[ENDOSONOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF THE COMMON BILE DUCT STENOSIS].
Solodinina, E N; Starkov, Y G; Shumkin, L V
2015-01-01
The article states the results of examination and treatment of 57 patients with stenosis of the common bile duct of various genesis. The main aim of the work is criteria definition and evaluation of diagnostic significance of endosonography in the differential diagnosis of benign and malignant common bile duct stenosis. The paper presents a methodology of endoscopic ultrasound and basic criteria for the differential diagnosis of tumors and other lesions of the extrahepatic bile ducts. A comparative analysis of endosonography, ultrasound, CT, MRCP was conducted. The sensitivity of endosonography in determining the nature of the common bile duct stenosis was 97.7%, a specificity 100% and accuracy 98.2%, which is superior to other methods of radiological diagnosis. In comprehensive surgical centers endosonography should be used as a method of specifying the final diagnosis to determine the nature of the common bile duct stenosis, particularly at low constriction location.
Morais Pérez, D
2004-01-01
The duct of the parotid gland had been indiscriminately named Stenon's duct or Stensen's duct. In order to establish its origin we carried out a biographic search and a brief revision of the life of the great anatomist, geologist, palaeontologist, bishop and finally Saint Nicolaus Stensen.
NASA Astrophysics Data System (ADS)
Kawase, Kodo; Tripathi, Saroj R.
2016-03-01
Recently, some studies reported that the sweat ducts act as a low-Q-factor helical antenna due to their helical structure, and resonate in the terahertz frequency range according to their structural parameters. According to the antenna theory, when the duct works as a helical antenna, the dimension of the helix plays a key role to determine the frequency of resonance. Therefore, the accurate determination of structural parameters of sweat duct is crucially important to obtain the reliable frequency of resonance and modes of operations. Therefore, here we performed the optical coherence tomography (OCT) of human subjects on their palm and foot to investigate the density, distribution and morphological features of sweat ducts. Moreover, we measured the dielectric properties of stratum corneum using terahertz time domain spectroscopy and based upon this information, we determined the frequency of resonance. We recruited 32 subjects for the measurement and the average duct diameter was 95±11μm. Based upon this information on diameter of duct and THz dielectric properties of stratum corneum (ɛ=5.1±1.3), we have calculated the frequency of resonance of sweat duct. Finally, we determined that the center frequency of resonance was 442±76 GHz. We believe that these findings will facilitate further investigation of the THz-skin interaction and provide guidelines for safety levels with respect to human exposure. We will also report on the EEG measurement while being shined by micro watt order THz waves.
Combustor assembly in a gas turbine engine
Wiebe, David J; Fox, Timothy A
2013-02-19
A combustor assembly in a gas turbine engine. The combustor assembly includes a combustor device coupled to a main engine casing, a first fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner disposed radially inwardly from the flow sleeve. The first fuel injection system provides fuel that is ignited with the pressurized air creating first working gases. The intermediate duct is disposed between the liner and the transition duct and defines a path for the first working gases to flow from the liner to the transition duct. An intermediate duct inlet portion is associated with a liner outlet and allows movement between the intermediate duct and the liner. An intermediate duct outlet portion is associated with a transition duct inlet section and allows movement between the intermediate duct and the transition duct.
The Primary Duct of Bothrops jararaca Glandular Apparatus Secretes Toxins
Sakai, Fernanda; Portes-Junior, José Antonio; Godoy Viana, Luciana; Mendes Carneiro, Sylvia; Perales, Jonas; Yamanouye, Norma
2018-01-01
Despite numerous studies concerning morphology and venom production and secretion in the main venom gland (and some data on the accessory gland) of the venom glandular apparatus of Viperidae snakes, the primary duct has been overlooked. We characterized the primary duct of the Bothrops jararaca snake by morphological analysis, immunohistochemistry and proteomics. The duct has a pseudostratified epithelium with secretory columnar cells with vesicles of various electrondensities, as well as mitochondria-rich, dark, basal, and horizontal cells. Morphological analysis, at different periods after venom extraction, showed that the primary duct has a long cycle of synthesis and secretion, as do the main venom and accessory glands; however, the duct has a mixed mode venom storage, both in the lumen and in secretory vesicles. Mouse anti-B. jararaca venom serum strongly stained the primary duct’s epithelium. Subsequent proteomic analysis revealed the synthesis of venom toxins—mainly C-type lectin/C-type lectin-like proteins. We propose that the primary duct’s toxin synthesis products complement the final venom bolus. Finally, we hypothesize that the primary duct and the accessory gland (components of the venom glandular apparatus) are part of the evolutionary path from a salivary gland towards the main venom gland. PMID:29533989
Finding Infrastructure with Non-Destructive Imaging Technologies (FINDIT)
NASA Astrophysics Data System (ADS)
Tuckwell, G.; Usher, C.; Stringfellow, M.; Chapman, D.; Metje, N.; Roberts, D.
2017-12-01
Novel uses for existing technologies and new post-processing techniques have been developed to generate a level and detail of information that will make a step-change to standard practice in mapping and assessing the condition of buried infrastructure. The most appropriate sensing technologies for buried telecommunications ducts have been identified as Ground Penetrating Radar and Acoustic reflectometry. Dielectric permittivity changes in the near-surface can manifest themselves in different ways within GPR data. Numerical modelling work has been undertaken by applying a Kuepper signal and an exploding source, and using various different frequencies to determine minute changes (e.g. cracks in pipes) in an object or feature within the near surface. This modelling demonstrated that there is a clear difference between an empty duct, a duct partially filled with cables and a damaged duct. This was confirmed in a laboratory test on dry sand to determine the detectability of a hole in a plastic pipe. This has formed the foundation new data processing algorithms to detect the presence of such defects in real and synthetic data sets. Future work will focus on the development of a test site and field trials to assess the detectability of defects under realistic field conditions. This ongoing programme of work will be validated and iteratively improved by field trials under controlled and live commercial conditions. Finally the cost/benefit of the new workflows develop evaluated through the development of business models for the application of such techniques in telecoms, water and energy supply sectors. In the UK, the majority of the communication network is buried in ducts which are often several decades old. They have often collapsed or become blocked so that spare capacity cannot be used. There is currently no surface detection technology which can accurately locate the position of these defects (or even accurately locate the ducts in all circumstances), so time consuming and costly manual rodding is performed which cannot detect subsequent blockages, resulting in inadequate and inefficient repair planning, increasing the costs and causing disruption to road users.
Experiments in Sound and Structural Vibrations Using an Air-Analog Model Ducted Propulsion System
2007-08-01
Department of Aerospace S~and Mechanical Engineering I 20070904056 I EXPERIMENTS IN SOUND AND STRUCTURAL VIBRATIONS USING AN AIR -ANALOG MODEL DUCTED...SOUND AND STRUCTURAL * VIBRATIONS USING AN AIR -ANALOG MODEL DUCTED PROPULSION SYSTEM FINAL TECHNICAL REPORT Prepared by: Scott C. Morris Assistant...Vibration Using Air - 5b. GRANT NUMBER Analog Model Ducted Propulsion Systems N00014-1-0522 5C. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER
Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.
Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru
2015-01-01
A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.
Cholangiocarcinoma in a middle-aged patient working at a printing plant.
Tanaka, Shogo; Fukumoto, Nobusuke; Ohno, Kohichi; Tanaka, Sayaka; Ohsawa, Masahiko; Yamamoto, Takatsugu; Nakanuma, Yasuni; Kuboo, Shoji
2014-06-01
A 39-year-old male with elevated serum transferases consulted our hospital in September 2010. Since 1999, he had worked at a printing company using organic solvents. Cholangiography revealed stenosis of the left hepatic duct with peripheral dilation, stricture of the right hepatic duct, and irregularity of the extrahepatic bile duct. As a preoperative diagnosis of sclerosing cholangitis and cholangiocarcinoma was made, extended left hepatectomy with resection of the extrahepatic bile duct and anastomosis of the anterior and posterior branches of the bile duct and the jejunum (Roux-en Y reconstruction) were performed. A histological examination showed papillary carcinoma of the medial hepatic bile duct with intraductal growth, and biliary intraepithelial neoplasia-2/3 lesions from the medial hepatic bile duct to the right hepatic and the common bile ducts. Chronic cholangitis was shown around the tumors. Postoperatively, the patient was treated with adjuvant chemo-radiation, and he is doing well 30 months after the operation, without recurrence. Unknown causes, including exposure to organic solvents, might have induced chronic bile duct injury and contributed to the development of cholangiocarcinoma.
Terrat, Yves; Biass, Daniel; Dutertre, Sébastien; Favreau, Philippe; Remm, Maido; Stöcklin, Reto; Piquemal, David; Ducancel, Frédéric
2012-01-01
Although cone snail venoms have been intensively investigated in the past few decades, little is known about the whole conopeptide and protein content in venom ducts, especially at the transcriptomic level. If most of the previous studies focusing on a limited number of sequences have contributed to a better understanding of conopeptide superfamilies, they did not give access to a complete panorama of a whole venom duct. Additionally, rare transcripts were usually not identified due to sampling effect. This work presents the data and analysis of a large number of sequences obtained from high throughput 454 sequencing technology using venom ducts of Conus consors, an Indo-Pacific living piscivorous cone snail. A total of 213,561 Expressed Sequence Tags (ESTs) with an average read length of 218 base pairs (bp) have been obtained. These reads were assembled into 65,536 contiguous DNA sequences (contigs) then into 5039 clusters. The data revealed 11 conopeptide superfamilies representing a total of 53 new isoforms (full length or nearly full-length sequences). Considerable isoform diversity and major differences in transcription level could be noted between superfamilies. A, O and M superfamilies are the most diverse. The A family isoforms account for more than 70% of the conopeptide cocktail (considering all ESTs before clustering step). In addition to traditional superfamilies and families, minor transcripts including both cysteine free and cysteine-rich peptides could be detected, some of them figuring new clades of conopeptides. Finally, several sets of transcripts corresponding to proteins commonly recruited in venom function could be identified for the first time in cone snail venom duct. This work provides one of the first large-scale EST project for a cone snail venom duct using next-generation sequencing, allowing a detailed overview of the venom duct transcripts. This leads to an expanded definition of the overall cone snail venom duct transcriptomic activity, which goes beyond the cysteine-rich conopeptides. For instance, this study enabled to detect proteins involved in common post-translational maturation and folding, and to reveal compounds classically involved in hemolysis and mechanical penetration of the venom into the prey. Further comparison with proteomic and genomic data will lead to a better understanding of conopeptides diversity and the underlying mechanisms involved in conopeptide evolution. Copyright © 2011 Elsevier Ltd. All rights reserved.
Causes and Prevention of Laparoscopic Bile Duct Injuries
Way, Lawrence W.; Stewart, Lygia; Gantert, Walter; Liu, Kingsway; Lee, Crystine M.; Whang, Karen; Hunter, John G.
2003-01-01
Objective To apply human performance concepts in an attempt to understand the causes of and prevent laparoscopic bile duct injury. Summary Background Data Powerful conceptual advances have been made in understanding the nature and limits of human performance. Applying these findings in high-risk activities, such as commercial aviation, has allowed the work environment to be restructured to substantially reduce human error. Methods The authors analyzed 252 laparoscopic bile duct injuries according to the principles of the cognitive science of visual perception, judgment, and human error. The injury distribution was class I, 7%; class II, 22%; class III, 61%; and class IV, 10%. The data included operative radiographs, clinical records, and 22 videotapes of original operations. Results The primary cause of error in 97% of cases was a visual perceptual illusion. Faults in technical skill were present in only 3% of injuries. Knowledge and judgment errors were contributory but not primary. Sixty-four injuries (25%) were recognized at the index operation; the surgeon identified the problem early enough to limit the injury in only 15 (6%). In class III injuries the common duct, erroneously believed to be the cystic duct, was deliberately cut. This stemmed from an illusion of object form due to a specific uncommon configuration of the structures and the heuristic nature (unconscious assumptions) of human visual perception. The videotapes showed the persuasiveness of the illusion, and many operative reports described the operation as routine. Class II injuries resulted from a dissection too close to the common hepatic duct. Fundamentally an illusion, it was contributed to in some instances by working too deep in the triangle of Calot. Conclusions These data show that errors leading to laparoscopic bile duct injuries stem principally from misperception, not errors of skill, knowledge, or judgment. The misperception was so compelling that in most cases the surgeon did not recognize a problem. Even when irregularities were identified, corrective feedback did not occur, which is characteristic of human thinking under firmly held assumptions. These findings illustrate the complexity of human error in surgery while simultaneously providing insights. They demonstrate that automatically attributing technical complications to behavioral factors that rely on the assumption of control is likely to be wrong. Finally, this study shows that there are only a few points within laparoscopic cholecystectomy where the complication-causing errors occur, which suggests that focused training to heighten vigilance might be able to decrease the incidence of bile duct injury. PMID:12677139
Advanced in-duct sorbent injection for SO{sub 2} control. Final technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stouffer, M.R.; Withium, J.A.; Rosenhoover, W.A.
1994-12-01
The objective of this research project was to develop a second generation duct sorbent injection technology as a cost-effective compliance option for the 1990 Clean Air Act Amendments. Research and development work was focused on the Advanced Coolside process, which showed the potential for exceeding the original performance targets of 90% SO{sub 2} removal and 60% sorbent utilization. Process development was conducted in a 1000 acfm pilot plant. The pilot plant testing showed that the Advanced Coolside process can achieve 90% SO{sub 2} removal at sorbent utilizations up to 75%. The testing also showed that the process has the potentialmore » to achieve very high removal efficiency (90 to >99%). By conducting conceptual process design and economic evaluations periodically during the project, development work was focused on process design improvements which substantially lowered process capital and operating costs, A final process economic study projects capital costs less than one half of those for limestone forced oxidation wet FGD. Projected total SO{sub 2} control cost is about 25% lower than wet FGD for a 260 MWe plant burning a 2.5% sulfur coal. A waste management study showed the acceptability of landfill disposal; it also identified a potential avenue for by-product utilization which should be further investigated. Based on the pilot plant performance and on the above economic projections, future work to scale up the Advanced Coolside process is recommended.« less
On Computations of Duct Acoustics with Near Cut-Off Frequency
NASA Technical Reports Server (NTRS)
Dong, Thomas Z.; Povinelli, Louis A.
1997-01-01
The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.
MHD work related to a self-cooled Pb-17Li blanket with poloidal-radial-toroidal ducts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reimann, J.; Barleon, L.; Buehler, L.
1994-12-31
For self cooled liquid metal blankets MHD pressure drop and velocity distributions are considered as critical issues. This paper summarizes MHD work performed for a DEMO-relevant Pb-17Li blanket which uses essential characteristics of a previous ANL design: The coolant flows downwards in the rear poloidal ducts, turns by 180{degrees} at the blanket bottom and is distributed from the ascending poloidal ducts into short radial channels which feed the toroidal First Wall coolant ducts (aligned with the main magnetic field direction). The flow through the subsequent radial channels is collected again in poloidal channels and the coolant leaves the blanket segmentmore » at the top. The blanket design is based on the use of flow channel inserts (FCIs) (which means electrically thin conducting walls for MHD) for all ducts except for the toroidal FW coolant channels. MHD related issues were defined and estimations of corresponding pressure drops were performed. Previous experimental work included a proof of principle of FCIs and a detailed experiment with a single {open_quotes}poloidal{sm_bullet}toroidal{sm_bullet}poloidal{close_quotes} duct (cooperation with ANL). In parallel, a numerical code based on the Core Flow Approximation (CFA) was developed to predict pressure drop and velocity distributions for arbitrary single duct geometries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beal, D.; McIlvaine , J.; Fonorow, K.
2011-11-01
This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition tomore » enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.« less
HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant
2016-09-01
material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is
CFD transient simulation of an isolator shock train in a scramjet engine
NASA Astrophysics Data System (ADS)
Hoeger, Troy Christopher
For hypersonic flight, the scramjet engine uses an isolator to contain the pre-combustion shock train formed by the pressure difference between the inlet and the combustion chamber. If this shock train were to reach the inlet, it would cause an engine unstart, disrupting the flow through the engine and leading to a loss of thrust and potential loss of the vehicle. Prior to this work, a Computational Fluid Dynamics (CFD) simulation of the isolator was needed for simulating and characterizing the isolator flow and for finding the relationship between back pressure and changes in the location of the leading edge of the shock train. In this work, the VULCAN code was employed with back pressure as an input to obtain the time history of the shock train leading location. Results were obtained for both transient and steady-state conditions. The simulation showed a relationship between back-to-inlet pressure ratios and final locations of the shock train. For the 2-D runs, locations were within one isolator duct height of experimental results while for 3-D runs, the results were within two isolator duct heights.
Scheuermann, Uwe; Widyaningsih, Rizky; Hoppe-Lotichius, Maria; Heise, Michael; Otto, Gerd
2016-06-01
The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and multivariate analyses of 18 clinicopathological parameters revealed that patient age, serum alkaline phosphatase, tumour marker CA19-9 and presence of tumour mass in computed tomography were independent predictors for malignant biliary stenoses (p < 0.05). Receiver operator characteristic curve showed that a CA19-9 serum level of 61.2 U/ml or more has a sensitivity, specificity and diagnostic accuracy for predicting the malignant nature of the hilar biliary stenoses of 74.6%, 80.0% and 83.5%, respectively. Surgical resection could be avoided by preoperative work-up and surgical exploration in 10 out of 34 patients with benign lesions. Rates of major liver resections performed were 66.7% in the benign lesion group and 90.7% in the Klatskin tumour group. Despite improvements of preoperative diagnostics, it remains difficult to differentiate between benign and malignant hilar bile duct stenosis. Even explorative laparotomy was not able to safely exclude Klatskin tumour in all cases and therefore major liver resection was inevitable.
Generation of Higher Order Modes in a Rectangular Duct
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Cabell, Randolph H.; Brown, Donald E.
2004-01-01
Advanced noise control methodologies to reduce sound emission from aircraft engines take advantage of the modal structure of the noise in the duct. This noise is caused by the interaction of rotor wakes with downstream obstructions such as exit guide vanes. Mode synthesis has been accomplished in circular ducts and current active noise control work has made use of this capability to cancel fan noise. The goal of the current effort is to examine the fundamental process of higher order mode propagation through an acoustically treated, curved duct. The duct cross-section is rectangular to permit greater flexibility in representation of a range of duct curvatures. The work presented is the development of a feedforward control system to generate a user-specified modal pattern in the duct. The multiple-error, filtered-x LMS algorithm is used to determine the magnitude and phase of signal input to the loudspeakers to produce a desired modal pattern at a set of error microphones. Implementation issues, including loudspeaker placement and error microphone placement, are discussed. Preliminary results from a 9-3/8 inch by 21 inch duct, using 12 loudspeakers and 24 microphones, are presented. These results demonstrate the ability of the control system to generate a user-specified mode while suppressing undesired modes.
Development of Explosive Ripper with Two-Stage Combustion
1974-10-01
inch pipe duct work, the width of this duct proved to be detrimental in marginally rippable material; the duct, instead of the penetrator tip, was...marginally rippable rock. ID. Operating Requirements 2. Fuel The two-stage combustion device is designed to operate using S A 42. the same diesel
Characterization of the secondary flow in hexagonal ducts
Marin, O.; Vinuesa, R.; Obabko, A. V.; ...
2016-12-06
In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Re τ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondarymore » flow integrated over the cross-sectional area < K > yz decreases with Re in the hexagon, whereas it remains constant with Re in square ducts at comparable Reynolds numbers. Close connection between the values of Reynolds stress uw¯ on the horizontal wall close to the corner and the interaction of bursting events between the horizontal and inclined walls is found. This interaction leads to the formation of the secondary flow, and is less frequent in the hexagon as Re increases due to the 120° aperture of its vertex, whereas in the square duct the 90° corner leads to the same level of interaction with increasing Re. Analysis of turbulence statistics at the centerplane and the azimuthal variance of the mean flow and the fluctuations shows a close connection between hexagonal ducts and pipe flows, since the hexagon exhibits near-axisymmetric conditions up to a distance of around 0.15 DH measured from its center. Spanwise distributions of wall-shear stress show that in square ducts the 90° corner sets the location of a high-speed streak at a distance z + v≃50 from it, whereas in hexagons the 120° aperture leads to a shorter distance of z + v≃38. Finally, at these locations the root mean square of the wall-shear stresses exhibits an inflection point, which further shows the connections between the near-wall structures and the large-scale motions in the outer flow.« less
Solodinina, E N; Starkov, Iu G; Shumkina, L V
2016-01-01
To define criteria and to estimate diagnostic significance of endosonography in differential diagnosis of benign and malignant stenoses of common bile duct. We presented the results of survey and treatment of 57 patients with benign and malignant stenoses of common bile duct. The technique of endosonography is described. We have formulated major criteria of differential diagnostics of tumoral and non-tumoral lesion of extrahepatic bile ducts. Comparative analysis of endosonography, ultrasound, computed tomography and magnetic resonance cholangiopancreatography was performed. Sensitivity, specificity and accuracy of endosonography in diagnosis of stenosis cause is 97.7%, 100% and 98.2% respectively. So it exceeds the efficacy of other diagnostic X-ray methods. In modern surgical clinic endosonography should be mandatory performed. It is necessary for final diagnostics of cause of common bile duct stenosis especially in case of its low location.
The Development of the Ducted Fan Noise Propagation and Radiation Code CDUCT-LaRC
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Farassat, F.; Pope, D. Stuart; Vatsa, Veer
2003-01-01
The development of the ducted fan noise propagation and radiation code CDUCT-LaRC at NASA Langley Research Center is described. This code calculates the propagation and radiation of given acoustic modes ahead of the fan face or aft of the exhaust guide vanes in the inlet or exhaust ducts, respectively. This paper gives a description of the modules comprising CDUCT-LaRC. The grid generation module provides automatic creation of numerical grids for complex (non-axisymmetric) geometries that include single or multiple pylons. Files for performing automatic inviscid mean flow calculations are also generated within this module. The duct propagation is based on the parabolic approximation theory of R. P. Dougherty. This theory allows the handling of complex internal geometries and the ability to study the effect of non-uniform (i.e. circumferentially and axially segmented) liners. Finally, the duct radiation module is based on the Ffowcs Williams-Hawkings (FW-H) equation with a penetrable data surface. Refraction of sound through the shear layer between the external flow and bypass duct flow is included. Results for benchmark annular ducts, as well as other geometries with pylons, are presented and compared with available analytical data.
Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC
NASA Astrophysics Data System (ADS)
Shin, Hyun-Joon; Lee, Jong-Seung; Lee, Kang-Hoon; Han, Myung-Ryun; Hur, Eui-Beom; Shin, Sung-Chul
2013-09-01
This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.
LLNL's Diagram of Chronological Events and B695 Weekly Inspection Reports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salvo, V
Activities leading to the incident were: (1) RCRA Class 2 Permit Modification granted on July 25, 2007 to install a walk-in fume hood in room 1025; (2) USQ-695-07-148 to do the work approved on 9/17; (3) ducting removed early October done by Facility Personnel under IWS 10331.09; (4) ducting swiped for 'free release' radioactivity only by team 1 personnel on 10/16; (5) all ducting and valves remained in building 695 room 1025 except for one piece delivered to building 391 (MMED shop); (6) material delivered by facility personnel to MMED shope B391 on about 10/19; (7) MMED personnel took amore » duct piece to B511 shop and removed the flange which went to salvage; (8) MMED personnel took the duct piece back to B391 shop and welded on a cap; (9) RHWM personnel picked up the welded duct from B391 around 10/26 and returned ti to B695 room 1025; and (10) the analysis report receive don 12/3 indicated that beryllium swipes take on 11/16, in B695 room 1025, and on ducting that did not leave the room where personnel worked, were above the release level for beryllium.« less
NASA Astrophysics Data System (ADS)
Nikitin, Pavel Viktorovich
2002-01-01
A typical HVAC duct system is a network of interconnected hollow metal pipes which can serve as waveguides and carry electromagnetic waves. This work presents an analysis of this system as a radio frequency communication channel. Two main parts of the analysis include channel modelling and antenna design. The propagation modelling approach used here is based on the waveguide mode theory and employs the transfer matrix method to describe propagation through various cascaded HVAC elements. This allows one to model the channel response in the frequency domain. Impulse response characteristics of the ducts are also analyzed in this work. The approximate transfer matrices of cylindrical straight sections, bends, and tapers are derived analytically. The transforming properties of cylindrical T-junctions are analyzed experimentally. Antenna designs in waveguides and free-space are different. In waveguides, mode excitation characteristics are important as well as the impedance match. The criteria for antenna design in waveguides are presented here. Antennas analyzed in this work are monopole antennas, dipole antennas, and antenna arrays. The developed model can predict both channel response and antenna characteristics for a given geometry and dimensions of the duct system and the antennas. The model is computationally efficient and can potentially be applied to duct systems of multiple story buildings. The accuracy of the model has been validated with extensive experimental measurements on real HVAC ducts.
40 CFR 63.344 - Performance test requirements and test methods.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pressure as follows: (i) Locate a velocity traverse port in a section of straight duct that connects the hooding on the plating tank or tanks with the control device. The port shall be located as close to the..., appendix A). If 2.5 diameters of straight duct work does not exist, locate the port 0.8 of the duct...
40 CFR 63.344 - Performance test requirements and test methods.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pressure as follows: (i) Locate a velocity traverse port in a section of straight duct that connects the hooding on the plating tank or tanks with the control device. The port shall be located as close to the..., appendix A). If 2.5 diameters of straight duct work does not exist, locate the port 0.8 of the duct...
The acoustics of ducted propellers
NASA Astrophysics Data System (ADS)
Ali, Sherif F.
The return of the propeller to the long haul commercial service may be rapidly approaching in the form of advanced "prop fans". It is believed that the advanced turboprop will considerably reduce the operational cost. However, such aircraft will come into general use only if their noise levels meet the standards of community acceptability currently applied to existing aircraft. In this work a time-marching boundary-element technique is developed, and used to study the acoustics of ducted propeller. The numerical technique is developed in this work eliminated the inherent instability suffered by conventional approaches. The methodology is validated against other numerical and analytical results. The results show excellent agreement with the analytical solution and show no indication of unstable behavior. For the ducted propeller problem, the propeller is modeled by a rotating source-sink pairs, and the duct is modeled by rigid annular body of elliptical cross-section. Using the model and the developed technique, the effect of different parameters on the acoustic field is predicted and analyzed. This includes the effect of duct length, propeller axial location, and source Mach number. The results of this study show that installing a short duct around the propeller can reduce the noise that reaches an observer on a side line.
Analyses of radiation impedances of finite cylindrical ducts
NASA Astrophysics Data System (ADS)
Shao, W.; Mechefske, C. K.
2005-08-01
To aid in understanding the characteristics of acoustic radiation from finite cylindrical ducts with infinite flanges, mathematical expressions of generalized radiation impedances at the open ends have been developed. Newton's method is used to find the complex wavenumbers of radial modes for the absorption boundary condition. The self-radiation impedances and mutual impedances for some acoustic modes are calculated for the ducts with rigid and absorption walls. The results show that the acoustical conditions of the duct walls have a significant influence on the radiation impedance. The acoustical interaction between the two open ends of the ducts cannot be neglected, especially for plane waves. To increase the wall admittance will reduce this interference effect. This study creates the possibility for simulating the sound field inside finite ducts in future work.
Results of duct area ratio changes in the NASA Lewis H2-O2 combustion MHD experiment
NASA Technical Reports Server (NTRS)
Smith, J. M.
1979-01-01
MHD power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, generator loading B field strength, and electrode breakdown voltage were investigated. The effect of area ratio, multiple loading of the duct, and duct location within the magnetic field are considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verce, M F; Jayaraman, B; Ford, T D
2007-09-07
This work examined the behavior of vaporous hydrogen peroxide (VHP) in clean, room-scale galvanized steel (GS) and polyvinylchloride-coated steel air ducts, to understand how it might be used to decontaminate larger ventilation systems. VHP injected into the GS duct decreased in concentration along the length of the duct, whereas VHP concentrations in the polyvinylchloride coated duct remained essentially constant, suggesting that VHP decomposed at the GS surface. However, decomposition was reduced at lower temperatures ({approx} 22 C) and higher flow rates ({approx} 80 actual cubic meter per hour). A computational fluid dynamics model incorporating reactive transport was used to estimatemore » surface VHP concentrations where contamination is likely to reside, and also showed how bends encourage VHP decomposition. Use of G. stearothermophilus indicators, in conjunction with model estimates, indicated that a concentration-contact time of {approx} 100 mg/L H{sub 2}O{sub 2}(g){center_dot}min was required to achieve a 6 log reduction of indicator spores in clean GS duct, at 30 C. When VHP is selected for building decontamination, this work suggests the most efficacious strategy may be to decontaminate GS ducting separately from the rest of the building, as opposed to a single decontamination event in which the ventilation system is used to distribute VHP throughout the entire building.« less
Mathematical modeling of flow in the working part of an acousto-convective drying system
NASA Astrophysics Data System (ADS)
Kravchenko, A. S.; Zhilin, A. A.; Fedorova, N. N.
2018-03-01
The objective of this study was to numerically simulate the nonstationary processes occurring in the acoustic-convective dryer (ACD) channel. In the present work, the problem was solved numerically in a three-dimensional formulation taking into account all features of the ACD duct in real geometry. The processes occurring in the ACD duct were simulated using the ANSYS Fluent 18.0 software. The numerical experiments provided an aggregate picture of the working gas flow in the ACD duct with the features near the subsonic nozzle and the cavity. The results of the numerical calculations were compared with experimental data. The best agreement with the experimental data was obtained for the viscosity model neglecting turbulent effects.
Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu
2015-12-01
Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.
Truss-Integrated Thermoformed Ductwork Final Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steven Winter; Dianne Griffiths; Ravi Gorthala
2007-08-30
This report summarizes a multi-year research effort to develop a leak-free duct system that can be readily installed within the thermal envelope. There are numerous efforts underway to improve duct system efficiency. Most of these involve modifications to current technology such as air sealing techniques like mastic and aeroseal, snap together duct connections, and greater levels of insulation. This project sought to make a more significant stride forward by introducing a duct system of a material that can be more readily sealed and can exhibit lower friction losses. The research focused on the use of smooth internal surface, low frictionmore » plastic ducts that could be easily installed with very low air leakage. The initial system concept that was proposed and researched in Phase I focused on the use of thermoformed plastic ducts installed in a recessed roof truss underneath the attic insulation. A bench top thermoformed system was developed and tested during Phase I of the project. In Phase II, a first generation duct system utilizing a resin impregnated fiberglass duct product was designed and specified. The system was installed and tested in an Atlanta area home. Following this installation research and correspondence with code officials was undertaken to alleviate the continued concern over the code acceptance of plastic ducts in above ground applications. A Committee Interpretation response was received from the International Code Council (ICC) stating that plastic ducts were allowed, but must be manufactured from materials complying with Class 0 or Class 1 rating. With assurance of code acceptance, a plastic duct system using rotomolded high density polyethylene ducts that had passed the material test requirements by impregnating the material with a fire retardant during the molding process was installed in the basement of a new ranch-style home in Madison, WI. A series of measurements to evaluate the performance benefits relative to a similar control house with a standard sheet metal installation were made.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences, 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs, and 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less
Compact Buried Ducts in a Hot-Humid Climate House
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, Dave
2016-01-07
"9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less
Ramalingam, Kirithiga; Vuthaluru, Seenu; Srivastava, Anurag; Dinda, Amit Kumar; Dhar, Anita
2017-01-01
Duct ectasia (DE) and periductal mastitis (PDM) are the most common benign breast conditions seen in women. The etiopathogenesis of these entities is still not clear and most of the theories regarding the causation are based on the histological features as seen on light microscopy. The ultramicroscopic features associated with these conditions that may give more insight to the etiopathogenesis are unknown. To study the ultrastructural changes occurring in mammary duct cones in patients with DE and PDM using Transmission Electron Microscopic (TEM). Major ducts removed by radical duct excision from 21 patients with final histopathological diagnosis of DE and PDM were subjected to TEM study with 2 normal duct samples as controls. The TEM features of DE were denudation of the epithelial cells with focal loss of microvilli, widening of the inter-epithelial junctions with focal disruption of the T bars, periductal collagenisation without inflammation, and features suggestive of Epithelial Mesenchymal Transition (EMT). PDM features are intact epithelial lining with proliferative epithelium and periductal collagenisation with inflammation. Based on the TEM findings, we suggest that DE and PDM are two different entities. EMT a novel finding observed in DE in this study.
Ramalingam, Kirithiga; Vuthaluru, Seenu; Srivastava, Anurag; Dinda, Amit Kumar; Dhar, Anita
2017-01-01
Introduction Duct ectasia (DE) and periductal mastitis (PDM) are the most common benign breast conditions seen in women. The etiopathogenesis of these entities is still not clear and most of the theories regarding the causation are based on the histological features as seen on light microscopy. The ultramicroscopic features associated with these conditions that may give more insight to the etiopathogenesis are unknown. Aim To study the ultrastructural changes occurring in mammary duct cones in patients with DE and PDM using Transmission Electron Microscopic (TEM). Method Major ducts removed by radical duct excision from 21 patients with final histopathological diagnosis of DE and PDM were subjected to TEM study with 2 normal duct samples as controls. Results The TEM features of DE were denudation of the epithelial cells with focal loss of microvilli, widening of the inter-epithelial junctions with focal disruption of the T bars, periductal collagenisation without inflammation, and features suggestive of Epithelial Mesenchymal Transition (EMT). PDM features are intact epithelial lining with proliferative epithelium and periductal collagenisation with inflammation. Conclusions Based on the TEM findings, we suggest that DE and PDM are two different entities. EMT a novel finding observed in DE in this study. PMID:28273122
A quantitative analysis of electrolyte exchange in the salivary duct
Catalán, Marcelo A.; Melvin, James E.; Yule, David I.; Crampin, Edmund J.; Sneyd, James
2012-01-01
A healthy salivary gland secretes saliva in two stages. First, acinar cells generate primary saliva, a plasma-like, isotonic fluid high in Na+ and Cl−. In the second stage, the ducts exchange Na+ and Cl− for K+ and HCO3−, producing a hypotonic final saliva with no apparent loss in volume. We have developed a tool that aims to understand how the ducts achieve this electrolyte exchange while maintaining the same volume. This tool is part of a larger multiscale model of the salivary gland and can be used at the duct or gland level to investigate the effects of genetic and chemical alterations. In this study, we construct a radially symmetric mathematical model of the mouse salivary gland duct, representing the lumen, the cell, and the interstitium. For a given flow and primary saliva composition, we predict the potential differences and the luminal and cytosolic concentrations along a duct. Our model accounts well for experimental data obtained in wild-type animals as well as knockouts and chemical inhibitors. Additionally, the luminal membrane potential of the duct cells is predicted to be very depolarized compared with acinar cells. We investigate the effects of an electrogenic vs. electroneutral anion exchanger in the luminal membrane on concentration and the potential difference across the luminal membrane as well as how impairing the cystic fibrosis transmembrane conductance regulator channel affects other ion transporting mechanisms. Our model suggests the electrogenicity of the anion exchanger has little effect in the submandibular duct. PMID:22899825
Biliary hemorrhage after removal of an expandable metallic stent during liver transplantation.
Narumi, Shunji; Hakamda, Kenichi; Toyoki, Yoshikazu; Ishido, Keinosuke; Nara, Masaki; Yoshihara, Syuichi; Sasaki, Mutsuo
2008-11-01
The self-expandable metallic stent (SEMS) has become a common device for palliative treatment of malignant biliary obstructions or benign strictures. Despite the ease of placement of SEMSs, their removal has been reported to be very difficult. Here, we report a case with primary sclerosing cholangitis who developed massive hemorrhage after intraoperative removal of a SEMS. Possible living donor liver transplantation (LT) was considered for a 49-year-old female with primary sclerosing cholangitis. However, her general condition did not meet the criteria for LT; therefore, she was referred back to her primary physician. Two years later, she developed jaundice, and her primary physician placed multiple SEMSs, 1 of which was placed across the papilla of Vater. She was evaluated rapidly, and underwent living donor LT. During the operation, the common bile duct was examined and an incision was made. A stent was found firmly embedded in the bile duct. Each wire of the SEMS was pinched and then successfully pulled out 1 by 1. Finally, all parts of the SEMS were removed. Before creating the Roux-en-Y limb, hemorrhage from the remnant bile duct was confirmed by examination of the duodenum and bile duct stump. The bile duct was sewn internally with monofilament stitches and compressed for 10 minutes. Finally, hemostasis was brought about and transplantation was completed successfully. Despite some reports regarding successful endoscopic removal of SEMSs, its removal in patients with portal hypertension coagulopathy is risky. SEMSs should not be placed in patients who are candidates for LT.
Kitamura, Katsuya; Yamamiya, Akira; Ishii, Yu; Sato, Yoshiki; Iwata, Tomoyuki; Nomoto, Tomohiro; Ikegami, Akitoshi; Yoshida, Hitoshi
2015-01-01
AIM: To compare the clinical outcomes between 0.025-inch and 0.035-inch guide wires (GWs) when used in wire-guided cannulation (WGC). METHODS: A single center, randomized study was conducted between April 2011 and March 2013. This study was approved by the Medical Ethics Committee at our hospital. Informed, written consent was obtained from each patient prior to study enrollment. Three hundred and twenty-two patients with a naïve papilla of Vater who underwent endoscopic retrograde cholangiopancreatography (ERCP) for the purpose of selective bile duct cannulation with WGC were enrolled in this study. Fifty-three patients were excluded based on the exclusion criteria, and 269 patients were randomly allocated to two groups by a computer and analyzed: the 0.025-inch GW group (n = 109) and the 0.035-inch GW group (n = 160). The primary endpoint was the success rate of selective bile duct cannulation with WGC. Secondary endpoints were the success rates of the pancreatic GW technique and precutting, selective bile duct cannulation time, ERCP procedure time, the rate of pancreatic duct stent placement, the final success rate of selective bile duct cannulation, and the incidence of post-ERCP pancreatitis (PEP). RESULTS: The primary success rates of selective bile duct cannulation with WGC were 80.7% (88/109) and 86.3% (138/160) for the 0.025-inch and the 0.035-inch groups, respectively (P = 0.226). There were no statistically significant differences in the success rates of selective bile duct cannulation using the pancreatic duct GW technique (46.7% vs 52.4% for the 0.025-inch and 0.035-inch groups, respectively; P = 0.884) or in the success rates of selective bile duct cannulation using precutting (66.7% vs 63.6% for the 0.025-inch and 0.035-inch groups, respectively; P = 0.893). The final success rates for selective bile duct cannulation using these procedures were 92.7% (101/109) and 97.5% (156/160) for the 0.025-inch and 0.035-inch groups, respectively (P = 0.113). There were no significant differences in selective bile duct cannulation time (median ± interquartile range: 3.7 ± 13.9 min vs 4.0 ± 11.2 min for the 0.025-inch and 0.035-inch groups, respectively; P = 0.851), ERCP procedure time (median ± interquartile range: 32 ± 29 min vs 30 ± 25 min for the 0.025-inch and 0.035-inch groups, respectively; P = 0.184) or in the rate of pancreatic duct stent placement (14.7% vs 15.6% for the 0.025-inch and 0.035-inch groups, respectively; P = 0.832). The incidence of PEP was 2.8% (3/109) and 2.5% (4/160) for the 0.025-inch and 0.035-inch groups, respectively (P = 0.793). CONCLUSION: The thickness of the GW for WGC does not appear to affect either the success rate of selective bile duct cannulation or the incidence of PEP. PMID:26290646
Aerodynamic analysis and simulation of a twin-tail tilt-duct unmanned aerial vehicle
NASA Astrophysics Data System (ADS)
Abdollahi, Cyrus
The tilt-duct vertical takeoff and landing (VTOL) concept has been around since the early 1960s; however, to date the design has never passed the research phase and development phase. Nearly 50 years later, American Dynamics Flight Systems (ADFS) is developing the AD-150, a 2,250lb weight class unmanned aerial vehicle (UAV) configured with rotating ducts on each wingtip. Unlike its predecessor, the Doak VZ-4, the AD-150 features a V tail and wing sweep -- both of which affect the aerodynamic behavior of the aircraft. Because no aircraft of this type has been built and tested, vital aerodynamic research was conducted on the bare airframe behavior (without wingtip ducts). Two weeks of static and dynamic testing were performed on a 3/10th scale model at the University of Maryland's 7' x 10' low speed wind tunnel to facilitate the construction of a nonlinear flight simulator. A total of 70 dynamic tests were performed to obtain damping parameter estimates using the ordinary least squares methodology. Validation, based on agreement between static and dynamic estimates of the pitch and yaw stiffness terms, showed an average percent error of 14.0% and 39.6%, respectively. These inconsistencies were attributed to: large dynamic displacements not encountered during static testing, regressor collinearity, and, while not conclusively proven, differences in static and dynamic boundary layer development. Overall, the damping estimates were consistent and repeatable, with low scatter over a 95% confidence interval. Finally, a basic open loop simulation was executed to demonstrate the instability of the aircraft. As a result, it is recommended that future work be performed to determine trim points and linear models for controls development.
Broadband Fan Noise Generated by Small Scale Turbulence
NASA Technical Reports Server (NTRS)
Glegg, Stewart A. L.
1998-01-01
This report describes the development of prediction methods for broadband fan noise from aircraft engines. First, experimental evidence of the most important source mechanisms is reviewed. It is found that there are a number of competing source mechanism involved and that there is no single dominant source to which noise control procedures can be applied. Theoretical models are then developed for: (1) ducted rotors and stator vanes interacting with duct wall boundary layers, (2) ducted rotor self noise, and (3) stator vanes operating in the wakes of rotors. All the turbulence parameters required for these models are based on measured quantities. Finally the theoretical models are used to predict measured fan noise levels with some success.
BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.
DOE Office of Scientific and Technical Information (OSTI.GOV)
ANDREWS,J.
This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.
Ducted fuel injection: A new approach for lowering soot emissions from direct-injection engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, Charles J.; Nilsen, Christopher W.; Ruth, Daniel J.
Designers of direct-injection compression-ignition engines use a variety of strategies to improve the fuel/charge-gas mixture within the combustion chamber for increased efficiency and reduced pollutant emissions. Strategies include the use of high fuel-injection pressures, multiple injections, small injector orifices, flow swirl, long-ignition-delay conditions, and oxygenated fuels. This is the first journal publication paper on a new mixing-enhancement strategy for emissions reduction: ducted fuel injection. The concept involves injecting fuel along the axis of a small cylindrical duct within the combustion chamber, to enhance the mixture in the autoignition zone relative to a conventional free-spray configuration (i.e., a fuel spray thatmore » is not surrounded by a duct). Finally, the results described herein, from initial proof-of-concept experiments conducted in a constant-volume combustion vessel, show dramatically lower soot incandescence from ducted fuel injection than from free sprays over a range of charge-gas conditions that are representative of those in modern direct-injection compression-ignition engines.« less
A Flight Study of the Conversion Maneuver of a Tilt-Duct VTOL Aircraft
NASA Technical Reports Server (NTRS)
Tapscott, Robert J.; Kelley, Henry L.
1960-01-01
Flight records are presented from an early flight test of a wing-tip mounted tilting-ducted-fan, vertical-take-off and landing (VTOL) aircraft configuration. Time histories of the aircraft motions, control positions, and duct pitching-moment variation are presented to illustrate the characteristics of the aircraft in hovering, in conversion from hovering to forward flight, and in conversion from forward flight to hovering. The results indicate that during essentially continuous slow level- flight conversions, this aircraft experiences excessive longitudinal trim changes. Studies have shown that the large trim changes are caused primarily by the variation of aerodynamic moments acting on the duct units. Action of the duct-induced downwash on the horizontal stabilizer during the conversion also contributes to the longitudinal trim variations. Time histories of hovering and slow vertical descent in the final stages of landing in calm air show angular motions of the aircraft as great as +/- 10 deg. about all axes. Stick and pedal displacements required to control the aircraft during the landing maneuver were on the order of 50 to 60 percent of the total travel available.
Ducted fuel injection: A new approach for lowering soot emissions from direct-injection engines
Mueller, Charles J.; Nilsen, Christopher W.; Ruth, Daniel J.; ...
2017-07-18
Designers of direct-injection compression-ignition engines use a variety of strategies to improve the fuel/charge-gas mixture within the combustion chamber for increased efficiency and reduced pollutant emissions. Strategies include the use of high fuel-injection pressures, multiple injections, small injector orifices, flow swirl, long-ignition-delay conditions, and oxygenated fuels. This is the first journal publication paper on a new mixing-enhancement strategy for emissions reduction: ducted fuel injection. The concept involves injecting fuel along the axis of a small cylindrical duct within the combustion chamber, to enhance the mixture in the autoignition zone relative to a conventional free-spray configuration (i.e., a fuel spray thatmore » is not surrounded by a duct). Finally, the results described herein, from initial proof-of-concept experiments conducted in a constant-volume combustion vessel, show dramatically lower soot incandescence from ducted fuel injection than from free sprays over a range of charge-gas conditions that are representative of those in modern direct-injection compression-ignition engines.« less
Sripa, Banchob; Thinkhamrop, Bandit; Mairiang, Eimorn; Laha, Thewarach; Kaewkes, Sasithorn; Sithithaworn, Paiboon; Periago, Maria Victoria; Bhudhisawasdi, Vajarabhongsa; Yonglitthipagon, Ponlapat; Mulvenna, Jason; Brindley, Paul J.; Loukas, Alex; Bethony, Jeffrey M.
2012-01-01
Opisthorchis viverrini is considered among the most important of the food-borne trematodes due to its strong association with advanced periductal fibrosis and bile duct cancer (cholangiocarcinoma). We investigated the relationship between plasma levels of Interleukin (IL)-6 and the risk of developing advanced fibrosis and bile duct cancer from chronic Opisthorchis infection. We show that IL-6 circulates in plasma at concentrations 58 times higher in individuals with advanced fibrosis than age, sex, and nearest-neighbor matched controls and 221 times higher in individuals with bile duct cancer than controls. We also observed a dose-response relationship between increasing levels of plasma IL-6 and increasing risk of advanced fibrosis and bile duct cancer; for example, in age and sex adjusted analyses, individuals with the highest quartiles of plasma IL-6 had a 19 times greater risk of developing advanced periductal fibrosis and a 150 times greater risk of developing of bile duct cancer than individuals with no detectable level of plasma IL-6. Finally, we show that a single plasma IL-6 measurement has excellent positive predictive value for the detection of both advanced bile duct fibrosis and bile duct cancer in regions with high O. viverrini transmission. These data support our hypothesis that common mechanisms drive bile duct fibrosis and bile duct tumorogenesis from chronic O. viverrini infection. Our study also adds a unique aspect to the literature on circulating levels of IL-6 as an immune marker of hepatobiliary pathology by showing that high levels of circulating IL-6 in plasma are not related to infection with O. viverrini, but to the development of the advanced and often lethal pathologies resulting from chronic O. viverrini infection. PMID:22629477
NASA Astrophysics Data System (ADS)
Sun, Zheng; Ning, Hui; Song, Shihui; Yan, Dongmei
2016-10-01
Nocturnal radiative cooling is a main driver for atmospheric duct formation. Within this atmospheric process, the impacts of intermittent turbulence on ducting have seldom been studied. In this paper, we reported two confusing ducting events observed in the early morning in August 2014 over Bosten Lake, China, when a stable boundary layer (SBL) still survived, by using tethered high-resolution GPS radiosondes. Elevated ducts with strong humidity inversions were observed during the balloon ascents but were absent during observations made upon the balloon descents several minutes later. This phenomenon was initially hypothesized to be attributable to turbulence motions in the SBL, and the connection between the turbulence event and the radar duct was examined by the statistical Thorpe method. Turbulence patches were detected from the ascent profiles but not from the descent profiles. The possible reasons for the duct formation and elimination were discussed in detail. The turbulent transport of moisture in the SBL and the advection due to airflows coming from the lake are the most probable reasons for duct formation. In one case, the downward transport of moisture by turbulence mixing within a Kelvin-Helmholtz billow at the top of the low-level jet resulted in duct elimination. In another case, the passage of density currents originating from the lake may have caused the elimination of the duct. Few studies have attempted to associate intermittent turbulence with radar ducts; thus, this work represents a pioneering study into the connection between turbulent events and atmospheric ducts in a SBL.
CFD analysis of gas explosions vented through relief pipes.
Ferrara, G; Di Benedetto, A; Salzano, E; Russo, G
2006-09-21
Vent devices for gas and dust explosions are often ducted to safe locations by means of relief pipes. However, the presence of the duct increases the severity of explosion if compared to simply vented vessels (i.e. compared to cases where no duct is present). Besides, the identification of the key phenomena controlling the violence of explosion has not yet been gained. Multidimensional models coupling, mass, momentum and energy conservation equations can be valuable tools for the analysis of such complex explosion phenomena. In this work, gas explosions vented through ducts have been modelled by a two-dimensional (2D) axi-symmetric computational fluid dynamic (CFD) model based on the unsteady Reynolds Averaged Navier Stokes (RANS) approach in which the laminar, flamelet and distributed combustion models have been implemented. Numerical test have been carried out by varying ignition position, duct diameter and length. Results have evidenced that the severity of ducted explosions is mainly driven by the vigorous secondary explosion occurring in the duct (burn-up) rather than by the duct flow resistance or acoustic enhancement. Moreover, it has been found out that the burn-up affects explosion severity due to the reduction of venting rate rather than to the burning rate enhancement through turbulization.
Evaporative cooler including one or more rotating cooler louvers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerlach, David W
An evaporative cooler may include an evaporative cooler housing with a duct extending therethrough, a plurality of cooler louvers with respective porous evaporative cooler pads, and a working fluid source conduit. The cooler louvers are arranged within the duct and rotatably connected to the cooler housing along respective louver axes. The source conduit provides an evaporative cooler working fluid to the cooler pads during at least one mode of operation.
Marchisio, Daniele L; Galan, Miquel; Barresi, Antonello A
2018-05-05
This manuscript shows how computational models, mainly based on Computational Fluid Dynamics (CFD), can be used to simulate different parts of an industrial freeze-drying equipment and to properly design them; in particular in this part the duct connecting the chamber with the condenser, with its valves, is considered, while the chamber design and its effect on drying kinetics have been investigated in Part 1. Such an approach allows a much deeper process understanding and assessment of the critical aspects of lyophilisation. This methodology will be demonstrated on freeze-drying equipment of different sizes, investigating influence of valve type (butterfly and mushroom) and shape on duct conductance and critical flow conditions. The role of the inlet and boundary conditions considered has been assessed, also by modelling the whole apparatus including chamber and condenser, and the influence of the duct diameter has been discussed; the results show a little dependence of the relationship between critical mass flux and chamber pressure on the duct size. Results concerning the fluid dynamics of a simple disk valve, a profiled butterfly valve and a mushroom valve installed in a medium size horizontal condenser are presented. Also in these cases the maximum allowable flow when sonic flow conditions are reached can be described by a correlation similar to that found valid for empty ducts; for the mushroom valve the parameters are dependent on the valve opening length. The possibility to use the equivalent length concept, and to extend the validity of the results obtained for empty ducts will be also discussed. Finally the presence of the inert gas modifies the conductance of the duct, reducing the maximum flow rate of water that can be removed through it before the flow is choked; this also requires a proper over-sizing of the duct (or duct-butterfly valve system). Copyright © 2018. Published by Elsevier B.V.
Kunovsky, Lumir; Kala, Zdenek; Svaton, Roman; Moravcik, Petr; Mazanec, Jan; Husty, Jakub; Prochazka, Vladimir
2018-01-01
Mucinous cystic neoplasm of the liver (MCN-L) and intraductal papillary mucinous neoplasm of the bile duct (IPMN-B) are diagnoses that were classified by the World Health Organization in 2010 as mucin-producing bile duct tumors of the hepatobiliary system. The preoperative differential diagnosis between these two entities is difficult; the presence of a communication with the bile duct is usually considered as a typical sign of IPMN-B. However, the presence of an ovarian-like stroma (OLS) has been established to define the diagnosis of MCN-L. We present the case of a 33-year-old woman with a rapid progression of a cystic tumor of the liver. In 2 years, the lesion increased from 27 to 64 mm and a dilation of the left hepatic duct appeared. Percutaneous transhepatic drainage with a biopsy was performed. No malignant cells were found on biopsy. Because of the rapid progression of the cystic tumor and unclear malignant potential, left hemihepatectomy was performed. Even though tumor masses were present in the biliary duct, on the basis of the presence of OLS, histology finally confirmed MCN-L with intermediate-grade intraepithelial dysplasia to high-grade intraepithelial dysplasia. The patient is currently under oncologic follow-up with no signs of recurrence of the disease. We present a rare case where MCN-L caused a dilation of the left hepatic duct, a sign that is usually a characteristic of IPMN-B.
Fan noise prediction assessment
NASA Technical Reports Server (NTRS)
Bent, Paul H.
1995-01-01
This report is an evaluation of two techniques for predicting the fan noise radiation from engine nacelles. The first is a relatively computational intensive finite element technique. The code is named ARC, an abbreviation of Acoustic Radiation Code, and was developed by Eversman. This is actually a suite of software that first generates a grid around the nacelle, then solves for the potential flowfield, and finally solves the acoustic radiation problem. The second approach is an analytical technique requiring minimal computational effort. This is termed the cutoff ratio technique and was developed by Rice. Details of the duct geometry, such as the hub-to-tip ratio and Mach number of the flow in the duct, and modal content of the duct noise are required for proper prediction.
The stratospheric arrival pair in infrasound propagation.
Waxler, Roger; Evers, Läslo G; Assink, Jelle; Blom, Phillip
2015-04-01
The ideal case of a deep and well-formed stratospheric duct for long range infrasound propagation in the absence of tropospheric ducting is considered. A canonical form, that of a pair of arrivals, for ground returns of impulsive signals in a stratospheric duct is determined. The canonical form is derived from the geometrical acoustics approximation, and is validated and extended through full wave modeling. The full caustic structure of the field of ray paths is found and used to determine phase relations between the contributions to the wavetrain from different propagation paths. Finally, comparison with data collected from the 2005 fuel gas depot explosion in Buncefield, England is made. The correspondence between the theoretical results and the observations is shown to be quite good.
Duct wall impedance control as an advanced concept for acoustic impression
NASA Technical Reports Server (NTRS)
Dean, P. D.; Tester, B. J.
1975-01-01
Models and tests on an acoustic duct liner system which has the property of controlled-variable acoustic impedance are described. This is achieved by a novel concept which uses the effect of steady air flow through a multi-layer, locally reacting, resonant-cavity absorber. The scope of this work was limited to a 'proof of concept.' The test of the concept was implemented by means of a small-scale, square-section flow duct facility designed specifically for acoustic measurements, with one side of the duct acoustically lined. The test liners were designed with the aid of previously established duct acoustic theory and a semi-empirical impedance model of the liner system. Over the limited range tested, the liner behaved primarily as predicted, exhibiting significant changes in resistance and reactance, thus providing the necessary concept validation.
Management of intraductal papillary mucinous neoplasms.
Crippa, Stefano; Fernández-del Castillo, Carlos
2008-04-01
Intraductal papillary mucinous neoplasms (IPMNs) of the pancreas are being diagnosed with increasing frequency, probably due to the widespread use of cross-sectional imaging. The natural history of these tumors is still largely unknown. Several studies have shown topographical as well as biological differences between main duct and branch duct IPMNs. In the past few years, diagnostic work-up and, in particular, management of these tumors have evolved significantly. Data support the need for resection of main duct IPMNs and the possibility of nonoperative management in selected cases of branch duct tumors. In this systematic review, we analyze the most recent publications related to IPMNs, with particular emphasis on problems related to managing this challenging disease.
Karsenti, D
2013-06-01
Endoscopic treatment has become, according to the latest recommendations, the standard treatment for common bile duct stones (CBDS), although in certain situations, surgical clearance of the common duct at the time of laparoscopic cholecystectomy is still considered a possible alternative. The purpose of this article is not to compare endoscopic with surgical treatment of CBDS, but to describe the various techniques of endoscopic treatment, detailing their preferential indications and the various treatment options that must sometimes be considered when faced with "difficult calculi" of the CBD. The different techniques of lithotripsy and the role of biliary drainage with plastic or metallic stents will be detailed as well as papillary balloon dilatation and particularly the technique of sphincterotomy with macrodilatation of the sphincter of Oddi (SMSO), a recently described approach that has changed the strategy for endoscopic management of CBDS. Finally, the overall strategy for endoscopic management of CBDS, with description of different techniques, will be exposed. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Theoretical models for duct acoustic propagation and radiation
NASA Technical Reports Server (NTRS)
Eversman, Walter
1991-01-01
The development of computational methods in acoustics has led to the introduction of analysis and design procedures which model the turbofan inlet as a coupled system, simultaneously modeling propagation and radiation in the presence of realistic internal and external flows. Such models are generally large, require substantial computer speed and capacity, and can be expected to be used in the final design stages, with the simpler models being used in the early design iterations. Emphasis is given to practical modeling methods that have been applied to the acoustical design problem in turbofan engines. The mathematical model is established and the simplest case of propagation in a duct with hard walls is solved to introduce concepts and terminologies. An extensive overview is given of methods for the calculation of attenuation in uniform ducts with uniform flow and with shear flow. Subsequent sections deal with numerical techniques which provide an integrated representation of duct propagation and near- and far-field radiation for realistic geometries and flight conditions.
Eckhard, A; Löwenheim, H
2014-06-01
Sound transduction in the cochlea critically depends on the circulation of potassium ions (K(+)) along so-called "K(+) recycling routes" between the endolymph and perilymph. These K(+) currents generate high ionic and osmotic gradients, which potentially impair the excitability of sensory hair cells and threaten cell survival in the entire cochlear duct. Molecular water channels-aquaporins (AQP)-are expressed in all cochlear supporting cells along the K(+) recycling routes; however, their significance for osmotic equilibration in cochlear duct cells is unknown. The diffusive and osmotic water permeabilies of Reissner's membrane, the organ of Corti and the entire cochlear duct epithelium were determined. Expression of the potassium channel Kir4.1 and the water channel AQP4 in the cochlear duct was investigated by immunohistochemistry. The calculated water permeability values indicate the extent of AQP-facilitated water flux across the cochlear duct epithelium. Immunohistochemically, Kir4.1 and AQP4 were found to colocalize in distinct membrane domains of supporting cells along the K(+)-recycling routes. These observations suggest the presence of a rapid AQP-mediated water exchange between the endolymph, the cells of the cochlear duct and the perilymph. The subcellular colocalization of Kir4.1 and AQP4 in epithelial supporting cells indicates functional coupling of potassium and water flow in the cochlea. Finally, this offers an explanation for the hearing impairment observed in individuals with mutations in the AQP4 gene.
IFCPT S-Duct Grid-Adapted FUN3D Computations for the Third Propulsion Aerodynamics Works
NASA Technical Reports Server (NTRS)
Davis, Zach S.; Park, M. A.
2017-01-01
Contributions of the unstructured Reynolds-averaged Navier-Stokes code, FUN3D, to the 3rd AIAA Propulsion Aerodynamics Workshop are described for the diffusing IFCPT S-Duct. Using workshop-supplied grids, results for the baseline S-Duct, baseline S-Duct with Aerodynamic Interface Plane (AIP) rake hardware, and baseline S-Duct with flow control devices are compared with experimental data and results computed with output-based, off-body grid adaptation in FUN3D. Due to the absence of influential geometry components, total pressure recovery is overpredicted on the baseline S-Duct and S-Duct with flow control vanes when compared to experimental values. An estimate for the exact value of total pressure recovery is derived for these cases given an infinitely refined mesh. When results from output-based mesh adaptation are compared with those computed on workshop-supplied grids, a considerable improvement in predicting total pressure recovery is observed. By including more representative geometry, output-based mesh adaptation compares very favorably with experimental data in terms of predicting the total pressure recovery cost-function; whereas, results computed using the workshop-supplied grids are underpredicted.
The effects of air leaks on solar air heating systems
NASA Technical Reports Server (NTRS)
Elkin, R.; Cash, M.
1979-01-01
This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.
Flow in curved ducts of varying cross-section
NASA Astrophysics Data System (ADS)
Sotiropoulos, F.; Patel, V. C.
1992-07-01
Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.
Bonkovsky, Herbert L.; Kleiner, David E.; Gu, Jiezhun; Odin, Joseph A.; Russo, Mark W.; Navarro, Victor M.; Fontana, Robert J.; Ghabril, Marwan S.; Barnhart, Huiman; Hoofnagle, Jay H.
2016-01-01
Bile duct loss during the course of drug induced liver injury is uncommon but can be an indication of vanishing bile duct syndrome. In this work we assess the frequency, causes, clinical features and outcomes of cases of drug induced liver injury with histologically proven bile duct loss. All cases of drug induced liver injury enrolled into a prospective database over a ten year period that had undergone liver biopsies (n=363) were scored for the presence of bile duct loss and assessed for clinical and laboratory features, causes and outcomes. 26 of the 363 patients (7%) with drug, herbal or dietary supplement associated liver injury had bile duct loss on liver biopsy which was moderate to severe (<50% of portal areas with bile ducts) in 14 and mild (50–75%) in 12. The presenting clinical features of the 26 cases varied, but the most common clinical pattern was a severe cholestatic hepatitis. The implicated agents included amoxicillin/clavulanate (n=3), temozolomide (n=3), various herbal products (n=3), azithromycin (n=2) and 15 other medications or dietary supplements. Compared to those without, those with bile duct loss were more likely to develop chronic liver injury (94% vs 47%), which was usually cholestatic and sometimes severe. Five patients died and two others underwent liver transplantation for progressive cholestasis despite treatment with corticosteroids and ursodiol. The most predictive factor of poor outcome was the degree of bile duct loss on liver biopsy. Conclusions Bile duct loss during acute cholestatic hepatitis is an ominous early indicator of possible vanishing bile duct syndrome, for which at present there are no known means of prevention or therapy. PMID:27981596
NASA Astrophysics Data System (ADS)
Rohlfing, J.; Gardonio, P.
2014-02-01
This paper presents theoretical and experimental work on concurrent active noise and vibration control for a ventilation duct. The active noise control system is used to reduce the air-borne noise radiated via the duct outlet whereas the active vibration control system is used to both reduce the structure-borne noise radiated by the duct wall and to minimise the structural feed-through effect that reduces the effectiveness of the active noise control system. An elemental model based on structural mobility functions and acoustic impedance functions has been developed to investigate the principal effects and limitations of feed-forward active noise control and decentralised velocity feedback vibration control. The principal simulation results have been contrasted and validated with measurements taken on a laboratory duct set-up, equipped with an active noise control system and a decentralised vibration control system. Both simulations and experimental results show that the air-borne noise radiated from the duct outlet can be significantly attenuated using the feed-forward active noise control. In the presence of structure-borne noise the performance of the active noise control system is impaired by a structure-borne feed-through effect. Also the sound radiation from the duct wall is increased. In this case, if the active noise control is combined with a concurrent active vibration control system, the sound radiation by the duct outlet is further reduced and the sound radiation from the duct wall at low frequencies reduces noticeably.
2015-09-01
associated duct banks and electrical components, and an airfield lighting vault are required. 1.3 SCOPE OF THE EA This EA evaluates the potential impacts on...Taxiway Whiskey. The east side work includes constructing an access road to serve the vault and installing a new 80-way duct bank connecting the east...Maryland September 2015 2-3 the East Runway and Taxiway Echo. On the west side of the airfield the duct bank servicing the airfield would be relocated
Compressive MIMO Beamforming of Data Collected in a Refractive Environment
NASA Astrophysics Data System (ADS)
Wagner, Mark; Nannuru, Santosh; Gerstoft, Peter
2017-12-01
The phenomenon of ducting is caused by abnormal atmospheric refractivity patterns and is known to allow electromagnetic waves to propagate over the horizon with unusually low propagation loss. It is unknown what effect ducting has on multiple input multiple output (MIMO) channels, particularly its effect on multipath propagation in MIMO channels. A high-accuracy angle-of-arrival and angle-of-departure estimation technique for MIMO communications, which we will refer to as compressive MIMO beamforming, was tested on simulated data then applied to experimental data taken from an over the horizon MIMO test bed located in a known ducting hot spot in Southern California. The multipath channel was estimated from the receiver data recorded over a period of 18 days, and an analysis was performed on the recorded data. The goal is to observe the evolution of the MIMO multipath channel as atmospheric ducts form and dissipate to gain some understanding of the behavior of channels in a refractive environment. This work is motivated by the idea that some multipath characteristics of MIMO channels within atmospheric ducts could yield important information about the duct.
1998-10-10
Isolation of human mammary epithelial cells (HMEC) from breast cancer susceptible tissue; A: Duct element recovered from breast tissue digest. B: Outgrowth of cells from duct element in upper right corner cultured in a standard dish; most cells spontaneousely die during early cell divisions, but a few will establish long-term growth. C: Isolate of long-term frowth HMEC from outgrowth of duct element; cells shown soon after isolation and in early full-cell contact growth in culture in a dish. D: same long-term growth HMEC, but after 3 weeks in late full-cell contact growth in a continuous culture in a dish. Note attempts to reform duct elements but this in two demensions in a dish rather than in three dimensions in tissue. NASA's Marshall Space Flight Center (MSFC) is sponsoring research with Bioreactors, rotating wall vessels designed to grow tissue samples in space, to understand how breast cancer works. This ground-based work studies the growth and assembly of human mammary epithelial cell (HMEC) from breast cancer susceptible tissue. Radiation can make the cells cancerous, thus allowing better comparisons of healthy vs. tunorous tissue. Credit: Dr. Robert Richmond, NASA/Marshall Space Flight Center (MSFC).
Holopainen, R; Tuomainen, M; Asikainen, V; Pasanen, P; Säteri, J; Seppänen, O
2002-09-01
The aim of this study was to evaluate the amount of dust in supply air ducts in recently installed ventilation systems. The samples for the determination of dust accumulation were collected from supply air ducts in 18 new buildings that have been constructed according to two different cleanliness control levels classified as category P1 (low oil residues and protected against contaminations) and category P2, as defined in the Classification of Indoor Climate, Construction and Building Materials. In the ducts installed according to the requirements of cleanliness category P1 the mean amount of accumulated dust was 0.9 g/m2 (0.4-2.9 g/m2), and in the ducts installed according to the cleanliness category P2 it was 2.3 g/m2 (1.2-4.9 g/m2). A significant difference was found in the mean amounts of dust between ducts of categories P1 and P2 (P < 0.008). The cleanliness control procedure in category P1 proved to be a useful and effective tool for preventing dust accumulation in new air ducts during the construction process. Additionally, the ducts without residual oil had lower amounts of accumulated dust indicating that the demand for oil free components in the cleanliness classification is reasonable.
Espinoza, Gabriela M; Lueder, Gregg T
2007-04-01
To evaluate the correlation between persistent symptoms while stents are in place and final outcome in children with nasolacrimal duct obstruction (NLDO). A retrospective observational case series, with medical record review that included indications for surgery, surgical procedure, presence of symptoms while stents were in place, and final outcome after stent removal. Twenty-eight children with NLDO had nasolacrimal duct stents placed in 42 eyes. Twenty-one of the 42 eyes (50%) had minimal or no signs or symptoms of NLDO while stents were in place, and 18 of 21 (86%) were symptom-free after stent removal. Twenty-one of the 42 eyes (50%) remained symptomatic while stents were in place. Eleven of these 21 eyes (52%) had good outcomes after stent removal. Ten (48%) of these patients had persistent symptoms after stent removal requiring further treatment. The prognosis for a good outcome is excellent if symptoms of NLDO resolve while stents are in place. The prognosis is poorer if symptoms of NLDO persist, but more than half of such patients still have good outcomes. Careful counseling of parents regarding these outcomes should be performed before considering additional interventions.
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... The final waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge...) Heel angle. The maximum angle of heel must not exceed 30 degrees. (c) Range of stability. Through an... lines may not be considered for reducing the angle of heel. Spaces joined by ducts of large cross...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... The final waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge...) Heel angle. The maximum angle of heel must not exceed 30 degrees. (c) Range of stability. Through an... lines may not be considered for reducing the angle of heel. Spaces joined by ducts of large cross...
Bonkovsky, Herbert L; Kleiner, David E; Gu, Jiezhun; Odin, Joseph A; Russo, Mark W; Navarro, Victor M; Fontana, Robert J; Ghabril, Marwan S; Barnhart, Huiman; Hoofnagle, Jay H
2017-04-01
Bile duct loss during the course of drug-induced liver injury is uncommon, but can be an indication of vanishing bile duct syndrome (VBDS). In this work, we assess the frequency, causes, clinical features, and outcomes of cases of drug-induced liver injury with histologically proven bile duct loss. All cases of drug-induced liver injury enrolled into a prospective database over a 10-year period that had undergone liver biopsies (n = 363) were scored for the presence of bile duct loss and assessed for clinical and laboratory features, causes, and outcomes. Twenty-six of the 363 patients (7%) with drug-, herbal-, or dietary-supplement-associated liver injury had bile duct loss on liver biopsy, which was moderate to severe (<50% of portal areas with bile ducts) in 14 and mild (50%-75%) in 12. The presenting clinical features of the 26 cases varied, but the most common clinical pattern was a severe cholestatic hepatitis. The implicated agents included amoxicillin/clavulanate (n = 3), temozolomide (n = 3), various herbal products (n = 3), azithromycin (n = 2), and 15 other medications or dietary supplements. Compared to those without, those with bile duct loss were more likely to develop chronic liver injury (94% vs. 47%), which was usually cholestatic and sometimes severe. Five patients died and 2 others underwent liver transplantation for progressive cholestasis despite treatment with corticosteroids and ursodiol. The most predictive factor of poor outcome was the degree of bile duct loss on liver biopsy. Bile duct loss during acute cholestatic hepatitis is an ominous early indicator of possible VBDS, for which at present there are no known means of prevention or therapy. (Hepatology 2017;65:1267-1277). © 2016 by the American Association for the Study of Liver Diseases.
Patent ductus arteriosus: patho-physiology, hemodynamic effects and clinical complications.
Capozzi, Giovanbattista; Santoro, Giuseppe
2011-10-01
During fetal life, patent arterial duct diverts placental oxygenated blood from the pulmonary artery into the aorta by-passing lungs. After birth, decrease of prostacyclins and prostaglandins concentration usually causes arterial duct closure. This process may be delayed, or may even completely fail in preterm infants with arterial duct still remaining patent. If that happens, blood flow by-pass of the systemic circulation through the arterial duct results in pulmonary overflow and systemic hypoperfusion. When pulmonary flow is 50% higher than systemic flow, a hemodynamic "paradox" results, with an increase of left ventricular output without a subsequent increase of systemic output. Cardiac overload support neuro-humoral effects (activation of sympathetic nervous system and renin-angiotensin system) that finally promote heart failure. Moreover, increased pulmonary blood flow can cause vascular congestion and pulmonary edema. However, the most dangerous effect is cerebral under-perfusion due to diastolic reverse-flow and resulting in cerebral hypoxia. At last, blood flow decreases through the abdominal aorta, reducing perfusion of liver, gut and kidneys and may cause hepatic failure, renal insufficiency and necrotizing enterocolitis. Conclusions Large patent arterial duct may cause life-threatening multi-organ effects. In pre-term infant early diagnosis and timely effective treatment are cornerstones in the prevention of cerebral damage and long-term multi-organ failure.
NASA Astrophysics Data System (ADS)
Manousaki, D.; Panagiotopoulou, A.; Bizimi, V.; Haynes, M. S.; Love, S.; Kallergi, M.
2017-11-01
The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia™ Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert’s GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert’s but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
2017-03-01
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Changing patterns of traumatic bile duct injuries: a review of forty years experience
Huang, Zhi-Qiang; Huang, Xiao-Qiang
2002-01-01
AIM: To summarize the experiences of treating bile duct injuries in 40 years of clinical practice. MATHODS: Based on the experience of more than 40 years of clinical work, 122 cases including a series of 61 bile duct injuries of the Southwest Hospital, Chongqing, and 42 cases (1989-1997) and 19 cases (1998-2001) of the General Hospital of PLA, Beijing, were reviewed with special reference to the pattern of injury. A series of cases of the liver and the biliary tract injuries following interventional therapy for hepatic tumors, most often hemangioma of the liver, were collected. Chinese medical literature from 1995 to 1999 dealing with 2742 traumatic bile duct strictures were reviewed. RESULTS: There was a changing pattern of the bile duct injury. Although most of the cases of bile duct injuries resulted from open cholecystectomy. Other types of trauma such as laparoscopic cholecystectomy (LC) and hepatic surgery were increased in recent years. Moreover, serious hepato-biliary injuries following HAE using sclerotic agents such as sodium morrhuate and absolute ethanol for the treatment of hepatic hemangiomas were encountered in recent years. Experiences in how to avoid bile duct injury and to treat traumatic biliary strictures were presented. CONCLUSION: Traumatic bile duct stricture is one of the serious complications of hepato-biliary surgery, its prevalence seemed to be increased in recent years. The pattern of bile duct injury was also changed and has become more complicated. Interventional therapy with sclerosing agents may cause serious hepatobiliary complications and should be avoided. PMID:11833062
Laparoscopic bile duct injury: understanding the psychology and heuristics of the error.
Dekker, Sidney W A; Hugh, Thomas B
2008-12-01
Bile duct injury is an important unsolved problem of laparoscopic cholecystectomy, occurring with unacceptable frequency even in the hands of experienced surgeons. This suggests that a systemic predisposition to the injury is intrinsic to cholecystectomy and indicates that an analysis of the psychology and heuristics of surgical decision-making in relation to duct identification may be a guide to prevention. Review of published reports on laparoscopic bile duct injury from 1997 to 2007 was carried out. An analysis was also carried out of the circumstances of the injuries in 49 patients who had transection of an extrahepatic bile duct and who were referred for reconstruction or were assessed in a medicolegal context. Special emphasis was placed on identifying the possible psychological aspects of duct misidentification. Review of published work showed an emphasis on the technical aspects of correct identification of the cystic duct, with few papers addressing the heuristics and psychology of surgical decision-making during cholecystectomy. Duct misidentification was the cause of injury in 42 out of the 49 reviewed patients (86%). The injury was not recognized at operation in 70% and delay in recognition persisted into the postoperative period in 57%. Underestimation of risk, cue ambiguity and visual misperception ('seeing what you believe') were important factors in misidentification. Delay in recognition of the injury is a feature consistent with cognitive fixation and plan continuation, which help construct and sustain the duct misidentification during the operation and beyond. Changing the 'culture' of cholecystectomy is probably the most effective strategy for preventing laparoscopic bile duct injury, especially if combined with new technical approaches and an understanding of the heuristics and psychology of the duct misidentification error. Training of surgeons for laparoscopic cholecystectomy should emphasize the need to be alert for cues that the incorrect duct is being dissected or that a bile duct injury might have occurred. Surgeons may also be trained to accept the need for plan modification, to seek cues that refute a given hypothesis and to apply 'stopping rules' for modifying or converting the operation.
Intraluminal measurement of papillary duct urine pH, in vivo: a pilot study in the swine kidney.
Handa, Rajash K; Lingeman, James E; Bledsoe, Sharon B; Evan, Andrew P; Connors, Bret A; Johnson, Cynthia D
2016-06-01
We describe the in vivo use of an optic-chemo microsensor to measure intraluminal papillary duct urine pH in a large mammal. Fiber-optic pH microsensors have a tip diameter of 140-µm that allows insertion into papillary Bellini ducts to measure tubule urine proton concentration. Anesthetized adult pigs underwent percutaneous nephrolithotomy to access the lower pole of the urinary collecting system. A flexible nephroscope was advanced towards an upper pole papilla with the fiber-optic microsensor contained within the working channel. The microsensor was then carefully inserted into Bellini ducts to measure tubule urine pH in real time. We successfully recorded tubule urine pH values in five papillary ducts from three pigs (1 farm pig and 2 metabolic syndrome Ossabaw pigs). Our results demonstrate that optical microsensor technology can be used to measure intraluminal urine pH in real time in a living large mammal. This opens the possibility for application of this optical pH sensing technology in nephrolithiasis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Characterization of flow in a scroll duct
NASA Technical Reports Server (NTRS)
Begg, E. K.; Bennett, J. C.
1985-01-01
A quantitative, flow visualization study was made of a partially elliptic cross section, inward curving duct (scroll duct), with an axial outflow through a vaneless annular cutlet. The working fluid was water, with a Re(d) of 40,000 at the inlet to the scroll duct, this Reynolds number being representative of the conditions in an actual gas turbine scroll. Both still and high speed moving pictures of fluorescein dye injected into the flow and illuminated by an argon ion laser were used to document the flow. Strong secondary flow, similar to the secondary flow in a pipe bend, was found in the bottom half of the scroll within the first 180 degs of turning. The pressure field set up by the turning duct was strong enough to affect the inlet flow condition. At 90 degs downstream, the large scale secondary flow was found to be oscillatory in nature. The exit flow was nonuniform in the annular exit. By 270 degs downstream, the flow appeared unorganized with no distinctive secondary flow pattern. Large scale structures from the upstream core region appeared by 90 degs and continued through the duct to reenter at the inlet section.
Large Eddy Simulation of Ducted Propulsors in Crashbac
NASA Astrophysics Data System (ADS)
Jang, Hyunchul; Mahesh, Krishnan
2008-11-01
Flow around a ducted marine propulsor is computed using the large eddy simulation methodology under crashback conditions. Crashback is an operating condition where a propulsor rotates in the reverse direction while the vessel moves in the forward direction. It is characterized by massive flow separation and highly unsteady propeller loads, which affect both blade life and maneuverability. The simulations are performed on unstructured grids using the algorithm developed by Mahesh at al. (2004, J. Comput. Phys 197). The flow is computed at the advance ratio J=-0.7 and Reynolds number Re=480,000 based on the propeller diameter. Average and RMS values of the unsteady loads such as thrust, torque, and side force on the blades and duct are compared to experiment. It is seen that even though effects of the duct on thrust and torque are not large enough, those on the side force are significant. The rms of side forces is much higher in the presence of the duct. Pressure distributions on blade surfaces and duct surface are examined and used to explain this effect. This work was supported by the United States Office of Naval Research under ONR Grant N00014-05-1-0003.
Large-Eddy Simulation of Crashback in a Ducted Propulsor
NASA Astrophysics Data System (ADS)
Jang, Hyunchul; Mahesh, Krishnan
2011-11-01
Crashback is an operating condition to quickly stop a propelled vehicle, where the propeller is rotated in the reverse direction to yield negative thrust. The crashback condition is dominated by the interaction of free stream flow with strong reverse flow. Crashback causes highly unsteady loads and flow separation on blade surface. This study uses Large-Eddy Simulation to predict the highly unsteady flow field in crashback for a ducted propulsor. Thrust mostly arises from the blade surface, but most of side-force is generated from the duct surface. Both mean and RMS of pressure are much higher on inner surface of duct, especially near blade tips. This implies that side-force on the ducted propulsor is caused by the blade-duct interaction. Strong tip leakage flow is observed behind the suction side at the tip gap. The physical source of the tip leakage flow is seen to be the large pressure difference between pressure and suction sides. The conditional average during high amplitude event shows that the tip leakage flow and pressure difference are significantly higher. This work is supported by the United States Office of Naval Research under ONR Grant N00014-05-1-0003.
NASA Astrophysics Data System (ADS)
Hou, Hongjuan; Wang, Leilei; Wang, Rui; Yang, Yanzhao
2017-04-01
A turbocharger compressor working in commercial vehicles, especially in some passenger cars, often works together with some pipes with complicated geometry as an air intake system, due to limit of available space in internal combustion engine compartments. These pipes may generate various distortions of physical parameters of the air at the inlet of the compressor and therefore the compressor aerodynamic performance deteriorates. Sometimes, the turbocharging engine fails to work at some operation points. This paper investigates the effects of various swirl distortions induced by different bending-torsional intake ducts on the aerodynamic performance of a turbocharger compressor by both 3D numerical simulations and experimental measurements. It was found that at the outlet of the pipes the different inlet ducts can generate different swirl distortions, twin vortices and bulk-like vortices with different rotating directions. Among them, the bulk-like vortices not only affect seriously the pressure distribution in the impeller domain, but also significantly deteriorate the compressor performance, especially at high flow rate region. And the rotating direction of the bulk-like vortices is also closely associated with the efficiency penalty. Besides the efficiency, the transient flow rate through a single impeller channel, or the asymmetric mass flow crossing the whole impeller, can be influenced by two disturbances. One is from the upstream bending-torsional ducts; other one is from the downstream volute.
Hughes Associates Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, Brad
2013-05-22
This report focuses on the more limiting gasket material (neoprene and viton). The use of polymer based gasketing material has led the DOE to question whether the ducts will be able to maintain structural integrity during a fire.
Breast Cancer Research at NASA
NASA Technical Reports Server (NTRS)
1998-01-01
Isolation of human mammary epithelial cells (HMEC) from breast cancer susceptible tissue; A: Duct element recovered from breast tissue digest. B: Outgrowth of cells from duct element in upper right corner cultured in a standard dish; most cells spontaneousely die during early cell divisions, but a few will establish long-term growth. C: Isolate of long-term frowth HMEC from outgrowth of duct element; cells shown soon after isolation and in early full-cell contact growth in culture in a dish. D: same long-term growth HMEC, but after 3 weeks in late full-cell contact growth in a continuous culture in a dish. Note attempts to reform duct elements but this in two demensions in a dish rather than in three dimensions in tissue. NASA's Marshall Space Flight Center (MSFC) is sponsoring research with Bioreactors, rotating wall vessels designed to grow tissue samples in space, to understand how breast cancer works. This ground-based work studies the growth and assembly of human mammary epithelial cell (HMEC) from breast cancer susceptible tissue. Radiation can make the cells cancerous, thus allowing better comparisons of healthy vs. tunorous tissue. Credit: Dr. Robert Richmond, NASA/Marshall Space Flight Center (MSFC).
Task parameters affecting ergonomic demands and productivity of HVAC duct installation.
Mitropoulos, Panagiotis; Hussain, Sanaa; Guarascio-Howard, Linda; Memarian, Babak
2014-01-01
Mechanical installation workers experience work-related musculoskeletal disorders (WMSDs) at high rates. (1) Quantify the ergonomic demands during HVAC installation, (2) identify the tasks and task parameters that generated extreme ergonomic demands, and (3) propose improvements to reduce the WMSDs among mechanical workers. The study focused on installation of rectangular ductwork components using ladders, and analyzed five operations by two mechanical contractors. Using continuous time observational assessment, the videotaped operations were analyzed along two dimensions: (1) the production tasks and durations, and (2) the ergonomic demands for four body regions (neck, arms/shoulders, back, and knees). The analysis identified tasks with low portion of productive time and high portion of extreme postures, and task parameters that generated extreme postures. Duct alignment was the task with the highest portion of extreme postures. The position of the ladder (angle and distance from the duct) was a task parameter that strongly influenced the extreme postures for back, neck and shoulders. Other contributing factors included the difficulty to reach the hand tools when working on the ladder, the congestion of components in the ceiling, and the space between the duct and the ceiling. The identified tasks and factors provide directions for improvement.
LES of a ducted propeller with rotor and stator in crashback
NASA Astrophysics Data System (ADS)
Jang, Hyunchul; Mahesh, Krishnan
2012-11-01
A sliding interface method is developed for large eddy simulation (LES) of flow past ducted propellers with both rotor and stator. The method is developed for arbitrarily shaped unstructured elements on massively parallel computing platforms. Novel algorithms for searching sliding elements, interpolation at the sliding interface, and data structures for message passing are developed. We perform LES of flow past a ducted propeller with stator blades in the crashback mode of operation, where a marine vessel is quickly decelerated by rotating the propeller in reverse. The unsteady loads predicted by LES are in good agreement with experiments. A highly unsteady vortex ring is observed outside the duct. High pressure fluctuations are observed near the blade tips, which significantly contribute to the side-force. This work is supported by the United States Office of Naval Research.
Meyer, K M; Calfee, M W; Wood, J P; Mickelsen, L; Attwood, B; Clayton, M; Touati, A; Delafield, R
2014-03-01
To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test material coupons and strategically placed at several locations within the duct environment. Various concentrations of H2 O2 and exposure times were evaluated to determine the sporicidal efficacy and minimum exposure needed for decontamination. For the unlined duct, high variability was observed in the recovery of spores between sample locations, likely due to complex, unpredictable flow patterns within the ducts. In comparison, the lined duct exhibited a significant desorption of the H2 O2 following the fumigant dwell period and thus resulted in complete decontamination at all sampling locations. These findings suggest that decontamination of Bacillus spore-contaminated unlined HVAC ducts by hydrogen peroxide fumigation may require more stringent conditions (higher concentrations, longer dwell duration) than internally insulated ductwork. These data may help emergency responders when developing remediation plans during building decontamination. © 2013 The Society for Applied Microbiology This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Móricová, P; Žúbor, P; Kapustová, I; Švecová, I; Danko, J
2013-09-01
Zuskas disease (ZD) is an illness also known as the recurrent subareolar non-puerperal abscess of breast with fistulas of lactiferous ducts or as a periductal mastitis. ZD is rare, but painful chronic disease of breast characterized by local inflammation and evacuation of viscous content from abscess around the nipple. We present a rare form of the non-puerperal mastitis in patients with recurrence of this disease and with the description of management and treatment. The treatment of ZD is often inadequate and it leads to the recurrence of ZD and retraction of the nipple. Definitive treatment of ZD is surgical excision of the fistulation, removing of whole retroareolar fibroglandular tissue, abscess cavity and ductal tissue inside the nipple, including the obstructed ducts. The ratio of patients cured by this method is high, as well as their satisfaction with the final cosmetic effect of the nipple and breast.
Inverse method predicting spinning modes radiated by a ducted fan from free-field measurements.
Lewy, Serge
2005-02-01
In the study the inverse problem of deducing the modal structure of the acoustic field generated by a ducted turbofan is addressed using conventional farfield directivity measurements. The final objective is to make input data available for predicting noise radiation in other configurations that would not have been tested. The present paper is devoted to the analytical part of that study. The proposed method is based on the equations governing ducted sound propagation and free-field radiation. It leads to fast computations checked on Rolls-Royce tests made in the framework of previous European projects. Results seem to be reliable although the system of equations to be solved is generally underdetermined (more propagating modes than acoustic measurements). A limited number of modes are thus selected according to any a priori knowledge of the sources. A first guess of the source amplitudes is obtained by adjusting the calculated maximum of radiation of each mode to the measured sound pressure level at the same angle. A least squares fitting gives the final solution. A simple correction can be made to take account of the mean flow velocity inside the nacelle which shifts the directivity patterns. It consists of modifying the actual frequency to keep the cut-off ratios unchanged.
NASA Astrophysics Data System (ADS)
Wall, Susan M.; Klein, Janet D.
2008-09-01
The inner medullary collecting duct (IMCD) is the final site within the kidney for the reabsorption of urea, water and electrolytes and for the secretion of H+ before the luminal fluid becomes the final urine. Transporters expressed in the IMCD contribute to the generation of the large ion gradients that exist between the interstitium and the collecting duct lumen. Thus, the luminal fluid within the human IMCD can reach an osmolality of 1200 mOsm/kg H2O and a pH of 4. This ability of the human nephron to concentrate and acidify the urine might predispose to stone formation. However, under treatment conditions that predispose to stone formation, such as during hypercalciuria, the kidney mitigates stone formation by reducing solute concentration by reducing H2O reabsorption. Moreover, the kidney attenuates stone formation by tightly controlling acid-base balance, which prevents the bone loss, hypocitraturia and hypercalciuria observed during metabolic acidosis by augmenting net H+ excretion by tightly regulating H+ transporter function and through luminal buffering, particularly with NH3. This article will review the ion transporters present in the mammalian IMCD and their role in the prevention and in the pathogenesis of renal stone formation.
NASA Astrophysics Data System (ADS)
Sudjai, W.; Juntasaro, V.; Juttijudata, V.
2018-01-01
The accuracy of predicting turbulence induced secondary flows is crucially important in many industrial applications such as turbine blade internal cooling passages in a gas turbine and fuel rod bundles in a nuclear reactor. A straight square duct is popularly used to reveal the characteristic of turbulence induced secondary flows which consists of two counter rotating vortices distributed in each corner of the duct. For a rotating duct, the flow can be divided into the pressure side and the suction side. The turbulence induced secondary flows are converted to the Coriolis force driven two large circulations with a pair of additional vortices on the pressure wall due to the rotational effect. In this paper, the Large Eddy Simulation (LES) of turbulence induced secondary flows in a straight square duct is performed using the ANSYS FLUENT CFD software. A dynamic kinetic energy subgrid-scale model is used to describe the three-dimensional incompressible turbulent flows in the stationary and the rotating straight square ducts. The Reynolds number based on the friction velocity and the hydraulic diameter is 300 with the various rotation numbers for the rotating cases. The flow is assumed fully developed by imposing the constant pressure gradient in the streamwise direction. For the rotating cases, the rotational axis is placed perpendicular to the streamwise direction. The simulation results on the secondary flows and the turbulent statistics are found to be in good agreement with the available Direct Numerical Simulation (DNS) data. Finally, the details of the Coriolis effects are discussed.
Kroh, Matthew; Chalikonda, Sricharan; Chand, Bipan; Walsh, R Matthew
2013-01-01
Recent enthusiasm in the surgical community for less invasive surgical approaches has resulted in widespread application of single-incision techniques. This has been most commonly applied in laparoscopic cholecystectomy in general surgery. Cosmesis appears to be improved, but other advantages remain to be seen. Feasibility has been demonstrated, but there is little description in the current literature regarding complications. We report the case of a patient who previously underwent single-incision laparoscopic cholecystectomy for symptomatic gallstone disease. After a brief symptom-free interval, she developed acute pancreatitis. At evaluation, imaging results of ultrasonography and magnetic resonance cholangiopancreatography demonstrated a retained gallbladder with cholelithiasis. The patient was subsequently referred to our hospital, where she underwent further evaluation and surgical intervention. Our patient underwent 4-port laparoscopic remnant cholecystectomy with transcystic common bile duct exploration. Operative exploration demonstrated a large remnant gallbladder and a partially obstructed cystic duct with many stones. Transcystic exploration with balloon extraction resulted in duct clearance. The procedure took 75 minutes, with minimal blood loss. The patient's postoperative course was uneventful. Final pathology results demonstrated a remnant gallbladder with cholelithiasis and cholecystitis. This report is the first in the literature to describe successful laparoscopic remnant cholecystectomy and transcystic common bile duct exploration after previous single-port cholecystectomy. Although inadvertent partial cholecystectomy is not unique to this technique, single-port laparoscopic procedures may result in different and significant complications.
Navier-Stokes analysis and experimental data comparison of compressible flow within ducts
NASA Technical Reports Server (NTRS)
Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.
1992-01-01
Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models. The present study compares results for both the Baldwin-Lomas and k-epsilon turbulence models and is conducted with a refined grid. For the transition duct, two inlet conditions were considered, the first with straight flow and the second with swirling flow. The first case permits examination of the effects of the geometric transition on the flow field, while the second case includes the rotational flow effect characteristic of a gas turbine engine.
Subsonic Flows through S-Ducts with Flow Control
NASA Astrophysics Data System (ADS)
Chen, Yi
An inlet duct of an aircraft connects the air intake mounted on the fuselage to the engine within the aircraft body. The ideal outflow quality of the duct is steady, uniform and of high total pressure. Recently compact S-shaped inlet ducts are drawing more attention in the design of UAVs with short propulsion system. Compact ducts usually involve strong streamwise adverse pressure gradient and transverse secondary flow, leading to large-scale harmful vortical structures in the outflow. To improve the outflow quality modern flow control techniques have to be applied. Before designing successful flow control methods a solid understanding of the baseline flow field with the duct is crucial. In this work the fundamental mechanism of how the three dimensional flow topology evolves when the relevant parameters such as the duct geometry and boundary layer thickness are varied, is studied carefully. Two distinct secondary-flow patterns are identified. For the first time the sensitivity of the flow topology to the inflow boundary layer thickness in long ducts is clearly addressed. The interaction between the transverse motion induced by the transverse pressure gradient and the streamwise separation is revealed as the crucial reason for the various flow patterns existing in short ducts. A non-symmetric flow pattern is identified for the first time in both experiments and simulations in short ducts in which the intensity of the streamwise separation and the transverse invasion are in the same order of magnitude. A theory of energy accumulation and solution bifurcation is used to give a reasonable explanation for this non-symmetry. After gaining the knowledge of where and how the harmful vortical structures are generated several flow control techniques are tested to achieve a better outflow quality. The analysis of the flow control cases also provides a deeper insight into the behavior of the three-dimensional flow within the ducts. The conventional separation control method of Coanda injection is proved to be less effective in short ducts dominated by strong three-dimensional effects. Besides, the injection enhances the energy accumulation in duct with the asymmetric pattern and leads to the amplification of the asymmetry. Vortex generator jets are applied to generate spanwise near-wall motions opposing the transverse invasion and to break the strong interaction between the invasion and the separation. Symmetry is regained successfully.
Jiang, Tianyong; Song, Gangbing
2017-01-01
With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors’ previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct. PMID:28961173
Jiang, Tianyong; Zheng, Junbo; Huo, Linsheng; Song, Gangbing
2017-09-29
With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors' previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct.
A High Frequency Model of Cascade Noise
NASA Technical Reports Server (NTRS)
Envia, Edmane
1998-01-01
Closed form asymptotic expressions for computing high frequency noise generated by an annular cascade in an infinite duct containing a uniform flow are presented. There are two new elements in this work. First, the annular duct mode representation does not rely on the often-used Bessel function expansion resulting in simpler expressions for both the radial eigenvalues and eigenfunctions of the duct. In particular, the new representation provides an explicit approximate formula for the radial eigenvalues obviating the need for solutions of the transcendental annular duct eigenvalue equation. Also, the radial eigenfunctions are represented in terms of exponentials eliminating the numerical problems associated with generating the Bessel functions on a computer. The second new element is the construction of an unsteady response model for an annular cascade. The new construction satisfies the boundary conditions on both the cascade and duct walls simultaneously adding a new level of realism to the noise calculations. Preliminary results which demonstrate the effectiveness of the new elements are presented. A discussion of the utility of the asymptotic formulas for calculating cascade discrete tone as well as broadband noise is also included.
Phillip, Veit; Schwab, Miriam; Haf, David; Algül, Hana
2017-01-01
Pancreatitis is the most common complication of endoscopic retrograde cholangiopancreatography (ERCP). Several patients´ or procedure related risk factors for post-ERCP pancreatitis (PEP) have been suggested. The aim of this study was to validate the risk factors for PEP in a high-volume center. All patients undergoing first time ERCP at a tertiary referral center between December 2010 and October 2013 were retrospectively included. PEP was defined according to the Atlanta Classification. 344 patients were included in the final analysis. The risk to develop PEP was increased in patients with chronic pancreatitis (odds ratio 3.7) and after inadvertent cannulation of the pancreatic duct (odds ratio 2.2), which occurred in 26.5% of the patients. Inadvertent cannulation occurred significantly more frequently in patients with difficult cannulation of the papilla duodeni major (odds ratio 12.7; p<0.001). ERCP on call was associated with an increased risk for difficult cannulation (odds ratio 3.0). Inadvertent cannulation of the pancreatic duct is a procedure related risk factor for PEP. Measurements on preventing inadvertent cannulation of the pancreatic duct should be established and studies on prophylactic measurements should focus particularly on patients with inadvertent cannulation of the pancreatic duct.
Implementation and Validation of an Impedance Eduction Technique
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.; Gerhold, Carl H.
2011-01-01
Implementation of a pressure gradient method of impedance eduction in two NASA Langley flow ducts is described. The Grazing Flow Impedance Tube only supports plane-wave sources, while the Curved Duct Test Rig supports sources that contain higher-order modes. Multiple exercises are used to validate this new impedance eduction method. First, synthesized data for a hard wall insert and a conventional liner mounted in the Grazing Flow Impedance Tube are used as input to the two impedance eduction methods, the pressure gradient method and a previously validated wall pressure method. Comparisons between the two results are excellent. Next, data measured in the Grazing Flow Impedance Tube are used as input to both methods. Results from the two methods compare quite favorably for sufficiently low Mach numbers but this comparison degrades at Mach 0.5, especially when the hard wall insert is used. Finally, data measured with a hard wall insert mounted in the Curved Duct Test Rig are used as input to the pressure gradient method. Significant deviation from the known solution is observed, which is believed to be largely due to 3-D effects in this flow duct. Potential solutions to this issue are currently being explored.
Long-term post-tensioned beam exposure test specimens : final evaluation.
DOT National Transportation Integrated Search
2003-08-01
In the last few years, the effectiveness of cement grout in galvanized or polyethylene ducts, the most widely used corrosion protection system for : multistrand bonded post-tensioned concrete tendons, has been under debate, due to significant tendon ...
Grebe, J.J.
1959-12-15
A reactor which is particularly adapted tu serve as a heat source for a nuclear powered alrcraft or rocket is described. The core of this reactor consists of a porous refractory modera;or body which is impregnated with fissionable nuclei. The core is designed so that its surface forms tapered inlet and outlet ducts which are separated by the porous moderator body. In operation a gaseous working fluid is circulated through the inlet ducts to the surface of the moderator, enters and passes through the porous body, and is heated therein. The hot gas emerges into the outlet ducts and is available to provide thrust. The principle advantage is that tremendous quantities of gas can be quickly heated without suffering an excessive pressure drop.
NASA Technical Reports Server (NTRS)
Kraft, R. E.
1996-01-01
A computational method to predict modal reflection coefficients in cylindrical ducts has been developed based on the work of Homicz, Lordi, and Rehm, which uses the Wiener-Hopf method to account for the boundary conditions at the termination of a thin cylindrical pipe. The purpose of this study is to develop a computational routine to predict the reflection coefficients of higher order acoustic modes impinging on the unflanged termination of a cylindrical duct. This effort was conducted wider Task Order 5 of the NASA Lewis LET Program, Active Noise Control of aircraft Engines: Feasibility Study, and will be used as part of the development of an integrated source noise, acoustic propagation, ANC actuator coupling, and control system algorithm simulation. The reflection coefficient prediction will be incorporated into an existing cylindrical duct modal analysis to account for the reflection of modes from the duct termination. This will provide a more accurate, rapid computation design tool for evaluating the effect of reflected waves on active noise control systems mounted in the duct, as well as providing a tool for the design of acoustic treatment in inlet ducts. As an active noise control system design tool, the method can be used preliminary to more accurate but more numerically intensive acoustic propagation models such as finite element methods. The resulting computer program has been shown to give reasonable results, some examples of which are presented. Reliable data to use for comparison is scarce, so complete checkout is difficult, and further checkout is needed over a wider range of system parameters. In future efforts the method will be adapted as a subroutine to the GEAE segmented cylindrical duct modal analysis program.
Supersonic quasi-axisymmetric vortex breakdown
NASA Technical Reports Server (NTRS)
Kandil, Osama A.; Kandil, Hamdy A.; Liu, C. H.
1991-01-01
An extensive computational study of supersonic quasi-axisymmetric vortex breakdown in a configured circular duct is presented. The unsteady, compressible, full Navier-Stokes (NS) equations are used. The NS equations are solved for the quasi-axisymmetric flows using an implicit, upwind, flux difference splitting, finite volume scheme. The quasi-axisymmetric solutions are time accurate and are obtained by forcing the components of the flowfield vector to be equal on two axial planes, which are in close proximity of each other. The effect of Reynolds number, for laminar flows, on the evolution and persistence of vortex breakdown, is studied. Finally, the effect of swirl ration at the duct inlet is investigated.
Association between shift work and the risk of death from biliary tract cancer in Japanese men.
Lin, Yingsong; Nishiyama, Takeshi; Kurosawa, Michiko; Tamakoshi, Akiko; Kubo, Tatsuhiko; Fujino, Yoshihisa; Kikuchi, Shogo
2015-10-21
There is increasing evidence suggesting that shift work involving night work may increase cancer risk. We examined the association between working rotating shifts and the risk of death from biliary tract cancer among Japanese men who participated in the Japan Collaborative Cohort Study. Of the 46,395 men recruited, 22,224 men aged 40-65 at baseline (1988-1990) who reported working full-time or were self-employed were included in the present analysis. The study subjects were followed through December 31, 2009. Information regarding occupation and lifestyle factors was collected using a self-administered questionnaire. Cox proportional hazard models were used to estimate the hazard ratio (HR) and 95 % confidence interval (CI) for the risk of death from biliary tract cancer in relation to shift work. During a mean 17-year follow-up, we observed 94 biliary tract cancer deaths, including 23 deaths from gallbladder cancer and 71 deaths from extrahepatic bile duct cancer. Overall, shift work was associated with a statistically non-significant increase in the risk of biliary tract cancer, with an HR of 1.50 (95 % CI: 0.81-2.77), among rotating shift workers. When the analysis was limited to extrahepatic bile duct cancer, a significant association appeared, with a multivariable-adjusted HR of 1.93 (95 % CI: 1.00-3.72) for rotating shift workers. Our data indicate that shift work may be associated with increased risk of death from extrahepatic bile duct cancer in this cohort of Japanese men. The association with gallbladder cancer remains unclear because of the small number of deaths.
Numerical study of laminar magneto-convection in a differentially heated square duct
NASA Astrophysics Data System (ADS)
Tassone, A.; Giannetti, F.; Caruso, G.
2017-01-01
Magnetohydrodynamic pressure drops are one of the main issues for liquid metal blanket in fusion reactors. Minimize the fluid velocity at few millimeters per second is one strategy that can be employed to address the problem. For such low velocities, buoyant forces can effectively contribute to drive the flow and therefore must be considered in the blanket design. In order to do so, a CFD code able to represent magneto-convective phenomena is required. This work aims to gauge the capability of ANSYS© CFX-15 to solve such cases. The laminar flow in a differentially heated duct was selected as validation benchmark. A horizontal and uniform magnetic field was imposed over a square duct with a linear and constant temperature gradient perpendicular to the field. The fully developed flow was analyzed for Gr = 105 and Hartmann number (M) ranging from 102 to 103. Both insulating and conducting duct walls were considered. Strong dampening of the flow in the center of the duct was observed, whereas high velocity jets appeared close to the walls parallel to the magnetic field. The numerical results were validated against theoretical and numerical results founding an excellent agreement.
Modeling the compliance of polyurethane nanofiber tubes for artificial common bile duct
NASA Astrophysics Data System (ADS)
Moazeni, Najmeh; Vadood, Morteza; Semnani, Dariush; Hasani, Hossein
2018-02-01
The common bile duct is one of the body’s most sensitive organs and a polyurethane nanofiber tube can be used as a prosthetic of the common bile duct. The compliance is one of the most important properties of prosthetic which should be adequately compliant as long as possible to keep the behavioral integrity of prosthetic. In the present paper, the prosthetic compliance was measured and modeled using regression method and artificial neural network (ANN) based on the electrospinning process parameters such as polymer concentration, voltage, tip-to-collector distance and flow rate. Whereas, the ANN model contains different parameters affecting on the prediction accuracy directly, the genetic algorithm (GA) was used to optimize the ANN parameters. Finally, it was observed that the optimized ANN model by GA can predict the compliance with high accuracy (mean absolute percentage error = 8.57%). Moreover, the contribution of variables on the compliance was investigated through relative importance analysis and the optimum values of parameters for ideal compliance were determined.
Evaluation of a Brayton cycle recuperator after 21,000 hours of ground testing
NASA Technical Reports Server (NTRS)
Moore, T. J.
1979-01-01
A metallographic examination was conducted on a Brayton cycle recuperator and associated ducting after 21,000 hours of ground testing in air. At the hot (turbine) end, the recuperator operated at a nominal temperature of 675 C. The type 347 stainless-steel recuperator performed satisfactorily in the ground test even though the primary working fluid leaked to the atmosphere periodically. The leakage path was located at plate-bar braze joints which cracked as a result of thermal stresses. The welded type 347 stainless steel ducting a type 347/Hastelloy X bellows survived the ground test with no apparent loss of ductility or integrity. Some apparent aging embrittlement was observed in the Hastelloy X ducting but the serviceability was not affected.
Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2013-10-01
This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilationmore » and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.« less
Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2013-10-01
This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation andmore » air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.« less
NASA Technical Reports Server (NTRS)
Hall, Edward J.; Delaney, Robert A.
1993-01-01
The primary objective of this study was the development of a time-marching three-dimensional Euler/Navier-Stokes aerodynamic analysis to predict steady and unsteady compressible transonic flows about ducted and unducted propfan propulsion systems employing multiple blade rows. The computer codes resulting from this study are referred to as ADPAC-AOAR\\CR (Advanced Ducted Propfan Analysis Codes-Angle of Attack Coupled Row). This document is the final report describing the theoretical basis and analytical results from the ADPAC-AOACR codes developed under task 5 of NASA Contract NAS3-25270, Unsteady Counterrotating Ducted Propfan Analysis. The ADPAC-AOACR Program is based on a flexible multiple blocked grid discretization scheme permitting coupled 2-D/3-D mesh block solutions with application to a wide variety of geometries. For convenience, several standard mesh block structures are described for turbomachinery applications. Aerodynamic calculations are based on a four-stage Runge-Kutta time-marching finite volume solution technique with added numerical dissipation. Steady flow predictions are accelerated by a multigrid procedure. Numerical calculations are compared with experimental data for several test cases to demonstrate the utility of this approach for predicting the aerodynamics of modern turbomachinery configurations employing multiple blade rows.
Usefulness and safety of biliary percutaneous transluminal forceps biopsy (PTFB): our experience.
Ierardi, Anna Maria; Mangini, Monica; Fontana, Federico; Floridi, Chiara; De Marchi, Giuseppe; Petrillo, Mario; Capasso, Raffaella; Chini, Claudio; Cocozza, Eugenio; Cuffari, Salvatore; Segato, Sergio; Rotondo, Antonio; Carrafiello, Gianpaolo
2014-03-01
To evaluate the usefulness and safety of percutaneous transluminal forceps biopsy in patients suspected of having a malignant biliary obstruction. Forty consecutive patients (21 men and 19 women; mean age, 71.9 years) underwent forceps biopsy through percutaneous transhepatic biliary access performed to drain bile. Lesions involved the common bile duct (n 8), common hepatic duct (n 18), hilum (n 6), ampullary segment of the common bile duct (n 8) and were biopsied with 7-F biopsy forceps. Final diagnosis was confirmed with pathologic findings at surgery, or clinical and radiologic follow-up. Twenty-one of 40 biopsies resulted in correct diagnosis of malignancy. Thirteen biopsy diagnosis were proved to be true-negative. There were six false-negative and no false-positive diagnoses. Sensitivity, specificity and accuracy in aspecific biliary obstructions were 85%, 100% and 88,7% respectively. Sensitivity of biopsy in malignancies was higher than in benign obstructions (100% vs 68,4%, CI = 95%). Sensitivity was lower in the hilum tract and in the common bile duct than in other sites (CI = 95%). No major complications related to biopsy procedures occurred. Percutaneous transluminal forceps biopsy is a safe procedure, easy to perform through a transhepatic biliary drainage tract, providing high accuracy in the diagnosis of malignant biliary obstructions.
NASA Technical Reports Server (NTRS)
Kandula, Max; Vu, Bruce
2003-01-01
The Launch Systems Testbed (LST) represents the evolution of vibroacoustics research and development work performed at NASA John F. Kennedy Space Center (KSC) over the last 15 years. The LST is located at the Launch Equipment Test Facility (LETF) in the KSC industrial complex. The LETF is operated by Sierra Lobo, Inc., as a member of University-Affiliated Technology Development Contract (USTDC) to KSC Spaceport and Engineering and Technology Directorate (YA), with ASRC Aerospace Corporation as a the prime contractor. Trajectory Simulation Mechanism (TSM) is a major component of the LST, developed specifically to simulate nonstationary acoustic loads on launch pad structures, vehicles, and payloads. TSM enhances the capabilities within LST for simulating launch environments of future vehicles. The scaled launch environments will be used to predict the full-scale launch environment via an appropriate scaling procedure. Air Force Research Laboratory (AFRL) has tasked NASA KSC to perform a basic technology test program in support of developing a low-cost clean pad (incorporating passive mitigation techniques) for future launch vehicles. The overall goal of the program is to develop innovative launch exhaust management systems, which effectively reduce launch acoustic environment with innovative duct designs, while eliminating traditional sound suppression water systems. Passive techniques, such as nontraditional duct geometries, resonators, and diffusers, etc., will be investigated. The overall goals are to advance innovative concepts for a clean pad while developing ideas to reduce transmitted sound via investigation and modeling of jet exhaust acoustic and flow field characteristics. The series of tests outlined in this report represent baseline tests and are geared towards defining the acoustic load environment on the TSM pad for open and closed duct configurations. This report summarizes the cold jet acoustic testing for Mach 2.5 supersonic nitrogen jet issuing from a nozzle with 1-inch exit diameter. Acoustic data, including spectral sound power and Overall Sound Pressure Level (OASPL), are obtained both for a free jet and with the jet flowing through a rigid-walled duct with a J-deflector. The relative performance of closed duct and open duct is evaluated. The results show that the closed duct is superior to the partially open duct, and results in about 3-decibel (dB) noise reduction (near the duct axis) relative to the free jet. The location of the nozzle exit plane (NEP) relative to the duct inlet plane (DIP) has a significant effect on the acoustic field. The results suggest that the location of NEP at 10 inches above the DIP results in reduced acoustic loads relative to 5 inches above the duct inlet and 1 inch into the duct inlet.
NASA Astrophysics Data System (ADS)
Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.
2011-03-01
Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.
Further analyses of laminar flow heat transfer in circular sector ducts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lei, Q.M.; Trupp, A.C.
1989-11-01
Heat transfer in circular sector ducts is often encountered in multipassage tubes. Certain flow characteristics of circular sector ducts for apex angles up to {pi} have been determined as documented by Shah and London (1978). Recently, Lei and Trupp (1989) have more completely analyzed the flow characteristics of fully developed laminar flow for apex angles up to 2{pi}, including the location of the maximum velocity. Heat transfer results of fully developed laminar flow in circular sector ducts are also available for certain boundary conditions. Trupp and Lau (1984) numerically determined the average Nusselt number (Nu{sub T}) for isothermal walls. Eckertmore » et al. (1958) initially derived an analytical expression for the temperature profile for the case of H1. Sparrow and Haji-angles up to {pi}. However, the above work required numerical integration (or equivalent) to obtain a value for Nu{sub H1}. Regarding the H1{sub ad} boundary condition, Date (1974) numerically obtained a limiting value of Nu{sub H1}{sub ad} for the semicircular duct from the prediction of circular tubes containing a twisted tape (straight and nonconducting tape). Hong and Bergles (1976) also reported an asymptotic value of Nu{sub H1}{sub ad} for the semicircular duct from their entrance region solution. Otherwise it appears that there are no published analytical results of Nu{sub H1}{sub ad} for circular sector ducts. The purpose of this technical note is to communicate these results. In addition, a novel series expression for Nu{sub H1} is presented together with results for apex angles up to 2{pi}.« less
Detonation wave compression in gas turbines
NASA Technical Reports Server (NTRS)
Wortman, A.
1986-01-01
A study was made of the concept of augmenting the performance of low pressure ratio gas turbines by detonation wave compression of part of the flow. The concept exploits the constant volume heat release of detonation waves to increase the efficiency of the Brayton cycle. In the models studied, a fraction of the compressor output was channeled into detonation ducts where it was processed by transient transverse detonation waves. Gas dynamic studies determined the maximum cycling frequency of detonation ducts, proved that upstream propagation of pressure pulses represented no problems and determined the variations of detonation duct output with time. Mixing and wave compression were used to recombine the combustor and detonation duct flows and a concept for a spiral collector to further smooth the pressure and temperature pulses was presented as an optional component. The best performance was obtained with a single firing of the ducts so that the flow could be re-established before the next detonation was initiated. At the optimum conditions of maximum frequency of the detonation ducts, the gas turbine efficiency was found to be 45 percent while that of a corresponding pressure ratio 5 conventional gas turbine was only 26%. Comparable improvements in specific fuel consumption data were found for gas turbines operating as jet engines, turbofans, and shaft output machines. Direct use of the detonation duct output for jet propulsion proved unsatisfactory. Careful analysis of the models of the fluid flow phenomena led to the conclusion that even more elaborate calculations would not diminish the uncertainties in the analysis of the system. Feasibility of the concept to work as an engine now requires validation in an engineering laboratory experiment.
In-duct identification of fluid-borne source with high spatial resolution
NASA Astrophysics Data System (ADS)
Heo, Yong-Ho; Ih, Jeong-Guon; Bodén, Hans
2014-11-01
Source identification of acoustic characteristics of in-duct fluid machinery is required for coping with the fluid-borne noise. By knowing the acoustic pressure and particle velocity field at the source plane in detail, the sound generation mechanism of a fluid machine can be understood. The identified spatial distribution of the strength of major radiators would be useful for the low noise design. Conventional methods for measuring the source in a wide duct have not been very helpful in investigating the source properties in detail because their spatial resolution is improper for the design purpose. In this work, an inverse method to estimate the source parameters with a high spatial resolution is studied. The theoretical formulation including the evanescent modes and near-field measurement data is given for a wide duct. After validating the proposed method to a duct excited by an acoustic driver, an experiment on a duct system driven by an air blower is conducted in the presence of flow. A convergence test for the evanescent modes is performed to find the necessary number of modes to regenerate the measured pressure field precisely. By using the converged modal amplitudes, very-close near-field pressure to the source is regenerated and compared with the measured pressure, and the maximum error was -16.3 dB. The source parameters are restored from the converged modal amplitudes. Then, the distribution of source parameters on the driver and the blower is clearly revealed with a high spatial resolution for kR<1.84 in which range only plane waves can propagate to far field in a duct. Measurement using a flush mounted sensor array is discussed, and the removal of pure radial modes in the modeling is suggested.
Scholten, Lianne; van Huijgevoort, Nadine C M; Bruno, Marco J; Fernandez-Del Castillo, Carlos; Satoi, Sohei; Sauvanet, Alain; Wolfgang, Christopher; Fockens, Paul; Chari, Suresh T; Del Chiaro, Marco; van Hooft, Jeanin E; Besselink, Marc G
2018-05-16
The risk of invasive cancer in resected intraductal papillary mucinous neoplasm with main pancreatic duct involvement is 33%-60%. Most guidelines, therefore, advise resection of main duct intraductal papillary mucinous neoplasm and mixed type intraductal papillary mucinous neoplasm in surgically fit patients, although advice on the surgical strategy (partial or total pancreatectomy) differs. We performed a survey amongst international experts to guide the design of future studies and help to prepare for a single international set of guidelines. An online survey including case vignettes was sent to 221 international experts who had published on main duct/mixed type intraductal papillary mucinous neoplasm in the previous decade and to all surgeon and gastroenterologist members of the pancreatic cyst guideline committees of the European Study Group and the International Association of Pancreatology. Overall, 97 experts (67 surgeons, 30 gastroenterologists) from 19 countries replied (44% response rate). Most (93%) worked in an academic hospital, with a median of 15 years' experience with intraductal papillary mucinous neoplasm treatment. In main duct/mixed type intraductal papillary mucinous neoplasm patients with pancreatic duct dilation (>5 mm) in the entire pancreas, 41% (n = 37) advised nonoperative surveillance every 3-6 months, whereas 59% (n = 54) advised operative intervention. Of those who advised operative intervention, 46% (n = 25) would perform a total pancreatectomy and 31% (n = 17) pancreatoduodenectomy with follow-up. No structural differences in advice were seen between surgeons and gastroenterologists, between continents where the respondents lived, and based on years of experience. This international survey identified a clinically relevant lack of consensus in the treatment strategy in main duct/mixed type intraductal papillary mucinous neoplasm among experts. Studies with long-term follow-up including quality of life after partial and total pancreatectomy for main duct/mixed type intraductal papillary mucinous neoplasm are required. Copyright © 2018 Elsevier Inc. All rights reserved.
Tensile and Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Gayda, John
2006-01-01
This paper represents a status report documenting the work on creep of superalloys performed under Project Prometheus. Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, are being screened to compare their respective capabilities for impeller applications. Several wrought superalloys including Hastelloy X, (Haynes International, Inc., Kokomo, IN), Inconel 617, Inconel 740, Nimonic 263, and Incoloy MA956 (Special Metals Corporation, Huntington, WV) are also being screened to compare their capabilities for duct applications. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Conventional tensile and creep tests were performed at temperatures up to 1200 K on specimens extracted from the materials. Initial microstructure evaluations were also undertaken.
Chiorini, John A; Sneyd, James; Suresh, Vinod
2017-01-01
Previous studies have shown that localized delivery of the aquaporin-1 (AQP1) gene to the parotid duct can restore saliva flow in minipigs following irradiation-induced salivary hypofunction. The resulting flow rate and electrochemistry of secreted saliva contradicts current understanding of ductal fluid transport. We hypothesized that changes in expression of ion transport proteins have occurred following AQP1 transfection. We use a mathematical model of ion and fluid transport across the parotid duct epithelial cells to predict the expression profile of ion transporters that are consistent with the experimental measurements of saliva composition and secretion rates. Using a baseline set of parameters, the model reproduces the data for the irradiated, non-AQP1-transfected case. We propose three scenarios which may have occurred after transfection, which differ in the location of the AQP1 gene. The first scenario places AQP1 within nonsecretory cells, and requires that epithelial sodium channel (ENaC) expression is greatly reduced (1.3% of baseline), and ductal bicarbonate concentration is increased from 40.6 to 137.0 mM, to drive water secretion into the duct. The second scenario introduces the AQP1 gene into all ductal cells. The final scenario has AQP1 primarily in the proximal duct cells which secrete water under baseline conditions. We find the change in the remaining cells includes a 95.8% reduction in ENaC expression, enabling us to reproduce all experimental ionic concentrations within 9 mM. These findings provide a mechanistic basis for the observations and will guide the further development of gene transfer therapy for salivary hypofunction. NEW & NOTEWORTHY Following transfection of aquaporin into the parotid ducts of minipigs with salivary hypofunction, the resulting increase in salivary flow rates contradicts current understanding of ductal fluid transport. We show that the change in saliva electrochemistry and flow rate can be explained by changes in expression of ion transporters in the ductal cell membranes, using a mathematical model replicating a single parotid duct. PMID:27932503
Fong, Shelley; Chiorini, John A; Sneyd, James; Suresh, Vinod
2017-02-01
Previous studies have shown that localized delivery of the aquaporin-1 (AQP1) gene to the parotid duct can restore saliva flow in minipigs following irradiation-induced salivary hypofunction. The resulting flow rate and electrochemistry of secreted saliva contradicts current understanding of ductal fluid transport. We hypothesized that changes in expression of ion transport proteins have occurred following AQP1 transfection. We use a mathematical model of ion and fluid transport across the parotid duct epithelial cells to predict the expression profile of ion transporters that are consistent with the experimental measurements of saliva composition and secretion rates. Using a baseline set of parameters, the model reproduces the data for the irradiated, non-AQP1-transfected case. We propose three scenarios which may have occurred after transfection, which differ in the location of the AQP1 gene. The first scenario places AQP1 within nonsecretory cells, and requires that epithelial sodium channel (ENaC) expression is greatly reduced (1.3% of baseline), and ductal bicarbonate concentration is increased from 40.6 to 137.0 mM, to drive water secretion into the duct. The second scenario introduces the AQP1 gene into all ductal cells. The final scenario has AQP1 primarily in the proximal duct cells which secrete water under baseline conditions. We find the change in the remaining cells includes a 95.8% reduction in ENaC expression, enabling us to reproduce all experimental ionic concentrations within 9 mM. These findings provide a mechanistic basis for the observations and will guide the further development of gene transfer therapy for salivary hypofunction. Following transfection of aquaporin into the parotid ducts of minipigs with salivary hypofunction, the resulting increase in salivary flow rates contradicts current understanding of ductal fluid transport. We show that the change in saliva electrochemistry and flow rate can be explained by changes in expression of ion transporters in the ductal cell membranes, using a mathematical model replicating a single parotid duct. Copyright © 2017 the American Physiological Society.
PUMP FOR GASEOUS WORKING FLUIDS
Lipscomb, R.
1948-12-14
A gas pump having a substantially constant rate of flow and a relatively efficient punnping action is described. A number of flexible plates disposed longitudinally in and in contact with a duct are caused to oscillate transversly so as to produce wave-llke deformations of the plates. These deformations are mechanically produced by pushrods and an eccentric gearing arrangement, and are so synchronized that the waves travel from the inlet to the outlet of the duct, and, in so doing, move the gas by positive displacement.
2016-06-01
lowest tens of meters of the MASL from a small Rigid Hull Inflatable Boat (RHIB), or a small work boat, equipped with a tethered profiling system and...ducting Research (CASPER) project. It is capable of making repeated measurements of the lowest tens of meters of the MASL from a small Rigid Hull ...Naval Postgraduate School ONR Office of Naval Research PJ Paulus-Jeske RHIB rigid- hulled inflatable boat R/V research vessel SST sea
NASA Technical Reports Server (NTRS)
Roelke, R. J.; Mclallin, K. L.
1978-01-01
The aerodynamic performance of the compressor-drive turbine of the DOE baseline gas-turbine engine was determined over a range of pressure ratios and speeds. In addition, static pressures were measured in the diffusing transition duct located immediately downstream of the turbine. Results are presented in terms of mass flow, torque, specific work, and efficiency for the turbine and in terms of pressure recovery and effectiveness for the transition duct.
Piezosurgery to perform hyoid bone osteotomies in thyroglossal duct cyst surgery.
Salgarelli, Attilio Carlo; Robiony, Massimo; Consolo, Ugo; Collini, Marco; Bellini, Pierantonio
2011-11-01
Ultrasonic bone-cutting surgery has been introduced as a feasible alternative to the conventional sharp instruments used in craniomaxillofacial surgery because of its precision and safety. The device used is unique in that the cutting action occurs when the tool is used on mineralized tissues and stops on soft tissues. This work describes the use of piezosurgery for hyoid bone resection in thyroglossal duct cyst surgery, briefly reviews the literature on the surgical technique, and reports our experience with 12 cases.
In vivo multiphoton imaging of bile duct ligation
NASA Astrophysics Data System (ADS)
Liu, Yuan; Li, Feng-Chieh; Chen, Hsiao-Chin; Chang, Po-shou; Yang, Shu-Mei; Lee, Hsuan-Shu; Dong, Chen-Yuan
2008-02-01
Bile is the exocrine secretion of liver and synthesized by hepatocytes. It is drained into duodenum for the function of digestion or drained into gallbladder for of storage. Bile duct obstruction is a blockage in the tubes that carry bile to the gallbladder and small intestine. However, Bile duct ligation results in the changes of bile acids in serum, liver, urine, and feces1, 2. In this work, we demonstrate a novel technique to image this pathological condition by using a newly developed in vivo imaging system, which includes multiphoton microscopy and intravital hepatic imaging chamber. The images we acquired demonstrate the uptake, processing of 6-CFDA in hepatocytes and excretion of CF in the bile canaliculi. In addition to imaging, we can also measure kinetics of the green fluorescence intensity.
Characterization of turbulent coherent structures in square duct flow
NASA Astrophysics Data System (ADS)
Atzori, Marco; Vinuesa, Ricardo; Lozano-Durán, Adrián; Schlatter, Philipp
2018-04-01
This work is aimed at a first characterization of coherent structures in turbulent square duct flows. Coherent structures are defined as connected components in the domain identified as places where a quantity of interest (such as Reynolds stress or vorticity) is larger than a prescribed non-uniform threshold. Firstly, we qualitatively discuss how a percolation analysis can be used to assess the effectiveness of the threshold function, and how it can be affected by statistical uncertainty. Secondly, various physical quantities that are expected to play an important role in the dynamics of the secondary flow of Prandtl’s second kind are studied. Furthermore, a characterization of intense Reynolds-stress events in square duct flow, together with a comparison of their shape for analogous events in channel flow at the same Reynolds number, is presented.
Code of Federal Regulations, 2010 CFR
2010-10-01
... degrees C). (c) The room that has the generator set must have intake and exhaust ducts to supply adequate... thermostatically-controlled electric water-jacket heater connected to the final emergency bus is permitted. (e) The... generator set must shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of...
The human skin as a sub-THz receiver - Does 5G pose a danger to it or not?
Betzalel, Noa; Ben Ishai, Paul; Feldman, Yuri
2018-05-01
In the interaction of microwave radiation and human beings, the skin is traditionally considered as just an absorbing sponge stratum filled with water. In previous works, we showed that this view is flawed when we demonstrated that the coiled portion of the sweat duct in upper skin layer is regarded as a helical antenna in the sub-THz band. Experimentally we showed that the reflectance of the human skin in the sub-THz region depends on the intensity of perspiration, i.e. sweat duct's conductivity, and correlates with levels of human stress (physical, mental and emotional). Later on, we detected circular dichroism in the reflectance from the skin, a signature of the axial mode of a helical antenna. The full ramifications of what these findings represent in the human condition are still unclear. We also revealed correlation of electrocardiography (ECG) parameters to the sub-THz reflection coefficient of human skin. In a recent work, we developed a unique simulation tool of human skin, taking into account the skin multi-layer structure together with the helical segment of the sweat duct embedded in it. The presence of the sweat duct led to a high specific absorption rate (SAR) of the skin in extremely high frequency band. In this paper, we summarize the physical evidence for this phenomenon and consider its implication for the future exploitation of the electromagnetic spectrum by wireless communication. Starting from July 2016 the US Federal Communications Commission (FCC) has adopted new rules for wireless broadband operations above 24 GHz (5 G). This trend of exploitation is predicted to expand to higher frequencies in the sub-THz region. One must consider the implications of human immersion in the electromagnetic noise, caused by devices working at the very same frequencies as those, to which the sweat duct (as a helical antenna) is most attuned. We are raising a warning flag against the unrestricted use of sub-THz technologies for communication, before the possible consequences for public health are explored. Copyright © 2018 Elsevier Inc. All rights reserved.
DUCT RETROFIT STRATEGY TO COMPLEMENT A MODULATING FURNACE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
ANDREWS,J.W.
2002-10-02
Some recent work (Walker 2001, Andrews 2002) has indicated that installing a modulating furnace in a conventional duct system may, in many cases, result in a significant degradation in thermal distribution efficiency. The fundamental mechanism was pointed out nearly two decades ago (Andrews and Krajewski 1985). The problem occurs in duct systems that are less-than-perfectly insulated (e.g., R-4 duct wrap) and are located outside the conditioned space. It stems from the fact that when the airflow rate is reduced, as it will be when the modulating furnace reduces its heat output rate, the supply air will have a longer residencemore » time in the ducts and will therefore lose a greater percentage of its heat by conduction than it did at the higher airflow rate. The impact of duct leakage, on the other hand, is not expected to change very much under furnace modulation. The pressures in the duct system will be reduced when the airflow rate is reduced, thus reducing the leakage per unit time. This is balanced by the fact that the operating time will increase in order to meet the same heating load as with the conventional furnace operating at higher output and airflow rates. The balance would be exact if the exponent in the pressure vs. airflow equation were the same as that in the pressure vs. duct leakage equation. Since the pressure-airflow exponent is usually {approx}0.5 and the pressure-leakage exponent is usually {approx}0.6, the leakage loss as a fraction of the load should be slightly lower for the modulating furnace. The difference, however, is expected to be small, determined as it is by a function with an exponent equal to the difference between the above two exponents, or {approx}0.1. The negative impact of increased thermal conduction losses from the duct system may be partially offset by improved efficiency of the modulating furnace itself. Also, the modulating furnace will cycle on and off less often than a single-capacity model, and this may add a small amount (probably in the range 1%-3%) to the thermal distribution efficiency. Nevertheless, the effect of furnace modulation on thermal distribution efficiency, both as calculated and as measured in the laboratory, is quite significant. Although exact quantification of the impact will depend on factors such as climate and the location of the ducts within the structure, impacts in the 15%-25% range are to be expected for ducts located outside the conditioned space, as most residential duct systems are. This is too large a handicap to ignore.« less
A portable fluorescence microscopic imaging system for cholecystectomy
NASA Astrophysics Data System (ADS)
Ye, Jian; Yang, Chaoyu; Gan, Qi; Ma, Rong; Zhang, Zeshu; Chang, Shufang; Shao, Pengfei; Zhang, Shiwu; Liu, Chenhai; Xu, Ronald
2016-03-01
In this paper we proposed a portable fluorescence microscopic imaging system to prevent iatrogenic biliary injuries from occurring during cholecystectomy due to misidentification of the cystic structures. The system consisted of a light source module, a CMOS camera, a Raspberry Pi computer and a 5 inch HDMI LCD. Specifically, the light source module was composed of 690 nm and 850 nm LEDs, allowing the CMOS camera to simultaneously acquire both fluorescence and background images. The system was controlled by Raspberry Pi using Python programming with the OpenCV library under Linux. We chose Indocyanine green(ICG) as a fluorescent contrast agent and then tested fluorescence intensities of the ICG aqueous solution at different concentration levels by our fluorescence microscopic system compared with the commercial Xenogen IVIS system. The spatial resolution of the proposed fluorescence microscopic imaging system was measured by a 1951 USAF resolution target and the dynamic response was evaluated quantitatively with an automatic displacement platform. Finally, we verified the technical feasibility of the proposed system in mouse models of bile duct, performing both correct and incorrect gallbladder resection. Our experiments showed that the proposed system can provide clear visualization of the confluence between the cystic duct and common bile duct or common hepatic duct, suggesting that this is a potential method for guiding cholecystectomy. The proposed portable system only cost a total of $300, potentially promoting its use in resource-limited settings.
Comparison of software models for energy savings from cool roofs
New, Joshua; Miller, William A.; Huang, Yu; ...
2015-06-07
For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savingsmore » to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.« less
Progress on Variable Cycle Engines
NASA Technical Reports Server (NTRS)
Westmoreland, J. S.; Howlett, R. A.; Lohmann, R. P.
1979-01-01
Progress in the development and future requirements of the Variable Stream Control Engine (VSCE) are presented. The two most critical components of this advanced system for future supersonic transports, the high performance duct burner for thrust augmentation, and the low jet coannular nozzle were studied. Nozzle model tests substantiated the jet noise benefit associated with the unique velocity profile possible with a coannular nozzle system on a VSCE. Additional nozzle model performance tests have established high thrust efficiency levels only at takeoff and supersonic cruise for this nozzle system. An experimental program involving both isolated component and complete engine tests has been conducted for the high performance, low emissions duct burner with good results and large scale testing of these two components is being conducted using a F100 engine as the testbed for simulating the VSCE. Future work includes application of computer programs for supersonic flow fields to coannular nozzle geometries, further experimental testing with the duct burner segment rig, and the use of the Variable Cycle Engine (VCE) Testbed Program for evaluating the VSCE duct burner and coannular nozzle technologies.
Nennig, Benoit; Tahar, Mabrouk Ben; Perrey-Debain, Emmanuel
2011-07-01
In the present work, the propagation of sound in a lined duct containing sheared mean flow is studied. Walls of the duct are acoustically treated with absorbent poroelastic foams. The propagation of elasto-acoustic waves in the liner is described by Biot's model. In the fluid domain, the propagation of sound in a sheared mean flow is governed by the Galbrun's equation. The problem is solved using a mixed displacement-pressure finite element formulation in both domains. A 3D implementation of the model has been performed and is illustrated on axisymmetric examples. Convergence and accuracy of the numerical model are shown for the particular case of the modal propagation in a infinite duct containing a uniform flow. Practical examples concerning the sound attenuation through dissipative silencers are discussed. In particular, effects of the refraction effects in the shear layer as well as the mounting conditions of the foam on the transmission loss are shown. The presence of a perforate screen at the air-porous interface is also considered and included in the model. © 2011 Acoustical Society of America
NASA Astrophysics Data System (ADS)
Sovardi, Carlo; Jaensch, Stefan; Polifke, Wolfgang
2016-09-01
A numerical method to concurrently characterize both aeroacoustic scattering and noise sources at a duct singularity is presented. This approach combines Large Eddy Simulation (LES) with techniques of System Identification (SI): In a first step, a highly resolved LES with external broadband acoustic excitation is carried out. Subsequently, time series data extracted from the LES are post-processed by means of SI to model both acoustic propagation and noise generation. The present work studies the aero-acoustic characteristics of an orifice placed in a duct at low flow Mach numbers with the "LES-SI" method. Parametric SI based on the Box-Jenkins mathematical structure is employed, with a prediction error approach that utilizes correlation analysis of the output residuals to avoid overfitting. Uncertainties of model parameters due to the finite length of times series are quantified in terms of confidence intervals. Numerical results for acoustic scattering matrices and power spectral densities of broad-band noise are validated against experimental measurements over a wide range of frequencies below the cut-off frequency of the duct.
NASA Astrophysics Data System (ADS)
Torregrosa, A. J.; Broatch, A.; Margot, X.; García-Tíscar, J.
2016-08-01
An experimental methodology is proposed to assess the noise emission of centrifugal turbocompressors like those of automotive turbochargers. A step-by-step procedure is detailed, starting from the theoretical considerations of sound measurement in flow ducts and examining specific experimental setup guidelines and signal processing routines. Special care is taken regarding some limiting factors that adversely affect the measuring of sound intensity in ducts, namely calibration, sensor placement and frequency ranges and restrictions. In order to provide illustrative examples of the proposed techniques and results, the methodology has been applied to the acoustic evaluation of a small automotive turbocharger in a flow bench. Samples of raw pressure spectra, decomposed pressure waves, calibration results, accurate surge characterization and final compressor noise maps and estimated spectrograms are provided. The analysis of selected frequency bands successfully shows how different, known noise phenomena of particular interest such as mid-frequency "whoosh noise" and low-frequency surge onset are correlated with operating conditions of the turbocharger. Comparison against external inlet orifice intensity measurements shows good correlation and improvement with respect to alternative wave decomposition techniques.
Pancreaticopleural fistula: etiology, treatment and long-term follow-up.
Roberts, Keith J; Sheridan, Maria; Morris-Stiff, Gareth; Smith, Andrew M
2012-04-01
Pancreaticopleural fistula (PPF) are uncommon. Complex multidisciplinary treatment is required due to nutritional compromise and sepsis. This is the first description of long-term follow-up of patients with PPF. Eleven patients with PPF treated at a specialist unit were identified. Causation, investigation, treatment and outcomes were recorded. Pancreatitis was the etiology of the PPF in 9 patients, and in the remaining 2 the PPF developed following distal pancreatectomy. Cross-sectional imaging demonstrated the site of duct disruption in 10 cases, with endoscopic retrograde cholangiopancreatography identifying the final case. Suppression of pancreatic exocrine secretion and percutaneous drainage formed the mainstay of treatment.Five cases resolved following pancreatic duct stent insertion and three patients required surgical treatment for established empyema. There were no complications. In all cases that resolved there has been no recurrence of PPF over a median follow-up of 50 months (range 15-62). PPF is an uncommon event complicating pancreatitis or pancreatectomy; pancreatic duct disruption is the common link. A step-up approach consisting of minimally invasive techniques treats the majority with surgery needed for refractory sepsis.
Pathophysiology, diagnosis and management of nephrogenic diabetes insipidus.
Bockenhauer, Detlef; Bichet, Daniel G
2015-10-01
Healthy kidneys maintain fluid and electrolyte homoeostasis by adjusting urine volume and composition according to physiological needs. The final urine composition is determined in the last tubular segment: the collecting duct. Water permeability in the collecting duct is regulated by arginine vasopressin (AVP). Secretion of AVP from the neurohypophysis is regulated by a complex signalling network that involves osmosensors, barosensors and volume sensors. AVP facilitates aquaporin (AQP)-mediated water reabsorption via activation of the vasopressin V2 receptor (AVPR2) in the collecting duct, thus enabling concentration of urine. In nephrogenic diabetes insipidus (NDI), inability of the kidneys to respond to AVP results in functional AQP deficiency. Consequently, affected patients have constant diuresis, resulting in large volumes of dilute urine. Primary forms of NDI result from mutations in the genes that encode the key proteins AVPR2 and AQP2, whereas secondary forms are associated with biochemical abnormalities, obstructive uropathy or the use of certain medications, particularly lithium. Treatment of the disease is informed by identification of the underlying cause. Here we review the clinical aspects and diagnosis of NDI, the various aetiologies, current treatment options and potential future developments.
NASA Astrophysics Data System (ADS)
Strangeways, H. J.
1981-03-01
The size and position of the regions in the bottomside ionosphere through which downcoming whistlers emerge are estimated using ray-tracing calculations in both summer day and winter night models of the magnetospheric plasma. Consideration is given to the trapping of upgoing whistler-mode waves through both the base and the side of ducts. It is found that for downcoming rays which were trapped in the duct in the summer day model, the limited range of wave-normal angles which can be transmitted from the lower ionosphere to free space below causes the size of the exit point to be considerably smaller than the region of incidence. The exit point is found to be approximately 100 km in size, which agrees with ground-based observations of fairly narrow trace whistlers. For rays trapped in the duct in the winter night model, it is found that the size of the exit point is more nearly the same as the range of final latitudes of the downcoming rays in the lower ionosphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
The builder worked with Building Science Corporation to design ten HERS 53 homes with ICF foundations, foam-sheathed above-grade walls, and high-efficiency furnaces with fresh air intake and jump ducts.
Wan, Ping; Xia, Qiang; Zhang, Jian Jun; Li, Qi Gen; Xu, Ning; Zhang, Ming; Chen, Xiao Song; Han, Long Zhi
2015-10-01
Regeneration of the partial allograft and the growth of children may cause kinking of the biliary tract after pediatric living donor liver transplantation (LDLT), but bile duct kinking after adult LDLT is rarely reported. We herein presented two patients who suffered from anastomotic strictures caused by severe bile duct kinking after LDLT. The first patient was a 57-year-old woman with hepatitis B virus (HBV)-related liver cirrhosis, who developed biliary stricture 5 months after receiving right-lobe LDLT. Subsequently, endoscopic and percutaneous treatments were attempted, but both failed to solve the problem. The second was a 44-year-old woman also having HBV-related liver cirrhosis. Biliary stricture occurred 14 months after LDLT. Likewise, the guide wire failed to pass through the stricture when endoscopic interventions were conducted. Afterwards, both of the two cases underwent reexploration, showing that compensatory hypertrophy of the allografts resulted in kinking and sharp angulation of the bile ducts, and the anastomotic sites were found to be severely stenotic. Finally, re-anastomosis by Roux-en-Y procedure was successfully performed, and long-term stenosis-free survival was achieved in both of them. Our experience suggests that bile duct kinking after LDLT may play a role in the high incidence of anastomotic strictures in adult LDLT recipients, which may also result in the treatment failure of the non-surgical techniques for anastomotic strictures. Re-anastomosis in the form of Roux-en-Y hepaticojejunostomy is an effective surgical option for the treatment of such a condition. © 2015 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
The Reduction of Ducted Fan Engine Noise Via A Boundary Integral Equation Method
NASA Technical Reports Server (NTRS)
Tweed, J.; Dunn, M.
1997-01-01
The development of a Boundary Integral Equation Method (BIEM) for the prediction of ducted fan engine noise is discussed. The method is motivated by the need for an efficient and versatile computational tool to assist in parametric noise reduction studies. In this research, the work in reference 1 was extended to include passive noise control treatment on the duct interior. The BEM considers the scattering of incident sound generated by spinning point thrust dipoles in a uniform flow field by a thin cylindrical duct. The acoustic field is written as a superposition of spinning modes. Modal coefficients of acoustic pressure are calculated term by term. The BEM theoretical framework is based on Helmholtz potential theory. A boundary value problem is converted to a boundary integral equation formulation with unknown single and double layer densities on the duct wall. After solving for the unknown densities, the acoustic field is easily calculated. The main feature of the BIEM is the ability to compute any portion of the sound field without the need to compute the entire field. Other noise prediction methods such as CFD and Finite Element methods lack this property. Additional BIEM attributes include versatility, ease of use, rapid noise predictions, coupling of propagation and radiation both forward and aft, implementable on midrange personal computers, and valid over a wide range of frequencies.
NASA Astrophysics Data System (ADS)
Timar, T.
1981-09-01
A new blowdown system was developed for cleaning debris from the inlet grill of waterjet propulsion system on Boeing hydrofoil boats. A system was required to work with existing waterjet ducts which are open ended. The new blowdown system consists of an abrupt discharge of high pressure compressed air amidst the water inlet duct. It utilizes the open end of the propulsor discharge nozzle as a safety valve. Feasibility was proven by semi-steady state equations and was confirmed by full scale testing. A system was developed and installed and is now fully operational.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... moving devices, including fans, blowers, and jet-type air movers, and all duct work shall be electrically... and explosive solvents with flash points below 80 °F. Work involving such materials shall be done only...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... moving devices, including fans, blowers, and jet-type air movers, and all duct work shall be electrically... and explosive solvents with flash points below 80 °F. Work involving such materials shall be done only...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... moving devices, including fans, blowers, and jet-type air movers, and all duct work shall be electrically... and explosive solvents with flash points below 80 °F. Work involving such materials shall be done only...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... moving devices, including fans, blowers, and jet-type air movers, and all duct work shall be electrically... and explosive solvents with flash points below 80 °F. Work involving such materials shall be done only...
NASA Astrophysics Data System (ADS)
Thompson, W. E.
The behavior of fluids, gas, and mechanical components in turbomachinery is investigated. The prediction of aerodynamically induced vibrations in turbomachinery blading is described, and the measurement of aerodynamic work during fan flutter and the calculation of the vibration of an elastically mounted cylinder from experimental forced oscillation data are discussed. Attention is given to tangential vibration of integral turbine blades due to partial admission and to the effects of an annular fluid on the critical speed of a rotating shaft. The analysis of rotordynamic coefficients for convergent-tapered annular seals is examined and results of studies of fluid forces on a whirling centrifugal impeller in a vaneless diffuser are reported. Finally, the potential interaction between a centrifugal impeller and a vaned diffuser and the excitation of compressor/duct are examined.
Research on Darrieus-type hydraulic turbine for extra-low head hydropower utilization
NASA Astrophysics Data System (ADS)
Furukawa, A.; Watanabe, S.; Okuma, K.
2012-11-01
A Darrieus-type turbine has been investigated for extra-low head hydropower utilization. In the present paper, authors'research on Darrieus-type hydraulic turbine is briefly reviewed. The working principle of Darrieus turbine is explained with advantage of its simple structure, at first. Then the fluid-dynamic difference between rotating and linear motions of a blade in a uniform flow is clarified with guiding principle of high performance design of Darrieus turbine. Cavitation problem is also described. Next, effects of duct-casing, consisting of an intake, runner section and draft tube, are discussed and a simplified structure of Darrieus turbine is shown by installing the inlet nozzle. Finally, in the practical use, an adjustment of inlet nozzle section by lowering the inlet nozzle height is proposed when flow rate is varied temporally and seasonally.
Mohammed, Noor; Pinder, Matthew; Harris, Keith; Everett, Simon M
2016-07-01
Conventional endoscopic duct clearance may not be possible in up to 10%-15% of common bile duct stones (CBDS). Sphincterotomy and biliary drainage by endoprosthesis have for many years been the mainstay of management in irretrievable stones. Recent years have seen the advent of sphincteroplasty or cholangioscopically-guided electrohydraulic lithotripsy (EHL) permitting duct clearance in majority of cases. However, when bile duct clearance is not possible, options include long-term stenting followed by elective stent exchange (ESE) 6-12 monthly or permanent stent insertion (PSI) in selected cases, but it is not clear which management strategy among ESE and PSI is preferable. A retrospective review of all patients in Leeds Teaching Hospitals NHS Trust who underwent plastic stent insertion for biliary access for difficult CBDS from January 2006 to December 2011 was undertaken. Adult patients with irretrievable CBDS who had plastic stent insertions throughout the follow-up period were included. Patients who underwent PSI and ESE annually were retrospectively reviewed to determine the long-term outcomes. A detailed systematic review was also performed, examining the outcomes of CBDS managed with stents. During the study period, 674 patients underwent 1769 biliary-stent-related procedures; of which, 246 patients met our inclusion criteria. 201 patients had subsequent duct clearance. 45 patients were, therefore, included in the final analysis, 28 of whom underwent annual ESEs and 17 PSIs. Patients in the PSI group had higher American Society of Anesthesiologists (ASA) scores compared with the ESE group. In the PSI group, 9/17 patients presented acutely with blocked stents, 5 of whom presented within 12 months. 2/9 patients were severely ill and died within a fortnight following the repeat endoscopic retrograde cholangiopancreatography (ERCP). In the ESE group, 4/28 patients had duct clearance in subsequent ERCPs, 1/28 patient presented with a blocked stent, and no biliary-related deaths were observed. The mean numbers of ERCPs performed were 0.52 and 1.95 in the PSI and ESE groups, respectively. Over 50% of patients treated with long-term stenting re-presented acutely with stent blockage, though many of these were before 12 months, meaning planned stent exchange would not have affected the outcome. Duct clearance using all possible modalities is the preferred option, but where not possible, management with biliary stenting either with elective exchange or permanent stenting remains a possibility for carefully selected patients, though maybe best suited to those with limited life expectancy.
Effects of preferential concentration on direct radiation transmission in a turbulent duct flow
NASA Astrophysics Data System (ADS)
Villafane, Laura; Banko, Andrew; Kim, Ji Hoon; Elkins, Chris; Eaton, John
2017-11-01
Inertial particles in turbulent flows preferentially concentrate, giving rise to spatial and temporal fluctuations of particle number density that affect radiation transmission through the medium. Positive particle correlations enhance direct transmission when compared to the exponential attenuation predicted by the Beer's Law for randomly distributed particles. In the context of a particle based solar receiver, this work studies the effects of preferential concentration and optical depth on direct transmission through a particle laden turbulent duct flow. Time resolved measurements of transmission through the mixture were performed for various particle loadings and Reynolds numbers, thus varying particle correlation lengths, optical depth and concentration fluctuations. These measurements were made using a photodiode to record the transmission of a collimated laser beam along the wall bisector of the duct. A synchronized high-speed camera provided particle positions along most of the beam path. Average and fluctuating radiation transmission results are compared to predictions derived from the imaged number density fields and to simplified analytical models. Simplified models are able to capture the correct trends with varying loading and preferential concentration. This work is funded by the Department of Energy's National Nuclear Security Administration, Grant #DE-NA0002373-1.
Sever, David M; Freeborn, Layla R
2012-03-01
The anterior testicular ducts of squamates transport sperm from the seminiferous tubules to the ductus deferens. These ducts consist of the rete testis, ductuli efferentes, and ductus epididymis. Many histological and a few ultrastructural studies of the squamate reproductive tract exist, but none concern the Hydrophiidae, the sea snakes and sea kraits. In this study, we describe the anterior testicular ducts of six species of hydrophiid snakes as well as representatives from the Elapidae, Homolapsidae, Leptotyphlopidae, and Uropeltidae. In addition, we examine the ultrastructure of these ducts in the yellow-bellied Sea Snake, Pelamis platurus, only the third such study on snakes. The anterior testicular ducts are similar in histology in all species examined. The rete testis is simple squamous or cuboidal epithelium and transports sperm from the seminiferous tubules to the ductuli efferentes in the extratesticular epididymal sheath. The ductuli efferentes are branched, convoluted tubules composed of simple cuboidal, ciliated epithelium, and many species possess periodic acid-Schiff+ granules in the cytoplasm. The ductus epididymis at the light microscopy level appears composed of pseudostratified columnar epithelium. At the ultrastructural level, the rete testis and ductuli efferentes of P. platurus possess numerous small coated vesicles and lack secretory vacuoles. Apocrine blebs in the ductuli efferentes, however, indicate secretory activity, possibly by a constitutive pathway. Ultrastructure reveals three types of cells in the ductus epididymis of P. platurus: columnar principal cells, squamous basal cells, and mitochondria-rich apical cells. This is the first report of apical cells in a snake. In addition, occasional principal cells possess a single cilium, which has not been reported in reptiles previously but is known in some birds. Finally, the ductus epididymis of P. platurus differs from other snakes that have been studied in possession of apical, biphasic secretory vacuoles. All of the proximal ducts are characterized by widening of adjacent plasma membranes into wide intercellular spaces, especially between the principal cells of the ductus epididymis. Our results contribute to a larger, collaborative study of the evolution of the squamate reproductive tract and to the potential for utilizing cellular characters in future phylogenetic inferences. Copyright © 2011 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco
A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.
47 CFR 32.2423 - Buried cable.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2423 Buried cable. (a... of cleaning manholes and ducts in connection with construction work and the cost of permits and...
[Laparoscopic choledochoscopy].
Alecu, L; Marin, A; Corodeanu, Gh; Gulinescu, L
2003-01-01
Of this study was to evaluate the treatment of common bile duct stones (CBDS) by laparoscopic choledochoscopy. Between 1997-2002, 9 patients (with age between 42-75 years) were treated laparoscopic for CBDS: 8 cases with choledocholithiasis; 1 case with pancreatic neoplasm. Laparoscopic choledochoscopy was performed in 7 cases (84.4%). We used the choledochoscope Pentax of 5 mm diameter and with work canal. We performed the CBD exploration with: transcystic approach-1 case; choledochotomy-6 cases. The CBD diameter was between 1.2-1.5 cm. The bile duct stones diameter were between 0.5-1.5 cm. We performed with successfully the laparoscopic choledochoscopy exploration and extraction of CBD stones to all patients. External biliary drainage (transcystic duct and with Kehr-tube) were done systematically. The major complication (choleperitoneum) occurred in 2 cases (28.5%). The occurrence of residual ductal stones was 0. The laparoscopic treatment of choledocholithiasis is feasible, safe and efficient.
Pulsatile pressure driven rarefied gas flow in long rectangular ducts
NASA Astrophysics Data System (ADS)
Tsimpoukis, Alexandros; Valougeorgis, Dimitris
2018-04-01
The pulsatile pressure driven fully developed flow of a rarefied gas through an orthogonal duct is investigated, based on the time-dependent linear Bhatnagar, Gross, and Krook equation, by decomposing the flow into its steady and oscillatory parts. The investigation is focused on the oscillatory part, which is characterized by the gas rarefaction and oscillation parameters, the duct aspect ratio, and the accommodation coefficient. As the oscillation frequency is increased, the amplitude of all macroscopic quantities is decreased, while their phase angle lag is increased reaching the limiting value of π/2. As the gas becomes more rarefied, higher frequencies are needed to trigger this behavior. At small and moderate frequencies, there is a critical degree of gas rarefaction, where a maximum flow rate is obtained. As the duct aspect ratio is decreased and tends to zero, the flow rate and mean wall shear stress amplitudes are increased, while their phase angle lags are slightly affected. The accommodation coefficient has a significant effect on the amplitude and a very weak one on the phase angle of the macroscopic quantities. The computation of the inertia and viscous forces clarifies when the flow consists of only one oscillating viscous region or of two regions, namely, the inviscid piston flow in the core and the oscillating Stokes layer at the wall with the velocity overshooting. Finally, the time average oscillatory pumping power is increased as the oscillation frequency is reduced and its maximum value is one half of the corresponding steady one.
Fan Noise Control Using Herschel-Quincke Resonators
NASA Astrophysics Data System (ADS)
Burdisso, Ricardo A.; Ng, Wing F.
2003-01-01
The research effort proposed for this NASA NRA is mainly experimental. In addition, Virginia Tech is working in partnership with Goodrich Aerospace, Aerostructures Group for the analytical development needed to support the experimental endeavor, i.e. model development, design, and system studies. In this project, Herschel-Quincke (HQ)liner technology experiments will be performed at the NASA Glenn Active Noise Control Fan (ANCF) facility. A schematic of both inlet and aft HQ-liner systems installed in the ANCF rig as well as a picture of the Glenn facility is shown. The main goal is to simultaneously test in both the inlet and bypass duct sections. The by-pass duct will have HQ-systems in both the inner and outer duct walls. The main advantages of performing tests at the ANCF facility are that the effect of the inlet HQ-system on the by-pass HQ-system and vice versa, can be accurately determined from the in-duct modal data. Another significant advantage is that it offers the opportunity to assess (on a common basis) the proposed noise reduction concept on the ANCF rig which in the past has been used for assessing other active and passive noise reduction strategies.
Application of Gr/PMR-15 to commercial aircraft
NASA Technical Reports Server (NTRS)
Postlewaite, J.; Porter, K.; Mclaren, D.
1985-01-01
Following from early experience with polyimides on the SST program and Shuttle aft flap studies the Boeing Company is now working on collaborative programs with its principal nacelle suppliers to pursue the development of Gr/PMR-15 nacelle components. Two programs are currently in effect. The first program is directed specifically towards the flight test and service evaluation at the earliest possible date of a 747 nacelle core cowl structure. The second program seeks to firmly establish the producibility and cost of a 757 thrust reverser C duct in a production environment. The near term objectives of these programs include: (1) the comparison of estimated cost and weight of Gr/PMR-15 versus metal structure, (2) the engine test of representative composite structure, (3) the preliminary design and analysis of the C duct structure, and (4) the preparation of cost data and time schedules for the development and producibility program. In addition to powerplant structure, the propulsion ducting system has shown to be a strong candidate for Gr/PMR-15 application. Currently, the Boeing 747 Organization is evaluating the use of PMR-15 matrix composites to replace nearly 800 lbs of titanium ducting per airplane.
Fan Noise Control Using Herschel-quincke Resonators
NASA Technical Reports Server (NTRS)
Burdisso, Ricardo A.; Ng, Wing F.; Provenza, Andrew (Technical Monitor)
2003-01-01
The research effort proposed for this NASA NRA is mainly experimental. In addition, Virginia Tech is working in partnership with Goodrich Aerospace, Aerostructures Group for the analytical development needed to support the experimental endeavor, i.e. model development, design, and system studies. In this project, Herschel-Quincke (HQ)liner technology experiments will be performed at the NASA Glenn Active Noise Control Fan (ANCF) facility. A schematic of both inlet and aft HQ-liner systems installed in the ANCF rig as well as a picture of the Glenn facility is shown. The main goal is to simultaneously test in both the inlet and bypass duct sections. The by-pass duct will have HQ-systems in both the inner and outer duct walls. The main advantages of performing tests at the ANCF facility are that the effect of the inlet HQ-system on the by-pass HQ-system and vice versa, can be accurately determined from the in-duct modal data. Another significant advantage is that it offers the opportunity to assess (on a common basis) the proposed noise reduction concept on the ANCF rig which in the past has been used for assessing other active and passive noise reduction strategies.
Acoustic propagation in curved ducts with extended reacting wall treatment
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1989-01-01
A finite-element Galerkin formulation was employed to study the attenuation of acoustic waves propagating in two-dimensional S-curved ducts with absorbing walls without a mean flow. The reflection and transmission at the entrance and the exit of a curved duct were determined by coupling the finite-element solutions in the curved duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, the effects of duct length, curvature (duct offset) and absorber thickness were examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. A means of reducing the number of elements in the absorber region was also presented. In addition, for a curved duct, power attenuation contours were examined to determine conditions for maximum acoustic power absorption. Again, wall curvature was found to significantly effect the optimization process.
... PBC; a type of liver disease that destroys bile ducts, which allows bile to stay in the liver and cause damage) ... agonists. It works by decreasing the production of bile in the liver and increasing the removal of ...
Multimode-Optical-Fiber Imaging Probe
NASA Technical Reports Server (NTRS)
Jackson, Deborah
2000-01-01
Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).
Multimode-Optical-Fiber Imaging Probe
NASA Technical Reports Server (NTRS)
Jackson, Deborah
1999-01-01
Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).
Electromagnetic propagation in PEC and absorbing curved S-ducts
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1988-01-01
A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.
NASA Technical Reports Server (NTRS)
Canacci, Victor A.; Braun, M. Jack
1994-01-01
The experimental approach presented here offers a nonintrusive, qualitative and quantitative evaluation of full field flow patterns applicable in various geometries in a variety of fluids. This Full Flow Field Tracking (FFFT) Particle Image Velocimetry (PIV) technique, by means of particle tracers illuminated by a laser light sheet, offers an alternative to Laser Doppler Velocimetry (LDV), and intrusive systems such as Hot Wire/Film Anemometry. The method makes obtainable the flow patterns, and allows quantitative determination of the velocities, accelerations, and mass flows of an entire flow field. The method uses a computer based digitizing system attached through an imaging board to a low luminosity camera. A customized optical train allows the system to become a long distance microscope (LDM), allowing magnifications of areas of interest ranging up to 100 times. Presented in addition to the method itself, are studies in which the flow patterns and velocities were observed and evaluated in three distinct geometries, with three different working fluids. The first study involved pressure and flow analysis of a brush seal in oil. The next application involved studying the velocity and flow patterns in a cowl lip cooling passage of an air breathing aircraft engine using water as the working fluid. Finally, the method was extended to a study in air to examine the flows in a staggered pin arrangement located on one side of a branched duct.
Transition duct assembly with modified trailing edge in turbine system
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMahan, Kevin Weston; Schott, Carl Gerard; Ingram, Clint Luigie
2016-10-04
Transition duct assemblies for turbine systems and turbomachines are provided. In one embodiment, a transition duct assembly includes a plurality of transition ducts disposed in a generally annular array and comprising a first transition duct and a second transition duct. Each of the plurality of transition ducts includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of each transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct assembly further includes anmore » aerodynamic structure defined by the passages of the first transition duct and the second transition duct. The aerodynamic structure includes a pressure side, a suction side, and a trailing edge, the trailing edge having a modified aerodynamic contour.« less
Aeroacoustics of automotive vents
NASA Astrophysics Data System (ADS)
Guérin, S.; Thomy, E.; Wright, M. C. M.
2005-08-01
This paper studies the generation of noise by car ventilation systems whose outlet rates are controlled by a butterfly valve and whose directions are controlled by grilles. First the noise created by the valve alone is analysed with the theory formulated by Nelson and Morfey for spoiler-generated noise in-duct flow. To confirm this theory the fluctuating force experienced by the valve is measured experimentally and the mean drag force is deduced from analytical work presented by Sarpkaya. Then the noise generated by the grille and its effect on sound transmission is investigated. Finally, it is shown that a strong and complex interaction between the wake shed behind the valve and the grille occurs when both elements are placed close together. This is responsible for an overall increase in the noise level although some sound reduction is measured at low frequency. It is found that moving the valve further upstream can reduce the noise by several decibels.
Thermography and Sonic Anemometry to Analyze Air Heaters in Mediterranean Greenhouses
López, Alejandro; Valera, Diego L.; Molina-Aiz, Francisco; Peña, Araceli
2012-01-01
The present work has developed a methodology based on thermography and sonic anemometry for studying the microclimate in Mediterranean greenhouses equipped with air heaters and polyethylene distribution ducts to distribute the warm air. Sonic anemometry allows us to identify the airflow pattern generated by the heaters and to analyze the temperature distribution inside the greenhouse, while thermography provides accurate crop temperature data. Air distribution by means of perforated polyethylene ducts at ground level, widely used in Mediterranean-type greenhouses, can generate heterogeneous temperature distributions inside the greenhouse when the system is not correctly designed. The system analyzed in this work used a polyethylene duct with a row of hot air outlet holes (all of equal diameter) that expel warm air toward the ground to avoid plant damage. We have observed that this design (the most widely used in Almería's greenhouses) produces stagnation of hot air in the highest part of the structure, reducing the heating of the crop zone. Using 88 kW heating power (146.7 W·m−2) the temperature inside the greenhouse is maintained 7.2 to 11.2 °C above the outside temperature. The crop temperature (17.6 to 19.9 °C) was maintained above the minimum recommended value of 10 °C. PMID:23202025
Thermography and sonic anemometry to analyze air heaters in Mediterranean greenhouses.
López, Alejandro; Valera, Diego L; Molina-Aiz, Francisco; Peña, Araceli
2012-10-16
The present work has developed a methodology based on thermography and sonic anemometry for studying the microclimate in Mediterranean greenhouses equipped with air heaters and polyethylene distribution ducts to distribute the warm air. Sonic anemometry allows us to identify the airflow pattern generated by the heaters and to analyze the temperature distribution inside the greenhouse, while thermography provides accurate crop temperature data. Air distribution by means of perforated polyethylene ducts at ground level, widely used in Mediterranean-type greenhouses, can generate heterogeneous temperature distributions inside the greenhouse when the system is not correctly designed. The system analyzed in this work used a polyethylene duct with a row of hot air outlet holes (all of equal diameter) that expel warm air toward the ground to avoid plant damage. We have observed that this design (the most widely used in Almería's greenhouses) produces stagnation of hot air in the highest part of the structure, reducing the heating of the crop zone. Using 88 kW heating power (146.7 W ∙ m(-2)) the temperature inside the greenhouse is maintained 7.2 to 11.2 °C above the outside temperature. The crop temperature (17.6 to 19.9 °C) was maintained above the minimum recommended value of 10 °C.
Hasegawa, Satoshi; Moriwaki, Yoshihiro; Uchida, Keiji; Kosuge, Takayuki; Yamamoto, Toshiro; Sugiyama, Mitsugi
2004-01-01
Post-traumatic hepatic pseudoaneurysms are rare. We report a very unusual case of bile duct injury complicated with an asymptomatic post-traumatic hepatic pseudoaneurysm. A previously healthy 17-year-old man sustained multiple traumas after a motorcycle accident. Post-traumatic hepatic pseudoaneurysms were detected after blunt liver injury. The rapid growth of the pseudoaneurysms in the hepatic hilus compressed the common hepatic bile duct and caused extrahepatic bile leakage at the lateral lobe. At first, the hepatic arterial pseudoaneurysms were embolized and bile leakage at the left lobe was treated conservatively. Finally, however, segment 2 and 3 partial liver resection should have been performed to stop the bile leakage. Post-traumatic pseudoaneurysm should be ruled out, in addition to the presence of biliary tract injury, if the intraperitoneal bile leakage appears after liver injury.
Design study of an air pump and integral lift engine ALF-504 using the Lycoming 502 core
NASA Technical Reports Server (NTRS)
Rauch, D.
1972-01-01
Design studies were conducted for an integral lift fan engine utilizing the Lycoming 502 fan core with the final MQT power turbine. The fan is designed for a 12.5 bypass ratio and 1.25:1 pressure ratio, and provides supercharging for the core. Maximum sea level static thrust is 8370 pounds with a specific fuel consumption of 0.302 lb/hr-lb. The dry engine weight without starter is 1419 pounds including full-length duct and sound-attenuating rings. The engine envelope including duct treatment but not localized accessory protrusion is 53.25 inches in diameter and 59.2 inches long from exhaust nozzle exit to fan inlet flange. Detailed analyses include fan aerodynamics, fan and reduction gear mechanical design, fan dynamic analysis, engine noise analysis, engine performance, and weight analysis.
NASA Technical Reports Server (NTRS)
Wang, Ten-See; Chyu, Ming-King
1993-01-01
Forced flow through channels connected by sharp bends is frequently encountered in various rocket and gas turbine engines. For example, the transfer ducts, the coolant channels surround the combustion chamber, the internal cooling passage in a blade or vane, the flow path in the fuel element of a nuclear rocket engine, the flow around a pressure relieve valve piston, and the recirculated base flow of multiple engine clustered nozzles. Transport phenomena involved in such a flow passage are complex and considered to be very different from those of conventional turning flow with relatively mild radii of curvature. While previous research pertaining to this subject has been focused primarily on the experimental heat transfer, very little analytical work is directed to understanding the flowfield and energy transport in the passage. Therefore, the primary goal of this paper is to benchmark the predicted wall heat fluxes using a state-of-the-art computational fluid dynamics (CFD) formulation against those of measurement for a rectangular turn duct. Other secondary goals include studying the effects of turning configurations, e.g., the semi-circular turn, and the rounded-corner turn, and the effect of system rotation. The computed heat fluxes for the rectangular turn duct compared favorably with those of the experimental data. The results show that the flow pattern, pressure drop, and heat transfer characteristics are different among the three turning configurations, and are substantially different with system rotation. Also demonstrated in this work is that the present computational approach is quite effective and efficient and will be suitable for flow and thermal modeling in rocket and turbine engine applications.
Turbofan aft duct suppressor study program listing and user's guide
NASA Technical Reports Server (NTRS)
Joshi, M. C.; Kraft, R. E.
1983-01-01
A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.
Two-stage vs single-stage management for concomitant gallstones and common bile duct stones
Lu, Jiong; Cheng, Yao; Xiong, Xian-Ze; Lin, Yi-Xin; Wu, Si-Jia; Cheng, Nan-Sheng
2012-01-01
AIM: To evaluate the safety and effectiveness of two-stage vs single-stage management for concomitant gallstones and common bile duct stones. METHODS: Four databases, including PubMed, Embase, the Cochrane Central Register of Controlled Trials and the Science Citation Index up to September 2011, were searched to identify all randomized controlled trials (RCTs). Data were extracted from the studies by two independent reviewers. The primary outcomes were stone clearance from the common bile duct, postoperative morbidity and mortality. The secondary outcomes were conversion to other procedures, number of procedures per patient, length of hospital stay, total operative time, hospitalization charges, patient acceptance and quality of life scores. RESULTS: Seven eligible RCTs [five trials (n = 621) comparing preoperative endoscopic retrograde cholangiopancreatography (ERCP)/endoscopic sphincterotomy (EST) + laparoscopic cholecystectomy (LC) with LC + laparoscopic common bile duct exploration (LCBDE); two trials (n = 166) comparing postoperative ERCP/EST + LC with LC + LCBDE], composed of 787 patients in total, were included in the final analysis. The meta-analysis detected no statistically significant difference between the two groups in stone clearance from the common bile duct [risk ratios (RR) = -0.10, 95% confidence intervals (CI): -0.24 to 0.04, P = 0.17], postoperative morbidity (RR = 0.79, 95% CI: 0.58 to 1.10, P = 0.16), mortality (RR = 2.19, 95% CI: 0.33 to 14.67, P = 0.42), conversion to other procedures (RR = 1.21, 95% CI: 0.54 to 2.70, P = 0.39), length of hospital stay (MD = 0.99, 95% CI: -1.59 to 3.57, P = 0.45), total operative time (MD = 12.14, 95% CI: -1.83 to 26.10, P = 0.09). Two-stage (LC + ERCP/EST) management clearly required more procedures per patient than single-stage (LC + LCBDE) management. CONCLUSION: Single-stage management is equivalent to two-stage management but requires fewer procedures. However, patient’s condition, operator’s expertise and local resources should be taken into account in making treatment decisions. PMID:22791952
14 CFR 29.1103 - Induction systems ducts and air duct systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...
14 CFR 25.1103 - Induction system ducts and air duct systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts and air duct systems. 25.1103 Section 25.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Induction System § 25.1103 Induction system ducts and air duct...
Proctor, John P.
2001-02-27
A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.
Proctor, John P.; deKieffer, Robert C.
2001-01-01
A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.
Parametric study of electromagnetic waves propagating in absorbing curved S ducts
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1989-01-01
A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.
Komo, Toshiaki; Oishi, Koichi; Kohashi, Toshihiko; Hihara, Jun; Kanou, Mikihiro; Nakashima, Akira; Kaneko, Mayumi; Mukaida, Hidenori; Hirabayashi, Naoki
2018-06-04
Intraductal papillary mucinous neoplasms (IPMNs) occasionally involve formation of fistulas with other adjacent organs. Pancreatobiliary fistulas associated with IPMNs are rare, but affected patients often develop obstructive jaundice and cholangitis. A 79-year-old man was referred to our hospital for evaluation of abnormal biliary enzymes. Contrast-enhanced computed tomography and endoscopic retrograde cholangiopancreatography demonstrated multiple cystic lesions with septa in the pancreatic head and fistulas between the cystic lesions and common bile duct. The clinical diagnosis was pancreatobiliary fistula associated with a mixed-type IPMN and accompanying obstructive jaundice. The patient underwent subtotal stomach-preserving pancreaticoduodenectomy. The resected specimen showed fistulas between the cystic lesions and common bile duct. Histopathological examination showed that the main and branch ducts of the pancreatic head were dilated and filled with mucus. The epithelia of the pancreatic ducts revealed papillary proliferation and an invasive adenocarcinoma arising from an intraductal neoplasm. Immunohistochemistry examination showed CDX2- and MUC2-positive reactions. The final diagnosis was an intraductal papillary mucinous carcinoma of the intestinal-type. The patient remained disease-free for 9 months postoperatively. The causes of death in patients who have pancreatobiliary fistulas associated with IPMNs without resection are cholangitis or hepatic insufficiency. Nonoperative treatment is limited for cases with obstructive jaundice. It is necessary to prevent obstructive jaundice and cholangitis due to a large quantity of mucinous material. Surgical resection should be considered, if possible, in patients with pancreatobiliary fistulas associated with IPMNs. A better prognosis is expected with prevention of obstructive jaundice or cholangitis. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Numerical investigation of the effects of ITD length on low pressure nozzle
NASA Astrophysics Data System (ADS)
Liu, Guang; Liu, Jun; Liu, Hongrui; Wang, Pei; Du, Qiang
2017-06-01
The advantage of high efficiency, low SFC (Specific Fuel Consumption), ultra-high bypass ratio turbofan engine attracts more and more attention in modern commercial engine. The intermediate turbine duct (ITD), which connects high pressure turbine (HPT) with low pressure turbine (LPT), has a critical impact on the overall performance of turbine by guiding flow coming from HPT to LPT without too much loss. Therefore, it becomes more and more urgent to master the technique of designing aggressive, even super-aggressive ITD. Much more concerns have been concentrated on the duct. However, in order to further improve turbine, LPT nozzle is arranged into ITD to shorten low pressure axle. With such design concept, it is obvious that LPT nozzle flow field is easily influenced by upstream duct structure, but receives much less interests on the contrary. In this paper, numerical method is used to investigate the effects of length of ITD with upstream swirl blades on LPT nozzle. Nine models with the same swirl and nozzle blades, while the length of ITD is the only parameter to be changed, will be discussed. Finally, several conclusions and advices for designers are summarized. After changing axial length of ducts, inlet and outlet flow field of nozzle differs, correspondingly. On the other hand, the shearing stress on nozzle blade (suction and pressure) surface presents individual feature under various inlet flow. In addition to that, "Clocking-like effect" is described in this paper, which will contribute much to the pressure loss and should be paid enough attention.
Evaluation of Flush-Mounted, S-Duct Inlets With Large Amounts of Boundary Layer Ingestion
NASA Technical Reports Server (NTRS)
Berrier, Bobby L.; Morehouse, Melissa B.
2003-01-01
A new high Reynolds number test capability for boundary layer ingesting inlets has been developed for the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. Using this new capability, an experimental investigation of four S-duct inlet configurations with large amounts of boundary layer ingestion (nominal boundary layer thickness of about 40% of inlet height) was conducted at realistic operating conditions (high subsonic Mach numbers and full-scale Reynolds numbers). The objectives of this investigation were to 1) develop a new high Reynolds number, boundary-layer ingesting inlet test capability, 2) evaluate the performance of several boundary layer ingesting S-duct inlets, 3) provide a database for CFD tool validation, and 4) provide a baseline inlet for future inlet flow-control studies. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on duct exit diameter) from 5.1 million to a fullscale value of 13.9 million, and inlet mass-flow ratios from 0.39 to 1.58 depending on Mach number. Results of this investigation indicate that inlet pressure recovery generally decreased and inlet distortion generally increased with increasing Mach number. Except at low Mach numbers, increasing inlet mass-flow increased pressure recovery and increased distortion. Increasing the amount of boundary layer ingestion (by decreasing inlet throat height and increasing inlet throat width) or ingesting a boundary layer with a distorted profile decreased pressure recovery and increased distortion. Finally, increasing Reynolds number had almost no effect on inlet distortion but increased inlet recovery by about one-half percent at a Mach number near cruise.
Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators
NASA Astrophysics Data System (ADS)
Deng, Lei; Zhou, Ning; Chen, Yi-shui; Tu, Yu
2017-11-01
Shielding body of the high-energy medical electron accelerators is always penetrated by ducts, which would influence the shielding capability of local barrier. In order to quantitatively analyze the duct's impact on shielding of the photoneutron from 15 MV accelerators, the ambient dose equivalent rate and energy spectrum at the center of a typical duct and the external mouth of duct were calculated based on MCNP program for the first time. The results demonstrate that leakage neutrons at the external mouth of duct are mainly thermal neutron, and its dose rate is decreased with the increase of the intersection angle between duct and wall as well as the reduction of duct diameter. When a duct in a diameter no more than 30 cm penetrates the wall unidirectionally and the inclined Angle (θ) is 60°, neutron dose rate at the external mouth of duct could meet the requirements of protection. At last, according to the calculation results, some suggestions are proposed for the shielding design of ducts in walls.
Anomalous pancreatico-biliary ductal union with cystic dilatation of the bile duct.
Richer, J P; Faure, J P; Morichau-Beauchant, M; Dugue, T; Maillot, N; Kamina, P; Carretier, M
1998-01-01
We report, in an adult, an asymptomatic association between cystic dilation of the bile duct (type IV A in Todani's classification) and anomalous pancreatico-biliary ductal union (APBD) with stones in a long common channel. In APBD, the connection between the common bile duct and the main pancreatic duct is located outside the duodenal wall andis therefore not under the influence of the sphincter of Boyden. An abnormally long common channel is in excess of 15 mm. Two types of convergence anomalies are defined according to whether the bile duct opens into the main pancreatic duct (BP) or the main pancreatic duct into the bile duct (PB). In APBD, there is probably a reverse pressure gradient between the bile and pancreatic ducts, with regurgitation of pancreatic juice into the bile duct, repeated attacks of cholangitis, stenosis and cystic dilatation. A long common channel is associated with a higher incidence of carcinoma of the gall bladder of the bile duct.
Characterization of the secondary flow in hexagonal ducts
NASA Astrophysics Data System (ADS)
Marin, O.; Vinuesa, R.; Obabko, A. V.; Schlatter, P.
2016-12-01
In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Reτ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondary flow integrated over the cross-sectional area
Effects of Bifurcations on Aft-Fan Engine Nacelle Noise
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Farassat, Fereidoun; Pope, D. Stuart; Vatsa, Veer N.
2004-01-01
Aft-fan engine nacelle noise is a significant factor in the increasingly important issue of aircraft community noise. The ability to predict such noise within complex duct geometries is a valuable tool in studying possible noise attenuation methods. A recent example of code development for such predictions is the ducted fan noise propagation and radiation code CDUCT-LaRC. This work focuses on predicting the effects of geometry changes (i.e. bifurcations, pylons) on aft fan noise propagation. Beginning with simplified geometries, calculations show that bifurcations lead to scattering of acoustic energy into higher order modes. In addition, when circumferential mode number and the number of bifurcations are properly commensurate, bifurcations increase the relative importance of the plane wave mode near the exhaust plane of the bypass duct. This is particularly evident when the bypass duct surfaces include acoustic treatment. Calculations involving more complex geometries further illustrate that bifurcations and pylons clearly affect modal content, in both propagation and radiation calculations. Additionally, results show that consideration of acoustic radiation results may provide further insight into acoustic treatment effectiveness for situations in which modal decomposition may not be straightforward. The ability of CDUCT-LaRC to handle complex (non-axisymmetric) multi-block geometries, as well as axially and circumferentially segmented liners, allows investigation into the effects of geometric elements (bifurcations, pylons).
Investigation of the sound generation mechanisms for in-duct orifice plates.
Tao, Fuyang; Joseph, Phillip; Zhang, Xin; Stalnov, Oksana; Siercke, Matthias; Scheel, Henning
2017-08-01
Sound generation due to an orifice plate in a hard-walled flow duct which is commonly used in air distribution systems (ADS) and flow meters is investigated. The aim is to provide an understanding of this noise generation mechanism based on measurements of the source pressure distribution over the orifice plate. A simple model based on Curle's acoustic analogy is described that relates the broadband in-duct sound field to the surface pressure cross spectrum on both sides of the orifice plate. This work describes careful measurements of the surface pressure cross spectrum over the orifice plate from which the surface pressure distribution and correlation length is deduced. This information is then used to predict the radiated in-duct sound field. Agreement within 3 dB between the predicted and directly measured sound fields is obtained, providing direct confirmation that the surface pressure fluctuations acting over the orifice plates are the main noise sources. Based on the developed model, the contributions to the sound field from different radial locations of the orifice plate are calculated. The surface pressure is shown to follow a U 3.9 velocity scaling law and the area over which the surface sources are correlated follows a U 1.8 velocity scaling law.
Sound Insulation in a Hollow Pipe with Subwavelength Thickness
NASA Astrophysics Data System (ADS)
Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun
2017-03-01
Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers.
Sound Insulation in a Hollow Pipe with Subwavelength Thickness
Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun
2017-01-01
Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers. PMID:28272486
Sound Insulation in a Hollow Pipe with Subwavelength Thickness.
Zhang, Hai-Long; Zhu, Yi-Fan; Liang, Bin; Yang, Jing; Yang, Jun; Cheng, Jian-Chun
2017-03-08
Suppression of the transmission of undesired sound in ducts is a fundamental issue with wide applications in a great variety of scenarios. Yet the conventional ways of duct noise control have to rely on mismatched impedance or viscous dissipation, leading the ducts to have ventilation capability weakened by inserted absorbers or a thick shell to accommodate bulky resonators. Here we present a mechanism for insulating sound transmission in a hollow pipe with subwavelength thickness, by directly reversing its propagating direction via anomalous reflection at the flat inner boundary with well-designed phase profile. A metamaterial-based implementation is demonstrated both in simulation and in experiment, verifying the theoretical prediction on high-efficient sound insulation at the desired frequencies by the resulting device, which has a shell as thin as 1/8 wavelength and an entirely open passage that maintains the continuity of the background medium. We have also investigated the potential of our scheme to work in broadband by simply cascading different metamaterial unit cells. Without the defects of blocked path and bulky size of existing sound insulators, we envision our design will open new route to sound insulation in ducts and have deep implication in practical applications such as designs of ventilation fans and vehicle silencers.
Lightweight Valve Closes Duct Quickly
NASA Technical Reports Server (NTRS)
Fournier, Walter L.; Burgy, N. Frank
1991-01-01
Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.
A Model for Shear Layer Effects on Engine Noise Radiation
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Farassat, F.; Pope, D. Stuart; Vatsa, V.
2004-01-01
Prediction of aircraft engine noise is an important aspect of addressing the issues of community noise and cabin noise control. The development of physics based methodologies for performing such predictions has been a focus of Computational Aeroacoustics (CAA). A recent example of code development in this area is the ducted fan noise propagation and radiation code CDUCT-LaRC. Included within the code is a duct radiation model that is based on the solution of FfowcsWilliams-Hawkings (FW-H) equation with a penetrable data surface. Testing of this equation for many acoustic problems has shown it to provide generally better results than the Kirchhoff formula for moving surfaces. Currently, the data surface is taken to be the inlet or exhaust plane for inlet or aft-fan cases, respectively. While this provides reasonable results in many situations, these choices of data surface location lead to a few limitations. For example, the shear layer between the bypass ow and external stream can refract the sound waves radiated to the far field. Radiation results can be improved by including this effect, as well as the rejection of the sound in the bypass region from the solid surface external to the bypass duct surrounding the core ow. This work describes the implementation, and possible approximation, of a shear layer boundary condition within CDUCT-LaRC. An example application also illustrates the improvements that this extension offers for predicting noise radiation from complex inlet and bypass duct geometries, thereby providing a means to evaluate external treatments in the vicinity of the bypass duct exhaust plane.
Image-guided intervention in the human bile duct using scanning fiber endoscope system
NASA Astrophysics Data System (ADS)
Seibel, Eric J.; Jo, Javier A.; Melville, C. David; Johnston, Richard S.; Naumann, Christopher R.; Saunders, Michael D.
2012-01-01
Bile duct cancers are increasing in frequency while being difficult to diagnose. Currently available endoscopic imaging devices used in the biliary tree are low resolution with poor image quality, leading to inadequate evaluation of indeterminate biliary strictures. However, a new ultrathin and flexible cholangioscope system has been successfully demonstrated in a human subject. This mini-cholangioscope system uses a scanning fiber endoscope (SFE) as a forward-imaging guidewire, dimensions of 1.2-mm diameter and 3-m length. Full color video (500-line resolution at 30Hz) is the standard SFE imaging mode using spiral scanning of red, green, and blue laser light at low power. Image-guided operation of the biopsy forceps was demonstrated in healthy human bile ducts with and without saline flushing. The laser-based video imaging can be switched to various modes to enhance tissue markers of disease, such as widefield fluorescence and enhanced spectral imaging. In parallel work, biochemical discrimination of tissue health in pig bile duct has been accomplished using fiberoptic delivery of pulsed UV illumination and time-resolved autofluorescence spectroscopic measurements. Implementation of time-resolved fluorescence spectroscopy for biochemical assessment of the bile duct wall is being done through a secondary endoscopic channel. Preliminary results indicate that adequate SNR levels (> 30 dB) can be achieved through a 50 micron fiber, which could serve as an optical biopsy probe. The SFE is an ideal mini-cholangioscope for integration of both tissue and molecular specific image contrast in the future. This will provide the physician with unprecedented abilities to target biopsy locations and perform endoscopically-guided therapies.
Handbook on Special Works. Technological Lines of Industrial Enterprises. Part 1,
1979-10-16
notching it perpealicalaz to longitudinal axis at the-depth not less than 0.8 D. duct ot in the- sample/specimen with a length of 20-50 mm, cut off froe the...4" kl/cma (U 3555-62). 6-40 6-01-3 1-3 50-70 8&-100 4- 258 6-a 6-7 Keys (tq.mQts Mae oil steel.. 121. carbide brand 20. (1alyGof b-C14JS/ rna #,ks. DOC...rolling irom aluminum and aluminum alloys, in form and state of material divide into: ducts circular anneidlau (4), uardened/tempered and naturally aged (T
Apparatus for supplying conditioned air at a substantially constant temperature and humidity
NASA Technical Reports Server (NTRS)
Obler, H. D. (Inventor)
1980-01-01
The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.
NASA Astrophysics Data System (ADS)
Yadav, Rupesh J.; Kore, Sandeep S.; Joshi, Prathamesh S.
2018-05-01
The experimental and numerical Nusselt number and friction factor investigation for turbulent flow through a non-circular duct with twisted-tape inserts have been presented. The non-circular ducts include square, hexagonal duct. The results of non-circular ducts are compared with circular duct. All the ducts have same equivalent diameter. The twist ratios used for the experiment are Y = 3.5, 4.5, 5.5 and 6.5. Experiments were carried out on square duct, hexagonal duct and circular duct. The Reynolds number lied between 10,000 and 1, 05,000. The present study is restricted to the flow of air at Pr = 0.7 only and within a narrow temperature range of 40 to 75 ΟC, within which the compressible nature of air can be neglected. The results reveal that, both Nusselt number and friction factor increases as the side of non-circular duct increases. Maximum Nusselt number and friction factor is obtained in case of circular duct with twisted tape. Further the correlations of Nu and f are given for different non circular duct with twisted tape insert for engineering applications for the turbulent regime. Since the thermal performance factor (η) is observed to be within the range of 0.8 to 1.13 for both circular and noncircular ducts, the overall benefit of using twisted tape in the flow field shall nevertheless be marginal.
Visitor center flight room,detail of modern soffit and original ribbedconcrete ...
Visitor center flight room,detail of modern soffit and original ribbed-concrete including original integrated duct work, view to northwest - Wright Brothers National Memorial Visitor Center, Highway 158, Kill Devil Hills, Dare County, NC
Froman, D P; Rhoads, D D
2012-10-01
The objectives of the present work were 3-fold. First, a new method for estimating daily sperm production was validated. This method, in turn, was used to evaluate testis output as well as deferent duct throughput. Next, this analytical approach was evaluated in 2 experiments. The first experiment compared left and right reproductive tracts within roosters. The second experiment compared reproductive tract throughput in roosters from low and high sperm mobility lines. Standard curves were constructed from which unknown concentrations of sperm cells and sperm nuclei could be predicted from observed absorbance. In each case, the independent variable was based upon hemacytometer counts, and absorbance was a linear function of concentration. Reproductive tracts were excised, semen recovered from each duct, and the extragonadal sperm reserve determined by multiplying volume by sperm cell concentration. Testicular sperm nuclei were procured by homogenization of a whole testis, overlaying a 20-mL volume of homogenate upon 15% (wt/vol) Accudenz (Accurate Chemical and Scientific Corporation, Westbury, NY), and then washing nuclei by centrifugation through the Accudenz layer. Daily sperm production was determined by dividing the predicted number of sperm nuclei within the homogenate by 4.5 d (i.e., the time sperm with elongated nuclei spend within the testis). Sperm transit through the deferent duct was estimated by dividing the extragonadal reserve by daily sperm production. Neither the efficiency of sperm production (sperm per gram of testicular parenchyma per day) nor deferent duct transit differed between left and right reproductive tracts (P > 0.05). Whereas efficiency of sperm production did not differ (P > 0.05) between low and high sperm mobility lines, deferent duct transit differed between lines (P < 0.001). On average, this process required 2.2 and 1.0 d for low and high lines, respectively. In summary, we developed and then tested a method for quantifying male reproductive tract throughput. This method makes the study of semen production amenable to systems biology.
T-tube drainage versus primary closure after laparoscopic common bile duct exploration.
Gurusamy, Kurinchi Selvan; Koti, Rahul; Davidson, Brian R
2013-06-21
T-tube drainage may prevent bile leak from the biliary tract following bile duct exploration and it offers post-operative access to the bile ducts for visualisation and exploration. Use of T-tube drainage after laparoscopic common bile duct (CBD) exploration is controversial. To assess the benefits and harms of T-tube drainage versus primary closure after laparoscopic common bile duct exploration. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until April 2013. We included all randomised clinical trials comparing T-tube drainage versus primary closure after laparoscopic common bile duct exploration. Two of four authors independently identified the studies for inclusion and extracted data. We analysed the data with both the fixed-effect and the random-effects model meta-analyses using Review Manager (RevMan) Analysis. For each outcome we calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence intervals (CI) based on intention-to-treat analysis. We included three trials randomising 295 participants: 147 to T-tube drainage versus 148 to primary closure. All trials had a high risk of bias. No one died during the follow-up period. There was no significant difference in the proportion of patients with serious morbidity (17/147 (weighted percentage 11.3%) in the T-tube drainage versus 9/148 (6.1%) in the primary closure group; RR 1.86; 95% CI 0.87 to 3.96; three trials), and no significant difference was found in the serious morbidity rates (weighted serious morbidity rate = 97 events per 1000 patients) in participants randomised to T-tube drainage versus serious morbidity rate = 61 events per 1000 patients in the primary closure group; RR 1.59; 95% CI 0.66 to 3.83; three trials). Quality of life was not reported in any of the trials. The operating time was significantly longer in the T-tube drainage group compared with the primary closure group (MD 21.22 minutes; 95% CI 12.44 minutes to 30.00 minutes; three trials). The hospital stay was significantly longer in the T-tube drainage group compared with the primary closure group (MD 3.26 days; 95% CI 2.49 days to 4.04 days; three trials). According to one trial, the participants randomised to T-tube drainage returned to work approximately eight days later than the participants randomised to the primary closure group (P < 0.005). T-tube drainage appears to result in significantly longer operating time and hospital stay as compared with primary closure without any evidence of benefit after laparoscopic common bile duct exploration. Based on currently available evidence, there is no justification for the routine use of T-tube drainage after laparoscopic common bile duct exploration in patients with common bile duct stones. More randomised trials comparing the effects of T-tube drainage versus primary closure after laparoscopic common bile duct exploration may be needed. Such trials should be conducted with low risk of bias, assessing the long-term beneficial and harmful effects including long-term complications such as bile stricture and recurrence of common bile duct stones.
T-tube drainage versus primary closure after open common bile duct exploration.
Gurusamy, Kurinchi Selvan; Koti, Rahul; Davidson, Brian R
2013-06-21
Between 5% and 11% of people undergoing cholecystectomy have common bile duct stones. Stones may be removed at the time of cholecystectomy by opening and clearing the common bile duct. The optimal technique is unclear. The aim is to assess the benefits and harms of T-tube drainage versus primary closure without biliary stent after open common bile duct exploration for common bile duct stones. We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until April 2013. We included all randomised clinical trials comparing T-tube drainage versus primary closure after open common bile duct exploration. Two of four authors independently identified the studies for inclusion and extracted data. We analysed the data with both the fixed-effect and the random-effects model using Review Manager (RevMan) analyses. For each outcome we calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence interval (CI) based on intention-to-treat analysis. We included six trials randomising 359 participants, 178 to T-tube drainage and 181 to primary closure. All trials were at high risk of bias. There was no significant difference in mortality between the two groups (4/178 (weighted percentage 1.2%) in the T-tube group versus 1/181 (0.6%) in the primary closure group; RR 2.25; 95% CI 0.55 to 9.25; six trials). There was no significant difference in the serious morbidity rate between the two groups (24/136 (weighted serious morbidity rate, 145 events per 1000 patients) in the T-tube group versus 9/136 (weighted serious morbidity rate, 66 events per 1000 patients) in the primary closure group; RaR 2.19; 95% CI 0.98 to 4.91; four trials). Quality of life and return to work were not reported in any of the trials. The operating time was significantly longer in the T-tube drainage group compared with the primary closure group (MD 28.90 minutes; 95% CI 17.18 to 40.62 minutes; one trial). The hospital stay was significantly longer in the T-tube drainage group compared with the primary closure group (MD 4.72 days; 95% CI 0.83 days to 8.60 days; five trials). T-tube drainage appeared to result in significantly longer operating time and hospital stay compared with primary closure without any apparent evidence of benefit on clinically important outcomes after open common bile duct exploration. Based on the currently available evidence, there is no justification for the routine use of T-tube drainage after open common bile duct exploration in patients with common bile duct stones. T-tube drainage should not be used outside well designed randomised clinical trials. More randomised trials comparing the effects of T-tube drainage versus primary closure after open common bile duct exploration may be needed. Such trials should be conducted with low risk of bias and assessing the long-term beneficial and harmful effects of T-tube drainage, including long-term complications such as bile stricture and recurrence of common bile duct stones.
... Patients & Visitors Health Library Institutes & Departments Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Advertising Policy Bile Duct Exploration Common bile duct exploration is ...
Trypsin level in gallbladder bile and ductitis and width of the cystic duct.
Vracko, J; Wiechel, K L
2000-01-01
The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P < 0.001) and wider cystic ducts (P < 0.001) with more pronounced signs of chronic ductitis. The obtained results strongly suggest that the increased trypsin level, a sign of reflux of pancreatic juice, caused changes in the cystic duct that facilitate gallstone migration, which also ought to render a transcystic stone extraction feasible.
CT differentiation of mucin-producing cystic neoplasms of the liver from solitary bile duct cysts.
Kim, Hyoung Jung; Yu, Eun Sil; Byun, Jae Ho; Hong, Seung-Mo; Kim, Kyoung Won; Lee, Jong Seok; Kim, So Yeon
2014-01-01
The purpose of this study was to identify the CT features required for differentiating mucin-producing cystic neoplasms of the liver (mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct) from solitary bile duct cysts. CT images of pathologically confirmed mucinous cystic neoplasms (n = 15), cyst-forming intraductal papillary neoplasms of the bile duct (n = 16), and solitary bile duct cysts (n = 31) were reviewed. Analysis of the CT findings included shape, presence of septa, location of septa (peripheral vs central), thickness of septa (thin vs thick), mosaic pattern, mural nodules, intracystic debris, calcification, upstream bile duct dilatation, downstream bile duct dilatation, and communication between a cystic lesion and the bile duct. The maximum size of a cystic lesion and the maximum size of the largest mural nodule were measured. The presence of septa, central septa, mural nodules, upstream bile duct dilatation, and downstream bile duct dilatation were found to be significant CT findings for differentiating mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct from solitary bile duct cysts (p < 0.05 for each finding). When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucin-producing cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively. When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively [corrected]. With the use of specific CT criteria, mucin-producing cystic neoplasms of the liver can be differentiated from solitary bile duct cysts with a high degree of accuracy.
Method and apparatus for duct sealing using a clog-resistant insertable injector
Wang, Duo; Modera, Mark P.
2010-12-14
A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.
NASA Technical Reports Server (NTRS)
Srivastava, R.; Reddy, T. S. R.
1997-01-01
The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.
NASA Astrophysics Data System (ADS)
Ye, Qiang; Hu, Jing; Cheng, Ping; Ma, Zhiqi
2015-11-01
Trade-off between shunt current loss and pumping loss is a major challenge in the design of the electrolyte piping network in a flow battery system. It is generally recognized that longer and thinner ducts are beneficial to reduce shunt current but detrimental to minimize pumping power. Base on the developed analog circuit model and the flow network model, we make case studies of multi-stack vanadium flow battery piping systems and demonstrate that both shunt current and electrolyte flow resistance can be simultaneously minimized by using longer and thicker ducts in the piping network. However, extremely long and/or thick ducts lead to a bulky system and may be prohibited by the stack structure. Accordingly, the intrinsic design trade-off is between system efficiency and compactness. Since multi-stack configurations bring both flexibility and complexity to the design process, we perform systematic comparisons among representative piping system designs to illustrate the complicated trade-offs among numerous parameters including stack number, intra-stack channel resistance and inter-stack pipe resistance. As the final design depends on various technical and economical requirements, this paper aims to provide guidelines rather than solutions for designers to locate the optimal trade-off points according to their specific cases.
Kuriyama, Naohisa; Isaji, Shuji; Tanemura, Akihiro; Iizawa, Yusuke; Kato, Hiroyuki; Murata, Yasuhiro; Azumi, Yoshinori; Kishiwada, Masashi; Mizuno, Shugo; Usui, Masanobu; Sakurai, Hiroyuki
2017-03-01
In the most common surgical procedure for perihilar cholangiocarcinoma, the margin status of the proximal bile duct is determined at the final step. Our procedure, the transhepatic hilar approach, confirms a cancer-negative margin status of the proximal bile duct first. We first performed a partial hepatic parenchymal transection to expose the hilar plate, and then transected the proximal bile duct to confirm margin status. Then, divisions of the hepatic artery and portal vein of the future resected liver are performed, followed by the residual hepatic parenchymal transection. The transhepatic hilar approach offers a wide surgical field for safe resection and reconstruction of the portal vein in the middle of the hepatectomy. We reviewed 23 patients with perihilar cholangiocarcinoma who underwent major hepatectomy using our procedure from 2011 to 2015. A combined vascular resection and reconstruction was carried out in 14 patients (60.9%). R0 resection was achieved in 17 patients (73.9%), and the overall 3-year survival rate was 52.9% (median survival time 52.4 months). The transhepatic hilar approach is useful and practicable regardless of local tumor extension, enabling us to determine tumor resectability and perform safe resection and reconstruction of the portal vein early in the operation.
NASA Technical Reports Server (NTRS)
Berrier, Bobby L.; Carter, Melissa B.; Allan, Brian G.
2005-01-01
An experimental investigation of a flush-mounted, S-duct inlet with large amounts of boundary layer ingestion has been conducted at Reynolds numbers up to full scale. The study was conducted in the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. In addition, a supplemental computational study on one of the inlet configurations was conducted using the Navier-Stokes flow solver, OVERFLOW. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on aerodynamic interface plane diameter) from 5.1 million to 13.9 million (full-scale value), and inlet mass-flow ratios from 0.29 to 1.22, depending on Mach number. Results of the study indicated that increasing Mach number, increasing boundary layer thickness (relative to inlet height) or ingesting a boundary layer with a distorted profile decreased inlet performance. At Mach numbers above 0.4, increasing inlet airflow increased inlet pressure recovery but also increased distortion. Finally, inlet distortion was found to be relatively insensitive to Reynolds number, but pressure recovery increased slightly with increasing Reynolds number.This CD-ROM supplement contains inlet data including: Boundary layer data, Duct static pressure data, performance-AIP (fan face) data, Photos, Tunnel wall P-PTO data and definitions.
Horn, S; Irle, H; Knorr, I; Pottins, I; Rohwetter, M; Schuhknecht, P; Timner, K; Becker, E
2009-06-01
The following guidelines were developed for the medical assessment services of the German pension fund. Starting from day-to-day practice, criteria and attributes to guide decisions for a systematisation of the sociomedical assessment of performance in diseases of the liver and the bile ducts were compiled. The guidelines aim at standardising the sociomedical assessment of performance and help to make the decision-making process more transparent, e. g., for the assessment of applications for decreased earning capacity benefits. The guidelines summarise the typical manifestations of diseases of the liver and the bile ducts and describe the necessary medical information for the sociomedical assessment of performance. Relevant assessment criteria for the medical history, clinical examination, and for diagnostic tests are illustrated. The assessment of the individual's capacity is outlined, taking occupational factors into account. Following the determination of dysfunctions, the remaining abilities and disabilities, respectively, are deduced and compared with occupational demands. Finally, inferences are drawn regarding the occupational capacity of the individual. The guidelines followed from an extended procedure to attain a wide consensus in the setting of the German Pension Fund and an upgraded evidence base.
Collecting Duct Intercalated Cell Function and Regulation
Roy, Ankita; Al-bataineh, Mohammad M.
2015-01-01
Intercalated cells are kidney tubule epithelial cells with important roles in the regulation of acid-base homeostasis. However, in recent years the understanding of the function of the intercalated cell has become greatly enhanced and has shaped a new model for how the distal segments of the kidney tubule integrate salt and water reabsorption, potassium homeostasis, and acid-base status. These cells appear in the late distal convoluted tubule or in the connecting segment, depending on the species. They are most abundant in the collecting duct, where they can be detected all the way from the cortex to the initial part of the inner medulla. Intercalated cells are interspersed among the more numerous segment-specific principal cells. There are three types of intercalated cells, each having distinct structures and expressing different ensembles of transport proteins that translate into very different functions in the processing of the urine. This review includes recent findings on how intercalated cells regulate their intracellular milieu and contribute to acid-base regulation and sodium, chloride, and potassium homeostasis, thus highlighting their potential role as targets for the treatment of hypertension. Their novel regulation by paracrine signals in the collecting duct is also discussed. Finally, this article addresses their role as part of the innate immune system of the kidney tubule. PMID:25632105
Thermal overload characteristics of extruded dielectric cables: Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dima, A.; Katz, C.; Eager, G.S. Jr.
1988-06-01
This report addresses characteristics of thermoset extruded dielectric power cables in the 15--35 kV class, operated under thermal overload conditions. It presents a methodical study to determine the suitability of extruded type cable for operation at elevated temperatures. The results provide utilities with knowledge on the behavior of thermoset insulated cables at temperatures in the 130 to 175/degree/C conductor temperature range. Present industry specifications recommend a maximum emergency conductor temperature of 130/degree/C. The suitability of this temperature and the time it is to be maintained had been questioned. The present report indicates that crosslinked polyethylene and ethylene propylene insulated cable,more » both new and service aged, are suitable for emergency operation during extended periods at 130/degree/C. When these cables are provided with polyvinyl chloride jackets, long term exposure to temperatures greater than 130/degree/C can adversely affect the integrity of the jacket. Investigations on new cables were performed on short samples in ovens and on long samples in simulated ducts in the laboratory and in a typical utility duct bank. Investigations on cables recovered from service were performed in the laboratory with the cables installed in simulated ducts. 10 refs., 49 figs., 73 tabs.« less
Combustor assembly in a gas turbine engine
Wiebe, David J; Fox, Timothy A
2015-04-28
A combustor assembly in a gas turbine engine includes a combustor device, a fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner surrounded by the flow sleeve. The fuel injection system provides fuel to be mixed with the pressurized air and ignited in the liner to create combustion products. The intermediate duct is disposed between the liner and the transition duct so as to define a path for the combustion products to flow from the liner to the transition duct. The intermediate duct is associated with the liner such that movement may occur therebetween, and the intermediate duct is associated with the transition duct such that movement may occur therebetween. The flow sleeve includes structure that defines an axial stop for limiting axial movement of the intermediate duct.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, S.G.; Van Stone, D.A.; Little, R.C.
1993-09-01
Vermiculite, vermiculite coated with magnesia, and activated carbon sorbents have successfully removed NOx (and carbon monoxide and particles) from combustion exhausts in a subscale drone jet engine test cell (JETC), but back pressure so generated elevated the temperature of the JETC and of the engine. The objective of this effort was to explore the feasibility of locating the sorbents in the face of the duct or of baffles parallel to the direction of flow within the ducts. Jet engine test cells (JETCs) are stationary sources of oxides of nitrogen (NOx), soot, and unburned or partially oxidized carbon compounds that formmore » as byproducts of imperfect combustion. Regulation of NOx emissions is being considered for implementation under the Clean Air Act Amendments of 1990. Several principles have been examined as candidate methods to control NOx emissions from JETCs.« less
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-04-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.
30. VIEW WEST IN BASEMENT OF BUILDING 41A; NOTE PLASTIC ...
30. VIEW WEST IN BASEMENT OF BUILDING 41A; NOTE PLASTIC DUCTING WHICH WAS USED TO VENT CORROSIVE FUMES FROM ACID PICKLING AND ELECTROPLATING TANKS - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version
Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-01-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248
Ducted turbine theory with right angled ducts
NASA Astrophysics Data System (ADS)
McLaren-Gow, S.; Jamieson, P.; Graham, J. M. R.
2014-06-01
This paper describes the use of an inviscid approach to model a ducted turbine - also known as a diffuser augmented turbine - and a comparison of results with a particular one-dimensional theory. The aim of the investigation was to gain a better understanding of the relationship between a real duct and the ideal diffuser, which is a concept that is developed in the theory. A range of right angled ducts, which have a rim for a 90° exit angle, were modelled. As a result, the performance of right angled ducts has been characterised in inviscid flow. It was concluded that right angled ducts cannot match the performance of their associated ideal diffuser and that the optimum rotor loading for these turbines varies with the duct dimensions.
Air conditioning system and component therefore distributing air flow from opposite directions
NASA Technical Reports Server (NTRS)
Obler, H. D.; Bauer, H. B. (Inventor)
1974-01-01
The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.
Nagano, Yasuhiko; Matsuo, Kenichi; Gorai, Katsuya; Sugimori, Kazuya; Kunisaki, Chikara; Ike, Hideyuki; Tanaka, Katsuaki; Imada, Toshio; Shimada, Hiroshi
2006-01-01
We present a case of a 72-year-old man with a common bile duct cancer, who was initially believed to have multiple liver metastases based on computed tomography findings, and in whom magnetic resonance cholangiography (MRC) revealed a diagnosis of bile duct hamartomas. At exploration for pancreaticoduodenectomy, liver palpation revealed disseminated nodules at the surface of the liver. These nodules showed gray-white nodular lesions of about 0.5 cm in diameter scattered on the surface of both liver lobes, which were looked like multiple liver metastases from bile duct cancer. Frozen section of the liver biopsy disclosed multiple bile ducts with slightly dilated lumens embedded in the collagenous stroma characteristics of multiple bile duct hamartomas (BDHs). Only two reports have described the MRC features of bile duct hamartomas. Of all imaging procedures, MRC provides the most relevant features for the imaging diagnosis of bile duct hamartomas. PMID:16534895
[Iatrogenic bile duct injuries during the process of laparoscopic cholecystectomy].
Qian, G; Wu, M; Zhang, Y
1995-11-01
Twelve patients with iatrogenic bile duct injuries occurred during laparoscopic cholecystectomy (LC) were treated from June 1992 to May 1994. All the patients underwent re-operation and were cured. The causes and characteristics of the injuries were: (1) perforation of the common hepatic or common bile duct caused by dissecting hook (3 cases); (2) necrosis and perforation of the common hepatic duct due to diathermic injury (1 case); (3) clamping of the common hepatic duct by Ti clip (1 case); (4) secondary high bile duct stricture following a failed end-to-end anastomosis or hepatico-cholangio-jejunostomy of the amputated common hepatic duct (5 cases); (5) delayed high bile duct stricture (2 cases). It is emphasized that the severity of bile duct injuries by LC be should not overlooked, and more experience in this field be accumulated to avoid this serious complication.
Lithium: a versatile tool for understanding renal physiology
Ecelbarger, Carolyn M.
2013-01-01
By virtue of its unique interactions with kidney cells, lithium became an important research tool in renal physiology and pathophysiology. Investigators have uncovered the intricate relationships of lithium with the vasopressin and aldosterone systems, and the membrane channels or transporters regulated by them. While doing so, their work has also led to 1) questioning the role of adenylyl cyclase activity and prostaglandins in lithium-induced suppression of aquaporin-2 gene transcription; 2) unraveling the role of purinergic signaling in lithium-induced polyuria; and 3) highlighting the importance of the epithelial sodium channel (ENaC) in lithium-induced nephrogenic diabetes insipidus (NDI). Lithium-induced remodeling of the collecting duct has the potential to shed new light on collecting duct remodeling in disease conditions, such as diabetes insipidus. The finding that lithium inhibits glycogen synthase kinase-3β (GSK3β) has opened an avenue for studies on the role of GSK3β in urinary concentration, and GSK isoforms in renal development. Finally, proteomic and metabolomic profiling of the kidney and urine in rats treated with lithium is providing insights into how the kidney adapts its metabolism in conditions such as acquired NDI and the multifactorial nature of lithium-induced NDI. This review provides state-of-the-art knowledge of lithium as a versatile tool for understanding the molecular physiology of the kidney, and a comprehensive view of how this tool is challenging some of our long-standing concepts in renal physiology, often with paradigm shifts, and presenting paradoxical situations in renal pathophysiology. In addition, this review points to future directions in research where lithium can lead the renal community. PMID:23408166
Lin, Man-Xia; Ye, Jie-Yi; Tian, Wen-Shuo; Xu, Ming; Zhuang, Bo-Wen; Lu, Ming-De; Xie, Xiao-Yan; Kuang, Ming
2017-04-01
Bile duct injury after ablation of malignant liver tumors (MLTs) was not unusual and should be avoided. However, few studies have focused on evaluating the risk factors for intrahepatic bile duct injury. To evaluate the risk factors for intrahepatic bile duct injury after ablation of MLTs and to evaluate the minimum safe distance for ablating tumors abutting bile ducts. Sixty-five patients with intrahepatic bile duct injury after ablation of MLTs, and 65 controls were recruited. Risk factors for intrahepatic bile duct injury were analyzed. Tumor location was recorded as ≤5 mm (group A), 5-10 mm (group B), and >10 mm (group C) from the right/left main duct or segmental bile duct. Ascites history (P < 0.001), TACE treatment history (P = 0.025), intrahepatic bile duct dilatation before ablation (P < 0.001), and tumor location (P = 0.000) were identified as significant risk factors for intrahepatic bile duct injury. Significant differences in the risk of intrahepatic bile duct injury were found between groups B and C (P = 0.000), but not between groups A and B (P = 0.751). Ascites history (P = 0.002) and tumor location (P < 0.001) were independent predictors with the OR (95 % confidence interval) of 39.31(3.95-391.69) and 16.56 (5.87-46.71), respectively. Bile duct injury after ablation of MLTs was the result of local treatment-related factors combined with the patients' general condition. The minimum safe distance for ablation of tumor abutting a bile duct was 10 mm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jae Woong, E-mail: cooljay@korea.ac.kr; Lu, David S. K., E-mail: dlu@mednet.ucla.edu; Osuagwu, Ferdnand, E-mail: fosuagwu@mednet.ucla.edu
2013-11-07
PurposeTo evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology.Materials and MethodsTwelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE.more » Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks.ResultsNonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts.ConclusionIn the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.« less
Yaprak, Onur; Dayangac, Murat; Akyildiz, Murat; Demirbas, Tolga; Guler, Necdet; Bulutcu, Fisun; Bassullu, Nuray; Akun, Elif; Yuzer, Yildiray; Tokat, Yaman
2012-01-01
Background Biliary complications that developed after right lobe liver transplantation from living donors were studied in a single centre. Methods From 2004 to 2010, 200 consecutive living donor right lobe liver transplantations were performed. The database was evaluated retrospectively. Biliary complications were diagnosed according to clinical, biochemical and radiological tests. The number of biliary ducts in the transplanted graft, the surgical techniques used for anastomosis, biliary strictures and bile leakage rates were analysed. Results Of a total of 200 grafts, 117 invloved a single bile duct, 77 had two bile ducts and in six grafts there were three bile ducts. In 166 transplants, the anastomosis was performed as a single duct to duct, in 21 transplants double duct to ducts, in one transplant, three duct to ducts and in 12 transplants as a Roux-en-Y reconstruction. In all, 40 bile leakages (20%) and 17 biliary strictures (8.5%) were observed in 49 patients resulting in a total of 57 biliary complications (28.5%). Seventeen patients were re-operated (12 as a result of bile leakages and five owing to biliary strictures). Conclusion Identification of more than one biliary orifice in the graft resulted in an increase in the complication rates. In grafts containing multiple orifices, performing multiple duct-to-duct (DD) or Roux-en-Y anastomoses led to a lower number of complications. PMID:22151451
Traumatic resin ducts as indicators of bark beetle outbreaks
R. Justin DeRose; Matthew F. Bekker; James N. Long
2017-01-01
The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...
Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version
Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.
2018-05-22
Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Unresectable Extrahepatic Bile Duct Cancer
Experimental and Computational Evaluation of Flush-Mounted, S-Duct Inlets
NASA Technical Reports Server (NTRS)
Berrier, Bobby L.; Allan, Brian G.
2004-01-01
A new high Reynolds number test capability for boundary layer ingesting inlets has been developed for the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. Using this new capability. an experimental investigation of four S-duct inlet configurations was conducted. A computational study of one of the inlets was also conducted using a Navier-Stokes solver. The objectives of this investigation were to: 1) develop a new high Reynolds number inlet test capability for flush-mounted inlets; 2) provide a database for CFD tool validation; 3) evaluate the performance of S-duct inlets with large amounts of boundary layer ingestion; and 4) provide a baseline inlet for future inlet flow-control studies. Tests were conducted at Mach numbers from 0.25 to 0.83. Reynolds numbers (based on duct exit diameter) from 5.1 million to a full-scale value of 13.9 million, and inlet mass-flow ratios from 0.39 to 1.58 depending on Mach number. Results of the experimental study indicate that inlet pressure recovery generally decreased and inlet distortion generally increased with increasing Mach number. Except at low Mach numbers, increasing inlet mass-flow increased pressure recovery and increased distortion. Increasing the amount of boundary layer ingestion or ingesting a boundary layer with a distorted profile decreased pressure recovery and increased distortion. Finally, increasing Reynolds number had almost no effect on inlet distortion but increased inlet recovery by about one-half percent at a Mach number near cruise. The computational results captured the inlet pressure recovery and distortion trends with Mach number and inlet mass-flow well: the reversal of the pressure recovery trend with increasing inlet mass-flow at low and high Mach numbers was predicted by CFD. However, CFD results were generally more pessimistic (larger losses) than measured experimentally.
Prevention of bile duct injury: the case for incorporating educational theories of expertise.
McKinley, Sophia K; Brunt, L Michael; Schwaitzberg, Steven D
2014-12-01
Over 700,000 laparoscopic cholecystectomies are performed yearly in the US. Despite multiple advantages of laparoscopic surgery, the increased rate of bile duct injury (BDI) compared to the traditional, open approach to cholecystectomy remains problematic. Due to the seriousness of bile duct injury, the time has come for an aggressive educational campaign to better train laparoscopic surgeons in order to reduce the incidence of this life-threatening and expensive complication. We performed a literature review of what is currently known about the causes of bile duct injury during laparoscopic cholecystectomy. Based on these reviews, we identified educational theories of expertise that may be relevant in understanding variable rates of BDI between surgeons. Finally, we applied educational theories of expertise to the problem of BDI in laparoscopic cholecystectomy to propose how to develop and design an effective educational approach for the prevention of BDI. Multiple studies demonstrate that the primary causes of BDI during laparoscopic cholecystectomy are non-technical. Additionally, there exists a learning curve in which the rates of BDI are higher in a surgeon's earlier cases compared to later cases and that some surgeons perform laparoscopic cholecystectomy with significantly fewer injuries than others. Educational theories indicate that interventions that optimize novice to expert development require (1) revealing expert knowledge to novices and (2) scaffolding the mental habits of expert-like learners. BDI is an appropriate target for the application of educational theories of expertise. Designing better educational interventions for the prevention of BDI will require uncovering the hidden knowledge of expert surgeons and incorporating the processes of reinvestment and progressive problem solving that are inherent to expert performance.
NASA Technical Reports Server (NTRS)
Woods, Jody L.
2015-01-01
This paper describes work accomplished to predict the service life of a flexure joint design which is a component of a diffuser duct in the A3 Test Stand, an altitude simulation rocket engine test facility at NASA's Stennis Space Center. The duct has two pressure shells separated by cooling water passages and connected by stiffening ribs and flexure joints. Rocket exhaust flows within the duct and heats the inner pressure shell while the outer pressure shell remains at ambient temperature. The flexure joints allow for differential thermal expansion of the inner and outer pressure shells and are subject to in-service loading by this thermal expansion along with water pressure in the cooling water passage, atmospheric pressure outside the duct, near vacuum conditions within the duct, and vibrational loads from operation of the facility and rocket engine. Figure 1 shows a schematic axisymmetric cross section of the diffuser pressure shells and flexure joints with a zoomed in view of the flexure joint. The flexure joints are expected to eventually fail by fatigue cracking leading to leaks from the cooling water passages to the outside. The zoomed in view in Figure 1 indicates where cracking is expected to occur, namely through a weld bead between two plates of SA-516 Grade 70 steel. This weld bead acts as the fulcrum of the flexure joint and it is clear from inspection of the geometry and loading represented in the zoomed in portion of Figure 1 that inherent in the design there is a severe notch formed between the flexure plate, weld bead, and stiffening ring that will be the site of crack initiation and location from which the crack grows to the outer surface of the weld bead.
Nakamoto, Tetsuji; Shiba, Yoshiki; Hirono, Chikara; Sugita, Makoto; Takemoto, Kazuhisa; Iwasa, Yoshiko; Akagawa, Yasumasa
2002-09-01
Fluid secretion is observed at the openings of ducts in the exocrine gland. It remains unclear whether the ducts are involved in fluid secretion in the salivary glands. In the present study, we investigated the exclusion of fluorescent dye from the duct lumen by carbachol (CCh) in isolated parotid intralobular duct segments to clarify the ability of the ducts for the fluid secretion. When the membrane-impermeable fluorescent dye, sulforhodamine, was added to the superfused extracellular solution, quantitative fluorescence images of the duct lumen were obtained under the optical sectioning at the level of the duct lumen using a confocal laser scanning microscope. CCh decreased the fluorescent intensity in the duct lumen during the superfusion of the fluorescent dye, and CCh flushed out small viscous substances stained with the fluorescent dye from isolated duct lumen, suggesting that CCh might induce fluid secretion in the duct, leading to the clearance of the dye and small stained clumps from the duct lumen. CCh-induced clearance of the fluorescent dye was divided into two phases by the sensitivity to external Ca2+ and methazolamide, an inhibitor for carbonic anhydrase. The initial phase was insensitive to these, and the subsequent late phase was sensitive to these. A major portion in the late phase was inhibited by removal of bicarbonate in the superfusion solution and DPC, but not low concentration of external Cl-, bumetanide or DIDS, suggesting that methazolamide-sensitive production of HCO3-, but not the Cl- uptake mechanism, might contribute to the CCh-induced clearance of the dye from the duct lumen. These results represent the first measurements of fluid movement in isolated duct segments, and suggest that carbachol might evoke fluid secretion possibly through Ca2+-activated, DPC-sensitive anion channels with HCO3- secretion in the rat parotid intralobular ducts.
Carcinoids of the common bile duct: a case report and literature review
Ross, Alison C.; Hurley, James B.; Hay, W. Bruce; Rusnak, Conrad H.; Petrunia, Denis M.
1999-01-01
Carcinoids of the extrahepatic bile ducts and particularly the common bile duct are extremely rare. A 65-year-old woman presented with obstructive jaundice. Laboratory and imaging studies gave results that were consistent with an obstructing lesion in the common bile duct. In this case, a stent was inserted initially to decompress the bile ducts. Subsequently a laparotomy and pancreaticoduodenectomy were performed and a tissue diagnosis of carcinoid of the common bile duct was made. The patient was well with no evidence of recurrence 17 months postoperatively. The authors believe this is the 19th reported case of an extrahepatic bile duct carcinoid. PMID:10071590
Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Mitchell, Scott; Lang, John; Maderas, Dennis; Speth, Joel; Payne, Stephen A.
2000-01-01
A hollow lensing duct to condense (intensify) light using a combination of focusing using a spherical or cylindrical lens followed by reflective waveguiding. The hollow duct tapers down from a wide input side to a narrow output side, with the input side consisting of a lens that may be coated with an antireflective coating for more efficient transmission into the duct. The inside surfaces of the hollow lens duct are appropriately coated to be reflective, preventing light from escaping by reflection as it travels along the duct (reflective waveguiding). The hollow duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials.
Convolution seal for transition duct in turbine system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston
2015-05-26
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature andmore » the adjacent transition duct.« less
... tenderness or inflammation of the clogged duct (periductal mastitis). Mammary duct ectasia most often occurs in women ... that's turned inward (inverted) A bacterial infection called mastitis also may develop in the affected milk duct, ...
Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program
NASA Technical Reports Server (NTRS)
Beckemeyer, R. J.; Sawdy, D. T.
1971-01-01
An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.
22. DETAIL INTERIOR VIEW OF OFFICE, SHOWING ORIGINAL SASH WINDOWS ...
22. DETAIL INTERIOR VIEW OF OFFICE, SHOWING ORIGINAL SASH WINDOWS AND DUCT WORK (OTHER OFFICE INTERIORS ARE GREATLY ALTERED FROM THE ORIGINAL) - Oakland Army Base, Transit Shed, East of Dunkirk Street & South of Burma Road, Oakland, Alameda County, CA
Testing of SLA-561V in NASA-Ames' Turbulent Flow Duct with Augmented Radiative Heating
NASA Technical Reports Server (NTRS)
Sepka, Steven A.; Kornienko, Robert S.; Radbourne, Chris A.
2010-01-01
As part of Mars Science Laboratory s (MSL) heatshield development program, SLA-561 was tested in NASA Ames Turbulent Flow Duct (TFD) Facility. For these tests, the TFD facility was modified to include a ceramic plate located in the wall opposite to the test model. Normally the TFD wall opposite to the test model is water-cooled steel. Installing a noncooled ceramic plate allows the ceramic to absorb convective heating and radiate the energy back to the test model as the plate heats up. This work was an effort to increase the severity of TFD test conditions. Presented here are the results from these tests.
Fan, Wenge; Zhang, Qingsong; Ye, Xun; Fan, Zhijiang
2018-01-01
To observe the morphological changes in paraurethral ducts infected with gonococci in men before and after the administration of the ceftriaxone therapy using high-frequency ultrasound and determine its clinical significance. Thirty-two male patients with gonococcal paraurethral duct infection were enrolled. Their lesions were examined using an ACUSON X300 ultrasound system before and after they were subjected to ceftriaxone therapy. The paraurethral duct was completely closed 3-4 days after ceftriaxone treatment in 30 patients. Paraurethral duct closure began from the blind end and proceeded gradually towards its orifice; during closure, the paraurethral duct diameter showed no apparent change. These 30 patients whose paraurethral ducts closed were considered cured. In the remaining 2 patients, the length and diameter of the paraurethral ducts showed no change before and after ceftriaxone treatment; one patient was unresponsive to ceftriaxone treatment, and the other had secondary dilatation of the paraurethral duct. These 2 patients were cured after surgery. High-frequency ultrasound enables dynamic observation of the morphological changes in paraurethral ducts infected with gonococci before and after ceftriaxone therapy. High-frequency ultrasound can provide valuable information for incision, drainage, and wedge resection of paraurethral ducts. © 2017 S. Karger AG, Basel.
NASA Technical Reports Server (NTRS)
Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.
1997-01-01
This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.; Walker, Iain S.
Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected weekly. The baking test specimens were visually inspected weekly, and the durability was judged by the observed deterioration in terms of brittleness, cracking, flaking and blistering (the terminology used in the UL 181B-FX test procedure).« less
NASA advanced design program. Design and analysis of a radio-controlled flying wing aircraft
NASA Technical Reports Server (NTRS)
1993-01-01
The main challenge of this project was to design an aircraft that will achieve stability while flying without a horizontal tail. The project focused on both the design, analysis and construction of a remotely piloted, elliptical shaped flying wing. The design team was composed of four sub-groups each of which dealt with the different aspects of the design, namely aerodynamics, stability and control, propulsion, and structures. Each member of the team initially researched the background information pertaining to specific facets of the project. Since previous work on this topic was limited, most of the focus of the project was directed towards developing an understanding of the natural instability of the aircraft. Once the design team entered the conceptual stage of the project, a series of compromises had to be made to satisfy the unique requirements of each sub-group. As a result of the numerous calculations and iterations necessary, computers were utilized extensively. In order to visualize the design and layout of the wing, engines and control surfaces, a solid modeling package was used to evaluate optimum design placements. When the design was finalized, construction began with the help of all the members of the project team. The nature of the carbon composite construction process demanded long hours of manual labor. The assembly of the engine systems also required precision hand work. The final product of this project is the Elang, a one-of-a-kind remotely piloted aircraft of composite construction powered by two ducted fan engines.
NASA Astrophysics Data System (ADS)
Gish, Andrew
2015-11-01
Ducts (also called shrouds) have been shown to improve performance of hydrokinetic turbines in some situations, bringing the power coefficient (Cp) closer to the Betz limit. Here we investigate optimization of the duct design as well as the addition of stator blades upstream of the turbine rotor to introduce pre-swirl in the flow. A small scale three-bladed turbine was tested in a towing tank. Three cases (bare turbine, with duct, and with duct and stators) were tested over a range of flow speeds. Important parameters include duct cross-sectional shape, blade-duct gap, stator cross-sectional shape, and stator angle. For each test, Cp was evaluated as a function of tip speed ratio (TSR). Experimental results were compared with numerical simulations. Results indicate that ducts and stators can improve performance at slower flow speeds and lower the stall speed compared to a bare turbine, but may degrade performance at higher speeds. Ongoing efforts to optimize duct and stator configurations will be discussed.
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun
2013-01-01
Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new "papillary-like main pancreatic duct invaginated" techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the "papillary-like main pancreatic duct invaginated" group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the "papillary-like main pancreatic duct invaginated" group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas.
NASA Technical Reports Server (NTRS)
Dittmar, James H.
1988-01-01
A simple barrier shielding model was used to estimate the amount of noise shielding on the fuselage that could result from installing a short duct around a wing-mounted advanced propeller. With the propeller located one-third of the duct length from the inlet, estimates for the maximum blade passing tone attenuation varied from 7 dB for a duct 0.25 propeller diameter long to 16.75 dB for a duct 1 diameter long. Attenuations for the higher harmonics would be even larger because of their shorter wavelengths relative to the duct length. These estimates show that the fuselage noise reduction potential of a ducted compared with an unducted propeller is significant. Even more reduction might occur if acoustic attenuation material were installed in the duct.
Coupled parametric design of flow control and duct shape
NASA Technical Reports Server (NTRS)
Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)
2009-01-01
A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.
NASA Technical Reports Server (NTRS)
Runnels, J. N.; Gupfa, A.
1973-01-01
Augmentor wing ducting system studies conducted on a valveless system configuration that provides cruise thrust from the augmentor nozzles have shown that most of the duct system pressure loss would occur in the strut-wing duct y-junction and the wing duct-augmentor lobe nozzles. These components were selected for development testing over a range of duct Mach numbers and pressure ratios to provide a technical basis for predicting installed wing thrust loading and for evaluating design wing loading of a particular wing aspect ratios. The flow characteristics of ducting components with relatively high pressure loss coefficients were investigated. The turbulent pressure fluctuations associated with flows at high Mach numbers were analyzed to evaluate potential duct fatigue problems.
Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki
2009-03-01
The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.
Voluntary and involuntary ligature of the bile duct in iatrogenic injuries: a nonadvisable approach.
Mercado, Miguel Angel; Chan, Carlos; Jacinto, Juan Carlos; Sanchez, Norberto; Barajas, Alexandra
2008-06-01
Bile duct injuries related to laparoscopic and/or open cholecystectomy are a frequent finding and require surgical treatment. Complete obstruction is due to either intentionally or unintentionally placed ligatures or clips. The intentional application is usually performed to "facilitate identification of the duct by bile duct dilation." Considering that we are a national referral center for such injuries, we decided to analyze our cases of voluntary and involuntary duct ligation after iatrogenic bile duct injury. We reviewed the files of patients with voluntary or involuntary bile duct ligation. Results of preoperative evaluation of the ducts, operative treatment, and postoperative results were analyzed. A total of 413 patients were included. Forty-five patients presented with complete obstruction. In 15 cases, the ligature was intentional, and in 30 cases, occlusion was involuntary. Bile duct dilation (>10 mm) was demonstrated in one case of voluntary (6%) and three cases of involuntary ligations (10%). The remaining cases in both groups had no duct dilation and developed necrosis at the blinded duct and leakage proximal to the ligature, with different degrees of bilioperitoneum and/or biloma. In all cases, a Roux-en-Y hepatojejunostomy was performed. Bile duct ligature produces dilation in a very small number of patients (less than 10%) and usually produces necrosis of the blinded stump with subsequent bile leakage. Placement of a subhepatic drain and transference of the patient to a qualified center for reconstruction is the best approach if the primary surgeon is not able to do the repair.
Ojima, Jun
2017-03-28
In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.
Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw
2018-04-10
Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.
Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweet, M. L.; Francisco, A.; Roberts, S. G.
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
Fukai, Manami; Kamisawa, Terumi; Horiguchi, Shin-Ichirou; Hishima, Tsunekazu; Kuruma, Sawako; Chiba, Kazuro; Koizumi, Satomi; Tabata, Taku; Nagao, Sayaka; Kikuyama, Masataka; Honda, Goro; Kurata, Masanao
2017-06-01
We present a resected case of annular pancreas in which Wirsung's duct encircled the duodenum and continued directly to the main pancreatic duct in the body and tail. Furthermore, Wirsung's duct coursed along the right side of the lower bile duct near the major duodenal papilla. Histologically, the islets of Langerhans in the annular pancreas were irregular in shape and were characterized by a striking abundance of pancreatic polypeptide (PP)-positive cells. The PP-rich area that encircled the duodenum was fused with the PP-poor area in the head of the pancreas. The following embryological hypothesis is proposed. The tip of the ventral pancreatic anlage adhered to the duodenal wall and stretched to form a ring during clockwise rotation. The rotation was incomplete, and the pancreatic duct did not cross over the lower bile duct. Since there was adequate ventral anlage in the lower part of the head of the pancreas, fusion between the ducts of the ventral and dorsal anlagen did not occur. The tip of the ventral anlage overgrew and adhered to the dorsal anlage, and the annular duct fused with the main duct of the dorsal anlage.
Reciprocity principle in duct acoustics
NASA Technical Reports Server (NTRS)
Cho, Y.-C.
1979-01-01
Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, M. N. K., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Zuradzman, M. Razlan, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Hazry, D., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my
2014-12-04
This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors andmore » the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.« less
NASA Astrophysics Data System (ADS)
Nagib, Hassan; Vidal, Alvaro; Vinuesa, Ricardo; Schlatter, Philipp
2017-11-01
Direct numerical simulations of fully-developed turbulent flow through various straight ducts with sharp or rounded corners of various radii were performed to study influence of corner geometry on secondary flows. Unexpectedly, increased rounding of corners in rectangular ducts does not lead to monotonic trend towards pipe case. Instead, secondary vortices relocate close to regions of wall-curvature change. This behavior is connected to inhomogeneous interaction between near-wall bursting events, which are further characterized in this work with definition of their local preferential direction, and vorticity fluxes. Although these motions are relatively weak compared to streamwise velocity their effect on turbulence statistics and shear-stress distribution is very important and has not been sufficiently documented or fully understood. Flow through spanwise-periodic channels, with sinusoidal function to define the geometry of wall, yw = +/- h + A cos(ωz) , was also studied as model flow that is parametrically changed using A and ω, while taking advantage of many resulting symmetries. Consequences on experimental facilities and comparisons between experiments and various numerical and theoretical models are discussed revealing the uniqueness of pipe flow.
NASA Astrophysics Data System (ADS)
Othman, M. N. K.; Zuradzman, M. Razlan; Hazry, D.; Khairunizam, Wan; Shahriman, A. B.; Yaacob, S.; Ahmed, S. Faiz; Hussain, Abadalsalam T.
2014-12-01
This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.
Flow Simulation of Modified Duct System Wind Turbines Installed on Vehicle
NASA Astrophysics Data System (ADS)
Rosly, N.; Mohd, S.; Zulkafli, M. F.; Ghafir, M. F. Abdul; Shamsudin, S. S.; Muhammad, W. N. A. Wan
2017-10-01
This study investigates the characteristics of airflow with a flow guide installed and output power generated by wind turbine system being installed on a pickup truck. The wind turbine models were modelled by using SolidWorks 2015 software. In order to investigate the characteristic of air flow inside the wind turbine system, a computer simulation (by using ANSYS Fluent software) is used. There were few models being designed and simulated, one without the rotor installed and another two with rotor installed in the wind turbine system. Three velocities being used for the simulation which are 16.7 m/s (60 km/h), 25 m/s (90 km/h) and 33.33 m/s (120 km/h). The study proved that the flow guide did give an impact to the output power produced by the wind turbine system. The predicted result from this study is the velocity of the air inside the ducting system of the present model is better that reference model. Besides, the flow guide implemented in the ducting system gives a big impact on the characteristics of the air flow.
Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct
NASA Technical Reports Server (NTRS)
Kandula, Max
2011-01-01
The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.
Investigation in the 7-by-10 Foot Wind Tunnel of Ducts for Cooling Radiators within an Airplane Wing
NASA Technical Reports Server (NTRS)
Harris, Thomas A; Recant, Isidore G
1942-01-01
Report presents the results of an investigation made in the NACA 7 by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional-flow setup with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included.
Study of heat exchange in cooling systems of heat-stressed structures
NASA Astrophysics Data System (ADS)
Vikulin, A. V.; Yaroslavtsev, N. L.; Zemlyanaya, V. A.
2017-01-01
Increasing working parameters of the cycle of gas-turbine engines, complicating design of gas-turbine plants, as well as growing aerodynamic, thermal, static, and dynamic loads, necessitate the development of promising cooling systems for heat-stressed structures. This work is devoted to an experimental study of heat exchange in ducts equipped with systems of inclined and cross walls (fins). It has been found that an increase in the Reynolds number Re from 3000 to 20000 leads to a decrease in the heat exchange, which is characterized by the relative Nusselt number overline{Nu}, by 19-30% at the angle of inclination of the walls φ = 0, 40°, 50°, and 90° if the length of the walls x w is comparable to the spacing b s and by 12-15% at φ = 30° and 90° if x w ≫ b s. If cross walls are used in cooling ducts, the length of the walls x w plays the governing role; an increase in this characteristic from 1.22 × 10-3 to 3.14 × 10-3 m leads to an increase in the intensity of heat exchange by 30-40% and to a decrease in the capacity of the entire system of the walls. It has been shown that, on surfaces with wavy fins, the intensity of heat exchange is closest to that determined in the models under study. For example, values of the Colborne criterion StPr2/3 for ducts equipped with wavy fins and for the models under study differ only slightly (by 2-20% depending on the value of the angle φ). However, the difference for surfaces with short plate fins and ducts equipped with inclined walls is high (30-40%). This is due to the design features of these surfaces and to the severe effect of the inlet portion on heat exchange, since the surfaces are characterized by a higher ratio of the duct length to the hydraulic diameter L/d h at small fin thicknesses ((0.1-0.15) × 10-3 m). The experimental results can be used in developing designs of nozzle and rotor blades of high-temperature gas turbines in gas-turbine engines and plants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Kochkin, M. Sweet
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-02-01
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles
NASA Astrophysics Data System (ADS)
Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.
2012-03-01
Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).
[Expression of calponin and P63 in human submandibular glands].
Lu, Yu-he; Gao, Yan
2007-02-01
To observe the expression of new myoepithelial cell markers calponin and P63 in human submandibular glands. Calponin and P63 antigen in routinely processed human submandibular gland tissues were immunohistochemically demonstrated by monoclonal antibodies to calponin and P63. Calponin expressed around all acinus and intercalated ducts as linear or punctuate pattern. Positive staining was also noted in peripheral area of some thin striated ducts that connect to intercalated ducts. Subulate or trigonal calponin expression was sometimes seen between the duct dells of striated ducts. P63 expressed mainly in the nucleus of the basal cells of excretory duct. Calponin is an ideal gland. P63 labels mainly the basal cells of excretory duct. marker for myoepithelial cells of human submandibular
Total rupture of hydatid cyst of liver in to common bile duct: a case report.
Robleh, Hassan; Yassine, Fahmi; Driss, Khaiz; Khalid, Elhattabi; Fatima-Zahra, Bensardi; Saad, Berrada; Rachid, Lefriyekh; Abdalaziz, Fadil; Najib, Zerouali Ouariti
2014-01-01
Rupture of hydatid liver cyst into biliary tree is frequent complications that involve the common hepatic duct, lobar biliary branches, the small intrahepatic bile ducts,but rarely rupture into common bile duct. The rupture of hydatid cyst is serious life threating event. The authors are reporting a case of total rupture of hydatid cyst of liver into common bile duct. A 50-year-old male patient who presented with acute cholangitis was diagnosed as a case of totally rupture of hydatid cyst on Abdominal CT Scan. Rupture of hydatid cyst of liver into common bile duct and the gallbladder was confirmed on surgery. Treated by cholecystectomy and T-tube drainage of Common bile duct.
Gál, Adrián Róbert; Kalmár-Nagy, Károly; Fincsur, András; Horváth, Örs Péter; Vereczkei, András
2018-03-01
The authors present a case of a 67-year-old male patient, who previously had been diagnosed with a malignant liver tumor localized in segment II. He underwent bisegmentectomy (II and III) and partial IV segmentectomy. After the primary surgery jaundice developed, the level of bilirubin increased and after several imaging modalities reoperation was indicated. During the surgery a rare bile duct anatomy variant was found. The right hepatic duct joined the left duct in the parenchyma of the left lobe, and was ligated at the resection. As the liver hilum was not explored, the absence of the right duct was not discovered. Reconstruction of the biliary system was accomplished by a Roux-en-Y loop.
Preliminary Investigation of Curved Liner Sample in the NASA LaRC Curved Duct Test Rig
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.
2007-01-01
This viewgraph presentation reviews the preliminary investigation of the curved liner sample in the NASA LaRC Curved Duct Test Rig (CDTR). It reviews the purpose of the Curved Duct Test Rig. Its purpose is to develop capability to investigate acoustic and aerodynamic properties in ducts. It has several features to accomplish that purpose: (1) Large scale (2) Flow rate to M = 0.275 (3) Higher order mode control (4) Curved flow path (5) Adaptable test section (6) Flexible test configurations. The liner has minimal effect on turbulence or boundary layer growth in duct. The curved duct sample attenuation is affected by mode scattering. In conclusion, the CDTR is valid tool for aerodynamic and acoustic evaluation of duct treatment
Post-Tensioning Duct Air Pressure Testing Effects on Web Cracking
DOT National Transportation Integrated Search
2015-01-01
Nevada Department of Transportation (NDOT) post-tensioned concrete bridges have experienced web cracking near the post-tensioning ducts during the construction process. The ducts were air pressure tested to ensure the duct can successfully be grouted...
Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh
2016-01-01
Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones. PMID:27047698
Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun
2013-01-01
Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new “papillary-like main pancreatic duct invaginated” techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the “papillary-like main pancreatic duct invaginated” group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the “papillary-like main pancreatic duct invaginated” group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas. PMID:23797701
Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh
2016-01-01
Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones.
Pure laparoscopic radical resection for type IIIa hilar cholangiocarcinoma.
Zhang, Cheng-Wu; Liu, Jie; Hong, De-Fei; Wang, Zhi-Fei; Hu, Zhi-Ming; Huang, Dong-Shen; Shang, Min-Jie; Yao, Wei-Feng
2018-03-01
Pure laparoscopic radical resection of hilar cholangiocarcinoma is still a challenging procedure, in which laparoscopic lymphadenectomy, hemihepatectomy with caudate lobectomy, and hepaticojejunostomy were included [1-4]. Relative report is rare in the world up to now. Hilar cholangiocarcinoma has a poor prognosis, especially when it occurs with lymph node metastasis or vessel invasion [5, 6]. We recently had a patient who underwent a pure laparoscopic extended right hepatectomy and lymph node dissection and hepaticojejunostomy for a type IIIa hilar cholangiocarcinoma. The tumor was 20 × 15 × 12 mm in diameter and located in the right bile duct and common hepatic duct. Radiological examination showed that hepatic artery and portal vein was not invaded. After the division and mutilation of the right hepatic artery and the right portal vein, short hepatic veins were divided and cut off with clip and ultrasound knife from the anterior face of the vena cava. Mobilization was performed after the devascularization of the right liver, followed by the transection of liver parenchymal with CUSA and ultrasound knife. Finally, left hepatic bile duct jejunum Roux-en-Y reconstruction was performed. This patient underwent successfully with a totally laparoscopic procedure. An extended right hepatectomy (right hemihepatectomy combined with caudate lobectomy) and complete lymph node dissection and hepaticojejunostomy were performed in this operation. The operation time was nearly 590 min, and the intraoperative blood loss was about 300 ml. No obvious complication was observed and the postoperative hospital stay was 11 days. The final diagnosis of the hilar cholangiocarcinoma with no lymph node metastasis was pT2bN0M0 stage II (American Joint Committee on Cancer, AJCC). Pure laparoscopic resection for hilar cholangiocarcinoma was proved safe and feasible, which enabled the patient to recover early and have an opportunity to receive chemotherapy as soon as possible. We present a video of the described procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullins, JP; Deufel, CL
Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives thatmore » it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.« less
Mozafari, Sayedeh Zahra; Shiravi, Abdolhossein; Todehdehghan, Fatemeh
2012-01-01
Reproductive parameters evaluation is considered as helpful tool for gene bank formation in ecological and economically important animals species. Gloydius halys caucasicus is venomous, viviparous pit viper of northwest of Iran. In this research, the spermatic reproductive parameters of this taxon were studied. Twenty six male snakes were collected from Takht-e-Soleiman region between September and October, 2010. Findings revealed that male snakes with body length of 45.07 ± 2.83 cm and body weight of 51.50 ± 10.42 g, and right and left gonads volume of 0.12 ± 0.03 mL and 0.06 ± 0.01 mL are mature ones and sperms concentration in first, middle and final regions of vas deferens duct were, 22.30 ± 19.34 ×10(6) mL(-1), 30.34 ± 11.55 ×10(6) mL(-1), and 37.65 ± 16.46×10(6) mL(-1), respectively. The sperms motility at three regions of duct were 60.53%, 62.07%, and 60.00% and percentage of immotile sperms in these regions were 39.46%, 37.92%, and 39.84%, respectively. Percentage of morphologically normal sperms was 69.23 ± 10.57% and abnormal sperms was 30.76 ± 10.57%; including 12.69 ± 5.25% spiral tailed, 7.33 ± 4.37% coiled tailed and 4.16 ± 2.51% folded tailed sperms. Percentage of live sperms in the first, middle and final regions of duct were 55.76 ± 10.77%, 58.84 ± 12.77%, and 57.69 ± 9.91%, respectively and percentage of dead sperm in these regions were 44.23 ± 10.77%, 41.15 ± 12.77%, and 42.30 ± 9.91%, respectively. Results suggested, mature sperms with acceptable reproductive quality could be collected from Gloydius halys caucasicus snake of Iran between September and October.
Koga, Hiroyuki; Okawada, Manabu; Doi, Takashi; Miyano, Go; Lane, Geoffrey J; Yamataka, Atsuyuki
2015-10-01
During surgery for choledochal cyst (CC), any intrapancreatic CC (IPCC) must also be excised to prevent postoperative pancreatitis and stone formation. We report our technique for laparoscopic total IPCC excision (n = 16; mean age 6.0 years). We insert a fine ureteroscope with a light source into the opened CC through an extra 3.9-mm trocar placed in the epigastrium through a minute incision to identify the pancreatic duct orifice. By pulling the end of the ureteroscope emerging from the trocar gently to withdraw the tip from the pancreatic duct to where distal dissection was ceased under laparoscopic view, the IPCC can be measured. If longer than 5 mm, the distal CC is dissected further caudally until it is less than 5 mm. For accuracy, the distal CC is elevated with a suture that is exteriorized and clamped to provide constant traction. The IPCC was able to be measured in 11/16 (68 %). Initial lengths measured were 3-10 mm (5.2 ± 2.7 mm). Final IPCC were all 5 mm or less. Surgery was uncomplicated without any pancreatic duct injury and postoperative recovery was unremarkable. Follow-up MRI at 32 months showed no IPCC in any case. Measuring the IPCC enables total CC excision, thus reducing the potential for postoperative complications.
Recent advances in cardiac catheterization for congenital heart disease
Kang, Sok-Leng; Benson, Lee
2018-01-01
The field of pediatric and adult congenital cardiac catheterization has evolved rapidly in recent years. This review will focus on some of the newer endovascular technological and management strategies now being applied in the pediatric interventional laboratory. Emerging imaging techniques such as three-dimensional (3D) rotational angiography, multi-modal image fusion, 3D printing, and holographic imaging have the potential to enhance our understanding of complex congenital heart lesions for diagnostic or interventional purposes. While fluoroscopy and standard angiography remain procedural cornerstones, improved equipment design has allowed for effective radiation exposure reduction strategies. Innovations in device design and implantation techniques have enabled the application of percutaneous therapies in a wider range of patients, especially those with prohibitive surgical risk. For example, there is growing experience in transcatheter duct occlusion in symptomatic low-weight or premature infants and stent implantation into the right ventricular outflow tract or arterial duct in cyanotic neonates with duct-dependent pulmonary circulations. The application of percutaneous pulmonary valve implantation has been extended to a broader patient population with dysfunctional ‘native’ right ventricular outflow tracts and has spurred the development of novel techniques and devices to solve associated anatomic challenges. Finally, hybrid strategies, combining cardiosurgical and interventional approaches, have enhanced our capabilities to provide care for those with the most complex of lesions while optimizing efficacy and safety. PMID:29636905
Two-stage, low noise advanced technology fan. 5: Acoustic final report
NASA Technical Reports Server (NTRS)
Sofrin, T. G.; Riloff, N., Jr.
1975-01-01
The NASA Q2S(quiet two-stage) fan is a 0.836m (32.9 in.) diameter model of the STF 433 engine fan, selected in a 1972 study for an Advanced Technology Transport (ATT) airplane. Noise-control features include: low tip speed, moderate stage pressure rise, large blade-vane spacings, no inlet guide vanes, and optimum blade and vane numbers. Tests were run on the baseline Q2S fan with standard inlet and discharge ducts. Further tests were made of a translating centerbody sonic inlet device and treated discharge ducts. Results were scaled to JT8D and JT3D engine fan size for comparison with current two-stage fans, and were also scaled to STF 433 fan size to compare calculated ATT flyover noise with FAR 36 limits. Baseline Q2S results scaled to JT8D and JT3D engine fan sizes showed substantial noise reductions. Calculated unsuppressed baseline ATT flyovers averaged about 2.5 EPNdB below FAR 36 limits. Using measured sonic inlet results, scaled baseline Q2S fan results, and calculated attenuations for a 1975 technology duct liner, projected flyover noise calculations for the ATT averaged about FAR 36 limits minus 10 EPNdB. Advances in suppression technology required to meet the 1985 goal of FAR 36 limits minus 20 EPNdB are discussed.
2013-12-01
depression, tropical storm , hurricane, extratropical cyclone, subtropical depression, subtropical storm , a low of no category, tropical wave, disturbance or...surface-based ducts, and elevated ducts. We further separate the duct occurrence based on the location relative to their respective storms . Based...on the number of soundings in different types of tropical disturbances, we chose to further analyze duct conditions in hurricanes and tropical storms
Mucocele of the cystic duct remnant after orthotopic liver transplant: a problem revisited.
Chatterjee, Suvadip; Das, Debasish; Hudson, Mark; Bassendine, Margaret Fiona; Scott, John; Oppong, Kofi Ernest; Sen, Gourab; French, Jeremy J
2011-06-01
Mucocele of the cystic duct remnant is an uncommon hepatobiliary complication of a liver transplant. Current practice usually involves either excising the cystic duct, or incorporating the distal end of the transected cystic duct into the suture line of the biliary anastomosis to ensure drainage. We report a patient who developed cystic duct remnant mucocele after the latter approach was adopted. We believe that this is likely related to delayed anastomotic stricturing, which prevented draining from the remnant cystic duct. We also discuss the incidence, pathology, investigations, and treatment of this condition.
Beach, R.J.; Benett, W.J.
1994-04-26
A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.
Simple resection of the lesion bile duct branch for treatment of regional hepatic bile duct stones
Enliang, Li; Rongshou, Wu; Shidai, Shi; Jingling, Zhang; Qian, Feng; Wenjun, Liao; Linquan, Wu
2017-01-01
Abstract To evaluate the effectiveness and safety of simple resections of bile duct branch lesions for the treatment of regional hepatic bile duct stones. A retrospective analysis of the clinical data from patients in our hospital from November 2008 to November 2015, who only underwent a simple resection of the lesion bile duct branch. The patients’ clinical characteristics, surgical features, postoperative complications, stone clear rate, residual stone rate, and recurrence stone rate were analyzed. This study of 32 patients included 13 males and 19 females with intrahepatic bile duct stones confined to the right hepatic bile duct branch. The intraoperative blood loss, operation time, and postoperative hospital stay were 478.0 ± 86.5, 210.7 ± 6.6, and 10.8 ± 3.5, respectively. Postoperative complications occurred in 6 patients (18.8%), all of whom recovered with conservative management. There were no deaths during hospitalization. The intraoperative stone clearance rate was 95.8%. Three patients had a recurrence of stones at a mean of 22 months of follow-up (range, 4–36 months). Simple resection of bile duct branch lesions is safe and feasible for patients who have regional hepatic bile duct stones limited to the right hepatic bile duct branches. PMID:28682899
Reference values of MRI measurements of the common bile duct and pancreatic duct in children.
Gwal, Kriti; Bedoya, Maria A; Patel, Neal; Rambhatla, Siri J; Darge, Kassa; Sreedharan, Ram R; Anupindi, Sudha A
2015-07-01
Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial measurement was 2.0 mm; the mean coronal measurement of the pancreatic duct was 0.9 mm and the axial measurement was 0.8 mm. Our study provides normative measurements for the common bile duct and pancreatic duct for children up to age 10 years. The upper limits of the CBD and pancreatic duct increase with age, and the values range 1.1-4.0 mm for the CBD and 0.6-1.9 mm for the pancreatic duct.
Holographic flow visualization in rotating turbomachinery
NASA Astrophysics Data System (ADS)
Parker, R. J.; Reeves, M.
1990-11-01
Holographic flow visualization has found many applications in rotating turbomachinery. Applications in the design of aeroengine fans, automotive turbochargers, turbines, helicopter rotors, and advanced propfans are discussed. Work in ducted rotating flows and rotating free aerofoils is brought together and new developments in each field are revealed.
A Plug-and-Play Duct System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beach, Robert; Dickson, Bruce; Grisolia, Anthony
This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less
Choi, Jin Woo; Kim, Kyoung Won; Kim, Ah Young; Kim, Pyo Nyun; Ha, Hyun Kwon; Lee, Moon-Gyu
2003-01-01
Objective To describe the anatomical variation occurring in intrahepatic bile ducts (IHDs) in terms of their branching patterns, and to determine the frequency of each variation. Materials and Methods The study group consisted of 300 consecutive donors for liver transplantation who underwent intraoperative cholangiography. Anatomical variation in IHDs was classified according to the branching pattern of the right anterior and right posterior segmental duct (RASD and RPSD, respectively), and the presence or absence of the first-order branch of the left hepatic duct (LHD), and of an accessory hepatic duct. Results The anatomy of the intrahepatic bile ducts was typical in 63% of cases (n=188), showed triple confluence in 10% (n=29), anomalous drainage of the RPSD into the LHD in 11% (n=34), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 6% (n=19), anomalous drainage of the RPSD into the cystic duct in 2% (n=6), drainage of the right hepatic duct (RHD) into the cystic duct (n=1), the presence of an accessory duct leading to the CHD or RHD in 5% (n=16), individual drainage of the LHD into the RHD or CHD in 1% (n=4), and unclassified or complex variation in 1% (n=3). Conclusion The branching pattern of IHDs was atypical in 37% of cases. The two most common variations were drainage of the RPSD into the LHD (11%) and triple confluence of the RASD, RPSD and LHD (10%). PMID:12845303
Anatomy of the lactating human breast redefined with ultrasound imaging
Ramsay, DT; Kent, JC; Hartmann, RA; Hartman, PE
2005-01-01
The aim of this study was to use ultrasound imaging to re-investigate the anatomy of the lactating breast. The breasts of 21 fully lactating women (1–6 months post partum) were scanned using an ACUSON XP10 (5–10 MHz linear array probe). The number of main ducts was measured, ductal morphology was determined, and the distribution of glandular and adipose tissue was recorded. Milk ducts appeared as hypoechoic tubular structures with echogenic walls that often contained echoes. Ducts were easily compressed and did not display typical sinuses. All ducts branched within the areolar radius, the first branch occurring 8.0 ± 5.5 mm from the nipple. Duct diameter was 1.9 ± 0.6 mm, 2.0 ± 90.7 mm and the number of main ducts was 9.6 ± 2.9, 9.2 ± 2.9, for left and right breast, respectively. Milk ducts are superficial, easily compressible and echoes within the duct represent fat globules in breastmilk. The low number and size of the ducts, the rapid branching under the areola and the absence of sinuses suggest that ducts transport breastmilk, rather than store it. The distribution of adipose and glandular tissue showed wide variation between women but not between breasts within women. The proportion of glandular and fat tissue and the number and size of ducts were not related to milk production. This study highlights inconsistencies in anatomical literature that impact on breast physiology, breastfeeding management and ultrasound assessment. PMID:15960763
NASA Astrophysics Data System (ADS)
Yang, Cheng; Fang, Yi; Zhao, Chao; Zhang, Xin
2018-06-01
A duct acoustics model is an essential component of an impedance eduction technique and its computation cost determines the impedance measurement efficiency. In this paper, a model is developed for the sound propagation through a lined duct carrying a uniform mean flow. In contrast to many existing models, the interface between the liner and the duct field is defined with a modified Ingard-Myers boundary condition that takes account of the effect of the boundary layer above the liner. A mode-matching method is used to couple the unlined and lined duct segments for the model development. For the lined duct segment, the eigenvalue problem resulted from the modified boundary condition is solved by an integration scheme which, on the one hand, allows the lined duct modes to be computed in an efficient manner, and on the other hand, orders the modes automatically. The duct acoustics model developed from the solved lined duct modes is shown to converge more rapidly than the one developed from the rigid-walled duct modes. Validation against the experiment data in the literature shows that the proposed model is able to predict more accurately the liner performance measured by the two-source method. This, however, cannot be made by a duct acoustics model associated with the conventional Ingard-Myers boundary condition. The proposed model has the potential to be integrated into an impedance eduction technique for more reliable liner measurement.
Reconstruction of Bile Duct Injury and Defect with the Round Ligament.
Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier
2017-09-01
Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.
Nishi, Takeshi; Sato, Yoshitoshi; Hanaoka, Takuya; Takahashi, Takuya; Miura, Hiroshi; Takubo, Kenji
2018-01-01
Double cancers of the biliary tract system are rare. Most of these cancers are synchronous double cancers of the gall bladder and bile duct, associated with pancreaticobiliary maljunction (PBM). Synchronous double cancers of the extrahepatic bile duct without PBM are especially rare, and only 4 cases have been reported. A 78-year-old woman was admitted to our hospital for examination of hyperbilirubinemia and liver dysfunction. Contrast-enhanced abdominal computed tomography, Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography revealed 2 stenotic regions in the common bile duct: at its junction with the cystic duct and in the distal bile duct. No findings suggested PBM, such as a markedly long common channel. The diagnosis based on endoscopic brush cytology from both stricture portions was adenocarcinoma. The patient had a pylorus-preserving pancreaticoduodenectomy with regional lymph node resection. Macroscopically, there were 2 stenotic regions at the cystic duct junction and in the distal bile duct. Microscopically, the tumor at the junction of the cystic duct was a well-to-moderately differentiated adenocarcinoma. On the other hand, the tumor of the distal bile duct was a poorly differentiated adenocarcinoma. There was no evidence of communication between these 2 cancers. Double cancers of the extrahepatic bile duct without PBM are very rare. Therefore, an accurate diagnosis prior to surgery is necessary. Furthermore, this rare condition seems to be associated with a poor prognosis. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S
2016-05-01
In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.
A Plug-and-Play Duct System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beach, R.; Dickson, B.; Grisolia, A.
2017-07-01
This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less
Mockup Small-Diameter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke and A. Rudd
2016-05-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Anatomic variations in intrahepatic bile ducts in a north Indian population.
Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas
2008-07-01
In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).
NASA Technical Reports Server (NTRS)
George-Falvy, Dez
1992-01-01
Circumferential design combines compactness and efficiency. In remotely controlled valve, flow in tributary duct along circumference of primary duct merged with flow in primary duct. Flow in tributary duct regulated by variable throat nuzzle driven by worm gear. Design leak-proof, and most components easily fabricated on lathe.
NASA Astrophysics Data System (ADS)
Frolov, Vladimir; Rauch, Jean-Louis; Parrot, Michel; Rapoport, Victor; Shorokhova, Elena
In the report we consider features of plasma density and electro-magnetic field perturbations induced in the Earth’s outer ionosphere by modification of F _{2} region by O-mode powerful HF radio waves radiated by the SURA heating facility. Experiments presented were carried out in 2005 - 2010. Plasma density perturbations were detected at altitudes of about of 700 km by instruments onboard the French DEMETER satellite when it intersected the disturbed magnetic flux tube. The formation of artificial HF-induced plasma density ducts in the outer ionosphere is a central discovery, which was made during the SURA-DEMETER experiments [1,2]. Analysis of experimental data available makes it possible to formulate ducts features and point out the conditions under which the formation of such ducts takes place. 1. Under night conditions ducts are characterized by the increased plasma density in the range from 20% to 80% relatively to its background value. As this takes place, the excess in the plasma ion component is due to O (+) ions dominating at altitudes of about 700 km, whereas the densities of lower mass H (+) and He ({+) } ions typically decrease by a percentage amount that is much more the relative increase in the density of O (+) ions. The duct formation was never observed under daytime conditions. According to [3] the HF-induced ducts were observed by ionosphere pumping in morning and evening hours but in these cases their intensity was no more than a few percentages. 2. The size of the ducts along the satellite orbits is of about 80 - 100 km. It is a reason why such ducts can be observed only if the minimal distance between the satellite and the center of the heated flux tube is less than 50 km. 3. The formation of ducts is observed only if the effective radiated power is more than 40 MW. For the SURA facility, to heat the ionosphere at higher efficiency due to the “magnetic-zenith effect”, the HF beam is often inclined by 12 - 16(°) southward. 4. The pump wave frequency should be no less than 0.5 - 0.7 MHz below the F _{2} layer critical frequency f _{0F2}. In the opposed case the penetration of the radiated power behind the F _{2} ionospheric layer can take place [4]. 5. Strong variations of the electron temperature are observed inside the ducts, at the same time the ion temperature is unchanged. 6. A feature of the ducts is the presence of strong electro-magnetic field fluctuations in a frequency range from a few Hz to tens of kHz [1,5]. 7. It was revealed that the formation of the ducts in the outer ionosphere can stimulate the precipitation of energetic electrons with E ≥ 100 keV from the Earth’s radiation belts [6]. The work was supported by RFBR grants (## 12-05-00312, 13-02-12074, 13-02-12241) and by the scientific program “Geophysics”. References: 1. Rapoport V.O., V.L. Frolov, G.P. Komrakov, et al. // Radiophysics and Quantum Electronics, 2007. Vol. 50(8), p. 645. 2. Frolov V.L., V.O. Rapoport, G.P. Komrakov, et. al. // JETP Letters, 2008. Vol. 88, No. 12, p. 790. 3. Frolov V.L., I.A. Bolotin, V.O. Rapoport, et. al. // XXIV All-Russian conference “Radio Wave Propagation”. Irkutsk, 2014 (submitted for publication). 4. Frolov V.L., N.A. Mityakov, E.A. Shorokhova, M. Parrot. // Radiophysics and Quantum Electronics, 2013. Vol. 56(6), p. 325. 5. Rapoport V.O., V.L. Frolov, S.V. Polyakov, et al. // J. Geophys. Res., 2010. Vol. 115, A10322, doi:10.1029/2010JA015484. 6. Markov G.A., A.S. Belov, V.L. Frolov, et al. // JETPh, 2010. Vol. 138, No. 6(12), p. 1037.
NASA Technical Reports Server (NTRS)
Boger, David A.; Govindan, T. R.; McDonald, Henry
1997-01-01
Previous work at NASA LeRC has shown that flow distortions in aircraft engine inlet ducts can be significantly reduced by mounting vortex generators, or small wing sections, on the inside surface of the engine inlet. The placement of the vortex generators is an important factor in obtaining the optimal effect over a wide operating envelope. In this regard, the only alternative to a long and expensive test program which would search out this optimal configuration is a good prediction procedure which could narrow the field of search. Such a procedure has been developed in collaboration with NASA LeRC, and results obtained by NASA personnel indicate that it shows considerable promise for predicting the viscous turbulent flow in engine inlet ducts in the presence of vortex generators. The prediction tool is a computer code which numerically solves the reduced Navier-Stokes equations and so is commonly referred to as RNS3D. Obvious deficiencies in RNS3D have been addressed in previous work. Primarily, it is known that the predictions of the mean velocity field of a turbulent boundary layer flow approaching separation are not in good agreement with data. It was suggested that the use of an algebraic mixing-length turbulence model in RNS3D is at least partly to blame for this. Additionally, the current turbulence model includes an assumption of isotropy which will ultimately fail to capture turbulence-driven secondary flow known to exist in noncircular ducts.
Cholestasis‐induced adaptive remodeling of interlobular bile ducts
Damle‐Vartak, Amruta; Richter, Beate; Dirsch, Olaf; Dahmen, Uta; Hammad, Seddik
2016-01-01
Cholestasis is a common complication in liver diseases that triggers a proliferative response of the biliary tree. Bile duct ligation (BDL) is a frequently used model of cholestasis in rodents. To determine which changes occur in the three‐dimensional (3D) architecture of the interlobular bile duct during cholestasis, we used 3D confocal imaging, surface reconstructions, and automated image quantification covering a period up to 28 days after BDL. We show a highly reproducible sequence of interlobular duct remodeling, where cholangiocyte proliferation initially causes corrugation of the luminal duct surface, leading to an approximately five‐fold increase in surface area. This is analogous to the function of villi in the intestine or sulci in the brain, where an expansion of area is achieved within a restricted volume. The increase in surface area is further enhanced by duct branching, branch elongation, and loop formation through self‐joining, whereby an initially relatively sparse mesh surrounding the portal vein becomes five‐fold denser through elongation, corrugation, and ramification. The number of connections between the bile duct and the lobular bile canalicular network by the canals of Hering decreases proportionally to the increase in bile duct length, suggesting that no novel connections are established. The diameter of the interlobular bile duct remains constant after BDL, a response that is qualitatively distinct from that of large bile ducts, which tend to enlarge their diameters. Therefore, volume enhancement is only due to net elongation of the ducts. Because curvature and tortuosity of the bile duct are unaltered, this enlargement of the biliary tree is caused by branching and not by convolution. Conclusion: BDL causes adaptive remodeling that aims at optimizing the intraluminal surface area by way of corrugation and branching. (Hepatology 2016;63:951–964) PMID:26610202
Lawlor, Shawn P.; Roberts, II, William Byron
2016-03-08
A gas turbine engine with a compressor rotor having compressor impulse blades that delivers gas at supersonic conditions to a stator. The stator includes a one or more aerodynamic ducts that each have a converging portion and a diverging portion for deceleration of the selected gas to subsonic conditions and to deliver a high pressure oxidant containing gas to flameholders. The flameholders may be provided as trapped vortex combustors, for combustion of a fuel to produce hot pressurized combustion gases. The hot pressurized combustion gases are choked before passing out of an aerodynamic duct to a turbine. Work is recovered in a turbine by expanding the combustion gases through impulse blades. By balancing the axial loading on compressor impulse blades and turbine impulse blades, asymmetrical thrust is minimized or avoided.
[Calculi formation and biliary hydrodynamics].
Zou, S Q
1990-09-01
In this study, 167 white rabbits were divided into 5 groups to observe the effects of biliary stricture and infection on the formation of bile duct stones and the pathophysiological changes of the biliary tract. It was found that there was a gradient of static hydraulic pressure along biliary tract and the pressure was directly proportional to hepatic blood flow. In the rabbits with bile duct stone formation, the activity of SDH, ATP ase and glycogen (PAS) in the mucosa of biliary tract was low and that of LDH was high. In the biliary tract wall damaged by infection and choledocholithiasis, a frame work consisting of polysaccharide protein, mucin, and mucoid polymer was observed and the authors considered it as one of causing factors in the formation of the stones.
Rapid detonation initiation by sparks in a short duct: a numerical study
NASA Astrophysics Data System (ADS)
Hu, Z. M.; Dou, H. S.; Khoo, B. C.
2010-06-01
Rapid onset of detonation can efficiently increase the working frequency of a pulse detonation engine (PDE). In the present study, computations of detonation initiation in a duct are conducted to investigate the mechanisms of detonation initiation. The governing equations are the Euler equations and the chemical kinetic model consists of 19 elementary reactions and nine species. Different techniques of initiation have been studied for the purpose of accelerating detonation onset with a relatively weak ignition energy. It is found that detonation ignition induced by means of multiple sparks is applicable to auto-ignition for a PDE. The interaction among shock waves, flame fronts and the strip of pre-compressed fresh (unburned) mixture plays an important role in rapid onset of detonation.
Effects of partial portal vein arterialization on the hilar bile duct in a rat model.
Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng
2011-10-01
Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (P<0.01). No apoptotic hilar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (P<0.01). No statistically significant differences in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and albumin were found in the 3 groups. The gamma-glutamyltransferase value was higher in group B than in groups A and C (P<0.01). The hepatic tissues of groups A and C showed no significant abnormality. Chronic inflammatory changes in the hilar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.
Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.
Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin
2013-06-01
Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot system, complicated billiary reconstruction can be performed (http://links.lww.com/SLE/A74).
A novel technique of percutaneous stone extraction in choledocholithiasis after cholecystostomy.
Lim, Kyoung Hoon; Kim, Yong Joo
2013-05-01
To evaluate the technical feasibility and clinical efficacy of percutaneous common bile duct stone extraction via cystic duct after percutaneous cholecystostomy. Twenty-five consecutive patients with choledocholithiasis underwent percutaneous stone extraction under conscious sedation. The stones were extracted through the 12-Fr sheath using Wittich nitinol stone basket under fluoroscopic guidance via cystic duct after percutaneous trnas-hepatic cholecystostomy. Common bile duct stones were successfully removed in 22 of the 25 patients (88%) by this new technique. The causes of failure in three patients were bile leakage, hematoma of the gallbladder and failure of cystic duct cannulation. Cystic duct injury during this procedure did not occur and there was no post-procedure mortality. The mean period of indwelling catheter was 8.7±4.6 days and the mean duration of hospitalization was 13.4±5.9 days. Percutaneous commmon bile duct stone extraction via the cystic duct through percutaneous cholecystostomy route is effective and feasible for treating choledocholithiasis.
Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin
2013-04-21
At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.
Study of Gas Solid Flow Characteristics in Cyclone Inlet Ducts of A300Mwe CFB Boiler
NASA Astrophysics Data System (ADS)
Tang, J. Y.; Lu, X. F.; Lai, J.; Liu, H. Z.
Gas solid flow characteristics in cyclone's inlet duct of a 300MW CFB boiler were studied in a cold circulating fluidized bed (CFB) experimental setup according to a 410t/h CFB boiler with a scale of 10∶1. Tracer particles were adopted in the experiment and their motion trajectories in the two kinds of cyclone's inlet ducts were photographed by a high-speed camera. By analyzing the motion trajectories of tracer particles, acceleration performance of particle phases in the two inlet ducts was obtained. Results indicate that the acceleration performance of particles in the long inlet duct is better than that in the short inlet duct, but the pressure drop of the long inlet duct is higher. Meanwhile, under the same operating conditions, both the separation efficiency and the pressure drop of the cyclone are higher when the cyclone is connected with the long inlet duct. Figs 11, Tabs 4 and refs 10.
Cherian, Mathew Pynumootil; Nair, Balakrishnan; Thomas, Shaji; Somanathan, Thara; Sebastian, Paul
2009-10-01
We report a rare case of synchronous occurrence of thyroglossal duct cyst carcinoma and thyroid carcinoma and discuss its management in detail. A 59-year-old woman was clinically diagnosed to have a thyroglossal duct cyst and a solitary nodule. Fine-needle aspiration cytology revealed a papillary carcinoma in the thyroglossal duct cyst and a colloid in the thyroid nodule. Sistrunk's procedure along with a total thyroidectomy was performed followed by postoperative radioiodine ablation. Histopathologic examination revealed thyroglossal duct cyst carcinoma and bilateral foci of papillary carcinoma in the thyroid gland. She has remained free of disease on follow-up. Most cancers arising in thyroglossal duct cysts are of low risk, and Sistrunk's procedure is an adequate treatment for such cancers. However, for synchronously occurring cancers of the thyroglossal duct cyst and thyroid gland, or high-risk thyroglossal duct cyst cancers, more aggressive treatment comprising total thyroidectomy, Sistrunk's procedure, and radioiodine therapy is indicated. (c) 2009 Wiley Periodicals, Inc.
[Clinicopathologic features of drug-induced vanishing bile duct syndrome].
Ye, L H; Wang, C K; Zhang, H C; Liu, Z Q; Zheng, H W
2017-04-20
Vanishing bile duct syndrome (VBDS) manifests as progressive destruction and disappearance of the intrahepatic bile duct caused by various factors and cholestasis. VBDS associated with drug-induced liver injury (D-VBDS) is an important etiology of VBDS, and immune disorder or immune imbalance may be the main pathogenesis. According to its clinical symptoms, serological markers, and course of the disease, D-VBDS is classified into major form and minor form, and its clinical features are based on various pathomorphological findings. Its prognosis is associated various factors including regeneration of bile duct cells, number of bile duct injuries, level and range of bile duct injury, bile duct proliferation, and compensatory shunt of bile duct branches. This disease has various clinical outcomes; most patients have good prognosis after drug withdrawal, and some patients may experience cholestatic cirrhosis, liver failure, and even death. Due to the clinical manifestation and biochemical changes are similar to the primary biliary cholangitis (PBC) and primary sclerosing cholangitis (PSC), it need to identify by clinical physician.
Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.
2010-01-01
Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siuru, B.
1996-07-01
Large amounts of energy are wasted when heat leaks through ductwork located in uninsulated spaces. The Electric Power Research INstitute recently did a study that accurately measured these losses, then substantially reduced them by sealing the leaky ductwork. Six homes in the Pacific Northwest with significant duct leakage to the outside were selected for the study. The homes had electric resistance or heat pump, forced-air heating systems with a major portion of the supply and return ductwork in crawl spaces, attics, garages, etc. Measurements of duct leakage and heating system efficiency were done on all the homes before starting themore » duct sealing. Retrofitting included finding holes, gaps, cracks and disconnected joints in supply and return ducts as well as in plenums. When necessary, plenums were cut open for repairs. Leaks were sealed with Latex mastic and fiberglass tape. Outside ducts were covered or wrapped with insulation. Unducted returns were sealed with duct board. In some cases, leakage was corrected by merely reconnecting ducts and boots.« less
NASA Technical Reports Server (NTRS)
Hippensteele, Steven A.; Poinsatte, Philip E.
1993-01-01
In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.
Effects of finite-size particles on the turbulent flows in a square duct
NASA Astrophysics Data System (ADS)
Yu, Zhaosheng; Lin, Zhaowu; Shao, Xueming; Wang, Lian-Ping
2015-11-01
Fully resolved numerical simulations of the particle-laden turbulent flows in a square duct are performed with a direct-forcing fictitious domain method. The effects of the finite-size particles on the mean and root-mean-square (RMS) velocities are investigated at the friction Reynolds number of 150 (based on the friction velocity and half duct width) and the particle volume fractions ranging from 0.78% to 7.07%. For the neutrally buoyant case, our results show that the mean secondary flow is enhanced and its circulation center shifts closer to the center of the duct cross-section when the particles are added. The reason for the particle effect on the mean secondary flow is analyzed by examining the terms in the mean streamwise vorticity equation. The particles enhance the wall-tangential component of the RMS velocity (i.e. Reynolds normal stress) more than its wall-normal component in the near-wall region near the corners, resulting in the enhancement in the gradients of the normal stress difference, which we think is mainly responsible for the enhancement in the mean secondary flow. The particles accumulate preferentially in the near-corner region in the neutrally buoyant case. In addition, the effects of particle sedimentation are examined at different Shields numbers. The work was supported by the National Natural Science Foundation of China (11372275) and Research Fund for the Doctoral Program of Higher Education of China (20130101110035).
Design of power-plant installations pressure-loss characteristics of duct components
NASA Technical Reports Server (NTRS)
Henry, John R
1944-01-01
A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)
Transition duct with divided upstream and downstream portions
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier
2015-07-14
Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing themore » upstream portion and the downstream portion.« less
Importance of resin ducts in reducing ponderosa pine mortality from bark beetle attack.
Kane, Jeffrey M; Kolb, Thomas E
2010-11-01
The relative importance of growth and defense to tree mortality during drought and bark beetle attacks is poorly understood. We addressed this issue by comparing growth and defense characteristics between 25 pairs of ponderosa pine (Pinus ponderosa) trees that survived and trees that died from drought-associated bark beetle attacks in forests of northern Arizona, USA. The three major findings of our research were: (1) xylem resin ducts in live trees were >10% larger (diameter), >25% denser (no. of resin ducts mm(-2)), and composed >50% more area per unit ring growth than dead trees; (2) measures of defense, such as resin duct production (no. of resin ducts year(-1)) and the proportion of xylem ring area to resin ducts, not growth, were the best model parameters of ponderosa pine mortality; and (3) most correlations between annual variation in growth and resin duct characteristics were positive suggesting that conditions conducive to growth also increase resin duct production. Our results suggest that trees that survive drought and subsequent bark beetle attacks invest more carbon in resin defense than trees that die, and that carbon allocation to resin ducts is a more important determinant of tree mortality than allocation to radial growth.
Double-duct liquid metal magnetohydrodynamic engine
Haaland, Carsten M.
1995-01-01
An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.
Double-duct liquid metal magnetohydrodynamic engine
Haaland, Carsten M.
1997-01-01
An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.
Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins
2009-05-01
To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.
LeSage, G D; Glaser, S S; Marucci, L; Benedetti, A; Phinizy, J L; Rodgers, R; Caligiuri, A; Papa, E; Tretjak, Z; Jezequel, A M; Holcomb, L A; Alpini, G
1999-05-01
Bile duct damage and/or loss is limited to a range of duct sizes in cholangiopathies. We tested the hypothesis that CCl4 damages only large ducts. CCl4 or mineral oil was given to bile duct-ligated (BDL) rats, and 1, 2, and 7 days later small and large cholangiocytes were purified and evaluated for apoptosis, proliferation, and secretion. In situ, we measured apoptosis by morphometric and TUNEL analysis and the number of small and large ducts by morphometry. Two days after CCl4 administration, we found an increased number of small ducts and reduced number of large ducts. In vitro apoptosis was observed only in large cholangiocytes, and this was accompanied by loss of proliferation and secretion in large cholangiocytes and loss of choleretic effect of secretin. Small cholangiocytes de novo express the secretin receptor gene and secretin-induced cAMP response. Consistent with damage of large ducts, we detected cytochrome P-4502E1 (which CCl4 converts to its radicals) only in large cholangiocytes. CCl4 induces selective apoptosis of large ducts associated with loss of large cholangiocyte proliferation and secretion.
Sound attenuations of axial fan blade tones using flow-driven tunable resonator arrays
NASA Astrophysics Data System (ADS)
Gorny, Lee James
Flow-excited, tunable quarter-wavelength resonators can be integrated into the shrouds of ducted subsonic axial fans. This study explores their effectiveness in reducing propagations of tonal noise by means of acoustic wave cancellation. Resonators are a non-intrusive method of generating a secondary sound field near the plane of a rotor. As they can be strategically tuned to reduce radiated noise at the blade passage frequency (BPF) and its harmonics, resonators can be useful for a variety of applications to quiet existing and future turbomachinery. Experiments have demonstrated that a single quarter wave resonator is effective in reducing unidirectional plane wave propagations for long wavelength ducted applications while an array is effective for shorter wavelength or un-ducted facilities where shrouded fans are used. Testing conducted at Center for Acoustics and Vibrations (CAV) at the Pennsylvania State University the Deutsches Zentrum fur Luft und Raumfahrt (DLR) in Berlin, Germany demonstrated that resonator arrays were effective in attenuating shorter wavelength plane-wave and higher order modal propagations of blade tone noise. A chiller fan enclosure, constructed in the CAV laboratory emulated an industrial chiller in its operation. Using this facility, resonators were observed to attenuate blade tone noise from a non-ideal ducted geometry. The approaches used in this study evolved from Helmholtz resonators to conventional quarter wave tubes, to mouth tunable resonators, and finally to back-wall tunable resonators. These developments in tuning allowed for independent control of a resonator's magnitude and phase of the secondary sound field produced by the resonators. It was demonstrated that the use of two tunable resonator chambers oriented axially on either side of the blade region enables a dipole-like secondary sound field to be passively generated and bi-directional attenuations of plane wave noise to be achieved. Tonal attenuations of 28 dB were attained and BPF tones were reduced to less than 5 dB from the broadband noise floor for each case discussed above. In parallel with experimental work, analytical models were developed to effectively model and predict optimal resonator configurations for a given fan in operation. Interactions between resonators and the driving pressure field from the rotor blades are modeled using transmission line (TL) theory. Blade tone acoustic pressure is obtained using a finite element method (FEM) propagation code. By combining of these two methods, a resonator configuration that achieves optimal attenuation can be numerically obtained. The use of resonators has been shown to significantly attenuate fan noise in the conditions explored in the considered experiments. Numerical modeling has shown consistency in the response of flow driven resonators and their. These results indicate a strong potential for active control of fan noise using resonators and an approach to applying this control is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilcox, Brian; May, Doug; Howlett, Don
2013-07-01
Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and developmentmore » associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition. Maintenance of building heating, ventilation and air conditioning (HVAC) balancing was critical to ensure proper airflow and worker safety. Approximately 103 m{sup 3} of equipment and materials were recovered or generated by the project. Low level waste accounted for approximately 37.4 m{sup 3}. Where possible, ducting was free released for metal recycling. Contaminated ducts were compacted into B-1000 containers and stored in a Shielded Modular Above-Ground Storage Facility (SMAGS) on the WL site awaiting final disposition. The project is divided into three significant phases, with Phases 1 and 2 completed. Lessons learned during the execution of Phases 1 and 2 have been incorporated into the current ventilation removal. (authors)« less
NASA Astrophysics Data System (ADS)
Fei, Jianfang; Ding, Juli; Huang, Xiaogang; Cheng, Xiaoping; Hu, Xiaohua
2013-06-01
The Weather Research and Forecasting model version 3.2 (WRF v3.2) was used with the bogus data assimilation (BDA) scheme and sea spray parameterization (SSP), and experiments were conducted to assess the impacts of the BDA and SSP on prediction of the typhoon ducting process induced by Typhoon Mindule (2004). The global positioning system (GPS) dropsonde observations were used for comparison. The results show that typhoon ducts are likely to form in every direction around the typhoon center, with the main type of ducts being elevated duct. With the BDA scheme included in the model initialization, the model has a better performance in predicting the existence, distribution, and strength of typhoon ducts. This improvement is attributed to the positive effect of the BDA scheme on the typhoon's ambient boundary layer structure. Sea spray affects typhoon ducts mainly by changing the latent heat (LH) flux at the air-sea interface beyond 270 km from the typhoon center. The strength of the typhoon duct is enhanced when the boundary layer under this duct is cooled and moistened by the sea spray; otherwise, the typhoon duct is weakened. The sea spray induced changes in the air-sea sensible heat (SH) flux and LH flux are concentrated in the maximum wind speed area near the typhoon center, and the changes are significantly weakened with the increase of the radial range.
NASA Technical Reports Server (NTRS)
Mclallin, K. L.; Kofskey, M. G.; Civinskas, K. C.
1983-01-01
The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.
New Whole-House Solutions Case Study: John Wesley Miller, Tucson, Arizona
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This builder worked with the National Association of Home Builders Research Center to build two net-zero energy homes with foam-sheathed masonry walls, low-E windows 2.9 ACH50 air sealing, transfer grilles, ducts in insulated attic, PV, and solar water heating.
38 CFR 59.80 - Amount of grant.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the heating, ventilating, air conditioning, or other service distributed through the building via ducts, pipes, wires, or other connecting device. Fixed equipment must be installed during construction... under this part may not include the cost of: (1) Land acquisition; (2) Maintenance or repair work; or (3...
38 CFR 59.80 - Amount of grant.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the heating, ventilating, air conditioning, or other service distributed through the building via ducts, pipes, wires, or other connecting device. Fixed equipment must be installed during construction... under this part may not include the cost of: (1) Land acquisition; (2) Maintenance or repair work; or (3...
38 CFR 59.80 - Amount of grant.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to the heating, ventilating, air conditioning, or other service distributed through the building via ducts, pipes, wires, or other connecting device. Fixed equipment must be installed during construction... under this part may not include the cost of: (1) Land acquisition; (2) Maintenance or repair work; or (3...
38 CFR 59.80 - Amount of grant.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to the heating, ventilating, air conditioning, or other service distributed through the building via ducts, pipes, wires, or other connecting device. Fixed equipment must be installed during construction... under this part may not include the cost of: (1) Land acquisition; (2) Maintenance or repair work; or (3...
Defence Science and Technology Organisation.
1983-01-01
impacto (vlnv borne debis 2 1 with weapon guidance. remotely piloted aircraft and gun propulsion resear’h )r I.\\. Napier weapons systems are rocket...the Tasnman ticeanic front which extends ducting over water, ambient seta notise and the thetry oL between Australia and New Zealand. This work ho
Zoepf, Thomas; Maldonado-Lopez, Evelyn J; Hilgard, Philip; Schlaak, Joerg; Malago, Massimo; Broelsch, Christoph E; Treichel, Ulrich; Gerken, Guido
2005-11-01
Endoscopic treatment of biliary strictures after liver transplantation is a therapeutic challenge. In particular, outcomes of endoscopic therapy of biliary complications in the case of duct-to-duct anastomosis after living related liver transplantation are limited. The aim of this study was to evaluate the feasibility and success of an endoscopic treatment approach to posttransplant biliary strictures (PTBS) after right-sided living donor liver transplantation (RLDLT) with duct-to-duct anastomosis. Ninety patients who received adult-to-adult RLDLT in our center were screened retrospectively with respect to endoscopic treatment of PTBS. Therapy was judged as successful when cholestasis parameters returned to normal and bile duct narrowing was reduced significantly after the completion of therapy. Forty of 90 RLDLT patients received duct-to-duct anastomosis, 12 (30%) showed PTBS. Seven of 12 patients were treated successfully by endoscopy; the remaining 5 patients were treated primarily by surgery. Most patients were treated by balloon dilatation followed by insertion of endoprostheses. A median of 2.5 dilatation sessions were necessary and the median treatment duration was 8 months. One patient developed endoscopy-treatable recurrent stenosis, no surgical intervention was necessary. Mild pancreatitis occurred in 7.9% and cholangitis in 5.3% of the procedures. One minor bleeding episode occurred during sphincterotomy. Bleeding was managed endoscopically. Endoscopic therapy of adult-to-adult right living related liver transplantation with duct-to-duct anastomosis is feasible and frequently is successful. The duct-to-duct anastomosis offers the possibility of endoscopic treatment. Endoscopic treatment of posttransplant biliary strictures is safe, with a low specific complication rate.
Albumin expression distinguishes bile duct adenomas from metastatic adenocarcinoma.
Moy, Andrea P; Arora, Kshitij; Deshpande, Vikram
2016-09-01
Bile duct adenomas may be difficult to distinguish from metastatic carcinomas, particularly well-differentiated pancreatic ductal adenocarcinoma. Prior studies have evaluated the utility of various immunohistochemical markers, although these markers are notable for low sensitivity and/or specificity. The aim of this study was to investigate the utility of albumin and BRAFV600E expression in distinguishing between metastatic pancreatic adenocarcinoma and bile duct adenoma. We studied 26 bile duct adenomas, three bile duct hamartomas, and 158 pancreatic ductal adenocarcinomas. Branched-chain in-situ hybridization (bISH) for albumin was performed; bISH is based on the branched DNA technology, wherein signal amplification is achieved via a series of sequential steps. Additionally, BRAFV600E immunohistochemistry (IHC) was performed on a subset of cases. Twenty-three of 25 (92%) bile duct adenomas were positive for albumin; 18 (72%) showed diffuse staining, and five showed focal staining (20%), including two challenging examples. Two bile duct hamartomas also stained positively. All pancreatic adenocarcinomas were negative for albumin. Seven of 16 (44%) bile duct adenomas and five of 106 (5%) pancreatic ductal adenocarcinomas were positive for BRAFV600E by IHC. The sensitivity and specificity of expression of albumin, as detected by bISH, for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 92% and 100%, respectively; the sensitivity and specificity of BRAFV600E IHC for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 43.8% and 95.3%, respectively. Diagnostically challenging examples of bile duct adenoma may be distinguished from metastatic pancreatic adenocarcinoma by the use of albumin bISH. © 2016 John Wiley & Sons Ltd.
Sasaki, Maho; Hori, Tomohide; Furuyama, Hiroaki; Machimoto, Takafumi; Hata, Toshiyuki; Kadokawa, Yoshio; Ito, Tatsuo; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Kimura, Yusuke; Takamatsu, Yuichi; Kitano, Taku; Yoshimura, Tsunehiro
2017-08-08
BACKGROUND Postoperative bile duct leak following hepatobiliary and pancreatic surgery can be intractable, and the postoperative course can be prolonged. However, if the site of the leak is in the distal bile duct in the main biliary tract, the therapeutic options may be limited. Injection of absolute ethanol into the bile duct requires correct identification of the bile duct, and balloon occlusion is useful to avoid damage to the surrounding tissues, even in cases with non-communicating biliary fistula and bile leak. CASE REPORT Two cases of non-communicating biliary fistula and bile leak are presented; one case following pancreaticoduodenectomy (Whipple's procedure), and one case following laparoscopic cholecystectomy. Both cases were successfully managed by chemical bile duct ablation with absolute ethanol. In the first case, the biliary leak occurred from a fistula of the right posterior biliary tract following pancreaticoduodenectomy. Cannulation of the leaking bile duct and balloon occlusion were achieved via a percutaneous route, and seven ablation sessions using absolute ethanol were required. In the second case, perforation of the bile duct branch draining hepatic segment V occurred following laparoscopic cholecystectomy. Cannulation of the bile duct and balloon occlusion were achieved via a transhepatic route, and seven ablation sessions using absolute ethanol were required. CONCLUSIONS Chemical ablation of the bile duct using absolute ethanol is an effective treatment for biliary leak following hepatobiliary and pancreatic surgery, even in cases with non-communicating biliary fistula. Identification of the bile duct leak is required before ethanol injection to avoid damage to the surrounding tissues.
Biliary and pancreatic ductal dilation in patients on methadone maintenance therapy.
Bates, David D B; Tamayo-Murillo, Dorathy; Kussman, Steven; Luce, Adam; LeBedis, Christina A; Soto, Jorge A; Anderson, Stephan W
2017-03-01
To determine whether the diameter of intrahepatic and extrahepatic bile ducts and pancreatic ducts in patients on methadone maintenance therapy is increased when compared with control subjects. Between January 1, 2000 and March 15, 2013, a total of 97 patients (mean age 49.9, range 22-79, 65 male, 32 female) were identified who were receiving chronic methadone maintenance therapy (MMT) when they underwent imaging with abdominal MRI or a contrast-enhanced abdominopelvic CT. A group of 97 consecutive non-MMT control patients (mean age 51.4, range 21-86, 45 male, 52 female) who underwent imaging with abdominal MRI or contrast-enhanced abdominopelvic CT were identified. Patients with known pancreaticobiliary pathology that may confound biliary ductal measurements were excluded. Blinded interpretation was performed, documenting the diameters of the intrahepatic and extrahepatic bile ducts and pancreatic ducts. Descriptive statistics were performed. Patients on MMT demonstrated increased bile duct diameter, with an average increase in duct diameter of 2.39 mm for the common bile duct (p < 0.001; 95% CI 1.88-2.90 mm), 1.43 mm for the intrahepatic bile ducts (p < 0.001; 95% CI 1.12-1.74 mm), and 0.90 mm for the pancreatic duct (p < 0.001; 95% CI 0.64-1.16 mm). No statistically significant correlation was found between ductal diameters and the daily dose of methadone. Patients on methadone maintenance therapy demonstrate significantly increased intra- and extrahepatic bile duct and pancreatic duct diameter when compared with controls. There was no correlation between the dose of methadone and ductal diameter.
Performance Analysis of a Modular Small-Diamter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
2016-03-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
NASA Technical Reports Server (NTRS)
Long, Lyle N.
1999-01-01
This report describes a project to predict ducted fan noise using massively parallel computers. The investigators are part of a larger team of researchers, most of whom are working at NASA Langley Research Center. The portion of the project described below not only stands alone as an individual research project, it also compliments the NASA Langley work. The write-up included in this report is relatively brief, since the details are described in technical papers.
NASA Technical Reports Server (NTRS)
Monson, D. J.
1978-01-01
Based on expected advances in technology, the maximum system efficiency and minimum specific mass have been calculated for closed-cycle CO and CO2 electric-discharge lasers (EDL's) and a direct solar-pumped laser in space. The efficiency calculations take into account losses from excitation gas heating, ducting frictional and turning losses, and the compressor efficiency. The mass calculations include the power source, radiator, compressor, fluids, ducting, laser channel, optics, and heat exchanger for all of the systems; and in addition the power conditioner for the EDL's and a focusing mirror for the solar-pumped laser. The results show the major component masses in each system, show which is the lightest system, and provide the necessary criteria for solar-pumped lasers to be lighter than the EDL's. Finally, the masses are compared with results from other studies for a closed-cycle CO2 gasdynamic laser (GDL) and the proposed microwave satellite solar power station (SSPS).
Refraction-based X-ray Computed Tomography for Biomedical Purpose Using Dark Field Imaging Method
NASA Astrophysics Data System (ADS)
Sunaguchi, Naoki; Yuasa, Tetsuya; Huo, Qingkai; Ichihara, Shu; Ando, Masami
We have proposed a tomographic x-ray imaging system using DFI (dark field imaging) optics along with a data-processing method to extract information on refraction from the measured intensities, and a reconstruction algorithm to reconstruct a refractive-index field from the projections generated from the extracted refraction information. The DFI imaging system consists of a tandem optical system of Bragg- and Laue-case crystals, a positioning device system for a sample, and two CCD (charge coupled device) cameras. Then, we developed a software code to simulate the data-acquisition, data-processing, and reconstruction methods to investigate the feasibility of the proposed methods. Finally, in order to demonstrate its efficacy, we imaged a sample with DCIS (ductal carcinoma in situ) excised from a breast cancer patient using a system constructed at the vertical wiggler beamline BL-14C in KEK-PF. Its CT images depicted a variety of fine histological structures, such as milk ducts, duct walls, secretions, adipose and fibrous tissue. They correlate well with histological sections.
Bilateral epididymal sperm granulomas following urethrostomy in a German shepherd dog.
Batista-Arteaga, M; Santana, M; Lozano, O; Niño, T; Alamo, D; Rodríguez, F
2011-08-01
Bilateral enlargement of both epididymes was observed in a 6-year-old German shepherd dog following a pre-scrotal urethrostomy. Testicular parenchyma showed regular structure, and the spermatogenesis and the steroidogenic functions were not modified. However, macroscopic examination of the tail and the body of both epididymes exhibited multiple white and well-delimited foci. Histopathological study of the epididymes confirmed the development of granulomas associated with extravasated spermatozoa. Urethrostomy caused a severe stenosis of the penile urethra, favouring the retention of urine at the urinary bladder. The retrograde pressure exerted by the distension of the urinary bladder could have allowed the urine to reach the prostatic urethra and the deferent ducts and, finally, the epididymes, causing irritation and rupture of the mucous layer of the epididymal duct, the consequent sperm extravasation and the development of sperm granulomas. We speculate that the inadequate surgical resolution of the urethral calculi caused the bladder distension, the subsequent retrograde flow of urine and the development of the lesions. © 2010 Blackwell Verlag GmbH.
Assadourian, R; Chometowski, S; Bourde, J; Poitout, D; Lamy, J
1975-10-01
The association of perforation of the common bile duct, cholecystitis and acute pancreatitis, should be emphasized. Physiopathology of perforation of the bile duct may be compared with that of pancreatitis. Repair of the bile duct may be delicate requiring hepatico-jejunostomy on an isolated loop.
NASA Astrophysics Data System (ADS)
Ramadan, Omar Barka Ab
A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across the duct burner. A considerable amount of detailed parametric experimental data was collected to investigate the performance characteristics of the duct burner. The variables studied (firing rate, mass flow ratio, conical burner pressure drop, blockage ratio, conical burner shield length, premixer geometry and inlet conditions) were all found to play an important role on emissions (NOx and CO), overall duct burner pressure drop and flame stability. The range of firing rates at which surface combustion was maintained for the duct burner was defined by direct observation of the burner surface and monitoring of the temperature in the combustion zone. Flame images were captured for qualitative assessment. The combustion tests results presented in this thesis proved that the design procedures that were implemented to design this novel microturbine conical wire-mesh duct burner were successful. During the course of the combustion tests, the duct burner displayed stable, low emissions operation throughout the surface firing rate range of 148 kW to 328 kW (1574 kW/m 2 to 3489 kW/m2). Emissions of less than 5 ppm (corrected to 15 percent 02) for NOx and CO emissions were recorded, while the duct burner successfully raised the microturbine exhaust gases temperature from about 227°C to as high as 700°C. The overall duct burner pressure drop throughout was consistently below the design limit of 249 Pa.
Computational Fluid Dynamics Analysis Method Developed for Rocket-Based Combined Cycle Engine Inlet
NASA Technical Reports Server (NTRS)
1997-01-01
Renewed interest in hypersonic propulsion systems has led to research programs investigating combined cycle engines that are designed to operate efficiently across the flight regime. The Rocket-Based Combined Cycle Engine is a propulsion system under development at the NASA Lewis Research Center. This engine integrates a high specific impulse, low thrust-to-weight, airbreathing engine with a low-impulse, high thrust-to-weight rocket. From takeoff to Mach 2.5, the engine operates as an air-augmented rocket. At Mach 2.5, the engine becomes a dual-mode ramjet; and beyond Mach 8, the rocket is turned back on. One Rocket-Based Combined Cycle Engine variation known as the "Strut-Jet" concept is being investigated jointly by NASA Lewis, the U.S. Air Force, Gencorp Aerojet, General Applied Science Labs (GASL), and Lockheed Martin Corporation. Work thus far has included wind tunnel experiments and computational fluid dynamics (CFD) investigations with the NPARC code. The CFD method was initiated by modeling the geometry of the Strut-Jet with the GRIDGEN structured grid generator. Grids representing a subscale inlet model and the full-scale demonstrator geometry were constructed. These grids modeled one-half of the symmetric inlet flow path, including the precompression plate, diverter, center duct, side duct, and combustor. After the grid generation, full Navier-Stokes flow simulations were conducted with the NPARC Navier-Stokes code. The Chien low-Reynolds-number k-e turbulence model was employed to simulate the high-speed turbulent flow. Finally, the CFD solutions were postprocessed with a Fortran code. This code provided wall static pressure distributions, pitot pressure distributions, mass flow rates, and internal drag. These results were compared with experimental data from a subscale inlet test for code validation; then they were used to help evaluate the demonstrator engine net thrust.
Giovanni Domenico Santorini (1681-1737): a prominent physician and meticulous anatomist.
Kleinerman, Rachel; John, Alana; Etienne, Denzil; Turner, Benjamin; Shoja, Mohammadali M; Tubbs, R Shane; Loukas, Marios
2014-05-01
Venetian physician Giovanni Domenico Santorini is revered as one of the most industrious and thorough anatomists of the eighteenth century. After receiving his medical degree in Pisa, Santorini worked as a physician and professor of anatomy and obstetrics in Venice. Of interest, he was a student of Malpighi while in Pisa. He quickly established himself as a dynamic lecturer and meticulous dissector. Santorini's anatomical observations include the prostatic venous plexus, accessory pancreatic duct, corniculate cartilage, parietal emissary veins, the risorius muscle, and many other structures. In addition to the detailed descriptions of these structures, he also produced copper plates and illustrations that are revered as "masterpieces" of that era. Santorini published Observationes anatomicae (Anatomical observations) in 1724, however his primary work, which included the description and anatomical drawings of the accessory pancreatic duct, was not published until thirty-eight years after his death. This posthumous release of Jo. Dominici Santorini anatomici summi septedecim tabulae [Giovanni Domenici Santorini, the excellent anatomist's seventeen drawings] was accomplished by Giambattista Morgagni and his disciple, Michael Girardi in 1775. Giovanni Santorini's assiduous dissections have significantly enhanced our knowledge of human anatomy and his work has been immortalized with several anatomical eponyms. Copyright © 2013 Wiley Periodicals, Inc.
Evaluation of a ducted-fan power plant designed for high output and good cruise fuel economy
NASA Technical Reports Server (NTRS)
Behun, M; Rom, F E; Hensley, R V
1950-01-01
Theoretical analysis of performance of a ducted-fan power plant designed both for high-output, high-altitude operation at low supersonic Mach numbers and for good fuel economy at lower fight speeds is presented. Performance of ducted fan is compared with performance (with and without tail-pipe burner) of two hypothetical turbojet engines. At maximum power, the ducted fan has propulsive thrust per unit of frontal area between thrusts obtained by turbojet engines with and without tail-pipe burners. At cruise, the ducted fan obtains lowest thrust specific fuel consumption. For equal maximum thrusts, the ducted fan obtains cruising flight duration and range appreciably greater than turbojet engines.
Laser velocimeter and total pressure measurements in circular-to-rectangular transition ducts
NASA Technical Reports Server (NTRS)
Patrick, William P.; Mccormick, Duane C.
1988-01-01
A comprehensive set of total pressure and three-component laser velocimetry (LV) data were obtained within two circular-to-rectangular transition ducts at low subsonic speeds. This set of reference data was acquired for use in identifying secondary flow mechanisms and for assessing the accuracy of computational procedures for calculating such flows. Data were obtained at the inlet and exit planes of an aspect ratio three duct having a length-to-diameter ratio of one (AR310) and an aspect ratio six duct having a length-to-diameter ratio of three (AR630). Each duct was unseparated throughout its transition section. It is therefore concluded that secondary flows can play an important part in the fluid dynamics of transition ducts and needs to be addressed in computational analysis. The strength of the secondary flows depends on both the aspect ratio and relative axial duct length.
2017-06-13
Adenocarcinoma of the Extrahepatic Bile Duct; Adenocarcinoma of the Gallbladder; Advanced Adult Primary Liver Cancer; Gastrointestinal Cancer; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Erlotinib in Treating Patients With Unresectable Liver, Bile Duct, or Gallbladder Cancer
2013-06-03
Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Agenesis of the gallbladder with hypoplastic cystic duct diagnosed at laparoscopy.
Kwon, A-Hon; Yanagimoto, Hiroaki; Matsui, Yoichi; Imamura, Atsushi
2006-08-01
An 86-year-old man was admitted to our department with complaints of intermittent upper abdominal pain. Ultrasonography of the abdomen showed dilated extrahepatic bile ducts containing stones; however, the gallbladder was not clearly identified. Magnetic resonance cholangiopancreatography showed dilated extrahepatic ducts and choledocholithiasis without gallbladder visualization. The stone extraction was performed with endoscopic sphincterotomy. Three-dimensional images using spiral-computed tomography after intravenous-infusion cholangiography clearly demonstrated an obstruction of the cystic duct. The patient was scheduled for laparoscopic cholecystectomy. At laparoscopy, the gallbladder fossa was not identified on the undersurface of the liver. Despite a thorough examination of the intrahepatic (left-sided within the lesser omentum), retroperitoneal, retrohepatic (within the falciform ligament), retroduodenal, and retropancreatic areas using laparoscopic ultrasonography, the gallbladder was not found. After careful dissection of the hepatoduodenal ligament, the dilated extrahepatic bile duct and a 1-cm length of hypoplastic cystic duct were found. Gallbladder agenesis is usually accompanied by the lack of the cystic duct. The present case is the third report of gallbladder agenesis with a patent or hypoplastic cystic duct.
Kulyapina, Alena; Ochandiano-Caicoya, Santiago; Navarro-Cuellar, Carlos; Navarro-Vila, Carlos
2014-01-01
Introduction: The lesions of the salivary ducts may be idiopathic, post- traumatic, or iatrogenic and lead to sialocele formation with persistent painful facial swelling or cutaneous fistula formation. No consensus on treatment of this condition exists: the options of treatment include needle aspiration, pressure dressings, antisialogogue therapy, radiotherapy, botulinum toxin and surgical approaches as duct repair, diversion, ligation, different drainage systems and even parotidectomy/submaxilectomy. The management and special features of iatrogenic salivary duct injury in patients with oral cancer who underwent head and neck reconstructive surgery has not been described yet. Material and Methods: We present four cases of iatrogenic lesions of salivary ducts and its management in patients with oral cancer. Conclusions: The iatrogenic lesions of salivary ducts are to be taken into account in patients with oral cancer as the distal ends of salivary ducts could be involved in the margins of surgical resection. Different options of treatment of this complication are described. Key words:Sialocele, oral cancer, salivary duct. PMID:25136433
Developing flow in S-shaped ducts. 2: Circular cross-section duct
NASA Technical Reports Server (NTRS)
Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.
1984-01-01
Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.
Lapp, Robert T; Wolf, J Stuart; Faerber, Gary J; Roberts, William W; McCarthy, Sean T; Anderson, Michelle A; Wamsteker, Erik-Jan; Elta, Grace H; Scheiman, James M; Kwon, Richard S
2016-09-01
The need for endoscopic therapy before extracorporeal shock wave lithotripsy (SWL) to facilitate pancreatic duct stone removal is unclear. Predictive factors associated with successful fragmentation and subsequent complete duct clearance are variable. We hypothesize pancreatic duct strictures and large stones, but not pre-SWL endotherapy, correlate with successful fragmentation and complete duct clearance. A retrospective cohort study of patients with pancreaticolithiasis who underwent SWL and endoscopic retrograde cholangiopancreatography between January 2009 and June 2014 was evaluated. Thirty-seven patients were treated. Technical success (TS) of fragmentation was achieved in 22 patients (60%). Technical success was associated with fewer stones and SWL sessions and smaller stone and duct size. By multivariate logistic regression, only duct dilation was associated with TS. Endoscopic success of complete duct clearance was achieved in 29 patients (80%). Endoscopic success was more frequent with stones 12 mm or less and with successful TS. By multivariate logistic regression, stones greater than 12 mm were associated with endoscopic failure. Pre-SWL endotherapy does not affect stone fragmentation. Patients with a dilated duct (>8 mm) and pancreatic stones 12 mm or greater were associated with unsuccessful TS and endoscopic success, respectively, and may benefit from early referral for surgical decompression.
Bile duct anastomotic stricture after pediatric living donor liver transplantation.
Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau
2012-07-01
Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (<18 years old) who underwent LDLT during the period from end of September 1993 to end of November 2010. The diagnosis of BAS was based on clinical, biochemical, histologic, and radiologic results. All patients received left-side grafts. Thirteen patients (16.7%) developed BAS after LDLT. Among them, 3 patients (23.1%) had duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.
Common Bile Duct Stricture After Laparoscopic Cholecystectomy: Case Report
Zoričić, Ivan; Soldo, Ivo; Simović, Ivan; Sever, Marko; Bakula, Branko; Grbavac, Martin; Marušić, Marinko; Soldo, Anamaria
2017-03-01
Despite progress in laparoscopic surgery and increasing surgical experience, the incidence of bile duct injury during laparoscopic cholecystectomy fails to fall below 0.3%-0.6% and it is still higher than those recorded in the era of open cholecystectomy. Bile duct injuries belong to the most serious complications of abdominal surgery in general and often end up with liver transplantation as the only hope for cure. We present a case of a 78-year-old jaundiced male patient who sustained common hepatic duct injury during laparoscopic cholecystectomy eight months earlier. Exploratory laparotomy, ERCP and MRCP revealed a metal clip placed just below hepatic duct confluence and causing stricture of bile duct with dilatation of bile ducts proximal to the level of stenosis (Strasberg classification type E3 injury). Repair of the injury was performed by creating termino-lateral hepaticojejunostomy between the right and left hepatic ducts and retrocolic Roux en-Y jejunal limb. By presenting this case, we wish to emphasize the importance of timely conversion and execution of intraoperative cholangiography in all cases when identification of the structures of Calot’s triangle is not clear enough. Successful treatment of bile duct injury is only possible with joint approach of radiologist, gastroenterologist and experienced hepatobiliary surgeon.
Investigation of the interference effects of mixed flow long duct nacelles on a DC-10 wing
NASA Technical Reports Server (NTRS)
Patel, S. P.; Donelson, J. E.
1982-01-01
Wind tunnel test results utilizing a 4.7 percent scale semispan model in the 11 foot transonic wind tunnel are presented. A low drag long duct nacelle installation for the DC-10 jet transport was developed. A long duct nacelle representative of a CF6-50 mixed flow configuration was investigated on the DC-10-30. The results showed that the long duct nacelle installation located in the same position as the current short duct nacelle and with the current production symmetrical pylon is a relatively low risk installation for the DC-10 aircraft. Tuft observations and analytical boundary layer analysis confirmed that the flow on the nacelle afterbody was attached. A small pylon fairing was evaluated and found to reduce channel peak suction pressures, which resulted in a small drag improvement. The test also confirmed that the optimum nacelle incidence angle is the same as for the short duct nacelle, thus the same engine mount as for the production short duct nacelle can be used for the long duct nacelle installation. Comparison of the inboard wing pylon nacelle channel pressure distributions, with flow through and powered long duct nacelles showed that the power effects did not change the flow mechanism; hence, power effects can be considered negligible.
Long duct nacelle aerodynamic development for DC-10 derivatives
NASA Technical Reports Server (NTRS)
Patel, S. P.; Donelson, J. E.
1980-01-01
The results are presented of a wind tunnel test utilizing a 4.7-percent-scale semispan model of the DC-10 in the Calspan 8-foot transonic wind tunnel. The effect of a revised long-duct nacelle shape on the channel velocities, the incremental drag relative to the baseline long-duct nacelle, and channel velocities for the baseline long-duct nacelle were determined and compared with data obtained at Ames. The baseline and the revised long-duct nacelles are representative of a CF6-50 mixed-flow configuration and were evaluated on a model of a proposed DC-10 stretched-fuselage configuration. The results showed that the revised long-duct nacelle has an appreciable effect on the inboard channel velocities, resulting in an increased channel Mach number. However, the pressure recovery on the nacelle afterbody was about the same for both nacelles. The lift curves for both long-duct nacelle configurations were the same. The channel pressures measured at Calspan were in good agreement with those measured at Ames for the baseline long-duct nacelle. The incremental drag for the revised nacelle was measured as two to four counts (three counts is approximately equal to one percent of the airplane drag) higher than that of the baseline long-duct nacelle.
Viscous flow computations for elliptical two-duct version of the SSME hot gas manifold
NASA Technical Reports Server (NTRS)
Roger, R. P.
1986-01-01
The objective of the effort was to numerically simulate viscous subsonic flow in a proposed elliptical two-duct version of the fuel side Hot Gas Manifold (HGM) for the Space Shuttle Main Engine (SSME). The numerical results were to complement both water flow and air flow experiments in the two-duct geometry performed at NASA-MSFC and Rocketdyne. The three-dimensional character of the HGM consists of two essentially different geometries. The first part of the construction is a concentric shell duct structure which channels the gases from a turbine exit into the second part comprised of two cylindrically shaped transfer ducts. The initial concentric shell portion can be further subdivided into a turnaround section and a bowl section. The turnaround duct (TAD) changes the direction of the mean flow by 180 degress from a smaller radius to a larger radius duct which discharges into the bowl. The cylindrical transfer ducts are attached to the bowl on one side thus providing a plane of symmetry midway between the two. Centerline flow distance from the TAD inlet to the transfer duct exit is approximately two feet. Details of the approach used to numerically simulate laminar or turbulent flow in the HGM geometry are presented. Computational results are presented and discussed.
Koizumi, Yohei; Hirooka, Masashi; Ochi, Hironori; Tokumoto, Yoshio; Takechi, Megumi; Hiraoka, Atsushi; Ikeda, Yoshio; Kumagi, Teru; Matsuura, Bunzo; Abe, Masanori; Hiasa, Yoichi
2015-04-01
This study aimed at prospectively evaluating bile duct anatomy on ultrasonography and evaluating the safety and utility of radiofrequency ablation (RFA) assisted by virtual ultrasonography from gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). The institutional review board approved this study, and patients provided written informed consent prior to entry into the study. Bile duct anatomy was assessed in 201 patients who underwent Gd-EOB-DTPA-enhanced MRI for the evaluation of hepatic tumor. Eighty-one of these patients subsequently underwent RFA assisted by ultrasound imaging. In 23 patients, the tumor was located within 5 mm of the central bile duct, as demonstrated by MRI. Virtual ultrasonography constructed by Gd-EOB-enhanced MRI was able to visualize the common bile duct, left hepatic duct, and right hepatic duct in 96.5, 94.0, and 89.6 % of cases, respectively. The target hepatic tumor nodule and biliary duct could be detected with virtual ultrasonography in all patients, and no severe complications occurred. The running pattern of the bile ducts could be recognized on conventional ultrasound by referencing virtual ultrasonography constructed by Gd-EOB-DTPA-enhanced MRI. RFA assisted by this imaging strategy did not result in bile duct injury.
The statistical evaluation of duct tape end match as physical evidence
NASA Astrophysics Data System (ADS)
Chan, Ka Lok
Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.
Code of Federal Regulations, 2012 CFR
2012-07-01
... exhaust ventilation when used as described in (a) shall be designed to prevent dispersion into the air of... shall be so designed that dusts, fumes, mists, vapors, or gases are not drawn through the work area of employees. (c) Design and operation. Exhaust fans, jets, ducts, hoods, separators, and all necessary...
40 CFR Table 8 to Subpart Sssss of... - Continuous Compliance with Operating Limits
Code of Federal Regulations, 2014 CFR
2014-07-01
... recent performance test; andii. Conducting annually an inspection of all duct work, vents, and capture... process operating parameters within the limits established during the most recent performance test i... processing rate at or below the maximum organic HAP processing rate established during the most recent...
40 CFR Table 8 to Subpart Sssss of... - Continuous Compliance with Operating Limits
Code of Federal Regulations, 2013 CFR
2013-07-01
... recent performance test; andii. Conducting annually an inspection of all duct work, vents, and capture... process operating parameters within the limits established during the most recent performance test i... processing rate at or below the maximum organic HAP processing rate established during the most recent...
40 CFR Table 8 to Subpart Sssss of... - Continuous Compliance with Operating Limits
Code of Federal Regulations, 2012 CFR
2012-07-01
... recent performance test; andii. Conducting annually an inspection of all duct work, vents, and capture... process operating parameters within the limits established during the most recent performance test i... processing rate at or below the maximum organic HAP processing rate established during the most recent...
Ye, Sheng; Dong, Jia-Hong; Duan, Wei-Dong; Ji, Wen-Bing; Liang, Yu-Rong
2017-03-01
The incidence of biliary complications after living donor adult liver transplantation (LDALT) is still high due to the bile duct variation and necessity reconstruction of multiple small bile ducts. The current surgical management of the biliary variants is unsatisfactory. We evaluated the role of a new surgical approach in a complicated hilar bile duct variant (Nakamura type IV and Nakamura type II) under emergent right lobe LDALT for high model for end-stage liver disease score patients. The common hepatic duct (CHD) and the left hepatic duct (LHD) of the donor were transected in a right-graft including short common trunks with right posterior and anterior bile ducts, whereas the LHD of the donor was anastomosed to the CHD and the common trunks of a right-graft bile duct and the recipient CHD was end-to-end anastomosed. Ten of 13 grafts (Nakamura types II, III, and IV) had two or more biliary orifices after right graft lobectomy; seven patients had biliary complications (53.8%). Later, the surgical innovation was carried out in five donors with variant bile duct (four Nakamura type IV and one type II), and, consequently, no biliary or other complications were observed in donors and recipients during 47-53 months of follow-up; significant differences ( P < 0.05) were found when two stages were compared. Our initial experience suggests that, in the urgent condition of LDALT when an alternative live donor was unavailable, a surgical innovation of cutting part of the CHD trunks including variant right hepatic ducts in a complicated donor bile duct variant may facilitate biliary reconstruction and reduce long-term biliary complications.
Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S
2017-07-01
High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (p<0.001) than in non-cancerous FVB/N mouse mammary ducts, perhaps due to rapid washout of contrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.
Schwarz, A.; Beger, H. G.
2005-01-01
Tissue and duct hypertension is considered as a major factor in the etiology of pain in patients with chronic pancreatitis (CP). Duct dilatation is a consequence of duct obstruction due to scars or duct stones. Nevertheless, the procedure of choice, drainage or resection, is still under discussion. We present long-term results of patients operated with duodenum-preserving pancreatic head resection (DPPHR) combined with a Partington-Rochelle duct drainage in cases of chronic pancreatitis with multiple stenosis and dilatation of the side ducts. Methods and patients. From April 1982 to September 2001, in 55 out of 538 patients with chronic pancreatitis, a DPPHR with additionally Partington-Rochelle duct drainage was performed (44 male, 11 female, mean age 45.8 years). Ninety-two percent of the patients suffered from alcoholic pancreatitis. Medical respective pain treatment for chronic pancreatitis was in median 64.5 months prior to surgery. The indications for surgery were in 87% pain, 59% of the patients had an inflammatory mass in the head of the pancreas, 36% a common bile duct stenosis and 5% a severe stenosis of the duodenum. The endocrine function (OGGT) was impaired in 79% of the patients preoperatively. Results. Hospital mortality was 0%, postoperative complications occurred in 11 patients. Follow-up: All except 2 patients were followed up in the outpatient clinic with the mean follow-up time of 69.7 months (8–105 months), the late mortality was 9%. Sixty-eight percent of the patients were completely free of pain, 29% had occasional pain, 3% suffered from a further attack of pancreatitis. Body weight increased in 79%, 58% were professionally rehabilitated. Late postoperative endocrine function was unchanged in 85% (improved in 5%, deteriorated in 10%). Conclusion. The pain control in patients with multiple duct stenosis after duodenum-preserving pancreatic head resection with duct drainage leads to long-standing absence of pain and low recurrence rate of attacks of pancreatitis. PMID:18333173
Srinivasa, Rajiv N; Chick, Jeffrey Forris Beecham; Hage, Anthony N; Gemmete, Joseph J; Murrey, Douglas C; Srinivasa, Ravi N
2018-04-01
To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax. Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded. Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy 2 (range: 701-1,208 μGmy 2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure. Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax. Additional studies are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.
New Generation of ELF/VLF Wave Injection Experiments for HAARP
NASA Astrophysics Data System (ADS)
Sonwalkar, V. S.; Reddy, A.; Watkins, B. J.
2016-12-01
We present a ray tracing study to investigate the feasibility of a new generation of wave injection experiments from HAARP transmitter (L 4.9). Highly successful whistler mode wave injection experiments from SIPLE station, Antarctica, have established the importance of such experiments to study magnetospheric wave-particle interactions, and for cold and hot plasma diagnostics [Helliwell and Katsufrakis, 1974; Carpenter and Miller, 1976; Sonwalkar et al., 1997]. Modulated heating experiments from HAARP have shown that it is possible to launch ELF/VLF waves into the magnetosphere that can be observed on the ground after one-, two-, and multi-hop ducted propagation [Inan et al., 2004]. Recent research has also shown that ionospheric heating experiments using HAARP can lead to the formation of magnetospheric ducts [e.g. Milikh et al., 2010; Fallen et al., 2011]. Collectively, these results indicate that the HAARP (or similar) transmitter can be used first to form ducts on nearby L shells, and then to inject and trap transmitter generated ELF/VLF waves in those ducts. Ray tracing studies using a model magnetosphere shows that ELF/VLF waves in a few kilohertz range can be trapped in ducts with L shells near the HAARP transmitter. For example, 1.5 kHz waves injected from L shell = 4.9 and altitude = 200 km can be trapped in ducts located within 0.3 L of the transmitter L-shell. The duct parameters needed for ray-trapping are typically duct width dL 0.1-0.3 and duct enhancement factor dNe/Ne 10-20% or more. The location of plasmapause with respect to transmitter plays a role in the nature of trapping. The duct locations and parameters required for trapping ELF/VLF waves inside the ducts are consistent with past observations of ducts generated by the HAARP transmitter. Ray tracing calculations provide trapped wave normal angles, time delays, resonant energetic electron energy, estimates of wave intensity inside the duct, on the ground, and on satellites such DEMETER, Van Allen probe, and planned DSX. We discuss the potential of a new generation of wave injection experiments from HAARP transmitter to investigate: duct and ELF/VLF generation by high power HF transmitters, whistler mode wave propagation and wave particle interactions, and cold and hot plasma diagnostics.
Observations of Strong Surface Radar Ducts over the Persian Gulf.
NASA Astrophysics Data System (ADS)
Brooks, Ian M.; Goroch, Andreas K.; Rogers, David P.
1999-09-01
Ducting of microwave radiation is a common phenomenon over the oceans. The height and strength of the duct are controlling factors for radar propagation and must be determined accurately to assess propagation ranges. A surface evaporation duct commonly forms due to the large gradient in specific humidity just above the sea surface; a deeper surface-based or elevated duct frequently is associated with the sudden change in temperature and humidity across the boundary layer inversion.In April 1996 the U.K. Meteorological Office C-130 Hercules research aircraft took part in the U.S. Navy Ship Antisubmarine Warfare Readiness/Effectiveness Measuring exercise (SHAREM-115) in the Persian Gulf by providing meteorological support and making measurements for the study of electromagnetic and electro-optical propagation. The boundary layer structure over the Gulf is influenced strongly by the surrounding desert landmass. Warm dry air flows from the desert over the cooler waters of the Gulf. Heat loss to the surface results in the formation of a stable internal boundary layer. The layer evolves continuously along wind, eventually forming a new marine atmospheric boundary layer. The stable stratification suppresses vertical mixing, trapping moisture within the layer and leading to an increase in refractive index and the formation of a strong boundary layer duct. A surface evaporation duct coexists with the boundary layer duct.In this paper the authors present aircraft- and ship-based observations of both the surface evaporation and boundary layer ducts. A series of sawtooth aircraft profiles map the boundary layer structure and provide spatially distributed estimates of the duct depth. The boundary layer duct is found to have considerable spatial variability in both depth and strength, and to evolve along wind over distances significant to naval operations (100 km). The depth of the evaporation duct is derived from a bulk parameterization based on Monin-Obukhov similarity theory using near-surface data taken by the C-130 during low-level (30 m) flight legs and by ship-based instrumentation. Good agreement is found between the two datasets. The estimated evaporation ducts are found to be generally uniform in depth; however, localized regions of greatly increased depth are observed on one day, and a marked change in boundary layer structure resulting in merging of the surface evaporation duct with the deeper boundary layer duct was observed on another. Both of these cases occurred within exceptionally shallow boundary layers (100 m), where the mean evaporation duct depths were estimated to be between 12 and 17 m. On the remaining three days the boundary layer depth was between 200 and 300 m, and evaporation duct depths were estimated to be between 20 and 35 m, varying by just a few meters over ranges of up to 200 km.The one-way radar propagation factor is modeled for a case with a pronounced change in duct depth. The case is modeled first with a series of measured profiles to define as accurately as possible the refractivity structure of the boundary layer, then with a single profile collocated with the radar antenna and assuming homogeneity. The results reveal large errors in the propagation factor when derived from a single profile.
The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems
NASA Astrophysics Data System (ADS)
Wilson, Eric J. H.
2011-12-01
This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both heating and cooling energy, and ranges from 7% in Los Angeles, CA to 13% in Fairbanks, AK. These results assume a leaky and uninsulated duct system. The potential for savings from cleaning decreases if duct insulation is in place or sealing has been performed. The potential for energy savings is directly related to the distribution system's thermal efficiency, with air conditioner performance also playing a minor role. Results for small commercial buildings with constant air volume HVAC systems and leaky and uninsulated duct systems span a wider range: from -12% in Miami, FL to 30% in Minneapolis, MN. However, for improved ducts or ducts in the conditioned space, small commercial HVAC source energy savings is always negative (down to -17%) for flowrates degradation in the 0--40% range. The sensitivity of these results to duct characteristics (location, leakage, and insulation) and the after-cleaning flowrate, as it varies from an ideal flowrate, was also evaluated. Energy savings can reach up to 80% for some scenarios where clean airflow is severely restricted down to 20% of ideal by poor duct layout or other obstructions not removable by cleaning. In addition, a simplified spreadsheet tool was developed for technicians to use in the field to estimate potential savings resulting from a system cleaning. Measuring the temperature rise across the furnace was found to give less uncertainty than measuring the pressure rise and assuming a fan curve. Despite the uncertainty, the tool can give a general idea of the range of savings possible under various conditions.
Gemcitabine, Oxaliplatin, Tarceva &/or Cisplatin in HCC & Biliary Tree Cancers
2018-06-27
Hepatocellular Carcinoma; Cholangiocellular Carcinoma; Cholangiocarcinoma of the Extrahepatic Bile Duct; Bile Duct Cancer; Periampullary Adenocarcinoma; Gallbladder Cancer; Extrahepatic Bile Duct Cancer
Development of a 32 Inch Diameter Levitated Ducted Fan Conceptual Design
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.; Gallo, Christopher a.; Solano, Paul A.; Thompson, William K.; Vrnak, Daniel R.
2006-01-01
The NASA John H. Glenn Research Center has developed a revolutionary 32 in. diameter Levitated Ducted Fan (LDF) conceptual design. The objective of this work is to develop a viable non-contact propulsion system utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels, and mitigate many of the concerns and limitations encountered in conventional aircraft propulsors. The physical layout consists of a ducted fan drum rotor with blades attached at the outer diameter and supported by a stress tuner ring at the inner diameter. The rotor is contained within a stator. This concept exploits the unique physical dimensions and large available surface area to optimize a custom, integrated, electromagnetic system that provides both the levitation and propulsion functions. The rotor is driven by modulated electromagnetic fields between the rotor and the stator. When set in motion, the time varying magnetic fields interact with passive coils in the stator assembly to produce repulsive forces between the stator and the rotor providing magnetic suspension. LDF can provide significant improvements in aviation efficiency, reliability, and safety, and has potential application in ultra-efficient motors, computers, and space power systems.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Astrophysics Data System (ADS)
Gabb, Timothy P.; Gayda, John; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy® X, Inconel® 617, Inconel® 740, Nimonic® 263, Incoloy® MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Measurements of gas temperature in a radiatively heated particle laden turbulent duct flow
NASA Astrophysics Data System (ADS)
Kim, Ji Hoon; Banko, Andrew; Villafane, Laura; Elkins, Chris; Eaton, John
2017-11-01
Predicting the absorption of radiation through a turbulent, particle laden flow is relevant in atmospheric sciences, turbulent combustion, and in the design of a particle solar receivers. In order to better understand the coupling between the particle phase, the turbulent fluid phase, and the incident radiation, the effects of radiation absorption by disperse inertial particles in a turbulent duct flow was studied experimentally. A fully-developed turbulent duct flow at Reynolds numbers of O(104) , laden with particles at mass loading ratios of 0.1-0.8, was subject to infrared radiation at varying incident powers. The particle Stokes number based on the Kolmogorov length scale was approximately 12, resulting in a preferentially concentrated particle phase. Measurements of the mean and fluctuating components of the gas phase temperature were made along the wall bisector. Results from mean temperature traverses of the gas phase show that a one-dimensional model can account for much of the mean gas temperature rise. Temperature fluctuations due to preferential concentration are significant and can reach approximately 50% of the mean temperature rise. This work was funded by the U.S. Department of Energy under Grant No. DE-NA0002373-1.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Gayda, john; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy(Registered TradeMark) X, Inconel(Registered TradeMark) 617, Inconel(Registered TradeMark) 740, Nimonic(Registered TradeMark) 263, Incoloy(Registered TradeMark) MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Design and performance of duct acoustic treatment
NASA Technical Reports Server (NTRS)
Motsinger, R. E.; Kraft, R. E.
1991-01-01
The procedure for designing acoustic treatment panels used to line the walls of aircraft engine ducts and for estimating the resulting suppression of turbofan engine duct noise is discussed. This procedure is intended to be used for estimating noise suppression of existing designs or for designing new acoustic treatment panels and duct configurations to achieve desired suppression levels.
Influence of Resin Duct Size and Number on Oleoresin Flow in the Southern Pines
John D. Hodges; William W. Elam; Donald R. Bluhm
1981-01-01
The number of radial resin ducts was significantly higher in slash pines than in loblolly, longleaf, or shortleaf. Average width of resin ducts was less in shortleaf than in the other three species. Flow rate of oleoresin was not correlated with size or number of resin ducts for any of the four species.
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
[Syncrhonous carcinosarcoma of the extrahepatic bile duct and gallbladder.
Páramo, Ana Alberca; Valverde, David Padilla; Campos, Pedro Villarejo; Santos, Esther Pilar Garcia; Puche, Jose Luis Bertelli; Guerrero, Paloma Núńez; Delgado, Margarita; Fernindez, Jesus Martin
2016-03-01
Carcinosarcoma is a malignant neoplasm characterized for intermingled epithelial and mesenchymal components. A preoperative suspected diagnosis will allow a radical therapy avoiding a very bad prognosis. We report on a male patient who was operated in our Service with diagnosis of synchronous carcinosarcoma of gallbladder and extrahepatic bile duct and a review of the Medical Literature. A gallblader carcinosarcoma showing extension into common bile duct is very rare, a carcinosarcoma of the bile duct is exceptional, and a synchronous carcinosarcoma ofthe bile duct and gallbladder has not been reported previously.
Chitin in the Silk Gland Ducts of the Spider Nephila edulis and the Silkworm Bombyx mori
Davies, Gwilym J. G.; Knight, David P.; Vollrath, Fritz
2013-01-01
Here we report the detection and localisation of chitin in the cuticle of the spinning ducts of both the spider Nephila edulis and the silkworm Bombyx mori. Our observations demonstrate that the duct walls of both animals contain chitin notwithstanding totally independent evolutionary pathways of the systems. We conclude that chitin may well be an essential component for the construction of spinning ducts; we further conclude that in both species chitin may indicate the evolutionary origin of the spinning ducts. PMID:24015298
2014-09-08
Adenocarcinoma of the Gallbladder; Adenocarcinoma With Squamous Metaplasia of the Gallbladder; Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Stage II Gallbladder Cancer; Stage IIIA Gallbladder Cancer; Stage IIIB Gallbladder Cancer; Stage IVA Gallbladder Cancer; Stage IVB Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer
Using the surface panel method to predict the steady performance of ducted propellers
NASA Astrophysics Data System (ADS)
Cai, Hao-Peng; Su, Yu-Min; Li, Xin; Shen, Hai-Long
2009-12-01
A new numerical method was developed for predicting the steady hydrodynamic performance of ducted propellers. A potential based surface panel method was applied both to the duct and the propeller, and the interaction between them was solved by an induced velocity potential iterative method. Compared with the induced velocity iterative method, the method presented can save programming and calculating time. Numerical results for a JD simplified ducted propeller series showed that the method presented is effective for predicting the steady hydrodynamic performance of ducted propellers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.
Arkelyan, A.M.; Rickard, C.L.
1962-04-17
A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)
Common bile duct stricture as a late complication of upper abdominal radiotherapy.
Cherqui, D; Palazzo, L; Piedbois, P; Charlotte, F; Duvoux, C; Duron, J J; Fagniez, P L; Valla, D
1994-06-01
We report the cases of two patients who developed symptomatic common bile duct stricture 10 years after upper abdominal radiotherapy for malignant lymphoma. Both patients were in complete remission and presented with marked obstructive jaundice. Endosonography was useful in both cases and showed segmental thickening of the bile duct wall narrowing in the lumen. Both patients underwent surgical exploration, confirming biliary obstruction due to intrinsic wall thickening, and had successful biliary drainage by Roux-en-Y hepatico-jejunostomy. Histological examination of the resected bile duct, in one case, and of a bile duct biopsy, in the other, was consistent with late irradiation injury. We conclude that stricture may be a delayed consequence of radiotherapy applied to normal bile ducts.
Lundholm, Gunnar
1983-01-01
In a Stirling cycle engine having a plurality of working gas charges separated by pistons reciprocating in cylinders, the total gas content is minimized and the mean pressure equalization among the serial cylinders is improved by using two piston rings axially spaced at least as much as the piston stroke and by providing a duct in the cylinder wall opening in the space between the two piston rings and leading to a source of minimum or maximum working gas pressure.
1987-02-26
little about the work being done in other parts of the Third World1 to , develop appropriate technologies or new pro- ducts or about the impact of...both within and without the country. The ^Pf*1: ment of National Parks and Wild Life and the police are working flat out to bring the poaching under...bringing in many cattle and goats, while game poaching is increasing rapidly. .An official report recently pre- pared by representatives of the
Experiments on H2-O2MHD power generation
NASA Technical Reports Server (NTRS)
Smith, J. M.
1980-01-01
Magnetohydrodynamic power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, axial duct location within the magnetic field, generator loading, B-field strength, and electrode breakdown voltage were investigated. For the operating conditions of these experiments, it is found that the power output increases with the square of the B-field and can be limited by choking of the channel or interelectrode voltage breakdown which occurs at Hall fields greater than 50 volts/insulator. Peak power densities of greater than 100 MW/cu M were achieved.
NASA Astrophysics Data System (ADS)
Pisarev, P. V.; Anoshkin, A. N.; Pan'kov, A. A.
2016-10-01
The present work formulates the physical and mathematical models capable to forecast acoustic properties of resonance cells in sound absorbing structures. Distribution of acoustic pressure inside the duct and on sidewall cell was found, loss factor of output acoustic pressure wave was calculated for variety of geometric forms of cell's chamber and neck for monochromatic wave in 100-600Hz frequency range. Analysis of the acoustic pressure fields revealed that cell neck geometry strongly influences on cell resonant frequency and on outlet acoustic pressure loss factor. The effectiveness of the proposed by the authors biconical design of the resonant cell was proved, which increased acoustic radiation at the resonance frequency resulting significant increase of loss ratio of wave acoustic pressure at duct outlet.
Kienzle, H F
1999-01-01
The Expert Commission for medical malpractice which is part of the Medical Chamber of Nordrhein received about 60 applications in connection with laparoscopic cholecystectomy; as of August 1998 5 complaints were let off and 11 of them are still being considered. So far 44 complaints have been considered and in 25 of them medical malpractice has been established. The medical malpractice detected laparoscopic cholecystectomy cases were mainly bile duct injuries of which 13 required a biliodigestive anastomosis for reconstruction, four cases required and end-to-end anastomosis and in one case a T-tube drainage was needed. The youngest one of these patients was 21 years old, the oldest one was 61 years old. Four times the bile duct injury was not considered as malpractice, because it could be intraoperatively made out and immediately treated. Trocar injuries were twice a cause for malpractice and once it was not. Each of the following cases was also recognized as a malpractice. One lost gallstone one dislocated Roedersnare, one electric injury, one delayed reintervention and one insufficient information. The following cases were decided as non-malpractice: in two cases a slipped clip, in five cases subhepatical hematoma/abscess, in three cases a secondary bleeding, once a lesion of the splenic capsule and finally a running sore with subsequent incisional hernia. Three courses of treatment with consequence of death also contained mistakes: one electric injury of the bowel, one bile duct lesion and one information rebuke. The bile duct injury is the most considerable risk for laparoscopic cholecystectomy and implies also a high risk for the future health. The experienced surgeon distinguishes himself by the fact that he is right about the situation and converts sooner that later to conventional cholecystectomy if there's any doubt. In open surgery the principle is applied that structures may be only divided when they are clearly identified. The same goes even on a wider scale for laparoscopic surgery too.
Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp
PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct andmore » leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.« less
PMR Graphite Engine Duct Development
NASA Technical Reports Server (NTRS)
Stotler, C. L.; Yokel, S. A.
1989-01-01
The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.
Lesions of the segmental and lobar hepatic ducts.
Longmire, W P; Tompkins, R K
1975-01-01
Despite reports to the contrary, unobstructed drainage of 50% of an otherwise normal liver through either the right or left uninfected hepatic duct is adequate to restore normal liver function, even if the obstructed lobe remains in place. An undrained liver lobe, if present, may require no further treatment. As long as it is completely obstructed and uninfected, it will undergo a progressive asymptomatic atrophy. Cholangitis invariably develops behind a partial lobar ductal obstruction, producing jaundice, pruritis, and fever. Unless unobstructed, uninfected biliary flow can be achieved through a segmental or lobar duct, it is better that the duct be completely obstructed and the affected liver parenchyma allowed to atrophy, provided there is normal biliary flow from the residual 50% of liver. This concept is important in the management of injured anomalous segmental or lobar hepatic duct and in the palliative treatment of bile duct carcinoma. Localized intrahepatic infections communicating with abnormal biliary ducts will require hepatic resection of the infected parenchyma and ducts for cure. The abnormality may be saccular dilatation of the intrahepatic ductal system with abscess formation or intrahepatic abscess associated with stenosis of the ductal system from trauma to the duct, to the duct and liver, or to retained intrahepatic stones. Diffusely situated intrahepatic abscesses secondary to ductal abnormalities can be treated with systemic antibiotics, local drainage of a dmoninant abscess, and efforts to improve biliary drainage. Images Fig. 4. Fig. 5. Fig. 6. Fig. 8. Fig. 9. Fig. 10. Figs. 11A and B Figs. 12A and B. Fig. 13. Fig. 14. Fig. 15. Fig. 16. Fig. 17. PMID:1180585
Evaluation of Flush-Mounted, S-Duct Inlets with Large Amounts of Boundary Layer Ingestion
NASA Technical Reports Server (NTRS)
Berrier, Bobby L.; Morehouse, Melissa B.
2003-01-01
A new high Reynolds number test capability for boundary layer ingesting inlets has been developed for the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. Using this new capability, an experimental investigation of four S-duct inlet configurations with large amounts of boundary layer ingestion (nominal boundary layer thickness of about 40% of inlet height) was conducted at realistic operating conditions (high subsonic Mach numbers and full-scale Reynolds numbers). The objectives of this investigation were to 1) provide a database for CFD tool validation on boundary layer ingesting inlets operating at realistic conditions and 2) provide a baseline inlet for future inlet flow-control studies. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on duct exit diameter) from 5.1 million to a full-scale value of 13.9 million, and inlet mass-flow ratios from 0.39 to 1.58 depending on Mach number. Results of this investigation indicate that inlet pressure recovery generally decreased and inlet distortion generally increased with increasing Mach number. Except at low Mach numbers, increasing inlet mass-flow increased pressure recovery and increased distortion. Increasing the amount of boundary layer ingestion (by decreasing inlet throat height) or ingesting a boundary layer with a distorted (adverse) profile decreased pressure recovery and increased distortion. Finally, increasing Reynolds number had almost no effect on inlet distortion but increased inlet recovery by about one-half percent at a Mach number near cruise.
Biliary tract enhancement in gadoxetic acid-enhanced MRI correlates with liver function biomarkers.
Noda, Yoshifumi; Goshima, Satoshi; Kajita, Kimihiro; Kawada, Hiroshi; Kawai, Nobuyuki; Koyasu, Hiromi; Matsuo, Masayuki; Bae, Kyongtae T
2016-11-01
To evaluate the association between gadoxetic-acid-enhanced magnetic resonance (MR) imaging measurements and laboratory and clinical biomarkers of liver function and fibrosis. One hundred thirty nine consecutive patients with suspected liver disease or liver tumor underwent gadoxetic-acid-enhanced MR imaging. MR imaging measurements during the hepatobiliary phase included biliary tract structure-to-muscle signal intensity ratio (SIR). These measurements were compared with Child-Pugh classification, end-stage liver disease (MELD) score, and aspartate aminotransferase-to-platelet ratio index (APRI). The SIRs of cystic duct and common bile duct were significantly correlated with Child-Pugh classification (P=0.012 for cystic duct and P<0.0001 for common bile duct), MELD score (P=0.0016 and P=0.0033), and APRI (P=0.0022 and P=0.0015). The sensitivity, specificity, and area under the receiver-operating-characteristic curve were: (74%, 88%, 0.86) with the SIR of common bile duct for the detection of patients with Child-Pugh class B or C; (100%, 87%, 0.94) with the SIR of cystic duct for MELD score (>10); (65%, 76%, 0.70) with the SIR of common bile duct for APRI (>1.5). Gadoxetic-acid contrast enhancement of cystic duct and common bile duct could be used as biomarkers to assess liver function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Advanced Turbofan Duct Liner Concepts
NASA Technical Reports Server (NTRS)
Bielak, Gerald W.; Premo, John W.; Hersh, Alan S.
1999-01-01
The Advanced Subsonic Technology Noise Reduction Program goal is to reduce aircraft noise by 10 EPNdB by the year 2000 relative, to 1992 technology. The improvement goal for nacelle attenuation is 25% relative to 1992 technology by 1997 and 50% by 2000. The Advanced Turbofan Duct Liner Concepts Task work by Boeing presented in this document was in support of these goals. The basis for the technical approach was a Boeing study conducted in 1993-94 under NASA/FAA contract NAS1-19349, Task 6, investigating broadband acoustic liner concepts. As a result of this work, it was recommended that linear double layer, linear and perforate triple layer, parallel element, and bulk absorber liners be further investigated to improve nacelle attenuations. NASA LaRC also suggested that "adaptive" liner concepts that would allow "in-situ" acoustic impedance control also be considered. As a result, bias flow and high-temperature liner concepts were also added to the investigation. The major conclusion from the above studies is that improvements in nacelle liner average acoustic impedance characteristics alone will not result in 25% increased nacelle noise reduction relative to 1992 technology. Nacelle design advancements currently being developed by Boeing are expected to add 20-40% more acoustic lining to hardwall regions in current inlets, which is predicted to result in and additional 40-80% attenuation improvement. Similar advancements are expected to allow 10-30% more acoustic lining in current fan ducts with 10-30% more attenuation expected. In addition, Boeing is currently developing a scarf inlet concept which is expected to give an additional 40-80% attenuation improvement for equivalent lining areas.
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Are duct burners and waste heat... Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam generating units...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Are duct burners and waste heat... Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam generating units...
Results and comparison of Hall and DW duct experiments
NASA Technical Reports Server (NTRS)
Smith, J. M.; Morgan, J. L.
1982-01-01
Experimental data from recent tests of a 45 deg diagonal wall duct are presented and compared with the results of a similar Hall duct. It is shown that while the peak power density of the two devices is approximately equal that the diagonal wall duct produces greater total power output due to its ability to better utilize the available magnetic field.
Bile duct epithelial tight junctions and barrier function
Rao, R.K.; Samak, G.
2013-01-01
Bile ducts play a crucial role in the formation and secretion of bile as well as excretion of circulating xenobiotic substances. In addition to its secretory and excretory functions, bile duct epithelium plays an important role in the formation of a barrier to the diffusion of toxic substances from bile into the hepatic interstitial tissue. Disruption of barrier function and toxic injury to liver cells appear to be involved in the pathogenesis of a variety of liver diseases such as primary sclerosing cholangitis, primary biliary cirrhosis and cholangiocarcinoma. Although the investigations into understanding the structure and regulation of tight junctions in gut, renal and endothelial tissues have expanded rapidly, very little is known about the structure and regulation of tight junctions in the bile duct epithelium. In this article we summarize the current understanding of physiology and pathophysiology of bile duct epithelium, the structure and regulation of tight junctions in canaliculi and bile duct epithelia and different mechanisms involved in the regulation of disruption and protection of bile duct epithelial tight junctions. This article will make a case for the need of future investigations toward our understanding of molecular organization and regulation of canalicular and bile duct epithelial tight junctions. PMID:24665411
Modified duval procedure for small-duct chronic pancreatitis without head dominance.
Oida, Takatsugu; Aramaki, Osamu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao
2011-01-01
In the case of small-duct chronic pancreatitis, surgery for pain relief is broadly divided into resection and drainage procedures. These procedures should be selected according to the location of dominant lesion, diameter of the pancreatic duct and extent of the disease. The appropriate procedure for the treatment of small-duct chronic pancreatitis, especially small-duct chronic pancreatitis without head dominance, remains controversial. We developed the modified Duval procedure for the treatment of small-duct chronic pancreatitis without head dominance and determined the efficacy of this procedure. We retrospectively studied 14 patients who underwent surgical drainage with or without pancreatic resection for chronic pancreatitis with small pancreatic duct (<7mm) without head dominance. These patients were divided into 2 groups; the modified Puestow procedure group and the modified Duval procedure group. No complications occurred in the modified Duval group. In the modified Puestow procedure group, complete and partial pain relief were observed in 62.5%, and 37.5% of patients respectively. In contrast, complete pain relief was observed in all the patients in the modified Duval procedure group. Our modified Duval procedure is useful and should be considered the appropriate surgical technique for the treatment of small-duct chronic pancreatitis without head dominance.
Acoustics flow analysis in circular duct using sound intensity and dynamic mode decomposition
NASA Astrophysics Data System (ADS)
Weyna, S.
2014-08-01
Sound intensity generation in hard-walled duct with acoustic flow (no mean-flow) is treated experimentally and shown graphically. In paper, numerous methods of visualization illustrating the vortex flow (2D, 3D) can graphically explain diffraction and scattering phenomena occurring inside the duct and around open end area. Sound intensity investigation in annular duct gives a physical picture of sound waves in any duct mode. In the paper, modal energy analysis are discussed with particular reference to acoustics acoustic orthogonal decomposition (AOD). The image of sound intensity fields before and above "cut-off" frequency region are found to compare acoustic modes which might resonate in duct. The experimental results show also the effects of axial and swirling flow. However acoustic field is extremely complicated, because pressures in non-propagating (cut-off) modes cooperate with the particle velocities in propagating modes, and vice versa. Measurement in cylindrical duct demonstrates also the cut-off phenomenon and the effect of reflection from open end. The aim of experimental study was to obtain information on low Mach number flows in ducts in order to improve physical understanding and validate theoretical CFD and CAA models that still may be improved.
Furusawa, Norihiko; Kobayashi, Akira; Yokoyama, Takahide; Shimizu, Akira; Motoyama, Hiroaki; Kanai, Keita; Arakura, Norikazu; Yamada, Akira; Kitou, Yoshihiro; Miyagawa, Shin-Ichi
2015-08-01
Among the intrahepatic bile ducts, the biliary system of the left medial sectional bile duct (B4) is known to have relatively complex patterns. The records of 500 patients who had been diagnosed as having hepato-pancreatico-biliary disease were retrospectively studied for anatomical biliary variations of the left liver with special reference to the drainage system of B4 using magnetic resonance images. The left hepatic duct was present in 494 patients (98.8%), whereas it was lacking in 6 patients (1.2%), and these patients exhibited the following B4 confluence patterns: B4 drained into the common hepatic duct in 2 patients (.4%), the right anterior sectional bile duct in 3 patients (.6%), and the right posterior sectional bile duct in 1 patient (.2%). The left hepatic duct was absent more frequently in patients with portal venous variations than in patients with a common branching pattern (8.2% vs .4%, P = .0011). The presently reported data are useful for obtaining a better understanding of the surgical anatomy of the biliary system of the left liver. Copyright © 2015 Elsevier Inc. All rights reserved.
Analysis of sound propagation in ducts using the wave envelope concept
NASA Technical Reports Server (NTRS)
Baumeister, K. J.
1974-01-01
A finite difference formulation is presented for sound propagation in a rectangular two-dimensional duct without steady flow for plane wave input. Before the difference equations are formulated, the governing Helmholtz equation is first transformed to a form whose solution does not oscillate along the length of the duct. This transformation reduces the required number of grid points by an order of magnitude, and the number of grid points becomes independent of the sound frequency. Physically, the transformed pressure represents the amplitude of the conventional sound wave. Example solutions are presented for sound propagation in a one-dimensional straight hard-wall duct and in a two-dimensional straight soft-wall duct without steady flow. The numerical solutions show evidence of the existence along the duct wall of a developing acoustic pressure diffusion boundary layer which is similar in nature to the conventional viscous flow boundary layer. In order to better illustrate this concept, the wave equation and boundary conditions are written such that the frequency no longer appears explicitly in them. The frequency effects in duct propagation can be visualized solely as an expansion and stretching of the suppressor duct.
Observed characteristics of atmospheric ducts over the South China Sea in autumn
NASA Astrophysics Data System (ADS)
Cheng, Yinhe; Zhou, Shengqi; Wang, Dongxiao; Lu, Yuanzheng; Huang, Ke; Yao, Jinglong; You, Xiaobao
2016-05-01
The observed characteristics of lower atmospheric ducts over the South China Sea (SCS) were analyzed based on Global Position Systerm (GPS) radiosonde data collected four times daily during autumn open cruises from 2006 to 2012. Duct occurrence, thickness, and strength over the SCS were about 40%, 150-m thick, and 8 M units, respectively, which were larger than during the summer monsoon period. Most ducts occurred at heights <1 500 m and these ducts easily trap electromagnetic wave clusters with wavelengths <2 m. Diurnal variation of the SCS ducts appeared evident. They occurred more often at midnight at higher altitudes (about 1 100 m), with a thickest layer of about 145 m and less frequently during the evening at lower altitudes (about 800 m), with a thinnest layer of about 125 m. Moreover, ducts during the daytime at a mean height of about 900 m, with the greatest strength of about 10 M units. Furthermore, all duct variables observed over the SCS in autumn decreased from north to south. These findings are useful not only in the design of radar and communication systems, but also for evaluating possible effects of anomalous propagation on meteorological radar and military applications.
NASA Technical Reports Server (NTRS)
Plumblee, H. E., Jr.; Dean, P. D.; Wynne, G. A.; Burrin, R. H.
1973-01-01
The results of an experimental and theoretical study of many of the fundamental details of sound propagation in hard wall and soft wall annular flow ducts are reported. The theory of sound propagation along such ducts and the theory for determining the complex radiation impedance of higher order modes of an annulus are outlined, and methods for generating acoustic duct modes are developed. The results of a detailed measurement program on propagation in rigid wall annular ducts with and without airflow through the duct are presented. Techniques are described for measuring cut-on frequencies, modal phase speed, and radial and annular mode shapes. The effects of flow velocity on cut-on frequencies and phase speed are measured. Comparisons are made with theoretical predictions for all of the effects studies. The two microphone method of impedance is used to measure the effects of flow on acoustic liners. A numerical study of sound propagation in annular ducts with one or both walls acoustically lined is presented.
Energy efficient engine: Turbine transition duct model technology report
NASA Technical Reports Server (NTRS)
Leach, K.; Thurlin, R.
1982-01-01
The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.
Sound radiation from a flanged inclined duct.
McAlpine, Alan; Daymond-King, Alex P; Kempton, Andrew J
2012-12-01
A simple method to calculate sound radiation from a flanged inclined duct is presented. An inclined annular duct is terminated by a rigid vertical plane. The duct termination is representative of a scarfed exit. The concept of a scarfed duct has been examined in turbofan aero-engines as a means to, potentially, shield a portion of the radiated sound from being transmitted directly to the ground. The sound field inside the annular duct is expressed in terms of spinning modes. Exterior to the duct, the radiated sound field owing to each mode can be expressed in terms of its directivity pattern, which is found by evaluating an appropriate form of Rayleigh's integral. The asymmetry is shown to affect the amplitude of the principal lobe of the directivity pattern, and to alter the proportion of the sound power radiated up or down. The methodology detailed in this article provides a simple engineering approach to investigate the sound radiation for a three-dimensional problem.
Davies, G J G; Knight, D P; Vollrath, F
2013-10-01
Silks are fibres produced by spiders, some insects and even a crustacean, and are formed from protein solution by a pulltrusion process that is not well understood. Here we describe three aspects of the functional anatomy of the spinning apparatus in a spider: (i) changes in the diameter of the duct of the silk gland along its length for individuals at different stages of development, (ii) the correlation between the morphology of the duct and size and (iii) changes in the thickness of the wall of the duct. We conclude that in the distal part of the duct both the lumen's geometry and change in diameter with distance remains remarkably constant as the duct increases in length from moult to moult as the spider grows. This suggests constancy in the region where the nascent silk filament is drawn down within the lumen of the duct, which is likely to be fundamental for forming strong and tough fibres. Copyright © 2013 Elsevier Ltd. All rights reserved.
Turbofan aft duct suppressor study
NASA Technical Reports Server (NTRS)
Syed, A. A.; Motsinger, R. E.; Fiske, G. H.; Joshi, M. C.; Kraft, R. E.
1983-01-01
Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.
Noise radiation directivity from a wind-tunnel inlet with inlet vanes and duct wall linings
NASA Technical Reports Server (NTRS)
Soderman, P. T.; Phillips, J. D.
1986-01-01
The acoustic radiation patterns from a 1/15th scale model of the Ames 80- by 120-Ft Wind Tunnel test section and inlet have been measured with a noise source installed in the test section. Data were acquired without airflow in the duct. Sound-absorbent inlet vanes oriented parallel to each other, or splayed with a variable incidence relative to the duct long axis, were evaluated along with duct wall linings. Results show that splayed vans tend to spread the sound to greater angles than those measured with the open inlet. Parallel vanes narrowed the high-frequency radiation pattern. Duct wall linings had a strong effect on acoustic directivity by attenuating wall reflections. Vane insertion loss was measured. Directivity results are compared with existing data from square ducts. Two prediction methods for duct radiation directivity are described: one is an empirical method based on the test data, and the other is a analytical method based on ray acoustics.
A non-local computational boundary condition for duct acoustics
NASA Technical Reports Server (NTRS)
Zorumski, William E.; Watson, Willie R.; Hodge, Steve L.
1994-01-01
A non-local boundary condition is formulated for acoustic waves in ducts without flow. The ducts are two dimensional with constant area, but with variable impedance wall lining. Extension of the formulation to three dimensional and variable area ducts is straightforward in principle, but requires significantly more computation. The boundary condition simulates a nonreflecting wave field in an infinite duct. It is implemented by a constant matrix operator which is applied at the boundary of the computational domain. An efficient computational solution scheme is developed which allows calculations for high frequencies and long duct lengths. This computational solution utilizes the boundary condition to limit the computational space while preserving the radiation boundary condition. The boundary condition is tested for several sources. It is demonstrated that the boundary condition can be applied close to the sound sources, rendering the computational domain small. Computational solutions with the new non-local boundary condition are shown to be consistent with the known solutions for nonreflecting wavefields in an infinite uniform duct.
Guelrud, M; Mendoza, S; Vicent, S; Gomez, M; Villalta, B
1983-02-01
To determine the significance of manometric pressure, measurements of the sphincter of Oddi in a control group and in patients with cholelithiasis with common duct stones with and without recurrent pancreatitis were studied. Sphincter of Oddi pressure was recorded continuously and by station pull-through by a triple lumen catheter. The basal sphincter of Oddi pressure, the mean pressure gradient between common duct and duodenum, and the sphincter of Oddi wave amplitude were measured. There was no significant difference between control subjects and patients with gallstones and common duct stones. In patients with common duct stones and recurrent pancreatitis the basal sphincter of Oddi pressure, the pressure gradient between common duct and duodenum, and the wave amplitude were significantly increased over control patients. These studies suggest that abnormalities in the sphincter of Oddi motor function are more common in patients with common duct stones with recurrent pancreatitis than in similar patients without pancreatitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-09-01
Forced air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as an attic or crawlspace. Any leakage of air to or from the duct system (duct leakage) in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution to this problem is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (sealed attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raisedmore » ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. This case study examines one Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or dropped ceiling chase.« less
Acoustic theory of axisymmetric multisectioned ducts. [reduction of turbofan engine noise
NASA Technical Reports Server (NTRS)
Zorumski, W. E.
1974-01-01
Equations are developed for the acoustic field in a duct system which is made up of a number of connected circular and annular ducts. These equations are suitable for finding the acoustic field inside of and radiated from an aircraft turbofan engine. Acoustic modes are used as generalized coordinates in order to develop a set of matrix equations for the acoustic field. Equations for these modes are given for circular and annular ducts with uniform flow. Modal source equations are derived for point acoustic sources. General equations for mode transmission and reflection are developed and detailed equations are derived for ducts with multiple sections of acoustic treatment and for ducts with circumferential splitter rings. The general theory is applied to the special case of a uniform area circular duct with multisection liners and it is shown that the mode reflection effects are proportional to differences of the acoustic admittances of adjacent liners. A numerical example is given which shows that multisection liners may provide greater noise suppression than uniform liners.
Mitigation of Manhole Events Caused by Secondary Cable Failure
NASA Astrophysics Data System (ADS)
Zhang, Lili
"Manhole event" refers to a range of phenomena, such as smokers, fires and explosions which occur on underground electrical infrastructure, primarily in major cities. The most common cause of manhole events is decomposition of secondary cable initiated by an electric fault. The work presented in this thesis addresses various aspects related to the evolution and mitigation of the manhole events caused by secondary cable insulation failure. Manhole events develop as a result of thermal decomposition of organic materials present in the cable duct and manholes. Polymer characterization techniques are applied to intensively study the materials properties as related to manhole events, mainly the thermal decomposition behaviors of the polymers present in the cable duct. Though evolved gas analysis, the combustible gases have been quantitatively identified. Based on analysis and knowledge of field conditions, manhole events is divided into at least two classes, those in which exothermic chemical reactions dominate and those in which electrical energy dominates. The more common form of manhole event is driven by air flow down the duct. Numerical modeling of smolder propagation in the cable duct demonstrated that limiting air flow is effective in reducing the generation rate of combustible gas, in other words, limiting manhole events to relatively minor "smokers". Besides manhole events, another by-product of secondary cable insulation breakdown is stray voltage. The danger to personnel due to stray voltage is mostly caused by the 'step potential'. The amplitude of step potential as a result of various types of insulation defects is calculated using Finite Element Analysis (FEA) program.
In-duct identification of a rotating sound source with high spatial resolution
NASA Astrophysics Data System (ADS)
Heo, Yong-Ho; Ih, Jeong-Guon; Bodén, Hans
2015-11-01
To understand and reduce the flow noise generation from in-duct fluid machines, it is necessary to identify the acoustic source characteristics precisely. In this work, a source identification technique, which can identify the strengths and positions of the major sound radiators in the source plane, is studied for an in-duct rotating source. A linear acoustic theory including the effects of evanescent modes and source rotation is formulated based on the modal summation method, which is the underlying theory for the inverse source reconstruction. A validation experiment is conducted on a duct system excited by a loudspeaker in static and rotating conditions, with two different speeds, in the absence of flow. Due to the source rotation, the measured pressure spectra reveal the Doppler effect, and the amount of frequency shift corresponds to the multiplication of the circumferential mode order and the rotation speed. Amplitudes of participating modes are estimated at the shifted frequencies in the stationary reference frame, and the modal amplitude set including the effect of source rotation is collected to investigate the source behavior in the rotating reference frame. By using the estimated modal amplitudes, the near-field pressure is re-calculated and compared with the measured pressure. The obtained maximum relative error is about -25 and -10 dB for rotation speeds at 300 and 600 rev/min, respectively. The spatial distribution of acoustic source parameters is restored from the estimated modal amplitude set. The result clearly shows that the position and magnitude of the main sound source can be identified with high spatial resolution in the rotating reference frame.
Double Gallbladder Originating from Left Hepatic Duct: A Case Report and Review of Literature
Gorecki, Piotr J.; Andrei, Valeriu E; Musacchio, Tito
1998-01-01
Background: Double gallbladder is a rare anomaly of the biliary tract. Double gallbladder arising from the left hepatic duct was previously reported only once in the literature. Case Report: A case of symptomatic cholelithiasis in a double gallbladder, diagnosed on preoperative ultrasound, computed tomography (CT) and endoscopic retrograde cholangiopancreatogram (ERCP) is reported. At laparoscopic cholangiography via the accessory gallbladder no accessory cystic duct was visualized. After conversion to open cholecystectomy, the duplicated gallbladder was found to arise directly from the left hepatic duct; it was resected and the duct repaired. Conclusions: We emphasize that a careful intraoperative cholangiographic evaluation of the accessory gallbladder is mandatory in order to prevent inadvertent injury to bile ducts, since a large variety of ductal abnormality may exist. PMID:10036124
Positive predictive value of cholescintigraphy in common bile duct obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.
1986-09-01
Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presencemore » of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct.« less
NASA Technical Reports Server (NTRS)
Fuller, C. R.
1984-01-01
Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.
Lightweight Forms for Epoxy/Aramid Ducts
NASA Technical Reports Server (NTRS)
Mix, E. W.; Anderson, A. N.; Bedford, Donald L., Sr.
1986-01-01
Aluminum mandrels easy to remove. Lightweight aluminum mandrel for shaping epoxy/aramid ducts simplifies and speeds production. In new process, glass-reinforced epoxy/aramid cloth wrapped on aluminum mandrel. Stainless-steel flanges and other hardware fitted on duct and held by simple tooling. Entire assembly placed in oven to cure epoxy. After curing, assembly placed in alkaline bath dissolves aluminum mandrel in about 4 hours. Epoxy/aramid shell ready for use as duct. Aluminum mandrel used to make ducts of various inside diameters up to 6 in. Standard aluminum forms used. Conventional tube-bending equipment produces requisite curves in mandrels.
Leaf seal for transition duct in turbine system
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray
2013-06-11
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a leaf seal contacting the interface member to provide a seal between the interface member and the turbine section.
Choleperitoneum due to intrahepatic bile duct rupture - case report.
Simion, L; Straja, Dn; Prunoiu, Vm; Alecu, M; Brătucu, E
2014-01-01
Non-traumatic perforations of the bile ducts are unfrequently encountered entities, all the more when they affect the intrahepatic bile ducts, exteriorizing their biliary content in the great peritoneal cavity. Reporting such a case has determined the authors to perform a careful overview of the cases present in the literature. An observation that can be made based on these is that the obstruction of the main bile duct due to lithiasis determines, by pressure increase, the dilation of the bile system branches, all on the background of an unknown malformation of the intrahepatic bile ducts. Celsius.
Preliminary Full-Scale Wind-Tunnel Investigation of Wing Ducts for Radiators, Special Report
NASA Technical Reports Server (NTRS)
Silverstein, Abe; Nickle, F. R.
1938-01-01
Wing ducts for liquid-cooled engine radiators have been investigated in the N.A.C.A. full-scale wind tunnel on a large model airplane. Th e tests were made to determine the relative merits of several types of duct and radiator installations for an airplane of a particular des ign. In the test program the principal duct dimensions were system atically varied, and the results are therefore somewhat applicable to the general problems of wing duct design, although they should be co nsidered as preliminary and only indicative of the inherent possibil ities.
Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.
Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko
2016-12-01
Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.
Choledochoscopic Holmium Laser Lithotripsy for Difficult Bile Duct Stones.
Lv, Shangdong; Fang, Zheping; Wang, Aidong; Yang, Jian; Zhang, Wenlong
2017-01-01
The aim of this study was to evaluate the feasibility and efficacy of choledochoscopic holmium laser lithotripsy as a means of removing resistant extrahepatic and intrahepatic bile duct stones. Clinical data on 28 patients who had undergone choledochoscopic holmium laser lithotripsy were analyzed. Complete stone clearance was obtained in 24 patients; small numbers of residual stones in the left or right hepatic duct were found in 4 patients. No severe complications such as hemobilia and bile duct injuries occurred. Choledochoscopic holmium laser lithotripsy is a simple, safe, and effective treatment method for patients with resistant bile duct stones.
Generator stator core vent duct spacer posts
Griffith, John Wesley; Tong, Wei
2003-06-24
Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.
Command Control Group Behaviors. Objective 2. Command Control Training with Simulations
1984-08-01
made to Fort Leavenworth to obtain background information on simulation activities and2 usage, ARTEPs, and other related Army activities such as C SPR...Year Three, with the various volumes focusing on one or more key aspects of training with simulations. 1.5 RELATED ACTIVITIES As the research of Year...One was being conducted, it became apparent that a number of on-going Army activities may impact the final pr3duct and therefore have been, and
Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers
Jiang, Tianyong; Kong, Qingzhao; Wang, Wenxi; Huo, Linsheng; Song, Gangbing
2016-01-01
A post-tensioning tendon duct filled with grout can effectively prevent corrosion of the reinforcement, maintain bonding behavior between the reinforcement and concrete, and enhance the load bearing capacity of concrete structures. In practice, grouting of the post-tensioning tendon ducts always causes quality problems, which may reduce structural integrity and service life, and even cause accidents. However, monitoring of the grouting compactness is still a challenge due to the invisibility of the grout in the duct during the grouting process. This paper presents a stress wave-based active sensing approach using piezoceramic transducers to monitor the grouting compactness in real time. A segment of a commercial tendon duct was used as research object in this study. One lead zirconate titanate (PZT) piezoceramic transducer with marble protection, called a smart aggregate (SA), was bonded on the tendon and installed in the tendon duct. Two PZT patch sensors were mounted on the top outside surface of the duct, and one PZT patch sensor was bonded on the bottom outside surface of the tendon duct. In the active sensing approach, the SA was used as an actuator to generate a stress wave and the PZT sensors were utilized to detect the wave response. Cement or grout in the duct functions as a wave conduit, which can propagate the stress wave. If the cement or grout is not fully filled in the tendon duct, the top PZT sensors cannot receive much stress wave energy. The experimental procedures simulated four stages during the grout pouring process, which includes empty status, half grouting, 90% grouting, and full grouting of the duct. Experimental results show that the bottom PZT sensor can detect the signal when the grout level increases towards 50%, when a conduit between the SA and PZT sensor is formed. The top PZT sensors cannot receive any signal until the grout process is completely finished. The wavelet packet-based energy analysis was adopted in this research to compute the total signal energy received by PZT sensors. Experimental results show that the energy levels of the PZT sensors can reflect the degree of grouting compactness in the duct. The proposed method has the potential to be implemented to monitor the tendon duct grouting compactness of the reinforced concrete structures with post tensioning. PMID:27556470
Resin duct characteristics in the wood of fire-scarred North American conifers
Estelle Arbellay; Markus Stoffel; Elaine K. Sutherland; Kevin T. Smith; Donald A. Falk
2013-01-01
Traumatic resin ducts form in xylem and phloem tissue of conifers in response to abiotic wounding, fungal invasion, and insect attack. Little is known about resin duct characteristics in the wood of fire-scarred trees. The aim of this study is to quantify changes in traits of both axial and radial resin ducts, along with those of associated epithelial cells and...
NASA Astrophysics Data System (ADS)
Mironov, M. A.
2011-11-01
A method of allowing for the spatial sound field structure in designing the sound-absorbing structures for turbojet aircraft engine ducts is proposed. The acoustic impedance of a duct should be chosen so as to prevent the reflection of the primary sound field, which is generated by the sound source in the absence of the duct, from the duct walls.
BMS-247550 in Treating Patients With Liver or Gallbladder Cancer
2014-05-13
Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Extrahepatic Bile Duct Cancer; Localized Gallbladder Cancer; Localized Resectable Adult Primary Liver Cancer; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Cooling air recycling for gas turbine transition duct end frame and related method
Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz
2002-01-01
A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.
Ponderosa pine resin defenses and growth: metrics matter.
Hood, Sharon; Sala, Anna
2015-11-01
Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow unsuccessfully attacked or wounded trees to resist future bark beetle attacks. Forest management that encourages healthy, vigorously growing trees will also favor larger resin ducts, thereby conferring increased constitutive resistance to bark beetle attacks. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Molecular characteristics and alterations during early development of the human vagina
Fritsch, Helga; Richter, Elisabeth; Adam, Nadia
2012-01-01
Unresolved questions remain concerning the derivation of the vagina with respect to the relative contributions from the Müllerian ducts, the urogenital sinus, and the Wolffian ducts. Recent molecular and cellular studies in rodents have opened up a large gap between the level of understanding of vaginal development in mice and understanding of human vaginal development, which is based on histology. To compare the findings in mice with human vaginal development and to address this gap, we analysed molecular characteristics of the urogenital sinus, Wolffian ducts, and Müllerian ducts in 8–14-week-old human specimens using immunohistochemical methods. The monoclonal antibodies used were directed against cytokeratin (CK) 14, CK19, vimentin, laminin, p63, E-cadherin, caspase-3, Ki67, HOX A13, and BMP-4. The immunohistochemical analysis revealed that, during weeks 8–9, the epithelium of the Müllerian ducts became positive for p63 as p63-positive cells that originated from the sinus epithelium reached the caudal tip of the fused Müllerian ducts via the Wolffian ducts. The lumen of the fused Müllerian ducts was closed by an epithelial plug that contained both vimentin-positive and vimentin-negative cells. Subsequently, the resulting epithelial tube enlarged by proliferation of basal p63-positive cells. The first signs of squamous differentiation were detected during week 14, with the appearance of CK14-positive cells. According to our results, all three components, namely, the urogenital sinus, Wolffian ducts, and Müllerian ducts, interacted during the formation of the human vagina. The sinus epithelium provided p63-positive cells, the Wollfian ducts acted as a ‘transporter’, and the Müllerian ducts contributed the guiding structure for the vaginal anlagen. Epithelial differentiation began at the end of the period studied and extended in a caudo-cranial direction. The present study is one of the first to provide up-to-date molecular correlates for human vaginal development that can be compared with the results of cell biological studies in rodents. PMID:22256858
NASA Astrophysics Data System (ADS)
Leung, R. C. K.; So, R. M. C.; Tang, S. K.; Wang, X. Q.
2011-07-01
In-duct devices are commonly installed in flow ducts for various flow management purposes. The structural construction of these devices indispensably creates disruption to smooth flow through duct passages so they exist as structural discontinuities in duct flow. The presence of these discontinuities provides additional possibility of noise generation. In real practice, in-duct devices do not exist alone in any duct system. Even though each in-duct device would generate its own noise, it might be possible that these devices could be properly arranged so as to strengthen the interference between individual noise; thus giving rise to an overall reduction of noise radiation in the in-duct far field. This concept of passive noise control is investigated by considering different configurations of two structural discontinuities of simple form (i.e., a cavity) in tandem in an unconfined flow and in opposing setting within a flow duct. It is known that noise generated by a cavity in unconfined domain (unconfined cavity) is strongly dependent on flow-resonant behavior within the cavity so the interference it produces is merely aeroacoustic. The objective of the present study is to verify the concept of passive noise reduction through enhancement of aeroacoustic interference due to two cavities by considering laminar flow only. A two-dimensional approach is adopted for the direct aeroacoustic calculations using a direct numerical simulation (DNS) technique. The position and geometries of the cavities and the Mach number are varied; the resultant aeroacoustic behavior and acoustic power are calculated. The numerical results are compared with a single cavity case to highlight the effect of introducing additional cavities to the aeroacoustic problem. Resonant flow oscillations occur when two unconfined cavities are very close and the associated acoustic field is very intense with no noise reduction possible. However, for duct aeroacoustics, it is found that a 7.9 db reduction of acoustic power in the downstream side of the duct or a total reduction of ˜6 db is possible with opposing cavities having an offset of half a cavity length. In addition, the reduction is shown to be free from lock-on with trapped modes of the ducts with cavities.
Development of an Experimental Rig for Investigation of Higher Order Modes in Ducts
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Cabell, Randolph H.; Brown, Martha C.
2006-01-01
Continued progress to reduce fan noise emission from high bypass ratio engine ducts in aircraft increasingly relies on accurate description of the sound propagation in the duct. A project has been undertaken at NASA Langley Research Center to investigate the propagation of higher order modes in ducts with flow. This is a two-pronged approach, including development of analytic models (the subject of a separate paper) and installation of a laboratory-quality test rig. The purposes of the rig are to validate the analytical models and to evaluate novel duct acoustic liner concepts, both passive and active. The dimensions of the experimental rig test section scale to between 25% and 50% of the aft bypass ducts of most modern engines. The duct is of rectangular cross section so as to provide flexibility to design and fabricate test duct liner samples. The test section can accommodate flow paths that are straight through or offset from inlet to discharge, the latter design allowing investigation of the effect of curvature on sound propagation and duct liner performance. The maximum air flow rate through the duct is Mach 0.3. Sound in the duct is generated by an array of 16 high-intensity acoustic drivers. The signals to the loudspeaker array are generated by a multi-input/multi-output feedforward control system that has been developed for this project. The sound is sampled by arrays of flush-mounted microphones and a modal decomposition is performed at the frequency of sound generation. The data acquisition system consists of two arrays of flush-mounted microphones, one upstream of the test section and one downstream. The data are used to determine parameters such as the overall insertion loss of the test section treatment as well as the effect of the treatment on a modal basis such as mode scattering. The methodology used for modal decomposition is described, as is a description of the mode generation control system. Data are presented which demonstrate the performance of the controller to generate the desired mode while suppressing all other cut on modes in the duct.
Flow in out-of-plane double S-bonds
NASA Technical Reports Server (NTRS)
Schmidt, M. C.; Whitelaw, J. H.; Yianneskis, M.
1986-01-01
Developing flows in two out-of-plane double S-bend configurations have been measured by laser-Doppler anemometry. The first duct had a rectangular cross-section 40mmx40mm at the inlet and consisted of a uniform area 22.5 deg. - 22.5 deg. S-duct upstream with a 22.5 deg.- 22.5 deg. S- diffuser downstream. The second duct had a circular cross-section and consisted of a 45 deg. - 45 deg. uniform area S-duct upstream with a 22.5 deg. -22.5 deg. S-diffuser downstream. In both configurations the ratio of the mean radius of curvature to the inlet hydraulic diameter was 7.0, the exit-to-inlet area ratio of the diffusers was 1.5 and the ducts were connected so that the centerline of the S-duct lay in a plane normal to that of the S-diffuser. Streamwise and cross-stream velocity components were measured in laminar flow for the rectangular duct and in turbulent flow for both configurations; measurements of the turbulence levels, cross-correlations and wall static pressures were also made in the turbulent flow cases. Secondary flows of the first kind are present in the first S-duct and they are complemented or counteracted by the secondary flows generated by the area expansion and by the curvature of the S-diffusers downstream. Cross-stream velocities with magnitudes up to 0.19 and 0.11 of the bulk velocity were measured in the laminar and turbulent flows respectively in the rectangular duct and six cross-flow vortices were evident at the exit of the duct in both flow cases. The turbulent flow in the circular duct was qualitatively similar to that in the rectangular configuration, but the cross-stream velocities measured at the exit plane were smaller in the circular geometry. The results are presented in sufficient detail and accuracy for the assessment of numerical calculation methods and are listed in tabular form for this purpose.
Xu, H Y; Yu, X P; Feng, R; Hu, H J; Xiao, W W
2017-05-23
Objective: To evaluate the correlation between bile duct injury after transcatheter arterial chemoembolization and the level of hepatic arterial embolization, and to analyze the clinical prognosis of hepatocellular carcinoma patients. Methods: From January18, 2012 to December18, 2014, 21 patients underwent TACE for HCC were retrospectively reviewed, including patients' clinical and pathological data. The clinical outcome and relevant factors for bile duct injury were analyzed. Results: A total of 21 patients were identified with bile duct injury at our single institution. All patients received 48 TACE treatments, including proper hepatic artery (14), left hepatic artery (3), the right hepatic artery (10), left and right hepatic artery (9) and tumor artery branches (12). Thirty-five bile duct injury occurred in 21 patients: 7 cases was close to the tumor, 2 distant to the tumor, 7 at right liver, 2 left liver, 11 both lobes of liver and 6 hepatic hilar. After medical conservative treatment and biliary tract inside and outside drainage, liver function of 10 cases were improved. In four patients with hepatic bile duct stricture and biloma, the effect of drainage was not obvious, which subsequently caused biliary complications such as infection, gallbladder and common bile duct stones. Three patients with liver cirrhosis at decompensation stage developed complications, and one of them died of hepatic encephalopathy. Four patients experienced tumor recurrence during the follow-up period. Conclusions: The location of bile duct injury after transcatheter arterial chemoembolization is quite consistent with the level of hepatic arterial embolization. There may be some blood vessels mainly involved in blood supply of biliary duct. Complete embolism of these vessels may lead to bile duct injuries. Biliary drainage is ineffective in patients with hilar bile duct stricture, and can lead to complications of biliary tract later on.
Tezcaner, Tugan; Dinç, Nadire; Y Karakayalı, Feza; Kırnap, Mahir; Coşkun, Mehmet; Moray, Gökhan; Haberal, Mehmet
2017-01-27
Our aim was to evaluate the influence of the localization of right posterior bile duct anatomy relative to portal vein of the donors on posttransplant bile duct complications. We retrospectively investigated 141 patients who had undergone living donor liver transplant using right hemiliver grafts. The patients were classified based on the pattern of the right posterior bile duct and divided into infraportal and supraportal types. Clinical donor and recipient risk factors and surgical outcomes were compared for their relationship with biliary complications using logistic regression analyses. The 2 groups were similar according to demographic and clinical features. The biliary complication rate was 23.7% (9/38) in the infraportal group and 47.4% (37/78) in the supraportal group (P = .014). An analysis of risk factors for the development of anastomotic bile leak using logistic regression showed that a supraportal right posterior bile duct anatomy was a statistically significant positive predictor, with odds ratio of 18.905 (P = .012; confidence interval, 1.922-185.967). The distance of the right posterior bile duct from confluence was significantly lower in patients with biliary complications than in those without (mean of 7.66 vs 0.40 mm; P = .044). According to receiver operating characteristic analyses, the cut-off point for the length of right bile duct to right posterior bile duct from the hepatic confluence was 9.5 mm regarding presence of complications. Factors influencing bile duct anastomosis leakage were supraportal-type donor bile duct anatomy and length of the right main bile duct from biliary confluence. Hepatic arterial complications were similarly a risk factor for biliary strictures. Because of the multiple factors leading to complications in living donor liver transplant, it is challenging to group these patients by operative risk; however, establishing risk models may facilitate the prediction of complications.
Rizzetto, R; Mansi, A; Panatto, D; Rizzitelli, E; Tinteri, C; Sasso, T; Gasparini, R; Crovari, P
2008-03-01
Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty. The growing use of air-conditioning systems in many public and private buildings aggravates this health risk, especially when these systems are not correctly installed or regularly serviced. The aim of our study was to verify the capacity of Ag+ ions to stop the growth of bacteria and moulds inside the ducts of Heating, Ventilation and Air Conditioning system ducts (HVAC) systems when these ducts were lined with active Ag+ ions zeolite-coated panels. A Y-shaped HVAC model with two branches was used; one branch was made of traditional galvanized iron, as was the whole system, while the other was lined with active Ag+ zeolite-coated polyurethane panels. During the test, samples of dust present inside both ducts were collected and seeded in liquid and solid media to detect bacteria and moulds. The presence of bacteria was also sought in the air emerging from the outlets of both ducts. Tests made on samples of particulate collected from the two different ducts revealed a lower total bacterial load in the samples collected from the Ag+ zeolite-coated duct than in the samples from the traditional Zn galvanized duct. In addition, the values of bacterial load found in the air emerging from the Ag+ ions zeolite-lined duct were 5 times lower than those found in the air from the traditional galvanized iron duct. The utilization of Ag+ zeolite-coated panels in air-conditioning systems could improve the quality of the emerging air in comparison with traditional installations in galvanized iron. This innovation could prove particularly advantageous in the event of accidents during the installation of air-conditioning systems or of contaminated aerosols coming from outside.
... be due to: Cancer of the bile ducts ( cholangiocarcinoma ) Cysts in the liver Liver cancer Pancreatic cancer ... and the A.D.A.M. Editorial team. Bile Duct Cancer Read more Bile Duct Diseases Read more Biopsy ...
Takanashi, Yoshitaka; Honkura, Yohei; Rodriguez-Vazquez, Jose Francisco; Murakami, Gen; Kawase, Tetsuaki; Katori, Yukio
2015-01-01
To investigate developmental changes in the thyroglossal duct, we observed serial sagittal sections of eight embryos (crown-rump length (CRL) 6-12 mm; approximately 5-6 weeks of gestation) as well as serial horizontal or cross-sections of 70 embryos and fetuses (CRL 15-110 mm; 6-15 weeks). In the sagittal sections, the thyroglossal duct was identified as a small sheet or mass of relatively large cells with vacuolization anterior, superior or inferior to the fourth pharyngeal arch artery. However, we found no continuous duct-like structure that reached the thyroid gland. Thus, previous classical schemes might have overestimated the continuity of the duct. Among cross-sections of 70 specimens, we found the thyroglossal duct remnant in only two specimens (CRL 15 mm and 100 mm), in contrast to the pyramidal lobe, which was seen in one-third of the specimens. The duct remnant ran downward along the lateral edge of the hyoid body to reach the anterior aspect of the thyroid cartilage. However, the connection between the pyramidal lobe and the duct remnant was interrupted by the anterior cervical muscles. Therefore, it was unlikely that the thyroglossal duct remnant would more frequently be evident in fetuses than in adults. The highly tortuous course of the duct along the lingual aspect of the hyoid body, which has been reported previously, appeared to become established near term. Descent of the thyroid gland was not evident after the CRL 20 mm stage (6 weeks): the gland appeared to retain its position at the level of the third-sixth cervical vertebrae. Copyright © 2014 Elsevier GmbH. All rights reserved.
T-EUS for Gastrointestinal Disorders: A Multicenter Registry
2017-02-16
Cholangiocarcinoma; Pancreatic Cancer; Bile Duct Cancer; Biliary Stricture; Biliary Obstruction; Stent Obstruction; Proximal Duct Stricture; Distal Duct Stricture; Ampullary Cancer; Biliary Sphincter Stenosis; Impacted Stones; Chronic Pancreatitis; Peri-ampullary Diverticula; Altered Anatomy
... the liver get rid of toxins and wastes. Bile duct cancer is rare. It can happen in the parts ... Itchy skin Fever Abdominal pain Tests to diagnose bile duct cancer may include a physical exam, imaging tests of ...
Heat Transfer in Conical Corner and Short Superelliptical Transition Ducts
NASA Technical Reports Server (NTRS)
Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven
2008-01-01
Local surface heat transfer measurements were experimentally mapped using a transient liquid-crystal heat-transfer technique on the surface of two circular-to-rectangular transition ducts. One has a transition cross section defined by conical corners (Duct 1) and the other by an elliptical equation with changing coefficients (Duct 2). Duct 1 has a length-to-diameter ratio of 0.75 and an exit plane aspect ratio of 1.5. Duct 2 has a length-to-diameter ratio of 1.0 and an exit plane aspect ratio of 2.9. Test results are reported for various inlet-diameter-based Reynolds numbers ranging from 0.45 106 to 2.39 106 and two freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.
Evaluation of several non-reflecting computational boundary conditions for duct acoustics
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Zorumski, William E.; Hodge, Steve L.
1994-01-01
Several non-reflecting computational boundary conditions that meet certain criteria and have potential applications to duct acoustics are evaluated for their effectiveness. The same interior solution scheme, grid, and order of approximation are used to evaluate each condition. Sparse matrix solution techniques are applied to solve the matrix equation resulting from the discretization. Modal series solutions for the sound attenuation in an infinite duct are used to evaluate the accuracy of each non-reflecting boundary conditions. The evaluations are performed for sound propagation in a softwall duct, for several sources, sound frequencies, and duct lengths. It is shown that a recently developed nonlocal boundary condition leads to sound attenuation predictions considerably more accurate for short ducts. This leads to a substantial reduction in the number of grid points when compared to other non-reflecting conditions.
NASA Technical Reports Server (NTRS)
Reichert, B. A.; Hingst, W. R.; Okiishi, T. H.
1991-01-01
An ethylene trace gas technique was used to map out fluid transport and mixing within a circular to rectangular transition duct. Ethylene gas was injected at several points in a cross stream plane upstream of the transition duct. Ethylene concentration contours were determined at several cross stream measurement planes spaced axially within the duct. The flow involved a uniform inlet flow at a Mach number level of 0.5. Statistical analyses were used to quantitatively interpret the trace gas results. Also, trace gas data were considered along with aerodynamic and surface flow visualization results to ascertain transition duct flow phenomena. Convection of wall boundary layer fluid by vortices produced regions of high total pressure loss in the duct. The physical extent of these high loss regions is governed by turbulent diffusion.
Fidelman, Nicholas; Kerlan, Robert K; Laberge, Jeanne M; Gordon, Roy L
2011-06-01
To determine the ability of percutaneous transhepatic cholangiography (PTC) to predict accurately the anatomic location and nature of major bile duct injuries, to examine the contribution of endoscopic retrograde cholangiopancreatography (ERCP) and PTC to the diagnosis of injuries to the low-inserting right posterior segmental ducts, and to compare the ability of radiologists and gastroenterologists to detect injuries to the low-inserting right posterior segmental duct. PTC images and operative reports of 78 consecutive patients who underwent surgical repair of major bile duct injuries at the authors' institution were retrospectively reviewed. The location of injury was assessed according to the Bismuth classification. Images were also evaluated for the presence of a biliary stricture, biliary leak, or both. Imaging observations were compared with findings obtained during surgical biliary reconstruction. PTC correctly predicted the anatomic location of injuries in 85% of patients. Incorrect Bismuth type was assigned in 12 patients. Seven of the errors (58%) originated from the inability to distinguish injuries at the confluence of the lobar ducts from injuries involving the cephalad 2 cm of the common hepatic duct. Injuries to the right posterior segmental duct were detected more often on ERCP images by gastroenterologists than by diagnostic radiologists. In four patients (5%), biliary strictures were masked on PTC by the presence of a concomitant leak. PTC accurately depicts the location and nature of major bile duct injuries in most patients. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Use of a vessel sealant device for cystic duct ligation in the dog.
Marvel, Sarah; Monnet, Eric
2014-11-01
To compare a vessel sealant device to hemostatic clips for cystic duct ligation in a canine cadaveric model. Experimental. Hepatobiliary systems were collected from normal dogs. A microtip pressure transducer was inserted into the common bile duct and a 20-24 g intravenous catheter was placed in a hepatic duct. The cystic duct was ligated with 1 of 3 techniques: vessel sealant device (VSD), 10 mm medium Endoclips™, or 10 mm large Endoclips™ with 6 specimens in each group. Methylene blue was infused until failure, which was recorded as seal/clip failure or retrograde movement of methylene blue into the liver. Mean failure pressure of the medium endoclip group was significantly lower than the large endoclip group (P = .014). There was no difference between the failure pressure of the VSD group and the medium and large endoclip groups (P = .097, P = .34, respectively). Failure by leakage at the cut surface of the cystic duct occurred in 2 specimens in the medium endoclip group while all others failed by retrograde flow of the methylene blue through the hepatic ducts. The vessel sealant device appears comparable to large endoclips for closure of the cystic duct in an acute cadaveric model, while medium endoclips may not fully compress or span the diameter of a cystic duct in large breed dogs and leak at lower pressures. © Copyright 2014 by The American College of Veterinary Surgeons.
Aishima, Shinichi; Tanaka, Yuki; Kubo, Yuichiro; Shirabe, Ken; Maehara, Yoshihiko; Oda, Yoshinao
2014-11-01
Morphologic features and neoplastic potentials of bile duct adenoma (BDA) and von Meyenburg complex (VMC)-like duct arising in chronic liver disease were unknown. Thirty-five BDAs and 12 VMC-like duct lesions were observed in 39 cases with chronic liver disease. BDAs were divided into the EMA-cytoplasmic type (n = 14) and EMA-luminal type (n = 21). EMA-cytoplasmic BDA composed of a proliferation of cuboidal to low-columnar cells forming an open lumen with NCAM(+)/MUC6(-), resembling an interlobular bile duct. EMA-luminal BDA showed uniform cuboidal cells with narrow lumen, and NCAM(++)/MUC6(++), resembling a ductular reaction. VMC-like duct showed positive MUC1 expression and negative MUC6. The expression of S100P, glucose transporter-1 (GLUT-1) and insulin-like growth factor II mRNA-binding protein 3 (IMP-3) were not detected in three lesions. p16 expression was higher than those of the ductular reaction, and the Ki67 and p53 indexes were very low (<1.0%). Large-sized EMA-luminal BDA shows sclerotic stroma. We classified small nodular lesions of ductal or ductular cells in chronic hepatitis and cirrhosis into the following groups: BDA, interlobular bile duct type; BDA, ductular/peribiliary gland type; and VMC-like duct. They may be reactive proliferation rather than neoplastic lesions. © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.
Distribution and Room Air Mixing Risks to Retrofitted Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2014-12-01
An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw atmore » the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.« less
Performance and Flowfield Measurements on a 10-inch Ducted Rotor VTOL UAV
NASA Technical Reports Server (NTRS)
Martin, Preston; Tung, Chee
2004-01-01
A ducted fan VTOL UAV with a 10-inch diameter rotor was tested in the US Army 7-by 10-Foot Wind Tunnel. The test conditions covered a range of angle of attack from 0 to 110 degrees to the freestream. The tunnel velocity was varied from 0 (simulating a hover condition) to 128 ft/sec in propeller mode. A six-component internal balance measured the aerodynamic loads for a range of model configurations. including the isolated rotor, the isolated duct, and the full configuration of the duct and rotor. For some conditions, hotwire velocity surveys were conducted along the inner and outer surface of the duct and across the downstream wake. In addition, fluorescent oil flow visualization allowed the flow separation patterns inside and outside of the duct to be mapped for a few test conditions. Two different duct shapes were tested to determine the performance effects of leading edge radius. For each duct, a range of rotor tip gap from 1%R to 4.5%R was tested to determine the performance penalty in hover and axial flight. Measured results are presented in terms of hover performance, hover performance in a crosswind, and high angle of attack performance in propeller mode. In each case, the effects of both tip gap and duct leading edge radius are illustrated using measurements. Some of the hover performance issues were also studied using a simple analytical method, and the results agreed with the measurements.
Pandanaboyana, Sanjay; Bell, Richard; Bartlett, Adam J; McCall, John; Hidalgo, Ernest
2015-04-01
This meta-analysis aimed to compare outcomes following bile duct reconstruction in patients with primary sclerosing cholangitis (PSC) undergoing liver transplantation depending on whether duct-to-duct or Roux-en-Y anastomosis was utilized. An electronic search was performed of the MEDLINE, EMBASE, PubMed databases using both subject headings (MeSH) and truncated word searches. Pooled risk ratios and mean difference were calculated using the fixed-effects and random-effects models for meta-analysis. Ten studies including 910 patients met the inclusion criteria. There was no difference in the overall incidence of biliary strictures between the two groups [odds ratio (OR) 1.06 (0.68, 1.66); (P = 0.80)]. The anastomotic stricture rate was similar, [OR 1.18 (0.56, 2.50); (P = 0.67)]. Ascending cholangitis was higher in the Roux-en-Y group [OR 2.91 (1.17, 7.23); (P = 0.02)]. Anastomotic bile leak rates, graft survival, PSC recurrence and number of patients diagnosed with cholangiocarcinoma following transplantation were comparable between both groups. Duct-to-duct and Roux-en-Y reconstruction had comparable outcomes. Both techniques are associated with similar incidence of biliary stricture. The bilioenteric reconstruction was associated with a higher risk of cholangitis. The incidence of de novo cholangiocarcinoma was similar in both groups. Duct-to-duct reconstruction should be considered when feasible in patients with PSC. © 2015 Steunstichting ESOT.
Thermionic nuclear reactor with internal heat distribution and multiple duct cooling
Fisher, C.R.; Perry, L.W. Jr.
1975-11-01
A Thermionic Nuclear Reactor is described having multiple ribbon-like coolant ducts passing through the core, intertwined among the thermionic fuel elements to provide independent cooling paths. Heat pipes are disposed in the core between and adjacent to the thermionic fuel elements and the ribbon ducting, for the purpose of more uniformly distributing the heat of fission among the thermionic fuel elements and the ducts.
Prediction of Breast Cancer Risk by Aberrant Methylation in Mammary Duct Lavage
2006-07-01
Assessment of breast epithelial cells obtained by nipple duct lavage (NDL) may have value for breast cancer risk stratification. NDL was performed in 150...contribute to risk stratification. 15. SUBJECT TERMS breast cancer, DNA methylation, Methylation Specific PCR, Nipple Duct Lavage, Risk assessment 16...carcinogenesis. Nipple duct lavage (NDL) is a minimally invasive approach for obtaining breast epithelial cells. Cytological atypia identified in nipple
Liver segment IV hypoplasia as a risk factor for bile duct injury.
Mercado, Miguel Angel; Franssen, Bernardo; Arriola, Juan Carlos; Garcia-Badiola, Artemio; Arámburo, Rigoberto; Elnecavé, Alejandro; Cortés-González, Rubén
2011-09-01
Bile duct injury remains constant in the era of laparoscopic cholecystectomy and misidentification of structures remains one of the most common causes of such injuries. Abnormalities in liver segment IV, which is fully visible during laparoscopic cholecystectomy, may contribute to misidentification as proposed herein. We describe the case of a 36-year-old female who had a bile duct injury during a laparoscopic cholecystectomy where the surgeon noticed an unusually small distance between the gallbladder and the round ligament. We define hypoplasia of liver segment IV as well as describe the variation of the biliary anatomy in the case. We also intend to fit it in a broader spectrum of developmental anomalies that have both hyopoplasia of some portion of the liver and variations in gallbladder and bile duct anatomy that may contribute to bile duct injury. To our knowledge, hypoplasia of liver segment IV has not been suggested in the literature as a risk factor for bile duct injury except in the extreme case of a left-sided gallbladder. Surgeons should be vigilant during laparoscopic cholecystectomy when they become aware of an unusually small distance between the gallbladder bed and the round ligament prior to beginning their dissection, variations in the common bile duct and cystic duct should be expected.
Li, Rong; Zhang, Xiaoxi; Yu, Lan; Zou, Xia; Zhao, Hailu
2016-01-01
The adult pancreatic duct system accommodates endocrine cells that have the potential to produce insulin. Here we report the characterization and distribution of insulin-immunoreactive cells and endocrine cells within the ductal units of adult human pancreas. Sequential pancreas sections from 12 nondiabetic adults were stained with biomarkers of ductal epithelial cells (cytokeratin 19), acinar cells (amylase), endocrine cells (chromogranin A; neuron-specific enolase), islet hormones (insulin, glucagon, somatostatin, pancreatic polypeptide), cell proliferation (Ki-67), and neogenesis (CD29). The number of islet hormone-immunoreactive cells increased from large ducts to the terminal branches. The insulin-producing cells outnumbered endocrine cells reactive for glucagon, somatostatin, or pancreatic polypeptide. The proportions of insulin-immunoreactive count compared with local islets (100% as a baseline) were 1.5% for the main ducts, 7.2% for interlobular ducts, 24.8% for intralobular ducts, 67.9% for intercalated ducts, and 348.9% for centroacinar cells. Both Ki-67- and CD29-labeled cells were predominantly localized in the terminal branches around the islets. The terminal branches also showed cells coexpressing islet hormones and cytokeratin 19. The adult human pancreatic ducts showed islet hormone-producing cells. The insulin-reactive cells predominantly localized in terminal branches where they may retain potential capability for β-cell neogenesis.
Intraductal papillary neoplasm originating from an anomalous bile duct.
Maki, Harufumi; Aoki, Taku; Ishizawa, Takeaki; Tanaka, Mariko; Sakatani, Takashi; Beck, Yoshifumi; Hasegawa, Kiyoshi; Sakamoto, Yoshihiro; Kokudo, Norihiro
2017-04-01
An 82-year-old woman who had been suffering from repeated obstructive jaundice for 7 years was referred to our hospital. Although endoscopic aspiration of the mucin in the common bile duct had been temporally effective, origin of the mucin production had not been detectable. The patient thus had been forced to be on long-term follow-up without curative resection. Endoscopic retrograde cholangioscopy on admission revealed massive mucin in the common bile duct. In addition, an anomalous bile duct located proximal to the gallbladder was identified. Since the lumen of the anomalous duct was irregular and the rest of biliary tree was completely free of suspicious lesions, the anomalous duct was judged to be the primary site. Surgical resection of the segment 4 and 5 of the liver combined with the extrahepatic biliary tract was performed. Pathological diagnosis was compatible to intraductal papillary neoplasm with high-grade intraepithelial dysplasia of the anomalous bile duct. The patient has been free from the disease for 6.5 years after resection. This is the first case of intraductal papillary neoplasm derived from an anomalous bile duct, which was resected after long-term conservative treatment. The present case suggested the slow growing character of natural history of the neoplasm.
NASA Astrophysics Data System (ADS)
Khode, Urmi B.
High Altitude Long Endurance (HALE) airships are platform of interest due to their persistent observation and persistent communication capabilities. A novel HALE airship design configuration incorporates a composite sandwich propulsive hull duct between the front and the back of the hull for significant drag reduction via blown wake effects. The sandwich composite shell duct is subjected to hull pressure on its outer walls and flow suction on its inner walls which result in in-plane wall compressive stress, which may cause duct buckling. An approach based upon finite element stability analysis combined with a ply layup and foam thickness determination weight minimization search algorithm is utilized. Its goal is to achieve an optimized solution for the configuration of the sandwich composite as a solution to a constrained minimum weight design problem, for which the shell duct remains stable with a prescribed margin of safety under prescribed loading. The stability analysis methodology is first verified by comparing published analytical results for a number of simple cylindrical shell configurations with FEM counterpart solutions obtained using the commercially available code ABAQUS. Results show that the approach is effective in identifying minimum weight composite duct configurations for a number of representative combinations of duct geometry, composite material and foam properties, and propulsive duct applied pressure loading.
Wang, Gang; Li, Le; Ma, Yuan; Qu, Feng-Zhi; Zhu, Hong; Lv, Jia-Chen; Jia, Yue-Hui; Wu, Lin-Feng; Sun, Bei
2016-08-01
To compare the early efficacy of external versus internal pancreatic duct drainage after pancreaticoduodenectomy (PD), providing clinical evidence for selecting the optimal approach to pancreatic duct drainage. The clinical data of 395 consecutive patients undergoing PD from 2006 to 2013 were analyzed retrospectively. All the patients were divided into external and internal drainage group. Intraoperative blood loss, surgery duration, postoperative hospitalization duration, mortality rate, PF, and other complications were compared between the two groups. The perioperative relative risk factors that might induce PF were analyzed. External drainage significantly reduced the incidences of post-PD PF, delayed gastric emptying, abdominal infection, bowel obstruction, overall complications, and shortened the healing time of PF (p < .05). The univariate analysis showed that the pancreatic duct drainage method, body mass index (BMI), preoperative serum bilirubin level, perioperative blood transfusion, pancreaticojejunostomy approach, pancreatic texture, pancreatic duct diameter, and primary disease differed markedly between the two groups (p < .05). A multivariate analysis revealed that BMI ≥ 25 kg/m(2), internal pancreatic duct drainage, pancreatic duct diameter <3 mm, soft pancreatic texture, and ampullary disease were independent risk factors for PF. External pancreatic duct drainage can effectively reduce the morbidity of PF and overall complications after PD.
Coupling of Low Speed Fan Stator Vane Unsteady Pressures to Duct Modes: Measured versus Predicted
NASA Technical Reports Server (NTRS)
Sutliff, Daniel L.; Heidelberg, Laurence J.; Envia, Edmane
1999-01-01
Uniform-flow annular-duct Green's functions are the essential elements of the classical acoustic analogy approach to the problem of computing the noise generated by rotor-stator interaction inside the fan duct. This paper investigates the accuracy of this class of Green's functions for predicting the duct noise levels when measured stator vane unsteady surface pressures are used as input to the theoretical formulation. The accuracy of the method is evaluated by comparing the predicted and measured acoustic power levels for the NASA 48 inch low speed Active Noise Control Fan. The unsteady surface pressures are measured,by an array of microphones imbedded in the suction and pressure sides of a single vane, while the duct mode levels are measured using a rotating rake system installed in the inlet and exhaust sections of the fan duct. The predicted levels are computed using properly weighted integrals of measured surface pressure distribution. The data-theory comparisons are generally quite good particularly when the mode cut-off criterion is carefully interpreted. This suggests that, at least for low speed fans, the uniform-flow annular-duct Green's function theory can be reliably used for prediction of duct mode levels if the cascade surface pressure distribution is accurately known.
Experiments on the Recovery of Waste Heat in Cooling Ducts, Special Report
NASA Technical Reports Server (NTRS)
Silverstein, Abe
1939-01-01
Tests have been conducted in the N.A.C.A. full-scale wind tunnel to investigate the partial recovery of the heat energy which is apparently wasted in the cooling of aircraft engines. The results indicate that if the radiator is located in an expanded duct, a part of the energy lost in cooling is recovered; however, the energy recovery is not of practical importance up to airplane speeds of 400 miles per hour. Throttling of the duct flow occurs with heated radiators and must be considered in designing the duct outlets from data obtained with cold radiators in the ducts.
Flexible metallic seal for transition duct in turbine system
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray
2014-04-22
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a flexible metallic seal contacting the interface member to provide a seal between the interface member and the turbine section.
Patent vitellointestinal duct as paraumblical abcess: A rare presentation
Rekhi, Harnam Singh; Mittal, Sushil; Singh, Gurtej; Rekhi, Balwinder Kaur; Dugg, Pankaj
2015-01-01
Introduction Umbilical and paraumblical abscess can occur in children with presenting complaint of discharge from umbilical region. However, patent vitello intestinal duct presenting as paraumblical abscess is rare phenomenon. Presentation of case One year old male child presented with complain of discharge from umbilical region since birth. Incision & drainage done twice thinking it to be paraumblical abscess. Discussion Vitellointestinal duct as abscess is rare presentation but it should be considered as a differential diagnosis of discharging umbilicus as management of abscess and patent duct are different. Conclusion Patent vitellointestinal duct can present as paraumbilical abscess, and it should be kept in differential diagnosis specifically in children. PMID:26301682
Convolution seal for transition duct in turbine system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston
2015-03-10
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a convolution seal contacting the interface member to provide a seal between the interface member and themore » turbine section.« less
A study of internal drag of small-scale ducts at Mach number 4
NASA Technical Reports Server (NTRS)
Graham, L. A.; Hunton, L. W.
1972-01-01
An experimental investigation was made to examine the applicability of methods used to determine internal drag of small ducts and to study some of the problems encountered in assessing momentum losses in such ducts. Test Mach numbers ranged from 3.7 to 4.4 at angles of attack of 0 and 5 degrees and at a constant Reynolds number of 4.3 million per foot. The configurations represented small ducts used to simulate external aerodynamics of air breathing propulsion systems and consisted of wing nacelle models of ducts with circular, square, and rectangular inlets and with a two-dimensional inlet.
Tear-Duct Obstruction and Surgery
... Staying Safe Videos for Educators Search English Español Tear-Duct Obstruction and Surgery KidsHealth / For Parents / Tear- ... year old with little or no treatment. About Tear Ducts Our eyes are continually exposed to dust, ...
... gallstones in the bile duct) Infections in the liver, gallbladder, and bile ducts Symptoms The first symptoms are usually: Fatigue Itching ... varices (enlarged veins) Biliary cirrhosis (inflammation of the bile ducts) Liver failure Persistent jaundice Some people develop infections of ...
... duct, the tube that moves bile from the liver to the small intestine. Bile is a substance that helps with digestion. ... causes of this condition include: Cancer of the bile duct, liver or pancreas Damage and scarring due to a ...
Velidedeoglu, Mehmet; Arikan, Akif Enes; Uludag, Sezgin Server; Olgun, Deniz Cebi; Kilic, Fahrettin; Kapan, Metin
2015-05-01
Due to being a severe complication, iatrogenic bile duct injury is still a challenging issue for surgeons in gallbladder surgery. However, a commonly accepted classification describing the type of injury has not been available yet. This study aims to evaluate ability of six current classification systems to discriminate bile duct injury patterns. Twelve patients, who were referred to our clinic because of iatrogenic bile duct injury after laparoscopic cholecystectomy were reviewed retrospectively. We described type of injury for each patient according to current six different classifications. 9 patients underwent definitive biliary reconstruction. Bismuth, Strasberg-Bismuth, Stewart-Way and Neuhaus classifications do not consider vascular involvement, Siewert system does, but only for the tangential lesions without structural loss of duct and lesion with a structural defect of hepatic or common bile duct. Siewert, Neuhaus and Stewart-Way systems do not discriminate between lesions at or above bifurcation of the hepatic duct. The Hannover classification may resolve the missing aspects of other systems by describing additional vascular involvement and location of the lesion at or above bifurcation.
Application of the PJ and NPS evaporation duct models over the South China Sea (SCS) in winter
Yang, Shaobo; Li, Xingfei; Wu, Chao; He, Xin; Zhong, Ying
2017-01-01
The detection of duct height has a significant effect on marine radar or wireless apparatus applications. The paper presents two models to verify the adaptation of evaporation duct models in the SCS in winter. A meteorological gradient instrument used to measure evaporation ducts was fabricated using hydrological and meteorological sensors at different heights. An experiment on the adaptive characteristics of evaporation duct models was carried out over the SCS. The heights of the evaporation ducts were measured by means of log-linear fit, Paulus-Jeske (PJ) and Naval Postgraduate School (NPS) models. The results showed that NPS model offered significant advantages in stability compared with the PJ model. According the collected data computed by the NPS model, the mean deviation (MD) was -1.7 m, and the Standard Deviation (STD) of the MD was 0.8 m compared with the true value. The NPS model may be more suitable for estimating the evaporation duct height in the SCS in winter due to its simpler system characteristics compared with meteorological gradient instruments. PMID:28273113
Excluded segmental duct bile leakage: the case for bilio-enteric anastomosis.
Patrono, Damiano; Tandoi, Francesco; Romagnoli, Renato; Salizzoni, Mauro
2014-06-01
Excluded segmental duct bile leak is the rarest type of post-hepatectomy bile leak and presents unique diagnostic and management features. Classical management strategies invariably entail a significant loss of functioning hepatic parenchyma. The aim of this study is to report a new liver-sparing technique to handle excluded segmental duct bile leakage. Two cases of excluded segmental duct bile leak occurring after major hepatic resection were managed by a Roux-en-Y hepatico-jejunostomy on the excluded segmental duct, avoiding the sacrifice of the liver parenchyma origin of the fistula. In both cases, classical management strategies would have led to the functional loss of roughly 50 % of the liver remnant. Diagnostic and management implications are thoroughly discussed. Both cases had an uneventful postoperative course. The timing of repair was associated with a different outcome: the patient who underwent surgical repair in the acute phase developed no long-term complications, whereas the patient who underwent delayed repair developed a late stenosis requiring percutaneous dilatation. Roux-en-Y hepatico-jejunostomy on the excluded bile duct is a valuable technique in selected cases of excluded segmental duct bile leakage.
Intraductal papillary mucinous tumors of the pancreas: biology, diagnosis, and treatment.
Grützmann, Robert; Niedergethmann, Marco; Pilarsky, Christian; Klöppel, Günter; Saeger, Hans D
2010-01-01
Pancreatic intraductal papillary mucinous neoplasms (IPMNs) rank among the most common cystic tumors of the pancreas. For a long time they were misdiagnosed as mucinous cystadenocarcinoma, ductal adenocarcinoma in situ, or chronic pancreatitis. Only in recent years have IPMNs been fully recognized as clinical and pathological entities, although their origin and molecular pathogenesis remain poorly understood. IPMNs are precursors of invasive carcinomas. When resected in a preinvasive state patient prognosis is excellent, and even when they are already invasive, patient prognosis is more favorable than with ductal adenocarcinomas. Subdivision into macroscopic and microscopic subtypes facilitates further patient risk stratification and directly impacts treatment. There are main duct and branch duct IPMNs, with the main duct type including the intestinal, pancreatobiliary, and oncocytic types and the branch duct type solely harboring the gastric type. Whereas main duct IPMNs have a high risk for malignant progression, demanding their resection, branch duct IPMNs have a much lower risk for harboring malignancy. Patients with small branch duct/gastric-type IPMNs (<2 cm) without symptoms or mural nodules can be managed by periodic surveillance.
Graves, Claire; Ely, Sora; Idowu, Olajire; Newton, Christopher; Kim, Sunghoon
2017-10-01
Intravenous injection of indocyanine green (ICG) is used to illuminate extrahepatic biliary anatomy. Fluorescence of biliary structures may lower surgical complications that can arise due to inadvertent injury to the common bile duct. We describe a method of injecting ICG directly into the gallbladder to define the cystic duct and common bile duct anatomy. A standard laparoscopic cholecystectomy was performed using a laparoscope with near-infrared imaging capability. Before dissection, the gallbladder was punctured with a cholangiogram catheter or a pigtail catheter to aspirate the bile within the gallbladder. The aspirated bile is mixed with ICG solution, which is reinjected into the gallbladder to fluoresce the gallbladder, cystic duct, and common bile duct structures. Eleven patients underwent direct gallbladder ICG injection for fluorescence cholangiography during cholecystectomy. Direct gallbladder ICG injection clearly defined the extrahepatic biliary anatomy, including the cystic duct-common bile duct junction, by fluorescence. In addition, the dissection plane between the gallbladder and the liver is highlighted with the gallbladder ICG fluorescence. Direct gallbladder ICG injection provides immediate visualization of extrahepatic biliary structures and clarifies the dissection plane between the gallbladder and the liver bed.
Yokode, Masataka; Yamashita, Yukimasa; Zen, Yoh
2017-03-01
Intraductal papillary neoplasms of the bile duct (IPNBs) are recognized as a distinct type of biliary tumor. We herein discuss the possible mechanisms underlying the development of multiple tumors in patients with IPNBs through a case presentation and literature review. A 64-year-old woman initially underwent extended right hepatectomy for IPNB in the right hepatic duct. Although the surgical margin of the common bile duct was tumor-free, recurrence was detected in the intrapancreatic bile duct 26 months later. Both tumors had similar histopathological characteristics (intestinal-type IPNB with high-grade dysplasia, but no invasive cancer). A literature review identified 9 additional cases of multiple IPNBs. Unlike conventional IPNBs, which typically affect the intrahepatic or hilar bile duct, 80% of recurrent multiple tumors developed in the extrahepatic bile duct. Although multicentric tumors have been suggested in such cases, the intrabiliary dissemination of tumor cells appears to be more likely, as the majority of recurrent tumors develop in more distal parts of the bile duct compared with the primary tumor.
NASA Astrophysics Data System (ADS)
Snakowska, Anna; Jurkiewicz, Jerzy; Gorazd, Łukasz
2017-05-01
The paper presents derivation of the impedance matrix based on the rigorous solution of the wave equation obtained by the Wiener-Hopf technique for a semi-infinite unflanged cylindrical duct. The impedance matrix allows, in turn, calculate the acoustic impedance along the duct and, as a special case, the radiation impedance. The analysis is carried out for a multimode incident wave accounting for modes coupling on the duct outlet not only qualitatively but also quantitatively for a selected source operating inside. The quantitative evaluation of the acoustic impedance requires setting of modes amplitudes which has been obtained applying the mode decomposition method to the far-field pressure radiation measurements and theoretical formulae for single mode directivity characteristics for an unflanged duct. Calculation of the acoustic impedance for a non-uniform distribution of the sound pressure and the sound velocity on a duct cross section requires determination of the acoustic power transmitted along/radiated from a duct. In the paper, the impedance matrix, the power, and the acoustic impedance were derived as functions of Helmholtz number and distance from the outlet.
The Development of Duct for a Horizontal Axis Turbine Using CFD
NASA Astrophysics Data System (ADS)
Ghani, Mohamad Pauzi Abdul; Yaacob, Omar; Aziz, Azliza Abdul
2010-06-01
Malaysia is heavily dependent on the fossil fuels to satisfy its energy demand. Nowadays, renewable energy which has attracted great interest is marine current energy, which extracted by a device called a device called marine current turbine. This energy resource has agreat potential to be exploited on a large scale because of its predictability and intensity. This paper will focus on developing a Horizontal Axis Marine Current Turbine (HAMCT) rotor to extract marine current energy suitable for Malaysian sea conditions. This work incorporates the characteristic of Malaysia's ocean of shallow water and low speed current in developing the turbines. The HAMCT rotor will be developed and simulated using CAD and CFD software for various combination of inlet and oulet duct design. The computer simulation results of the HAMCT being developed will be presented.
... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...
Liver and Bile Duct Cancer—Health Professional Version
Liver cancer includes two major types: hepatocellular carcinoma (HCC) and intrahepatic bile duct cancer, also known as cholangiocarcinoma. Find evidence-based information on liver and bile duct cancer treatment, causes and prevention, screening, research, genomics and statistics.
2016-12-01
and spatial variations of EDH and EDS are analyzed to provide an evaporation ducting climatology for the Eastern Mediterranean Sea. The sensitivity...are analyzed to provide an evaporation ducting climatology for the Eastern Mediterranean Sea. The sensitivity of EDH and EDS to certain atmospheric...studies were conducted by K. Raptis (2012) and S. Turk (2010). Raptis (2012) examined “ climatological factors affecting EM surface ducting in the
Duct having oscillatory side wall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sprouse, Kenneth M.
A pump system includes a particulate consolidator pump that has a pump outlet. A duct is coupled to the pump outlet. The duct has a wall that is coupled with an oscillator. The oscillator is operable to oscillate the wall at a controlled frequency. The controlled frequency is selected with respect to breaking static bridging of particulate in the duct due, at least in part, to consolidation of the particulate from a downstream check valve.
Parotid salivary duct stenosis following caudal maxillectomy.
Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E
2014-01-01
Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy.
NASA Astrophysics Data System (ADS)
Chen, Dongliang; Sun, Jinhua; Chen, Sining; Liu, Yi; Chu, Guanquan
2007-01-01
In order to explore the flame propagation characteristics and tulip flame formation mechanism of premixed methane/air mixture in horizontal rectangular ducts, the techniques of Schlieren and high-speed video camera are used to study the flame behaviors of the premixed gases in a closed duct and opened one respectively, and the propagation characteristics in both cases and the formation mechanism of the tulip flame are analyzed. The results show that, the propagation flame in a closed duct is prior to form a tulip flame structure than that in an opened duct, and the tulip flame structure formation in a closed duct is related to the flame propagation velocity decrease. The sharp decrease of the flame propagation velocity is one of the reasons to the tulip flame formation, and the decrease of the flame propagation velocity is due to the decrease of the burned product flow velocity mainly.
Cystic pancreatic neoplasms evaluation by CT and magnetic resonance cholangiopancreatography.
Sahani, Dushyant; Prasad, Srinivasa; Saini, Sanjay; Mueller, Peter
2002-10-01
CT provides limited assistance in the differentiation between serous and mucinous neoplasms. Because of the variability in the radiographic appearance of serous cystadenomas and overlap in CT characteristics with mucinous neoplasms, most serous neoplasms still require ancillary testing such as biopsy to reach a definitive diagnosis. MRCP is useful in differentiating benign and malignant mucinous tumors including IPMT of the pancreas. The presence of mural nodules is suggestive of malignancy; however, the absence of mural nodules does not indicate that the tumor is benign. A maximum main pancreatic duct diameter of greater than 15 mm and diffuse dilatation of the main pancreatic duct are suggestive of malignancy in main duct-type tumors. Among branch duct-type tumors, malignant tumors tend to be larger than benign tumors; however, this finding is variable. The presence of main pancreatic duct dilatation may be helpful in determining malignancy of branch duct-type tumors.
NASA Astrophysics Data System (ADS)
Frolov, V. L.; Rapoport, V. O.; Schorokhova, E. A.; Belov, A. S.; Parrot, M.; Rauch, J.-L.
2016-08-01
In this paper we systematize the results of studying the characteristics of the plasma-density ducts, which was conducted in 2005-2010 during the DEMETER-satellite operation. The ducts are formed at altitudes of about 700 km as a result of the ionospheric F 2 region modification by high-power high-frequency radio waves radiated by the midlatitude SURA heating facility. All the performed measurements are used as the basis for determining the formation conditions for such ducts, the duct characteristics are studied, and the opportunities for the duct influence on the ionosphere-magnetosphere coupling and propagation of radio waves of various frequency ranges are demonstrated. The results of numerical simulation of the formation of such ducts are presented.
Xin, Ying; Zhu, Xin; Wei, Qi; Cai, Xiujun; Wang, Xianfa; Huang, Diyu
2007-03-01
With various kinds of minimal access surgery being introduced, quality of life must be considered as a measure of whether minimal access surgery is good or not. We evaluate the difference in quality of life using two kinds of biliary drainage procedures in laparoscopic common bile duct exploration. Forty cases of laparoscopic common bile duct exploration with cholecystectomy were studied to compare gastrointestinal quality of life index (GIQLI) preoperatively and postoperatively at two, five and sixteen weeks in two groups using different biliary drainage procedures. There was no preoperative GIQLI difference between the two groups. Cases with biliary drainage through the cystic duct achieved earlier recovery. GIQLI of all cases reached normal sixteen weeks postoperatively. Biliary drainage through the cystic duct in laparoscopic common bile duct exploration may help to improve the postoperative GIQLI in patients.
Nondestructive Evaluation of the J-2X Direct Metal Laser Sintered Gas Generator Discharge Duct
NASA Technical Reports Server (NTRS)
Esther, Elizabeth A.; Beshears, Ronald D.; Lash, Rhonda K.
2012-01-01
The J-2X program at NASA's Marshall Space Flight Center (MSFC) procured a direct metal laser sintered (DMLS) gas generator discharge duct from Pratt & Whitney Rocketdyne and Morris Technologies for a test program that would evaluate the material properties and durability of the duct in an engine-like environment. DMLS technology was pursued as a manufacturing alternative to traditional techniques, which used off nominal practices to manufacture the gas generator duct's 180 degree turn geometry. MSFC's Nondestructive Evaluation (NDE) Team performed radiographic, ultrasonic, computed tomographic, and fluorescent penetrant examinations of the duct. Results from the NDE examinations reveal some shallow porosity but no major defects in the as-manufactured material. NDE examinations were also performed after hot-fire testing the gas generator duct and yielded similar results pre and post-test and showed no flaw growth or development.
The Use of a Hemostasis Introducer for Percutaneous Extraction of Bile Duct Stones.
Feisthammel, Juergen; Moche, Micheal; Mossner, Joachim; Hoffmeister, Albrecht
2012-02-01
Choledocholithiasis is defined as presence of at least one gallstone in the bile duct. Those bile duct stones (BDS) usually are extracted by ERCP. In case the bile duct is not accessible endoscopically (e.g. after major abdominal surgery), PTCD has to be performed. Extraction of the stones via PTCD has several risks as are hemorrhage, pancreatitis and injuries of the liver tissue. We here report about our experience with a significant modification of this technique by use of a 13-french hemostasis introducer as a sheath to track the transhepatic access to the bile ducts in order to reduce time and risk. Three patients were treated by use of the reported modification. In all cases, the stones were successfully removable without complications. We demonstrate that the use of a hemostasis introducer for percutaneous extraction of common bile duct stones seems to be promising in terms of shortening hospital stay and increasing patient safety.
A multi-modal solution for the transmission of sound in nonuniform ducts
NASA Technical Reports Server (NTRS)
Eversman, W.
1976-01-01
The method of weighted residuals in the form of a modified Galerkin method with boundary residuals is developed for the study of the transmission of sound in nonuniform ducts carrying a steady compressible flow. In this formulation the steady flow is modeled as essentially one-dimensional but with a kinematic modification to force tangency of the flow at the duct walls. Good agreement has been obtained with known results for transmission and reflection coefficients in hard walled ducts up to near sonic velocities. In ducts with acoustically compliant boundaries good comparisons have been more difficult to achieve except at low Mach numbers. The problem of transmission in a straight, acoustically treated duct with a uniform flow has been formulated and the Galerkin method used with basis functions derived from the case when flow is absent. Results indicate that favorable comparisons with exact computations can be obtained if care is taken in choosing the basis functions.
A Review of Double Common Bile Duct and Its Sequelae.
Kolli, Sindhura; Etienne, Denzil; Reddy, Madhavi; Shahzad, Ghulamullah
2018-02-01
A double or accessory common bile duct (ACBD) is a rare congenital anomaly. We report the case of a 60-year-old American Asian male, who was found to have a double or duplicated common bile duct after being admitted for evaluation of a pancreatic mass. A duplicated bile duct has the same mucosa histologically as a single bile duct. However, the opening of a duplicated bile duct lacks a sphincter allowing retrograde flow of gut contents which results in a higher probability of intraductal calculus formation. On rare occasions, it can predispose to liver abscesses, pancreatitis, pancreatic cancer, gallbladder cancer, gastric cancer, and ampullary cancer depending on the location of the opening of the ACBD. We present an integrative review of the limited cases of ACBD with correlation to the current case and discussion regarding the aspects of diagnosis and management.
[Endoscopic manometry in the common bile duct].
Brandstätter, G; Kratochvil, P; Stupnicki, T; Zenker, G; Justich, E; Resch, M
1982-09-17
Reproducible results were obtained by endoscopic transpapillary pressure measurements with the help of a constantly perfused catheter. Manometric measurements were performed in 51 patients without any premedication. 14 patients with a normal biliary system were compared with 17 patients after cholecystectomy, 14 patients with stones in the common bile duct and 6 patients after papillotomy. Although there were significant differences in the diameter of the common bile duct in the four groups, only the papillotomized patients demonstrated a distinct change of the pressure in the bile duct. In these patients almost no pressure gradient existed between the biliary ducts and the duodenum. On the other hand, there was an increase in intraluminal pressure in the 2 patients with papillary stenosis. Endoscopic manometric measurements in the common bile duct are indicated to obtain reliable data on stenosis of the papilla duodeni, insufficient papillotomy or recurrent stenosis.
Regeneratively cooled transition duct with transversely buffered impingement nozzles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrison, Jay A; Lee, Ching-Pang; Crawford, Michael E
2015-04-21
A cooling arrangement (56) having: a duct (30) configured to receive hot gases (16) from a combustor; and a flow sleeve (50) surrounding the duct and defining a cooling plenum (52) there between, wherein the flow sleeve is configured to form impingement cooling jets (70) emanating from dimples (82) in the flow sleeve effective to predominately cool the duct in an impingement cooling zone (60), and wherein the flow sleeve defines a convection cooling zone (64) effective to cool the duct solely via a cross-flow (76), the cross-flow comprising cooling fluid (72) exhausting from the impingement cooling zone. In themore » impingement cooling zone an undimpled portion (84) of the flow sleeve tapers away from the duct as the undimpled portion nears the convection cooling zone. The flow sleeve is configured to effect a greater velocity of the cross-flow in the convection cooling zone than in the impingement cooling zone.« less