speed ejector flows was demonstrated through the measurement of instantaneous two dimensional velocity fields.

  9. Theoretical design study of the MSFC wind-wheel turbine

    NASA Technical Reports Server (NTRS)

    Frost, W.; Kessel, P. A.

    1982-01-01

    A wind wheel turbine (WWT) is studied. Evaluation of the probable performance, possible practical applications, and economic viability as compared to other conventional wind energy systems is discussed. The WWT apparatus is essentially a bladed wheel which is directly exposed to the wind on the upper half and exposed to wind through multiple ducting on the lower half. The multiple ducts consist of a forward duct (front concentrator) and two side ducts (side concentrators). The forced rotation of the wheel is then converted to power through appropriate subsystems. Test results on two simple models, a paper model and a stainless steel model, are reported. Measured values of power coefficients over wind speeds ranging from 4 to 16 m/s are given. An analytical model of a four bladed wheel is also developed. Overall design features of the wind turbine are evaluated and discussed. Turbine sizing is specified for a 5 and 25 kW machine. Suggested improvements to the original design to increase performance and performance predictions for an improved WWT design are given.

  10. A new method of three-dimensional computer assisted reconstruction of the developing biliary tract.

    PubMed

    Prudhomme, M; Gaubert-Cristol, R; Jaeger, M; De Reffye, P; Godlewski, G

    1999-01-01

    A three-dimensional (3-D) computer assisted reconstruction of the biliary tract was performed in human and rat embryos at Carnegie stage 23 to describe and compare the biliary structures and to point out the anatomic relations between the structures of the hepatic pedicle. Light micrograph images from consecutive serial sagittal sections (diameter 7 mm) of one human and 16 rat embryos were directly digitalized with a CCD camera. The serial views were aligned automatically by software. The data were analysed following segmentation and thresholding, allowing automatic reconstruction. The main bile ducts ascended in the mesoderm of the hepatoduodenal ligament. The extrahepatic bile ducts: common bile duct (CD), cystic duct and gallbladder in the human, formed a compound system which could not be shown so clearly in histologic sections. The hepato-pancreatic ampulla was studied as visualised through the duodenum. The course of the CD was like a chicane. The gallbladder diameter and length were similar to those of the CD. Computer-assisted reconstruction permitted easy acquisition of the data by direct examination of the sections through the microscope. This method showed the relationships between the different structures of the hepatic pedicle and allowed estimation of the volume of the bile duct. These findings were not obvious in two-dimensional (2-D) views from histologic sections. Each embryonic stage could be rebuilt in 3-D, which could introduce the time as a fourth dimension, fundamental for the study of organogenesis.

  11. Gastroesophageal reflux demonstrated by hepatobiliary imaging in scleroderma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawaf, N.W.; Orzel, J.A.; Weiland, F.L.

    1987-03-01

    Radionuclide hepatobiliary imaging was performed on a patient with a longstanding history of scleroderma who presented with abdominal pain suggestive of biliary disease. Cystic duct patency was documented after 10 min with tracer accumulation in the second portion of the duodenum which failed to progress consistent with the duodenal hypomotility of scleroderma. The patient was given intravenous Kinevac resulting in gastroesophageal reflux of radionuclide.

  12. Progress in net shape fabrication of alpha SiC turbine components

    NASA Technical Reports Server (NTRS)

    Storm, R. S.; Naum, R. G.

    1983-01-01

    The development status of component technology in an automotive gas turbine Ceramic Applications in Turbine Engines program is discussed, with attention to such materials and processes having a low cost, net shape fabrication potential as sintered alpha-SiC that has been fashioned by means of injection molding, slip casting, and isostatic pressing. The gas turbine elements produced include a gasifier turbine rotor, a turbine wheel, a connecting duct, a combustor baffle, and a transition duct.

  13. Design and Fabrication of an Ultra-Low-Cost Turboprop for RPV/UAV applications

    DTIC Science & Technology

    1993-11-22

    Modifications were made to the engine at M-DOT to remove the existing bifurcated duct and incorporate a circular duct with V- band flange. All hardware...Due to the nature of modifications , engine cost would not be increased. If a gas-generator section based on the Sundstrand low-flow TJ-90 were to be...dangerous blade resonant frequencies existed in the design, the completed wheel was acoustically excited at various frequencies. (See Figure 7

  14. Winglet and long duct nacelle aerodynamic development for DC-10 derivatives

    NASA Technical Reports Server (NTRS)

    Taylor, A. B.

    1978-01-01

    Advanced technology for application to the Douglas DC-10 transport is discussed. Results of wind tunnel tests indicate that the winglet offers substantial cruise drag reduction with less wing root bending moment penalty than a wing-tip extension of the same effectiveness and that the long duct nacelle offers substantial drag reduction potential as a result of aerodynamic and propulsion improvements. The aerodynamic design and test of the nacelle and pylon installation are described.

  15. A generalized theory for the design of contraction cones and other low speed ducts

    NASA Technical Reports Server (NTRS)

    Barger, R. L.; Bowen, J. T.

    1972-01-01

    A generalization of the Tsien method of contraction cone design is described. The design velocity distribution is expressed in such a form that the required high order derivatives can be obtained by recursion rather than by numerical or analytic differentiation. The method is applicable to the design of diffusers and converging-diverging ducts as well as contraction cones. The computer program is described and a FORTRAN listing of the program is provided.

  16. An Unusual Necrotizing cholangiohepatitis in Broiler Chickens

    PubMed Central

    Shapiro, Janet L.; Julian, Richard J.; Hampson, Robert J.; Trenton, Ron G.; Yo, Ignatius H.

    1988-01-01

    A diagnosis of toxic necrotizing cholangiohepatitis was made in approximately 35% of a flock of 23,000 commercial broiler chickens. Affected chickens were small, and had discrete green foci throughout the liver. Seven to twelve days prior to shipping the flock to slaughter, premixes containing oxytetracycline, monensin, and 3-nitro-4-hydroxyphenylarsonic acid had been added to the ration because the birds had wet droppings and were growing slowly. The 3-nitro-4-hydroxyphenylarsonic acid had been inadvertently incorporated at ten times the recommended level. Liver and kidney of affected birds had elevated levels of total arsenic, and special strains demonstrated arsenic in necrotic foci in liver. Histologically there was marked dilation of intrahepatic bile ducts, and patchy necrosis and hyperplasia of the bile duct epithelium. Damage to bile ducts may have been a toxic manifestation of altered metabolism and excretion of the three drugs being fed to birds suffering from intercurrent diarrhea and/or undefined interactions among the drugs. ImagesFigure 1.Figure 2. PMID:17423098

  17. [Chronic recurrent parotitis].

    PubMed

    Zenk, J; Koch, M; Klintworth, N; Iro, H

    2010-03-01

    Chronic recurrent parotitis is a non-obstructive disease with episodes of mostly painful swelling of the gland. It is categorized into a juvenile and an adult form, even without clear information on its actual origin. As to the etiology of the juvenile form, genetic factors and duct malformations as well as bacterial infections are discussed. Very rarely a complete lymphatic transformation of the gland might take place. Juvenile chronic recurrent parotitis is self-limiting in about 90% of all cases, as patients grow up. The diagnosis is based on patient history and clinical findings. Sonography is the imaging method of choice. Sialendoscopy shows a typical whitish pattern of the ducts in juvenile disease. Strictures or stenoses are typical for the adult form. The therapy of choice is gland massage and sialagogues, in addition to the administration of antibiotics. In more severe cases sialendoscopy together with rinsing of the ducts and instillation of cortisone are indicated. Total parotidectomy remains the last choice and is rarely necessary.

  18. Photodynamic therapy for palliation of nonresectable bile duct cancer--preliminary results with a new diode laser system.

    PubMed

    Zoepf, T; Jakobs, R; Arnold, J C; Apel, D; Rosenbaum, A; Riemann, J F

    2001-07-01

    Preliminary results of photodynamic therapy (PDT) of bile duct cancer have shown astonishingly good results in the reduction of cholestasis, improvement of quality of life, and even prolongation of the survival time. Unfortunately, the existing dye laser systems are large and costly, and their maintenance is expensive. Therefore, we investigated the feasibility of a diode laser system for PDT of nonresectable bile duct cancer. Eight patients with nonresectable bile duct cancer were treated. Forty-eight hours after i. v. application of 2 mg/kg body weight of Photosan-3, light activation was performed by a transpapillary (four patients) or percutaneus (four patients) access. We used a cylindrical diffusor tip and illuminated using a wavelength of 633+/-3 nm and a total energy of 200 J/cm2. All patients were additionally provided with bile duct endoprostheses after PDT. Four weeks after initial PDT all patients showed a marked reduction of bile duct stenosis. The median serum bilirubin value declined from 5.8 mg/dl (2.0-10.1) to 1.0 mg/dl (0.8-4.4). The median survival time at the time of writing is 119 days (52-443). Five patients are still alive. In four patients we could change from percutaneous to transpapillary drainage after PDT, two patients showed infectious complications. PDT with the diode laser system seems to be effective in reducing malignant bile duct stenosis. This treatment is minimally invasive and has a low specific complication rate. Randomized, controlled studies comparing PDT with the insertion of endoprostheses and long term follow-up of results are needed to confirm the promising short term results.

  19. Four-step reaction for polytriazine elastomers

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.; Korus, R. A.

    1980-01-01

    Four step imidoylamidine reaction sequence is used to make crosslinked polyperfluoralkyltriazines with superior elastomeric properties, greater molecular weight, and crosslinking control. Polymers can find useful application in fuel tank sealants, o-ring, wire enamels, pneumatic ducts, and many other applications.

  20. Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could removemore » between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.« less

  1. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colon, Carlos; Martin, Eric; Parker, Danny

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWHs) on space conditioning and water heating energy use in residential applications. Two identical HPWHs, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  2. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colon, Carlos; Martin, Eric; Parker, Danny

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  3. Development of Poly(Ethylene Glycol) Hydrogels for Salivary Gland Tissue Engineering Applications

    PubMed Central

    Shubin, Andrew D.; Felong, Timothy J.; Graunke, Dean; Ovitt, Catherine E.

    2015-01-01

    More than 40,000 patients are diagnosed with head and neck cancers annually in the United States with the vast majority receiving radiation therapy. Salivary glands are irreparably damaged by radiation therapy resulting in xerostomia, which severely affects patient quality of life. Cell-based therapies have shown some promise in mouse models of radiation-induced xerostomia, but they suffer from insufficient and inconsistent gland regeneration and accompanying secretory function. To aid in the development of regenerative therapies, poly(ethylene glycol) hydrogels were investigated for the encapsulation of primary submandibular gland (SMG) cells for tissue engineering applications. Different methods of hydrogel formation and cell preparation were examined to identify cytocompatible encapsulation conditions for SMG cells. Cell viability was much higher after thiol-ene polymerizations compared with conventional methacrylate polymerizations due to reduced membrane peroxidation and intracellular reactive oxygen species formation. In addition, the formation of multicellular microspheres before encapsulation maximized cell–cell contacts and increased viability of SMG cells over 14-day culture periods. Thiol-ene hydrogel-encapsulated microspheres also promoted SMG proliferation. Lineage tracing was employed to determine the cellular composition of hydrogel-encapsulated microspheres using markers for acinar (Mist1) and duct (Keratin5) cells. Our findings indicate that both acinar and duct cell phenotypes are present throughout the 14 day culture period. However, the acinar:duct cell ratios are reduced over time, likely due to duct cell proliferation. Altogether, permissive encapsulation methods for primary SMG cells have been identified that promote cell viability, proliferation, and maintenance of differentiated salivary gland cell phenotypes, which allows for translation of this approach for salivary gland tissue engineering applications. PMID:25762214

  4. A model of the wall boundary layer for ducted propellers

    NASA Technical Reports Server (NTRS)

    Eversman, Walter; Moehring, Willi

    1987-01-01

    The objective of the present study is to include a representation of a wall boundary layer in an existing finite element model of the propeller in the wind tunnel environment. The major consideration is that the new formulation should introduce only modest alterations in the numerical model and should still be capable of producing economical predictions of the radiated acoustic field. This is accomplished by using a stepped approximation in which the velocity profile is piecewise constant in layers. In the limit of infinitesimally thin layers, the velocity profile of the stepped approximation coincides with that of the continuous profile. The approach described here could also be useful in modeling the boundary layer in other duct applications, particularly in the computation of the radiated acoustic field for sources contained in a duct.

  5. Sea-air boundary meteorological sensor

    NASA Astrophysics Data System (ADS)

    Barbosa, Jose G.

    2015-05-01

    The atmospheric environment can significantly affect radio frequency and optical propagation. In the RF spectrum refraction and ducting can degrade or enhance communications and radar coverage. Platforms in or beneath refractive boundaries can exploit the benefits or suffer the effects of the atmospheric boundary layers. Evaporative ducts and surface-base ducts are of most concern for ocean surface platforms and evaporative ducts are almost always present along the sea-air interface. The atmospheric environment also degrades electro-optical systems resolution and visibility. The atmospheric environment has been proven not to be uniform and under heterogeneous conditions substantial propagation errors may be present for large distances from homogeneous models. An accurate and portable atmospheric sensor to profile the vertical index of refraction is needed for mission planning, post analysis, and in-situ performance assessment. The meteorological instrument used in conjunction with a radio frequency and electro-optical propagation prediction tactical decision aid tool would give military platforms, in real time, the ability to make assessments on communication systems propagation ranges, radar detection and vulnerability ranges, satellite communications vulnerability, laser range finder performance, and imaging system performance predictions. Raman lidar has been shown to be capable of measuring the required atmospheric parameters needed to profile the atmospheric environment. The atmospheric profile could then be used as input to a tactical decision aid tool to make propagation predictions.

  6. Numerical investigation of Al2O3/water nanofluid laminar convective heat transfer through triangular ducts

    NASA Astrophysics Data System (ADS)

    Zeinali Heris, Saeed; Noie, Seyyed Hossein; Talaii, Elham; Sargolzaei, Javad

    2011-12-01

    In this article, laminar flow-forced convective heat transfer of Al2O3/water nanofluid in a triangular duct under constant wall temperature condition is investigated numerically. In this investigation, the effects of parameters, such as nanoparticles diameter, concentration, and Reynolds number on the enhancement of nanofluids heat transfer is studied. Besides, the comparison between nanofluid and pure fluid heat transfer is achieved in this article. Sometimes, because of pressure drop limitations, the need for non-circular ducts arises in many heat transfer applications. The low heat transfer rate of non-circular ducts is one the limitations of these systems, and utilization of nanofluid instead of pure fluid because of its potential to increase heat transfer of system can compensate this problem. In this article, for considering the presence of nanoparticl: es, the dispersion model is used. Numerical results represent an enhancement of heat transfer of fluid associated with changing to the suspension of nanometer-sized particles in the triangular duct. The results of the present model indicate that the nanofluid Nusselt number increases with increasing concentration of nanoparticles and decreasing diameter. Also, the enhancement of the fluid heat transfer becomes better at high Re in laminar flow with the addition of nanoparticles.

  7. Congenital cystic lesions of the head and neck.

    PubMed

    Ibrahim, Mohannad; Hammoud, Khaled; Maheshwari, Mohit; Pandya, Amit

    2011-08-01

    This article presents clinical characteristics and radiologic features of congenital cervical cystic masses, among them thyroglossal duct cysts, cystic hygromas, branchial cleft cysts, and the some of the rare congenital cysts, such as thymic and cervical bronchogenic cysts. The imaging options and the value of each for particular masses, as well as present clinical and radiologic images for each, are discussed. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Mesospheric front observations by the OH airglow imager carried out at Ferraz Station on King George Island, Antarctic Peninsula, in 2011

    NASA Astrophysics Data System (ADS)

    Giongo, Gabriel Augusto; Valentin Bageston, José; Prado Batista, Paulo; Wrasse, Cristiano Max; Dornelles Bittencourt, Gabriela; Paulino, Igo; Paes Leme, Neusa Maria; Fritts, David C.; Janches, Diego; Hocking, Wayne; Schuch, Nelson Jorge

    2018-02-01

    The main goals of this work are to characterize and investigate the potential wave sources of four mesospheric fronts identified in the hydroxyl near-infrared (OH-NIR) airglow images, obtained with an all-sky airglow imager installed at Comandante Ferraz Antarctic Station (EACF, as per its Portuguese acronym) located on King George Island in the Antarctic Peninsula. We identified and analyzed four mesospheric fronts in 2011 over King George Island. In addition, we investigate the atmospheric background environment between 80 and 100 km altitude and discuss the ducts and propagation conditions for these waves. For that, we used wind data obtained from a meteor radar operated at EACF and temperature data obtained from the TIMED/SABER satellite. The vertical wavenumber squared, m2, was calculated for each of the four waves. Even though no clearly defined duct (indicated by positive values of m2 sandwiched between layers above and below with m2 < 0) was found in any of the events, favorable propagation conditions for horizontal propagation of the fronts were found in three cases. In the fourth case, the wave front did not find any duct support and it appeared to dissipate near the zenith, transferring energy and momentum to the medium and, consequently, accelerating the wind in the wave propagation direction (near to south) above the OH peak (88-92 km). The likely wave sources for these four cases were investigated by using meteorological satellite images and in two cases we could find that strong instabilities were potential sources, i.e., a cyclonic activity and a large convective cloud cell. In the other two cases it was not possible to associate troposphere sources as potential candidates for the generation of such wave fronts observed in the mesosphere and secondary wave sources were attributed to these cases.

  9. Pancreatic Duct in Autoimmune Pancreatitis: Intraindividual Comparison of Magnetic Resonance Pancreatography at 1.5 T and 3.0 T.

    PubMed

    Kim, Jin Hee; Byun, Jae Ho; Kim, Myung-Hwan; Lee, Sung Koo; Kim, Song Cheol; Kim, Hyoung Jung; Lee, Seung Soo; Kim, So Yeon; Lee, Moon-Gyu

    2017-08-01

    The aim of this study was to intraindividually compare magnetic resonance pancreatography (MRP) image quality at 1.5 T and 3.0 T when demonstrating main pancreatic duct (MPD) abnormalities in patients with autoimmune pancreatitis (AIP). Thirty prospectively enrolled patients with AIP underwent MRP at both 1.5 T and 3.0 T followed by endoscopic retrograde pancreatography before treatment. Two readers independently analyzed the MRP images and graded the visualization of MPD strictures and full-length MPD, using endoscopic retrograde pancreatography as the reference standard, as well as overall image artifacts on a 4-point scale. The contrast between the MPD and periductal area was calculated using a region-of-interest measurement. Visualization scores of MPD strictures and full-length MPD, and summed scores of each qualitative analysis, were significantly greater at 3.0-T MRP than at 1.5-T MRP for both readers (P ≤ 0.02). There were less image artifacts at 3.0 T compared with 1.5 T (P ≤ 0.052). The contrast between the MPD and periductal area was significantly greater at 3.0-T MRP than at 1.5-T MRP (P < 0.001). The MRP at 3.0 T was superior to 1.5-T MRP for demonstrating MPD abnormalities in AIP, with better image contrast and fewer image artifacts. Consequently, 3.0-T MRP may be useful for the diagnosis and management of patients with AIP.

  10. Design and Testing of Non-Toxic RCS Thrusters for Second Generation Reusable Launch Vehicle

    NASA Technical Reports Server (NTRS)

    Calvignac, Jacky; Dang, Lisa; Tramel, Terri; Paseur, Lila; Champion, Robert (Technical Monitor)

    2003-01-01

    Under NASA sponsorship, Northrop Grumman Space Technology (NGST) designed, built and tested two non-toxic, reaction control engines, one using liquid oxygen (LOX) and liquid hydrogen (LH2) and the other using liquid oxygen and ethanol. This paper presents the design and testing of the LOX/LH2 thruster. The two key enabling technologies are the coaxial liquid-on-liquid pintle injector and the fuelcooling duct. The workhorse thruster was hotfire tested at the NASA Marshall Space Flight Center Test Stand 500 in March and April of 2002. All tests were performed at sea-level conditions. During the test program, 7 configurations were tested, including 2 combustion chambers, 3 LOX injector pintle tips, and 4 LHp injector settings. The operating conditions surveyed were 70 to 100% thrust levels, mixture ratios from 3.27 to 4.29, and LH2 duct cooling from 18.0 to 25.5% fuel flow. The copper heat sink chamber was used for 16 burns, each burn lasting from 0.4 to 10 seconds, totaling 51.4 seconds, followed by Haynes chamber testing ranging from 0.9 to 120 seconds, totaling 300.9 seconds. The performance of the engine reached 95% C* efficiency. The temperature on the Haynes chamber remained well below established material limits, with the exception of one localized hot spot. These results demonstrate that both the coaxial liquid-on-liquid pintle injector design and fuel duct concepts are viable for the intended application. The thruster headend design maintained cryogenic injection temperatures while firing, which validates the selected injector design approach for minimal heat soak-back. Also, off -nominal operation without adversely impacting the thermal response of the engine showed the robustness of the duct design, a key design feature for this application. By injecting fuel into the duct, the throat temperatures are manageable, yet the split of fuel through the cooling duct does not compromise the overall combstion efficiency, which indicates that, provided proper design refinement, such a concept could be applied to a high-performance version of the thruster.

  11. [Unicornuate uterus with cavitary non-communicating rudimentary horn: magnetic resonance characterization].

    PubMed

    Chamorro-Oscullo, Jenny Del Rocío; Sánchez-Cortázar, Julián Antonio; Gómez-Pérez, María de Guadalupe

    2018-01-01

    Mullerian duct or paramesonephric anomalies are a group of congenital malformations of the female genital tract that result from the alteration in one or more stages of embryonic development. The prevalence has increased, probably due to the progress of diagnostic imaging methods and the relevance that it has acquired in young women with infertility problems. Magnetic resonance imaging (MRI) is currently the method of choice for characterizing the different types of Mullerian anomalies, its complications and associated pathology. Unicornuate uterus correspond to class II of classification of Mullerian duct anomalies developed by the American Society for Reproductive Medicine. According to this, four subtypes have been identified, each with different clinical implications. A cavitated, non-communicating rudimentary horn in a unicornuate uterus is associated with an increased incidence of gynecological problems and obstetric complications that sometimes threaten the lives of patients, reason why its suspicion, diagnosis and treatment is necessary. We report the case of a patient with infertility in which this subtype of congenital malformation was discovered.

  12. What is the role of endoscopic retrograde cholangiopancreatography in assessing traumatic rupture of the pancreatic in children?

    PubMed

    Keil, Radan; Drabek, Jiri; Lochmannova, Jindra; Stovicek, Jan; Rygl, Michal; Snajdauf, Jiri; Hlava, Stepan

    2016-01-01

    Trauma is one of the most common causes of morbidity and mortality in the pediatric population. The diagnosis of pancreatic injury is based on clinical presentation, laboratory and imaging findings, and endoscopic methods. CT scanning is considered the gold standard for diagnosing pancreatic trauma in children. This retrospective study evaluates data from 25 pediatric patients admitted to the University Hospital Motol, Prague, with blunt pancreatic trauma between January 1999 and June 2013. The exact grade of injury was determined by CT scans in 11 patients (47.8%). All 25 children underwent endoscopic retrograde cholangiopancreatography (ERCP). Distal pancreatic duct injury (grade III) was found in 13 patients (52%). Proximal pancreatic duct injury (grade IV) was found in four patients (16 %). Major contusion without duct injury (grade IIB) was found in six patients (24%). One patient experienced duodeno-gastric abruption not diagnosed on the CT scan. The diagnosis was made endoscopically during ERCP. Grade IIB pancreatic injury was found in this patient. One patient (4%) with pancreatic pseudocyst had a major contusion of pancreas without duct injury (grade IIA). Four patients (16%) with grade IIB, III and IV pancreatic injury were treated exclusively and nonoperatively with a pancreatic stent insertion and somatostatine. Two patients (8%) with a grade IIB injury were treated conservatively only with somatostatine without drainage. Eighteen (72 %) children underwent surgical intervention within 24 h after ERCP. ERCP is helpful when there is suspicion of pancreatic duct injury in order to exclude ductal leakage and the possibility of therapeutic intervention. ERCP can speed up diagnosis of higher grade of pancreatic injuries.

  13. Subareolar breast abscess in male patients: a report of two patients with a literature review.

    PubMed

    Kazama, Takashi; Tabei, Isao; Sekine, Chikako; Funamizu, Naotake; Onda, Shinji; Okamoto, Tomoyoshi; Takeyama, Hiroshi; Morikawa, Toshiaki

    2017-12-19

    Subareolar breast abscess (SBA) is a rare infectious disease of the breast in male patients. Herein, we report two male patients with SBA. Patient 1 was initially diagnosed with a malignant tumor based on imaging findings; ultrasonography revealed a hypoechoic mass with blood flow. Patient 2 was diagnosed with inflammatory changes to his nipple; ultrasonography findings supported the diagnosis with an irregular hypoechoic mass with blood flow. Both patients received a cytological or histological biopsy preoperatively, which showed an abscess without malignant cells. These cases serve as an important reminder to consider complete resection of the tumor including the responsible mammary duct (tumor and duct resection (TDR)) for curative therapy of SBA.

  14. [A new case of a rare anomaly of the biliary tract].

    PubMed

    Orea-Martínez, J G; Bretón-Márquez, J H; Contreras-Vera, R A; Anestesiólogo Práctica Privada, M

    2011-01-01

    We present a 36 year-old female with jaundice, who underwent surgical exploration with the diagnosis of probable biliary fasciolosis vs. Mirizzi´s syndrome. At surgery we found a short common duct leading to the body of gallbladder followed by a long cystic duct draining into the duodenum. Patient underwent hepaticojejunostomy with a Roux Y. The suspicious images of fasciola corresponded to inflammatory nodes in the hepatic hilium. A literature review was conducted and we found very few cases with this rare anomaly, some of them were managed with preservation of a portion of the gallbladder. We discuss the possible implications of this treatment and present an alternative management.

  15. Clinical application of indocyanine green-fluorescence imaging during hepatectomy

    PubMed Central

    Ishizawa, Takeaki; Saiura, Akio

    2016-01-01

    In hepatobiliary surgery, the fluorescence and bile excretion of indocyanine green (ICG) can be used for real-time visualization of biological structure. Fluorescence cholangiography is used to obtain fluorescence images of the bile ducts following intrabiliary injection of 0.025−0.5 mg/mL ICG or intravenous injection of 2.5 mg ICG. Recently, the latter technique has been used in laparoscopic/robotic cholecystectomy. Intraoperative fluorescence imaging can be used to identify subcapsular hepatic tumors. Primary and secondary hepatic malignancy can be identified by intraoperative fluorescence imaging using preoperative intravenous injection of ICG through biliary excretion disorders that exist in cancerous tissues of hepatocellular carcinoma (HCC) and in non-cancerous hepatic parenchyma around adenocarcinoma foci. Intraoperative fluorescence imaging may help detect tumors to be removed, especially during laparoscopic hepatectomy, in which visual inspection and palpation are limited, compared with open surgery. Fluorescence imaging can also be used to identify hepatic segments. Boundaries of hepatic segments can be visualized following injection of 0.25−2.5 mg/mL ICG into the portal veins or by intravenous injection of 2.5 mg ICG following closure of the proximal portal pedicle toward hepatic regions to be removed. These techniques enable identification of hepatic segments before hepatectomy and during parenchymal transection for anatomic resection. Advances in imaging systems will increase the use of fluorescence imaging as an intraoperative navigation tool that can enhance the safety and accuracy of open and laparoscopic/robotic hepatobiliary surgery. PMID:27500144

  16. Progress on Variable Cycle Engines

    NASA Technical Reports Server (NTRS)

    Westmoreland, J. S.; Howlett, R. A.; Lohmann, R. P.

    1979-01-01

    Progress in the development and future requirements of the Variable Stream Control Engine (VSCE) are presented. The two most critical components of this advanced system for future supersonic transports, the high performance duct burner for thrust augmentation, and the low jet coannular nozzle were studied. Nozzle model tests substantiated the jet noise benefit associated with the unique velocity profile possible with a coannular nozzle system on a VSCE. Additional nozzle model performance tests have established high thrust efficiency levels only at takeoff and supersonic cruise for this nozzle system. An experimental program involving both isolated component and complete engine tests has been conducted for the high performance, low emissions duct burner with good results and large scale testing of these two components is being conducted using a F100 engine as the testbed for simulating the VSCE. Future work includes application of computer programs for supersonic flow fields to coannular nozzle geometries, further experimental testing with the duct burner segment rig, and the use of the Variable Cycle Engine (VCE) Testbed Program for evaluating the VSCE duct burner and coannular nozzle technologies.

  17. The effect of wall geometry in particle-laden turbulent flow

    NASA Astrophysics Data System (ADS)

    Abdehkakha, Hoora; Iaccarino, Gianluca

    2016-11-01

    Particle-laden turbulent flow plays a significant role in various industrial applications, as turbulence alters the exchange of momentum and energy between particles and fluid flow. In wall-bounded flows, inhomogeneity in turbulent properties is the primary cause of turbophoresis that leads the particles toward the walls. Conversely, shear-induced lift force on the particles can become important if large scale vortical structures are present. The objective of this study is to understand the effects of geometry on fluid flows and consequently on particles transport and concentration. Direct numerical simulations combined with point particle Lagrangian tracking are performed for several geometries such as a pipe, channel, square duct, and squircle (rounded-corners duct). In non-circular ducts, anisotropic and inhomogeneous Reynolds stresses are the most influential phenomena that produce the secondary flows. It has been shown that these motions can have a significant impact on transporting momentum, vorticity, and energy from the core of the duct to the corners. The main focus of the present study is to explore the effects of near the wall structures and secondary flows on turbophoresis, lift, and particle concentration.

  18. [Gastric adenomyoma clinically simulating hypertrophic pyloric stenosis].

    PubMed

    Sánchez García, S; Rubio Solís, D; Anes González, G; González Sánchez, S

    2016-01-01

    Gastric adenomyomas are extremely uncommon benign tumors in children. On histologic examination, these tumors have an epithelial component similar to pancreatic ducts. We present a case of a pyloric adenomyoma that clinically simulated hypertrophic pyloric stenosis in a newborn girl. Imaging tests, fundamentally magnetic resonance imaging, were very important in the characterization and diagnosis of this entity. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  19. Large Eddy Simulation of turbulence induced secondary flows in stationary and rotating straight square ducts

    NASA Astrophysics Data System (ADS)

    Sudjai, W.; Juntasaro, V.; Juttijudata, V.

    2018-01-01

    The accuracy of predicting turbulence induced secondary flows is crucially important in many industrial applications such as turbine blade internal cooling passages in a gas turbine and fuel rod bundles in a nuclear reactor. A straight square duct is popularly used to reveal the characteristic of turbulence induced secondary flows which consists of two counter rotating vortices distributed in each corner of the duct. For a rotating duct, the flow can be divided into the pressure side and the suction side. The turbulence induced secondary flows are converted to the Coriolis force driven two large circulations with a pair of additional vortices on the pressure wall due to the rotational effect. In this paper, the Large Eddy Simulation (LES) of turbulence induced secondary flows in a straight square duct is performed using the ANSYS FLUENT CFD software. A dynamic kinetic energy subgrid-scale model is used to describe the three-dimensional incompressible turbulent flows in the stationary and the rotating straight square ducts. The Reynolds number based on the friction velocity and the hydraulic diameter is 300 with the various rotation numbers for the rotating cases. The flow is assumed fully developed by imposing the constant pressure gradient in the streamwise direction. For the rotating cases, the rotational axis is placed perpendicular to the streamwise direction. The simulation results on the secondary flows and the turbulent statistics are found to be in good agreement with the available Direct Numerical Simulation (DNS) data. Finally, the details of the Coriolis effects are discussed.

  20. Surgical Anatomy of the Left Lateral Segment as Applied to Living-Donor and Split-Liver Transplantation

    PubMed Central

    Reichert, Paulo R.; Renz, John F.; D’Albuquerque, Luiz A. C.; Rosenthal, Philip; Lim, Robert C.; Roberts, John P.; Ascher, Nancy L.; Emond, Jean C.

    2000-01-01

    Objective To evaluate intrahepatic vascular and biliary anatomy of the left lateral segment (LLS) as applied to living-donor and split-liver transplantation. Summary Background Data Living-donor and split-liver transplantation are innovative surgical techniques that have expanded the donor pool. Fundamental to the application of these techniques is an understanding of intrahepatic vascular and biliary anatomy. Methods Pathologic data obtained from cadaveric liver corrosion casts and liver dissections were clinically correlated with the anatomical findings obtained during split-liver, living-donor, and reduced-liver transplants. Results The anatomical relation of the left bile duct system with respect to the left portal venous system was constant, with the left bile duct superior to the extrahepatic transverse portion of the left portal vein. Four specific patterns of left biliary anatomy and three patterns of left hepatic venous drainage were identified and described. Conclusions Although highly variable, the biliary and hepatic venous anatomy of the LLS can be broadly categorized into distinct patterns. The identification of the LLS duct origin lateral to the umbilical fissure in segment 4 in 50% of cast specimens is significant in the performance of split-liver and living-donor transplantation, because dissection of the graft pedicle at the level of the round ligament will result in separate ducts from segments 2 and 3 in most patients, with the further possibility of an anterior segment 4 duct. A connective tissue bile duct plate, which can be clinically identified, is described to guide dissection of the segment 2 and 3 biliary radicles. PMID:11066137

  1. Heat Transfer Enhancement for Finned-tube Heat Exchangers with Winglets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, James Edward; Sohal, Manohar Singh

    2000-11-01

    This paper presents the results of an experimental study of forced convection heat transfer in a narrow rectangular duct fitted with a circular tube and/or a delta-winglet pair. The duct was designed to simulate a single passage in a fin-tube heat exchanger. Heat transfer measurements were obtained using a transient technique in which a heated airflow is suddenly introduced to the test section. High-resolution local fin-surface temperature distributions were obtained at several times after initiation of the transient using an imaging infrared camera. Corresponding local fin-surface heat transfer coefficient distributions were then calculated from a locally applied one-dimensional semi-infinite inversemore » heat conduction model. Heat transfer results were obtained over an airflow rate ranging from 1.51 x 10-3 to 14.0 x 10-3 kg/s. These flow rates correspond to a duct-height Reynolds number range of 670 – 6300 with a duct height of 1.106 cm and a duct width-toheight ratio, W/H, of 11.25. The test cylinder was sized such that the diameter-to-duct height ratio, D/H is 5. Results presented in this paper reveal visual and quantitative details of local fin-surface heat transfer distributions in the vicinity of a circular tube, a delta-winglet pair, and a combination of a circular tube and a delta-winglet pair. Comparisons of local and average heat transfer distributions for the circular tube with and without winglets are provided. Overall mean finsurface Nusselt-number results indicate a significant level of heat transfer enhancement associated with the deployment of the winglets with the circular cylinder. At the lowest Reynolds numbers (which correspond to the laminar operating conditions of existing geothermal air-cooled condensers), the enhancement level is nearly a factor of two. At higher Reynolds numbers, the enhancement level is close to 50%.« less

  2. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    PubMed Central

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  3. Prenatal and accurate perinatal diagnosis of type 2 H or ductular duplicate gallbladder.

    PubMed

    Maggi, Umberto; Farris, Giorgio; Carnevali, Alessandra; Borzani, Irene; Clerici, Paola; Agosti, Massimo; Rossi, Giorgio; Leva, Ernesto

    2018-02-07

    Double gallbladder is a rare biliary anomaly. Perinatal diagnosis of the disorder has been reported in only 6 cases, and in 5 of them the diagnosis was based on ultrasound imaging only. However, the ultrasound technique alone does not provide a sufficiently precise description of cystic ducts and biliary anatomy, an information that is crucial for a correct classification and for a possible future surgery. At 21 weeks of gestational age of an uneventful pregnancy in a 38 year old primipara mother, a routine ultrasound screening detected a biliary anomaly in the fetus suggestive of a double gallbladder. A neonatal abdominal ultrasonography performed on postnatal day 2 confirmed the diagnosis. On day 12 the newborn underwent a Magnetic Resonance Cholangiopancreatography (MRCP) that clearly characterized the anatomy of the anomaly: both gallbladders had their own cystic duct and both had a separate insertion in the main biliary duct. We report a case of early prenatal suspected duplicate gallbladder that was confirmed by a neonatal precise diagnosis of a Type 2, H or ductular duplicate gallbladder, using for the first time 3D images of Magnetic resonance cholangiopancreatography in a newborn. An accurate anatomical diagnosis is mandatory in patients undergoing a possible future cholecystectomy, to avoid surgical complications or reoperations. Therefore, in case of a perinatal suspicion of a double gallbladder, neonates should undergo a Magnetic resonance cholangiopancreatography. A review of the Literature about this variant is included.

  4. Chronic parotitis with multiple calcifications: Clinical and sialendoscopic findings.

    PubMed

    Jáuregui, Emmanuel; Kiringoda, Ruwan; Ryan, William R; Eisele, David W; Chang, Jolie L

    2017-07-01

    To characterize clinical, imaging, and sialendoscopy findings in patients with chronic parotitis and multiple parotid calcifications. Retrospective review. Clinical history, radiographic images and reports, lab tests, and operative reports were reviewed for adult patients with chronic parotitis and multiple parotid calcifications who underwent parotid sialendoscopy. Thirteen of 133 (10%) patients undergoing parotid sialendoscopy for chronic sialadenitis had more than one calcification in the region of the parotid gland. Seven patients (54%) were diagnosed with immune-mediated disease from autoimmune parotitis (positive Sjögren's antibodies or antinuclear antibodies) or human immunodeficiency virus (HIV) disease. The six patients (46%) who did not have an immune-mediated disorder had most calcifications located anterior or along the masseter muscle. Eight of 13 patients (61%) had at least one calculus found in the parotid duct on sialendoscopy. Four patients (38%) had multiple punctate calcifications within the parotid gland, all of whom had either autoimmune parotitis or HIV. None of the proximal or punctate parotid calcifications posterior to the masseter were visualized on sialendoscopy. Chronic parotitis in conjunction with multiple parotid calcifications is uncommon and was identified in 10% of our cohort. We contrast two classifications of parotid calcifications: 1) intraductal stones that cause recurrent duct obstruction and are often located within the main parotid duct along or anterior to the masseter and 2) punctate intraparenchymal parotid gland calcifications that are not visualized on sialendoscopy and may represent underlying inflammatory disease. 4 Laryngoscope, 127:1565-1570, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Holographic flow visualization in rotating turbomachinery

    NASA Astrophysics Data System (ADS)

    Parker, R. J.; Reeves, M.

    1990-11-01

    Holographic flow visualization has found many applications in rotating turbomachinery. Applications in the design of aeroengine fans, automotive turbochargers, turbines, helicopter rotors, and advanced propfans are discussed. Work in ducted rotating flows and rotating free aerofoils is brought together and new developments in each field are revealed.

  6. Advanced Metallic Seal for High Temperature Applications

    NASA Technical Reports Server (NTRS)

    Nolan, Terence; Swensen, Jeff; Layer, Jeff

    2006-01-01

    The U-Plex(Registered TradeMark) was designed to allow greater elastic deflection capability in a given gland volume than the now conventional E-seal(Regitered TradeMark). Greater deflection capability with the associated lower bending stresses provides several benefits. For pneumatic duct joints, the axial free height is increased to allow sealing of flanges with weld distortions significantly in excess of what could be tolerated with E-seals(Registered TradeMark), This performance is achieved while maintaining the reusability and ease of assembly typical of E-seal(Registered TradeMark) rigid duct joints.

  7. Building America Case Study: Effect of Ducted HPWH on Space Conditioning and Water Heating Energy Use - Central Florida Lab Home, Cocoa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-04-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  8. Applications of nuclear magnetic resonance in paediatric surgery: magnetic resonance cholangiopancreatography and new sequences.

    PubMed

    Ragazzi, S; Vanzulli, A; Del Maschio, A; Tomaselli, V; Dell' Agnola, C A

    2007-12-01

    The aim of the study was to evaluate fast magnetic resonance cholangio-pancreatography (MRCP) sequences as an alternative and safe investigation method for neonatal and children's pancreaticobiliary diseases. Between January 2000 and December 2000, five children (age: 1 month 14 years; mean: 7 years) affected by pancreaticobiliary diseases or already operated for biliary pathologies were studied. Patients were evaluated by 1.5 T magnet single shot T2-weighted sequences (1 image per s, TR = infinite, TE = 150-180 ms). T1-weighted conventional sequences were obtained to study parenchymal tissue. No patient needed general anaesthetic. Only in one case was sedation necessary. Fast MRCP sequences provided very precise information on biliary tract anatomy. They revealed the intra and extrahepatic bile ducts, the gallbladder, the common bile duct and the bilio-pancreatic junction in all cases investigated. MRCP allowed us to evaluate Roux-en-Y type bilio-enteric anastomosis as accurately as percutaneous transhepatic cholangiography (PTC). In addition MRCP was the only reliable study in evaluating Roux-en-Y type anastomosis where ultrasonography (US) and endoscopic retrograde cholangiography (ERCP) could not be used. In conclusion MRCP is an accurate and non-invasive method with which to investigate the anatomy of the pancreaticobiliary tract in children. It could become the investigation of choice after US in the case of biliary and pancreatic diseases.

  9. Gender identification of shovelnose sturgeon using ultrasonic and endoscopic imagery and the application of the method to the pallid sturgeon

    USGS Publications Warehouse

    Wildhaber, M.L.; Papoulias, D.M.; DeLonay, A.J.; Tillitt, D.E.; Bryan, J.L.; Annis, M.L.; Allert, J.A.

    2005-01-01

    Monthly sampling of shovelnose sturgeon Scaphirhynchus platorynchus, a biological surrogate for the endangered pallid sturgeon Scaphirhynchus albus, was conducted to develop a multiseasonal profile of reproductive stages. Data collected included histological characteristics of gonads from wild caught fish and laboratory and field ultrasonic and endoscopic images. These data were used to compare effectiveness of ultrasonic and endoscopic techniques at identifying gender of adult shovelnose sturgeon at different reproductive stages. The least invasive method (i.e. ultrasound) was least effective while the most invasive (i.e. endoscope through an abdominal incision) was the most effective at identifying shovelnose sturgeon gender. In most cases, success rate for identifying males was greater than females, with success at identifying both genders greater in more advanced reproductive stages. Concomitantly, for most months average reproductive stage was more advanced for males than females. April and May were the months with the most advanced reproductive stage, and were the months when ultrasound was most effective. Methods were also applied in the Upper Missouri River to validate their use on pallid sturgeon Scaphirhynchus albus. Ultrasound was successful at identifying pallid sturgeon gender, however, endoscopic examination through the urogenital duct was only successful at identifying pallid sturgeon gender when the urogenital duct was not opaque. ?? 2005 The Fisheries Society of the British Isles.

  10. Field Test of Advanced Duct-Sealing Technologies Within the Weatherization Assistance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ternes, MP

    A field test of an aerosol-spray duct-sealing technology and a conventional, best-practice approach was performed in 80 homes to determine the efficacy and programmatic needs of the duct-sealing technologies as applied in the U.S. Department of Energy Weatherization Assistance Program. The field test was performed in five states: Iowa, Virginia, Washington, West Virginia, and Wyoming. The study found that, compared with the best-practice approach, the aerosol-spray technology is 50% more effective at sealing duct leaks and can potentially reduce labor time and costs for duct sealing by 70%, or almost 4 crew-hours. Further study to encourage and promote use ofmore » the aerosol-spray technology within the Weatherization Assistance Program is recommended. A pilot test of full production weatherization programs using the aerosol-spray technology is recommended to develop approaches for integrating this technology with other energy conservation measures and minimizing impacts on weatherization agency logistics. In order to allow or improve adoption of the aerosol spray technology within the Weatherization Assistance Program, issues must be addressed concerning equipment costs, use of the technology under franchise arrangements with Aeroseal, Inc. (the holders of an exclusive license to use this technology), software used to control the equipment, safety, and training. Application testing of the aerosol-spray technology in mobile homes is also recommended.« less

  11. Melatonin attenuates oxidative stress, liver damage and hepatocyte apoptosis after bile-duct ligation in rats.

    PubMed

    Aktas, Cevat; Kanter, Mehmet; Erboga, Mustafa; Mete, Rafet; Oran, Mustafa

    2014-10-01

    The goal of this study was to evaluate the possible protective effects of melatonin against cholestatic oxidative stress, liver damage and hepatocyte apoptosis in the common rats with bile duct ligation (BDL). A total of 24 male Wistar albino rats were divided into three groups: control, BDL and BDL + received melatonin; each group contains eight animals. Melatonin-treated BDL rats received daily melatonin 100 mg/kg/day via intraperitoneal injection. The application of BDL clearly increased the malondialdehyde (MDA) levels and decreased the superoxide dismutase (SOD) and glutathione (GSH) activities. Melatonin treatment significantly decreased the elevated tissue MDA levels and increased the reduced SOD and GSH enzyme levels in the tissues. The changes demonstrate that the bile duct proliferation and fibrosis in expanded portal tracts include the extension of proliferated bile ducts into lobules, mononuclear cells and neutrophil infiltration into the widened portal areas as observed in the BDL group. The data indicate that melatonin attenuates BDL-induced cholestatic liver injury, bile duct proliferation and fibrosis. The α-smooth muscle actin (α-SMA) and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL)-positive cells in the BDL were observed to be reduced with the melatonin treatment. These results suggest that administration of melatonin is a potentially beneficial agent to reduce liver damage in BDL by decreasing oxidative stress. © The Author(s) 2012.

  12. Development of a 32 Inch Diameter Levitated Ducted Fan Conceptual Design

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.; Gallo, Christopher a.; Solano, Paul A.; Thompson, William K.; Vrnak, Daniel R.

    2006-01-01

    The NASA John H. Glenn Research Center has developed a revolutionary 32 in. diameter Levitated Ducted Fan (LDF) conceptual design. The objective of this work is to develop a viable non-contact propulsion system utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels, and mitigate many of the concerns and limitations encountered in conventional aircraft propulsors. The physical layout consists of a ducted fan drum rotor with blades attached at the outer diameter and supported by a stress tuner ring at the inner diameter. The rotor is contained within a stator. This concept exploits the unique physical dimensions and large available surface area to optimize a custom, integrated, electromagnetic system that provides both the levitation and propulsion functions. The rotor is driven by modulated electromagnetic fields between the rotor and the stator. When set in motion, the time varying magnetic fields interact with passive coils in the stator assembly to produce repulsive forces between the stator and the rotor providing magnetic suspension. LDF can provide significant improvements in aviation efficiency, reliability, and safety, and has potential application in ultra-efficient motors, computers, and space power systems.

  13. Flow regimes of adiabatic gas-liquid two-phase under rolling conditions

    NASA Astrophysics Data System (ADS)

    Yan, Chaoxing; Yan, Changqi; Sun, Licheng; Xing, Dianchuan; Wang, Yang; Tian, Daogui

    2013-07-01

    Characteristics of adiabatic air/water two-phase flow regimes under vertical and rolling motion conditions were investigated experimentally. Test sections are two rectangular ducts with the gaps of 1.41 and 10 mm, respectively, and a circular tube with 25 mm diameter. Flow regimes were recorded by a high speed CCD-camera and were identified by examining the video images. The experimental results indicate that the characteristics of flow patterns in 10 mm wide rectangular duct under vertical condition are very similar to those in circular tube, but different from the 1.41 mm wide rectangular duct. Channel size has a significant influence on flow pattern transition, boundary of which in rectangular channels tends asymptotically towards that in the circular tube with increasing the width of narrow side. Flow patterns in rolling channels are similar to each other, nevertheless, the effect of rolling motion on flow pattern transition are significantly various. Due to the remarkable influences of the friction shear stress and surface tension in the narrow gap duct, detailed flow pattern maps of which under vertical and rolling conditions are indistinguishable. While for the circular tube with 25 mm diameter, the transition from bubbly to slug flow occurs at a higher superficial liquid velocity and the churn flow covers more area on the flow regime map as the rolling period decreases.

  14. The era of ultrasonography during laparoscopic cholecystectomy.

    PubMed

    Onders, Raymond P; Hallowell, Peter T

    2005-03-01

    The use of ultrasound cholangiography during cholecystectomy has been well described. This study was undertaken to assess the use of the umbilical port exclusively for ultrasound and to assess its employment on the use of fluoroscopy resources. In addition, we also looked at the increased use of ultrasound from 2000 to 2004. The use of imaging techniques during all cholecystectomies was analyzed from January 2000 to July 2001 for one surgeon and compared with that surgeon's present use from January 2004 to June 2004. Patient demographics, intraoperative finding, and postoperative results were reviewed. During the first study period, ultrasound was used in 29% of 189 laparoscopic cholecystectomies. During 2004, ultrasound was used in 77% of 66 laparoscopic cholecystectomies. Throughout both periods, fluoroscopy was only used during 6 laparoscopic common bile duct explorations (2.4% of all cases). There were no false-positive or -negative ultrasounds, and there were no bile duct injuries. As experience with ultrasound cholangiography increases, there is little indication for fluoroscopic cholangiography except for rare questions concerning anatomy and during therapeutic maneuvers for common bile duct stones.

  15. Successful treatment of limy bile syndrome extending to the common bile duct by laparoscopic cholecystectomy and common bile duct exploration: A case report and literature review.

    PubMed

    Masuda, Yuka; Mizuguchi, Yoshiaki; Kanda, Tomohiro; Furuki, Hiroyasu; Mamada, Yasuhiro; Taniai, Nobuhiko; Nakamura, Yoshiharu; Yoshioka, Masato; Matsushita, Akira; Kawano, Yoichi; Shimizu, Tetsuya; Uchida, Eiji

    2017-02-01

    Limy bile syndrome extending to the common bile duct (CBD) is a rare condition that lacks a standardized treatment. Laparoscopic cholecystectomy with laparoscopic choledocholithotomy by CBD exploration is preferred because it preserves the function of the sphincter of the Vater's papilla and allows treatment of both lesions. A 37-year-old man who was receiving entecavir for chronic hepatitis B developed right upper quadrant pain. Abdominal ultrasonography revealed a calcified shadow in the gallbladder and CBD. Abdominal imaging revealed a liquid-like material identified by a calcified shadow in two phases separated by a fluid-fluid level. Abdominal and 3-D drip infusion cholangiography CT showed stones in the gallbladder and CBD with limy bile. The patient underwent laparoscopic cholecystectomy and choledocholithotomy. Intraoperatively, white-yellow-colored bile and stones were drained from the CBD. A C-tube was placed. Postoperatively, remnant stones and radiopaque materials were absent. The stones comprised of >95% calcium carbonate. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  16. Side-by-side placement of bilateral endoscopic metal stents for the treatment of postoperative biliary stricture.

    PubMed

    Kaino, Seiji; Sen-Yo, Manabu; Shinoda, Shuhei; Kawano, Michitaka; Harima, Hirofumi; Suenaga, Shigeyuki; Sakaida, Isao

    2017-02-01

    Postoperative biliary strictures are usually complications of cholecystectomy. Endoscopic plastic stent prosthesis is generally undertaken for treating benign biliary strictures. Recently, fully covered metal stents have been shown to be effective for treating benign distal biliary strictures. We present the case of a 53-year-old woman with liver injury in which imaging studies showed a common hepatic duct stricture. Endoscopic retrograde cholangiopancreatography also confirmed the presence of a common hepatic duct stricture. Temporally fully covered metal stents with dilated diameters of 6 mm were placed in a side-by-side fashion in the left and right hepatic ducts, respectively. We removed the stents 2 months after their placement. Subsequent cholangiography revealed an improvement in the biliary strictures. Although we were apprehensive about the fully covered metal stents obstructing the biliary side branches, we noted that careful placement of the bilateral metal stents did not cause any complications. Side-by-side deployment of bilateral endoscopic fully covered metal stents can be one of the safe and effective therapies for postoperative biliary stricture.

  17. Pancreaticopleural fistula: etiology, treatment and long-term follow-up.

    PubMed

    Roberts, Keith J; Sheridan, Maria; Morris-Stiff, Gareth; Smith, Andrew M

    2012-04-01

    Pancreaticopleural fistula (PPF) are uncommon. Complex multidisciplinary treatment is required due to nutritional compromise and sepsis. This is the first description of long-term follow-up of patients with PPF. Eleven patients with PPF treated at a specialist unit were identified. Causation, investigation, treatment and outcomes were recorded. Pancreatitis was the etiology of the PPF in 9 patients, and in the remaining 2 the PPF developed following distal pancreatectomy. Cross-sectional imaging demonstrated the site of duct disruption in 10 cases, with endoscopic retrograde cholangiopancreatography identifying the final case. Suppression of pancreatic exocrine secretion and percutaneous drainage formed the mainstay of treatment.Five cases resolved following pancreatic duct stent insertion and three patients required surgical treatment for established empyema. There were no complications. In all cases that resolved there has been no recurrence of PPF over a median follow-up of 50 months (range 15-62). PPF is an uncommon event complicating pancreatitis or pancreatectomy; pancreatic duct disruption is the common link. A step-up approach consisting of minimally invasive techniques treats the majority with surgery needed for refractory sepsis.

  18. Pathological Studies of “Sudden Death Syndrome” in Broiler Chickens

    PubMed Central

    Ononiwu, J.C.; Thomson, R.G.; Carlson, H.C.; Julian, R.J.

    1979-01-01

    Sudden death syndrome usually occurs in heavy, fast-growing and healthy-looking broilers. Most of the affected birds are males. The characteristic necropsy changes are seen in well-fleshed broilers with edema and generalized pulmonary congestion, recently ingested feed in the crop and gizzard, distended intestine with creamy content and empty gall bladder. The liver and kidneys are slightly enlarged and the latter have patchy areas of subcapsular hemorrhage. The heart contains clotted blood in the atria but the ventricles are often empty and the left ventricle in particular assumes a hypertrophied appearance. Microscopic examination of heart muscle reveals degeneration of fibers, separation of cardiac muscle fibers by edema and infiltration of heterophils. The lungs have severe vascular congestion, inflammatory cell infiltration in the mucosa of the secondary bronchi and edema fluid in the tertiary bronchi and interlobular connective tissue. The liver has moderate bile duct hyperplasia, periportal hepatitis and mononuclear cell infiltration adjacent to bile ducts which possibly leads to bile duct constriction. The kidneys have subcapsular and parenchymatous hemorrhage. ImagesFIGURE 1.FIGURE 2. PMID:436100

  19. Intraductal ultrasonographic anatomy of biliary varices in patients with portal hypertension.

    PubMed

    Takagi, Tadayuki; Irisawa, Atsushi; Shibukawa, Goro; Hikichi, Takuto; Obara, Katsutoshi; Ohira, Hiromasa

    2015-01-01

    The term, portal biliopathy, denotes various biliary abnormalities, such as stenosis and/or dilatation of the bile duct, in patients with portal hypertension. These vascular abnormalities sometimes bring on an obstructive jaundice, but they are not clear which vessels participated in obstructive jaundice. The aim of present study was clear the bile ductal changes in patients with portal hypertension in hopes of establishing a therapeutic strategy for obstructive jaundice caused by biliary varices. Three hundred and thirty-seven patients who underwent intraductal ultrasound (IDUS) during endoscopic retrograde cholangiography for biliary abnormalities were enrolled. Portal biliopathy was analyzed using IDUS. Biliary varices were identified in 11 (2.7%) patients. IDUS revealed biliary varices as multiple, hypoechoic features surrounding the bile duct wall. These varices could be categorized into one of two groups according to their location in the sectional image of bile duct: epicholedochal and paracholedochal. Epicholedochal varices were identified in all patients, but paracholedochal varices were observed only in patients with extrahepatic portal obstruction. IDUS was useful to characterize the anatomy of portal biliopathy in detail.

  20. Persistent Mullerian duct syndrome with transverse testicular ectopia and seminoma.

    PubMed

    Alp, Bilal Fırat; Demirer, Zafer; Gürağaç, Ali; Babacan, Oğuzhan; Sarı, Erkan; Sarı, Sebahattin; Yavan, Ibrahim

    2014-08-01

    Persistent Mullerian duct syndrome (PMDS) is a rare form of the 46 XY disorders of sexual differentiation, characterized by the presence of a uterus and fallopian tubes due to the failure of Mullerian duct regression in genotypically normal males. More than 150 cases have been recorded, most of them in adults. In most cases, the PMDS is discovered during surgery for inguinal hernia or cryptorchidism, or by the presence of transverse testicular ectopia (TTE). The presence of PMDS with TTE is even more uncommon. In TTE, both testes descend through the same inguinal canal into the same scrotal sac. Patients with TTE present with symptoms of unilateral cryptorchidism and a contralateral inguinal hernia. For patients with inguinal hernia and cryptorchidism associated with TTE, PMDS should be kept in mind, and radiologic evaluation such as ultrasonography or magnetic resonance imaging of the genitourinary system and karyotyping are recommended. Whereas radiologic evaluation could be helpful in the diagnosis of TTE, it cannot diagnose the malignancy itself. The case explained in this report will offer urologists additional useful treatment strategies for patients with inguinal hernia and cryptorchidism.

  1. Hemorrhagic Cholecystitis in a Patient on Maintenance Dialysis

    PubMed Central

    Shishida, Masayuki; Ikeda, Masahiro; Karakuchi, Nozomi; Ono, Kosuke; Tsukiyama, Naofumi; Shimomura, Manabu; Oishi, Koichi; Miyamoto, Kazuaki; Toyota, Kazuhiro; Sadamoto, Seiji; Takahashi, Tadateru

    2017-01-01

    The present paper describes a case of hemorrhagic cholecystitis in a patient on maintenance dialysis. The patient presented with right upper quadrant abdominal pain. Computed tomography revealed swelling of the gallbladder, high- and isodensity contents of the gallbladder, and high-density stone in the gallbladder neck. He was hospitalized for suspected acute cholecystitis. After hospitalization, his levels of total bilirubin, aspartate aminotransferase, and alanine aminotransferase increased. T2-weighted magnetic resonance imaging showed low-intensity contents expanded to include a wide area from the common bile duct to the cystic duct and gallbladder neck. Endoscopic retrograde cholangiopancreatography revealed clotting from the duodenal papilla. After cannulation of the bile duct, old blood and pus began to flow from the mammary papilla, and an endoscopic nasobiliary drainage tube was placed. After his liver function had improved, the patient underwent laparoscopic cholecystectomy. His sample revealed that the gallbladder was filled with blood clots and stones. His postoperative course was uneventful and he was discharged on day 19 after the procedure. Although hemorrhagic cholecystitis is rare, it should be considered as a differential diagnosis for patients on dialysis who have acute abdominal symptoms. PMID:29033767

  2. Hilar cholangiocarcinoma: Cross sectional evaluation of disease spectrum

    PubMed Central

    Mahajan, Mangal S; Moorthy, Srikanth; Karumathil, Sreekumar P; Rajeshkannan, R; Pothera, Ramchandran

    2015-01-01

    Although hilar cholangiocarcinoma is relatively rare, it can be diagnosed on imaging by identifying its typical pattern. In most cases, the tumor appears to be centered on the right or left hepatic duct with involvement of the ipsilateral portal vein, atrophy of hepatic lobe on that side, and invasion of adjacent liver parenchyma. Multi-detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) are commonly used imaging modalities to assess the longitudinal and horizontal spread of tumor. PMID:25969643

  3. Surgical approaches to chronic pancreatitis: indications and imaging findings.

    PubMed

    Hafezi-Nejad, Nima; Singh, Vikesh K; Johnson, Stephen I; Makary, Martin A; Hirose, Kenzo; Fishman, Elliot K; Zaheer, Atif

    2016-10-01

    Chronic pancreatitis (CP) is an irreversible, inflammatory process characterized by progressive fibrosis of the pancreas that can result in abdominal pain, exocrine insufficiency, and diabetes. Inadequate pain relief using medical and/or endoscopic therapies is an indication for surgery. The surgical management of CP is centered around three main operations including pancreaticoduodenectomy (PD), duodenum-preserving pancreatic head resection (DPPHR) and drainage procedures, and total pancreatectomy with islet autotransplantation (TPIAT). PD is the method of choice when there is a high suspicion for malignancy. Combined drainage and resection procedures are associated with pain relief, higher quality of life, and superior short-term and long-term survival in comparison with the PD. TPIAT is a reemerging treatment that may be promising in subjects with intractable pain and impaired quality of life. Imaging examinations have an extensive role in pre-operative and post-operative evaluation of CP patients. Pre-operative advanced imaging examinations including CT and MRI can detect hallmarks of CP such as calcifications, pancreatic duct dilatation, chronic pseudocysts, focal pancreatic enlargement, and biliary ductal dilatation. Post-operative findings may include periportal hepatic edema, pneumobilia, perivascular cuffing and mild pancreatic duct dilation. Imaging can also be useful in the detection of post-operative complications including obstructions, anastomotic leaks, and vascular lesions. Imaging helps identify unique post-operative findings associated with TPIAT and may aid in predicting viability and function of the transplanted islet cells. In this review, we explore surgical indications as well as pre-operative and post-operative imaging findings associated with surgical options that are typically performed for CP patients.

  4. The Harderian gland, its secretory duct and porphyrin content in the mongolian gerbil (Meriones unguiculatus).

    PubMed Central

    Johnston, H S; McGadey, J; Thompson, G G; Moore, M R; Payne, A P

    1983-01-01

    The Harderian gland, its secretory duct and porphyrin content were examined in the mongolian gerbil (Meriones unguiculatus). The gland consisted of tubules lined by a single layer of epithelial cells and a myoepithelial network. The tubule cells were often binucleate and possessed lipid vacuoles in the apical half of the cell, a corona of granular endoplasmic reticulum surrounding the nucleus, and cytoplasmic 'slashes'. The latter are probably derived from dense membranous couplets and may be precursors of the lipid vacuoles. Holocrine and merocrine secretion was observed. Interstitial cells included plasma cells, mast cells and (predominantly) melanocytes which render the gland black. The gland was surrounded by a collagen capsule and an outer layer of highly attenuated (possibly endothelioid) cells. Within the gland, the secretory duct was lined by a single layer of normal tubule cells. Outside the gland, the duct enlarged to form an ampulla, from which clefts led off to deep crypts. The ampulla and clefts were lined by cells with small dense apical granules and stubby microvilli; some possessed lipid vacuoles. The crypts were lined by serous cells with active Golgi regions. At the duct opening, ampullary cells became squamous and goblet cells occurred. Geometric crystalloid deposits (with a layered structure of 7.6 nm periodicity) occurred at cleft-crypt junctions. Islets of extra-glandular ductal tissue were occasionally found within the gland. Porphyrins were detectable both by chemical assay and fluorescence microscopy. There was a trend for female glands to have a higher content than males. Solid intraluminal accretions of porphyrin and/or lipid were present. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 PMID:6654750

  5. Detection of benign hilar bile duct stenoses - A retrospective analysis in 250 patients with suspicion of Klatskin tumour.

    PubMed

    Scheuermann, Uwe; Widyaningsih, Rizky; Hoppe-Lotichius, Maria; Heise, Michael; Otto, Gerd

    2016-06-01

    The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and multivariate analyses of 18 clinicopathological parameters revealed that patient age, serum alkaline phosphatase, tumour marker CA19-9 and presence of tumour mass in computed tomography were independent predictors for malignant biliary stenoses (p < 0.05). Receiver operator characteristic curve showed that a CA19-9 serum level of 61.2 U/ml or more has a sensitivity, specificity and diagnostic accuracy for predicting the malignant nature of the hilar biliary stenoses of 74.6%, 80.0% and 83.5%, respectively. Surgical resection could be avoided by preoperative work-up and surgical exploration in 10 out of 34 patients with benign lesions. Rates of major liver resections performed were 66.7% in the benign lesion group and 90.7% in the Klatskin tumour group. Despite improvements of preoperative diagnostics, it remains difficult to differentiate between benign and malignant hilar bile duct stenosis. Even explorative laparotomy was not able to safely exclude Klatskin tumour in all cases and therefore major liver resection was inevitable.

  6. Gallstones and common bile duct calculi in infancy and childhood.

    PubMed

    Kumar, R; Nguyen, K; Shun, A

    2000-03-01

    Gallstones and common bile duct calculi have been increasingly diagnosed in recent years in infants and children. The present study aims to review the spectrum of this disorder in the last two decades. During the period 1979-96 a total of 102 consecutive infants and children were diagnosed in Royal Alexandra Hospital for Children with gallstones or common bile duct calculi. A detailed retrospective analysis and follow-up of these children form the basis of the present report. The median age at presentation was 10 years. Recurrent right upper quadrant pain was the most common clinical presentation. The male-to-female ratio was 3:2 and this male predominance was noted in all the age groups. Aetiologically three identifiable groupings were noted: idiopathic disease (n = 66), haematological diseases (n = 23) and specific non-haematological disease (n = 13). The incidence of idiopathic and haematological stones had increased two-fold in the second half of the study. The majority of children (86%) underwent surgical correction. Choledocholithiasis (CDL) was noted in 18 children (18%). Jaundice was commonly associated with abdominal pain in this group. A higher incidence of common bile duct calculi was noted in females and children less than 5 years of age (P < 0.01). Common bile duct calculi were accurately diagnosed by pre-operative imaging in all 18 children. Surgical correction was required in all except two. The present study suggests an increasing incidence of gallstones in children. Cholelithiasis in children occurs commonly in boys, is idiopathic in aetiology and presents with a vague right upper quadrant pain. Choledocholithiasis is not uncommon in children, occurs more commonly in girls aged < 5 years and presents with jaundice or abnormal liver function tests.

  7. Pancreatic trauma.

    PubMed

    Lahiri, R; Bhattacharya, S

    2013-05-01

    Pancreatic trauma occurs in approximately 4% of all patients sustaining abdominal injuries. The pancreas has an intimate relationship with the major upper abdominal vessels, and there is significant morbidity and mortality associated with severe pancreatic injury. Immediate resuscitation and investigations are essential to delineate the nature of the injury, and to plan further management. If main pancreatic duct injuries are identified, specialised input from a tertiary hepatopancreaticobiliary (HPB) team is advised. A comprehensive online literature search was performed using PubMed. Relevant articles from international journals were selected. The search terms used were: 'pancreatic trauma', 'pancreatic duct injury', 'radiology AND pancreas injury', 'diagnosis of pancreatic trauma', and 'management AND surgery'. Articles that were not published in English were excluded. All articles used were selected on relevance to this review and read by both authors. Pancreatic trauma is rare and associated with injury to other upper abdominal viscera. Patients present with non-specific abdominal findings and serum amylase is of little use in diagnosis. Computed tomography is effective in diagnosing pancreatic injury but not duct disruption, which is most easily seen on endoscopic retrograde cholangiopancreaticography or operative pancreatography. If pancreatic injury is suspected, inspection of the entire pancreas and duodenum is required to ensure full evaluation at laparotomy. The operative management of pancreatic injury depends on the grade of injury found at laparotomy. The most important prognostic factor is main duct disruption and, if found, reconstructive options should be determined by an experienced HPB surgeon. The diagnosis of pancreatic trauma requires a high index of suspicion and detailed imaging studies. Grading pancreatic injury is important to guide operative management. The most important prognostic factor is pancreatic duct disruption and in these cases, experienced HPB surgeons should be involved. Complications following pancreatic trauma are common and the majority can be managed without further surgery.

  8. Large bilateral seminal vesicle calculi presenting with spermolithiasis.

    PubMed

    Williams, Sarah Anne; Christodoulidou, Michelle; Nigam, Raj

    2017-06-02

    A 34-year-old male presented with an 8-month history of passing increasingly painful 'grit' in his ejaculate. Semen analysis was normal as were urinary and blood tests. T1-weighted MRI revealed several bilateral high-signal areas measuring up to 1 cm in diameter, located in the seminal vesicles. These were confirmed as calculi on T2-weighted imaging and a seminal vesiculogram, with no drainage from the left ejaculatory duct and only minimal from the right duct. He is currently awaiting a robot-assisted laparoscopic vesiculotomy after completion of family. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. A case of distal extrahepatic cholangiocarcinoma with two positive resection margins

    PubMed Central

    Warner, Wayne A.; Ramcharan, Wesley; Harnanan, Dave; Umakanthan, Srikanth; Maharaj, Ravi

    2016-01-01

    Cholangiocarcinoma is an uncommon primary malignancy of the biliary tract that is challenging to diagnose and treat effectively due to its relatively silent and late clinical presentation. The present study reports a case of a 60-year-old male with distal extrahepatic cholangiocarcinoma with a 3-week history of painless obstructive jaundice symptoms and subjective weight loss. Imaging revealed an obstructing lesion in the common bile duct, just distal to the entrance of the cystic duct. Pathology revealed moderately differentiated cholangiocarcinoma with two positive proximal resection margins. The two positive resection margins presented a challenge during surgery and points to an urgent need for further studies to better illuminate diagnostic and therapeutic options for patients with similar clinicopathological presentation. PMID:27895774

  10. A case of distal extrahepatic cholangiocarcinoma with two positive resection margins.

    PubMed

    Warner, Wayne A; Ramcharan, Wesley; Harnanan, Dave; Umakanthan, Srikanth; Maharaj, Ravi

    2016-11-01

    Cholangiocarcinoma is an uncommon primary malignancy of the biliary tract that is challenging to diagnose and treat effectively due to its relatively silent and late clinical presentation. The present study reports a case of a 60-year-old male with distal extrahepatic cholangiocarcinoma with a 3-week history of painless obstructive jaundice symptoms and subjective weight loss. Imaging revealed an obstructing lesion in the common bile duct, just distal to the entrance of the cystic duct. Pathology revealed moderately differentiated cholangiocarcinoma with two positive proximal resection margins. The two positive resection margins presented a challenge during surgery and points to an urgent need for further studies to better illuminate diagnostic and therapeutic options for patients with similar clinicopathological presentation.

  11. Magnetic resonance imaging of the pediatric neck: an overview.

    PubMed

    Shekdar, Karuna V; Mirsky, David M; Kazahaya, Ken; Bilaniuk, Larissa T

    2012-08-01

    Evaluation of neck lesions in the pediatric population can be a diagnostic challenge, for which magnetic resonance (MR) imaging is extremely valuable. This article provides an overview of the value and utility of MR imaging in the evaluation of pediatric neck lesions, addressing what the referring clinician requires from the radiologist. Concise descriptions and illustrations of MR imaging findings of commonly encountered pathologic entities in the pediatric neck, including abnormalities of the branchial apparatus, thyroglossal duct anomalies, and neoplastic processes, are given. An approach to establishing a differential diagnosis is provided, and critical points of information are summarized. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Novel ex vivo model for hands-on teaching of and training in EUS-guided biliary drainage: creation of "Mumbai EUS" stereolithography/3D printing bile duct prototype (with videos).

    PubMed

    Dhir, Vinay; Itoi, Takao; Fockens, Paul; Perez-Miranda, Manuel; Khashab, Mouen A; Seo, Dong Wan; Yang, Ai Ming; Lawrence, Khek Yu; Maydeo, Amit

    2015-02-01

    EUS-guided biliary drainage (EUS-BD) has emerged as an alternative rescue method in patients with failed ERCP. Opportunities for teaching and training are limited because of a low case volume at most centers. To evaluate a stereolithography/3-dimensional (3D) printing bile duct prototype for teaching and training in EUS-BD. Prospective observational feasibility study. Tertiary referral center. Twenty endosonographers attending an interventional EUS workshop. A prototype of a dilated biliary system was prepared by computer-aided design and 3D printing. The study participants performed guidewire manipulation and EUS-BD procedures (antegrade procedure and/or choledochoduodenostomy) on the prototype. Participants were scored with the device on a scale of 1 to 5 via a questionnaire. Participants' success rate for various steps of the EUS-BD procedure was noted. Subjective and objective evaluation of the prototype regarding its overall applicability, quality of radiographic and EUS images, and 4 steps of EUS-BD procedure (needle puncture, guidewire manipulation, tract dilation, stent placement). Fifteen participants returned the questionnaire, and 10 completed all 4 steps of EUS-BD. The median score for overall utility was 4, whereas that for EUS and US views was 5. Participants with experience in performing more than 20 EUS-BD procedures scored the prototype significantly lower for stent placement (P = .013) and equivalent for needle puncture, tract dilation, and wire manipulation. The success rate of various steps was 100% for needle puncture and tract dilation, 82.35% for wire manipulation, and 80% for stent placement. The mean overall procedure time was 18 minutes. Small number of participants. The 3D printing bile duct prototype appears suitable for teaching of and training in the various steps of EUS-BD. Further studies are required to elucidate its role. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  13. Flow design and simulation of a gas compression system for hydrogen fusion energy production

    NASA Astrophysics Data System (ADS)

    Avital, E. J.; Salvatore, E.; Munjiza, A.; Suponitsky, V.; Plant, D.; Laberge, M.

    2017-08-01

    An innovative gas compression system is proposed and computationally researched to achieve a short time response as needed in engineering applications such as hydrogen fusion energy reactors and high speed hammers. The system consists of a reservoir containing high pressure gas connected to a straight tube which in turn is connected to a spherical duct, where at the sphere’s centre plasma resides in the case of a fusion reactor. Diaphragm located inside the straight tube separates the reservoir’s high pressure gas from the rest of the plenum. Once the diaphragm is breached the high pressure gas enters the plenum to drive pistons located on the inner wall of the spherical duct that will eventually end compressing the plasma. Quasi-1D and axisymmetric flow formulations are used to design and analyse the flow dynamics. A spike is designed for the interface between the straight tube and the spherical duct to provide a smooth geometry transition for the flow. Flow simulations show high supersonic flow hitting the end of the spherical duct, generating a return shock wave propagating upstream and raising the pressure above the reservoir pressure as in the hammer wave problem, potentially giving temporary pressure boost to the pistons. Good agreement is revealed between the two flow formulations pointing to the usefulness of the quasi-1D formulation as a rapid solver. Nevertheless, a mild time delay in the axisymmetric flow simulation occurred due to moderate two-dimensionality effects. The compression system is settled down in a few milliseconds for a spherical duct of 0.8 m diameter using Helium gas and a uniform duct cross-section area. Various system geometries are analysed using instantaneous and time history flow plots.

  14. Methyl Jasmonate Induces Traumatic Resin Ducts, Terpenoid Resin Biosynthesis, and Terpenoid Accumulation in Developing Xylem of Norway Spruce Stems1

    PubMed Central

    Martin, Diane; Tholl, Dorothea; Gershenzon, Jonathan; Bohlmann, Jörg

    2002-01-01

    Norway spruce (Picea abies L. Karst) produces an oleoresin characterized by a diverse array of terpenoids, monoterpenoids, sesquiterpenoids, and diterpene resin acids that can protect conifers against potential herbivores and pathogens. Oleoresin accumulates constitutively in resin ducts in the cortex and phloem (bark) of Norway spruce stems. De novo formation of traumatic resin ducts (TDs) is observed in the developing secondary xylem (wood) after insect attack, fungal elicitation, and mechanical wounding. Here, we characterize the methyl jasmonate-induced formation of TDs in Norway spruce by microscopy, chemical analyses of resin composition, and assays of terpenoid biosynthetic enzymes. The response involves tissue-specific differentiation of TDs, terpenoid accumulation, and induction of enzyme activities of both prenyltransferases and terpene synthases in the developing xylem, a tissue that constitutively lacks axial resin ducts in spruce. The induction of a complex defense response in Norway spruce by methyl jasmonate application provides new avenues to evaluate the role of resin defenses for protection of conifers against destructive pests such as white pine weevils (Pissodes strobi), bark beetles (Coleoptera, Scolytidae), and insect-associated tree pathogens. PMID:12114556

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  16. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...

  17. Ultrasonography of Various Thyroid Diseases in Children and Adolescents: A Pictorial Essay

    PubMed Central

    Lee, Eun Hye; Jeong, Sun Hye; Park, Jisang; Lee, Heon

    2015-01-01

    Thyroid imaging is indicated to evaluate congenital hypothyroidism during newborn screening or in cases of a palpable thyroid mass in children and adolescents. This pictorial essay reviews the ultrasonography (US) of thyroid diseases in children and adolescents, including normal thyroid gland development, imaging features of congenital thyroid disorders (dysgenesis, [aplasia, ectopy, hypoplasia], dyshormonogenesis, transient hypothyroidism, thyroglossal duct cyst), diffuse thyroid disease (Grave's disease, Hashimoto's thyroiditis, and suppurative thyroiditis), and thyroid nodules. The primary imaging modalities for evaluating thyroid diseases are US and radionuclide scintigraphy. Additionally, US can be used to guide aspiration of detected nodules. PMID:25741204

  18. Image-guided surgery using near-infrared fluorescent light: from bench to bedside

    NASA Astrophysics Data System (ADS)

    Boogerd, Leonora S. F.; Handgraaf, Henricus J. M.; van de Velde, Cornelis J. H.; Vahrmeijer, Alexander L.

    2015-03-01

    Due to its relatively high tissue penetration, near-infrared (NIR; 700-900 nm) fluorescent light has the potential to visualize structures that need to be resected (e.g. tumors, lymph nodes) and structures that need to be spared (e.g. nerves, ureters, bile ducts). Until now, most clinical trials have focused on suboptimal, non-targeted dyes. Although successful, a new era in image-guided surgery has begun by the introduction of tumor-targeted agents. In this paper, we will describe how tumor-targeted NIR fluorescent imaging can be applied in a clinical setting.

  19. Endoscopic ultrasound in common bile duct dilatation with normal liver enzymes

    PubMed Central

    De Angelis, Claudio; Marietti, Milena; Bruno, Mauro; Pellicano, Rinaldo; Rizzetto, Mario

    2015-01-01

    In recent years, the description of isolated bile duct dilatation has been increasingly observed in subjects with normal liver function tests and nonspecific abdominal symptoms, probably due to the widespread use of high-resolution imaging techniques. However, there is scant literature about the evolution of this condition and the impact of endoscopic ultrasound (EUS) in the diagnostic work up. When noninvasive imaging tests (transabdominal ultrasound, computed tomography or magnetic resonance cholangiopancreatography) fail to identify the cause of dilatation and clinical or biochemical alarm signs are absent, the probability of having biliary disease is considered low. In this setting, using EUS, the presence of pathologic findings (choledocholithiasis, strictures, chronic pancreatitis, ampullary or pancreatic tumors, cholangiocarcinoma), not always with a benign course, has been observed. The aim of this review has been to evaluate the prevalence of disease among non-jaundiced patients without signs of cytolysis and/or cholestasis and the assessment of EUS yield. Data point out to a promising role of EUS in the identification of a potential biliary pathology. EUS is a low invasive technique, with high accuracy, that could play a double cost-effective role: identifying pathologic conditions with dismal prognosis, in asymptomatic patients with negative prior imaging tests, and excluding pathologic conditions and further follow-up in healthy subjects. PMID:26191344

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klingensmith, W.C.; Spitzer, W.M.; Fritzberg, A.R.

    Diisopropyl-IDA TC 99m imaging studies were performed in 11 normal subjects in both the fasting and postprandial states. In 5- to 60-minute analog images obtained in both fasting and postprandial studies, the cardiac blood pool was almost never seen, renal pelvic radioactivity was commonly seen, the extrahepatic biliary tract was always seen, and the left hepatic duct was always more prominent than the right hepatic duct. The billiary tract was visualized by ten minutes in nine of 11 fasting studies and 10 of 11 postprandial studies. The gallbladder was visualized in all eleven fasting studies, but in only four postprandialmore » studies (p<0.05). The zero- to sixty-minute digital data indicated a greater hepatocyte clearance, an earlier time of peak parenchymal radioactivity, and a faster parenchymal washout in the postprandial studies compared with fasting studies (p<0.05). Approximately nine percent of the injected dose was recovered in the urine during the first three hours in fasting and postprandial studies. The normal diisopropyl-IDA Tc 99m study in the fasting and postprandial states is defined; significant differences exist between the two states.« less

  1. Unstructured grid research and use at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Potapczuk, Mark G.

    1993-01-01

    Computational fluid dynamics applications of grid research at LRC include inlets, nozzles, and ducts; turbomachinery; propellers - ducted and unducted; and aircraft icing. Some issues related to internal flow grid generation are resolution requirements on several boundaries, shock resolution vs. grid periodicity, grid spacing at blade/shroud gap, grid generation in turbine blade passages, and grid generation for inlet/nozzle geometries. Aircraft icing grid generation issues include (1) small structures relative to airfoil chord must be resolved; (2) excessive number of grid points in far-field using structured grid; and (3) grid must be recreated as ice shape grows.

  2. X based interactive computer graphics applications for aerodynamic design and education

    NASA Technical Reports Server (NTRS)

    Benson, Thomas J.; Higgs, C. Fred, III

    1995-01-01

    Six computer applications packages have been developed to solve a variety of aerodynamic problems in an interactive environment on a single workstation. The packages perform classical one dimensional analysis under the control of a graphical user interface and can be used for preliminary design or educational purposes. The programs were originally developed on a Silicon Graphics workstation and used the GL version of the FORMS library as the graphical user interface. These programs have recently been converted to the XFORMS library of X based graphics widgets and have been tested on SGI, IBM, Sun, HP and PC-Lunix computers. The paper will show results from the new VU-DUCT program as a prime example. VU-DUCT has been developed as an educational package for the study of subsonic open and closed loop wind tunnels.

  3. Pancreaticobiliary maljunction and biliary cancer.

    PubMed

    Kamisawa, Terumi; Kuruma, Sawako; Tabata, Taku; Chiba, Kazuro; Iwasaki, Susumu; Koizumi, Satomi; Kurata, Masanao; Honda, Goro; Itoi, Takao

    2015-03-01

    Pancreaticobiliary maljunction (PBM) is a congenital malformation in which the pancreatic and bile ducts join anatomically outside the duodenal wall. Japanese clinical practice guidelines on how to deal with PBM were made in 2012, representing a world first. According to the 2013 revision to the diagnostic criteria for PBM, in addition to direct cholangiography, diagnosis can be made by magnetic resonance cholangiopancreatography (MRCP), 3-dimensional drip infusion cholangiography computed tomography, endoscopic ultrasonography (US), or multiplanar reconstruction images by multidetector row computed tomography. In PBM, the common channel is so long that sphincter action does not affect the pancreaticobiliary junction, and pancreatic juice frequently refluxes into the biliary tract. Persistence of refluxed pancreatic juice injures epithelium of the biliary tract and promotes cancer development, resulting in higher rates of carcinogenesis in the biliary tract. In a nationwide survey, biliary cancer was detected in 21.6% of adult patients with congenital biliary dilatation (bile duct cancer, 32.1% vs. gallbladder cancer, 62.3%) and in 42.4% of PBM patients without biliary dilatation (bile duct cancer, 7.3% vs. gallbladder cancer, 88.1%). Pathophysiological conditions due to pancreatobiliary reflux occur in patients with high confluence of pancreaticobiliary ducts, a common channel ≥6 mm long, and occlusion of communication during contraction of the sphincter. Once the diagnosis of PBM is established, immediate prophylactic surgery is recommended. However, the surgical strategy for PBM without biliary dilatation remains controversial. To detect PBM without biliary dilatation early, MRCP is recommended for patients showing gallbladder wall thickening on screening US under suspicion of PBM.

  4. Endotherapy is effective for pancreatic ductal disruption: A dual center experience.

    PubMed

    Das, Rohit; Papachristou, Georgios I; Slivka, Adam; Easler, Jeffrey J; Chennat, Jennifer; Malin, Jessica; Herman, Justin B; Laique, Sobia N; Hayat, Umar; Ooi, Yinn Shaung; Rabinovitz, Mordechai; Yadav, Dhiraj; Siddiqui, Ali A

    2016-01-01

    Pancreatic duct (PD) disruptions occur as a result of different etiologies and can be managed medically, endoscopically, or surgically. The aim of this study was to provide an evaluation on the efficacy of endotherapy for treatment of PD disruption in a large cohort of patients and identify factors that predict successful treatment outcome. We retrospectively evaluated consecutive patients who underwent endoscopic retrograde pancreatography (ERP) for transpapillary pancreatic stent placement for PD disruption from 2008 to 2013 at two tertiary referral institutions. PD disruption was defined as extravasation of contrast from the pancreatic duct as seen on ERP. Therapeutic success was defined by resolution of PD leak on ERP, clinical, and/or imaging evaluation. We evaluated 107 patients (58% male, mean age 53 years) with PD disruption. Etiologies of PD disruption were acute pancreatitis (36%), post-operative (31%), chronic pancreatitis (29%), and trauma (4%). PD disruption was successfully bridged by a stent in 45 (44%) patients. Two patients developed post-sphincterotomy bleeding, two had stent migration, and two patients died as a result of post-ERP related complications. Placement of a PD stent was successful in 103/107 (96%) patients. Therapeutic success was achieved in 80/107 (75%) patients. Non-acute pancreatitis etiologies and absence of complete duct disruption were independent predictors of therapeutic success. Endoscopic therapy using a transpapillary stent for PD disruption is safe and effective. Absence of complete duct disruption and non-AP etiologies determine a favorable endoscopic outcome. Published by Elsevier India Pvt Ltd.

  5. The Dynamics of Controlled Flow Separation within a Diverter Duct Diffuser

    NASA Astrophysics Data System (ADS)

    Peterson, C. J.; Vukasinovic, B.; Glezer, A.

    2016-11-01

    The evolution and receptivity to fluidic actuation of the flow separation within a rectangular, constant-width, diffuser that is branched off of a primary channel is investigated experimentally at speeds up to M = 0.4. The coupling between the diffuser's adverse pressure gradient and the internal separation that constricts nearly half of the flow passage through the duct is controlled using a spanwise array of fluidic actuators on the surface upstream of the diffuser's inlet plane. The dynamics of the separating surface vorticity layer in the absence and presence of actuation are investigated using high-speed particle image velocimetry combined with surface pressure measurements and total pressure distributions at the primary channel's exit plane. It is shown that the actuation significantly alters the incipient dynamics of the separating vorticity layer as the characteristic cross stream scales of the boundary layer upstream of separation and of the ensuing vorticity concentrations within the separated flow increase progressively with actuation level. It is argued that the dissipative (high frequency) actuation alters the balance between large- and small-scale motions near separation by intensifying the large-scale motions and limiting the small-scale dynamics. Controlling separation within the diffuser duct also has a profound effect on the global flow. In the presence of actuation, the mass flow rate in the primary duct increases 10% while the fraction of the diverted mass flow rate in the diffuser increases by more than 45% at 0.7% actuation mass fraction. Supported by the Boeing Company.

  6. Composite load spectra for select space propulsion structural components

    NASA Technical Reports Server (NTRS)

    Newell, James F.; Ho, Hing W.

    1991-01-01

    This report summarizes the development for: (1) correlation fields; (2) applications to liquid oxygen post; (3) models for pressure fluctuatios and vibration loads fluctuations; (4) additions to expert systems; and (5) scaling criteria. Implementation to computer code is also described. Demonstration sample cases are included with additional applications to engine duct and pipe bend.

  7. Dual-mode transducers for ultrasound imaging and thermal therapy.

    PubMed

    Owen, N R; Chapelon, J Y; Bouchoux, G; Berriet, R; Fleury, G; Lafon, C

    2010-02-01

    Medical imaging is a vital component of high intensity focused ultrasound (HIFU) therapy, which is gaining clinical acceptance for tissue ablation and cancer therapy. Imaging is necessary to plan and guide the application of therapeutic ultrasound, and to monitor the effects it induces in tissue. Because they can transmit high intensity continuous wave ultrasound for treatment and pulsed ultrasound for imaging, dual-mode transducers aim to improve the guidance and monitoring stages. Their primary advantage is implicit registration between the imaging and treatment axes, and so they can help ensure before treatment that the therapeutic beam is correctly aligned with the planned treatment volume. During treatment, imaging signals can be processed in real-time to assess acoustic properties of the tissue that are related to thermal ablation. Piezocomposite materials are favorable for dual-mode transducers because of their improved bandwidth, which in turn improves imaging performance while maintaining high efficiency for treatment. Here we present our experiences with three dual-mode transducers for interstitial applications. The first was an 11-MHz monoelement designed for use in the bile duct. It had a 25x7.5 mm(2) aperture that was cylindrically focused to 10mm. The applicator motion was step-wise rotational for imaging and therapy over a 360 degrees, or smaller, sector. The second transducer had 5-elements, each measuring 3.0x3.8 mm(2) for a total aperture of 3.0x20 mm(2). It operated at 5.6 MHz, was cylindrically focused to 14 mm, and was integrated with a servo-controlled oscillating probe designed for sector imaging and directive therapy in the liver. The last transducer was a 5-MHz, 64-element linear array designed for beam-formed imaging and therapy. The aperture was 3.0x18 mm(2) with a pitch of 0.280 mm. Characterization results included conversion efficiencies above 50%, pulse-echo bandwidths above 50%, surface intensities up to 30 W/cm(2), and axial imaging resolutions to 0.2 mm. The second transducer was evaluated in vivo using porcine liver, where coagulation necrosis was induced up to a depth of 20 mm in 120 s. B-mode and M-mode images displayed a hypoechoic region that agreed well with lesion depth observed by gross histology. These feasibility studies demonstrate that the dual-mode transducers had imaging performance that was sufficient to aid the guidance and monitoring of treatment, and could sustain high intensities to induce coagulation necrosis in vivo.

  8. Magnetic Resonance Imaging Findings of Intrahepatic Bile Duct Adenoma: A Report of 4 Cases.

    PubMed

    Liang, Wenjie; Xu, Shunliang

    2015-01-01

    Intrahepatic bile duct adenoma (BDA) is a rare type of benign hepatic lesions. In this study, 4 cases of BDA diagnosed from surgical resection pathology were examined. Their clinical and magnetic resonance imaging (MRI) data were retrospectively analyzed. The 4 cases (1 men and 3 women) were aged 21 to 55 years without obvious clinical symptoms. Three were identified through routine examination. Three had a history of chronic hepatitis B virus infection. Two cases were accompanied by hepatocellular carcinoma, and one had a higher level of α-fetoprotein. The MRI images of BDA all manifested as peripheral hepatic nodules with abnormal signals. The diameters of the lesions in the 4 cases were 7.7 to 17.0 mm. The MRI images showed slight hypointensity on T1WI and slight hyperintensity on T2WI in all cases, and they showed slight hyperintensity in 2 cases and hyperintensity in 2 cases on diffusion-weighted imaging. Dynamic contrast-enhanced MRI scans show hyperintensity in the arterial phase and slight hyperintensity in the late stage in 3 cases. The other case shows hyperintensity in the arterial and portal phases and isointensity at the delayed phase. During follow-up, 3 cases were recurrence-free. The other case was complicated by the reoccurrence of HCC. In general, BDA shows specific MRI characteristics, and peripheral hepatic nodules show slight hypointensity on T1WI and slight hyperintensity on T2WI. Dynamic contrast-enhanced MRI scans showed obvious enhancement in the arterial phase and continuous enhancement at the late stage.

  9. On the onset of secondary flow and unsteady solutions through a loosely coiled rectangular duct for large aspect ratio

    NASA Astrophysics Data System (ADS)

    Shaha, Poly Rani; Rudro, Sajal Kanti; Poddar, Nayan Kumar; Mondal, Rabindra Nath

    2016-07-01

    The study of flows through coiled ducts and channels has attracted considerable attention not only because of their ample applications in Chemical, Mechanical, Civil, Nuclear and Biomechanical engineering but also because of their ample applications in other areas, such as blood flow in the veins and arteries of human and other animals. In this paper, a numerical study is presented for the fully developed two-dimensional flow of viscous incompressible fluid through a loosely coiled rectangular duct of large aspect ratio. Numerical calculations are carried out by using a spectral method, and covering a wide range of the Dean number, Dn, for two types of curvatures of the duct. The main concern of the present study is to find out effects of curvature as well as formation of secondary vortices on unsteady solutions whether the unsteady flow is steady-state, periodic, multi-periodic or chaotic, if Dn is increased. Time evolution calculations as well as their phase spaces are performed with a view to study the non-linear behavior of the unsteady solutions, and it is found that the steady-state flow turns into chaotic flow through various flow instabilities, if Dn is increased no matter what the curvature is. It is found that the unsteady flow is a steady-state solution for small Dn's and oscillates periodically or non-periodically (chaotic) between two- and twelve-vortex solutions, if Dn is increased. It is also found that the chaotic solution is weak for small Dn's but strong as Dn becomes large. Axial flow distribution is also investigated and shown in contour plots.

  10. On the onset of secondary flow and unsteady solutions through a loosely coiled rectangular duct for large aspect ratio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaha, Poly Rani; Poddar, Nayan Kumar; Mondal, Rabindra Nath, E-mail: rnmondal71@yahoo.com

    The study of flows through coiled ducts and channels has attracted considerable attention not only because of their ample applications in Chemical, Mechanical, Civil, Nuclear and Biomechanical engineering but also because of their ample applications in other areas, such as blood flow in the veins and arteries of human and other animals. In this paper, a numerical study is presented for the fully developed two-dimensional flow of viscous incompressible fluid through a loosely coiled rectangular duct of large aspect ratio. Numerical calculations are carried out by using a spectral method, and covering a wide range of the Dean number, Dn,more » for two types of curvatures of the duct. The main concern of the present study is to find out effects of curvature as well as formation of secondary vortices on unsteady solutions whether the unsteady flow is steady-state, periodic, multi-periodic or chaotic, if Dn is increased. Time evolution calculations as well as their phase spaces are performed with a view to study the non-linear behavior of the unsteady solutions, and it is found that the steady-state flow turns into chaotic flow through various flow instabilities, if Dn is increased no matter what the curvature is. It is found that the unsteady flow is a steady-state solution for small Dn’s and oscillates periodically or non-periodically (chaotic) between two- and twelve-vortex solutions, if Dn is increased. It is also found that the chaotic solution is weak for small Dn’s but strong as Dn becomes large. Axial flow distribution is also investigated and shown in contour plots.« less

  11. Acoustic propagation in curved ducts with extended reacting wall treatment

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation was employed to study the attenuation of acoustic waves propagating in two-dimensional S-curved ducts with absorbing walls without a mean flow. The reflection and transmission at the entrance and the exit of a curved duct were determined by coupling the finite-element solutions in the curved duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, the effects of duct length, curvature (duct offset) and absorber thickness were examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. A means of reducing the number of elements in the absorber region was also presented. In addition, for a curved duct, power attenuation contours were examined to determine conditions for maximum acoustic power absorption. Again, wall curvature was found to significantly effect the optimization process.

  12. Successful treatment of suspected organizing pneumonia in a patient without typical imaging and pathological characteristic: A case report.

    PubMed

    Ailing, Liu; Ning, Xu; Tao, Qu; Aijun, Li

    2017-01-01

    Organizing pneumonia (OP) is a clinicopathological entity characterized by granulation tissue plugs in the lumen of small airways, alveolar ducts, and alveoli. Diagnosis of OP needs the combination of clinical features, imaging and pathology. But it occurs often that there are no typical pathological features to support the diagnosis, which poses a challenge for clinicians' diagnosis and treatment. We diagnosed a case of OP without typical imaging and pathological characteristic and treated successfully. Finally we confirmed the pathological diagnosis. Not every OP case is supported by pathological evidence and typical imaging changes. It is important for us to judge and decide the diagnosis according to clinical experience.

  13. Electromagnetic propagation in PEC and absorbing curved S-ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1988-01-01

    A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.

  14. Transition duct assembly with modified trailing edge in turbine system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMahan, Kevin Weston; Schott, Carl Gerard; Ingram, Clint Luigie

    2016-10-04

    Transition duct assemblies for turbine systems and turbomachines are provided. In one embodiment, a transition duct assembly includes a plurality of transition ducts disposed in a generally annular array and comprising a first transition duct and a second transition duct. Each of the plurality of transition ducts includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of each transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct assembly further includes anmore » aerodynamic structure defined by the passages of the first transition duct and the second transition duct. The aerodynamic structure includes a pressure side, a suction side, and a trailing edge, the trailing edge having a modified aerodynamic contour.« less

  15. Combustor assembly in a gas turbine engine

    DOEpatents

    Wiebe, David J; Fox, Timothy A

    2013-02-19

    A combustor assembly in a gas turbine engine. The combustor assembly includes a combustor device coupled to a main engine casing, a first fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner disposed radially inwardly from the flow sleeve. The first fuel injection system provides fuel that is ignited with the pressurized air creating first working gases. The intermediate duct is disposed between the liner and the transition duct and defines a path for the first working gases to flow from the liner to the transition duct. An intermediate duct inlet portion is associated with a liner outlet and allows movement between the intermediate duct and the liner. An intermediate duct outlet portion is associated with a transition duct inlet section and allows movement between the intermediate duct and the transition duct.

  16. Investigation of Pneumatic Inlet and Diffuser Blowing on a Ducted Fan Propulsor in Static Thrust Operation

    NASA Technical Reports Server (NTRS)

    Kondor, Shayne; Englar, Robert J.; Lee, Warren J.

    2003-01-01

    Tilting ducted fans present a solution for the lifting and forward flight propulsion requirements of VTOL aircraft. However, the geometry of the duct enshrouding the propeller has great a effect on the efficiency of the fan in various flight modes. Shroud geometry controls the velocity and pressure at the face of the fan, while maintaining a finite loading out at the tips of the fan blades. A duct tailored for most efficient generation of static lifting thrust will generally suffer from performance deficiencies in forward flight. The converse is true as well, leaving the designer with a difficult trade affecting the overall performance and sizing of the aircraft. Ideally, the shroud of a vertical lifting fan features a generous bell mouth inlet promoting acceleration of flow into the face of the fan, and terminating in a converging nozzle at the exit. Flow entering the inlet is accelerated into the fan by the circulation about the shroud, resulting in an overall increase in thrust compared to an open propeller operating under the same conditions . The accelerating shroud design is often employed in lifting ducted fans to benefit from the thrust augmentation; however, such shroud designs produce significant drag penalties in axial flight, thus are unsuitable for efficient forward flight applications. Decelerating, or diffusing, duct designs are employed for higher speed forward flight configurations. The lower circulation on the shroud tends to decelerate the flow into the face of the fan, which is detrimental to static thrust development; however, net thrust is developed on the shroud while the benefits of finite blade loading are retained. With judicious shroud design for intended flight speeds, a net increase in efficiency can be obtained over an open propeller. In this experiment, conducted under contract to NASA LaRC (contract NAG-1-02093) circulation control is being applied to a mildly diffusing shroud design, intended for improved forward flight performance, to generate circulation in the sense of an accelerating duct design. The intent is to improve static thrust performance of a ducted fan tailored for high speed axial flight, while at the same time significantly reduce the pressure signature on the ground plane. Circulation control on the fan shroud is achieved by the Coanda effect.

  17. Adult bile duct strictures: differentiating benign biliary stenosis from cholangiocarcinoma.

    PubMed

    Nguyen Canh, Hiep; Harada, Kenichi

    2016-12-01

    Biliary epithelial cells preferentially respond to various insults under chronic pathological conditions leading to reactively atypical changes, hyperplasia, or the development of biliary neoplasms (such as biliary intraepithelial neoplasia, intraductal papillary neoplasm of the bile duct, and cholangiocarcinoma). Moreover, benign biliary strictures can be caused by a variety of disorders (such as IgG4-related sclerosing cholangitis, eosinophilic cholangitis, and follicular cholangitis) and often mimic malignancies, despite their benign nature. In addition, primary sclerosing cholangitis is a well-characterized precursor lesion of cholangiocarcinoma and many other chronic inflammatory disorders increase the risk of malignancies. Because of these factors and the changes in biliary epithelial cells, biliary strictures frequently pose a diagnostic challenge. Although the ability to differentiate neoplastic from non-neoplastic biliary strictures has markedly progressed with the advance in radiological modalities, brush cytology and bile duct biopsy examination remains effective. However, no single modality is adequate to diagnose benign biliary strictures because of the low sensitivity. Therefore, understanding the underlying causes by compiling the entire clinical, laboratory, and imaging data; considering the under-recognized causes; and collaborating between experts in various fields including cytopathologists with multiple approaches is necessary to achieve an accurate diagnosis.

  18. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy.

    PubMed

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T 4 ) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts.

  19. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy

    PubMed Central

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Abstract. Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T4) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts. PMID:29026274

  20. Effects of preferential concentration on direct radiation transmission in a turbulent duct flow

    NASA Astrophysics Data System (ADS)

    Villafane, Laura; Banko, Andrew; Kim, Ji Hoon; Elkins, Chris; Eaton, John

    2017-11-01

    Inertial particles in turbulent flows preferentially concentrate, giving rise to spatial and temporal fluctuations of particle number density that affect radiation transmission through the medium. Positive particle correlations enhance direct transmission when compared to the exponential attenuation predicted by the Beer's Law for randomly distributed particles. In the context of a particle based solar receiver, this work studies the effects of preferential concentration and optical depth on direct transmission through a particle laden turbulent duct flow. Time resolved measurements of transmission through the mixture were performed for various particle loadings and Reynolds numbers, thus varying particle correlation lengths, optical depth and concentration fluctuations. These measurements were made using a photodiode to record the transmission of a collimated laser beam along the wall bisector of the duct. A synchronized high-speed camera provided particle positions along most of the beam path. Average and fluctuating radiation transmission results are compared to predictions derived from the imaged number density fields and to simplified analytical models. Simplified models are able to capture the correct trends with varying loading and preferential concentration. This work is funded by the Department of Energy's National Nuclear Security Administration, Grant #DE-NA0002373-1.

  1. Unconventional Management of Chyloascites After Laparoscopic Nissen Fundoplication

    PubMed Central

    Ospina, Karen A.; Lee, Earl H.; Rehring, Scott R.

    2012-01-01

    Background & Objectives: Chyloascites is a rare complication that can result from abdominal trauma, neoplasm, inflammatory conditions, or various abdominal surgeries. Few cases have been described secondary to iatrogenic injury from laparoscopic Nissen fundoplication. We describe a case in which this surgery resulted in chyloascites that was successfully treated by lymphatic glue embolization. Methods: A 37-year-old male presented with signs and symptoms consistent with chronic reflux disease. He underwent an uneventful laparoscopic Nissen fundoplication. Two weeks postoperatively, he was admitted for dehydration. During his admission, he began to develop a persistent cough, shortness of breath, and abdominal distention. Imaging and fluid analysis from thoracocentesis and paracentesis were consistent with chyle leakage. Despite nonoperative measures, the patient's presentation persisted. Results: Thoracic duct ligation was performed without success. Bipedal lymphangiography identified an extensive leak revealing a severely lacerated thoracic duct spilling contrast freely into the abdomen and no contrast entering the thoracic duct in the chest. The site of injury was successfully sealed off with percutaneous glue embolization through lymph channels. Conclusion: Chyloascites is a rare complication of laparoscopic Nissen fundoplication. When not successful with conservative measures, lymphatic glue embolization can provide effective treatment. PMID:23477184

  2. Oxygen transport in a cross section of the rat inner medulla: Impact of heterogeneous distribution of nephrons and vessels

    PubMed Central

    Fry, Brendan C.; Layton, Anita T.

    2014-01-01

    We have developed a highly detailed mathematical model of oxygen transport in a cross section of the upper inner medulla of the rat kidney. The model is used to study the impact of the structured organization of nephrons and vessels revealed in anatomic studies, in which descending vasa recta are found to lie distant from clusters of collecting ducts. Specifically, we formulated a two-dimensional oxygen transport model, in which the positions and physical dimensions of renal tubules and vessels are based on an image obtained by immunochemical techniques (Pannabecker and Dantzler, Am J Physiol Renal Physiol, 2006). The model represents oxygen diffusion through interstitium and other renal structures, oxygen consumption by the Na+/K+-ATPase activities of the collecting ducts, and basal metabolic consumption. Model simulations yield marked variations in interstitial PO2, which can be attributed, in large part, to the heterogeneities in the position and physical dimensions of the collecting ducts. Further, results of a sensitivity study suggest that medullary oxygenation is highly sensitive to medullary blood flow, and that, at high active consumption rates, localized patches of tissue may be vulnerable to hypoxic injury. PMID:25260928

  3. Visualizing surface area and volumes of lumens in 3 dimensions using images from histological sections

    USDA-ARS?s Scientific Manuscript database

    Visualizing areas of tissue that are occupied by air or liquid can provide a unique perspective on the relationships between various spaces within the tissue. The portal tracts of liver tissue are an example of such a space since the liver contains several vessels and ducts in various patterns of i...

  4. Hepatobiliary fascioliasis: a case with unusual radiological features.

    PubMed

    Yeşildağ, Ahmet; Senol, Altuğ; Köroğlu, Mert; Koçkar, Cem; Oyar, Orhan; Işler, Mehmet

    2010-12-01

    We report a case of hepatobiliary fascioliasis presenting with unusual radiological findings that have not been reported previously. Imaging studies revealed hepatic cystic pouches communicating with intrahepatic bile ducts. Snail-like, oval shaped and conglomerated echogenic particles with no acoustic shadowing, suggesting F. hepatica, were detected in these cystic pouches. In addition, secondary sclerosing cholangitis developed after fascioliasis.

  5. Investigation of a Translatable Animal Model in Order to Understand the Etiology of Heterotopic Ossification

    DTIC Science & Technology

    2017-09-01

    dB levels that were made by the AID without attenuation, we performed this testing in a cinderblock-based room with metal ducting, cement floors and... steel -framed ceilings (Figure 7). 8 Figure 7: Image of a corner of the cinderblock room in which testing has been performed. To measure

  6. Turbofan aft duct suppressor study program listing and user's guide

    NASA Technical Reports Server (NTRS)

    Joshi, M. C.; Kraft, R. E.

    1983-01-01

    A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.

  7. Measuring Thermal Conductivity of a Small Insulation Sample

    NASA Technical Reports Server (NTRS)

    Miller, Robert A.; Kuczmarski, Maria A.

    2009-01-01

    A multiple-throat venturi system has been invented for measuring laminar flow of air or other gas at low speed (1 to 30 cm/s) in a duct while preserving the laminar nature of the flow and keeping the velocity profile across the duct as nearly flat as possible. While means for measuring flows at higher speeds are well established, heretofore, there have been no reliable means for making consistent, accurate measurements in this speed range. In the original application for which this system was invented, the duct leads into the test section of a low-speed wind tunnel wherein uniform, low-speed, laminar flow is required for scientific experiments. The system could also be used to monitor a slow flow of gas in an industrial process like chemical vapor deposition. In the original application, the multiple- throat venturi system is mounted at the inlet end of the duct having a rectangular cross section of 19 by 14 cm, just upstream of an assembly of inlet screens and flow straighteners that help to suppress undesired flow fluctuations (see Figure 1). The basic venturi measurement principle is well established: One measures the difference in pressure between (1) a point just outside the inlet, where the pressure is highest and the kinetic energy lowest; and (2) the narrowest part (the throat) of the venturi passage, where the kinetic energy is highest and the pressure is lowest. Then by use of Bernoulli s equation for the relationship between pressure and kinetic energy, the volumetric flow speed in the duct can be calculated from the pressure difference and the inlet and throat widths. The design of this system represents a compromise among length, pressure recovery, uniformity of flow, and complexity of assembly. Traditionally, venturis are used to measure faster flows in narrower cross sections, with longer upstream and downstream passages to maintain accuracy. The dimensions of the passages of the present venturi system are sized to provide a readily measurable pressure drop. Multiple throats are used to minimize the length needed to recover internal energy and enable the velocity profile to recover to near flatness.

  8. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...

  9. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts and air duct systems. 25.1103 Section 25.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Induction System § 25.1103 Induction system ducts and air duct...

  10. Duct Joining System

    DOEpatents

    Proctor, John P.

    2001-02-27

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  11. Duct joining system

    DOEpatents

    Proctor, John P.; deKieffer, Robert C.

    2001-01-01

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  12. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  13. Experimental study of noise sources and acoustic propagation in a turbofan model

    NASA Astrophysics Data System (ADS)

    Lewy, S.; Canard-Caruana, S.; Julliard, J.

    1990-10-01

    Experimental studies of the acoustic radiation of subsonic fans mainly due to blade and vane presure fluctuations were performed in the SNECMA 5C2 compressor anechoic facility. A brief description of the test rig is presented noting that the CA5 turbojet engine model fan has a diameter of 47 cm, 48 blades, and a nominal rotation speed of 12,600 rpm. The two chief experiments discussed are the measurement of blade and vane pressure fluctuations by thin-film transducers and the spinning mode analysis of the sound field propagating in the intake duct. Several examples of applications are discussed, and it is shown that an inflow control device, as expected, reduces the aerodynamic disturbances by about 10 dB. Rotor-stator interaction tones are determined by the modal analysis, and it is found that a duct lining with a length of one duct radius could give an insertion loss up to 20 dB in flight.

  14. Calculation of flow about posts and powerhead model. [space shuttle main engine

    NASA Technical Reports Server (NTRS)

    Anderson, P. G.; Farmer, R. C.

    1985-01-01

    A three dimensional analysis of the non-uniform flow around the liquid oxygen (LOX) posts in the Space Shuttle Main Engine (SSME) powerhead was performed to determine possible factors contributing to the failure of the posts. Also performed was three dimensional numerical fluid flow analysis of the high pressure fuel turbopump (HPFTP) exhaust system, consisting of the turnaround duct (TAD), two-duct hot gas manifold (HGM), and the Version B transfer ducts. The analysis was conducted in the following manner: (1) modeling the flow around a single and small clusters (2 to 10) of posts; (2) modeling the velocity field in the cross plane; and (3) modeling the entire flow region with a three dimensional network type model. Shear stress functions which will permit viscous analysis without requiring excessive numbers of computational grid points were developed. These wall functions, laminar and turbulent, have been compared to standard Blasius solutions and are directly applicable to the cylinder in cross flow class of problems to which the LOX post problem belongs.

  15. Secretin stimulates HCO3(-) and acetate efflux but not Na+/HCO3(-) uptake in rat pancreatic ducts.

    PubMed

    Novak, I; Christoffersen, B C

    2001-03-01

    Pancreatic ducts secrete HCO3(-), but transport mechanisms are unresolved and possibly vary between species. Our aim was to study the intracellular pH (pHi) regulation and thus H+/HCO3- transport in rat pancreatic ducts. Of particular interest was the Na+/HCO3(-) cotransporter, thought to be important in HCO3(-) -transporting epithelia. pHi was measured with BCECF in freshly isolated intralobular ducts. A reduction in extracellular Na+ concentration or application of HOE 694 (1 microM) decreased pHi by 0.1 to 0.6 pH units, demonstrating Na+/H+ exchanger activity. A reduction in extracellular Cl- concentration or addition of H2DIDS (10 microM) increased pHi by 0.1 to 0.5 pH units, demonstrating Cl-/ HCO(3)- (OH ) exchanger activity. In experimental acidosis, extracellular HCO3(-)/CO2 buffer did not increase the rate of pHi recovery, indicating that provision of HCO3(-) by the Na+/HCO3(-) cotransporter was not apparent. Most importantly, Na+/HCO3(-) cotransport was not stimulated by secretin (1 nM). In contrast, in experimental alkalosis the pHi recovery was increased in HCO3(-)/CO2 buffer, possibly due to Na+/HCO3(-) cotransport in the efflux mode. Secretin (1 nM) and carbachol (1 microM) stimulated HCO3(-) efflux, which can account for the observed HCO3(-) concentrations in rat pancreatic juice. Acetate and HCO3(-) buffers were handled similarly, indicating similar transport mechanisms in pancreatic ducts.

  16. [Hepaticojejunostomy after pancreatic head resection - technical aspects for reconstruction of small and fragile bile ducts with T-tube drainage].

    PubMed

    Herzog, T; Belyaev, O; Uhl, W; Seelig, M H; Chromik, A

    2012-12-01

    After pancreatic head resection the reconstruction of small and fragile bile ducts is technically demanding, resulting in more postoperative bile leaks. One option for the reconstruction is the placement of a T-tube drainage at the site of the anastomosis. Standard reconstruction after pancreatic head resection was an end-to-side hepaticojejunostomy with PDS 5.0, 15-25 cm distally from the pancreaticojejunostomy. For patients with a small bile duct diameter (≤ 5 mm) or a fragile bile duct wall the reconstruction was performed with PDS 6.0 and a T-tube drainage at the side of the anastomosis. The reconstruction with a T-tube drainage at the site of the anastomosis is technically easy to perform and offers the opportunity for immediate visualisation of the anastomosis in the postoperative period by application of water soluble contrast medium. If a bile leak occurs, biliary deviation through the T-tube drainage can enable a conservative management without revisional laparotomy in selected patients. Whether or not a conservative management of postoperative bile leaks will lead to more bile duct strictures is a subject for further investigations. A T-tube drainage at the site of the anastomosis can probably not prevent postoperative bile leaks from a difficult hepaticojejunostomy, but in selected patients it offers the opportunity for a conservative management resulting in less re-operations. Therefore we recommend the augmentation of a difficult hepaticojejunostomy with a T-tube drainage. Georg Thieme Verlag KG Stuttgart · New York.

  17. A Model for Shear Layer Effects on Engine Noise Radiation

    NASA Technical Reports Server (NTRS)

    Nark, Douglas M.; Farassat, F.; Pope, D. Stuart; Vatsa, V.

    2004-01-01

    Prediction of aircraft engine noise is an important aspect of addressing the issues of community noise and cabin noise control. The development of physics based methodologies for performing such predictions has been a focus of Computational Aeroacoustics (CAA). A recent example of code development in this area is the ducted fan noise propagation and radiation code CDUCT-LaRC. Included within the code is a duct radiation model that is based on the solution of FfowcsWilliams-Hawkings (FW-H) equation with a penetrable data surface. Testing of this equation for many acoustic problems has shown it to provide generally better results than the Kirchhoff formula for moving surfaces. Currently, the data surface is taken to be the inlet or exhaust plane for inlet or aft-fan cases, respectively. While this provides reasonable results in many situations, these choices of data surface location lead to a few limitations. For example, the shear layer between the bypass ow and external stream can refract the sound waves radiated to the far field. Radiation results can be improved by including this effect, as well as the rejection of the sound in the bypass region from the solid surface external to the bypass duct surrounding the core ow. This work describes the implementation, and possible approximation, of a shear layer boundary condition within CDUCT-LaRC. An example application also illustrates the improvements that this extension offers for predicting noise radiation from complex inlet and bypass duct geometries, thereby providing a means to evaluate external treatments in the vicinity of the bypass duct exhaust plane.

  18. Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators

    NASA Astrophysics Data System (ADS)

    Deng, Lei; Zhou, Ning; Chen, Yi-shui; Tu, Yu

    2017-11-01

    Shielding body of the high-energy medical electron accelerators is always penetrated by ducts, which would influence the shielding capability of local barrier. In order to quantitatively analyze the duct's impact on shielding of the photoneutron from 15 MV accelerators, the ambient dose equivalent rate and energy spectrum at the center of a typical duct and the external mouth of duct were calculated based on MCNP program for the first time. The results demonstrate that leakage neutrons at the external mouth of duct are mainly thermal neutron, and its dose rate is decreased with the increase of the intersection angle between duct and wall as well as the reduction of duct diameter. When a duct in a diameter no more than 30 cm penetrates the wall unidirectionally and the inclined Angle (θ) is 60°, neutron dose rate at the external mouth of duct could meet the requirements of protection. At last, according to the calculation results, some suggestions are proposed for the shielding design of ducts in walls.

  19. Anomalous pancreatico-biliary ductal union with cystic dilatation of the bile duct.

    PubMed

    Richer, J P; Faure, J P; Morichau-Beauchant, M; Dugue, T; Maillot, N; Kamina, P; Carretier, M

    1998-01-01

    We report, in an adult, an asymptomatic association between cystic dilation of the bile duct (type IV A in Todani's classification) and anomalous pancreatico-biliary ductal union (APBD) with stones in a long common channel. In APBD, the connection between the common bile duct and the main pancreatic duct is located outside the duodenal wall andis therefore not under the influence of the sphincter of Boyden. An abnormally long common channel is in excess of 15 mm. Two types of convergence anomalies are defined according to whether the bile duct opens into the main pancreatic duct (BP) or the main pancreatic duct into the bile duct (PB). In APBD, there is probably a reverse pressure gradient between the bile and pancreatic ducts, with regurgitation of pancreatic juice into the bile duct, repeated attacks of cholangitis, stenosis and cystic dilatation. A long common channel is associated with a higher incidence of carcinoma of the gall bladder of the bile duct.

  20. Xanthogranulomatous pancreatitis: A review of the imaging characteristics of this rare and often misdiagnosed lesion of the pancreas.

    PubMed

    Becker-Weidman, David; Floré, Bernard; Mortelé, Koenraad J

    Xanthogranulomatous pancreatitis (XGP) is an extremely rare cause of a cystic pancreatic mass. The pathophysiology of this process is not entirely clear but likely results from a combination of duct obstruction, infection, and repeated hemorrhage. It is difficult to differentiate this inflammatory lesion from a cystic neoplasm and, therefore, in the majority of cases XGP is misdiagnosed as a neoplasm on preoperative imaging. In this report, we describe a case of XGP, the imaging characteristics of XGP, and a differential diagnosis for a cystic pancreatic lesion. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Congenital cystic neck masses: embryology and imaging appearances, with clinicopathological correlation.

    PubMed

    Gaddikeri, Santhosh; Vattoth, Surjith; Gaddikeri, Ramya S; Stuart, Royal; Harrison, Keith; Young, Daniel; Bhargava, Puneet

    2014-01-01

    Congenital cystic masses of the neck are uncommon and can present in any age group. Diagnosis of these lesions can be sometimes challenging. Many of these have characteristic locations and imaging findings. The most common of all congenital cystic neck masses is the thyroglossal duct cyst. The other congenital cystic neck masses are branchial cleft cyst, cystic hygroma (lymphangioma), cervical thymic and bronchogenic cysts, and the floor of the mouth lesions including dermoid and epidermoid cysts. In this review, we illustrate the common congenital cystic neck masses including embryology, clinical findings, imaging features, and histopathological findings. Copyright © 2014 Elsevier, Inc. All rights reserved.

  2. A qualitative and quantitative laser-based computer-aided flow visualization method. M.S. Thesis, 1992 Final Report

    NASA Technical Reports Server (NTRS)

    Canacci, Victor A.; Braun, M. Jack

    1994-01-01

    The experimental approach presented here offers a nonintrusive, qualitative and quantitative evaluation of full field flow patterns applicable in various geometries in a variety of fluids. This Full Flow Field Tracking (FFFT) Particle Image Velocimetry (PIV) technique, by means of particle tracers illuminated by a laser light sheet, offers an alternative to Laser Doppler Velocimetry (LDV), and intrusive systems such as Hot Wire/Film Anemometry. The method makes obtainable the flow patterns, and allows quantitative determination of the velocities, accelerations, and mass flows of an entire flow field. The method uses a computer based digitizing system attached through an imaging board to a low luminosity camera. A customized optical train allows the system to become a long distance microscope (LDM), allowing magnifications of areas of interest ranging up to 100 times. Presented in addition to the method itself, are studies in which the flow patterns and velocities were observed and evaluated in three distinct geometries, with three different working fluids. The first study involved pressure and flow analysis of a brush seal in oil. The next application involved studying the velocity and flow patterns in a cowl lip cooling passage of an air breathing aircraft engine using water as the working fluid. Finally, the method was extended to a study in air to examine the flows in a staggered pin arrangement located on one side of a branched duct.

  3. CFL3D: Its History and Some Recent Applications

    NASA Technical Reports Server (NTRS)

    Rumsey, C. L.; Biedron, R. T.; Thomas, J. L.

    1997-01-01

    The history of the Computational Fluids Laboratory -3D (CFL3D) Navier-Stokes computer code is discussed and a comprehensive reference list is given. Three recent advanced applications are presented (1) Wing with partial-spanflap, (2) F/A-18 with forebody control strake, and (3) Noise predictions for an advanced ducted propeller turbomachinery flow.

  4. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  5. Active noise control: A tutorial for HVAC designers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelin, L.J.

    1997-08-01

    This article will identify the capabilities and limitations of ANC in its application to HVAC noise control. ANC can be used in ducted HVAC systems to cancel ductborne, low-frequency fan noise by injecting sound waves of equal amplitude and opposite phase into an air duct, as close as possible to the source of the unwanted noise. Destructive interference of the fan noise and injected noise results in sound cancellation. The noise problems that it solves are typically described as rumble, roar or throb, all of which are difficult to address using traditional noise control methods. This article will also contrastmore » the use of active against passive noise control techniques. The main differences between the two noise control measures are acoustic performance, energy consumption, and design flexibility. The article will first present the fundamentals and basic physics of ANC. The application to real HVAC systems will follow.« less

  6. An integral turbulent kinetic energy analysis of free shear flows

    NASA Technical Reports Server (NTRS)

    Peters, C. E.; Phares, W. J.

    1973-01-01

    Mixing of coaxial streams is analyzed by application of integral techniques. An integrated turbulent kinetic energy (TKE) equation is solved simultaneously with the integral equations for the mean flow. Normalized TKE profile shapes are obtained from incompressible jet and shear layer experiments and are assumed to be applicable to all free turbulent flows. The shear stress at the midpoint of the mixing zone is assumed to be directly proportional to the local TKE, and dissipation is treated with a generalization of the model developed for isotropic turbulence. Although the analysis was developed for ducted flows, constant-pressure flows were approximated with the duct much larger than the jet. The axisymmetric flows under consideration were predicted with reasonable accuracy. Fairly good results were also obtained for the fully developed two-dimensional shear layers, which were computed as thin layers at the boundary of a large circular jet.

  7. Increased Na+/H+ exchanger activity on the apical surface of a cilium-deficient cortical collecting duct principal cell model of polycystic kidney disease

    PubMed Central

    Olteanu, Dragos; Liu, Xiaofen; Liu, Wen; Roper, Venus C.; Sharma, Neeraj; Yoder, Bradley K.; Satlin, Lisa M.; Schwiebert, Erik M.

    2012-01-01

    Pathophysiological anomalies in autosomal dominant and recessive forms of polycystic kidney disease (PKD) may derive from impaired function/formation of the apical central monocilium of ductal epithelia such as that seen in the Oak Ridge polycystic kidney or orpk (Ift88Tg737Rpw) mouse and its immortalized cell models for the renal collecting duct. According to a previous study, Na/H exchanger (NHE) activity may contribute to hyperabsorptive Na+ movement in cilium-deficient (“mutant”) cortical collecting duct principal cell monolayers derived from the orpk mice compared with cilium-competent (“rescued”) monolayers. To examine NHE activity, we measured intracellular pH (pHi) by fluorescence imaging with the pH-sensitive dye BCECF, and used a custom-designed perfusion chamber to control the apical and basolateral solutions independently. Both mutant and rescued monolayers exhibited basolateral Na+-dependent acid-base transporter activity in the nominal absence of CO2/HCO3−. However, only the mutant cells displayed appreciable apical Na+-induced pHi recoveries from NH4+ prepulse-induced acid loads. Similar results were obtained with isolated, perfused collecting ducts from orpk vs. wild-type mice. The pHi dependence of basolateral cariporide/HOE-694-sensitive NHE activity under our experimental conditions was similar in both mutant and rescued cells, and 3.5- to 4.5-fold greater than apical HOE-sensitive NHE activity in the mutant cells (pHi 6.23–6.68). Increased apical NHE activity correlated with increased apical NHE1 expression in the mutant cells, and increased apical localization in collecting ducts of kidney sections from orpk vs. control mice. A kidney-specific conditional cilium-knockout mouse produced a more acidic urine compared with wild-type littermates and became alkalotic by 28 days of age. This study provides the first description of altered NHE activity, and an associated acid-base anomaly in any form of PKD. PMID:22301060

  8. Digital, single-operator cholangiopancreatoscopy in the diagnosis and management of pancreatobiliary disorders: a multicenter clinical experience (with video).

    PubMed

    Navaneethan, Udayakumar; Hasan, Muhammad K; Kommaraju, Kiran; Zhu, Xiang; Hebert-Magee, Shantel; Hawes, Robert H; Vargo, John J; Varadarajulu, Shyam; Parsi, Mansour A

    2016-10-01

    Digital cholangioscopes provide higher-resolution imaging of the pancreatobiliary tract compared with fiberoptic instruments. The role of a new, digital, single-operator cholangiopancreatoscopy (SOC) system for diagnosis and treatment of pancreatobiliary disorders in clinical practice is not known. We performed a multicenter, observational study of 105 consecutive patients with suspected pancreatobiliary disorders. The main outcome measures were (1) sensitivity and specificity of SOC visual appearance and biopsies in the diagnosis of indeterminate biliary strictures and (2) achieving complete duct clearance in patients with biliary or pancreatic duct stones. A total of 98 cholangioscopy and 7 pancreatoscopy procedures were performed in 105 patients. Superior views of the ductal lumen and mucosa were obtained in all 44 patients with indeterminate biliary strictures. Among the 44 patients who underwent SOC-guided biopsies, the specimen was adequate for histologic evaluation in 43 patients (97.7%). The sensitivity and specificity of SOC visual impression for diagnosis of malignancy was 90% (95% confidence interval [CI], 69.9%-97.2%) and 95.8% (95% CI, 79.8%-99.3%), respectively. The sensitivity and specificity of SOC-guided biopsies for diagnosis of malignancy was 85% (95% CI, 64.0%-94.8%) and 100% (95% CI, 86.2%-100%). In patients with biliary or pancreatic duct stones (N = 36), complete duct clearance with stone removal in 1 session was accomplished in 86.1% of patients (31/36). Three patients (2.9%) experienced SOC-related adverse events that included cholangitis in 2 patients and postprocedure pancreatitis in 1 patient. SOC has become an integral part of the ERCP armamentarium and has high accuracy in the evaluation of indeterminate biliary strictures. Complete stone clearance was achieved in all but 1 patient with challenging biliary or pancreatic duct stones. ( NCT01815619.). Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. Pancreatic trauma

    PubMed Central

    Bhattacharya, S

    2013-01-01

    Introduction Pancreatic trauma occurs in approximately 4% of all patients sustaining abdominal injuries. The pancreas has an intimate relationship with the major upper abdominal vessels, and there is significant morbidity and mortality associated with severe pancreatic injury. Immediate resuscitation and investigations are essential to delineate the nature of the injury, and to plan further management. If main pancreatic duct injuries are identified, specialised input from a tertiary hepatopancreaticobiliary (HPB) team is advised. Methods A comprehensive online literature search was performed using PubMed. Relevant articles from international journals were selected. The search terms used were: ‘pancreatic trauma’, ‘pancreatic duct injury’, ‘radiology AND pancreas injury’, ‘diagnosis of pancreatic trauma’, and ‘management AND surgery’. Articles that were not published in English were excluded. All articles used were selected on relevance to this review and read by both authors. Results Pancreatic trauma is rare and associated with injury to other upper abdominal viscera. Patients present with non-specific abdominal findings and serum amylase is of little use in diagnosis. Computed tomography is effective in diagnosing pancreatic injury but not duct disruption, which is most easily seen on endoscopic retrograde cholangiopancreaticography or operative pancreatography. If pancreatic injury is suspected, inspection of the entire pancreas and duodenum is required to ensure full evaluation at laparotomy. The operative management of pancreatic injury depends on the grade of injury found at laparotomy. The most important prognostic factor is main duct disruption and, if found, reconstructive options should be determined by an experienced HPB surgeon. Conclusions The diagnosis of pancreatic trauma requires a high index of suspicion and detailed imaging studies. Grading pancreatic injury is important to guide operative management. The most important prognostic factor is pancreatic duct disruption and in these cases, experienced HPB surgeons should be involved. Complications following pancreatic trauma are common and the majority can be managed without further surgery. PMID:23676806

  10. Predictive value of dual-energy spectral computed tomographic imaging on the histological origin of carcinomas in the ampullary region.

    PubMed

    Wei, Wei; Yu, Yongqiang; Lv, Weifu; Deng, Kexue; Yuan, Lei; Zhao, Yingming

    2014-08-01

    To investigate the value of dual-energy spectral computed tomographic imaging (DESCT) to predict the origin of carcinomas in the ampullary region. Fifty-seven patients with suspected ampullary region carcinomas underwent DESCT prior to biopsy or surgery. Among those patients, 30 were pancreatic adenocarcinomas, 11 were biliary adenocarcinomas, 16 were adenocarcinomas of the ampulla diagnosed by biopsy and/or pathological examination before or after surgical operation. We compared the CT spectral imaging features among the adenocarcinomas with the above-mentioned three different origins. Iodine concentration thresholds of 16.36, 21.86, and 21.86 mg/mL yielded a sensitivity and specificity of 100% for distinguishing between common bile duct adenocarcinomas and pancreatic adenocarcinomas in the arterial phase (AP), portal venous phase (PP), and delayed phase (DP), respectively. Thresholds of 16.70, 24.33, and 26.43 mg/mL yielded a sensitivity and specificity of 100% for distinguishing between common bile duct adenocarcinomas and ampullary adenocarcinomas in the AP, PP, and DP, respectively. Iodine concentration thresholds of 16.66 and 17.78 mg/mL yielded a sensitivity and specificity of 100% for distinguishing between ampullary adenocarcinomas and pancreatic adenocarcinomas in the PP and DP, respectively. DESCT with multiple parameters can provide useful diagnostic information and may be used to predict the histological origin of carcinomas in the ampullary region.

  11. Passively-coupled, low-coherence interferometric duct profiling with an astigmatism-corrected conical mirror.

    PubMed

    Ford, Helen D; Tatam, Ralph P

    2017-04-17

    Duct-profiling in test samples up to 25 mm in diameter has been demonstrated using a passive, low-coherence probe head with a depth resolution of 7.8 μm, incorporating an optical-fibre-linked conical mirror addressed by a custom-built array of single-mode fibres. Zemax modelling, and experimental assessment of instrument performance, show that degradation of focus, resulting from astigmatism introduced by the conical mirror, is mitigated by the introduction of a novel lens element. This enables a good beam focus to be achieved at distances of tens of millimetres from the cone axis, not achievable when the cone is used alone. Incorporation of the additional lens element is shown to provide a four-fold improvement in lateral imaging resolution, when compared with reflection from the conical mirror alone.

  12. Apparatus for supplying conditioned air at a substantially constant temperature and humidity

    NASA Technical Reports Server (NTRS)

    Obler, H. D. (Inventor)

    1980-01-01

    The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.

  13. Light microscopical structure of the excurrent ducts and distribution of spermatozoa in the Australian rodents Pseudomys australis and Notomys alexis.

    PubMed Central

    Peirce, E J; Breed, W G

    1989-01-01

    The light microscopical structure of the male excurrent ducts and the distribution of spermatozoa were examined in two species of Australian rodents, the plains rat, Pseudomys australis, and the hopping mouse, Notomys alexis. In plains rats the microstructure of the ductus epididymidis and ductus deferens was similar to that of the common laboratory rodents, with the majority of the spermatozoa being found in the cauda epididymides. By contrast, in the hopping mouse, the structure of the cauda epididymidis differed significantly as the height of the epithelium and stereocilia did not decrease from the distal caput to the cauda region, and luminal diameter did not increase markedly along its length. In addition, few spermatozoa were stored in the cauda region of the tract, and as many as 60% were located in the ductus deferens, the distal portion of which displayed a highly infolded epithelium and underlying lamina propria. These differences in histological structure of the hopping mouse excurrent ducts presumably reflect divergence in function of the various regions of the tract. Although the functional implications of the present findings remain to be determined, this study demonstrates the considerable plasticity in the male excurrent ducts amongst the hydromyine rodents of Australia. Images Figs. 1-2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Figs. 22-23 Fig. 24 Fig. 25 Fig. 26 PMID:2808117

  14. Bile Duct Exploration

    MedlinePlus

    ... Patients & Visitors Health Library Institutes & Departments Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Advertising Policy Bile Duct Exploration Common bile duct exploration is ...

  15. Trypsin level in gallbladder bile and ductitis and width of the cystic duct.

    PubMed

    Vracko, J; Wiechel, K L

    2000-01-01

    The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P < 0.001) and wider cystic ducts (P < 0.001) with more pronounced signs of chronic ductitis. The obtained results strongly suggest that the increased trypsin level, a sign of reflux of pancreatic juice, caused changes in the cystic duct that facilitate gallstone migration, which also ought to render a transcystic stone extraction feasible.

  16. Craniopharyngioma in the Temporal Lobe: A Case Report

    PubMed Central

    Baik, Seung Kug; Kim, Sang-Pyo; Kim, Il-Man; Sevick, Robert J.

    2004-01-01

    Herein, we report on an unusual case of craniopharyngioma arising in the temporal lobe with no prior history of surgery and with no connection to the craniopharyngeal duct. MR images showed a cystic tumor with a small solid portion. To the best of our knowledge, this is the first case of a craniopharyngioma occurring in the temporal lobe. PMID:15064562

  17. Quantification of Estrogen Receptor Expression in Normal Breast Tissue in Postmenopausal Women With Breast Cancer and Association With Tumor Subtypes.

    PubMed

    Gulbahce, H Evin; Blair, Cindy K; Sweeney, Carol; Salama, Mohamed E

    2017-09-01

    Estrogen exposure is important in the pathogenesis of breast cancer and is a contributing risk factor. In this study we quantified estrogen receptor (ER) alpha expression in normal breast epithelium (NBR) in women with breast cancer and correlated it with breast cancer subtypes. Tissue microarrays were constructed from 204 breast cancer patients for whom normal breast tissue away from tumor was available. Slides stained with ER were scanned and expression in normal terminal duct lobular epithelium was quantitated using computer-assisted image analysis. ER expression in normal terminal duct lobular epithelium of postmenopausal women with breast cancer was significantly associated with estrogen and triple (estrogen, progesterone receptors, and HER2) negative phenotypes. Also increased age at diagnosis was significantly associated with ER expression in NBR. ER positivity in normal epithelium did not vary by tumor size, lymph node status, tumor grade, or stage. On the basis of quantitative image analysis, we confirm that ER expression in NBR increases with age in women with breast cancer, and report for the first time, a significant association between ER expression in NBR with ER-negative and triple-negative cancers in postmenopausal women.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klingensmith, W.C.; Spitzer, V.M.; Fritzberg, A.R.

    Diisopropyl-IDA Tc 99m imaging studies were performed in 11 normal subjects in both the fasting and postprandial states. In 5- to 60-minute analog images obtained in both fasting and postprandial studies, the cardiac blood pool was almost never seen, renal pelvic radioactivity was commonly seen, the extrahepatic biliary tract was always seen, and the left hepatic duct was always more prominent than the right hepatic duct. The biliary tract was visualized by ten minutes in nine of 11 fasting studies and 10 of 11 postprandial studies. The gallbladder was visualized in all eleven fasting studies, but in only four postprandialmore » studies. The gallbladder was visualized in all eleven fasting studies, but in only four postprandial studies (p less than 0.05). The zero- to sixty-minute digital data indicated a greater hepatocyte clearance, an earlier time of peak parenchymal radioactivity, and a faster parenchymal washout in the postprandial studies compared with fasting studies (p less than 0.05). Approximately nine percent of the injected dose was recovered in the urine during the first three hours in fasting and postprandial studies. The normal diisopropyl-IDA Tc 99m study in the fasting and postprandial states is defined; significant differences exist between the two states.« less

  19. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  20. User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1997-01-01

    The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

  1. Quantitative Infrared Image Analysis Of Thermally-Thin Cellulose Surface Temperatures During Upstream and Downstream Microgravity Flame Spread from A Central Ignition Line

    NASA Technical Reports Server (NTRS)

    Olson, Sandra L.; Lee, J. R.; Fujita, O.; Kikuchi, M.; Kashiwagi, T.

    2012-01-01

    Surface view calibrated infrared images of ignition and flame spread over a thin cellulose fuel were obtained at 30 Hz during microgravity flame spread tests in the 10 second Japan Microgravity Center (JAMIC). The tests also used a color video of the surface view and color images of the edge view using 35 millimeter 1600 Kodak Ektapress film at 2 Hz. The cellulose fuel samples (50% long fibers from lumi pine and 50% short fibers from birch) were made with an area density of 60 grams per square meters. The samples were mounted in the center of a 12 centimeter wide by 16 centimeter tall flow duct that uses a downstream fan to draw the air through the flow duct. Samples were ignited after the experiment package was released using a straight hot wire across the center of the 7.5 centimeter wide by 14 centimeter long samples. One case, at 1 atmosphere 35%O2 in N2, at a forced flow of 10 centimeters per second, is presented here. In this case, as the test progresses, the single flame begins to separate into simultaneous upstream and downstream flames. Surface temperature profiles are evaluated as a function of time, and temperature gradients for upstream and downstream flame spread are measured. Flame spread rates from IR image data are compared to visible image spread rate data. IR blackbody temperatures are compared to surface thermocouple readings to evaluate the effective emissivity of the pyrolyzing surface. Preheat lengths are evaluated both upstream and downstream of the central ignition point. A surface energy balance estimates the net heat flux from the flame to the fuel surface along the length of the fuel.

  2. Combustor assembly in a gas turbine engine

    DOEpatents

    Wiebe, David J; Fox, Timothy A

    2015-04-28

    A combustor assembly in a gas turbine engine includes a combustor device, a fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner surrounded by the flow sleeve. The fuel injection system provides fuel to be mixed with the pressurized air and ignited in the liner to create combustion products. The intermediate duct is disposed between the liner and the transition duct so as to define a path for the combustion products to flow from the liner to the transition duct. The intermediate duct is associated with the liner such that movement may occur therebetween, and the intermediate duct is associated with the transition duct such that movement may occur therebetween. The flow sleeve includes structure that defines an axial stop for limiting axial movement of the intermediate duct.

  3. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    PubMed

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  4. Building America Case Study: Compact Buried Ducts in a Hot-Humid Climate House, Lady's Island, South Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-02-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences, 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs, and 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less

  5. Compact Buried Ducts in a Hot-Humid Climate House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, Dave

    2016-01-07

    "9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less

  6. Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version

    Cancer.gov

    Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.

  7. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    PubMed Central

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248

  8. Ducted turbine theory with right angled ducts

    NASA Astrophysics Data System (ADS)

    McLaren-Gow, S.; Jamieson, P.; Graham, J. M. R.

    2014-06-01

    This paper describes the use of an inviscid approach to model a ducted turbine - also known as a diffuser augmented turbine - and a comparison of results with a particular one-dimensional theory. The aim of the investigation was to gain a better understanding of the relationship between a real duct and the ideal diffuser, which is a concept that is developed in the theory. A range of right angled ducts, which have a rim for a 90° exit angle, were modelled. As a result, the performance of right angled ducts has been characterised in inviscid flow. It was concluded that right angled ducts cannot match the performance of their associated ideal diffuser and that the optimum rotor loading for these turbines varies with the duct dimensions.

  9. Air conditioning system and component therefore distributing air flow from opposite directions

    NASA Technical Reports Server (NTRS)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  10. [Iatrogenic bile duct injuries during the process of laparoscopic cholecystectomy].

    PubMed

    Qian, G; Wu, M; Zhang, Y

    1995-11-01

    Twelve patients with iatrogenic bile duct injuries occurred during laparoscopic cholecystectomy (LC) were treated from June 1992 to May 1994. All the patients underwent re-operation and were cured. The causes and characteristics of the injuries were: (1) perforation of the common hepatic or common bile duct caused by dissecting hook (3 cases); (2) necrosis and perforation of the common hepatic duct due to diathermic injury (1 case); (3) clamping of the common hepatic duct by Ti clip (1 case); (4) secondary high bile duct stricture following a failed end-to-end anastomosis or hepatico-cholangio-jejunostomy of the amputated common hepatic duct (5 cases); (5) delayed high bile duct stricture (2 cases). It is emphasized that the severity of bile duct injuries by LC be should not overlooked, and more experience in this field be accumulated to avoid this serious complication.

  11. Diagnostic evaluations of ultrasound and magnetic resonance imaging in mammary duct ectasia and breast cancer

    PubMed Central

    Song, Lei; Li, Liang; Liu, Bin; Yu, Dexin; Sun, Fengguo; Guo, Mingming; Ruan, Zhengmin; Zhang, Feixue

    2018-01-01

    The objective of the present study was to evaluate the diagnostic efficiency of ultrasound (US) and magnetic resonance imaging (MRI) in the diagnosis and differential diagnosis of mammary duct ectasia (MDE) and breast cancer. This retrospective study was performed on 35 patients with MDE and 105 patients with breast cancer using US and MRI. Imaging features, semi-quantitative and quantitative parameters were analyzed to determine their diagnostic value for MDE and breast cancer. The average age of patients with breast cancer was increased compared with that of patients with MDE. There were no significant differences in local packages with or without tenderness ratio (P=0.259) and grade of color Doppler flow imaging (P=0.273) between the two groups. However, the morphological changes were significantly increased in breast cancer compared with MDE. In addition, there were significant diagnostic differences in US and MRI between breast cancer and MDE, including resistance index, US elastography, time-signal intensity curve, apparent diffusion coefficient, early-stage enhancement ratio, peak-of-enhancement ratio and Tpeak (P<0.05). However, there were no observable significant diagnostic differences between US, MRI and US with MRI for MDE and breast cancer (P=0.103, P=0.263 and P=0.403 respectively). Diagnosis of MDE and breast cancer requires full evaluation of multiple parameters and morphological changes of US and MRI to increase the diagnostic efficiency. US, MRI and US with MRI were all of diagnostic value for MDE and breast cancer, while US with MRI had the highest efficacy. PMID:29434865

  12. Use of fiber reinforced polymer composite cable for post-tensioning application : [summary].

    DOT National Transportation Integrated Search

    2015-05-01

    Post-tensioning is a method frequently used in construction of segmental bridges, continuous : I-girder bridges, and piers. It involves using tendons, which are multiple strands, usually : steel, installed through voids formed by ducts either inside ...

  13. Excess intraoperative fluid volume administration is associated with pancreatic fistula after pancreaticoduodenectomy

    PubMed Central

    Han, In Woong; Kim, Hongbeom; Heo, JinSeok; Oh, Min Gu; Choi, Yoo Shin; Lee, Seung Eun; Lim, Chang-Sup

    2017-01-01

    Abstract Recent studies on perioperative fluid administration in patients undergoing pancreaticoduodenectomy (PD) have suggested that increased fluid loads are associated with worse perioperative outcomes. The purpose of this study was to investigate the relationship between intraoperative fluid (IOF) administration and postoperative pancreatic fistula (POPF), and to determine additional risk factors affecting pancreatic fistula in patients undergoing PD. From 2005 to 2014, a total of 182 patients with various periampullary diseases after PD were reviewed retrospectively at Dongguk University Ilsan Hospital, Chung-Ang University Hospital, and Dongnam Institute of Radiological and Medical Sciences. Patients were assigned to high or low IOF groups based on more or less fluid administration for supplementation of estimated blood loss and maintenance volume (12.5 mL/kg/h) than planned, respectively. The associations between IOF administration, pancreatic fistula development, and perioperative outcomes were evaluated. A total of 98 patients were assigned to the high-IOF group, and 84 to the low-IOF group. Risk factors for pancreatic fistula after univariate analysis were assignment to the high-IOF group, higher preoperative serum hemoglobin level, ampullary or bile duct cancer, pylorus preserving PD, small pancreatic duct, duct-to-mucosa pancreatojejunostomy, use of a stent, and mesh application to pancreatojejunal anastomosis. Among these, assignment to the high-IOF group (hazard ratio [HR] = 5.501, 95% CI 1.624–18.632, P = .006) and a small (<4 mm) pancreatic duct (HR = 4.129, 95% CI 1.569–14.658, P = .035) were identified as independent risk factors for the development of pancreatic fistula after multivariate analysis. However, long-term survival rate did not differ according to IOF group or duct size. Excessive IOF volume administration is associated with an increased incidence of pancreatic fistula after pancreaticoduodenectomy. PMID:28562540

  14. NASA Tech Briefs, June 2009

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Topics covered include: Device for Measuring Low Flow Speed in a Duct, Measuring Thermal Conductivity of a Small Insulation Sample, Alignment Jig for the Precise Measurement of THz Radiation, Autoignition Chamber for Remote Testing of Pyrotechnic Devices, Microwave Power Combiners for Signals of Arbitrary Amplitude, Synthetic Foveal Imaging Technology, Airborne Antenna System for Minimum-Cycle-Slip GPS Reception, Improved Starting Materials for Back-Illuminated Imagers, Multi-Modulator for Bandwidth-Efficient Communication, Some Improvements in Utilization of Flash Memory Devices, GPS/MEMS IMU/Microprocessor Board for Navigation, T/R Multi-Chip MMIC Modules for 150 GHz, Pneumatic Haptic Interfaces, Device Acquires and Retains Rock or Ice Samples, Cryogenic Feedthrough Test Rig, Improved Assembly for Gas Shielding During Welding or Brazing, Two-Step Plasma Process for Cleaning Indium Bonding Bumps, Tool for Crimping Flexible Circuit Leads, Yb14MnSb11 as a High-Efficiency Thermoelectric Material, Polyimide-Foam/Aerogel Composites for Thermal Insulation, Converting CSV Files to RKSML Files, Service Management Database for DSN Equipment, Chemochromic Hydrogen Leak Detectors, Compatibility of Segments of Thermoelectric Generators, Complementary Barrier Infrared Detector, JPL Greenland Moulin Exploration Probe, Ultra-Lightweight Self-Deployable Nanocomposite Structure for Habitat Applications, and Room-Temperature Ionic Liquids for Electrochemical Capacitors.

  15. Wave scattering in spatially inhomogeneous currents

    NASA Astrophysics Data System (ADS)

    Churilov, Semyon; Ermakov, Andrei; Stepanyants, Yury

    2017-09-01

    We analytically study a scattering of long linear surface waves on stationary currents in a duct (canal) of constant depth and variable width. It is assumed that the background velocity linearly increases or decreases with the longitudinal coordinate due to the gradual variation of duct width. Such a model admits an analytical solution of the problem in hand, and we calculate the scattering coefficients as functions of incident wave frequency for all possible cases of sub-, super-, and transcritical currents. For completeness we study both cocurrent and countercurrent wave propagation in accelerating and decelerating currents. The results obtained are analyzed in application to recent analog gravity experiments and shed light on the problem of hydrodynamic modeling of Hawking radiation.

  16. Risk Factors for Bile Duct Injury After Percutaneous Thermal Ablation of Malignant Liver Tumors: A Retrospective Case-Control Study.

    PubMed

    Lin, Man-Xia; Ye, Jie-Yi; Tian, Wen-Shuo; Xu, Ming; Zhuang, Bo-Wen; Lu, Ming-De; Xie, Xiao-Yan; Kuang, Ming

    2017-04-01

    Bile duct injury after ablation of malignant liver tumors (MLTs) was not unusual and should be avoided. However, few studies have focused on evaluating the risk factors for intrahepatic bile duct injury. To evaluate the risk factors for intrahepatic bile duct injury after ablation of MLTs and to evaluate the minimum safe distance for ablating tumors abutting bile ducts. Sixty-five patients with intrahepatic bile duct injury after ablation of MLTs, and 65 controls were recruited. Risk factors for intrahepatic bile duct injury were analyzed. Tumor location was recorded as ≤5 mm (group A), 5-10 mm (group B), and >10 mm (group C) from the right/left main duct or segmental bile duct. Ascites history (P < 0.001), TACE treatment history (P = 0.025), intrahepatic bile duct dilatation before ablation (P < 0.001), and tumor location (P = 0.000) were identified as significant risk factors for intrahepatic bile duct injury. Significant differences in the risk of intrahepatic bile duct injury were found between groups B and C (P = 0.000), but not between groups A and B (P = 0.751). Ascites history (P = 0.002) and tumor location (P < 0.001) were independent predictors with the OR (95 % confidence interval) of 39.31(3.95-391.69) and 16.56 (5.87-46.71), respectively. Bile duct injury after ablation of MLTs was the result of local treatment-related factors combined with the patients' general condition. The minimum safe distance for ablation of tumor abutting a bile duct was 10 mm.

  17. Assessment of Chronological Effects of Irreversible Electroporation on Hilar Bile Ducts in a Porcine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Jae Woong, E-mail: cooljay@korea.ac.kr; Lu, David S. K., E-mail: dlu@mednet.ucla.edu; Osuagwu, Ferdnand, E-mail: fosuagwu@mednet.ucla.edu

    2013-11-07

    PurposeTo evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology.Materials and MethodsTwelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE.more » Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks.ResultsNonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts.ConclusionIn the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.« less

  18. Biliary complications after right lobe living donor liver transplantation: a single-centre experience

    PubMed Central

    Yaprak, Onur; Dayangac, Murat; Akyildiz, Murat; Demirbas, Tolga; Guler, Necdet; Bulutcu, Fisun; Bassullu, Nuray; Akun, Elif; Yuzer, Yildiray; Tokat, Yaman

    2012-01-01

    Background Biliary complications that developed after right lobe liver transplantation from living donors were studied in a single centre. Methods From 2004 to 2010, 200 consecutive living donor right lobe liver transplantations were performed. The database was evaluated retrospectively. Biliary complications were diagnosed according to clinical, biochemical and radiological tests. The number of biliary ducts in the transplanted graft, the surgical techniques used for anastomosis, biliary strictures and bile leakage rates were analysed. Results Of a total of 200 grafts, 117 invloved a single bile duct, 77 had two bile ducts and in six grafts there were three bile ducts. In 166 transplants, the anastomosis was performed as a single duct to duct, in 21 transplants double duct to ducts, in one transplant, three duct to ducts and in 12 transplants as a Roux-en-Y reconstruction. In all, 40 bile leakages (20%) and 17 biliary strictures (8.5%) were observed in 49 patients resulting in a total of 57 biliary complications (28.5%). Seventeen patients were re-operated (12 as a result of bile leakages and five owing to biliary strictures). Conclusion Identification of more than one biliary orifice in the graft resulted in an increase in the complication rates. In grafts containing multiple orifices, performing multiple duct-to-duct (DD) or Roux-en-Y anastomoses led to a lower number of complications. PMID:22151451

  19. Traumatic resin ducts as indicators of bark beetle outbreaks

    Treesearch

    R. Justin DeRose; Matthew F. Bekker; James N. Long

    2017-01-01

    The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...

  20. Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version

    Cancer.gov

    Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.

  1. CPI-613 in Treating Patients With Advanced or Metastatic Bile Duct Cancer That Cannot Be Removed By Surgery

    ClinicalTrials.gov

    2018-05-22

    Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Unresectable Extrahepatic Bile Duct Cancer

  2. Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC

    NASA Astrophysics Data System (ADS)

    Shin, Hyun-Joon; Lee, Jong-Seung; Lee, Kang-Hoon; Han, Myung-Ryun; Hur, Eui-Beom; Shin, Sung-Chul

    2013-09-01

    This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.

  3. Comparison of clinicopathological characteristics between patients with occupational and non-occupational intrahepatic cholangiocarcinoma.

    PubMed

    Hamano, Genya; Kubo, Shoji; Takemura, Shigekazu; Tanaka, Shogo; Shinkawa, Hiroji; Kinoshita, Masahiko; Ito, Tokuji; Yamamoto, Takatsugu; Wakasa, Kenichi; Shibata, Toshihiko

    2016-07-01

    An outbreak of cholangiocarcinoma has been reported among workers of an offset color proof-printing department at a printing company in Japan. In this study, we compared the clinicopathological findings of this type of intrahepatic cholangiocarcinoma (occupational ICC) and non-occupational ICC. The clinical records of 51 patients with perihilar-type ICC who underwent liver resection, including five patients with occupational ICC were retrospectively reviewed. The clinicopathological features were compared. In the occupational group, the patients were significantly younger (P < 0.01), while serum γ-glutamyl transpeptidase activity and the proportions of patients with regional dilatation of the bile ducts without tumor-induced obstruction were significantly higher (P = 0.041 and P < 0.01, respectively); the indocyanine green retention rate at 15 min was significantly lower (P = 0.020). On pathological examinations, precancerous or early cancerous lesions, such as biliary intraepithelial neoplasia and intraductal papillary neoplasm of the bile duct, were observed at various sites of the bile ducts in all occupational ICC patients; such lesions were observed in only six patients in the control group (P < 0.01). The clinicopathological findings including age, liver function test results, diagnostic imaging findings, and pathological findings differed between the occupational and control groups. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  4. Unexpected Occurrence of Mesospheric Frontal Gravity Wave Events Over South Pole (90°S)

    NASA Astrophysics Data System (ADS)

    Pautet, P.-D.; Taylor, M. J.; Snively, J. B.; Solorio, C.

    2018-01-01

    Since 2010, Utah State University has operated an infrared Advanced Mesospheric Temperature Mapper at the Amundsen-Scott South Pole station to investigate the upper atmosphere dynamics and temperature deep within the vortex. A surprising number of "frontal" gravity wave events (86) were recorded in the mesospheric OH(3,1) band intensity and rotational temperature images (typical altitude of 87 km) during four austral winters (2012-2015). These events are gravity waves (GWs) characterized by a sharp leading wave front followed by a quasi-monochromatic wave train that grows with time. A particular subset of frontal gravity wave events has been identified in the past (Dewan & Picard, 1998) as "bores." These are usually associated with wave ducting within stable mesospheric inversion layers, which allow them to propagate over very large distances. They have been observed on numerous occasions from low-latitude and midlatitude sites, but to date, very few have been reported at high latitudes. This study provides new analyses of the characteristics of frontal events at high latitudes and shows that most of them are likely ducted. The occurrence of these frontal GW events over this isolated region strongly supports the existence of horizontally extensive mesospheric thermal inversion layers over Antarctica, leading to regions of enhanced stability necessary for GW trapping and ducting.

  5. Convolution seal for transition duct in turbine system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston

    2015-05-26

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature andmore » the adjacent transition duct.« less

  6. Mammary Duct Ectasia

    MedlinePlus

    ... tenderness or inflammation of the clogged duct (periductal mastitis). Mammary duct ectasia most often occurs in women ... that's turned inward (inverted) A bacterial infection called mastitis also may develop in the affected milk duct, ...

  7. Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

    NASA Technical Reports Server (NTRS)

    Beckemeyer, R. J.; Sawdy, D. T.

    1971-01-01

    An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

  8. Dynamic Observation of the Morphological Changes in Paraurethral Ducts Infected with Gonococci in Men before and after Ceftriaxone Therapy Using High-Frequency Ultrasound.

    PubMed

    Fan, Wenge; Zhang, Qingsong; Ye, Xun; Fan, Zhijiang

    2018-01-01

    To observe the morphological changes in paraurethral ducts infected with gonococci in men before and after the administration of the ceftriaxone therapy using high-frequency ultrasound and determine its clinical significance. Thirty-two male patients with gonococcal paraurethral duct infection were enrolled. Their lesions were examined using an ACUSON X300 ultrasound system before and after they were subjected to ceftriaxone therapy. The paraurethral duct was completely closed 3-4 days after ceftriaxone treatment in 30 patients. Paraurethral duct closure began from the blind end and proceeded gradually towards its orifice; during closure, the paraurethral duct diameter showed no apparent change. These 30 patients whose paraurethral ducts closed were considered cured. In the remaining 2 patients, the length and diameter of the paraurethral ducts showed no change before and after ceftriaxone treatment; one patient was unresponsive to ceftriaxone treatment, and the other had secondary dilatation of the paraurethral duct. These 2 patients were cured after surgery. High-frequency ultrasound enables dynamic observation of the morphological changes in paraurethral ducts infected with gonococci before and after ceftriaxone therapy. High-frequency ultrasound can provide valuable information for incision, drainage, and wedge resection of paraurethral ducts. © 2017 S. Karger AG, Basel.

  9. Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

    NASA Technical Reports Server (NTRS)

    Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.

    1997-01-01

    This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

  10. Advanced Duct Sealing Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherman, Max H.; Walker, Iain S.

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected weekly. The baking test specimens were visually inspected weekly, and the durability was judged by the observed deterioration in terms of brittleness, cracking, flaking and blistering (the terminology used in the UL 181B-FX test procedure).« less

  11. Flame behaviors of propane/air premixed flame propagation in a closed rectangular duct with a 90-deg bend

    NASA Astrophysics Data System (ADS)

    He, Xuechao; Sun, Jinhua; Yuen, K. K.; Ding, Yibin; Chen, Sining

    2008-11-01

    Experiments of flame propagation in a small, closed rectangular duct with a 90° bend were performed for a propane-air mixture. The high speed camera and Schlieren techniques were used to record images of flame propagation process in the combustion pipe. Meanwhile, the fine thermocouples and ion current probes were applied to measure the temperature distribution and reaction intensity of combustion. The characteristics of propane-air flame and its microstructure were analyzed in detail by the experimental results. In the test, the special tulip flame formation was observed. Around the bend, the flame tip proceeded more quickly at the lower side with the flame front elongated toward the axial direction. And transition to turbulent flame occurred. It was suggested that fluctuations of velocity, ion current and temperature were mainly due to the comprehensive effects of multi-wave and the intense of turbulent combustion.

  12. Endoscopic Modified Medial Maxillectomy for Resection of an Inverted Papilloma Originating from the Entire Circumference of the Maxillary Sinus

    PubMed Central

    Wada, Kota; Ishigaki, Takashi; Ida, Yutaro; Yamada, Yuki; Hosono, Sachiko; Edamatsu, Hideo

    2015-01-01

    For treatment of a sinonasal inverted papilloma (IP), it is essential to have a definite diagnosis, to identify its origin by computed tomography (CT) and magnetic resonance imaging (MRI), and to select the appropriate surgical approach based on the staging system proposed by Krouse. Recently, a new surgical approach named endoscopic modified medial maxillectomy (EMMM) was proposed. This approach can preserve the inferior turbinate and nasolacrimal duct. We successfully treated sinonasal IP with EMMM in a 71-year-old female patient. In this patient, the sinonasal IP originated from the entire circumference of the maxillary sinus. EMMM is not a difficult procedure and provides good visibility of the operative field. Lacrimation and empty nose syndrome do not occur postoperatively as the nasolacrimal duct and inferior turbinate are preserved. EMMM is considered to be a very favorable approach for treatment of sinonasal IP. PMID:26146581

  13. [A Case of Adenoma of the Nipple Suspected of Breast Cancer].

    PubMed

    Takada, Koji; Kashiwagi, Shinichiro; Goto, Wataru; Asano, Yuka; Morisaki, Tamami; Noda, Satoru; Takashima, Tsutomu; Onoda, Naoyoshi; Ohsawa, Masahiko; Hirakawa, Kosei; Ohira, Masaichi

    2017-11-01

    Adenoma of the nipple is a rare benign tumor, and it is important to distinguish from Paget's disease or breast cancer. A 45- year-old woman had found induration under the right areola before 2 months and visited our hospital. Ultrasonography showed a 2.4 cm solid tumor in a cystic lesion, which had high blood flow in E area of the right mammary gland. The tumor suspected as duct papillomatosis by core needle biopsy. No metastasis lesion was found by computed tomography and bone scintigraphy. But magnetic resonance imaging showed as a marginally clear tumor with contrast enhanced findings that were relatively early reinforced and prolonged. Because there was a possibility of malignancy based on these findings, tumorectomy was done with patient consent. Histological examination revealed usual ductal hyperplasia(duct papillomatosis)and no malignancy. No recurrence was seen for a year after operation. When diagnosing a tumor under areola, be careful not to misdiagnose malignancy.

  14. [Stenon or Stensen duct. How sholud we call the secretory duct of the parotid gland? Brief biography of its discoverer].

    PubMed

    Morais Pérez, D

    2004-01-01

    The duct of the parotid gland had been indiscriminately named Stenon's duct or Stensen's duct. In order to establish its origin we carried out a biographic search and a brief revision of the life of the great anatomist, geologist, palaeontologist, bishop and finally Saint Nicolaus Stensen.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scofield, C.M.; Des Champs, N.H.

    This article examines a design concept for classroom air conditioning systems that guarantees minimum ventilation rates are met. The topics of the article include new ventilation requirements, design concept, outside air induction diffuser, low-velocity ducts and plenums, the relationship of humidity to school absenteeism rates, retrofit applications, and saving energy.

  16. Flexible Vesiculovasoscopy Using a Microoptical System in a Human Cadaver Model: An Experimental Approach for Atraumatic Endoscopy of the Seminal Tract.

    PubMed

    Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz

    2016-08-01

    The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.

  17. Experimental and Numerical Study on Performance of Ducted Hydrokinetic Turbines with Pre-Swirl Stator Blades.

    NASA Astrophysics Data System (ADS)

    Gish, Andrew

    2015-11-01

    Ducts (also called shrouds) have been shown to improve performance of hydrokinetic turbines in some situations, bringing the power coefficient (Cp) closer to the Betz limit. Here we investigate optimization of the duct design as well as the addition of stator blades upstream of the turbine rotor to introduce pre-swirl in the flow. A small scale three-bladed turbine was tested in a towing tank. Three cases (bare turbine, with duct, and with duct and stators) were tested over a range of flow speeds. Important parameters include duct cross-sectional shape, blade-duct gap, stator cross-sectional shape, and stator angle. For each test, Cp was evaluated as a function of tip speed ratio (TSR). Experimental results were compared with numerical simulations. Results indicate that ducts and stators can improve performance at slower flow speeds and lower the stall speed compared to a bare turbine, but may degrade performance at higher speeds. Ongoing efforts to optimize duct and stator configurations will be discussed.

  18. Investigation of the tone-burst tube for duct lining attenuation measurement

    NASA Technical Reports Server (NTRS)

    Soffel, A. R.; Morrow, P. F.

    1972-01-01

    The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

  19. Multispectral Fluorescence Imaging During Robot-assisted Laparoscopic Sentinel Node Biopsy: A First Step Towards a Fluorescence-based Anatomic Roadmap.

    PubMed

    van den Berg, Nynke S; Buckle, Tessa; KleinJan, Gijs H; van der Poel, Henk G; van Leeuwen, Fijs W B

    2017-07-01

    During (robot-assisted) sentinel node (SN) biopsy procedures, intraoperative fluorescence imaging can be used to enhance radioguided SN excision. For this combined pre- and intraoperative SN identification was realized using the hybrid SN tracer, indocyanine green- 99m Tc-nanocolloid. Combining this dedicated SN tracer with a lymphangiographic tracer such as fluorescein may further enhance the accuracy of SN biopsy. Clinical evaluation of a multispectral fluorescence guided surgery approach using the dedicated SN tracer ICG- 99m Tc-nanocolloid, the lymphangiographic tracer fluorescein, and a commercially available fluorescence laparoscope. Pilot study in ten patients with prostate cancer. Following ICG- 99m Tc-nanocolloid administration and preoperative lymphoscintigraphy and single-photon emission computed tomograpy imaging, the number and location of SNs were determined. Fluorescein was injected intraprostatically immediately after the patient was anesthetized. A multispectral fluorescence laparoscope was used intraoperatively to identify both fluorescent signatures. Multispectral fluorescence imaging during robot-assisted radical prostatectomy with extended pelvic lymph node dissection and SN biopsy. (1) Number and location of preoperatively identified SNs. (2) Number and location of SNs intraoperatively identified via ICG- 99m Tc-nanocolloid imaging. (3) Rate of intraoperative lymphatic duct identification via fluorescein imaging. (4) Tumor status of excised (sentinel) lymph node(s). (5) Postoperative complications and follow-up. Near-infrared fluorescence imaging of ICG- 99m Tc-nanocolloid visualized 85.3% of the SNs. In 8/10 patients, fluorescein imaging allowed bright and accurate identification of lymphatic ducts, although higher background staining and tracer washout were observed. The main limitation is the small patient population. Our findings indicate that a lymphangiographic tracer can provide additional information during SN biopsy based on ICG- 99m Tc-nanocolloid. The study suggests that multispectral fluorescence image-guided surgery is clinically feasible. We evaluated the concept of surgical fluorescence guidance using differently colored dyes that visualize complementary features. In the future this concept may provide better guidance towards diseased tissue while sparing healthy tissue, and could thus improve functional and oncologic outcomes. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. Ursodeoxycholic acid after bile duct stone removal and risk factors for recurrence: a randomized trial.

    PubMed

    Yamamoto, Ryuichi; Tazuma, Susumu; Kanno, Keishi; Igarashi, Yoshinori; Inui, Kazuo; Ohara, Hirotaka; Tsuyuguchi, Toshio; Ryozawa, Shomei

    2016-02-01

    Currently, no established pharmacologic treatment exists for the prevention of recurrent common bile duct (CBD) stones. Here, we present a multi-center randomized trial that compared the CBD recurrence rate after bile duct stone removal between patients given ursodeoxycholic acid (UDCA) and the untreated group. A total of 36 patients were randomly assigned to either the UDCA (n = 15) or the untreated group (n = 21). The primary end-point was the recurrence rate of CBD stones. The recurrence rate of CBD stones was 6.6% in the UDCA group and 18.6% in the untreated group (P = 0.171). A multivariate analysis found that not receiving UDCA was an independent risk factor for stone recurrence. The recurrence rates of CBD stones did not differ by sex, past history of cholecystectomy, or the presence of gallstones. Our findings indicate that UDCA may be a novel treatment strategy to prevent the recurrence of CBD stones. However, further evaluation of UDCA in a larger number of subjects will be required to confirm the applicability of these results. © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  1. An estimate of the noise shielding on the fuselage resulting from installing a short duct around an advanced propeller

    NASA Technical Reports Server (NTRS)

    Dittmar, James H.

    1988-01-01

    A simple barrier shielding model was used to estimate the amount of noise shielding on the fuselage that could result from installing a short duct around a wing-mounted advanced propeller. With the propeller located one-third of the duct length from the inlet, estimates for the maximum blade passing tone attenuation varied from 7 dB for a duct 0.25 propeller diameter long to 16.75 dB for a duct 1 diameter long. Attenuations for the higher harmonics would be even larger because of their shorter wavelengths relative to the duct length. These estimates show that the fuselage noise reduction potential of a ducted compared with an unducted propeller is significant. Even more reduction might occur if acoustic attenuation material were installed in the duct.

  2. Coupled parametric design of flow control and duct shape

    NASA Technical Reports Server (NTRS)

    Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)

    2009-01-01

    A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.

  3. Design integration and noise studies for jet STOL aircraft. Task 7C: Augmentor wing cruise blowing valveless system. Volume 2: Small-scale development testing of augmentor wing critical ducting components

    NASA Technical Reports Server (NTRS)

    Runnels, J. N.; Gupfa, A.

    1973-01-01

    Augmentor wing ducting system studies conducted on a valveless system configuration that provides cruise thrust from the augmentor nozzles have shown that most of the duct system pressure loss would occur in the strut-wing duct y-junction and the wing duct-augmentor lobe nozzles. These components were selected for development testing over a range of duct Mach numbers and pressure ratios to provide a technical basis for predicting installed wing thrust loading and for evaluating design wing loading of a particular wing aspect ratios. The flow characteristics of ducting components with relatively high pressure loss coefficients were investigated. The turbulent pressure fluctuations associated with flows at high Mach numbers were analyzed to evaluate potential duct fatigue problems.

  4. Pancreatic-duct-lavage cytology in candidates for surgical resection of branch-duct intraductal papillary mucinous neoplasm of the pancreas: should the International Consensus Guidelines be revised?

    PubMed

    Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki

    2009-03-01

    The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.

  5. Decline of the performance of a portable axial-flow fan due to the friction and duct bending loss of a connected flexible duct.

    PubMed

    Ojima, Jun

    2017-03-28

    In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.

  6. Eversion Bile Duct Anastomosis: A Safe Alternative for Bile Duct Size Discrepancy in Deceased Donor Liver Transplantation.

    PubMed

    Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw

    2018-04-10

    Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  7. New endoscopic and cytologic tools for cancer surveillance in the digestive tract

    PubMed Central

    Brentnall, Teresa A.; Dominitz, Jason A.

    2009-01-01

    Synopsis Cancer surveillance is an increasing part of everyday practice in gastrointestinal endoscopy due to the identification of high risk groups from genetic and biomarker testing, genealogic and epidemiologic studies, and the increasing number of cancer survivors. An efficient surveillance program requires a cost-effective means for image-guided cancer detection and biopsy. A laser-based tethered-capsule endoscope with enhanced spectral imaging is introduced for unsedated surveillance of the lower esophagus. An ultrathin version of this same endoscope technology provides a 1.2-mm guidewire with imaging capability and cannula-style tools are proposed for image-guided biopsy. Advanced 3D cell visualization techniques are described for increasing the sensitivity of early cancer diagnosis from hematoxylin-stained cells sampled from the pancreatic and biliary ducts. PMID:19423026

  8. Simultaneous stimulated Raman scattering and higher harmonic generation imaging for liver disease diagnosis without labeling

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Wang, Zi; Zheng, Wei; Huang, Zhiwei

    2014-02-01

    Nonlinear optical microscopy (e.g., higher harmonic (second-/third- harmonic) generation (HHG), simulated Raman scattering (SRS)) has high diagnostic sensitivity and chemical specificity, making it a promising tool for label-free tissue and cell imaging. In this work, we report a development of a simultaneous SRS and HHG imaging technique for characterization of liver disease in a bile-duct-ligation rat-modal. HHG visualizes collagens formation and reveals the cell morphologic changes associated with liver fibrosis; whereas SRS identifies the distributions of hepatic fat cells formed in steatosis liver tissue. This work shows that the co-registration of SRS and HHG images can be an effective means for label-free diagnosis and characterization of liver steatosis/fibrosis at the cellular and molecular levels.

  9. A case of annular pancreas with Wirsung's duct encircling the duodenum: embryological hypothesis based on cholangiopancreatographic and immunohistochemical findings.

    PubMed

    Fukai, Manami; Kamisawa, Terumi; Horiguchi, Shin-Ichirou; Hishima, Tsunekazu; Kuruma, Sawako; Chiba, Kazuro; Koizumi, Satomi; Tabata, Taku; Nagao, Sayaka; Kikuyama, Masataka; Honda, Goro; Kurata, Masanao

    2017-06-01

    We present a resected case of annular pancreas in which Wirsung's duct encircled the duodenum and continued directly to the main pancreatic duct in the body and tail. Furthermore, Wirsung's duct coursed along the right side of the lower bile duct near the major duodenal papilla. Histologically, the islets of Langerhans in the annular pancreas were irregular in shape and were characterized by a striking abundance of pancreatic polypeptide (PP)-positive cells. The PP-rich area that encircled the duodenum was fused with the PP-poor area in the head of the pancreas. The following embryological hypothesis is proposed. The tip of the ventral pancreatic anlage adhered to the duodenal wall and stretched to form a ring during clockwise rotation. The rotation was incomplete, and the pancreatic duct did not cross over the lower bile duct. Since there was adequate ventral anlage in the lower part of the head of the pancreas, fusion between the ducts of the ventral and dorsal anlagen did not occur. The tip of the ventral anlage overgrew and adhered to the dorsal anlage, and the annular duct fused with the main duct of the dorsal anlage.

  10. Reciprocity principle in duct acoustics

    NASA Technical Reports Server (NTRS)

    Cho, Y.-C.

    1979-01-01

    Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.

  11. On Computations of Duct Acoustics with Near Cut-Off Frequency

    NASA Technical Reports Server (NTRS)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  12. Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2011-01-01

    The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.

  13. Common path endoscopic probes for optical coherence tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Singh, Kanwarpal; Gardecki, Joseph A.; Tearney, Guillermo J.

    2017-02-01

    Background: Dispersion imbalance and polarization mismatch between the reference and sample arm signals can lead to image quality degradation in optical coherence tomography (OCT). One approach to reduce these image artifacts is to employ a common-path geometry in fiber-based probes. In this work, we report an 800 um diameter all-fiber common-path monolithic probe for coronary artery imaging where the reference signal is generated using an inline fiber partial reflector. Methods: Our common-path probe was designed for swept-source based Fourier domain OCT at 1310 nm wavelength. A face of a coreless fiber was coated with gold and spliced to a standard SMF-28 single mode fiber creating an inline partial reflector, which acted as a reference surface. The other face of the coreless fiber was shaped into a ball lens for focusing. The optical elements were assembled within a 560 µm diameter drive shaft, which was attached to a rotary junction. The drive shaft was placed inside a transparent sheath having an outer diameter of 800 µm. Results: With a source input power of 30mW, the inline common-path probe achieved a sensitivity of 104 dB. Images of human finger skin showed the characteristic layers of skin as well as features such as sweat ducts. Images of coronary arteries ex vivo obtained with this probe enabled visualization of the characteristic architectural morphology of the normal artery wall and known features of atherosclerotic plaque. Conclusion: In this work, we have demonstrated a common path OCT probe for cardiovascular imaging. The probe is easy to fabricate, will reduce system complexity and overall cost. We believe that this design will be helpful in endoscopic applications that require high resolution and a compact form factor.

  14. Abernethy malformation associated with Caroli's syndrome in a patient with a PKHD1 mutation: a case report.

    PubMed

    Mi, Xiao-Xiao; Li, Xiao-Guang; Wang, Zi-Rong; Lin, Ling; Xu, Chun-Hai; Shi, Jun-Ping

    2017-08-16

    Abernethy malformation is a rare congenital anomaly characterised by the partial or complete absence of the portal vein and the subsequent development of an extrahepatic portosystemic shunt. Caroli's disease is a rare congenital condition characterised by non-obstructive saccular intrahepatic bile duct dilation. Caroli's disease combined with congenital hepatic fibrosis and/or renal cystic disease is referred to - Caroli's syndrome. The combination of Abernethy malformation and Caroli's syndrome has not been reported previously. We present the case of a 23-year-old female who was found to have both type II Abernethy malformation and Caroli's syndrome. Radiological imaging was performed, including computed tomography with three-dimensional reconstruction and magnetic resonance imaging with (magnetic resonance cholangiopancreatography (MRCP), which revealed a side-to-side portocaval shunt, intrahepatic bile duct dilation, congenital hepatic fibrosis, and renal cysts. In addition, PKHD1 (polycystic kidney and hepatic disease 1) gene mutational analysis revealed a paternally inherited heterozygous missense mutation (c.1877A > G, p.Lys626Arg). A liver biopsy confirmed the pathological features of Caroli's syndrome. To our knowledge, this is the first reported case of a patient with both type II Abernethy malformation and Caroli's syndrome diagnosed using a comprehensive approach that included imaging, mutational analysis, and liver biopsy. Additionally, this is the second reported case to date of an Asian patient presenting with liver and renal disorders with the same paternally inherited PKHD1 missense mutation.

  15. Investigation in the 7-by-10 Foot Wind Tunnel of Ducts for Cooling Radiators within an Airplane Wing

    NASA Technical Reports Server (NTRS)

    Harris, Thomas A; Recant, Isidore G

    1942-01-01

    Report presents the results of an investigation made in the NACA 7 by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional-flow setup with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included.

  16. CFD application to subsonic inlet airframe integration. [computational fluid dynamics (CFD)

    NASA Technical Reports Server (NTRS)

    Anderson, Bernhard H.

    1988-01-01

    The fluid dynamics of curved diffuser duct flows of military aircraft is discussed. Three-dimensional parabolized Navier-Stokes analysis, and experiment techniques are reviewed. Flow measurements and pressure distributions are shown. Velocity vectors, and the effects of vortex generators are considered.

  17. Results of a phase I-II study on intraductal confocal microscopy (IDCM) in patients with common bile duct (CBD) stenosis.

    PubMed

    Giovannini, M; Bories, E; Monges, G; Pesenti, C; Caillol, F; Delpero, J R

    2011-07-01

    Confocal endomicroscopy is an emergent technique and allows real optical biopsies in the gastrointestinal (GI) tract. The aim of this study was to evaluate a new intraductal confocal miniprobe in patients with a normal common bile duct (CBD) or with a suspicion of a malignant stenosis (cholangiocarcinoma). Thirty-seven patients (23 males) underwent endoscopic retrograde cholangiopancreatography (ERCP) for bile duct stone removal (7 cases) or bile duct stenosis (30 cases). Intraductal confocal microscopy (IDCM) was performed during the ERCP using a probe-based confocal laser endomicroscopy (pCLE) technique. IDCM was done with the CholangioFlex probe with Cellvizio (Mauna Kea Technologies, Paris, France). The depth of penetration of theCholangioFlex probe was 40-70 μm and magnification was 400×. Images were reviewed by an experienced pathologist in GI disease and compared to ERCP findings, CBD biopsies performed during ERCP or EUS, and in 15 patients to the resected specimen (Wipple resection). No complications related to the CholangioFlex insertion occurred after the ERCP. Good images were obtained in 33 patients. Final histology diagnosis was a normal CBD in 7 cases, 23 malignant stenoses (4 ampullary carcinomas, 13 cholangiocarcinomas, and 6 pancreatic cancer), and 7 inflammatory stenoses (4 chronic pancreatitis, 1 stenosis of hepaticojejunal anastomosis, 1 postcholecystectomy CBD stenosis, and 1 primary sclerosing cholangitis). IDCM of a normal CBD showed a thin black band (<20 μm), normal vessels (thin and regular), and no visible glands. IDCM of malignant strictures revealed irregular vessels with lack of contrast in the CBD wall, large black band (>20 μm), and an aggregate of irregular black cells (black clumps). These aspects were seen in all malignant stenoses and none were seen in benign or normal CBD. The presence of irregular vessels, large black bands, and black clumps seen with confocal laser microscopy enabled prediction of neoplasia with an accuracy rate of 86%, sensitivity of 83%, and specificity of 75%. The respective numbers for standard histopathology were 53, 65, and 53%. This phase I-II study on IDCM showed that IDCM is feasible. This new technique will open a new door for optical biopsy of the CBD.

  18. First observations of elevated ducts associated with intermittent turbulence in the stable boundary layer over Bosten Lake, China

    NASA Astrophysics Data System (ADS)

    Sun, Zheng; Ning, Hui; Song, Shihui; Yan, Dongmei

    2016-10-01

    Nocturnal radiative cooling is a main driver for atmospheric duct formation. Within this atmospheric process, the impacts of intermittent turbulence on ducting have seldom been studied. In this paper, we reported two confusing ducting events observed in the early morning in August 2014 over Bosten Lake, China, when a stable boundary layer (SBL) still survived, by using tethered high-resolution GPS radiosondes. Elevated ducts with strong humidity inversions were observed during the balloon ascents but were absent during observations made upon the balloon descents several minutes later. This phenomenon was initially hypothesized to be attributable to turbulence motions in the SBL, and the connection between the turbulence event and the radar duct was examined by the statistical Thorpe method. Turbulence patches were detected from the ascent profiles but not from the descent profiles. The possible reasons for the duct formation and elimination were discussed in detail. The turbulent transport of moisture in the SBL and the advection due to airflows coming from the lake are the most probable reasons for duct formation. In one case, the downward transport of moisture by turbulence mixing within a Kelvin-Helmholtz billow at the top of the low-level jet resulted in duct elimination. In another case, the passage of density currents originating from the lake may have caused the elimination of the duct. Few studies have attempted to associate intermittent turbulence with radar ducts; thus, this work represents a pioneering study into the connection between turbulent events and atmospheric ducts in a SBL.

  19. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beal, D.; McIlvaine , J.; Fonorow, K.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition tomore » enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.« less

  20. An iPhone application using a novel stool color detection algorithm for biliary atresia screening.

    PubMed

    Hoshino, Eri; Hayashi, Kuniyoshi; Suzuki, Mitsuyoshi; Obatake, Masayuki; Urayama, Kevin Y; Nakano, Satoshi; Taura, Yasuyuki; Nio, Masaki; Takahashi, Osamu

    2017-10-01

    The stool color card has been the primary tool for identifying acholic stools in infants with biliary atresia (BA), in several countries. However, BA stools are not always acholic, as obliteration of the bile duct occurs gradually. This study aims to introduce Baby Poop (Baby unchi in Japanese), a free iPhone application, employing a detection algorithm to capture subtle differences in colors, even with non-acholic BA stools. The application is designed for use by caregivers of infants aged approximately 2 weeks-1 month. Baseline analysis to determine optimal color parameters predicting BA stools was performed using logistic regression (n = 50). Pattern recognition and machine learning processes were performed using 30 BA and 34 non-BA images. Additional 5 BA and 35 non-BA pictures were used to test accuracy. Hue, saturation, and value (HSV) were the preferred parameter for BA stool identification. A sensitivity and specificity were 100% (95% confidence interval 0.48-1.00 and 0.90-1.00, respectively) even among a collection of visually non-acholic, i.e., pigmented BA stools and relatively pale-colored non-BA stools. Results suggest that an iPhone mobile application integrated with a detection algorithm is an effective and convenient modality for early detection of BA, and potentially for other related diseases.

  1. [Expression of calponin and P63 in human submandibular glands].

    PubMed

    Lu, Yu-he; Gao, Yan

    2007-02-01

    To observe the expression of new myoepithelial cell markers calponin and P63 in human submandibular glands. Calponin and P63 antigen in routinely processed human submandibular gland tissues were immunohistochemically demonstrated by monoclonal antibodies to calponin and P63. Calponin expressed around all acinus and intercalated ducts as linear or punctuate pattern. Positive staining was also noted in peripheral area of some thin striated ducts that connect to intercalated ducts. Subulate or trigonal calponin expression was sometimes seen between the duct dells of striated ducts. P63 expressed mainly in the nucleus of the basal cells of excretory duct. Calponin is an ideal gland. P63 labels mainly the basal cells of excretory duct. marker for myoepithelial cells of human submandibular

  2. Total rupture of hydatid cyst of liver in to common bile duct: a case report.

    PubMed

    Robleh, Hassan; Yassine, Fahmi; Driss, Khaiz; Khalid, Elhattabi; Fatima-Zahra, Bensardi; Saad, Berrada; Rachid, Lefriyekh; Abdalaziz, Fadil; Najib, Zerouali Ouariti

    2014-01-01

    Rupture of hydatid liver cyst into biliary tree is frequent complications that involve the common hepatic duct, lobar biliary branches, the small intrahepatic bile ducts,but rarely rupture into common bile duct. The rupture of hydatid cyst is serious life threating event. The authors are reporting a case of total rupture of hydatid cyst of liver into common bile duct. A 50-year-old male patient who presented with acute cholangitis was diagnosed as a case of totally rupture of hydatid cyst on Abdominal CT Scan. Rupture of hydatid cyst of liver into common bile duct and the gallbladder was confirmed on surgery. Treated by cholecystectomy and T-tube drainage of Common bile duct.

  3. Preliminary Investigation of Curved Liner Sample in the NASA LaRC Curved Duct Test Rig

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.

    2007-01-01

    This viewgraph presentation reviews the preliminary investigation of the curved liner sample in the NASA LaRC Curved Duct Test Rig (CDTR). It reviews the purpose of the Curved Duct Test Rig. Its purpose is to develop capability to investigate acoustic and aerodynamic properties in ducts. It has several features to accomplish that purpose: (1) Large scale (2) Flow rate to M = 0.275 (3) Higher order mode control (4) Curved flow path (5) Adaptable test section (6) Flexible test configurations. The liner has minimal effect on turbulence or boundary layer growth in duct. The curved duct sample attenuation is affected by mode scattering. In conclusion, the CDTR is valid tool for aerodynamic and acoustic evaluation of duct treatment

  4. Post-Tensioning Duct Air Pressure Testing Effects on Web Cracking

    DOT National Transportation Integrated Search

    2015-01-01

    Nevada Department of Transportation (NDOT) post-tensioned concrete bridges have experienced web cracking near the post-tensioning ducts during the construction process. The ducts were air pressure tested to ensure the duct can successfully be grouted...

  5. Cholangiocarcinoma in a middle-aged patient working at a printing plant.

    PubMed

    Tanaka, Shogo; Fukumoto, Nobusuke; Ohno, Kohichi; Tanaka, Sayaka; Ohsawa, Masahiko; Yamamoto, Takatsugu; Nakanuma, Yasuni; Kuboo, Shoji

    2014-06-01

    A 39-year-old male with elevated serum transferases consulted our hospital in September 2010. Since 1999, he had worked at a printing company using organic solvents. Cholangiography revealed stenosis of the left hepatic duct with peripheral dilation, stricture of the right hepatic duct, and irregularity of the extrahepatic bile duct. As a preoperative diagnosis of sclerosing cholangitis and cholangiocarcinoma was made, extended left hepatectomy with resection of the extrahepatic bile duct and anastomosis of the anterior and posterior branches of the bile duct and the jejunum (Roux-en Y reconstruction) were performed. A histological examination showed papillary carcinoma of the medial hepatic bile duct with intraductal growth, and biliary intraepithelial neoplasia-2/3 lesions from the medial hepatic bile duct to the right hepatic and the common bile ducts. Chronic cholangitis was shown around the tumors. Postoperatively, the patient was treated with adjuvant chemo-radiation, and he is doing well 30 months after the operation, without recurrence. Unknown causes, including exposure to organic solvents, might have induced chronic bile duct injury and contributed to the development of cholangiocarcinoma.

  6. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature

    PubMed Central

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones. PMID:27047698

  7. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature.

    PubMed

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones.

  8. Isolated Main Pancreatic Duct Dilatation: CT Differentiation Between Benign and Malignant Causes.

    PubMed

    Kim, Se Woo; Kim, Se Hyung; Lee, Dong Ho; Lee, Sang Min; Kim, Yeon Soo; Jang, Jin Young; Han, Joon Koo

    2017-11-01

    The purpose of this study is to retrospectively evaluate the differential CT features of isolated benign and malignant main pancreatic duct (MPD) dilatation and to investigate whether the diagnostic performance of radiologists can be improved with knowledge of these differential CT features. Forty-one patients who had isolated MPD dilatation without any visible mass on CT from January 2000 to October 2016 were retrospectively enrolled in the study. Two radiologists reviewed CT images in consensus for the location, shape (smooth vs abrupt), length of transition, dilated pancreatic duct (PD) diameter, presence of duct penetrating sign, parenchymal atrophy, attenuation difference, associated pancreatitis, calcification, PD or common bile duct (CBD) enhancement, and perilesional cyst. The chi-square test, Fisher exact test, and t test were used to find the differential CT features of benign and malignant MPD dilatation. Two successive review sessions for differentiation between the two disease entities were then independently performed by three other reviewers with differing expertise, with the use of a 5-point confidence scale. The first session provided no information for differentiation; however, reviewers were aware of the results of univariate analyses in the second session. The diagnostic performance of the radiologists was evaluated using a pairwise comparison of ROC curves. A total of 19 benign and 22 malignant MPD dilatations were identified. In patients with benign MPD dilatation, transition areas were frequently located in the head (57.9% [11/19] vs 13.6% [3/22], p = 0.003) and showed significantly shorter (< 6.1 mm) (78.9% [15/19] vs 9.1% [2/22], p < 0.0001) and smooth transition (89.5% [17/19] vs 9.1% [2/22], p < 0.0001). Duct penetrating sign was exclusively observed in patients with benign MPD dilatation (73.7% [14/19] vs 0% [0/22], p < 0.0001). In contrast, malignant MPD dilatation frequently was accompanied by attenuation difference (63.6% [14/22] vs 10.5% [2/19], p = 0.001) and associated PD or CBD enhancement (36.4% [8/22] vs 0% [0/19], p = 0.003). The AUC values of three reviewers significantly increased from 0.653, 0.587, and 0.884 to 0.864, 0.964, and 0.908, respectively, with knowledge of significant CT features (p = 0.013, p < 0.0001, and p = 0.701, respectively). Distal, long (≥ 6.1 mm), and abrupt transition, the absence of duct penetrating sign, and the presence of attenuation difference and PD or CBD enhancement were highly suggestive CT findings for differentiation of malignant from benign MPD dilatation. The diagnostic performance of radiologists with regard to differentiation was significantly improved with knowledge of these highly suggestive CT criteria.

  9. Premix fuels study applicable to duct burner conditions for a variable cycle engine

    NASA Technical Reports Server (NTRS)

    Venkataramani, K. S.

    1978-01-01

    Emission levels and performance of a premixing Jet-A/air duct burner were measured at reference conditions representative of take-off and cruise for a variable cycle engine. In a parametric variation sequence of tests, data were obtained at inlet temperatures of 400, 500 and 600K at equivalence ratios varying from 0.9 to the lean stability limit. Ignition was achieved at all the reference conditions although the CO levels were very high. Significant nonuniformity across the combustor was observed for the emissions at the take-off condition. At a reference Mach number of 0.117 and an inlet temperature of 600K, corresponding to a simulated cruise condition, the NOx emission level was approximately 1 gm/kg-fuel.

  10. Optimized multisectioned acoustic liners

    NASA Technical Reports Server (NTRS)

    Baumeister, K. J.

    1979-01-01

    New calculations show that segmenting is most efficient at high frequencies with relatively long duct lengths where the attenuation is low for both uniform and segmented liners. Statistical considerations indicate little advantage in using optimized liners with more than two segments while the bandwidth of an optimized two-segment liner is shown to be nearly equal to that of a uniform liner. Multielement liner calculations show a large degradation in performance due to changes in assumed input modal structure. Computer programs are used to generate theoretical attenuations for a number of liner configurations for liners in a rectangular duct with no mean flow. Overall, the use of optimized multisectioned liners fails to offer sufficient advantage over a uniform liner to warrant their use except in low frequency single mode application.

  11. Computer-Simulation Surrogates for Optimization: Application to Trapezoidal Ducts and Axisymmetric Bodies

    NASA Technical Reports Server (NTRS)

    Otto, John C.; Paraschivoiu, Marius; Yesilyurt, Serhat; Patera, Anthony T.

    1995-01-01

    Engineering design and optimization efforts using computational systems rapidly become resource intensive. The goal of the surrogate-based approach is to perform a complete optimization with limited resources. In this paper we present a Bayesian-validated approach that informs the designer as to how well the surrogate performs; in particular, our surrogate framework provides precise (albeit probabilistic) bounds on the errors incurred in the surrogate-for-simulation substitution. The theory and algorithms of our computer{simulation surrogate framework are first described. The utility of the framework is then demonstrated through two illustrative examples: maximization of the flowrate of fully developed ow in trapezoidal ducts; and design of an axisymmetric body that achieves a target Stokes drag.

  12. Rapid detonation initiation by sparks in a short duct: a numerical study

    NASA Astrophysics Data System (ADS)

    Hu, Z. M.; Dou, H. S.; Khoo, B. C.

    2010-06-01

    Rapid onset of detonation can efficiently increase the working frequency of a pulse detonation engine (PDE). In the present study, computations of detonation initiation in a duct are conducted to investigate the mechanisms of detonation initiation. The governing equations are the Euler equations and the chemical kinetic model consists of 19 elementary reactions and nine species. Different techniques of initiation have been studied for the purpose of accelerating detonation onset with a relatively weak ignition energy. It is found that detonation ignition induced by means of multiple sparks is applicable to auto-ignition for a PDE. The interaction among shock waves, flame fronts and the strip of pre-compressed fresh (unburned) mixture plays an important role in rapid onset of detonation.

  13. Ducting Conditions for Electromagnetic Wave Propagation in Tropical Disturbances from GPS Dropsonde Data

    DTIC Science & Technology

    2013-12-01

    depression, tropical storm , hurricane, extratropical cyclone, subtropical depression, subtropical storm , a low of no category, tropical wave, disturbance or...surface-based ducts, and elevated ducts. We further separate the duct occurrence based on the location relative to their respective storms . Based...on the number of soundings in different types of tropical disturbances, we chose to further analyze duct conditions in hurricanes and tropical storms

  14. Mucocele of the cystic duct remnant after orthotopic liver transplant: a problem revisited.

    PubMed

    Chatterjee, Suvadip; Das, Debasish; Hudson, Mark; Bassendine, Margaret Fiona; Scott, John; Oppong, Kofi Ernest; Sen, Gourab; French, Jeremy J

    2011-06-01

    Mucocele of the cystic duct remnant is an uncommon hepatobiliary complication of a liver transplant. Current practice usually involves either excising the cystic duct, or incorporating the distal end of the transected cystic duct into the suture line of the biliary anastomosis to ensure drainage. We report a patient who developed cystic duct remnant mucocele after the latter approach was adopted. We believe that this is likely related to delayed anastomotic stricturing, which prevented draining from the remnant cystic duct. We also discuss the incidence, pathology, investigations, and treatment of this condition.

  15. Simple resection of the lesion bile duct branch for treatment of regional hepatic bile duct stones

    PubMed Central

    Enliang, Li; Rongshou, Wu; Shidai, Shi; Jingling, Zhang; Qian, Feng; Wenjun, Liao; Linquan, Wu

    2017-01-01

    Abstract To evaluate the effectiveness and safety of simple resections of bile duct branch lesions for the treatment of regional hepatic bile duct stones. A retrospective analysis of the clinical data from patients in our hospital from November 2008 to November 2015, who only underwent a simple resection of the lesion bile duct branch. The patients’ clinical characteristics, surgical features, postoperative complications, stone clear rate, residual stone rate, and recurrence stone rate were analyzed. This study of 32 patients included 13 males and 19 females with intrahepatic bile duct stones confined to the right hepatic bile duct branch. The intraoperative blood loss, operation time, and postoperative hospital stay were 478.0 ± 86.5, 210.7 ± 6.6, and 10.8 ± 3.5, respectively. Postoperative complications occurred in 6 patients (18.8%), all of whom recovered with conservative management. There were no deaths during hospitalization. The intraoperative stone clearance rate was 95.8%. Three patients had a recurrence of stones at a mean of 22 months of follow-up (range, 4–36 months). Simple resection of bile duct branch lesions is safe and feasible for patients who have regional hepatic bile duct stones limited to the right hepatic bile duct branches. PMID:28682899

  16. A Plug-and-Play Duct System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beach, Robert; Dickson, Bruce; Grisolia, Anthony

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less

  17. Anatomic Variation in Intrahepatic Bile Ducts: an Analysis of Intraoperative Cholangiograms in 300 Consecutive Donors for Living Donor Liver Transplantation

    PubMed Central

    Choi, Jin Woo; Kim, Kyoung Won; Kim, Ah Young; Kim, Pyo Nyun; Ha, Hyun Kwon; Lee, Moon-Gyu

    2003-01-01

    Objective To describe the anatomical variation occurring in intrahepatic bile ducts (IHDs) in terms of their branching patterns, and to determine the frequency of each variation. Materials and Methods The study group consisted of 300 consecutive donors for liver transplantation who underwent intraoperative cholangiography. Anatomical variation in IHDs was classified according to the branching pattern of the right anterior and right posterior segmental duct (RASD and RPSD, respectively), and the presence or absence of the first-order branch of the left hepatic duct (LHD), and of an accessory hepatic duct. Results The anatomy of the intrahepatic bile ducts was typical in 63% of cases (n=188), showed triple confluence in 10% (n=29), anomalous drainage of the RPSD into the LHD in 11% (n=34), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 6% (n=19), anomalous drainage of the RPSD into the cystic duct in 2% (n=6), drainage of the right hepatic duct (RHD) into the cystic duct (n=1), the presence of an accessory duct leading to the CHD or RHD in 5% (n=16), individual drainage of the LHD into the RHD or CHD in 1% (n=4), and unclassified or complex variation in 1% (n=3). Conclusion The branching pattern of IHDs was atypical in 37% of cases. The two most common variations were drainage of the RPSD into the LHD (11%) and triple confluence of the RASD, RPSD and LHD (10%). PMID:12845303

  18. On modeling the sound propagation through a lined duct with a modified Ingard-Myers boundary condition

    NASA Astrophysics Data System (ADS)

    Yang, Cheng; Fang, Yi; Zhao, Chao; Zhang, Xin

    2018-06-01

    A duct acoustics model is an essential component of an impedance eduction technique and its computation cost determines the impedance measurement efficiency. In this paper, a model is developed for the sound propagation through a lined duct carrying a uniform mean flow. In contrast to many existing models, the interface between the liner and the duct field is defined with a modified Ingard-Myers boundary condition that takes account of the effect of the boundary layer above the liner. A mode-matching method is used to couple the unlined and lined duct segments for the model development. For the lined duct segment, the eigenvalue problem resulted from the modified boundary condition is solved by an integration scheme which, on the one hand, allows the lined duct modes to be computed in an efficient manner, and on the other hand, orders the modes automatically. The duct acoustics model developed from the solved lined duct modes is shown to converge more rapidly than the one developed from the rigid-walled duct modes. Validation against the experiment data in the literature shows that the proposed model is able to predict more accurately the liner performance measured by the two-source method. This, however, cannot be made by a duct acoustics model associated with the conventional Ingard-Myers boundary condition. The proposed model has the potential to be integrated into an impedance eduction technique for more reliable liner measurement.

  19. Synchronous double primary cancers of the extrahepatic bile duct: A case report and literature review.

    PubMed

    Nishi, Takeshi; Sato, Yoshitoshi; Hanaoka, Takuya; Takahashi, Takuya; Miura, Hiroshi; Takubo, Kenji

    2018-01-01

    Double cancers of the biliary tract system are rare. Most of these cancers are synchronous double cancers of the gall bladder and bile duct, associated with pancreaticobiliary maljunction (PBM). Synchronous double cancers of the extrahepatic bile duct without PBM are especially rare, and only 4 cases have been reported. A 78-year-old woman was admitted to our hospital for examination of hyperbilirubinemia and liver dysfunction. Contrast-enhanced abdominal computed tomography, Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography revealed 2 stenotic regions in the common bile duct: at its junction with the cystic duct and in the distal bile duct. No findings suggested PBM, such as a markedly long common channel. The diagnosis based on endoscopic brush cytology from both stricture portions was adenocarcinoma. The patient had a pylorus-preserving pancreaticoduodenectomy with regional lymph node resection. Macroscopically, there were 2 stenotic regions at the cystic duct junction and in the distal bile duct. Microscopically, the tumor at the junction of the cystic duct was a well-to-moderately differentiated adenocarcinoma. On the other hand, the tumor of the distal bile duct was a poorly differentiated adenocarcinoma. There was no evidence of communication between these 2 cancers. Double cancers of the extrahepatic bile duct without PBM are very rare. Therefore, an accurate diagnosis prior to surgery is necessary. Furthermore, this rare condition seems to be associated with a poor prognosis. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Relationship Between Bile Duct Reconstruction and Complications in Living Donor Liver Transplantation.

    PubMed

    Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S

    2016-05-01

    In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A Plug-and-Play Duct System Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beach, R.; Dickson, B.; Grisolia, A.

    2017-07-01

    This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less

  2. Mockup Small-Diameter Air Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke and A. Rudd

    2016-05-01

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less

  4. Anatomic variations in intrahepatic bile ducts in a north Indian population.

    PubMed

    Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas

    2008-07-01

    In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).

  5. 3D molecular MR imaging of liver fibrosis and response to rapamycin therapy in a bile duct ligation rat model.

    PubMed

    Farrar, Christian T; DePeralta, Danielle K; Day, Helen; Rietz, Tyson A; Wei, Lan; Lauwers, Gregory Y; Keil, Boris; Subramaniam, Arun; Sinskey, Anthony J; Tanabe, Kenneth K; Fuchs, Bryan C; Caravan, Peter

    2015-09-01

    Liver biopsy, the gold standard for assessing liver fibrosis, suffers from limitations due to sampling error and invasiveness. There is therefore a critical need for methods to non-invasively quantify fibrosis throughout the entire liver. The goal of this study was to use molecular Magnetic Resonance Imaging (MRI) of Type I collagen to non-invasively image liver fibrosis and assess response to rapamycin therapy. Liver fibrosis was induced in rats by bile duct ligation (BDL). MRI was performed 4, 10, or 18 days following BDL. Some BDL rats were treated daily with rapamycin starting on day 4 and imaged on day 18. A three-dimensional (3D) inversion recovery MRI sequence was used to quantify the change in liver longitudinal relaxation rate (ΔR1) induced by the collagen-targeted probe EP-3533. Liver tissue was subjected to pathologic scoring of fibrosis and analyzed for Sirius Red staining and hydroxyproline content. ΔR1 increased significantly with time following BDL compared to controls in agreement with ex vivo measures of increasing fibrosis. Receiver operating characteristic curve analysis demonstrated the ability of ΔR1 to detect liver fibrosis and distinguish intermediate and late stages of fibrosis. EP-3533 MRI correctly characterized the response to rapamycin in 11 out of 12 treated rats compared to the standard of collagen proportional area (CPA). 3D MRI enabled characterization of disease heterogeneity throughout the whole liver. EP-3533 allowed for staging of liver fibrosis, assessment of response to rapamycin therapy, and demonstrated the ability to detect heterogeneity in liver fibrosis. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  6. Incidental radiographic findings of thyroglossal duct cysts: Prevalence and management.

    PubMed

    Yim, Michael T; Tran, Huy D; Chandy, Binoy M

    2016-10-01

    To determine the epidemiology of incidental thyroglossal duct cysts (TGDC) discovered on imaging studies obtained in the head and neck area in children and to discuss subsequent management. A retrospective chart review was performed at Texas Children's Hospital of all computed tomography (CT) and magnetic resonance (MR) imaging studies obtained in the head and neck region between July 2011 and July 2014. Images obtained for the purpose of evaluating a neck or lingual mass were excluded from the study, as were patients with previously known TGDCs. Data including age, sex, location of TGDC, size, presence of symptoms, referral to Otolaryngology, and intervention were recorded. A total of 60,663 CT and MR studies of the head, brain, sinus, neck, and C-spine during this time period were reviewed; of these 69 (0.1%) cases contained incidental discovery of probable TGDCs with more males (40) than females (29). Ages ranged from 3 days to 17 years old, with the mean age at 5 years. Locations varied, with majority at base of tongue (83%) followed by hyoid (13%) then infrahyoid straps (4%). Sizes ranged from 2 to 28 mm with average size at 8 mm. 11 of these patients were referred to an Otolaryngologist; 9 were asymptomatic and decision was made to observe, the other two subsequently underwent surgical excision secondary to mass effect and dysphagia with histologic confirmation of diagnosis. TGDCs commonly present as an anterior neck mass, however the majority of incidentally discovered TGDCs on imaging are located at the base of tongue. Management of these findings should include referral to an Otolaryngologist for further evaluation with the decision to intervene surgically based on development of clinical symptoms. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Case study of mesospheric front dissipation observed over the northeast of Brazil

    NASA Astrophysics Data System (ADS)

    Fragoso Medeiros, Amauri; Paulino, Igo; Wrasse, Cristiano Max; Fechine, Joaquim; Takahashi, Hisao; Valentin Bageston, José; Paulino, Ana Roberta; Arlen Buriti, Ricardo

    2018-03-01

    On 3 October 2005 a mesospheric front was observed over São João do Cariri (7.4° S, 36.5° W). This front propagated to the northeast and appeared in the airglow images on the west side of the observatory. By about 1.5 h later, it dissipated completely when the front crossed the local zenith. Ahead of the front, several ripple structures appeared during the dissipative process of the front. Using coincident temperature profile from the TIMED/SABER satellite and wind profiles from a meteor radar at São João do Cariri, the background of the atmosphere was investigated in detail. On the one hand, it was noted that a strong vertical wind shear in the propagation direction of the front produced by a semidiunal thermal tide was mainly responsible for the formation of duct (Doppler duct), in which the front propagated up to the zenith of the images. On the other hand, the evolution of the Richardson number as well as the appearance of ripples ahead of the main front suggested that a presence of instability in the airglow layer that did not allow the propagation of the front to the other side of the local zenith.

  8. Improved Merge Valve

    NASA Technical Reports Server (NTRS)

    George-Falvy, Dez

    1992-01-01

    Circumferential design combines compactness and efficiency. In remotely controlled valve, flow in tributary duct along circumference of primary duct merged with flow in primary duct. Flow in tributary duct regulated by variable throat nuzzle driven by worm gear. Design leak-proof, and most components easily fabricated on lathe.

  9. Correcting negatively biased refractivity below ducts in GNSS radio occultation: an optimal estimation approach towards improving planetary boundary layer (PBL) characterization

    NASA Astrophysics Data System (ADS)

    Wang, Kuo-Nung; de la Torre Juárez, Manuel; Ao, Chi O.; Xie, Feiqin

    2017-12-01

    Global Navigation Satellite System (GNSS) radio occultation (RO) measurements are promising in sensing the vertical structure of the Earth's planetary boundary layer (PBL). However, large refractivity changes near the top of PBL can cause ducting and lead to a negative bias in the retrieved refractivity within the PBL (below ˜ 2 km). To remove the bias, a reconstruction method with assumption of linear structure inside the ducting layer models has been proposed by Xie et al. (2006). While the negative bias can be reduced drastically as demonstrated in the simulation, the lack of high-quality surface refractivity constraint makes its application to real RO data difficult. In this paper, we use the widely available precipitable water (PW) satellite observation as the external constraint for the bias correction. A new framework is proposed to incorporate optimization into the RO reconstruction retrievals in the presence of ducting conditions. The new method uses optimal estimation to select the best refractivity solution whose PW and PBL height best match the externally retrieved PW and the known a priori states, respectively. The near-coincident PW retrievals from AMSR-E microwave radiometer instruments are used as an external observational constraint. This new reconstruction method is tested on both the simulated GNSS-RO profiles and the actual GNSS-RO data. Our results show that the proposed method can greatly reduce the negative refractivity bias when compared to the traditional Abel inversion.

  10. Analysis of biliary anatomy according to different classification systems.

    PubMed

    Deka, Pranjal; Islam, Mahibul; Jindal, Deepti; Kumar, Niteen; Arora, Ankur; Negi, Sanjay Singh

    2014-01-01

    Variations in biliary anatomy are common, and different classifications have been described. These classification systems have not been compared to each other in a single cohort. We report such variations in biliary anatomy on magnetic resonance cholangiopancreatography (MRCP) using six different classification systems. In 299 patients undergoing MRCP for various indications, biliary anatomy was classified as described by Couinaud (1957), Huang (1996), Karakas (2008), Choi (2003), Champetier (1994), and Ohkubo (2004). Correlation with direct cholangiography and vascular anatomy was done. Bile duct dimensions were measured. Cystic duct junction and pancreaticobiliary ductal junction (PBDJ) were classified. Normal biliary anatomy was noted in 57.8 %. The most common variants were Couinaud type D2, Choi type 3A, Huang type A1, Champetier type a, Ohkubo types D and J, and Karakas type 2a. The Ohkubo classification was the most appropriate; 3.1 % of right ducts and 6.3 % of left ducts with variant anatomy could not be classified using the Ohkubo classification. There was a good agreement between MRCP and direct cholangiography (ĸ = 0.9). Anomalous PBDJ was noted in 8.7 %. Variant biliary anatomy was not associated with gender (p = 0.194) or variant vascular anatomy (p = 0.24). Although each classification system has its merits and demerits, some anatomical variations cannot be classified using any of the previously described classifications. The Ohkubo classification system is the most applicable as it considers most clinically relevant variations pertinent to hepatobiliary surgery.

  11. Computer Software Management and Information Center

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Computer programs for passive anti-roll tank, earth resources laboratory applications, the NIMBUS-7 coastal zone color scanner derived products, transportable applications executive, plastic and failure analysis of composites, velocity gradient method for calculating velocities in an axisymmetric annular duct, an integrated procurement management system, data I/O PRON for the Motorola exorcisor, aerodynamic shock-layer shape, kinematic modeling, hardware library for a graphics computer, and a file archival system are documented.

  12. Optical Demonstration of a Medical Imaging System with an EMCCD-Sensor Array for Use in a High Resolution Dynamic X-ray Imager

    PubMed Central

    Qu, Bin; Huang, Ying; Wang, Weiyuan; Sharma, Prateek; Kuhls-Gilcrist, Andrew T.; Cartwright, Alexander N.; Titus, Albert H.; Bednarek, Daniel R.; Rudin, Stephen

    2011-01-01

    Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained. PMID:23505330

  13. Assessment of fibrotic liver disease with multimodal nonlinear optical microscopy

    NASA Astrophysics Data System (ADS)

    Lu, Fake; Zheng, Wei; Tai, Dean C. S.; Lin, Jian; Yu, Hanry; Huang, Zhiwei

    2010-02-01

    Liver fibrosis is the excessive accumulation of extracellular matrix proteins such as collagens, which may result in cirrhosis, liver failure, and portal hypertension. In this study, we apply a multimodal nonlinear optical microscopy platform developed to investigate the fibrotic liver diseases in rat models established by performing bile duct ligation (BDL) surgery. The three nonlinear microscopy imaging modalities are implemented on the same sectioned tissues of diseased model sequentially: i.e., second harmonic generation (SHG) imaging quantifies the contents of the collagens, the two-photon excitation fluorescence (TPEF) imaging reveals the morphology of hepatic cells, while coherent anti-Stokes Raman scattering (CARS) imaging maps the distributions of fats or lipids quantitatively across the tissue. Our imaging results show that during the development of liver fibrosis (collagens) in BDL model, fatty liver disease also occurs. The aggregated concentrations of collagen and fat constituents in liver fibrosis model show a certain correlationship between each other.

  14. Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.

    PubMed

    Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin

    2013-06-01

    Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot system, complicated billiary reconstruction can be performed (http://links.lww.com/SLE/A74).

  15. A novel technique of percutaneous stone extraction in choledocholithiasis after cholecystostomy.

    PubMed

    Lim, Kyoung Hoon; Kim, Yong Joo

    2013-05-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous common bile duct stone extraction via cystic duct after percutaneous cholecystostomy. Twenty-five consecutive patients with choledocholithiasis underwent percutaneous stone extraction under conscious sedation. The stones were extracted through the 12-Fr sheath using Wittich nitinol stone basket under fluoroscopic guidance via cystic duct after percutaneous trnas-hepatic cholecystostomy. Common bile duct stones were successfully removed in 22 of the 25 patients (88%) by this new technique. The causes of failure in three patients were bile leakage, hematoma of the gallbladder and failure of cystic duct cannulation. Cystic duct injury during this procedure did not occur and there was no post-procedure mortality. The mean period of indwelling catheter was 8.7±4.6 days and the mean duration of hospitalization was 13.4±5.9 days. Percutaneous commmon bile duct stone extraction via the cystic duct through percutaneous cholecystostomy route is effective and feasible for treating choledocholithiasis.

  16. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    PubMed

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  17. Study of Gas Solid Flow Characteristics in Cyclone Inlet Ducts of A300Mwe CFB Boiler

    NASA Astrophysics Data System (ADS)

    Tang, J. Y.; Lu, X. F.; Lai, J.; Liu, H. Z.

    Gas solid flow characteristics in cyclone's inlet duct of a 300MW CFB boiler were studied in a cold circulating fluidized bed (CFB) experimental setup according to a 410t/h CFB boiler with a scale of 10∶1. Tracer particles were adopted in the experiment and their motion trajectories in the two kinds of cyclone's inlet ducts were photographed by a high-speed camera. By analyzing the motion trajectories of tracer particles, acceleration performance of particle phases in the two inlet ducts was obtained. Results indicate that the acceleration performance of particles in the long inlet duct is better than that in the short inlet duct, but the pressure drop of the long inlet duct is higher. Meanwhile, under the same operating conditions, both the separation efficiency and the pressure drop of the cyclone are higher when the cyclone is connected with the long inlet duct. Figs 11, Tabs 4 and refs 10.

  18. Synchronous papillary carcinoma in thyroglossal duct cyst and thyroid gland: case report and review of literature.

    PubMed

    Cherian, Mathew Pynumootil; Nair, Balakrishnan; Thomas, Shaji; Somanathan, Thara; Sebastian, Paul

    2009-10-01

    We report a rare case of synchronous occurrence of thyroglossal duct cyst carcinoma and thyroid carcinoma and discuss its management in detail. A 59-year-old woman was clinically diagnosed to have a thyroglossal duct cyst and a solitary nodule. Fine-needle aspiration cytology revealed a papillary carcinoma in the thyroglossal duct cyst and a colloid in the thyroid nodule. Sistrunk's procedure along with a total thyroidectomy was performed followed by postoperative radioiodine ablation. Histopathologic examination revealed thyroglossal duct cyst carcinoma and bilateral foci of papillary carcinoma in the thyroid gland. She has remained free of disease on follow-up. Most cancers arising in thyroglossal duct cysts are of low risk, and Sistrunk's procedure is an adequate treatment for such cancers. However, for synchronously occurring cancers of the thyroglossal duct cyst and thyroid gland, or high-risk thyroglossal duct cyst cancers, more aggressive treatment comprising total thyroidectomy, Sistrunk's procedure, and radioiodine therapy is indicated. (c) 2009 Wiley Periodicals, Inc.

  19. [Clinicopathologic features of drug-induced vanishing bile duct syndrome].

    PubMed

    Ye, L H; Wang, C K; Zhang, H C; Liu, Z Q; Zheng, H W

    2017-04-20

    Vanishing bile duct syndrome (VBDS) manifests as progressive destruction and disappearance of the intrahepatic bile duct caused by various factors and cholestasis. VBDS associated with drug-induced liver injury (D-VBDS) is an important etiology of VBDS, and immune disorder or immune imbalance may be the main pathogenesis. According to its clinical symptoms, serological markers, and course of the disease, D-VBDS is classified into major form and minor form, and its clinical features are based on various pathomorphological findings. Its prognosis is associated various factors including regeneration of bile duct cells, number of bile duct injuries, level and range of bile duct injury, bile duct proliferation, and compensatory shunt of bile duct branches. This disease has various clinical outcomes; most patients have good prognosis after drug withdrawal, and some patients may experience cholestatic cirrhosis, liver failure, and even death. Due to the clinical manifestation and biochemical changes are similar to the primary biliary cholangitis (PBC) and primary sclerosing cholangitis (PSC), it need to identify by clinical physician.

  20. Cystic Duct Closure by Sealing With Bipolar Electrocoagulation

    PubMed Central

    Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.

    2010-01-01

    Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641

  1. Sealing ducts to save energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siuru, B.

    1996-07-01

    Large amounts of energy are wasted when heat leaks through ductwork located in uninsulated spaces. The Electric Power Research INstitute recently did a study that accurately measured these losses, then substantially reduced them by sealing the leaky ductwork. Six homes in the Pacific Northwest with significant duct leakage to the outside were selected for the study. The homes had electric resistance or heat pump, forced-air heating systems with a major portion of the supply and return ductwork in crawl spaces, attics, garages, etc. Measurements of duct leakage and heating system efficiency were done on all the homes before starting themore » duct sealing. Retrofitting included finding holes, gaps, cracks and disconnected joints in supply and return ducts as well as in plenums. When necessary, plenums were cut open for repairs. Leaks were sealed with Latex mastic and fiberglass tape. Outside ducts were covered or wrapped with insulation. Unducted returns were sealed with duct board. In some cases, leakage was corrected by merely reconnecting ducts and boots.« less

  2. Transient liquid-crystal technique used to produce high-resolution convective heat-transfer-coefficient maps

    NASA Technical Reports Server (NTRS)

    Hippensteele, Steven A.; Poinsatte, Philip E.

    1993-01-01

    In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.

  3. Design of power-plant installations pressure-loss characteristics of duct components

    NASA Technical Reports Server (NTRS)

    Henry, John R

    1944-01-01

    A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)

  4. Transition duct with divided upstream and downstream portions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier

    2015-07-14

    Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing themore » upstream portion and the downstream portion.« less

  5. Importance of resin ducts in reducing ponderosa pine mortality from bark beetle attack.

    PubMed

    Kane, Jeffrey M; Kolb, Thomas E

    2010-11-01

    The relative importance of growth and defense to tree mortality during drought and bark beetle attacks is poorly understood. We addressed this issue by comparing growth and defense characteristics between 25 pairs of ponderosa pine (Pinus ponderosa) trees that survived and trees that died from drought-associated bark beetle attacks in forests of northern Arizona, USA. The three major findings of our research were: (1) xylem resin ducts in live trees were >10% larger (diameter), >25% denser (no. of resin ducts mm(-2)), and composed >50% more area per unit ring growth than dead trees; (2) measures of defense, such as resin duct production (no. of resin ducts year(-1)) and the proportion of xylem ring area to resin ducts, not growth, were the best model parameters of ponderosa pine mortality; and (3) most correlations between annual variation in growth and resin duct characteristics were positive suggesting that conditions conducive to growth also increase resin duct production. Our results suggest that trees that survive drought and subsequent bark beetle attacks invest more carbon in resin defense than trees that die, and that carbon allocation to resin ducts is a more important determinant of tree mortality than allocation to radial growth.

  6. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1995-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  7. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1997-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  8. Balloon catheter dilation and nasolacrimal duct intubation for treatment of nasolacrimal duct obstruction after failed probing.

    PubMed

    Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins

    2009-05-01

    To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.

  9. Acute carbon tetrachloride feeding induces damage of large but not small cholangiocytes from BDL rat liver.

    PubMed

    LeSage, G D; Glaser, S S; Marucci, L; Benedetti, A; Phinizy, J L; Rodgers, R; Caligiuri, A; Papa, E; Tretjak, Z; Jezequel, A M; Holcomb, L A; Alpini, G

    1999-05-01

    Bile duct damage and/or loss is limited to a range of duct sizes in cholangiopathies. We tested the hypothesis that CCl4 damages only large ducts. CCl4 or mineral oil was given to bile duct-ligated (BDL) rats, and 1, 2, and 7 days later small and large cholangiocytes were purified and evaluated for apoptosis, proliferation, and secretion. In situ, we measured apoptosis by morphometric and TUNEL analysis and the number of small and large ducts by morphometry. Two days after CCl4 administration, we found an increased number of small ducts and reduced number of large ducts. In vitro apoptosis was observed only in large cholangiocytes, and this was accompanied by loss of proliferation and secretion in large cholangiocytes and loss of choleretic effect of secretin. Small cholangiocytes de novo express the secretin receptor gene and secretin-induced cAMP response. Consistent with damage of large ducts, we detected cytochrome P-4502E1 (which CCl4 converts to its radicals) only in large cholangiocytes. CCl4 induces selective apoptosis of large ducts associated with loss of large cholangiocyte proliferation and secretion.

  10. Numerical study on the impacts of the bogus data assimilation and sea spray parameterization on typhoon ducts

    NASA Astrophysics Data System (ADS)

    Fei, Jianfang; Ding, Juli; Huang, Xiaogang; Cheng, Xiaoping; Hu, Xiaohua

    2013-06-01

    The Weather Research and Forecasting model version 3.2 (WRF v3.2) was used with the bogus data assimilation (BDA) scheme and sea spray parameterization (SSP), and experiments were conducted to assess the impacts of the BDA and SSP on prediction of the typhoon ducting process induced by Typhoon Mindule (2004). The global positioning system (GPS) dropsonde observations were used for comparison. The results show that typhoon ducts are likely to form in every direction around the typhoon center, with the main type of ducts being elevated duct. With the BDA scheme included in the model initialization, the model has a better performance in predicting the existence, distribution, and strength of typhoon ducts. This improvement is attributed to the positive effect of the BDA scheme on the typhoon's ambient boundary layer structure. Sea spray affects typhoon ducts mainly by changing the latent heat (LH) flux at the air-sea interface beyond 270 km from the typhoon center. The strength of the typhoon duct is enhanced when the boundary layer under this duct is cooled and moistened by the sea spray; otherwise, the typhoon duct is weakened. The sea spray induced changes in the air-sea sensible heat (SH) flux and LH flux are concentrated in the maximum wind speed area near the typhoon center, and the changes are significantly weakened with the increase of the radial range.

  11. Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

    NASA Technical Reports Server (NTRS)

    Mclallin, K. L.; Kofskey, M. G.; Civinskas, K. C.

    1983-01-01

    The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

  12. Sclerosing Cholangitis: Clinicopathologic Features, Imaging Spectrum, and Systemic Approach to Differential Diagnosis.

    PubMed

    Seo, Nieun; Kim, So Yeon; Lee, Seung Soo; Byun, Jae Ho; Kim, Jin Hee; Kim, Hyoung Jung; Lee, Moon-Gyu

    2016-01-01

    Sclerosing cholangitis is a spectrum of chronic progressive cholestatic liver disease characterized by inflammation, fibrosis, and stricture of the bile ducts, which can be classified as primary and secondary sclerosing cholangitis. Primary sclerosing cholangitis is a chronic progressive liver disease of unknown cause. On the other hand, secondary sclerosing cholangitis has identifiable causes that include immunoglobulin G4-related sclerosing disease, recurrent pyogenic cholangitis, ischemic cholangitis, acquired immunodeficiency syndrome-related cholangitis, and eosinophilic cholangitis. In this review, we suggest a systemic approach to the differential diagnosis of sclerosing cholangitis based on the clinical and laboratory findings, as well as the typical imaging features on computed tomography and magnetic resonance (MR) imaging with MR cholangiography. Familiarity with various etiologies of sclerosing cholangitis and awareness of their typical clinical and imaging findings are essential for an accurate diagnosis and appropriate management.

  13. Endoscopic therapy of posttransplant biliary stenoses after right-sided adult living donor liver transplantation.

    PubMed

    Zoepf, Thomas; Maldonado-Lopez, Evelyn J; Hilgard, Philip; Schlaak, Joerg; Malago, Massimo; Broelsch, Christoph E; Treichel, Ulrich; Gerken, Guido

    2005-11-01

    Endoscopic treatment of biliary strictures after liver transplantation is a therapeutic challenge. In particular, outcomes of endoscopic therapy of biliary complications in the case of duct-to-duct anastomosis after living related liver transplantation are limited. The aim of this study was to evaluate the feasibility and success of an endoscopic treatment approach to posttransplant biliary strictures (PTBS) after right-sided living donor liver transplantation (RLDLT) with duct-to-duct anastomosis. Ninety patients who received adult-to-adult RLDLT in our center were screened retrospectively with respect to endoscopic treatment of PTBS. Therapy was judged as successful when cholestasis parameters returned to normal and bile duct narrowing was reduced significantly after the completion of therapy. Forty of 90 RLDLT patients received duct-to-duct anastomosis, 12 (30%) showed PTBS. Seven of 12 patients were treated successfully by endoscopy; the remaining 5 patients were treated primarily by surgery. Most patients were treated by balloon dilatation followed by insertion of endoprostheses. A median of 2.5 dilatation sessions were necessary and the median treatment duration was 8 months. One patient developed endoscopy-treatable recurrent stenosis, no surgical intervention was necessary. Mild pancreatitis occurred in 7.9% and cholangitis in 5.3% of the procedures. One minor bleeding episode occurred during sphincterotomy. Bleeding was managed endoscopically. Endoscopic therapy of adult-to-adult right living related liver transplantation with duct-to-duct anastomosis is feasible and frequently is successful. The duct-to-duct anastomosis offers the possibility of endoscopic treatment. Endoscopic treatment of posttransplant biliary strictures is safe, with a low specific complication rate.

  14. Albumin expression distinguishes bile duct adenomas from metastatic adenocarcinoma.

    PubMed

    Moy, Andrea P; Arora, Kshitij; Deshpande, Vikram

    2016-09-01

    Bile duct adenomas may be difficult to distinguish from metastatic carcinomas, particularly well-differentiated pancreatic ductal adenocarcinoma. Prior studies have evaluated the utility of various immunohistochemical markers, although these markers are notable for low sensitivity and/or specificity. The aim of this study was to investigate the utility of albumin and BRAFV600E expression in distinguishing between metastatic pancreatic adenocarcinoma and bile duct adenoma. We studied 26 bile duct adenomas, three bile duct hamartomas, and 158 pancreatic ductal adenocarcinomas. Branched-chain in-situ hybridization (bISH) for albumin was performed; bISH is based on the branched DNA technology, wherein signal amplification is achieved via a series of sequential steps. Additionally, BRAFV600E immunohistochemistry (IHC) was performed on a subset of cases. Twenty-three of 25 (92%) bile duct adenomas were positive for albumin; 18 (72%) showed diffuse staining, and five showed focal staining (20%), including two challenging examples. Two bile duct hamartomas also stained positively. All pancreatic adenocarcinomas were negative for albumin. Seven of 16 (44%) bile duct adenomas and five of 106 (5%) pancreatic ductal adenocarcinomas were positive for BRAFV600E by IHC. The sensitivity and specificity of expression of albumin, as detected by bISH, for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 92% and 100%, respectively; the sensitivity and specificity of BRAFV600E IHC for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 43.8% and 95.3%, respectively. Diagnostically challenging examples of bile duct adenoma may be distinguished from metastatic pancreatic adenocarcinoma by the use of albumin bISH. © 2016 John Wiley & Sons Ltd.

  15. Postoperative Biliary Leak Treated with Chemical Bile Duct Ablation Using Absolute Ethanol: A Report of Two Cases.

    PubMed

    Sasaki, Maho; Hori, Tomohide; Furuyama, Hiroaki; Machimoto, Takafumi; Hata, Toshiyuki; Kadokawa, Yoshio; Ito, Tatsuo; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Kimura, Yusuke; Takamatsu, Yuichi; Kitano, Taku; Yoshimura, Tsunehiro

    2017-08-08

    BACKGROUND Postoperative bile duct leak following hepatobiliary and pancreatic surgery can be intractable, and the postoperative course can be prolonged. However, if the site of the leak is in the distal bile duct in the main biliary tract, the therapeutic options may be limited. Injection of absolute ethanol into the bile duct requires correct identification of the bile duct, and balloon occlusion is useful to avoid damage to the surrounding tissues, even in cases with non-communicating biliary fistula and bile leak. CASE REPORT Two cases of non-communicating biliary fistula and bile leak are presented; one case following pancreaticoduodenectomy (Whipple's procedure), and one case following laparoscopic cholecystectomy. Both cases were successfully managed by chemical bile duct ablation with absolute ethanol. In the first case, the biliary leak occurred from a fistula of the right posterior biliary tract following pancreaticoduodenectomy. Cannulation of the leaking bile duct and balloon occlusion were achieved via a percutaneous route, and seven ablation sessions using absolute ethanol were required. In the second case, perforation of the bile duct branch draining hepatic segment V occurred following laparoscopic cholecystectomy. Cannulation of the bile duct and balloon occlusion were achieved via a transhepatic route, and seven ablation sessions using absolute ethanol were required. CONCLUSIONS Chemical ablation of the bile duct using absolute ethanol is an effective treatment for biliary leak following hepatobiliary and pancreatic surgery, even in cases with non-communicating biliary fistula. Identification of the bile duct leak is required before ethanol injection to avoid damage to the surrounding tissues.

  16. Performance Analysis of a Modular Small-Diamter Air Distribution System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew; Rudd, Armin

    2016-03-01

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less

  17. The Harderian gland, its secretory duct and porphyrin content in the woodmouse (Apodemus sylvaticus).

    PubMed Central

    Johnston, H S; McGadey, J; Payne, A P; Thompson, G G; Moore, M R

    1987-01-01

    The Harderian gland of the woodmouse (Apodemus sylvaticus) consists of tubules lined by a single layer of epithelial cells with a surrounding layer of myoepithelial cells. The epithelium contains two cell types, one with numerous small, clear, lipid vacuoles (Type I), the other with large electron-dense ones (Type II). Each type is further subdivided into cells where the smooth endoplasmic reticulum exhibits pronounced vacuolation (Ia and IIa). The lipid vacuoles frequently coalesce and are released by exocytosis. They possess a multilamellar cap; similar multilamellar whorls (without a vacuole) are also seen. Polytubular complexes are a feature of Type II cells; tubules are in continuity with the smooth endoplasmic reticulum. Peroxisomes are also present. Fenestrated capillaries occur frequently in the interstitium, and (where no myoepithelial cell intervenes) the basal surface of the gland epithelial cell is covered with microvilli. There is no morphologically distinct duct system within the gland. The extraglandular duct is lined by columnar epithelium except at the opening on to the nictitating membrane where there is stratified squamous epithelium, with melanocytes and nests of mucus-secreting cells. The porphyrin content of the gland is low and solid intraluminal deposits are not seen. Images Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 PMID:3429316

  18. Short-Term Monitoring Results for Advanced New Construction Test House - Roseville, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stecher, D.; Brozyna, K.; Imm, C.

    2013-09-01

    A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft² slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditionedmore » space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.« less

  19. [Obstructed hemivagina and ipsilateral renal anomaly: unusual cause of piocolpos. Report a case and review of literature ].

    PubMed

    Cortés-Contreras, Diana Karen; Juárez-Cruz, Patricio Manuel; Vázquez-Flores, José; Vázquez-Flores, Al David

    2014-10-01

    OHVIRA (Obstructed hemivagina and ipsilateral renal anomaly) by acronym and abbreviations in English or Herlyn Werner Wunderlich syndrome is a rare congenital malformation caused by an alteration in the Mullerian ducts and Wolffian Ducts. Which is characterized by a triad: uterus didelphys, obstructed and ipsilateral renal agenesis hemivagina still uncertain etiology. Patients are usually asymptomatic until menarche where the most common clinical presentation is pelvic pain, followed by a vaginal or abdominal mass, normal menstrual periods, infertility, and vaginal discharge rarely appears. The case of a female patient of 15 years, nubile with chronic fetid vaginal discharge, initially diagnosed and treated as pelvic inflammatory disease occurs, however because it is an exceptional condition with the background of the patient, by complementary studies were conducted where pelvic ultrasound revealed pyocolpos and absence of left kidney, uterus didelphys, blind hemivagina by other imaging studies, where we could integrate Herlyn-Werner-Wunderlich syndrome. In conclusion, abnormalities in the development of the Miillerian ducts are difficult to diagnose early, so you must have the embryological knowledge, conduct thorough clinical assessment and detailed picture in whom the coridition is suspected to identify malformations coexisting urinary tract and vaginal defects with the importance of preserving reproductive success through appropriate planning of surgical approach, given that the fertility rate in these patients is comparable to the average.

  20. [Spontaneous perforation of the hepatic duct during biliary lithiasis complicated by acute pancreatitis].

    PubMed

    Assadourian, R; Chometowski, S; Bourde, J; Poitout, D; Lamy, J

    1975-10-01

    The association of perforation of the common bile duct, cholecystitis and acute pancreatitis, should be emphasized. Physiopathology of perforation of the bile duct may be compared with that of pancreatitis. Repair of the bile duct may be delicate requiring hepatico-jejunostomy on an isolated loop.

  1. 40 CFR 63.11522 - What definitions apply to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ductwork, dampers, manifolds, plenums, or fans designed to draw greater than 85 percent of the airborne... limited to, the following components as applicable to a given capture system design: duct intake devices... designed with single use cartridges, which are removed and disposed after reaching capacity, or continuous...

  2. 40 CFR 63.11522 - What definitions apply to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ductwork, dampers, manifolds, plenums, or fans designed to draw greater than 85 percent of the airborne... limited to, the following components as applicable to a given capture system design: duct intake devices... designed with single use cartridges, which are removed and disposed after reaching capacity, or continuous...

  3. 40 CFR 63.11522 - What definitions apply to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ductwork, dampers, manifolds, plenums, or fans designed to draw greater than 85 percent of the airborne... limited to, the following components as applicable to a given capture system design: duct intake devices... designed with single use cartridges, which are removed and disposed after reaching capacity, or continuous...

  4. 40 CFR 63.11522 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ductwork, dampers, manifolds, plenums, or fans designed to draw greater than 85 percent of the airborne... limited to, the following components as applicable to a given capture system design: duct intake devices... designed with single use cartridges, which are removed and disposed after reaching capacity, or continuous...

  5. 40 CFR 63.11522 - What definitions apply to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ductwork, dampers, manifolds, plenums, or fans designed to draw greater than 85 percent of the airborne... limited to, the following components as applicable to a given capture system design: duct intake devices... designed with single use cartridges, which are removed and disposed after reaching capacity, or continuous...

  6. Cold Spray Technology for DOD Applications

    DTIC Science & Technology

    2012-08-01

    Ducts Bleed Valve Intermediate F-100 Engine F-15 Eagle Materials Ti6Al-4V Inconel Waspalloy Aluminum Problems Cavitation Wear Corrosion...T5 500 --- --- --- --- AZ92A T6 --- --- 765 425 5 ZE41A T5 625 2 --- --- --- M. M. Avedesian, Hugh Baker,"Magnesium and magnesium alloys", Edition

  7. 77 FR 57484 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-18

    ... certain cowl assemblies of the left- and right-hand thrust reversers. This new AD requires removing certain C- duct assemblies of the left- and right-hand thrust reversers from service at certain designated life limits, and also adds airplanes to the applicability. This AD was prompted by new life limits on...

  8. Investigation of the potential of optical coherence tomography (OCT) as a non-invasive diagnostic tool in reproductive medicine

    NASA Astrophysics Data System (ADS)

    Trottmann, Matthias; Homann, Christian; Leeb, R.; Doering, D.; Kuznetsova, J.; Reese, S.; Stief, C. G.; Koelle, S.; Sroka, R.

    2015-02-01

    Introduction and objective: In Europe, nearly every sixth couple in the reproductive age is involuntarily childless. In about 30%, both male and female reveal fertility problems. In about 10% of infertile men, azoospermia is the underlying cause. As conventional therapeutic options are limited, surgical testicular sperm extraction (TESE) is necessary to obtain sperms for assisted reproductive techniques. Regarding the females, up to 30% of all idiopathic infertilities are due to alterations of the uterine tube So far, no imaging technique, which does not require any labelling, is available to evaluate the male and female genital tract at a microscopic level under in vivo conditions. Thus, the aim of this study was to investigate the potential of optical coherence tomography (OCT) as a non-invasive diagnostic tool in gynaecology and andrology. Material and Methods: Tissues samples from the bovine testis, epididymis, vas deferens, ovary, oviduct (ampulla and isthmus) and uterus were obtained immediately after slaughter (14 cows aged 3 to 8 years and 14 bulls aged 3 to 6 years; breeds: Holstein- Friesian, and Deutsches Fleckvieh). Imaging was done by using the US Food and Drug Administration (FDA) approved probe-based Niris Imaging System (Imalux, Cleveland, Ohio, USA) and the Telesto 1325 nm OCT System and Ganymede 930 nm OCT System (Thorlabs Inc., Dachau, Germany). All images obtained were compared to histological images after paraffin embedding and HE staining. Results: OCT imaging visualized the microarchitecture of the testis, epididymis, spermatic duct and the ovary, oviduct and uterus. Using the Thorlabs systems a axial resolution of approx. 5μm and lateral resolution of 8- 15μm could be achieved. Different optical tissue volumes could be visualized, which depends on the optical penetration depth of the wavelength of the system used. While the tissue volume observed by probe based Imalux-OCT is similar to the used Thorlabs systems, the optical resolution is reduced. By means of the microscopic OCT-system differentiation of testical tissue structures like content and diameter of seminiferous tubules and the epididymal duct was possible. Structures of the female oviduct, like the primary, secondary and tertiary folds including the typical epithelium consisting of secretory and ciliated cells were identified. Ampulla and isthmus were clearly differentiated by the height of the folds and the thickness of the smooth muscle layer. Imaging was successful both from the outside wall and from the inner lumen. After experience with microscopic OCT-structure identification such structures could also be identified by means of probe based OCT. Conclusions: Technical improvement of probe-based OCT up to a high-resolution level of nowadays-available OCT microscopic systems could open up new ways of in vivo imaging in the reproductive tract. Potential applications could be an OCT-guided testicular biopsy for improving sperm retrieval or microscopic evaluation of the oviduct by OCT-assisted fertiloscopy. The latter would provide a valuable tool to facilitate the decision of which type of assisted reproductive techniques might be preferred.

  9. [A photo-optical observation of gallbladder motility in dogs (author's transl)].

    PubMed

    Kudo, N

    1976-03-01

    A photo-optical observation on gallbladder motility was made with the 16 mm cine-cholangiography. The subjects studied were thirty two mongrel dogs. The gallbladder was exposed by a short upper midline abdominal incision under pentothal anesthesia. Gallbladder bile was aspirated and contrast medium was given into the bladder, through a transhepatic route. The cine-cholangiography was done by an image intensifier at a speed of one frame every 2 to 4 seconds. The cinefilms taken were observed repeatedly by the screen projection at various speeds. The drawings were made by tracing the outline of the image of the gallbladder on each frame and were overlapped. Moreover, a contraction curve was made by the cholecystometry using of film motion analyzer in every case. At the same time bile flow into the duodenum was recorded to study a relationship between the gallbladder contraction and motility of the terminal common bile duct. The results obtained are as follows: 1. In a resting state any contraction of the gallbladder was not seen during 30 minutes, and a peristalsis-like movements of the neck portion was observed. However, there was not a relationship between the contraction curve of the gallbladder and the bile flow into the duodenum. 2. Immediately after giving Caerulein, the contrast medium injected into the gallbladder was rapidly discharged into the common bile duct by a peristalsis-like movement of the neck. The size of the gallbladder was markedly decreased into three fifths of the initial state three minutes after administration. At the same time contrast medium was continuously discharged into the duodenum. 3. After giving pilocarpine a marked contraction with forceful movement of the neck and body was observed, and the size of the gallbladder was decreased into three quarters ot the initial state. Bile discharge into the duodenum was markedly increased with an active open- and closing movement of the terminal common bile duct.

  10. Evaluation of a ducted-fan power plant designed for high output and good cruise fuel economy

    NASA Technical Reports Server (NTRS)

    Behun, M; Rom, F E; Hensley, R V

    1950-01-01

    Theoretical analysis of performance of a ducted-fan power plant designed both for high-output, high-altitude operation at low supersonic Mach numbers and for good fuel economy at lower fight speeds is presented. Performance of ducted fan is compared with performance (with and without tail-pipe burner) of two hypothetical turbojet engines. At maximum power, the ducted fan has propulsive thrust per unit of frontal area between thrusts obtained by turbojet engines with and without tail-pipe burners. At cruise, the ducted fan obtains lowest thrust specific fuel consumption. For equal maximum thrusts, the ducted fan obtains cruising flight duration and range appreciably greater than turbojet engines.

  11. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    PubMed

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  12. Laser velocimeter and total pressure measurements in circular-to-rectangular transition ducts

    NASA Technical Reports Server (NTRS)

    Patrick, William P.; Mccormick, Duane C.

    1988-01-01

    A comprehensive set of total pressure and three-component laser velocimetry (LV) data were obtained within two circular-to-rectangular transition ducts at low subsonic speeds. This set of reference data was acquired for use in identifying secondary flow mechanisms and for assessing the accuracy of computational procedures for calculating such flows. Data were obtained at the inlet and exit planes of an aspect ratio three duct having a length-to-diameter ratio of one (AR310) and an aspect ratio six duct having a length-to-diameter ratio of three (AR630). Each duct was unseparated throughout its transition section. It is therefore concluded that secondary flows can play an important part in the fluid dynamics of transition ducts and needs to be addressed in computational analysis. The strength of the secondary flows depends on both the aspect ratio and relative axial duct length.

  13. Bortezomib in Treating Patients With Unresectable Locally Advanced or Metastatic Adenocarcinoma of the Bile Duct or Gallbladder

    ClinicalTrials.gov

    2017-06-13

    Adenocarcinoma of the Extrahepatic Bile Duct; Adenocarcinoma of the Gallbladder; Advanced Adult Primary Liver Cancer; Gastrointestinal Cancer; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer

  14. Erlotinib in Treating Patients With Unresectable Liver, Bile Duct, or Gallbladder Cancer

    ClinicalTrials.gov

    2013-06-03

    Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer

  15. Iatrogenic salivary duct injury in head and neck cancer patients: Report of four cases and review of the literature

    PubMed Central

    Kulyapina, Alena; Ochandiano-Caicoya, Santiago; Navarro-Cuellar, Carlos; Navarro-Vila, Carlos

    2014-01-01

    Introduction: The lesions of the salivary ducts may be idiopathic, post- traumatic, or iatrogenic and lead to sialocele formation with persistent painful facial swelling or cutaneous fistula formation. No consensus on treatment of this condition exists: the options of treatment include needle aspiration, pressure dressings, antisialogogue therapy, radiotherapy, botulinum toxin and surgical approaches as duct repair, diversion, ligation, different drainage systems and even parotidectomy/submaxilectomy. The management and special features of iatrogenic salivary duct injury in patients with oral cancer who underwent head and neck reconstructive surgery has not been described yet. Material and Methods: We present four cases of iatrogenic lesions of salivary ducts and its management in patients with oral cancer. Conclusions: The iatrogenic lesions of salivary ducts are to be taken into account in patients with oral cancer as the distal ends of salivary ducts could be involved in the margins of surgical resection. Different options of treatment of this complication are described. Key words:Sialocele, oral cancer, salivary duct. PMID:25136433

  16. Developing flow in S-shaped ducts. 2: Circular cross-section duct

    NASA Technical Reports Server (NTRS)

    Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.

    1984-01-01

    Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.

  17. Development of a cylindrical diffusing optical fiber probe for pancreatic cancer therapy

    NASA Astrophysics Data System (ADS)

    Lee, Sangyeob; Park, Gaye; Park, Jihoon; Yu, Sungkon; Ha, Myungjin; Jang, Seulki; Ouh, Chihwan; Jung, Changhyun; Jung, Byungjo

    2017-02-01

    Although the patients with cancer on pancreas or pancreaticobiliary duct have been increased, it is very difficult to detect and to treat the pancreatic cancer because of its low accessibility and obtuseness. The pancreatic cancer has been diagnosed using ultrasonography, blood test, CT, endoscopic retrograde cholangiopancreatography (ERCP), endoscopic ultrasonography (EUS) and etc. Normally, light can be delivered to the target by optical fibers through the ERCP or EUS. Diffusing optical fibers have been developed with various methods. However, many of them have mechanical and biological problems in the use of small-bend-radius apparatus or in tissue area. This study developed a therapeutic cylindrical diffusing optical fiber probe (CDOFP) for ERCP and EUS which has moderate flexibility and solidity to treat the cancer on pancreaticobiliary duct or pancreas. The CDOFP consists of a biocompatible Teflon tube and multimode glass fiber which has diffusing area processed with laser and high refractive index resin. The CDOFP was characterized to investigate the clinical feasibility and other applications of light therapy using diffusing optical fiber. The results presented that the CDOFP may be used in clinic by combining with endoscopic method, such as ERCP or EUS, to treat cancer on pancreas and pancreaticobiliary duct.

  18. Experimental investigation of turbulent flow through a circular-to-rectangular transition duct. Ph.D. Thesis - Washington Univ.

    NASA Technical Reports Server (NTRS)

    Davis, David O.

    1991-01-01

    Steady, incompressible, turbulent, swirl-free flow through a circular-to-rectangular transition duck was studied experimentally. The cross-sectional area remains the same at the exit as at the inlet, but varies through the transition section to a maximum value approximately 15 percent above the inlet value. The cross-sectional geometry everywhere along the duct is defined by the equation of a superellipse. Mean and turbulence data were accumulated utilizing pressure and hot-wire instrumentation at five stations along the test section. Data are presented for operating bulk Reynolds numbers of 88,000 and 390,000. Measured quantities include total and static pressure, the three components of the mean velocity vector, and the six components of the Reynolds stress tensor. In addition to the transition duct measurements, a hot-wire technique which relies on the sequential use of single rotatable normal and slant-wire probes was proposed. The technique is applicable for measurement of the total mean velocity vector and the complete Reynolds stress tensor when the primary flow is arbitrarily skewed relative to a plane which lies normal to the probe axis of rotation.

  19. Time-Dependent Parabolic Finite Difference Formulation for Harmonic Sound Propagation in a Two-Dimensional Duct with Flow

    NASA Technical Reports Server (NTRS)

    Kreider, Kevin L.; Baumeister, Kenneth J.

    1996-01-01

    An explicit finite difference real time iteration scheme is developed to study harmonic sound propagation in aircraft engine nacelles. To reduce storage requirements for future large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable for a harmonic monochromatic sound field, a parabolic (in time) approximation is introduced to reduce the order of the governing equation. The analysis begins with a harmonic sound source radiating into a quiescent duct. This fully explicit iteration method then calculates stepwise in time to obtain the 'steady state' harmonic solutions of the acoustic field. For stability, applications of conventional impedance boundary conditions requires coupling to explicit hyperbolic difference equations at the boundary. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

  20. The Propagation and Scattering of EM Waves in Electrically Large Ducts

    NASA Astrophysics Data System (ADS)

    Khan, Saeed Mahmood

    The electromagnetic scattering from large arbitrarily shaped ducts with complex termination is studied here by a hybrid technique. The propagation of electromagnetic waves in the duct is analyzed in terms of an approximate modal solution. A finite difference technique is employed for computing the reflection characteristics of the complex terminations. Both solutions are combined using the unimoment method. The analysis here is carried out for monostatic RCS and considers only fields backscattered from inside the cavity. Rim-diffraction has been left out. The procedure offers such advantages as in that it is not necessary to find complicated Green's functions, which may not be readily available, when compared with the integral equation method. Hybridization performed by combining an approximate modal technique with a finite difference one makes the scheme numerically efficient. From a computational EM point of view, it brings together a whole spectrum of techniques associated with high frequency modal analysis, Fourier Methods, Radar Cross Section and Scattering, finite difference solution and the Unimoment Method. The practical application of this technique may range from the study of RCS scattered from jet inlets of radar evasive aircraft to submarine communication waveguides.

Top