Sample records for dynamic compression screw

  1. Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study.

    PubMed

    Chen, Chao; Yu, Li; Tang, Xin; Liu, Mo-Zhen; Sun, Li-Zhong; Liu, Changjian; Zhang, Zhen; Li, Chang-Zhou

    2017-10-01

    The aim of this study was to compare clinical outcomes of patients with femoral neck fractures treated with the dynamic hip system blade (DHS-BLADE) or cannulated compression screws. Eighty-six patients with femoral neck fractures were treated by closed reduction internal fixation with a DHS-BLADE (n = 42; 18 males and 24 females; mean age: 56.3 years (37-87)) or cannulated compression screws (n = 44; 20 males and 24 females; mean age: 53.8 years (26-83)) between March 2011 and August 2013. The groups were compared with Harris hip score, operation time, surgical blood loss, incision size, hospital stay, and related complications. The average follow-up time was 27 months (range, 24-36 months). There was no significant difference for the operation time, incision size, hospital stay, and Harris hip score between the groups. Also, no statistically significant differences in the rates of nonunion (4.5% vs. 0) and avascular necrosis of the femoral head (9.1% vs. 7.1%) were observed. However, the screw group experienced significantly less surgical blood loss (32.4 ± 24.7 ml) than the blade group (87.2 ± 46.6 ml; P = 0.041). The incidence of femoral neck shortening above 10 mm in the screw group was significantly higher than that in the blade group (15.9% vs. 2.4%, P = 0.031). The blade group had a significantly lower incidence of screw migration than the screw group (4.8% vs. 22.7%, P = 0.016). The DHS-BLADE and cannulated compression screws might be equally effective in terms of postoperative fracture union. However, the DHS-BLADE has advantages over cannulated compression screws for preventing femoral neck shortening, screw migration, and cut-out. Level III, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  2. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating

    PubMed Central

    Tsai, Stanley; Bliven, Emily K.; von Rechenberg, Brigitte; Kindt, Philipp; Augat, Peter; Henschel, Julia; Fitzpatrick, Daniel C.; Madey, Steven M.

    2017-01-01

    Objectives: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. Methods: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. Results: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. Conclusions: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing. PMID:27861456

  3. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  4. Biomechanical evaluation of primary stiffness of tibiotalocalcaneal fusion with intramedullary nails.

    PubMed

    Mückley, Thomas; Eichorn, Stephan; Hoffmeier, Konrad; von Oldenburg, Geert; Speitling, Andreas; Hoffmann, Gunther O; Bühren, Volker

    2007-02-01

    Intramedullary implants are being used with increasing frequency for tibiotalocalcaneal fusion (TTCF). Clinically, the question arises whether intramedullary (IM) nails should have a compression mode to enhance biomechanical stiffness and fusion-site compression. This biomechanical study compared the primary stability of TTCF constructs using compressed and uncompressed retrograde IM nails and a screw technique in a bone model. For each technique, three composite bone models were used. The implants were a Biomet nail (static locking mode and compressed mode), a T2 femoral nail (compressed mode); a prototype IM nail 1 (PT1, compressed mode), a prototype IM nail 2 (PT2, dynamic locking mode and compressed mode), and a three-screw construct. The compressed contact surface of each construct was measured with pressure-sensitive film and expressed as percent of the available fusion-site area. Stiffness was tested in dorsiflexion and plantarflexion (D/P), varus and valgus (V/V), and internal rotation and external rotation (I/E) (20 load cycles per loading mode). Mean contact surfaces were 84.0 +/- 6.0% for the Biomet nail, 84.0 +/- 13.0% for the T2 nail, 70.0 +/- 7.2% for the PTI nail, and 83.5 +/- 5.5% for the compressed PT2 nail. The greatest primary stiffness in D/P was obtained with the compressed PT2, followed by the compressed Biomet nail. The dynamically locked PT2 produced the least primary stiffness. In V/V, PT1 had the (significantly) greatest primary stiffness, followed by the compressed PT2. The statically locked Biomet nail and the dynamically locked PT2 had the least primary stiffness in V/V. In I/E, the compressed PT2 had the greatest primary stiffness, followed by the PT1 and the T2 nails, which did not differ significantly from each other. The dynamically locked PT2 produced the least primary stiffness. The screw construct's contact surface and stiffness were intermediate. The IM nails with compression used for TTCF produced good contact surfaces and primary stiffness. They were significantly superior in these respects to the uncompressed nails and the screw construct. The large contact surfaces and great primary stiffness provided by the IM nails in a bone model may translate into improved union rates in patients who have TTCF.

  5. Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates

    PubMed Central

    Hu, Xin-Jia; Wang, Hua

    2017-01-01

    The aim of the present study was to investigate the biomechanical effects of varying the length of a limited contact-dynamic compression plate (LC-DCP) and the number and position of screws on middle tibial fractures, and to provide biomechanical evidence regarding minimally invasive plate osteosynthesis (MIPO). For biomechanical testing, 60 tibias from cadavers (age at mortality, 20–40 years) were used to create middle and diagonal fracture models without defects. Tibias were randomly grouped and analyzed by biomechanic and three-dimensional (3D) finite element analysis. The differences among LC-DCPs of different lengths (6-, 10- and 14-hole) with 6 screws, 14-hole LC-DCPs with different numbers of screws (6, 10 and 14), and 14-hole LC-DCPs with 6 screws at different positions with regard to mechanical characteristics, including compressing, torsion and bending, were examined. The 6-hole LC-DCP had greater vertical compression strain compared with the 10- and 14-hole LC-DCPs (P<0.01), and the 14-hole LC-DCP had greater lateral strain than the 6- and 10-hole LC-DCPs (P<0.01). Furthermore, significant differences in torque were observed among the LC-DPs of different lengths (P<0.01). For 14-hole LC-DCPs with different numbers of screws, no significant differences in vertical strain, lateral strain or torque were detected (P>0.05). However, plates with 14 screws had greater vertical strain compared with those fixed with 6 or 10 screws (P<0.01). For 4-hole LC-DCPs with screws at different positions, vertical compression strain values were lowest for plates with screws at positions 1, 4, 7, 8, 11 and 14 (P<0.01). The lateral strain values and vertical strain values for plates with screws at positions 1, 3, 6, 9, 12 and 14 were significantly lower compared with those at the other positions (P<0.01), and torque values were also low. Thus, the 14-hole LC-DCP was the most stable against vertical compression, torsion and bending, and the 6-hole LC-DCP was the least stable. However, the use of 14 screws with a 14-hole LC-DCP provided less stability against bending than did 6 or 10 screws. Furthermore, fixation with distributed screws, in which some screws were close to the fracture line, provided good stability against compression and torsion, while fixation with screws at the ends of the LC-DCP provided poor stability against bending, compressing and torsion. PMID:28781632

  6. Dorsal Plating of Unstable Scaphoid Fractures and Nonunions.

    PubMed

    Bain, Gregory I; Turow, Arthur; Phadnis, Joideep

    2015-09-01

    Achieving stable fixation of displaced acute and chronic nonunited scaphoid fractures continues to be a challenge for the treating surgeon. The threaded compression screw has been the mainstay of treatment of these fractures for the last 3 decades; however, persistent nonunion after screw fixation has prompted development of new techniques. Recent results of volar buttress plating have been promising. We describe a novel technique of dorsal scaphoid plating. In contrast to volar plating, the dorsal plate is biomechanically more favorable as it utilizes the tension side of the scaphoid bone for dynamic compression. Dorsal scaphoid plating provides a more stable construct than the traditional Herbert screw and mitigates the need for vascular or corticocancellous bone grafting in most cases.

  7. Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

    PubMed

    Park, Jin-Woo; Kim, Kyoung-Tae; Sung, Joo-Kyung; Park, Seong-Hyun; Seong, Ki-Woong; Cho, Dae-Chul

    2017-09-01

    The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. The mean compression pressures of the 40- and 45-mm long cannulated lag screws were 50.48±1.20 N and 53.88±1.02 N, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was 52.82±2.17 N, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure (60.68±2.03 N) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

  8. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    PubMed

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  9. Biomechanical evaluation of a new composite bioresorbable screw.

    PubMed

    Bailey, C A; Kuiper, J H; Kelly, C P

    2006-04-01

    A new bioresorbable composite cannulated screw has been developed for small bone fracture fixation. The LG ("Little Grafter") screw is manufactured from Biosteon, which is a composite of poly L-lactic acid and hydroxyapatite. This study aimed to compare interfragmentary compression generated by this new screw with conventional metal screws commonly used in scaphoid fracture fixation. Four small metallic screws were compared with the LG screw, using a bone model produced from rigid polyurethane foam. The screws included the Acutrak, Asnis III, Herbert and Herbert-Whipple screws. The mean maximum compression forces for the LG screw, the Asnis and the Acutrak were comparable (LG 32.3 N, Asnis 32.8 N, Acutrak 38.3 N), whereas those using the Herbert and the Herbert-Whipple screw were significantly lower (Herbert 21.8 N, Herbert-Whipple 19.9 N). The bioresorbable LG screw has been shown to have good compressive properties compared to commonly used small bone fragment compression screws.

  10. A biomechanical evaluation of a cannulated compressive screw for use in fractures of the scaphoid.

    PubMed

    Rankin, G; Kuschner, S H; Orlando, C; McKellop, H; Brien, W W; Sherman, R

    1991-11-01

    The compressive force generated by a 3.5 mm ASIF cannulated cancellous screw with a 5 mm head was compared with that generated by a standard 3.5 mm ASIF screw (6 mm head), a 2.7 mm ASIF screw (5 mm head), and a Herbert screw. The screws were evaluated in the laboratory with the use of a custom-designed load washer (transducer) to the maximum compressive force generated by each screw until failure, either by thread stripping or by head migration into the specimen. Testing was done on paired cadaver scaphoids. To minimize the variability that occurs with human bone, and because of the cost and difficulty of obtaining human tissue specimens, a study was also done on polyurethane foam simulated bones. The 3.5 cannulated screw generated greater compressive forces than the Herbert screw but less compression than the 2.7 mm and 3.5 mm ASIF cortical screws. The 3.5 mm cannulated screw offers more rigid internal fixation for scaphoid fractures than the Herbert screw and gives the added advantage of placement over a guide wire.

  11. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    PubMed

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  12. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    PubMed

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that which can be obtained with 3 headless compression screws. Screw and external fixator performance did not correlate with bone mineral density. This study supports the use of external fixation as an alternative method of generating compression to help stimulate fusion across the transverse tarsal joints. The findings provide biomechanical evidence to support the use of external fixation as a viable option in transverse tarsal joint fusion cases in which screw fixation has failed or is anticipated to be inadequate due to suboptimal bone quality. © The Author(s) 2015.

  13. LagLoc - a new surgical technique for locking plate systems.

    PubMed

    Triana, Miguel; Gueorguiev, Boyko; Sommer, Christoph; Stoffel, Karl; Agarwal, Yash; Zderic, Ivan; Helfen, Tobias; Krieg, James C; Krause, Fabian; Knobe, Matthias; Richards, R Geoff; Lenz, Mark

    2018-06-19

    Treatment of oblique and spiral fractures remains challenging. The aim of this study was to introduce and investigate the new LagLoc technique for locked plating with generation of interfragmentary compression, combining the advantages of lag-screw and locking-head-screw techniques. Oblique fracture was simulated in artificial diaphyseal bones, assigned to three groups for plating with a 7-hole locking compression plate. Group I was plated with three locking screws in holes 1, 4 and 7. The central screw crossed the fracture line. In group II the central hole was occupied with a lag screw perpendicular to fracture line. Group III was instrumented applying the LagLoc technique as follows. Hole 4 was predrilled perpendicularly to the plate, followed by overdrilling of the near cortex and insertion of a locking screw whose head was covered by a holding sleeve to prevent temporarily the locking in the plate hole and generate interfragmentary compression. Subsequently, the screw head was released and locked in the plate hole. Holes 1 and 7 were occupied with locking screws. Interfragmentary compression in the fracture gap was measured using pressure sensors. All screws in the three groups were tightened with 4Nm torque. Interfragmentary compression in group I (167 ± 25N) was significantly lower in comparison to groups II (431 ± 21N) and III (379 ± 59N), p≤0.005. The difference in compression between groups II and III remained not significant (p = 0.999). The new LagLoc technique offers an alternative tool to generate interfragmentary compression with the application of locking plates by combining the biomechanical advantages of lag screw and locking screw fixations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Effect of interfragmentary gap on compression force in a headless compression screw used for scaphoid fixation.

    PubMed

    Tan, E S; Mat Jais, I S; Abdul Rahim, S; Tay, S C

    2018-01-01

    We investigated the effect of an interfragmentary gap on the final compression force using the Acutrak 2 Mini headless compression screw (length 26 mm) (Acumed, Hillsboro, OR, USA). Two blocks of solid rigid polyurethane foam in a custom jig were separated by spacers of varying thickness (1.0, 1.5, 2.0 and 2.5 mm) to simulate an interfragmentary gap. The spacers were removed before full insertion of the screw and the compression force was measured when the screw was buried 2 mm below the surface of the upper block. Gaps of 1.5 mm and 2.0 mm resulted in significantly decreased compression forces, whereas there was no significant decrease in compression force with a gap of 1 mm. An interfragmentary gap of 2.5 mm did not result in any contact between blocks. We conclude that an increased interfragmentary gap leads to decreased compression force with this screw, which may have implications on fracture healing.

  15. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S

    2007-12-01

    To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.

  16. Mechanical and structural characteristics of the new BONE-LOK cortical-cancellous internal fixation device.

    PubMed

    Cachia, Victor V; Culbert, Brad; Warren, Chris; Oka, Richard; Mahar, Andrew

    2003-01-01

    The purpose of this study was to evaluate the structural and mechanical characteristics of a new and unique titanium cortical-cancellous helical compression anchor with BONE-LOK (Triage Medical, Inc., Irvine, CA) technology for compressive internal fixation of fractures and osteotomies. This device provides fixation through the use of a distal helical anchor and a proximal retentive collar that are united by an axially movable pin (U.S. and international patents issued and pending). The helical compression anchor (2.7-mm diameter) was compared with 3.0-mm diameter titanium cancellous screws (Synthes, Paoli, PA) for pullout strength and compression in 7# and 12# synthetic rigid polyurethane foam (simulated bone matrix), and for 3-point bending stiffness. The following results (mean +/- standard deviation) were obtained: foam block pullout strength in 12# foam: 2.7-mm helical compression anchor 70 +/- 2.0 N and 3.0-mm titanium cancellous screws 37 +/- 11 N; in 7# foam: 2.7-mm helical compression anchor 33 +/- 3 N and 3.0-mm titanium cancellous screws 31 +/- 12 N. Three-point bending stiffness, 2.7-mm helical compression anchor 988 +/- 68 N/mm and 3.0-mm titanium cancellous screws 845 +/- 88 N/mm. Compression strength testing in 12# foam: 2.7-mm helical compression anchor 70.8 +/- 4.8 N and 3.0-mm titanium cancellous screws 23.0 +/- 3.1 N, in 7# foam: 2.7-mm helical compression anchor 42.6 +/- 3.2 N and 3.0-mm titanium cancellous screws 10.4 +/- 0.9 N. Results showed greater pullout strength, 3-point bending stiffness, and compression strength for the 2.7-mm helical compression anchor as compared with the 3.0-mm titanium cancellous screws in these testing models. This difference represents a distinct advantage in the new device that warrants further in vivo testing.

  17. Locking design affects the jamming of screws in locking plates.

    PubMed

    Sandriesser, Sabrina; Rupp, Markus; Greinwald, Markus; Heiss, Christian; Augat, Peter; Alt, Volker

    2018-06-01

    The seizing of locking screws is a frequently encountered clinical problem during implant removal of locking compression plates (LCP) after completion of fracture healing. The aim of this study was to investigate the effect of two different locking mechanisms on the seizing of locking screws. Specifically, the removal torques before and after cyclic dynamic loading were assessed for screws inserted at the manufacturer-recommended torque or at an increased insertion torque. The seizing of 3.5-mm angular stable screws was assessed as a function of insertion torque for two different locking mechanisms (Thread & Conus and Thread Only). Locking screws (n=10 for each configuration) were inserted either according to the manufacturer-recommended torque or at an increased torque of 150% to simulate an over-insertion of the screw. Half of the screws were removed directly after insertion and the remaining half was removed after a dynamic load protocol of 100,000 cycles. The removal torques of locking screws exceeded the insertion torques for all tested conditions confirming the adequacy of the test setup in mimicking screw seizing in locked plating. Screw seizing was more pronounced for Thread Only design (+37%) compared to Thread & Conus design (+14%; P<0.0001). Cyclic loading of the locking construct consistently resulted in an increased seizing of the locking screws (P<0.0001). Clinical observations from patients treated with the Thread & Conus locking design confirm the biomechanical findings of reduction in seizing effect by using a Thread & Conus design. In conclusion, both over-tightening and cyclic loading are potential causes for screw seizing in locking plate implants. Both effects were found to be less pronounced in the Thread & Conus design as compared to the traditional Thread Only design. © 2018 Elsevier Ltd. All rights reserved.

  18. Fracture Gap Reduction With Variable-Pitch Headless Screws.

    PubMed

    Roebke, Austin J; Roebke, Logan J; Goyal, Kanu S

    2018-04-01

    Fully threaded, variable-pitch, headless screws are used in many settings in surgery and have been extensively studied in this context, especially in regard to scaphoid fractures. However, it is not well understood how screw parameters such as diameter, length, and pitch variation, as well as technique parameters such as depth of drilling, affect gap closure. Acutrak 2 fully threaded variable-pitch headless screws of various diameters (Standard, Mini, and Micro) and lengths (16-28 mm) were inserted into polyurethane blocks of "normal" and "osteoporotic" bone model densities using a custom jig. Three drilling techniques (drill only through first block, 4 mm into second block, or completely through both blocks) were used. During screw insertion, fluoroscopic images were taken and later analyzed to measure gap reduction. The effect of backing the screw out after compression was evaluated. Drilling at least 4 mm past the fracture site reduces distal fragment push-off compared with drilling only through the proximal fragment. There were no significant differences in gap closure in the normal versus the osteoporotic model. The Micro screw had a smaller gap closure than both the Standard and the Mini screws. After block contact and compression with 2 subsequent full forward turns, backing the screw out by only 1 full turn resulted in gapping between the blocks. Intuitively, fully threaded headless variable-pitch screws can obtain compression between bone fragments only if the initial gap is less than the gap closed. Gap closure may be affected by drilling technique, screw size, and screw length. Fragment compression may be immediately lost if the screw is reversed. We describe characteristics of variable-pitch headless screws that may assist the surgeon in screw choice and method of use. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Screw Loosening and Pelvic Canal Narrowing After Lateral Plating of Feline Ilial Fractures With Locking and Nonlocking Plates.

    PubMed

    Schmierer, Philipp A; Kircher, Patrick R; Hartnack, Sonja; Knell, Sebastian C

    2015-10-01

    To compare the frequency of complications, including screw loosening and pelvic canal narrowing, associated with dynamic compression plating, locking plating, and double locking plating of ilial fractures in cats. Historical cohort study. The radiographs and medical records of cats with pelvic fractures that were presented between 2004 and 2013 were reviewed. The cases were categorized based on the plate type and number as dynamic compression plate (DCP), single locking plate (LPS) and double locking plates (dLPS). The frequency of screw loosening was compared across categories using a Fisher's exact test. The change in pelvic alignment, described by the change in sacral index (postoperative sacral index-followup sacral index), was compared across plate categories using ANOVA. The frequency of screw loosening for DCP (5/10) was significantly higher than LPS (1/13) and dLPS (0/11) (P = .05, P = .012, respectively). There was no significant difference in the SI change across plate categories. The mean change in sacral index for DCP was -0.11 (95%CI -0.25 to 0.03), for LPS was 0.0007 (95%CI -0.07 to 0.08), and for dLPS was -0.01 (95%CI -0.04 to 0.02). None of the cats showed constipation postoperatively. Screw loosening occurred less often but the change in pelvic canal alignment was not significantly different in ilial fractures repaired with LPS or dLPS compared to ilial fractures repaired with DCP. Locking plating of ilial fractures in cats may offer advantages compared to nonlocking plating. © Copyright 2015 by The American College of Veterinary Surgeons.

  20. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.

    PubMed

    Zachert, Gregor; Rapp, Marion; Eggert, Rebecca; Schulze-Hessing, Maaike; Gros, Nina; Stratmann, Christina; Wendlandt, Robert; Kaiser, Martin M

    2015-08-01

    For pediatric femoral shaft fractures, elastic stable intramedullary nailing (ESIN) is an accepted method of treatment. But problems regarding stability with shortening or axial deviation are well known in complex fracture types and heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with an additional tension screw fixation or screw fixation alone without nails could significantly improve the stability in comparison to classical ESIN. A total of 24 synthetic adolescent-sized femoral bone models (Sawbones, 4th generation; Vashon, Washington, United States) with an identical spiral fracture (length 100 mm) were used. All grafts underwent retrograde fixation with two C-shaped steel nails (2C). Of the 24, 8 osteosyntheses were supported by one additional tension screw (2C1S) and another 8 by two screws (2S) in which the intramedullary nails were removed before testing. Each configuration underwent biomechanical testing in 4-point bending, external rotation (ER) and internal rotation (IR). Furthermore, the modifications were tested in axial physiological 9 degrees position for shifting and dynamic compression as well as dynamic load. Both screw configurations (2C1S and 2S) demonstrated a significantly higher stability in comparison to the 2C configuration in 4-point bending (anterior-posterior, 0.95 Nm/mm [2C] < 8.41 Nm/mm [2C1S] and 15.12 Nm/mm [2S]; posterior-anterior, 8.55 Nm/mm [2C] < 12.65 Nm/mm [2C1S] and 17.54 Nm/mm [2S]; latero-medial, 1.17 Nm/mm [2C] < 5.53 Nm/mm [2C1S] and 9.15 Nm/mm [2S]; medio-lateral, 1.74 Nm/mm [2C] < 9.69 Nm/mm [2C1S] and 12.20 Nm [2S]; all p < 0.001) and during torsion (ER, 0.61 Nm/degree [2C] < 4.10 Nm/degree [2C1S] and 9.29 Nm/degree [2S]; IR, 0.18 Nm/degree [2C] < 6.17 Nm/degree [2C1S] and 10.61 Nm/degree [2S]; all p < 0.001]. The shifting in compression in 9 degrees position was only slightly influenced. The comparison of 2S versus 2C1S showed more stability for 2S than 2C1S in all testing, except the axial 9 degrees compression tests for shifting. In contrast to the 2C configuration, both modifications (2C1S and 2S) turned out to be stable in dynamic 9 degrees axial compression with a force of 100 up to 1,000 N at 2.5 Hz in 250,000 load cycles. In this in vitro adolescence femur spiral fracture model, the stability of ESIN could be significantly improved by two modifications with additional tension screws. If transferred in clinical practice, these modifications might offer earlier weight bearing and less problems of shortening or axial deviation. Georg Thieme Verlag KG Stuttgart · New York.

  1. Effects of abutment screw coating on implant preload.

    PubMed

    Park, Jae-Kyoung; Choi, Jin-Uk; Jeon, Young-Chan; Choi, Kyung-Soo; Jeong, Chang-Mo

    2010-08-01

    The aim of the present study was to investigate the effects of tungsten carbide carbon (WC/CTa) screw surface coating on abutment screw preload in three implant connection systems in comparison to noncoated titanium alloy (Ta) screws. Preload of WC/CTa abutment screws was compared to noncoated Ta screws in three implant connection systems. The differences in preloads were measured in tightening rotational angle, compression force, initial screw removal torque, and postload screw removal torque after 1 million cyclic loads. Preload loss percent was calculated to determine the efficacy of maintaining the preload of two abutment screw types in relation to implant connection systems. WC/CTa screws provided 10 degrees higher tightening rotational angle than Ta screws in all three connection systems. This difference was statistically significant (p < 0.05). External-hex butt joint implant connections had a higher compression force than the two internal conical implant connections. WC/CTa screws provided a statistically significantly higher compression force than Ta screws in all three implant connections (p < 0.05). Ta screws required statistically higher removal torque than WC/CTa screws in all three implant connections (p < 0.05); however, Ta screws needed statistically lower postload removal torque than WC/CTa screws in all three implant connections (p < 0.05). Ta screws had a statistically higher preload loss percent than WC/CTa screws in all three implant connections (p < 0.05), indicating that WC/CTa screws were superior in maintaining the preload than Ta screws. Within the limits of present study, the following conclusions were made: (1) WC/CTa screws provided higher preload than noncoated Ta screws in all three implant connection systems. (2) The initial removal torque for Ta screws required higher force than WC/CTa screws, whereas postload removal torque for Ta screws was lower than WC/CTa screws. Calculated Ta screw preload loss percent was higher than for WC/CTa screws, suggesting that WC/CTa screws were more effective in maintaining the preload than Ta screws. (3) Internal conical connections were more effective in maintaining the screw preload in cyclic loads than external-hex butt joint connections.

  2. Method for preventing jamming conditions in a compression device

    DOEpatents

    Williams, Paul M.; Faller, Kenneth M.; Bauer, Edward J.

    2002-06-18

    A compression device for feeding a waste material to a reactor includes a waste material feed assembly having a hopper, a supply tube and a compression tube. Each of the supply and compression tubes includes feed-inlet and feed-outlet ends. A feed-discharge valve assembly is located between the feed-outlet end of the compression tube and the reactor. A feed auger-screw extends axially in the supply tube between the feed-inlet and feed-outlet ends thereof. A compression auger-screw extends axially in the compression tube between the feed-inlet and feed-outlet ends thereof. The compression tube is sloped downwardly towards the reactor to drain fluid from the waste material to the reactor and is oriented at generally right angle to the supply tube such that the feed-outlet end of the supply tube is adjacent to the feed-inlet end of the compression tube. A programmable logic controller is provided for controlling the rotational speed of the feed and compression auger-screws for selectively varying the compression of the waste material and for overcoming jamming conditions within either the supply tube or the compression tube.

  3. [Dynamic forces of Mitkovic self-dinamysible trochanteric Internal fixators (SIF)].

    PubMed

    Mitković, Milan M; Manić, Miodrag T; Petković, Dusan Lj; Milenković, Sasa S; Mitković, Milorad B

    2013-01-01

    Dynamic trochanteric fractures implants allow fracture fragments to be compressed. Dynamisation can be realized if the axial pin force overcome friction force between pin and body of the implant. Examination of sliding iniciation forces in Mitkovic Selfdinamysible Trochanteric Internal Fixator (SIF). SIF was attached for angle block in the position with vertical orientation of pins. The transversal load of 5 kg was connected to pins by a rope. A dynamometer was used to measure force during the movement of angle block in up direction. Regression coefficients were a1 = 4,052 i b1 = 0,623 for SIF with 2 sliding screws with diameter of 7mm and a2 = 4,534 i b2 = 0,422 for SIF with 1 screw with diameter of 10 mm. Coefficients of determination were: r12 = 0,470 and r22 = 0,123. Sliding of SIF pins can be achieved for each analysed body weight of patient (50-130 kg). Early bearing of operated leg is significant for sliding initiation of SIF sliding screws.

  4. Evaluation of the effect of custom burr holes on a surgeon's sense of screw fixation in revision porous metal cups.

    PubMed

    Nyland, Mark A; Lanting, Brent A; Nikolov, Hristo N; Somerville, Lyndsay E; Teeter, Matthew G; Howard, James L

    2016-12-01

    It is common practice to burr custom holes in revision porous metal cups for screw insertion. The objective of this study was to determine how different hole types affect a surgeon's sense of screw fixation. Porous revision cups were prepared with pre-drilled and custom burred holes. Cups were held in place adjacent to synthetic bone material of varying density. Surgeons inserted screws through the different holes and materials. Surgeon subjective rating, compression, and torque was recorded. The torque achieved was greater ( p  = 0.002) for screws through custom holes than pre-fabricated holes in low and medium density material, with no difference for high density. Peak compression was greater ( p  = 0.026) through the pre-fabricated holes only in high density material. Use of burred holes affects the torque generated, and may decrease the amount of cup-acetabulum compression achieved.

  5. Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation.

    PubMed

    Kroeber, Markus W; Rovinsky, David; Haskell, Andrew; Heilmann, Moira; Llotz, Jeff; Otsuka, Norman

    2002-06-01

    This study compared cannulated 4.5-mm bioabsorbable screws made of self-reinforced poly-levolactic acid to cannulated 4.5-mm steel and titanium screws for resistance to shear stress and ability to generate compression in a polyurethane foam model of slipped capital femoral epiphysis fixation. The maximum shear stress resisted by the three screw types was similar (self-reinforced poly-levolactic acid 371 +/- 146 MPa, steel 442 +/- 43 MPa, and titanium 470 +/- 91 MPa). The maximum compression generated by both the self-reinforced poly-levolactic acid screw (68.5 +/- 3.3 N) and the steel screw (63.3 +/- 5.9 N) was greater than that for the titanium screw (3 +/- 1.4 N, P <.05). These data suggest cannulated self-reinforced poly-levolactic acid screws can be used in the treatment of slipped capital femoral epiphysis because of their sufficient biomechanical strength.

  6. A comparison of screw insertion torque and pullout strength.

    PubMed

    Ricci, William M; Tornetta, Paul; Petteys, Timothy; Gerlach, Darin; Cartner, Jacob; Walker, Zakiyyah; Russell, Thomas A

    2010-06-01

    Pullout strength of screws is a parameter used to evaluate plate screw fixation strength. However, screw fixation strength may be more closely related to its ability to generate sufficient insertion because stable nonlocked plate-screw fracture fixation requires sufficient compression between plate and bone such that no motion occurs between the plate and bone under physiological loads. Compression is generated by tightening of screws. In osteoporotic cancellous bone, sufficient screw insertion torque may not be generated before screw stripping. The effect of screw thread pitch on generation of maximum insertion torque (MIT) and pullout strength (POS) was investigated in an osteoporotic cancellous bone model and the relationship between MIT and POS was analyzed. Stainless steel screws with constant major (5.0 mm) and minor (2.7 mm) diameters but with varying thread pitches (1, 1.2, 1.5, 1.6, and 1.75 mm) were tested for MIT and POS in a validated osteoporotic surrogate for cancellous bone (density of 160 kg/m(3) [10 lbs/ft(3)]). MIT was measured with a torque-measuring hex driver for screws inserted through a one-third tubular plate. POS was measured after insertion of screws to a depth of 20 mm based on the Standard Specification and Test Methods for Metallic Medical Bone Screws (ASTM F 543-07). Five screws were tested for each failure mode and screw design. The relationship between MIT and compressive force between the plate and bone surrogate was evaluated using pressure-sensitive film. There was a significant difference in mean MIT based on screw pitch (P < 0.0001), whereas POS did not show statistically significant differences among the different screw pitches (P = 0.052). Small screw pitches (1.0 mm and 1.2 mm) had lower MIT and were distinguished from large pitches (1.5 mm, 1.6 mm, and the 1.75 mm) with higher MIT. For POS, only the 1-mm and 1.6-mm pitch screws were found to be different from each other. Linear regression analysis of MIT revealed a moderate correlation to the screw pitch (R(2) = 0.67, P < 0.0001), whereas the analysis of POS suggested no correlation to the screw pitch (R(2) = 0.28, P = 0.006). Pearson correlation analysis indicated no correlation between MIT and POS (P = 0.069, r = -0.37). A linear relationship of increased compression between the plate and bone surrogate was found for increasing screw torque (R(2) = 0.97). These results indicate that the ability of different screw designs to generate high screw insertion torque in a model of osteoporotic cancellous bone is unrelated to their pullout strength. Therefore, extrapolation of results for POS to identify optimal screw design for osteoporotic bone may not be valid. Screw designs that optimize MIT should be sought for fixation in osteoporotic bone.

  7. Compression device for feeding a waste material to a reactor

    DOEpatents

    Williams, Paul M.; Faller, Kenneth M.; Bauer, Edward J.

    2001-08-21

    A compression device for feeding a waste material to a reactor includes a waste material feed assembly having a hopper, a supply tube and a compression tube. Each of the supply and compression tubes includes feed-inlet and feed-outlet ends. A feed-discharge valve assembly is located between the feed-outlet end of the compression tube and the reactor. A feed auger-screw extends axially in the supply tube between the feed-inlet and feed-outlet ends thereof. A compression auger-screw extends axially in the compression tube between the feed-inlet and feed-outlet ends thereof. The compression tube is sloped downwardly towards the reactor to drain fluid from the waste material to the reactor and is oriented at generally right angle to the supply tube such that the feed-outlet end of the supply tube is adjacent to the feed-inlet end of the compression tube. A programmable logic controller is provided for controlling the rotational speed of the feed and compression auger-screws for selectively varying the compression of the waste material and for overcoming jamming conditions within either the supply tube or the compression tube.

  8. A clinical evaluation of alternative fixation techniques for medial malleolus fractures.

    PubMed

    Barnes, Hayley; Cannada, Lisa K; Watson, J Tracy

    2014-09-01

    Medial malleolus fractures have traditionally been managed using partially threaded screws and/or Kirschner wire fixation. Using these conventional techniques, a non-union rate of as high as 20% has been reported. In addition too many patients complaining of prominent hardware as a source of pain post-fixation. This study was designed to assess the outcomes of medial malleolar fixation using a headless compression screw in terms of union rate, the need for hardware removal, and pain over the hardware site. Saint Louis University and Mercy Medical Center, Level 1 Trauma Centers, St. Louis, MO. After IRB approval, we used billing records to identify all patients with ankle fractures involving the medial malleolus. Medical records and radiographs were reviewed to identify patients with medial malleolar fractures treated with headless compression screw fixation. Our inclusion criteria included follow-up until full weight bearing and a healed fracture. Follow-up clinical records and radiographs were reviewed to determine union, complication rate and perception of pain over the site of medial malleolus fixation. Sixty-four ankles were fixed via headless compression screws and 44 had adequate follow-up for additional evaluation. Seven patients had isolated medial malleolar fractures, 23 patients had bimalleolar fractures, and 14 patients had trimalleolar fractures. One patient (2%) required hardware removal due to cellulitis. One patient (2%) had a delayed union, which healed without additional intervention. Ten patients (23%) reported mild discomfort to palpation over the medial malleolus. The median follow-up was 35 weeks (range: 12-208 weeks). There were no screw removals for painful hardware and no cases of non-union. Headless compression screws provide effective compression of medial malleolus fractures and result in good clinical outcomes. The headless compression screw is a beneficial alternative to the conventional methods of medial malleolus fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Screw-Retaining Allen Wrench

    NASA Technical Reports Server (NTRS)

    Granett, D.

    1985-01-01

    Steadying screws with fingers unnecessary. Crimp in uncompressed spring wire slightly protrudes from one facet of Allen wrench. Compressed spring retains Allen screw. Tool used with Allen-head screws in cramped spaces with little or no room for fingers to hold fastener while turned by wrench.

  10. Comparison of the compressive strength of 3 different implant design systems.

    PubMed

    Pedroza, Jose E; Torrealba, Ysidora; Elias, Augusto; Psoter, Walter

    2007-01-01

    The aims of this study were twofold: to compare the static compressive strength at the implant-abutment interface of 3 design systems and to describe the implant abutment connection failure mode. A stainless steel holding device was designed to align the implants at 30 degrees with respect to the y-axis. Sixty-nine specimens were used, 23 for each system. A computer-controlled universal testing machine (MTS 810) applied static compression loading by a unidirectional vertical piston until failure. Specimens were evaluated macroscopically for longitudinal displacement, abutment looseness, and screw and implant fracture. Data were analyzed by analysis of variance (ANOVA). The mean compressive strength for the Unipost system was 392.5 psi (SD +/-40.9), for the Spline system 342.8 psi (SD+/-25.8), and for the Screw-Vent system 269.1 psi (SD+/-30.7). The Unipost implant-abutment connection demonstrated a statistically significant superior mechanical stability (P < or = .009) compared with the Spline implant system. The Spline implant system showed a statistically significant higher compressive strength than the Screw-Vent implant system (P < or =.009). Regarding failure mode, the Unipost system consistently broke at the same site, while the other systems failed at different points of the connection. The Unipost system demonstrated excellent fracture resistance to compressive forces; this resistance may be attributed primarily to the diameter of the abutment screw and the 2.5 mm counter bore, representing the same and a unique piece of the implant. The Unipost implant system demonstrated a statistically significant superior compressive strength value compared with the Spline and Screw-Vent systems, at a 30 degrees angulation.

  11. [Biomechanical properties of bioabsorbable cannulated screws for surgical fixation of dislocated epiphysiolysis capitis femoris].

    PubMed

    Kröber, M W; Rovinsky, D; Lotz, J; Carstens, C; Otsuka, N Y

    2002-06-01

    Bioabsorbable materials are well suited for fixation of slipped capital femoral epiphysis (SCFE) as they are resorbable, compatible with magnetic resonance imaging, and well tolerated by the pediatric population. We compared cannulated 4.5-mm bioabsorbable screws made of self-reinforced polylevolactic acid (SR-PLLA) to cannulated 4.5-mm steel and titanium screws for their resistance to shear stress and ability to generate compression in a polyurethane foam model of SCFE fixation. The maximum shear stress resisted by the three screw types was similar (SR-PLLA 371 +/- 146, steel 442 +/- 43, titanium 470 +/- 91 MPa, NS). The maximum compression generated by both the SR-PLLA screw (68.5 +/- 3.3 N) and the steel screw (63.3 +/- 5.9 N) was greater than that for the titanium screw (3.0 +/- 1.4 N, p < 0.05). These data suggest that cannulated SR-PLLA screws have sufficient biomechanical strength to be used in the treatment of SCFE.

  12. Controlling Rayleigh-Taylor Instabilities in Magnetically Driven Solid Metal Shells by Means of a Dynamic Screw Pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmit, P. F.; Velikovich, A. L.; McBride, R. D.

    Magnetically driven implosions of solid metal shells are an effective vehicle to compress materials to extreme pressures and densities. Rayleigh-Taylor instabilities (RTI) are ubiquitous, yet typically undesired features in all such experiments where solid materials are rapidly accelerated to high velocities. In cylindrical shells (“liners”), the magnetic field driving the implosion can exacerbate the RTI. Here, we suggest an approach to implode solid metal liners enabling a remarkable reduction in the growth of magnetized RTI (MRTI) by employing a magnetic drive with a tilted, dynamic polarization, forming a dynamic screw pinch. Our calculations, based on a self-consistent analytic framework, demonstratemore » that the cumulative growth of the most deleterious MRTI modes may be reduced by as much as 1 to 2 orders of magnitude. One key application of this technique is to generate increasingly stable, higher-performance implosions of solid metal liners to achieve fusion [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)]. Finally, we weigh the potentially dramatic benefits of the solid liner dynamic screw pinch against the experimental tradeoffs required to achieve the desired drive field history and identify promising designs for future experimental and computational studies.« less

  13. Controlling Rayleigh-Taylor Instabilities in Magnetically Driven Solid Metal Shells by Means of a Dynamic Screw Pinch

    DOE PAGES

    Schmit, P. F.; Velikovich, A. L.; McBride, R. D.; ...

    2016-11-11

    Magnetically driven implosions of solid metal shells are an effective vehicle to compress materials to extreme pressures and densities. Rayleigh-Taylor instabilities (RTI) are ubiquitous, yet typically undesired features in all such experiments where solid materials are rapidly accelerated to high velocities. In cylindrical shells (“liners”), the magnetic field driving the implosion can exacerbate the RTI. Here, we suggest an approach to implode solid metal liners enabling a remarkable reduction in the growth of magnetized RTI (MRTI) by employing a magnetic drive with a tilted, dynamic polarization, forming a dynamic screw pinch. Our calculations, based on a self-consistent analytic framework, demonstratemore » that the cumulative growth of the most deleterious MRTI modes may be reduced by as much as 1 to 2 orders of magnitude. One key application of this technique is to generate increasingly stable, higher-performance implosions of solid metal liners to achieve fusion [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)]. Finally, we weigh the potentially dramatic benefits of the solid liner dynamic screw pinch against the experimental tradeoffs required to achieve the desired drive field history and identify promising designs for future experimental and computational studies.« less

  14. Stress analysis of implant-bone fixation at different fracture angle

    NASA Astrophysics Data System (ADS)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  15. Mechanical characteristics of the new BONE-LOK bi-cortical internal fixation device.

    PubMed

    Cachia, Victor V; Shumway, Don; Culbert, Brad; Padget, Marty

    2003-01-01

    The purpose of this study was to evaluate the mechanical characteristics of a new and unique titanium compression anchor with BONE-LOK (Triage Medical, Inc, Irvine, CA) technology for compressive, bi-cortical internal fixation of bone. This device provides fixation through the use of a distal grasping anchor and an adjustable proximal collar that are joined by an axially movable pin and guide wire. The titanium compression anchor, in 2.0-, 2.7-, and 3.5-mm diameters, were compared with cortex screws (Synthes USA, Paoli, PA) of the same diameter and material for pullout strength in 20 lb/cu ft and 30 lb/cu ft solid rigid polyurethane foam; and for compression strength in 20 lb/cu ft foam. Retention strength of the collar was tested independently. The results showed significantly greater pullout strength of the 2.7-mm and 3.5-mm titanium compression anchor as compared with the 2.7-mm and 3.5-mm cortex screws in these test models. Pullout strength of the 2.0-mm titanium compression anchor was not statistically different in comparison with the 2.0-mm cortical screws. Compression strength of the titanium compression anchor was significantly greater than the cortical screws for all diameters tested. These differences represent a distinct advantage with the new device, which warrants further in vivo testing. Collar retention strength testing values were obtained for reference only and have no comparative significance.

  16. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    PubMed

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  17. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    PubMed

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Removal of a broken trigen intertan intertrochanteric antegrade nail.

    PubMed

    Zheng, Xuan-Lin; Park, Young-Chang; Kim, Sungmin; An, Haemosu; Yang, Kyu-Hyun

    2017-02-01

    Implant breakage is a serious complication after cephalomedullary nailing for unstable intertrochanteric fracture. Failure usually occurs at the lag screw hole in the nail body. On the other hand, lag screw failure is extremely rare and occurs around the nail-lag screw junction. We experienced rare mechanical failure of the Intertan nail, which showed breakage at the lag screw hole and failure of the integrated compression screw underneath the main lag screw. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.

    PubMed

    Karaarslan, A A; Acar, N

    2018-02-01

    Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.

  20. [APPLICATION OF COMPRESSION MINI-SCREWS IN TREATMENT OF PATIENTS WITH INJURY OF ELBOW JOINT BONES].

    PubMed

    Neverov, V A; Egorov, K S

    2015-01-01

    A case report presents the experience of application of compression pileateless mini-screws (Gerbert's screws) in treatment of intra-articular fractures, which formed the elbow joint (44 cases). There were performed 32 operations concerning fracture of head of radius, 10 operations on the occasion of fractures of distal section of the humerus and 2 operations on the coronoid process. Long-term treatment results were followed-up in 31 patients during more than 6 months. On basis of analysis of treatment results the authors made a conclusion that the application of mini-screws in case of bone fractures, which formed the elbow joint, allowed realization of stable osteosynthesis after anatomic reposition of articular surfaces, obtaining good anatomical and functional result and shortened the terms of patient's treatment.

  1. Biomechanical characteristics of fixation methods for floating pubic symphysis.

    PubMed

    Song, Wenhao; Zhou, Dongsheng; He, Yu

    2017-03-07

    Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.

  2. Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate.

    PubMed

    Nelson, Thomas A; Strom, Adam

    2017-11-01

    Objectives  Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Methods  Electronic medical records from one specialty referral centre were reviewed from March 21, 2010, to October 9, 2015, for patients weighing less than or equal to 4 kg that had a distal one-third radial and ulnar fracture repaired with a Synthes 1.5-mm locking adaption plate or Synthes 2.0-mm LC-DCP. Further inclusion criteria included application of the plate to the cranial surface of the radius via open reduction and internal fixation. Results  Six 1.5-mm Adaption plates and 7 2.0-mm LC-DCPs were used to repair 13 distal radial and ulnar fractures in 12 dogs. There were three major complications in the 1.5-mm adaption plate group (one plate fracture, one screw pull-out and one fracture through a distal screw hole) and one major complication in the 2.0-mm LC-DCP group due to a re-fracture. All patients without a complication had good or excellent functional outcome. Clinical Significance  The authors recommend that the 1.5-mm Adaption plate be used only when a 2.0-mm LC-DCP would not allow for a minimum of two screws in the distal segment and at the discretion of the surgeon. Schattauer GmbH Stuttgart.

  3. A miniature Rotary Compressor with a 1:10 compression ratio

    NASA Astrophysics Data System (ADS)

    Dmitriev, Olly; Tabota, Eugene; Arbon EurIng, Ian; FIMechE, CEng

    2015-08-01

    Micro compressors have applications in medical devices, robotics and “nanosatellites”. The problem of active cooling for photo detectors in “nano-satellites” becomes more important because the majority of space missions target Earth observation, and passive cooling does not provide the required temperatures to achieve the desired SNR levels. Reciprocating compressors used in cryocoolers cause vibrations. VERT Rotors has built an ultralow-vibration rotary compressor with 40mm-long screws, and our prototype delivered 1:10 compression ratio. This “nano” compressor is a non-conventional conical type consisting of an Inner conical screw rotor revolving inside an Outer screw rotor.

  4. Hip fracture - discharge

    MedlinePlus

    ... or a special metal plate or rod with screws, called compression screws or nails, put in place. Alternatively, you may ... walking as soon as possible. For this reason, it is very important to stay active and follow ...

  5. Biomechanical testing of locking and nonlocking plates in the canine scapula.

    PubMed

    Acquaviva, Anthony E; Miller, Emily I; Eisenmann, David J; Stone, Rick T; Kraus, Karl H

    2012-01-01

    Locking plates have been shown to offer improved fixation in fractures involving either osteoporotic bone or bone with lesser screw pullout strength, such as thin and flat bones. Fractures of the scapular body are one type of fracture where the screw pullout strength using conventional plate fixation may not be sufficient to overcome physiologic forces. The purpose of this study was to compare the pullout strengths of locking plates to conventional nonlocking plates in the canine scapula. A 2.7 mm string of pearls plate (SOP) and a 2.7 mm limited contact dynamic compression plate (LC-DCP) were applied with similar divergent screws to the supraspinatus fossa of the scapula. Forces perpendicular to the plates were applied and both the loads at failure and modes of failure were recorded. No differences were noted in loads at failure between the two plating systems. Although the modes of failure were not significantly different, the SOP constructs tended to fail more often by bone slicing and coring, whereas the LC-DCP constructs failed primarily by screw stripping. Neither of the plate systems used in this study demonstrated a distinct mechanical advantage. The application and limitations of locking plate systems in various clinical situations require further study.

  6. Preliminary Design on Screw Press Model of Palm Oil Extraction Machine

    NASA Astrophysics Data System (ADS)

    Firdaus, Muhammad; Salleh, S. M.; Nawi, I.; Ngali, Z.; Siswanto, W. A.; Yusup, E. M.

    2017-01-01

    The concept of the screw press is to compress the fruit bunch between the main screw and travelling cones to extract the palm oil. Visual inspection, model development and simulation of screw press by using Solidworks 2016 and calculation of design properties were performed to support the investigation. The project aims to analyse different design of screw press which improves in reducing maintenance cost and increasing lifespan. The currently existing of screw press can endure between 500 to 900 hours and requires frequent maintenance. Different configurations have been tried in determination of best design properties in screw press. The results specify that screw press with tapered inner shaft has more total lifespan (hours) compared existing screw press. The selection of the screw press with tapered inner shaft can reduce maintenance cost and increase lifespan of the screw press.

  7. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.

    PubMed

    Bulaqi, Haddad Arabi; Mousavi Mashhadi, Mahmoud; Safari, Hamed; Samandari, Mohammad Mahdi; Geramipanah, Farideh

    2015-06-01

    Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening. The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant bone and evaluate the effect of increased crown height space (CHS) and crown-to-implant ratio on stress concentrations under external oblique forces. The severely resorbed bone of a posterior mandible site was modeled with Mimics and Catia software. A second mandibular premolar tooth was modeled with CHS values of 8.8, 11.2, 13.6, and 16 mm. A Straumann implant (4.1×8 mm), a directly attached crown, and an abutment screw were modeled with geometric data and designed by using SolidWorks software. Abaqus software was used for the dynamic simulation of screw tightening and the application of an external load to the buccal cusp at a 75.8-degree angle with the occlusal plane. The distribution of screw load and member load at each step was compared, and the stress values were calculated within the dental implant complex and surrounding bone. During tightening, the magnitude and distribution of the preload and clamp load were uniform and equal at the cross section of all CHSs. Under an external load, the screw load decreased and member load increased. An increase in the CHS caused the corresponding distribution to become more nonuniform and increased the maximum compressive and tensile stresses in the preimplant bone. Additionally, the von Mises stress decreased at the abutment screw and increased at the abutment and fixture. Under nonaxial forces, increased CHS does not influence the decrease in screw load or increase in member load. However, it contributes to screw loosening and fatigue fracture by skewing the stress distribution to the transverse section of the implant. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. CFD simulation of a screw compressor including leakage flows and rotor heating

    NASA Astrophysics Data System (ADS)

    Spille-Kohoff, Andreas, Dr.; Hesse, Jan; El Shorbagy, Ahmed

    2015-08-01

    Computational Fluid Dynamics (CFD) simulations have promising potential to become an important part in the development process of positive displacement (PD) machines. CFD delivers deep insights into the flow and thermodynamic behaviour of PD machines. However, the numerical simulation of such machines is more complex compared to dynamic pumps like turbines or fans. The fluid transport in size-changing chambers with very small clearances between the rotors, and between rotors and casing, demands complex meshes that change with each time step. Additionally, the losses due to leakage flows and the heat transfer to the rotors need high-quality meshes so that automatic remeshing is almost impossible. In this paper, setup steps and results for the simulation of a dry screw compressor are shown. The rotating parts are meshed with TwinMesh, a special hexahedral meshing program for gear pumps, gerotors, lobe pumps and screw compressors. In particular, these meshes include axial and radial clearances between housing and rotors, and beside the fluid volume the rotor solids are also meshed. The CFD simulation accounts for gas flow with compressibility and turbulence effects, heat transfer between gas and rotors, and leakage flows through the clearances. We show time- resolved results for torques, forces, interlobe pressure, mass flow, and heat flow between gas and rotors, as well as time- and space-resolved results for pressure, velocity, temperature etc. for different discharge ports and working points of the screw compressor. These results are also used as thermal loads for deformation simulations of the rotors.

  9. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    PubMed

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  10. Increasing Lift by Releasing Compressed Air on Suction Side of Airfoil

    NASA Technical Reports Server (NTRS)

    Seewald, F

    1927-01-01

    The investigation was limited chiefly to the region of high angles of attack since it is only in this region that any considerable change in the character of the flow can be expected from such artificial aids. The slot, through which compressed air was blown, was formed by two pieces of sheet steel connected by screws at intervals of about 5 cm. It was intended to regulate the width of the slot by means of these screws. Much more compressed air was required than was originally supposed, hence all the delivery pipes were much too small. This experiment, therefore, is to be regarded as only a preliminary one.

  11. Biomechanical demands on posterior fusion instrumentation during lordosis restoration procedures.

    PubMed

    Kuo, Calvin C; Martin, Audrey; Telles, Connor; Leasure, Jeremi; Iezza, Alex; Ames, Christopher; Kondrashov, Dimitriy

    2016-09-01

    OBJECTIVE The goal of this study was to investigate the forces placed on posterior fusion instrumentation by 3 commonly used intraoperative techniques to restore lumbar lordosis: 1) cantilever bending; 2) in situ bending; and 3) compression and/or distraction of screws along posterior fusion rods. METHODS Five cadaveric torsos were instrumented with pedicle screws at the L1-5 levels. Specimens underwent each of the 3 lordosis restoration procedures. The pedicle screw pullout force was monitored in real time via strain gauges that were mounted unilaterally at each level. The degree of correction was noted through fluoroscopic imaging. The peak loads experienced on the screws during surgery, total demand on instrumentation, and resting loads after corrective maneuvers were measured. RESULTS A mean overall lordotic correction of 10.9 ± 4.7° was achieved. No statistically significant difference in lordotic correction was observed between restoration procedures. In situ bending imparted the largest loads intraoperatively with an average of 1060 ± 599.9 N, followed by compression/distraction (971 ± 534.1 N) and cantilever bending (705 ± 413.0 N). In situ bending produced the largest total demand and postoperative loads at L-1 (1879 ± 1064.1 and 487 ± 118.8 N, respectively), which were statistically higher than cantilever bending and compression/distraction (786 ± 272.1 and 138 ± 99.2 N, respectively). CONCLUSIONS In situ bending resulted in the highest mechanical demand on posterior lumbar instrumentation, as well as the largest postoperative loads at L-1. These results suggest that the forces generated with in situ bending indicate a greater chance of intraoperative instrumentation failure and postoperative proximal pedicle screw pullout when compared with cantilever bending and/or compression/distraction options. The results are aimed at optimizing correction and fusion strategies in lordosis restoration cases.

  12. MD modeling of screw dislocation influence upon initiation and mechanism of BCC-HCP polymorphous transition in iron

    NASA Astrophysics Data System (ADS)

    Dremov, V. V.; Ionov, G. V.; Sapozhnikov, F. A.; Smirnov, N. A.; Karavaev, A. V.; Vorobyova, M. A.; Ryzhkov, M. V.

    2015-09-01

    The present work is devoted to classical molecular dynamics investigation into microscopic mechanisms of the bcc-hcp transition in iron. The interatomic potential of EAM type used in the calculations was tested for the capability to reproduce ab initio data on energy evolution along the bcc-hcp transformation path (Burgers deformation + shuffe) and then used in the large-scale MD simulations. The large-scale simulations included constant volume deformation along the Burgers path to study the origin and nature of the plasticity, hydrostatic volume compression of defect free samples above the bcc to hcp transition threshold to observe the formation of new phase embryos, and the volume compression of samples containing screw dislocations to study the effect of the dislocations on the probability of the new phase critical embryo formation. The volume compression demonstrated high level of metastability. The transition starts at pressure much higher than the equilibrium one. Dislocations strongly affect the probability of the critical embryo formation and significantly reduce the onset pressure of transition. The dislocations affect also the resulting structure of the samples upon the transition. The formation of layered structure is typical for the samples containing the dislocations. The results of the simulations were compared with the in-situ experimental data on the mechanism of the bcc-hcp transition in iron.

  13. Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.

    PubMed

    Wu, P H; Shen, L; Chee, Y H

    2016-04-01

    To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union with fewer complications.

  14. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    PubMed

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p

  15. Use of intramedullary fibular strut graft: a novel adjunct to plating in the treatment of osteoporotic humeral shaft nonunion

    PubMed Central

    Vamsi, K.; Rao, Sharath K.; Gnanadoss, James J.; Pandian, S.

    2008-01-01

    Humeral shaft fractures respond well to conservative treatment and unite without much problem. Since it is uncommon, there is not much discussion regarding the management of nonunion in the literature, and hence this is a challenge to the treating orthopaedic surgeon. Osteoporosis of the fractured bone and stiffness of the surrounding joints compounds the situation further. The Ilizarov fixator, locking compression plate, and vascularised fibular graft are viable options in this scenario but are technically demanding. We used a fibular strut graft for bridging the fracture site in order to enhance the pull-out strength of the screws of the dynamic compression plate. Six patients in the study had successful uneventful union of the fracture at the last follow-up. The fibula is easy to harvest and produces less graft site morbidity. None of the study patients needed additional iliac crest bone grafting. This is the largest reported series of patients with osteoporotic atrophic nonunion of humerus successfully treated solely using the combination of an intramedullary fibular strut graft and dynamic compression plate. PMID:18563410

  16. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    Jacketed metal bodies of the type used as fuel elements for nuclear reactors, which contain an internal elongated body of fissionable material jacketed in a corrosion resistant metal are described. The ends of the internal bodies are provided with screw threads having a tapered outer end. The jacket material overlaps the ends and extends into the tapered section of the screw threaded opening. Screw caps with a mating tapered section are screwed into the ends of the body to compress the jacket material in the tapered sections to provtde an effective seal against corrosive gases and liquids.

  17. A convenient dynamic loading device for studying kinetics of phase transitions and metastable phases using symmetric diamond anvil cells

    NASA Astrophysics Data System (ADS)

    Cheng, Hu; Zhang, Junran; Li, Yanchun; Li, Gong; Li, Xiaodong; Liu, Jing

    2018-01-01

    We have designed and implemented a novel DLD for controlling pressure and compression/decompression rate. Combined with the use of the symmetric diamond anvil cells (DACs), the DLD adopts three piezo-electric (PE) actuators and three static load screws to remotely control pressure in accurate and consistent manner at room temperature. This device allows us to create different loading mechanisms and frames for a variety of existing and commonly used diamond cells rather than designing specialized or dedicated diamond cells with various drives. The sample pressure compression/decompression rate that we have achieved is up to 58.6/43.3 TPa/s, respectively. The minimum of load time is less than 1 ms. The DLD is a powerful tool for exploring the effects of rapid (de)compression on the structure of materials and the properties of materials.

  18. The Role of Posterior Screw Fixation in Single-Level Transforaminal Lumbar Interbody Fusion During Whole Body Vibration: A Finite Element Study.

    PubMed

    Fan, Wei; Guo, Li-Xin

    2018-06-01

    Few studies have evaluated the need for supplementary instrumentation after lumbar interbody fusion under the condition of whole body vibration (WBV) that is typically present in vehicles. This study aimed to determine the effect of posterior pedicle screw fixation on dynamic response of the whole lumbar spine to vertical WBV after transforaminal lumbar interbody fusion (TLIF). A previously validated nonlinear, osteoligamentous finite element (FE) model of the intact L1-sacrum human lumbar spine was modified to simulate single-level (L4-L5) TLIF without and with bilateral pedicle screw fixation (BPSF). Transit dynamic analysis was performed on the 2 developed models under a sinusoidal vertical vibration load of ±40 N and a compressive follower preload of 400 N. The resulting dynamic response results for the 2 models in terms of stresses and deformations were recorded and compared. When compared with no fixation, BPSF decreased dynamic responses of the spinal levels to the vertical vibration after TLIF. At the fused level (L4-L5), vibration amplitudes of the von-Mises stresses in L4 inferior endplate and L5 superior endplate decreased after BPSF by 48.0% and 46.4%, respectively. At other disc levels (L1-L2, L2-L3, L3-L4, and L5-S1), vibration amplitudes of the disc bulge, von-Mises stress in annulus ground substance and intradiscal pressure also produced 4.2%-9.0%, 2.3%-8.9%, and 3.4%-8.8% deceases, respectively, after BPSF. After TLIF, application of BPSF can be helpful in the prevention of spine injury during vertical WBV. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Air-Lubricated Lead Screw

    NASA Technical Reports Server (NTRS)

    Perkins, G. S.

    1983-01-01

    Air lubricated lead screw and nut carefully machined to have closely matched closely fitting threads. Compressed air injected into two plenums encircle nut and flow through orifices to lubricate mating threads. Originally developed to position precisely interferometer retroreflector for airborne measurement of solar infrared radiation, device now has positioning accuracy of 0.25 micron.

  20. Retrospective analysis of factors associated with outcome of proximal interphalangeal joint arthrodesis in 82 horses including Warmblood and Thoroughbred sport horses and Quarter Horses (1992-2014).

    PubMed

    Herthel, T D; Rick, M C; Judy, C E; Cohen, N D; Herthel, D J

    2016-09-01

    Outcomes associated with arthrodesis of the proximal interphalangeal (PIP) joint in Quarter Horses used for Western performance activities are well documented but little is known regarding outcomes for other types of horses. To identify factors associated with outcomes, including breed and activity, after arthrodesis of the PIP joint in Warmbloods, Thoroughbreds and Quarter Horses. Retrospective case series. Surgical case records of 82 Quarter Horses principally engaged in Western performance and Thoroughbred or Warmblood breeds principally engaged in showing, showjumping and dressage, with arthrodesis of the PIP joint were reviewed. Arthrodesis was performed with either 3 transarticular cortex bone screws placed in lag fashion, a dynamic compression plate (DCP) with 2 transarticular cortex bone screws placed in lag fashion, or a locking compression plate (LCP) with 2 transarticular cortex bone screws placed in lag fashion. Demographic data, clinical presentation, radiographic findings, surgical technique, post operative treatment and complications were recorded. Long-term follow-up was obtained for all 82 horses. Osteoarthritis of the PIP joint was the most common presenting condition requiring arthrodesis, which was performed with either the 3 screw technique (n = 41), DCP fixation (n = 22), or LCP fixation (n = 19). Post operatively, 23/31 (74%) Warmbloods/Thoroughbreds and 44/51 (87%) Quarter Horses achieved successful outcomes. Thirteen of 23 (57%) Warmbloods/Thoroughbreds and 24 of 38 (63%) Quarter Horses, used for athletic performance, returned to successful competition. Within this subgroup of horses engaged in high-level activity, regardless of breed type, horses undergoing hindlimb arthrodesis were significantly more likely to return to successful competition (73%; 33/45) than those with forelimb arthrodesis (25%; 4/16, P = 0.002). Arthrodesis of the PIP joint in Warmbloods/Thoroughbreds and Quarter Horses results in a favourable outcome for return to their intended use and athletic competition. © 2015 EVJ Ltd.

  1. Critical bending moment of four implant-abutment interface designs.

    PubMed

    Lee, Frank K; Tan, Keson B; Nicholls, Jack I

    2010-01-01

    Critical bending moment (CBM), defined as the bending moment at which the external nonaxial load applied overcomes screw joint preload and causes loss of contact between the mating surfaces of the implant screw joint components, was measured for four different implants and their single-tooth replacement abutments. CBM at the implant-abutment screw joint for four implant-abutment test groups was measured in vitro at 80%, 100%, and 120% of the manufacturers' recommended torque levels. Regular-platform implants with their corresponding single-tooth abutments were used. Microstrain was measured while known loads were applied to the abutment at known distances from the implant-abutment interface. Strain instrumentation was used to record the strain data dynamically to determine the point of gap opening. All torque applications and strain measurements were repeated five times for the five samples in each group. For the Branemark/CeraOne assemblies, the mean CBMs were 72.14 Ncm, 102.21 Ncm, and 119.13 Ncm, respectively, at 80%, 100%, and 120% of the manufacturer's recommended torque. For the Replace/Easy assemblies, mean CBMs were 86.20 Ncm, 109.92 Ncm, and 120.93 Ncm; for the Biomet 3i/STA assemblies, they were 67.97 Ncm, 83.14 Ncm, and 91.81 Ncm; and for the Lifecore/COC assemblies, they were 58.32 Ncm, 76.79 Ncm, and 78.93 Ncm. Two-way analysis of variance revealed significant effects for the test groups and torque levels. Subsequent tests confirmed that significant differences existed between test groups and torque levels. The results appear to confirm the primary role of the compressive preload imparted by the abutment screw in maintaining screw joint integrity. CBM was found to differ among implant systems and torque levels. Torque levels recommended by the manufacturer should be followed to ensure screw joint integrity.

  2. The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.

    PubMed

    Liu, Jia-Ming; Zhang, Yu; Zhou, Yang; Chen, Xuan-Yin; Huang, Shan-Hu; Hua, Zi-Kai; Liu, Zhi-Li

    2017-06-01

    Posterior reduction and pedicle screw fixation is a widely used procedure for thoracic and lumbar vertebrae fractures. Usually, the pedicle screws would be removed after the fracture healing and screw tunnels would be left. The aim of this study is to evaluate the effect of screw tunnels on the biomechanical stability of the lumbar vertebral body after pedicle screws removal by finite element analysis (FEA). First, the CT values of the screw tunnels wall in the fractured vertebral bodies were measured in patients whose pedicle screws were removed, and they were then compared with the values of vertebral cortical bone. Second, an adult patient was included and the CT images of the lumbar spine were harvested. Three dimensional finite element models of the L1 vertebra with unilateral or bilateral screw tunnels were created based on the CT images. Different compressive loads were vertically acted on the models. The maximum loads which the models sustained and the distribution of the force in the different parts of the models were recorded and compared with each other. The CT values of the tunnels wall and vertebral cortical bone were 387.126±62.342 and 399.204±53.612, which were not statistically different (P=0.149). The models of three dimensional tetrahedral mesh finite element of normal lumbar 1 vertebra were established with good geometric similarity and realistic appearance. After given the compressive loads, the cortical bone was the first one to reach its ultimate stress. The maximum loads which the bilateral screw tunnels model, unilateral screw tunnel model, and normal vertebral model can sustain were 3.97 Mpa, 3.83 Mpa, and 3.78 Mpa, respectively. For the diameter of the screw tunnels, the model with a diameter of 6.5 mm could sustain the largest load. In addition, the stress distributing on the outside of the cortical bone gradually decreased as the thickness of the tunnel wall increased. Based on the FEA, pedicle screw tunnels would not decrease the biomechanical stability and strength of the vertebral body. A large diameter of screw tunnel and thick tunnel wall were helpful for the biomechanical stability of the vertebral body.

  3. Reconstruction of the lateral tibia plateau fracture with a third triangular support screw: A biomechanical study.

    PubMed

    Moran, Eduardo; Zderic, Ivan; Klos, Kajetan; Simons, Paul; Triana, Miguel; Richards, R Geoff; Gueorguiev, Boyko; Lenz, Mark

    2017-10-01

    Split fractures of the lateral tibia plateau in young patients with good bone quality are commonly treated using two minimally invasive percutaneous lag screws, followed by unloading of the knee joint. Improved stability could be achieved with the use of a third screw inserted either in the jail-technique fashion or with a triangular support screw configuration. The aim of this study was to investigate under cyclic loading the compliance and endurance of the triangular support fixation in comparison with the standard two lag-screw fixation and the jail technique. Lateral split fractures of type AO/OTA 41-B1 were created on 21 synthetic tibiae and subsequently fixed with one of the following three techniques for seven specimens: standard fixation by inserting two partially threaded 6.5 mm cannulated lag screws parallel to each other and orthogonal to the fracture plane; triangular support fixation-standard fixation with one additional support screw at the distal end of the fracture at 30° proximal inclination; and jail fixation-standard fixation with one additional orthogonal support screw inserted in the medial nonfractured part of the bone. Mechanical testing was performed under progressively increasing cyclic compression loading. Fragment displacement was registered via triggered radiographic imaging. Mean construct compliance was 3.847 × 10 -3  mm/N [standard deviation (SD) 0.784] for standard fixation, 3.838 × 10 -3  mm/N (SD 0.242) for triangular fixation, and 3.563 × 10 -3  mm/N (SD 0.383) for jail fixation, with no significant differences between the groups ( p  = 0.525). The mean numbers of cycles to 2 mm fragment dislocation, defined as a failure criterion, were 12,384 (SD 2267) for standard fixation, 17,708 (SD 2193) for triangular fixation, and 14,629 (SD 5194) for jail fixation. Triangular fixation revealed significantly longer endurance than the standard one ( p  = 0.047). Triangular support fixation enhanced interfragmentary stability at the ultimate stage of dynamic loading. However, the level of improvement seems to be limited and may not legitimate the intervention with an additional third screw.

  4. Effect of formulation and process variables on lipid based sustained release tablets via continuous twin screw granulation: A comparative study.

    PubMed

    Kallakunta, Venkata Raman; Tiwari, Roshan; Sarabu, Sandeep; Bandari, Suresh; Repka, Michael A

    2018-05-14

    The current study's aim is to prepare lipid based sustained release tablets via a twin-screw granulation technique and compare those dosage forms with conventional techniques, namely wet granulation and direct compression. The granules were successfully manufactured in a single-step, continuous twin-screw granulation process with a low proportion of binder (Klucel™ EF, HPC SSL) using Compritol® 888 ATO, Precirol® ATO 5 and Geleol™ as sustained release agents. The granules prepared showed good flow characteristics and compaction properties. DSC and XRD studies were conducted to characterize the granules prepared via a twin-screw granulation method and the results demonstrated the crystalline nature of lipids within the granules. FTIR data indicated that there were no interactions with the formulation components investigated. The formulations developed by all three methods were compressed into tablets with a mechanical strength of 14-16 KP. The tablets formulated were characterized for physicochemical properties, in vitro drug release studies, water uptake and erosion studies. These results showed that the drug was not completely released after 24 h for tablets developed by the wet granulation process using all three lipids. The tablets prepared by the direct compression method demonstrated a burst release within 8 to 10 h from Precirol ATO 5® and Geleol™ formulations compared to Compritol® 888 ATO. However, tablets prepared using twin-screw granulation exhibited sustained release of the drug over 24 h and the water uptake and erosion results were in accordance with dissolution data. Stability data for 45 days at accelerated conditions (40 °C/75% RH) showed similar release profiles with ƒ2 values above 50 for all of the twin screw granulation formulations, indicating the suitability of the process for formulating sustained release tablets. These findings of a single-step, continuous twin-screw granulation process are novel and demonstrate new opportunities for development of sustained release tablets. Copyright © 2017. Published by Elsevier B.V.

  5. Actively suspended counter-rotating machine

    NASA Technical Reports Server (NTRS)

    Studer, Philip A. (Inventor)

    1983-01-01

    A counter-rotating machine, such as a positive displacement pump having a pair of meshed, non-contacting helical screws (10,12), subjects its rotating members to axial and radial thrust forces when used for such purposes as compression of liquid or gaseous phase fluids while transporting them through a pump cavity (11,13). Each helical screw (10,12) has a shaft (17,17') which is actively suspended at opposite ends (11a,11b) of the pump cavity by a servo-controlled magnetic bearing assembly (19) and a servo-controlled rotary drive motor (20). Both bearing assemblies and drive motors are mounted on the outside of the pump cavity (11,13). Opto-electric angular position sensors (250) provide synchronization between radial orientation of the drive motors. The bearing assemblies and drive motors conjugately provide axial stabilization and radial centering of the helical screws during volumetric compression of aspirated liquid or gaseous phase fluids.

  6. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out.

    PubMed

    Pujari-Palmer, Michael; Robo, Celine; Persson, Cecilia; Procter, Philip; Engqvist, Håkan

    2018-01-01

    Disease and injuries that affect the skeletal system may require surgical intervention and internal fixation, i.e. orthopedic plate and screw insertion, to stabilize the injury and facilitate tissue repair. If the surrounding bone quality is poor the screws may migrate, or the bone may fail, resulting in fixation failure. While numerous studies have shown that cement augmentation of the interface between bone and implant can increase screw pull-out force, the physical properties of cement that influence pull-out force have not been investigated. The present study sought to determine how the physical properties of high strength calcium phosphate cements (hsCPCs, specifically dicalcium phosphate) affected the corresponding orthopedic screw pull-out force in urethane foam models of "healthy" and "osteoporotic" synthetic bone (Sawbones). In the simplest model, where only the bond strength between screw thread and cement (without Sawbone) was tested, the correlation between pull-out force and cement compressive strength (R 2 = 0.79) was weaker than correlation with total cement porosity (R 2 = 0.89). In open pore Sawbone that mimics "healthy" cancellous bone density the stronger cements produced higher pull-out force (50-60% increase). High strength, low porosity cements also produced higher pull-out forces (50-190% increase) in "healthy" Sawbones with cortical fixation if the failure strength of the cortical material was similar to, or greater than (a metal shell), actual cortical bone. This result is of particular clinical relevance where fixation with a metal plate implant is indicated, as the nearby metal can simulate a thicker cortical shell, thereby increasing the pull-out force of screws augmented with stronger cements. The improvement in pull-out force was apparent even at low augmentation volumes of 0.5mL (50% increase), which suggest that in clinical situations where augmentation volume is limited the stronger, lower porosity calcium phosphate cement (CPC) may still produce a significant improvement in screw pull-out force. When the correlation strength of all the tested models were compared both cement porosity and compressive strength accurately predicted pull-out force (R 2 =1.00, R 2 =0.808), though prediction accuracy depended upon the strength of the material surrounding the Sawbone. The correlations strength was low for bone with no, or weak, cortical fixation (R 2 =0.56, 0.36). Higher strength and lower porosity CPCs also produced greater pull-out force (1-1.5kN) than commercial CPC (0.2-0.5kN), but lower pull-out force than PMMA (2-3kN). The results of this study suggest that the likelihood of screw fixation failure may be reduced by selecting calcium phosphate cements with lower porosity and higher compressive strength, in patients with healthy bone mineral density and/or sufficient cortical thickness. This is of particular clinical relevance when fixation with metal plates is indicated, or where the augmentation volume is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Open Screw Placement in a 1.5 mm LCP Over a Fracture Gap Decreases Fatigue Life

    PubMed Central

    Alwen, Sarah G. J.; Kapatkin, Amy S.; Garcia, Tanya C.; Milgram, Joshua; Stover, Susan M.

    2018-01-01

    Objective To investigate the influence of plate and screw hole position on the stability of simulated radial fractures stabilized with a 1.5 mm condylar locking compression plate (LCP). Study Design In vitro mechanical testing of paired cadaveric limbs. Sample Population Paired radii (n = 7) stabilized with a 1.5 mm condylar LCP with an open screw hole positioned either proximal to (PG), or over (OG), a simulated small fracture gap. Methods Constructs were cycled in axial compression at a simulated trot load until failure or a maximum of 200,000 cycles. Specimens that sustained 200,000 cycles without failure were then loaded in axial compression in a single cycle to failure. Construct cyclic axial stiffness and gap strain, fatigue life, and residual strength were evaluated and compared between constructs using analysis of variance. Results Of pairs that had a failure during cyclic loading, OG constructs survived fewer cycles (54,700 ± 60,600) than PG (116,800 ± 49,300). OG constructs had significantly lower initial stiffness throughout cyclic loading and higher gap strain range within the first 1,000 cycles than PG constructs. Residual strength variables were not significantly different between constructs, however yield loads occurred at loads only marginally higher than approximated trot loads. Fatigue life decreased with increasing body weight. Conclusion Fracture fixation stability is compromised by an open screw hole directly over a fracture gap compared to the open screw hole being buttressed by bone in the model studied. The 1.5 mm condylar LCP may be insufficient stabilization in dogs with appropriate radial geometry but high body weights. PMID:29876361

  8. Intra-operative measurement of applied forces during anterior scoliosis correction.

    PubMed

    Fairhurst, H; Little, J P; Adam, C J

    2016-12-01

    Spinal instrumentation and fusion for the treatment of scoliosis is primarily a mechanical intervention to correct the deformity and halt further progression. While implant-related complications remain a concern, little is known about the magnitudes of the forces applied to the spine during surgery, which may affect post-surgical outcomes. In this study, the compressive forces applied to each spinal segment during anterior instrumentation were measured in a series of patients with Adolescent Idiopathic Scoliosis. A force transducer was designed and retrofit to a routinely used surgical tool, and compressive forces applied to each segment during surgery were measured for 15 scoliosis patients. Cobb angle correction achieved by each force was measured on intra-operative fluoroscope images. Relative changes in orientation of the screw within the vertebra were also measured to detect intra-operative screw plough. Intra-operative forces were measured for a total of 95 spinal segments. The mean applied compressive force was 540N (SD 230N, range 88N-1019N). There was a clear trend for higher forces to be applied at segments toward the apex of the scoliosis. Fluoroscopic evidence of screw plough was detected at 10 segments (10.5%). The magnitude of forces applied during anterior scoliosis correction vary over a broad range. These forces do reach magnitudes capable of causing intra-operative vertebral body screw plough. Surgeons should be aware there is a risk for tissue overload during correction, however the clinical implications of intra-operative screw plough remain unclear. The dataset presented here is valuable for providing realistic input parameters for in silico surgical simulations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants.

    PubMed

    García-Roncero, Herminio; Caballé-Serrano, Jordi; Cano-Batalla, Jordi; Cabratosa-Termes, Josep; Figueras-Álvarez, Oscar

    2015-04-01

    In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30° in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

  10. Microstructural investigation of plastically deformed Ti{sub 20}Zr{sub 20}Hf{sub 20}Nb{sub 20}Ta{sub 20} high entropy alloy by X-ray diffraction and transmission electron microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dirras, G., E-mail: dirras@univ-paris13.fr; Gubicza, J.; Heczel, A.

    2015-10-15

    The microstructure evolution in body-centered cubic (bcc) Ti{sub 20}Zr{sub 20}Hf{sub 20}Nb{sub 20}Ta{sub 20} high entropy alloy during quasi-static compression test was studied by X-ray line profile analysis (XLPA) and transmission electron microscopy (TEM). The average lattice constant and other important parameters of the microstructure such as the mean crystallite size, the dislocation density and the edge/screw character of dislocations were determined by XLPA. The elastic anisotropy factor required for XLPA procedure was determined by nanoindentation. XLPA shows that the crystallite size decreased while the dislocation density increased with strain during compression, and their values reached about 39 nm and 15more » × 10{sup 14} m{sup −2}, respectively, at a plastic strain of ~ 20%. It was revealed that with increasing strain the dislocation character became more screw. This can be explained by the reduced mobility of screw dislocations compared to edge dislocations in bcc structures. These observations are in line with TEM investigations. The development of dislocation density during compression was related to the yield strength evolution. - Highlights: • Ti{sub 20}Zr{sub 20}Hf{sub 20}Nb{sub 20}Ta{sub 20} high entropy alloy was processed by arc-melting. • The mechanical was evaluated by RT compression test. • The microstructure evolution was studied by XLPA and TEM. • With increasing strain the dislocation character became more screw. • The yield strength was related to the development of the dislocation density.« less

  11. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    PubMed

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The treatment protocol based on use of biaxial Medoff sliding plate for unstable pertrochanteric and uniaxial Medoff sliding plate for subtrochanteric fractures reduced the risk of severe technical complications compared to using the treatment protocol based on dynamic hip screw and intramedullary nail.

  12. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    PubMed

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E

    2017-06-01

    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  13. In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants

    PubMed Central

    2015-01-01

    PURPOSE In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30° in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants. PMID:25932315

  14. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    PubMed

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of the screw designs.

  15. Research of the value of linear distortion of renewable surface of part during rotary processing of bulky items without dismantling unit

    NASA Astrophysics Data System (ADS)

    Bondarenko, J. A.; Fedorenko, M. A.; Pogonin, A. A.

    2018-03-01

    The loading and unloading units and grinding mills of raw devices have internal cone type or pipe screw perceive load of incoming and outgoing material. The main part of the support assembly is a pin. Mounting seats for the pipe screws cone have traces of deformation and work hardening, while they themselves have wear of pins and deformation of the inner and outer cylindrical working surface. In the mill body, there are constantly acting dynamic forces causing vibration, which are transmitted to the stud and inner accelerating elements. Under the influence of stress and vibration, the housing spigot is in the stress-compressed state and stretched vertically and horizontally. As a result, the insertion element is deformed and weakened in the fixture. A moving element appears in the gap leading to the fact that it drops lfeedstock and under the influence of variable loads it is destroyed, as well as the seating surfaces of the insert pin member.

  16. Predicting cancellous bone failure during screw insertion.

    PubMed

    Reynolds, Karen J; Cleek, Tammy M; Mohtar, Aaron A; Hearn, Trevor C

    2013-04-05

    Internal fixation of fractures often requires the tightening of bone screws to stabilise fragments. Inadequate application of torque can leave the fracture unstable, while over-tightening results in the stripping of the thread and loss of fixation. The optimal amount of screw torque is specific to each application and in practice is difficult to attain due to the wide variability in bone properties including bone density. The aim of the research presented in this paper is to investigate the relationships between motor torque and screw compression during powered screw insertion, and to evaluate whether the torque during insertion can be used to predict the ultimate failure torque of the bone. A custom test rig was designed and built for bone screw experiments. By inserting cancellous bone screws into synthetic, ovine and human bone specimens, it was established that variations related to bone density could be automatically detected through the effects of the bone on the rotational characteristics of the screw. The torque measured during screw insertion was found to be directly related to bone density and can be used, on its own, as a good predictor of ultimate failure torque of the bone. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  17. The Biomechanical Properties of Pedicle Screw Fixation Combined With Trajectory Bone Cement Augmentation in Osteoporotic Vertebrae.

    PubMed

    Fan, Haitao T; Zhang, Renjie J; Shen, Cailiang L; Dong, Fulong L; Li, Yong; Song, Peiwen W; Gong, Chen; Wang, Yijin J

    2016-03-01

    The biomechanics of pedicle screw fixation combined with trajectory cement augmentation with various filling volumes were measured by pull-out, periodic antibending, and compression fatigue tests. To investigate the biomechanical properties of the pedicle screw fixation combined with trajectory bone cement (polymethylmethacrylate) augmentation in osteoporotic vertebrae and to explore the optimum filling volume of the bone cement. Pedicle screw fixation is considered to be the most effective posterior fixation method. The decrease of the bone mineral density apparently increases the fixation failure risk caused by screw loosening and displacement. Trajectory bone cement augmentation has been confirmed to be an effective method to increase the bone intensity and could markedly increase the stability of the fixation interface. Sixteen elderly cadaveric 1-5 lumbar vertebral specimens were diagnosed with osteoporosis. The left and right vertebral pedicles were alternatively randomized for treatment in all groups, with the contralateral pedicles as control. The study groups included: group A (pedicle screw fixation with full trajectory bone cement augmentation), group B (75% filling), group C (50% filling), and group D (25% filling). Finally, the bone cement leakage and dispersion were assessed and the mechanical testing was conducted. The bone cement was well dispersed around the pedicle screw. The augmented bone intensity, pull-out strength, periodic loading times, and compression fatigue performance were markedly higher than those of the control groups. With the increase in trajectory bone cement, the leakage was also increased (P<0.05). The pull-out strength of the pedicle screw was increased with an increase in bone mineral density and trajectory bone cement. It peaked at 75% filling, with the largest power consumption. The optimal filling volume of the bone cement was 75% of the trajectory volume (about 1.03 mL). The use of excessive bone cement did not increase the fixation intensity but increased the risk of leakage.

  18. Mechanical stability of a novel screw design after repeated insertion: can the double-thread screw serve as a back up?

    PubMed

    Wiendieck, Kurt; Müller, Helge; Buchfelder, Michael; Sommer, Björn

    2018-06-01

    We investigated mechanical pull-out behavior and tightening torque of a novel dual-core pedicle "6T screw" (6T). The aim of this study was to test if these changes in screw geometry are increasing the strength of the pedicle screw fixation after repeated insertion. Three different types of pedicle screws were inserted in rigid foam blocks. Tightening torque and pull-out strength were measured during two repetitive insertions of a standard 6.5×45-mm conical screw. The third insertion into the pilot hole was performed using either standard 6.5×45-mm or 7.2×45-mm conical screws or the novel 6.5×45-mm (6T) screw. Additionally, we performed a surface analysis to investigate the bone/screw interface. The maximal tightening torque at the third insertion of the novel 6T screw was 194% higher compared to the standard 6.5×45-mm conical screw and 135% higher compared to the standard 7.2×45-mm conical screw. The pull-out strength of the 6T screw showed no significant changes, and surface analysis revealed a compression of the screw-foam interface due to the different internal diameters. The modified geometrical design of the 6T screw seems to have no statistically significant effect on the pull-out strength, although it achieved a higher tightening torque. This might be due to the different pitch angle cutting a new thread into the material and also to the enlarged inner diameter.

  19. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. A novel compact compliant actuator design for rehabilitation robots.

    PubMed

    Yu, Haoyong; Huang, Sunan; Thakor, Nitish V; Chen, Gong; Toh, Siew-Lok; Sta Cruz, Manolo; Ghorbel, Yassine; Zhu, Chi

    2013-06-01

    Rehabilitation robots have direct physical interaction with human body. Ideally, actuators for rehabilitation robots should be compliant, force controllable, and back drivable due to safety and control considerations. Various designs of Series Elastic Actuators (SEA) have been developed for these applications. However, current SEA designs face a common performance limitation due to the compromise on the spring stiffness selection. This paper presents a novel compact compliant force control actuator design for portable rehabilitation robots to overcome the performance limitations in current SEAs. Our design consists of a servomotor, a ball screw, a torsional spring between the motor and the ball screw, and a set of translational springs between the ball screw nut and the external load. The soft translational springs are used to handle the low force operation and reduce output impedance, stiction, and external shock load. The torsional spring, being in the high speed range, has high effective stiffness and improves the system bandwidth in large force operation when the translational springs are fully compressed. This design is also more compact due to the smaller size of the springs. We explain the construction and the working principle of our new design, followed by the dynamic modeling and analysis of the actuator. We also show the preliminary testing results of a prototype actuator designed for a lower limb exoskeleton for gait rehabilitation.

  1. Epidural spinal cord compression with neurologic deficit associated with intrapedicular application of hemostatic gelatin matrix during pedicle screw insertion.

    PubMed

    Buchowski, Jacob M; Bridwell, Keith H; Lenke, Lawrence G; Good, Christopher R

    2009-06-01

    Case report. In order to demonstrate the dangers of intrapedicular application of a hemostatic gelatin matrix to decrease blood loss during pedicle screw insertion, we present 2 patients who--as a result of inadvertent extravasation of the matrix into the spinal canal--developed epidural spinal cord compression (ESCC) requiring emergent decompression. Variety of hemostatic agents can control bleeding during pedicle screw insertion. We have often used a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles by injecting the material into the pedicle after manually palpating the pedicle. Medical records and radiographic studies of 2 patients with AIS who underwent surgical treatment of their deformity and developed a neurologic deficit due to extravasation of FloSeal were reviewed. A 15 year-old male underwent T4 to L2 posterior spinal fusion (PSF). During pedicle screw insertion, a change in NMEPs and SSEPs was noted. A wake-up test confirmed bilateral LE paraplegia. Screws were removed and no perforations were noted on manual palpation. MRI showed T7 to T10 ESCC. He underwent a T5 to T10 laminectomy and hemostatic gelatin matrix noted in the canal and was evacuated. He was ambulatory at 2 weeks and by 3 months he had complete recovery. The second patient was a 15 year-old female who underwent T4 to L1 PSF. Following screw insertion, deterioration in NMEPs and SSEPs was noted. Screws were removed and SCM data returned to baseline. Except for 3 screws that had an inferior breach (Left T7 and Bilateral T8), screws were reinserted and remainder of the surgery was uneventful. Postoperative examination was normal initially but 2 days later, she developed left LE numbness/weakness. Implants were removed and MRI showed T4 to T9 ESCC.She underwent a left (concave) T4 to T9 hemilaminectomy. Hemostatic gelatin matrix was noted and was evacuated. Six weeks following surgery, she had a complete neurologic recovery. The use of a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles during pedicle screw insertion can result in inadvertent extravasation into the spinal canal resulting in ESCC even in the absence of an apparent medial pedicle breach. Given the dangers associated with the technique, we recommend that gelatin matrix products be used judiciously during pedicle screw insertion.

  2. Central cooling: compressive chillers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christian, J.E.

    1978-03-01

    Representative cost and performance data are provided in a concise, useable form for three types of compressive liquid packaged chillers: reciprocating, centrifugal, and screw. The data are represented in graphical form as well as in empirical equations. Reciprocating chillers are available from 2.5 to 240 tons with full-load COPs ranging from 2.85 to 3.87. Centrifugal chillers are available from 80 to 2,000 tons with full load COPs ranging from 4.1 to 4.9. Field-assemblied centrifugal chillers have been installed with capacities up to 10,000 tons. Screw-type chillers are available from 100 to 750 tons with full load COPs ranging from 3.3more » to 4.5.« less

  3. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    PubMed Central

    Karaarslan, Ahmet A; Karakaşli, Ahmet; Aycan, Hakan; Çeçen, Berivan; Yildiz, Didem Venüs; Sesli, Erhan

    2016-01-01

    Background: Proximal locking screw deformation and screw fracture is a frequently seen problem for femur interlocking nailing that affects fracture healing. We realized that there is lack of literature for the right level for the proximal locking screw. We investigated the difference of locking screw bending resistance between the application of screws on different proximal femoral levels. Materials and Methods: We used a total of 80 proximal locking screws for eight groups, 10 screws for each group. Three-point bending tests were performed on four types of screws in two different trochanteric levels (the lesser trochanter and 20 mm proximal). We determined the yield points at three-point bending tests that a permanent deformation started in the locking screws using an axial compression testing machine. Results: The mean yield point value of 5 mm threaded locking screws applied 20 mm proximal of lesser trochanter was 1022 ± 49 (range 986–1057) (mean ± standard deviation, 95% confidence interval). On the other hand, the mean yield point value of the same type of locking screws applied on the lesser trochanteric level was 2089 ± 249 (range 1911–2268). Which means 103% increase of screw resistance between two levels (P = 0.000). In all screw groups, on the lesser trochanter line we determined 98–174% higher than the yield point values of the same type of locking screws in comparison with 20 mm proximal to the lesser trochanter (P = 0.000). Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures. PMID:26955183

  4. Coal extrusion in the plastic state

    NASA Technical Reports Server (NTRS)

    England, C.; Ryason, P. R.

    1977-01-01

    Continuous feeding of coal in a compressing screw extruder is described as a method of introducing coal into pressurized systems. The method utilizes the property of many bituminous coals of softening at temperatures from 350 to 425 C. Coal is then fed, much in the manner of common thermoplastics, using screw extruders. Data on the viscosity and extruder parameters for extrusion of Illinois No. 6 coal are presented.

  5. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

    PubMed

    Takeba, Jun; Umakoshi, Kensuke; Kikuchi, Satoshi; Matsumoto, Hironori; Annen, Suguru; Moriyama, Naoki; Nakabayashi, Yuki; Sato, Norio; Aibiki, Mayuki

    2018-04-01

    Screw fixation for unstable pelvic ring fractures is generally performed using the C-arm. However, some studies reported erroneous piercing with screws, nerve injuries, and vessel injuries. Recent studies have reported the efficacy of screw fixations using navigation systems. The purpose of this retrospective study was to investigate the accuracy of screw fixation using the O-arm ® imaging system and StealthStation ® navigation system for unstable pelvic ring fractures. The participants were 10 patients with unstable pelvic ring fractures, who underwent screw fixations using the O-arm StealthStation navigation system (nine cases with iliosacral screw and one case with lateral compression screw). We investigated operation duration, bleeding during operation, the presence of complications during operation, and the presence of cortical bone perforation by the screws based on postoperative CT scan images. We also measured the difference in screw tip positions between intraoperative navigation screen shot images and postoperative CT scan images. The average operation duration was 71 min, average bleeding was 12 ml, and there were no nerve or vessel injuries during the operation. There was no cortical bone perforation by the screws. The average difference between intraoperative navigation images and postoperative CT images was 2.5 ± 0.9 mm, for all 18 screws used in this study. Our results suggest that the O-arm StealthStation navigation system provides accurate screw fixation for unstable pelvic ring fractures.

  6. Viscoelastic stability in a single-screw channel flow

    NASA Astrophysics Data System (ADS)

    Agbessi, Y.; Bu, L. X.; Béreaux, Y.; Charmeau, J.-Y.

    2018-05-01

    In this work, we perform a linear stability analysis on pressure and drag flows of an Upper Convected Maxwell viscoelastic fluid. We use the well-recognised method of expanding the disturbances in Chebyschev polynomials and solve the resulting generalized eigenvalues problem with a collocation spectra method. Both the level of elasticity and the back-pressure vary. In a second stage, recent analytic solutions of viscoelastic fluid flows in slowly varying sections [1] are used to extend this stability analysis to flows in a compression or in a diverging section of a single screw channel, for example a wave mixing screw.

  7. Finite element analysis and cadaveric cinematic analysis of fixation options for anteriorly implanted trabecular metal interbody cages.

    PubMed

    Berjano, Pedro; Blanco, Juan Francisco; Rendon, Diego; Villafañe, Jorge Hugo; Pescador, David; Atienza, Carlos Manuel

    2015-11-01

    To assess, with finite element analysis and an in vitro biomechanical study in cadaver, whether the implementation of an anterior interbody cage made of hedrocel with nitinol shape memory staples in compression increases the stiffness of the stand-alone interbody cage and to compare these constructs' stiffness to other constructs common in clinical practice. A biomechanical study with a finite element analysis and cadaveric testing assessed the stiffness of different fixation modes for the L4-L5 functional spinal unit: intact spine, destabilized spine with discectomy, posterior pedicle-screw fixation, anterior stand-alone interbody cage, anterior interbody cage with bilateral pedicle screws and anterior interbody cage with two shape memory staples in compression. These modalities of vertebral fixation were compared in four loading modes (flexion, extension, lateral bending, and axial rotation). The L4-L5 spinal unit with an anterior interbody cage and two staples was stiffer than the stand-alone cage. The construct stiffness was similar to that of a model of posterior pedicular stabilization. The stiffness was lower than that of the anterior cage plus bilateral pedicle-screw fixation. The use of an anterior interbody implant with shape memory staples in compression may be an alternative to isolated posterior fixation and to anterior isolated implants, with increased stiffness.

  8. [Arthrodesis of the shoulder. A new and soft-tissue-sparing technique with a deep locking plate in the supraspinatus fossa].

    PubMed

    Klonz, A; Habermeyer, P

    2007-10-01

    Arthrodesis of the glenohumeral joint is a difficult intervention that involves a relatively high probability of complications. A stable internal fixation and secure consolidation is required. The operation needs to achieve several conditions: thorough denudation of the cartilage and partial decortication of the subchondral bone; good congruence of the corresponding surfaces; compression of the gap by tension screws and lasting stability. For increased primary stability a neutralizing plate is generally used as well as a compression screw. Up to now, the plate has usually been applied starting from the scapular spine and extending across the acromial corner to the humeral shaft. A wide exposure is needed for this procedure; the plate is difficult to shape during the operation and often causes some discomfort because it protrudes at the acromial corner. We present an alternative position of the plate in the supraspinatus fossa, where we have sited a 4.5 mm LCP locking plate (Synthes). The implant is inserted under the acromion, does not cause any discomfort at the acromial corner, and is far easier to shape. When it is used in association with a transarticular compressive screw, the technique results in a very stable situation, which allows physiotherapy from the first day after surgery onward.

  9. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    PubMed

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P <0.05), and the average stress and peak stress were significantly lower than in other 3 groups ( P <0.05). The acetabular weight-bearing area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P <0.05). There was no significant difference in the above indexes between group B and group C ( P >0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  10. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    PubMed

    Yang, Jesse Chieh-Szu; Chen, Hsin-Chang; Lai, Yu-Shu; Cheng, Cheng-Kung

    2017-01-01

    Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  11. Strain-Rate Dependence of Deformation-Twinning in Tantalum

    NASA Astrophysics Data System (ADS)

    Abeywardhana, Jayalath; Germann, Tim; Ravelo, Ramon

    2017-06-01

    Large-Scale molecular dynamics (MD) simulations are used to model quasi-isentropic compression and expansion (QIC) in tantalum crystals varying the rate of deformation between the range 108 -1012s-1 and compressive pressures up to 100 GPa. The atomic interactions were modeled employing an embedded-atom method (EAM) potential of Ta. Isentropic expansion was done employing samples initially compressed to pressures of 60 and 100 GPa followed by uniaxial and quasi-isentropically expansion to zero pressure. The effect of initial dislocation density on twinning was also examined by varying the initial defect density of the Ta samples (1010 -1012cm-2). At these high-strain rates, a threshold in strain-rate on deformation twining is observed. Under expansion or compression, deformation twinning increases with strain rate for strain-rates >109s-1 . Below this value, small fraction of twins nucleates but anneal out with time. Samples with lower fraction of twins equilibrate to defect states containing higher screw dislocation densities from those with initially higher twinning fractions. This work was supported by the Department of Energy under contract DE-AC52-06NA25396 and by the Air Force Office of Scientific Research under AFOSR Award No. FA9550-12-1-0476.

  12. Comparing fixation used for calcaneal displacement osteotomies: a look at removal rates and cost.

    PubMed

    Lucas, Douglas E; Simpson, G Alex; Philbin, Terrence M

    2015-02-01

    The calcaneal displacement osteotomy is a procedure frequently used by foot and ankle surgeons for hindfoot angular deformity. Traditional techniques use compression screw fixation that can result in prominent hardware. While the results of the procedure are generally good, a common concern is the development of plantar heel pain related to prominent hardware. The primary purpose of this study is to retrospectively compare clinical outcomes of 2 fixation methods for the osteotomy. Secondarily a cost analysis will compare implant costs to hardware removal costs. Records were reviewed for patients who had undergone a calcaneal displacement osteotomy fixated with either lag screw or a locked lateral compression plate (LLCP). Neuropathy, previous ipsilateral calcaneus surgery, heel pad trauma, or incomplete radiographic follow-up were exclusionary. Thirty-two patients (19.4%) required hardware removal from the screw fixation group compared to 1 (1.6%) of the LLCP group, which is significant (P < .05). Time to radiographic healing was not significantly different (P = .87). The screw fixation group required more follow-up visits over a longer period of time (P < .05). Implant cost was remarkably different with screw fixation costing on average $247.12, compared to the LLCP costing $1175.59. Although the LLCP cost was significantly higher, cost savings were identified when the cost of removal and removal rates were included. This study demonstrates that this device provides adequate stabilization for healing in equivalent time to screw fixation. The LLCP required decreased rates of hardware removal with fewer postoperative visits over a shorter period of time. Significant savings were demonstrated in the LLCP group despite the higher implant cost. Therapeutic, Level III, Retrospective Comparative Study. © 2014 The Author(s).

  13. Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study.

    PubMed

    Konya, Mehmet Nuri; Verim, Özgür

    2017-09-29

    Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. Biomechanical study. Computed tomography images of patients' right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis.

  14. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    PubMed

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  15. A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures.

    PubMed

    Patil, Sunit; Mahon, Andrew; Green, Sarah; McMurtry, Ian; Port, Andrew

    2006-06-01

    There has been a recent trend towards using a raft of small diameter 3.5mm cortical screws for supporting depressed tibial plateau fractures (Schatzker type III). Our aim was to compare the biomechanical properties of a raft of 3.5 mm cortical screws with that of 6.5 mm cancellous screws in a synthetic bone model. Ten rigid polyurethane foam (sawbone) blocks, with a density simulating osteoporotic bone and ten blocks with a density simulating normal density bone were obtained. A Schatzker type III fracture was created in each block. The fracture fragments were then elevated and supported using two 6.5 mm cancellous screws in ten blocks and four 3.5 mm cortical screws in the remaining. The fractures were loaded using a Lloyd testing machine. The mean force needed to produce a depression of 5 mm was 700.8 N with the four-screw construct and 512.4 N with the two-screw construct in the osteoporotic model. This difference was highly statistically significant (p = 0.009). The mean force required to produce the same depression was 1878.2 N with the two-screw construct and 1938.2 N with the four-screw construct in the non-osteoporotic model. Though the difference was not statistically significant (p = 0.42), an increased fragmentation of the synthetic bone fragments was noticed with the two-screw construct but not with the four-screw construct. A raft of four 3.5 mm cortical screws is biomechanically stronger than two 6.5 mm cancellous screws in resisting axial compression in osteoporotic bone.

  16. [The biomechanics of screws, cerclage wire and cerclage cable].

    PubMed

    Schröder, C; Woiczinski, M; Utzschneider, S; Kraxenberger, M; Weber, P; Jansson, V

    2013-05-01

    In contrast to fracture fixation, when performing an osteotomy the surgeon is able to plan preoperatively. The resulting fixation and compression of the bone fragments are the most important points. A stable osteosynthesis should prevent dislocation of bone fragments and improve bone healing. Beside plates, cerclages can be used for tension band or diaphysis bone fixation. Moreover, cortical or cancellous screws can be used for osteotomy fixation. This work describes biomechanical principles for fixation after an osteotomy with cerclages and cortical or cancellous screws. It also summarizes the materials and geometries used, as well as their influence on the stability of the osteosynthesis.

  17. Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength

    PubMed Central

    Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.

    2015-01-01

    Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255

  18. Rotor blade construction for circulation control aircraft

    NASA Technical Reports Server (NTRS)

    Carter, Sr., Donald R. (Inventor); Sedlak, Matthew (Inventor); Krauss, Timothy A. (Inventor)

    1986-01-01

    A circulation control aircraft rotor blade having a spanwise Coanda surface 16 and a plurality of spanwise extending flexible composite material panels 18 cooperating with the surface to define slots for the discharge of compressed air from within the blade with each panel having first flexure means 60 associated with screw adjustments 36 for establishing a slot opening preload and second flexure means 62 associated with screw adjustments 38 for establishing a slot maximum opening.

  19. A novel technique to prevent guide wire related complications while inserting the 4.0 mm cannulated screws.

    PubMed

    Qi, Bao-Chang; Ju, Wei-Na; Wang, Tie-Jun; Yu, Tie-Cheng; Zhao, Yi; Sun, Da-Hui

    2015-01-01

    Cannulated screws (4.0 mm) provide inter-fragmentary compression and stability to fractures. A guide wire is used to define the screw trajectory and hold the fracture fragment while the screw is being inserted. The cannulated shaft typically accommodates a 1.25 mm guide pin. Since the guide pin is very slender and undergoes elastic deformation during insertion, there is a high probability of pin breakage. The authors have devised a new way to place the 4.0 mm cannulated screws in a manner that prevents the intraoperative complication of guide wire breakage. For this technique, predrilling was achieved using a 2.0 mm K-wire which was subsequently replaced with a 1.25 mm guide pin under the protection of sleeve. 4.0 mm cannulated screws were then inserted into a defined trajectory over the guide pin. Using the technique, over 20 patients were managed in our department over a period of two years without any complications. We have observed that patients treated with this method experience short operation time, combined with good clinical outcome and we recommend its use in cases where cannulated screw use is warranted.

  20. Proximal Pole Scaphoid Nonunion Reconstruction With 1,2 Intercompartmental Supraretinacular Artery Vascularized Graft and Compression Screw Fixation.

    PubMed

    Morris, Mark S; Zhu, Andy F; Ozer, Kagan; Lawton, Jeffrey N

    2018-02-06

    To review the incidence of union of patients with proximal pole scaphoid fracture nonunions treated using a 1,2 intercompartmental supraretinacular artery (1,2 ICSRA) vascularized graft and a small compression screw. This is a retrospective case series of 12 patients. Calculations of the size of the proximal pole fragment relative to the total scaphoid were performed using posteroanterior view scaphoid radiographs with the wrist in ulnar deviation and flat on the cassette. Analyses were repeated 3 times per subject, and the average ratio of proximal pole fragment relative to the entire scaphoid was calculated. We reviewed medical records, radiographs, and computed tomography (CT) scans of these 12 patients. The CT scans that were performed after an average of 12 weeks were ultimately used to confirm union of the scaphoid fractures. One patient was unable to have a CT so was excluded from the final calculation. All 11 (100%) scaphoid fractures that were assessed by CT were found to be healed at the 12-week assessment point. The mean proximal pole fragment size was 18% (range, 7%-27%) of the entire scaphoid. The 1,2 ICSRA vascularized graft and compression screw was an effective treatment for patients with proximal pole scaphoid fractures. Therapeutic IV. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Performance Testing of Jefferson Lab 12 GeV Helium Screw Compressors

    DOE PAGES

    Knudsen, P.; Ganni, V.; Dixon, K.; ...

    2015-08-10

    Oil injected screw compressors have essentially superseded all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, reliability, minimal vibration, and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium refrigeration systems, typically two-thirds of the lost input power is due to the compression system. It is important to understand the isothermal and volumetric efficiencies of these machines to help properly design the compression system to match the refrigeration process. It is also important to identify those primary compressor skid exergetic loss mechanisms which maymore » be reduced, thereby offering the possibility of significantly reducing the input power to helium refrigeration processes which are extremely energy intensive. This paper summarizes the results collected during the commissioning of the new compressor system for Jefferson Lab's (JLab's) 12 GeV upgrade. The compressor skid packages were designed by JLab and built to print by industry. They incorporate a number of modifications not typical of helium screw compressor packages and most importantly allow a very wide range of operation so that JLab's patented Floating Pressure Process can be fully utilized. This paper also summarizes key features of the skid design that allow this process and facilitate the maintenance and reliability of these helium compressor systems.« less

  2. Performance Testing of Jefferson Lab 12 GeV Helium Screw Compressors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knudsen, P.; Ganni, V.; Dixon, K.

    Oil injected screw compressors have essentially superseded all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, reliability, minimal vibration, and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium refrigeration systems, typically two-thirds of the lost input power is due to the compression system. It is important to understand the isothermal and volumetric efficiencies of these machines to help properly design the compression system to match the refrigeration process. It is also important to identify those primary compressor skid exergetic loss mechanisms which maymore » be reduced, thereby offering the possibility of significantly reducing the input power to helium refrigeration processes which are extremely energy intensive. This paper summarizes the results collected during the commissioning of the new compressor system for Jefferson Lab's (JLab's) 12 GeV upgrade. The compressor skid packages were designed by JLab and built to print by industry. They incorporate a number of modifications not typical of helium screw compressor packages and most importantly allow a very wide range of operation so that JLab's patented Floating Pressure Process can be fully utilized. This paper also summarizes key features of the skid design that allow this process and facilitate the maintenance and reliability of these helium compressor systems.« less

  3. Foundations for computer simulation of a low pressure oil flooded single screw air compressor

    NASA Astrophysics Data System (ADS)

    Bein, T. W.

    1981-12-01

    The necessary logic to construct a computer model to predict the performance of an oil flooded, single screw air compressor is developed. The geometric variables and relationships used to describe the general single screw mechanism are developed. The governing equations to describe the processes are developed from their primary relationships. The assumptions used in the development are also defined and justified. The computer model predicts the internal pressure, temperature, and flowrates through the leakage paths throughout the compression cycle of the single screw compressor. The model uses empirical external values as the basis for the internal predictions. The computer values are compared to the empirical values, and conclusions are drawn based on the results. Recommendations are made for future efforts to improve the computer model and to verify some of the conclusions that are drawn.

  4. Multidirectional volar fixed-angle plating using cancellous locking screws for distal radius fractures--evaluation of three screw configurations in an extra-articular fracture model.

    PubMed

    Weninger, Patrick; Dall'Ara, Enrico; Drobetz, Herwig; Nemec, Wolfgang; Figl, Markus; Redl, Heinz; Hertz, Harald; Zysset, Philippe

    2011-01-01

    Volar fixed-angle plating is a popular treatment for unstable distal radius fractures. Despite the availability of plating systems for treating distal radius fractures, little is known about the mechanical properties of multidirectional fixed-angle plates. The aim of this study was to compare the primary fixation stability of three possible screw configurations in a distal extra-articular fracture model using a multidirectional fixed-angle plate with metaphyseal cancellous screws distally. Eighteen Sawbones radii (Sawbones, Sweden, model# 1027) were used to simulate an extra-articular distal radius fracture according to AO/OTA 23 A3. Plates were fixed to the shaft with one non-locking screw in the oval hole and two locking screws as recommended by the manufacturer. Three groups (n = 6) were defined by screw configuration in the distal metaphyseal fragment: Group 1: distal row of screws only; Group 2: 2 rows of screws, parallel insertion; Group 3: 2 rows of screws, proximal screws inserted with 30° of inclination. Specimens underwent mechanical testing under axial compression within the elastic range and load controlled between 20 N and 200 N at a rate of 40 N/s. Axial stiffness and type of construct failure were recorded. There was no difference regarding axial stiffness between the three groups. In every specimen, failure of the Sawbone-implant-construct occurred as plastic bending of the volar titanium plate when the dorsal wedge was closed. Considering the limitations of the study, the recommendation to use two rows of screws or to place screws in the proximal metaphyseal row with inclination cannot be supported by our mechanical data.

  5. Suitability of DCPs with screw locking elements to allow sufficient interfragmentary motion to promote secondary bone healing of osteoporotic fractures.

    PubMed

    Cuadrado, A; Yánez, A; Carta, J A; Garcés, G

    2013-06-01

    This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1, used for comparison purposes, represents a system comprised of a Locking Compression Plate (LCP) and eight locking screws. Groups 2 and 3 represent a system comprised of a DCP plate with eight cortical screws and two SLEs placed on the screws furthest from (group 2) and nearest to (group 3) the fracture. Group 4 represents the system comprised of a DCP plate with SLEs placed on all eight cortical screws. Cyclic compression tests of up to 10,000 load cycles were performed in order to determine the parameters of interest, namely the stiffnesses and the interfragmentary motion of the various configurations under consideration. Tukey's multiple comparison test was used to analyse the existence or otherwise of significant differences between the means of the groups. At 10,000 cycles, interfragmentary motion at the far cortex for group 2 was 0.60±0.04 mm and for group 3 0.59±0.03 mm (there being no significant differences: p=0.995). The mean interfragmentary motion at the far cortex of the LCP construct was 70% less than that of the two groups with 2SLEs (there being significant differences: p=1.1×10(-8)). In the case of group 4 this figure was 45% less than in groups 2 and 3 (there being significant differences: p=5.6×10(-6)). At 10,000 cycles, interfragmentary motion at the near cortex for group 2 was 0.24±0.06 mm and for group 3 0.24±0.03 mm (there being no significant differences: p=1.000). The mean interfragmentary motion at the near cortex of the LCP construct was 70.8% less than that of the two groups with 2SLEs (there being significant differences: p=0.011). In the case of group 4 this figure was 66.7% less than in groups 2 and 3 (there being significant differences: p=0.016). The mean stiffness at 10,000 cycles was 960±110 N mm(-1) for group 2 and 969±53 N mm(-1) for group 3 (there being no significant differences: p=1.000). For group 1 (the LCP construct) the mean stiffness at 10,000 cycles was 3144±446 N mm(-1), 3.25 times higher than that of groups 2 and 3 (there being significant differences: p=0.00002), and 1.6 times higher than that of the DCP+8SLEs construct (1944±408 N mm(-1), there being significant differences: p=0.007). It is concluded that using the DCP+2SLEs construct sufficient interfragmentary motion is ensured to promote secondary bone healing. However, if too many SLEs are used the result may be, as with the LCP, an excessively rigid system for callus formation. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. New projects developed by COMOTI in gas industry

    NASA Astrophysics Data System (ADS)

    Nitulescu, Marian; Silivestru, Valentin; Toma, Niculae; Slujitoru, Cristian; Petrescu, Valentin; Leahu, Mihai; Oniga, Ciprian; Ulici, Gheorghe

    2015-08-01

    The paper aims to present two new projects developed by the Romanian Research and Development Institute for Gas Turbines (COMOTI) in partnership with City University of London and GHH-Rand Germany, in the field of screw compressors/expanders. COMOTI passed, in recent years, from being a GHH-Rand licensed manufacturer for a range of oil-injected screw compressors, of CU type, to a new phase of range diversification, approaching screw compressors with a maximum discharge pressure of 45 bara. So, in cooperation with City University and GHH-Rand we design, manufacture and test, with air, in COMOTI test bench the new type of screw compressor named CHP 220. Also, the cooperation with GHH-Rand has resulted in the design, manufacture and air testing on the test bench, and then gas testing - in a gas compression station - for an electric generator driven by a screw expander. This paper presents how the tests were carried out, the experimental data and the interpretation of results

  7. How Deformation Behavior Controls Product Performance After Twin Screw Granulation With High Drug Loads and Crospovidone as Disintegrant.

    PubMed

    Meier, Robin; Moll, Klaus-Peter; Krumme, Markus; Kleinebudde, Peter

    2017-01-01

    This study addresses the quantitative influence of 12 different materials (active pharmaceutical ingredients and excipients as surrogate active pharmaceutical ingredients) on the critical quality attributes of twin screw granulated products and subsequently produced tablets. Prestudies demonstrated the significant influence of the chosen model materials (in combination with crospovidone) on the disintegration behavior of the resulting tablets, despite comparable tablet porosities. This study elucidates possible reasons for the varying disintegration behavior by investigating raw material, granule, and tablet properties. An answer could be found in the mechanical properties of the raw materials and the produced granules. Through compressibility studies, the materials could be classified into materials with high compressibility, which deform rather plastically under compression stress, and low compressibility, which display breakages under compression stress. In general, and apart from (pseudo)-polymorphic transformations, brittle materials featured excellent disintegration performance, even at low resulting tablet porosities <8%, whereas plastically deformable materials mostly did not reveal any disintegration. These findings must be considered in the development of simplified formulations with high drug loads, in which the active pharmaceutical ingredient predominantly defines the deformation behavior of the granule. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. Which is the preferred revision technique for loosened iliac screw? A novel technique of boring cement injection from the outer cortical shell.

    PubMed

    Yu, Bin-Sheng; Yang, Zhan-Kun; Li, Ze-Min; Zeng, Li-Wen; Wang, Li-Bing; Lu, William Weijia

    2011-08-01

    An in vitro biomechanical cadaver study. To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P>0.05). Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.

  9. New method of feeding coal - Continuous extrusion of fully plastic coal

    NASA Technical Reports Server (NTRS)

    Ryason, P. R.; England, C.

    1978-01-01

    Continuous feeding of coal in a compressing screw extruder is described as a method of introducing coal into pressurized systems. The method utilizes the property of many bituminous coals of softening at temperatures from 350 to 400 C. Coal is then fed much in the manner of common thermoplastics, using screw extruders. Preliminary results show that coals can be extruded at rates of about 3.3 kg/MJ, similar to those for plastics.

  10. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    PubMed

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at P<.05. Type III distal phalanx fractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  11. Plantar Plating for the Treatment of Proximal Fifth Metatarsal Fractures in Elite Athletes.

    PubMed

    Mitchell, Ronald J; Duplantier, Neil L; Delgado, Domenica A; Lambert, Bradley S; McCulloch, Patrick C; Harris, Joshua D; Varner, Kevin E

    2017-05-01

    Proximal fifth metatarsal fractures, zones II and III, are commonly treated surgically, especially in elite athletes. Intramedullary screw fixation remains the most used construct despite nonunion and refracture. High tensile forces on the plantar-lateral aspect of the fifth metatarsal are difficult to control, and intramedullary screw fixation depends on ideal screw position, length, and width. The authors present a plantar plating technique with cancellous bone autograft for zones II and III proximal fifth metatarsal fractures. Rotational instability and plantar-lateral gapping are resisted by applying a compression plate to the tension side of the fracture, eliminating causes for failure. [Orthopedics. 2017; 40(3):e563-e566.]. Copyright 2017, SLACK Incorporated.

  12. Use of the S3 Corridor for Iliosacral Fixation in a Dysmorphic Sacrum: A Case Report.

    PubMed

    El Dafrawy, Mostafa H; Strike, Sophia A; Osgood, Greg M

    2017-01-01

    The S1 and S2 corridors are the typical osseous pathways for iliosacral screw fixation of posterior pelvic ring fractures. In dysmorphic sacra, the S1 screw trajectory is often different from that in normal sacra. We present a case of iliosacral screw placement in the third sacral segment for fixation of a complex lateral compression type-3 pelvic fracture in a patient with a dysmorphic sacrum. In patients with dysmorphic sacra and unstable posterior pelvic ring fractures or dislocations, the S3 corridor may be a feasible osseous fixation pathway that can be used in a manner equivalent to the S2 corridor in a normal sacrum.

  13. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    PubMed

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  14. Influence of screw length and diameter on tibial strain energy density distribution after anterior cruciate ligament reconstruction

    NASA Astrophysics Data System (ADS)

    Yao, Jie; Kuang, Guan-Ming; Wong, Duo Wai-Chi; Niu, Wen-Xin; Zhang, Ming; Fan, Yu-Bo

    2014-04-01

    Postoperative tunnel enlargement has been frequently reported after anterior cruciate ligament (ACL) reconstruction. Interference screw, as a surgical implant in ACL reconstruction, may influence natural loading transmission and contribute to tunnel enlargement. The aims of this study are (1) to quantify the alteration of strain energy den sity (SED) distribution after the anatomic single-bundle ACL reconstruction; and (2) to characterize the influence of screw length and diameter on the degree of the SED alteration. A validated finite element model of human knee joint was used. The screw length ranging from 20 to 30mm with screw diameter ranging from 7 to 9 mm were investigated. In the post-operative knee, the SED increased steeply at the extra-articular tunnel aperture under compressive and complex loadings, whereas the SED decreased beneath the screw shaft and nearby the intra-articular tunnel aperture. Increasing the screw length could lower the SED deprivation in the proximal part of the bone tunnel; whereas increasing either screw length or diameter could aggravate the SED deprivation in the distal part of the bone tunnel. Decreasing the elastic modulus of the screw could lower the bone SED deprivation around the screw. In consideration of both graft stability and SED alteration, a biodegradable interference screw with a long length is recommended, which could provide a beneficial mechanical environment at the distal part of the tunnel, and meanwhile decrease the bone-graft motion and synovial fluid propagation at the proximal part of the tunnel. These findings together with the clinical and histological factors could help to improve surgical outcome, and serve as a preliminary knowledge for the following study of biodegradable interference screw. [Figure not available: see fulltext.

  15. Development of the Gliding Hole of the Dynamics Compression Plate

    NASA Astrophysics Data System (ADS)

    Salim, U. A.; Suyitno; Magetsari, R.; Mahardika, M.

    2017-02-01

    The gliding hole of the dynamics compression plate is designed to facilitate relative movement of pedicle screw during surgery application. The gliding hole shape is then geometrically complex. The gliding hole manufactured using machining processes used to employ ball-nose cutting tool. Then, production cost is expensive due to long production time. This study proposed to increase productivity of DCP products by introducing forming process (cold forming). The forming process used to involve any press tool devices. In the closed die forming press tool is designed with little allowance, then work-pieces is trapped in the mould after forming. Therefore, it is very important to determine hole geometry and dimensions of raw material in order to success on forming process. This study optimized the hole sizes with both geometry analytics and experiments. The success of the forming process was performed by increasing the holes size on the raw materials. The holes size need to be prepared is diameter of 5.5 mm with a length of 11.4 mm for the plate thickness 3 mm and diameter of 6 mm with a length of 12.5 mm for the plate thickness 4 mm.

  16. Lateral mass screw-rod fixation of the cervical spine: a prospective clinical series with 1-year follow-up.

    PubMed

    Deen, H Gordon; Birch, Barry D; Wharen, Robert E; Reimer, Ronald

    2003-01-01

    Lateral mass plating has become the technique of choice for posterior cervical fixation. Although these systems are safe and reliable, they can be difficult to use in patients with abnormal cervical anatomy; screw placement can be compromised by the fixed hole spacing of the plate; screw back-out and other forms of implant failure can occur; and extension across the cervicothoracic junction can be problematic. To report a series of patients undergoing posterior cervical stabilization with a polyaxial screw-rod construct and to investigate whether this new system offers any advantages over existing methods of fixation. A prospective study evaluating clinical and radiographic parameters in a consecutive series of patients treated with this technique. There were 21 patients in the study group. The surgical indication was cervical spondylosis in 14, trauma in 2, postsurgical kyphosis in 2 and 1 case each of congenital cervicothoracic stenosis, C7-T1 pseudarthrosis and basilar invagination with brainstem compression. Clinical indicators included age, gender, neurologic status, surgical indication and number of levels stabilized. Note was made of whether laminectomy and concomitant anterior reconstructive surgery were performed. Radiographic indicators included early postoperative computed tomography (CT) scan to check for screw placement and plain radiographs at subsequent visits. The participants in this study underwent posterior cervical stabilization using lateral mass screw-rod fixation. Clinical and radiographic assessment was carried out immediately after surgery, and 3, 6 and 12 months after surgery. One-year follow-up was obtained in all cases. A total of 212 screws were implanted in 21 patients. Fixation was carried out over an average of 5.5 spinal segments (range, 2 to 11). The system was successfully implanted in all patients despite the presence of coronal and sagittal plane deformities and/or lateral mass abnormalities in the majority of cases. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-C7 lateral masses and upper thoracic pedicles. Early postoperative CT scanning confirmed satisfactory screw placement in all cases. Three patients experienced transient single-level radiculopathy, for an incidence of 1.4% per screw placed. Two patients developed wound seromas requiring evacuation. There were no infections or other wound healing problems. There were no examples of cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, loss of alignment or implant failure. When compared with plating techniques, screw-rod fixation appeared to offer several advantages. First, unlike plates, rods proved to be amenable to multiplanar contouring, which is often needed for deformities associated with cervical spondylosis. Second, lateral mass screw placement was more precise because it was not constrained by the hole spacing of the plate. Third, screw back-out and other types of implant failure were not seen. Fourth, the screw-rod system was more easily extended to the occiput and across the cervicothoracic junction. Fifth, the screw-rod system permitted the application of compression, distraction and reduction forces within the construct, to a greater extent than plate systems. The incidence of postoperative radiculopathy was similar to that seen with plate systems. These data indicate that posterior cervical stabilization with polyaxial screw-rod fixation is a safe, straightforward technique that appears to offer some advantages over existing methods of fixation. Results appear to be durable at 1-year follow-up. Benefits are more significant with longer constructs, especially those extending to the occiput or crossing the cervicothoracic junction.

  17. Distraction Arthrodesis of the C1-C2 Facet Joint with Preservation of the C2 Root for the Management of Intractable Occipital Neuralgia Caused by C2 Root Compression.

    PubMed

    Yeom, Jin S; Riew, K Daniel; Kang, Sung Shik; Yi, Jemin; Lee, Gun Woo; Yeom, Arim; Chang, Bong-Soon; Lee, Choon-Ki; Kim, Ho-Joong

    2015-10-15

    Prospective observational cohort study. To compare the outcomes of our new technique, distraction arthrodesis of C1-C2 facet joint with C2 root preservation (Study group), to those of conventional C1-C2 fusion with C2 root transection (Control group) for the management of intractable occipital neuralgia caused by C2 root compression. We are not aware of any report concerning C2 root decompression during C1-C2 fusion. Inclusion criteria were visual analogue scale (VAS) score for occipital neuralgia 7 or more; C2 root compression at the collapsed C1-C2 neural foramen; and follow-up 12 months or more. The Study group underwent surgery with our new technique including (1) C1-C2 facet joint distraction and bone block insertion while preserving the C2 root; and (2) use of C1 posterior arch screws instead of conventional lateral mass screws during C1-C2 segmental screw fixation. The Control group underwent C2 root transection with C1-C2 segmental screw fixation and fusion. We compared the prospectively collected outcomes data. There were 15 patients in the Study group and 8 in the Control group. Although there was no significant difference in the VAS score for the occipital neuralgia between the 2 groups preoperatively (8.2 ± 0.9 vs. 7.9 ± 0.6, P = 0.39), it was significantly lower in the Study group at 1, 3, and 6 months postoperatively (P < 0.01, respectively). At 12 months, it was 0.4 ± 0.6 versus 2.5 ± 2.6 (P = 0.01). There was no significant difference in improvement in the VAS score for neck pain and neck disability index and Japanese Orthopedic Association recovery rate, which are minimally influenced by occipital neuralgia. Our novel technique of distraction arthrodesis with C2 root preservation can be an effective option for the management of intractable occipital neuralgia caused by C2 root compression.

  18. The Pneumatic Actuators As Vertical Dynamic Load Simulators On Medium Weighted Wheel Suspension Mechanism

    NASA Astrophysics Data System (ADS)

    Ka'ka, Simon; Himran, Syukri; Renreng, Ilyas; Sutresman, Onny

    2018-02-01

    Almost all of road damage can be caused by dynamic loads of vehicles that fluctuate according to the type of vehicle that passes through. This study aims to calculate the vertical dynamic load of the vehicle actually occurs on road construction by the mechanism of vehicle wheel suspension. Pneumatic cylinders driven by pressurized air directly load the spring and shock absorber installed on the wheels of the vehicle. The load fluctuations of the medium weight categorized vehicles are determined by the regulation of the amount of pressurized air that enters into the pneumatic cylinder chamber, pushing the piston and connecting rods. The displacement that occurs during compression on the spring and shock absorber, is substituted into the equation of vehicle dynamic load while taking into account the spring stiffness constant, and the fluid or damper gas coefficient. The results show that the magnitude of the displacement when the compression force works has significant influences to the amount of vertical dynamic load of the vehicle that overlies the road construction. The presence of dynamic load of vehicles that fluctuates and repeats, also affects on the reduction of road ability to receive the load. Experimental results using pneumatic actuators instead of real dynamic vehicle loads illustrate the characteristics of the relationship between work pressure and dynamic load. If the working pressure of P2 (bar) is greater, the vertical dynamic load Ft (N) that overloads the road structure is also greater. The associate graphs show that the shock absorber has a greater ability to reduce dynamic load vertically that burden the road structure when compared with the ability of screw spring.

  19. Load Fatigue Performance Evaluation on Two Internal Tapered Abutment-Implant Connection Implants Under Different Screw Tightening Torques.

    PubMed

    Jeng, Ming-Dih; Liu, Po-Yi; Kuo, Jia-Hum; Lin, Chun-Li

    2017-04-01

    This study evaluates the load fatigue performance of different abutment-implant connection implant types-retaining-screw (RS) and taper integrated screwed-in (TIS) types under 3 applied torque levels based on the screw elastic limit. Three torque levels-the recommended torque (25 Ncm), 10% less, and 10% more than the ratio of recommended torque to screw elastic limits of different implants were applied to the implants to perform static and dynamic testing according to the ISO 14801 method. Removal torque loss was calculated for each group after the endurance limitation was reached (passed 5 × 10 6 cycles) in the fatigue test. The static fracture resistance results showed that the fracture resistance in the TIS-type implant significantly increased (P < .05) when the abutment screw was inserted tightly. The dynamic testing results showed that the endurance limitations for the RS-type implant were 229 N, 197 N, and 224 N and those for the TIS-type implant were 322 N, 364 N, and 376 N when the screw insertion torques were applied from low to high. The corresponding significant (P < .05) removal torque losses for the TIS-type implant were 13.2%, 5.3%, and 2.6% but no significant difference was found for the RS-type implant. This study concluded that the static fracture resistance and dynamic endurance limitation of the TIS-type implant (1-piece solid abutment) increased when torque was applied more tightly on the screw. Less torque loss was also found when increasing the screw insertion torque.

  20. Biomechanical Analysis of an Expandable Lumbar Interbody Spacer.

    PubMed

    Soriano-Baron, Hector; Newcomb, Anna G U S; Malhotra, Devika; Palma, Atilio E; Martinez-Del-Campo, Eduardo; Crawford, Neil R; Theodore, Nicholas; Kelly, Brian P; Kaibara, Taro

    2018-06-01

    Recently developed expandable interbody spacers are widely accepted in spinal surgery; however, the resulting biomechanical effects of their use have not yet been fully studied. We analyzed the biomechanical effects of an expandable polyetheretherketone interbody spacer inserted through a bilateral posterior approach with and without different modalities of posterior augmentation. Biomechanical nondestructive flexibility testing was performed in 7 human cadaveric lumbar (L2-L5) specimens followed by axial compressive loading. Each specimen was tested under 6 conditions: 1) intact, 2) bilateral L3-L4 cortical screw/rod (CSR) alone, 3) WaveD alone, 4) WaveD + CSR, 5) WaveD + bilateral L3-L4 pedicle screw/rod (PSR), and 6) WaveD + CSR/PSR, where CSR/PSR was a hybrid construct comprising bilateral cortical-level L3 and pedicle-level L4 screws interconnected by rods. The range of motion (ROM) with the interbody spacer alone decreased significantly compared with the intact condition during flexion-extension (P = 0.02) but not during lateral bending or axial rotation (P ≥ 0.19). The addition of CSR or PSR to the interbody spacer alone condition significantly decreased the ROM compared with the interbody spacer alone (P ≤ 0.002); and WaveD + CSR, WaveD + PSR, and WaveD + CSR/PSR (hybrid) (P ≥ 0.29) did not differ. The axial compressive stiffness (resistance to change in foraminal height during compressive loading) with the interbody spacer alone did not differ from the intact condition (P = 0.96), whereas WaveD + posterior instrumentation significantly increased compressive stiffness compared with the intact condition and the interbody spacer alone (P ≤ 0.001). The WaveD alone significantly reduced ROM during flexion-extension while maintaining the axial compressive stiffness. CSR, PSR, and CSR/PSR hybrid constructs were all effective in augmenting the expandable interbody spacer system and improving its stability. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Validity of computed tomography in predicting scaphoid screw prominence: a cadaveric study.

    PubMed

    Griffis, Clare E; Olsen, Cara; Nesti, Leon; Gould, C Frank; Frew, Michael; McKay, Patricia

    2017-04-01

    Studies of hardware protrusion into joint spaces following fracture fixation have been performed to address whether or not there is discrepancy between the actual and radiographic appearance of screw prominence. The purpose of our study was to prove that, with respect to the scaphoid, prominence as visualized on CT scan is real and not a result of metal artifact. Forty-two cadaveric wrists were separated into four allotted groups with 21 control specimens and 21 study specimens. All specimens were radiographically screened to exclude those with inherent carpal abnormalities. Acutrak® headless compression screws were placed into all specimens using an open dorsal approach. Cartilage was removed from screw insertion site at the convex surface of the scaphoid proximal pole. Control specimens had 0 mm screw head prominence. The studied specimens had 1, 2, and 3 mm head prominence measured with a digital caliper. Computed tomography, with direct sagittal acquisition and metal suppression technique, was then performed on all specimens following screw placement. Two staff radiologists blinded to the study groups interpreted the images. Results revealed that only one of 21 control specimens was interpreted as prominent. Comparatively, in the studied groups, 90% were accurately interpreted as prominent. CT provides an accurate assessment of scaphoid screw head prominence. When a screw appears prominent on CT scan, it is likely to be truly prominent without contribution from metallic artifact.

  2. Economics of water injected air screw compressor systems

    NASA Astrophysics Data System (ADS)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  3. Medial malleolar fractures: a biomechanical study of fixation techniques.

    PubMed

    Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G

    2011-08-08

    Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.

  4. Relative stability of tension band versus two-cortex screw fixation for treating fifth metatarsal base avulsion fractures.

    PubMed

    Husain, Z S; DeFronzo, D J

    2000-01-01

    This study assesses the strength of fixating avulsion fractures of the fifth metatarsal base with a 4.0-mm partially threaded cancellous screw crossing two cortices as compared to tension banding. Our data showed statistically significant fixation strength improvement over tension banding for avulsion fractures (p < 0.02) in both polystyrene foam models and fresh, nonpreserved frozen cadaveric samples. In cadavers, the screw fixations were able to withstand more than three times the load sustained by the tension band fixations. The study utilized the Instron 8500 tensiometer to apply physiologic loads to test the constructs until failure. The displacement and load data at failure show the limitations of both fixations. By increasing the load resistance while maintaining compression, the bicortical cancellous screw fixation created greater stability at the avulsion fracture of the fifth metatarsal base as compared to tension band stabilization.

  5. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.

    PubMed

    Griffiths, Jamie T; Taheri, Arash; Day, Robert E; Yates, Piers J

    2015-12-01

    The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  6. De-pulping and Seed Separation from Tumba ( Citrullus colocynthis) Fruit

    NASA Astrophysics Data System (ADS)

    Mudgal, Vishvambhar Dayal

    2017-09-01

    Tumba ( Citrullus colocynthis) contains spongy pulp in which seeds are embedded unevenly. Seeds contain about 26% fats and 13% protein. The process of seed separation is highly time consuming and labour intensive. Two weeks are required to separate its seeds with traditional methods. The developed prototype, for separating tumba seeds, mainly consists of chopper, de-pulping screw, barrel assembly and seed separation unit. The de-pulping screw and barrel assembly was divided in two sections i.e. conveying (feeding zone) and compression sections (de-pulping zone). The performance of developed machine was evaluated at different screw speed in the range of 40-100 rpm. Maximum pulp removal efficiency of 78.1% was achieved with screw speed of 60 rpm. Seed separation from the pulp was carried out by adding different chemicals. Use of sodium hydroxide and potassium hydroxide produced seed separation up to 99%.

  7. Dispersion and characterization of Thermoplastic Polyurethane/Multiwalled Carbon Nanotubes in co-rotative twin screw extruder

    NASA Astrophysics Data System (ADS)

    Benedito, Adolfo; Buezas, Ignacio; Giménez, Enrique; Galindo, Begoña

    2010-06-01

    The dispersion of multi-walled carbon nanotubes in thermoplastic polyurethanes has been done in co-rotative twin screw extruder through a melt blending process. A specific experimental design was prepared taking into account different compounding parameters such as feeding, temperature profile, screw speed, screw design, and carbon nanotube loading. The obtained samples were characterized by thermogravimetric analysis (TGA), light transmission microscopy, dynamic rheometry, and dynamic mechanical analysis. The objective of this work has been to study the dispersion quality of the carbon nanotubes and the effect of different compounding parameters to optimize them for industrial scale-up to final applications.

  8. Screw-symmetric gravitational waves: A double copy of the vortex

    NASA Astrophysics Data System (ADS)

    Ilderton, A.

    2018-07-01

    Plane gravitational waves can admit a sixth 'screw' isometry beyond the usual five. The same is true of plane electromagnetic waves. From the point of view of integrable systems, a sixth isometry would appear to over-constrain particle dynamics in such waves; we show here, though, that no effect of the sixth isometry is independent of those from the usual five. Many properties of particle dynamics in a screw-symmetric gravitational wave are also seen in a (non-plane-wave) electromagnetic vortex; we make this connection explicit, showing that the screw-symmetric gravitational wave is the classical double copy of the vortex.

  9. The influence of implant-abutment connection on the screw loosening and microleakage.

    PubMed

    Tsuruta, Katsuhiro; Ayukawa, Yasunori; Matsuzaki, Tatsuya; Kihara, Masafumi; Koyano, Kiyoshi

    2018-04-09

    There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant-abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant-abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. Within the limitation of the present study, CC was stable even after the loading in the RTV of abutment screw and it prevented microleakage from the microgap between the implant body and the abutment, among the three tested connections.

  10. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  11. Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density.

    PubMed

    Ab-Lazid, Rosidah; Perilli, Egon; Ryan, Melissa K; Costi, John J; Reynolds, Karen J

    2014-12-01

    For cancellous bone screws, the respective roles of the applied insertion torque (TInsert) and of the quality of the host bone (microarchitecture, areal bone mineral density (aBMD)), in contributing to the mechanical holding strength of the bone-screw construct (FPullout), are still unclear. During orthopaedic surgery screws are tightened, typically manually, until adequate compression is attained, depending on surgeons' manual feel. This corresponds to a subjective insertion torque control, and can lead to variable levels of tightening, including screw stripping. The aim of this study, performed on cancellous screws inserted in human femoral heads, was to investigate which, among the measurements of aBMD, bone microarchitecture, and the applied TInsert, has the strongest correlation with FPullout. Forty six femoral heads were obtained, over which microarchitecture and aBMD were evaluated using micro-computed tomography and dual X-ray absorptiometry. Using an automated micro-mechanical test device, a cancellous screw was inserted in the femoral heads at TInsert set to 55% to 99% of the predicted stripping torque beyond screw head contact, after which FPullout was measured. FPullout exhibited strongest correlations with TInsert (R=0.88, p<0.001), followed by structure model index (SMI, R=-0.81, p<0.001), bone volume fraction (BV/TV, R=0.73, p<0.001) and aBMD (R=0.66, p<0.01). Combinations of TInsert with microarchitectural parameters and/or aBMD did not improve the prediction of FPullout. These results indicate that, for cancellous screws, FPullout depends most strongly on the applied TInsert, followed by microarchitecture and aBMD of the host bone. In trabecular bone, screw tightening increases the holding strength of the screw-bone construct. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Polarity Control and Growth of Lateral Polarity Structures in AlN

    DTIC Science & Technology

    2013-05-10

    domains. Transmission electron microscopy shows mixed edge-screw type dislocations with polarity-dependent dislocation bending. Raman 1. REPORT DATE (DD-MM...polarity-dependent dislocation bending. Raman spectroscopy reveals compressively strained Al-polar and relaxed N-polar domains. The near band edge...dislocation bending. Raman spectroscopy reveals compressively strained Al-polar and relaxed N-polar domains. The near band edge luminescence consists of

  13. A novel fixation system for sacroiliac dislocation fracture: internal fixation system design and biomechanics analysis.

    PubMed

    Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai

    2013-02-01

    Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Feasibility of detecting orthopaedic screw overtightening using acoustic emission.

    PubMed

    Pullin, Rhys; Wright, Bryan J; Kapur, Richard; McCrory, John P; Pearson, Matthew; Evans, Sam L; Crivelli, Davide

    2017-03-01

    A preliminary study of acoustic emission during orthopaedic screw fixation was performed using polyurethane foam as the bone-simulating material. Three sets of screws, a dynamic hip screw, a small fragment screw and a large fragment screw, were investigated, monitoring acoustic-emission activity during the screw tightening. In some specimens, screws were deliberately overtightened in order to investigate the feasibility of detecting the stripping torque in advance. One set of data was supported by load cell measurements to directly measure the axial load through the screw. Data showed that acoustic emission can give good indications of impending screw stripping; such indications are not available to the surgeon at the current state of the art using traditional torque measuring devices, and current practice relies on the surgeon's experience alone. The results suggest that acoustic emission may have the potential to prevent screw overtightening and bone tissue damage, eliminating one of the commonest sources of human error in such scenarios.

  15. Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis--a histomorphological analysis in a dynamic system.

    PubMed

    Jacobsen, C; Obwegeser, J A

    2010-12-01

    Despite invention of titanium and resorbable screws and plates, still, one of the main challenges in bone fixation is the search for an ideal osteosynthetic material. Biomechanical properties, biocompatibility, and also cost effectiveness and clinical practicability are factors for the selection of a particular material. A promising alternative seems to be screws and plates made of bone. Recently, xenogenic bone pins and screws have been invented for use in joint surgery. In this study, screws made of allogenic sheep and xenogenic human bone were analyzed in a vital and dynamic sheep-model and compared to conventional titanium screws over a standard period of bone healing of 56 days with a constant applied extrusion force. Biomechanical analysis and histomorphological evaluation were performed. After 56 days of insertion xenogenic screws made of human bone showed significantly larger distance of extrusion of on average 173.8 μm compared to allogenic screws made of sheep bone of on average 27.8 and 29.95 μm of the titanium control group. Severe resorption processes with connective tissue interposition were found in the histomorphological analysis of the xenogenic screws in contrast to new bone formation and centripetal vascularization of the allogenic bone screw, as well as in processes of incorporation of the titanium control group. The study showed allogenic cortical bone screws as a substantial alternative to titanium screws with good biomechanical properties. In contrast to other reports a different result was shown for the xenogenic bone screws. They showed insufficient holding strength with confirmative histomorphological signs of degradation and insufficient osseointegration. Before common clinical use of xenogenic osteosynthetic material, further evaluation should be performed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. [The VB system: a new modular osteosynthesis material involving both screws and wires].

    PubMed

    Dubert, T; Valenti, P; Dinh, A; Osman, N

    2002-01-01

    VB is an osteosynthesis system for the stabilisation of small fragments, which combines the benefits of both wires and screws. It is a modular system comprising a threaded pin and a ring. The threaded pin is first positioned. Then a ring is grasped and opened by the progressive angulation of a screwdriver. Still anchored on the screwdriver, the ring slides easily on the pin. It is clamped on the pin by simply removing the screwdriver and the pin is then cut. This modular system includes 1.8 and 1.1 mm pins and different types of rings (threaded or non threaded, with or without collars). The system is easy to handle and can be introduced using an open or percutaneous technique, allowing compression or distraction. Our preliminary series, performed in accordance with National clinical trial protocol (Huriet) consisted of 50 cases in 24 patients (five women and 19 men) with an average age of 48 years, and a follow-up of more than six months. Fourteen cases of fractures (28 implants) were treated as emergencies (two radial heads, one capitellum, one trochlea of the humerus, seven distal radius fractures, one trapezium, two metacarpals) and 12 cases (22 implants) were elective cases: arthrodesis (one trapezo-metacarpal, one intermetacarpal, two interphalangeal, two carpal), non-union (six scaphoids, one phalangeal) and one phalangeal malunion. Hardware removal was performed in 16 cases. No implant failure has been detected. One case, a DIP arthrodesis, had a suspicion of sepsis which led to the removal of the implants at six weeks. The results of this study have convinced us of the merits of the system, which combines the advantages of both wires and screws. The system allows the user to perform either distraction or compression, and to adjust the force by hand. Compared to the fixed amount of compression produced by lag screws, this feature seems to be a real step forward.

  17. Initial dislocation structure and dynamic dislocation multiplication in Mo single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsiung, L M; Lassila, D H

    Initial dislocation structure in annealed high-purity Mo single crystals and deformation substructure in a crystal subjected to 1% compression have been examined and studied in order to investigate dislocation multiplication mechanisms in the early stages of plastic deformation. The initial dislocation density is in a range of 10{sup 6} {approx} 10{sup 7} cm{sup -2}, and the dislocation structure is found to contain many grown-in superjogs along dislocation lines. The dislocation density increases to a range of 10{sup 8} {approx} 10{sup 9} cm{sup -2}, and the average jog height is also found to increase after compressing for a total strain ofmore » 1%. It is proposed that the preexisting jogged screw dislocations can act as (multiple) dislocation multiplication sources when deformed under quasi-static conditions. Both the jog height and length of link segment (between jogs) can increase by stress-induced jog coalescence, which takes place via the lateral migration (drift) of superjogs driven by unbalanced line-tension partials acting on link segments of unequal lengths. Applied shear stress begins to push each link segment to precede dislocation multiplication when link length and jog height are greater than critical lengths. This dynamic dislocation multiplication source is subsequently verified by direct simulations of dislocation dynamics under stress to be crucial in the early stages of plastic deformation in Mo single crystals.« less

  18. Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

    PubMed

    Kashayi-Chowdojirao, Sreekanth; Vallurupalli, Aashish; Chilakamarri, Vijay Krishna; Patnala, Chandrasekhar; Chodavarapu, Lalith Mohan; Kancherla, Nageswara Rao; Khazi Syed, Asif Hussain

    2017-11-01

    Non-union humeral shaft fractures are seen frequently in clinical practice at about 2-10% in conservative management and 30% in surgically operated patients. Osteosynthesis using dynamic compression plate (DCP), intramedullary nailing, locking compression plate (LCP), Ilizarov technique along with bone grafting have been reported previously. In cases of prior failed plate-screw osteosynthesis the resultant osteopenia, cortical defect, bone loss, scalloping around screws and metallosis, make the management of non-union more complicated. Fibular graft as an intramedullary strut is useful in these conditions by increasing screw purchase, union and mechanical stability. This study is a retrospective and prospective follow up of revision plating along with autologous non-vascularised intramedullary fibular strut graft (ANVFG) for humeral non-unions following failed plate osteosynthesis. Seventy eight cases of nonunion humeral shaft fractures were managed in our institute between 2008 and 2015. Of these, 57 cases were failed plate osteosynthesis, in which 15 cases were infected and 42 cases were noninfected. Out of the 78 cases, bone grafting was done in 55 cases. Fibular strut graft was used in 22 patients, of which 4 cases were of primary nonunion with osteoporotic bone. Applying the exclusion criteria of infection and inclusion criteria of failed plate osteosynthesis managed with revision plating using either LCP or DCP and ANVFG, 17 cases were studied. The mean age of the patients was 40.11 yrs (range: 26-57 yrs). The mean duration of non-union was 4.43 yrs (range: 0.5-14 yrs). The mean follow-up period was 33.41 months (range: 12-94 months). The average length of fibula was 10.7 cm (range: 6-15 cm). Main outcome measurements included bony union by radiographic assessment and pre- and postoperative functional evaluation using the DASH (Disabilities of the Arm, Shoulder and Hand) score. Results: Sixteen out of 17 fractures united following revision plating and fibular strut grafting. Average time taken for union was 3.5 months (range: 3-5 months). Complications included one each of implant failure with bending, transient radial nerve palsy and transient ulnar nerve palsy. No case had infection, graft site morbidity or peroneal nerve palsy. Functional assessment by DASH score improved from 59.14 (range: 43.6-73.21) preoperatively to 23.39 (range: 8.03-34.2) postoperatively (p = 0.0003). Conclusion: The results of our study indicate that revision plating along with ANVFG is a reliable option in humeral diaphyseal non-unions with failed plate-screw osteosynthesis providing adequate screw purchase, mechanical stability and high chances of union with good functional outcome.

  19. Time-elapsed screw insertion with microCT imaging.

    PubMed

    Ryan, M K; Mohtar, A A; Cleek, T M; Reynolds, K J

    2016-01-25

    Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    PubMed Central

    Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    Background It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. Methodology/Principal Findings After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were randomly divided into three groups. The conventional pedicle screw (CPS) was inserted directly into vertebrae in CPS group; PMMA was injected prior to insertion of CPS in PMMA-PS group; and the EPS was inserted in EPS group. Sheep were killed and biomechanical tests, micro-CT analysis and histological observation were performed at both 6 and 12 weeks post-operation. At 6-week and 12-week, screw stabilities in EPS and PMMA-PS groups were significantly higher than that in CPS group, but there were no significant differences between EPS and PMMA-PS groups at two study periods. The screw stability in EPS group at 12-week was significantly higher than that at 6-week. The bone trabeculae around the expanding anterior part of EPS were more and denser than that in CPS group at 6-week and 12-week. PMMA was found without any degradation and absorption forming non-biological “screw-PMMA-bone” interface in PMMA-PS group, however, more and more bone trabeculae surrounded anterior part of EPS improving local bone quality and formed biological “screw-bone” interface. Conclusions/Significance EPS can markedly enhance screw stability with a similar effect to the traditional method of screw augmentation with PMMA in initial surgery in osteoporosis. EPS can form better biological interface between screw and bone than PMMA-PS. In addition, EPS have no risk of thermal injury, leakage and compression caused by PMMA. We propose EPS has a great application potential in augmentation of screw stability in osteoporosis in clinic. PMID:24086381

  1. End Restraints for Impact-Energy-Absorbing Tube Specimens

    NASA Technical Reports Server (NTRS)

    Farley, G. L.; Modlin, J. T.

    1985-01-01

    Inexpensive device developed that eliminates tipping problem without affecting crushing process. Device consists of soft sponge-rubber insert approximately 0.5 inches (1.3 centimeters) thick, cut to same diameter as internal diameter of tube specimen. Metal washer, slightly smaller than internal diameter of tube, placed on top of rubber insert. Screw passed through washer and rubber insert and threaded into base of test machine. As screw tightened against washer, rubber insert compressed and expands radially. Radial expansion applies pressure against internal wall of tube specimen, which provides sufficient support to tube to prevent tipping.

  2. Bilateral simultaneous femoral neck and shafts fractures - a case report.

    PubMed

    Sadeghifar, Amirreza; Saied, Alireza

    2014-10-01

    Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression plate and both necks were fixed using 6.5 mm cannulated screws. Femur fixation on one side was converted to retrograde nailing because of plate failure. Both neck fractures healed uneventfully. In spite of rarity of concomitant fractures of femoral neck and shaft, this injury must be approached carefully demanding especial attention and careful device selection.

  3. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    PubMed

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard titanium screws (3701 ± 1228 vs. 3751 ± 1614 load cycles, p = 0.89). PMMA cement augmentation of CF/PEEK pedicle screws furthermore significantly increased the mean number of load cycles until loosening by 1.63-fold (5100 ± 1933 in augmented vs. 3130 ± 2132 in nonaugmented CF/PEEK screws, p = 0.015). In addition, angular screw motion assessed by stress fluoroscopy was significantly smaller in augmented than in nonaugmented CF/PEEK screws before as well as after failure. Using nonmetallic CF/PEEK instead of standard titanium as pedicle screw material did not affect screw loosening in the chosen test setup, whereas cement augmentation enhanced screw anchorage of CF/PEEK screws. While comparable to titanium screws in terms of screw loosening, radiolucent CF/PEEK pedicle screws offer the significant advantage of not interfering with postoperative imaging and radiotherapy. These slides can be retrieved under Electronic Supplementary Material.

  4. Implant abutment deformation during prosthetic cylinder screw tightening: an in vitro study.

    PubMed

    Neto, Rafael Tobias Moretti; Moura, Marcio Silva; Souza, Edson Antonio Capello; Rubo, José Henrique

    2009-01-01

    Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Strain gauges were bonded to the sides of five standard abutments that had machined palladium-silver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 microepsilon. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 microepsilon (mean: 173.298 microepsilon) and from -5.62638 to -383.86 microepsilon (mean: 200.474 microepsilon) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time.

  5. Accuracy of a dynamic surgical guidance probe for screw insertion in the cervical spine: a cadaveric study.

    PubMed

    Dixon, Daniel; Darden, Bruce; Casamitjana, Jose; Weissmann, Karen A; Cristobal, San; Powell, David; Baluch, Daniel

    2017-04-01

    A fresh frozen cadaver study was conducted. To report the cortical breach rate using the dynamic surgical guidance (DSG) probe versus traditional freehand technique for cervical lateral mass, cervical pedicle and cervical laminar screws. Nine male fresh frozen cadaveric torsos were utilized for this study. Each investigator was assigned three specimens that were randomized by fixation point, side and order of technique for establishing a screw pilot hole. The technique for screw hole preparation utilized was either a DSG probe in the "on" mode or in the "off" mode using a freehand technique popularized by Lenke et al. Levels instrumented included C1 lateral mass, C2 pedicle screws and lamina screws, and C6-T1 pedicle screws. Fluoroscopy and other navigational assistance were not used for screw hole preparation or screw insertion. All specimens were CT imaged following insertion of all screws. A senior radiologist evaluated all scans and determined that a misplaced screw was a breach of ≥2 mm. A total of 104 drillings were performed, 52 with DSG and 52 without DSG There were 68 total pedicle drillings, 34 in each group. There were 18 drillings in the lamina and lateral mass. There was no significant difference between surgeons or between the left and right side. All breaches were in the pedicle, and none in the lamina or lateral mass. The breach rate for PG "on" was 6/68 = 8.96% (95% CI 3.69, 19.12%). The breach rate for PG "off" was 20/68 = 29.41% (95% CI 19.30, 41.87%). Of the 20 pedicle breaches in the non-DSG group, 7 were lateral and superior, 8 were lateral, 4 medial and 1 inferior. Of the six pedicle breaches in the DSG group, two were lateral/superior, two were lateral and two were medial in the pedicle. The dynamic surgical guidance probe is a safe tool to assist the surgeon with screw placement in the cervical spine. Additionally, the DSG potentially avoids the cumulative risks associated with fluoroscopy and provides real-time feedback to the surgeon allowing correction at the time of breach. Level of evidence Level IV.

  6. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

    PubMed

    Lewis, Gregory S; Caroom, Cyrus T; Wee, Hwabok; Jurgensmeier, Darin; Rothermel, Shane D; Bramer, Michelle A; Reid, John Spence

    2015-10-01

    The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.

  7. "Turn-of-the-Nut" Method Is Not Appropriate for Use in Cancellous Bone.

    PubMed

    Ryan, Melissa K; Mohtar, Aaron A; Costi, John J; Reynolds, Karen J

    2015-11-01

    The level to which bone screws are tightened is determined subjectively by the operating surgeon. It is likely that the tactile feedback that surgeons rely on is based on localized tissue yielding, which may predispose the screw-bone interface to failure. A limited number of studies have investigated the ratio between clinical tightening torque and stripping torque. The purpose of this study was to measure, for the first time, the ratio between yield torque (T yield) and stripping torque (T max) during screw insertion into the cancellous bone and to compare these torques with clinical levels of tightening reported in the literature. Additionally, a rotational limit was investigated as a potential end point for screw insertion in cancellous bone. A 6.5-mm outer diameter commercial cancellous bone screw was inserted into human femoral head specimens (n = 89). Screws were inserted to failure, while recording insertion torque, compression under the screw head, and rotation angle. The median, interquartile ranges, and coefficient of variation were calculated for each of the following parameters: T yield, T max, T yield/T max, slope, T plateau, and rotation angle. The median ratio of T yield/T max and rotation angle was 85.45% and 96.5 degrees, respectively. The coefficient of variation was greatest for the rotation angle compared with the ratio of T yield/T max (0.37 vs. 0.12). The detection of yield may be a more precise method than the rotation angle in cancellous bone; however, bone-screw constructs that exhibit a T yield close to T max may be more susceptible to stripping during insertion. Future work can identify factors that influence the ratio of T yield/T max may help to reduce the incidence of screw stripping.

  8. Dynamic nature of abutment screw retightening: finite element study of the effect of retightening on the settling effect.

    PubMed

    Bulaqi, Haddad Arabi; Mousavi Mashhadi, Mahmoud; Safari, Hamed; Samandari, Mohammad Mahdi; Geramipanah, Farideh

    2015-05-01

    A fundamental problem in fully understanding the dynamic nature of screw loosening is lack of recognition of the entire process of screw tightening and retightening. The purpose of this study was to explain the dynamic nature of abutment screw retightening by using finite element methods to investigate the effect of the coefficient of friction and retightening on the settling effect. Precise computer models were designed of a Straumann dental implant, a directly attached crown, an abutment screw, and the bone surrounding the implant. All threaded interfaces were designed with a spiral thread helix with a specific coefficient of static and kinetic friction, and the surfaces were characterized as fine, regular, and rough. Abaqus software was used for dynamic simulation, which involved applying rotational displacement to the abutment screw and torque controlling during the steps of tightening, relaxation, retightening, and second relaxation and at different coefficients of friction. The obtained torque and preload values were compared to the predicted values. When surfaces changed from fine to rough, the remaining torque and preload decreased, and the settling effect increased. Upon retightening, the remaining torque and preload increased, and the settling effect also decreased. The reduction of the coefficient of friction contributes to increases in the preload and decreases in the settling effect. Retightening reduced the settling effect and had an insignificant effect on the preload. At high coefficients of friction, the retightening effect was intensified. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Thermodynamic performance of multi-stage gradational lead screw vacuum pump

    NASA Astrophysics Data System (ADS)

    Zhao, Fan; Zhang, Shiwei; Sun, Kun; Zhang, Zhijun

    2018-02-01

    As a kind of dry mechanical vacuum pump, the twin-screw vacuum pump has an outstanding pumping performance during operation, widely used in the semiconductor industry. Compared with the constant lead screw (CLS) vacuum pump, the gradational lead screw (GLS) vacuum pump is more popularly applied in recent years. Nevertheless, not many comparative studies on the thermodynamic performance of GLS vacuum pump can be found in the literature. Our study focuses on one type of GLS vacuum pump, the multi-stage gradational lead screw (MGLS) vacuum pump, gives a detailed description of its construction and illustrates it with the drawing. Based on the structural analysis, the thermodynamic procedure is divided into four distinctive processes, including sucking process, transferring (compressing) process, backlashing process and exhausting process. The internal mechanism of each process is qualitatively illustrated and the mathematical expressions of seven thermodynamic parameters are given under the ideal situation. The performance curves of MGLS vacuum pump are plotted by MATLAB software and compared with those of the CLS vacuum pump in the same case. The results can well explain why the MGLS vacuum pump has more favorable pumping performance than the CLS vacuum pump in saving energy, reducing noise and heat dissipation.

  10. Numerical Simulation of the Working Process in the Twin Screw Vacuum Pump

    NASA Astrophysics Data System (ADS)

    Lu, Yang; Fu, Yu; Guo, Bei; Fu, Lijuan; Zhang, Qingqing; Chen, Xiaole

    2017-08-01

    Twin screw vacuum pumps inherit the advantages of screw machinery, such as high reliability, stable medium conveying, small vibration, simple and compact structures, convenient operation, etc, which have been widely used in petrochemical and air industry. On the basis of previous studies, this study analyzed the geometric features of variable pitch of the twin screw vacuum pump such as the sealing line, the meshing line and the volume between teeth. The mathematical model of numerical simulation of the twin screw vacuum pump was established. The leakage paths of the working volume including the sealing line and the addendum arc were comprehensively considered. The corresponding simplified geometric model of leakage flow was built up for different leak paths and the flow coefficients were calculated. The flow coefficient value range of different leak paths was given. The results showed that the flow coefficient of different leak paths can be taken as constant value for the studied geometry. The analysis of recorded indicator diagrams showed that the increasing rotational speed can dramatically decrease the exhaust pressure and the lower rotational speed can lead to over-compression. The pressure of the isentropic process which was affected by leakage was higher than the theoretical process.

  11. Study of Bulk and Elementary Screw Dislocation Assisted Reverse Breakdown in Low-Voltage (< 250 V) 4H-SiC p(sup +)n Junction Diodes--Part II: Dynamic Breakdown Properties. Part 2; Dynamic Breakdown Properties

    NASA Technical Reports Server (NTRS)

    Neudeck, Philip G.; Fazi, Christian

    1999-01-01

    This paper outlines the dynamic reverse-breakdown characteristics of low-voltage (<250 V) small-area <5 x 10(exp -4) sq cm 4H-SiC p(sup +)n diodes subjected to nonadiabatic breakdown-bias pulsewidths ranging from 0.1 to 20 microseconds. 4H-SiC diodes with and without elementary screw dislocations exhibited positive temperature coefficient of breakdown voltage and high junction failure power densities approximately five times larger than the average failure power density of reliable silicon pn rectifiers. This result indicates that highly reliable low-voltage SiC rectifiers may be attainable despite the presence of elementary screw dislocations. However, the impact of elementary screw dislocations on other more useful 4H-SiC power device structures, such as high-voltage (>1 kV) pn junction and Schottky rectifiers, and bipolar gain devices (thyristors, IGBT's, etc.) remains to be investigated.

  12. [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

    PubMed

    Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M

    2017-12-01

    In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial for stability.

  13. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    PubMed

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  14. Double throat pressure pulsation dampener for oil-free screw compressors

    NASA Astrophysics Data System (ADS)

    Lucas, Michael J.

    2005-09-01

    This paper describes a recent invention at Ingersoll-Rand for reducing the pressure pulsations in an oil-free screw compressor. Pressure pulsation is a term used in the air compressor industry to describe the rapid change in pressure with time measured in the downstream piping of the air compressor. The pulsations are due to the rapid opening and closing of the screws as the compressed air is eject from the compressor into the piping system. The pulsations are known to produce excessive noise levels and high levels of vibration in the piping system. Reducing these pulsations is critical to achieving a quiet running compressor. This paper will describe the methodology used to analyze the data and show both computational and experimental results achieved using the pulsation dampener. A patent for this design has been filed with the US patent office.

  15. Jet propulsion for airplanes

    NASA Technical Reports Server (NTRS)

    Buckingham, Edgar

    1924-01-01

    This report is a description of a method of propelling airplanes by the reaction of jet propulsion. Air is compressed and mixed with fuel in a combustion chamber, where the mixture burns at constant pressure. The combustion products issue through a nozzle, and the reaction of that of the motor-driven air screw. The computations are outlined and the results given by tables and curves. The relative fuel consumption and weight of machinery for the jet, decrease as the flying speed increases; but at 250 miles per hour the jet would still take about four times as much fuel per thrust horsepower-hour as the air screw, and the power plant would be heavier and much more complicated. Propulsion by the reaction of a simple jet can not compete with air screw propulsion at such flying speeds as are now in prospect.

  16. Note: A micro-perfusion system for use during real-time physiological studies under high pressure

    NASA Astrophysics Data System (ADS)

    Maltas, Jeff; Long, Zac; Huff, Alison; Maloney, Ryan; Ryan, Jordan; Urayama, Paul

    2014-10-01

    We construct a micro-perfusion system using piston screw pump generators for use during real-time, high-pressure physiological studies. Perfusion is achieved using two generators, with one generator being compressed while the other is retracted, thus maintaining pressurization while producing fluid flow. We demonstrate control over perfusion rates in the 10-μl/s range and the ability to change between fluid reservoirs at up to 50 MPa. We validate the screw-pump approach by monitoring the cyanide-induced response of UV-excited autofluorescence from Saccharomyces cerevisiae under pressurization.

  17. Note: A micro-perfusion system for use during real-time physiological studies under high pressure.

    PubMed

    Maltas, Jeff; Long, Zac; Huff, Alison; Maloney, Ryan; Ryan, Jordan; Urayama, Paul

    2014-10-01

    We construct a micro-perfusion system using piston screw pump generators for use during real-time, high-pressure physiological studies. Perfusion is achieved using two generators, with one generator being compressed while the other is retracted, thus maintaining pressurization while producing fluid flow. We demonstrate control over perfusion rates in the 10-μl/s range and the ability to change between fluid reservoirs at up to 50 MPa. We validate the screw-pump approach by monitoring the cyanide-induced response of UV-excited autofluorescence from Saccharomyces cerevisiae under pressurization.

  18. Design and application of electromechanical actuators for deep space missions

    NASA Technical Reports Server (NTRS)

    Haskew, Tim A.; Wander, John

    1993-01-01

    During the period 8/16/92 through 2/15/93, work has been focused on three major topics: (1) screw modeling and testing; (2) motor selection; and (3) health monitoring and fault diagnosis. Detailed theoretical analysis has been performed to specify a full dynamic model for the roller screw. A test stand has been designed for model parameter estimation and screw testing. In addition, the test stand is expected to be used to perform a study on transverse screw loading.

  19. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.

    PubMed

    Zhang, Ya-Kui; Wei, Hung-Wen; Lin, Kang-Ping; Chen, Wen-Chuan; Tsai, Cheng-Lun; Lin, Kun-Jhih

    2016-06-01

    Locking plate fixation for proximal humeral fractures is a commonly used device. Recently, plate breakages were continuously reported that the implants all have a mixture of holes allowing placement of both locking and non-locking screws (so-called combi plates). In commercialized proximal humeral plates, there still are two screw hole styles included "locking and dynamic holes separated" and "locking hole only" configurations. It is important to understand the biomechanical effect of different screw hole style on the stress distribution in bone plate. Finite element method was employed to conduct a computational investigation. Three proximal humeral plate models with different screw hole configurations were reconstructed depended upon an identical commercialized implant. A three-dimensional model of a humerus was created using process of thresholding based on the grayscale values of the CT scanning of an intact humerus. A "virtual" subcapital osteotomy was performed. Simulations were performed under an increasing axial load. The von Mises stresses around the screw holes of the plate shaft, the construct stiffness and the directional displacement within the fracture gap were calculated for comparison. The mean value of the peak von Mises stresses around the screw holes in the plate shaft was the highest for combi hole design while it was smallest for the locking and dynamic holes separated design. The stiffness of the plate-bone construct was 15% higher in the locking screw only design (132.6N/mm) compared with the combi design (115.0N/mm), and it was 4% higher than the combi design for the locking and dynamic holes separated design (119.5N/mm). The displacement within the fracture gap was greatest in the combi hole design, whereas it was smallest for the locking hole only design. The computed results provide a possible explanation for the breakages of combi plates revealed in clinical reports. The locking and dynamic holes separated design may be a better configuration to reduce the risk of plate fracture. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Theoretical investigation of flash vaporisation in a screw expander

    NASA Astrophysics Data System (ADS)

    Vasuthevan, Hanushan; Brümmer, Andreas

    2017-08-01

    In the present study flash vaporisation of liquid injection in a twin screw expander for a Trilateral Flash Cycle (TFC) is examined theoretically. The TFC process comprises a pressure increase in the working fluid, followed by heating the liquid close to boiling point. The hot liquid is injected into the working chamber of a screw expander. During this process the pressure of the liquid drops below the saturation pressure, while the temperature of the liquid remains virtually constant. Hence the liquid is superheated and in a metastable state. The liquid jet seeks to achieve a stable state in thermodynamic equilibrium and is therefore partially vaporised. This effect is referred to as flash vaporisation. Accordingly, a two-phase mixture, consisting of vapour and liquid, exists in the working chamber. Thermodynamic simulations were carried out using water as the working fluid for representative screw expander geometry. The simulations presented are performed from two different aspects during the filling process of a screw expander. The first case is the vaporisation of the injected liquid in a state of thermodynamic equilibrium, whereby the two-phase mixture is treated entirely as a compressible and homogeneous gas. The second case considers flashing efficiency. It describes the quantity of flashed vapour and consists of a liquid and vapour domain. Both models are compared and analysed with respect to the operational behaviour of a screw expander.

  1. Influence of the implant abutment types and the dynamic loading on initial screw loosening

    PubMed Central

    Kim, Eun-Sook

    2013-01-01

    PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. PMID:23509006

  2. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.

    PubMed

    Estes, Chris; Rhee, Peter; Shrader, M Wade; Csavina, Kristine; Jacofsky, Marc C; Jacofsky, David J

    2008-01-01

    The purpose of this study was to compare the biomechanical properties of a contoured locking plate instrumented with either an all-locked or hybrid locked/nonlocked screw construct in a proximal metaphyseal fracture of the tibia (AO 41-A3.2). A standardized proximal metaphyseal wedge osteotomy (AO 41-A3.2) was created in five pairs of cadaveric tibia. Each pair was randomly instrumented with either an all-locked or combination locked/nonlocked screw construct using a locked contoured periarticular plate (Peri-Loc periarticular locked plating system, Smith & Nephew, Memphis, TN). Vertical subsidence (irreversible deformation) and deflection (reversible deformation) in each pair were analyzed and compared. Load to failure, defined by complete fracture gap closure, was also determined. There was no statistically significant difference in vertical subsidence (P = 0.19) or deflection (P = 0.19) of the proximal tibia between the all-locked and combination locked/nonlocked screw construct with increasing levels of cyclical axial load from 200 to 1200 N. Failure occurred at a mean value of 2160 N in the locked group and 1760 N in the hybrid group (P = 0.19); the failure mode was plate bending in all specimens. The results indicate that the use of compression screws with locked screws in this particular construct allows a similar amount of irreversible and reversible deformation in response to an axial load when compared to an all-locked screw construct. This suggests that there is no statistically significant difference in the stability in fixation between the two methods, allowing the surgeon the freedom to choose the appropriate screw combination unique to each fracture.

  3. Comparison of 2 kinds of pedicle screws in primary spinal instrumentation: biomechanical and interfacial evaluations in sheep vertebrae in vitro.

    PubMed

    Liu, Da; Zhang, Yi; Lei, Wei; Wang, Cai-ru; Xie, Qing-yun; Liao, Dong-fa; Jiang, Kai; Zhou, Jin-song; Zhang, Bo; Pan, Xian-ming

    2014-04-01

    Expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) were inserted in sheep vertebrae in vitro and were evaluated by performing biomechanical tests, radiographic examinations and histological observations. The objective of the study was to compare the biomechanical and interfacial performances of EPS and PMMA-PS in sheep lumbar vertebrae in vitro. It is a great challenge for orthopedic surgeons performing transpedicular fixation in the osteoporotic spine. It was reported that either the EPS or PMMA-PS could increase the screw stability. However, there are no studies comparing the 2 kinds of screws especially in primary spinal instrumentation. A total of 60 sheep lumbar vertebrae were randomly divided into 3 groups. A pilot hole was made in advance in all samples using the same method. Thereafter, the conventional pedicle screw (CPS) was inserted directly into the pilot hole in the CPS group; the hole in PMMA-PS group was first filled with polymethylmethacrylate (PMMA; 1.0 mL) and then inserted with CPS; and the EPS was inserted directly into the vertebrae in EPS group. After a period of 24 hours, biomechanical tests were performed to evaluate screw stability, and x-ray examination, micro-computerized tomography analysis, and histologic observation were performed to evaluate the interface between screw and bone. Compared with the stability of CPS, those of EPS and PMMA-PS were significantly enhanced. However, no significant differences were detected between the stabilities of EPS and PMMA-PS. The PMMA surrounding the screw blocked direct contact between bone and screw and formed a "screw-PMMA-bone" interface in the PMMA-PS group. There was a "screw-bone" interface in both CPS and EPS groups. Nevertheless, the expanded anterior part of EPS formed a claw-like structure pressing the surrounding bone trabeculae, which made the local bone tissue more compacted and denser than that in the CPS group. EPS can enhance the screw stability as markedly as the traditional PMMA-PS in primary surgery, and EPS can form a better immediate interface between screw and bone compared with PMMA-PS. EPS also can effectively avoid thermal injury, leakage, and compression caused by PMMA. A great feasibility was proved in this study to perform comparisons between the 2 kinds of pedicle screws in osteoporotic sheep vertebrae in vivo in the further research. In conclusion, we propose that EPS has a great application potential in augmentation of screw stability in the clinic.

  4. Magnetic Resonance Imaging Studies of Process Rheology

    DTIC Science & Technology

    1990-08-14

    a Twin - screw Extruder ................ 7 2.1.2 NMR Flow Imaging Studies ................................... 7U 2.2 Theoretical Modeling ...run at high production rates, mixed in a 50.8 mm fully intermeshing, co - rotating twin - screw off-line techniques of quality control may lead to very...Imaging Studies of............... A -1 Mixing in a Twin - Screw Extruder " B. "Stokesian Dynamics Simulation of Polyether-coated

  5. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    PubMed

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p < 0.01) and a significantly lower axial migration over cycles compared with LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p < 0.01) and a significantly higher relative movement (1.1 mm, SD 0.05, p < 0.01) compared with LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  6. Condylar buttress plate versus fixed angle condylar blade plate versus dynamic condylar screw for supracondylar intra-articular distal femoral fractures.

    PubMed

    Petsatodis, George; Chatzisymeon, Apostolos; Antonarakos, Petros; Givissis, Panagiotis; Papadopoulos, Pericles; Christodoulou, Anastasios

    2010-04-01

    To compare outcomes of 3 fixation techniques for intra-articular distal femoral fractures. Records of 59 men and 49 women aged 16 to 80 (mean, 47) years who underwent internal fixation for 116 type-C (complete intra-articular) distal femoral fractures were retrospectively reviewed. According to the AO classification, 25 fractures were type C1 (23 closed and 2 open), 71 type C2 (69 closed and 2 open), and 20 type C3 (16 closed and 4 open). Based on implant availability at the time, all surgeries were performed by a single surgeon using a condylar buttress plate (n=38), a fixed angle (95 degrees) condylar blade plate (n=24), or a dynamic condylar screw (n=54). The mean follow-up period was 11 (range, 4-19) years. At the latest follow-up, functional outcome was classified according to Schatzker and Lambert criteria. Functional outcomes were excellent in 64 (55%) of the fractures, good in 37 (32%), moderate in 9 (8%), and poor in 6 (5%). Outcomes in patients treated by the dynamic condylar screw were significantly superior to those treated by the condylar buttress plate (p=0.016) or condylar blade plate (p=0.001). Good-to-excellent results were achieved in 96% vs 84% vs 71% of these patients, respectively. Complication rates were lower in the dynamic condylar screw group than the other 2 groups (pseudarthrosis, 5% vs 11% vs 25%; varus deformity, 4% vs 26% vs 25%; knee stiffness, 0% vs 5% vs 8%, respectively). No implant failure was encountered. Dynamic condylar screw fixation for distal femoral fractures achieves better functional outcomes and lower complication rates.

  7. A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation

    PubMed Central

    Sun, Haolin; Liu, Chun; Liu, Huiling; Bai, Yanjie; Zhang, Zheng; Li, Xuwen; Li, Chunde; Yang, Huilin; Yang, Lei

    2017-01-01

    Polymethyl methacrylate (PMMA)-augmented cannulated pedicle-screw fixation has been routinely performed for the surgical treatment of lumbar degenerative diseases. Despite its satisfactory clinical outcomes and prevalence, problems and complications associated with high-strength, stiff, and nondegradable PMMA have largely hindered the long-term efficacy and safety of pedicle-screw fixation in osteoporotic patients. To meet the unmet need for better bone cement for cannulated pedicle-screw fixation, a new injectable and biodegradable nanocomposite that was the first of its kind was designed and developed in the present study. The calcium phosphate-based nanocomposite (CPN) exhibited better anti-pullout ability and similar fluidity and dispersing ability compared to clinically used PMMA, and outperformed conventional calcium phosphate cement (CPC) in all types of mechanical properties, injectability, and biodegradability. In term of axial pullout strength, the CPN-augmented cannulated screw reached the highest force of ~120 N, which was higher than that of PMMA (~100 N) and CPC (~95 N). The compressive strength of the CPN (50 MPa) was three times that of CPC, and the injectability of the CPN reached 95%. In vivo tests on rat femur revealed explicit biodegradation of the CPN and subsequent bone ingrowth after 8 weeks. The promising results for the CPN clearly suggest its potential for replacing PMMA in the application of cannulated pedicle-screw fixation and its worth of further study and development for clinical uses. PMID:28490878

  8. Non-symmetric approach to single-screw expander and compressor modeling

    NASA Astrophysics Data System (ADS)

    Ziviani, Davide; Groll, Eckhard A.; Braun, James E.; Horton, W. Travis; De Paepe, M.; van den Broek, M.

    2017-08-01

    Single-screw type volumetric machines are employed both as compressors in refrigeration systems and, more recently, as expanders in organic Rankine cycle (ORC) applications. The single-screw machine is characterized by having a central grooved rotor and two mating toothed starwheels that isolate the working chambers. One of the main features of such machine is related to the simultaneous occurrence of the compression or expansion processes on both sides of the main rotor which results in a more balanced loading on the main shaft bearings with respect to twin-screw machines. However, the meshing between starwheels and main rotor is a critical aspect as it heavily affects the volumetric performance of the machine. To allow flow interactions between the two sides of the rotor, a non-symmetric modelling approach has been established to obtain a more comprehensive model of the single-screw machine. The resulting mechanistic model includes in-chamber governing equations, leakage flow models, heat transfer mechanisms, viscous and mechanical losses. Forces and moments balances are used to estimate the loads on the main shaft bearings as well as on the starwheel bearings. An 11 kWe single-screw expander (SSE) adapted from an air compressor operating with R245fa as working fluid is used to validate the model. A total of 60 steady-steady points at four different rotational speeds have been collected to characterize the performance of the machine. The maximum electrical power output and overall isentropic efficiency measured were 7.31 kW and 51.91%, respectively.

  9. [Cement augmentation on the spine : Biomechanical considerations].

    PubMed

    Kolb, J P; Weiser, L; Kueny, R A; Huber, G; Rueger, J M; Lehmann, W

    2015-09-01

    Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1-5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.

  10. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate constructs and the unlocked IM nail were significantly less with a 50% saw cut depth. Plate fixation was superior to IM nail fixation in limiting the opening of a simulated midtibial stress fracture, and anterior-posterior placement of the plate was an important variable for this construct. Results from these tests can help guide the selection of fixation hardware for patients requiring surgical treatment for a midtibial stress fracture. © 2016 The Author(s).

  11. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    PubMed

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p < 0.001). In addition, intact screws closer to the fracture required 2.8 times more removal torque than the outboard distal screw (p < 0.005). On average, the angle of rotation to peak torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  12. Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.

    PubMed

    Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung

    2010-01-01

    Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.

  13. The influence of distal screw length on the primary stability of volar plate osteosynthesis--a biomechanical study.

    PubMed

    Baumbach, Sebastian F; Synek, Alexander; Traxler, Hannes; Mutschler, Wolf; Pahr, Dieter; Chevalier, Yan

    2015-09-08

    Extensor tendon irritation is one of the most common complications following volar locking plate osteosynthesis (VLPO) for distal radius fractures. It is most likely caused by distal screws protruding the dorsal cortex. Shorter distal screws could avoid this, yet the influence of distal screw length on the primary stability in VLPO is unknown. The aim of this study was to compare 75 to 100% distal screw lengths in VLPO. A biomechanical study was conducted on 11 paired fresh-frozen radii. HRpQCT scans were performed to assess bone mineral density (BMD) and bone mineral content (BMC). The specimens were randomized pair-wise into two groups: 100% (group A) and 75% (group B) unicortical distal screw lengths. A validated fracture model for extra-articular distal radius fractures (AO-23 A3) was used. Polyaxial volar locking plates were mounted, and distal screws was inserted using a drill guide block. For group A, the distal screw tips were intended to be flush or just short of the dorsal cortex. In group B, a target screw length of 75% was calculated. The specimens were tested to failure using a displacement-controlled axial compression test. Primary biomechanical stability was assessed by stiffness, elastic limit, and maximum force as well as with residual tilt, which quantified plastic deformation. Nine specimens were tested successfully. BMD and BMC did not differ between the two groups. The mean distal screw length of group A was 21.7 ± 2.6 mm (range: 16 to 26 mm), for group B 16.9 ± 1.9 mm (range: 12 to 20 mm). Distal screws in group B were on average 5.6 ± 0.9 mm (range: 3 to 7 mm) shorter than measured. No significant differences were found for stiffness (706 ± 103 N/mm vs. 660 ± 124 N/mm), elastic limit (177 ± 25 N vs. 167 ± 36 N), maximum force (493 ± 139 N vs. 471 ± 149 N), or residual tilt (7.3° ± 0.7° vs. 7.1° ± 1.3°). The 75% distal screw length in VLPO provides similar primary stability to 100% unicortical screw length. This study, for the first time, provides the biomechanical basis to choose distal screws significantly shorter then measured.

  14. Volar fixed-angle plating of extra-articular distal radius fractures--a biomechanical analysis comparing threaded screws and smooth pegs.

    PubMed

    Weninger, Patrick; Dall'Ara, Enrico; Leixnering, Martin; Pezzei, Christoph; Hertz, Harald; Drobetz, Herwig; Redl, Heinz; Zysset, Philippe

    2010-11-01

    Distal radius fractures represent the most common fractures in adult individuals. Volar fixed-angle plating has become a popular modality for treating unstable distal radius fractures. Most of the plates allow insertion of either threaded locking screws or smooth locking pegs. To date, no biomechanical studies compare locking screws and pegs under axial and torsional loading. Ten Sawbones radii were used to simulate an AO/OTA A3 fracture. Volar fixed-angle plates (Aptus Radius 2.5, Medartis, Switzerland) with threaded locking screws (n = 5) or smooth locking pegs (n = 5) were used to fix the distal metaphyseal fragment. Each specimen was tested under axial compression and under torsional load with a servohydraulic testing machine. Qualitative parameters were recorded as well as axial and torsional stiffness, torsion strength, energy absorbed during monotonic loading and energy absorbed in one cycle. Axial stiffness was comparable between both groups (p = 0.818). If smooth pegs were used, a 17% reduction of torsional stiffness (p = 0.017) and a 12% reduction of minimum torque (p = 0.012) were recorded. A 12% reduction of energy absorbed (p = 0.013) during monotonic loading and unloading was recorded if smooth pegs were used. A 34% reduction of energy absorbed in one cycle (p < 0.007) was recorded if threaded screws were used. Sliding of the pegs out of the distal radius metaphyses of the synthetic bones was recorded at a mean torque of 3.80 Nm ± 0.19 Nm. No sliding was recorded if threaded screws were used. According to the results of this study using Sawbones, volar fixed-angle plates with threaded locking screws alone are mechanically superior to volar fixed-angle plates with smooth locking pegs alone under torsional loading.

  15. A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture.

    PubMed

    Laflamme, Mélissa; Belzile, Etienne L; Bédard, Luc; van den Bekerom, Michel P J; Glazebrook, Mark; Pelet, Stéphane

    2015-05-01

    To compare the clinical and radiographic outcome after stabilization of an acute syndesmosis rupture with either a static implant (a 3.5-mm metallic screw through 4 cortices) or a dynamic device (TightRope; Arthrex). Multicenter randomized double-blind controlled trial. Study realized in 5 trauma centers (2 level 1 and 3 level 2) in 2 countries. Seventy subjects admitted for an acute ankle syndesmosis rupture entered the study and were randomized into 2 groups (dynamic fixation = 34 and static fixation = 36). The 2 groups were similar regarding demographic, social, and surgical data. Sixty-five patients (dynamic = 33 and static = 32) completed the study and were available for analysis. Syndesmosis fixation in the static group was realized with a 4 cortices 3.5-mm cortical screw (Synthes) and in the dynamic group with 1 TightRope (Arthrex). Standardized rehabilitation process for the 2 groups: no weight bearing in a cast for 6 weeks and then rehabilitation without protection. Olerud-Molander score. Subjects with dynamic fixation achieved better clinical performances as described with the Olerud-Molander scores at 3 (68.8 vs. 60.2, P = 0.067), 6 (84.2 vs. 76.8, P = 0.082), and 12 months (93.3 vs. 87.6, P = 0.046). We also observed higher American Orthopaedic Foot and Ankle Society scores at 3 months (78.6 vs. 70.6, P = 0.016), but these were not significant at 6 (87.1 vs. 83.8, P = 0.26) or 12 months (93.1 vs. 89.9, P = 0.26). Implant failure was higher in the screw group (36.1% vs. 0%, P < 0.05). Loss of reduction was observed in 4 cases in the static screw group (11.1% vs. 0%, P = 0.06). Dynamic fixation of acute ankle syndesmosis rupture with a dynamic device seems to result in better clinical and radiographic outcomes. The implant offers adequate syndesmotic stabilization without failure or loss of reduction, and the reoperation rate is significantly lower than with conventional screw fixation. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  16. Randomised controlled trial of the sliding hip screw versus X-Bolt Dynamic Hip Plating System for the fixation of trochanteric fractures of the hip in adults: a protocol study for WHiTE 4 (WHiTE4).

    PubMed

    Griffin, Xavier L; Achten, Juul; Sones, William; Cook, Jonathan; Costa, Matthew L

    2018-01-26

    Sliding hip screw fixation is well established in the treatment of trochanteric fractures of the hip. The X-Bolt Dynamic Hip Plating System builds on the successful design features of the sliding hip screw but differs in the nature of the fixation in the femoral head. A randomised pilot study suggested that the X-bolt Dynamic Hip Plating System might provide similar health-related quality of life while reducing the risk of revision surgery when compared with the sliding hip screw. This is the protocol for a multicentre randomised trial of sliding hip screw versus X-Bolt Dynamic Hip Plating System for patients 60 years and over treated for a trochanteric fracture of the hip. Multicentre, multisurgeon, parallel, two-arm, randomised controlled trial. Patients aged 60 years and older with a trochanteric hip fracture are potentially eligible. Participants will be randomly allocated on a 1:1 basis to either sliding hip screw or X-Bolt Dynamic Hip Plating System. Otherwise, all care will be in accordance with National Institute for Health and Care Excellence guidance. A minimum of 1128 patients will be recruited to obtain 90% power to detect a 0.075-point difference in EuroQol-5D health-related quality of life at 4 months postrandomisation. Secondary outcomes include mortality, residential status, revision surgery and radiographic measures. The treatment effect will be estimated using a two-sided t-test adjusted for age, gender and cognitive impairment based on an intention-to-treat analysis. National Research Ethics Committee approved this study on 5 February 2016 (16/WM/0001). The study is sponsored by the University of Oxford and funded through an investigator initiated grant by X-Bolt Orthopaedics. A manuscript for a high-impact peer-reviewed journal will be prepared, and the results will be disseminated to patients through local mechanisms at participating centres. ISRCTN92825709. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  18. Numerical estimation of deformation energy of selected bulk oilseeds in compression loading

    NASA Astrophysics Data System (ADS)

    Demirel, C.; Kabutey, A.; Herak, D.; Gurdil, G. A. K.

    2017-09-01

    This paper aimed at the determination of the deformation energy of some bulk oilseeds or kernels namely oil palm, sunflower, rape and flax in linear pressing applying the trapezoidal rule which is characterized by the area under the force and deformation curve.The bulk samples were measured at the initial pressing height of 60 mm with the vessel diameter of 60 mm where they were compressed under the universal compression machine at a maximum force of 200 kN and speed of 5 mm/min.Based on the compression test, the optimal deformation energy for recovering the oil was observed at a force of 163 kN where there was no seed/kernel cake ejection in comparison to the initial maximum force used particularly for rape and flax bulk oilseeds.This information is needed for analyzing the energy efficiency of the non-linear compression process involving a mechanical screw press or expeller.

  19. Mechanical aspects of a multidirectional, angular stable osteosynthesis system and comparison with four conventional systems.

    PubMed

    Gbara, Ali; Heiland, Max; Schmelzle, Rainer; Blake, Felix

    2008-04-01

    Following open reduction, internal fixation of fractures of the mandible is predominantly achieved using plates and screws. Today, a multitude of osteosynthesis systems are available on the market. One therapy modality, primarily developed for orthopaedic surgery, is using angular stable osteosynthesis plate systems. The dominating principle of these is the bond between screw and plate following insertion. This principle of an "internal fixateur" results in a more stable fixation of the fragments associated with less compression of the bone surfaces. A new multidirectional osteosynthesis system (TiFix=Smartlock, Hamburg - Germany) was modified to fit the maxillofacial region and compared with four other well established osteosynthesis systems developed by Mondial, Medicon, Synthes, Leibinger-Stryker, one of these (Unilock by Synthes) being also angular stable. The resistance to deformation in varying directions was investigated following fixation in four different materials. The TiFix system proved more resistant to deformation even when mounted with fewer screws than the non-angular stable systems. This system results in greater stability even when fewer screws are used. For the clinician this means smaller access incisions, less soft tissue trauma, better aesthetic results, decreased duration of operation and a reduction of costs.

  20. Deformation Analysis of the Main Components in a Single Screw Compressor

    NASA Astrophysics Data System (ADS)

    Liu, Feilong; Liao, Xueli; Feng, Quanke; Van Den Broek, Martijn; De Paepe, Michel

    2015-08-01

    The single screw compressor is used in many fields such as air compression, chemical industry and refrigeration. During operation, different gas pressures and temperatures applied on the components can cause different degrees of deformation, which leads to a difference between the thermally induced clearance and the designed clearance. However, limited research about clearance design is reported. In this paper, a temperature measurement instrument and a convective heat transfer model were described and used to establish the temperature of a single screw air compressor's casing, screw rotor and star wheel. 3-D models of these three main components were built. The gas force deformation, thermal- structure deformation and thermal-force coupling deformation were carried out by using a finite element simulation method. Results show that the clearance between the bottom of the groove and the top of star wheel is reduced by 0.066 mm, the clearance between the side of groove and the star wheel is reduced by 0.015 mm, and the clearance between the cylinder and the rotor is reduced by 0.01 mm. It is suggested that these deformations should be taken into account during the design of these clearances.

  1. Real-time particle size analysis using focused beam reflectance measurement as a process analytical technology tool for a continuous granulation-drying-milling process.

    PubMed

    Kumar, Vijay; Taylor, Michael K; Mehrotra, Amit; Stagner, William C

    2013-06-01

    Focused beam reflectance measurement (FBRM) was used as a process analytical technology tool to perform inline real-time particle size analysis of a proprietary granulation manufactured using a continuous twin-screw granulation-drying-milling process. A significant relationship between D20, D50, and D80 length-weighted chord length and sieve particle size was observed with a p value of <0.0001 and R(2) of 0.886. A central composite response surface statistical design was used to evaluate the effect of granulator screw speed and Comil® impeller speed on the length-weighted chord length distribution (CLD) and particle size distribution (PSD) determined by FBRM and nested sieve analysis, respectively. The effect of granulator speed and mill speed on bulk density, tapped density, Compressibility Index, and Flowability Index were also investigated. An inline FBRM probe placed below the Comil-generated chord lengths and CLD data at designated times. The collection of the milled samples for sieve analysis and PSD evaluation were coordinated with the timing of the FBRM determinations. Both FBRM and sieve analysis resulted in similar bimodal distributions for all ten manufactured batches studied. Within the experimental space studied, the granulator screw speed (650-850 rpm) and Comil® impeller speed (1,000-2,000 rpm) did not have a significant effect on CLD, PSD, bulk density, tapped density, Compressibility Index, and Flowability Index (p value > 0.05).

  2. Strain tuning of electronic properties of various dimension elemental tellurium with broken screw symmetry

    NASA Astrophysics Data System (ADS)

    Xue, Xiong-Xiong; Feng, Ye-Xin; Liao, Lei; Chen, Qin-Jun; Wang, Dan; Tang, Li-Ming; Chen, Keqiu

    2018-03-01

    We present a systematical study of atomic structures and electronic properties of various dimension tellurium (Te) with broken intrinsical screw symmetry by applying reasonable strain. It is demonstrated that (i) bulk trigonal Te has degenerate Weyl nodes around the H point near the Fermi energy, and this degeneracy will be broken by introducing the selenium (Se) atom through creating the inner unsymmetrical strain, instead of external shear strain. (ii) 2D structures of tetragonal Te (t-Te) and 1T-MoS2-like Te (1T-Te) show direct and indirect band gap, respectively. Under the uniform biaxial compressive (BC) strain, monolayer of t-Te shows the direct-to-indirect band gap transition, while 1T-Te monolayer has a band gap transition firstly from indirect to direct and then from direct to indirect. Their effective masses of hole and electron can be effectively tuned by BC strain. (iii) One-dimensional (1D) structures of single helix, triangular Te and hexagonal Te nanowires display the obvious quantum confinement effect on the band structure and different sensitivity to the effect of uniaxial compressive strain.

  3. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    PubMed

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. On damping of screw dislocation bending vibrations in dissipative crystal: limiting cases

    NASA Astrophysics Data System (ADS)

    Dezhin, V. V.

    2018-03-01

    The expression for the generalized susceptibility of the dislocation obtained earlier was used. The electronic drag mechanism of dislocations is considered. The study of small dislocation oscillations was limited. The contribution of the attenuation of low-frequency bending screw dislocation vibrations to the overall coefficient of dynamic dislocation drag in the long-wave and short-wave limits is calculated. The damping of short-wave bending screw dislocation vibrations caused by an external action of an arbitrary frequency has been investigated. The contribution of long-wave bending screw dislocation vibrations damping in the total drag coefficient at an arbitrary frequency is found.

  5. The strength of polyaxial locking interfaces of distal radius plates.

    PubMed

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  6. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    PubMed

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  7. Surface structural damage study in cortical bone due to medical drilling.

    PubMed

    Tavera R, Cesar G; De la Torre-I, Manuel H; Flores-M, Jorge M; Hernandez M, Ma Del Socorro; Mendoza-Santoyo, Fernando; Briones-R, Manuel de J; Sanchez-P, Jorge

    2017-05-01

    A bone's fracture could be produced by an excessive, repetitive, or sudden load. A regular medical practice to heal it is to fix it in two possible ways: external immobilization, using a ferule, or an internal fixation, using a prosthetic device commonly attached to the bone by means of surgical screws. The bone's volume loss due to this drilling modifies its structure either in the presence or absence of a fracture. To observe the bone's surface behavior caused by the drilling effects, a digital holographic interferometer is used to analyze the displacement surface's variations in nonfractured post-mortem porcine femoral bones. Several nondrilled post-mortem bones are compressed and compared to a set of post-mortem bones with a different number of cortical drillings. During each compression test, a series of digital interferometric holograms were recorded using a high-speed CMOS camera. The results are presented as pseudo 3D mesh displacement maps for comparisons in the physiological range of load (30 and 50 lbs) and beyond (100, 200, and 400 lbs). The high resolution of the optical phase gives a better understanding about the bone's microstructural modifications. Finally, a relationship between compression load and bone volume loss due to the drilling was observed. The results prove that digital holographic interferometry is a viable technique to study the conditions that avoid the surgical screw from loosening in medical procedures of this kind.

  8. An easy way to apply orthodontic extraction for impacted lower third molar compressing to the inferior alveolar nerve.

    PubMed

    Wang, Yong; He, Dongmei; Yang, Chi; Wang, Baoli; Qian, Wentao

    2012-04-01

    To study the results of an easy orthodontic extraction method for impacted lower third molar removal which had roots compressing to the inferior alveolar nerve (IAN). Forty patients were divided into two groups according to their desire. Orthodontic traction group (n=20) had brackets or mini bone screws on the antagonist maxillary molars as anchorage for orthodontic traction from 3 to 10 weeks until the roots' tip was away from the IAN, the tooth was then removed. Traditional extraction group (n=20) had the tooth removed immediately by the same surgeon. Post-operative results were compared between the two groups. All 20 patients in the orthodontic extraction group had their lower impacted third molar removed easily without lower lip numbness after surgery, while 5 patients in the traditional extraction group had transient IAN injury and went away 1 week later. There were no anchorage teeth and adjacent mandibular second molar loose or displacement. Application of orthodontic brackets or mini bone screws on the antagonist maxillary molars is an easy way for orthodontic extraction of impacted lower third molar with roots' tip compressed to the IAN. It is an effective way to avoid IAN injury during tooth extraction. Copyright © 2011 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Experiment of comparing coldformed steel shear connection using 2 self drilling screw and sikadur 31cf normal adhesive

    NASA Astrophysics Data System (ADS)

    Sumaidi; Suprobo, P.; Wahyuni, E. dan

    2018-01-01

    Screw connection is prefered used by apllicator because of it’s simple. Type of screw usually used is Self Drilling Screw (SDS). This type of screw will become fix as it’s screwed by the applicator until its head . almost all applicator able to make this connection and do not need some course or sertificate to become an applicator, does not like applicator of High Tension Bolt, HTB. But this type of connection has some disadvantages, for example it’s connection doest not suit to dynamic loading. the experiment results that galvalume material has Yeilding Force, fy = 580 Mpa and Ultimate Force, fu = 590 Mpa. Connection of 2 SDS screw vertically configured fail on about tension loading 6000 N less than horizontally configured that fail on about 7500 N. Displacement of 2 SDS screw vertically configure on about 0.6 mm less than horizontally one that fail on displacement 0.85 mm. For adhesive of Sikadur CF 31 connection fail on loading about 6000 N tension loading but its displacement is less than 0.5 mm when it fail, for 2 type of connection configured.

  10. Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.

    PubMed

    Juvonen, Tiina; Koistinen, Arto; Kröger, Heikki; Lappalainen, Reijo

    2012-09-27

    The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material. Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.

  11. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    PubMed

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.

  12. Quantifying the competing relationship between adduction range of motion and baseplate micromotion with lateralization of reverse total shoulder arthroplasty.

    PubMed

    Elwell, Josie; Choi, Joseph; Willing, Ryan

    2017-02-08

    Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) could improve functional outcomes and mitigate scapular notching, a commonly occurring complication of the procedure. However, resulting increases in torque at the bone-implant interface may negatively affect initial fixation of the glenoid-side component, especially if only two fixation screws can be placed. Shoulder-specific finite element (FE) models of four fresh-frozen cadaveric shoulders were constructed. Scapular geometry and material property distributions were derived from CT data. Generic baseplates with two and four fixation screws were virtually implanted, after which superiorly-oriented shear loads, accompanied by a compressive load, were applied incrementally further from the glenoid surface to simulate lateralization of the COR. Relationships between lateralization, adduction range of motion (ROM), the number of fixation screws and micromotion of the baseplate (initial implant fixation) were characterized. Lateralization significantly increases micromotion (p=0.015) and adduction ROM (p=0.001). Using two, versus four, baseplate fixation screws significantly increases micromotion (p=0.008). The effect of lateralization and the number of screws on adduction ROM and baseplate fixation is variable on a shoulder-specific basis. Trade-offs exist between functional outcomes, namely adduction ROM, and initial implant fixation and the negative effect of lateralization on implant fixation is amplified when only two fixation screws are used. The possibility of lateralizing the COR in order to improve functional outcomes of the procedure should be considered on a patient-specific basis accounting for factors such as availability and quality of bone stock. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Contribution of the xenograft bone plate-screw system in lumbar transpedicular stabilization: An in vivo study in dogs

    PubMed Central

    Sarigul, Sani; Salci, Hakan; Lekesiz, Huseyin; Dogan, Seref; Ozcan, Resat; Gorgul, Osman Sacit; Aksoy, Kaya

    2017-01-01

    Objectives: Xenograft bone plate-screws (XBPSs) can be alternative tools in lumbar transpedicular stabilization (TS). The aim of this study was to show biomechanical and histopathological contribution of the XBPSs system in lumbar TS. Materials and Methods: Fifteen (n = 15) hybrid dog and ten (n = 10) L2-4 cadaveric specimens were included in the study. The dogs were separated according to surgical techniques: L3 laminectomy and bilateral facetectomy (LBF) in Group I (experimental group [EG I] (n = 5), L3 LBF plus TS with metal plate-screws (MPSs) in Group II (EG II) (n = 5), and L3 LBF plus TS with XBPSs in Group III (EG III) (n = 5). The cadaveric specimens were separated to L2-4 intact in Group I (CG I), (n = 5), and L3 LBF in Group II (CG II), (n = 5). The dogs were sacrificed at the end of 3rd month, and their L2-4 spinal segments were en bloc removed and prepared as in control groups. Flexion, extension, left-right bending, rotation, and compression tests were applied to all segments. Stiffness values were calculated and analyzed statistically. All dog segments were evaluated histopathologically. Results: XBPS system showed a higher average stiffness values for left bending, extension, flexion, and compression compared to MPS, but these differences were not statistically meaningful. XBPS system had superiority to the fusion formation, as well. Conclusions: XBPSs provide stability and help the fusion formation, but this system does not have a biomechanical advantage over MPS system in TS. PMID:28761530

  14. Comparison of the stability of various internal fixators used in the treatment of osteochondritis dissecans--a mechanical model.

    PubMed

    Morelli, Moreno; Poitras, Philippe; Grimes, Valentine; Backman, David; Dervin, Geoffrey

    2007-04-01

    The purpose of this study was to determine what characteristics of fixation devices used in the treatment of osteochondritis dissecans (OCD) contribute to improved stability to resist shear loading. An OCD model was designed using rigid polyurethane foam. Each specimen consisted of two components, an osteochondral fragment and a corresponding defect. A total of 40 specimens were prepared and assigned to one of four groups: control (no extrinsic stabilizer); two 2-mm-diameter Kirschner wires (K-wires), 40 mm in length; one threaded washer and a 28-mm screw; and one threaded washer and a 38 mm screw. Each specimen was mounted onto an Iosipescu shear test fixture and subjected to shear loads at a pseudo-static displacement rate of 0.075 mm/s. All groups demonstrated some stability; controls were significantly less stable than all other groups. The group with the threaded washer and 38-mm screw demonstrated the greatest stability (p < 0.001), and no difference was noted between the K-wire and 28-mm screw groups. These results suggest that, in this OCD model, friction conferred some intrinsic stability to resist loads in shear. However, stability was improved with the use of long implants that compressed the fragments together.

  15. The dynamic natures of implant loading.

    PubMed

    Wang, Rui-Feng; Kang, Byungsik; Lang, Lisa A; Razzoog, Michael E

    2009-06-01

    A fundamental problem in fully understanding the dynamic nature of implant loading is the confusion that exists regarding the torque load delivered to the implant complex, the initial force transformation/stress/strain developed within the system during the implant complex assembly, and how the clamping forces at the interfaces and the preload stress impact the implant prior to any external loading. The purpose of this study was to create an accurately dimensioned finite element model with spiral threads and threaded bores included in the implant complex, positioned in a bone model, and to determine the magnitude and distribution of the force transformation/stress/strain patterns developed in the modeled implant system and bone and, thus, provide the foundational data for the study of the dynamic loading of dental implants prior to any external loading. An implant (Brånemark Mark III), abutment (CeraOne), abutment screw (Unigrip), and the bone surrounding the implant were modeled using HyperMesh software. The threaded interfaces between screw/implant and implant/bone were designed as a spiral thread helix assigned with specific coefficient of friction values. Assembly simulation using ABAQUS and LS-DYNA was accomplished by applying a 32-Ncm horizontal torque load on the abutment screw (Step 1), then decreasing the torque load to 0 Ncm to simulate the wrench removal (Step 2). The postscript data were collected and reviewed by HyperMesh. A regression analysis was used to depict the relationships between the torque load and the mechanical parameters. During the 32-Ncm tightening sequence, the abutment screw elongated 13.3 mum. The tightening torque generated a 554-N clamping force at the abutment/implant interface and a 522-N preload. The von Mises stress values were 248 MPa in the abutment at the abutment-implant interface, 765 MPa at the top of the screw shaft, 694 MPa at the bottom of the screw shaft, 1365 MPa in the top screw thread, and 21 MPa in the bone at the top of the implant-bone interface. This study also identified various characteristic isosurface stress patterns. The maximum stress magnitude to complete the von Mises stress joint pattern in the present model was 107 MPa during screw tightening, and was reduced to 104 MPa with removal of the wrench. Various specific stress patterns were identified within all elements of the implant complex during the assembly simulation. During the torque moment application, the abutment screw was elongated, and every 1.0-mum elongation of the screw was equivalent to a 47.9-N increase of the preload in the implant complex. The ideal index to determine the preload amount was the contact force at the interface between the screw threads and the threaded screw bore. The isosurface mode identified various characteristic stress patterns developed within the implant complex at the various interfaces during the assembly simulation. These patterns are the (1) spiral and ying-yang pattern of the XY stress, (2) spring, cap, clamping, and preload pattern of the ZZ stress, and (3) bone holding and joint pattern of the von Mises stress.

  16. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    NASA Astrophysics Data System (ADS)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  17. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    PubMed Central

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material. PMID:25551010

  18. Stress and temperature dependence of screw dislocation mobility in {alpha}-Fe by molecular dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, M. R.; Queyreau, S.; Marian, J.

    2011-11-01

    The low-temperature plastic yield of {alpha}-Fe single crystals is known to display a strong temperature dependence and to be controlled by the thermally activated motion of screw dislocations. In this paper, we present molecular dynamics simulations of (1/2)<111>{l_brace}112{r_brace} screw dislocation motion as a function of temperature and stress in order to extract mobility relations that describe the general dynamic behavior of screw dislocations in pure {alpha}-Fe. We find two dynamic regimes in the stress-velocity space governed by different mechanisms of motion. Consistent with experimental evidence, at low stresses and temperatures, the dislocations move by thermally activated nucleation and propagation ofmore » kink pairs. Then, at a critical stress, a temperature-dependent transition to a viscous linear regime is observed. Critical output from the simulations, such as threshold stresses and the stress dependence of the kink activation energy, are compared to experimental data and other atomistic works with generally very good agreement. Contrary to some experimental interpretations, we find that glide on {l_brace}112{r_brace} planes is only apparent, as slip always occurs by elementary kink-pair nucleation/propagation events on {l_brace}110{r_brace} planes. Additionally, a dislocation core transformation from compact to dissociated has been identified above room temperature, although its impact on the general mobility is seen to be limited. This and other observations expose the limitations of inferring or presuming dynamic behavior on the basis of only static calculations. We discuss the relevance and applicability of our results and provide a closed-form functional mobility law suitable for mesoscale computational techniques.« less

  19. In vivo measurement of spinal column viscoelasticity--an animal model.

    PubMed

    Hult, E; Ekström, L; Kaigle, A; Holm, S; Hansson, T

    1995-01-01

    The goal of this study was to measure the in vivo viscoelastic response of spinal motion segments loaded in compression using a porcine model. Nine pigs were used in the study. The animals were anaesthetized and, using surgical techniques, four intrapedicular screws were inserted into the vertebrae of the L2-L3 motion segment. A miniaturized servohydraulic exciter capable of compressing the motion segment was mounted on to the screws. In six animals, a loading scheme consisting of 50 N and 100 N of compression, each applied for 10 min, was used. Each loading period was followed by 10 min restitution with zero load. The loading scheme was repeated four times. Three animals were examined for stiffening effects by consecutively repeating eight times 50 N loading for 5 min followed by 5 min restitution with zero load. This loading scheme was repeated using a 100 N load level. The creep-recovery behavior of the motion segment was recorded continuously. Using non-linear regression techniques, the experimental data were used for evaluating the parameters of a three-parameter standard linear solid model. Correlation coefficients of the order of 0.85 or higher were obtained for the three independent parameters of the model. A survey of the data shows that the viscous deformation rate was a function of the load level. Also, repeated loading at 100 N seemed to induce long-lasting changes in the viscoelastic properties of the porcine lumbar motion segment.

  20. Relevance of Postoperative Magnetic Resonance Images in Evaluating Epidural Hematoma After Thoracic Fixation Surgery.

    PubMed

    Shin, Hong Kyung; Choi, Il; Roh, Sung Woo; Rhim, Seung Chul; Jeon, Sang Ryong

    2017-11-01

    It is difficult to evaluate the significant findings of epidural hematoma in magnetic resonance images (MRIs) obtained immediately after thoracic posterior screw fixation (PSF). Prospectively, immediate postoperative MRI was performed in 10 patients who underwent thoracic PSF from April to December 2013. Additionally, we retrospectively analyzed the MRIs from 3 patients before hematoma evacuation out of 260 patients who underwent thoracic PSF from January 2000 to March 2013. The MRI findings of 9 out of the 10 patients, consecutively collected after thoracic PSF, showed neurologic recovery with a well-preserved cerebrospinal fluid (CSF) space and no prominent hemorrhage. Even though there were metal artifacts at the level of the pedicle screws, the preserved CSF space was observed. In contrast, the MRI of 1 patient with poor neurologic outcome demonstrated a typical hematoma and slight spinal cord compression and reduced CSF space. In the retrospective analysis of the 3 patients who showed definite motor weakness in the lower extremities after their first thoracic fusion surgery and underwent hematoma evacuation, the magnetic resonance images before hematoma evacuation also revealed hematoma compressing the spinal cord and diminished CSF space. This study shows that epidural hematomas can be detected on MRI performed immediately after thoracic fixation surgery, despite metal artifacts and findings such as hematoma causing spinal cord compression. Loss of CSF space should be considered to be associated with neurologic deficit. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. An informational framework to predict reaction of constraints using a reciprocally connected knee model.

    PubMed

    Kim, Wangdo; Veloso, Antonio P; Araújo, Duarte; Vleck, Veronica; João, Filipa

    2015-01-01

    Researchers have used screw theory to describe the motion of the knee in terms of instantaneous axes of the knee (IAK). However, how geometric change to the dynamic alignment of IAK may affect stance phase of foot loading has not yet been fully explained. We have tested our informational framework through readily accessible benchmark data (Fregly et al. 2012): muscle contraction and ground reaction force are compounded into a wrench that is reciprocal to the IAK and resolved into component wrenches belonging to the reciprocal screw system. This revealed the special screw system that defines the freedom available to the knee and more precisely revealed how to measure this first order of freedom. After this step, we determined the reciprocal screw system, which involves the theory of equilibrium. Hence, a screw system of the first order will have a screw system of the fifth order as its reciprocal. We established a framework the estimation of reaction of constraints about the knee using a process that is simplified by the judicious generation of IAK for the first order of freedom in equilibrium.

  2. Structure, Energetics, and Dynamics of Screw Dislocations in Even n-Alkane Crystals.

    PubMed

    Olson, Isabel A; Shtukenberg, Alexander G; Hakobyan, Gagik; Rohl, Andrew L; Raiteri, Paolo; Ward, Michael D; Kahr, Bart

    2016-08-18

    Spiral hillocks on n-alkane crystal surfaces were observed immediately after Frank recognized the importance of screw dislocations for crystal growth, yet their structures and energies in molecular crystals remain ill-defined. To illustrate the structural chemistry of screw dislocations that are responsible for plasticity in organic crystals and upon which the organic electronics and pharmaceutical industries depend, molecular dynamics was used to examine heterochiral dislocation pairs with Burgers vectors along [001] in n-hexane, n-octane, and n-decane crystals. The cores were anisotropic and elongated in the (110) slip plane, with significant local changes in molecular position, orientation, conformation, and energy. This detailed atomic level picture produced a distribution of strain consistent with linear elastic theory, giving confidence in the simulations. Dislocations with doubled Burgers vectors split into pairs with elementary displacements. These results suggest a pathway to understanding the mechanical properties and failure associated with elastic and plastic deformation in soft crystals.

  3. PSEUDARTHROSIS OF THE SCAPHOID IN IMMATURE SKELETONS

    PubMed Central

    de Lemos, Marcelo Barreto; Bentes, Ádria Simone Ferreira; Neto, Miguel Flores do Amaral; Spinelli, Leandro de Freitas; Severo, Antônio Lourenço; Lech, Osvandré

    2015-01-01

    This paper presents a review of the literature on pseudarthrosis of the scaphoid in skeletally immature individuals, taking into consideration its epidemiology, diagnosis and treatment, as well as its controversies. Knowledge of this subject makes it possible for patients to be given appropriate treatment immediately. Pseudarthrosis of the scaphoid in skeletally immature patients is a rare condition that results from error or lack of diagnosis of a fracture. Thus, careful clinical and radiographic examination should be performed in order to confirm or rule out this diagnosis. Several treatment methods have been reported and have shown good results. These include conservative plaster cast treatment, bone graft without osteosynthesis, bone graft with Kirschner wires, percutaneous screws and bone graft with compression screws. The treatment performed depends on the characteristics of the pseudarthrosis and the surgeon's experience. PMID:27042636

  4. PSEUDARTHROSIS OF THE SCAPHOID IN IMMATURE SKELETONS.

    PubMed

    de Lemos, Marcelo Barreto; Bentes, Ádria Simone Ferreira; Neto, Miguel Flores do Amaral; Spinelli, Leandro de Freitas; Severo, Antônio Lourenço; Lech, Osvandré

    2012-01-01

    This paper presents a review of the literature on pseudarthrosis of the scaphoid in skeletally immature individuals, taking into consideration its epidemiology, diagnosis and treatment, as well as its controversies. Knowledge of this subject makes it possible for patients to be given appropriate treatment immediately. Pseudarthrosis of the scaphoid in skeletally immature patients is a rare condition that results from error or lack of diagnosis of a fracture. Thus, careful clinical and radiographic examination should be performed in order to confirm or rule out this diagnosis. Several treatment methods have been reported and have shown good results. These include conservative plaster cast treatment, bone graft without osteosynthesis, bone graft with Kirschner wires, percutaneous screws and bone graft with compression screws. The treatment performed depends on the characteristics of the pseudarthrosis and the surgeon's experience.

  5. Continuous twin screw granulation of controlled release formulations with various HPMC grades.

    PubMed

    Vanhoorne, V; Janssens, L; Vercruysse, J; De Beer, T; Remon, J P; Vervaet, C

    2016-09-25

    HPMC is a popular matrix former to formulate tablets with extended drug release. Tablets with HPMC are preferentially produced by direct compression. However, granulation is often required prior to tableting to overcome poor flowability of the formulation. While continuous twin screw granulation has been extensively evaluated for granulation of immediate release formulations, twin screw granulation of controlled release formulations including the dissolution behavior of the formulations received little attention. Therefore, the influence of the HPMC grade (viscosity and substitution degree) and the particle size of theophylline on critical quality attributes of granules (continuously produced via twin screw granulation) and tablets was investigated in the current study. Formulations with 20 or 40% HPMC, 20% theophylline and lactose were granulated with water at fixed process parameters via twin screw granulation. The torque was influenced by the viscosity and substitution degree of HPMC, but was not a limiting factor for the granulation process. An optimal L/S ratio was selected for each formulation based on the granule size distribution. The granule size distributions were influenced by the substitution degree and concentration of HPMC and the particle size of theophylline. Raman and UV spectroscopic analysis on 8 sieve fractions of granules indicated an inhomogeneous distribution of theophylline over the size fractions. However, this phenomenon was not correlated with the hydration rate or viscosity of HPMC. Controlled release of theophylline could be obtained over 24h with release profiles close to zero-order. The release of theophylline could be tailored via selection of the substitution degree and viscosity of HPMC. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A finite element investigation of upper cervical instrumentation.

    PubMed

    Puttlitz, C M; Goel, V K; Traynelis, V C; Clark, C R

    2001-11-15

    The finite element technique was used to predict changes in biomechanics that accompany the application of a novel instrumentation system designed for use in the upper cervical spine. To determine alterations in joint loading, kinematics, and instrumentation stresses in the craniovertebral junction after application of a novel instrumentation system. Specifically, this design was used to assess the changes in these parameters brought about by two different cervical anchor types: C2 pedicle versus C2-C1 transarticular screws, and unilateral versus bilateral instrumentation. Arthrodesis procedures can be difficult to obtain in the highly mobile craniovertebral junction. Solid fusion is most likely achieved when motion is eliminated. Biomechanical studies have shown that C1-C2 transarticular screws provide good stability in craniovertebral constructs; however, implantation of these screws is accompanied by risk of vertebral artery injury. A novel instrumentation system that can be used with transarticular screws or with C2 pedicle screws has been developed. This design also allows for unilateral or bilateral implantation. However, the authors are unaware of any reports to date on the changes in joint loading or instrumentation stresses that are associated with the choice of C2 anchor or unilateral/bilateral use. A ligamentous, nonlinear, sliding contact, three-dimensional finite element model of the C0-C1-C2 complex and a novel instrumentation system was developed. Validation of the model has been previously reported. Finite element models representing combinations of cervical anchor type (C1-C2 transarticular screws vs. C2 pedicle screws) and unilateral versus bilateral instrumentation were evaluated. All models were subjected to compression with pure moments in either flexion, extension, or lateral bending. Kinematic reductions with respect to the intact (uninjured and without instrumentation) case caused by instrumentation use were reported. Changes in loading profiles through the right and left C0-C1 and C1-C2 facets, transverse ligament-dens, and dens-anterior ring of C1 articulations were calculated by the finite element model. Maximum von Mises stresses within the instrumentation were predicted for each model variant and loading scenario. Bilateral instrumentation provided greater motion reductions than the unilateral instrumentation. When used bilaterally, C2 pedicle screws approximate the kinematic reductions and instrumentation stresses (except in lateral bending) that are seen with C1-C2 transarticular screws. The finite element model predicted that the maximum stress was always in the region in which the plate transformed into the rod. To the best of the authors' knowledge, this is the first report of predicting changes in loading in the upper cervical spine caused by instrumentation. The most significant conclusion that can be drawn from the finite element model predictions is that C2 pedicle screw fixation provides the same relative stability and instrumentation stresses as C1-C2 transarticular screw use. C2 pedicle screws can be a good alternative to C2-C1 transarticular screws when bilateral instrumentation is applied.

  7. Instantaneous death due to transorbital reverse penetration of a screw in an accidental fall: unusual autopsy case report and review of the literature.

    PubMed

    Gioia, Sara; Bacci, Mauro; Lancia, Massimo; Carlini, Luigi; Suadoni, Fabio

    2014-03-01

    We present a peculiar autopsy case of a transorbital penetrating head injury, in a male worker, after an accidental fall onto a screw not completely stuck into a wooden board. A 13-cm screw entered the cranium 9.5 cm deep, penetrating with the flat end, a condition defined in literature as "reverse penetration." The death was instantaneous and caused by a neurogenic shock due to injuries to the brain stem and the right cerebellar hemisphere. These injuries, enabled by the length of the screw, are generally described in literature as due to nontransorbital penetrations, frequently associated with posterior entry and a large intracranial injury. The ocular globe has been, furthermore, perfectly preserved thanks to its mobility in the orbit. Even the dynamic of the incident is peculiar because of the stationary nature of the penetrating object, which the victim actively fell on by accident. To the best of our knowledge, the matter is therefore a very peculiar mortal case of transorbital intracranial penetration, whose verified injuries and dynamics are absolutely atypical. The case is now under discussion, and a review of pertinent literature is performed.

  8. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening.

    PubMed

    Dincer Kose, Onur; Karataslı, Burcin; Demircan, Sabit; Kose, Taha Emre; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload.

  9. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening

    PubMed Central

    Demircan, Sabit; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. PMID:28473988

  10. Measuring Scaling Effects in Small Two-Stroke Internal Combustion Engines

    DTIC Science & Technology

    2014-06-20

    Figure 17. The engines ingest air /fuel mixture through a dual mixing screw carburetor to the crankcase. Crankcase compression drives the scavenging...Alex K. Rowton, Captain, USAF AFIT-ENY-T-14-J-36 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright...Patterson Air Force Base, Ohio DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED. The views expressed

  11. The core structure and recombination energy of a copper screw dislocation: a Peierls study

    NASA Astrophysics Data System (ADS)

    Szajewski, B. A.; Hunter, A.; Beyerlein, I. J.

    2017-09-01

    The recombination process of dislocations is central to cross-slip, and transmission through ?3 grain boundaries among other fundamental plastic deformation processes. Despite its importance, a detailed mechanistic understanding remains lacking. We apply a continuous dislocation model, inspired by Peierls and Nabarro, complete with an ab-initio computed ?-surface and continuous units of infinitesimal dislocation slip, towards computing the stress-dependent recombination path of both an isotropic and anisotropic Cu screw dislocation. Under no applied stress, our model reproduces the stacking fault width between Shockley partial dislocations as predicted by discrete linear elasticity. Upon application of a compressive Escaig stress, the two partial dislocations coalesce to a separation of ??. Upon increased loading the edge components of each partial dislocation recede, leaving behind a spread Peierls screw dislocation, indicating the recombined state. We demonstrate that the critical stress required to achieve the recombined state is independent of the shear modulus. Rather the critical recombination stress depends on an energy difference between an unstable fault energy (?) and the intrinsic stacking fault energy (?-?). We report recombination energies of ?W = 0.168 eV/Å and ?W = 0.084 eV/Å, respectively, for the Cu screw dislocation within isotropic and anisotropic media. We develop an analytic model which provides insight into our simulation results which compare favourably with other (similar) models.

  12. Fastener load tests and retention systems tests for cryogenic wind-tunnel models

    NASA Technical Reports Server (NTRS)

    Wallace, J. W.

    1984-01-01

    A-286 stainless steel screws were tested to determine the tensile load capability and failure mode of various screw sizes and types at both cryogenic and room temperature. Additionally, five fastener retention systems were tested by using A-286 screws with specimens made from the primary metallic alloys that are currently used for cryogenic models. The locking system effectiveness was examined by simple no-load cycling to cryogenic temperatures (-275 F) as well as by dynamic and static loading at cryogenic temperatures. In general, most systems were found to be effective retention devices. There are some differences between the various devices with respect to ease of application, cleanup, and reuse. Results of tests at -275 F imply that the cold temperatures act to improve screw retention. The improved retention is probably the result of differential thermal contraction and/or increased friction (thread-binding effects). The data provided are useful in selecting screw sizes, types, and locking devices for model systems to be tested in cryogenic wind tunnels.

  13. Biomechanical stability according to different configurations of screws and rods.

    PubMed

    Ha, Kee-Yong; Hwang, Sung-Chul; Whang, Tae-Hyuk

    2013-05-01

    Comparison of biomechanical strength according to 2 different configurations of screws and rods. To compare the biomechanical strength of different configurations of screws and rods composed of the same material and of the same size. Many complications related to instrumentation have been reported. The incidence of metallic failure would differ according to the materials and configurations of the assembly of the screws and rods used. However, to our knowledge, the biomechanical effects of implant assembly rods and screws with different configurations and different contours have not been reported. Biomechanical testing was conducted to compare top tightening (TT) screw-rod configuration with side tightening (ST) screw-rod configuration. All tests were conducted using a hydraulic all-purpose testing machine. All data were acquired at a rate of 10 Hz. Both screw systems used spinal rods of 6 mm diameter and were made of TiAl4V ELI material. Among 5 types of tests, 3 were conducted on the basis of American Society for Testing and Materials (ASTM) F 1798 to 97 and F1717-10. The other 2 tests were conducted for comparing the characteristics between TT and ST pedicle screws according to modified methods from ASTM F 1717-10 and ASTM F 1798-97. All results including axial gripping capacity and yield forces were obtained using the same methods on the basis of the mentioned ASTM standards. In the axial gripping capacity test, the mean axial gripping capacity of the TT screw-rod configuration was 3332 ± 118 N and that of ST was 2222 ± 147 N in straight rods (P = 0.019). In 15-degree contoured rods, TT was 2988 ± 199 N and ST was 2116 ± 423 N (P = 0.014). In 30-degree contoured rods, TT was 2227 ± 408 N and ST was 1814 ± 285 N (P = 0.009). In the pulling-out test, the pulling-out force of ST was 8695 ± 1616 N and that of TT was 6106 ± 195 N (P = 0.014). In the rod-pushing test, the failure force of ST was 4131 ± 205 N and that of TT was 5639 ± 105 N. In the compressive fatigue test, the maximum load was 145 N in ST and 119 N in TT. In the cycle fatigue test, the fatigue strength of ST was higher than that of TT. In the rod-pushing test, the failure force of ST was 4131 ± 205 N and that of TT was 5639 ± 105 N (P=0.046). Two different configurations of rod-screw systems found statistically significant differences with axial gripping, pulling out, and fatigue failures. ST constructs improved fixation stability over TT constructs. It was concluded that ST configuration may reduce complications related to implantation.

  14. Transarticular facet screw stabilization and dorsal laminectomy in 26 dogs with degenerative lumbosacral stenosis with instability.

    PubMed

    Hankin, Elyshia J; Jerram, Richard M; Walker, Alexander M; King, Michael D; Warman, Christopher G A

    2012-07-01

    To describe outcome after transarticular facet screw stabilization and dorsal laminectomy for treatment of dynamic degenerative lumbosacral stenosis (DLS) in 26 dogs. Retrospective case series. Dogs (n = 26) with dynamic DLS. Medical records (2004-2009) of dogs treated with transarticular facet screw stabilization and dorsal laminectomy were reviewed. Dogs (n = 26) were available for immediate postoperative follow-up, 21 dogs at 6 weeks, and 15 at greater than 6 months. Dogs were evaluated by radiographic assessment and owner questionnaire. Lumbosacral (LS) intervertebral disc (IVD) spaces were measured on pre and postoperative 6-week and 6-month radiographs. In 23 dogs, improvement in clinical signs occurred within 7 days of surgery. Overall postsurgical complication rate directly related to the surgical procedure was 15.4%. LS IVD space measurements taken immediately postoperatively, at 6 weeks, and ≥ 6 months were all significantly increased compared with preoperative measurements. All working dogs (4) returned to full work within 14 months. Most owners (85%) reported their dog was ambulating normally at 6 months with no perceptible lameness during normal activity. All owners perceived their dog's ability to walk, run, and jump after surgery to be improved. Transarticular facet screw stabilization and dorsal laminectomy maintains distraction of the LS IVD space for medium-to-large breed dogs with dynamic DLS with a high degree of owner satisfaction, and is comparable to other reported surgical techniques for DLS. © Copyright 2012 by The American College of Veterinary Surgeons.

  15. A tendril perversion in a helical oligomer: trapping and characterizing a mobile screw-sense reversal† †Electronic supplementary information (ESI) available. CCDC X-ray crystal data for 1a and 1b have been deposited with the CCDC, deposition numbers 1518806 and 1518807. For ESI and crystallographic data in CIF or other electronic format see DOI: 10.1039/c6sc05474a Click here for additional data file. Click here for additional data file.

    PubMed Central

    Tomsett, Michael; Maffucci, Irene; Le Bailly, Bryden A. F.; Byrne, Liam; Bijvoets, Stefan M.; Lizio, M. Giovanna; Raftery, James; Butts, Craig P.; Webb, Simon J.; Contini, Alessandro

    2017-01-01

    Helical oligomers of achiral monomers adopt domains of uniform screw sense, which are occasionally interrupted by screw-sense reversals. These rare, elusive, and fast-moving features have eluded detailed characterization. We now describe the structure and habits of a screw-sense reversal trapped within a fragment of a helical oligoamide foldamer of the achiral quaternary amino acid 2-aminoisobutyric acid (Aib). The reversal was enforced by compelling the amide oligomer to adopt a right-handed screw sense at one end and a left-handed screw sense at the other. The trapped reversal was characterized by X-ray crystallography, and its dynamic properties were monitored by NMR and circular dichroism, and modelled computationally. Raman spectroscopy indicated that a predominantly helical architecture was maintained despite the reversal. NMR and computational results indicated a stepwise shift from one screw sense to another on moving along the helical chain, indicating that in solution the reversal is not localised at a specific location, but is free to migrate across a number of residues. Analogous unconstrained screw-sense reversals that are free to move within a helical structure are likely to provide the mechanism by which comparable helical polymers and foldamers undergo screw-sense inversion. PMID:28451368

  16. Design of Nano Screw Pump for Water Transport and its Mechanisms

    PubMed Central

    Wang, LiYa; Wu, HengAn; Wang, FengChao

    2017-01-01

    Nanopumps conducting fluids through nanochannels have attracted considerable interest for their potential applications in nanofiltration, water desalination and drug delivery. Here, we demonstrate by molecular dynamics (MD) simulations that a nano screw pump is designed with helical nanowires embedded in a nanochannel, which can be used to drive unidirectional water flow. Such helical nanowires have been successfully synthesized in many experiments. By investigating the water transport mechanism through nano screw pumps with different configuration parameters, three transport modes were observed: cluster-by-cluster, pseudo-continuous, and linear-continuous, in which the water flux increases linearly with the rotating speed. The influences of the nanowires’ surface energy and the screw’s diameter on water transport were also investigated. Results showed that the water flux rate increases as the decreasing wettability of helical nanowires. The deviation in water flux in screw pumps with smaller radius is attributed to the weak hydrogen bonding due to space confinement and the hydrophobic blade. Moreover, we also proposed that such screw pumps with appropriate diameter and screw pitch can be used for water desalination. The study provides an insight into the design of multifunctional nanodevices for not only water transport but water desalination in practical applications. PMID:28155898

  17. Recycle of mixed automotive plastics: A model study

    NASA Astrophysics Data System (ADS)

    Woramongconchai, Somsak

    This research investigated blends of virgin automotive plastics which were identified through market analysis. The intent was that this study could be used as a basis for further research in blends of automotive plastics recyclate. The effects of temperature, shear, time, and degree of mixing in a two-roll mill, a single-screw extruder, and a twin-screw extruder were investigated. Properties were evaluated in terms of melt flow, rigidity, strength, impact, heat resistance, electrical resistivity, color, and resistance to water and gasoline. Torque rheometry, dynamic mechanical analysis (DMA), optical and scanning electron microscopy were used to characterize the processability and morphology of major components of the blends. The two-roll mill was operated at high temperature, short time, and low roll speed to avoid discolored and degraded materials. The single-screw extruder and twin-screw extruder were operated at medium and high temperature and high screw speed, respectively, for optimizing head pressure, residence time, shear and degree of mixing of the materials. Melt index increased with extrusion temperature. Flexural modulus increased with the processing temperatures in milling or twin-screw extrusion, but decreased with the increasing single-screw extrusion temperature. Tensile modulus was also enhanced by increasing processing temperature. The tensile strengths for each process were similar and relatively low. The impact strength increased with temperature and roll speed in two-roll milling, was unaffected by the single-screw extrusion temperature and decreased with increasing twin-screw extrusion temperature. Heat resistance was always reduced by higher processing temperature. The volume resistivity increased, water absorption was unaffected and gasoline absorption altered by increased processing temperature. The latter increased somewhat with mill temperature, roll speed (two-roll mill) and higher extrusion temperature (single-screw extruder), but decreased with increased twin-screw extrusion temperature. The flexural modulus of the recycled mixed automotive plastics expected in 2003 was higher than the 1980s and 1990 recycle. Flexural strength effects were not large enough for serious consideration, but were more dominant when compared to those in the 1980s and 1990s. Impact strengths at 20-30 J/m were the lowest value compared to the 1980s and 1990s mixed automotive recycle. Torque rheometry, dynamic mechanical analysis and optical and electron microscopy agreed with each other on the characterization of the processability and morphology of the blends. LLDPE and HDPE were miscible while PP was partially miscible with polyethylene. ABS and nylon-6 were immiscible with the polyolefins, but partially miscible with each other. As expected, the polyurethane foam was immiscible with the other components. The minor components of the model recycle of mixed automotive materials were probably partially miscible with ABS/nylon-6, but there were multiple and unresolved phases in the major blends.

  18. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.

    PubMed

    Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A

    2010-03-01

    Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.

  19. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.

    PubMed

    Hoffmann, Martin F; Burgers, Travis A; Mason, James J; Williams, Bart O; Sietsema, Debra L; Jones, Clifford B

    2014-07-01

    In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1-4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct. Fifteen medium adult synthetic femurs were implanted with a hip prosthesis and were osteotomized in an oblique plane at the level of the implant tip to simulate a Vancouver type B1 periprosthetic fracture. Fractures were fixed with a non-contact bridging periprosthetic proximal femur plate (Zimmer Inc., Warsaw, IN). Three proximal fixation methods were used: Group 1, bicortical screws; Group 2, unicortical screws and one cerclage cable; and Group 3, three cerclage cables. Distally, all groups had bicortical screws. Biomechanical testing was performed using an axial-torsional testing machine in three different loading modalities (axial compression, lateral bending, and torsional/sagittal bending), next in axial cyclic loading to 10,000 cycles, again in the three loading modalities, and finally to failure in torsional/sagittal bending. Group 1 had significantly greater load to failure and was significantly stiffer in torsional/sagittal bending than Groups 2 and 3. After cyclic loading, Group 2 had significantly greater axial stiffness than Groups 1 and 3. There was no difference between the three groups in lateral bending stiffness. The average energy absorbed during cyclic loading was significantly lower in Group 2 than in Groups 1 and 3. Bicortical screw placement achieved the highest load to failure and the highest torsional/sagittal bending stiffness. Additional unicortical screws improved axial stiffness when using cable fixation. Lateral bending was not influenced by differences in proximal fixation. To treat periprosthetic fractures, bicortical screw placement should be attempted to maximize load to failure and torsional/sagittal bending stiffness. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis.

    PubMed

    Wu, Tingting; Fan, Hongyi; Ma, Ruiyang; Chen, Hongyu; Li, Zhi; Yu, Haiyang

    2017-06-01

    Biomechanical factors play a key role in the success of dental implants. Fracture and loosening of abutment screws are major issues. This study investigated the effect of lubricants on the stability of dental implant-abutment connection. As lubricants, graphite and vaseline were coated on the abutment screw surface, respectively, and a blank without lubricant served as the control. The total friction coefficient (μ tot ), clamping force, fatigue behavior and detorque of the joint combined with dynamic cyclic loading were measured under different lubricating conditions. Further, a three-dimensional finite element analysis was used to investigate stress distribution, in conjunction with experimental images. The results showed that the lubricant reduced μ tot , which in turn led to an increase in clamping force. Decrease in loading increased the fatigue life of the screw. However, use of lubricant at high load reduced the fatigue life. Ductile fracture at the first thread of the screw was the chief failure mode, which was due to maximum von Mises stress. Higher stress levels occurred in the lubricant groups. Lubricated screws resulted in lower detorque which made the joint easier to loosen. In conclusion, the lubricant cannot effectively improve the reliability of dental implant-abutment connection. Keeping the interfaces of implant-screw uncontaminated and strengthening the surface of the screw may be recommend for clinical operation and future design. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  2. Individual headless compression screws fixed with three-dimensional image processing technology improves fusion rates of isolated talonavicular arthrodesis.

    PubMed

    Xie, Mei-Ming; Xia, Kang; Zhang, Hong-Xin; Cao, Hong-Hui; Yang, Zhi-Jin; Cui, Hai-Feng; Gao, Shang; Tang, Kang-Lai

    2017-01-23

    Screw fixation is a typical technique for isolated talonavicular arthrodesis (TNA), however, no consensus has been reached on how to select most suitable inserted position and direction. The study aimed to present a new fixation technique and to evaluate the clinical outcome of individual headless compression screws (HCSs) applied with three-dimensional (3D) image processing technology to isolated TNA. From 2007 to 2014, 69 patients underwent isolated TNA by using double Acutrak HCSs. The preoperative three-dimensional (3D) insertion model of double HCSs was applied by Mimics, Catia, and SolidWorks reconstruction software. One HCS oriented antegradely from the edge of dorsal navicular tail where intersected interspace between the first and the second cuneiform into the talus body along the talus axis, and the other one paralleled the first screw oriented from the dorsal-medial navicular where intersected at the medial plane of the first cuneiform. The anteroposterior and lateral X-ray examinations certified that the double HCSs were placed along the longitudinal axis of the talus. Postoperative assessment included the American Orthopaedic Foot & Ankle Society hindfoot (AOFAS), the visual analogue scale (VAS) score, satisfaction score, imaging assessments, and complications. At the mean 44-months follow-up, all patients exhibited good articular congruity and solid bone fusion at an average of 11.26 ± 0.85 weeks (range, 10 ~ 13 weeks) without screw loosening, shifting, or breakage. The overall fusion rates were 100%. The average AOFAS score increased from 46.62 ± 4.6 (range, 37 ~ 56) preoperatively to 74.77 ± 5.4 (range, 64-88) at the final follow-up (95% CI: -30.86 ~ -27.34; p < 0.001). The mean VAS score decreased from 7.01 ± 1.2 (range, 4 ~ 9) to 1.93 ± 1.3 (range, 0 ~ 4) (95% CI: 4.69 ~ 5.48; p < 0.001). One cases (1.45%) and three cases (4.35%) experienced wound infection and adjacent arthritis respectively. The postoperative satisfaction score including pain relief, activities of daily living, and return to recreational activities were good to excellent in 62 (89.9%) cases. Individual 3D reconstruction of HCSs insertion model can be designed with three-dimensional image processing technology in TNA. The technology is safe, effective, and reliable to isolated TNA method with high bone fusion rates, low incidences of complications.

  3. Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique

    PubMed Central

    Kato, Fumihiko; Ito, Keigo; Nakashima, Hiroaki; Machino, Masaaki

    2009-01-01

    Anterior procedures in the cervical spine are feasible in cases having anterior aetiologies such as anterior neural compression and/or severe kyphosis. Halo vests or anterior plates are used concurrently for cases with long segmental fixation. Halo vests are bothersome and anterior plate fixation is not adequately durable. We developed a new anterior pedicle screw (APS) and plate fixation procedure that can be used with fluoroscope-assisted pedicle axis view imaging. Six patients (3 men and 3 women; mean age, 54 years) with anterior multisegmental aetiology were included in this study. Their original diagnoses comprised cervical myelopathy and/or radiculopathy (n = 4), posterior longitudinal ligament ossification (n = 1) and post-traumatic kyphosis (n = 1). All patients underwent anterior decompression and strut grafting with APS and plate fixation. Mean operative time was 192 min and average blood loss was 73 ml. Patients were permitted to ambulate the next day with a cervical collar. Local sagittal alignment was characterised by 3.5° of kyphosis preoperatively, which improved to 6.8° of lordosis postoperatively and 5.2° of lordosis at final follow-up. Postoperative improvement and early bony union were observed in all cases. There was no serious complication except for two cases of dysphagia. Postoperative imaging demonstrated screw exposure in one screw, but no pedicle perforation. APS and plate fixation is useful in selected cases of multisegmental anterior reconstruction of cervical spine. However, the adequate familiarity and experience with both cervical pedicle screw fixation and the imaging technique used for visualising the pedicle during surgery are crucial for this procedure. PMID:19343377

  4. Comparison of Femoral Head Rotation and Varus Collapse Between a Single Lag Screw and Integrated Dual Screw Intertrochanteric Hip Fracture Fixation Device Using a Cadaveric Hemi-Pelvis Biomechanical Model.

    PubMed

    Santoni, Brandon G; Nayak, Aniruddh N; Cooper, Seth A; Smithson, Ian R; Cox, Jacob L; Marberry, Scott T; Sanders, Roy W

    2016-04-01

    This study compared the stabilizing effect of 2 intertrochanteric (IT) fracture fixation devices in a cadaveric hemi-pelvis biomechanical model. Eleven pairs of cadaveric osteopenic female hemi-pelves with intact hip joint and capsular ligaments were used. An unstable IT fracture (OTA 31-A2) was created in each specimen and stabilized with a single lag screw device (Gamma 3) or an integrated dual screw (IDS) device (InterTAN). The hemi-pelves were inverted, coupled to a biaxial apparatus and subjected to 13.5 k cycles of loading (3 months) using controlled, oscillating pelvic rotation (0-90 degrees) plus cyclic axial femoral loading at a 2:1 body weight (BW) ratio. Femoral head rotation and varus collapse were monitored optoelectonically. For specimens surviving 3 months of loading, additional loading was performed in 0.25 × BW/250 cycle increments to a maximum of 4 × BW or failure. Femoral head rotation with IDS fixation was significantly less than the single lag screw construct after 3 months of simulated loading (P = 0.016). Maximum femoral head rotation at the end of 4 × BW loading was 7× less for the IDS construct (P = 0.006). Varus collapse was significantly less with the IDS construct over the entire loading cycle (P = 0.021). In this worst-case model of an osteopenic, unstable, IT fracture, the IDS construct, likely owing to its larger surface area, noncylindrical profile, and fracture compression, provided significantly greater stability and resistance to femoral head rotation and varus collapse.

  5. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    PubMed

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging distal femoral fractures with metaphyseal comminution.

  6. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.

  7. TEGA Whirligig Model

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This is a photo of an engineering model of the Thermal and Evolved-Gas Analyzer (TEGA) instrument on board NASA's Phoenix Mars Lander. This view shows a TEGA oven-loading mechanism beneath the input screen. The screen on the 1-and-1/2-inch-wide funnel has been removed in this model to show the whirligig that is suspended from the screw on the shaft. The black hole underneath is the porthole that leads to the oven.

    A tiny electric current compresses and releases a spring on the shaft. As the shaft spins, the screw bumps the screen, breaking up clumps of material into fine particles so they pass through the one millimeter-square screen openings. The energy applied to the tapping screen is about 0.02 inch per pound, or the force needed to move a one-pound mass two-hundredths of an inch.

    The screw also lifts the three-bladed whirligig so that it jostles fine particles and keeps the oven port open to aid the loading process.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  8. Load positioning system with gravity compensation

    NASA Technical Reports Server (NTRS)

    Hollow, R. H.

    1984-01-01

    A load positioning system with gravity compensation has a servomotor, position sensing feedback potentiometer and velocity sensing tachometer in a conventional closed loop servo arrangement to cause a lead screw and a ball nut to vertically position a load. Gravity compensating components comprise the DC motor, gears, which couple torque from the motor to the lead screw, and constant current power supply. The constant weight of the load applied to the lead screw via the ball nut tend to cause the lead screw to rotate, the constant torque of which is opposed by the constant torque produced by the motor when fed from the constant current source. The constant current is preset as required by the potentiometer to effect equilibration of the load which thereby enables the positioning servomotor to see the load as weightless under both static and dynamic conditions. Positioning acceleration and velocity performance are therefore symmetrical.

  9. A novel modeling approach to the mixing process in twin-screw extruders

    NASA Astrophysics Data System (ADS)

    Kennedy, Amedu Osaighe; Penlington, Roger; Busawon, Krishna; Morgan, Andy

    2014-05-01

    In this paper, a theoretical model for the mixing process in a self-wiping co-rotating twin screw extruder by combination of statistical techniques and mechanistic modelling has been proposed. The approach was to examine the mixing process in the local zones via residence time distribution and the flow dynamics, from which predictive models of the mean residence time and mean time delay were determined. Increase in feed rate at constant screw speed was found to narrow the shape of the residence time distribution curve, reduction in the mean residence time and time delay and increase in the degree of fill. Increase in screw speed at constant feed rate was found to narrow the shape of the residence time distribution curve, decrease in the degree of fill in the extruder and thus an increase in the time delay. Experimental investigation was also done to validate the modeling approach.

  10. The core structure and recombination energy of a copper screw dislocation: a Peierls study

    DOE PAGES

    Szajewski, B. A.; Hunter, A.; Beyerlein, I. J.

    2017-05-19

    The recombination process of dislocations is central to cross-slip, and transmission through Σ3 grain boundaries among other fundamental plastic deformation processes. Despite its importance, a detailed mechanistic understanding remains lacking. In this paper, we apply a continuous dislocation model, inspired by Peierls and Nabarro, complete with an ab-initio computed -surface and continuous units of infinitesimal dislocation slip, towards computing the stress-dependent recombination path of both an isotropic and anisotropic Cu screw dislocation. Under no applied stress, our model reproduces the stacking fault width between Shockley partial dislocations as predicted by discrete linear elasticity. Upon application of a compressive Escaig stress,more » the two partial dislocations coalesce to a separation of ~|b|. Upon increased loading the edge components of each partial dislocation recede, leaving behind a spread Peierls screw dislocation, indicating the recombined state. We demonstrate that the critical stress required to achieve the recombined state is independent of the shear modulus. Rather the critical recombination stress depends on an energy difference between an unstable fault energy (γτ) and the intrinsic stacking fault energy (γτ-γisf). We report recombination energies of ΔW = 0.168 eV/Å and ΔW = 0.084 eV/Å, respectively, for the Cu screw dislocation within isotropic and anisotropic media. Finally, we develop an analytic model which provides insight into our simulation results which compare favourably with other (similar) models.« less

  11. The core structure and recombination energy of a copper screw dislocation: a Peierls study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szajewski, B. A.; Hunter, A.; Beyerlein, I. J.

    The recombination process of dislocations is central to cross-slip, and transmission through Σ3 grain boundaries among other fundamental plastic deformation processes. Despite its importance, a detailed mechanistic understanding remains lacking. In this paper, we apply a continuous dislocation model, inspired by Peierls and Nabarro, complete with an ab-initio computed -surface and continuous units of infinitesimal dislocation slip, towards computing the stress-dependent recombination path of both an isotropic and anisotropic Cu screw dislocation. Under no applied stress, our model reproduces the stacking fault width between Shockley partial dislocations as predicted by discrete linear elasticity. Upon application of a compressive Escaig stress,more » the two partial dislocations coalesce to a separation of ~|b|. Upon increased loading the edge components of each partial dislocation recede, leaving behind a spread Peierls screw dislocation, indicating the recombined state. We demonstrate that the critical stress required to achieve the recombined state is independent of the shear modulus. Rather the critical recombination stress depends on an energy difference between an unstable fault energy (γτ) and the intrinsic stacking fault energy (γτ-γisf). We report recombination energies of ΔW = 0.168 eV/Å and ΔW = 0.084 eV/Å, respectively, for the Cu screw dislocation within isotropic and anisotropic media. Finally, we develop an analytic model which provides insight into our simulation results which compare favourably with other (similar) models.« less

  12. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    PubMed

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Arthroscopic-assisted Locking Compression Plate clavicular hook fixation for unstable fractures of the lateral end of the clavicle: a prospective study

    PubMed Central

    Lee, Kwang Won; Kim, Kap Jung; Kim, Yong In; Kwon, Won Cho; Choy, Won Sik

    2009-01-01

    The aim of this prospective study was to assess the clinical outcomes of an unstable fracture of the lateral end of the clavicle treated with an arthroscopic-assisted locking compressive plate (LCP) clavicular hook plate. Twenty-three patients underwent arthroscopic assisted LCP clavicular hook plate fixation for these fractures. All patients achieved clinical and radiological union over a mean of 4.2 months (range, 3.4–5 months). Four patients (17%) showed some degree of acromial osteolysis. Three patients (13%) showed radiological signs of arthrosis of the acromioclavicular joint. In one patient, a second fracture (stress) was observed between the medial two screws of the plate without an additional injury. Five patients (22%) showed subacromial bursitis on dynamic ultrasonography. The mean Constant and Murley score was 91 points (range, 81–98). The average level of pain in the shoulder at rest and on abduction was 1 (range, 0–2) and 2.4 (range, 0–4), respectively. Based on our experience, arthroscopic-assisted LCP hook plate fixation for the treatment of unstable fractures of the lateral end of the clavicle is not without complications. However, it is an acceptable alternative method that is easy to apply with good results. Furthermore, it prevents rotator cuff impingement, allows early mobilisation and maintains the acromioclavicular joint biomechanics. PMID:19998033

  14. European Scientific Notes. Volume 37, Number 4,

    DTIC Science & Technology

    1983-04-30

    information through the system. Conventional screening of cytologi - V P.ftnost., P... l,,, S."". cal material is done manually using --... _ smears or other...simple single commands in the high level remotely located, cable drive units and Microvision language. Components are a vertical axis ball -screw...specially built compressed air , Jr. cannon . The cannon has a bore of 150 mm (fitted with sleeves for smaller mis- siles), and impact velocities up to

  15. Surf-zone Underwater Robotic Demonstration Platform

    DTIC Science & Technology

    2014-01-01

    dynamically advantageous shape for a robotic system. To address locomotive factors ARA completed a research and technical study based on an Archimedes ...effective hull shape. To study mobility and traction a propulsion system based on an Archimedes screw drive was used. A drive design based on an... Archimedes screw was chosen because of its ability to operate in various mediums with varying flow rates. A test bed was designed and assembled in order to

  16. Failure mode and bending moment of canine pancarpal arthrodesis constructs stabilized with two different implant systems.

    PubMed

    Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K

    2007-12-01

    To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.

  17. Supraintercondylar fractures of the humerus--treatment by the Vigliani osteosynthesis.

    PubMed

    Fama, G

    1987-03-01

    Nineteen cases of supraintercondylar fractures of the humerus treated by the Vigliani osteosynthesis technique are described. This consists of wide transolecranon exposure of the fracture, stabilisation of the epiphyseal fragments with a transcondylar screw, and of the metaphyseo-epiphyseal junction with two condylo-diaphyseal "Eiffel Tower" Kirschner wires. The ulnar nerve is transposed anteriorly and the operation is carried out early in order to prevent neural disturbances and intra and/or periarticular ossification. The results confirm the validity of this method, which respects the delicate structure of this part of the humerus. Postoperative plaster is necessary as an indispensable complement to "minimum" osteosynthesis but this is quite free from risk. The importance of careful and gradual mobilisation of the elbow is also confirmed. Finally, this method combines the advantages of stable osteosynthesis in compression (screw and nut) at the epiphyseal site, with those of elastic osteosynthesis (Kirschner wires) at the metaphyseo-epiphyseal junction.

  18. Pressure Dependence of the Peierls Stress in Aluminum

    NASA Astrophysics Data System (ADS)

    Dang, Khanh; Spearot, Douglas

    2018-03-01

    The effect of pressure applied normal to the {111} slip plane on the Peierls stress in Al is studied via atomistic simulations. Edge, screw, 30°, and 60° straight dislocations are created using the Volterra displacement fields for isotropic elasticity. For each dislocation character angle, the Peierls stress is calculated based on the change in the internal energy, which is an invariant measure of the dislocation driving force. It is found that the Peierls stress for dislocations under zero pressure is in general agreement with previous results. For screw and 60° dislocations, the Peierls stress versus pressure relationship has maximum values associated with stacking fault widths that are multiples of the Peierls period. For the edge dislocation, the Peierls stress decreases with increasing pressure from tension to compression. Compared with the Mendelev potential, the Peierls stress calculated from the Mishin potential is more sensitive to changes in pressure.

  19. Operative treatment of hip fractures in patients receiving hemodialysis.

    PubMed

    Tosun, Bilgehan; Atmaca, Halil; Gok, Umit

    2010-11-01

    Fifteen hips in 13 patients with hip fracture were treated in patients receiving hemodialysis for chronic renal failure. There were four intertrochanteric and 11 femoral neck fractures. 10 of the 11 femoral neck fractures and one of the four intertrochanteric fractures were treated with cemented bipolar hemiarthroplasty. Two intertrochanteric fractures fixed with sliding compression screws. External fixation was used for stabilization in two patients who had femoral neck and intertrochanteric fractures. Two intertrochanteric fractures that were treated with sliding hip screw showed radiological union postoperatively at the 6th month. Of the 11 hemiarthroplasty, four hips developed aseptic loosening (36%). According to Harris hip score grading system, three (37.5%) poor, two (25%) fair, two (25%) good and one (12.5%) case had excellent outcome in the hemiarthroplasty group. The survival of dialysis patients with a hip fracture is markedly reduced. Initial treatment of hemiarthroplasty allows early mobilization and prevents revision surgery.

  20. [Selection of access and positioning for operative treatment of pelvic injuries. Decision-making strategies].

    PubMed

    Ossendorf, C; Hofmann, A; Rommens, P M

    2013-03-01

    Surgical treatment of pelvic ring injuries requires in-depth knowledge of the topographic anatomy of the pelvic bones, joints and soft tissue structures. A wide range of stabilizing techniques is available including bridging plate osteosynthesis, iliosacral compression screw osteosynthesis and transpubic positioning screws. In this article the different treatment strategies with the respective surgical approaches and patient positioning for pelvic ring fractures and combined lesions of the pelvic ring and acetabulum are presented. Pelvic ring lesions with rotational instability are approached from the anterior and occasionally from both the anterior and posterior based on the amount and localization of the instability. In vertically unstable lesions the most unstable part must be addressed first by reduction and fixation of the dislocated part to the axial skeleton. In combined fractures of the pelvis and acetabulum dorsal stabilization is carried out first.

  1. Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study.

    PubMed

    Mansuri, Samir; Abdulkhayum, Abdul Mujeeb; Gazal, Giath; Hussain, Mohammed Abid Zahir

    2013-12-01

    Surgical treatment of fracture mandible using an internal fixation has changed in the last decades to achieve the required rigidity, stability and immediate restoration of function. The aim of the study was to do a Prospective study of 10 patients to determine the efficacy of rectangular grid compression miniplates in mandibular fractures. This study was carried out using 2.0 rectangular grid compression miniplates and 8 mm multidirectional screws as a rigid internal fixation in 10 patients without post operative intermaxillary fixation (IMF). Follow up was done for period of 6 months. All fractures were healed with an absolute stability in post operative period. None of the patient complained of post operative difficulty in occlusion. Within the limits of this study, it can be concluded that rectangular grid compression miniplates was rigid, reliable and thus can be recommended for the treatment of mandibular angle fractures. How to cite this article: Mansuri S, Abdulkhayum AM, Gazal G, Hussain MA. Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study. J Int Oral Health 2013;5(6):93-100 .

  2. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw.

    PubMed

    Cox, Christopher; Earp, Brandon E; Floyd, W Emerson; Blazar, Philip E

    2014-01-01

    To study the results of using a small, headless compression screw (AcuTwist) for thumb interphalangeal (IP) joint and finger distal interphalangeal (DIP) joint arthrodeses. Between November 2007 and January 2012, 48 primary arthrodeses of the thumb IP joint or DIP joint in the other digits were performed in 29 consecutive patients with AcuTwist devices. Indications for arthrodesis included 19 cases of osteoarthritis in 25 fingers, 3 cases of lupus in 9 fingers, 2 cases of post-traumatic osteoarthritis in 2 fingers, and 1 case and finger each of acute trauma, neuromuscular disorder, postinfectious osteoarthritis, boutonniere deformity, and Dupuytren contracture. Charts were reviewed for clinical data, and radiographs were assessed for alignment and healing. Age averaged 59 years and follow-up averaged 12 months (range, 2-50 mo). Union occurred in 43 out of 46 fingers (94%). There were no cases of nail deformity, wound complications, tip hypersensitivity, or clinically notable malalignment. Three arthrodeses failed to fuse, including 2 asymptomatic nonunions and 1 fixation loss requiring revision with autograft. The complication rate was 9%. Distal digital joint arthrodesis with the AcuTwist resulted in a fusion rate of 94% with a complication rate of 9%. Our rate of fusion compares favorably with prior series using other methods of fixation. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. A novel approach to support formulation design on twin screw wet granulation technology: Understanding the impact of overarching excipient properties on drug product quality attributes.

    PubMed

    Willecke, N; Szepes, A; Wunderlich, M; Remon, J P; Vervaet, C; De Beer, T

    2018-04-21

    The overall objective of this work is to understand how excipient characteristics influence the drug product quality attributes and process performance of a continuous twin screw wet granulation process. The knowledge gained in this study is intended to be used for Quality by Design (QbD)-based formulation design and formulation optimization. Three principal components which represent the overarching properties of 8 selected pharmaceutical fillers were used as factors, whereas factors 4 and 5 represented binder type and binder concentration in a design of experiments (DoE). The majority of process parameters were kept constant to minimize their influence on the granule and drug product quality. 27 DoE batches consisting of binary filler/binder mixtures were processed via continuous twin screw wet granulation followed by tablet compression. Multiple linear regression models were built providing understanding of the impact of filler and binder properties on granule and tablet quality attributes (i.e. 16 DoE responses). The impact of fillers on the granule and tablet responses was more dominant compared to the impact of binder type and concentration. The filler properties had a relevant effect on granule characteristics, such as particle size, friability and specific surface area. Binder type and concentration revealed a relevant influence on granule flowability and friability as well as on the compactability (required compression force during tableting to obtain target hardness). In order to evaluate the DoE models' validity, a verification of the DoE models was performed with new formulations (i.e. a new combination of filler, binder type and binder concentration) which were initially not included in the dataset used to build the DoE models. The combined PCA (principle component analysis)/DoE approach allowed to link the excipient properties with the drug product quality attributes. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application.

    PubMed

    Liebsch, Christian; Zimmermann, Julia; Graf, Nicolas; Schilling, Christoph; Wilke, Hans-Joachim; Kienle, Annette

    2018-01-01

    Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0N shear force + 20.0N per step, 51.0N tension force + 10.2N per step, 4.2Nm bending moment + 0.8Nm per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0mg/cc HA, pedicle width 9.8 ± 0.6mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9-2.2mm at 240N shear force) were reproducible within the variation range of the in vitro experiments (0.6-3.5mm at 240N shear force). Screw loosening occurred continuously in each case between 140N and 280N, while abrupt failures of the specimen were observed only in vitro. In the mechanical testing model, no translational motion was detected in the screw entry point, while in vitro, translational motions of up to 2.5mm in inferior direction were found, leading to a slight shift of the centre of rotation towards the screw tip. Translational motions of the screw tip of about 5mm in superior direction were observed both in vitro and in the mechanical testing model, while they were continuous in the mechanical testing model and rapidly increasing after screw loosening initiation in vitro. The overall pedicle screw loosening characteristics were qualitatively and quantitatively similar between the mechanical testing model and the human vertebral specimens as long as there was no translation of the screw at the screw entrance point. Therefore, the novel mechanical testing model represents a promising method for the standardized testing of pedicle screws regarding screw loosening for cases where the screw rotates around a point close to the screw entry point. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.

    PubMed

    Akamaru, Tomoyuki; Kawahara, Norio; Sakamoto, Jiro; Yoshida, Akira; Murakami, Hideki; Hato, Taizo; Awamori, Serina; Oda, Juhachi; Tomita, Katsuro

    2005-12-15

    A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total spondylectomy. The most recent reconstruction techniques following total spondylectomy for malignant spinal tumor include a titanium mesh cage filled with autologous bone as an anterior strut. The need for additional anterior instrumentation with posterior pedicle screws and rods is controversial. Transmission of the mechanical stress to grafted bone inside a titanium mesh cage is important for fusion and remodeling. To our knowledge, there are no published reports comparing the load-sharing properties of the different reconstruction methods following total spondylectomy. A 3-dimensional finite-element model of the reconstructed spine (T10-L4) following total spondylectomy at T12 was constructed. A Harms titanium mesh cage (DePuy Spine, Raynham, MA) was positioned as an anterior replacement, and 3 types of the reconstruction methods were compared: (1) multilevel posterior instrumentation (MPI) (i.e., posterior pedicle screws and rods at T10-L2 without anterior instrumentation); (2) MPI with anterior instrumentation (MPAI) (i.e., MPAI [Kaneda SR; DePuy Spine] at T11-L1); and (3) short posterior and anterior instrumentation (SPAI) (i.e., posterior pedicle screws and rods with anterior instrumentation at T11-L1). The mechanical energy stress distribution exerted inside the titanium mesh cage was evaluated and compared by finite-element analysis for the 3 different reconstruction methods. Simulated forces were applied to give axial compression, flexion, extension, and lateral bending. In flexion mode, the energy stress distribution in MPI was higher than 3.0 x 10 MPa in 73.0% of the total volume inside the titanium mesh cage, while 38.0% in MPAI, and 43.3% in SPAI. In axial compression and extension modes, there were no remarkable differences for each reconstruction method. In left-bending mode, there was little stress energy in the cancellous bone inside the titanium mesh cage in MPAI and SPAI. This experiment shows that from the viewpoint of stress shielding, the reconstruction method, using additional anterior instrumentation with posterior pedicle screws (MPAI and SPAI), stress shields the cancellous bone inside the titanium mesh cage to a higher degree than does the system using posterior pedicle screw fixation alone (MPI). Thus, a reconstruction method with no anterior fixation should be better at allowing stress for remodeling of the bone graft inside the titanium mesh cage.

  6. Joint kinematics of surgeons during lumbar pedicle screw placement.

    PubMed

    Park, Jeong-Yoon; Kim, Kyung-Hyun; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun

    2016-12-01

    A surgical robot for spine surgery has recently been developed. The objective is to assess the joint kinematics of the surgeon during spine surgery. We enrolled 18 spine surgeons, who each performed pedicle screw placement, and used an optoelectronic motion analysis system. Using three-dimensional (3D) motion images, distance changes in five joints and angle changes in six joints were calculated during surgery. Distance fluctuations increased gradually from the proximal to the distal joint. Angle fluctuations were largest at the distal point but did not gradually increase, and the elbow showed the second largest fluctuation. Changes along the X axis were larger than those of the Y and Z axes. The distances gradually increased from proximal portions of the body to the hand. In angle changes, the elbow was most dynamic during pedicle screw placement. The surgeons' whole joints carry out a harmonic role during lumbar pedicle screw placement. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    PubMed

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Comparison of the Lag Screw Placements for the Treatment of Stable and Unstable Intertrochanteric Femoral Fractures regarding Trabecular Bone Failure.

    PubMed

    Celik, Talip; Mutlu, Ibrahim; Ozkan, Arif; Kisioglu, Yasin

    2016-01-01

    Background. In this study, the cut-out risk of Dynamic Hip Screw (DHS) was investigated in nine different positions of the lag screw for two fracture types by using Finite Element Analysis (FEA). Methods. Two types of fractures (31-A1.1 and A2.1 in AO classification) were generated in the femur model obtained from Computerized Tomography images. The DHS model was placed into the fractured femur model in nine different positions. Tip-Apex Distances were measured using SolidWorks. In FEA, the force applied to the femoral head was determined according to the maximum value being observed during walking. Results. The highest volume percentage exceeding the yield strength of trabecular bone was obtained in posterior-inferior region in both fracture types. The best placement region for the lag screw was found in the middle of both fracture types. There are compatible results between Tip-Apex Distances and the cut-out risk except for posterior-superior and superior region of 31-A2.1 fracture type. Conclusion. The position of the lag screw affects the risk of cut-out significantly. Also, Tip-Apex Distance is a good predictor of the cut-out risk. All in all, we can supposedly say that the density distribution of the trabecular bone is a more efficient factor compared to the positions of lag screw in the cut-out risk.

  9. Biomechanical Strength of Retrograde Fixation in Proximal Third Scaphoid Fractures.

    PubMed

    Daly, Charles A; Boden, Allison L; Hutton, William C; Gottschalk, Michael B

    2018-04-01

    Current techniques for fixation of proximal pole scaphoid fractures utilize antegrade fixation via a dorsal approach endangering the delicate vascular supply of the dorsal scaphoid. Volar and dorsal approaches demonstrate equivalent clinical outcomes in scaphoid wrist fractures, but no study has evaluated the biomechanical strength for fractures of the proximal pole. This study compares biomechanical strength of antegrade and retrograde fixation for fractures of the proximal pole of the scaphoid. A simulated proximal pole scaphoid fracture was produced in 22 matched cadaveric scaphoids, which were then assigned randomly to either antegrade or retrograde fixation with a cannulated headless compression screw. Cyclic loading and load to failure testing were performed and screw length, number of cycles, and maximum load sustained were recorded. There were no significant differences in average screw length (25.5 mm vs 25.6 mm, P = .934), average number of cyclic loading cycles (3738 vs 3847, P = .552), average load to failure (348 N vs 371 N, P = .357), and number of catastrophic failures observed between the antegrade and retrograde fixation groups (3 in each). Practical equivalence between the 2 groups was calculated and the 2 groups were demonstrated to be practically equivalent (upper threshold P = .010). For this model of proximal pole scaphoid wrist fractures, antegrade and retrograde screw configuration have been proven to be equivalent in terms of biomechanical strength. With further clinical study, we hope surgeons will be able to make their decision for fixation technique based on approaches to bone grafting, concern for tenuous blood supply, and surgeon preference without fear of poor biomechanical properties.

  10. Design and manufacture a coconut milk squeezer

    NASA Astrophysics Data System (ADS)

    Wayan Surata, I.; Gde Tirta Nindhia, Tjokorda; Budyanto, D.; Yulianto, A. E.

    2017-05-01

    The process of cooking oil production generally is started by grating the ripe coconut meat, then pressing the grated meat to obtain coconut milk, and finally heating the coconut milk to obtain the cooking oil. Pressing mechanism to obtain coconut milk is a very important step and decisive in the process of producing cooking oil. The amount of milk produced depends on the pressure applied at the time of pressing grated coconut. The higher the pressure, the more milk is obtained. Some commercial mechanical pressing tools that available in the market are not efficient due to the working steps too much and take long time per cycle of work. The aims of this study was to design and manufacture a power screw squeezer for the collection of coconut milk. Power screw produces a compressive force in the cylinder to push and press the grated coconut until the end of the cylinder while the coconut milk and coconut dregs flow out simultaneously. Screw press was designed using straight shaft configuration with square profile. Performance test was done to investigate the actual capacity and yield of milk produced. The results showed that squeezer of grated coconut worked well with capacity an average of 13,63 kg/h and coconut milk yield of 58%.

  11. [Atlanto-axial pedicle screw fixation through posterior approach for treatment of atlanto-axial joint instability].

    PubMed

    Zuo, Chun-Guang; Liu, Xia-Jun; Wang, Xin-Hu; Wang, Jian-shun

    2013-01-01

    To discuss the therapeutic effects of the atlantoaxial pedicle screw system fixation in treatment of atlantoaxial instability. From June 2003 to March 2010, 32 patients with atlantoaxial instability were treated by atlantoaxial pedicle screw system fixation, included 21 males and 11 females wiht an average age of 42.5 years old ranging from 28 to 66 years. Among them, 18 cases were odontoid process fractures, 7 were congenital dissociate odontoid process, 4 were Jefferson fracture combined with odontoid fracture, 3 were rheumatic arthritis causing atlantoaxial instability. All patients suffered from the atlantoaxial subluxation and atlantoaxial instability. The JOA score ranged from 4 to 14 (means 9.1 +/- 0.3) before operation. The patients had some image examination including the X-ray of cervical vertebrae (include of dynamic position film), spiral CT 3D reconstruction and/or MRI. The position of pedicle screw system implantation,the angle of pedicle screw system implantation and screw length were measured. Operating skull traction. Operation undewent general anesthesia, implanted the pedicle screw, reduction and bone fusion under direct vision. The bone was fixated between posterior arch of atlas and lamina of axis by the lateral combination bended to posterior. One hundred and twenty-eight atlantoaxial pedicle screws were implanted in 32 patients. No patient had the injure of spinal cord, nerve root and vertebral artery. All patients were followed-up from 6 to 48 months (averaged 16 months). After operation, the JOA score ranged from 11 to 17 (averaged 15.9 +/- 0.2), improvement rate was 86.1%. The fracture of odontoid process were healing completely. All fusion bone were combinated. The internal fixation wasn't loosening and breaking. The atlantoaxial pedicle screw system fixation was effective method to treat atlantoaxial instability. The method had many advantages, such as provide rigid and short segment fixation, safe and simple, high fusion rate. The method was worth in clinical application.

  12. Development of a Novel Continuous Processing Technology for Functionally Graded Composite Energetic Materials Using an Inverse Design Procedure

    DTIC Science & Technology

    2006-01-01

    is naturally suited to produce this type of gradient from one composition to another. Operating a twin screw extruder at one steady condition and...dynamically changing the ingredients to produce a new formulation will result in the extrudate changing from the original composition to second one...Because of the inherent backmixing in a twin screw extruder , an abrupt change in ingredients results in a more gradual change in the composition of

  13. Column-by-column observation of dislocation motion in CdTe: Dynamic scanning transmission electron microscopy

    NASA Astrophysics Data System (ADS)

    Li, Chen; Zhang, Yu-Yang; Pennycook, Timothy J.; Wu, Yelong; Lupini, Andrew R.; Paudel, Naba; Pantelides, Sokrates T.; Yan, Yanfa; Pennycook, Stephen J.

    2016-10-01

    The dynamics of partial dislocations in CdTe have been observed at the atomic scale using aberration-corrected scanning transmission electron microscopy (STEM), allowing the mobility of different dislocations to be directly compared: Cd-core Shockley partial dislocations are more mobile than Te-core partials, and dislocation cores with unpaired columns have higher mobility than those without unpaired columns. The dynamic imaging also provides insight into the process by which the dislocations glide. Dislocations with dangling bonds on unpaired columns are found to be more mobile because the dangling bonds mediate the bond exchanges required for the dislocations to move. Furthermore, a screw dislocation has been resolved to dissociate into a Shockley partial-dislocation pair along two different directions, revealing a way for the screw dislocation to glide in the material. The results show that dynamic STEM imaging has the potential to uncover the details of dislocation motion not easily accessible by other means.

  14. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    PubMed

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and 2578 cycles (range, 2540-2623) in the transsacral group (p = 0.153). The cemented group absorbed more energy before failure (8.2 × 10 5 N*cycles; range, 6.6 × 10 5 -22.6 × 10 5 ) compared with the transsacral group (6.5 × 10 5 N*cycles; range, 6.4 × 10 5 -6.7 × 10 5 ) (p = 0.016). There was no difference with the numbers available in terms of fracture site motion (sacroiliac: 2.9 mm, range, 0.7-5.4; cemented: 1.2 mm, range, 0.6-1.9; transsacral: 2.1 mm, range, 1.2-4.8). Probability values for all between-group comparisons were greater than 0.05. The addition of cement to standard sacroiliac screw fixation seemed to change the mode and dynamics of failure in this cadaveric mechanical model. Although no advantages to cement were observed in terms of screw motion or cycles to failure among the different constructs, a cemented, two-screw sacroiliac screw construct resulted in less screw subsidence and greater energy absorbed to failure than an uncemented single transsacral screw. In osteoporotic bone, the addition of cement to sacroiliac screw fixation might improve screw anchorage. However, larger mechanical studies using these findings as pilot data should be performed before applying these preliminary findings clinically.

  15. Enhancement of biodegradation and osseointegration of poly(ε-caprolactone)/calcium phosphate ceramic composite screws for osteofixation using calcium sulfate.

    PubMed

    Wu, Chang-Chin; Hsu, Li-Ho; Tsai, Yuh-Feng; Sumi, Shoichiro; Yang, Kai-Chiang

    2016-04-04

    Internal fixation devices, which can stabilize and realign fractured bone, are widely used in fracture management. In this paper, a biodegradable composite fixator, composed of poly(ε-caprolactone), calcium phosphate ceramic and calcium sulfate (PCL/CPC/CS), is developed. The composition of CS, which has a high dissolution rate, was expected to create a porous structure to improve osteofixation to the composite fixator. PCL, PCL/CPC, and PCL/CPC/CS samples were prepared and their physical properties were characterized in vitro. In vivo performance of the composite screws was verified in the distal femurs of rabbits. Results showed that the PCL/CPC/CS composite had a higher compressive strength (28.55 ± 3.32 MPa) in comparison with that of PCL (20.64 ± 1.81 MPa) (p < 0.05). A larger amount of apatite was formed on PCL/CPC/CS than on PCL/CPC, while no apatite was found on PCL after simulated body fluid immersion. In addition, PCL/CPC/CS composites also had a faster in vitro degradation rate (13.05 ± 3.42% in weight loss) relative to PCL (1.79 ± 0.23%) and PCL/CPC (4.32 ± 2.18%) (p < 0.001). In animal studies, PCL/CPC/CS screws showed a greater volume loss than that of PCL or PCL/CPC at 24 weeks post-implantation. Under micro-computerized tomography observation, animals with PCL/CPC/CS implants had better osseointegration in terms of the structural parameters of the distal metaphysis, including trabecular number, trabecular spacing, and connectivity density, than the PCL screw. This study reveals that the addition of CS accelerates the biodegradation and enhanced apatite formation of the PCL/CPC composite screw. This osteoconductive PCL/CPC/CS is a good candidate material for internal fixation devices.

  16. Effects of Instantaneous Multiband Dynamic Compression on Speech Intelligibility

    NASA Astrophysics Data System (ADS)

    Herzke, Tobias; Hohmann, Volker

    2005-12-01

    The recruitment phenomenon, that is, the reduced dynamic range between threshold and uncomfortable level, is attributed to the loss of instantaneous dynamic compression on the basilar membrane. Despite this, hearing aids commonly use slow-acting dynamic compression for its compensation, because this was found to be the most successful strategy in terms of speech quality and intelligibility rehabilitation. Former attempts to use fast-acting compression gave ambiguous results, raising the question as to whether auditory-based recruitment compensation by instantaneous compression is in principle applicable in hearing aids. This study thus investigates instantaneous multiband dynamic compression based on an auditory filterbank. Instantaneous envelope compression is performed in each frequency band of a gammatone filterbank, which provides a combination of time and frequency resolution comparable to the normal healthy cochlea. The gain characteristics used for dynamic compression are deduced from categorical loudness scaling. In speech intelligibility tests, the instantaneous dynamic compression scheme was compared against a linear amplification scheme, which used the same filterbank for frequency analysis, but employed constant gain factors that restored the sound level for medium perceived loudness in each frequency band. In subjective comparisons, five of nine subjects preferred the linear amplification scheme and would not accept the instantaneous dynamic compression in hearing aids. Four of nine subjects did not perceive any quality differences. A sentence intelligibility test in noise (Oldenburg sentence test) showed little to no negative effects of the instantaneous dynamic compression, compared to linear amplification. A word intelligibility test in quiet (one-syllable rhyme test) showed that the subjects benefit from the larger amplification at low levels provided by instantaneous dynamic compression. Further analysis showed that the increase in intelligibility resulting from a gain provided by instantaneous compression is as high as from a gain provided by linear amplification. No negative effects of the distortions introduced by the instantaneous compression scheme in terms of speech recognition are observed.

  17. Analysis of Modeling Parameters on Threaded Screws.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vigil, Miquela S.; Brake, Matthew Robert; Vangoethem, Douglas

    2015-06-01

    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry cause issues when generating a mesh of the model. This paper will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. Themore » results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.« less

  18. [Design of Minimal Invasive Screw on Posterior Pelvis Ring and Pelvic Finite Element Analysis].

    PubMed

    Tang, Fan; Min, Li; Wang, Yan-Ling; Qu, Bo; Zhou, Yong; Luo, Yi; Zhang, Wen-Li; Shi, Rui; Duan, Hong; Tu, Chong-Qi

    2017-09-01

    To design minimal invasive screw on posterior pelvic ring and perform threedimensional finite element analysis based on a pelvis finite element model. We measured the pelvic anatomical data of 20 healthy volunteers and identified potential designs for minimal invasive screw on posterior pelvic ring. A finite element model of pelvis was then established. Threedimensional finite element analyses were performed under static and dynamic mechanical loading,respectively. Three screw tracks on ilium (A,B and C) were identified based on a threedimensional reconstruction of pelvis. Nail track B and C had greater length and width,but shorter distance between nailing and soft tissue compared with nail track A. Static loading under an external rotation load of 500 N generated a maximum Mises Von stress of 582.05 Pa and sacral iliac complex of 107.38 Pa. The greatest strain was located at the articular cartilage on the side of the nail,followed by lateral sacral joint cartilage and symphysis pubis. The largest displacement was located at the ilium on the side of the nail,with a gradient decrease to the opposite side. The largest displacement of the anterior superior iliac spine was 0.35 cm on the side of the nail. The dynamic loading identified displacement of the anterior superior iliac spine with 1.5 mm in Z axis,1.8 mm in X axis and -0.2 mm in Y axis; and displacement of the pubic bone with 0.8 mm in Z axis,1.0 mm in X axis and 0.03 mm in Y axis. The maximum displacement appeared along the impact direction: Y axis. Relatively large equivalent stress was found in pubis and ischium,anterior superior iliac spine,sacrum,acetabular that are prone to fracture. With increased impact force,the stress of pelvis increased over time. The maximum impact force,stress and displacement of the pelvis occurred at 10 ms when peak force was reached. Under the impact of 4 000 N and 5 000 N,the bone was subject to a stress level of over 200 MPa,exceeding its average yield strength,which suggests a possibility of pelvic fracture. Taking B/C as a main screw track and A as an auxiliary screw track is a reasonable choice. The pelvic finite element model lays a foundation for further studies into sacral fracture and design of screw tracks.

  19. Shoulder arthrodesis for treatment of flail shoulder in children with polio.

    PubMed

    Miller, Joshua D; Pinero, Joseph R; Goldstein, Rachel; Yen, Yi-Meng; Eves, William; Otsuka, Norman Y

    2011-09-01

    Poliomyelitis in children can cause paralysis of shoulder girdle muscles leading to a flail shoulder. Shoulder arthrodesis is indicated as a possible treatment for these children in order to stabilize the shoulder. This retrospective study reviewed all shoulder arthrodesis surgeries owing to complications of polio performed at a major medical institution between 1981 and 1996 to assess position of fusion, radiographic evidence of fusion, complications, and patient satisfaction. A review of medical records identified 11 patients undergoing 13 shoulder arthrodesis procedures, with a mean age of 14.7 years at the time of the procedure. Internal fixation was achieved with large cancellous screws in 8 patients and a Dynamic Compression Plate (DCP) plate in 5 procedures. Average follow-up period was 41 months. Eight patients were placed into a spica cast and 5 used a sling postoperatively. Shoulder arthrodesis surgery in this cohort resulted in an average position of fusion with 42.3 degrees of abduction, 23.8 degrees of flexion, and 26.2 degrees of internal rotation. Twelve of the 13 procedures assessed for radiographic union demonstrated fusion. The most common complications were malrotation and nonunion. Of the 13 procedures, 2 underwent humeral osteotomies for malrotation, and 1 with 6.5 mm cancellous screws required revision with a DCP plate owing to nonunion. Six patients underwent hardware removal, 3 of which were specifically owing to complaints of painful hardware. At final follow-up, no patient reported pain and all expressed satisfaction with their results and improved shoulder function after repair. This study is the largest series of shoulder arthrodesis surgeries for treatment of patients with a flail shoulder from polio to date, providing a more thorough analysis of its efficacy as an indicated treatment. Level III-Retrospective Comparative Study.

  20. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Drilling the near cortex with elongated figure-of-8 holes to reduce the stiffness of a locking compression plate construct.

    PubMed

    Chen, Jerry Yongqiang; Zhou, Zhihong; Ang, Benjamin Fu Hong; Yew, Andy Khye Soon; Chou, Siaw Meng; Chia, Shi-Lu; Koh, Joyce Suang Bee; Howe, Tet Sen

    2015-12-01

    To compare the stiffness of locking compression plate (LCP) constructs with or without drilling the near cortex with elongated figure-of-8 holes. 24 synthetic bones were sawn to create a 10-mm gap and were fixed with a 9-hole 4.5-mm narrow LCP. In 12 bones, the near cortex of the adjacent holes to the LCP holes was drilled to create elongated figure-of-8 holes before screw insertion. The stiffness of LCP constructs under axial loading or 4-point bending was assessed by (1) dynamic quasi-physiological testing for fatigue strength, (2) quasi-static testing for stiffness, and (3) testing for absolute strength to failure. None of the 24 constructs had subcatastrophic or catastrophic failure after 10 000 cycles of fatigue loading (p=1.000). The axial stiffness reduced by 16% from 613±62 to 517±44 N/mm (p=0.012) in the case group, whereas the bending stiffness was 16±1 Nm2 in both groups (p=1.000). The maximum axial load to catastrophic failure was 1596±84 N for the control group and 1627±48 N for the case group (p=0.486), whereas the maximum bending moment to catastrophic failure was 79±12 and 80±10 Nm, respectively (p=0.919). Drilling the near cortex with elongated figure-of-8 holes reduces the axial stiffness of the LCP construct, without compromising its bending stiffness or strength.

  2. Dislocation Multiplication in the Early Stage of Deformation in Mo Single Crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsiung, L.; Lassila, D.H.

    Initial dislocation structure in annealed high-purity Mo single crystals and deformation substructure in a crystal subjected to 1% compression have been examined and studied using transmission electron microscopy (TEM) techniques in order to investigate dislocation multiplication mechanisms in the early stage of plastic deformation. The initial dislocation density is in a range of 10{sup 6} {approx} 10{sup 7} cm{sup -2}, and the dislocation structure is found to contain many grown-in superjogs along dislocation lines. The dislocation density increases to a range of 10{sup 8} {approx} 10{sup 9} cm{sup -2}, and the average jog height is also found to increase aftermore » compressing for a total strain of 1%. It is proposed that the preexisting jogged screw dislocations can act as (multiple) dislocation multiplication sources when deformed under quasi-static conditions. The jog height can increase by stress-induced jog coalescence, which takes place via the lateral migration (drift) of superjogs driven by unbalanced line-tension partials acting on link segments of unequal lengths. The coalescence of superjogs results in an increase of both link length and jog height. Applied shear stress begins to push each link segment to precede dislocation multiplication when link length and jog height are greater than critical lengths. This ''dynamic'' dislocation multiplication source is suggested to be crucial for the dislocation multiplication in the early stage of plastic deformation in Mo.« less

  3. Cryotherapy with dynamic intermittent compression for analgesia after anterior cruciate ligament reconstruction. Preliminary study.

    PubMed

    Murgier, J; Cassard, X

    2014-05-01

    Cryotherapy is a useful adjunctive analgesic measure in patients with postoperative pain following anterior cruciate ligament (ACL) surgery. Either static permanent compression or dynamic intermittent compression can be added to increase the analgesic effect of cryotherapy. Our objective was to compare the efficacy of these two compression modalities combined with cryotherapy in relieving postoperative pain and restoring range of knee motion after ligament reconstruction surgery. When combined with cryotherapy, a dynamic and intermittent compression is associated with decreased analgesic drug requirements, less postoperative pain, and better range of knee motion compared to static compression. We conducted a case-control study of consecutive patients who underwent anterior cruciate ligament reconstruction at a single institution over a 3-month period. Both groups received the same analgesic drug protocol. One group was managed with cryotherapy and dynamic intermittent compression (Game Ready(®)) and the other with cryotherapy and static compression (IceBand(®)). Of 39 patients, 20 received dynamic and 19 static compression. In the post-anaesthesia recovery unit, the mean visual analogue scale (VAS) pain score was 2.4 (range, 0-6) with dynamic compression and 2.7 (0-7) with static compression (P=0.3); corresponding values were 1.85 (0-9) vs. 3 (0-8) (P=0.16) after 6 hours and 0.6 (0-3) vs. 1.14 (0-3) (P=0.12) at discharge. The cumulative mean tramadol dose per patient was 57.5mg (0-200mg) with dynamic compression and 128.6 mg (0-250 mg) with static compression (P=0.023); corresponding values for morphine were 0mg vs. 1.14 mg (0-8 mg) (P<0.05). Mean range of knee flexion at discharge was 90.5° (80°-100°) with dynamic compression and 84.5° (75°-90°) with static compression (P=0.0015). Dynamic intermittent compression combined with cryotherapy decreases analgesic drug requirements after ACL reconstruction and improves the postoperative recovery of range of knee motion. Level III, case-control study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Comparison of the Lag Screw Placements for the Treatment of Stable and Unstable Intertrochanteric Femoral Fractures regarding Trabecular Bone Failure

    PubMed Central

    Mutlu, Ibrahim; Ozkan, Arif; Kisioglu, Yasin

    2016-01-01

    Background. In this study, the cut-out risk of Dynamic Hip Screw (DHS) was investigated in nine different positions of the lag screw for two fracture types by using Finite Element Analysis (FEA). Methods. Two types of fractures (31-A1.1 and A2.1 in AO classification) were generated in the femur model obtained from Computerized Tomography images. The DHS model was placed into the fractured femur model in nine different positions. Tip-Apex Distances were measured using SolidWorks. In FEA, the force applied to the femoral head was determined according to the maximum value being observed during walking. Results. The highest volume percentage exceeding the yield strength of trabecular bone was obtained in posterior-inferior region in both fracture types. The best placement region for the lag screw was found in the middle of both fracture types. There are compatible results between Tip-Apex Distances and the cut-out risk except for posterior-superior and superior region of 31-A2.1 fracture type. Conclusion. The position of the lag screw affects the risk of cut-out significantly. Also, Tip-Apex Distance is a good predictor of the cut-out risk. All in all, we can supposedly say that the density distribution of the trabecular bone is a more efficient factor compared to the positions of lag screw in the cut-out risk. PMID:27995133

  5. Changes in the functional properties and antinutritional factors of extruded hard-to-cook common beans (Phaseolus vulgaris, L.).

    PubMed

    Batista, Karla A; Prudêncio, Sandra H; Fernandes, Kátia F

    2010-04-01

    The biochemical and functional properties of 2 hard-to-cook common bean cultivars (Phaseolus vulgaris, L.) were investigated after the extrusion process. Beans of BRS pontal and BRS grafite cultivars were milled and extruded at 150 degrees C, with a compression ratio screw of 3 : 1, 5-mm die, and screw speed of 150 rpm. Extrudate flours were evaluated for water solubility (WS), water absorption index (WAI), oil absorption capacity (OAC), foaming capacity (FC), emulsifying activity (EA), antinutritional factors, and in vitro protein and starch digestibility. Results indicated that the extrusion significantly decreased antinutrients such as phytic acid, lectin, alpha-amylase, and trypsin inhibitors, reduced the emulsifying capacity and eliminated the FC in both BRS pontal and BRS grafite cultivars. In addition, the WS, WAI, and in vitro protein and starch digestibility were improved by the extrusion process. These results indicate that it is possible to produce new extruded products with good functional and biochemical properties from these common bean cultivars.

  6. Lumbar vertebral hemangioma mimicking lateral spinal canal stenosis: case report and review of literature.

    PubMed

    Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis

    2014-03-01

    Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended.

  7. Lumbar vertebral hemangioma mimicking lateral spinal canal stenosis: Case report and review of literature

    PubMed Central

    Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis

    2014-01-01

    Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended. PMID:24090267

  8. Management of comminuted proximal ulna fracture-dislocations using a multiplanar locking intramedullary nail.

    PubMed

    Edwards, Scott G; Argintar, Evan; Lamb, Joshua

    2011-06-01

    Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.

  9. Results of Arthroscopic Ankle Arthrodesis with Fixation Using Two Parallel Headless Compression Screws in a Heterogenic Group of Patients

    PubMed Central

    Kolodziej, Lukas; Sadlik, Boguslaw; Sokolowski, Sebastian; Bohatyrewicz, Andrzej

    2017-01-01

    Background: As orthopedic surgeons become skilled in ankle arthroscopy technique and evidence -based data is supporting its use, arthroscopic ankle arthrodesis (AAA) will likely continue to increase, but stabilization methods have not been described clearly. We present a technique for two parallel 7.3-mm headless compression screws fixation (HCSs) for AAA in cases of ankle arthritis with different etiology, both traumatic and non-traumatic, including neuromuscular and inflammatory patients. Materials and Methods: We retrospectively verified 24 consecutive patients (25 ankles) who underwent AAA between 2011 and 2015. The average follow-up was 26 months (range 18 to 52 months). Arthrodesis was performed in 16 patients due to posttraumatic arthritis (in 5 as a sequela of pilon, 6 ankles, 3 tibia fractures, and 2 had arthritis due to chronic instability after lateral ligament injury), in 4 patients due to neuromuscular ankle joint deformities, and in 4 patients due to rheumatoid arthritis. Results: Fusion occurred in 23 joints (92%) over an average of 12 weeks (range 6 to 18 weeks). Ankle arthrodesis was not achieved in 2 joints (8%), both in post-pilon fracture patients. The correct foot alignment was not achieved in 4 feet (16%). None of the treated patients required hardware removal. Conclusion: The presented technique was effective in achieving a high fusion rate in a variety of diseases, decreasing intra- and post-operative hardware complications while maintaining adequate bone stability. PMID:28400871

  10. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis.

    PubMed

    Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Pellizzer, Eduardo Piza

    2014-12-01

    The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10, 12.5, 15 mm - crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-D models. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises' criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maximum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio=30.1% and C/I 1:1 to 1:1.5 ratio=46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio=30% and C/I 1:1 to 1:1.5 ratio=51.5%). Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Less invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion.

    PubMed

    Korovessis, Panagiotis; Vardakastanis, Konstantinos; Repantis, Thomas; Vitsas, Vasilios

    2014-04-01

    The aim of this clinical study was to report on the efficacy in reduction and safety in PMMA leakage of a novel vertebral augmentation technique with PEEK and PMMA, together with pedicle screws in the treatment of fresh vertebral fractures in young adults. Twenty consecutive young adults aged 45 ± 11 years with fresh burst A3/AO or severely compressed A2/AO fractures underwent via a less invasive posterior approach one-staged reduction with a novel augmentation implant and PMMA plus 3-vertebrae pedicle screw fixation and fusion. Radiologic parameters as segmental kyphosis (SKA), anterior (AVBHr) and posterior vertebral body height ratio (PVBHr), spinal canal encroachment (SCE), cement leakage and functional parameters as VAS, SF-36 were measured pre- and post-operatively. Hybrid construct restored AVBHr (P < 0.000), PVBHr (P = 0.02), SKA (P = 0.015), SCE (P = 0.002) without loss of correction at an average follow-up of 17 months. PMMA leakage occurred in 3 patients (3 vertebrae) either anteriorly to the fractured vertebral body or to the adjacent disc, but in no case to the spinal canal. Two pedicle screws were malpositioned (one medially, one laterally to the pedicle at the fracture level) without neurologic sequelae. Solid posterolateral spinal fusion occurred 8-10 months post-operatively. Pre-operative VAS and SF-36 scores improved post-operatively significantly. This study showed that this novel vertebral augmentation technique using PEEK implant and PMMA reduces and stabilizes via less invasive technique A2 and A3 vertebral fractures without loss of correction and leakage to the spinal canal.

  12. End-threaded intramedullary positive profile screw ended self-tapping pin (Admit pin) - A cost-effective novel implant for fixing canine long bone fractures.

    PubMed

    Chanana, Mitin; Kumar, Adarsh; Tyagi, Som Prakash; Singla, Amit Kumar; Sharma, Arvind; Farooq, Uiase Bin

    2018-02-01

    The current study was undertaken to evaluate the clinical efficacy of end-threaded intramedullary pinning for management of various long bone fractures in canines. This study was conducted in two phases, managing 25 client-owned dogs presented with different fractures. The technique of application of end-threaded intramedullary pinning in long bone fractures was initially standardized in 6 clinical patients presented with long bone fractures. In this phase, end-threaded pins of different profiles, i.e., positive and negative, were used as the internal fixation technique. On the basis of results obtained from standardization phase, 19 client-owned dogs clinically presented with different fractures were implanted with end-threaded intramedullary positive profile screw ended self-tapping pin in the clinical application phase. The patients, allocated randomly in two groups, when evaluated postoperatively revealed slight pin migration in Group-I (negative profile), which resulted in disruption of callus site causing delayed union in one case and large callus formation in other two cases whereas no pin migration was observed in Group-II (positive profile). Other observations in Group-I was reduced muscle girth and delayed healing time as compared to Group-II. In clinical application, phase 21 st and 42 nd day post-operative radiographic follow-up revealed no pin migration in any of the cases, and there was no bone shortening or fragment collapse in end-threaded intramedullary positive profile screw ended self-tapping pin. The end-threaded intramedullary positive profile screw ended self-tapping pin used for fixation of long bone fractures in canines can resist pin migration, pin breakage, and all loads acting on the bone, i.e., compression, tension, bending, rotation, and shearing to an extent with no post-operative complications.

  13. Reciprocating and Screw Compressor semi-empirical models for establishing minimum energy performance standards

    NASA Astrophysics Data System (ADS)

    Javed, Hassan; Armstrong, Peter

    2015-08-01

    The efficiency bar for a Minimum Equipment Performance Standard (MEPS) generally aims to minimize energy consumption and life cycle cost of a given chiller type and size category serving a typical load profile. Compressor type has a significant chiller performance impact. Performance of screw and reciprocating compressors is expressed in terms of pressure ratio and speed for a given refrigerant and suction density. Isentropic efficiency for a screw compressor is strongly affected by under- and over-compression (UOC) processes. The theoretical simple physical UOC model involves a compressor-specific (but sometimes unknown) volume index parameter and the real gas properties of the refrigerant used. Isentropic efficiency is estimated by the UOC model and a bi-cubic, used to account for flow, friction and electrical losses. The unknown volume index, a smoothing parameter (to flatten the UOC model peak) and bi-cubic coefficients are identified by curve fitting to minimize an appropriate residual norm. Chiller performance maps are produced for each compressor type by selecting optimized sub-cooling and condenser fan speed options in a generic component-based chiller model. SEER is the sum of hourly load (from a typical building in the climate of interest) and specific power for the same hourly conditions. An empirical UAE cooling load model, scalable to any equipment capacity, is used to establish proposed UAE MEPS. Annual electricity use and cost, determined from SEER and annual cooling load, and chiller component cost data are used to find optimal chiller designs and perform life-cycle cost comparison between screw and reciprocating compressor-based chillers. This process may be applied to any climate/load model in order to establish optimized MEPS for any country and/or region.

  14. Mechanistic modeling of modular co-rotating twin-screw extruders.

    PubMed

    Eitzlmayr, Andreas; Koscher, Gerold; Reynolds, Gavin; Huang, Zhenyu; Booth, Jonathan; Shering, Philip; Khinast, Johannes

    2014-10-20

    In this study, we present a one-dimensional (1D) model of the metering zone of a modular, co-rotating twin-screw extruder for pharmaceutical hot melt extrusion (HME). The model accounts for filling ratio, pressure, melt temperature in screw channels and gaps, driving power, torque and the residence time distribution (RTD). It requires two empirical parameters for each screw element to be determined experimentally or numerically using computational fluid dynamics (CFD). The required Nusselt correlation for the heat transfer to the barrel was determined from experimental data. We present results for a fluid with a constant viscosity in comparison to literature data obtained from CFD simulations. Moreover, we show how to incorporate the rheology of a typical, non-Newtonian polymer melt, and present results in comparison to measurements. For both cases, we achieved excellent agreement. Furthermore, we present results for the RTD, based on experimental data from the literature, and found good agreement with simulations, in which the entire HME process was approximated with the metering model, assuming a constant viscosity for the polymer melt. Copyright © 2014. Published by Elsevier B.V.

  15. COMPRESSIVE FATIGUE IN TITANIUM DENTAL IMPLANTS SUBMITTED TO FLUORIDE IONS ACTION

    PubMed Central

    Ribeiro, Ana Lúcia Roselino; Noriega, Jorge Roberto; Dametto, Fábio Roberto; Vaz, Luís Geraldo

    2007-01-01

    The aim of this study was to assess the influence of a fluoridated medium on the mechanical properties of an internal hexagon implant-abutment set, by means of compression, mechanical cycling and metallographic characterization by scanning electronic microscopy. Five years of regular use of oral hygiene with a sodium fluoride solution content of 1500 ppm were simulated, immersing the samples in this medium for 184 hours, with the solutions being changed every 12 hours. Data were analyzed at a 95% confidence level with Fisher's exact test. After the action of fluoride ions, a negative influence occurred in the mechanical cycling test performed in a servohydraulic machine (Material Test System-810) set to a frequency of 15 Hz with 100,000 cycles and programmed to 60% of the maximum resistance of static compression test. The sets tended to fracture by compression on the screw, characterized by mixed ruptures with predominance of fragile fracture, as observed by microscopy. An evidence of corrosion by pitting on sample surfaces was found after the fluoride ions action. It may be concluded that prolonged contact with fluoride ions is harmful to the mechanical properties of commercially pure titanium structures. PMID:19089148

  16. Minimally invasive repair of pectus carinatum and how to deal with complications

    PubMed Central

    Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient’s malformation. This molding is done using benders designed as part of the procedure. PMID:29078492

  17. Minimally invasive repair of pectus carinatum and how to deal with complications.

    PubMed

    Abramson, Horacio; Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient's malformation. This molding is done using benders designed as part of the procedure.

  18. Static compression down-regulates N-cadherin expression and facilitates loss of cell phenotype of nucleus pulposus cells in a disc perfusion culture.

    PubMed

    Zhou, Haibo; Shi, Jianmin; Zhang, Chao; Li, Pei

    2018-02-28

    Mechanical compression often induces degenerative changes of disc nucleus pulposus (NP) tissue. It has been indicated that N-cadherin (N-CDH)-mediated signaling helps to preserve the NP cell phenotype. However, N-CDH expression and the resulting NP-specific phenotype alteration under the static compression and dynamic compression remain unclear. To study the effects of static compression and dynamic compression on N-CDH expression and NP-specific phenotype in an in vitro disc organ culture. Porcine discs were organ cultured in a self-developed mechanically active bioreactor for 7 days and subjected to static or dynamic compression (0.4 MPa for 2 h once per day). The noncompressed discs were used as controls. Compared with the dynamic compression, static compression significantly down-regulated the expression of N-CDH and NP-specific markers (laminin, brachyury, and keratin 19); decreased the Alcian Blue staining intensity, glycosaminoglycan and hydroxyproline contents; and declined the matrix macromolecule (aggrecan and collagen II) expression. Compared with the dynamic compression, static compression causes N-CDH down-regulation, loss of NP-specific phenotype, and the resulting decrease in NP matrix synthesis. © 2018 The Author(s).

  19. [Application of anterior percutaneous screw fixation in treatment of odontoid process fractures in aged people].

    PubMed

    Luo, Peng; Dou, Hai-cheng; Ni, Wen-fei; Huang, Qi-shan; Wang, Xiang-yang; Xu, Hua-zi; Chi, Yong-long

    2011-03-01

    To explore the efficacy of anterior percutaneous screw fixation in the treatment of odontoid process fractures in aged people. From February 2001 to April 2009, 15 elderly patients with odontoid fracture were treated with anterior percutaneous screw fixation,including 13 males and 2 females; the average age was 69.3 years (ranged, 60 to 86 years). According to Anderson classification, there were 10 patients with type II fractures (type II A in 7 cases, type II B in 3 cases, based on Eysel and Roosen classification), 4 patients with shallow type III fractures, 1 patient with deep type III fractures. Thirteen patients were fresh fractures, 2 patients were obsolete fractures. All patients had varying degrees of neck or shoulder pain, and limit activity of neck. There were 4 patients with neural symptoms including 2 grade D and 2 grade C according to Frankel classification. All the patients were followed up and were assessed by radiology. Clinical examination included neck activity, neurological function and the degree of neck pain. Radiology examinations including anteroposterior, lateral, open mouth position and flexion-extension radiographs of cervical vertebra were performed. After surgery, all patients were followed up,and the duration ranged from 6 to 60 months (averaged 31.3 months). Two patients died of other diseases during the follow-up period (18 and 22 months after surgery respectively). All patients got satisfactory results, and all screws were in good position. As the screw was too long, esophagus was compressed by screw tail in one case. One case showed fibrous union, 12 cases had achieved solid bony union, 2 cases showed nonunion without clinical symptoms. The rotation of neck in 3 cases was mildly limited,the neck function of the remaining patients were normal. Four patients with symptoms nerve injuries improved after operation (Frankel E in 3 cases, Frankel D in 1 case). The symptom of neck pain had a significant improvement after surgery (P < 0.001). The VAS score decreased from preoperative (6.07 +/- 1.44) (4 to 8 scores),to postoperative (1.13 +/- 0.92) (0 to 3 scores). And there were no severe postoperative complications. The anterior percutaneous screw fixation is less traumatic than conventional approaches for aged people in dealing with odontoid process fractures. Most patients will achieve satisfactory clinical results, as long as the general conditions of them are comprehensively assess. However, this procedure should not be used in patients with comminuted odontoid fractures or severe osteoporosis.

  20. Use of a continuous twin screw granulation and drying system during formulation development and process optimization.

    PubMed

    Vercruysse, J; Peeters, E; Fonteyne, M; Cappuyns, P; Delaet, U; Van Assche, I; De Beer, T; Remon, J P; Vervaet, C

    2015-01-01

    Since small scale is key for successful introduction of continuous techniques in the pharmaceutical industry to allow its use during formulation development and process optimization, it is essential to determine whether the product quality is similar when small quantities of materials are processed compared to the continuous processing of larger quantities. Therefore, the aim of this study was to investigate whether material processed in a single cell of the six-segmented fluid bed dryer of the ConsiGma™-25 system (a continuous twin screw granulation and drying system introduced by GEA Pharma Systems, Collette™, Wommelgem, Belgium) is predictive of granule and tablet quality during full-scale manufacturing when all drying cells are filled. Furthermore, the performance of the ConsiGma™-1 system (a mobile laboratory unit) was evaluated and compared to the ConsiGma™-25 system. A premix of two active ingredients, powdered cellulose, maize starch, pregelatinized starch and sodium starch glycolate was granulated with distilled water. After drying and milling (1000 μm, 800 rpm), granules were blended with magnesium stearate and compressed using a Modul™ P tablet press (tablet weight: 430 mg, main compression force: 12 kN). Single cell experiments using the ConsiGma™-25 system and ConsiGma™-1 system were performed in triplicate. Additionally, a 1h continuous run using the ConsiGma™-25 system was executed. Process outcomes (torque, barrel wall temperature, product temperature during drying) and granule (residual moisture content, particle size distribution, bulk and tapped density, hausner ratio, friability) as well as tablet (hardness, friability, disintegration time and dissolution) quality attributes were evaluated. By performing a 1h continuous run, it was detected that a stabilization period was needed for torque and barrel wall temperature due to initial layering of the screws and the screw chamber walls with material. Consequently, slightly deviating granule and tablet quality attributes were obtained during the start-up phase of the 1h run. For the single cell runs, granule and tablet properties were comparable with results obtained during the second part of the 1h run (after start-up). Although deviating granule quality (particle size distribution and Hausner ratio) was observed due to the divergent design of the ConsiGma™-1 unit and the ConsiGma™-25 system (horizontal set-up) used in this study, tablet quality produced from granules processed with the ConsiGma™-1 system was predictive for tablet quality obtained during continuous production using the ConsiGma™-25 system. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Sagittal Plane Correction Using the Lateral Transpsoas Approach: A Biomechanical Study on the Effect of Cage Angle and Surgical Technique on Segmental Lordosis.

    PubMed

    Melikian, Rojeh; Yoon, Sangwook Tim; Kim, Jin Young; Park, Kun Young; Yoon, Caroline; Hutton, William

    2016-09-01

    Cadaveric biomechanical study. To determine the degree of segmental correction that can be achieved through lateral transpsoas approach by varying cage angle and adding anterior longitudinal ligament (ALL) release and posterior element resection. Lordotic cage insertion through the lateral transpsoas approach is being used increasingly for restoration of sagittal alignment. However, the degree of correction achieved by varying cage angle and ALL release and posterior element resection is not well defined. Thirteen lumbar motion segments between L1 and L5 were dissected into single motion segments. Segmental angles and disk heights were measured under both 50 N and 500 N compressive loads under the following conditions: intact specimen, discectomy (collapsed disk simulation), insertion of parallel cage, 10° cage, 30° cage with ALL release, 30° cage with ALL release and spinous process (SP) resection, 30° cage with ALL release, SP resection, facetectomy, and compression with pedicle screws. Segmental lordosis was not increased by either parallel or 10° cages as compared with intact disks, and contributed small amounts of lordosis when compared with the collapsed disk condition. Placement of 30° cages with ALL release increased segmental lordosis by 10.5°. Adding SP resection increased lordosis to 12.4°. Facetectomy and compression with pedicle screws further increased lordosis to approximately 26°. No interventions resulted in a decrease in either anterior or posterior disk height. Insertion of a parallel or 10° cage has little effect on lordosis. A 30° cage insertion with ALL release resulted in a modest increase in lordosis (10.5°). The addition of SP resection and facetectomy was needed to obtain a larger amount of correction (26°). None of the cages, including the 30° lordotic cage, caused a decrease in posterior disk height suggesting hyperlordotic cages do not cause foraminal stenosis. N/A.

  2. Operative treatment of sternal fractures.

    PubMed

    Al-Qudah, Abdullah

    2006-10-01

    Four patients with displaced sternal fractures complained of intractable pain following road traffic accidents. They all had bone deformities, but only one had associated traumatic injuries. All patients underwent operative reduction and fixation of the fractured sternum using a T-shaped compression-tension stainless steel plate and screws. Pain relief was often dramatic and all patients progressed to sternal union. None required reoperation. No infections occurred. Two plates have subsequently been removed. On follow-up, all patients had excellent results. Sternal plating, which is based on the tension-band principle, is an effective treatment for displaced sternal fractures.

  3. Ultrasonic Structural Health Monitoring to Assess the Integrity of Spinal Growing Rods In Vitro.

    PubMed

    Oetgen, Matthew E; Goodley, Addison; Yoo, Byungseok; Pines, Darryll J; Hsieh, Adam H

    2016-01-01

    Rod fracture is a common complication of growing rods and can result in loss of correction, patient discomfort, and unplanned revision surgery. The ability to quantitate rod integrity at each lengthening would be advantageous to avoid this complication. We investigate the feasibility of applying structural health monitoring to evaluate the integrity of growing rods in vitro. Single-rod titanium 4.5-mm growing rod constructs (n = 9), one screw proximally and one distally connected by in-line connectors, were assembled with pedicle screws fixed in polyethylene blocks. Proximal and distal ends were loaded and constructs subjected to cyclic axial compression (0-100 N at 1 Hz), with incrementally increasing maximum compressive loads of 10 N every 9k cycles until failure. Four piezoceramic transducers (PZTs) were mounted along the length the constructs to interrogate the integrity of the rods with an ultrasonic, guided lamb wave approach. Every 9k cycles, an 80 V excitatory voltage was applied to a PZT to generate high-frequency vibrations, which, after propagating through the construct, was detected by the remaining PZTs. Amplitude differences between pre- and postload waveform signals were calculated until rod failure. Average construct lifetime was 88,991 ± 13,398 cycles. All constructs failed due to rod fracture within 21 mm (mean = 15 ± 4.5 mm) of a screw or connector. Amplitude differences between pre- and postload increased in a stepwise fashion as constructs were cycled. Compared to baseline, we found a 1.8 ± 0.6-fold increase in amplitude 18k cycles before failure, a 2.2 ± 1.0-fold increase in amplitude 9k cycles before failure, and a 2.75 ± 1.5-fold increase in amplitude immediately before rod fracture. We describe a potential method for assessing the structural integrity of growing rods using ultrasonic structural health monitoring. These preliminary data demonstrate the ability of periodic rod assessment to detect structural changes in cycled growing rods, which appear to correspond to subclinical rod fatigue before rod fracture. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  4. Hierarchical assembly strategy and multiscale structural origin of exceptional mechanical performance in nacre

    NASA Astrophysics Data System (ADS)

    Huang, Zaiwang

    Nacre (mother of pearl) is a self-assembled hierarchical nanocomposite in possession of exquisite multiscale architecture and exceptional mechanical properties. Previous work has shown that the highly-ordered brick-mortar-like structure in nacre is assembled via epitaxial growth and the aragonite platelets are pure single-crystals. Our results challenge this conclusion and propose that nacre's individual aragonite platelets are constructed with highly-aligned aragonite nanoparticles mediated by screw dislocation and amorphous aggregation. The underlying physics mechanism why the aragonite nanoparticles choose highly-oriented attachment as its crystallization pathway is rationalized in terms of thermodynamics. The aragonite nanoparticle order-disorder transformation can be triggered by high temperature and mechanical deformation, which in turn confirms that the aragonite nanoparticles are basic building blocks for aragonite platelets. Particularly fascinating is the fracture toughness enhancement of nacre through exquisitely collecting mechanically inferior calcium carbonate (CaCO3) and biomolecules. The sandwich-like microarchitecture with a geometrically staggered arrangement can induce crack deflection along its biopolymer interface, thus significantly enhancing nacre's fracture toughness. Our new findings ambiguously demonstrate that, aside from crack deflection, the advancing crack can invade aragonite platelet, leaving a zigzag crack propagation pathway. These unexpected experimental observations disclose, for the first time, the inevitable structural role of aragonite platelets in enhancing nacre's fracture toughness. Simultaneously, the findings that the crack propagates in a zigzag manner within individual aragonite platelets overturn the previously well-established wisdom that considers aragonite platelets as brittle single-crystals. Moreover, we investigated the dynamical mechanical response of nacre under unixial compression. Our results show that the high strain rate sensitivity reaching ˜0.1 can be directly related to the localized plastic activation volume. Nacre's hierarchical energy-dissipation mechanism under dynamic compression loading comes from a mechanical optimization derived from its inherently multiscale functional structure design.

  5. Bone repair in mandibular body osteotomy after using 2.0 miniplate system – histological and histometric analysis in dogs

    PubMed Central

    Sverzut, Cássio Edvard; Lucas, Marina Amaral; Sverzut, Alexander Tadeu; Trivellato, Alexandre Elias; Beloti, Marcio Mateus; Rosa, Adalberto Luiz; de Oliveira, Paulo Tambasco

    2008-01-01

    The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft für Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles. PMID:18336526

  6. Use of CFD to predict trapped gas excitation as source of vibration and noise in screw compressors

    NASA Astrophysics Data System (ADS)

    Willie, James

    2017-08-01

    This paper investigates the source of noise in oil free screw compressors mounted on highway trucks and driven by a power take-off (PTO) transmission system. Trapped gas at the discharge side is suggested as possible source of the excitation of low frequency torsional resonance in these compressors that can lead to noise and vibration. Measurements and lumped mass torsional models have shown low frequency torsional resonance in the drive train of these compressors when they are mounted on trucks. This results in high torque peak at the compressor input shaft and in part to pulsating noise inside the machine. The severity of the torque peak depends on the amplitude of the input torque fluctuation from the drive (electric motor or truck engine). This in turn depends on the prop-shaft angle. However, the source of the excitation of this low torsional resonance inside the machine is unknown. Using CFD with mesh motion at every 1° rotation of the rotors, it is shown that the absence of a pressure equalizing chamber at the discharge can lead to trapped gas creation, which can lead to over-compression, over-heating of the rotors, and to high pressure pulsations at the discharge. Over-compression can lead to shock wave generation at the discharge plenum and the pulsation in pressure can lead to noise generation. In addition, if the frequency of the pressure pulsation in the low frequency range coincides with the first torsional frequency of the drive train the first torsional resonance mode can be excited.

  7. Intramedullary compressive nail fixation for the treatment of severe Charcot deformity of the ankle and rear foot.

    PubMed

    Caravaggi, Carlo; Cimmino, Marzio; Caruso, Sebastiano; Dalla Noce, Sergio

    2006-01-01

    Involvement of the ankle joint in Charcot osteoarthropathy may be associated with severe instability and fracture or collapse of the talus. Recalcitrant ulceration may result over the lateral malleolus, increasing the risk of major amputation. This study evaluated ankle arthrodesis with a compressive intramedullary nail in 14 patients with diabetes affected by Charcot of the ankle. The mean patient age was 58 +/- 12 years, and the mean duration of diabetes was 17 +/- 5 years. Transcutaneous oxygen pressures were > or = 50 mm Hg in all patients, indicating a good distal blood supply. A below-knee amputation had previously been suggested because of severe ankle joint instability. None of the patients were able to walk without a brace. Four patients had an ulceration that had healed before the index procedure. All procedures were performed in the quiescent phase of the disease. After a mean follow-up of 18 +/- 4 months, 10 patients (71.4%) achieved a solid arthrodesis, returning to walking with protective shoes. Three patients (21.4%) developed breakage of the calcaneus screws, necessitating removal of the screws in 2 cases and removal of the entire nail in 2 cases. These 3 patients went on to fibrous union that allowed walking with a brace. One patient (7.2%) required a below-knee amputation because of postoperative osteomyelitis of the distal tibia. The data from our study demonstrate a high rate of limb salvage (92.8%), suggesting that this device is safe and effective in the treatment of Charcot arthropathy of the ankle.

  8. Influence of dislocation strain fields on the diffusion of interstitial iron impurities in silicon

    NASA Astrophysics Data System (ADS)

    Ziebarth, Benedikt; Mrovec, Matous; Elsässer, Christian; Gumbsch, Peter

    2015-09-01

    The efficiency of silicon (Si)-based solar cells is strongly affected by crystal defects and impurities. Metallic impurities, in particular interstitial iron (Fe) atoms, cause large electric losses because they act as recombination centers for photogenerated charge carriers. Here, we present a systematic first-principles density functional theory (DFT) study focusing on the influence of hydrostatic, uniaxial, and shear strains on the thermodynamic stability and the diffusivity of Fe impurities in crystalline Si. Our calculations show that the formation energy of neutral Fe interstitials in tetrahedral interstitial sites is almost unaffected by uniform deformations of the Si crystal up to strains of 5%. In contrast, the migration barrier varies significantly with strain, especially for hydrostatic deformation. In order to determine effective diffusion coefficients for different strain states, a kinetic Monte Carlo (kMC) model was set up based on the activation energy barriers and frequency factors obtained from the DFT simulations. By using the strain dependence of the migration barrier, we examined the migration of Fe interstitials in the vicinity of perfect 1 /2 <110 > screw and 60∘ mixed dislocations, and 1 /6 <112 > 90∘ and 30∘ partial dislocations. While the strain field of the perfect screw dislocation always enhances the local Fe diffusion, the existence of tensile and compressive regions around the 60∘ mixed dislocation results in a strong anisotropic diffusion profile with significantly faster and slower diffusivities on its tensile and compressive sides. The influences of the partial dislocations are qualitatively similar to that of the 60∘ mixed dislocation.

  9. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    PubMed

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  10. The effect of excision of the posterior arch of C1 on C1/C2 fusion using transarticular screws.

    PubMed

    Chang, K C; Samartzis, D; Fuego, S M; Dhatt, S S; Wong, Y W; Cheung, W Y; Luk, K D K; Cheung, K M C

    2013-07-01

    Transarticular screw fixation with autograft is an established procedure for the surgical treatment of atlantoaxial instability. Removal of the posterior arch of C1 may affect the rate of fusion. This study assessed the rate of atlantoaxial fusion using transarticular screws with or without removal of the posterior arch of C1. We reviewed 30 consecutive patients who underwent atlantoaxial fusion with a minimum follow-up of two years. In 25 patients (group A) the posterior arch of C1 was not excised (group A) and in five it was (group B). Fusion was assessed on static and dynamic radiographs. In selected patients CT imaging was also used to assess fusion and the position of the screws. There were 15 men and 15 women with a mean age of 51.2 years (23 to 77) and a mean follow-up of 7.7 years (2 to 11.6). Stable union with a solid fusion or a stable fibrous union was achieved in 29 patients (97%). In Group A, 20 patients (80%) achieved a solid fusion, four (16%) a stable fibrous union and one (4%) a nonunion. In Group B, stable union was achieved in all patients, three having a solid fusion and two a stable fibrous union. There was no statistically significant difference between the status of fusion in the two groups. Complications were noted in 12 patients (40%); these were mainly related to the screws, and included malpositioning and breakage. The presence of an intact or removed posterior arch of C1 did not affect the rate of fusion in patients with atlantoaxial instability undergoing C1/C2 fusion using transarticular screws and autograft.

  11. In Vivo Evaluation of Immediately Loaded Stainless Steel and Titanium Orthodontic Screws in a Growing Bone

    PubMed Central

    Gritsch, Kerstin; Laroche, Norbert; Bonnet, Jeanne-Marie; Exbrayat, Patrick; Morgon, Laurent; Rabilloud, Muriel; Grosgogeat, Brigitte

    2013-01-01

    The present work intends to evaluate the use of immediate loaded orthodontic screws in a growing model, and to study the specific bone response. Thirty-two screws (half of stainless steel and half of titanium) were inserted in the alveolar bone of 8 growing pigs. The devices were immediately loaded with a 100 g orthodontic force. Two loading periods were assessed: 4 and 12 weeks. Both systems of screws were clinically assessed. Histological observations and histomorphometric analysis evaluated the percent of “bone-to-implant contact” and static and dynamic bone parameters in the vicinity of the devices (test zone) and in a bone area located 1.5 cm posterior to the devices (control zone). Both systems exhibit similar responses for the survival rate; 87.5% and 81.3% for stainless steel and titanium respectively (p = 0.64; 4-week period), and 62.5% and 50.0% for stainless steel and titanium respectively (p = 0.09; 12-week period). No significant differences between the devices were found regarding the percent of “bone-to-implant contact” (p = 0.1) or the static and dynamic bone parameters. However, the 5% threshold of “bone-to-implant contact” was obtained after 4 weeks with the stainless steel devices, leading to increased survival rate values. Bone in the vicinity of the miniscrew implants showed evidence of a significant increase in bone trabecular thickness when compared to bone in the control zone (p = 0.05). In our study, it is likely that increased trabecular thickness is a way for low density bone to respond to the stress induced by loading. PMID:24124540

  12. The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw.

    PubMed

    Sedighi, Ali; Sales, Jafar Ganjpour; Alavi, Sahar

    2012-11-02

    Intertrochanteric fractures (ITFs) are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS) has gained wide acceptance. This current study was designed to assess positive predictive value of tip-to-apex distance (TAD) index in the prognosis of patients treated with DHS. The study was designed according to a descriptive-analytic protocol, made up of 100 cases of ITFs caused by falling, treated in the Shohada Orthopedic Center, Tabriz, Iran. All patients underwent lateral and antero-posterior hip X-ray to measure TAD index. The cohort was followed for three months after DHS placement. Of a total of 100 cases (53 male, 47 female) with a mean age of 76.7 years (range 29-100 years), 43% had grade 4, 29% grade 3, 21% grade 5, 5% grade 2 and 2% grade 6 osteoporosis. The screw position was postero-inferior in 57%, central in 40% and superior in 3% of patients. Minimum and maximum TAD index were 20 and 28 mm, respectively. Mean TAD was 23.5 mm. There were no post-operative complications in 84% of cases. Screw failure was the most common complication in the remaining 16% of patients. The study shows a statistically significant correlation between TAD index and cut-off rate in patients with intertrochanteric fractures of femoral bone treated by DHS. This validates the use of TAD index in determining the prognosis of patients treated by DHS.

  13. Revision Tibiotalocalcaneal Arthrodesis With a Pseudoelastic Intramedullary Nail.

    PubMed

    Latt, L Daniel; Smith, Kathryn Elizabeth; Dupont, Kenneth Michael

    2017-02-01

    Hindfoot (tibiotalocalcaneal or TTC) arthrodesis is commonly used to treat concomitant arthritis of the ankle and subtalar joints. Simultaneous fusion of both joints can be difficult to achieve especially in patients with impaired healing due to smoking, diabetes mellitus, or Charcot neuroarthropathy. Conventional intramedullary fixation devices allow for compression to be applied at the time of surgery, but this compression can be lost due to bone resorption or settling, leading to impaired healing. In contrast, the novel pseudoelastic intramedullary nail is designed to maintain compression at the arthrodesis sites throughout the healing process by the use of an internal pseudoelastic element. We present 2 cases of revision TTC arthrodesis using the pseudoelastic intramedullary nail. In the first case, an 80-year-old diabetic man with previous ankle and failed subtalar fusion with screws underwent revision TTC arthrodesis. In the second case, a 66-year-old man with Charcot neuroarthropathy and a failed TTC arthrodesis with a static intramedullary nail underwent revision tibiotalar arthrodesis. In both cases, computed tomography scan demonstrated successful union and patients were allowed full weight bearing by 3 months after surgery. These cases provide early evidence that sustained compression via an intramedullary nail can lead to rapid successful hindfoot fusion when standard approaches have failed. Therapeutic, Level IV: Case study.

  14. Dynamic compressive properties obtained from a split Hopkinson pressure bar test of Boryeong shale

    NASA Astrophysics Data System (ADS)

    Kang, Minju; Cho, Jung-Woo; Kim, Yang Gon; Park, Jaeyeong; Jeong, Myeong-Sik; Lee, Sunghak

    2016-09-01

    Dynamic compressive properties of a Boryeong shale were evaluated by using a split Hopkinson pressure bar, and were compared with those of a Hwangdeung granite which is a typical hard rock. The results indicated that the dynamic compressive loading reduced the resistance to fracture. The dynamic compressive strength was lower in the shale than in the granite, and was raised with increasing strain rate by microcracking effect as well as strain rate strengthening effect. Since the number of microcracked fragments increased with increasing strain rate in the shale having laminated weakness planes, the shale showed the better fragmentation performance than the granite at high strain rates. The effect of transversely isotropic plane on compressive strength decreased with increasing strain rate, which was desirable for increasing the fragmentation performance. Thus, the shale can be more reliably applied to industrial areas requiring good fragmentation performance as the striking speed of drilling or hydraulic fracturing machines increased. The present dynamic compressive test effectively evaluated the fragmentation performance as well as compressive strength and strain energy density by controlling the air pressure, and provided an important idea on which rock was more readily fragmented under dynamically processing conditions such as high-speed drilling and blasting.

  15. Electrical apparatus lockout device

    DOEpatents

    Gonzales, Rick

    1999-01-01

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards.

  16. Development and Optimization of a Wet Granulation Process at Elevated Temperature for a Poorly Compactible Drug Using Twin Screw Extruder for Continuous Manufacturing.

    PubMed

    Meena, Anuprabha K; Desai, Divyakant; Serajuddin, Abu T M

    2017-02-01

    The objective of this study was to enhance tabletability of a poorly compactible drug, acetaminophen, by wet granulation using twin screw extruder at high temperature. It was desired that there would be minimum amounts of excipients used and the granules obtained after extrusion would be dry and fall within a size range suitable for tableting without any further processing. Mixtures of acetaminophen (95%) with binders (5% povidone or partially pregelatinized starch) were wet granulated through twin screw extruder at 70°C by adding 7% w/w water. The process had a short granulation time (<1 min), and, on account of the elevated processing temperature used, no drying after extrusion was needed. By optimizing formulation and processing parameters, >90% granules in the size range of 125 to 1000 μm (<3% above 1000 μm and <7% below 125 μm) were obtained without any milling. When the granules were compressed by adding 1% disintegrant and 0.5% lubricant extragranularly, tablets produced (93.6% drug load) had good mechanical strength having hardness >1.7 MPa, which was superior to that of tablets prepared by conventional high shear wet granulation. As the granules could be extruded continuously and did not require drying and milling, the method was amenable to continuous processing. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.

    PubMed

    Pelton, Kevin; Hofer, Jason K; Thordarson, David B

    2006-10-01

    Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.

  18. Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency: A Concise Follow-up, at a Minimum of 10 Years, of Previous Reports.

    PubMed

    Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G; Clark, Rachel E; Frankle, Mark A

    2017-11-15

    We previously evaluated 94 patients (96 shoulders) who underwent reverse shoulder arthroplasty using a central compressive screw with 5.0-mm peripheral locking screws for baseplate fixation and a center of rotation lateral to the glenoid as treatment for end-stage rotator cuff deficiency. The purpose of this study was to report updated results at a minimum follow-up of 10 years. Forty patients (42 shoulders) were available for clinical follow-up. In the patients available for study, implant survivorship, with the end point being revision for any reason, was 90.7%. Since our 5-year report, 2 patients underwent revision surgery; 1 patient sustained a periprosthetic fracture 7 years postoperatively and 1 patient had a dislocation because of chronic shoulder instability at 8 years postoperatively. At a minimum follow-up of 10 years, the patients continued to maintain their improved outcome scores and range of motion, which were comparable with earlier follow-up evaluations. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  19. Application of numerical grid generation for improved CFD analysis of multiphase screw machines

    NASA Astrophysics Data System (ADS)

    Rane, S.; Kovačević, A.

    2017-08-01

    Algebraic grid generation is widely used for discretization of the working domain of twin screw machines. Algebraic grid generation is fast and has good control over the placement of grid nodes. However, the desired qualities of grid which should be able to handle multiphase flows such as oil injection, may be difficult to achieve at times. In order to obtain fast solution of multiphase screw machines, it is important to further improve the quality and robustness of the computational grid. In this paper, a deforming grid of a twin screw machine is generated using algebraic transfinite interpolation to produce initial mesh upon which an elliptic partial differential equations (PDE) of the Poisson’s form is solved numerically to produce smooth final computational mesh. The quality of numerical cells and their distribution obtained by the differential method is greatly improved. In addition, a similar procedure was introduced to fully smoothen the transition of the partitioning rack curve between the rotors thus improving continuous movement of grid nodes and in turn improve robustness and speed of the Computational Fluid Dynamic (CFD) solver. Analysis of an oil injected twin screw compressor is presented to compare the improvements in grid quality factors in the regions of importance such as interlobe space, radial tip and the core of the rotor. The proposed method that combines algebraic and differential grid generation offer significant improvement in grid quality and robustness of numerical solution.

  20. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures.

    PubMed

    Gupta, Sameer; Kukreja, Sunil; Singh, Vivek

    2014-04-01

    To review the outcome of 60 patients who underwent valgus subtrochanteric osteotomy and its repositioning for un-united and neglected femoral neck fractures. 60 patients (mean age, 35 years) underwent valgus subtrochanteric osteotomy and repositioning of the osteotomy and fixation with a dynamic hip screw and a 135° single-angled barrel plate for closed un-united femoral neck fractures after failed internal fixation (n=27) or neglected (>3 weeks) fractures (n=33). The most common fracture type was transcervical (n=48), followed by subcapital (n=6) and basal (n=6). All patients had displaced femoral neck fractures (Garden types 3 and 4). According to the Pauwel angle, 45 fractures were type 2 (30º-70º) and 15 were type 3 (>70º). Patients were followed up for a mean of 3.5 (range, 2-7.5) years. The mean Pauwel angle of the fracture was corrected from 65° (range, 50°-89°) to 26° (range, 25°-28°). Bone union was achieved in 56 patients after a mean of 3.9 (range, 3-5.5) months. The mean Harris hip score improved from 65 to 87.5. Outcome was excellent in 30 patients, good in 24, and poor in 6. Four of the patients developed avascular necrosis; 2 of whom nonetheless achieved a good outcome. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135° single-angled barrel plate was effective treatment for un-united and neglected femoral neck fractures.

  1. Size effects on plasticity and fatigue microstructure evolution in FCC single crystals

    NASA Astrophysics Data System (ADS)

    El-Awady, Jaafar Abbas

    In aircraft structures and engines, fatigue damage is manifest in the progressive emergence of distributed surface cracks near locations of high stress concentrations. At the present time, reliable methods for prediction of fatigue crack initiation are not available, because the phenomenon starts at the atomic scale. Initiation of fatigue cracks is associated with the formation of Persistent slip bands (PSBs), which start at certain critical conditions inside metals with specific microstructure dimensions. The main objective of this research is to develop predictive computational capabilities for plasticity and fatigue damage evolution in finite volumes. In that attempt, a dislocation dynamics model that incorporates the influence of free and internal interfaces on dislocation motion is presented. The model is based on a self-consistent formulation of 3-D Parametric Dislocation Dynamics (PDD) with the Boundary Element method (BEM) to describe dislocation motion, and hence microscopic plastic flow in finite volumes. The developed computer models are bench-marked by detailed comparisons with the experimental data, developed at the Wright-Patterson Air Force Lab (WP-AFRL), by three dimensional large scale simulations of compression loading on micro-scale samples of FCC single crystals. These simulation results provide an understanding of plastic deformation of micron-size single crystals. The plastic flow characteristics as well as the stress-strain behavior of simulated micropillars are shown to be in general agreement with experimental observations. New size scaling aspects of plastic flow and work-hardening are identified through the use of these simulations. The flow strength versus the diameter of the micropillar follows a power law with an exponent equal to -0.69. A stronger correlation is observed between the flow strength and the average length of activated dislocation sources. This relationship is again a power law, with an exponent -0.85. Simulation results with and without the activation of cross-slip are compared. Discontinuous hardening is observed when cross-slip is included. Experimentally-observed size effects on plastic flow and work- hardening are consistent with a "weakest-link activation mechanism". In addition, the variations and periodicity of dislocation activation are analyzed using the Fast Fourier Transform (FFT). We then present models of localized plastic deformation inside Persistent Slip Band channels. We investigate the interaction between screw dislocations as they pass one another inside channel walls in copper. The model shows the mechanisms of dislocation bowing, dipole formation and binding, and dipole destruction as screw dislocations pass one another. The mechanism of (dipole passing) is assessed and interpreted in terms of the fatigue saturation stress. We also present results for the effects of the wall dipole structure on the dipole passing mechanism. The edge dislocation dipolar walls is seen to have an effect on the passing stress as well. It is shown that the passing stress in the middle of the channel is reduced by 11 to 23% depending on the initial configuration of the screw dislocations with respect to one another. Finally, from large scale simulations of the expansion process of the edge dipoles from the walls in the channel the screw dislocations in the PSB channels may not meet "symmetrically", i.e. precisely in the center of the channel but preferably a little on one or the other side. For this configuration the passing stress will be lowered which is in agreement to experimental observations.

  2. LOW-VELOCITY COMPRESSIBLE FLOW THEORY

    EPA Science Inventory

    The widespread application of incompressible flow theory dominates low-velocity fluid dynamics, virtually preventing research into compressible low-velocity flow dynamics. Yet, compressible solutions to simple and well-defined flow problems and a series of contradictions in incom...

  3. Opening wedge and anatomic-specific plates in foot and ankle applications.

    PubMed

    Kluesner, Andrew J; Morris, Jason B

    2011-08-01

    As surgeons continually push to improve techniques and outcomes, anatomic-specific and procedure-specific fixation options are becoming increasingly available. The unique size, shape, and function of the foot provide an ideal framework for the use of anatomic-specific plates. These distinctive plate characteristics range from anatomic contouring and screw placements to incorporated step-offs and wedges. By optimizing support, compression, and stabilization, patients may return to weight bearing and activity sooner, improving outcomes. This article discusses anatomic-specific plates and their use in forefoot and rearfoot surgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Ventriculostomy for acute hydrocephalus in critically ill patients on the ICU--outcome analysis of two different procedures.

    PubMed

    Schödel, Petra; Proescholdt, Martin; Brawanski, Alexander; Bele, Sylvia; Schebesch, Karl-Michael

    2012-04-01

    Burr-hole trephine and insertion of an external ventricular drainage (EVD) is a common procedure in neurosurgical practice. In critically ill patients, the transport to the operating room, OR represents a major risk. Thus, the burr-hole trephine and implantation of an EVD is frequently performed on the Intensive Care Unit (ICU). Since 2004, we have applied two different procedures: the conventional method with a mechanical compressed air or an electric drill, and an alternative method with a manual twist drill, including fixation of the EVD in a skull screw (Bolt Kit, Raumedic AG, Germany). This study was designed to evaluate the outcome of both surgical procedures. In this retrospective analysis we included 166 consecutive patients with acute hydrocephalus due to intracranial hemorrhage that had been operated at our neurosurgical ICU in a six years interval. We reviewed the charts for gender and age, kind of surgical procedure, cerebrospinal fluid (CSF)-infections, duration of drainage, attempts of insertions, wound infections, misplacement rate, post-surgical hemorrhages, revisions, comorbidities and shunt-dependency. In 122 patients we applied the Bolt Kit System, in 44 patients the conventional method was performed. We found a significantly lower rate of CSF-infections and significantly fewer attempts of insertions in the Bolt Kit group (p = 0.002 and p = 0.001, respectively). The rate of wound infections, misplacement, revisions, shunt-dependency and the post-surgical hemorrhages did not differ significantly. Our data indicate that the manual drill and the skull screw are safe and feasible tools in the treatment of acute hydrocephalus. Presumably, the direct skin contact is causative for the higher rate of CSF-infections when the conventional method is performed. The skull screw guides the EVD into the ventricle without skin contact. The lower number of insertions needed may be due to the fact that the skull screw allows just one trajectory for the insertion of the EVD.

  5. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box.

    PubMed

    Harness, Neil G

    2016-03-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41-82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70-64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0-2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates.

  6. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box

    PubMed Central

    Harness, Neil G.

    2016-01-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41–82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70–64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0–2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates. PMID:26855830

  7. Kyphectomy for congenital kyphosis due to meningomyelocele: a case treated with a modified approach to skin healing.

    PubMed

    Kose, Kamil Cagri; Inanmaz, Mustafa Erkan; Uslu, Mustafa; Bal, Emre; Caliskan, Islam

    2012-06-01

    This study is a case report of a meningomyelocele patient with congenital kyphosis who was treated with kyphectomy and a special approach to soft tissue healing. The objective of this study is to show a step by step approach to surgical treatment and postoperative care of a meningomyelocele patient with congenital kyphosis. In meningomyelocele the incidence of kyphosis is around 12-20%. It may cause recurrent skin ulcerations, impaired sitting balance and respiratory compromise. Kyphectomy has first been described by Sharrard. This surgery is prone to complications including pseudoarthrosis, skin healing problems, recurrence of deformity and deep infections. A 15-year-old male presented with congenital kyphosis due to meningomyelocele. He had back pain, deformity and bedsores at the apex of the deformity. The wound cultures showed Staphylococcus epidermidis colonisation at the apex. He was given appropriate antibiotic prophylaxis. During surgery, the apex of the deformity was exposed through a spindle-shaped incision. After instrumentation and excision of the apex, correction was carried out by cantilever technique. Two screws were inserted to the bodies of L3 and T11. After the operation, the skin was closed in a reverse cross fashion. He was sent to hyperbaric oxygen treatment for prevention of a subsequent skin infection and for rapid healing of skin flaps post operation. The patient's deformity was corrected from a preoperative Cobb angle of 135°-15° postoperative. The skin healed without any problems. Preoperative culture and appropriate antibiotic prophylaxis, spindle-shaped incision, reverse cross-skin closure and postoperative hyperbaric oxygen treatment can be useful adjuncts to treatment in congenital kyphosis patients with myelomeningocele to prevent postoperative wound healing and infection problems. Reduction screws and intracorporeal compression screws help to reduce the amount of screws and aid in corection of the deformity. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  8. Note: High-speed Z tip scanner with screw cantilever holding mechanism for atomic-resolution atomic force microscopy in liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reza Akrami, Seyed Mohammad; Miyata, Kazuki; Asakawa, Hitoshi

    High-speed atomic force microscopy has attracted much attention due to its unique capability of visualizing nanoscale dynamic processes at a solid/liquid interface. However, its usability and resolution have yet to be improved. As one of the solutions for this issue, here we present a design of a high-speed Z-tip scanner with screw holding mechanism. We perform detailed comparison between designs with different actuator size and screw arrangement by finite element analysis. Based on the design giving the best performance, we have developed a Z tip scanner and measured its performance. The measured frequency response of the scanner shows a flatmore » response up to ∼10 kHz. This high frequency response allows us to achieve wideband tip-sample distance regulation. We demonstrate the applicability of the scanner to high-speed atomic-resolution imaging by visualizing atomic-scale calcite crystal dissolution process in water at 2 s/frame.« less

  9. Comparative study of bearing loads for different twin screw compressor rotor configurations

    NASA Astrophysics Data System (ADS)

    Buckney, D.; Anderson, C.

    2017-08-01

    Designing rotor geometry is a critical stage in the design of a twin screw compressor which has a significant impact on: capacity; leakage characteristics; thermodynamics; rotor stiffness; dynamics; and loading on the bearings. The focus of this paper is on bearing loads. In order to design screw compressors that can operate at higher pressures the bearings quickly become a limiting factor. With the need to house the bearings adjacent to one another on each of the parallel rotor shafts at a given centre distance there is an inherent limit to the bearing geometry envelope. In this investigation the ‘rotor configuration’ refers to the rotor lobe combination, length to diameter ratio (L/D), and wrap angle. The geometry of the transverse rotor profiles is kept constant, as far as possible, allowing conclusions to be drawn based on a manageable number of variables. A procedure to calculate bearing specific loads based on results from a thermodynamic chamber model is presented and results for a range of rotor configurations are discussed.

  10. Screw withdrawal : a means to evaluate densities of in-situ wood members

    Treesearch

    Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis

    2003-01-01

    Dynamic modulus of elasticity (MOE) of a wood member is defined as the product of its density and square of stress wave speed. The dynamic MOE, which is highly correlated to the static MOE, is commonly used to estimate the load carrying capacity and serviceability of in-situ wood members. The stress wave speed can be estimated using ultrasonic, impact, or vibration...

  11. Mathematical modeling for resource and energy saving control of extruders in multi-assortment productions of polymeric films

    NASA Astrophysics Data System (ADS)

    Polosin, A. N.; Chistyakova, T. B.

    2018-05-01

    In this article, the authors describe mathematical modeling of polymer processing in extruders of various types used in extrusion and calender productions of film materials. The method consists of the synthesis of a static model for calculating throughput, energy consumption of the extruder, extrudate quality indices, as well as a dynamic model for evaluating polymer residence time in the extruder, on which the quality indices depend. Models are adjusted according to the extruder type (single-screw, reciprocating, twin-screw), its screw and head configuration, extruder’s work temperature conditions, and the processed polymer type. Models enable creating extruder screw configurations and determining extruder controlling action values that provide the extrudate of required quality while satisfying extruder throughput and energy consumption requirements. Model adequacy has been verified using polyolefins’ and polyvinylchloride processing data in different extruders. The program complex, based on mathematical models, has been developed in order to control extruders of various types in order to ensure resource and energy saving in multi-assortment productions of polymeric films. Using the program complex in the control system for the extrusion stage of the polymeric film productions enables improving film quality, reducing spoilage, lessening the time required for production line change-over to other throughput and film type assignment.

  12. Dynamic compression of rabbit adipose-derived stem cells transfected with insulin-like growth factor 1 in chitosan/gelatin scaffolds induces chondrogenesis and matrix biosynthesis.

    PubMed

    Li, Jianjun; Zhao, Qun; Wang, Enbo; Zhang, Chuanhui; Wang, Guangbin; Yuan, Quan

    2012-05-01

    Articular cartilage is routinely subjected to mechanical forces and growth factors. Adipose-derived stem cells (ASCs) are multi-potent adult stem cells and capable of chondrogenesis. In the present study, we investigated the comparative and interactive effects of dynamic compression and insulin-like growth factor-I (IGF-I) on the chondrogenesis of rabbit ASCs in chitosan/gelatin scaffolds. Rabbit ASCs with or without a plasmid overexpressing of human IGF-1 were cultured in chitosan/gelatin scaffolds for 2 days, then subjected to cyclic compression with 5% strain and 1 Hz for 4 h per day for seven consecutive days. Dynamic compression induced chondrogenesis of rabbit ASCs by activating calcium signaling pathways and up-regulating the expression of Sox-9. Dynamic compression plus IGF-1 overexpression up-regulated expression of chondrocyte-specific extracellular matrix genes including type II collagen, Sox-9, and aggrecan with no effect on type X collagen expression. Furthermore, dynamic compression and IGF-1 expression promoted cellular proliferation and the deposition of proteoglycan and collagen. Intracellular calcium ion concentration and peak currents of Ca(2+) ion channels were consistent with chondrocytes. The tissue-engineered cartilage from this process had excellent mechanical properties. When applied together, the effects achieved by the two stimuli (dynamic compression and IGF-1) were greater than those achieved by either stimulus alone. Our results suggest that dynamic compression combined with IGF-1 overexpression might benefit articular cartilage tissue engineering in cartilage regeneration. Copyright © 2011 Wiley Periodicals, Inc.

  13. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    PubMed

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p <.001) for all comparisons except for Hand Innovations vs. Zimmer bending stiffness post fatigue (p = .197). the significant higher load to failure of the titanium plate, makes it indicated for patients with higher functional requirements or at higher risk of trauma in the post-operative period. The CFR-PEEK plate showed material-specific disadvantages, represented by little tolerance to plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  14. Strain-dependent dynamic compressive properties of magnetorheological elastomeric foams

    NASA Astrophysics Data System (ADS)

    Wereley, Norman M.; Perez, Colette; Choi, Young T.

    2018-05-01

    This paper addresses the strain-dependent dynamic compressive properties (i.e., so-called Payne effect) of magnetorheological elastomeric foams (MREFs). Isotropic MREF samples (i.e., no oriented particle chain structures), fabricated in flat square shapes (nominal size of 26.5 mm x 26.5 mm x 9.5 mm) were synthesized by randomly dispersing micron-sized iron oxide particles (Fe3O4) into a liquid silicone foam in the absence of magnetic field. Five different Fe3O4 particle concentrations of 0, 2.5, 5.0, 7.5, and 10 percent by volume fraction (hereinafter denoted as vol%) were used to investigate the effect of particle concentration on the dynamic compressive properties of the MREFs. The MREFs were sandwiched between two multi-pole flexible plate magnets in order to activate the magnetorheological (MR) strengthening effect. Under two different pre-compression conditions (i.e., 35% and 50%), the dynamic compressive stresses of the MREFs with respect to dynamic strain amplitudes (i.e., 1%-10%) were measured by using a servo-hydraulic testing machine. The complex modulus (i.e., storage modulus and loss modulus) and loss factors of the MREFs with respect to dynamic strain amplitudes were presented as performance indices to evaluate their strain-dependent dynamic compressive behavior.

  15. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    PubMed

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p < 0.05 and p > 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation for 2-level DS could be less invasive and result in improvement of clinical symptoms equal to those of 2-level PLIF using traditional PS fixation. The incidence of symptomatic ASD and the rate of bony union were lower in the CBT group than in the PS group, although these differences were not significant.

  16. Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

    NASA Technical Reports Server (NTRS)

    Baily, N. A.

    1974-01-01

    Research data obtained by the low dose electronic radiography system are reported. Data cover: (1) localization and tracking of Ta screws implanted in the inner wall of the right ventrical of the heart, (2) use of cross hairs to outline inner or outer heart wall contours, (3) quantitative measure of anatomical components which are stationary in size or change size dynamically, and (4) study of dynamic quantitative data from roentenologic or fluoroscopic procedures.

  17. Dynamic Compression Promotes the Matrix Synthesis of Nucleus Pulposus Cells Through Up-Regulating N-CDH Expression in a Perfusion Bioreactor Culture.

    PubMed

    Xu, Yichun; Yao, Hui; Li, Pei; Xu, Wenbin; Zhang, Junbin; Lv, Lulu; Teng, Haijun; Guo, Zhiliang; Zhao, Huiqing; Hou, Gang

    2018-01-01

    An adequate matrix production of nucleus pulposus (NP) cells is an important tissue engineering-based strategy to regenerate degenerative discs. Here, we mainly aimed to investigate the effects and mechanism of mechanical compression (i.e., static compression vs. dynamic compression) on the matrix synthesis of three-dimensional (3D) cultured NP cells in vitro. Rat NP cells seeded on small intestinal submucosa (SIS) cryogel scaffolds were cultured in the chambers of a self-developed, mechanically active bioreactor for 10 days. Meanwhile, the NP cells were subjected to compression (static compression or dynamic compression at a 10% scaffold deformation) for 6 hours once per day. Unloaded NP cells were used as controls. The cellular phenotype and matrix biosynthesis of NP cells were investigated by real-time PCR and Western blotting assays. Lentivirus-mediated N-cadherin (N-CDH) knockdown and an inhibitor, LY294002, were used to further investigate the role of N-CDH and the PI3K/Akt pathway in this process. Dynamic compression better maintained the expression of cell-specific markers (keratin-19, FOXF1 and PAX1) and matrix macromolecules (aggrecan and collagen II), as well as N-CDH expression and the activity of the PI3K/Akt pathway, in the 3D-cultured NP cells compared with those expression levels and activity in the cells grown under static compression. Further analysis showed that the N-CDH knockdown significantly down-regulated the expression of NP cell-specific markers and matrix macromolecules and inhibited the activation of the PI3K/Akt pathway under dynamic compression. However, inhibition of the PI3K/Akt pathway had no effects on N-CDH expression but down-regulated the expression of NP cell-specific markers and matrix macromolecules under dynamic compression. Dynamic compression increases the matrix synthesis of 3D-cultured NP cells compared with that of the cells under static compression, and the N-CDH-PI3K/Akt pathway is involved in this regulatory process. This study provides a promising strategy to promote the matrix deposition of tissue-engineered NP tissue in vitro prior to clinical transplantation. © 2018 The Author(s). Published by S. Karger AG, Basel.

  18. Immediate Weightbearing After First Metatarsophalangeal Joint Arthrodesis With Screw and Locking Plate Fixation: A Short-Term Review.

    PubMed

    Abben, Kyle W; Sorensen, Matthew D; Waverly, Brett J

    2018-05-08

    Historically, the postoperative protocol for patients undergoing first metatarsophalangeal joint arthrodesis has included 6 weeks of non-weightbearing, followed by protected weightbearing in a below-the-knee cast boot or postoperative shoe. This prolonged period of non-weightbearing predisposes the patient to disuse atrophy, osteopenia, deep vein thrombosis risk, and, overall, a prolonged time to recovery. The present study reports a retrospective review of a patient cohort that underwent first metatarsophalangeal joint fusion with immediate full weightbearing postoperatively. Thirty consecutive first metatarsophalangeal joint arthrodeses were performed during the study period. Five patients were excluded secondary to insufficient postoperative follow-up data or a lack of adequate radiographic evaluation at regular postoperative intervals. Conical reamers were used for joint preparation. Internal fixation, consisting of a single cannulated interfragmentary compression screw and a dorsal locking plate, was used in all patients. The results showed that patients achieved clinical healing at an average of 5.92 weeks and showed radiographic fusion at an average of 6.83 weeks. The patients in the present study had an overall union rate of 96%. Complications included 1 nonunion, 1 superficial wound infection, 1 wound dehiscence, 1 case of symptomatic hardware, and 2 patients with symptomatic hallux interphalangeal joint arthralgia. The mean visual analog pain score preoperatively was 6.64 (range 4 to 8) and postoperatively was 0.6 (range 0 to 4). In conclusion, we found that immediate full weightbearing after first metatarsophalangeal joint fusion in the context of interfragmentary compression and locked plating techniques is a safe, predictable postoperative protocol that allows for a successful fusion interval and an early return to regular activity. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. [Dynamic analysis of the rigid fixed bridge and related tissue after intrusion of abutment with micro screw implant].

    PubMed

    Zhu, Lin; Xu, Pei-cheng; Lu, Liu-lei

    2013-08-01

    To study the variety of mechanical behavior of fixed bridge after abutments being intruded by micro screw implant and to provide theoretical principles for clinical practice of teeth preparation after intrusion of abutments under dynamic loads. Two-dimensional images of maxilla, teeth and supporting tissues of healthy people were scanned by spiral CT and were synthesized by Mimics10.01, Ansys13.0, etc. The three-dimensional finite element mathematical model of rigid fixed bridge repairing on double end of maxillary molar was developed. Under the condition of 10% simulative abutment alveolar absorption, vertical and oblique dynamic forces were applied in a circle of mastication(0.875 s) to build mathematical model after the abutment had been intruded for 0.5, 1.0, 1.5 and 2.0 mm. Stress variety of prosthesis, teeth, periodontal ligaments and supporting tissues were compared before and after intrusion of abutments. Stress variety of the prosthesis occurred, which had close relationship with the structure of prosthesis and teeth, the areas of periodontal ligaments increased, stress on the whole decreased along with the increase of the length of intrusion. With time accumulating, the stress value in prosthesis, teeth, periodontal ligaments and supporting tissues increased gradually and loads in oblique direction induced peak value stress in a masticatory cycle. Some residual stress left after unloading. By preparing the fixed bridge after abutment intrusion by micro screw implant, the service life of abutment and fixed bridge prosthesis can be reduced. The abutment and its related tissue have time-dependent mechanical behaviors during one mastication. The influence of oblique force on stress was greater than vertical force. There is some residual stress left after one mastication period. With the increase of the intrusion on abutment, residual stress reduced.

  20. [Pedicular dynamic stabilization system. Functional outcomes and implant-related complications for the treatment of degenerative lumbar disc disease with a minimum follow-up of 4 years].

    PubMed

    Segura-Trepichio, M; Ferrández-Sempere, D; López-Prats, F; Segura-Ibáñez, J; Maciá-Soler, L

    2014-01-01

    The Dynesys(®) system is a non-fusion pedicular dynamic stabilization system. The aim of our study is to evaluate the clinical outcomes in patients with degenerative disc disease and/or stenosis, and to measure the prevalence of screw loosening and breakage after 4 years of follow up. All patients who underwent surgery with Dynesys(®) system in 2008 were reviewed. The surgery was performed in cases of low back pain of more than 6 months duration and a positive MRI for degenerative disc disease and/or stenosis. A total of 22 patients (11 females, 11 males) with a mean age of 44.40 ± 11 years were included, 20 patients (91%) underwent Dynesys(®) without any associated decompression maneuver. The evaluation of back and leg pain (0-10mm) showed a mean decrease of 2.4 ± 2.06 mm (P=.0001). The preoperative value of the Oswestry disability index was 52.36 ± 16.56% (severe functional limitation). After surgery, this value was 34.27 ± 17.87% (moderate functional limitation) (P=.001) with a decrease of 18.09 ± 16.03% (P=.001). A total of 4 (18%) patients showed signs of loosening screws. One patient (4.5%) had a screw breakage. Surgery with Dynesys(®) shows favorable long term clinical results, however the range of improvement in our series is lower than those reported in other studies. Comparative studies between Dynesys(®) and decompression need to be performed in order to isolate the benefit of the dynamic stabilization system. Implant-related complications are not uncommon. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  1. Dynamic compressive behavior of Pr-Nd alloy at high strain rates and temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Huanran; Cai Canyuan; Chen Danian

    2012-07-01

    Based on compressive tests, static on 810 material test system and dynamic on the first compressive loading in split Hopkinson pressure bar (SHPB) tests for Pr-Nd alloy cylinder specimens at high strain rates and temperatures, this study determined a J-C type [G. R. Johnson and W. H. Cook, in Proceedings of Seventh International Symposium on Ballistics (The Hague, The Netherlands, 1983), pp. 541-547] compressive constitutive equation of Pr-Nd alloy. It was recorded by a high speed camera that the Pr-Nd alloy cylinder specimens fractured during the first compressive loading in SHPB tests at high strain rates and temperatures. From highmore » speed camera images, the critical strains of the dynamic shearing instability for Pr-Nd alloy in SHPB tests were determined, which were consistent with that estimated by using Batra and Wei's dynamic shearing instability criterion [R. C. Batra and Z. G. Wei, Int. J. Impact Eng. 34, 448 (2007)] and the determined compressive constitutive equation of Pr-Nd alloy. The transmitted and reflected pulses of SHPB tests for Pr-Nd alloy cylinder specimens computed with the determined compressive constitutive equation of Pr-Nd alloy and Batra and Wei's dynamic shearing instability criterion could be consistent with the experimental data. The fractured Pr-Nd alloy cylinder specimens of compressive tests were investigated by using 3D supper depth digital microscope and scanning electron microscope.« less

  2. Electromechanically Actuated Valve for Controlling Flow Rate

    NASA Technical Reports Server (NTRS)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces. The inlet end (the right end as depicted in the figure) of the ball screw would be the main seating valve element: in the fully closed position, it would be pressed against the valve seat, as depicted in the upper part of the figure. A retainer would hold the valve seat in an inlet fitting. In addition, the retainer would be contoured to obtain a specified flow rate as a function of axial position of the ball screw. In the fully closed position, little force would be needed to press the ball screw against the seat because the push bore area upon which the upstream pressure would act would be small. The motor would position and hold the ball screw against the seat, providing the force necessary for sealing. To open the valve to a particular position, the motor would be commanded to rotate to a particular angular position (equivalently, a particular number of revolutions) at a particular rate of rotation within its torque limitations. Once the valve was open, fluid would flow through the inlet fitting and the chamber in the inlet housing, past the seat and its retainer, along the hollow core of the ball screw, and through the outlet housing and outlet fitting. The net force generated from fluid pressure in the open position would be small because the pressure exposed to the push bore areas at the inlet and outlet are nearly equal and the forces generated would be in opposing directions.

  3. [Stress test and clinical application of the minimal-invasive dynamic hip screw].

    PubMed

    Tong, Song-Lin; Chen, Jian-Lie; Lu, Wen-Jie; Pan, Zhi-Jun; Wang, Yi-Jin

    2008-05-01

    To recognize the effect of minimal-invasive dynamic hip screw (MIDHS) on the treatment of intertrochanteric fracture of the hip by biomechanical test and preliminary clinical application. Ten artifical made intertrochanteric fractures of femoral specimen from five cadavers were divided into two groups randomly. The fractures in first group were fixed by MIDHS and other group were fixed by dynamic hip (DHS). Biomechanical characteristics of two different devices were compared with the biomechanical character of load-straining, load-displacing, rigidity and strength of femur by statistic analysis. According to the Harris evaluation, healing effect of intertrochanteric fractures was evaluated clinically on the 15 cases. Straining changes of MIDHS were 14% and 11% less than that of DHS on the tensile side and the pressure side respectively; Sinking and horizontal displacement, were 19% and 22% less than that of DHS respectivly. But external and internal stress intensity,axial and bending rigidity were all higher than that of DHS, they were 12%, 11%, 19% and 37%. Maximal destroyed twisting moment (15%) and average twisting rigidity (15%) were both higher than that of DHS, but twisting angle was 18% less. Under the force, of 1 800 N, the open angle of the fracture on transverse section was 2.28 degrees,while the DHS's was 3.60 degrees . The data above were significant differences statistically (P < 0.01). The average Harris score of the 15 cases with intertrochanteric fractures treated by MIDHS was 91, excellent and good rate was 92.7%, without complications of internal fixation failure,postoperative infection and so on. The design of minimal-invasive dynamic hip screw is reasonable and effective against rotating, shearing and varus stress force of the fracture, and it provides possibility of implanting the internal fixation with minimal incision. So it is an ideal internal fixation device for the treatment of intertrochanteric fractures.

  4. Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw System.

    PubMed

    2016-01-01

    The purpose of this clinical study is to determine whether the rate of fracture healing and fracture union, repaired with a locked device, will be as good as or better than standard nonlocking bicortical fixation in distal femoral fractures. Institutional review board-approved, multicenter prospective randomized controlled trial. Seven level 1 trauma centers across Canada. Fifty-two patients with distal femoral fractures (AO/OTA 33A1 to 33C2) were enrolled in the randomized trial. Twelve AO/OTA 33C3 fractures were excluded from the randomized trial but followed up as a nonrandomized cohort. Patients were treated through a standardized minimally invasive approach. Fractures were randomized 1:1 to treatment with the locked Less Invasive Stabilization System (LISS; Synthes, Paoli, PA) or the dynamic condylar screw (DCS). The nonrandomized cohort was treated at the surgeon's discretion. Primary outcomes were time to radiological union and number of delayed/nonunions at 12 months. Secondary outcomes were postoperative function and complications. Fifty-two patients were randomized including 34 women and 18 men. The mean age was 59 years. Twenty-eight patients were treated with the LISS and 24 with the DCS. There was no statistically significant difference between the LISS and the DCS in terms of the number of fractures healed, time to union, or functional scores. Complications and revisions were more common in the LISS group. There were 7 reoperations in the LISS group and one in the DCS group. Only 52% of the LISS group healed without intervention by 12 months compared with 91% in the DCS group. There was no advantage to the locking plate design in the management of distal femoral fractures in this study. The higher cost of the locking plates, challenges in technique, and lack of superiority have led the authors to discontinue the use of this lateral unicortical locking device in favor of other devices that allow locked or nonlocked bicortical fixation, articular compression, and bridging of the comminuted fracture segments. The cost-effective treatment for a subgroup or periarticular fractures may be a fixed-angle nonlocked device in patients with reasonable bone quality. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  5. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures.

    PubMed

    Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S

    2016-01-01

    When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years) and mean followup period was 52.1 months (range 27-72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.

  6. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system.

    PubMed

    Kaneyama, Shuichi; Sugawara, Taku; Sumi, Masatoshi

    2015-03-15

    Clinical trial for midcervical pedicle screw insertion using a novel patient-specific intraoperative screw guiding device. To evaluate the availability of the "Screw Guide Template" (SGT) system for insertion of midcervical pedicle screws. Despite many efforts for accurate midcervical pedicle screw insertion, there still remain unacceptable rate of screw malpositioning that might cause neurovascular injuries. We developed patient-specific SGT system for safe and accurate intraoperative screw navigation tool and have reported its availability for the screw insertion to C2 vertebra and thoracic spine. Preoperatively, the bone image on computed tomography was analyzed and the trajectories of the screws were designed in 3-dimensional format. Three types of templates were created for each lamina: location template, drill guide template, and screw guide template. During the operations, after engaging the templates directly with the laminae, drilling, tapping, and screwing were performed with each template. We placed 80 midcervical pedicle screws for 20 patients. The accuracy and safety of the screw insertion by SGT system were evaluated using postoperative computed tomographic scan by calculation of screw deviation from the preplanned trajectory and evaluation of screw breach of pedicle wall. All templates fitted the laminae and screw navigation procedures proceeded uneventfully. All screws were inserted accurately with the mean screw deviation from planned trajectory of 0.29 ± 0.31 mm and no neurovascular complication was experienced. We demonstrated that our SGT system could support the precise screw insertion in midcervical pedicle. SGT prescribes the safe screw trajectory in a 3-dimensional manner and the templates fit and lock directly to the target laminae, which prevents screwing error along with the change of spinal alignment during the surgery. These advantages of the SGT system guarantee the high accuracy in screw insertion, which allowed surgeons to insert cervical pedicle screws safely. 3.

  7. Four-corner fusion of the wrist: clinical and radiographic outcome of 31 patients.

    PubMed

    Mavrogenis, Andreas F; Flevas, Dimitrios A; Raptis, Konstantinos; Megaloikonomos, Panayiotis D; Igoumenou, Vasilios G; Antoniadou, Thekla; Dimopoulos, Leonidas; Antonopoulos, Dimitrios; Spyridonos, Sarantis G

    2016-12-01

    Four-corner fusion is a rational surgical option for the management of degenerative conditions of the wrist. Most related studies have compared four-corner fusion with scaphoid excision or proximal row carpectomy, with a variety of reported results. To enhance the literature, we performed this study to evaluate a series of patients with degenerative conditions of the wrist treated with four-corner fusion using 3 surgical techniques and to discuss the clinical and radiographic outcome of the patients. We retrospectively studied 31 patients (24 men, 7 women; mean age, 43 years; 9 heavy manual laborers) who underwent four-corner fusion of their wrists for degenerative conditions from 2005 to 2015. Internal fixation was done using multiple Kirschner wires (14 patients), headless compressive screws (8 patients), or a circular plate (9 patients). Mean follow-up was 4 years (1-11 years). We evaluated the clinical outcome with the Patient-Rated Wrist Evaluation (PRWE) score and fusion with radiographs. All patients experienced improvement of their pain, function, range of motion and grip strength (p < 0.05). Twenty-three patients (74 %) reported no pain, and eight patients reported mild, occasional pain. Twenty-one patients (68 %) were able to do usual and specific activities. Mean wrist motion improved to 70 % and mean grip strength improved to 85 % of opposite wrist. Two heavy manual labor patients requested a job modification because of wrist impairment. Radiographs of the wrist showed fusion of all fused joints in 28 (90.3 %) patients and partial fusion in three patients (9.7 %). No patient with partial fusion required a reoperation for symptomatic nonunion until the period of this study. Three patients experienced complications (10 %). Two patients treated with a circular plate experienced complex regional pain syndrome and painful implant impingement; another patient treated with Kirschner wires and headless compression screws experienced radiolunate arthritis from impingement of the lunate screw to the radius. Four-corner fusion is a reliable limited wrist fusion technique that provides pain relief, grip strength and satisfactory range of motion in patients with degenerative conditions of the wrist. Partial union is more common with Kirschner wire fixation and complications are more common with circular plate fixation.

  8. Lumbar Spinal Stenosis Minimally Invasive Treatment with Bilateral Transpedicular Facet Augmentation System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masala, Salvatore, E-mail: salva.masala@tiscali.it; Tarantino, Umberto; Nano, Giovanni, E-mail: gionano@gmail.com

    Purpose. The purpose of this study was to evaluate the effectiveness of a new pedicle screw-based posterior dynamic stabilization device PDS Percudyn System Trade-Mark-Sign Anchor and Stabilizer (Interventional Spine Inc., Irvine, CA) as alternative minimally invasive treatment for patients with lumbar spine stenosis. Methods. Twenty-four consecutive patients (8 women, 16 men; mean age 61.8 yr) with lumbar spinal stenosis underwent implantation of the minimally invasive pedicle screw-based device for posterior dynamic stabilization. Inclusion criteria were lumbar stenosis without signs of instability, resistant to conservative treatment, and eligible to traditional surgical posterior decompression. Results. Twenty patients (83 %) progressively improved duringmore » the 1-year follow-up. Four (17 %) patients did not show any improvement and opted for surgical posterior decompression. For both responder and nonresponder patients, no device-related complications were reported. Conclusions. Minimally invasive PDS Percudyn System Trade-Mark-Sign has effectively improved the clinical setting of 83 % of highly selected patients treated, delaying the need for traditional surgical therapy.« less

  9. Quasicontinuum analysis of dislocation-coherent twin boundary interaction to provide local rules to discrete dislocation dynamics

    NASA Astrophysics Data System (ADS)

    Tran, H.-S.; Tummala, H.; Duchene, L.; Pardoen, T.; Fivel, M.; Habraken, A. M.

    2017-10-01

    The interaction of a pure screw dislocation with a Coherent Twin Boundary Σ3 in copper was studied using the Quasicontinuum method. Coherent Twin Boundary behaves as a strong barrier to dislocation glide and prohibits slip transmission across the boundary. Dislocation pileup modifies the stress field at its intersection with the Grain Boundary (GB). A methodology to estimate the strength of the barrier for a dislocation to slip across CTB is proposed. A screw dislocation approaching the boundary from one side either propagates into the adjacent twin grain by cutting through the twin boundary or is stopped and increases the dislocation pileup amplitude at the GB. Quantitative estimation of the critical stress for transmission was performed using the virial stress computed by Quasicontinuum method. The transmission mechanism and critical stress are in line with the literature. Such information can be used as input for dislocation dynamic simulations for a better modeling of grain boundaries.

  10. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur - is the Dynamic Hip Screw the Prevailing Gold Standard?

    PubMed

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the 'gold standard' implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve.

  11. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    PubMed

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.

    PubMed

    Tan, Ban Fui; Tan, Keson B; Nicholls, Jack I

    2004-01-01

    Critical bending moment (CBM), the moment at which the external nonaxial load applied overcomes screw joint preload and causes loss of contact between the mating surfaces of the implant screw joint components, was measured with 2 types of implants and 2 types of abutments. Using 4 test groups of 5 implant-abutment pairs, CBM at the implant-abutment screw joint was measured at 25%, 50%, 75%, and 100% of the manufacturer's recommended torque levels. Regular Platform (RP) Nobel Biocare implants (3.75 mm diameter), Wide Platform (WP) Nobel Biocare implants (5.0 mm diameter), CeraOne abutments, and Multiunit abutments were used. Microstrain was measured as loads were applied to the abutment at various distances from the implant-abutment interface. Strain instrumentation logged the strain data dynamically to determine the point of gap opening. All torque applications and strain measurements were repeated 5 times. For the CeraOne-RP group, the mean CBMs were 17.09 Ncm, 35.35 Ncm, 45.63 Ncm, and 62.64 Ncm at 25%, 50%, 75%, and 100% of the recommended torque level, respectively. For the CeraOne-WP group, mean CBMs were 28.29 Ncm, 62.97 Ncm, 92.20 Ncm, and 127.41 Ncm; for the Multiunit-RP group, 16.08 Ncm, 21.55 Ncm, 34.12 Ncm, and 39.46 Ncm; and for the Multiunit-WP group, 15.90 Ncm, 32.86 Ncm, 43.29 Ncm, and 61.55 Ncm at the 4 different torque levels. Two-way analysis of variance (ANOVA) (P < .001) revealed significant effects for the test groups (F = 2738.2) and torque levels (F = 2969.0). The methodology developed in this study allows confirmation of the gap opening of the screw joint for the test groups and determination of CBM at different torque levels. CBM was found to differ among abutment systems, implant diameters, and torque levels. The torque levels recommended by the manufacturer should followed to ensure screw joint integrity.

  13. Surface characteristics of clinically used dental implant screws

    NASA Astrophysics Data System (ADS)

    Han, Myung-Ju; Choe, Han-Cheol; Chung, Chae-Heon

    2005-12-01

    Surface alteration of implant screws after function may be associated with mechanicalffailure. This type of metal fatigue appears to be the most common cause of structural failure. The purpose of this study was to evaluate surface alteration of implant screws after function through an examination of used and unused implant screws via scanning electron microscopy (SEM). In this study, abutment screws (Steri-oss, 3i, USA), gold retaining screws (3i, USA), and titanium retaining screws (3i, USA) were retrieved from patients, New, unused abutment, and retaining screws were prepared for a control group. Each of the old, used screws was retrieved with a screwdriver. The retrieved implant complex of a Steri-oss system was also prepared for this study. SEM investigation and energy dispersive spectroscopy (EDS) analysis of the abutment and retaining screws were then performed, as well as SEM investigation of a cross-sectioned sample of the retrieved implant complex in the case of new, unused implant screws, as-manufactured circumferential grooves were regularly examined and screw threads were sharply maintained. Before ultrasonic cleansing of old, used implant screws, there was a large amount of debris accumulation and corrosion products. After ultrasonic cleansing of old, used implant screws, circumferential grooves were examined were found to be randomly deepened and scratching increased. Also, dull screw fhreads were observed. More surface alterations after function were observed in titanium screws than in gold screws. Furthermore, more surface alteration was observed when the screws were retrieved with a driver than without a driver. These surface alterations after function may result in screw instability. Regular cleansing and exchange of screws is therefore recommended. We also recommend the use of gold screws over titanium screws, and careful manipulation of the driver.

  14. Effect of screw position on load transfer in lumbar pedicle screws: A non-idealized finite element analysis

    PubMed Central

    Newcomb, Anna G. U. S.; Baek, Seungwon; Kelly, Brian P.; Crawford, Neil R.

    2016-01-01

    Angled screw insertion has been advocated to enhance fixation strength during posterior spine fixation. Stresses on a pedicle screw and surrounding vertebral bone with different screw angles were studied by finite element analysis during simulated multidirectional loading. Correlations between screw-specific vertebral geometric parameters and stresses were studied. Angulations in both the sagittal and axial planes affected stresses on the cortical and cancellous bones and the screw. Pedicle screws pointing laterally (vs. straight or medially) in the axial plane during superior screw angulation may be advantageous in terms of reducing the risk of both screw loosening and screw breakage. PMID:27454197

  15. In vivo dynamic compression has less detrimental effect than static compression on newly formed bone of a rat caudal vertebra

    PubMed Central

    Benoit, A.; Mustafy, T.; Londono, I.; Grimard, G.; Aubin, C-E.; Villemure, I.

    2016-01-01

    Fusionless devices are currently designed to treat spinal deformities such as scoliosis by the application of a controlled mechanical loading. Growth modulation by dynamic compression was shown to preserve soft tissues. The objective of this in vivo study was to characterize the effect of static vs. dynamic loading on the bone formed during growth modulation. Controlled compression was applied during 15 days on the 7th caudal vertebra (Cd7) of rats during growth spurt. The load was sustained in the “static” group and sinusoidally oscillating in the “dynamic” group. The effect of surgery and of the device was investigated using control and sham (operated on but no load applied) groups. A high resolution CT-scan of Cd7 was acquired at days 2, 8 and 15 of compression. Growth rates, histomorphometric parameters and mineral density of the newly formed bone were quantified and compared. Static and dynamic loadings significantly reduced the growth rate by 20% compared to the sham group. Dynamic loading preserved newly formed bone histomorphometry and mineral density whereas static loading induced thicker (+31%) and more mineralized (+12%) trabeculae. A significant sham effect was observed. Growth modulation by dynamic compression constitutes a promising way to develop new treatment for skeletal deformities. PMID:27609036

  16. Effects of dynamic range compression on spatial selective auditory attention in normal-hearing listeners.

    PubMed

    Schwartz, Andrew H; Shinn-Cunningham, Barbara G

    2013-04-01

    Many hearing aids introduce compressive gain to accommodate the reduced dynamic range that often accompanies hearing loss. However, natural sounds produce complicated temporal dynamics in hearing aid compression, as gain is driven by whichever source dominates at a given moment. Moreover, independent compression at the two ears can introduce fluctuations in interaural level differences (ILDs) important for spatial perception. While independent compression can interfere with spatial perception of sound, it does not always interfere with localization accuracy or speech identification. Here, normal-hearing listeners reported a target message played simultaneously with two spatially separated masker messages. We measured the amount of spatial separation required between the target and maskers for subjects to perform at threshold in this task. Fast, syllabic compression that was independent at the two ears increased the required spatial separation, but linking the compressors to provide identical gain to both ears (preserving ILDs) restored much of the deficit caused by fast, independent compression. Effects were less clear for slower compression. Percent-correct performance was lower with independent compression, but only for small spatial separations. These results may help explain differences in previous reports of the effect of compression on spatial perception of sound.

  17. Effect of fluid compressibility on journal bearing performance

    NASA Technical Reports Server (NTRS)

    Dimofte, Florin

    1993-01-01

    An analysis was undertaken to determine the effect of fluid film compressibility on the performance of fluid film bearings. A new version of the Reynolds equation was developed, using a polytropic expansion, for both steady-state and dynamic conditions. Polytropic exponents from 1 (isothermal) to 1000 (approaching an incompressible liquid) were evaluated for two bearing numbers, selected from a range of practical interest for cryogenic application, and without cavitation. Bearing loads were insensitive to fluid compressibility for low bearing numbers, as was expected. The effect of compressibility on attitude angle was significant, even when the bearing number was low. A small amount of fluid compressibility was enough to obtain stable running conditions. Incompressible liquid lacked stability at all conditions. Fluid compressibility can be used to control the bearing dynamic coefficients, thereby influencing the dynamic behavior of the rotor-bearing system.

  18. Data compression of discrete sequence: A tree based approach using dynamic programming

    NASA Technical Reports Server (NTRS)

    Shivaram, Gurusrasad; Seetharaman, Guna; Rao, T. R. N.

    1994-01-01

    A dynamic programming based approach for data compression of a ID sequence is presented. The compression of an input sequence of size N to that of a smaller size k is achieved by dividing the input sequence into k subsequences and replacing the subsequences by their respective average values. The partitioning of the input sequence is carried with the intention of reducing the mean squared error in the reconstructed sequence. The complexity involved in finding the partitions which would result in such an optimal compressed sequence is reduced by using the dynamic programming approach, which is presented.

  19. Dynamic XRD, Shock and Static Compression of CaF2

    NASA Astrophysics Data System (ADS)

    Kalita, Patricia; Specht, Paul; Root, Seth; Sinclair, Nicholas; Schuman, Adam; White, Melanie; Cornelius, Andrew; Smith, Jesse; Sinogeikin, Stanislav

    2017-06-01

    The high-pressure behavior of CaF2 is probed with x-ray diffraction (XRD) combined with both dynamic compression, using a two-stage light gas gun, and static compression, using diamond anvil cells. We use XRD to follow the unfolding of a shock-driven, fluorite to cotunnite phase transition, on the timescale of nanoseconds. The dynamic behavior of CaF2 under shock loading is contrasted with that under static compression. This work leverages experimental capabilities at the Advanced Photon Source: dynamic XRD and shock experiments at the Dynamic Compression Sector, as well as XRD and static compression in diamond anvil cell at the High-Pressure Collaborative Access Team. These experiments and cross-platform comparisons, open the door to an unprecedented understanding of equations of state and phase transitions at the microstructural level and at different time scales and will ultimately improve our capability to simulate the behavior of materials at extreme conditions. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  20. Hollow screw-like drill in plasma using an intense Laguerre-Gaussian laser

    NASA Astrophysics Data System (ADS)

    Wang, Wenpeng; Shen, Baifei; Zhang, Xiaomei; Zhang, Lingang; Shi, Yin; Xu, Zhizhan

    2015-02-01

    With the development of ultra-intense laser technology, MeV ions can be obtained from laser-foil interactions in the laboratory. These energetic ion beams can be applied in fast ignition for inertial confinement fusion, medical therapy, and proton imaging. However, these ions are mainly accelerated in the laser propagation direction. Ion acceleration in an azimuthal orientation was scarcely studied. In this research, a doughnut Laguerre-Gaussian (LG) laser is used for the first time to examine laser-plasma interaction in the relativistic intensity regime in three-dimensional particle-in-cell simulations. Studies have shown that a novel rotation of the plasma is produced from the hollow screw-like drill of an mode laser. The angular momentum of particles in the longitudinal direction produced by the LG laser is enhanced compared with that produced by the usual laser pulses, such as linearly and circularly polarized Gaussian pulses. Moreover, the particles (including electrons and ions) can be trapped and uniformly compressed in the dark central minimum of the doughnut LG pulse. The hollow-structured LG laser has potential applications in the generation of x-rays with orbital angular momentum, plasma accelerators, fast ignition for inertial confinement fusion, and pulsars in the astrophysical environment.

  1. Hollow screw-like drill in plasma using an intense Laguerre-Gaussian laser.

    PubMed

    Wang, Wenpeng; Shen, Baifei; Zhang, Xiaomei; Zhang, Lingang; Shi, Yin; Xu, Zhizhan

    2015-02-05

    With the development of ultra-intense laser technology, MeV ions can be obtained from laser-foil interactions in the laboratory. These energetic ion beams can be applied in fast ignition for inertial confinement fusion, medical therapy, and proton imaging. However, these ions are mainly accelerated in the laser propagation direction. Ion acceleration in an azimuthal orientation was scarcely studied. In this research, a doughnut Laguerre-Gaussian (LG) laser is used for the first time to examine laser-plasma interaction in the relativistic intensity regime in three-dimensional particle-in-cell simulations. Studies have shown that a novel rotation of the plasma is produced from the hollow screw-like drill of an mode laser. The angular momentum of particles in the longitudinal direction produced by the LG laser is enhanced compared with that produced by the usual laser pulses, such as linearly and circularly polarized Gaussian pulses. Moreover, the particles (including electrons and ions) can be trapped and uniformly compressed in the dark central minimum of the doughnut LG pulse. The hollow-structured LG laser has potential applications in the generation of x-rays with orbital angular momentum, plasma accelerators, fast ignition for inertial confinement fusion, and pulsars in the astrophysical environment.

  2. Processing research and development of 'green' polymer nanoclay composites containing a polyhydroxybutyrate, vinyl acetates, and modified montmorillonite clay

    NASA Astrophysics Data System (ADS)

    McKirahan, James N., Jr.

    The purpose of this research was to determine the feasibility of direct melt-blending (intercalation) montmorillonite nanoclay to polyhydroxybutyrate along with vinyl acetate, at different weight percentages, to enhance plasticization using typical plastic processing equipment and typical processing methodology. The purpose was to determine and compare the specific mechanical properties of tensile strength and flexural strength developed as a result from this processing. Single screw and twin screw extrusion, Banbury mixer compounding, and compression molding were used to intercalate montmorillonite, and for sample preparation purposes, to test tensile and flexural strength of the resultant polymer clay nanocomposites (PCN). Results indicate Polyhydroxybutyrate and Ethylene vinyl acetate, and weight percentages of 70%, 65% and 60% PHB, and 15%, 20%, and 25% of EVA, respectively, influenced mechanical properties. The resultant materials remained in a mostly amorphous state. The nanoclay, at specific weight percentage of 10%, acted as an antimicrobial and preservative for the materials produced during the research. The intention of the research was to promote knowledge and understanding concerning these materials and processes so technology transfer regarding the use, mechanical properties, manufacture, and process ability of these bio-friendly materials to academia, industry, and society can occur.

  3. Wing-augmentation reduces femoral head cutting out of dynamic hip screw.

    PubMed

    Chen, Chih-Yu; Huang, Shu-Wei; Sun, Jui-Sheng; Lin, Shin-Yiing; Yu, Chih-Sheng; Pan, Hsu-Pin; Lin, Ping-Hung; Hsieh, Fan-Chun; Tsuang, Yang-Hwei; Lin, Feng-Huei; Yang, Rong-Sen; Cheng, Cheng-Kung

    2017-06-01

    The dynamic hip screw (DHS) is commonly used in the treatment of femoral intertrochanteric fracture with high satisfactory results. However, post-operative failure does occur and result in poor prognosis. The most common failure is femoral head varus collapse, followed by lag screw cut-out through the femoral head. In this study, a novel-designed DHS with two supplemental horizontal blades was used to improve the fixation stability. In this study, nine convention DHS and 9 Orthopaedic Device Research Center (ODRC) DHSs were tested in this study. Each implant was fixed into cellular polyurethane rigid foam as a surrogate of osteoporotic femoral head. Under biaxial rocking motion, all constructs were loaded to failure point (12mm axial displacement) or up to 20,000 cycles of 1.45kN peak magnitude were achieved, whichever occurred first. The migration kinematics was continuously monitored and recorded. The final tip-to-apex distance, rotational angle and varus deformation were also recorded. The results showed that the ODRC DHS sustained significantly more loading cycles and exhibited less axial migration in comparison to the conventional DHS. The ODRC DHS showed a significantly smaller bending strain and larger torsional strain compared to the conventional DHS. The changes in tip-to-apex distance (TAD), post-study varus angle, post-study rotational angle of the ODRC DHS were all significantly less than that of the conventional DHS (p < 0.05). We concluded that the ODRC DHS augmented with two horizontal wings would increase the bone-implant interface contact surface, dissipate the load to the screw itself, which improves the migration resistance and increases the anti-rotational implant effect. In conclusion, the proposed ODRC DHS demonstrated significantly better migration resistance and anti-rotational effect in comparison to the conventional DHS construct. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.

    PubMed

    Al-Munajjed, Amir A; Hammer, Joachim; Mayr, Edgar; Nerlich, Michael; Lenich, Andreas

    2008-01-01

    Proximal femur fractures are of main concern for elderly and especially osteoporotic patients. Despite advanced implant modifications and surgical techniques, serious mechanical complication rates between 4-18% are found in conventional osteosyntheses of proximal femur fractures. Clinical complications such as the rotation of the femoral head and the cut-out phenomenon of the fracture fixation bolt are often diagnosed during post-operative treatments. Therefore, efforts in new intramedulary techniques focus on the load bearing characteristics of the implant by developing new geometries to improve the implant-tissue interface. The objective of this investigation was to analyse the osteosynthesis/femur head interaction of two commonly used osteosyntheses, one with a helical blade and the other one with a screw design under different loading conditions. For the comparative investigation the helical blade of the Proximal Femur Nail Antirotation was investigated versus the screw system of the Dynamic Hip Screw. After implantation in a femoral head the loads for rotational overwinding of the implants were analysed. Pull-out forces with suppressed rotation were investigated with analysis of the influence of the previous overwinding. All investigations were performed on human femoral heads taken of patients with average age of 70.3+/-11.8. The bone mineral densities of the human specimens were detected by QCT-scans (average BMD: 338.9+/- 61.3$\\frac[\\mathit[mg

  5. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    PubMed

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  6. Characteristics of pedicle screw loading. Effect of sagittal insertion angle on intrapedicular bending moments.

    PubMed

    Youssef, J A; McKinley, T O; Yerby, S A; McLain, R F

    1999-06-01

    A bending analysis of pedicle screws inserted into vertebral body analogues. Intravertebral and intrapedicular pedicle screw bending moments were studied as a function of sagittal insertion angle. To determine how the pedicle screw bending moment is affected by changes in the insertion angle. There is a significant incidence of failure when pedicle screws are used to instrument unstable spinal segments. Extrinsic factors that affect screw bending failure have been poorly characterized. Previous work has demonstrated that intrapedicular pedicle screw bending moments are significantly affected by the sagittal location and depth of pedicle screw placement. Pedicle screw transducers were inserted in analogue vertebrae at one of three orientations: 7 degrees cephalad (toward the superior endplate), 7 degrees caudal (toward the inferior endplate), or parallel to the superior endplate (control). An axial load was applied to the superior endplate of the vertebra, and screw bending moments were recorded directly from the transducers. Screws angled 7 degrees cephalad developed significantly greater mean intrapedicular bending moments compared with screws inserted caudal or control screws. There was no significant difference in bending moments realized within the vertebral body for the three screw positions. Angulating pedicle screws toward the superior endplate increased bending moments within the pedicle. If attention to optimal screw insertion technique can reduce bending moments and potential for screw failure without increasing morbidity, surgical risk, or operative time, then proper insertion technique takes on new importance.

  7. A Comparison of Removal Rates of Headless Screws Versus Headed Screws in Calcaneal Osteotomy.

    PubMed

    Kunzler, Daniel; Shazadeh Safavi, Pejma; Jupiter, Daniel; Panchbhavi, Vinod K

    2017-11-01

    Calcaneal osteotomy has been used to successfully treat both valgus and varus hindfoot deformities. Pain associated with implanted hardware may lead to further surgical intervention for hardware removal. Headless screws have been used to reduce postoperative hardware-associated pain and accompanying hardware removal, but data proving their effectiveness in this regard is lacking. The purpose of this study is to compare the rates of removal of headed and headless screws utilized in calcaneal osteotomy. We conducted a retrospective chart review of 74 patients who underwent calcaneal osteotomy between January 2010 and December 2014. The cohort was divided into 2 groups by fixation method: a headed screw and a headless screw group. Bivariate associations between infection or hardware removal, and screw type, screw head width, gender, smoking status, alcohol, hypertension, diabetes, hyperlipidemia, age, and body mass index were assessed using t-tests and Fisher's exact/χ 2 tests for continuous and discrete variables, respectively. Headed screws were removed more frequently than headless screws (P < .0001): 15 of 30 (50%) feet that received headed screws and 4 of 44 (9%) of feet that received headless screws underwent subsequent revision for screw removal. In all cases, screws were removed because of pain. The calcaneal union rate was 100% in both cohorts. The rate of screw removal in calcaneal osteotomies is significantly lower in patients who receive headless screws than in those receiving headed screws. Level IV.

  8. Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.

    PubMed

    Boukebous, Baptiste; Guillon, Pascal; Vandenbussche, Eric; Rousseau, Marc Antoine

    2018-04-27

    Screw-plates disassembly incidence after pertrochanteric fracture (PF) amounts to 1 and 16% among the elderly population. The main occurrence is early cervical screw cut-out. The population at highest risk of disassembly remains difficult to identify. The correlation between femoral offset loss and disassembly occurrence has never been surveyed. A radiological prognosis score for screw plate disassembly was defined to reflect trochanteric impaction (TI); it was based on a femoral offset ratio. Our single-centre retrospective case-control study surveyed patients suffering from Dynamic Hip Screw (DHS, Synthes ® ) disassembly following osteosynthesis of non-pathological osteoporotic PF between 2004 and 2014. All cases were categorised by age and gender and paired to three patients in the control group. The primary endpoint was TI measurement, corresponding to offset loss on the operated hip compared to healthy hip offset and expressed as a percentage. The measurement was done on an immediate postoperative X-ray. The secondary endpoints were tip apex distance (TAD) measurement, Ender and AO classifications, as well as postoperative weight-bearing prescription. Twenty-three cases and 69 controls were surveyed. The case group's average age was 87; 70% of the cases were women. The main disassembly occurrence delay was after 27 days. Average TI was 26% within the patients global group and 12% within the control group (p < 10 -5 ). Over a 21% impaction percentage, disassembly occurrence represents a greater risk: OR = 21.95% CI [5.4-104.3], p < 10 -5 . Ender 3 type fractures were the most frequent indication for surgery within the case group. Average TAD was 20 mm within the case group, and 17 mm within the control group (p = 0.03). The weight-bearing prescription rate was 52% within the control group and 21% within the case group (p = 0.014). 14.5% of the control group had a TI > 21%. Using the offset ratio tool, TI measurement was associated with a greater risk of DHS disassembly when it was higher than 21%. The exclusive use of a DHS device does not seem optimal for a TI > 21%. Weight-bearing may be prescribed for all the patients with a TI < 21%, provided good implant positioning is secured.

  9. Solute softening and defect generation during prismatic slip in magnesium alloys

    NASA Astrophysics Data System (ADS)

    Yi, Peng; Cammarata, Robert C.; Falk, Michael L.

    2017-12-01

    Temperature and solute effects on prismatic slip of 〈a〉 dislocations in Mg are studied using molecular dynamics simulation. Prismatic slip is controlled by the low mobility screw dislocation. The screw dislocation glides on the prismatic plane through alternating cross-slip between the basal plane and the prismatic plane. In doing so, it exhibits a locking-unlocking mechanism at low temperatures and a more continuous wavy propagation at high temperatures. The dislocation dissociates into partials on the basal plane and the constriction formation of the partials is identified to be the rate-limiting process for unlocking. In addition, the diffusion of partials on the basal plane enables the formation of jogs and superjogs for prismatic slip, which lead to the generation of vacancies and dislocation loops. Solute softening in Mg alloys was observed in the presence of both Al and Y solute. The softening in prismatic slip is found to be due to solute pinning on the basal plane, instead of the relative energy change of the screw dislocation on the basal and prismatic planes, as has been hypothesized.

  10. Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

    PubMed

    Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2015-08-01

    The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

  11. Surgical Management of Ipsilateral Fracture of the Femur and Tibia in Adults (the Floating Knee): Postoperative Clinical, Radiological, and Functional Outcomes

    PubMed Central

    2011-01-01

    Background This study evaluated the outcomes of surgical management of ipsilateral femoral and tibial fractures in adults. Methods Fifteen patients (13 men, 2 women; mean age, 34.8 years; range, 18 to 65 years) were enrolled in this study. The fractures types were classified according to the classification by Fraser et al. as follows: type I (5), type IIa (3), IIb (4), IIc (3). Femur fractures were treated using locked intramedullary nails, plate-screws, or dynamic condylar screws, and tibia fractures were treated with an external fixator (in open fractures), or plate-screws, and locked intramedullary nailing. The mean follow-up duration was 2.2 years (range, 1.3 to 4 years). Results The extent of bony union according to the Karlstrom criteria was as follows: excellent, 8; good, 4; acceptable, 2; poor, 1. Conclusions The associated injuries and type of fracture (open, intra-articular, comminution) are prognostic factors in a floating knee. The best management of the associated injuries for good final outcome involves intramedullary nailing of both the fractures and postoperative rehabilitation. PMID:21629474

  12. Experimental investigation of dynamic compression and spallation of Cerium at pressures up to 6 GPa

    NASA Astrophysics Data System (ADS)

    Zubareva, A. N.; Kolesnikov, S. A.; Utkin, A. V.

    2014-05-01

    In this study the experiments on one-dimensional dynamic compression of Cerium (Ce) samples to pressures of 0.5 to 6 GPa using various types of explosively driven generators were conducted. VISAR laser velocimeter was used to obtain Ce free surface velocity profiles. The isentropic compression wave was registered for γ-phase of Ce at pressures lower than 0.76 GPa that corresponds to γ-α phase transition pressure in Ce. Shock rarefaction waves were also registered in several experiments. Both observations were the result of the anomalous compressibility of γ-phase of Ce. On the basis of our experimental results the compression isentrope of Ce γ-phase was constructed. Its comparison with volumetric compression curves allowed to estimate the magnitude of shear stress at dynamic compression conditions for Ce. Spall strength measurements were also conducted for several samples. They showed a strong dependence of the spall strength of Ce on the strain rate.

  13. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    PubMed Central

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety and in vivo performance of products derived from xenogeneic bone should be the focus of further investigations. PMID:20433761

  14. Parallel image compression

    NASA Technical Reports Server (NTRS)

    Reif, John H.

    1987-01-01

    A parallel compression algorithm for the 16,384 processor MPP machine was developed. The serial version of the algorithm can be viewed as a combination of on-line dynamic lossless test compression techniques (which employ simple learning strategies) and vector quantization. These concepts are described. How these concepts are combined to form a new strategy for performing dynamic on-line lossy compression is discussed. Finally, the implementation of this algorithm in a massively parallel fashion on the MPP is discussed.

  15. Biomechanical Comparison of Superior Versus Anterior Plate Position for Fixation of Distal Clavicular Fractures: A New Model.

    PubMed

    Wilkerson, James; Paryavi, Ebrahim; Kim, Hyunchul; Murthi, Anand; Pensy, Raymond A

    2017-01-01

    Although most clavicular fractures are amenable to nonoperative management, metadiaphyseal fractures are considerably more complex, with rates of suboptimal healing as high as 75% when treated nonoperatively. The poor results are ascribed to the deforming forces on the distal clavicle from the surrounding muscles and the weight of the arm. It recently has been noted that some operative fixations of these fractures are also failing when a standard superiorly placed plate is used. We hypothesized that anterior plating, when compared with superior plating, improves the strength and durability of the construct by redirecting the axis of the major deforming force across rather than in line with the screws of the construct. Six pairs of fresh-frozen human cadaveric clavicles with the scapula attached by the coracoclavicular ligaments were osteotomized just medial to the ligaments and plated with a standard 3.5-mm limited-contact dynamic compression plate. Specimens were potted and mounted on a materials testing system machine, preserving the anatomic relationship of the clavicle and scapula. They were then loaded through the coracoclavicular ligaments to mimic the weight of the arm pulling inferiorly. Each specimen was loaded with 375 N at 1 Hz for 2000 cycles. Sequential loading was then applied at 25-N intervals until failure. Statistical analysis was performed using a Wilcoxon signed-rank test. The superiorly plated specimens failed after fewer cycles and with lower force than the anteriorly plated specimens. The median number of cycles to failure was 2082 for anterior plated specimens and 50 for superiorly plated (P = 0.028). The median load to failure was 587.5 N in the anterior group and 375 N in the superior group (P = 0.035). The median stiffness was 46.13 N/mm for anterior and 40.45 N/mm for superior (P = 0.375) plates. Anteriorly plated distal third clavicular fractures have superior strength and durability compared with fractures plated superiorly when using a physician-contoured, 3.5-mm, limited-contact, dynamic compression plate in this cadaver model.

  16. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  17. Breaking of rod-shaped model material during compression

    NASA Astrophysics Data System (ADS)

    Lukas, Kulaviak; Vera, Penkavova; Marek, Ruzicka; Miroslav, Puncochar; Petr, Zamostny; Zdenek, Grof; Frantisek, Stepanek; Marek, Schongut; Jaromir, Havlica

    2017-06-01

    The breakage of a model anisometric dry granular material caused by uniaxial compression was studied. The bed of uniform rod-like pasta particles (8 mm long, aspect ratio 1:8) was compressed (Gamlen Tablet Press) and their size distribution was measured after each run (Dynamic Image Analysing). The compression dynamics was recorded and the effect of several parameters was tested (rate of compression, volume of granular bed, pressure magnitude and mode of application). Besides the experiments, numerical modelling of the compressed breakable material was performed as well, employing the DEM approach (Discrete Element Method). The comparison between the data and the model looks promising.

  18. A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

    PubMed

    Kenzig, Allison R; Butler, James R; Priddy, Lauren B; Lacy, Kristen R; Elder, Steven H

    2017-07-13

    Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model.

  19. Ship Dynamics in the Surf Zone Model Testing

    DTIC Science & Technology

    2008-07-01

    was implemented for ease of transportation and ease of assembly. Each module was 10 feet square consisting of oriented strand board ( OSB ) plywood with...frame, constructed of 2 inch by 4 inch by 10 feet pieces of wood, was measured, cut, laid, and screwed together for each module. Pieces of OSB

  20. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    PubMed

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  1. Intramedullary nails with two lag screws.

    PubMed

    Brown, C J; Wang, C J; Yettram, A L; Procter, P

    2004-06-01

    To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cut-out to occur. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws. Comparative analyses demonstrate that two lag screws may be advantageous in patients whose cancellous bone quality is good and who impose large loads on the lag screw/nail interface. However, the use of two screws might pre-dispose to failure by cut-out of the lag screws. The addition of a slotted hole for the upper lag screw appears to do nothing significant to reduce the risk of such a failure. Copyright 2004 Elsevier Ltd.

  2. Dynamic compressive strength of epoxy composites

    NASA Astrophysics Data System (ADS)

    Plastinin, A. V.; Sil'vestrov, V. V.

    1996-11-01

    The strength of laminated and unidirectionally reinforced composite materials was investigated in conditions of dynamic uniaxial compression with a strain rate of 50-1000 sec-1 using the split Hopkinson pressure bar method. It was shown that in conditions of dynamic compression, glass/epoxy, aramid/epoxy, and carbon/epoxy composites exhibit elastic-brittle behavior with anisotropy of the strength and elastic properties. The effect of the strain rate on the strength characteristics of fiberglass-reinforced plastics was demonstrated.

  3. Integrating dynamic and distributed compressive sensing techniques to enhance image quality of the compressive line sensing system for unmanned aerial vehicles application

    NASA Astrophysics Data System (ADS)

    Ouyang, Bing; Hou, Weilin; Caimi, Frank M.; Dalgleish, Fraser R.; Vuorenkoski, Anni K.; Gong, Cuiling

    2017-07-01

    The compressive line sensing imaging system adopts distributed compressive sensing (CS) to acquire data and reconstruct images. Dynamic CS uses Bayesian inference to capture the correlated nature of the adjacent lines. An image reconstruction technique that incorporates dynamic CS in the distributed CS framework was developed to improve the quality of reconstructed images. The effectiveness of the technique was validated using experimental data acquired in an underwater imaging test facility. Results that demonstrate contrast and resolution improvements will be presented. The improved efficiency is desirable for unmanned aerial vehicles conducting long-duration missions.

  4. Are We Underestimating the Significance of Pedicle Screw Misplacement?

    PubMed

    Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly

    2016-05-01

    A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and reevaluation of postoperative low-dose CT imaging. 3.

  5. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    PubMed

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  6. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2015-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  7. Ball Screw Actuator Including a Compliant Ball Screw Stop

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  8. Ultrasound melted polymer sleeve for improved screw anchorage in trabecular bone--A novel screw augmentation technique.

    PubMed

    Schmoelz, W; Mayr, R; Schlottig, F; Ivanovic, N; Hörmann, R; Goldhahn, J

    2016-03-01

    Screw anchorage in osteoporotic bone is still limited and makes treatment of osteoporotic fractures challenging for surgeons. Conventional screws fail in poor bone quality due to loosening at the screw-bone interface. A new technology should help to improve this interface. In a novel constant amelioration process technique, a polymer sleeve is melted by ultrasound in the predrilled screw hole prior to screw insertion. The purpose of this study was to investigate in vitro the effect of the constant amelioration process platform technology on primary screw anchorage. Fresh frozen femoral heads (n=6) and vertebrae (n=6) were used to measure the maximum screw insertion torque of reference and constant amelioration process augmented screws. Specimens were cut in cranio-caudal direction, and the screws (reference and constant amelioration process) were implanted in predrilled holes in the trabecular structure on both sides of the cross section. This allowed the pairwise comparison of insertion torque for constant amelioration process and reference screws (femoral heads n=18, vertebrae n=12). Prior to screw insertion, a micro-CT scan was made to ensure comparable bone quality at the screw placement location. The mean insertion torque for the constant amelioration process augmented screws in both, the femoral heads (44.2 Ncm, SD 14.7) and the vertebral bodies (13.5 Ncm, SD 6.3) was significantly higher than for the reference screws of the femoral heads (31.7 Ncm, SD 9.6, p<0.001) and the vertebral bodies (7.1 Ncm, SD 4.5, p<0.001). The interconnection of the melted polymer sleeve with the surrounding trabecular bone in the constant amelioration process technique resulted in a higher screw insertion torque and can improve screw anchorage in osteoporotic trabecular bone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Orbiting dynamic compression laboratory

    NASA Technical Reports Server (NTRS)

    Ahrens, T. J.; Vreeland, T., Jr.; Kasiraj, P.; Frisch, B.

    1984-01-01

    In order to examine the feasibility of carrying out dynamic compression experiments on a space station, the possibility of using explosive gun launchers is studied. The question of whether powders of a refractory metal (molybdenum) and a metallic glass could be well considered by dynamic compression is examined. In both cases extremely good bonds are obtained between grains of metal and metallic glass at 180 and 80 kb, respectively. When the oxide surface is reduced and the dynamic consolidation is carried out in vacuum, in the case of molybdenum, tensile tests of the recovered samples demonstrated beneficial ultimate tensile strengths.

  10. Failure analysis of broken pedicle screws on spinal instrumentation.

    PubMed

    Chen, Chen-Sheng; Chen, Wen-Jer; Cheng, Cheng-Kung; Jao, Shyh-Hua Eric; Chueh, Shan-Chang; Wang, Chang-Chih

    2005-07-01

    Revised spinal surgery is needed when there is a broken pedicle screw in the patient. This study investigated the pedicle screw breakage by conducting retrieval analyses of broken pedicle screws from 16 patients clinically and by performing stress analyses in the posterolateral fusion computationally using finite element (FE) models. Fracture surface of screws was studied by scanning electron microscope (SEM). The FE model of the posterolateral fusion with the screw showed that screws on the caudal side had larger axial stress than those on the cephalic side, supporting the clinical findings that 75% of the patients had the screw breakage on the caudal side. SEM fractography showed that all broken screws exhibited beach marks or striations on the fractured surface, indicating fatigue failure. Screws of patients with spinal fracture showed fatigue striations and final ductile fracture around the edge. Among the 16 patients who had broken pedicle screws 69% of them achieved bone union in the bone graft, showing that bone union in the bone graft did not warrant the prevention of screw breakage.

  11. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    PubMed

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended than that in S1. Experimental study Level III. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  12. The Use of Sphere Indentation Experiments to Characterize Ceramic Damage Models

    DTIC Science & Technology

    2011-09-01

    state having two equal eigenvalues. For TXC, the axial stress (single eigenvalue) is more compressive than the lateral stresses (dual eigenvalues). For...parameters. These dynamic experiments supplement traditional characterization experiments such as tension, triaxial compression , Brazilian, and...These dynamic experiments supplement traditional characterization experiments such as tension, triaxial compression , Brazilian, and plate impact, which

  13. Adult's Degenerative Scoliosis: Midterm Results of Dynamic Stabilization without Fusion in Elderly Patients—Is It Effective?

    PubMed Central

    Di Silvestre, Mario; Lolli, Francesco; Greggi, Tiziana; Vommaro, Francesco; Baioni, Andrea

    2013-01-01

    Study Design. A retrospective study. Purpose. Posterolateral fusion with pedicle screw instrumentation used for degenerative lumbar scoliosis can lead to several complications. In elderly patients without sagittal imbalance, dynamic stabilization could represent an option to avoid these adverse events. Methods. 57 patients treated by dynamic stabilization without fusion were included. All patients had degenerative lumbar de novo scoliosis (average Cobb angle 17.2°), without sagittal imbalance, associated in 52 cases (91%) with vertebral canal stenosis and in 24 (42%) with degenerative spondylolisthesis. Nineteen patients (33%) had previously undergone lumbar spinal surgery. Results. At an average followup of 77 months, clinical results improved with statistical significance. Scoliosis Cobb angle was 17.2° (range, 12° to 38°) before surgery and 11.3° (range, 4° to 26°) at last follow-up. In the patients with associated spondylolisthesis, anterior vertebral translation was 19.5% (range, 12% to 27%) before surgery, 16.7% (range, 0% to 25%) after surgery, and 17.5% (range, 0% to 27%) at followup. Complications incidence was low (14%), and few patients required revision surgery (4%). Conclusions. In elderly patients with mild degenerative lumbar scoliosis without sagittal imbalance, pedicle screw-based dynamic stabilization is an effective option, with low complications incidence, granting curve stabilization during time and satisfying clinical results. PMID:23781342

  14. Collaborative Research Program on Advanced Metals and Ceramics for Armor and Anti-Armor Applications Dynamic Behavior of Non-Crystalline and Crystalline Metallic Systems

    DTIC Science & Technology

    2006-09-01

    compression, including real-time cinematography of failure under dynamic compression, was evaluated. The results (figure 10) clearly show that the failure... art of simulations of dynamic failure and damage mechanisms. An explicit dynamic parallel code has been developed to track damage mechanisms in the

  15. The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: A finite element study.

    PubMed

    Weng, Pei-Wei; Chen, Chia-Hsien; Luo, Chu-An; Sun, Jui-Sheng; Tsuang, Yang-Hwei; Cheng, Cheng-Kung; Lin, Shang-Chih

    2017-04-01

    Several plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.e., cortical) screw through the proximal combi-hole, to deform the plate and pull the distal tibia toward the plate. This process potentially induces plate springback and creates an elastic preload on the osteotomized tibia, especially at the lateral hinge of the distracted wedge. Using the finite-element method, this study aims to investigate the contoured effect of lag-screw application on the biomechanical behavior of the tibia-plate construct. Two tibial profiles (normal and more concave), three distraction angles (6°, 9°, and 12°), and three knee loads (intraoperative: contouring plate; postoperative: weight and nonweight bearing) are systematically varied in this study. The wedge instability and fracture risk at the lateral hinge are chosen as the comparison indices. The results show the necessity of preoperative planning for a precontoured procedure, rather than elastic deformation using a lag screw. Within the intraoperative period, a more concave tibial profile and/or reduced distraction angle (i.e., 6° or 9°) necessitate a higher compressive load to elastically deform the plate, thereby deteriorating the lateral-hinge fracture risk. A precontoured plate is recommended in the case that the proximal tibia is highly concave and the distraction angle is insufficient to stretch the tibial profile. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. A proposed radiographic classification scheme for congenital thoracic vertebral malformations in brachycephalic "screw-tailed" dog breeds.

    PubMed

    Gutierrez-Quintana, Rodrigo; Guevar, Julien; Stalin, Catherine; Faller, Kiterie; Yeamans, Carmen; Penderis, Jacques

    2014-01-01

    Congenital vertebral malformations are common in brachycephalic "screw-tailed" dog breeds such as French bulldogs, English bulldogs, Boston terriers, and pugs. The aim of this retrospective study was to determine whether a radiographic classification scheme developed for use in humans would be feasible for use in these dog breeds. Inclusion criteria were hospital admission between September 2009 and April 2013, neurologic examination findings available, diagnostic quality lateral and ventro-dorsal digital radiographs of the thoracic vertebral column, and at least one congenital vertebral malformation. Radiographs were retrieved and interpreted by two observers who were unaware of neurologic status. Vertebral malformations were classified based on a classification scheme modified from a previous human study and a consensus of both observers. Twenty-eight dogs met inclusion criteria (12 with neurologic deficits, 16 with no neurologic deficits). Congenital vertebral malformations affected 85/362 (23.5%) of thoracic vertebrae. Vertebral body formation defects were the most common (butterfly vertebrae 6.6%, ventral wedge-shaped vertebrae 5.5%, dorsal hemivertebrae 0.8%, and dorso-lateral hemivertebrae 0.5%). No lateral hemivertebrae or lateral wedge-shaped vertebrae were identified. The T7 vertebra was the most commonly affected (11/28 dogs), followed by T8 (8/28 dogs) and T12 (8/28 dogs). The number and type of vertebral malformations differed between groups (P = 0.01). Based on MRI, dorsal, and dorso-lateral hemivertebrae were the cause of spinal cord compression in 5/12 (41.6%) of dogs with neurologic deficits. Findings indicated that a modified human radiographic classification system of vertebral malformations is feasible for use in future studies of brachycephalic "screw-tailed" dogs. © 2014 American College of Veterinary Radiology.

  17. Fractographic analysis of 2.0-mm plates with a screw locking system in simulated fractures of the mandibular body.

    PubMed

    de Medeiros, Raquel Correia; Lauria de Moura, Andrezza; Rodrigues, Danillo Costa; Menezes Mendes, Marcelo Breno; Sawazaki, Renato; Fernandes Moreira, Roger William

    2014-06-01

    The purpose of the present study was to analyze the fractured plates from 2 brands of 2.0-mm locking fixation systems submitted to axial linear load testing. Four aluminum hemimandibles with linear sectioning to simulate a mandibular body fracture were used as a substrate and fixed with 2 fixation techniques from 2 national brands: Tóride and Traumec. The techniques were as follows: one 4-hole plate, with four 6-mm screws in the tension zone, and one 4-hole plate, with four 10-mm screws in the compression zone; and one 4-hole plate, with four 6-mm holes in the neutral zone. The hemimandibles were submitted to vertical linear load tests using an Instron 4411 mechanical test machine. The system was submitted to the test until complete failure had occurred. Next, a topographic analysis of the surface of the plates was performed using a stereomicroscope and an electronic scanning microscope. The samples were evaluated using different magnifications, and images were obtained. The surface of the fracture analyzed in scanning electron microscopy demonstrated a ductile-type fracture, usually found in the traction test bodies of ductile materials, such as titanium. No evidence of failure was observed in any fracture surface from a change in the structure or composition of the material. The plates were fractured by a ductile rupture mechanism, as expected, suggesting that the manufacturing of the national brand name plates used in the present study has been under adequate quality control, with no structural changes produced by the manufacturing process that could compromise their function. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Biomechanical comparison of orthogonal versus parallel double plating systems in intraarticular distal humerus fractures.

    PubMed

    Atalar, Ata C; Tunalı, Onur; Erşen, Ali; Kapıcıoğlu, Mehmet; Sağlam, Yavuz; Demirhan, Mehmet S

    2017-01-01

    In intraarticular distal humerus fractures, internal fixation with double plates is the gold standard treatment. However the optimal plate configuration is not clear in the literature. The aim of this study was to compare the biomechanical stability of the parallel and the orthogonal anatomical locking plating systems in intraarticular distal humerus fractures in artificial humerus models. Intraarticular distal humerus fracture (AO13-C2) with 5 mm metaphyseal defect was created in sixteen artificial humeral models. Models were fixed with either orthogonal or parallel plating systems with locking screws (Acumed elbow plating systems). Both systems were tested for their stiffness with loads in axial compression, varus, valgus, anterior and posterior bending. Then plastic deformation after cyclic loading in posterior bending and load to failure in posterior bending were tested. The failure mechanisms of all the samples were observed. Stiffness values in every direction were not significantly different among the orthogonal and the parallel plating groups. There was no statistical difference between the two groups in plastic deformation values (0.31 mm-0.29 mm) and load to failure tests in posterior bending (372.4 N-379.7 N). In the orthogonal plating system most of the failures occurred due to the proximal shaft fracture, whereas in the parallel plating system failure occurred due to the shift of the most distal screw in proximal fragment. Our study showed that both plating systems had similar biomechanical stabilities when anatomic plates with distal locking screws were used in intraarticular distal humerus fractures in artificial humerus models. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  19. Avulsion Fracture of the Calcaneus Treated With a Soft Anchor Bridge and Lag Screw Technique: A Report of Two Cases.

    PubMed

    Yoshida, Kazushige; Kasama, Kentaro; Akahane, Tsutomu

    2016-01-01

    The displaced extra-articular avulsion fracture of the calcaneus has been classified as a Böhler type 1c calcaneal fracture, and most cases will require surgical repair. In the present report, we describe 2 patients in whom we performed the soft anchor bridge technique using single loaded suture anchors with lag screws for the repair of Böhler type 1c avulsion fractures of the calcaneus. In one of these patients, clinically relevant osteoporosis complicated the injury. In both cases, bone union was achieved, and by 1.5 months after surgery satisfactory recovery was observed. To our knowledge, the soft anchor bridge technique was first used for the treatment of rotator cuff tears, and the greatest merit of this technique is the ability to generate vertical compression force to the pulled out rotator cuff through the use of knotting sutures. In recent years, the soft anchor bridge technique using 4 suture anchors has also been used for fractures of the greater tuberosity of the humerus, an injury that poses operative difficulties similar to those encountered with an avulsion fracture of the calcaneus owing to the traction force of the rotator cuff and relative weakness of adjacent bone. The outcomes of our patients suggest that the soft anchor bridge technique combined with adjunct lag screws is useful in the fixation of avulsion fractures of the calcaneus. In addition, the result in the elderly patient indicates the possibility of using this technique for patients with osteoporosis. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Study of factors influencing the mechanical properties of polyurethane foams under dynamic compression

    NASA Astrophysics Data System (ADS)

    Linul, E.; Marsavina, L.; Voiconi, T.; Sadowski, T.

    2013-07-01

    Effect of density, loading rate, material orientation and temperature on dynamic compression behavior of rigid polyurethane foams are investigated in this paper. These parameters have a very important role, taking into account that foams are used as packing materials or dampers which require high energy impact absorption. The experimental study was carried out on closed-cell rigid polyurethane (PUR) foam specimens of different densities (100, 160 respectively 300 kg/m3), having a cubic shape. The specimens were subjected to uniaxial dynamic compression with loading rate in range of 1.37-3.25 m/s, using four different temperatures (20, 60, 90, 110°C) and two loading planes (direction (3) - rise direction and direction (2) - in plane). Experimental results show that Young's modulus, yield stress and plateau stress values increases with increasing density. One of the most significant effects of mechanical properties in dynamic compression of rigid PUR foams is the density, but also the loading speed, material orientation and temperature influences the behavior in compression

  1. Quasi One-Dimensional Unsteady Modeling of External Compression Supersonic Inlets

    NASA Technical Reports Server (NTRS)

    Kopasakis, George; Connolly, Joseph W.; Kratz, Jonathan

    2012-01-01

    The AeroServoElasticity task under the NASA Supersonics Project is developing dynamic models of the propulsion system and the vehicle in order to conduct research for integrated vehicle dynamic performance. As part of this effort, a nonlinear quasi 1-dimensional model of an axisymmetric external compression supersonic inlet is being developed. The model utilizes compressible flow computational fluid dynamics to model the internal inlet segment as well as the external inlet portion between the cowl lip and normal shock, and compressible flow relations with flow propagation delay to model the oblique shocks upstream of the normal shock. The external compression portion between the cowl-lip and the normal shock is also modeled with leaking fluxes crossing the sonic boundary, with a moving CFD domain at the normal shock boundary. This model has been verified in steady state against tunnel inlet test data and it s a first attempt towards developing a more comprehensive model for inlet dynamics.

  2. Dynamical complexity of short and noisy time series. Compression-Complexity vs. Shannon entropy

    NASA Astrophysics Data System (ADS)

    Nagaraj, Nithin; Balasubramanian, Karthi

    2017-07-01

    Shannon entropy has been extensively used for characterizing complexity of time series arising from chaotic dynamical systems and stochastic processes such as Markov chains. However, for short and noisy time series, Shannon entropy performs poorly. Complexity measures which are based on lossless compression algorithms are a good substitute in such scenarios. We evaluate the performance of two such Compression-Complexity Measures namely Lempel-Ziv complexity (LZ) and Effort-To-Compress (ETC) on short time series from chaotic dynamical systems in the presence of noise. Both LZ and ETC outperform Shannon entropy (H) in accurately characterizing the dynamical complexity of such systems. For very short binary sequences (which arise in neuroscience applications), ETC has higher number of distinct complexity values than LZ and H, thus enabling a finer resolution. For two-state ergodic Markov chains, we empirically show that ETC converges to a steady state value faster than LZ. Compression-Complexity measures are promising for applications which involve short and noisy time series.

  3. 100J Pulsed Laser Shock Driver for Dynamic Compression Research

    NASA Astrophysics Data System (ADS)

    Wang, X.; Sethian, J.; Bromage, J.; Fochs, S.; Broege, D.; Zuegel, J.; Roides, R.; Cuffney, R.; Brent, G.; Zweiback, J.; Currier, Z.; D'Amico, K.; Hawreliak, J.; Zhang, J.; Rigg, P. A.; Gupta, Y. M.

    2017-06-01

    Logos Technologies and the Laboratory for Laser Energetics (LLE, University of Rochester) - in partnership with Washington State University - have designed, built and deployed a one of a kind 100J pulsed UV (351 nm) laser system to perform real-time, x-ray diffraction and imaging experiments in laser-driven compression experiments at the Dynamic Compression Sector (DCS) at the Advanced Photon Source, Argonne National Laboratory. The laser complements the other dynamic compression drivers at DCS. The laser system features beam smoothing for 2-d spatially uniform loading of samples and four, highly reproducible, temporal profiles (total pulse duration: 5-15 ns) to accommodate a wide variety of scientific needs. Other pulse shapes can be achieved as the experimental needs evolve. Timing of the laser pulse is highly precise (<200 ps) to allow accurate synchronization of the x-rays with the dynamic compression event. Details of the laser system, its operating parameters, and representative results will be presented. Work supported by DOE/NNSA.

  4. Pullout strength of monocortical and bicortical screws in metaphyseal and diaphyseal regions of the canine humerus.

    PubMed

    Vaughn, Denty Paul; Syrcle, Jason Alan; Ball, John E; Elder, Steven H; Gambino, Jennifer Michele; Griffin, Russell L; McLaughlin, Ronald M

    2016-11-23

    Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contraindicated. Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT). The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI). A bicortical, short monocortical, or 50% transcortical 3.5 mm screw was implanted in each ROI and axial pullout testing was performed. Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest. Short monocortical metaphyseal screws were weaker than those placed in other regions. The 50% transcortical screws were stronger than the short monocortical screws in the condyle. A linear relationship between screw length and pullout strength was observed. Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT. Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle. When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.

  5. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    PubMed

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p < 0.01). Comparing only the screw orientation, the screws oriented at 23 degrees cephalad had a significantly higher failure force than their respective counterparts at 0 degrees (p < 0.01). Conclusions Standard pedicle screw fixation is often inadequate in the osteoporotic spine, but this study suggests tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  6. Scapula fracture incidence in reverse total shoulder arthroplasty using screws above or below metaglene central cage: clinical and biomechanical outcomes.

    PubMed

    Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A

    2017-06-01

    Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    PubMed

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future interference screw designs to improve the performance of implants. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.

    PubMed

    Arshad, Mahnaz; Mahgoli, Hosseinali; Payaminia, Leila

    To evaluate the effect of repeated screw joint closing and opening cycles and cyclic loading on abutment screw removal torque and screw thread morphology using scanning electron microscopy (SEM). Three groups (n = 10 in each group) of implant-abutment-abutment screw assemblies were created. There were also 10 extra abutment screws as new screws in group 3. The abutment screws were tightened to 12 Ncm with an electronic torque meter; then they were removed and removal torque values were recorded. This sequence was repeated 5 times for group 1 and 15 times for groups 2 and 3. The same screws in groups 1 and 2 and the new screws in group 3 were then tightened to 12 Ncm; this was also followed by screw tightening to 30 Ncm and retightening to 30 Ncm 15 minutes later. Removal torque measurements were performed after screws were subjected to cyclic loading (0.5 × 10⁶ cycles; 1 Hz; 75 N). Moreover, the surface topography of one screw from each group before and after cyclic loading was evaluated with SEM and compared with an unused screw. All groups exhibited reduced removal torque values in comparison to insertion torque in each cycle. However, there was a steady trend of torque loss in each group. A comparison of the last cycle of the groups before loading showed significantly greater torque loss value in the 15th cycle of groups 2 and 3 compared with the fifth cycle of group 1 (P < .05). Nonetheless, torque loss values after loading were not shown to be significantly different from each other. Using a new screw could not significantly increase the value of removal torque. It was concluded that restricting the amount of screw tightening is more important than replacing the screw with a new one when an abutment is definitively placed.

  9. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    PubMed Central

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  10. Tibiotalocalcaneal arthrodesis with a compressive retrograde intramedullary nail: a report of 34 consecutive patients.

    PubMed

    Niinimäki, Tuukka Timo; Klemola, Tero-Matti; Leppilahti, Juhana Ilmari

    2007-04-01

    Tibiotalocalcaneal arthrodesis is a treatment modality for severe arthrosis and malalignment of the hindfoot. Complications, such as delayed union and nonunion, are well-known risks of the procedure. Arthrodesis can be done with a plate, screws, an external fixator, or an intramedullary nail. Compression with an intramedullary nail was the focus of this report. Thirty-four consecutive patients (23 men and 11 women) with an average age range of 57 (range 25-77) years had tibiotalocalcaneal arthrodesis using retrograde intramedullary compression nail fixation. Mean followup was 24 (range 6 to 43) months. One patient died of an unrelated cause, but 30 (91%) of the remaining 33 patients answered the questionnaire. Bony consolidation was achieved in 26 (76%) patients, the mean time to fusion being 16 weeks. Five patients (15%) had complications and seven (20%) had repeat surgery. Of the 30 patients who responded to the questionnaire, three patients (10%) evaluated the overall result subjectively as being of no benefit and 27 (90%) as improved. The visual analog scale (VAS) score for preoperative pain was 66 at rest and 83 when walking, and the mean postoperative scores were 19 and 32, respectively (p<0.001). Tibiotalocalcaneal arthrodesis with a compressive retrograde intramedullary nail is an effective and safe procedure for patients with severe malalignment or arthrosis of the hindfoot. It is essentially a salvage procedure, and most patients benefit from it, but excellent results are rare.

  11. Thoracic Vertebral Hemangioma with Spinal Cord Compression: Multidisciplinary Surgical Treatment and Follow-up of Six Patients.

    PubMed

    Zhang, Hui-Lin; Hu, Yong-Cheng; Aryal, Rajendra; He, Xin; Lun, Deng-Xing; Zhao, Li-Ming

    2016-11-01

    To provide useful insights of multidisciplinary surgical treatment for vertebral hemangioma with spinal cord compression. From 2009 to 2014, data on six patients who were diagnosed with cord compression vertebral hemangioma were reviewed and analyzed retrospectively. There were five women and one man with a mean age of 48.6 years (range, 26-68 years). All the patients were treated by multidisciplinary approach, including use of gelfoam, pedicle screw instrumentation, vertebroplasty, and decompression laminectomy. Neurological status and Frankel grades were documented, CT scan and MRI were performed after surgery. The follow-up period ranged from 8 to 54 months. Mean blood loss was around 367 mL, and the mean surgical time was 2.30 h. All patients had uneventful intraoperative and postoperative courses and reported symptomatic and neurological relief to varying degrees, at an average follow-up period of 23 months. Bone cement distribution was disseminated homogeneously over the affected vertebra and no leakage was observed. All the patients had a complete restoration to Frankel grade E. The postoperative and follow-up imaging showed that the implant was in perfect position, and no recurrence occurred in all patients. The vertebral hemangioma with cord compression is a challenge to surgeons for therapeutic improvement, and an active involvement of several disciplines as well as performance of multidisciplinary surgical treatment can be crucial in achieving favorable results. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  12. Effect of injection parameters on mechanical and physical properties of super ultra-thin wall propylene packaging by Taguchi method

    NASA Astrophysics Data System (ADS)

    Ginghtong, Thatchanok; Nakpathomkun, Natthapon; Pechyen, Chiravoot

    2018-06-01

    The parameters of the plastic injection molding process have been investigated for the manufacture of a 64 oz. ultra-thin polypropylene bucket. The 3 main parameters, such as injection speed, melting temperature, holding pressure, were investigated to study their effect on the physical appearance and compressive strength. The orthogonal array of Taguchi's L9 (33) was used to carry out the experimental plan. The physical properties were measured and the compressive strength was determined using linear regression analysis. The differential scanning calorimeter (DSC) was used to analyze the crystalline structure of the product. The optimization results show that the proposed approach can help engineers identify optimal process parameters and achieve competitive advantages of energy consumption and product quality. In addition, the injection molding of the product includes 24 mm of shot stroke, 1.47 mm position transfer, 268 rpm screw speed, injection speed 100 mm/s, 172 ton clamping force, 800 kgf holding pressure, 0.9 s holding time and 1.4 s cooling time, make the products in the shape and proportion of the product satisfactory. The parameters of influence are injection speed 71.07%, melting temperature 23.31% and holding pressure 5.62%, respectively. The compressive strength of the product was able to withstand a pressure of up to 839 N before the product became plastic. The low melting temperature was caused by the superior crystalline structure of the super-ultra-thin wall product which leads to a lower compressive strength.

  13. A comparison of preload values in gold and titanium dental implant retaining screws.

    PubMed

    Doolabh, R; Dullabh, H D; Sykes, L M

    2014-08-01

    This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for the patient and the clinician. This study investigated changes in preload generation after repeated torque applications to gold and titanium screws. The test set-up consisted of an implant body, a cylindrical transmucosa abutment, and the test samples of gold and of titanium retaining screws. The implant bodies were anchored using a load cell, and the transmucosal abutments were attached using either gold or titanium retaining screws. A torque gauge was used to apply torque of 20Ncm, 32Ncm, and 40Ncm to the retaining screws. The preloads generated in each screw type were compared at each torque setting, and after repeated tightening episodes. In addition, the effect of applying torque beyond the manufacturers' recommendations was also examined. Gold retaining screws were found to achieve consistently higher preload values than titanium retaining screws. Preload values were not significantly different from the first to the tenth torque cycle. Titanium screws showed more consistent preload values, albeit lower than those of the gold screws. However due to possible galling of the internal thread of the implant body by titanium screws, gold screws remain the retaining screw of choice. Based on the findings of this study, gold retaining screws generate better preload than titanium. Torque beyond the manufacturers' recommendations resulted in a more stable implant complex. However, further investigations, with torque applications repeated until screw breakage, are needed to advise on ideal maintenance protocols.

  14. Influence of Prosthetic Screw Material on Joint Stability in Passive and Non-Passive Implant-Supported Dentures

    PubMed Central

    Spazzin, Aloísio Oro; Henriques, Guilherme Elias Pessanha; de Arruda Nóbilo, Mauro Antônio; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Mesquita, Marcelo Ferraz

    2009-01-01

    Objectives: This study evaluated the influence of prosthetic screw material on joint stability in implantsupported dentures at two levels of fit. Methods: Ten mandibular implant-supported dentures were fabricated. Twenty cast models were fabricated using these dentures. Four groups (n=10) were tested, according to the vertical fit of the dentures [passive and non-passive] and prosthetic screw materials [titanium (Ti) or gold (Au) alloy]. The one-screw test was performed to quantify the vertical misfits using an optic microscope. The loosening torque for the prosthetic screws was measured 24 hours after the tightening torque (10 Ncm) using a digital torque meter. Data were analyzed by two-way ANOVA and Tukey’s test (α=0.05). Results: Overall, dentures with passive fit and Ti screws resulted in significantly higher loosening torque of the prosthetic screws (p<0.05). No significant interaction was found between fit level and screw material (p=0.199). The prosthetic screw material and fit of implant-supported dentures have an influence on screw joint stability. Ti screws presented higher joint stability than Au screws and minimum of misfit should be found clinically to improve the mechanical behavior of the screw joint. PMID:20148135

  15. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation.

    PubMed

    Sugawara, Taku; Higashiyama, Naoki; Kaneyama, Shuichi; Sumi, Masatoshi

    2017-03-15

    Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm. The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. 3.

  16. Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study.

    PubMed

    Wang, Joon Ho; Lee, Eun Su; Lee, Byung Hoon

    2017-09-16

    Tibial aperture fixation with a bioabsorbable interference screw is a popular fixation method in anterior cruciate ligament reconstruction (ACLR). An interference screw containing β-tricalcium phosphate (β-TCP) to improve bony integration and biocompatibility was recently introduced. This study aims to compare the clinical outcomes and radiological results of tunnel enlargement effect between the 2 bioabsorbable fixative devices of pure poly-L-lactic acid (PLLA) interference screws and β-TCP-containing screws, for tibial interference fixation in ACLR using hamstring autografts. Eighty consecutive patients who had undergone double-bundle ACLR between 2011 to 2012 were prospectively reviewed and randomly divided into two groups based on the type of tibial interference screw: 28 were assigned to the pure PLLA screw group (Group A), while the other 29 were assigned to the β-TCP-containing screw fixation group (Group B). Clinical evaluations and radiological analyses were conducted in both groups with a minimum 2- year follow-up. There was no significant difference in subjective or objective clinical outcome between the 2 groups. In radiological analyses, the use of a β-TCP-containing screw reduced tunnel widening in the portion of the tunnel with screw engagement compared to the pure PLLA screw, while the use of a β-TCP-containing screw resulted in greater tunnel enlargement in the proximal portion of the tunnel without screw engagement than use of a pure PLLA screw. Use of a β-TCP-containing interference screw in tibial aperture fixation reduced tunnel enlargement in the vicinity of the screw, whereas greater enlargement occurred proximal to the screw end relative to use of a pure PLLA interference screw. These paradoxical enlargements in use of β-TCP containing screws suggest that for reducing tunnel enlargement, the length of the interference screw should be as fit as possible with tunnel length in terms of using soft grafts. II, Prospectively comparative study. Retrospectively registered with ClinicalTrials.gov. (NCT02754674) , Date of trial registration: February 10, 2016.

  17. Impact of constrained dual-screw anchorage on holding strength and the resistance to cyclic loading in anterior spinal deformity surgery: a comparative biomechanical study.

    PubMed

    Koller, Heiko; Fierlbeck, Johann; Auffarth, Alexander; Niederberger, Alfred; Stephan, Daniel; Hitzl, Wolfgang; Augat, Peter; Zenner, Juliane; Blocher, Martina; Blocher, Martina; Resch, Herbert; Mayer, Michael

    2014-03-15

    Biomechanical in vitro laboratory study. To compare the biomechanical performance of 3 fixation concepts used for anterior instrumented scoliosis correction and fusion (AISF). AISF is an ideal estimate for selective fusion in adolescent idiopathic scoliosis. Correction is mediated using rods and screws anchored in the vertebral bodies. Application of large correction forces can promote early weakening of the implant-vertebra interfaces, with potential postoperative loss of correction, implant dislodgment, and nonunion. Therefore, improvement of screw-rod anchorage characteristics with AISF is valuable. A total of 111 thoracolumbar vertebrae harvested from 7 human spines completed a testing protocol. Age of specimens was 62.9 ± 8.2 years. Vertebrae were potted in polymethylmethacrylate and instrumented using 3 different devices with identical screw length and unicortical fixation: single constrained screw fixation (SC fixation), nonconstrained dual-screw fixation (DNS fixation), and constrained dual-screw fixation (DC fixation) resembling a novel implant type. Mechanical testing of each implant-vertebra unit using cyclic loading and pullout tests were performed after stress tests were applied mimicking surgical maneuvers during AISF. Test order was as follows: (1) preload test 1 simulating screw-rod locking and cantilever forces; (2) preload test 2 simulating compression/distraction maneuver; (3) cyclic loading tests with implant-vertebra unit subjected to stepwise increased cyclic loading (maximum: 200 N) protocol with 1000 cycles at 2 Hz, tests were aborted if displacement greater than 2 mm occurred before reaching 1000 cycles; and (4) coaxial pullout tests at a pullout rate of 5 mm/min. With each test, the mode of failure, that is, shear versus fracture, was noted as well as the ultimate load to failure (N), number of implant-vertebra units surpassing 1000 cycles, and number of cycles and related loads applied. Thirty-three percent of vertebrae surpassed 1000 cycles, 38% in the SC group, 19% in the DNS group, and 43% in the DC group. The difference between the DC group and the DNS group yielded significance (P = 0.04). For vertebrae not surpassing 1000 cycles, the number of cycles at implant displacement greater than 2 mm in the SC group was 648.7 ± 280.2 cycles, in the DNS group was 478.8 ± 219.0 cycles, and in the DC group was 699.5 ± 150.6 cycles. Differences between the SC group and the DNS group were significant (P = 0.008) as between the DC group and the DNS group (P = 0.0009). Load to failure in the SC group was 444.3 ± 302 N, in the DNS group was 527.7 ± 273 N, and in the DC group was 664.4 ± 371.5 N. The DC group outperformed the other constructs. The difference between the SC group and the DNS group failed significance (P = 0.25), whereas there was a significant difference between the SC group and the DC group (P = 0.003). The DC group showed a strong trend toward increased load to failure compared with the DNS group but without significance (P = 0.067). Surpassing 1000 cycles had a significant impact on the maximum load to failure in the SC group (P = 0.0001) and in the DNS group (P = 0.01) but not in the DC group (P = 0.2), which had the highest number of vertebrae surpassing 1000 cycles. Constrained dual-screw fixation characteristics in modern AISF implants can improve resistance to cyclic loading and pullout forces. DC constructs bear the potential to reduce the mechanical shortcomings of AISF.

  18. Comparison of effectiveness between cork-screw and peg-screw electrodes for transcranial motor evoked potential monitoring using the finite element method.

    PubMed

    Tomio, Ryosuke; Akiyama, Takenori; Ohira, Takayuki; Yoshida, Kazunari

    2016-01-01

    Intraoperative monitoring of motor evoked potentials by transcranial electric stimulation is popular in neurosurgery for monitoring motor function preservation. Some authors have reported that the peg-screw electrodes screwed into the skull can more effectively conduct current to the brain compared to subdermal cork-screw electrodes screwed into the skin. The aim of this study was to investigate the influence of electrode design on transcranial motor evoked potential monitoring. We estimated differences in effectiveness between the cork-screw electrode, peg-screw electrode, and cortical electrode to produce electric fields in the brain. We used the finite element method to visualize electric fields in the brain generated by transcranial electric stimulation using realistic three-dimensional head models developed from T1-weighted images. Surfaces from five layers of the head were separated as accurately as possible. We created the "cork-screws model," "1 peg-screw model," "peg-screws model," and "cortical electrode model". Electric fields in the brain radially diffused from the brain surface at a maximum just below the electrodes in coronal sections. The coronal sections and surface views of the brain showed higher electric field distributions under the peg-screw compared to the cork-screw. An extremely high electric field was observed under cortical electrodes. Our main finding was that the intensity of electric fields in the brain are higher in the peg-screw model than the cork-screw model.

  19. Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

    PubMed

    Sasso, Rick C; Best, Natalie M; Potts, Eric A

    2005-01-01

    Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

  20. The Effects of Hearing Aid Compression Parameters on the Short-Term Dynamic Range of Continuous Speech

    ERIC Educational Resources Information Center

    Henning, Rebecca L. Warner; Bentler, Ruth A.

    2008-01-01

    Purpose: The purpose of this study was to evaluate and quantitatively model the independent and interactive effects of compression ratio, number of compression channels, and release time on the dynamic range of continuous speech. Method: A CD of the Rainbow Passage (J. E. Bernthal & N. W. Bankson, 1993) was used. The hearing aid was a…

  1. Compressive strain induced dynamical stability of monolayer 1T-MX2 (M  =  Mo, W; X  =  S, Se)

    NASA Astrophysics Data System (ADS)

    Li, Xiaoyong; Wu, Musheng; Xu, Bo; Liu, Ruifan; Ouyang, Chuying

    2017-11-01

    The lattice dynamical properties of 1T-MX2 (M  =  Mo, W; X  =  S, Se) under different strains were studied by using density functional perturbation theory method. Our results show that all MX2 with 1T phase in our calculations are dynamical instable under zero strain or tensile strain as obvious imaginary frequencies (soft modes) exist. When 3% biaxial compressive strains are applied, the imaginary frequencies remain except that the absolute values of maximum imaginary frequency decrease. With the increase of compressive strain to be 6%, 1T-MoS2, 1T-MoSe2, 1T-WS2 become stable, whereas 1T-WSe2 has small imaginary frequencies. When biaxial compressive strain reaches 9%, all 1T-MX2 are dynamical stable without imaginary frequencies in the phonon dispersion curves. Energy band structures show that all 1T-MX2 are metallic, regardless of zero strain or compressive strain. Therefore, compressive strain could be a practical approach to enhance the stability of 1T-MX2 while maintaining the metallic property.

  2. Preventing distal pullout of posterior spine instrumentation in thoracic hyperkyphosis: a biomechanical analysis.

    PubMed

    Sun, Edward; Alkalay, Ron; Vader, David; Snyder, Brian D

    2009-06-01

    An in vitro biomechanical study. Compare the mechanical behavior of 5 different constructs used to terminate dual-rod posterior spinal instrumentation in resisting forward flexion moment. Failure of the distal fixation construct can be a significant problem for patients undergoing surgical treatment for thoracic hyperkyphosis. We hypothesize that augmenting distal pedicle screws with infralaminar hooks or sublaminar cables significantly increases the strength and stiffness of these constructs. Thirty-seven thoracolumbar (T12 to L2) calf spines were implanted with 5 configurations of distal constructs: (1) infralaminar hooks, (2) sublaminar cables, (3) pedicle screws, (4) pedicle screws+infralaminar hooks, and (5) pedicle screws+sublaminar cables. Progressive bending moment was applied to each construct until failure. The mode of failure was noted and the construct's stiffness and failure load determined from the load-displacement curves. Bone density and vertebral dimensions were equivalent among the groups (F=0.1 to 0.9, P>0.05). One-way analysis of covariance (adjusted for differences in density and vertebral dimension) demonstrated that all of the screw-constructs (screw, screw+hook, and screw+cable) exhibited significantly higher stiffness and ultimate failure loads compared with either sublaminar hook or cable alone (P<0.05). The screw+hook constructs (109+/-11 Nm/mm) were significantly stiffer than either screws alone (88+/-17 Nm/mm) or screw+cable (98+/-13 Nm/mm) constructs, P<0.05. Screw+cable construct exhibited significantly higher failure load (1336+/-328 N) compared with screw constructs (1102+/-256 N, P<0.05), whereas not statistically different from the screw+hook construct (1220+/-75 N). The cable and hook constructs failed by laminar fracture, screw construct failed in uniaxial shear (pullout), whereas the screws+(hooks or wires) failed by fracture of caudal vertebral body. Posterior dual rod constructs fixed distally using pedicle screws were stiffer and stronger in resisting forward flexion compared with cables or hooks alone. Augmenting these screws with either infralaminar hooks or sublaminar cables provided additional resistance to failure.

  3. Ultra-Low Power Dynamic Knob in Adaptive Compressed Sensing Towards Biosignal Dynamics.

    PubMed

    Wang, Aosen; Lin, Feng; Jin, Zhanpeng; Xu, Wenyao

    2016-06-01

    Compressed sensing (CS) is an emerging sampling paradigm in data acquisition. Its integrated analog-to-information structure can perform simultaneous data sensing and compression with low-complexity hardware. To date, most of the existing CS implementations have a fixed architectural setup, which lacks flexibility and adaptivity for efficient dynamic data sensing. In this paper, we propose a dynamic knob (DK) design to effectively reconfigure the CS architecture by recognizing the biosignals. Specifically, the dynamic knob design is a template-based structure that comprises a supervised learning module and a look-up table module. We model the DK performance in a closed analytic form and optimize the design via a dynamic programming formulation. We present the design on a 130 nm process, with a 0.058 mm (2) fingerprint and a 187.88 nJ/event energy-consumption. Furthermore, we benchmark the design performance using a publicly available dataset. Given the energy constraint in wireless sensing, the adaptive CS architecture can consistently improve the signal reconstruction quality by more than 70%, compared with the traditional CS. The experimental results indicate that the ultra-low power dynamic knob can provide an effective adaptivity and improve the signal quality in compressed sensing towards biosignal dynamics.

  4. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion.

    PubMed

    Tsuji, Matthew; Crookshank, Meghan; Olsen, Michael; Schemitsch, Emil H; Zdero, Rad

    2013-06-01

    Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental over-tightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/ stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2N/mm (cortical screws) and 13.4N/mm (cancellous screws) in sawbone blocks and 20.9N/mm (cortical screws) and 6.1N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4N/mm (cortical screws) and 16.8N/mm (cancellous screws) in sawbone blocks and 29.3N/mm (cortical screws) and 8.3N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the effect of sawbone density or human bone sBMD on stopping and stripping torque. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. A CFD study of Screw Compressor Motor Cooling Analysis

    NASA Astrophysics Data System (ADS)

    Branch, S.

    2017-08-01

    Screw compressors use electric motors to drive the male screw rotor. They are cooled by the suction refrigerant vapor that flows around the motor. The thermal conditions of the motor can dramatically influence the performance and reliability of the compressor. The more optimized this flow path is, the better the motor performance. For that reason it is important to understand the flow characteristics around the motor and the motor temperatures. Computational fluid dynamics (CFD) can be used to provide a detailed analysis of the refrigerant’s flow behavior and motor temperatures to identify the undesirable hot spots in the motor. CFD analysis can be used further to optimize the flow path and determine the reduction of hot spots and cooling effect. This study compares the CFD solutions of a motor cooling model to a motor installed with thermocouples measured in the lab. The compressor considered for this study is an R134a screw compressor. The CFD simulation of the motor consists of a detailed breakdown of the stator and rotor components. Orthotropic thermal conductivity material properties are used to represent the simplified motor geometry. In addition, the analysis includes the motor casings of the compressor to draw heat away from the motor by conduction. The study will look at different operating conditions and motor speeds. Finally, the CFD study will investigate the predicted motor temperature change by varying the vapor mass flow rates and motor speed. Recommendations for CFD modeling of such intricate heat transfer phenomenon have thus been proposed.

  6. Dislocation dynamics simulations of interactions between gliding dislocations and radiation induced prismatic loops in zirconium

    NASA Astrophysics Data System (ADS)

    Drouet, Julie; Dupuy, Laurent; Onimus, Fabien; Mompiou, Frédéric; Perusin, Simon; Ambard, Antoine

    2014-06-01

    The mechanical behavior of Pressurized Water Reactor fuel cladding tubes made of zirconium alloys is strongly affected by neutron irradiation due to the high density of radiation induced dislocation loops. In order to investigate the interaction mechanisms between gliding dislocations and loops in zirconium, a new nodal dislocation dynamics code, adapted to Hexagonal Close Packed metals, has been used. Various configurations have been systematically computed considering different glide planes, basal or prismatic, and different characters, edge or screw, for gliding dislocations with -type Burgers vectors. Simulations show various interaction mechanisms such as (i) absorption of a loop on an edge dislocation leading to the formation of a double super-jog, (ii) creation of a helical turn, on a screw dislocation, that acts as a strong pinning point or (iii) sweeping of a loop by a gliding dislocation. It is shown that the clearing of loops is more favorable when the dislocation glides in the basal plane than in the prismatic plane explaining the easy dislocation channeling in the basal plane observed after neutron irradiation by transmission electron microscopy.

  7. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur – is the Dynamic Hip Screw the Prevailing Gold Standard?

    PubMed Central

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the ‘gold standard’ implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve. PMID:29290858

  8. Electrical wiring box with structure for fast device mounting

    DOEpatents

    Johnston, Earl S.

    1991-01-08

    An electrical wiring box of molded insulating material is provided with bosses having screw holes for receiving a mounting screw that include two colinear portions of which a first portion proximate the front surface has an internal configuration, such as molded threads, that engage the mounting screw while permitting the mounting screw to be manually inserted therethrough without turning because of flexibility built into the boss structure. A second portion of the screw hole is of greater restriction for securely engaging the screw such as by self tapping. The flexibility of the boss is provided by a first center slot that extends from the screw hole to the boss exterior over a length substantially equal to the first portion of the screw hole. Second and third slots are located respectively on each side of the screw hole and provide projections respectively between the first and second slots and the first and third slots that flex to allow easy screw insertion through the first portion of the screw hole.

  9. Development of structural schemes of parallel structure manipulators using screw calculus

    NASA Astrophysics Data System (ADS)

    Rashoyan, G. V.; Shalyukhin, K. A.; Gaponenko, EV

    2018-03-01

    The paper considers the approach to the structural analysis and synthesis of parallel structure robots based on the mathematical apparatus of groups of screws and on a concept of reciprocity of screws. The results are depicted of synthesis of parallel structure robots with different numbers of degrees of freedom, corresponding to the different groups of screws. Power screws are applied with this aim, based on the principle of static-kinematic analogy; the power screws are similar to the orts of axes of not driven kinematic pairs of a corresponding connecting chain. Accordingly, kinematic screws of the outlet chain of a robot are simultaneously determined which are reciprocal to power screws of kinematic sub-chains. Solution of certain synthesis problems is illustrated with practical applications. Closed groups of screws can have eight types. The three-membered groups of screws are of greatest significance, as well as four-membered screw groups [1] and six-membered screw groups. Three-membered screw groups correspond to progressively guiding mechanisms, to spherical mechanisms, and to planar mechanisms. The four-membered group corresponds to the motion of the SCARA robot. The six-membered group includes all possible motions. From the works of A.P. Kotelnikov, F.M. Dimentberg, it is known that closed fifth-order screw groups do not exist. The article presents examples of the mechanisms corresponding to the given groups.

  10. SEM and fractography analysis of screw thread loosening in dental implants.

    PubMed

    Scarano, A; Quaranta, M; Traini, T; Piattelli, M; Piattelli, A

    2007-01-01

    Biological and technical failures of implants have already been reported. Mechanical factors are certainly of importance in implant failures, even if their exact nature has not yet been established. The abutment screw fracture or loosening represents a rare, but quite unpleasant failure. The aim of the present research is an analysis and structural examination of screw thread or abutment loosening compared with screw threads or abutment without loosening. The loosening of screw threads was compared to screw thread without loosening of three different implant systems; Branemark (Nobel Biocare, Gothenburg, Sweden), T.B.R. implant systems (Benax, Ancona, Italy) and Restore (Lifecore Biomedical, Chaska, Minnesota, USA). In this study broken screws were excluded. A total of 16 screw thread loosenings were observed (Group I) (4 Branemark, 4 T.B.R and 5 Restore), 10 screw threads without loosening were removed (Group II), and 6 screw threads as received by the manufacturer (unused) (Group III) were used as control (2 Branemark, 2 T.B.R and 2 Restore). The loosened abutment screws were retrieved and analyzed under SEM. Many alterations and deformations were present in concavities and convexities of screw threads in group I. No macroscopic alterations or deformations were observed in groups II and III. A statistical difference of the presence of microcracks were observed between screw threads with an abutment loosening and screw threads without an abutment loosening.

  11. [Biomaterials in bone repair].

    PubMed

    Puska, Mervi; Aho, Allan J; Vallittu, Pekka K

    2013-01-01

    In orthopedics, traumatology, and craniofacial surgery, biomaterials should meet the clinical demands of bone that include shape, size and anatomical location of the defect, as well as the physiological load-bearing stresses. Biomaterials are metals, ceramics, plastics or materials of biological origin. In the treatment of large defects, metallic endoprostheses or bone grafts are employed, whereas ceramics in the case of small defects. Plastics are employed on the artificial joint surfaces, in the treatment of vertebral compression fractures, and as biodegradable screws and plates. Porosity, bioactivity, and identical biomechanics to bone are fundamental for achieving a durable, well-bonded, interface between biomaterial and bone. In the case of severe bone treatments, biomaterials should also imply an option to add biologically active substances.

  12. Accuracy of pedicle screw insertion by AIRO® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion.

    PubMed

    Rajasekaran, S; Bhushan, Manindra; Aiyer, Siddharth; Kanna, Rishi; Shetty, Ajoy Prasad

    2018-01-09

    To develop a classification based on the technical complexity encountered during pedicle screw insertion and to evaluate the performance of AIRO ® CT navigation system based on this classification, in the clinical scenario of complex spinal deformity. 31 complex spinal deformity correction surgeries were prospectively analyzed for performance of AIRO ® mobile CT-based navigation system. Pedicles were classified according to complexity of insertion into five types. Analysis was performed to estimate the accuracy of screw placement and time for screw insertion. Breach greater than 2 mm was considered for analysis. 452 pedicle screws were inserted (T1-T6: 116; T7-T12: 171; L1-S1: 165). The average Cobb angle was 68.3° (range 60°-104°). We had 242 grade 2 pedicles, 133 grade 3, and 77 grade 4, and 44 pedicles were unfit for pedicle screw insertion. We noted 27 pedicle screw breach (medial: 10; lateral: 16; anterior: 1). Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Average screw insertion time was 1.76 ± 0.89 min. After accounting for planned breach, the effective breach rate was 3.8% resulting in 96.2% accuracy for pedicle screw placement. This classification helps compare the accuracy of screw insertion in range of conditions by considering the complexity of screw insertion. Considering the clinical scenario of complex pedicle anatomy in spinal deformity AIRO ® navigation showed an excellent accuracy rate of 96.2%.

  13. Optimal area of lateral mass mini-screws implanted in plated cervical laminoplasty: a radiography anatomy study.

    PubMed

    Chen, Hua; Li, Huibo; Deng, Yuxiao; Rong, Xin; Gong, Quan; Li, Tao; Song, Yueming; Liu, Hao

    2017-04-01

    Lateral mass mini-screws used in plated cervical laminoplasty might penetrate into facet joints. The objective is to observe this complication incidence and to identify the optimal areas for 5- and 7-mm-long mini-screws to implant on lateral mass. 47 patients who underwent plated cervical laminoplasty were included. The optimal area for mini-screws implanting was set according to pre-operative 3D CT reconstruction data. Then, each posterior-lateral mass surface was divided into three regions: 7-mm region, 5-mm region, and dangerous area. The mini-screw implanted region was recorded. Post-operative CT images were used to identify whether the mini-screws penetrated into facet joints. 235 mini-plates and 470 lateral mass mini-screws were used in the study. 117 (24.9%) mini-screws penetrated 88 (37.4%) facet joints. The 5-mm-long mini-screw optimal area occupied the upper 72, 65, 65, 64, and 65 % area of the posterior-lateral mass surface for C3-7, while the 7-mm-long mini-screw optimal area encompassed the upper 54, 39, 40, 33, and 32 %. Only 7-mm-long mini-screws were used to fix the plate to the lateral mass. 4 of 240 mini-screws in 7-mm region, 67 of the 179 mini-screws in 5-mm region, and 46 of the 51 mini-screws in dangerous region penetrated into the facet joint. The differences in the rate of facet joint penetration related to region were statistically significant (P < 0.001). The facet joint destruction by mini-screws was not a rare complication in plated cervical laminoplasty. The optimal areas we proposed may help guide the mini-screw implantation positions.

  14. Finite element analysis of the axial stiffness of a ball screw

    NASA Astrophysics Data System (ADS)

    Zhou, L.-X.; Li, P.-Y.

    2018-06-01

    The ball screw was developed for high speed and high precision operation; therefore, increasingly greater demands have been placed on the stiffness of the ball screw. Firstly, ANSYS software was used to compare the axial stiffness of a single-nut and single-arc ball screw and a single-nut and double-arc ball screw when the spiral angle is not considered. On this basis, the model of a single-nut ball screw was established taking into consideration the spiral lead angle, and then the variations in displacement and stiffness when the ball screw pair was subjected to an axial force were determined. The axial contact stiffness of the double-nut ball screw pair, subject to a pre-tightening force, was analyzed, according to the above-mentioned steps. The simulation results demonstrated that under the same working conditions, the stiffness of the double-arc ball screw was larger by between 5∼100 N/um than that of the single-arc ball screw. The spiral lead angle increased the axial stiffness of the ball screw pair, and the axial stiffness of the double-nut ball screw pair subject to a pre-tightening force was larger by between 790∼1360 N/um than that of the axial stiffness of the single-nut ball screw pair.

  15. Ball Screw Actuator Including a Stop with an Integral Guide

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  16. Prediction of Deformity Correction by Pedicle Screw Instrumentation in Thoracolumbar Scoliosis Surgery

    NASA Astrophysics Data System (ADS)

    Kiriyama, Yoshimori; Yamazaki, Nobutoshi; Nagura, Takeo; Matsumoto, Morio; Chiba, Kazuhiro; Toyama, Yoshiaki

    In segmental pedicle screw instrumentation, the relationship between the combinations of pedicle screw placements and the degree of deformity correction was investigated with a three-dimensional rigid body and spring model. The virtual thoracolumbar scoliosis (Cobb’s angle of 47 deg.) was corrected using six different combinations of pedicle-screw placements. As a result, better correction in the axial rotation was obtained with the pedicle screws placed at or close to the apical vertebra than with the screws placed close to the end vertebrae, while the correction in the frontal plane was better with the screws close to the end vertebrae than with those close to the apical vertebra. Additionally, two screws placed in the convex side above and below the apical vertebra provided better correction than two screws placed in the concave side. Effective deformity corrections of scoliosis were obtained with the proper combinations of pedicle screw placements.

  17. Synthesis of styrene/isoprene/butadiene integrated rubber with wide glass transition temperature by reactive extrusion

    NASA Astrophysics Data System (ADS)

    Huang, Tianhua; Zheng, Anna; Zhan, Pengfei; Shi, Han; Li, Xiang; Guan, Yong; Wei, Dafu

    2018-05-01

    In this work, styrene/isoprene/butadiene integrated rubber (SIBR) was synthesized with n-butyllithium as the initiator and tetrahydrofuran as structure modifier in a co-rotating intermeshing twin-screw extruder. The content of diene in these terpolymers reached a surprising 70 wt% by feeding the monomers in two different sites of the twin-screw extruder. 1H-NMR, GPC and TEM results showed that the molecular structures of terpolymers changed with the variation of feeding site. Dynamic mechanical analysis of the vulcanized SIBR showed that the terpolymer had a wide glass transition region, which assured an excellent combination of high antiskid properties and low rolling resistance. Different from traditional solution polymerization, the present work provides a green approach to prepare the SIBR via bulk polymerization without solvent.

  18. Fluid dynamic and thermodynamic analysis of a model pertaining to cryogenic fluid management in low gravity environments for a system with dynamically induced settling

    NASA Technical Reports Server (NTRS)

    Rios, J.

    1982-01-01

    The settling behavior of the liquid and gaseous phases of a fluid in a propellant and in a zero-g environment, when such settling is induced through the use of a dynamic device, in this particular case, a helical screw was studied. Particular emphasis was given to: (1) the description of a fluid mechanics model which seems applicable to the system under consideration, (2) a First Law of Thermodynamics analysis of the system, and (3) a discussion of applicable scaling rules.

  19. Atomistic Modeling of Diffusion and Phase Transformations in Metals and Alloys

    NASA Astrophysics Data System (ADS)

    Purja Pun, Ganga Prasad

    Dissertation consists of multiple works. The first part is devoted to self-diffusion along dislocation cores in aluminum followed by the development of embedded atom method potentials for Co, NiAl, CoAl and CoNi systems. The last part focuses on martensitic phase transformation (MPT) in Ni xAl1--x and Al xCoyNi1-- x--y alloys. New calculation methods were developed to predict diffusion coefficients in metal as functions of temperature. Self-diffusion along screw and edge dislocations in aluminum was studied by molecular dynamic (MD) simulations. Three types of simulations were performed with and without (intrinsic) pre-existing vacancies and interstitials in the dislocation core. We found that the diffusion along the screw dislocation was dominated by the intrinsic mechanism, whereas the diffusion along the edge dislocation was dominated by the vacancy mechanism. The diffusion along the screw dislocation was found to be significantly faster than the diffusion along the edge dislocation, and the both diffusivities were in reasonable agreement with experimental data. The intrinsic diffusion mechanism can be associated with the formation of dynamic Frenkel pairs, possibly activated by thermal jogs and/or kinks. The simulations show that at high temperatures the dislocation core becomes an effective source/sink of point defects and the effect of pre-existing defects on the core diffusivity diminishes. First and the foremost ingredient needed in all atomistic computer simulations is the description of interaction between atoms. Interatomic potentials for Co, NiAl, CoAl and CoNi systems were developed within the Embedded Atom Method (EAM) formalism. The binary potentials were based on previously developed accurate potentials for pure Ni and pure Al and pure Co developed in this work. The binaries constitute a version of EAM potential of AlCoNi ternary system. The NiAl potential accurately reproduces a variety of physical properties of the B2-NiAl and L12--Ni3Al phases. The potential is expected to be especially suitable for simulations of hetero-phase interfaces and mechanical behavior of NiAl alloys. Apart from properties of the HCP Co, the new Co potential is accurate enough to reproduce several properties of the FCC Co which were not included in the potential fit. It shows good transferability property. The CoAl potential was fitted to the properties of B2-CoAl phase as in the NiAl fitting where as the NiCo potential was fitted to the ab initio formation energies of some imaginary phases and structures. Effect of chemical composition and uniaxial mechanical stresses was studied on the martensitic phase transformation in B2 type Ni-rich NiAl and AlCoNi alloys. The martensitic phase has a tetragonal crystal structure and can contain multiple twins arranged in domains and plates. The twinned martensites were always formed under the uniaxial compression where as the single variant martensites were the results of the uniaxial tension. The transformation was reversible and characterized by a significant temperature hysteresis. The magnitude of the hysteresis depends on the chemical composition and stress.

  20. Is Polymethyl Methacrylate a Viable Option for Salvaging Lateral Mass Screw Failure in the Subaxial Cervical Spine?

    PubMed Central

    Gallizzi, Michael A.; Kuhns, Craig A.; Jenkins, Tyler J.; Pfeiffer, Ferris M.

    2014-01-01

    Study Design Biomechanical analysis of lateral mass screw pullout strength. Objective We compare the pullout strength of our bone cement–revised lateral mass screw with the standard lateral mass screw. Methods In cadaveric cervical spines, we simulated lateral mass screw “cutouts” unilaterally from C3 to C7. We salvaged fixation in the cutout side with polymethyl methacrylate (PMMA) or Cortoss cement (Orthovita, Malvern, Pennsylvania, United States), allowed the cement to harden, and then drilled and placed lateral mass screws back into the cement-augmented lateral masses. On the contralateral side, we placed standard lateral mass screws into the native, or normal lateral, masses and then compared pullout strength of the cement-augmented side to the standard lateral mass screw. For pullout testing, each augmentation group was fixed to a servohydraulic load frame and a specially designed pullout fixture was attached to each lateral mass screw head. Results Quick-mix PMMA-salvaged lateral mass screws required greater force to fail when compared with native lateral mass screws. Cortoss cement and PMMA standard-mix cement-augmented screws demonstrated less strength of fixation when compared with control-side lateral mass screws. Attempts at a second round of cement salvage of the same lateral masses led to more variations in load to failure, but quick-mix PMMA again demonstrated greater load to failure when compared with the nonaugmented control lateral mass screws. Conclusion Quick-mix PMMA cement revision equips the spinal surgeon with a much needed salvage option for a failed lateral mass screw in the subaxial cervical spine. PMID:25649421

  1. Experiments on the enhancement of compressible mixing via streamwise vorticity. II - Vortex strength assessment and seed particle dynamics

    NASA Technical Reports Server (NTRS)

    Naughton, J. W.; Cattafesta, L. N.; Settles, G. S.

    1993-01-01

    The effect of streamwise vorticity on compressible axisymmetric mixing layers is examined using vortex strength assessment and seed particle dynamics analysis. Experimental results indicate that the particles faithfully represent the dynamics of the turbulent swirling flow. A comparison of the previously determined mixing layer growth rates with the present vortex strength data reveals that the increase of turbulent mixing up to 60 percent scales with the degree of swirl. The mixing enhancement appears to be independent of the compressibility level of the mixing layer.

  2. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    PubMed

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations. This study does not show a substantial benefit between the Screw Targeting Clamp and the freehand technique as well between experienced and inexperienced surgeons. Data suggest that the clamp might help positioning sustentaculum tali screws, especially for inexperienced surgeons. Perioperative 3D recordings facilitate identification of malpositioned screws. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers.

    PubMed

    Malham, Gregory M; Parker, Rhiannon M

    2018-04-01

    OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision. CONCLUSIONS The noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.

  4. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    PubMed

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each specimen. Each pedicle was incrementally tapped to increasing size (3.75, 4.00, 4.50, and 5.50 mm) until the threshold value was reached based on the assigned group. Pedicle screw size was determined by adding 1 mm to the tap size that crossed the threshold torque value. Torque measurements were recorded with each revolution during tap and pedicle screw insertion. Each specimen was then individually potted and pedicle screws pulled out "in-line" with the screw axis at a rate of 0.25 mm/sec. Peak pullout strength (POS) was measured in Newtons (N). The peak tapping IT was significantly increased (50%) in Group 2 (3.23 ± 0.65 in-lbs) compared with Group 1 (2.15 ± 0.56 in-lbs) (p=.0005). The peak screw IT was also significantly increased (19%) in Group 2 (8.99 ± 2.27 in-lbs) compared with Group 1 (7.52 ± 2.96 in-lbs) (p=.02). The pedicle screw pullout strength was also significantly increased (23%) in Group 2 (877.9 ± 235.2 N) compared with Group 1 (712.3 ± 223.1 N) (p=.017). The mean pedicle screw diameter was significantly increased in Group 2 (5.70 ± 1.05 mm) compared with Group 1 (5.00 ± 0.80 mm) (p=.0002). There was also an increased rate of optimal pedicle screw size selection in Group 2 with 9 of 15 (60%) pedicle screws compared with Group 1 with 4 of 15 (26.7%) pedicle screws within 1 mm of the measured pedicle width. There was a moderate correlation for tapping IT with both screw IT (r=0.54; p=.002) and pedicle screw POS (r=0.55; p=.002). Our findings suggest that tapping IT directly correlates with pedicle screw IT, pedicle screw pullout strength, and optimal pedicle screw size. Therefore, tapping IT may be used during thoracic pedicle screw instrumentation as an adjunct to preoperative imaging and clinical experience to maximize fixation strength and optimize pedicle "fit and fill" with the largest screw possible. However, further prospective, in vivo studies are necessary to evaluate the intraoperative use of tapping IT to predict screw loosening/complications. Published by Elsevier Inc.

  5. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners

    PubMed Central

    Kirchberger, Martin

    2016-01-01

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. PMID:26868955

  6. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners.

    PubMed

    Kirchberger, Martin; Russo, Frank A

    2016-02-10

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. © The Author(s) 2016.

  7. A new method to precisely control the depth of percutaneous screws into the pedicle by counting the rotation number of the screw with low radiation exposure: technical note.

    PubMed

    Li, Xu; Zhang, Feng; Zhang, Wenzhi; Shang, Xifu; Han, Jintao; Liu, Pengfei

    2017-03-01

    Technique note. To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. IV.

  8. Fatigue strength of common tibial intramedullary nail distal locking screws

    PubMed Central

    Griffin, Lanny V; Harris, Robert M; Zubak, Joseph J

    2009-01-01

    Background Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of withstanding more than a week of weight bearing. If two small diameter screws are used, our tests showed that the probability of withstanding a week of weight bearing increases from zero to about 20 percent, which is similar to having a single 4.5 mm diameter screw providing fixation. Conclusion Our results show that selecting the system that uses the largest distal locking screws would offer the best fatigue resistance for an unstable fracture pattern subjected to full weight bearing. Furthermore, using multiple screws will substantially reduce the risk of premature hardware failure. PMID:19371438

  9. Dynamic Compression of the Signal in a Charge Sensitive Amplifier: From Concept to Design

    NASA Astrophysics Data System (ADS)

    Manghisoni, Massimo; Comotti, Daniele; Gaioni, Luigi; Ratti, Lodovico; Re, Valerio

    2015-10-01

    This work is concerned with the design of a low-noise Charge Sensitive Amplifier featuring a dynamic signal compression based on the non-linear features of an inversion-mode MOS capacitor. These features make the device suitable for applications where a non-linear characteristic of the front-end is required, such as in imaging instrumentation for free electron laser experiments. The aim of the paper is to discuss a methodology for the proper design of the feedback network enabling the dynamic signal compression. Starting from this compression solution, the design of a low-noise Charge Sensitive Amplifier is also discussed. The study has been carried out by referring to a 65 nm CMOS technology.

  10. The general theory of blade screws including propellers, fans, helicopter screws, helicoidal pumps, turbo-motors, and different kinds of helicoidal blades

    NASA Technical Reports Server (NTRS)

    De Bothezat, George

    1920-01-01

    Report presents a theory which gives a complete picture and an exact quantitative analysis of the whole phenomenon of the working of blade screws, but also unites in a continuous whole the entire scale of states of work conceivable for a blade screw. Chapter 1 is devoted to the establishment of the system of fundamental equations relating to the blade screw. Chapter 2 contains the general discussion of the 16 states of work which may establish themselves for a blade screw. The existence of the vortex ring state and the whirling phenomenon are established. All the fundamental functions which enter the blade-screw theory are submitted to a general analytical discussion. The general outline of the curve of the specific function is examined. Two limited cases of the work of the screw, the screw with a zero constructive pitch and the screw with an infinite constructive pitch, are pointed out. Chapter 3 is devoted to the study of the propulsive screw or propeller. (author)

  11. Research and application of absorbable screw in orthopedics: a clinical review comparing PDLLA screw with metal screw in patients with simple medial malleolus fracture.

    PubMed

    Tang, Jin; Hu, Jin-feng; Guo, Wei-chun; Yu, Ling; Zhao, Sheng-hao

    2013-01-01

    To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics. A total of 129 patients with simple medial malleolus fracture were studied. Among them, 64 patients were treated with poly-D, L-lactic acid (PDLLA) absorbable screws, while the others were treated with metal screws. All the patients were followed up for 12-20 months (averaged 18.4 months) and the therapeutic effect was evaluated according to the American Orthopaedic Foot and Ankle Society clinical rating systems. In absorbable screw group, we obtained excellent and good results in 62 cases (96.88%); in steel screw group, 61 cases (93.85%) achieved excellent and good results. There was no significant difference between the two groups. In the treatment of malleolus fracture, absorbable screw can achieve the same result compared with metal screw fixation. Absorbable screw is preferred due to its advantages of safety, cleanliness and avoiding the removal procedure associated with metallic implants.

  12. Preload evaluation of different screws in external hexagon joint.

    PubMed

    Assunção, Wirley Gonçalves; Delben, Juliana Aparecida; Tabata, Lucas Fernando; Barão, Valentim Adelino Ricardo; Gomes, Erica Alves; Garcia, Idelmo Rangel

    2012-02-01

    This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P > 0.05). All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage.

  13. A compact ball screw based electromagnetic energy harvester for railroad application

    NASA Astrophysics Data System (ADS)

    Pan, Yu; Lin, Teng; Liu, Cheng; Yu, Jie; Zuo, Jianyong; Zuo, Lei

    2018-03-01

    To enable the smart technologies, such as the positive train controls, rail damage detection and track health monitoring on the railroad side, the electricity is required and in needed. In this paper, we proposed a novel ball-screw based electromagnetic energy harvester for railway track with mechanical-motion-rectifier (MMR) mechanism, to harvest the energy that usually dissipated and wasted during train induced track vibration. Ball screw based design reduces backlash during motion transmission, and MMR nonlinear characteristics with one way clutches makes the harvester convert the bi-direction track vibration into a generator's unidirectional rotation, which improves the transmission reliability and increases the energy harvesting efficiency. A systematic model combining train-rail-harvester was established to analyze the dynamic characteristic of the proposed railway energy, and lab and in-field tests were carried out to experimentally characterize the proposed energy harvester. In lab bench test showed the proposed harvester reached a 70% mechanical efficiency with a high sensitivity to the environment vibration. In filed test showed that a peak 7.8W phase power was achieved when a two marshaling type A metro train passed by with a 30 km/h.

  14. Effect of cyclic loading and retightening on reverse torque value in external and internal implants

    PubMed Central

    Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin

    2015-01-01

    PURPOSE The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading. PMID:26330975

  15. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.

    PubMed

    Byrne, Declan; Jacobs, Stuart; O'Connell, Brian; Houston, Frank; Claffey, Noel

    2006-01-01

    Abutment screw loosening, especially in the case of cemented single tooth restorations, is a cause of implant restoration failure. This study compared three screws (titanium alloy, gold alloy, and gold-coated) with similar geometry by recording the preload induced when torques of 10, 20, and 35 Ncm were used for fixation. Two abutment types were used-prefabricated preparable abutments and cast-on abutments. A custom-designed rig was used to measure preload in the abutment-screw-implant assembly with a strain gauge. Ten screws of each type were sequentially tightened to 10, 20, and 35 Ncm on ten of the two abutment types. The same screws were then loosened and re-tightened. This procedure was repeated. Thus, each screw was tightened on three occasions to the three insertion torques. A linear regression model was used to analyze the effects on preload values of screw type and abutment type for each of the three insertion torques. The results indicated that the gold-coated screw generated the highest preloads for all insertion torques and for each tightening episode. Further analysis focused on the effects of screw type and abutment type for each episode of tightening and for each fixation torque. The gold-coated screw, fixed to the prefabricated abutment, displayed higher preloads for the first tightening at 10, 20, and 35 Ncm. Conversely, the same screw fixed to the cast-on abutment showed higher values for the second and third tightening for all fixation torques. All screws showed decay in preload with the number of times tightened. Given the higher preloads generated using the gold-coated screw with both abutment types, it is more likely that this type of screw will maintain a secure joint when tightened for the second and third time. All screw types displayed some decay in preload with repeated tightening, irrespective of abutment type and insertion torque. The gold-coated screw showed markedly higher preloads for all insertion torques and for all instances of tightening when compared with the uncoated screws.

  16. Hollow screw-like drill in plasma using an intense Laguerre–Gaussian laser

    PubMed Central

    Wang, Wenpeng; Shen, Baifei; Zhang, Xiaomei; Zhang, Lingang; Shi, Yin; Xu, Zhizhan

    2015-01-01

    With the development of ultra-intense laser technology, MeV ions can be obtained from laser–foil interactions in the laboratory. These energetic ion beams can be applied in fast ignition for inertial confinement fusion, medical therapy, and proton imaging. However, these ions are mainly accelerated in the laser propagation direction. Ion acceleration in an azimuthal orientation was scarcely studied. In this research, a doughnut Laguerre–Gaussian (LG) laser is used for the first time to examine laser–plasma interaction in the relativistic intensity regime in three-dimensional particle-in-cell simulations. Studies have shown that a novel rotation of the plasma is produced from the hollow screw-like drill of an mode laser. The angular momentum of particles in the longitudinal direction produced by the LG laser is enhanced compared with that produced by the usual laser pulses, such as linearly and circularly polarized Gaussian pulses. Moreover, the particles (including electrons and ions) can be trapped and uniformly compressed in the dark central minimum of the doughnut LG pulse. The hollow-structured LG laser has potential applications in the generation of x-rays with orbital angular momentum, plasma accelerators, fast ignition for inertial confinement fusion, and pulsars in the astrophysical environment. PMID:25651780

  17. Optimisation of mechanical properties of bamboo fibre reinforced-PLA biocomposites

    NASA Astrophysics Data System (ADS)

    Nurnadia M., J.; Fazita, M. R. Nurul; Abdul Khalil H. P., S.; Mohamad Haafiz M., K.

    2017-12-01

    The majority of the raw materials that have been widely used in industries are petroleum-based. Growing environmental awareness, the depletion of fossil fuels, and climate change are the key drivers to seek more ecologically friendly materials, such as natural fibres to replace synthetic fibres in polymeric composite. Among the natural fibres available, bamboo fibre has relatively high strength. Poly (lactic) acid (PLA), one of the well-known biopolymers, has been used as a matrix in order to produce totally biodegradable biocomposites. In this study, bamboo fibres were compounded with PLA by a twin screw extruder. The bamboo fibre reinforced PLA composites were then manufactured via the compression moulding method. The influences of screw speed and die temperature during extrusion on the mechanical properties, the tensile and flexural of the biocomposites, were studied. The effects of fibre content and fibre length were also investigated. Taguchi experimental design approach was adopted to determine the optimum set of conditions to achieve the "best" mechanical properties of the composites. Tensile and flexural properties were characterised based on the D638-10 and D790-10 standards, respectively. It was observed that the fibre aspect ratio and fibre content significantly affected the mechanical performance of bamboo fibres reinforced PLA composites.

  18. Implant Augmentation: Adding Bone Cement to Improve the Treatment of Osteoporotic Distal Femur Fractures

    PubMed Central

    Wähnert, Dirk; Hofmann-Fliri, Ladina; Richards, R. Geoff; Gueorguiev, Boyko; Raschke, Michael J.; Windolf, Markus

    2014-01-01

    Abstract The increasing problems in the field of osteoporotic fracture fixation results in specialized implants as well as new operation methods, for example, implant augmentation with bone cement. The aim of this study was to determine the biomechanical impact of augmentation in the treatment of osteoporotic distal femur fractures. Seven pairs of osteoporotic fresh frozen distal femora were randomly assigned to either an augmented or nonaugmented group. In both groups, an Orthopaedic Trauma Association 33 A3 fractures was fixed using the locking compression plate distal femur and cannulated and perforated screws. In the augmented group, additionally, 1 mL of polymethylmethacrylate cement was injected through the screw. Prior to mechanical testing, bone mineral density (BMD) and local bone strength were determined. Mechanical testing was performed by cyclic axial loading (100 N to 750 N + 0.05N/cycle) using a servo-hydraulic testing machine. As a result, the BMD as well as the axial stiffness did not significantly differ between the groups. The number of cycles to failure was significantly higher in the augmented group with the BMD as a significant covariate. In conclusion, cement augmentation can significantly improve implant anchorage in plating of osteoporotic distal femur fractures. PMID:25415673

  19. Standard Waste Box Lid Screw Removal Option Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anast, Kurt Roy

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  20. Evaluation of Titanium-Coated Pedicle Screws: In Vivo Porcine Lumbar Spine Model.

    PubMed

    Kim, Do-Yeon; Kim, Jung-Ryul; Jang, Kyu Yun; Kim, Min Gu; Lee, Kwang-Bok

    2016-07-01

    Many studies have addressed the problem of loosening pedicle screws in spinal surgery, which is a serious concern. Titanium coating of medical implants (arthroplasty) is common, but few studies involving in vivo spine models have been reported. We evaluated the radiological, mechanical, and histological characteristics of titanium-coated pedicle screws compared with uncoated or hydroxyapatite-coated pedicle screws. Three different types of pedicle screws, i.e., uncoated, hydroxyapatite-coated, and titanium-coated, were implanted into the lumbar 3-4-5 levels of 9 mature miniature pigs. Radiological evaluation of loosening of pedicle screws was performed. Peak torsional extraction torque was tested in the 42 screws from 7 miniature pigs at 12 weeks postoperatively. The implant-bone interface of the remaining 12 pedicle screws from 2 miniature pigs in each group was assessed by micro-computed tomography and histologic studies. The incidence of loosening at 12 weeks postoperatively was not significantly different between the titanium-coated pedicle screw group and the other groups. The titanium-coated pedicle screw group exhibited the greatest mean extraction torsional peak torque at 12 weeks postoperatively (P < 0.05). Quantitative micro-computed tomography data were greatest in the titanium-coated pedicle screw group (P < 0.05). Histologic findings showed osteointegration with densely packed new bone formation at the screw coating-bone interface in the titanium-coated pedicle screw group. Fixation strength was greatest in the titanium-coated pedicle screw group. Osteointegration at the interface between the titanium-coated implant and bone produced prominent and firm bonding. The titanium-coated pedicle screw is a promising device for application in spinal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Is tip apex distance as important as we think? A biomechanical study examining optimal lag screw placement.

    PubMed

    Kane, Patrick; Vopat, Bryan; Heard, Wendell; Thakur, Nikhil; Paller, David; Koruprolu, Sarath; Born, Christopher

    2014-08-01

    Intertrochanteric hip fractures pose a significant challenge for the orthopaedic community as optimal surgical treatment continues to be debated. Currently, varus collapse with lag screw cutout is the most common mode of failure. Multiple factors contribute to cutout. From a surgical technique perspective, a tip apex distance less than 25 mm has been suggested to decrease the risk of cutout. We hypothesized that a low-center lag screw position in the femoral head, with a tip apex distance greater than 25 mm will provide equal, if not superior, biomechanical stability compared with a center-center position with a tip apex distance less than 25 mm in an unstable intertrochanteric hip fracture stabilized with a long cephalomedullary nail. We attempted to examine the biomechanical characteristics of intertrochanteric fractures instrumented with long cephalomedullary nails with two separate lag screw positions, center-center and low-center. Our first research purpose was to examine if there was a difference between the center-center and low-center groups in cycles to failure and failure load. Second, we analyzed if there was a difference in fracture translation between the study groups during loading. Nine matched pairs of femurs were assigned to one of two treatment groups: low-center lag screw position and center-center lag screw position. Cephalomedullary nails were placed and tip apex distance was measured. A standard unstable four-part intertrochanteric fracture was created in all samples. The femurs were loaded dynamically until failure. Cycles to failure and load and displacement data were recorded, and three-dimensional (3-D) motion was recorded using an Optotrak(®) motion tracking system. There were no significant differences between the low-center and center-center treatment groups regarding the mean number of cycles to failure and mean failure load. The 3-D kinematic data showed significantly increased motion in the center-center group compared with the low-center group. At the time of failure, the magnitude of fracture translation was statistically significantly greater in the center-center group (20 ± 2.8 mm) compared with the low-center group (15 ± 3.4 mm; p = 0.004). Additionally, there was statistically significantly increased fracture gap distraction (center-center group, 13 ± 2.8 versus low-center group, 7 ± 4; p < 0.001) and shear fracture gap translation (center-center group, 12 ± 2.3 mm; low-center group, 6 ± 2.7 mm; p < 0.001). Positioning of the lag screw inferior in the head and neck was found to be at least as biomechanically stable as the center-center group although the tip apex distance was greater than 25 mm. Our findings challenge previously accepted principles of optimal lag screw placement.

  2. Mechanical and photoelastic analysis of conventional screws and cannulated screws for sagittal split osteotomy fixation: a comparative study.

    PubMed

    Lima, Cristina Jardelino de; Falci, Saulo Gabriel Moreira; Rodrigues, Danillo Costa; Marchiori, Érica Cristina; Moreira, Roger Willian Fernandes

    2015-12-01

    The aim of the present study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with solid-core screws in sagittal split osteotomy fixation. Ten polyurethane mandibles, with a prefabricated sagittal split ramus osteotomy, were fixed with an L inverted technique and allocated to each group as follows: cannulated screw group (CSG), fixed with three 2.3-cannulated screws; and solid-core screw group (SCSG), fixed with three 2.3-solid-core screws. Vertical linear loading tests were performed. The differences between mean values were analyzed through T test for independent samples. The photoelastic test was carried out using a polariscope. The results revealed differences between the two groups only at 1 mm of displacement, in which the cannulated-screw revealed more resistance. Photoelastic test showed higher stress concentration close to mandibular branch in the solid-core group. Cannulated screws performed better than solid-core ones in a mechanical test at 1-mm displacement and photoelastic tests.

  3. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A

    2005-01-01

    To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.

  4. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study.

    PubMed

    Nikoloski, Andrej N; Osbrough, Anthony L; Yates, Piers J

    2013-10-17

    Unstable proximal femoral fractures are common and challenging for the orthopaedic surgeon. Often, these are treated with intramedullary nails. The most common mode of failure of any device to treat these fractures is cut-out. The Synthes proximal femoral nail antirotation (PFNA) is unique because it is the only proximal femoral intramedullary nail which employs a helical blade in lieu of a lag screw. The optimal tip-apex distance is 25 mm or less for a dynamic hip screw. The optimal blade tip placement is not known for the PFNA. The aim of this study is to determine if the traditional tip-apex distance rule (<25 mm) applies to the PFNA. A retrospective study of all proximal femoral fractures treated with the PFNA in Western Australian public teaching hospitals between August 2006 and October 2007 was performed. Cases were identified from company and theatre implant use records. Patient demographic data was obtained from hospital records. Fractures were classified according to Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of Internal Fixation. Fracture reduction, distal locking type and blade position within the head (tip-apex distance and Cleveland zone) were recorded from the intraoperative and immediate postoperative radiographs. Postoperative radiographs obtained in the routine treatment of patients were studied for review looking primarily for cut-out. Clinical outcomes were measured with the Oxford hip score. One hundred eighty-eight PFNAs were implanted during the study period, with 178 cases included in this study. Ninety-seven patients could be followed up clinically. There were 18 surgical implant-related failures (19%). The single most common mode of failure was cut-out in six cases (6.2%). Three cut-outs (two medial perforation and one varus collapse) occurred with tip-apex distance (TAD) less than 20 mm. There was no cut-out in cases where the TAD was from 20-30 mm. There were three implant-related failures (nail fracture, missed nail and loose locking screw), four implant-related femoral fractures, two non-unions, two delayed unions and one loss of reduction. The PFNA is a suitable fixation device for the treatment of unstable proximal femoral fractures. There were still a relatively large number of cut-outs, and the tip-apex distance in the failures showed a bimodal distribution, not like previously demonstrated with dynamic hip screw. We propose that the helical blade behaves differently to a screw, and placement too close to the subchondral bone may lead to penetration through the head.

  5. Comparison of computer assisted surgery with conventional technique for treatment of abaxial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A

    2008-01-01

    To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.

  6. Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests.

    PubMed

    Leslie, Laura Jane; Connolly, Ashley; Swadener, John G; Junaid, Sarah; Theivendran, Kanthan; Deshmukh, Subodh C

    2018-06-01

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.

  7. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note.

    PubMed

    Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T

    2018-04-17

    Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

  8. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    NASA Astrophysics Data System (ADS)

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  9. Compression properties and dissolution of bioactive glass S53P4 and n-butyl-2 cyanoacrylate tissue adhesive-composite.

    PubMed

    Sarin, Jussi; Hiltunen, Markus; Hupa, Leena; Pulkkinen, Jaakko; Vallittu, Pekka K

    2016-09-28

    Bioactive glass (BG)-containing fiber-reinforced composite implants, typically screw-retained, have started to be used clinically. In this study, we tested the mechanical strength of composites formed by a potential implant adhesive of n-butyl-2-cyanoacrylate glue and BG S53P4 particles. Water immersion for 3, 10 or 30 days had no adverse effect on the compression strength. When cyanoacrylate glue-BG-composites were subjected to simulated body fluid immersion, the average pH rose to 7.52 (SD 0.066) from the original value of 7.35 after 7 days, and this pH increment was smaller compared to BG particle-group or fibrin glue-BG-composite group. Based on these results n-butyl-2 cyanoacrylate glue, by potentially producing a strong adhesion, might be considered a possible alternative for fixation of BG S53P4 containing composite implants. However, the mechanical and solubility properties of the cyanoacrylate glue may not encourage the use of this tissue adhesive with BG particles.

  10. Fixation of osteoporotic fractures in the upper limb with a locking compression plate.

    PubMed

    Neuhaus, V; King, J D; Jupiter, J B

    2012-01-01

    Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

  11. The influence of the insertion technique on the pullout force of pedicle screws: an experimental study.

    PubMed

    Chatzistergos, Panagiotis E; Sapkas, George; Kourkoulis, Stavros K

    2010-04-20

    The pullout strength of a typical pedicle screw was evaluated experimentally for different screw insertion techniques. OBJECTIVE.: To conclude whether the self-tapping insertion technique is indeed the optimum one for self-tapping screws, with respect to the pullout strength. It is reported in the literature that the size of the pilot-hole significantly influences the pullout strength of a self-tapping screw. In addition it is accepted that an optimum value of the diameter of the pilot-hole exists. For non self-tapping screw insertion it is reported that undertapping of the pilot-hole can increase its pullout strength. Finally it is known that in some cases orthopedic surgeons open the threaded holes, using another screw instead of a tap. A typical commercial self-tapping pedicle screw was inserted into blocks of Solid Rigid Polyurethane Foam (simulating osteoporotic cancellous bone), following different insertion techniques. The pullout force was measured according to the ASTM-F543-02 standard. The screw was inserted into previously prepared holes of different sizes, either threaded or cylindrical, to conclude whether an optimum size of the pilot-hole exists and whether tapping can increase the pullout strength. The case where the tapping is performed using another screw was also studied. For screw insertion with tapping, decreasing the outer radius of the threaded hole from 1.00 to 0.87 of the screw's outer radius increased the pullout force 9%. For insertion without tapping, decreasing the pilot-hole's diameter from 0.87 to 0.47 of the screw's outer diameter increased its pullout force 75%. Finally, tapping using another screw instead of a tap, gave results similar to those of conventional tapping. Undertapping of a pilot-hole either using a tap or another screw can increase the pullout strength of self-tapping pedicle screws.

  12. Estimation of static parameters based on dynamical and physical properties in limestone rocks

    NASA Astrophysics Data System (ADS)

    Ghafoori, Mohammad; Rastegarnia, Ahmad; Lashkaripour, Gholam Reza

    2018-01-01

    Due to the importance of uniaxial compressive strength (UCS), static Young's modulus (ES) and shear wave velocity, it is always worth to predict these parameters from empirical relations that suggested for other formations with same lithology. This paper studies the physical, mechanical and dynamical properties of limestone rocks using the results of laboratory tests which carried out on 60 the Jahrum and the Asmari formations core specimens. The core specimens were obtained from the Bazoft dam site, hydroelectric supply and double-curvature arch dam in Iran. The Dynamic Young's modulus (Ed) and dynamic Poisson ratio were calculated using the existing relations. Some empirical relations were presented to estimate uniaxial compressive strength, as well as static Young's modulus and shear wave velocity (Vs). Results showed the static parameters such as uniaxial compressive strength and static Young's modulus represented low correlation with water absorption. It is also found that the uniaxial compressive strength and static Young's modulus had high correlation with compressional wave velocity and dynamic Young's modulus, respectively. Dynamic Young's modulus was 5 times larger than static Young's modulus. Further, the dynamic Poisson ratio was 1.3 times larger than static Poisson ratio. The relationship between shear wave velocity (Vs) and compressional wave velocity (Vp) was power and positive with high correlation coefficient. Prediction of uniaxial compressive strength based on Vp was better than that based on Vs . Generally, both UCS and static Young's modulus (ES) had good correlation with Ed.

  13. Molecular Simulations of Dynamic Processes of Solid Explosives

    DTIC Science & Technology

    2004-12-01

    compression. Therefore, we analyzed the dynamics of the energetic crystals RDX , HMX , HNIW and PETN under hydrostatic compression conditions using...for the RDX , HMX and HNIW crystals were found in good agreement with experimental values over the entire range of pressures investigated...Theoretical studies of the hydrostatic compression of RDX , HMX , HNIW, and PETN crystals, J. Phys. Chem. B 103, 6783. scu, D. C.; Rice, B. M. and

  14. Zoledronic acid infusion for lumbar interbody fusion in osteoporosis.

    PubMed

    Tu, Chao-Wei; Huang, Kuo-Feng; Hsu, Hsien-Ta; Li, Hung-Yu; Yang, Stephen Shei-Dei; Chen, Yi-Chu

    2014-11-01

    Clinical outcomes of intravenous (IV) infusion of zoledronic acid (ZOL) for lumbar interbody fusion surgery (LIFS) remain unknown. We investigated the efficacy of IV ZOL on clinical outcome and bone fusion after LIFS. We retrospectively analyzed 64 patients with both degenerative lumbar spondylolisthesis and osteoporosis who underwent LIFS from January 2007 to April 2010. All patients were followed up for 2 y. Thirty-two were treated with an IV infusion of ZOL 3 d after surgery and a second injection 1 y later, and the other 32 patients did not receive ZOL. Preoperatively and every 3 mo postoperatively, oswestry disability index questionnaire and visual analog scale (VAS) scores for back and leg were compared. Preoperative and final postoperative follow-up to evaluate for subsequent compression fractures were also performed. Pedicle screw loosening, cage subsidence, and fusion rate were documented 2 y after surgery. At 2-y follow-up, a solid fusion was achieved in 75% of the ZOL group and only 56% of the control group. At final follow up, the incidence of final subsequent vertebral compression fractures (19% of the ZOL group and 51% of the control group, P = 0.006), pedicle screw loosening (18% of the ZOL group and 45% of the control group, P = 0.03), and cage subsidence >2 mm (28% of the ZOL group and only 54% of the control group, P = 0.04) were significantly lower in the ZOL group than in the control group. The ZOL group demonstrated improvement in VAS (for leg pain VAS, 2/10 for the ZOL group and 5/10 for the control group; for back pain VAS, 2/10 for the ZOL group and 6/10 for the control group) and oswestry disability index scores (7/25 for the ZOL group and 16/25 for the control group). ZOL treatment has beneficial effects on instrumented LIFS both radiographic and clinically. Thus, ZOL treatment can be recommended for osteoporosis patients undergoing LIFS. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Turbulence in Compressible Flows

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Lecture notes for the AGARD Fluid Dynamics Panel (FDP) Special Course on 'Turbulence in Compressible Flows' have been assembled in this report. The following topics were covered: Compressible Turbulent Boundary Layers, Compressible Turbulent Free Shear Layers, Turbulent Combustion, DNS/LES and RANS Simulations of Compressible Turbulent Flows, and Case Studies of Applications of Turbulence Models in Aerospace.

  16. Production and characterization of novel starch and poly(butylene adipate-co-terephthalate)-based materials and their applications

    NASA Astrophysics Data System (ADS)

    Stagner, Jacqueline Ann

    This work focuses on the production and characterization of blends of maleated thermoplastic starch (MTPS) and poly(butylenes adipate-co-terephthalate) and their application for use as thermoformed objects, films, and foams. First, by the production and characterization of maleated thermoplastic starch (MTPS) synthesized by reactive extrusion in a twin-screw extruder, a better understanding of MTPS was gained. This reactive thermoplastic starch was prepared with glycerol as the plasticizer, maleic anhydride (MA), and free-radical initiator, 2,5-bis(tert-butylperoxy)-2,5-dimethylhexane (Luperox 101). Dynamic light scattering (DLS), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), soxhlet extraction in acetone, and environmental scanning electron microscopy (ESEM) were performed to determine the effect of maleation, extrusion temperature, initiator concentration, and maleic anhydride concentration on the resulting MTPS. Next, maleated thermoplastic starch (MTPS) and thermoplastic starch (TPS) were reactively blended in a twin-screw extruder with a biodegradable polyester, poly(butylene adipate-co-terephthalate) (PBAT). The blends were extruded to produce thermoformable sheets. The mechanical properties of the sheets were characterized by tensile and puncture tests. Proof of grafting was determined by soxhlet extraction in dichloromethane and FTIR analysis. Observations of the thermal properties were made using DSC, while the surface of the sheets was imaged using ESEM. Blends of MTPS and PBAT were also extruded to produce films. Mechanical testing (tensile and puncture tests) and barrier performance testing (carbon dioxide, oxygen, and water vapor permeability) were performed on the films. Transmission electron microscopy (TEM) was used to image the blends and to view the dispersion of the various phases. Finally, blends of MTPS and PBAT were extruded with an endothermic chemical blowing agent to produce foams. The foams were characterized by measuring density, expansion ratio, specific length, compressive strength, resiliency, and moisture sorption. Also, digital light microscopy was used to image the cell structure of the foams. This work demonstrates that blends of starch and PBAT can be produced and formed into thermoformed objects, films, and foams. These objects can replace current objects made from non-biodegradable, petroleum-based plastics. By blending the starch and PBAT together, one receives advantages over using either component separately.

  17. Edge-preserving image compression for magnetic-resonance images using dynamic associative neural networks (DANN)-based neural networks

    NASA Astrophysics Data System (ADS)

    Wan, Tat C.; Kabuka, Mansur R.

    1994-05-01

    With the tremendous growth in imaging applications and the development of filmless radiology, the need for compression techniques that can achieve high compression ratios with user specified distortion rates becomes necessary. Boundaries and edges in the tissue structures are vital for detection of lesions and tumors, which in turn requires the preservation of edges in the image. The proposed edge preserving image compressor (EPIC) combines lossless compression of edges with neural network compression techniques based on dynamic associative neural networks (DANN), to provide high compression ratios with user specified distortion rates in an adaptive compression system well-suited to parallel implementations. Improvements to DANN-based training through the use of a variance classifier for controlling a bank of neural networks speed convergence and allow the use of higher compression ratios for `simple' patterns. The adaptation and generalization capabilities inherent in EPIC also facilitate progressive transmission of images through varying the number of quantization levels used to represent compressed patterns. Average compression ratios of 7.51:1 with an averaged average mean squared error of 0.0147 were achieved.

  18. Electroencephalographic compression based on modulated filter banks and wavelet transform.

    PubMed

    Bazán-Prieto, Carlos; Cárdenas-Barrera, Julián; Blanco-Velasco, Manuel; Cruz-Roldán, Fernando

    2011-01-01

    Due to the large volume of information generated in an electroencephalographic (EEG) study, compression is needed for storage, processing or transmission for analysis. In this paper we evaluate and compare two lossy compression techniques applied to EEG signals. It compares the performance of compression schemes with decomposition by filter banks or wavelet Packets transformation, seeking the best value for compression, best quality and more efficient real time implementation. Due to specific properties of EEG signals, we propose a quantization stage adapted to the dynamic range of each band, looking for higher quality. The results show that the compressor with filter bank performs better than transform methods. Quantization adapted to the dynamic range significantly enhances the quality.

  19. Improved Screw-Thread Lock

    NASA Technical Reports Server (NTRS)

    Macmartin, Malcolm

    1995-01-01

    Improved screw-thread lock engaged after screw tightened in nut or other mating threaded part. Device does not release contaminating material during tightening of screw. Includes pellet of soft material encased in screw and retained by pin. Hammer blow on pin extrudes pellet into slot, engaging threads in threaded hole or in nut.

  20. Reliability of roentgenogram evaluation of pedicle screw position.

    PubMed

    Ferrick, M R; Kowalski, J M; Simmons, E D

    1997-06-01

    This was a human cadaver study of the accuracy of biplanar roentgenography in determining pedicle screw position. To determine the independent accuracy of radiologic evaluation of screw placement and to determine if there are any particular screw malpositions that are more likely to produce a false sense of acceptable screw position. Other investigators have reported the correlation between radiologic evaluation and anatomic dissection. However, in those studies the radiologic evaluation was not independent of the surgeons placing the screws. There has been no comment in the literature regarding particular screw malpositions that would lead the surgeon into a false sense of successful screw placement. Pedicle screws were placed in cadaver spines, and biplanar roentgenograms of the specimens were evaluated by independent observers. The results of the roantgenogram evaluation then were compared to those of the anatomic dissection. The accuracy of roentgenogram evaluation varied from 73% to 83%, depending on the experience of the surgeon grading the roentgenograms. Screws misplaced medially into the spinal canal are more likely to give the surgeon a false sense of successful screw placement. The surgeon must not rely solely on the roentgenograms, but instead continue to use tactile sensory skills, anatomic knowledge, and additional modalities such as electromyography monitoring.

  1. Comparison of contemporary occipitocervical instrumentation techniques with and without C1 lateral mass screws.

    PubMed

    Wolfla, Christopher E; Salerno, Simon A; Yoganandan, Narayan; Pintar, Frank A

    2007-09-01

    This study was designed to test the kinematic properties of three occiput-C2 instrumentation constructs with and without supplemental rigid C1 fixation. The results are compared with intact specimens and with constructs incorporating contemporary cabling techniques. Five unembalmed human cadaver specimens underwent range of motion (ROM) testing in the intact condition, followed by destabilization with odontoid osteotomy. Destabilized specimens then underwent ROM testing with each of seven occipitocervical instrumentation constructs, all incorporating occipital screws: C1 and C2 sublaminar cables with cable connectors, C2 pars screws +/- C1 lateral mass screws, C2 lamina screws +/- C1 lateral mass screws, and C1-C2 transarticular screws +/- C1 lateral mass screws. All seven constructs demonstrated significantly lower ROM in all loading modes than intact specimens (P < 0.05). With a single exception, the addition of C1 lateral mass screws to the screw-based constructs produced no significant change in ROM in any of the loading modes. Compared with intact specimens, constructs anchored by C1-C2 transarticular screws demonstrated the greatest decrease in ROM, and those anchored by sublaminar cables demonstrated the least decrease in ROM. Any of the tested screw-based constructs are likely to provide adequate support for the patient with an unstable craniocervical junction. Therefore, the choice of construct should be based on anatomic considerations. The routine incorporation of C1 lateral mass screws into occipitocervical instrumentation constructs does not seem necessary.

  2. Screw-locking wrench

    NASA Technical Reports Server (NTRS)

    Vranish, John M. (Inventor)

    2007-01-01

    A tool comprises a first handle and a second handle, each handle extending from a gripping end portion to a working end portion, the first handle having first screw threads disposed circumferentially about an inner portion of a first through-hole at the working end portion thereof, the second handle having second screw threads disposed circumferentially about an inner portion of a second through-hole at the working end portion thereof, the first and second respective through-holes being disposed concentrically about a common axis of the working end portions. First and second screw locks preferably are disposed concentrically with the first and second respective through-holes, the first screw lock having a plurality of locking/unlocking screw threads for engaging the first screw threads of the first handle, the second screw lock having a plurality of locking/unlocking screw threads for engaging the second screw threads of the second handle. A locking clutch drive, disposed concentrically with the first and second respective through-holes, engages the first screw lock and the second screw lock. The first handle and the second handle are selectively operable at their gripping end portions by a user using a single hand to activate the first and second screw locks to lock the locking clutch drive for either clockwise rotation about the common axis, or counter-clockwise rotation about the common axis, or to release the locking clutch drive so that the handles can be rotated together about the common axis either the clockwise or counter-clockwise direction without rotation of the locking clutch drive.

  3. Mechanical and histological analysis of bone-pedicle screw interface in vivo: titanium versus stainless steel.

    PubMed

    Sun, C; Huang, G; Christensen, F B; Dalstra, M; Overgaard, S; Bünger, C

    1999-05-01

    To investigate the differences in bone interface between titanium and stainless steel pedicle screws in the lumbar spine. Eighteen adult mini-pigs that underwent total laminectomy, posterolateral spinal fusion (L4-L5) were randomly selected to receive stainless steel (9) or titanium pedicle screw devices (9). In both groups, the devices were CCD (Sofamore Danek) type with the same size and shape. The postoperative observation time was 3 months. Screws from L4 were harvested along their long axis of pedicle for histomorphometric study. Bone-screw interface and bone volume from thread were examined using linear intercept techniques. Mechanical testing (torsional test and pull-out test) was performed on the screws from L5. The titanium screw group had a significantly higher maximum torque (P < 0.05) and angle related stiffness (P < 0.05) measured by torsional test. In the pull-out tests, no differences were found between the two groups in relation to the maximum load, stiffness and energy to failure. Direct bone contact with the screw in percentage was 29.4% for stainless steel and 43.8% for titanium (P < 0.05). No differences in the bone purchase between the vertebral body part and pedicle part were found. Pedicle screws made of titanium have a better bone-screw interface binding than screws made of stainless steel. Torsional tests are more informative for bone-screw interface study. Pull-out tests seem less valuable when comparing bone purchase of screws made from different materials.

  4. Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws.

    PubMed

    Zipprich, Holger; Rathe, Florian; Pinz, Sören; Schlotmann, Luca; Lauer, Hans-Christoph; Ratka, Christoph

    The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.

  5. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 2: Metallurgical and microhardness analysis.

    PubMed

    Al Jabbari, Youssef; Fournelle, Raymond; Ziebert, Gerald; Toth, Jeffrey; Iacopino, Anthony

    2008-04-01

    This study involved testing and analyzing multiple retrieved prosthetic retaining screws after long-term use in vivo to: (1) detect manufacturing defects that could affect in-service behavior; (2) characterize the microstructure and alloy composition; and (3) further characterize the wear mechanism of the screw threads. Two new (control) screws from Nobel Biocare (NB) and 18 used (in service 18-120 months) retaining screws [12 from NB and 6 from Sterngold (SG)] were: (1) metallographically examined by light microscopy and scanning electron microscopy (SEM) to determine the microstructure; (2) analyzed by energy dispersive X-ray (EDX) microanalysis to determine the qualitative and semiquantitative average alloy and individual phase compositions; and (3) tested for Vickers microhardness. Examination of polished longitudinal sections of the screws using light microscopy revealed a significant defect in only one Group 4 screw. No significant defects in any other screws were observed. The defect was considered a "seam" originating as a "hot tear" during original casting solidification of the alloy. Additionally, the examination of longitudinal sections of the screws revealed a uniform homogeneous microstructure in some groups, while in other groups the sections exhibited rows of second phase particles. The screws for some groups demonstrated severe deformation of the lower threads and the bottom part of the screw leading to the formation of crevices and grooves. Some NB screws were comprised of Au-based alloy with Pt, Cu, and Ag as alloy elements, while others (Groups 4 and 19) were Pd-based with Ga, Cu, and Au alloy elements. The microstructure was homogeneous with fine or equiaxed grains for all groups except Group 4, which appeared inhomogeneous with anomalous grains. SG screws demonstrated a typical dendritic structure and were Au-based alloy with Cu and Ag alloy elements. There were differences in the microhardness of gold alloy screws from NB and SG as well as palladium alloy screws from NB. Significant differences within NB retaining screws and between NB and SG screws were found for microstructure, major alloy constituents, and microhardness.

  6. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.

    PubMed

    Kawaguchi, Yoshiharu; Nakano, Masato; Yasuda, Taketoshi; Seki, Shoji; Hori, Takeshi; Kimura, Tomoatsu

    2012-11-01

    We developed a new technique for cervical pedicle screw and Magerl screw insertion using a 3-dimensional image guide. In posterior cervical spinal fusion surgery, instrumentation with screws is virtually routine. However, malpositioning of screws is not rare. To avoid complications during cervical pedicle screw and Magerl screw insertion, the authors developed a new technique which is a mold shaped to fit the lamina. Cervical pedicle screw fixation and Magerl screw fixation provide good correction of cervical alignment, rigid fixation, and a high fusion rate. However, malpositioning of screws is not a rare occurrence, and thus the insertion of screws has a potential risk of neurovascular injury. It is necessary to determine a safe insertion procedure for these screws. Preoperative computed tomographic (CT) scans of 1-mm slice thickness were obtained of the whole surgical area. The CT data were imported into a computer navigation system. We developed a 3-dimensional full-scale model of the patient's spine using a rapid prototyping technique from the CT data. Molds of the left and right sides at each vertebra were also constructed. One hole (2.0 mm in diameter and 2.0 cm in length) was made in each mold for the insertion of a screw guide. We performed a simulated surgery using the bone model and the mold before operation in all patients. The mold was firmly attached to the surface of the lamina and the guide wire was inserted using the intraoperative image of lateral vertebra. The proper insertion point, direction, and length of the guide were also confirmed both with the model bone and the image intensifier in the operative field. Then, drilling using a cannulated drill and tapping using a cannulated tapping device were carried out. Eleven consecutive patients who underwent posterior spinal fusion surgery using this technique since 2009 are included. The screw positions in the sagittal and axial planes were evaluated by postoperative CT scan to check for malpositioning. The screw insertion was done in the same manner as the simulated surgery. With the aid of this guide the pedicle screws and Magerl screws could be easily inserted even at the level where the pedicle seemed to be very thin and sclerotic on the CT scan. Postoperative CT scan showed that there were no critical breaches of the screws. This method employing the device using a 3-dimensional image guide seems to be easy and safe to use. The technique may improve the safety of pedicle screw and Magerl screw insertion even in difficult cases with narrow sclerotic pedicles.

  7. Deciphering Mechanical Regulation of Chondrogenesis in Fibrin–Polyurethane Composite Scaffolds Enriched with Human Mesenchymal Stem Cells: A Dual Computational and Experimental Approach

    PubMed Central

    Stoddart, Martin; Lezuo, Patrick; Forkmann, Christoph; Wimmmer, Markus A.; Alini, Mauro; Van Oosterwyck, Hans

    2014-01-01

    Fibrin–polyurethane composite scaffolds support chondrogenesis of human mesenchymal stem cells (hMSCs) derived from bone marrow and due to their robust mechanical properties allow mechanical loading in dynamic bioreactors, which has been shown to increase the chondrogenic differentiation of MSCs through the transforming growth factor beta pathway. The aim of this study was to use the finite element method, mechanical testing, and dynamic in vitro cell culture experiments on hMSC-enriched fibrin–polyurethane composite scaffolds to quantitatively decipher the mechanoregulation of chondrogenesis within these constructs. The study identified compressive principal strains as the key regulator of chondrogenesis in the constructs. Although dynamic uniaxial compression did not induce chondrogenesis, multiaxial loading by combined application of dynamic compression and interfacial shear induced significant chondrogenesis at locations where all the three principal strains were compressive and had a minimum magnitude of 10%. In contrast, no direct correlation was identified between the level of pore fluid velocity and chondrogenesis. Due to the high permeability of the constructs, the pore fluid pressures could not be increased sufficiently by mechanical loading, and instead, chondrogenesis was induced by triaxial compressive deformations of the matrix with a minimum magnitude of 10%. Thus, it can be concluded that dynamic triaxial compressive deformations of the matrix is sufficient to induce chondrogenesis in a threshold-dependent manner, even where the pore fluid pressure is negligible. PMID:24199606

  8. Influence of Selected Factors on the Relationship between the Dynamic Elastic Modulus and Compressive Strength of Concrete

    PubMed Central

    Jurowski, Krystian; Grzeszczyk, Stefania

    2018-01-01

    In this paper, the relationship between the static and dynamic elastic modulus of concrete and the relationship between the static elastic modulus and compressive strength of concrete have been formulated. These relationships are based on investigations of different types of concrete and take into account the type and amount of aggregate and binder used. The dynamic elastic modulus of concrete was tested using impulse excitation of vibration and the modal analysis method. This method could be used as a non-destructive way of estimating the compressive strength of concrete. PMID:29565830

  9. Influence of Selected Factors on the Relationship between the Dynamic Elastic Modulus and Compressive Strength of Concrete.

    PubMed

    Jurowski, Krystian; Grzeszczyk, Stefania

    2018-03-22

    In this paper, the relationship between the static and dynamic elastic modulus of concrete and the relationship between the static elastic modulus and compressive strength of concrete have been formulated. These relationships are based on investigations of different types of concrete and take into account the type and amount of aggregate and binder used. The dynamic elastic modulus of concrete was tested using impulse excitation of vibration and the modal analysis method. This method could be used as a non-destructive way of estimating the compressive strength of concrete.

  10. Simulating coupled dynamics of a rigid-flexible multibody system and compressible fluid

    NASA Astrophysics Data System (ADS)

    Hu, Wei; Tian, Qiang; Hu, HaiYan

    2018-04-01

    As a subsequent work of previous studies of authors, a new parallel computation approach is proposed to simulate the coupled dynamics of a rigid-flexible multibody system and compressible fluid. In this approach, the smoothed particle hydrodynamics (SPH) method is used to model the compressible fluid, the natural coordinate formulation (NCF) and absolute nodal coordinate formulation (ANCF) are used to model the rigid and flexible bodies, respectively. In order to model the compressible fluid properly and efficiently via SPH method, three measures are taken as follows. The first is to use the Riemann solver to cope with the fluid compressibility, the second is to define virtual particles of SPH to model the dynamic interaction between the fluid and the multibody system, and the third is to impose the boundary conditions of periodical inflow and outflow to reduce the number of SPH particles involved in the computation process. Afterwards, a parallel computation strategy is proposed based on the graphics processing unit (GPU) to detect the neighboring SPH particles and to solve the dynamic equations of SPH particles in order to improve the computation efficiency. Meanwhile, the generalized-alpha algorithm is used to solve the dynamic equations of the multibody system. Finally, four case studies are given to validate the proposed parallel computation approach.

  11. High frequency dynamic engine simulation. [TF-30 engine

    NASA Technical Reports Server (NTRS)

    Schuerman, J. A.; Fischer, K. E.; Mclaughlin, P. W.

    1977-01-01

    A digital computer simulation of a mixed flow, twin spool turbofan engine was assembled to evaluate and improve the dynamic characteristics of the engine simulation to disturbance frequencies of at least 100 Hz. One dimensional forms of the dynamic mass, momentum and energy equations were used to model the engine. A TF30 engine was simulated so that dynamic characteristics could be evaluated against results obtained from testing of the TF30 engine at the NASA Lewis Research Center. Dynamic characteristics of the engine simulation were improved by modifying the compression system model. Modifications to the compression system model were established by investigating the influence of size and number of finite dynamic elements. Based on the results of this program, high frequency engine simulations using finite dynamic elements can be assembled so that the engine dynamic configuration is optimum with respect to dynamic characteristics and computer execution time. Resizing of the compression systems finite elements improved the dynamic characteristics of the engine simulation but showed that additional refinements are required to obtain close agreement simulation and actual engine dynamic characteristics.

  12. S1 screw bending moment with posterior spinal instrumentation across the lumbosacral junction after unilateral iliac crest harvest.

    PubMed

    Alegre, G M; Gupta, M C; Bay, B K; Smith, T S; Laubach, J E

    2001-09-15

    A biomechanical study comparing fixation across the lumbosacral junction. To determine which long posterior construct across the lumbosacral junction produces the least bending moment on the S1 screw when only one ilium is available for fixation. Recent in vitro studies have demonstrated the benefit of anterior support and fixation into the ilium when instrumenting a long posterior construct across the lumbosacral junction. Four L2-sacrum constructs were tested on six synthetic models of the lumbar spine and pelvis simulating that the right ilium had been harvested. Construct 1: L2-S1 bilateral screws. Construct 2: L2-S1 + left iliac bolt. Construct 3: L2-S1 + left iliac bolt + right S2 screw. Construct 4: L2-S1 + bilateral S2 screws. The four constructs were then retested with an anterior L5-S1 strut. A flexion-extension moment was applied across each construct, and the moment at the left and right S1 pedicle screw was measured with internal strain gauges. Iliac bolt fixation was found to significantly decrease the flexion-extension moment on the ipsilateral S1 screw by 70% and the contralateral screw by 26%. An anterior L5-S1 strut significantly decreased the S1 screw flexion-extension moment by 33%. Anterior support at L5-S1 provided no statistical decrease in the flexion-extension moment when bilateral posterior fixation beyond S1 was present with either a unilateral iliac bolt and contralateral S2 screw, or bilateral S2 screws. There is a significant decrease in the flexion-extension moment on the S1 screw when extending long posterior constructs to either the ilium or S2 sacral screw. There is no biomechanical advantage of the iliac bolt over the S2 screw in decreasing the moment on the S1 screw in flexion and extension. Adding anterior support to long posterior constructs significantly decreases the moment on the S1 screw. Adding distal posterior fixation to either the ilium or S2 decreases the moment on S1 screws more than adding anterior support. Further, adding anterior support when bilateral distal fixation past S1 is already present does not significantly decrease the moment on the S1 screws in flexion and extension.

  13. The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring - a retrospective review of 627 screws in 150 patients.

    PubMed

    Wood, Martin James; McMillen, Jason

    2014-01-01

    This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique.

  14. The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients

    PubMed Central

    McMillen, Jason

    2014-01-01

    Objective This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Methods Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Results Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. Conclusion The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. PMID:25694919

  15. Optimising implant anchorage (augmentation) during fixation of osteoporotic fractures: is there a role for bone-graft substitutes?

    PubMed

    Larsson, Sune; Procter, Philip

    2011-09-01

    When stabilising a fracture the contact between the screw and the surrounding bone is crucial for mechanical strength. Through development of screws with new thread designs, as well as optimisation of other properties, improved screw purchase has been gained. Other alternatives to improve screw fixation in osteoporotic bone, as well as normal bone if needed, includes the use of various coatings on the screw that will induce a bonding between the implant surface and the bone implant, as well as application of drugs such as bisphosphonates locally in the screw hole to induce improved screw anchorage through their anticatabolic effect on the bone tissue. As failure of internal fixation of fractures in osteoporotic bone typically occurs through breakage of the bone that surrounds the implant, rather than the implant itself, an alternative strategy in osteoporotic bone can include augmentation of the bone around the screw. This is useful when screws alone are being used for fixation, as it will increase pull-out resistance, but also when conventional plates and screws are used. In angularly stable plate-screw systems, screw back-out is not a problem if the locking mechanism between the screws and the plate works. However, augmentation that will strengthen the bone around the screws can also be useful in conjunction with angle-stable plate-screw systems, as the augmentation will provide valuable support when subjected to loading that might cause cut-out. For many years conventional bone cement, polymethylmethacrylate (PMMA), has been used for augmentation, but due to side effects--including great difficulties if removal becomes necessary--the use of PMMA has never gained wide acceptance. With the introduction of bone substitutes, such as calcium phosphate cement, it has been shown that augmentation around screws can be achieved without the drawbacks seen with PMMA. When dealing with fixation of fractures in osteoporotic bone where screw stability might be inadequate, it therefore seems an attractive option to include bone substitutes for augmentation around screws as part of the armamentarium. Clinical studies now are needed to determine the indications in which bone augmentation with bone-graft substitutes (BGSs) would merit clinical usage. Copyright © 2011. Published by Elsevier Ltd.

  16. Development of high-temperature Kolsky compression bar techniques for recrystallization investigation

    NASA Astrophysics Data System (ADS)

    Song, B.; Antoun, B. R.; Boston, M.

    2012-05-01

    We modified the design originally developed by Kuokkala's group to develop an automated high-temperature Kolsky compression bar for characterizing high-rate properties of 304L stainless steel at elevated temperatures. Additional features have been implemented to this high-temperature Kolsky compression bar for recrystallization investigation. The new features ensure a single loading on the specimen and precise time and temperature control for quenching to the specimen after dynamic loading. Dynamic compressive stress-strain curves of 304L stainless steel were obtained at 21, 204, 427, 649, and 871 °C (or 70, 400, 800, 1200, and 1600 °F) at the same constant strain rate of 332 s-1. The specimen subjected to specific time and temperature control for quenching after a single dynamic loading was preserved for investigating microstructure recrystallization.

  17. Fluid Compressibility Effects on the Dynamic Response of Hydrostatic Journal Bearings

    NASA Technical Reports Server (NTRS)

    Sanandres, Luis A.

    1991-01-01

    A theoretical analysis for the dynamic performance characteristics of laminar flow, capillar/orifice compensated hydrostatic journal bearings is presented. The analysis considers in detail the effect of fluid compressibility in the bearing recesses. At high frequency excitations beyond a break frequency, the bearing hydrostatic stiffness increases sharply and it is accompanied by a rapid decrease in direct damping. Also, the potential of pneumatic hammer instability (negative damping) at low frequencies is likely to occur in hydrostatic bearing applications handling highly compressible fluids. Useful design criteria to avoid undesirable dynamic operating conditions at low and high frequencies are determined. The effect of fluid recess compressibility is brought into perspective, and found to be of utmost importance on the entire frequency spectrum response and stability characteristics of hydrostatic/hybrid journal bearings.

  18. Inter- and intra-observer reliability of measurement of pedicle screw breach assessed by postoperative CT scans.

    PubMed

    Lavelle, William F; Ranade, Ashish; Samdani, Amer F; Gaughan, John P; D'Andrea, Linda P; Betz, Randal R

    2014-01-01

    Pedicle screws are used increasingly in spine surgery. Concerns of complications associated with screw breach necessitates accurate pedicle screw placement. Postoperative CT imaging helps to detect screw malposition and assess its severity. However, accuracy is dependent on the reading of the CT scans. Inter- and intra-observer variability could affect the reliability of CT scans to assess multiple screw types and sites. The purpose of this study was to assess the reliability of multi-observer analysis of CT scans for determining pedicle screw breach for various screw types and sites in patients with spinal deformity or degenerative pathologies. Axial CT scan images of 23 patients (286 screws) were read by four experienced spine surgeons. Pedicle screw placement was considered 'In' when the screw was fully contained and/or the pedicle wall breach was ≤2 mm. 'Out' was defined as a breach in the medial or lateral pedicle wall >2 mm. Intra-class coefficients (ICC) were calculated to assess the inter- and intra-observer reliability. Marked inter- and intra-observer variability was noticed. The overall inter-observer ICC was 0.45 (95% confidence limits 0.25 to 0.65). The intra-observer ICC was 0.49 (95% confidence limits 0.29 to 0.69). Underlying spinal pathology, screw type, and patient age did not seem to impact the reliability of our CT assessments. Our results indicate the evaluation of pedicle screw breach on CT by a single surgeon is highly variable, and care should be taken when using individual CT evaluations of millimeters of breach as a basis for screw removal. This was a Level III study.

  19. Experimental investigation of the fracture torque of orthodontic anchorage screws.

    PubMed

    Reimann, Susanne; Ayubi, Mustafa; McDonald, Fraser; Bourauel, Christoph

    2016-07-01

    In contrast to dental implants that remain in the bone, orthodontic anchorage screws serve as temporary anchorage for orthodontic tooth movement and are removed after completion of treatment. The aim of the present study was to evaluate the stability of various commercially available orthodontic anchorage screws against torsion. The torsional deflection of ten different orthodontic anchorage screws from different manufacturers [Ortho Easy Pin (Forestadent), Benefit, quattro (both PSM Medical Solutions), Vector TAS (Ormco), AbsoAnchor(®) (DENTOS Inc.), OrthoLox, Dual-Top JA (both Promedia Medizintechnik), TAD (3M Unitek), INFINITAS (ODS) and tomas(®) (Dentaurum)] was tested in vitro in relation to the rotation angle using a self-developed set-up. The screws were positioned in a resin model with bone-like material properties. Shear tests were performed using the manufacturers' own screwdrivers. Ten screws each were turned manually until a sudden drop in the measured torque occurred. At this point, the screw head was twisted off. Fracture torque and the torque at which the screws deformed plastically were evaluated. Mean values and standard deviations were calculated. According to the German industrial standard, the torque of orthodontic anchorage screws should reach at least 20 Ncm. The majority of the screws reached this nominal torque; however, a few screws fractured before reaching this value. Five screw types displayed plastic deformation below the threshold, at approximately 16 Ncm. The results suggest that orthodontic anchorage screws generally meet the requirements of the standard and ensure safe clinical use. However, according to the present data, it may be assumed that a portion of the screws will be plastically deformed upon removal.

  20. The effects of loading on the preload and dimensions of the abutment screw for a 3-unit cantilever-fixed prosthesis design.

    PubMed

    Setia, Gaurav; Yousef, Hoda; Ehrenberg, David; Luke, Allyn; Weiner, Saul

    2013-08-01

    The purpose of this study was to use an in vitro model system to compare the effects on the screw torque and screw dimensions within 2 commercially available implant systems from occlusal loading on a cantilevered-fixed partial denture. Cantilevered implant-supported 3-unit prostheses with 2 premolar abutments and 1 premolar pontic (7.3 mm in length) were made on resin casts containing 2 implant analogs for 2 implant systems: BioLok Silhouette Tapered Implant System (Birmingham, AL) and Zimmer Tapered Screw-Vent Implant System (Carlsbad, CA) with 10 samples in each group. Each sample was loaded with either of 2 protocols: (1) a load of 50 N on the cantilevered pontic unit and (2) a loading of 150 N on all 3 units. The outcome measures were (1) changes in residual torque of the abutment screws and (2) changes in screw dimension. The BioLok Silhouette Tapered Implant group demonstrated slight but statistically significant torque loss 18.8% to 28.5% in both abutment screws for both protocols, P ≤ 0.05, without any changes in screw dimension. In the Zimmer Tapered Screw-Vent Implant group, there was a significant elongation of the abutment screws and a markedly significant 44.4%, (P ≤ 0.01) loss in torque in the mesial screw and a 28.5%, (P ≤ 0.05) loss in torque in the distal screw when the cantilever alone was loaded. Differences in screw design influence the maintenance of preload and distortion of the shank. The influence of the interface design, namely an internal hex of 1 mm versus an external hex did not influence the preload. Cantilevered prostheses can cause loss of torque and dimensional changes in abutment screws.

  1. The applicability of PEEK-based abutment screws.

    PubMed

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Perforations and angulations of 324 cervical medial cortical pedicle screws: a possible guide to avoid lateral perforations with use of pedicle screws in lower cervical spine.

    PubMed

    Mahesh, Bijjawara; Upendra, Bidre; Vijay, Sekharappa; Arun, Kumar; Srinivasa, Reddy

    2017-03-01

    More than half of the perforations reported with usage of cervical pedicle screws (CPS) are lateral perforations, endangering the vertebral artery. The medial cortical pedicle screw (MCPS) technique with partial drilling of the medial cortex shifts the trajectory of pedicle screws medially, decreasing the lateral perforations. To evaluate the decrease in lateral perforations of CPS with use of MCPS technique, in relation to medial angulation. Retrospective analysis and technical report of the MCPS technique and its safety. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. Axial reconstructed computed tomography (CT) scan images of the inserted screws were evaluated for placement, perforations, and transverse plane angulations using the Surgimap software (Surgimap Spine 1.1.2.271 Intl. 2009 Nemaris LLC). The angulations of screws were analyzed by the type and level of placement through unpaired t test and analysis of variance test. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. There were 49 males and 9 females. Thirty-seven patients had cervical trauma, 17 had cervical spondylotic myelopathy, two had tumors, and two had ankylosing spondylitis. The average age was 49 years (range 18 to 80 years). The screws were inserted using the MCPS technique. All patients underwent postoperative CT scans with GE Optima CT540 16 slice CT scanner (GE Healthcare Chalfont St. Giles, Buckinghamshire, UK). Axial reconstructed images along the axis of the inserted screws were evaluated for placement and perforations. Further, all the screws were evaluated for transverse plane angulations using the Surgimap software. The angulations of screw were analyzed by the type and level of placement through unpaired t test and analysis of variance test. No funds were received by any of the authors for the purpose of the present study. A total of 324 screws were assessed with postoperative CT scans. Two hundred fifty-six were found to be placed within the pedicle and 68 (20.98%) screws were found to have perforations. Forty screws (12.34%) had grade I medial perforations, 14 screws (4.32%) had grade I lateral perforations, 10 screws (3.08%) had grade II medial perforations, and 4 screws (1.23%) had grade IIlateral perforations. The average angulation of the nonperforated screws (n=256) was 28.6° (43°-17°), that of laterally perforated screws was 20.33° (13°-24°), and that of the medially perforated screws was 34.94° (45°-20°). On statistical analysis with each series, the 99% CI range for the in-screw angles was 27.91° to 29.34°; for the laterally perforated screw series, it was 18.42° to 22.23°; and that for the medially perforated screw series was 32.97° to 36.9°. The MCPS technique represents a shift in the concept of placement of CPS from the cancellous core to the medial cortex, avoiding screw deflection laterally by the thick proximal medial cortex. The present study shows that the lateral perforations can be consistently avoided, with a medial angulation of more than 27.91°, which is the primary concern with the use of pedicle screws in lower cervical spine. Further, the MCPS technique reduces the lateral perforations at a lesser insertion angle, which is technically desirable. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Dynamic Compression of Chondrocyte-Agarose Constructs Reveals New Candidate Mechanosensitive Genes

    PubMed Central

    Bougault, Carole; Aubert-Foucher, Elisabeth; Paumier, Anne; Perrier-Groult, Emeline; Huot, Ludovic; Hot, David; Duterque-Coquillaud, Martine; Mallein-Gerin, Frédéric

    2012-01-01

    Articular cartilage is physiologically exposed to repeated loads. The mechanical properties of cartilage are due to its extracellular matrix, and homeostasis is maintained by the sole cell type found in cartilage, the chondrocyte. Although mechanical forces clearly control the functions of articular chondrocytes, the biochemical pathways that mediate cellular responses to mechanical stress have not been fully characterised. The aim of our study was to examine early molecular events triggered by dynamic compression in chondrocytes. We used an experimental system consisting of primary mouse chondrocytes embedded within an agarose hydrogel; embedded cells were pre-cultured for one week and subjected to short-term compression experiments. Using Western blots, we demonstrated that chondrocytes maintain a differentiated phenotype in this model system and reproduce typical chondrocyte-cartilage matrix interactions. We investigated the impact of dynamic compression on the phosphorylation state of signalling molecules and genome-wide gene expression. After 15 min of dynamic compression, we observed transient activation of ERK1/2 and p38 (members of the mitogen-activated protein kinase (MAPK) pathways) and Smad2/3 (members of the canonical transforming growth factor (TGF)-β pathways). A microarray analysis performed on chondrocytes compressed for 30 min revealed that only 20 transcripts were modulated more than 2-fold. A less conservative list of 325 modulated genes included genes related to the MAPK and TGF-β pathways and/or known to be mechanosensitive in other biological contexts. Of these candidate mechanosensitive genes, 85% were down-regulated. Down-regulation may therefore represent a general control mechanism for a rapid response to dynamic compression. Furthermore, modulation of transcripts corresponding to different aspects of cellular physiology was observed, such as non-coding RNAs or primary cilium. This study provides new insight into how chondrocytes respond to mechanical forces. PMID:22615857

  4. Evaluation of the use of intra-operative radiology for open placement of lag screws for the stabilization of sacroiliac luxation in cats.

    PubMed

    Silveira, Francisco; Quinn, Robert J; Adrian, Anna M; Owen, Martin R; Bush, Mark A

    2017-01-16

    To assess the effect of intra-operative radiology on the quality of lag screw insertion for the management of sacroiliac joint luxations in cats. In this retrospective single-centre study, the surgical, anaesthetic and imaging records of 40 screws (32 cats) placed with lag effect for management of sacroiliac luxation were reviewed. Postoperative radiographs were assessed for sacroiliac joint reduction, screw position, and sacral width purchased by each screw. Cases were divided into two groups according to the use of (IOR) or the absence of intra-operative radiology (NIOR). A total of 23 lag screws were placed with the aid of intra-operative radiology and 17 without. Three of the 23 screws placed in the IOR group exited the sacrum as opposed to eight of 17 screws in the NIOR group (p = 0.03). Mean sacral width purchased by the screws in the IOR group (70.8%) was also significantly higher (p = 0.002) than in the NIOR group (54.6%). Mean general anaesthetic times for unilateral and bilateral screw placement for the IOR group and NIOR group were not significantly different. The use of intra-operative radiology can significantly improve the quality of lag screw insertion for the stabilization of sacroiliac luxations in cats, which should lead to a reduced incidence of postoperative screw loosening.

  5. Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

    PubMed Central

    Kim, Seok-Gyu; Son, Mee-Kyoung

    2015-01-01

    PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening. PMID:26140172

  6. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    PubMed

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  7. A novel electromagnetic navigation tool for acetabular surgery.

    PubMed

    Lehmann, Wolfgang; Rueger, Johannes M; Nuechtern, Jakob; Grossterlinden, Lars; Kammal, Michael; Hoffmann, Michael

    2015-10-01

    Acetabular fracture surgery is demanding and screw placement along narrow bony corridors remains challenging. It necessitates x-ray radiation for fluoroscopically assisted screw insertion. The purpose of this cadaver study was to evaluate the feasibility, accuracy and operation time of a novel electromagnetic navigation system for screw insertion along predefined acetabular corridors. A controlled laboratory study with a total of 24 electromagnetically navigated screw insertions was performed on 8 cadaveric acetabula. 3 peri-acetabular bony corridors (QSS, Quadrilateral Surface Screw; IAS, Infra-Acetabular Screw; PCS, Posterior Column Screw) were defined and screws were placed in a defined order without fluoroscopy. Operation time was documented. Postoperative CT scans were performed to analyse accuracy of screw placement. Mean cadaver age was 70.4 ± 11.7. Successful screw placement was accomplished in 22 out of 24 (91.7%) cases. The overall mean time for all 3 acetabular screws was 576.6 ± 75.9s. All 3 complications occurred during the placement of the IAS due to an impassable narrow bony corridor. QSS mean length was 50 ± 5mm, IAS mean length was 85 ± 10mm and PCS mean length was 120 ± 5mm. In this cadaver study the novel electromagnetic navigation system was feasible to allow accurate screw placement without fluoroscopy in defined narrow peri-acetabular bony corridors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Use of C2 spinous process screw for posterior cervical fixation as substitute for laminar screw in a patient with thin laminae

    PubMed Central

    Nagata, Kosei; Baba, Satoshi; Chikuda, Hirotaka; Takeshita, Katsushi

    2013-01-01

    Rigid screw fixation of C2 including transarticular screw and pedicle screw contain the risk of vertebral artery (VA) injury. On the other hand, translaminar screws are considered to be safer for patients with anomalous VA. But C2 translaminar screw placement was limited in patients who have thin laminas and there is marked variation in C2 laminar thickness. Appropriate C2 fixation method for a patient who has thin laminas and high-riding VA together was controversial. Here, we present a case of an elderly Asian woman who had thin laminas and high-riding VA together with progressive myelopathy to report a first case of C2 spinous process screw insertion. Although the stability and safety of C2 spinous process screw was reported in cadaver series, there was no clinical report to our knowledge. Spinous process screw can be an option of C2 fixation for patients with high-riding VA and severe degenerated cervical spines including thin C2 laminas. PMID:23814004

  9. Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring.

    PubMed

    Huang, Shao-Fu; Chen, Wan-Rung; Lin, Chun-Li

    2016-02-24

    This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown.

  10. The pattern of xylan acetylation suggests xylan may interact with cellulose microfibrils as a twofold helical screw in the secondary plant cell wall of Arabidopsis thaliana

    PubMed Central

    Busse-Wicher, Marta; Gomes, Thiago C F; Tryfona, Theodora; Nikolovski, Nino; Stott, Katherine; Grantham, Nicholas J; Bolam, David N; Skaf, Munir S; Dupree, Paul

    2014-01-01

    The interaction between xylan and cellulose microfibrils is important for secondary cell wall properties in vascular plants; however, the molecular arrangement of xylan in the cell wall and the nature of the molecular bonding between the polysaccharides are unknown. In dicots, the xylan backbone of β-(1,4)-linked xylosyl residues is decorated by occasional glucuronic acid, and approximately one-half of the xylosyl residues are O-acetylated at C-2 or C-3. We recently proposed that the even, periodic spacing of GlcA residues in the major domain of dicot xylan might allow the xylan backbone to fold as a twofold helical screw to facilitate alignment along, and stable interaction with, cellulose fibrils; however, such an interaction might be adversely impacted by random acetylation of the xylan backbone. Here, we investigated the arrangement of acetyl residues in Arabidopsis xylan using mass spectrometry and NMR. Alternate xylosyl residues along the backbone are acetylated. Using molecular dynamics simulation, we found that a twofold helical screw conformation of xylan is stable in interactions with both hydrophilic and hydrophobic cellulose faces. Tight docking of xylan on the hydrophilic faces is feasible only for xylan decorated on alternate residues and folded as a twofold helical screw. The findings suggest an explanation for the importance of acetylation for xylan–cellulose interactions, and also have implications for our understanding of cell wall molecular architecture and properties, and biological degradation by pathogens and fungi. They will also impact strategies to improve lignocellulose processing for biorefining and bioenergy. PMID:24889696

  11. Finite Strain Behavior of Polyurea for a Wide Range of Strain Rates

    DTIC Science & Technology

    2010-02-01

    dimensional dynamic compressive behavior of EPDM rubber ," Journal of Engineering Materials and Technology, Transaction of the ASME, 125:294-301. [97] Song, B...and Chen, W. (2004) "Dynamic compressive behavior of EPDM rubber un- der nearly uniaxial strain conditions," Journal of Engineering Materials and... rubber elastic springs to describe the steep initial stiffness of virgin butadiene rubber under tensile and compressive loading at intermediate strain

  12. Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study.

    PubMed

    Andrews, Boyd J; Fallat, Lawrence M; Kish, John P

    2016-01-01

    The chevron osteotomy is a popular procedure used for the correction of moderate hallux abducto valgus deformity. Fixation is typically accomplished with Kirschner wires or bone screws; however, in cystic or osteoporotic bone, these could be inadequate, resulting in displacement of the capital fragment. We propose using a locking plate and interfragmental screw for fixation of the chevron osteotomy that could reduce the healing time and decrease the incidence of displacement. We performed a retrospective cohort study for chevron osteotomies on 75 feet (73 patients). The control groups underwent fixation with 1 screw in 30 feet (40%) and 2 screws in 30 feet (40%). A total of 15 feet (20%) were included in the locking plate and interfragmental screw group. The patients were followed up until bone healing was achieved at a median of 7 (range 6 to 14) weeks. Our hypothesis was that those treated with the locking plate and interfragmental screw would have a faster healing time and fewer incidents of capital fragment displacement compared with the 1- or 2-screw groups. The corresponding mean intervals to healing for the 1-screw group was 7.71 ± 1.28 (range 6 to 10) weeks, for the 2-screw group was 7.27 ± 1.57 (range 6 to 14) weeks, and for the locking plate and interfragmental screw group was 7.01 ± 1.00 (range 6 to 9) weeks. One case of capital fragment displacement occurred in the single screw group and one in the 2-screw group. No displacement occurred in the locking plate and interfragmental screw group. Neither finding was statistically significant. However, we believe the locking plate and interfragmental screw could be a viable option in patients with osteoporotic and cystic bone changes for correction of hallux abducto valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

    PubMed

    Macke, Jeremy J; Woo, Raymund; Varich, Laura

    2016-06-01

    This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.

  14. Radiographic predictors of symptomatic screw removal after retrograde femoral nail insertion.

    PubMed

    Hamaker, Max; O'Hara, Nathan N; Eglseder, W Andrew; Sciadini, Marcus F; Nascone, Jason W; O'Toole, Robert V

    2017-03-01

    Removal of symptomatic implants is a common procedure performed by orthopaedic trauma surgeons. No guidance is available regarding which factors contribute to the likelihood of an implant becoming symptomatic. Our objective was to determine whether radiographic parameters associated with distal interlocks in retrograde femoral nails are associated with the rate of symptomatic screw removal. We conducted a retrospective review at a Level I trauma center. Study patients (n=442) had femoral fractures treated with retrograde intramedullary nails from 2007 to 2014 and at least 1year of follow-up. The main outcome measurement was symptomatic distal screw removal as predicted by radiographic parameters. Symptomatic screw removal occurred in 12% of the patients. Increased distance between the most distal screw and the articular surface of the femur significantly reduced likelihood of symptomatic screw removal. A cutoff of 40mm from the articular block was predictive of removal (≥40mm, 0% removal; <40mm, 18% removal, p<0.0001). In patients with distal screws placed within 40mm of the articular surface of the femur, a ratio of screw length to distance between medial and lateral femoral cortices that was ≥1 was a strong predictor of symptomatic screw removal (area under Receiver Operating Characteristic curve, 0.75; p<0.0001). More distal screws and screws that radiographically extend to or beyond the medial cortex are more likely to cause pain and require removal in femoral fractures treated with retrograde intramedullary nails. We identified a specific distance from the joint (<40mm) and a ratio of screw length to bone width (≥1) that significantly increased the likelihood of symptomatic screw removal. Clinicians can use these data to inform patients of the likely risk of implant removal and perhaps to better guide placement and length of screws when the clinical scenario allows some flexibility in location and length of screws. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws.

    PubMed

    Lapsiwala, Samir B; Anderson, Paul A; Oza, Ashish; Resnick, Daniel K

    2006-03-01

    We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.

  16. Design of internal screw thread measuring device based on the Three-Line method principle

    NASA Astrophysics Data System (ADS)

    Hu, Dachao; Chen, Jianguo

    2010-08-01

    In accordance with the principle of Three-Line, this paper analyze the correlation of every main parameter of internal screw thread, and then designed a device to measure the main parameters of internal screw thread. Internal thread parameters, such as the pitch diameter, thread angle and screw-pitch of common screw thread, terraced screw thread, zigzag screw thread were obtained through calculation and measurement. The practical applications have proved that this device is convenience to use, and the measurements have a high accuracy. Meanwhile, the application for the patent of invention has been accepted by the Patent Office (Filing number: 200710044081.5).

  17. Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex.

    PubMed

    Wentaschek, Stefan; Tomalla, Sven; Schmidtmann, Irene; Lehmann, Karl Martin

    To examine the screw preload, coefficient of friction (COF), and tightening torque needed to overcome the thread friction of an implant-abutment-screw complex. In a customized load frame, 25 new implant-abutment-screw complexes including uncoated titanium alloy screws were torqued and untorqued 10 times each, applying 25 Ncm. Mean preload values decreased significantly from 209.8 N to 129.5 N according to the number of repetitions. The overall COF increased correspondingly. There was no comparable trend for the thread friction component. These results suggest that the application of a used implant-abutment-screw complex may be unfavorable for obtaining optimal screw preload.

  18. A Reduced Order Model of Force Displacement Curves for the Failure of Mechanical Bolts in Tension.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Keegan J.; Sandia National Lab.; Brake, Matthew Robert

    2015-12-01

    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry causes issues when generating a mesh of the model. This report will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. Themore » results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.« less

  19. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    PubMed

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p<.05) and significantly decreased work energy to failure (p<.05). Nearly half (n=7) of the pedicle screws had failed during the reduction attempt with visible pullout of the screw. After reduction, decreased POS was observed in both normal (p<.05) and osteoporotic (p<.05) bone. Back out and reinsertion of the screw resulted in no significant difference in mean POS, stiffness, and work energy to failure (p>.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright failure. Further rod contouring or correction of pedicle screw depth of insertion may be warranted to allow for appropriate alignment of the longitudinal rods. Published by Elsevier Inc.

  20. Reverse shoulder arthroplasty glenoid fixation: is there a benefit in using four instead of two screws?

    PubMed

    James, Jaison; Allison, Mari A; Werner, Frederick W; McBride, Devin E; Basu, Niladri N; Sutton, Levi G; Nanavati, Vipul N

    2013-08-01

    To allow osseous integration to occur and thus provide long-term stability, initial glenoid baseplate fixation must be sufficiently rigid. A major contributing factor to initial rigid fixation is baseplate screw fixation. Current baseplate designs use a 4-screw fixation construct. However, recent literature suggests adequate fixation can be achieved with fewer than 4 screws. The purpose of the present study was to determine whether a 4-screw construct provides more baseplate stability than a 2-screw construct. A flat-backed glenoid baseplate with 4 screw hole options was implanted into 6 matched pairs of cadaver scapulas using standard surgical technique. Within each pair, 2 screws or 4 screws were implanted in a randomized fashion. A glenosphere was attached allowing cyclic loading in an inferior-to-superior direction and in an anterior-to-posterior direction. Baseplate motion was measured using 4 linear voltage displacement transducers evenly spaced around the glenosphere. There was no statistical difference in the average peak central displacements between fixation with 2 or 4 screws (P = .338). Statistical increases in average peak central displacement with increasing load (P < .001) and with repetitive loading (P < .002) were found. This study demonstrates no statistical difference in baseplate motion between 2-screw and 4-screw constructs. Therefore, using fewer screws could potentially lead to a reduction in operative time, cost, and risk, with no significant negative effect on overall implant baseplate motion. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Top