Sample records for dynamic enclosure method

  1. Explosion hazards of LPG-air mixtures in vented enclosure with obstacles.

    PubMed

    Zhang, Qi; Wang, Yaxing; Lian, Zhen

    2017-07-15

    Numerical simulations were performed to study explosion characteristics of liquefied petroleum gas (LPG) explosion in enclosure with a vent. Unlike explosion overpressure and dynamic pressure, explosion temperature of the LPG-air mixture at a given concentration in a vented enclosure has very little variation with obstacle numbers for a given blockage ratio. For an enclosure without obstacle, explosion overpressures for the stoichiometric mixtures and the fuel-lean mixtures reach their maximum within the vent and that for fuel-rich mixture reaches its maximum beyond and near the vent. Dynamic pressures produced by an indoor LPG explosion reach their maximum always beyond the vent no matter obstacles are present or not in the enclosure. A LPG explosion in a vented enclosure with built-in obstacles is strong enough to make the brick and mortar wall with a thickness of 370mm damaged. If there is no obstacle in the enclosure, the lower explosion pressure of several kPa can not break the brick and mortar wall with a thickness of 370mm. For a LPG explosion produced in an enclosure with a vent, main hazards, within the vent, are overpressure and high temperature. However main hazards are dynamic pressure, blast wind, and high temperature beyond the vent. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Rigorous high-precision enclosures of fixed points and their invariant manifolds

    NASA Astrophysics Data System (ADS)

    Wittig, Alexander N.

    The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by Johannes Grote is extended to compute very accurate polynomial approximations to invariant manifolds of discrete maps of arbitrary dimension around hyperbolic fixed points. The algorithm presented allows for automatic removal of resonances occurring during construction. A method for the rigorous enclosure of invariant manifolds of continuous systems is introduced. Using methods developed for discrete maps, polynomial approximations of invariant manifolds of hyperbolic fixed points of ODEs are obtained. These approximations are outfit with a sharp error bound which is verified to rigorously contain the manifolds. While we focus on the three dimensional case, verification in higher dimensions is possible using similar techniques. Integrating the resulting enclosures using the verified COSY VI integrator, the initial manifold enclosures are expanded to yield sharp enclosures of large parts of the stable and unstable manifolds. To demonstrate the effectiveness of this method, we construct enclosures of the invariant manifolds of the Lorenz system and show pictures of the resulting manifold enclosures. To the best of our knowledge, these enclosures are the largest verified enclosures of manifolds in the Lorenz system in existence.

  3. Computational fluid dynamics modeling and analysis for the Giant Magellan Telescope (GMT)

    NASA Astrophysics Data System (ADS)

    Ladd, John; Slotnick, Jeffrey; Norby, William; Bigelow, Bruce; Burgett, William

    2016-08-01

    The Giant Magellan Telescope (GMT) is planned for construction at a summit of Cerro Las Campanas at the Los Campanas Observatory (LCO) in Chile. GMT will be the most powerful ground-based telescope in operation in the world. Aero-thermal interactions between the site topography, enclosure, internal systems, and optics are complex. A key parameter for optical quality is the thermal gradient between the terrain and the air entering the enclosure, and how quickly that gradient can be dissipated to equilibrium. To ensure the highest quality optical performance, careful design of the telescope enclosure building, location of the enclosure on the summit, and proper venting of the airflow within the enclosure is essential to minimize the impact of velocity and temperature gradients in the air entering the enclosure. High-fidelity Reynolds-Averaged Navier Stokes (RANS) Computational Fluid Dynamics (CFD) analysis of the GMT, enclosure, and LCO terrain is performed to study (a) the impact of either an open or closed enclosure base soffit external shape design, (b) the effect of telescope/enclosure location on the mountain summit, and (c) the effect of enclosure venting patterns. Details on the geometry modeling, grid discretization, and flow solution are first described. Then selected computational results are shown to quantify the quality of the airflow entering the GMT enclosure based on soffit, site location, and venting considerations. Based on the results, conclusions are provided on GMT soffit design, site location, and enclosure venting. The current work is not used to estimate image quality but will be addressed in future analyses as described in the conclusions.

  4. Bifurcation Analysis Using Rigorous Branch and Bound Methods

    NASA Technical Reports Server (NTRS)

    Smith, Andrew P.; Crespo, Luis G.; Munoz, Cesar A.; Lowenberg, Mark H.

    2014-01-01

    For the study of nonlinear dynamic systems, it is important to locate the equilibria and bifurcations occurring within a specified computational domain. This paper proposes a new approach for solving these problems and compares it to the numerical continuation method. The new approach is based upon branch and bound and utilizes rigorous enclosure techniques to yield outer bounding sets of both the equilibrium and local bifurcation manifolds. These sets, which comprise the union of hyper-rectangles, can be made to be as tight as desired. Sufficient conditions for the existence of equilibrium and bifurcation points taking the form of algebraic inequality constraints in the state-parameter space are used to calculate their enclosures directly. The enclosures for the bifurcation sets can be computed independently of the equilibrium manifold, and are guaranteed to contain all solutions within the computational domain. A further advantage of this method is the ability to compute a near-maximally sized hyper-rectangle of high dimension centered at a fixed parameter-state point whose elements are guaranteed to exclude all bifurcation points. This hyper-rectangle, which requires a global description of the bifurcation manifold within the computational domain, cannot be obtained otherwise. A test case, based on the dynamics of a UAV subject to uncertain center of gravity location, is used to illustrate the efficacy of the method by comparing it with numerical continuation and to evaluate its computational complexity.

  5. Influence of Structural Flexibility on the Dynamic Precision of a Vehicle-Mounted Equipment System

    DTIC Science & Technology

    2015-05-12

    Paramsothy Jayakumar , Dave Mechergui, Ronald Renke U.S.Army RDECOM TARDEC INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A...COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A VEHICLE-MOUNTED EQUIPMENT...Equipment Enclosure CMS Results 23 12. Influence of CMS Method on the Vehicle Dynamics 24 13. Influence of Flexibility on the Vehicle

  6. Dynamic response of a modified water tank exposed to concentrated solar energy

    NASA Astrophysics Data System (ADS)

    Alhamdo, M. H.; Alkhakani, A. J.

    2017-08-01

    Power generation by using concentrated solar thermal energy on liquid enclosures is one of the most promising renewable energy technologies. In this work, a developed liquid enclosure fitted with various number and configurations of horizontal metal rings have been analyzed, fabricated and tested. The influence of adding metal rings arrangement is investigated for its potential to enhance radial heat conduction to the center-line of the enclosure from the side-walls. Experiments were carried out for fluid in both static and dynamic modes of operation inside the enclosure that subjected to high heat flux. A developed two-dimensional CFD model to predict the transient flow and thermal fields within liquid enclosure subjected to heat flux has been developed and tested. The developed numerical model takes into consideration energy transport between the liquid inside enclosure and the solid material of the enclosure. The numerical simulations have been compared with experimental measurement. The computational code has been found in a good level of agreement with the experimental data except for liquid at the peak part of the enclosure. The results indicate that adding metal rings produce significant impact on the transient temperature difference inside enclosure during both static and dynamic modes. The six-ring model is found to be more effective for enhancing radial heat transfer than other three models that have been tested. The in-line arrangement is found to provide better thermal effect as compared to the staggered rings. Two new correlations for natural heat transfer inside liquid enclosures subjected to high heat flux have been formulated (one for no-ring model and the other for six-ring model). The natural Nusselt number is found to be around a constant value for Rayleigh number less than (5 X 108). The recommended use of metal rings inside liquid enclosures subjected to heat flux, and the predicted Nusselt number correlation, will add to local knowledge a significant mean to gain more heat in large scale concentrated solar power plants. Two new correlations for natural heat transfer inside liquid enclosures subjected to high heat flux have been formulated (one for no-ring model and the other for six-ring model). The natural Nusselt number is found to be around a constant value for Rayleigh number less than (5 X 108). The recommended use of metal rings inside liquid enclosures subjected to heat flux, and the predicted Nusselt number correlation, will add to local knowledge a significant mean to gain more heat in large scale concentrated solar power plants.

  7. Methods and apparatus for measuring the tightness of enclosures

    DOEpatents

    Modera, Mark P.; Sherman, Max H.

    1987-01-13

    Disclosed are methods and apparatus for measuring tightness of an enclosure such as a building by utilizing alternating pressurization techniques. One method comprises providing apparatus capable of causing an internal volume change for the enclosure, the apparatus including a means for determining the instantaneous volume change, and a means for determining the instantaneous pressure within the enclosure. The apparatus is operated within the enclosure to change the volume thereof, and at least one of the frequency and the displacement is adjusted to achieve a root mean square pressure in the enclosure approximately equal to a reference pressure. At that pressure, the leakage of the enclosure is determined from the instantaneous displacement and instantaneous pressure values.

  8. Methods and apparatus for measuring the tightness of enclosures

    DOEpatents

    Modera, M.P.; Sherman, M.H.

    1987-01-13

    Disclosed are methods and apparatus for measuring tightness of an enclosure such as a building by utilizing alternating pressurization techniques. One method comprises providing apparatus capable of causing an internal volume change for the enclosure, the apparatus including a means for determining the instantaneous volume change, and a means for determining the instantaneous pressure within the enclosure. The apparatus is operated within the enclosure to change the volume thereof, and at least one of the frequency and the displacement is adjusted to achieve a root mean square pressure in the enclosure approximately equal to a reference pressure. At that pressure, the leakage of the enclosure is determined from the instantaneous displacement and instantaneous pressure values. 3 figs.

  9. 30 CFR 77.701-2 - Approved methods of grounding metallic frames, casings, and other enclosures of electric...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... enclosures and the earth. (b) A method of grounding of metallic frames, casings, and other enclosures of... there is no difference in potential between such frames, casings, and other enclosures, and the earth. ...

  10. Effect of flow rate on environmental variables and phytoplankton dynamics: results from field enclosures

    NASA Astrophysics Data System (ADS)

    Zhang, Haiping; Chen, Ruihong; Li, Feipeng; Chen, Ling

    2015-03-01

    To investigate the effects of flow rate on phytoplankton dynamics and related environment variables, a set of enclosure experiments with different flow rates were conducted in an artificial lake. We monitored nutrients, temperature, dissolved oxygen, pH, conductivity, turbidity, chlorophyll- a and phytoplankton levels. The lower biomass in all flowing enclosures showed that flow rate significantly inhibited the growth of phytoplankton. A critical flow rate occurred near 0.06 m/s, which was the lowest relative inhibitory rate. Changes in flow conditions affected algal competition for light, resulting in a dramatic shift in phytoplankton composition, from blue-green algae in still waters to green algae in flowing conditions. These findings indicate that critical flow rate can be useful in developing methods to reduce algal bloom occurrence. However, flow rate significantly enhanced the inter-relationships among environmental variables, in particular by inducing higher water turbidity and vegetative reproduction of periphyton ( Spirogyra). These changes were accompanied by a decrease in underwater light intensity, which consequently inhibited the photosynthetic intensity of phytoplankton. These results warn that a universal critical flow rate might not exist, because the effect of flow rate on phytoplankton is interlinked with many other environmental variables.

  11. 46 CFR 28.370 - Wiring methods and materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Boat or UL Marine Shipboard cable; or (iii) Meet 46 CFR part 111, subpart 111.60. (e) All metallic... enclosure such as a junction box, fixture enclosure, or panel enclosure. A fire retardant plastic enclosure...

  12. Automated enclosure and protection system for compact solar-tracking spectrometers

    NASA Astrophysics Data System (ADS)

    Heinle, Ludwig; Chen, Jia

    2018-04-01

    A novel automated enclosure for protecting solar-tracking atmospheric instruments was designed, constructed, and successfully tested under various weather conditions. A complete automated measurement system, consisting of a compact solar-tracking Fourier transform infrared (FTIR) spectrometer (EM27/SUN) and the enclosure, has been deployed in central Munich to monitor greenhouse gases since 2016 and withstood all critical weather conditions, including rain, storms, and snow. It provided ground-based measurements of column-averaged concentrations of CO2, CH4, O2, and H2O throughout this time.The enclosure protects the instrument from harmful environmental influences while allowing open-path measurements in sunny weather. The newly developed and patented cover, a key component of the enclosure, permits unblocked solar measurements while reliably protecting the instrument. This enables dynamic decision regarding taking measurements, and thus increases the number of data samples. This enclosure leads to a fully automated measurement system, which collects data whenever possible without any human interaction. In the long term, the enclosure will provide the foundation for a permanent greenhouse gas monitoring sensor network.

  13. Method for sealing remote leaks in an enclosure using an aerosol

    DOEpatents

    Modera, Mark P.; Carrie, Francois R.

    1999-01-01

    The invention is a method and device for sealing leaks remotely by means of injecting a previously prepared aerosol into the enclosure being sealed according to a particular sealing efficiency defined by the product of a penetration efficiency and a particle deposition efficiency. By using different limits in the relationship between penetration efficiency and flowrate, the same method according the invention can be used for coating the inside of an enclosure. Specifically the invention is a method and device for preparing, transporting, and depositing a solid phase aerosol to the interior surface of the enclosure relating particle size, particle carrier flow rate, and pressure differential, so that particles deposited there can bridge and substantially seal each leak, with out providing a substantial coating at inside surfaces of the enclosure other than the leak. The particle size and flow parameters can be adjusted to coat the interior of the enclosure (duct) without substantial plugging of the leaks depending on how the particle size and flowrate relationships are chosen.

  14. A simple formula for insertion loss prediction of large acoustical enclosures using statistical energy analysis method

    NASA Astrophysics Data System (ADS)

    Kim, Hyun-Sil; Kim, Jae-Seung; Lee, Seong-Hyun; Seo, Yun-Ho

    2014-12-01

    Insertion loss prediction of large acoustical enclosures using Statistical Energy Analysis (SEA) method is presented. The SEA model consists of three elements: sound field inside the enclosure, vibration energy of the enclosure panel, and sound field outside the enclosure. It is assumed that the space surrounding the enclosure is sufficiently large so that there is no energy flow from the outside to the wall panel or to air cavity inside the enclosure. The comparison of the predicted insertion loss to the measured data for typical large acoustical enclosures shows good agreements. It is found that if the critical frequency of the wall panel falls above the frequency region of interest, insertion loss is dominated by the sound transmission loss of the wall panel and averaged sound absorption coefficient inside the enclosure. However, if the critical frequency of the wall panel falls into the frequency region of interest, acoustic power from the sound radiation by the wall panel must be added to the acoustic power from transmission through the panel.

  15. Dynamic tester for rotor seals and bearings

    NASA Technical Reports Server (NTRS)

    Vonpragenau, George L. (Inventor)

    1993-01-01

    A dynamic tester for testing vibration damping seals and bearings is constructed having a hollow shaft extending through the seal or bearing, with the shaft internally supported at each end by fluid bearings on hollow bosses connected to an interior of an enclosure, with no rolling members connected to the shaft is described. A high pressure working fluid is forced through the hollow bosses to operate the bearings. Additionally, the shaft is provided with a reaction turbine that angularly vents a portion of the high pressure working fluid in order to rotate the shaft at high speed, up to 40,000 rpm. The seal or bearing is mounted in a bushing, in turn supported by rods to a shaking device that vibrates the seal or bearing as the shaft is rotated. A plurality of proximity sensors are mounted from outside the enclosure to sense shaft and seal bushing vibrations, and a plurality of pressure ports are disposed in the enclosure to allow sensing of dynamic and static pressures of the testing apparatus.

  16. New modeling method and mechanism analyses for active control of interior noise in an irregular enclosure using piezoelectric actuators.

    PubMed

    Geng, Hou C; Rao, Zhu S; Han, Zu S

    2003-03-01

    A new modeling method is developed in this paper for the active minimization of noise within a three-dimensional irregular enclosure using distributed lead zirconate titanate piezoelectric (PZT) actuators, and the control mechanisms for irregular enclosure are analyzed. The irregular enclosure is modeled with four rigid walls and two simply supported flexible panels, and PZT actuators are bound to one of the flexible panels. The process of the new modeling method is as follows. First, the modal coupling method is used to establish the motion equations, which contain important coefficients such as modal masses and modal coupling coefficients, etc., of acoustic-structural-piezoelectric coupling system. Then, the acoustic modes and the modal masses of irregular enclosure are calculated by numerical methods. Last, the modal coupling coefficients in motion equations are calculated according to the numerical results of the acoustic modes of irregular enclosure and the modes of two panels. The validity of this modeling method is verified by a regular hexahedron enclosure. Two cost functions are applied to this model. With the two cost functions, good results are obtained in minimizing the sound-pressure level (SPL) within irregular enclosure according to numerical investigations. By comparing the results obtained under controlled and uncontrolled states, the control mechanisms of the system are discussed. It is found that the control mechanisms vary with disturbance frequencies. At most disturbance frequencies, the SPL within enclosure is reduced by restructuring the modes of two panels simultaneously. When the disturbance frequency comes close to one of the natural frequencies of panel a, the dominant mode of panel a is suppressed, while the modes of panel b are reconstructed. While the disturbance frequency is near one of the natural frequencies of panel b, the modes of two panels are restructured at the same time.

  17. Evacuate and backfill apparatus and method

    DOEpatents

    Oakley, David J.; Groves, Oliver J.

    1985-01-01

    An apparatus and method for treatment of hollow articles by evacuating existing gas or gases therefrom and purging or backfilling the articles with a second gas such as helium. The apparatus includes a sealed enclosure having an article storage drum mounted therein. A multiplicity of such articles are fed singly into the enclosure and loaded into radial slots formed in the drum. The enclosure is successively evacuated and purged with helium to replace the existing gas in the articles with helium. The purged articles are then discharged singly from the drum and transported out of the enclosure.

  18. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces.

    PubMed

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-12-08

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions.

  19. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces

    PubMed Central

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-01-01

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions. PMID:29292781

  20. Diode-laser-pump module with integrated signal ports for pumping amplifying fibers and method

    DOEpatents

    Savage-Leuchs,; Matthias, P [Woodinville, WA

    2009-05-26

    Apparatus and method for collimating pump light of a first wavelength from laser diode(s) into a collimated beam within an enclosure having first and second optical ports, directing pump light from the collimated beam to the first port; and directing signal light inside the enclosure between the first and second port. The signal and pump wavelengths are different. The enclosure provides a pump block having a first port that emits pump light to a gain fiber outside the enclosure and that also passes signal light either into or out of the enclosure, and another port that passes signal light either out of or into the enclosure. Some embodiments use a dichroic mirror to direct pump light to the first port and direct signal light between the first and second ports. Some embodiments include a wavelength-conversion device to change the wavelength of at least some of the signal light.

  1. Husbandry and enclosure influences on penguin behavior and conservation breeding.

    PubMed

    Marshall, Andrew R; Deere, Nicolas J; Little, Holly A; Snipp, Ross; Goulder, Jackie; Mayer-Clarke, Stacey

    2016-09-01

    Multi-zoo comparisons of animal welfare are rare, and yet vital for ensuring continued improvement of zoo enclosures and husbandry. Methods are not standardized for the development of zoo enclosures based on multiple indicators, and case study species are required. This study compares behavior and breeding success to various enclosure and husbandry parameters for the Humboldt penguin, Spheniscus humboldti, for the development of improved enclosure design. Behavioral sampling was completed at Flamingo Land over a period of 8 months. Further data on behavior, enclosure design, and breeding success were collected via questionnaires, visits to zoos, and literature review. Breeding success was primarily influenced by colony age and number of breeding pairs, suggesting an important social influence on reproduction. Across zoos, there was also significant variation in behavior. The proportion of time spent in water varied between zoos (2-23%) and was used as an indicator of physical activity and natural behavior. Regression models revealed that water-use was best predicted by total enclosure area per penguin, followed by land area, with some evidence for positive influence of pool surface area per penguin. Predominantly linear/curvilinear increases in our biological indicators with enclosure parameters suggest that optimal conditions for S. humboldti were not met among the selected zoos. We propose revised minimum conditions for S. humboldti enclosure design, which exceed those in the existing husbandry guidelines. We present a framework for the evaluation of zoo enclosures and suggest that a rigorous scientific protocol be established for the design of new enclosures, based on multivariate methods. Zoo Biol. 35:385-397, 2016. © Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Virtual sensors for active noise control in acoustic-structural coupled enclosures using structural sensing: robust virtual sensor design.

    PubMed

    Halim, Dunant; Cheng, Li; Su, Zhongqing

    2011-03-01

    The work was aimed to develop a robust virtual sensing design methodology for sensing and active control applications of vibro-acoustic systems. The proposed virtual sensor was designed to estimate a broadband acoustic interior sound pressure using structural sensors, with robustness against certain dynamic uncertainties occurring in an acoustic-structural coupled enclosure. A convex combination of Kalman sub-filters was used during the design, accommodating different sets of perturbed dynamic model of the vibro-acoustic enclosure. A minimax optimization problem was set up to determine an optimal convex combination of Kalman sub-filters, ensuring an optimal worst-case virtual sensing performance. The virtual sensing and active noise control performance was numerically investigated on a rectangular panel-cavity system. It was demonstrated that the proposed virtual sensor could accurately estimate the interior sound pressure, particularly the one dominated by cavity-controlled modes, by using a structural sensor. With such a virtual sensing technique, effective active noise control performance was also obtained even for the worst-case dynamics. © 2011 Acoustical Society of America

  3. Shielded multi-stage EMI noise filter

    DOEpatents

    Kisner, Roger Allen; Fugate, David Lee

    2016-11-08

    Electromagnetic interference (EMI) noise filter embodiments and methods for filtering are provided herein. EMI noise filters include multiple signal exclusion enclosures. The multiple signal exclusion enclosures contain filter circuit stages. The signal exclusion enclosures can attenuate noise generated external to the enclosures and/or isolate noise currents generated by the corresponding filter circuits within the enclosures. In certain embodiments, an output of one filter circuit stage is connected to an input of the next filter circuit stage. The multiple signal exclusion enclosures can be chambers formed using conductive partitions to divide an outer signal exclusion enclosure. EMI noise filters can also include mechanisms to maintain the components of the filter circuit stages at a consistent temperature. For example, a metal base plate can distribute heat among filter components, and an insulating material can be positioned inside signal exclusion enclosures.

  4. Analysis of sound absorption performance of an electroacoustic absorber using a vented enclosure

    NASA Astrophysics Data System (ADS)

    Cho, Youngeun; Wang, Semyung; Hyun, Jaeyub; Oh, Seungjae; Goo, Seongyeol

    2018-03-01

    The sound absorption performance of an electroacoustic absorber (EA) is primarily influenced by the dynamic characteristics of the loudspeaker that acts as the actuator of the EA system. Therefore, the sound absorption performance of the EA is maximum at the resonance frequency of the loudspeaker and tends to degrade in the low-frequency and high-frequency bands based on this resonance frequency. In this study, to adjust the sound absorption performance of the EA system in the low-frequency band of approximately 20-80 Hz, an EA system using a vented enclosure that has previously been used to enhance the radiating sound pressure of a loudspeaker in the low-frequency band, is proposed. To verify the usefulness of the proposed system, two acoustic environments are considered. In the first acoustic environment, the vent of the vented enclosure is connected to an external sound field that is distinct from the sound field coupled to the EA. In this case, the acoustic effect of the vented enclosure on the performance of the EA is analyzed through an analytical approach using dynamic equations and an impedance-based equivalent circuit. Then, it is verified through numerical and experimental approaches. Next, in the second acoustic environment, the vent is connected to the same external sound field as the EA. In this case, the effect of the vented enclosure on the EA is investigated through an analytical approach and finally verified through a numerical approach. As a result, it is confirmed that the characteristics of the sound absorption performances of the proposed EA system using the vented enclosure in the two acoustic environments considered in this study are different from each other in the low-frequency band of approximately 20-80 Hz. Furthermore, several case studies on the change tendency of the performance of the EA using the vented enclosure according to the critical design factors or vent number for the vented enclosure are also investigated. In the future, even if the proposed EA system using a vented enclosure is extended to a large number of arrays required for 3D sound field control, it is expected to be an attractive solution that can contribute to an improvement in low-frequency noise reduction without causing economic and system complexity problems.

  5. Evacuate and backfill apparatus and method

    DOEpatents

    Oakley, D.J.; Groves, O.J.

    1984-06-27

    An apparatus and method as described for treatment of hollow articles by evacuating existing gas or gases therefrom and purging or backfilling the articles with a second gas such as helium. The apparatus includes a sealed enclosure having an article storage drum mounted therein. A multiplicity of such articles are fed singly into the enclosure and loaded into radial slots formed in the drum. The enclosure is successively evacuated and purged with helium to replace the existing gas in the articles with helium. The purged articles are then discharged singly from the drum and transported out of the enclosure.

  6. Optimization of Sensing and Feedback Control for Vibration/Flutter of Rotating Disk by PZT Actuators via Air Coupled Pressure

    PubMed Central

    Yan, Tianhong; Xu, Xinsheng; Han, Jianqiang; Lin, Rongming; Ju, Bingfeng; Li, Qing

    2011-01-01

    In this paper, a feedback control mechanism and its optimization for rotating disk vibration/flutter via changes of air-coupled pressure generated using piezoelectric patch actuators are studied. A thin disk rotates in an enclosure, which is equipped with a feedback control loop consisting of a micro-sensor, a signal processor, a power amplifier, and several piezoelectric (PZT) actuator patches distributed on the cover of the enclosure. The actuator patches are mounted on the inner or the outer surfaces of the enclosure to produce necessary control force required through the airflow around the disk. The control mechanism for rotating disk flutter using enclosure surfaces bonded with sensors and piezoelectric actuators is thoroughly studied through analytical simulations. The sensor output is used to determine the amount of input to the actuator for controlling the response of the disk in a closed loop configuration. The dynamic stability of the disk-enclosure system, together with the feedback control loop, is analyzed as a complex eigenvalue problem, which is solved using Galerkin’s discretization procedure. The results show that the disk flutter can be reduced effectively with proper configurations of the control gain and the phase shift through the actuations of PZT patches. The effectiveness of different feedback control methods in altering system characteristics and system response has been investigated. The control capability, in terms of control gain, phase shift, and especially the physical configuration of actuator patches, are also evaluated by calculating the complex eigenvalues and the maximum displacement produced by the actuators. To achieve a optimal control performance, sizes, positions and shapes of PZT patches used need to be optimized and such optimization has been achieved through numerical simulations. PMID:22163788

  7. Optimization of sensing and feedback control for vibration/flutter of rotating disk by PZT actuators via air coupled pressure.

    PubMed

    Yan, Tianhong; Xu, Xinsheng; Han, Jianqiang; Lin, Rongming; Ju, Bingfeng; Li, Qing

    2011-01-01

    In this paper, a feedback control mechanism and its optimization for rotating disk vibration/flutter via changes of air-coupled pressure generated using piezoelectric patch actuators are studied. A thin disk rotates in an enclosure, which is equipped with a feedback control loop consisting of a micro-sensor, a signal processor, a power amplifier, and several piezoelectric (PZT) actuator patches distributed on the cover of the enclosure. The actuator patches are mounted on the inner or the outer surfaces of the enclosure to produce necessary control force required through the airflow around the disk. The control mechanism for rotating disk flutter using enclosure surfaces bonded with sensors and piezoelectric actuators is thoroughly studied through analytical simulations. The sensor output is used to determine the amount of input to the actuator for controlling the response of the disk in a closed loop configuration. The dynamic stability of the disk-enclosure system, together with the feedback control loop, is analyzed as a complex eigenvalue problem, which is solved using Galerkin's discretization procedure. The results show that the disk flutter can be reduced effectively with proper configurations of the control gain and the phase shift through the actuations of PZT patches. The effectiveness of different feedback control methods in altering system characteristics and system response has been investigated. The control capability, in terms of control gain, phase shift, and especially the physical configuration of actuator patches, are also evaluated by calculating the complex eigenvalues and the maximum displacement produced by the actuators. To achieve a optimal control performance, sizes, positions and shapes of PZT patches used need to be optimized and such optimization has been achieved through numerical simulations.

  8. Preparation System and Method

    NASA Technical Reports Server (NTRS)

    Zhang, Ye (Inventor); Wu, Honglu (Inventor)

    2015-01-01

    Systems and methods for preparing a sample for further analysis are provided. The system can include an enclosure. A membrane can be disposed within the enclosure. First and second reservoirs can be disposed within the enclosure, and at least one of the first and second reservoirs can be adapted to have a reagent disposed therein. A valve can be disposed within the enclosure and in fluid communication with the first or second reservoirs or both. The valve can also be in fluid communication with the membrane. The valve can be adapted to selectively regulate the flow of the reagent from the first reservoir, through the membrane, and into the second reservoir.

  9. Resource loading system and method for use in atmosphere-containment scenarios

    DOEpatents

    Dilday, Jr., Daniel R.; Reyes, Roberto; Weidmeyer, Stanley

    2017-09-12

    The invention provides a system for preventing fluid exchange between the interior and exterior of containment enclosures such as process-, hazard-, and research-enclosure systems generally, gloveboxes, containment systems, isolation systems, confinement systems, cleanrooms, negative air systems, and positive air system areas while simultaneously providing material transfer into and out of the enclosures. The invention also provides a method for transporting material into or out of a containment structure.

  10. 40 CFR 63.4765 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., substitute TVH for each occurrence of the term volatile organic compounds (VOC) in the methods. (3) Use... building enclosure. During the capture efficiency measurement, all organic compound emitting operations... enclosure is a building enclosure. During the capture efficiency measurement, all organic compound emitting...

  11. 40 CFR 63.4765 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., substitute TVH for each occurrence of the term volatile organic compounds (VOC) in the methods. (3) Use... building enclosure. During the capture efficiency measurement, all organic compound emitting operations... enclosure is a building enclosure. During the capture efficiency measurement, all organic compound emitting...

  12. Method and apparatus for producing high purity silicon

    DOEpatents

    Olson, Jerry M.

    1984-01-01

    A method for producing high purity silicon includes forming a copper silie alloy and positioning the alloy within an enclosure. A filament member is also placed within the enclosure opposite the alloy. The enclosure is then filled with a chemical vapor transport gas adapted for transporting silicon. Finally, both the filament member and the alloy are heated to temperatures sufficient to cause the gas to react with silicon at the alloy surface and deposit the reacted silicon on the filament member. In addition, an apparatus for carrying out this method is also disclosed.

  13. Method and apparatus for producing high purity silicon

    DOEpatents

    Olson, J.M.

    1983-05-27

    A method for producing high purity silicon includes forming a copper silicide alloy and positioning the alloy within an enclosure. A filament member is also placed within the enclosure opposite the alloy. The enclosure is then filled with a chemical vapor transport gas adapted for transporting silicon. Finally, both the filament member and the alloy are heated to temperatures sufficient to cause the gas to react with silicon at the alloy surface and deposit the reacted silicon on the filament member. In addition, an apparatus for carrying out this method is also disclosed.

  14. Methods of Making Z-Shielding

    NASA Technical Reports Server (NTRS)

    Thomsen, III, Donald Laurence (Inventor); Cano, Roberto J. (Inventor); Jensen, Brian J. (Inventor); Hales, Stephen J. (Inventor); Alexa, Joel A. (Inventor)

    2014-01-01

    Methods of building Z-graded radiation shielding and covers. In one aspect, the method includes: providing a substrate surface having about medium Z-grade; plasma spraying a first metal having higher Z-grade than the substrate surface; and infusing a polymer layer to form a laminate. In another aspect, the method includes electro/electroless plating a first metal having higher Z-grade than the substrate surface. In other aspects, the methods include improving an existing electronics enclosure to build a Z-graded radiation shield by applying a temperature controller to at least part of the enclosure and affixing at least one layer of a first metal having higher Z-grade from the enclosure.

  15. Cold plate with combined inclined impingement and ribbed channels

    DOEpatents

    Parida, Pritish R.

    2015-12-22

    Heat transfer devices and methods for making the same that include a first enclosure having at least one inlet port; a second enclosure having a bottom plate and one or more dividing walls to establish channels, at least one internal surface of each channel having rib structures to create turbulence in a fluid flow; and a jet plate connecting the first enclosure and the second enclosure having impinging jets that convey fluid from the first enclosure to the channels, said impinging jets being set at an angular deviation from normal to cause local acceleration of fluid and to increase a local heat transfer rate.

  16. Emissions of biogenic sulfur gases from northern bogs and fens

    NASA Technical Reports Server (NTRS)

    Demello, William Zamboni; Hines, Mark E.; Bayley, Suzanne E.

    1992-01-01

    Sulfur gases are important components of the global cycle of S. They contribute to the acidity of precipitation and they influence global radiation balance and climate. The role of terrestrial sources of biogenic S and their effect on atmospheric chemistry remain as major unanswered questions in our understanding of the natural S cycle. The role of northern wetlands as sources and sinks of gaseous S by measuring rates of S gas exchange as a function of season, hydrologic conditions, and gradients in tropic status was investigated. Experiments were conducted in wetlands in New Hampshire, particularly a poor fen, and in Mire 239, a poor fen at the Experimental Lakes Area (ELA) in Ontario. Emissions were determined using Teflon enclosures, gas cryotrapping methods and gas chromatography (GC) with flame photometric detection. Dynamic (sweep flow) and static enclosures were employed which yielded similar results. Dissolved S gases and methane were determined by gas stripping followed by GC.

  17. Risks incurred by hydrogen escaping from containers and conduits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swain, M.R.; Grilliot, E.S.

    1998-08-01

    This paper is a discussion of a method for hydrogen leak classification. Leaks are classified as; gas escapes into enclosed spaces, gas escapes into partially enclosed spaces (vented), and gas escapes into unenclosed spaces. Each of the three enclosure classifications is further divided into two subclasses; total volume of hydrogen escaped and flow rate of escaping hydrogen. A method to aid in risk assessment determination in partially enclosed spaces is proposed and verified for several enclosure geometries. Examples are discussed for additional enclosure geometries.

  18. 30 CFR 77.701-2 - Approved methods of grounding metallic frames, casings, and other enclosures of electric...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... from a direct-current power system with one polarity grounded will be approved: (1) A solid connection..., casings, and other enclosures of electric equipment receiving power from a direct-current power system. 77... enclosures of electric equipment receiving power from a direct-current power system. (a) The following...

  19. 30 CFR 77.701-2 - Approved methods of grounding metallic frames, casings, and other enclosures of electric...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... from a direct-current power system with one polarity grounded will be approved: (1) A solid connection..., casings, and other enclosures of electric equipment receiving power from a direct-current power system. 77... enclosures of electric equipment receiving power from a direct-current power system. (a) The following...

  20. Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 1: Dynamic models and computer simulations for the ERBE nonscanner, scanner and solar monitor sensors

    NASA Technical Reports Server (NTRS)

    Halyo, Nesim; Choi, Sang H.; Chrisman, Dan A., Jr.; Samms, Richard W.

    1987-01-01

    Dynamic models and computer simulations were developed for the radiometric sensors utilized in the Earth Radiation Budget Experiment (ERBE). The models were developed to understand performance, improve measurement accuracy by updating model parameters and provide the constants needed for the count conversion algorithms. Model simulations were compared with the sensor's actual responses demonstrated in the ground and inflight calibrations. The models consider thermal and radiative exchange effects, surface specularity, spectral dependence of a filter, radiative interactions among an enclosure's nodes, partial specular and diffuse enclosure surface characteristics and steady-state and transient sensor responses. Relatively few sensor nodes were chosen for the models since there is an accuracy tradeoff between increasing the number of nodes and approximating parameters such as the sensor's size, material properties, geometry, and enclosure surface characteristics. Given that the temperature gradients within a node and between nodes are small enough, approximating with only a few nodes does not jeopardize the accuracy required to perform the parameter estimates and error analyses.

  1. Method and device for producing and delivering an aerosol for remote sealing and coating

    DOEpatents

    Modera, M.P.; Carrie, F.R.

    1996-06-04

    The invention is a method and device for sealing leaks remotely by means of injecting a previously prepared aerosol into the enclosure being sealed. Specifically the invention is a method and device for preparing, transporting, and depositing and solid phase aerosol to the interior surface of the enclosure. 1 fig.

  2. 30 CFR 75.701-2 - Approved method of grounding metallic frames, casings and other enclosures receiving power from...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved method of grounding metallic frames... grounding metallic frames, casings and other enclosures receiving power from single-phase 110-220-volt... only method of grounding that will be approved is the connection of all metallic frames, casings and...

  3. Productivity of a coral reef using boundary layer and enclosure methods

    USGS Publications Warehouse

    McGillis, W.R.; Langdon, C.; Loose, B.; Yates, K.K.; Corredor, Jorge

    2011-01-01

    The metabolism of Cayo Enrique Reef, Puerto Rico, was studied using in situ methods during March 2009. Benthic O2 fluxes were used to calculate net community production using both the boundary layer gradient and enclosure techniques. The boundary layer O2 gradient and the drag coefficients were used to calculate productivity ranging from -12.3 to 13.7 mmol O2 m-2 h-1. Productivity measurements from the enclosure method ranged from -11.0 to 12.9 mmol O2 m-2 h-1. During the study, the mean hourly difference between the methods was 0.65 mmol O2 m-2 h-1 (r2 = 0.92), resulting in well-reconciled estimates of net community production between the boundary layer (-33.1 mmol m-2 d-1) and enclosure (-46.3 mmol m-2 d-1) techniques. The results of these independent approaches corroborate quantified rates of metabolism at Cayo Enrique Reef. Close agreement between methods demonstrates that boundary layer measurements can provide near real-time assessments of coral reef health.

  4. Productivity of a coral reef using boundary layer and enclosure methods

    USGS Publications Warehouse

    McGillis, W.R.; Langdon, C.; Loose, B.; Yates, K.K.; Corredor, J.

    2011-01-01

    The metabolism of Cayo Enrique Reef, Puerto Rico, was studied using in situ methods during March 2009. Benthic O2 fluxes were used to calculate net community production using both the boundary layer gradient and enclosure techniques. The boundary layer O2 gradient and the drag coefficients were used to calculate productivity ranging from -12.3 to 13.7 mmol O 2 m-2 h-1. Productivity measurements from the enclosure method ranged from -11.0 to 12.9 mmol O2 m-2 h-1. During the study, the mean hourly difference between the methods was 0.65 mmol O2 m-2 h-1 (r2 = 0.92), resulting in well-reconciled estimates of net community production between the boundary layer (-33.1 mmol m-2 d-1) and enclosure (-46.3 mmol m-2 d-1) techniques. The results of these independent approaches corroborate quantified rates of metabolism at Cayo Enrique Reef. Close agreement between methods demonstrates that boundary layer measurements can provide near real-time assessments of coral reef health. Copyright ?? 2011 by the American Geophysical Union.

  5. Effects of stream enclosures on drifting invertebrates and fish growth

    USGS Publications Warehouse

    Zimmerman, J.K.H.; Vondracek, B.

    2006-01-01

    Stream ecologists often use enclosure experiments to investigate predator-prey interactions and competition within and among fish species. The design of enclosures, manipulation of species densities, and method of replication may influence experimental results. We designed an experiment with enclosure cages (1 m2, 6-mm mesh) to examine the relative influence of fish size, density, and prey availability on growth of brown trout (Salmo trutta), brook trout (Salvelinus fontinalis), and slimy sculpin (Cottus cognatus) within enclosures in Valley Creek, Minnesota. In addition, we examined water flow and invertebrate drift entering enclosures and in open riffles to investigate whether enclosures reduced the supply of invertebrate prey. Growth of small (age-0) brook and brown trout was not influenced by fish density, but growth of larger (age-1) trout generally decreased as density increased. Sculpin growth was not related to fish size or density, but increased with mean size of invertebrates in the drift. Enclosures reduced water flow and tended to reduce invertebrate drift rate, although total drift rate (ind./min), total drift density (ind./m3), and mean size of invertebrates were not significantly different inside enclosures compared to adjacent stream riffles. Enclosures had no effect on drift rate or size of Gammarus pseudolimnaeus, the main prey item for trout and sculpin in Valley Creek. Overall, our analyses indicated that reductions of prey availability by enclosures did not influence fish growth. Trout growth may have been limited at larger sizes and densities because of increased activity costs of establishing and defending territories, whereas sculpin growth was related to availability of large prey, a factor not influenced by enclosures. ?? 2006 by The North American Benthological Society.

  6. Adhesive coated electrical apparatus having sublimable protective covering and an assembly method

    DOEpatents

    Wootton, Roy E.

    1982-01-01

    Electrical apparatus including an enclosure, an electrode disposed within the enclosure, and supports for insulatably supporting the electrode within the enclosure has a permanently sticky adhesive material which is disposed on the interior surface of the outer enclosure. A high-vapor-pressure sublimable material is disposed on the permanently sticky adhesive material, with the sublimable material capable of subliming away in the presence of a vacuum. The presence of the sublimable material enables the apparatus to be non-sticky during assembly and handling operations, while being rendered sticky upon commissioning of the apparatus.

  7. Ventilation for an enclosure of a gas turbine and related method

    DOEpatents

    Schroeder, Troy Joseph; Leach, David; O'Toole, Michael Anthony

    2002-01-01

    A ventilation scheme for a rotary machine supported on pedestals within an enclosure having a roof, end walls and side walls with the machine arranged parallel to the side walls, includes ventilation air inlets located in a first end wall of the enclosure; a barrier wall located within the enclosure, proximate the first end wall to thereby create a plenum chamber. The barrier wall is constructed to provide a substantially annular gap between the barrier wall and a casing of the turbine to thereby direct ventilation air axially along the turbine; one or more ventilation air outlets located proximate a second, opposite end wall on the roof of the enclosure. In addition, one or more fans are provided for pulling ventilating air into said plenum chamber via the ventilation air inlets.

  8. Modeling and Simulation of the Transient Response of Temperature and Relative Humidity Sensors with and without Protective Housing

    PubMed Central

    Rocha, Keller Sullivan Oliveira; Martins, José Helvecio; Martins, Marcio Arêdes; Ferreira Tinôco, Ilda de Fátima; Saraz, Jairo Alexander Osorio; Filho, Adílio Flauzino Lacerda; Fernandes, Luiz Henrique Martins

    2014-01-01

    Based on the necessity for enclosure protection of temperature and relative humidity sensors installed in a hostile environment, a wind tunnel was used to quantify the time that the sensors take to reach equilibrium in the environmental conditions to which they are exposed. Two treatments were used: (1) sensors with polyvinyl chloride (PVC) enclosure protection, and (2) sensors with no enclosure protection. The primary objective of this study was to develop and validate a 3-D computational fluid dynamics (CFD) model for analyzing the temperature and relative humidity distribution in a wind tunnel using sensors with PVC enclosure protection and sensors with no enclosure protection. A CFD simulation model was developed to describe the temperature distribution and the physics of mass transfer related to the airflow relative humidity. The first results demonstrate the applicability of the simulation. For verification, a sensor device was successfully assembled and tested in an environment that was optimized to ensure fast change conditions. The quantification setup presented in this paper is thus considered to be adequate for testing different materials and morphologies for enclosure protection. The results show that the boundary layer flow regime has a significant impact on the heat flux distribution. The results indicate that the CFD technique is a powerful tool which provides a detailed description of the flow and temperature fields as well as the time that the relative humidity takes to reach equilibrium with the environment in which the sensors are inserted. PMID:24851994

  9. Investigation of the validity of radiosity for sound-field prediction in cubic rooms

    NASA Astrophysics Data System (ADS)

    Nosal, Eva-Marie; Hodgson, Murray; Ashdown, Ian

    2004-12-01

    This paper explores acoustical (or time-dependent) radiosity using predictions made in four cubic enclosures. The methods and algorithms used are those presented in a previous paper by the same authors [Nosal, Hodgson, and Ashdown, J. Acoust. Soc. Am. 116(2), 970-980 (2004)]. First, the algorithm, methods, and conditions for convergence are investigated by comparison of numerous predictions for the four cubic enclosures. Here, variables and parameters used in the predictions are varied to explore the effect of absorption distribution, the necessary conditions for convergence of the numerical solution to the analytical solution, form-factor prediction methods, and the computational requirements. The predictions are also used to investigate the effect of absorption distribution on sound fields in cubic enclosures with diffusely reflecting boundaries. Acoustical radiosity is then compared to predictions made in the four enclosures by a ray-tracing model that can account for diffuse reflection. Comparisons are made of echograms, room-acoustical parameters, and discretized echograms. .

  10. Investigation of the validity of radiosity for sound-field prediction in cubic rooms.

    PubMed

    Nosal, Eva-Marie; Hodgson, Murray; Ashdown, Ian

    2004-12-01

    This paper explores acoustical (or time-dependent) radiosity using predictions made in four cubic enclosures. The methods and algorithms used are those presented in a previous paper by the same authors [Nosal, Hodgson, and Ashdown, J. Acoust. Soc. Am. 116(2), 970-980 (2004)]. First, the algorithm, methods, and conditions for convergence are investigated by comparison of numerous predictions for the four cubic enclosures. Here, variables and parameters used in the predictions are varied to explore the effect of absorption distribution, the necessary conditions for convergence of the numerical solution to the analytical solution, form-factor prediction methods, and the computational requirements. The predictions are also used to investigate the effect of absorption distribution on sound fields in cubic enclosures with diffusely reflecting boundaries. Acoustical radiosity is then compared to predictions made in the four enclosures by a ray-tracing model that can account for diffuse reflection. Comparisons are made of echograms, room-acoustical parameters, and discretized echograms.

  11. Sulfur gas exchange in Sphagnum-dominated wetlands

    NASA Technical Reports Server (NTRS)

    Hines, Mark E.; Demello, William Zamboni; Porter, Carolyn A.

    1992-01-01

    Sulfur gases are important components of the global cycle of S. They contribute to the acidity of precipitation and they influence global radiation balance and climate. The role of terrestrial sources of biogenic S and their effect on atmospheric chemistry remain as major unanswered questions in our understanding of the natural S cycle. The role of northern wetlands as sources and sinks of gaseous S was investigated by measuring rates of S gas exchange as a function of season, hydrologic conditions, and gradients in trophic status. The effects of inorganic S input on the production and emission of gaseous S were also investigated. Experiments were conducted in wetlands in New Hampshire, particularly a poor fen, fens within the Experimental Lakes Area (ELA) in Ontario, Canada and in freshwater and marine tundra. Emissions were determined using Teflon enclosures, gas cryotrapping methods, and gas chromatography (GC) with flame photometric detection. Dynamic (sweep flow) and static enclosures were employed. Dissolved gases were determined by gas stripping followed by GC.

  12. Totally confined explosive welding. [apparatus to reduce noise level and protect personnel during explosive bonding

    NASA Technical Reports Server (NTRS)

    Bement, L. J. (Inventor)

    1974-01-01

    A method and associated apparatus for confining the undesirable by-products and limiting noise of explosive welding are discussed. The apparatus consists fo a simple enclosure into which the explosive is placed and within which the explosion occurs. The shape of the enclosure, the placement of the explosive, and the manner in which the enclosure is placed upon the material to be welded determine the force of the explosion transmitted to the proposed bond area. The explosion is totally confined within the enclosure thus reducing the noise level and preventing debris from being strewn about to contaminate the weld area or create personnel hazards.

  13. Effects of Whole-Ecosystem Warming on Porewater Chemistry and Hydrology in a Northern Peatland

    NASA Astrophysics Data System (ADS)

    Griffiths, N.; Sebestyen, S. D.

    2016-12-01

    Northern peatlands are carbon-rich ecosystems, and thus it is important to understand the effects of climate change on carbon cycle feedbacks in these vulnerable systems. An ecosystem-scale experiment is evaluating the effects of warming and elevated CO2 on an ombrotrophic bog in northern Minnesota, USA. Ten enclosures, each 12-m in diameter, were constructed in the peatland to allow for both above and belowground warming. Each enclosure receives one of five temperature treatments (+0 to +9°C), with half of the enclosures receiving elevated CO2 (+500ppm) and the other half ambient CO2. A belowground corral with a lateral drainage system surrounds each enclosure, and allows for measurements of lateral outflow volume and chemistry. Piezometers are used to sample porewater chemistry at different depths (0-3m) into the peat. We evaluated the effects of one year of whole-ecosystem warming on depth-specific porewater chemistry and outflow dynamics. Changes in porewater chemistry were observed upon initiation of whole-ecosystem warming. Total organic carbon (TOC) concentrations increased in near-surface porewater in the warmer enclosures, while concentrations were lower and similar to pre-treatment conditions in the ambient (+0°C) enclosures. The changes in TOC concentration measured in response to whole-ecosystem warming were initially limited to only the near-surface porewater (0 m); however, TOC concentrations began to increase at 0.3 m depth after several months of warming. These changes in TOC concentrations were also reflected in water draining from each enclosure, with generally higher TOC concentrations in water flowing from warmer enclosures. However, warmer treatments tended to have lower water outflow rates, possibly due to increased evapotranspiration, and thus TOC fluxes were generally lowest from the warmest enclosures. Overall, these initial results suggest that warming may increase porewater TOC concentrations, possibly due to increased mineralization rates of peat; however, due to the interaction with hydrology, export of this TOC to downstream ecosystems may be lower with warming. Continued measurements over the next 10 years will evaluate the long-term effects of warming on peatland chemistry and hydrology.

  14. Systems and Methods for RFID-Enabled Pressure Sensing Apparatus

    NASA Technical Reports Server (NTRS)

    Kennedy, Timothy F. (Inventor); Lin, Gregory Y. (Inventor); Ngo, Phong H. (Inventor); Fink, Patrick W. (Inventor)

    2017-01-01

    Methods, apparatuses and systems for radio frequency identification (RFID)-enabled information collection are disclosed, including an enclosure, a collector coupled to the enclosure, an interrogator, a processor, and one or more RFID field sensors, each having an individual identification, disposed within the enclosure. In operation, the interrogator transmits an incident signal to the collector, causing the collector to generate an electromagnetic field within the enclosure. The electromagnetic field is affected by one or more influences. RFID sensors respond to the electromagnetic field by transmitting reflected signals containing the individual identifications of the responding RFID sensors to the interrogator. The interrogator receives the reflected signals, measures one or more returned signal strength indications ("RSSI") of the reflected signals and sends the RSSI measurements and identification of the responding RFID sensors to the processor to determine one or more facts about the influences. Other embodiments are also described.

  15. Systems and Methods for RFID-Enabled Dispenser

    NASA Technical Reports Server (NTRS)

    Fink, Patrick W. (Inventor); Kennedy, Timothy F. (Inventor); Lin, Gregory Y. (Inventor); Ngo, Phong H. (Inventor); Byerly, Diane (Inventor)

    2015-01-01

    Methods, apparatuses and systems for radio frequency identification (RFID)-enabled information collection are disclosed, including an enclosure, a collector coupled to the enclosure, an interrogator, a processor, and one or more RFID field sensors, each having an individual identification, disposed within the enclosure. In operation, the interrogator transmits an incident signal to the collector, causing the collector to generate an electromagnetic field within the enclosure. The electromagnetic field is affected by one or more influences. RFID sensors respond to the electromagnetic field by transmitting reflected signals containing the individual identifications of the responding RFID sensors to the interrogator. The interrogator receives the reflected signals, measures one or more returned signal strength indications ("RSSI") of the reflected signals and sends the RSSI measurements and identification of the responding RFID sensors to the processor to determine one or more facts about the influences. Other embodiments are also described.

  16. Systems and Methods for RFID-Enabled Pressure Sensing Apparatus

    NASA Technical Reports Server (NTRS)

    Lin, Gregory Y. (Inventor); Ngo, Phong H. (Inventor); Kennedy, Timothy F. (Inventor); Fink, Patrick W. (Inventor)

    2016-01-01

    Methods, apparatuses and systems for radio frequency identification (RFID)-enabled information collection are disclosed, including an enclosure, a collector coupled to the enclosure, an interrogator, a processor, and one or more RFID field sensors, each having an individual identification, disposed within the enclosure. In operation, the interrogator transmits an incident signal to the collector, causing the collector to generate an electromagnetic field within the enclosure. The electromagnetic field is affected by one or more influences. RFID sensors respond to the electromagnetic field by transmitting reflected signals containing the individual identifications of the responding RFID sensors to the interrogator. The interrogator receives the reflected signals, measures one or more returned signal strength indications ("RSSI") of the reflected signals and sends the RSSI measurements and identification of the responding RFID sensors to the processor to determine one or more facts about the influences. Other embodiments are also described.

  17. System and Method for RFID-Enabled Information Collection

    NASA Technical Reports Server (NTRS)

    Fink, Patrick W. (Inventor); Kennedy, Timothy F. (Inventor); Lin, Gregory Y. (Inventor); Ngo, Phong H. (Inventor); Byerly, Diane (Inventor)

    2016-01-01

    Methods, apparatuses and systems for radio frequency identification (RFID)-enabled information collection are disclosed, including an enclosure, a collector coupled to the enclosure, an interrogator, a processor, and one or more RFID field sensors, each having an individual identification, disposed within the enclosure. In operation, the interrogator transmits an incident signal to the collector, causing the collector to generate an electromagnetic field within the enclosure. The electromagnetic field is affected by one or more influences. RFID sensors respond to the electromagnetic field by transmitting reflected signals containing the individual identifications of the responding RFID sensors to the interrogator. The interrogator receives the reflected signals, measures one or more returned signal strength indications ("RSSI") of the reflected signals and sends the RSSI measurements and identification of the responding RFID sensors to the processor to determine one or more facts about the influences. Other embodiments are also described.

  18. Modular, security enclosure and method of assembly

    DOEpatents

    Linker, Kevin L.; Moyer, John W.

    1995-01-01

    A transportable, reusable rapidly assembled and disassembled, resizable modular, security enclosure utilizes a stepped panel construction. Each panel has an inner portion and an outer portion which form joints. A plurality of channels can be affixed to selected joints of the panels. Panels can be affixed to a base member and then affixed to one another by the use of elongated pins extending through the channel joints. Alternatively, the base member can be omitted and the panels themselves can be used as the floor of the enclosure. The pins will extend generally parallel to the joint in which they are located. These elongated pins are readily inserted into and removable from the channels in a predetermined sequence to allow assembly and disassembly of the enclosure. A door constructed from panels is used to close the opening to the enclosure.

  19. Population density and seasonality effects on Sin Nombre virus transmission in North American deermice (Peromyscus maniculatus) in outdoor enclosures.

    PubMed

    Bagamian, Karoun H; Douglass, Richard J; Alvarado, Arlene; Kuenzi, Amy J; Amman, Brian R; Waller, Lance A; Mills, James N

    2012-01-01

    Surveys of wildlife host-pathogen systems often document clear seasonal variation in transmission; conclusions concerning the relationship between host population density and transmission vary. In the field, effects of seasonality and population density on natural disease cycles are challenging to measure independently, but laboratory experiments may poorly reflect what happens in nature. Outdoor manipulative experiments are an alternative that controls for some variables in a relatively natural environment. Using outdoor enclosures, we tested effects of North American deermouse (Peromyscus maniculatus) population density and season on transmission dynamics of Sin Nombre hantavirus. In early summer, mid-summer, late summer, and fall 2007-2008, predetermined numbers of infected and uninfected adult wild deermice were released into enclosures and trapped weekly or bi-weekly. We documented 18 transmission events and observed significant seasonal effects on transmission, wounding frequency, and host breeding condition. Apparent differences in transmission incidence or wounding frequency between high- and low-density treatments were not statistically significant. However, high host density was associated with a lower proportion of males with scrotal testes. Seasonality may have a stronger influence on disease transmission dynamics than host population density, and density effects cannot be considered independent of seasonality.

  20. 30 CFR 75.701-3 - Approved methods of grounding metallic frames, casings and other enclosures of electric equipment...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., casings and other enclosures of electric equipment receiving power from direct current power systems with... equipment receiving power from direct current power systems with one polarity grounded. For the purpose of... direct-current power system with one polarity grounded, the following methods of grounding will be...

  1. 30 CFR 75.701-3 - Approved methods of grounding metallic frames, casings and other enclosures of electric equipment...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., casings and other enclosures of electric equipment receiving power from direct current power systems with... equipment receiving power from direct current power systems with one polarity grounded. For the purpose of... direct-current power system with one polarity grounded, the following methods of grounding will be...

  2. 30 CFR 75.701-3 - Approved methods of grounding metallic frames, casings and other enclosures of electric equipment...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., casings and other enclosures of electric equipment receiving power from direct current power systems with... equipment receiving power from direct current power systems with one polarity grounded. For the purpose of... direct-current power system with one polarity grounded, the following methods of grounding will be...

  3. 30 CFR 75.701-3 - Approved methods of grounding metallic frames, casings and other enclosures of electric equipment...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., casings and other enclosures of electric equipment receiving power from direct current power systems with... equipment receiving power from direct current power systems with one polarity grounded. For the purpose of... direct-current power system with one polarity grounded, the following methods of grounding will be...

  4. 30 CFR 75.701-3 - Approved methods of grounding metallic frames, casings and other enclosures of electric equipment...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., casings and other enclosures of electric equipment receiving power from direct current power systems with... equipment receiving power from direct current power systems with one polarity grounded. For the purpose of... direct-current power system with one polarity grounded, the following methods of grounding will be...

  5. Determination of the Optimal Fourier Number on the Dynamic Thermal Transmission

    NASA Astrophysics Data System (ADS)

    Bruzgevičius, P.; Burlingis, A.; Norvaišienė, R.

    2016-12-01

    This article represents the result of experimental research on transient heat transfer in a multilayered (heterogeneous) wall. Our non-steady thermal transmission simulation is based on a finite-difference calculation method. The value of a Fourier number shows the similarity of thermal variation in conditional layers of an enclosure. Most scientists recommend using no more than a value of 0.5 for the Fourier number when performing calculations on dynamic (transient) heat transfer. The value of the Fourier number is determined in order to acquire reliable calculation results with optimal accuracy. To compare the results of simulation with experimental research, a transient heat transfer calculation spreadsheet was created. Our research has shown that a Fourier number of around 0.5 or even 0.32 is not sufficient ({≈ }17 % of oscillation amplitude) for calculations of transient heat transfer in a multilayered wall. The least distorted calculation results were obtained when the multilayered enclosure was divided into conditional layers with almost equal Fourier number values and when the value of the Fourier number was around 1/6, i.e., approximately 0.17. Statistical deviation analysis using the Statistical Analysis System was applied to assess the accuracy of the spreadsheet calculation and was developed on the basis of our established methodology. The mean and median absolute error as well as their confidence intervals has been estimated by the two methods with optimal accuracy ({F}_{oMDF}= 0.177 and F_{oEPS}= 0.1633 values).

  6. Validation of hydrogen gas stratification and mixing models

    DOE PAGES

    Wu, Hsingtzu; Zhao, Haihua

    2015-05-26

    Two validation benchmarks confirm that the BMIX++ code is capable of simulating unintended hydrogen release scenarios efficiently. The BMIX++ (UC Berkeley mechanistic MIXing code in C++) code has been developed to accurately and efficiently predict the fluid mixture distribution and heat transfer in large stratified enclosures for accident analyses and design optimizations. The BMIX++ code uses a scaling based one-dimensional method to achieve large reduction in computational effort compared to a 3-D computational fluid dynamics (CFD) simulation. Two BMIX++ benchmark models have been developed. One is for a single buoyant jet in an open space and another is for amore » large sealed enclosure with both a jet source and a vent near the floor. Both of them have been validated by comparisons with experimental data. Excellent agreements are observed. The entrainment coefficients of 0.09 and 0.08 are found to fit the experimental data for hydrogen leaks with the Froude number of 99 and 268 best, respectively. In addition, the BIX++ simulation results of the average helium concentration for an enclosure with a vent and a single jet agree with the experimental data within a margin of about 10% for jet flow rates ranging from 1.21 × 10⁻⁴ to 3.29 × 10⁻⁴ m³/s. In conclusion, computing time for each BMIX++ model with a normal desktop computer is less than 5 min.« less

  7. Methods, Systems and Apparatuses for Radio Frequency Identification

    NASA Technical Reports Server (NTRS)

    Fink, Patrick W. (Inventor); Chu, Andrew W. (Inventor); Lin, Gregory Y. (Inventor); Kennedy, Timothy F. (Inventor); Ngo, Phong H. (Inventor); Brown, Dewey T. (Inventor); Byerly, Diane (Inventor)

    2016-01-01

    A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

  8. Methods, Systems and Apparatuses for Radio Frequency Identification

    NASA Technical Reports Server (NTRS)

    Fink, Patrick W. (Inventor); Chu, Andrew W. (Inventor); Lin, Gregory Y. (Inventor); Kennedy, Timothy F. (Inventor); Ngo, Phong H. (Inventor); Brown, Dewey T. (Inventor); Byerly, Diane (Inventor); Boose, Haley C. (Inventor)

    2015-01-01

    A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

  9. Methods, Systems and Apparatuses for Radio Frequency Identification

    NASA Technical Reports Server (NTRS)

    Brown, Dewey T. (Inventor); Lin, Gregory Y. (Inventor); Kennedy, Timothy F. (Inventor); Byerly, Diane (Inventor); Fink, Patrick W. (Inventor); Chu, Andrew W. (Inventor); Ngo, Phong H. (Inventor)

    2017-01-01

    A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

  10. Method and system for compact efficient laser architecture

    DOEpatents

    Bayramian, Andrew James; Erlandson, Alvin Charles; Manes, Kenneth Rene; Spaeth, Mary Louis; Caird, John Allyn; Deri, Robert J.

    2015-09-15

    A laser amplifier module having an enclosure includes an input window, a mirror optically coupled to the input window and disposed in a first plane, and a first amplifier head disposed along an optical amplification path adjacent a first end of the enclosure. The laser amplifier module also includes a second amplifier head disposed along the optical amplification path adjacent a second end of the enclosure and a cavity mirror disposed along the optical amplification path.

  11. DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

    DOE PAGES

    Capatina, D.; D’Amico, K.; Nudell, J.; ...

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm 2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm 2. Finally, a new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  12. DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capatina, D., E-mail: capatina@aps.anl.gov; D’Amico, K., E-mail: kdamico@aps.anl.gov; Nudell, J., E-mail: jnudell@aps.anl.gov

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  13. DCS - A High Flux Beamline for Time Resolved Dynamic Compression Science – Design Highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capatina, D.; D'Amico, Kevin L.; Nudell, J.

    2016-07-27

    The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures.more » Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm2. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm2. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.« less

  14. 30 CFR 77.701-2 - Approved methods of grounding metallic frames, casings, and other enclosures of electric...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... representative of the Secretary, which insures that there is no difference in potential between such metal... there is no difference in potential between such frames, casings, and other enclosures, and the earth. ...

  15. 30 CFR 77.701-2 - Approved methods of grounding metallic frames, casings, and other enclosures of electric...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... representative of the Secretary, which insures that there is no difference in potential between such metal... there is no difference in potential between such frames, casings, and other enclosures, and the earth. ...

  16. Method for protection of lithographic components from particle contamination

    DOEpatents

    Klebanoff, Leonard E.; Rader, Daniel J.

    2001-07-03

    A system that employs thermophoresis to protect lithographic surfaces from particle deposition and operates in an environment where the pressure is substantially constant and can be sub-atmospheric. The system (thermophoretic pellicle) comprises an enclosure that surrounds a lithographic component whose surface is being protected from particle deposition. The enclosure is provided with means for introducing a flow of gas into the chamber and at least one aperture that provides for access to the lithographic surface for the entry and exit of a beam of radiation, for example, and further controls gas flow into a surrounding low pressure environment such that a higher pressure is maintained within the enclosure and over the surface being protected. The lithographic component can be heated or, alternatively the walls of the enclosure can be cooled to establish a temperature gradient between the surface of the lithographic component and the walls of the enclosure, thereby enabling the thermophoretic force that resists particle deposition.

  17. Thermally induced rarefied gas flow in a three-dimensional enclosure with square cross-section

    NASA Astrophysics Data System (ADS)

    Zhu, Lianhua; Yang, Xiaofan; Guo, Zhaoli

    2017-12-01

    Rarefied gas flow in a three-dimensional enclosure induced by nonuniform temperature distribution is numerically investigated. The enclosure has a square channel-like geometry with alternatively heated closed ends and lateral walls with a linear temperature distribution. A recently proposed implicit discrete velocity method with a memory reduction technique is used to numerically simulate the problem based on the nonlinear Shakhov kinetic equation. The Knudsen number dependencies of the vortices pattern, slip velocity at the planar walls and edges, and heat transfer are investigated. The influences of the temperature ratio imposed at the ends of the enclosure and the geometric aspect ratio are also evaluated. The overall flow pattern shows similarities with those observed in two-dimensional configurations in literature. However, features due to the three-dimensionality are observed with vortices that are not identified in previous studies on similar two-dimensional enclosures at high Knudsen and small aspect ratios.

  18. Negative effects of Microcystis blooms on the crustacean plankton in an enclosure experiment in the subtropical China.

    PubMed

    Chen, Fei-zhou; Xie, Ping; Tang, Hui-juan; Liu, Hong

    2005-01-01

    Effects of Microcystis blooms on the crustacean plankton were studied using enclosure experiments during July-September, 2000. Eight enclosures were set in the hypereutrophic Donghu Lake. Different nutrient concentrations through additional nutrient and sediment in enclosures were expected to result in different abundance of Microcystis. From July to early August, the phytoplankton community was dominated by Chlorophyta, Cryptophyta, Bacillariophyta and Cyanophyta other than Microcystis aeruginosa. M. aeruginosa showed a rapid increase during early August in all enclosures and predominated. Crustacean plankton was dominated by the herbivorous Moina micrura, Diaphanosoma brachyurum and Ceriodaphnia cornuta, and the predaceous Mesocyclops sp. and Thermocyclops taihokuensis. During the pre-bloom period, the dynamics of M. micrura population appeared to be mainly affected by the predaceous cyclopoids. With the development of Microcystis blooms, such interaction between M. micrura and cyclopoids seemed weakened, especially when the Microcystis biomass was high. But there was no apparent influence on the interaction between Leptodora kindti and its zooplanktonic prey. The density of two cyclopoids decreased with the enhancement of Microcystis. The density decline of M. micrura was caused by both predation and inhibition by Microcystis. The low food availability of other edible phytoplankton during the blooms led to low densities of both C. cornuta and D. brachyurum by late August. It appears that dense Microcystis blooms exert strong negative effects on the herbivorous cladocerans and the predaceous cyclopoids.

  19. Fluid bed material transfer method

    DOEpatents

    Pinske, Jr., Edward E.

    1994-01-01

    A fluidized bed apparatus comprising a pair of separated fluid bed enclosures, each enclosing a fluid bed carried on an air distributor plate supplied with fluidizing air from below the plate. At least one equalizing duct extending through sidewalls of both fluid bed enclosures and flexibly engaged therewith to communicate the fluid beds with each other. The equalizing duct being surrounded by insulation which is in turn encased by an outer duct having expansion means and being fixed between the sidewalls of the fluid bed enclosures.

  20. System and Method for Isolation of Samples

    NASA Technical Reports Server (NTRS)

    Zhang, Ye (Inventor); Wu, Honglu (Inventor)

    2014-01-01

    Systems and methods for isolating samples are provided. The system comprises a first membrane and a second membrane disposed within an enclosure. First and second reservoirs can also be disposed within the enclosure and adapted to contain one or more reagents therein. A first valve can be disposed within the enclosure and in fluid communication with the first reservoir, the second reservoir, or both. The first valve can also be in fluid communication with the first or second membranes or both. The first valve can be adapted to selectively regulate the flow of the reagents from the first reservoir, through at least one of the first and second membranes, and into the second reservoir.

  1. The Lightning Electromagnetic Pulse Coupling Effect Inside the Shielding Enclosure With Penetrating Wire

    NASA Astrophysics Data System (ADS)

    Jiao, Xue; Yang, Bo

    2017-10-01

    To study the lightning electromagnetic pulse (LEMP) coupling and protection problems of shielding enclosure with penetrating wire, we adopt the model with proper size which is close to the practical engineering and the two-step finite-difference time-domain (FDTD) method is used for calculation in this paper. It is shown that the coupling voltage on the circuit lead inside the enclosure increases about 34 dB, when add 1.0 m long penetrating wire at the aperture, comparing with the case without penetrating wire. Meanwhile, the waveform, has the same wave outline as the lightning current source, shows that the penetrating wire brings a large number of low frequency component into the enclosure. The coupling effect in the enclosure will reduce greatly when penetrating wire has electrical connection with the enclosure at the aperture and the coupling voltage increase only about 12 dB than the case without penetrating wire. Moreover, the results show that though the waveguide pipe can reduce the coupling effect brought by the penetrating wire, the exposing part of penetrating wire can increase the coupling when the penetrating wire outside the enclosure is longer than the waveguide pipe and the longer the exposing part is, the stronger the coupling is.

  2. Fiber-Reinforced Epoxy Composites and Methods of Making Same Without the Use of Oven or Autoclave

    NASA Technical Reports Server (NTRS)

    Barnell, Thomas J. (Inventor); Rauscher, Michael D. (Inventor); Stienecker, Rick D. (Inventor); Nickerson, David M. (Inventor); Tong, Tat H. (Inventor)

    2016-01-01

    Method embodiments for producing a fiber-reinforced epoxy composite comprise providing a mold defining a shape for a composite, applying a fiber reinforcement over the mold, covering the mold and fiber reinforcement thereon in a vacuum enclosure, performing a vacuum on the vacuum enclosure to produce a pressure gradient, insulating at least a portion of the vacuum enclosure with thermal insulation, infusing the fiber reinforcement with a reactive mixture of uncured epoxy resin and curing agent under vacuum conditions, wherein the reactive mixture of uncured epoxy resin and curing agent generates exothermic heat, and producing the fiber-reinforced epoxy composite having a glass transition temperature of at least about 100.degree. C. by curing the fiber reinforcement infused with the reactive mixture of uncured epoxy resin and curing agent by utilizing the exothermically generated heat, wherein the curing is conducted inside the thermally insulated vacuum enclosure without utilization of an external heat source or an external radiation source.

  3. High-temperature potentiometric oxygen sensor with internal reference

    DOEpatents

    Routbort, Jules L [Hinsdale, IL; Singh, Dileep [Naperville, IL; Dutta, Prabir K [Worthington, OH; Ramasamy, Ramamoorthy [North Royalton, OH; Spirig, John V [Columbus, OH; Akbar, Sheikh [Hilliard, OH

    2011-11-15

    A compact oxygen sensor is provided, comprising a mixture of metal and metal oxide an enclosure containing said mixture, said enclosure capable of isolating said mixture from an environment external of said enclosure, and a first wire having a first end residing within the enclosure and having a second end exposed to the environment. Also provided is a method for the fabrication of an oxygen sensor, the method comprising confining a metal-metal oxide solid mixture to a container which consists of a single material permeable to oxygen ions, supplying an electrical conductor having a first end and a second end, whereby the first end resides inside the container as a reference (PO.sub.2).sup.ref, and the second end resides outside the container in the atmosphere where oxygen partial pressure (PO.sub.2).sup.ext is to be measured, and sealing the container with additional single material such that grain boundary sliding occurs between grains of the single material and grains of the additional single material.

  4. Plasma confinement system and methods for use

    DOEpatents

    Jarboe, Thomas R.; Sutherland, Derek

    2017-09-05

    A plasma confinement system is provided that includes a confinement chamber that includes one or more enclosures of respective helicity injectors. The one or more enclosures are coupled to ports at an outer radius of the confinement chamber. The system further includes one or more conductive coils aligned substantially parallel to the one or more enclosures and a further set of one or more conductive coils respectively surrounding portions of the one or more enclosures. Currents may be provided to the sets of conductive coils to energize a gas within the confinement chamber into a plasma. Further, a heat-exchange system is provided that includes an inner wall, an intermediate wall, an outer wall, and pipe sections configured to carry coolant through cavities formed by the walls.

  5. Performance criteria guideline for three explosion protection methods of electrical equipment rated up to 15,000 volts AC

    NASA Technical Reports Server (NTRS)

    Linley, L. J.; Luper, A. B.; Dunn, J. H.

    1982-01-01

    The Bureau of Mines, U.S. Department of the Interior, is reviewing explosion protection methods for use in gassy coal mines. This performance criteria guideline is an evaluation of three explosion protection methods of machines electrically powered with voltages up to 15,000 volts ac. A sufficient amount of basic research has been accomplished to verify that the explosion proof and pressurized enclosure methods can provide adequate explosion protection with the present state of the art up to 15,000 volts ac. This routine application of the potted enclosure as a stand alone protection method requires further investigation or development in order to clarify performance criteria and verification certification requirements. An extensive literature search, a series of high voltage tests, and a design evaluation of the three explosion protection methods indicate that the explosion proof, pressurized, and potted enclosures can all be used to enclose up to 15,000 volts ac.

  6. Population Density and Seasonality Effects on Sin Nombre Virus Transmission in North American Deermice (Peromyscus maniculatus) in Outdoor Enclosures

    PubMed Central

    Bagamian, Karoun H.; Douglass, Richard J.; Alvarado, Arlene; Kuenzi, Amy J.; Amman, Brian R.; Waller, Lance A.; Mills, James N.

    2012-01-01

    Surveys of wildlife host-pathogen systems often document clear seasonal variation in transmission; conclusions concerning the relationship between host population density and transmission vary. In the field, effects of seasonality and population density on natural disease cycles are challenging to measure independently, but laboratory experiments may poorly reflect what happens in nature. Outdoor manipulative experiments are an alternative that controls for some variables in a relatively natural environment. Using outdoor enclosures, we tested effects of North American deermouse (Peromyscus maniculatus) population density and season on transmission dynamics of Sin Nombre hantavirus. In early summer, mid-summer, late summer, and fall 2007–2008, predetermined numbers of infected and uninfected adult wild deermice were released into enclosures and trapped weekly or bi-weekly. We documented 18 transmission events and observed significant seasonal effects on transmission, wounding frequency, and host breeding condition. Apparent differences in transmission incidence or wounding frequency between high- and low-density treatments were not statistically significant. However, high host density was associated with a lower proportion of males with scrotal testes. Seasonality may have a stronger influence on disease transmission dynamics than host population density, and density effects cannot be considered independent of seasonality. PMID:22768034

  7. Efficiency Evaluation of Nozawa-Style Black Light Trap for Control of Anopheline Mosquitoes

    PubMed Central

    Lee, Hee Il; Seo, Bo Youl; Shin, E-Hyun; Burkett, Douglas A.; Lee, Jong-Koo

    2009-01-01

    House-residual spraying and insecticide-treated bed nets have achieved some success in controlling anthropophilic and endophagic vectors. However, these methods have relatively low efficacy in Korea because Anopheles sinensis, the primary malaria vector, is highly zoophilic and exophilic. So, we focused our vector control efforts within livestock enclosures using ultraviolet black light traps as a mechanical control measure. We found that black light traps captured significantly more mosquitoes at 2 and 2.5 m above the ground (P < 0.05). We also evaluated the effectiveness of trap spacing within the livestock enclosure. In general, traps spaced between 4 and 7 m apart captured mosquitoes more efficiently than those spaced closer together (P > 0.05). Based on these findings, we concluded that each black light trap in the livestock enclosures killed 7,586 female mosquitoes per trap per night during the peak mosquito season (July-August). In May-August 2003, additional concurrent field trials were conducted in Ganghwa county. We got 74.9% reduction (P < 0.05) of An. sinensis in human dwellings and 61.5% reduction (P > 0.05) in the livestock enclosures. The black light trap operation in the livestock enclosures proved to be an effective control method and should be incorporated into existing control strategies in developed countries. PMID:19488423

  8. Detection of free liquid in containers of solidified radioactive waste

    DOEpatents

    Greenhalgh, Wilbur O.

    1985-01-01

    A method of nondestructively detecting the presence of free liquid within a sealed enclosure containing solidified waste by measuring the levels of waste at two diametrically opposite locations while slowly tilting the enclosure toward one of said locations. When the measured level remains constant at the other location, the measured level at said one location is noted and any measured difference of levels indicates the presence of liquid on the surface of the solidified waste. The absence of liquid in the enclosure is verified when the measured levels at both locations are equal.

  9. Aerothermodynamic properties of stretched flames in enclosures

    NASA Astrophysics Data System (ADS)

    Rotman, D. A.; Oppenheim, A. K.

    Flames are stretched by being pulled along their frontal surface by the flow field in which they reside. Their trajectories tend to approach particle paths, acquiring eventually the role of contact boundaries, -interfaces between the burnt and unburnt medium that may broaden solely as a consequence of diffusion. Fundamental properties of flow fields governing such flames are determined here on the basis of the zero Mach number model, providng a rational method of approach to the computational analysis of combustion fields in enclosures where, besides the aerodynamic properties flow, the thermodynamic process of compression must be taken into account. To illustrate its application, the method is used to reveal the mechanism of formation of a tulip-shape flame in a rectangular enclosure under nonturbulent flow conditions.

  10. Electromagnetic Field Penetration Studies

    NASA Technical Reports Server (NTRS)

    Deshpande, M.D.

    2000-01-01

    A numerical method is presented to determine electromagnetic shielding effectiveness of rectangular enclosure with apertures on its wall used for input and output connections, control panels, visual-access windows, ventilation panels, etc. Expressing EM fields in terms of cavity Green's function inside the enclosure and the free space Green's function outside the enclosure, integral equations with aperture tangential electric fields as unknown variables are obtained by enforcing the continuity of tangential electric and magnetic fields across the apertures. Using the Method of Moments, the integral equations are solved for unknown aperture fields. From these aperture fields, the EM field inside a rectangular enclosure due to external electromagnetic sources are determined. Numerical results on electric field shielding of a rectangular cavity with a thin rectangular slot obtained using the present method are compared with the results obtained using simple transmission line technique for code validation. The present technique is applied to determine field penetration inside a Boeing-757 by approximating its passenger cabin as a rectangular cavity filled with a homogeneous medium and its passenger windows by rectangular apertures. Preliminary results for, two windows, one on each side of fuselage were considered. Numerical results for Boeing-757 at frequencies 26 MHz, 171-175 MHz, and 428-432 MHz are presented.

  11. Investigation of Heat and Mass Transfer and Irreversibility Phenomena Within a Three-Dimensional Tilted Enclosure for Different Shapes

    NASA Astrophysics Data System (ADS)

    Oueslati, F.; Ben-Beya, B.

    2018-01-01

    Three-dimensional thermosolutal natural convection and entropy generation within an inclined enclosure is investigated in the current study. A numerical method based on the finite volume method and a full multigrid technique is implemented to solve the governing equations. Effects of various parameters, namely, the aspect ratio, buoyancy ratio, and tilt angle on the flow patterns and entropy generation are predicted and discussed.

  12. Effects of the inclination angle on the performance of flat plate solar collector

    NASA Astrophysics Data System (ADS)

    Ambarita, H.; Siregar, R. E. T.; Ronowikarto, A. D.; Setyawan, E. Y.

    2018-03-01

    Double glasses cover is typically used in a flat plate solar collector to decrease heat losses to ambient. The working principal of the cover is to allow the solar irradiation hit the plate absorber and blocks it using natural convection mechanism in the enclosure between the glasses. The performance of the enclosure to block the heat loss to the surrounding affected by the inclination angle of the collector. The objective of this study is to explore the effect of the inclination angle to the performance of the solar collector. Numerical simulation using commercial code Computational Fluid Dynamic (CFD) has been carried out to explore the fluid flow and heat transfer characteristics in the enclosure. In the result, streamline, vector velocity, and contour temperature are plotted. It was shown that the inclination angle strongly affects the performance of the collector. The average heat transfer coefficient decreases with increasing inclination angle. This fact suggests that too high inclination angle is not recommended for solar collector.

  13. Enclosure fire hazard analysis using relative energy release criteria. [burning rate and combustion control

    NASA Technical Reports Server (NTRS)

    Coulbert, C. D.

    1978-01-01

    A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.

  14. Review of methods for determination of ammonia volatilization in farmland

    NASA Astrophysics Data System (ADS)

    Yang, J.; Jiao, Y.; Yang, W. Z.; Gu, P.; Bai, S. G.; Liu, L. J.

    2018-02-01

    Ammonia is one of the most abundant alkaline trace gases in the atmosphere, which is one of the important factors affecting atmospheric quality. Excessive application of nitrogen fertilizer is the main source of global ammonia emissions, which not only exacerbate greenhouse gas emissions, but also leads to eutrophication of water bodies. In this paper, the basic principle, the operation process, the advantages and disadvantages, and the previous research results of the method are summarized in detail, including the enclosure method, the venting method, the continuous airflow enclosure method, the wind tunnel method and the micro-meteorological method. So as to provide a theoretical basis for selecting the appropriate method for determination of ammonia volatilization.

  15. High-order computer-assisted estimates of topological entropy

    NASA Astrophysics Data System (ADS)

    Grote, Johannes

    The concept of Taylor Models is introduced, which offers highly accurate C0-estimates for the enclosures of functional dependencies, combining high-order Taylor polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified interval arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly nonlinear dynamical systems. A method to obtain sharp rigorous enclosures of Poincare maps for certain types of flows and surfaces is developed and numerical examples are presented. Differential algebraic techniques allow the efficient and accurate computation of polynomial approximations for invariant curves of certain planar maps around hyperbolic fixed points. Subsequently we introduce a procedure to extend these polynomial curves to verified Taylor Model enclosures of local invariant manifolds with C0-errors of size 10-10--10 -14, and proceed to generate the global invariant manifold tangle up to comparable accuracy through iteration in Taylor Model arithmetic. Knowledge of the global manifold structure up to finite iterations of the local manifold pieces enables us to find all homoclinic and heteroclinic intersections in the generated manifold tangle. Combined with the mapping properties of the homoclinic points and their ordering we are able to construct a subshift of finite type as a topological factor of the original planar system to obtain rigorous lower bounds for its topological entropy. This construction is fully automatic and yields homoclinic tangles with several hundred homoclinic points. As an example rigorous lower bounds for the topological entropy of the Henon map are computed, which to the best knowledge of the authors yield the largest such estimates published so far.

  16. Near and far field contamination modeling in a large scale enclosure: Fire Dynamics Simulator comparisons with measured observations.

    PubMed

    Ryder, Noah L; Schemel, Christopher F; Jankiewicz, Sean P

    2006-03-17

    The occurrence of a fire, no matter how small, often exposes objects to significant levels of contamination from the products of combustion. The production and dispersal of these contaminants has been an issue of relevance in the field of fire science for many years, though little work has been done to examine the contamination levels accumulated within an enclosure some time after an incident. This phenomenon is of great importance when considering the consequences associated with even low level contamination of sensitive materials, such as food, pharmaceuticals, clothing, electrical equipment, etc. Not only does such exposure present a localized hazard, but also the shipment of contaminated goods places distant recipients at risk. It is the intent of this paper to use a well-founded computational fluid dynamic (CFD) program, the Fire Dynamics Simulator (FDS), a large eddy simulation (LES) code developed by National Institute of Standards and Technology (NIST), to model smoke dispersion in order to assess the subject of air contamination and post fire surface contamination in a warehouse facility. Measured results are then compared with the results from the FDS model. Two components are examined: the production rate of contaminates and the trajectory of contaminates caused by the forced ventilation conditions. Each plays an important role in determining the extent to which the products of combustion are dispersed and the levels to which products are exposed to the contaminants throughout the enclosure. The model results indicate a good first-order approximation to the measured surface contamination levels. The proper application of the FDS model can provide a cost and time efficient means of evaluating contamination levels within a defined volume.

  17. 40 CFR 63.3965 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Method 204A or 204F of appendix M to 40 CFR part 51 to determine the mass fraction of TVH liquid input... temporary total enclosure or building enclosure. The liquid-to-uncaptured-gas protocol compares the mass of liquid TVH in materials used in the coating operation to the mass of TVH emissions not captured by the...

  18. Radiant heat exchange calculations in radiantly heated and cooled enclosures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, K.S.; Zhang, P.

    1995-08-01

    This paper presents the development of a three-dimensional mathematical model to compute the radiant heat exchange between surfaces separated by a transparent and/or opaque medium. The model formulation accommodates arbitrary arrangements of the interior surfaces, as well as arbitrary placement of obstacles within the enclosure. The discrete ordinates radiation model is applied and has the capability to analyze the effect of irregular geometries and diverse surface temperatures and radiative properties. The model is verified by comparing calculated heat transfer rates to heat transfer rates determined from the exact radiosity method for four different enclosures. The four enclosures were selected tomore » provide a wide range of verification. This three-dimensional model based on the discrete ordinates method can be applied to a building to assist the design engineer in sizing a radiant heating system. By coupling this model with a convective and conductive heat transfer model and a thermal comfort model, the comfort levels throughout the room can be easily and efficiently mapped for a given radiant heater location. In addition, objects such as airplanes, trucks, furniture, and partitions can be easily incorporated to determine their effect on the performance of the radiant heating system.« less

  19. Noise transmission from a curved panel into a cylindrical enclosure: analysis of structural acoustic coupling.

    PubMed

    Henry, J K; Clark, R L

    2001-04-01

    Much of the research on sound transmission through the aircraft fuselage into the interior of aircraft has considered coupling of the entire cylinder to the acoustic modes of the enclosure. Yet, much of the work on structural acoustic control of sound radiation has focused on reducing sound radiation from individual panels into an acoustic space. Research by the authors seeks to bridge this gap by considering the transmission of sound from individual panels on the fuselage to the interior of the aircraft. As part of this research, an analytical model of a curved panel, with attached piezoelectric actuators, subjected to a static pressure load was previously developed. In the present work, the analytical model is extended to consider the coupling of a curved panel to the interior acoustics of a rigid-walled cylinder. Insight gained from an accurate analytical model of the dynamics of the noise transmission from the curved panels of the fuselage into the cylindrical enclosure of an aircraft is essential to the development of feedback control systems for the control of stochastic inputs, such as turbulent boundary layer excitation. The criteria for maximal structural acoustic coupling between the modes of the curved panel and the modes of the cylindrical enclosure are studied. For panels with aspect ratios typical of those found in aircraft, results indicate that predominately axial structural modes couple most efficiently to the acoustic modes of the enclosure. The effects of the position of the curved panel on the cylinder are also studied. Structural acoustic coupling is found to not be significantly affected by varying panel position. The impact of the findings of this study on structural acoustic control design is discussed.

  20. Heat Transfer and Fluid Mechanics Institute, Meeting, 25th, University of California, Davis, Calif., June 21-23, 1976, Proceedings

    NASA Technical Reports Server (NTRS)

    Mckillop, A. A.; Baughn, J. W.; Dwyer, H. A.

    1976-01-01

    Major research advances in heat transfer and fluid dynamics are outlined, with particular reference to relevant energy problems. Of significant importance are such topics as synthetic fuels in combustion, turbulence models, combustion modeling, numerical methods for interacting boundary layers, and light-scattering diagnostics for gases. The discussion covers thermal convection, two-phase flow and boiling heat transfer, turbulent flows, combustion, and aerospace heat transfer problems. Other areas discussed include compressible flows, fluid mechanics and drag, and heat exchangers. Featured topics comprise heat and salt transfer in double-diffusive systems, limits of boiling heat transfer in a liquid-filled enclosure, investigation of buoyancy-induced flow stratification in a cylindrical plenum, and digital algorithms for dynamic analysis of a heat exchanger. Individual items are announced in this issue.

  1. Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

    DOEpatents

    Burks, Morgan Thomas; Eckels, Joel Del

    2010-06-08

    In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

  2. Vibration measurements of the Daniel K. Inouye Solar Telescope mount, Coudé rotator, and enclosure assemblies

    NASA Astrophysics Data System (ADS)

    McBride, William R.; McBride, Daniel R.

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) will be the largest solar telescope in the world, with a 4-meter off-axis primary mirror and 16 meter rotating Coudé laboratory within the telescope pier. The off-axis design requires a mount similar to an 8-meter on-axis telescope. Both the telescope mount and the Coudé laboratory utilize a roller bearing technology in place of the more commonly used hydrostatic bearings. The telescope enclosure utilizes a crawler mechanism for the altitude axis. As these mechanisms have not previously been used in a telescope, understanding the vibration characteristics and the potential impact on the telescope image is important. This paper presents the methodology used to perform jitter measurements of the enclosure and the mount bearings and servo system in a high-noise environment utilizing seismic accelerometers and high dynamic-range data acquisition equipment, along with digital signal processing (DSP) techniques. Data acquisition and signal processing were implemented in MATLAB. In the factory acceptance testing of the telescope mount, multiple accelerometers were strategically located to capture the six axes-of-motion of the primary and secondary mirror dummies. The optical sensitivity analysis was used to map these mirror mount displacements and rotations into units of image motion on the focal plane. Similarly, tests were done with the Coudé rotator, treating the entire rotating instrument lab as a rigid body. Testing was performed by recording accelerometer data while the telescope control system performed tracking operations typical of various observing scenarios. The analysis of the accelerometer data utilized noise-averaging fast Fourier transform (FFT) routines, spectrograms, and periodograms. To achieve adequate dynamic range at frequencies as low as 3Hz, the use of special filters and advanced windowing functions were necessary. Numerous identical automated tests were compared to identify and select the data sets with the lowest level of external interference. Similar testing was performed on the telescope enclosure during the factory test campaign. The vibration of the enclosure altitude and azimuth mechanisms were characterized. This paper details jitter tests using accelerometers placed in locations that allowed the motion of the assemblies to be measured while the control system performed various moves typical of on-sky observations. The measurements were converted into the rigid body motion of the structures and mapped into image motion using the telescope's optical sensitivity analysis.

  3. Method of using infrared radiation for assembling a first component with a second component

    DOEpatents

    Sikka, Vinod K.; Whitson, Barry G.; Blue, Craig A.

    1999-01-01

    A method of assembling a first component for assembly with a second component involves a heating device which includes an enclosure having a cavity for inserting a first component. An array of infrared energy generators is disposed within the enclosure. At least a portion of the first component is inserted into the cavity, exposed to infrared energy and thereby heated to a temperature wherein the portion of the first component is sufficiently softened and/or expanded for assembly with a second component.

  4. Numerical Models for Sound Propagation in Long Spaces

    NASA Astrophysics Data System (ADS)

    Lai, Chenly Yuen Cheung

    Both reverberation time and steady-state sound field are the key elements for assessing the acoustic condition in an enclosed space. They affect the noise propagation, speech intelligibility, clarity index, and definition. Since the sound field in a long space is non diffuse, classical room acoustics theory does not apply in this situation. The ray tracing technique and the image source methods are two common models to fathom both reverberation time and steady-state sound field in long enclosures nowadays. Although both models can give an accurate estimate of reverberation times and steady-state sound field directly or indirectly, they often involve time-consuming calculations. In order to simplify the acoustic consideration, a theoretical formulation has been developed for predicting both steady-state sound fields and reverberation times in street canyons. The prediction model is further developed to predict the steady-state sound field in a long enclosure. Apart from the straight long enclosure, there are other variations such as a cross junction, a long enclosure with a T-intersection, an U-turn long enclosure. In the present study, an theoretical and experimental investigations were conducted to develop formulae for predicting reverberation times and steady-state sound fields in a junction of a street canyon and in a long enclosure with T-intersection. The theoretical models are validated by comparing the numerical predictions with published experimental results. The theoretical results are also compared with precise indoor measurements and large-scale outdoor experimental results. In all of previous acoustical studies related to long enclosure, most of the studies are focused on the monopole sound source. Besides non-directional noise source, many noise sources in long enclosure are dipole like, such as train noise and fan noise. In order to study the characteristics of directional noise sources, a review of available dipole source was conducted. A dipole was constructed which was subsequent used for experimental studies. In additional, a theoretical model was developed for predicting dipole sound fields. The theoretical model can be used to study the effect of a dipole source on the speech intelligibility in long enclosures.

  5. POPULATION DYNAMICS OF COTTON RATS ACROSS A LANDSCAPE MANIPULATED BY NITROGEN ADDITIONS AND ENCLOSURE FENCING

    EPA Science Inventory

    Nitrogen additions in grasslands have produced qualitative and quantitative changes in vegetation resulting in an increase in biomass and decrease in plant species diversity. As with plants, we theorize that animal communities will decrease in species richness and become dominat...

  6. Material containment enclosure

    DOEpatents

    Carlson, David O.

    1993-01-01

    An isolation enclosure and a group of isolation enclosures useful when a relatively large containment area is required. The enclosure is in the form of a ring having a section removed so that a technician may enter the center area of the ring. In a preferred embodiment, an access zone is located in the transparent wall of the enclosure and extends around the inner perimeter of the ring so that a technician can insert his hands into the enclosure to reach any point within. The inventive enclosures provide more containment area per unit area of floor space than conventional material isolation enclosures.

  7. Leaf litter bags as an index to populations of northern two-lined salamanders (Eurycea bislineata)

    USGS Publications Warehouse

    Chalmers, R.J.; Droege, S.

    2002-01-01

    Concern about recent amphibian declines has led to research on amphibian populations, but few statistically tested, standardized methods of counting amphibians exist. We tested whether counts of northern two-lined salamander larvae (Eurycea bislineata) sheltered in leaf litter bags--a relatively new, easily replicable survey technique--had a linear correlation to total number of larvae. Using experimental enclosures placed in streams, we compared number of salamanders found in artificial habitat (leaf litter bags) with total number of salamanders in each enclosure. Low numbers of the animals were found in leaf litter bags, and the relative amount of variation in the index (number of animals in leaf litter bags compared to total number of animals in stream enclosures) was high. The index of salamanders in leaf litter bags was not significantly related to total number of salamanders in enclosures for two-thirds of the replicates or with pooled replicates (P= 0.066). Consequently, we cannot recommend using leaf litter bags to index populations of northern two-lined salamanders.

  8. Boundary conditions for the solution of the three-dimensional Poisson equation in open metallic enclosures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Debabrata; Singh, Gaurav; Kumar, Raghwendra

    2015-09-15

    Numerical solution of the Poisson equation in metallic enclosures, open at one or more ends, is important in many practical situations, such as high power microwave or photo-cathode devices. It requires imposition of a suitable boundary condition at the open end. In this paper, methods for solving the Poisson equation are investigated for various charge densities and aspect ratios of the open ends. It is found that a mixture of second order and third order local asymptotic boundary conditions is best suited for large aspect ratios, while a proposed non-local matching method, based on the solution of the Laplace equation,more » scores well when the aspect ratio is near unity for all charge density variations, including ones where the centre of charge is close to an open end or the charge density is non-localized. The two methods complement each other and can be used in electrostatic calculations where the computational domain needs to be terminated at the open boundaries of the metallic enclosure.« less

  9. Solar-Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2001-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  10. Solar-Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  11. Solar Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  12. Material isolation enclosure

    DOEpatents

    Martell, Calvin J.; Dahlby, Joel W.; Gallimore, Bradford F.; Comer, Bob E.; Stone, Water A.; Carlson, David O.

    1993-01-01

    An enclosure similar to a glovebox for isolating materials from the atmosphere, yet allowing a technician to manipulate the materials and also apparatus which is located inside the enclosure. A portion of a wall of the enclosure is comprised of at least one flexible curtain. An opening defined by a frame is provided for the technician to insert his hands and forearms into the enclosure. The frame is movable in one plane, so that the technician has access to substantially all of the working interior of the enclosure. As the frame is moved by the technician, while he accomplishes work inside the enclosure, the curtain moves such that the only opening through the enclosure wall is the frame. In a preferred embodiment, where a negative pressure is maintained inside the enclosure, the frame is comprised of airfoils so that turbulence is reduced, thereby enhancing material retention within the box.

  13. Apparatus for detecting alpha radiation in difficult access areas

    DOEpatents

    Steadman, Peter; MacArthur, Duncan W.

    1997-09-02

    An electrostatic alpha radiation detector for measuring alpha radiation emitted from inside an enclosure comprising an electrically conductive expandable electrode for insertion into the enclosure. After insertion, the electrically conductive expandable electrode is insulated from the enclosure and defines a decay cavity between the electrically conductive expandable electrode and the enclosure so that air ions generated in the decay cavity are electrostatically captured by the electrically conductive expandable electrode and the enclosure when an electric potential is applied between the electrically conductive expandable electrode and the enclosure. Indicator means are attached to the electrically conductive expandable electrode for indicating an electrical current produced by generation of the air ions generated in the decay cavity by collisions between air molecules and the alpha particles emitted from the enclosure. A voltage source is connected between the indicator means and the electrically conductive enclosure for creating an electric field between the electrically conductive expandable electrode and the enclosure.

  14. Material isolation enclosure

    DOEpatents

    Martell, C.J.; Dahlby, J.W.; Gallimore, B.F.; Comer, B.E.; Stone, W.A.; Carlson, D.O.

    1993-04-27

    An enclosure is described, similar to a glove box, for isolating materials from the atmosphere, yet allowing a technician to manipulate the materials and also apparatus which is located inside the enclosure. A portion of a wall of the enclosure is comprised of at least one flexible curtain. An opening defined by a frame is provided for the technician to insert his hands and forearms into the enclosure. The frame is movable in one plane, so that the technician has access to substantially all of the working interior of the enclosure. As the frame is moved by the technician, while he accomplishes work inside the enclosure, the curtain moves such that the only opening through the enclosure wall is the frame. In a preferred embodiment, where a negative pressure is maintained inside the enclosure, the frame is comprised of airfoils so that turbulence is reduced, thereby enhancing material retention within the box.

  15. Monitoring the dynamic emission of biogenic volatile organic compounds from Cryptomeria japonica by enclosure measurement

    NASA Astrophysics Data System (ADS)

    Lin, Chun-Ya; Chang, Tzu-Cheng; Chen, Yu-Han; Chen, Ying-Ju; Cheng, Sen-Sung; Chang, Shang-Tzen

    2015-12-01

    Research on biogenic volatile organic compounds (BVOCs) emitted from trees is essential in the world since these BVOCs play an important role in the atmospheric process which may further influence on the air quality. However, little is known about BVOCs emitted from trees in the field in Taiwan. Hence, this study intends to establish an enclosure technique coupled with in situ sampling to facilitate the collection of BVOCs emitted from Cryptomeria japonica leaves. Furthermore, the emission model derived from the relationship between emission rate and temperature was applied to estimate the emission of BVOCs in the field. Results from GC-MS showed that the BVOCs emitted from intact leaves contain 14 monoterpenoids and 4 sesquiterpenoid. The emission rate of the major constituent, sabinene, was 0.42 μg h-1 g-1 around noon on September 11, 2013. Sabinene varies with the changing temperature inside the bag. These findings indicated that the enclosure technique can collect the BVOCs emitted from intact leaves and monitor the dynamic changes in emission. Two determinants, basal emission rate (at 30 °C) and β coefficient, of sabinene were further measured, and they were 1.29 μg h-1 g-1 and 0.18 °C-1, respectively. By using these two determinants and data of meteorology and forest resource, the emission of monoterpenes from C. japonica stand was estimated to be 1.13 mg m-2 h-1 in July in Xitou area. Taken together, the results provide valuable information for estimation of BVOCs from tree species in Taiwan for the first time.

  16. Vortex ventilation in the laboratory environment.

    PubMed

    Meisenzahl, Lawrence R

    2014-01-01

    Assured containment at low airflow has long eluded the users of ventilated enclosures including chemical fume hoods used throughout industry. It is proposed that containment will be enhanced in a hood that has a particular interior shape that causes a natural vortex to occur. The sustained vortex improves the containment of contaminants within the enclosure at low airflow. This hypothesis was tested using the ASHRAE 110 tracer gas test. A known volume of tracer gas was emitted in the hood. A MIRAN SapphIRe infrared spectrometer was used to measure the concentration of tracer gas that escapes the enclosure. The design of the experiment included a written operating procedure, data collection plan, and statistical analysis of the data. A chemical fume hood of traditional design was tested. The hood interior was then reconstructed to enhance the development of a vortex inside the enclosure. The hood was retested using the same method to compare the performance of the traditional interior shape with the enhanced vortex shape. In every aspect, the vortex hood showed significant improvement over the traditional hood design. Use of the Hood Index characterizing the dilution of gas in an air stream as a logarithmic function indicates a causal relationship between containment and volumetric airflow through an enclosure. Use of the vortex effect for ventilated enclosures can provide better protection for the user and lower operating cost for the owner. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a data collection spreadsheet, data analysis, and data collection procedure.].

  17. Computational Fluid Dynamics (CFD) Analysis Of Optical Payload For Lasercomm Science (OPALS) sealed enclosure module

    NASA Technical Reports Server (NTRS)

    Anderson, Kevin R.; Zayas, Daniel; Turner, Daniel

    2012-01-01

    Computational Fluid Dynamics (CFD) using the commercial CFD package CFDesign has been performed at NASA Jet Propulsion Laboratory (JPL) California Institute of Technology (Caltech) in support of the Phaeton Early Career Hire Program's Optical Payload for Lasercomm Science (OPALS) mission. The OPALS project is one which involves an International Space Station payload that will be using forced convection cooling in a hermetically sealed enclosure at 1 atm of air to cool "off-the-shelf" vendor electronics. The CFD analysis was used to characterize the thermal and fluid flow environment within a complicated labyrinth of electronics boards, fans, instrumentation, harnessing, ductwork and heat exchanger fins. The paradigm of iteratively using CAD/CAE tools and CFD was followed in order to determine the optimum flow geometry and heat sink configuration to yield operational convective film coefficients and temperature survivability limits for the electronics payload. Results from this current CFD analysis and correlation of the CFD model against thermal test data will be presented. Lessons learned and coupled thermal / flow modeling strategies will be shared in this paper.

  18. Self contained, independent, in-vacuum spinner motor

    DOEpatents

    Ayers, Marion J.

    2002-01-01

    An independent, self contained apparatus for operation within a vacuum chamber. A sealed enclosure is located in the chamber. The enclosure contains its own atmosphere independent of the vacuum in the chamber. A motor, power unit, and controls are located entirely within the enclosure. They do not have a direct structural connection outside of the enclosure in any way that would effect the atmosphere within the enclosure. The motor, power unit, and controls drive a spinner plate located outside the enclosure but within the vacuum chamber.

  19. Development of a Reduced-Order Three-Dimensional Flow Model for Thermal Mixing and Stratification Simulation during Reactor Transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Rui

    2017-09-03

    Mixing, thermal-stratification, and mass transport phenomena in large pools or enclosures play major roles for the safety of reactor systems. Depending on the fidelity requirement and computational resources, various modeling methods, from the 0-D perfect mixing model to 3-D Computational Fluid Dynamics (CFD) models, are available. Each is associated with its own advantages and shortcomings. It is very desirable to develop an advanced and efficient thermal mixing and stratification modeling capability embedded in a modern system analysis code to improve the accuracy of reactor safety analyses and to reduce modeling uncertainties. An advanced system analysis tool, SAM, is being developedmore » at Argonne National Laboratory for advanced non-LWR reactor safety analysis. While SAM is being developed as a system-level modeling and simulation tool, a reduced-order three-dimensional module is under development to model the multi-dimensional flow and thermal mixing and stratification in large enclosures of reactor systems. This paper provides an overview of the three-dimensional finite element flow model in SAM, including the governing equations, stabilization scheme, and solution methods. Additionally, several verification and validation tests are presented, including lid-driven cavity flow, natural convection inside a cavity, laminar flow in a channel of parallel plates. Based on the comparisons with the analytical solutions and experimental results, it is demonstrated that the developed 3-D fluid model can perform very well for a wide range of flow problems.« less

  20. On the Method of Efficient Ice Cold Energy Storage Using a Heat Transfer of Direct Contact Phase Change and a Natural Circulation of a Working Medium in an Enclosure

    NASA Astrophysics Data System (ADS)

    Utaka, Yoshio; Saito, Akio; Nakata, Naoki

    The objectives of this report are to propose a new method of the high performance cold energy storage using ice as a phase change material and to clarify the heat transfer characteristics of the apparatus of ice cold energy storage based on the proposed principle. A working medium vapor layer a water layer and a working medium liquid layer stratified in this order from the top were kept in an enclosure composed of a condenser, an evaporator and a condensate receiver-and-return tube. The direct contact heat transfers between water or ice and a working medium in an enclosure were applied for realizing the high performance cold energy storage and release. In the storage and release processes, water changes the phase between the liquid and the solid, and the working medium cnanges between the vapor and the liquid with a natural circulation. Experimental apparatus was manufactured and R12 and R114 were selected as working media in the thermal energy storage enclosure. It was confirmed by the measurements that the efficient formation and melting of ice were achieved. Then, th e heat transfer characteristics were clarified for the effects of the initial water height, the initial height of woking medium liquid layer and the inlet coolant temperature.

  1. Apparatus for detecting alpha radiation in difficult access areas

    DOEpatents

    Steadman, P.; MacArthur, D.W.

    1997-09-02

    An electrostatic alpha radiation detector for measuring alpha radiation emitted from inside an enclosure comprising an electrically conductive expandable electrode for insertion into the enclosure is disclosed. After insertion, the electrically conductive expandable electrode is insulated from the enclosure and defines a decay cavity between the electrically conductive expandable electrode and the enclosure so that air ions generated in the decay cavity are electrostatically captured by the electrically conductive expandable electrode and the enclosure when an electric potential is applied between the electrically conductive expandable electrode and the enclosure. Indicator means are attached to the electrically conductive expandable electrode for indicating an electrical current produced by generation of the air ions generated in the decay cavity by collisions between air molecules and the alpha particles emitted from the enclosure. A voltage source is connected between the indicator means and the electrically conductive enclosure for creating an electric field between the electrically conductive expandable electrode and the enclosure. 4 figs.

  2. [Diurnal and Seasonal Dynamic Variation of Soil Respiration and Its Influencing Factors of Different Fenced Enclosure Years in Desert Steppec].

    PubMed

    Cui, Hai; Zhang, Ya-hong

    2016-04-15

    The fenced measures could improve the ecological environment of degraded grassland, it's a main measure for restoration of degraded grassland vegetation in China. Soil respiration (Rs) is an important component of an ecosystem's carbon cycle and the main pathway for carbon moving from the ecosystem to the atmosphere. In order to explore soil respiration characteristics and influencing factors of the different fenced years in arid desert grassland, we continuously observed Rs rate and environmental factors in the growing season of fenced enclosure 11a, 7a and no fenced (CK) desert steppe in Ningxia. The results showed that: (1) Both the diurnal andseasonal variations of Rs rate showed a single asymmetric peak changing in fenced enclosure of 11 years, 7 years, CK desert steppe. On the daily scale, the maximum and minimum values of Rs rate were found in the periods of 12:00-16:00 and 00:00-06:00,respectively. On the seasonal variation scale, the maximum value of Rs rate occurred in August with suitable precipitation and temperature conditions. And the Rs rate of the growing season of different fenced enclosure years was in the order of 11a [0.143 g · (m² · h)⁻¹] > 7a [0.138 g · (m² · h)⁻¹] > CK [0.106 g · (m2 - h)⁻¹]. (2) According to statistical analysis, it indicated that R² rate had a significant exponential positive relationship with air and soil temperature in fenced enclosure of 11 years, 7 years, CK desert steppe (P < 0.01). The order of the correlation of Rs rate and temperature was shown as soil surface temperature (R²: 0.408-0.413) > air temperature (R2: 0.355-0.376) > 5-20 cm soil temperature (R2: 0.263-0.394). The temperature sensitivity coefficient Q, increased gradually with the soil depth, and Q1, of different fenced enclosure years was showed as 11 a (2.728) > 7a (2.436) > CK (2.086). (3) A significant quadratic function model (P < 0.05) was observed for the relationship between Rs rate and relative air humidity, soil moisture content of fenced enclosure 11a, 7a and CK desert steppe in the whole growing season. Rs rate had a significant linear negative correlation with air carbon dioxide concentration (P < 0.01), a linear positive correlation with the windspeed (P < 0.05), and a significant weak linear positive correlation with light intensity (P < 0.01). (4) It showed that Rs increasedwith increasing fenced closure years in arid desert steppe, and temperature sensitivity coefficient Q₁₀ also increased with increasing fenced enclosure years. To sum up, 0-20 cm soil temperature and moisture were the main influencing factors of soil respiration of desert steppe. This study has important implications to understand the role that different fenced enclosure years play in carbon emission. Such information will lay a foundation for assessing carbon source or carbon sequestration of different fenced enclosure years in desert steppe. Therefore, our research results have important function for better managing grassland in desert steppe in Ningxia and other arid and semiarid areas of North China.

  3. Method of making a quartz resonator

    DOEpatents

    Vig, John R.; Filler, Raymond L.; Peters, R. Donald; Frank, James M.

    1981-01-01

    A quartz resonator is made from a chemically polished quartz plate. The plate is placed in an enclosure fitted with at least three mounting clips to receive the plate. The plate is secured to the clips with an electrically conductive adhesive capable of withstanding operation at 350 degrees C. The assembly is cleaned and a metallic electrode deposited onto the plate until the desired frequency is reached. The enclosure is then hermetically sealed. The resulting resonator can consistently withstand extremely high shocks.

  4. Diesel engine exhaust oxidizer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kammel, R.A.

    1992-06-16

    This patent describes a diesel engine exhaust oxidizing device. It comprises: an enclosure having an inlet for receiving diesel engine exhaust, a main flow path through the enclosure to an outlet of the enclosure, a by-ass through the enclosure, and a microprocessor control means.

  5. Evidence of a relational spatial strategy in learning the centre of enclosures in human children (Homo sapiens).

    PubMed

    Tommasi, Luca; Giuliano, Alda

    2014-07-01

    Three- to five-year-old children were trained to localize a sensor hidden underneath the floor, in the centre of a square-shaped enclosure (1.5m×1.5m). Walking over the sensor caused a pleasant music to be played in the environment, thus engaging children in a playful spatial search. Children easily learned to find the centre of the training environment starting from random positions. After training, children were tested in enclosures of different size and/or shape: a larger square-shaped enclosure (3m×3m), a rectangle-shaped enclosure (1.5m×3m), an equilateral triangle-shaped enclosure (side 3m) and an isosceles triangle-shaped enclosure (base 1.5m; sides 3m). Children searched in the central region of the enclosures, their precision varying as a function of the similarity of the testing enclosure's shape to the shape of the training enclosure. This suggests that a relational spatial strategy was used, and that it depended on the encoding of geometrical shape. This result highlights a distinctive role of the geometric centre of enclosed spaces in place learning in children, as already observed in nonhuman species. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Motifs for molecular recognition exploiting hydrophobic enclosure in protein-ligand binding.

    PubMed

    Young, Tom; Abel, Robert; Kim, Byungchan; Berne, Bruce J; Friesner, Richard A

    2007-01-16

    The thermodynamic properties and phase behavior of water in confined regions can vary significantly from that observed in the bulk. This is particularly true for systems in which the confinement is on the molecular-length scale. In this study, we use molecular dynamics simulations and a powerful solvent analysis technique based on inhomogenous solvation theory to investigate the properties of water molecules that solvate the confined regions of protein active sites. Our simulations and analysis indicate that the solvation of protein active sites that are characterized by hydrophobic enclosure and correlated hydrogen bonds induce atypical entropic and enthalpic penalties of hydration. These penalties apparently stabilize the protein-ligand complex with respect to the independently solvated ligand and protein, which leads to enhanced binding affinities. Our analysis elucidates several challenging cases, including the super affinity of the streptavidin-biotin system.

  7. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  8. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  9. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  10. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  11. 30 CFR 56.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  12. Track plate enclosures: Box designs affecting attractiveness to riparian mammals

    USGS Publications Warehouse

    Loukmas, J.J.; Mayack, D.T.; Richmond, M.E.

    2003-01-01

    We examined the efficacy of four track plate enclosure designs for monitoring the abundance of small and medium-sized mammals along 10 streams in New York State. Box size and clarity of view through the box were evaluated as factors affecting visitation. We checked track plate stations weekly from September 1999 to March 2000. Eleven mammalian species or species groups visited the track plate stations. Raccoons (Procyon lotor) (P = 0.020) and feral cats (Felis catus) (P = 0.008) visited large enclosures significantly more than small enclosures. Feral cats visited clear-view enclosures significantly more than obstructed-view enclosures (P = 0.025). Enclosure size and view did not significantly affect visitation by other species; however, a large box with a clear view was the most effective design.

  13. Selective control of toxic Microcystis water blooms using lysine and malonic acid: an enclosure experiment.

    PubMed

    Kaya, Kunimitsu; Liu, Yong-Ding; Shen, Yin-Wu; Xiao, Bang-Ding; Sano, Tomoharu

    2005-04-01

    Three enclosures (10 x 10 x 1.5-1.3 m in depth) were set beside Dianch Lake, Kunming, People's Republic of China, for the period from July 28 to August 26, 2002. The enclosures were filled with cyanobacterial (Microcystis aeruginosa) water bloom-containing lake water. Lake sediment that contained macrophytes and water chestnut seeds was spread over the entire bottom of each enclosure. Initially, 10 g/m(2) of lysine was sprayed in Enclosure B, and 10 g/m(2) each of lysine and malonic acid were sprayed together in Enclosure C. Enclosure A remained untreated and was used as a control. The concentrations of lysine, malonic acid, chlorophyll a, and microcystin as well as the cell numbers of phytoplankton such as cyanobacteria, diatom, and euglena were monitored. On day 1 of the treatment, formation of cyanobacterial blooms almost ceased in Enclosures B and C, although Microcystis cells in the control still formed blooms. On day 7 Microcystis cells in Enclosure B that had been treated with lysine started growing again, whereas growth was not observed in Microcystis cells in Enclosure C, which had been treated with lysine and malonic acid. On day 28 the surface of Enclosure B was covered with water chestnut (Trapa spp.) and the Microcystis blooms again increased. In contrast, growth of macrophytes (Myriophllum spicatum and Potamogeton crispus) was observed in Enclosure C; however, no cyanobacterial blooms were observed. Lysine and malonic acid had completely decomposed. The microcystin concentration on day 28 decreased to 25% of the initial value, and the pH shifted from the initial value of 9.2 to 7.8. We concluded that combined treatment with lysine and malonic acid selectively controlled toxic Microcystis water blooms and induced the growth of macrophytes.

  14. Next Generation Trusted Radiation Identification System (NG-TRIS).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flynn, Adam J.; Amai, Wendy A.; Merkle, Peter Benedict

    2010-05-01

    The original Trusted Radiation Identification System (TRIS) was developed from 1999-2001, featuring information barrier technology to collect gamma radiation template measurements useful for arms control regime operations. The first TRIS design relied upon a multichannel analyzer (MCA) that was external to the protected volume of the system enclosure, undesirable from a system security perspective. An internal complex programmable logic device (CPLD) contained data which was not subject to software authentication. Physical authentication of the TRIS instrument case was performed by a sensitive but slow eddy-current inspection method. This paper describes progress to date for the Next Generation TRIS (NG-TRIS), whichmore » improves the TRIS design. We have incorporated the MCA internal to the trusted system volume, achieved full authentication of CPLD data, and have devised rapid methods to authenticate the system enclosure and weld seals of the NG-TRIS enclosure. For a complete discussion of the TRIS system and components upon which NG-TRIS is based, the reader is directed to the comprehensive user's manual and system reference of Seager, et al.« less

  15. 46 CFR 111.50-7 - Enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Enclosures. 111.50-7 Section 111.50-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-7 Enclosures. (a) Each enclosure of an overcurrent protective...

  16. 46 CFR 111.40-5 - Enclosure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Enclosure. 111.40-5 Section 111.40-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-5 Enclosure. Each panelboard must have a noncombustible enclosure that meets...

  17. 46 CFR 111.40-5 - Enclosure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Enclosure. 111.40-5 Section 111.40-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-5 Enclosure. Each panelboard must have a noncombustible enclosure that meets...

  18. 46 CFR 111.50-7 - Enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Enclosures. 111.50-7 Section 111.50-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-7 Enclosures. (a) Each enclosure of an overcurrent protective...

  19. 46 CFR 111.40-5 - Enclosure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Enclosure. 111.40-5 Section 111.40-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-5 Enclosure. Each panelboard must have a noncombustible enclosure that meets...

  20. 46 CFR 111.40-5 - Enclosure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Enclosure. 111.40-5 Section 111.40-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-5 Enclosure. Each panelboard must have a noncombustible enclosure that meets...

  1. 46 CFR 111.50-7 - Enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Enclosures. 111.50-7 Section 111.50-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-7 Enclosures. (a) Each enclosure of an overcurrent protective...

  2. 46 CFR 111.40-5 - Enclosure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Enclosure. 111.40-5 Section 111.40-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-5 Enclosure. Each panelboard must have a noncombustible enclosure that meets...

  3. 46 CFR 111.50-7 - Enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Enclosures. 111.50-7 Section 111.50-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-7 Enclosures. (a) Each enclosure of an overcurrent protective...

  4. 9 CFR 3.28 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.28 Primary enclosures. All primary enclosures for guinea pigs and hamsters shall conform to the following requirements: (a) General. (1) Primary enclosures shall be structurally sound and maintained in good repair to protect the guinea pigs and hamsters...

  5. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  6. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  7. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  8. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  9. 30 CFR 57.12068 - Locking transformer enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  10. 9 CFR 3.28 - Primary enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Pigs and Hamsters Facilities and Operating Standards § 3.28 Primary enclosures. All primary enclosures for guinea pigs and hamsters shall conform to the following requirements: (a) General. (1) Primary enclosures shall be structurally sound and maintained in good repair to protect the guinea pigs and hamsters...

  11. VLT enclosures: design and construction

    NASA Astrophysics Data System (ADS)

    Schneermann, Michael W.; Marchiori, Gianpietro; Dimichino, Francesco

    1997-03-01

    The VLT enclosures main functions are to protect the telescopes during operational as well as non-operational phases from any adverse weather conditions and to provide optimal conditions for observation. An adequate design of a ventilation and wind protection system is important for the performance of the enclosures with respect to the minimization of the corresponding seeing effects. The VLT enclosures are equipped with ventilation doors on the azimuth platform level, with louvers on the rotating part and with a windscreen at the observing slit. Extensive qualification tests of the louvers and windscreen mechanical assemblies have been performed during the enclosures development phase. This paper gives an overview over the general layout of the enclosures and the major subsystems, summarizes the main functional specifications and gives the main results and conclusions of the functional performance tests. Presently the first enclosure erection is nearing its completion and pre- commissioning of all systems will commence. The status of the site erection of the enclosures is presented and the planning for the next phases of the erection is presented.

  12. 30 CFR 75.819 - Motor-starter enclosures; barriers and interlocks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Motor-starter enclosures; barriers and...-Voltage Distribution High-Voltage Longwalls § 75.819 Motor-starter enclosures; barriers and interlocks. Compartment separation and cover interlock switches for motor-starter enclosures must be maintained in...

  13. 40 CFR 86.1217-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Obtain another small cylinder that has been charged with pure methanol if the system will be used for... Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1217-96 Evaporative emission enclosure... determination of enclosure background emissions (hydrocarbons and methanol); initial determination of enclosure...

  14. 40 CFR 86.1217-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Obtain another small cylinder that has been charged with pure methanol if the system will be used for... Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.1217-96 Evaporative emission enclosure... determination of enclosure background emissions (hydrocarbons and methanol); initial determination of enclosure...

  15. Design of a hybrid emissivity domestic electric oven

    NASA Astrophysics Data System (ADS)

    Isik, Ozgur; Onbasioglu, Seyhan Uygur

    2017-10-01

    In this study, the radiative properties of the surfaces of an electric oven were investigated. Using experimental data related to an oven-like enclosure, a novel combination of surface properties was developed. Three different surface emissivity combinations were analysed experimentally: low-emissivity, high emissivity (black-coated), and hybrid emissivity. The term "hybrid emissivity design" here corresponds to an enclosure with some high emissive and some low-emissive surfaces. The experiments were carried out according to the EN 50304 standard. When a brick (load) was placed in the enclosure, the view factors between its surfaces were calculated with the Monte Carlo method. These and the measured surface temperatures were then used to calculate the radiative heat fluxes on the surfaces of the load. The three different models were compared with respect to energy consumption and baking time. The hybrid model performed best, with the highest radiative heat transfer between the surfaces of the enclosure and the load and minimum heat loss from the cavity. Thus, it was the most efficient model with the lowest energy consumption and the shortest baking time. The recent European Union regulation regarding the energy labelling of domestic ovens was used.

  16. 50 CFR 14.121 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Wild Mammals and Birds to the United States Specifications for Nonhuman Primates § 14.121 Primary enclosures. (a) No more than one primate shall be transported in a primary enclosure. However, a mother and... animals that have been habitually housed together may be shipped in the same primary enclosure. Primates...

  17. 50 CFR 14.121 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Wild Mammals and Birds to the United States Specifications for Nonhuman Primates § 14.121 Primary enclosures. (a) No more than one primate shall be transported in a primary enclosure. However, a mother and... animals that have been habitually housed together may be shipped in the same primary enclosure. Primates...

  18. High-performance rechargeable batteries with fast solid-state ion conductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farmer, Joseph C.

    A high-performance rechargeable battery using ultra-fast ion conductors. In one embodiment the rechargeable battery apparatus includes an enclosure, a first electrode operatively connected to the enclosure, a second electrode operatively connected to the enclosure, a nanomaterial in the enclosure, and a heat transfer unit.

  19. Modeling of influencing parameters in active noise control on an enclosure wall

    NASA Astrophysics Data System (ADS)

    Tarabini, Marco; Roure, Alain

    2008-04-01

    This paper investigates, by means of a numerical model, the possibility of using an active noise barrier to virtually reduce the acoustic transparency of a partition wall inside an enclosure. The room is modeled with the image method as a rectangular enclosure with a stationary point source; the active barrier is set up by an array of loudspeakers and error microphones and is meant to minimize the squared sound pressure on a wall with the use of a decentralized control. Simulations investigate the effects of the enclosure characteristics and of the barrier geometric parameters on the sound pressure attenuation on the controlled partition, on the whole enclosure potential energy and on the diagonal control stability. Performances are analyzed in a frequency range of 25-300 Hz at discrete 25 Hz steps. Influencing parameters and their effects on the system performances are identified with a statistical inference procedure. Simulation results have shown that it is possible to averagely reduce the sound pressure on the controlled partition. In the investigated configuration, the surface attenuation and the diagonal control stability are mainly driven by the distance between the loudspeakers and the error microphones and by the loudspeakers directivity; minor effects are due to the distance between the error microphones and the wall, by the wall reflectivity and by the active barrier grid meshing. Room dimensions and source position have negligible effects. Experimental results point out the validity of the model and the efficiency of the barrier in the reduction of the wall acoustic transparency.

  20. Improved algorithms and methods for room sound-field prediction by acoustical radiosity in arbitrary polyhedral rooms.

    PubMed

    Nosal, Eva-Marie; Hodgson, Murray; Ashdown, Ian

    2004-08-01

    This paper explores acoustical (or time-dependent) radiosity--a geometrical-acoustics sound-field prediction method that assumes diffuse surface reflection. The literature of acoustical radiosity is briefly reviewed and the advantages and disadvantages of the method are discussed. A discrete form of the integral equation that results from meshing the enclosure boundaries into patches is presented and used in a discrete-time algorithm. Furthermore, an averaging technique is used to reduce computational requirements. To generalize to nonrectangular rooms, a spherical-triangle method is proposed as a means of evaluating the integrals over solid angles that appear in the discrete form of the integral equation. The evaluation of form factors, which also appear in the numerical solution, is discussed for rectangular and nonrectangular rooms. This algorithm and associated methods are validated by comparison of the steady-state predictions for a spherical enclosure to analytical solutions.

  1. Improved algorithms and methods for room sound-field prediction by acoustical radiosity in arbitrary polyhedral rooms

    NASA Astrophysics Data System (ADS)

    Nosal, Eva-Marie; Hodgson, Murray; Ashdown, Ian

    2004-08-01

    This paper explores acoustical (or time-dependent) radiosity-a geometrical-acoustics sound-field prediction method that assumes diffuse surface reflection. The literature of acoustical radiosity is briefly reviewed and the advantages and disadvantages of the method are discussed. A discrete form of the integral equation that results from meshing the enclosure boundaries into patches is presented and used in a discrete-time algorithm. Furthermore, an averaging technique is used to reduce computational requirements. To generalize to nonrectangular rooms, a spherical-triangle method is proposed as a means of evaluating the integrals over solid angles that appear in the discrete form of the integral equation. The evaluation of form factors, which also appear in the numerical solution, is discussed for rectangular and nonrectangular rooms. This algorithm and associated methods are validated by comparison of the steady-state predictions for a spherical enclosure to analytical solutions.

  2. A combined finite element-boundary element formulation for solution of two-dimensional problems via CGFFT

    NASA Technical Reports Server (NTRS)

    Collins, Jeffery D.; Jin, Jian-Ming; Volakis, John L.

    1990-01-01

    A method for the computation of electromagnetic scattering from arbitrary two-dimensional bodies is presented. The method combines the finite element and boundary element methods leading to a system for solution via the conjugate gradient Fast Fourier Transform (FFT) algorithm. Two forms of boundaries aimed at reducing the storage requirement of the boundary integral are investigated. It is shown that the boundary integral becomes convolutional when a circular enclosure is chosen, resulting in reduced storage requirement when the system is solved via the conjugate gradient FFT method. The same holds for the ogival enclosure, except that some of the boundary integrals are not convolutional and must be carefully treated to maintain O(N) memory requirement. Results for several circular and ogival structures are presented and shown to be in excellent agreement with those obtained by traditional methods.

  3. Event counting alpha detector

    DOEpatents

    Bolton, Richard D.; MacArthur, Duncan W.

    1996-01-01

    An electrostatic detector for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure.

  4. Event counting alpha detector

    DOEpatents

    Bolton, R.D.; MacArthur, D.W.

    1996-08-27

    An electrostatic detector is disclosed for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure. 6 figs.

  5. Thermal actuation of extinguishing systems

    NASA Astrophysics Data System (ADS)

    Evans, D. D.

    1984-03-01

    A brief review of the Response Time Index (RTI) method of characterizing the thermal response of commercial sprinklers and heat detectors is presented. Measured ceiling layer flow temperature and velocity histories from a bedroom fire test are used to illustrate the use of RTI in calculating sprinkler operation times. In small enclosure fires, a quiescent warm gas layer confined by the room walls may accumulate below the ceiling before sprinkler operation. The effects of this warm gas layer on the fire plume and ceiling jet flows are accounted for by substitution of an equivalent point source fire. Encouraging agreement was found between measured ceiling jet temperatures from steady fires in a laboratory scale cylindrical enclosure put into dimensionless form based on parameters of the substitute fire source, and existing empirical correlations from fire tests in large enclosures in which a quiescent warm upper gas layer does not accumulate.

  6. Multi-color pyrometry imaging system and method of operating the same

    DOEpatents

    Estevadeordal, Jordi; Nirmalan, Nirm Velumylum; Tralshawala, Nilesh; Bailey, Jeremy Clyde

    2017-03-21

    A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

  7. Integrated optical biosensor system (IOBS)

    DOEpatents

    Grace, Karen M.; Sweet, Martin R.; Goeller, Roy M.; Morrison, Leland Jean; Grace, Wynne Kevin; Kolar, Jerome D.

    2007-10-30

    An optical biosensor has a first enclosure with a pathogen recognition surface, including a planar optical waveguide and grating located in the first enclosure. An aperture is in the first enclosure for insertion of sample to be investigated to a position in close proximity to the pathogen recognition surface. A laser in the first enclosure includes means for aligning and means for modulating the laser, the laser having its light output directed toward said grating. Detection means are located in the first enclosure and in optical communication with the pathogen recognition surface for detecting pathogens after interrogation by the laser light and outputting the detection. Electronic means is located in the first enclosure and receives the detection for processing the detection and outputting information on the detection, and an electrical power supply is located in the first enclosure for supplying power to the laser, the detection means and the electronic means.

  8. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides amore » simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.« less

  9. 9 CFR 3.61 - Primary enclosures used to transport live rabbits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Primary enclosures used to transport... and Transportation of Rabbits Transportation Standards § 3.61 Primary enclosures used to transport... transport in commerce any live rabbit in a primary enclosure that does not conform to the following...

  10. 9 CFR 3.61 - Primary enclosures used to transport live rabbits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary enclosures used to transport... and Transportation of Rabbits Transportation Standards § 3.61 Primary enclosures used to transport... transport in commerce any live rabbit in a primary enclosure that does not conform to the following...

  11. 40 CFR 63.924 - Standards-Container Level 3 controls.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... selected by the owner or operator: (1) The enclosure shall be designed and operated in accordance with the criteria for a permanent total enclosure as specified in “Procedure T—Criteria for and Verification of a... enclosure. The owner or operator shall perform the verification procedure for the enclosure as specified in...

  12. 40 CFR 63.924 - Standards-Container Level 3 controls.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... selected by the owner or operator: (1) The enclosure shall be designed and operated in accordance with the criteria for a permanent total enclosure as specified in “Procedure T—Criteria for and Verification of a... enclosure. The owner or operator shall perform the verification procedure for the enclosure as specified in...

  13. Linear diffusion into a Faraday cage.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warne, Larry Kevin; Lin, Yau Tang; Merewether, Kimball O.

    2011-11-01

    Linear lightning diffusion into a Faraday cage is studied. An early-time integral valid for large ratios of enclosure size to enclosure thickness and small relative permeability ({mu}/{mu}{sub 0} {le} 10) is used for this study. Existing solutions for nearby lightning impulse responses of electrically thick-wall enclosures are refined and extended to calculate the nearby lightning magnetic field (H) and time-derivative magnetic field (HDOT) inside enclosures of varying thickness caused by a decaying exponential excitation. For a direct strike scenario, the early-time integral for a worst-case line source outside the enclosure caused by an impulse is simplified and numerically integrated tomore » give the interior H and HDOT at the location closest to the source as well as a function of distance from the source. H and HDOT enclosure response functions for decaying exponentials are considered for an enclosure wall of any thickness. Simple formulas are derived to provide a description of enclosure interior H and HDOT as well. Direct strike voltage and current bounds for a single-turn optimally-coupled loop for all three waveforms are also given.« less

  14. Brief flight to a familiar enclosure in response to a conditional stimulus in rats.

    PubMed

    de Oca, Beatrice M; Minor, Thomas R; Fanselow, Michael S

    2007-04-01

    The authors observed brief, directed movement to a familiar enclosure in rats to determine whether this behavior is part of a rat's defensive repertoire when exposed to a conditional-fear stimulus. In Experiment 1, upon exposure to the compound conditional-fear stimulus of tone and light, only rats that received paired presentations of the conditional stimuli and shock fled into a small, familiar enclosure where they then froze. Rats that had received unpaired presentations did not enter the enclosure in significant amounts when later tested. In Experiment 2, the authors observed rats' freezing and use of either a familiar or an unfamiliar enclosure when tested with a conditional-fear stimulus. Rats tested with a familiar enclosure entered it more quickly than did rats without prior exposure to the enclosure. Freezing was greatest when both training and testing environments were similar with respect to access to the enclosure. The results of these 2 experiments support the idea that brief, directed flight in rats is a component of the postencounter stage of predatory imminence (M. S. Fanselow & L. S. Lester, 1988) and is compatible with freezing.

  15. Structural Assessment of Tungsten-Epoxy Bonding in Spacecraft Composite Enclosures with Enhanced Radiation Protection

    NASA Astrophysics Data System (ADS)

    Kanerva, M.; Koerselman, J. R.; Revitzer, H.; Johansson, L.-S.; Sarlin, E.; Rautiainen, A.; Brander, T.; Saarela, O.

    2014-06-01

    Spacecraft include sensitive electronics that must be protected against radiation from the space environment. Hybrid laminates consisting of tungsten layers and carbon- fibre-reinforced epoxy composite are a potential solution for lightweight, efficient, and protective enclosure material. Here, we analysed six different surface treatments for tungsten foils in terms of the resulting surface tension components, composition, and bonding strength with epoxy. A hydrofluoric-nitric-sulfuric-acid method and a diamond-like carbon-based DIARC® coating were found the most potential surface treatments for tungsten foils in this study.

  16. High-performance rechargeable batteries with nanoparticle active materials, photochemically regenerable active materials, and fast solid-state ion conductors

    DOEpatents

    Farmer, Joseph C.

    2017-04-04

    A high-performance rechargeable battery using ultra-fast ion conductors. In one embodiment the rechargeable battery apparatus includes an enclosure, a first electrode operatively connected to the enclosure, a second electrode operatively connected to the enclosure, a nanomaterial in the enclosure, and a heat transfer unit.

  17. A combined finite element-boundary element formulation for solution of axially symmetric bodies

    NASA Technical Reports Server (NTRS)

    Collins, Jeffrey D.; Volakis, John L.

    1991-01-01

    A new method is presented for the computation of electromagnetic scattering from axially symmetric bodies. To allow the simulation of inhomogeneous cross sections, the method combines the finite element and boundary element techniques. Interior to a fictitious surface enclosing the scattering body, the finite element method is used which results in a sparce submatrix, whereas along the enclosure the Stratton-Chu integral equation is enforced. By choosing the fictitious enclosure to be a right circular cylinder, most of the resulting boundary integrals are convolutional and may therefore be evaluated via the FFT with which the system is iteratively solved. In view of the sparce matrix associated with the interior fields, this reduces the storage requirement of the entire system to O(N) making the method attractive for large scale computations. The details of the corresponding formulation and its numerical implementation are described.

  18. Lightning vulnerability of fiber-optic cables.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Leonard E.; Caldwell, Michele

    2008-06-01

    One reason to use optical fibers to transmit data is for isolation from unintended electrical energy. Using fiber optics in an application where the fiber cable/system penetrates the aperture of a grounded enclosure serves two purposes: first, it allows for control signals to be transmitted where they are required, and second, the insulating properties of the fiber system help to electrically isolate the fiber terminations on the inside of the grounded enclosure. A fundamental question is whether fiber optic cables can allow electrical energy to pass through a grounded enclosure, with a lightning strike representing an extreme but very importantmore » case. A DC test bed capable of producing voltages up to 200 kV was used to characterize electrical properties of a variety of fiber optic cable samples. Leakage current in the samples were measured with a micro-Ammeter. In addition to the leakage current measurements, samples were also tested to DC voltage breakdown. After the fiber optic cables samples were tested with DC methods, they were tested under representative lightning conditions at the Sandia Lightning Simulator (SLS). Simulated lightning currents of 30 kA and 200 kA were selected for this test series. This paper documents measurement methods and test results for DC high voltage and simulated lightning tests performed at the Sandia Lightning Simulator on fiber optic cables. The tests performed at the SLS evaluated whether electrical energy can be conducted inside or along the surface of a fiber optic cable into a grounded enclosure under representative lightning conditions.« less

  19. Alpha-environmental continuous air monitor inlet

    DOEpatents

    Rodgers, John C.

    2003-01-01

    A wind deceleration and protective shroud that provides representative samples of ambient aerosols to an environmental continuous air monitor (ECAM) has a cylindrical enclosure mounted to an input on the continuous air monitor, the cylindrical enclosure having shrouded nozzles located radially about its periphery. Ambient air flows, often along with rainwater flows into the nozzles in a sampling flow generated by a pump in the continuous air monitor. The sampling flow of air creates a cyclonic flow in the enclosure that flows up through the cylindrical enclosure until the flow of air reaches the top of the cylindrical enclosure and then is directed downward to the continuous air monitor. A sloped platform located inside the cylindrical enclosure supports the nozzles and causes any moisture entering through the nozzle to drain out through the nozzles.

  20. Calculated wind noise for an infrasonic wind noise enclosure.

    PubMed

    Abbott, JohnPaul; Raspet, Richard

    2015-07-01

    A simple calculation of the wind noise measured at the center of a large porous wind fence enclosure is developed. The calculation provides a good model of the measured wind noise, with a good agreement within ±5 dB, and is derived by combining the wind noise contributions from (a) the turbulence-turbulence and turbulence-shear interactions inside the enclosure, (b) the turbulence interactions on the surface of the enclosure, and (c) the turbulence-shear interactions outside of the enclosure. Each wind noise contribution is calculated from the appropriate measured turbulence spectra, velocity profiles, correlation lengths, and the mean velocity at the center, surface, and outside of the enclosure. The model is verified by comparisons of the measured wind noise to the calculated estimates of the differing noise contributions and their sum.

  1. Electrical bushing for a superconductor element

    DOEpatents

    Mirebeau, Pierre; Lallouet, Nicolas; Delplace, Sebastien; Lapierre, Regis

    2010-05-04

    The invention relates to an electrical bushing serving to make a connection at ambient temperature to a superconductor element situated in an enclosure at cryogenic temperature. The electrical bushing passes successively through an enclosure at intermediate temperature between ambient temperature and cryogenic temperature, and an enclosure at ambient temperature, and it comprises a central electrical conductor surrounded by an electrically insulating sheath. According to the invention, an electrically conductive screen connected to ground potential surrounds the insulating sheath over a section that extends from the end of the bushing that is in contact with the enclosure at cryogenic temperature at least as far as the junction between the enclosure at intermediate temperature and the enclosure at ambient temperature. The invention is more particularly applicable to making a connection to a superconductor cable.

  2. Voltage verification unit

    DOEpatents

    Martin, Edward J [Virginia Beach, VA

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  3. Freeze-tolerant condenser for a closed-loop heat-transfer system

    NASA Technical Reports Server (NTRS)

    Crowley, Christopher J. (Inventor); Elkouh, Nabil A. (Inventor)

    2002-01-01

    A freeze tolerant condenser (106) for a two-phase heat transfer system is disclosed. The condenser includes an enclosure (110) and a porous artery (112) located within and extending along the length of the enclosure. A vapor space (116) is defined between the enclosure and the artery, and a liquid space (114) is defined by a central passageway within the artery. The artery includes a plurality of laser-micromachined capillaries (130) extending from the outer surface of the artery to its inner surface such that the vapor space is in fluid communication with the liquid space. In one embodiment of the invention, the capillaries (130) are cylindrical holes having a diameter of no greater than 50 microns. In another embodiment, the capillaries (130') are slots having widths of no greater than 50 microns. A method of making an artery in accordance with the present invention is also disclosed. The method includes providing a solid-walled tube and laser-micromachining a plurality of capillaries into the tube along a longitudinal axis, wherein each capillary has at least one cross-sectional dimension transverse to the longitudinal axis of less than 50 microns.

  4. An electromagnetic induced transparency-like scheme for wireless power transfer using dielectric resonators

    NASA Astrophysics Data System (ADS)

    Elnaggar, Sameh Y.

    2017-02-01

    Similar to the hybridization of three atoms, three coupled resonators interact to form bonding, anti-bonding, and non-bonding modes. The non-bonding mode enables an electromagnetic induced transparency like transfer of energy. Here, the non-bonding mode, resulting from the strong electric coupling of two dielectric resonators and an enclosure, is exploited to show that it is feasible to transfer power over a distance comparable to the operating wavelength. In this scheme, the enclosure acts as a mediator. The strong coupling permits the excitation of the non-bonding mode with high purity. This approach is different from resonant inductive coupling, which works in the sub-wavelength regime. Optimal loads and the corresponding maximum efficiency are determined using two independent methods: Coupled Mode Theory and Circuit modelling. It is shown that, unlike resonant inductive coupling, the figure of merit depends on the enclosure quality and not on the load, which emphasizes the role of the enclosure as a mediator. Briefly after the input excitation is turned on, the energy in the receiver builds up via all coupled and spurious modes. As time elapses, all modes except the non-bonding cease to sustain. Due to the strong coupling between the dielectrics and the enclosure, such systems have unique properties such as high and uniform efficiency over large distances and minimal fringing fields. These properties suggest that electromagnetic induced transparency like schemes that rely on the use of dielectric resonators can be used to power autonomous systems inside an enclosure or find applications when exposure to the fields needs to be minimal. Finite Element computations are used to verify the theoretical predictions by determining the transfer efficiency, field profile, and coupling coefficients for two different systems. It is shown that the three resonators must be present for efficient power transfer; if one or more are removed, the transfer efficiency reduces significantly.

  5. Borehole sounding device with sealed depth and water level sensors

    DOEpatents

    Skalski, Joseph C.; Henke, Michael D.

    2005-08-02

    A borehole device having proximal and distal ends comprises an enclosure at the proximal end for accepting an aircraft cable containing a plurality of insulated conductors from a remote position. A water sensing enclosure is sealingly attached to the enclosure and contains means for detecting water, and sending a signal on the cable to the remote position indicating water has been detected. A bottom sensing enclosure is sealingly attached to the water sensing enclosure for determining when the borehole device encounters borehole bottom and sends a signal on the cable to the remote position indicating that borehole bottom has been encountered.

  6. Fogging formulations for fixation of particulate contamination in ductwork and enclosures

    DOEpatents

    Maresca, Jr., Joseph W.; Kostelnik, Lori M.; Kriskivich, James R.; Demmer, Rick L.; Tripp, Julia L.

    2015-09-08

    A method and an apparatus using aqueous fixatives for fogging of ventilation ductwork, enclosures, or buildings containing dust, lint, and particulates that may be contaminated by radionuclides and other dangerous or unsafe particulate contaminants, which method and apparatus are capable of (1) obtaining full coverage within the ductwork and (2) penetrating and fixing the lint, dust and large particles present in the ductwork so that no airborne particles are released during or after the application of the fixative. New aqueous fogging solutions outperform conventional glycerin-based solutions. These aqueous solutions will fog using conventional methods of application and contain a surfactant to aid wetting and penetration of the lint and dust, a binder to stabilize loose or respirable particles, and an agent to aid in fogging and enhance adhesiveness. The solutions are safe and easy to use.

  7. Glove port retrofit assembly and method of replacing components

    DOEpatents

    Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

    2014-11-18

    What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

  8. 40 CFR 63.5875 - How do I determine the capture efficiency of the enclosure on my wet-out area and the capture...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... efficiency of the enclosure on my wet-out area and the capture efficiency of my oven(s) for continuous... efficiency of the enclosure on my wet-out area and the capture efficiency of my oven(s) for continuous lamination/casting operations? (a) The capture efficiency of a wet-out area enclosure is assumed to be 100...

  9. Gas venting system

    DOEpatents

    Khan, Amjad; Dreier, Ken Wayne; Moulthrop, Lawrence Clinton; White, Erik James

    2010-06-29

    A system to vent a moist gas stream is disclosed. The system includes an enclosure and an electrochemical cell disposed within the enclosure, the electrochemical cell productive of the moist gas stream. A first vent is in fluid communication with the electrochemical cell for venting the moist gas stream to an exterior of the enclosure, and a second vent is in fluid communication with an interior of the enclosure and in thermal communication with the first vent for discharging heated air to the exterior of the enclosure. At least a portion of the discharging heated air is for preventing freezing of the moist gas stream within the first vent.

  10. Biogenic emissions of volatile organic compounds from gorse (Ulex europaeus): Diurnal emission fluxes at Kelling Heath, England

    NASA Astrophysics Data System (ADS)

    Cao, X.-L.; Boissard, C.; Juan, A. J.; Hewitt, C. N.; Gallagher, M.

    1997-08-01

    Volatile organic compound (VOC) emission fluxes from Gorse (Ulex europaeus) were measured during May 30-31, 1995 at Kelling Heath in eastern England by using bag enclosure and gradient methods simultaneously. The enclosure measurements were made from branches at different stages of physiological development (flowering, after flowering, and mixed). Isoprene was found to represent 90% of the total VOC emissions, and its emission rates fluctuated from 6 ng (g dwt)-1 h-1 in the early morning to about 9700 ng(g dwt)-1 h-1 at midday. Averaged emission rates standardized to 20°C were 1625, 2120, and 3700 ng (g dwt)-1 h-1 for the new grown, "mixed," and flowering branch, respectively. Trans-ocimene and α-pinene were the main monoterpenes emitted and represented, on average, 47.6% and 36.9% of the total monoterpenes. Other monoterpenes, camphene, sabinene, β-pinene, myrcene, limonene and γ-terpinene, were positively identified but together represented less than 1.5% of the total VOC emissions from gorse. Maximum isoprene concentrations in air at the site were measured around midday at 2 m (174 parts per trillion by volume, or pptv) and 6 m (149 pptv), and minimum concentrations were measured during the night (8 pptv at both heights). Mean daytime α-pinene air concentrations of 141 and 60 pptv at 2 and 6 m height were determined, but trans-ocimene concentrations were less than the analytical detection limit (4 pptv), suggesting rapid chemical removal of this compound from air. The isoprene fluxes calculated by the micrometeorological gradient method showed a pattern similar to that of those calculated by the enclosure method, with isoprene emission rates maximum at midday (100 μg m-2 h-1) and not detectable during the nighttime. Assessment of the fraction of the site covered by gorse plants enabled an extrapolation of emission fluxes from the enclosure measurements. When averaged over the 2 day experiment, isoprene fluxes of 29.8 and 27.8 μg m-2 h-1 were obtained from the gradient and the enclosure extrapolation respectively. These isoprene fluxes to the atmosphere represented between 0.12% and 0.35% of the net assimilated carbon (as CO2) uptake rate for gorse.

  11. Persistence and biodegradation of kerosene in high-arctic intertidal sediment.

    PubMed

    Røberg, Stian; Stormo, Svein Kristian; Landfald, Bjarne

    2007-10-01

    A kerosene type hydrocarbon fraction (equivalent to 7 L m(-2)) was added to enclosures in the surface layer of high-arctic intertidal beach sediment. The experimental spill was repeated in two consecutive years in the period July-September. The rate and extent of hydrocarbon removal and the accompanying bacterial response were monitored for 79 days (2002) and 78 days (2003). The bulk of added kerosene, i.e. 94-98%, was lost from the upper 5 cm layer by putatively abiotic processes within 2 days and a residual fraction in the range 0.6-1.2mg per g dry sediment was stably retained. Concomitant addition of oleophilic fertilizer led to higher initial retention, as 24% of the kerosene remained after 2 days in the presence of a modified, cold-climate adapted version of the well-known Inipol EAP 22 bioremediation agent. In these enclosures, which showed an increase in hydrocarbon-degrader counts from 6.5 x 10(3) to 4.1 x 10(7) per g dry sediment within 8 days, a 17% contribution by biodegradation to subsequent hydrocarbon removal was estimated. Stimulation in hydrocarbon-degrader counts in fertilizer-alone control enclosures was indistinguishable from the stimulation observed with both kerosene and fertilizer present, suggesting that the dynamics in numbers of hydrocarbon-degrading bacteria was primarily impacted by the bioremediation agent.

  12. Totally confined explosive welding

    NASA Technical Reports Server (NTRS)

    Bement, L. J. (Inventor)

    1978-01-01

    The undesirable by-products of explosive welding are confined and the association noise is reduced by the use of a simple enclosure into which the explosive is placed and in which the explosion occurs. An infrangible enclosure is removably attached to one of the members to be bonded at the point directly opposite the bond area. An explosive is completely confined within the enclosure at a point in close proximity to the member to be bonded and a detonating means is attached to the explosive. The balance of the enclosure, not occupied by explosive, is filled with a shaped material which directs the explosive pressure toward the bond area. A detonator adaptor controls the expansion of the enclosure by the explosive force so that the enclosure at no point experiences a discontinuity in expansion which causes rupture. The use of the technique is practical in the restricted area of a space station.

  13. Feed gas contaminant control in ion transport membrane systems

    DOEpatents

    Carolan, Michael Francis [Allentown, PA; Minford, Eric [Laurys Station, PA; Waldron, William Emil [Whitehall, PA

    2009-07-07

    Ion transport membrane oxidation system comprising an enclosure having an interior and an interior surface, inlet piping having an internal surface and adapted to introduce a heated feed gas into the interior of the enclosure, and outlet piping adapted to withdraw a product gas from the interior of the enclosure; one or more planar ion transport membrane modules disposed in the interior of the enclosure, each membrane module comprising mixed metal oxide material; and a preheater adapted to heat a feed gas to provide the heated feed gas to the inlet piping, wherein the preheater comprises an interior surface. Any of the interior surfaces of the enclosure, the inlet piping, and the preheater may be lined with a copper-containing metal lining. Alternatively, any of the interior surfaces of the inlet piping and the preheater may be lined with a copper-containing metal lining and the enclosure may comprise copper.

  14. Vibrations and structureborne noise in space station

    NASA Technical Reports Server (NTRS)

    Vaicaitis, R.; Lyrintzis, C. S.; Bofilios, D. A.

    1987-01-01

    Analytical models were developed to predict vibrations and structureborne noise generation of cylindrical and rectangular acoustic enclosures. These models are then used to determine structural vibration levels and interior noise to random point input forces. The guidelines developed could provide preliminary information on acoustical and vibrational environments in space station habitability modules under orbital operations. The structural models include single wall monocoque shell, double wall shell, stiffened orthotropic shell, descretely stiffened flat panels, and a coupled system composed of a cantilever beam structure and a stiffened sidewall. Aluminum and fiber reinforced composite materials are considered for single and double wall shells. The end caps of the cylindrical enclosures are modeled either as single or double wall circular plates. Sound generation in the interior space is calculated by coupling the structural vibrations to the acoustic field in the enclosure. Modal methods and transfer matrix techniques are used to obtain structural vibrations. Parametric studies are performed to determine the sensitivity of interior noise environment to changes in input, geometric and structural conditions.

  15. Resistance, resilience and recovery: aquatic bacterial dynamics after water column disturbance.

    PubMed

    Shade, Ashley; Read, Jordan S; Welkie, David G; Kratz, Timothy K; Wu, Chin H; McMahon, Katherine D

    2011-10-01

    For lake microbes, water column mixing acts as a disturbance because it homogenizes thermal and chemical gradients known to define the distributions of microbial taxa. Our first objective was to isolate hypothesized drivers of lake bacterial response to water column mixing. To accomplish this, we designed an enclosure experiment with three treatments to independently test key biogeochemical changes induced by mixing: oxygen addition to the hypolimnion, nutrient addition to the epilimnion, and full water column mixing. We used molecular fingerprinting to observe bacterial community dynamics in the treatment and control enclosures, and in ambient lake water. We found that oxygen and nutrient amendments simulated the physical-chemical water column environment following mixing and resulted in similar bacterial communities to the mixing treatment, affirming that these were important drivers of community change. These results demonstrate that specific environmental changes can replicate broad disturbance effects on microbial communities. Our second objective was to characterize bacterial community stability by quantifying community resistance, recovery and resilience to an episodic disturbance. The communities in the nutrient and oxygen amendments changed quickly (had low resistance), but generally matched the control composition by the 10th day after treatment, exhibiting resilience. These results imply that aquatic bacterial assemblages are generally stable in the face of disturbance. © 2011 Society for Applied Microbiology and Blackwell Publishing Ltd.

  16. Non-destructive component separation using infrared radiant energy

    DOEpatents

    Simandl, Ronald F [Knoxville, TN; Russell, Steven W [Knoxville, TN; Holt, Jerrid S [Knoxville, TN; Brown, John D [Harriman, TN

    2011-03-01

    A method for separating a first component and a second component from one another at an adhesive bond interface between the first component and second component. Typically the method involves irradiating the first component with infrared radiation from a source that radiates substantially only short wavelengths until the adhesive bond is destabilized, and then separating the first component and the second component from one another. In some embodiments an assembly of components to be debonded is placed inside an enclosure and the assembly is illuminated from an IR source that is external to the enclosure. In some embodiments an assembly of components to be debonded is simultaneously irradiated by a multi-planar array of IR sources. Often the IR radiation is unidirectional. In some embodiments the IR radiation is narrow-band short wavelength infrared radiation.

  17. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  18. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  19. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  20. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  1. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  2. Analytical study of the liquid phase transient behavior of a high temperature heat pipe. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Roche, Gregory Lawrence

    1988-01-01

    The transient operation of the liquid phase of a high temperature heat pipe is studied. The study was conducted in support of advanced heat pipe applications that require reliable transport of high temperature drops and significant distances under a broad spectrum of operating conditions. The heat pipe configuration studied consists of a sealed cylindrical enclosure containing a capillary wick structure and sodium working fluid. The wick is an annular flow channel configuration formed between the enclosure interior wall and a concentric cylindrical tube of fine pore screen. The study approach is analytical through the solution of the governing equations. The energy equation is solved over the pipe wall and liquid region using the finite difference Peaceman-Rachford alternating direction implicit numerical method. The continuity and momentum equations are solved over the liquid region by the integral method. The energy equation and liquid dynamics equation are tightly coupled due to the phase change process at the liquid-vapor interface. A kinetic theory model is used to define the phase change process in terms of the temperature jump between the liquid-vapor surface and the bulk vapor. Extensive auxiliary relations, including sodium properties as functions of temperature, are used to close the analytical system. The solution procedure is implemented in a FORTRAN algorithm with some optimization features to take advantage of the IBM System/370 Model 3090 vectorization facility. The code was intended for coupling to a vapor phase algorithm so that the entire heat pipe problem could be solved. As a test of code capabilities, the vapor phase was approximated in a simple manner.

  3. 40 CFR 86.117-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and periodic determination of enclosure background emissions (hydrocarbons and methanol); initial determination of enclosure internal volume; and periodic hydrocarbon and methanol retention check and calibration. Methanol measurements may be omitted if methanol-fueled vehicles will not be tested in the...

  4. 40 CFR 86.117-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and periodic determination of enclosure background emissions (hydrocarbons and methanol); initial determination of enclosure internal volume; and periodic hydrocarbon and methanol retention check and calibration. Methanol measurements may be omitted if methanol-fueled vehicles will not be tested in the...

  5. Large fully retractable telescope enclosures still closable in strong wind

    NASA Astrophysics Data System (ADS)

    Bettonvil, Felix C. M.; Hammerschlag, Robert H.; Jägers, Aswin P. L.; Sliepen, Guus

    2008-07-01

    Two prototypes of fully retractable enclosures with diameters of 7 and 9 m have been built for the high-resolution solar telescopes DOT (Dutch Open Telescope) and GREGOR, both located at the Canary Islands. These enclosures protect the instruments for bad weather and are fully open when the telescopes are in operation. The telescopes and enclosures also operate in hard wind. The prototypes are based on tensioned membrane between movable but stiff bows, which fold together to a ring when opened. The height of the ring is small. The prototypes already survived several storms, with often snow and ice, without any damage, including hurricane Delta with wind speeds up to 68 m/s. The enclosures can still be closed and opened with wind speeds of 20 m/s without any problems or restrictions. The DOT successfully demonstrated the open, wind-flushing concept for astronomical telescopes. It is now widely recognized that also large future telescopes benefit from wind-flushing and retractable enclosures. These telescopes require enclosures with diameters of 30 m until roughly 100 m, the largest sizes for the ELTs (Extreme Large Telescopes), which will be built in the near future. We discuss developments and required technology for the realization of these large sizes.

  6. An emergency response mobile robot for operations in combustible atmospheres

    NASA Technical Reports Server (NTRS)

    Stone, Henry W. (Inventor); Ohm, Timothy R. (Inventor)

    1993-01-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  7. Emergency response mobile robot for operations in combustible atmospheres

    NASA Technical Reports Server (NTRS)

    Stone, Henry W. (Inventor); Ohm, Timothy R. (Inventor)

    1995-01-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  8. Sound absorption of microperforated panels inside compact acoustic enclosures

    NASA Astrophysics Data System (ADS)

    Yang, Cheng; Cheng, Li

    2016-01-01

    This paper investigates the sound absorption effect of microperforated panels (MPPs) in small-scale enclosures, an effort stemming from the recent interests in using MPPs for noise control in compact mechanical systems. Two typical MPP backing cavity configurations (an empty backing cavity and a honeycomb backing structure) are studied. Although both configurations provide basically the same sound absorption curves from standard impedance tube measurements, their in situ sound absorption properties, when placed inside a small enclosure, are drastically different. This phenomenon is explained using a simple system model based on modal analyses. It is shown that the accurate prediction of the in situ sound absorption of the MPPs inside compact acoustic enclosures requires meticulous consideration of the configuration of the backing cavity and its coupling with the enclosure in front. The MPP structure should be treated as part of the entire system, rather than an absorption boundary characterized by the surface impedance, calculated or measured in simple acoustic environment. Considering the spatial matching between the acoustic fields across the MPP, the possibility of attenuating particular enclosure resonances by partially covering the enclosure wall with a properly designed MPP structure is also demonstrated.

  9. An emergency response mobile robot for operations in combustible atmospheres

    NASA Astrophysics Data System (ADS)

    Stone, Henry W.; Ohm, Timothy R.

    1993-11-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  10. Emergency response mobile robot for operations in combustible atmospheres

    NASA Astrophysics Data System (ADS)

    Stone, Henry W.; Ohm, Timothy R.

    1995-08-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  11. PROCEDURE FOR ESTIMATING PERMANENT TOTAL ENCLOSURE COSTS

    EPA Science Inventory

    The paper discusses a procedure for estimating permanent total enclosure (PTE) costs. (NOTE: Industries that use add-on control devices must adequately capture emissions before delivering them to the control device. One way to capture emissions is to use PTEs, enclosures that mee...

  12. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  13. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  14. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  15. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  16. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  17. Tissue stimulator enclosure welding fixture

    NASA Technical Reports Server (NTRS)

    Mcclure, S. R.

    1977-01-01

    It was demonstrated that the thickness of the stimulator titanium enclosure is directly related to the battery recharge time cycle. Reduction of the titanium enclosure thickness from approximately 0.37 mm (0.015 inch) to 0.05 mm (0.002 inch) significantly reduced the recharge time cycle and thereby patient inconvenience. However, fabrication of titanium enclosures from the thinner material introduced problems in forming, holding, and welding that required improvement in state of the art shop practices. The procedures that were utilized to resolve these fabrication problems are described.

  18. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... accordance with § 35.1340. If encapsulation or enclosure is used as a method of abatement, ongoing lead-based...

  19. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... accordance with § 35.1340. If encapsulation or enclosure is used as a method of abatement, ongoing lead-based...

  20. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... accordance with § 35.1340. If encapsulation or enclosure is used as a method of abatement, ongoing lead-based...

  1. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... accordance with § 35.1340. If encapsulation or enclosure is used as a method of abatement, ongoing lead-based...

  2. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... accordance with § 35.1340. If encapsulation or enclosure is used as a method of abatement, ongoing lead-based...

  3. Low temperature sodium-beta battery

    DOEpatents

    Farmer, Joseph C

    2013-11-19

    A battery that will operate at ambient temperature or lower includes an enclosure, a current collector within the enclosure, an anode that will operate at ambient temperature or lower within the enclosure, a cathode that will operate at ambient temperature or lower within the enclosure, and a separator and electrolyte within the enclosure between the anode and the cathode. The anode is a sodium eutectic anode that will operate at ambient temperature or lower and is made of a material that is in a liquid state at ambient temperature or lower. The cathode is a low melting ion liquid cathode that will operate at ambient temperature or lower and is made of a material that is in a liquid state at ambient temperature or lower.

  4. Welding methods for joining thermoplastic polymers for the hermetic enclosure of medical devices.

    PubMed

    Amanat, Negin; James, Natalie L; McKenzie, David R

    2010-09-01

    New high performance polymers have been developed that challenge traditional encapsulation materials for permanent active medical implants. The gold standard for hermetic encapsulation for implants is a titanium enclosure which is sealed using laser welding. Polymers may be an alternative encapsulation material. Although many polymers are biocompatible, and permeability of polymers may be reduced to acceptable levels, the ability to create a hermetic join with an extended life remains the barrier to widespread acceptance of polymers for this application. This article provides an overview of the current techniques used for direct bonding of polymers, with a focus on thermoplastics. Thermal bonding methods are feasible, but some take too long and/or require two stage processing. Some methods are not suitable because of excessive heat load which may be delivered to sensitive components within the capsule. Laser welding is presented as the method of choice; however the establishment of suitable laser process parameters will require significant research. 2010. Published by Elsevier Ltd.

  5. Fluid flow and heat transfer characteristics of an enclosure with fin as a top cover of a solar collector

    NASA Astrophysics Data System (ADS)

    Ambarita, H.; Ronowikarto, A. D.; Siregar, R. E. T.; Setyawan, E. Y.

    2018-03-01

    To reduce heat loses in a flat plate solar collector, double glasses cover is employed. Several studies show that the heat loss from the glass cover is still very significant in comparison with other losses. Here, double glasses cover with attached fins is proposed. In the present work, the fluid flow and heat transfer characteristics of the enclosure between the double glass cover are investigated numerically. The objective is to examine the effect of the fin to the heat transfer rate of the cover. Two-dimensional governing equations are developed. The governing equations and the boundary conditions are solved using commercial Computational Fluid Dynamics code. The fluid flow and heat transfer characteristics are plotted, and numerical results are compared with empirical correlation. The results show that the presence of the fin strongly affects the fluid flow and heat transfer characteristics. The fin can reduce the heat transfer rate up to 22.42% in comparison with double glasses cover without fins.

  6. 46 CFR 108.455 - Enclosure openings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Enclosure openings. 108.455 Section 108.455 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.455 Enclosure...

  7. 46 CFR 108.455 - Enclosure openings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Enclosure openings. 108.455 Section 108.455 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.455 Enclosure...

  8. EFFECTS OF 4-NONYLPHENOL ON BENTHIC MACROINVERTEBRATES AND INSECT EMERGENCE IN LITTORAL ENCLOSURES

    EPA Science Inventory

    The effect of 4-nonylphenol (NP) on benthic, freshwater marcroinvertebrates in littoral enclosures was evaluated over a two-year period. Enclosures received 11 NP applications, 48 h apart, with nominal ratres of 3,30, 100, and 300 ?g/L.

  9. The 3.5-Meter Telescope Enclosure

    DTIC Science & Technology

    1994-04-01

    and acoustic vibrations, and the enclosure cannot be stopped quickly in an emergency. Also, the work of Zago indicates that open-air operation of the...enclosure. This capability is useful during operational testing and maintenance of the telescope. ’ Zago , L., "Design and Performance of Large

  10. High performance internal reforming unit for high temperature fuel cells

    DOEpatents

    Ma, Zhiwen [Sandy Hook, CT; Venkataraman, Ramakrishnan [New Milford, CT; Novacco, Lawrence J [Brookfield, CT

    2008-10-07

    A fuel reformer having an enclosure with first and second opposing surfaces, a sidewall connecting the first and second opposing surfaces and an inlet port and an outlet port in the sidewall. A plate assembly supporting a catalyst and baffles are also disposed in the enclosure. A main baffle extends into the enclosure from a point of the sidewall between the inlet and outlet ports. The main baffle cooperates with the enclosure and the plate assembly to establish a path for the flow of fuel gas through the reformer from the inlet port to the outlet port. At least a first directing baffle extends in the enclosure from one of the sidewall and the main baffle and cooperates with the plate assembly and the enclosure to alter the gas flow path. Desired graded catalyst loading pattern has been defined for optimized thermal management for the internal reforming high temperature fuel cells so as to achieve high cell performance.

  11. Calculation of three-dimensional (3-D) internal flow by means of the velocity-vorticity formulation on a staggered grid

    NASA Technical Reports Server (NTRS)

    Stremel, Paul M.

    1995-01-01

    A method has been developed to accurately compute the viscous flow in three-dimensional (3-D) enclosures. This method is the 3-D extension of a two-dimensional (2-D) method developed for the calculation of flow over airfoils. The 2-D method has been tested extensively and has been shown to accurately reproduce experimental results. As in the 2-D method, the 3-D method provides for the non-iterative solution of the incompressible Navier-Stokes equations by means of a fully coupled implicit technique. The solution is calculated on a body fitted computational mesh incorporating a staggered grid methodology. In the staggered grid method, the three components of vorticity are defined at the centers of the computational cell sides, while the velocity components are defined as normal vectors at the centers of the computational cell faces. The staggered grid orientation provides for the accurate definition of the vorticity components at the vorticity locations, the divergence of vorticity at the mesh cell nodes and the conservation of mass at the mesh cell centers. The solution is obtained by utilizing a fractional step solution technique in the three coordinate directions. The boundary conditions for the vorticity and velocity are calculated implicitly as part of the solution. The method provides for the non-iterative solution of the flow field and satisfies the conservation of mass and divergence of vorticity to machine zero at each time step. To test the method, the calculation of simple driven cavity flows have been computed. The driven cavity flow is defined as the flow in an enclosure driven by a moving upper plate at the top of the enclosure. To demonstrate the ability of the method to predict the flow in arbitrary cavities, results will he shown for both cubic and curved cavities.

  12. Ratios of colony mass to thermal conductance of tree and man-made nest enclosures of Apis mellifera: implications for survival, clustering, humidity regulation and Varroa destructor

    NASA Astrophysics Data System (ADS)

    Mitchell, Derek

    2016-05-01

    In the absence of human intervention, the honeybee ( Apis mellifera L.) usually constructs its nest in a tree within a tall, narrow, thick-walled cavity high above the ground (the enclosure); however, most research and apiculture is conducted in the thin-walled, squat wooden enclosures we know as hives. This experimental research, using various hives and thermal models of trees, has found that the heat transfer rate is approximately four to seven times greater in the hives in common use, compared to a typical tree enclosure in winter configuration. This gives a ratio of colony mass to lumped enclosure thermal conductance (MCR) of less than 0.8 kgW-1 K for wooden hives and greater than 5 kgW-1 K for tree enclosures. This result for tree enclosures implies higher levels of humidity in the nest, increased survival of smaller colonies and lower Varroa destructor breeding success. Many honeybee behaviours previously thought to be intrinsic may only be a coping mechanism for human intervention; for example, at an MCR of above 2 kgW-1 K, clustering in a tree enclosure may be an optional, rare, heat conservation behaviour for established colonies, rather than the compulsory, frequent, life-saving behaviour that is in the hives in common use. The implied improved survival in hives with thermal properties of tree nests may help to solve some of the problems honeybees are currently facing in apiculture.

  13. 30 CFR 57.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Electricity Surface and Underground § 57.12025 Grounding circuit enclosures. All metal enclosing or encasing electrical circuits shall be grounded or provided with equivalent protection. This requirement does not apply... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding circuit enclosures. 57.12025 Section...

  14. 9 CFR 3.56 - Sanitation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits.... Measures shall be taken to prevent the wetting of rabbits in such enclosures if a washing process is used... primary enclosures. (1) Primary enclosures for rabbits shall be sanitized at least once every 30 days in...

  15. 9 CFR 3.28 - Primary enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... constructed of smooth material substantially impervious to liquids and moisture. (2) Primary enclosures shall... shall be so constructed as to allow feces to pass through the spaces of the mesh or wire: Provided...) Space requirements for primary enclosures acquired before August 15, 1990—(1) Guinea pigs and hamsters...

  16. 9 CFR 3.28 - Primary enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... constructed of smooth material substantially impervious to liquids and moisture. (2) Primary enclosures shall... shall be so constructed as to allow feces to pass through the spaces of the mesh or wire: Provided...) Space requirements for primary enclosures acquired before August 15, 1990—(1) Guinea pigs and hamsters...

  17. 9 CFR 3.31 - Sanitation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... foods, or moisture condensation, the guinea pigs or hamsters shall be transferred to clean primary enclosures. (3) Prior to the introduction of guinea pigs or hamsters into empty primary enclosures previously...) Primary enclosures for guinea pigs or hamsters shall be sanitized by washing them with hot water (180 °F...

  18. 50 CFR 14.131 - Primary enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... same primary enclosure with an adult marine mammal other than its mother. Socially dependent animals (e... 50 Wildlife and Fisheries 1 2013-10-01 2013-10-01 false Primary enclosures. 14.131 Section 14.131 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING...

  19. 50 CFR 14.131 - Primary enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... same primary enclosure with an adult marine mammal other than its mother. Socially dependent animals (e... 50 Wildlife and Fisheries 1 2012-10-01 2012-10-01 false Primary enclosures. 14.131 Section 14.131 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING...

  20. Method for enhancing the resolving power of ion mobility separations over a limited mobility range

    DOEpatents

    Shvartsburg, Alexandre A; Tang, Keqi; Smith, Richard D

    2014-09-23

    A method for raising the resolving power, specificity, and peak capacity of conventional ion mobility spectrometry is disclosed. Ions are separated in a dynamic electric field comprising an oscillatory field wave and opposing static field, or at least two counter propagating waves with different parameters (amplitude, profile, frequency, or speed). As the functional dependencies of mean drift velocity on the ion mobility in a wave and static field or in unequal waves differ, only single species is equilibrated while others drift in either direction and are mobility-separated. An ion mobility spectrum over a limited range is then acquired by measuring ion drift times through a fixed distance inside the gas-filled enclosure. The resolving power in the vicinity of equilibrium mobility substantially exceeds that for known traveling-wave or drift-tube IMS separations, with spectra over wider ranges obtainable by stitching multiple segments. The approach also enables low-cutoff, high-cutoff, and bandpass ion mobility filters.

  1. Nonlinear Dynamics of a Diffusing Interface

    NASA Technical Reports Server (NTRS)

    Duval, Walter M. B.

    2001-01-01

    Excitation of two miscible-viscous liquids inside a bounded enclosure in a microgravity environment has shown the evolution of quasi-stationary waves of various modes for a range of parameters. We examine computationally the nonlinear dynamics of the system as the interface breakup and bifurcates to resonance structures typified by the Rayleigh-Taylor instability mechanism. Results show that when the mean steady field is much smaller than the amplitude of the sinusoidal excitation, the system behaves linearly, and growth of quasi-stationary waves occurs through the Kelvin-Helmholtz instability mechanism. However, as the amplitude of excitation increases, nonlinearity occurs through subharmonic bifurcation prior to broadband chaos.

  2. 30 CFR 75.701 - Grounding metallic frames, casings, and other enclosures of electric equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding metallic frames, casings, and other... Grounding § 75.701 Grounding metallic frames, casings, and other enclosures of electric equipment. [Statutory Provisions] Metallic frames, casings, and other enclosures of electric equipment that can become...

  3. 9 CFR 3.6 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment, and Transportation of Dogs and Cats 1 Facilities and Operating Standards § 3.6 Primary enclosures. Primary enclosures for dogs and... they: (i) Have no sharp points or edges that could injure the dogs and cats; (ii) Protect the dogs and...

  4. 46 CFR 169.677 - Equipment protection and enclosure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Vessels of Less Than 100 Gross Tons § 169.677 Equipment protection and enclosure. (a) Except as provided... 46 Shipping 7 2010-10-01 2010-10-01 false Equipment protection and enclosure. 169.677 Section 169.677 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL...

  5. 50 CFR 14.172 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Wild Mammals and Birds to the United States Specifications for Birds § 14.172 Primary enclosures. (a) A primary enclosure for birds shall have ventilation openings on two vertical sides that comprise at least... creating a draft. (b) Perches shall be provided for birds that rest by perching. The diameter of the perch...

  6. 46 CFR 111.70-5 - Heater circuits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-5 Heater circuits. (a) If an enclosure for a motor, master switch, or other equipment has an electric heater inside the enclosure that is energized.... (b) If the location of the enclosure for a motor, master switch, or other equipment for deck...

  7. 9 CFR 3.6 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment, and Transportation of Dogs and Cats 1 Facilities and Operating Standards § 3.6 Primary enclosures. Primary enclosures for dogs and... they: (i) Have no sharp points or edges that could injure the dogs and cats; (ii) Protect the dogs and...

  8. Uncertainty analysis of diffuse-gray radiation enclosure problems: A hypersensitive case study

    NASA Technical Reports Server (NTRS)

    Taylor, Robert P.; Luck, Rogelio; Hodge, B. K.; Steele, W. Glenn

    1993-01-01

    An uncertainty analysis of diffuse-gray enclosure problems is presented. The genesis was a diffuse-gray enclosure problem which proved to be hypersensitive to the specification of view factors. This genesis is discussed in some detail. The uncertainty analysis is presented for the general diffuse-gray enclosure problem and applied to the hypersensitive case study. It was found that the hypersensitivity could be greatly reduced by enforcing both closure and reciprocity for the view factors. The effects of uncertainties in the surface emissivities and temperatures are also investigated.

  9. Recombination device for storage batteries

    DOEpatents

    Kraft, H.; Ledjeff, K.

    1984-01-01

    A recombination device including a gas-tight enclosure connected to receive the discharge gases from a rechargeable storage battery. Catalytic material for the recombination of hydrogen and oxygen to form water is supported within the enclosure. The enclosure is sealed from the atmosphere by a liquid seal including two vertical chambers interconnected with an inverted U-shaped overflow tube. The first chamber is connected at its upper portion to the enclosure and the second chamber communicates at its upper portion with the atmosphere. If the pressure within the enclosure differs as overpressure or vacuum by more than the liquid level, the liquid is forced into one of the two chambers and the overpressure is vented or the vacuum is relieved. The recombination device also includes means for returning recombined liquid to the battery and for absorbing metal hydrides.

  10. Recombination device for storage batteries

    DOEpatents

    Kraft, Helmut; Ledjeff, Konstantin

    1985-01-01

    A recombination device including a gas-tight enclosure connected to receive he discharge gases from a rechargeable storage battery. Catalytic material for the recombination of hydrogen and oxygen to form water is supported within the enclosure. The enclosure is sealed from the atmosphere by a liquid seal including two vertical chambers interconnected with an inverted U-shaped overflow tube. The first chamber is connected at its upper portion to the enclosure and the second chamber communicates at its upper portion with the atmosphere. If the pressure within the enclosure differs as overpressure or vacuum by more than the liquid level, the liquid is forced into one of the two chambers and the overpressure is vented or the vacuum is relieved. The recombination device also includes means for returning recombined liquid to the battery and for absorbing metal hydrides.

  11. VIRUS instrument enclosures

    NASA Astrophysics Data System (ADS)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  12. Enclosure design for flock-level, chronic exposure of birds to air contaminant mixtures.

    PubMed

    North, Michelle A; Kinniburgh, David W; Smits, Judit E G

    2018-05-01

    The objective of this study was to design an enclosure suitable for studying the ecotoxicological effects of vehicle emissions on groups of wild birds without compromising welfare. Two, adjacent enclosures sheltered from sunlight, wind and rain, were bird-proofed and wrapped with thick polyethylene sheeting. Emissions were directed into the treatment enclosure from the exhaust of a light-duty gasoline truck, using flexible, heat-proof pipe, with joins sealed to prevent leakage. During active exposure, the engine was idled for 5 h/day, 6 days/week for 4 weeks. Fans maintained positive pressure (controls) and negative pressure (treatment), preventing cross-contamination of enclosures and protecting investigators. Four sets of passive, badge-type samplers were distributed across each enclosure, measuring nitrogen dioxide, sulfur dioxide and volatile organic compounds (NO 2 , SO 2 and VOCs, respectively), and were complemented by active monitors measuring VOCs and particulate matter (2.5 µm diameter, PM 2.5 ). We found that the concentrations of NO 2 , SO 2 and PM 2.5 were not different between treatment and control enclosures. Volatile organic compounds (e.g. benzene, toluene, ethylbenzene and xylenes) were approximately six times higher in the treatment enclosure than control (13.23 and 2.13 µg m -1 , respectively). In conclusion, this represents a successful, practical design for studying the effects of sub-chronic to chronic exposure to realistic mixtures of vehicle exhaust contaminants, in groups of birds. Recommended modifications for future research include a chassis dynamometer (vehicle treadmill), to better replicate driving conditions including acceleration and deceleration.

  13. Effects of a new molt-inducing insecticide, tebufenozide, on zooplankton communities in lake enclosures.

    PubMed

    Kreutzweiser, D P; Thomas, D R

    1995-10-01

    : A potent ecdysone agonist, tebufenozide, has recently been developed as a molt-inducing insecticide to control defoliating lepidopterans. As part of continuing research efforts to assess the effectiveness and environmental safety of this material for insect pest management in Canadian forests, tebufenozide (RH-5992-2F) was applied to large lake enclosures and the effects on zooplankton communities were evaluated. There were significant treatment effects at all test concentrations (0.07-0.66 mg L(-1) tebufenozide). Concentration-dependent reductions in the abundance of cladocerans indicated that there were direct toxic effects of tebufenozide on this group of macrozooplankton. There were no indications of direct toxic effects on copepods. Significant increases in abundance of rotifers in treated enclosures at the three higher test concentrations were coincident with reductions in cladocerans and indicated secondary effects of the insecticide on the abundance of microzooplankton. There were no significant differences among treated and control enclosures in chlorophyll a concentrations, indicating that tebufenozide did not have direct effects on phytoplankton biomass, nor did the alterations in the zooplankton communities of treated enclosures have measurable secondary effects on phytoplankton biomass. Daytime dissolved oxygen concentrations were significantly higher in treated enclosures than in controls, indicating that the perturbation to biotic communities of some treated enclosures was sufficient to induce measurable changes in system-level functional attributes. Recovery of zooplankton communities in the enclosures occurred within 1-2 months at 0.07 and 0.13 mg l(-1) and by the following summer (12-13 months) at 0.33 and 0.66 mg l(-1).

  14. MROI Array telescopes: the relocatable enclosure domes

    NASA Astrophysics Data System (ADS)

    Marchiori, G.; Busatta, A.; Payne, I.

    2016-07-01

    The MROI - Magdalena Ridge Interferometer is a project which comprises an array of up to 10 1.4m diameter mirror telescopes arranged in a "Y" configuration. Each of these telescopes will be housed inside a Unit Telescope Enclosure (UTE) which are relocatable onto any of 28 stations. EIE GROUP Srl, Venice - Italy, was awarded the contract for the design, the construction and the erection on site of the MROI by the New Mexico Institute of Mining and Technology. The close-pack array of the MROI - including all 10 telescopes, several of which are at a relative distance of less than 8m center to center from each other - necessitated an original design for the Unit Telescope Enclosure (UTE). This innovative design enclosure incorporates a unique dome/observing aperture system to be able to operate in the harsh environmental conditions encountered at an altitude of 10,460ft (3,188m). The main characteristics of this Relocatable Enclosure Dome are: a Light insulated Steel Structure with a dome made of composites materials (e.g. glass/carbon fibers, sandwich panels etc.), an aperture motorized system for observation, a series of louvers for ventilation, a series of electrical and plants installations and relevant auxiliary equipment. The first Enclosure Dome is now under construction and the completion of the mounting on site id envisaged by the end of 2016. The relocation system utilizes a modified reachstacker (a transporter used to handle freight containers) capable of maneuvering between and around the enclosures, capable of lifting the combined weight of the enclosure with the telescope (30tons), with minimal impacts due to vibrations.

  15. 50 CFR 14.106 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... affixed in the conveyance or has an open top for certain large mammals, spacer bars allowing circulation... enclosure, a sling, or on foam is exempt from the requirement to contain litter. An enclosure used to... height, “Live Animals” or “Wild Animals”, “Do Not Tip,” “Only Authorized Personnel May Open Container...

  16. 50 CFR 14.106 - Primary enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... affixed in the conveyance or has an open top for certain large mammals, spacer bars allowing circulation... enclosure, a sling, or on foam is exempt from the requirement to contain litter. An enclosure used to... height, “Live Animals” or “Wild Animals”, “Do Not Tip,” “Only Authorized Personnel May Open Container...

  17. 50 CFR 14.106 - Primary enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... affixed in the conveyance or has an open top for certain large mammals, spacer bars allowing circulation... enclosure, a sling, or on foam is exempt from the requirement to contain litter. An enclosure used to... height, “Live Animals” or “Wild Animals”, “Do Not Tip,” “Only Authorized Personnel May Open Container...

  18. 50 CFR 14.106 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... affixed in the conveyance or has an open top for certain large mammals, spacer bars allowing circulation... enclosure, a sling, or on foam is exempt from the requirement to contain litter. An enclosure used to... height, “Live Animals” or “Wild Animals”, “Do Not Tip,” “Only Authorized Personnel May Open Container...

  19. 50 CFR 14.106 - Primary enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... affixed in the conveyance or has an open top for certain large mammals, spacer bars allowing circulation... enclosure, a sling, or on foam is exempt from the requirement to contain litter. An enclosure used to... height, “Live Animals” or “Wild Animals”, “Do Not Tip,” “Only Authorized Personnel May Open Container...

  20. 40 CFR 63.450 - Standards for enclosures and closed-vent systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...

  1. 40 CFR 63.450 - Standards for enclosures and closed-vent systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...

  2. 40 CFR 63.450 - Standards for enclosures and closed-vent systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...

  3. 40 CFR 63.450 - Standards for enclosures and closed-vent systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...

  4. 40 CFR 63.450 - Standards for enclosures and closed-vent systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-vent systems. 63.450 Section 63.450 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Standards for enclosures and closed-vent systems. (a) Each enclosure and closed-vent system specified in..., or repairs. (c) Each component of the closed-vent system used to comply with §§ 63.443(c), 63.444(b...

  5. Filtering apparatus

    DOEpatents

    Haldipur, G.B.; Dilmore, W.J.

    1992-09-01

    A vertical vessel is described having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas. 18 figs.

  6. Filtering apparatus

    DOEpatents

    Haldipur, Gaurang B.; Dilmore, William J.

    1992-01-01

    A vertical vessel having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas.

  7. Radioactive waste material melter apparatus

    DOEpatents

    Newman, D.F.; Ross, W.A.

    1990-04-24

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs.

  8. Animal biocalorimeter and waste management system

    NASA Technical Reports Server (NTRS)

    Poppendiek, Heinz F. (Inventor); Trimailo, William R. (Inventor)

    1995-01-01

    A biocalorimeter and waste management system is provided for making metabolic heat release measurements of animals or humans in a calorimeter (enclosure) using ambient air as a low velocity source of ventilating air through the enclosure. A shroud forces ventilating air to pass over the enclosure from an end open to ambient air at the end of the enclosure opposite its ventilating air inlet end and closed around the inlet end of the enclosure in order to obviate the need for regulating ambient air temperature. Psychrometers for measuring dry- and wet-bulb temperature of ventilating air make it possible to account for the sensible and latent heat additions to the ventilating air. A waste removal system momentarily recirculates high velocity air in a closed circuit through the calorimeter wherein a sudden rise in moisture is detected in the ventilating air from the outlet.

  9. Radioactive waste material melter apparatus

    DOEpatents

    Newman, Darrell F.; Ross, Wayne A.

    1990-01-01

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another.

  10. Laying hen movement in a commercial aviary: Enclosure to floor and back again.

    PubMed

    Campbell, D L M; Makagon, M M; Swanson, J C; Siegford, J M

    2016-01-01

    Many producers in the laying hen industry, including in North America, are phasing out conventional cages in response to consumer demands and sometimes subsequent legislation. Alternative housing systems such as aviaries are being implemented in an attempt to improve hen welfare. Aviaries provide additional space and resources to groups of hens, including a litter area on the floor. However, little is known about hen movement between tiered enclosures and floor litter areas in aviary systems. Diurnal rhythms and social attraction may result in peak times of movement that could lead to overcrowding of areas, or alternatively hen preferences may lead to some areas not being fully utilized. We monitored hen movement between tiered enclosures and litter areas, including movement on and off the outer perch, across the day at peak, mid and end of lay in a commercial aviary. Hens moved onto and off of the open litter area across the day, transitioning between tiered enclosures, outer perches, open litter areas, and litter areas under tiered enclosures. At certain times of day, there were periods of greater hen movement down to the open litter area and between litter areas. For example, more hens were typically observed exiting enclosures, jumping from perches to open litter, and traveling between open litter and litter under tiered enclosures in the morning (all P ≤ 0.001). In all but one instance, more hens were observed on open litter areas in the afternoon than at other times of day (all P ≤ 0.029). However, hen re-entry to tiered enclosures showed less circadian patterning. Hen movement was observed between areas of interest at all sampled time periods, indicating hens use all areas of the system. Further research should examine whether all individual hens do move between areas equally, including within levels of the tiered enclosure, or if crowding occurs on the outer perches or in the litter during times of peak movement. © 2015 Poultry Science Association Inc.

  11. Characterization of Bed Morphodynamics Using Multibeam Echo Sounding (MBES) and Wavelet Transform (WT) Analysis

    DTIC Science & Technology

    2013-09-30

    a dynamical model for an acoustic enclosure using the wavelet Transform”. Applied Acoustics, 68 (4), 473-490. Liu, P.C. (1994). “Wavelet spectrum...Chapter 2 in ASCE Manual of Practice 110, Sedimentation Engineering: Processes, Measurements, Modelling and Practice. Edited by M. H. García, ASCE...Present Ripple Predictors”. 28th International Conference on Ocean, Offshore and Arctic Engineering. Mier, J.M., and Garcia, M.H. (2011). “ Erosion

  12. Aerodynamic and Acoustic Tests of a 1/15 Scale Model Dry Cooled Jet Aircraft Runup Noise Suppression System,

    DTIC Science & Technology

    1975-10-01

    sophisticated wet-cooled systems having scrubbers and their associated water treatment facilities . The United States Navy has recognized these Hush... venturi meter air inlet to measure the pumped air flow and the exhaust enclosure is provided with suitable ports for the flow to exit. The test program...constantan thermo- couple and venturi flow meters were used to measure the aerodynamic/thermo- dynamic information required from the tests (pressure

  13. Integrative monitoring of water storage variations at the landscape-scale with an iGrav superconducting gravimeter in a field enclosure

    NASA Astrophysics Data System (ADS)

    Guntner, A.; Reich, M.; Mikolaj, M.; Creutzfeldt, B.; Schroeder, S.; Wziontek, H.

    2017-12-01

    In spite of the fundamental role of the landscape water balance for the Earth's water and energy cycles, monitoring the water balance and related storage dynamics beyond the point scale is notoriously difficult due to the multitude of flow and storage processes and their spatial heterogeneity. We present the first outdoor deployment of an iGrav superconducting gravimeter (SG) in a minimized field enclosure on a wet-temperate grassland site for integrative monitoring of water storage changes. It is shown that the system performs similarly precise as SGs that have hitherto been deployed in observatory buildings, but with higher sensitivity to hydrological variations in the surroundings of the instrument. Gravity variations observed by the field setup are almost independent of the depth below the terrain surface where water storage changes occur, and thus the field SG system directly observes the total water storage change in an integrative way. We provide a framework to single out the water balance components actual evapotranspiration and lateral subsurface discharge from the gravity time series on annual to daily time scales. With about 99% and 85% of the gravity signal originating within a radius of 4000 and 200 meter around the instrument, respectively, the setup paves the road towards gravimetry as a continuous hydrological field monitoring technique for water storage dynamics at the landscape scale.

  14. Evaluating Conservation Breeding Success for an Extinct-in-the-Wild Antelope.

    PubMed

    Little, Holly A; Gilbert, Tania C; Athorn, Marie L; Marshall, Andrew R

    2016-01-01

    With the number of threatened species increasing globally, conservation breeding is vitally important now more than ever. However, no previous peer-reviewed study has attempted to determine how the varying conditions across zoos have influenced breeding by an extinct-in-the-wild species. We therefore use questionnaires and studbook data to evaluate the influence of husbandry practices and enclosure design on scimitar-horned oryx (Oryx dammah) breeding success, at the herd level. Regression models were used to identify the variables that best predicted breeding success among 29 zoos across a five-year period. Calf survival decreased with herd age and the use of soft substrates in hardstand areas (yard area usually adjacent to the indoor housing), explaining 30.7% of overall variation. Calf survival also decreased where herds were small and where food provisions were not raised (and hence likely incited competition), although these were less influential. Likewise, birth rate decreased with soft substrates in hardstand areas and unraised food provisions, although these were less influential than for calf survival. Birth rate increased with year-round male presence, yet this decreased calf survival. Compared to previous studies, the number of enclosure/husbandry influences on breeding were relatively few. Nevertheless, these few enclosure/husbandry influences explained over one third of the variation in calf survival. Our data therefore suggest some potential improvements and hence that extinct-in-the-wild species stand a greater chance of survival with empirical design of zoo enclosures and husbandry methods.

  15. An automated growth enclosure for metabolic labeling of Arabidopsis thaliana with 13C-carbon dioxide - an in vivo labeling system for proteomics and metabolomics research

    PubMed Central

    2011-01-01

    Background Labeling whole Arabidopsis (Arabidopsis thaliana) plants to high enrichment with 13C for proteomics and metabolomics applications would facilitate experimental approaches not possible by conventional methods. Such a system would use the plant's native capacity for carbon fixation to ubiquitously incorporate 13C from 13CO2 gas. Because of the high cost of 13CO2 it is critical that the design conserve the labeled gas. Results A fully enclosed automated plant growth enclosure has been designed and assembled where the system simultaneously monitors humidity, temperature, pressure and 13CO2 concentration with continuous adjustment of humidity, pressure and 13CO2 levels controlled by a computer running LabView software. The enclosure is mounted on a movable cart for mobility among growth environments. Arabidopsis was grown in the enclosure for up to 8 weeks and obtained on average >95 atom% enrichment for small metabolites, such as amino acids and >91 atom% for large metabolites, including proteins and peptides. Conclusion The capability of this labeling system for isotope dilution experiments was demonstrated by evaluation of amino acid turnover using GC-MS as well as protein turnover using LC-MS/MS. Because this 'open source' Arabidopsis 13C-labeling growth environment was built using readily available materials and software, it can be adapted easily to accommodate many different experimental designs. PMID:21310072

  16. Investigation of Thermal Stress Convection in Nonisothermal Gases under Microgravity Conditions

    NASA Technical Reports Server (NTRS)

    Mackowski, Daniel W.

    1999-01-01

    The project has sought to ascertain the veracity of the Burnett relations, as applied to slow moving, highly nonisothermal gases, by comparison of convection and stress predictions with those generated by the DSMC method. The Burnett equations were found to provide reasonable descriptions of the pressure distribution and normal stress in stationary gases with a 1-D temperature gradient. Continuum/Burnett predictions of thermal stress convection in 2-D heated enclosures, however, are not quantitatively supported by DSMC results. For such situations, it appears that thermal creep flows, generated at the boundaries of the enclosure, will be significantly larger than the flows resulting from thermal stress in the gas.

  17. Development and Verification of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

    NASA Technical Reports Server (NTRS)

    Salazar, Giovanni; Droba, Justin C.; Oliver, Brandon; Amar, Adam J.

    2016-01-01

    With the recent development of multi-dimensional thermal protection system (TPS) material response codes, the capability to account for surface-to-surface radiation exchange in complex geometries is critical. This paper presents recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute geometric view factors for radiation problems involving multiple surfaces. Verification of the code's radiation capabilities and results of a code-to-code comparison are presented. Finally, a demonstration case of a two-dimensional ablating cavity with enclosure radiation accounting for a changing geometry is shown.

  18. Conjugate Heat Transfer in Rayleigh-Bénard Convection in a Square Enclosure

    PubMed Central

    Hashim, Ishak

    2014-01-01

    Conjugate natural convection-conduction heat transfer in a square enclosure with a finite wall thickness is studied numerically in the present paper. The governing parameters considered are the Rayleigh number (5 × 103 ≤ Ra ≤ 106), the wall-to-fluid thermal conductivity ratio (0.5 ≤ Kr ≤ 10), and the ratio of wall thickness to its height (0.2 ≤ D ≤ 0.4). The staggered grid arrangement together with MAC method was employed to solve the governing equations. It is found that the fluid flow and the heat transfer can be controlled by the thickness of the bottom wall, the thermal conductivity ratio, and the Rayleigh number. PMID:24971390

  19. Spacing behaviour of juvenile corn mice, Calomys musculinus , at the beginning of the breeding period, in absence of adult males

    NASA Astrophysics Data System (ADS)

    Steinmann, Andrea; Priotto, José; Sommaro, Lucia; Polop, Jaime

    2006-05-01

    This research was carried out to examine the hypothesis that the absence of fathers promotes a different spacing behaviour in juveniles Calomys musculinus at the beginning of the breeding period. The study was carried out in four 0.25-ha enclosures (two control and two experimental), in a natural pasture, between November 2003 and February 2004. In this study the fathers were removed from the experimental enclosures after juveniles were born. Home-range size depended on sex of juveniles and treatment (father removal). In control and experimental enclosures, female home-range sizes were always smaller than male home-ranges. Male home-ranges were always larger in experimental enclosures than in control enclosures. Treatment and overlap type (intra- and inter-sexual) were not independent. The overlap proportions of male home-ranges were greatest in experimental enclosures than in control enclosures, in both the overlap types (male/male, males/females). The intra- (females/females) and inter-sexual (females/males) overlap proportions of female home-ranges were independent of treatment. In C. musculinus, at the beginning of the breeding period and in absence of adult males, juvenile males increase their home-range size and therefore the degree of inter- and intra-sexual home-range overlap as a mechanism for enlarging the number of receptive females that they encounter.

  20. Assessing enclosure design and husbandry practices for successful keeping and breeding of the Burmese brow antlered deer (Eld's deer, Rucervus eldii thamin) in European zoos.

    PubMed

    Wall, Ellis L; Hartley, Matt

    2017-05-01

    The endangered Burmese brow antlered deer (Rucervus eldii thamin) is a medium sized tropical cervid kept in a number of European zoos. Studbook data and anecdotal reports have suggested that this species suffers from poor reproductive success and relatively high neonatal mortality in captivity. Questionnaires were sent to 10 European zoos, holding 91 (20.71.0) deer, in order to record information on husbandry practices and enclosure design. Studbook analysis was performed to determine reproductive success and mortality values at each of the zoos participating in the study. Statistical analysis was carried out to identify any links between husbandry or enclosure design and the population parameters calculated from the studbook. From the nine zoos that were analyzed in this study, no significant differences were found for population parameters between male and female deer. Neonatal mortality was negatively correlated to enclosure size (in males) and enclosure cover (in females). Positive correlations were found between enclosure cover, average temperature and group size with life expectancy, and negative correlations between enclosure visibility and visitor distance with female life expectancy. These results may be useful for informing husbandry guidelines, although further research into stress responses in captivity is recommended for this species to improve their welfare. © 2017 Wiley Periodicals, Inc.

  1. In-situ fault detection apparatus and method for an encased energy storing device

    DOEpatents

    Hagen, Ronald A.; Comte, Christophe; Knudson, Orlin B.; Rosenthal, Brian; Rouillard, Jean

    2000-01-01

    An apparatus and method for detecting a breach in an electrically insulating surface of an electrically conductive power system enclosure within which a number of series connected energy storing devices are disposed. The energy storing devices disposed in the enclosure are connected to a series power connection. A detector is coupled to the series connection and detects a change of state in a test signal derived from the series connected energy storing devices. The detector detects a breach in the insulating layer of the enclosure by detecting a state change in the test signal from a nominal state to a non-nominal state. A voltage detector detects a state change of the test signals from a nominal state, represented by a voltage of a selected end energy storing device, to a non-nominal state, represented by a voltage that substantially exceeds the voltage of the selected opposing end energy storing device. Alternatively, the detector may comprise a signal generator that produces the test signal as a time-varying or modulated test signal and injects the test signal into the series connection. The detector detects the state change of the time-varying or modulated test signal from a nominal state, represented by a signal substantially equivalent to the test signal, to a non-nominal state, representative by an absence of the test signal.

  2. Drill string enclosure

    DOEpatents

    Jorgensen, D.K.; Kuhns, D.J.; Wiersholm, O.; Miller, T.A.

    1993-03-02

    The drill string enclosure consists of six component parts, including; a top bracket, an upper acrylic cylinder, an acrylic drill casing guide, a lower acrylic cylinder, a bottom bracket, and three flexible ducts. The upper acrylic cylinder is optional based upon the drill string length. The drill string enclosure allows for an efficient drill and sight operation at a hazardous waste site.

  3. Drill string enclosure

    DOEpatents

    Jorgensen, Douglas K.; Kuhns, Douglass J.; Wiersholm, Otto; Miller, Timothy A.

    1993-01-01

    The drill string enclosure consists of six component parts, including; a top bracket, an upper acrylic cylinder, an acrylic drill casing guide, a lower acrylic cylinder, a bottom bracket, and three flexible ducts. The upper acrylic cylinder is optional based upon the drill string length. The drill string enclosure allows for an efficient drill and sight operation at a hazardous waste site.

  4. Enclosure Then and Now: Rural Schools and Communities in the Wake of Market-Driven Agriculture

    ERIC Educational Resources Information Center

    Theobald, Paul; Rochon, Ronald S.

    2006-01-01

    The following is an historically-based analysis of a new phenomenon affecting rural schools and communities: animal confinement operations. A contrast is made between "enclosure" as it unfolded in England a few centuries ago and the way animal concentration units constitute a second, "modern" form of enclosure today. In both…

  5. 40 CFR 86.117-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... this section. (v) r=FID response factor to methanol. (vi) PB=Barometric pressure, in. Hg. (kPa). (vii) T=Enclosure ambient temperature, R(K). (viii) i=Indicates initial reading. (ix) f=Indicates final reading. (x)(A) k=3.05. (B) For SI units, k=17.60. (xi) MHC, out=mass of hydrocarbon exiting the enclosure...

  6. 40 CFR 86.117-96 - Evaporative emission enclosure calibrations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... this section. (v) r=FID response factor to methanol. (vi) PB=Barometric pressure, in. Hg. (kPa). (vii) T=Enclosure ambient temperature, R(K). (viii) i=Indicates initial reading. (ix) f=Indicates final reading. (x)(A) k=3.05. (B) For SI units, k=17.60. (xi) MHC, out=mass of hydrocarbon exiting the enclosure...

  7. Physics and Psychophysics of High-Fidelity Sound. Part III: The Components of a Sound-Reproducing System: Amplifiers and Loudspeakers.

    ERIC Educational Resources Information Center

    Rossing, Thomas D.

    1980-01-01

    Described are the components for a high-fidelity sound-reproducing system which focuses on various program sources, the amplifier, and loudspeakers. Discussed in detail are amplifier power and distortion, air suspension, loudspeaker baffles and enclosures, bass-reflex enclosure, drone cones, rear horn and acoustic labyrinth enclosures, horn…

  8. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its dome must be enclosed by the vessel's hull structure or a separate steel cover. (b) The steel cover for... 46 Shipping 5 2012-10-01 2012-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section...

  9. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its dome must be enclosed by the vessel's hull structure or a separate steel cover. (b) The steel cover for... 46 Shipping 5 2013-10-01 2013-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section...

  10. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its dome must be enclosed by the vessel's hull structure or a separate steel cover. (b) The steel cover for... 46 Shipping 5 2010-10-01 2010-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section...

  11. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its dome must be enclosed by the vessel's hull structure or a separate steel cover. (b) The steel cover for... 46 Shipping 5 2014-10-01 2014-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section...

  12. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its dome must be enclosed by the vessel's hull structure or a separate steel cover. (b) The steel cover for... 46 Shipping 5 2011-10-01 2011-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section...

  13. In-situ characterization of wildland fire behavior

    Treesearch

    Bret Butler; D. Jimenez; J. Forthofer; Paul Sopko; K. Shannon; Jim Reardon

    2010-01-01

    A system consisting of two enclosures has been developed to characterize wildand fire behavior: The first enclosure is a sensor/data logger combination that measures and records convective/radiant energy released by the fire. The second is a digital video camera housed in a fire proof enclosure that records visual images of fire behavior. Together this system provides...

  14. Enclosures Abound: Black Cultural Autonomy, Prison Regime and Public Education

    ERIC Educational Resources Information Center

    Schnyder, Damien

    2010-01-01

    Since slavery, attempted enclosures upon Black spaces of cultural production and autonomy (i.e. music, language, art) have manifested in various forms. In the context of the post-industrial terrain of urban southern California, the formation of the prison is the dominant model of forced enclosure in the lives of Black people. Moving beyond the…

  15. Method and technique for installing light-weight, fragile, high-temperature fiber insulation

    NASA Technical Reports Server (NTRS)

    Patel, B. C. (Inventor)

    1983-01-01

    A method of installing fragile, light weight, high temperature fiber insulation, particularly where the insulation is to be used as a seal strip providing a high order of thermal barrier insulation is discussed. The process is based on provision of a strip of the mineral batting cut oversize by a predetermined amount, saturated in a fugitive polymer solution, compressed in a mold, dried and cured to form a rigidized batting material which is machined to required shape. The machine dimensions would normally be at least nominally less than the dimensions of the cavity to be sealed. After insertion in the cavity, which may be a wire-mesh seal enclosure, the apparatus is subjected to baking at a temperature sufficiently high to cause the resin to burn off cleanly, leaving the batting substantially in its original condition and expanded into the cavity or seal enclosure.

  16. A method and technique for installing light-weight fragile, high-temperature fiber insulation

    NASA Technical Reports Server (NTRS)

    Ballantine, T. J. (Inventor)

    1982-01-01

    A method of installing fragile, light-weight, high-temperature fiber insulation, particularly where the insulation is to be used as a seal strip providing a high order of thermal barrier insulation is described. The process is based on provision of a strip of the mineral batting cut oversize by a predetermined amount, saturated in a fugitive polymer solution, compressed in a mold, dried and cured to form a rigidized batting material which may be machined to required shape. The machined dimensions would normally be at least nominally less than the dimensions of the cavity to be sealed. After insertion in the cavity, which may be a wire-mesh seal enclosure, the apparatus is subjected to baking at a temperature sufficiently high to cause the resin to burn off cleanly, leaving the batting substantially in its original condition and expanded into the cavity or seal enclosure.

  17. Lethality and bioaccumulation of 4-nonylphenol in bluegill sunfish in littoral enclosures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liber, K.; Gangl, J.A.; Corry, T.D.

    1999-03-01

    Toxicity and bioaccumulation in bluegill sunfish (Lepomis macrochirus) of 4-nonylphenol (NP), a common precursor and degradation intermediate of certain nonionic surfactants, were evaluated in a set of 18 aquatic mesocosms (littoral enclosures) in northeastern Minnesota. Nonylphenol was applied to enclosures every 48 h over a 20-d period (11 applications) at rates of 3, 30, 100, and 300 {micro}g/L. Additional enclosures served as untreated controls. Maximum NP levels in the integrated water column 2 h after each application averaged 5 {+-} 4, 23 {+-} 11, 76 {+-} 21, and 243 {+-} 41 {micro}g/L over the 11 applications at the 3-, 30-,more » 100-, and 300-{micro}g/L treatments, respectively. Sixty-one percent of the NP dissipated from the water column within {approximately} 39 h of each application. Estimated survival of stocked juvenile bluegills was significantly reduced at the 300-{micro}g/L NP treatment. No significant effects were noted at the other NP treatments; however, the 100-{micro}g/L enclosure with the highest mean NP concentration (93 {+-} 39 {micro}g/L) within that treatment had four to nine times more dead bluegills and four to six times fewer bluegills captured at the end of the season than the other two 100-{micro}g/L enclosures (64 {+-} 23 and 71 {+-} 32 {micro}g/L) and the controls, suggesting increased mortality in this enclosure. Nonylphenol tissue concentrations in juvenile bluegills collected from enclosures treated with 3 and 30 {micro}g/L NP ranged from 0.01 to 2.94 {micro}g/g wet weight and showed a significant positive relationship with the average measured NP concentration in the water. The mean wet weight nonequilibrium NP bioaccumulation factor was 87 {+-} 124. There was no relationship between fish lipid content and NP tissue concentration.« less

  18. Enclosure Transform for Interest Point Detection From Speckle Imagery.

    PubMed

    Yongjian Yu; Jue Wang

    2017-03-01

    We present a fast enclosure transform (ET) to localize complex objects of interest from speckle imagery. This approach explores the spatial confinement on regional features from a sparse image feature representation. Unrelated, broken ridge features surrounding an object are organized collaboratively, giving rise to the enclosureness of the object. Three enclosure likelihood measures are constructed, consisting of the enclosure force, potential energy, and encloser count. In the transform domain, the local maxima manifest the locations of objects of interest, for which only the intrinsic dimension is known a priori. The discrete ET algorithm is computationally efficient, being on the order of O(MN) using N measuring distances across an image of M ridge pixels. It involves easy and few parameter settings. We demonstrate and assess the performance of ET on the automatic detection of the prostate locations from supra-pubic ultrasound images. ET yields superior results in terms of positive detection rate, accuracy and coverage.

  19. Protection of lithographic components from particle contamination

    DOEpatents

    Klebanoff, Leonard E.; Rader, Daniel J.

    2000-01-01

    A system that employs thermophoresis to protect lithographic surfaces from particle deposition and operates in an environment where the pressure is substantially constant and can be sub-atmospheric. The system (thermophoretic pellicle) comprises an enclosure that surrounds a lithographic component whose surface is being protected from particle deposition. The enclosure is provided with means for introducing a flow of gas into the chamber and at least one aperture that provides for access to the lithographic surface for the entry and exit of a beam of radiation, for example, and further controls gas flow into a surrounding low pressure environment such that a higher pressure is maintained within the enclosure and over the surface being protected. The lithographic component can be heated or, alternatively the walls of the enclosure can be cooled to establish a temperature gradient between the surface of the lithographic component and the walls of the enclosure, thereby enabling the thermophoretic force that resists particle deposition.

  20. Flows and Stratification of an Enclosure Containing Both Localised and Vertically Distributed Sources of Buoyancy

    NASA Astrophysics Data System (ADS)

    Partridge, Jamie; Linden, Paul

    2013-11-01

    We examine the flows and stratification established in a naturally ventilated enclosure containing both a localised and vertically distributed source of buoyancy. The enclosure is ventilated through upper and lower openings which connect the space to an external ambient. Small scale laboratory experiments were carried out with water as the working medium and buoyancy being driven directly by temperature differences. A point source plume gave localised heating while the distributed source was driven by a controllable heater mat located in the side wall of the enclosure. The transient temperatures, as well as steady state temperature profiles, were recorded and are reported here. The temperature profiles inside the enclosure were found to be dependent on the effective opening area A*, a combination of the upper and lower openings, and the ratio of buoyancy fluxes from the distributed and localised source Ψ =Bw/Bp . Industrial CASE award with ARUP.

  1. Natural convection in a cubical cavity with a coaxial heated cylinder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aithal, S. M.

    High-resolution three-dimensional simulations were conducted to investigate the velocity and temperature fields in a cold cubical cavity due to natural convection induced by a centrally placed hot cylinder. Unsteady, incompressible Navier-Stokes equations were solved by using a spectral- element method for Rayleigh numbers ranging from 103 to 109. The effect of spanwise thermal boundary conditions, aspect ratio (radius of the cylinder to the side of the cavity), and spanwise temperature distribution of the inner cylinder on the velocity and thermal fields were investigated for each Rayleigh number. Results from two-dimensional calculations were compared with three-dimensional simulations. The 3D results indicatemore » a complex flow structure in the vicinity of the spanwise walls. The results also show that the imposed thermal wall boundary condition impacts the flow and temperature fields strongly near the spanwise walls. The variation of the local Nusselt number on the cylinder surface and enclosure walls at various spanwise locations was also investigated. The local Nusselt number on the cylinder surface and enclosure walls at the cavity mid-plane (Z = 0) is close to 2D simulations for 103 ≤ Ra ≤ 108. Simulations also show a variation in the local Nusselt number, on both the cylinder surface and the enclosure walls, in the spanwise direction, for all Rayleigh numbers studied in this work. The results also indicate that if the enclosure walls are insulated in the spanwise direction (as opposed to a constant temperature), the peak Nusselt number on the enclosure surface occurs near the spanwise walls and is about 20% higher than the peak Nusselt number at the cavity mid-plane. The temporal characteristics of 3D flows are also different from 2D results for Ra > 108. These results suggest that 3D simulations would be more appropriate for flows with Ra > 108.« less

  2. Evaluation of a method to quantify glassy-winged sharpshooter (Hemiptera: Cicadellidae) egg maturation during a feeding assay

    USDA-ARS?s Scientific Manuscript database

    Methods to improve an assay relating adult feeding to egg maturation by the glassy-winged sharpshooter (Hemiptera: Cicadellidae) were evaluated. The assay consisted of confining adult females to cowpea stems in parafilm enclosures and quantifying adult feeding and egg maturation. Adult feeding was...

  3. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral... power systems. For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power systems, the following methods of grounding will...

  4. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral... power systems. For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power systems, the following methods of grounding will...

  5. 30 CFR 77.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... receiving power from ungrounded alternating current power systems. 77.701-1 Section 77.701-1 Mineral... power systems. For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power systems, the following methods of grounding will...

  6. 9 CFR 3.14 - Primary enclosures used to transport live dogs and cats.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... live dogs and cats. 3.14 Section 3.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... without tilting it, and ensure that anyone handling the enclosure will not come into physical contact with... enclosure is nontoxic to the animal and not harmful to the health or well-being of the animal; (8) Proper...

  7. 9 CFR 3.14 - Primary enclosures used to transport live dogs and cats.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... live dogs and cats. 3.14 Section 3.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... without tilting it, and ensure that anyone handling the enclosure will not come into physical contact with... enclosure is nontoxic to the animal and not harmful to the health or well-being of the animal; (8) Proper...

  8. 9 CFR 3.14 - Primary enclosures used to transport live dogs and cats.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... live dogs and cats. 3.14 Section 3.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... without tilting it, and ensure that anyone handling the enclosure will not come into physical contact with... enclosure is nontoxic to the animal and not harmful to the health or well-being of the animal; (8) Proper...

  9. 5. Exterior view, enclosure at walkin entry level between Test ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Exterior view, enclosure at walk-in entry level between Test Cell 6 (right) and Test Cell 7 (left), Systems Integration Laboratory Building (T-28), looking southwest. High pressure gas tank and generator test firings are conducted in the enclosure. - Air Force Plant PJKS, Systems Integration Laboratory, Systems Integration Laboratory Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  10. Molten carbonate fuel cell

    DOEpatents

    Kaun, Thomas D.; Smith, James L.

    1987-01-01

    A molten electrolyte fuel cell with an array of stacked cells and cell enclosures isolating each cell except for access to gas manifolds for the supply of fuel or oxidant gas or the removal of waste gas, the cell enclosures collectively providing an enclosure for the array and effectively avoiding the problems of electrolyte migration and the previous need for compression of stack components, the fuel cell further including an inner housing about and in cooperation with the array enclosure to provide a manifold system with isolated chambers for the supply and removal of gases. An external insulated housing about the inner housing provides thermal isolation to the cell components.

  11. Molten carbonate fuel cell

    DOEpatents

    Kaun, T.D.; Smith, J.L.

    1986-07-08

    A molten electrolyte fuel cell is disclosed with an array of stacked cells and cell enclosures isolating each cell except for access to gas manifolds for the supply of fuel or oxidant gas or the removal of waste gas. The cell enclosures collectively provide an enclosure for the array and effectively avoid the problems of electrolyte migration and the previous need for compression of stack components. The fuel cell further includes an inner housing about and in cooperation with the array enclosure to provide a manifold system with isolated chambers for the supply and removal of gases. An external insulated housing about the inner housing provides thermal isolation to the cell components.

  12. Electrical connection structure for a superconductor element

    DOEpatents

    Lallouet, Nicolas; Maguire, James

    2010-05-04

    The invention relates to an electrical connection structure for a superconductor element cooled by a cryogenic fluid and connected to an electrical bushing, which bushing passes successively through an enclosure at an intermediate temperature between ambient temperature and the temperature of the cryogenic fluid, and an enclosure at ambient temperature, said bushing projecting outside the ambient temperature enclosure. According to the invention, said intermediate enclosure is filled at least in part with a solid material of low thermal conductivity, such as a polyurethane foam or a cellular glass foam. The invention is applicable to connecting a superconductor cable at cryogenic temperature to a device for equipment at ambient temperature.

  13. Neutronic fuel element fabrication

    DOEpatents

    Korton, George

    2004-02-24

    This disclosure describes a method for metallurgically bonding a complete leak-tight enclosure to a matrix-type fuel element penetrated longitudinally by a multiplicity of coolant channels. Coolant tubes containing solid filler pins are disposed in the coolant channels. A leak-tight metal enclosure is then formed about the entire assembly of fuel matrix, coolant tubes and pins. The completely enclosed and sealed assembly is exposed to a high temperature and pressure gas environment to effect a metallurgical bond between all contacting surfaces therein. The ends of the assembly are then machined away to expose the pin ends which are chemically leached from the coolant tubes to leave the coolant tubes with internal coolant passageways. The invention described herein was made in the course of, or under, a contract with the U.S. Atomic Energy Commission. It relates generally to fuel elements for neutronic reactors and more particularly to a method for providing a leak-tight metal enclosure for a high-performance matrix-type fuel element penetrated longitudinally by a multiplicity of coolant tubes. The planned utilization of nuclear energy in high-performance, compact-propulsion and mobile power-generation systems has necessitated the development of fuel elements capable of operating at high power densities. High power densities in turn require fuel elements having high thermal conductivities and good fuel retention capabilities at high temperatures. A metal clad fuel element containing a ceramic phase of fuel intimately mixed with and bonded to a continuous refractory metal matrix has been found to satisfy the above requirements. Metal coolant tubes penetrate the matrix to afford internal cooling to the fuel element while providing positive fuel retention and containment of fission products generated within the fuel matrix. Metal header plates are bonded to the coolant tubes at each end of the fuel element and a metal cladding or can completes the fuel-matrix enclosure by encompassing the sides of the fuel element between the header plates.

  14. The 3.5-meter telescope enclosure

    NASA Astrophysics Data System (ADS)

    Brady, Michael H.

    1994-04-01

    The 3.5-m telescope enclosure is designed to perform two functions as part of the U.S. Air Force's 3.5-m telescope system: (1) to provide weather and temperature protection when the telescope is not in use and (2) to permit open-air operation of the telescope while minimizing atmospheric disturbances in the field of view (FOV). The use of a standard rotating dome is impractical because of the large telescope and its high rotational rate and acceleration. The enclosure is a 40-ft tall cylinder with a diameter of 72 ft. This steel and aluminum structure does not rotate but collapses vertically to fully expose the telescope to the open air and to provide it with an unobscured view of the horizon at all azimuthal angles. To lessen wind disturbances in the FOV, the enclosure has a moderately sloped roof and smooth, vertical walls. To minimize thermal flow, the outer surface has a high-reflectivity, low-emissivity coating and ambient air is forced through the double-skinned walls and roof. These measures make it possible to keep the enclosure surface temperature near that of the ambient air during viewing. With these features, the enclosure adds minimal degradation to the seeing.

  15. EXPERIMENTAL ANIMAL MAINTENANCE

    DOEpatents

    Finkel, M.P.

    1962-01-22

    A method of housing experimental animals such as mice in individual tube- like plastic enclosures is described. Contrary to experience, when this was tried with metal the mice did not become panicky. Group housing, with its attendant difficulties, may thus be dispensed with. (AEC)

  16. Persistence and distribution of 4-nonylphenol in water, sediment, macrophytes, and wall material of littoral enclosures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heinis, L.J.; Tunell, R.; Liber, K.

    1994-12-31

    Eighteen enclosures (5 m x 10 m) were constructed in the littoral zone of a 2-ha pond near Duluth, MN. Each enclosure consisted of 5 m of natural shoreline and three walls of an inert plastic. The enclosures had an average surface area of 31.9 m{sup 2} , an average depth of 0.6 m and an average water volume of 33.1 m{sup 3}. The enclosure waters were treated with the alkyl phenol ethoxylate precursor and degradation product 4-nonylphenol. Application was accomplished by sub-surface injection over a 20-day period with a 2 day frequency. Nominal aqueous concentrations were 0, 3, 30,more » 100 and 300 {mu}g/L. Concentrations of 4-nonylphenol were monitored during and after application in the water, sediment, macrophytes, and enclosure wall material. Average maximum water concentrations ranged from 96.5% of nominal to 62.0% of nominal and average minimum water concentrations ranged from 33.3% of nominal to 29.5% of nominal during the application period. Water concentrations decreased exponentially after application ended. Sediment concentrations during the application period were constant from 8 to 20 d and peak concentrations occurred 48 d after application began. Macrophyte concentrations peaked 21 d after initial application with a steady decline through 76 d. Enclosure wall material concentrations reached a peak 3 h before the final application. A gradual decline occurred until 34 d after initial application followed by a more rapid dissipation.« less

  17. Solidification of a binary alloy: Finite-element, single-domain simulation and new benchmark solutions

    NASA Astrophysics Data System (ADS)

    Le Bars, Michael; Worster, M. Grae

    2006-07-01

    A finite-element simulation of binary alloy solidification based on a single-domain formulation is presented and tested. Resolution of phase change is first checked by comparison with the analytical results of Worster [M.G. Worster, Solidification of an alloy from a cooled boundary, J. Fluid Mech. 167 (1986) 481-501] for purely diffusive solidification. Fluid dynamical processes without phase change are then tested by comparison with previous numerical studies of thermal convection in a pure fluid [G. de Vahl Davis, Natural convection of air in a square cavity: a bench mark numerical solution, Int. J. Numer. Meth. Fluids 3 (1983) 249-264; D.A. Mayne, A.S. Usmani, M. Crapper, h-adaptive finite element solution of high Rayleigh number thermally driven cavity problem, Int. J. Numer. Meth. Heat Fluid Flow 10 (2000) 598-615; D.C. Wan, B.S.V. Patnaik, G.W. Wei, A new benchmark quality solution for the buoyancy driven cavity by discrete singular convolution, Numer. Heat Transf. 40 (2001) 199-228], in a porous medium with a constant porosity [G. Lauriat, V. Prasad, Non-darcian effects on natural convection in a vertical porous enclosure, Int. J. Heat Mass Transf. 32 (1989) 2135-2148; P. Nithiarasu, K.N. Seetharamu, T. Sundararajan, Natural convective heat transfer in an enclosure filled with fluid saturated variable porosity medium, Int. J. Heat Mass Transf. 40 (1997) 3955-3967] and in a mixed liquid-porous medium with a spatially variable porosity [P. Nithiarasu, K.N. Seetharamu, T. Sundararajan, Natural convective heat transfer in an enclosure filled with fluid saturated variable porosity medium, Int. J. Heat Mass Transf. 40 (1997) 3955-3967; N. Zabaras, D. Samanta, A stabilized volume-averaging finite element method for flow in porous media and binary alloy solidification processes, Int. J. Numer. Meth. Eng. 60 (2004) 1103-1138]. Finally, new benchmark solutions for simultaneous flow through both fluid and porous domains and for convective solidification processes are presented, based on the similarity solutions in corner-flow geometries recently obtained by Le Bars and Worster [M. Le Bars, M.G. Worster, Interfacial conditions between a pure fluid and a porous medium: implications for binary alloy solidification, J. Fluid Mech. (in press)]. Good agreement is found for all tests, hence validating our physical and numerical methods. More generally, the computations presented here could now be considered as standard and reliable analytical benchmarks for numerical simulations, specifically and independently testing the different processes underlying binary alloy solidification.

  18. Industrial universal electrometer

    DOEpatents

    Cordaro, Joseph V [Martinez, GA; Wood, Michael B [Aiken, SC

    2012-07-03

    An electrometer for use in measuring current is provided. The electrometer includes an enclosure capable of containing various components of the electrometer. A pre-amplifier is present and is one of the components of the electrometer. The pre-amplifier is contained by the enclosure. The pre-amplifier has a pre-amplifier enclosure that contains the pre-amplifier and provides radio frequency shielding and magnetic shielding to the pre-amplifier.

  19. Operation HUSKY July-August, 1943

    DTIC Science & Technology

    1943-08-01

    degrees East. ( c ) On the Southwest, by a line drawn one one zero degrees from POINT SPAD - ILLO (PANTELLARIA). (d) On the Southeast, by a line drawn two...ABSTRACT SAR 18. NUMBER OF PAGES 142 19a. NAME OF RESPONSIBLE PERSON a. REPORT unclassified b. ABSTRACT unclassified c . THIS PAGE...117 — 127 ENCLOSURE (A) SICILY — BEACH DATA ENCLOSURE (B) ASSAULT TRANSPORT ROUTES ENCLOSURE ( C ) ASSAULT TRANSPORT ROUTES

  20. Fire safety evaluation of aircraft lavatory and cargo compartments

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Hilado, C. J.; Anderson, R. A.; Tustin, E.; Arnold, D. E.; Gaume, J. G.; Binding, A. T.; Mikeska, J. L.

    1975-01-01

    Large-scale aircraft lavatory and cargo compartment fire tests are described. Tests were conducted to evaluate the effectiveness of these compartments to contain fire and smoke. Two tests were conducted and are detailed. Test 1 involved a production Boeing 747 lavatory of the latest design installed in an enclosure outside the aircraft, to collect gases and expose animals to these gases. Results indicate that the interior of the lavatory was completely burned, evolving smoke and combustion products in the enclosure. Test 2 involved a simulated Douglas DC-10 cargo compartment retro-fitted with standard fiberglass liner. The fire caused excessive damage to the liner and burned through the ceiling in two areas. Test objectives, methods, materials, and results are presented and discussed.

  1. Pyrometer

    NASA Technical Reports Server (NTRS)

    Quince, Asia N. (Inventor); Stein, Alexander (Inventor)

    2015-01-01

    A non-contact pyrometer and method for calibrating the same are provided. The pyrometer includes a radiation sensor configured to measure at least a portion of a radiance signal emitted from a target medium and output a voltage that is a function of an average of the absorbed radiance signal, and an optical window disposed proximate the radiation sensor and configured to control a wavelength range of the radiance signal that reaches the radiation sensor. The pyrometer may further include a reflective enclosure configured to receive the target medium therein, wherein the radiation sensor and the optical window are disposed within the reflective enclosure, an amplifier in communication with an output of the radiation sensor, and a data acquisition system in communication with an output of the amplifier.

  2. CO-AXIAL DISCHARGES

    DOEpatents

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  3. Controlling toxic cyanobacteria: effects of dredging and phosphorus-binding clay on cyanobacteria and microcystins.

    PubMed

    Lürling, Miquel; Faassen, Elisabeth J

    2012-04-01

    Sediment dredging and Phoslock(®) addition were applied individually and in combination in an enclosure experiment in a Dutch hypertrophic urban pond. These measures were applied to control eutrophication and reduce the risk of exposure to cyanobacterial toxins. Over the 58 days course of the experiment, cyanobacteria (predominantly Microcystis aeruginosa) gradually decreased until they dropped below the level of detection in the combined treated enclosures, they were reduced in dredged enclosures, but remained flourishing in controls and Phoslock(®) treated enclosures. Cyanobacteria were, however, less abundant in the enclosures (medians chlorophyll-a 30-87 μg l(-1)) than in the pond (median chlorophyll-a 162 μg l(-1)), where also a thick surface scum covered one-third of the pond for many weeks. Soluble reactive phosphorus (SRP), total phosphorus and total nitrogen concentrations were significantly lower in the combined dredged and Phoslock(®) treated enclosures than in controls. Median SRP concentrations were 24 μg P l(-1) in the combined treatment, 58 μg P l(-1) in dredged enclosures, and 90 μg P l(-1) in controls and 95 μg P l(-1) in Phoslock(®) treated enclosures. Hence, the combined treatment was most effective in decreasing SRP and TP, and in lowering cyanobacterial biomass. Microcystin (MC) concentrations were analyzed by LC-MS/MS. MC concentrations and cyanobacterial biomass were positively correlated in all treatments. Mean MC concentrations in controls (71 μg l(-1)), Phoslock(®) treated enclosures (37 μg l(-1)) and dredged enclosures (25 μg l(-1)) exceeded the provisional guideline of 20 μg l(-1), whereas mean MC concentrations were 13 μg l(-1) in the combined treated enclosures. All samples contained the MC variants dmMC-RR, MC-RR, MC-YR, dmMC-LR and MC-LR; traces of MC-LY and nodularin were detected in few samples. The different treatments did not change the relative contribution of the variants to the MC pool; MC profiles in all treatments and the pond showed dominance of MC-RR followed by MC-LR. In the surface scum of the pond, total MC concentration was extremely high (64000 μg l(-1) or 1300 μg g(-1) DW), which poses a serious health hazard to children playing on the banks of the pond. Based on our results and pond characteristics, we propose combined sediment dredging and Phoslock(®) addition, fish removal and strong reduction of duck feeding by the neighborhood as most promising measures controlling cyanobacterial hazards in this pond. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Thermal enclosures for electronically scanned pressure modules operating in cryogenic environments

    NASA Technical Reports Server (NTRS)

    Mitchell, Michael; Sealey, Bradley S.

    1989-01-01

    Specific guidelines to design, construct, and test ESP thermal enclosures for applications at cryogenic temperatures are given. The enclosures maintain the ESP modules at a constant temperature (10 C plus or minus 1 C) to minimize thermal zero and sensitivity shifts, to minimize the frequency of expensive on-line calibrations, and to avoid adverse effects on tunnel and model boundary layers. The enclosures are constructed of a rigid closed-cell foam and are capable of withstanding the stagnation pressures to 932kPa (135 psia) without reduction in thermal insulation properties. This construction procedure has been used to construct several thermal packages which have been successfully used in National Transonic Facility.

  5. InfuShield: a shielded enclosure for administering therapeutic radioisotope treatments using standard syringe pumps

    PubMed Central

    Pratt, Brenda E.; Chittenden, Sarah J.; Murray, Iain S.; Causer, Louise; Grey, Matthew J.; Gear, Jonathan I.; Du, Yong; Flux, Glenn D.

    2017-01-01

    The administration of radionuclide therapies presents significant radiation protection challenges. The aim of this work was to develop a delivery system for intravenous radioisotope therapies to substantially moderate radiation exposures to staff and operators. A novel device (InfuShield) was designed and tested before being used clinically. The device consists of a shielded enclosure which contains the therapeutic activity and, through the hydraulic action of back-to-back syringes, allows the activity to be administered using a syringe pump external to the enclosure. This enables full access to the pump controls while simultaneously reducing dose to the operator. The system is suitable for use with all commercially available syringe pumps and does not require specific consumables, maximising both the flexibility and economy of the system. Dose rate measurements showed that at key stages in an 131I mIBG treatment procedure, InfuShield can reduce dose to operators by several orders of magnitude. Tests using typical syringes and infusion speeds show no significant alteration in administered flow rates (maximum of 1.2%). The InfuShield system provides a simple, safe and low cost method of radioisotope administration. PMID:28187040

  6. The propagation of sound in tunnels

    NASA Astrophysics Data System (ADS)

    Li, Kai Ming; Iu, King Kwong

    2002-11-01

    The sound propagation in tunnels is addressed theoretically and experimentally. In many previous studies, the image source method is frequently used. However, these early theoretical models are somewhat inadequate because the effect of multiple reflections in long enclosures is often modeled by the incoherent summation of contributions from all image sources. Ignoring the phase effect, these numerical models are unlikely to be satisfactory for predicting the intricate interference patterns due to contributions from each image source. In the present paper, the interference effect is incorporated by summing the contributions from the image sources coherently. To develop a simple numerical model, tunnels are represented by long rectangular enclosures with either geometrically reflecting or impedance boundaries. Scale model experiments are conducted for the validation of the numerical model. In some of the scale model experiments, the enclosure walls are lined with a carpet for simulating the impedance boundary condition. Large-scale outdoor measurements have also been conducted in two tunnels designed originally for road traffic use. It has been shown that the proposed numerical model agrees reasonably well with experimental data. [Work supported by the Research Grants Council, The Industry Department, NAP Acoustics (Far East) Ltd., and The Hong Kong Polytechnic University.

  7. Application of the relative energy release criteria to enclosure fire testing. [aircraft compartments

    NASA Technical Reports Server (NTRS)

    Roschke, E. J.; Coulbert, C. D.

    1979-01-01

    The five relative energy release criteria (RERC) which are a first step towards formulating a unified concept that can be applied to the development of fires in enclosures, place upper bounds on the rate and amount of energy released during a fire. They are independent, calculated readily, and may be applied generally to any enclosure regardless of size. They are useful in pretest planning and for interpreting experimental data. Data from several specific fire test programs were examined to evaluate the potential use of RERC to provide test planning guidelines. The RERC were compared with experimental data obtained in full-scale enclosures. These results confirm that in general the RERC do identify the proper limiting constraints on enclosure fire development and determine the bounds of the fire development envelope. Plotting actual fire data against the RERC reveals new valid insights into fire behavior and reveals the controlling constraints in fire development. The RERC were calculated and plotted for several descrpitions of full-scale fires in various aircraft compartments.

  8. Oxygen ingress study of 3D printed gaseous radiation detector enclosures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steer, Christopher A.; Durose, Aaron

    2015-07-01

    As part of our ongoing studies into the potential application of 3D printing techniques to gaseous radiation detectors, we have studied the ability of 3D printed enclosures to resist environmental oxygen ingress. A set of cuboid and hexagonal prism shaped enclosures with wall thicknesses of 4 mm, 6 mm, 8 mm and 10 mm were designed and printed in nylon using a EOSINT P 730 Selective Laser Sintering 3D printer system These test enclosures provide a comparison of different environmental gas ingress for different 3D printing techniques. The rate of change of oxygen concentration was found to be linear, decreasingmore » as the wall thickness increases. It was also found that the hexagonal prism geometry produced a lower rate of change of oxygen concentration compared with the cuboid shaped enclosures. Possible reasons as to why these results were obtained are discussed The implications for the this study for deployable systems are also discussed (authors)« less

  9. Emissions and Photochemistry of BVOCs in a Ponderosa Pine woodland

    NASA Astrophysics Data System (ADS)

    Kim, S.; Karl, T.; Rasmussen, R.; Apel, E.; Harley, P.; Waldo, S.; Roberts, S.; Guenther, A.

    2008-12-01

    We deployed two proton-transfer-reaction mass spectrometry instruments (PTR-MS, IONICON ANALYTIK) for ambient and branch enclosure measurements at the Manitou Experimental Forest, located in the Southern Rocky Mountain area as a part of the Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics and Nitrogen (BEACHON) field campaign in 2008. Vegetation at the field site is dominated by Ponderosa Pine. BVOC emissions from Ponderosa Pine along with temperature, photosynthetic photon flux density (ppfd), relative humidity, and CO2 uptake were measured from two branch-enclosures (shade and sun). Diurnal variations and the emission response to environmental conditions are described and compared to existing models. In addition, we analyzed the speciation of BVOCs from enclosures by GC-MS. We will present quantitative and qualitative characteristics of BVOC emissions from Ponderosa Pine and analytical characteristics of PTR-MS such as fragmentation patterns of semi-volatile compounds (sesquiterpene, bornyl acetate etc) that we identified as major emissions from the enclosures. BVOC emissions observed in the enclosures will be quantitatively compared to BVOC distributions in ambient air. We explore the presence of possibly unidentified BVOCs in the forest canopy by examining PTR-MS mass spectra of enclosure and ambient air samples based on mass scans between 40 - 210 amu.

  10. Changing environmental conditions and applying organic fertilizers in Origanum vulgare L.

    PubMed Central

    Murillo-Amador, Bernardo; Morales-Prado, Luis E.; Troyo-Diéguez, Enrique; Córdoba-Matson, Miguel V.; Hernández-Montiel, Luis G.; Rueda-Puente, Edgar O.; Nieto-Garibay, Alejandra

    2015-01-01

    Any improvement in agricultural systems that results in higher production should also reduce negative environmental impacts and enhance sustainability. The aim of this research was to investigate the effect of two different production systems, one open-field and the other shade-enclosure with four bocashi doses, in order to find the best environmental option in terms of yield, physiological and morphometric characteristics in one oregano (Origanum vulgare L.) cultivar. In this study a completely randomized block design was used with four replications and evaluated for photosynthetic and transpiration rate, stomatal conductance, chlorophyll, leaf area and temperature, aerial and roots fresh and dry biomass, fresh and dry yield. The results showed that oregano adapted best to the shade-enclosure with increase yield of fresh and dry leaf weight of 165% and 118%, respectively, when compared to open-field. Also, higher doses of bocashi improved yield in both environments but more so in shade-enclosure. Soil moisture retention was higher in shade-enclosure which was reflected in physiological variables for soil matric potential, transpiration, stomatal conductivity, photosynthesis being significantly higher in shade-enclosure compared to open-field, thus improving yield. It seems that oregano plants can be grown and perform better under shade-enclosure than open-field and bocashi is a suitable organic fertilizer. PMID:26257756

  11. Captive chimpanzee (Pan troglodytes) behavior as a function of space per animal and enclosure type.

    PubMed

    Neal Webb, Sarah J; Hau, Jann; Schapiro, Steven J

    2018-03-01

    Space per animal, or animal density, and enclosure type are important elements of functionally appropriate captive environments (FACEs) for chimpanzees. The National Institutes of Health (NIH) recommends that captive chimpanzees be maintained in areas of >250 ft 2 /animal. Several studies have investigated chimpanzee behavior in relation to space per animal, but only two studies have examined these variables while attempting to hold environmental complexity constant. Both have found few, if any, significant differences in behavior associated with increased space per animal. The NIH does not provide recommendations pertaining to enclosure type. Although Primadomes™ and corrals are considered acceptable FACE housing, no studies have investigated chimpanzee behavior in relation to these two common types of enclosures. We examined the NIH space per animal recommendation, and the effects of enclosure type, while maintaining similar levels of environmental complexity. We used focal animal observations to record the behavior of 22 chimpanzees in three social groups following within-facility housing transfers. Chimpanzees that were moved from an area with space below the NIH recommendation to the same type of enclosure with space above the recommendation (dome to double dome) exhibited significantly more locomotion and behavioral diversity post-transfer. Chimpanzees that were moved from an area with space below the recommendation to a different type of enclosure with space above the recommendation (dome to corral) exhibited significant increases in foraging and behavioral diversity, and a decrease in rough scratching. Lastly, chimpanzees that were moved from an area above the recommendation to a different enclosure type with space equal to the recommendation (corral to double dome) exhibited an increase in behavioral diversity. These results add to the body of literature that addresses the concept of specific minimum space requirements per chimpanzee, and highlight the need for more empirical investigation of the relationship between space per chimpanzee, behavior, and welfare. © 2018 Wiley Periodicals, Inc.

  12. Unsteady wind loads for TMT: replacing parametric models with CFD

    NASA Astrophysics Data System (ADS)

    MacMartin, Douglas G.; Vogiatzis, Konstantinos

    2014-08-01

    Unsteady wind loads due to turbulence inside the telescope enclosure result in image jitter and higher-order image degradation due to M1 segment motion. Advances in computational fluid dynamics (CFD) allow unsteady simulations of the flow around realistic telescope geometry, in order to compute the unsteady forces due to wind turbulence. These simulations can then be used to understand the characteristics of the wind loads. Previous estimates used a parametric model based on a number of assumptions about the wind characteristics, such as a von Karman spectrum and frozen-flow turbulence across M1, and relied on CFD only to estimate parameters such as mean wind speed and turbulent kinetic energy. Using the CFD-computed forces avoids the need for assumptions regarding the flow. We discuss here both the loads on the telescope that lead to image jitter, and the spatially-varying force distribution across the primary mirror, using simulations with the Thirty Meter Telescope (TMT) geometry. The amplitude, temporal spectrum, and spatial distribution of wind disturbances are all estimated; these are then used to compute the resulting image motion and degradation. There are several key differences relative to our earlier parametric model. First, the TMT enclosure provides sufficient wind reduction at the top end (near M2) to render the larger cross-sectional structural areas further inside the enclosure (including M1) significant in determining the overall image jitter. Second, the temporal spectrum is not von Karman as the turbulence is not fully developed; this applies both in predicting image jitter and M1 segment motion. And third, for loads on M1, the spatial characteristics are not consistent with propagating a frozen-flow turbulence screen across the mirror: Frozen flow would result in a relationship between temporal frequency content and spatial frequency content that does not hold in the CFD predictions. Incorporating the new estimates of wind load characteristics into TMT response predictions leads to revised estimates of the response of TMT to wind turbulence, and validates the aerodynamic design of the enclosure.

  13. 40 CFR 63.5895 - How do I monitor and collect data to demonstrate continuous compliance?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... combination of an individual resin or gel coat, application method, and controls meets its applicable emission... pultrusion machines, you must record all times that wet area enclosures doors or covers are open and there is...

  14. 49 CFR 193.2905 - Protective enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... surrounded by a protective enclosure: (1) Storage tanks; (2) Impounding systems; (3) Vapor barriers; (4...

  15. Rack for storing spent nuclear fuel elements

    DOEpatents

    Rubinstein, Herbert J.; Clark, Philip M.; Gilcrest, James D.

    1978-06-20

    A rack for storing spent nuclear fuel elements in which a plurality of aligned rows of upright enclosures of generally square cross-sectional areas contain vertically disposed fuel elements. The enclosures are fixed at the lower ends thereof to a base. Pockets are formed between confronting walls of adjacent enclosures for receiving high absorption neutron absorbers, such as Boral, cadmium, borated stainless steel and the like for the closer spacing of spent fuel elements.

  16. Fischer-Tropsch Cobalt Catalyst Activation and Handling Through Wax Enclosure Methods

    NASA Technical Reports Server (NTRS)

    Klettlinger, Jennifer L. S.; Yen, Chia H.; Nakley, Leah M.; Surgenor, Angela D.

    2016-01-01

    Fischer-Tropsch (F-T) synthesis is considered a gas to liquid process which converts syn-gas, a gaseous mixture of hydrogen and carbon monoxide, into liquids of various hydrocarbon chain length and product distributions. Cobalt based catalysts are used in F-T synthesis and are the focus of this paper. One key concern with handling cobalt based catalysts is that the active form of catalyst is in a reduced state, metallic cobalt, which oxidizes readily in air. In laboratory experiments, the precursor cobalt oxide catalyst is activated in a fixed bed at 350 ?C then transferred into a continuous stirred tank reactor (CSTR) with inert gas. NASA has developed a process which involves the enclosure of active cobalt catalyst in a wax mold to prevent oxidation during storage and handling. This improved method allows for precise catalyst loading and delivery into a CSTR. Preliminary results indicate similar activity levels in the F-T reaction in comparison to the direct injection method. The work in this paper was supported by the NASA Fundamental Aeronautics Subsonics Fixed Wing Project.

  17. Parallel Processing of Large Scale Microphone Arrays for Sound Capture

    NASA Astrophysics Data System (ADS)

    Jan, Ea-Ee.

    1995-01-01

    Performance of microphone sound pick up is degraded by deleterious properties of the acoustic environment, such as multipath distortion (reverberation) and ambient noise. The degradation becomes more prominent in a teleconferencing environment in which the microphone is positioned far away from the speaker. Besides, the ideal teleconference should feel as easy and natural as face-to-face communication with another person. This suggests hands-free sound capture with no tether or encumbrance by hand-held or body-worn sound equipment. Microphone arrays for this application represent an appropriate approach. This research develops new microphone array and signal processing techniques for high quality hands-free sound capture in noisy, reverberant enclosures. The new techniques combine matched-filtering of individual sensors and parallel processing to provide acute spatial volume selectivity which is capable of mitigating the deleterious effects of noise interference and multipath distortion. The new method outperforms traditional delay-and-sum beamformers which provide only directional spatial selectivity. The research additionally explores truncated matched-filtering and random distribution of transducers to reduce complexity and improve sound capture quality. All designs are first established by computer simulation of array performance in reverberant enclosures. The simulation is achieved by a room model which can efficiently calculate the acoustic multipath in a rectangular enclosure up to a prescribed order of images. It also calculates the incident angle of the arriving signal. Experimental arrays were constructed and their performance was measured in real rooms. Real room data were collected in a hard-walled laboratory and a controllable variable acoustics enclosure of similar size, approximately 6 x 6 x 3 m. An extensive speech database was also collected in these two enclosures for future research on microphone arrays. The simulation results are shown to be consistent with the real room data. Localization of sound sources has been explored using cross-power spectrum time delay estimation and has been evaluated using real room data under slightly, moderately and highly reverberant conditions. To improve the accuracy and reliability of the source localization, an outlier detector that removes incorrect time delay estimation has been invented. To provide speaker selectivity for microphone array systems, a hands-free speaker identification system has been studied. A recently invented feature using selected spectrum information outperforms traditional recognition methods. Measured results demonstrate the capabilities of speaker selectivity from a matched-filtered array. In addition, simulation utilities, including matched -filtering processing of the array and hands-free speaker identification, have been implemented on the massively -parallel nCube super-computer. This parallel computation highlights the requirements for real-time processing of array signals.

  18. 30 CFR 7.303 - Application requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... assembly. (2) Overall dimensions of the motor assembly, including conduit box if applicable, and internal... enclosure or enclosures. (4) All dimensions (including tolerances) and specifications required to ascertain...

  19. 30 CFR 7.303 - Application requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... assembly. (2) Overall dimensions of the motor assembly, including conduit box if applicable, and internal... enclosure or enclosures. (4) All dimensions (including tolerances) and specifications required to ascertain...

  20. 30 CFR 7.303 - Application requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... assembly. (2) Overall dimensions of the motor assembly, including conduit box if applicable, and internal... enclosure or enclosures. (4) All dimensions (including tolerances) and specifications required to ascertain...

  1. 30 CFR 7.303 - Application requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... assembly. (2) Overall dimensions of the motor assembly, including conduit box if applicable, and internal... enclosure or enclosures. (4) All dimensions (including tolerances) and specifications required to ascertain...

  2. SHIELDING CONSIDERATIONS FOR THE SMALL ANIMAL RADIATION RESEARCH PLATFORM (SARRP)

    PubMed Central

    Sayler, Elaine; Dolney, Derek; Avery, Stephen; Koch, Cameron

    2014-01-01

    The Small Animal Radiation Research Platform (SARRP) is a commercially available platform designed to deliver conformal, image-guided radiation to small animals using a dual-anode kV x-ray source. At the University of Pennsylvania, a free-standing 2 m3 enclosure was designed to shield the SARRP according to federal code regulating cabinet x-ray systems. The initial design consisted of 4.0-mm-thick lead for all secondary barriers and proved wholly inadequate. Radiation levels outside the enclosure were 15 times higher than expected. Additionally, the leakage appeared to be distributed broadly within the enclosure, so concern arose that a subject might receive significant doses outside the intended treatment field. Thus, a detailed analysis was undertaken to identify and block all sources of leakage. Leakage sources were identified by Kodak X-OmatV (XV) film placed throughout the enclosure. Radiation inside the enclosure was quantified using Gafchromic film. Outside the enclosure, radiation was measured using a survey meter. Sources of leakage included (1) an unnecessarily broad beam exiting the tube, (2) failure of the secondary collimator to confine the primary beam entirely, (3) scatter from the secondary collimator, (4) lack of beam-stop below the treatment volume, and (5) incomplete shielding of the x-ray tube. The exit window was restricted, and a new collimator was designed to address problems (1–3). A beam-stop and additional tube shielding were installed. These modifications reduced internal scatter by more than 100-fold. Radiation outside the enclosure was reduced to levels compliant with federal regulations, provided the SARRP is operated using tube potentials of 175 kV or less. In addition, these simple and relatively inexpensive modifications eliminate the possibility of exposing a larger animal (such as a rat) to significant doses outside the treatment field. PMID:23532076

  3. Kodiak: An Implementation Framework for Branch and Bound Algorithms

    NASA Technical Reports Server (NTRS)

    Smith, Andrew P.; Munoz, Cesar A.; Narkawicz, Anthony J.; Markevicius, Mantas

    2015-01-01

    Recursive branch and bound algorithms are often used to refine and isolate solutions to several classes of global optimization problems. A rigorous computation framework for the solution of systems of equations and inequalities involving nonlinear real arithmetic over hyper-rectangular variable and parameter domains is presented. It is derived from a generic branch and bound algorithm that has been formally verified, and utilizes self-validating enclosure methods, namely interval arithmetic and, for polynomials and rational functions, Bernstein expansion. Since bounds computed by these enclosure methods are sound, this approach may be used reliably in software verification tools. Advantage is taken of the partial derivatives of the constraint functions involved in the system, firstly to reduce the branching factor by the use of bisection heuristics and secondly to permit the computation of bifurcation sets for systems of ordinary differential equations. The associated software development, Kodiak, is presented, along with examples of three different branch and bound problem types it implements.

  4. Methods for multi-material stereolithography

    DOEpatents

    Wicker, Ryan [El Paso, TX; Medina, Francisco [El Paso, TX; Elkins, Christopher [Redwood City, CA

    2011-06-14

    Methods and systems of stereolithography for building cost-efficient and time-saving multi-material, multi-functional and multi-colored prototypes, models and devices configured for intermediate washing and curing/drying is disclosed including: laser(s), liquid and/or platform level sensing system(s), controllable optical system(s), moveable platform(s), elevator platform(s), recoating system(s) and at least one polymer retaining receptacle. Multiple polymer retaining receptacles may be arranged in a moveable apparatus, wherein each receptacle is adapted to actively/passively maintain a uniform, desired level of polymer by including a recoating device and a material fill/remove system. The platform is movably accessible to the polymer retaining receptacle(s), elevator mechanism(s) and washing and curing/drying area(s) which may be housed in a shielded enclosure(s). The elevator mechanism is configured to vertically traverse and rotate the platform, thus providing angled building, washing and curing/drying capabilities. A horizontal traversing mechanism may be included to facilitate manufacturing between components of SL cabinet(s) and/or alternative manufacturing technologies.

  5. Application of Monte Carlo techniques to transient thermal modeling of cavity radiometers having diffuse-specular surfaces

    NASA Technical Reports Server (NTRS)

    Mahan, J. R.; Eskin, L. D.

    1981-01-01

    A viable alternative to the net exchange method of radiative analysis which is equally applicable to diffuse and diffuse-specular enclosures is presented. It is particularly more advantageous to use than the net exchange method in the case of a transient thermal analysis involving conduction and storage of energy as well as radiative exchange. A new quantity, called the distribution factor is defined which replaces the angle factor and the configuration factor. Once obtained, the array of distribution factors for an ensemble of surface elements which define an enclosure permits the instantaneous net radiative heat fluxes to all of the surfaces to be computed directly in terms of the known surface temperatures at that instant. The formulation of the thermal model is described, as is the determination of distribution factors by application of a Monte Carlo analysis. The results show that when fewer than 10,000 packets are emitted, an unsatisfactory approximation for the distribution factors is obtained, but that 10,000 packets is sufficient.

  6. Convective flows in enclosures with vertical temperature or concentration gradients

    NASA Technical Reports Server (NTRS)

    Wang, L. W.; Chai, A. T.; Sun, D. J.

    1988-01-01

    The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.

  7. Convective flows in enclosures with vertical temperature or concentration gradients

    NASA Technical Reports Server (NTRS)

    Wang, L. W.; Chai, A. T.; Sun, D. J.

    1989-01-01

    The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.

  8. Natural Convection Immersion Cooling of an Array of Heated Protrusions in an Enclosure Filled with Dielectric Liquid: Effects of Enclosure Width and Fluid Prandtl Number

    DTIC Science & Technology

    1991-03-01

    ELEMENT NO. NO. NO. ACCESSION NO ’ A~rIECti fvMERSlON COOLING OF AN ARRAY OF HEATED PROTRUSIONS IN AN ENCLOSURE FILLED WITH DIELECTRIC LIQUID...341 10. SS7 6.779 S.S1S TEMP.BASED RAYLEIGH NUMBER - E-B IS: 2.13 FLUX BASED RAYLEIGH NUMBER - E-6 IS: 14.42 AVERAGE TEMPERATURE: 20.987 SINK TEMPERATURE

  9. KSC-02pd1148

    NASA Image and Video Library

    2002-07-25

    KENNEDY SPACE CENTER, FLA. -- In Vehicle Assembly Building (VAB) high bay 4, installation of a Payload Bay Door Drying Enclosure is in progress. The enclosure will keep moisture from being absorbed into the graphite epoxy used on the payload bay doors of the Shuttle orbiters with the assistance of mini-Portable Purge Units (PPUs). Once in operation, the enclosure will allow NASA the option to store an orbiter in the VAB bay up to 180 days in a "standby-to-stack" mode.

  10. KSC-02pd1147

    NASA Image and Video Library

    2002-07-25

    KENNEDY SPACE CENTER, FLA. -- In Vehicle Assembly Building (VAB) high bay 4, installation of a Payload Bay Door Drying Enclosure is in progress. The enclosure will keep moisture from being absorbed into the graphite epoxy used on the payload bay doors of the Shuttle orbiters with the assistance of mini-Portable Purge Units (PPUs). Once in operation, the enclosure will allow NASA the option to store an orbiter in the VAB bay up to 180 days in a "standby-to-stack" mode.

  11. KSC-02pd1150

    NASA Image and Video Library

    2002-07-26

    KENNEDY SPACE CENTER, FLA. -- -- In Vehicle Assembly Building (VAB) high bay 4, installation of a Payload Bay Door Drying Enclosure is in progress. The enclosure will keep moisture from being absorbed into the graphite epoxy used on the payload bay doors of the Shuttle orbiters with the assistance of mini-Portable Purge Units (PPUs). Once in operation, the enclosure will allow NASA the option to store an orbiter in the VAB bay up to 180 days in a "standby-to-stack" mode.

  12. Hubble Space Telescope servicing mission scientific instrument protective enclosure design requirements and contamination controls

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Hughes, David W.; Hedgeland, Randy J.; Chivatero, Craig J.; Studer, Robert J.; Kostos, Peter J.

    1994-01-01

    The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.

  13. Astronaut Scott Parazynski works with PCG experiment on middeck

    NASA Image and Video Library

    1994-11-14

    STS066-13-029 (3-14 Nov 1994) --- On the Space Shuttle Atlantis' mid-deck, astronaut Scott E. Parazynski, mission specialist, works at one of two areas onboard the Shuttle which support the Protein Crystal Growth (PCG) experiment. This particular section is called the Vapor Diffusion Apparatus (VDA), housed in a Single Locker Thermal Enclosure (STES). Together with the Crystal Observation System, housed in the Thermal Enclosure System (COS/TES) the VDA represents the continuing research into the structures of proteins and other macromolecules such as viruses. In addition to using the microgravity of space to grow high-quality protein crystals for structural analyses, the experiments are expected to help develop technologies and methods to improve the protein crystallization process on Earth as well as in space.

  14. NASA Animal Enclosure Module Mouse Odor Containment Study for STS-107 September 15, 1999;SJSU Odor Panel Data

    NASA Technical Reports Server (NTRS)

    Holley, Daniel C.; Mele, Gary D.; Poffenroth, Mary; Young, Cliff

    2000-01-01

    Experiment #153 by Scott Brady is manifested for shuttle flight STS-107. This evaluation of space flight induced stress and its effects on neuronal plasticity will use 18 six month old C57Bl/6 male mice. A 21 day evaluation study was proposed to determine the length of time groups of 6, 9, or 12 mice could be housed in the Animal Enclosure Module (AEM) without odor breakthrough. This study was performed at NASA-Ames Research Center beginning on September 15, 1999. NASA personnel, were responsible for animal care, maintenance, facilities, hardware, etc. San Jose State personnel performed the odor panel evaluations and data reduction. We used similar procedures and methods for earlier tests evaluating female mice.

  15. Cavity enhancement by controlled directional scattering

    NASA Astrophysics Data System (ADS)

    Winston, R.

    1980-01-01

    A method for designing cavity enclosures is presented that can be applied to the design of a nonimaging concentrator. The method maintains high transmission at the expense of some concentration in the presence of a gap between the reflector and the receiver. The slight loss of concentration may be partly offset by enhanced absorption of radiation by the receiver, resulting from the cavity effect.

  16. Phase change material storage heater

    DOEpatents

    Goswami, D. Yogi; Hsieh, Chung K.; Jotshi, Chand K.; Klausner, James F.

    1997-01-01

    A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

  17. Design and upgrades for the Sloan Digital Sky Survey telescope's roll-off enclosure

    NASA Astrophysics Data System (ADS)

    Leger, R. French; Long, Dan; Klaene, Mark A.

    2003-02-01

    The SDSS telescope is housed, when not in use, in a roll-off enclosure. This enclosure rolls away from the telescope a distance of 60 feet, leaving the telescope fully exposed for operations. Design considerations for wind and solar loading, thermal venting, conditioning and stability are reviewed. Originally, the enclosure had been constructed to minimize its surface area obstruction to the telescopes field of view. This design feature, however, offered little room to perform engineering tasks during non-operational time. An upgrade to the structure, in the form of raising the roof, was instituted. This improvement greatly enhanced the engineering and testing functions performed on the telescope, thereby increasing operational efficiency and the time allotted to engineering tasks. Problems maintaining and associated with weather sealing, lightning protection, truck wheel alignment, altitude effects on truck controllers and thermal conditioning are examined. Communication and electrical connections between stationary and moving elements of the enclosure are described. Two types of systems, to date, have been used one a reel and the other a slider system. Advantages and disadvantages of both are examined from the perspective of four years experience.

  18. On the suitability of steady RANS CFD for forced mixing ventilation at transitional slot Reynolds numbers.

    PubMed

    van Hooff, T; Blocken, B; van Heijst, G J F

    2013-06-01

    Accurate prediction of ventilation flow is of primary importance for designing a healthy, comfortable, and energy-efficient indoor environment. Since the 1970s, the use of computational fluid dynamics (CFD) has increased tremendously, and nowadays, it is one of the primary methods to assess ventilation flow in buildings. The most commonly used numerical approach consists of solving the steady Reynolds-averaged Navier-Stokes (RANS) equations with a turbulence model to provide closure. This article presents a detailed validation study of steady RANS for isothermal forced mixing ventilation of a cubical enclosure driven by a transitional wall jet. The validation is performed using particle image velocimetry (PIV) measurements for slot Reynolds numbers of 1000 and 2500. Results obtained with the renormalization group (RNG) k-ε model, a low-Reynolds k-ε model, the shear stress transport (SST) k-ω model, and a Reynolds stress model (RSM) are compared with detailed experimental data. In general, the RNG k-ε model shows the weakest performance, whereas the low-Re k-ε model shows the best agreement with the measurements. In addition, the influence of the turbulence model on the predicted air exchange efficiency in the cubical enclosure is analyzed, indicating differences up to 44% for this particular case. This article presents a detailed numerical study of isothermal forced mixing ventilation driven by a low-velocity (transitional) wall jet using steady computational fluid dynamics (CFD) simulations. It is shown that the numerically obtained room airflow patterns are highly dependent on the chosen turbulence model and large differences with experimentally obtained velocity fields can be present. The renormalization group (RNG) k-ε model, which is commonly used for room airflow modeling, shows the largest deviations from the measured velocities, indicating the care that must be taken when selecting a turbulence model for room airflow prediction. As a result of the different predictions of the flow pattern in the room, large differences are present between the predicted air exchange efficiency obtained with the four tested turbulence models, which can be as high as 44%. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  19. Radiative flux from a planar multiple point source within a cylindrical enclosure reaching a coaxial circular plane

    NASA Astrophysics Data System (ADS)

    Tryka, Stanislaw

    2007-04-01

    A general formula and some special integral formulas were presented for calculating radiative fluxes incident on a circular plane from a planar multiple point source within a coaxial cylindrical enclosure perpendicular to the source. These formula were obtained for radiation propagating in a homogeneous isotropic medium assuming that the lateral surface of the enclosure completely absorbs the incident radiation. Exemplary results were computed numerically and illustrated with three-dimensional surface plots. The formulas presented are suitable for determining fluxes of radiation reaching planar circular detectors, collectors or other planar circular elements from systems of laser diodes, light emitting diodes and fiber lamps within cylindrical enclosures, as well as small biological emitters (bacteria, fungi, yeast, etc.) distributed on planar bases of open nontransparent cylindrical containers.

  20. Numerical studies of convective heat transfer in an inclined semiannular enclosure

    NASA Technical Reports Server (NTRS)

    Wang, Lin-Wen; Yung, Chain-Nan; Chai, An-Ti; Rashidnia, Nasser

    1989-01-01

    Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

  1. Spatial-temporal evolution of the eastern Nanhui mudflat in the Changjiang (Yangtze River) Estuary under intensified human activities

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaodong; Zhang, Yexin; Zhu, Longhai; Chi, Wanqing; Yang, Zuosheng; Wang, Biying; Lv, Kai; Wang, Hongmin; Lu, Zhiyong

    2018-05-01

    The eastern Nanhui mudflat (ENM), located in the southern flank of the Changjiang (Yangtze River) Estuary, plays a key role in storm protection, defense against sea level rise, and land resource provision for Shanghai, China's largest city. Recently, there has been a great deal of concern for its evolutionary fate, since a drastic reduction in the Changjiang sediment discharge rate and an increased number of estuarine enclosures might negatively impact the environmental protection functions that this mudflat provides. In this paper, a novel method, which employed the envelope lines of instantaneous shoreline positions identified in 436 Landsat satellite images from 1975 to 2016, was used to demonstrate the evolution of the mudflat high and low tide lines in a detailed, quantitative way. Our study reveals the southeast progradation rate of the mudflat doubled from 24 m/yr in 713-1974 CE to 49 m/yr in 1975-1995 CE, probably due to the influence of the estuarine turbidity maximum zone shifting to the ENM. Under the ample sediment input directly from the turbidity maximum zone, the spatial evolution of the ENM was governed predominantly by the changing morphology of the South Passage due to the quick progradation of the ENM, which narrowed the South Passage by pushing the South Passage Trumpet southeastward. Therefore, the ENM experienced rapid accretion during 1975-2016. The accretion rate of the high tide line increased 2-13 times due to vegetation and intertidal enclosures, resulting in the rapid reduction of the intertidal area. The area decreased from 97 km2 in 1976 to 66 km2 in 1995, mainly due to vegetation, and continued decreasing to 12 km2 in 2006 due to the intertidal enclosures. In contrast, the accretion rate of the low tide line increased by 25 times due to subtidal enclosures and caused the intertidal area increased to 78 km2 in 2015. The almost disappeared intertidal zones in 2006 reappeared. However, this reappearance might be a temporary transitional state, and once the subtidal enclosures are completed, most of the intertidal zones will be replaced by enclosure land. Our study reveals that the drastic reduction in the Changjiang sediment flow to the sea has not caused a decline in the ENM. In contrast, the ENM has experienced rapid accretion in the past 40 years, resulting in the strengthening of its functional abilities to protect Shanghai, an unexpected outcome.

  2. The University of Tokyo Atacama Observatory 6.5m Telescope: enclosure design and wind analysis

    NASA Astrophysics Data System (ADS)

    Konishi, Masahiro; Sako, Shigeyuki; Uchida, Takanori; Araya, Ryou; Kim, Koui; Yoshii, Yuzuru; Doi, Mamoru; Kohno, Kotaro; Miyata, Takashi; Motohara, Kentaro; Tanaka, Masuo; Minezaki, Takeo; Morokuma, Tomoki; Tamura, Yoichi; Tanabé, Toshihiko; Kato, Natsuko; Kamizuka, Takafumi; Takahashi, Hidenori; Aoki, Tsutomu; Soyano, Takao; Tarusawa, Ken'ichi

    2016-07-01

    We present results on the computational fluid dynamics (CFD) numerical simulations as well as the wind tunnel experiments for the observation facilities of the University of Tokyo Atacama Observatory 6.5m Telescope being constructed at the summit of Co. Chajnantor in northern Chile. Main purpose of this study starting with the baseline design reported in 2014 is to analyze topographic effect on the wind behavior, and to evaluate the wind pressure, the air turbulence, and the air change (ventilation) efficiency in the enclosure. The wind velocity is found to be accelerated by a factor of 1.2 to reach the summit (78 m sec-1 expected at a maximum), and the resulting wind pressure (3,750 N m-2) is used for the framework design of the facilities. The CFD data reveals that the open space below the floor of the facilities works efficiently to drift away the air turbulence near the ground level which could significantly affect the dome seeing. From comparisons of the wind velocity field obtained from the CFD simulation for three configurations of the ventilation windows, we find that the windows at a level of the telescope secondary mirror have less efficiency of the air change than those at lower levels. Considering the construction and maintenance costs, and operation procedures, we finally decide to allocate 13 windows at a level of the observing floor, 12 at a level of the primary mirror, and 2 at the level of the secondary mirror. The opening area by those windows accounts for about 14% of the total interior surface of the enclosure. Typical air change rate of 20-30 per hour is expected at the wind velocity of 1 m sec-1.

  3. 50 CFR 14.131 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... same primary enclosure with an adult marine mammal other than its mother. Socially dependent animals (e.g., siblings, mother, and offspring) transported in the same conveyance shall be allowed visual and...

  4. 50 CFR 14.131 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... same primary enclosure with an adult marine mammal other than its mother. Socially dependent animals (e.g., siblings, mother, and offspring) transported in the same conveyance shall be allowed visual and...

  5. Thermoelectric Control Of Temperatures Of Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Burkett, Cecil G., Jr.; West, James W.; Hutchinson, Mark A.; Lawrence, Robert M.; Crum, James R.

    1995-01-01

    Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

  6. Development, fabrication and evaluation of composite thermal engine insulation

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Foil enclosure configurations of 10 variations were fabricated and evaluated. A discussion of the thermal protection system panel design includes: (1) description of 3DSX/foil concept, (2) design environment, (3) material selection, (4) fabrication enclosure, (5) structural design, (6) thermal sizing, and (7) weight analysis. The structural design study includes foil evaluation, venting pressure loads, thermomechanical behavior, and enclosure venting (burst) pressure tests. Results of experimental demonstrations of performance and reuse capabilities are given for both thermal and acoustic testing.

  7. Cops, cameras, and enclosures : a synthesis of the effectiveness of methods to provide enhanced security for bus operators

    DOT National Transportation Integrated Search

    2001-05-31

    The safety of operators and passengers is a primary concern of transit systems and has become an increasingly important issue to transit bus operators themselves. Many transit agencies have experienced incidents of assaults against their bus operator...

  8. 40 CFR 63.4765 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... determination, substitute TVH for each occurrence of the term volatile organic compounds (VOC) in the methods... organic compound emitting operations inside the building enclosure, other than the coating operation for... the capture efficiency measurement, all organic compound emitting operations inside the building...

  9. 40 CFR 63.4765 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determination, substitute TVH for each occurrence of the term volatile organic compounds (VOC) in the methods... organic compound emitting operations inside the building enclosure, other than the coating operation for... the capture efficiency measurement, all organic compound emitting operations inside the building...

  10. Detail of urinal enclosure on north side of Machine Shop ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of urinal enclosure on north side of Machine Shop (Bldg. 163) - Atchison, Topeka, Santa Fe Railroad, Albuquerque Shops, Machine Shop, 908 Second Street, Southwest, Albuquerque, Bernalillo County, NM

  11. Numerical study of entropy generation due to coupled laminar and turbulent mixed convection and thermal radiation in an enclosure filled with a semitransparent medium.

    PubMed

    Goodarzi, M; Safaei, M R; Oztop, Hakan F; Karimipour, A; Sadeghinezhad, E; Dahari, M; Kazi, S N; Jomhari, N

    2014-01-01

    The effect of radiation on laminar and turbulent mixed convection heat transfer of a semitransparent medium in a square enclosure was studied numerically using the Finite Volume Method. A structured mesh and the SIMPLE algorithm were utilized to model the governing equations. Turbulence and radiation were modeled with the RNG k-ε model and Discrete Ordinates (DO) model, respectively. For Richardson numbers ranging from 0.1 to 10, simulations were performed for Rayleigh numbers in laminar flow (10⁴) and turbulent flow (10⁸). The model predictions were validated against previous numerical studies and good agreement was observed. The simulated results indicate that for laminar and turbulent motion states, computing the radiation heat transfer significantly enhanced the Nusselt number (Nu) as well as the heat transfer coefficient. Higher Richardson numbers did not noticeably affect the average Nusselt number and corresponding heat transfer rate. Besides, as expected, the heat transfer rate for the turbulent flow regime surpassed that in the laminar regime. The simulations additionally demonstrated that for a constant Richardson number, computing the radiation heat transfer majorly affected the heat transfer structure in the enclosure; however, its impact on the fluid flow structure was negligible.

  12. Numerical Study of Entropy Generation due to Coupled Laminar and Turbulent Mixed Convection and Thermal Radiation in an Enclosure Filled with a Semitransparent Medium

    PubMed Central

    Goodarzi, M.; Safaei, M. R.; Oztop, Hakan F.; Karimipour, A.; Sadeghinezhad, E.; Dahari, M.; Kazi, S. N.; Jomhari, N.

    2014-01-01

    The effect of radiation on laminar and turbulent mixed convection heat transfer of a semitransparent medium in a square enclosure was studied numerically using the Finite Volume Method. A structured mesh and the SIMPLE algorithm were utilized to model the governing equations. Turbulence and radiation were modeled with the RNG k-ε model and Discrete Ordinates (DO) model, respectively. For Richardson numbers ranging from 0.1 to 10, simulations were performed for Rayleigh numbers in laminar flow (104) and turbulent flow (108). The model predictions were validated against previous numerical studies and good agreement was observed. The simulated results indicate that for laminar and turbulent motion states, computing the radiation heat transfer significantly enhanced the Nusselt number (Nu) as well as the heat transfer coefficient. Higher Richardson numbers did not noticeably affect the average Nusselt number and corresponding heat transfer rate. Besides, as expected, the heat transfer rate for the turbulent flow regime surpassed that in the laminar regime. The simulations additionally demonstrated that for a constant Richardson number, computing the radiation heat transfer majorly affected the heat transfer structure in the enclosure; however, its impact on the fluid flow structure was negligible. PMID:24778601

  13. Numerical system for monitoring pressurized equipment

    NASA Astrophysics Data System (ADS)

    Dobra, Remus; Pasculescu, Dragos; Boca, Maria Loredana; Moldovan, Lucian

    2016-12-01

    Electrical devices for operation in potentially explosive atmospheres are designed and built in accordance with European standard EN 50015: 1995 ex. the pressurized enclosure "p". The type of protector p, by using a protective gas in the housing is intended to prevent the formation of an explosive atmosphere within it, while maintaining an overpressure to the surrounding atmosphere and, where appropriate, by the use dilution. Research conducted for pressurized encapsulation aimed at developing new procedures for determining the parameters of pressurization to allow safe use of electrical appliances. Pressurization with compensation for losses allegedly maintaining overpressure inside the enclosure when the outlets are closed, is made by feeding protective gas in an amount sufficient to fully compensate for losses from the housing inevitable pressurized and its associated pipework. The conditions and necessary measures that are required for appliances and equipment with potential ignition of explosive atmospheres are detailed in the SR EN 50016/2000. For pressurized encapsulation protection mode, the electric equipment can be maintained safety by the overpressure created inside them and in the supply pipes with air. The paper presents a modern method to determine the parameters of the electric equipment with pressurization enclosures. For controlling of such equipment, a specific algorithm has been developed and laboratory tested.

  14. 40 CFR 63.544 - What are my total enclosure standards?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... where lead bearing material is stored in closed containers or enclosed mechanical conveyors, and areas... area within the building. (d) You must inspect enclosures and facility structures that contain any lead...

  15. Comparison of microhabitats and foraging strategies between the captive-born Zhangxiang and wild giant pandas: implications for future reintroduction.

    PubMed

    Lei, Miaowen; Yuan, Shibin; Yang, Zisong; Hong, Mingsheng; Yang, Xuyu; Gu, Xiaodong; Huang, Feng; Zhang, Zejun

    2015-10-01

    The female giant panda Zhangxiang (pedigree number 826) was born on August 20, 2011 in Wolong Nature Reserve, China. On November 6, 2013, Zhangxiang was transported into the acclimatization enclosure in the Liziping Nature Reserve. Before Zhangxiang left the enclosure into the wild, we conducted the first study to compare microhabitats and foraging strategies between Zhangxiang in the enclosure and giant pandas in the wild. Compared with the latter, microhabitats of Zhangxiang in the enclosure are characteristic of gentler slope, more trees, higher canopy, smaller tree DBH, and lower density of living bamboos. Diet composition and foraging behaviors significantly differed between Zhangxiang and wild giant pandas, perhaps reflecting the combined consequence of environmental conditions (e.g., bamboo species) and individual status (e.g., age, mastication ability, etc.). The difference in microhabitats and foraging strategies between Zhangxiang and wild giant pandas implied that after being released into the natural habitat in the reserve, Zhangxiang will have to adapt to the environmental conditions once again. For future reintroduction, the enclosure can be extended to the Bashania spanostachya forest in the reserve, and captive giant pandas for release can thus normally transit into the wild without human intervention during acclimatization period. For other acclimatization enclosures to be constructed in the future, ecological environment inside, including topography, forests, and bamboos as well, should as possible as can match the habitat that the giant panda to-be-reinforced populations inhabit.

  16. 40 CFR Appendix A to Subpart Dddd... - Alternative Procedure To Determine Capture Efficiency From Enclosures Around Hot Presses in the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of average velocity during the run and using these data, in conjunction with the pre- and post-test..., you may choose to follow the post-test calibration procedures of Method 320 in appendix A to 40 CFR... of hazardous air pollutants during the press process. This test method requires a minimum of three...

  17. 40 CFR 63.4565 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... occurrence of the term volatile organic compounds (VOC) in the methods. (3) Use Equation 1 of this section to... the capture efficiency measurement, all organic compound emitting operations inside the building... organic compound emitting operations inside the building enclosure, other than the coating operation for...

  18. 40 CFR 63.4565 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... occurrence of the term volatile organic compounds (VOC) in the methods. (3) Use Equation 1 of this section to... the capture efficiency measurement, all organic compound emitting operations inside the building... organic compound emitting operations inside the building enclosure, other than the coating operation for...

  19. 40 CFR 63.4565 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the term volatile organic compounds (VOC) in the methods. (3) Use Equation 1 of this section to... the capture efficiency measurement, all organic compound emitting operations inside the building... organic compound emitting operations inside the building enclosure, other than the coating operation for...

  20. 40 CFR 63.4565 - How do I determine the emission capture system efficiency?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the term volatile organic compounds (VOC) in the methods. (3) Use Equation 1 of this section to... the capture efficiency measurement, all organic compound emitting operations inside the building... organic compound emitting operations inside the building enclosure, other than the coating operation for...

  1. 30 CFR 75.700-1 - Approved methods of grounding.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a borehole casing having low resistance to earth; (b) A solid connection to metal waterlines having low resistance to earth; (c) A solid connection to a grounding conductor, other than the neutral... ensures that there is no difference in potential between such metallic enclosures and the earth. ...

  2. 30 CFR 75.700-1 - Approved methods of grounding.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a borehole casing having low resistance to earth; (b) A solid connection to metal waterlines having low resistance to earth; (c) A solid connection to a grounding conductor, other than the neutral... ensures that there is no difference in potential between such metallic enclosures and the earth. ...

  3. Flow Visualization Study of Natural Convection from a Heated Protrusion in a Liquid Filled Rectangular Enclosure.

    DTIC Science & Technology

    1983-12-01

    PROPOSED SOLUTIONS Many papers have been published outlining alternative methods of thermally controlling microelectronic devices. Hannemann [3] describes...Workshop, NSF Grant ENG-7701297, Directions of Heat Transfer in Electronic Equipment, Fy R. C. Chu, 1977. 3. Hannemann , R., "Electronic System Thermal

  4. 40 CFR 53.3 - General requirements for an equivalent method determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... temperature and pressure sensors, outdoor enclosure, electrical power supply, control devices and operator... rate cut-off; operation following power interruptions; effect of variations in power line voltage... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted...

  5. Effects of metsulfuron methyl and cypermethrin exposure on freshwater model ecosystems.

    PubMed

    Wendt-Rasch, L; Pirzadeh, P; Woin, P

    2003-05-08

    The aim of this study was to investigate the short-term (2 weeks) effects of the herbicide metsulfuron methyl alone and in combination with the insecticide cypermethrin in freshwater enclosures (80 l). We used a factorial design with four levels of herbicide (0, 1, 5, 20 microg/l) and two levels of insecticide (0 and 0.05 microg/l). The root growth of the macrophyte species Elodea canadensis and Myriophyllum spicatum decreased following exposure to the lowest concentration of metsulfuron methyl tested. Metsulfuron methyl exposure resulted in a decreased pH in the aquatic enclosure at the lowest concentration tested, which is most likely a further indication of decreased macrophyte primary production. The biomass of periphytic algae growing on the leaves of M. spicatum increased in the enclosures exposed to metsulfuron methyl. The species composition of the periphytic algae differed significantly from the controls in the enclosures exposed to 20 microg/l of the herbicide. The increased biomass of periphytic algae on the leaves of the macrophytes is probably an indirect effect of the herbicide exposure. The exposure to metsulfuron methyl possibly induced a leakage of nutrients from the macrophyte leaves, which promoted an increased algal growth. The exposure to metsulfuron methyl did not alter the biomass or the species composition of the phytoplankton community. The zooplankton communities in the enclosures were dominated by rotifers, which were not affected by the exposure to cypermethrin. However, a cypermethrin exposure of 0.05 microg/l initially decreased the abundance of copepod nauplii. Ten days after exposure, the abundance of nauplii was significantly higher in the insecticide-exposed enclosures compared with the non-exposed enclosures. This might be an indication of a sub-lethal stress response, which either increased the number of offspring produced or induced an increased hatching of copepod resting stages. No combined effects of the herbicide and insecticide exposure, either direct or indirect, were observed in the enclosure study. Significant effects on the macrophytes were observed following exposure to 1 microg metsulfuron methyl per litre in the enclosure study. Furthermore, a single species laboratory assay indicated that the shoot elongation of E. canadensis decreased following exposure to >or=0.1 microg metsulfuron methyl per litre. These concentrations are well within the range of expected environmental concentrations, thus this study shows that aquatic ecosystems, in particular those which are macrophyte-dominated, may be affected by metsulfuron methyl at concentrations that may well occur in water bodies adjacent to agricultural land.

  6. ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stearman, D. M.

    2015-03-30

    Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and commandmore » line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.« less

  7. Performance of masonry enclosure walls: lessons learned from recent earthquakes

    NASA Astrophysics Data System (ADS)

    Vicente, Romeu Silva; Rodrigues, Hugo; Varum, Humberto; Costa, Aníbal; Mendes da Silva, José António Raimundo

    2012-03-01

    This paper discusses the issue of performance requirements and construction criteria for masonry enclosure and infill walls. Vertical building enclosures in European countries are very often constituted by non-load-bearing masonry walls, using horizontally perforated clay bricks. These walls are generally supported and confined by a reinforced concrete frame structure of columns and beams/slabs. Since these walls are commonly considered to be nonstructural elements and their influence on the structural response is ignored, their consideration in the design of structures as well as their connection to the adjacent structural elements is frequently negligent or insufficiently detailed. As a consequence, nonstructural elements, as for wall enclosures, are relatively sensitive to drift and acceleration demands when buildings are subjected to seismic actions. Many international standards and technical documents stress the need for design acceptability criteria for nonstructural elements, however they do not specifically indicate how to prevent collapse and severe cracking, and how to enhance the overall stability in the case of moderate to high seismic loading. Furthermore, a review of appropriate measures to improve enclosure wall performance and both in-plane and out-of-plane integrity under seismic actions is addressed.

  8. 41. AUXILIARY CHAMBER, CONCRETE ENCLOSURE CHAMBER AIR LOCK (EXTERIOR), LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. AUXILIARY CHAMBER, CONCRETE ENCLOSURE CHAMBER AIR LOCK (EXTERIOR), LOOKING NORTHEAST FROM SOUTHWEST CORNER (LOCATION AAA) - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA

  9. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  10. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  11. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  12. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  13. 30 CFR 18.98 - Enclosures, joints, and fastenings; pressure testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... consistent with unyielding components during a pressure-time history as derived from a series of oscillograms...; pressure testing. (a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure...

  14. A four-panel enclosure protects from explosion

    NASA Technical Reports Server (NTRS)

    King, P. V.

    1972-01-01

    Development of multi-layered baffle as enclosure to protect personnel from effects of explosion during production of ammunition is discussed. Advantages of new system over previous systems are described. Illustration of typical panel structure is provided.

  15. 46 CFR 72.05-15 - Ceilings, linings, trim, and decorations in accommodation spaces and safety areas.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... used in corridors or stairway enclosures. (d) Combustible veneers, trim, decorations, etc., shall not... subchapter Q (Specifications) of this chapter. This includes corridors, stairway enclosures, and hidden...

  16. 44. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION CCC), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION CCC), LOOKING NORTHEAST SHOWING DRAIN PIPE FROM SUMP - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA

  17. Detection of free liquid in containers of solidified radioactive waste

    DOEpatents

    Greenhalgh, W.O.

    Nondestructive detection of the presence of free liquid within a sealed enclosure containing solidified waste is accomplished by measuring the levels of waste at two diametrically opposite locations while slowly tilting the enclosure toward one of said locations. When the measured level remains constant at the other location, the measured level at said one location is noted and any measured difference of levels indicates the presence of liquid on the surface of the solifified waste. The absence of liquid in the enclosure is verified when the measured levels at both locations are equal.

  18. SPRUCE Epiphytic Lichen Annual Biomass Growth in Experimental Plots, 2013-2016.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, R.J.; Nelson, P.R.; Jovan, S.

    This data set provides annual biomass growth rates of epiphytic lichen transplants in the SPRUCE experimental plots at the S1 Bog of the Marcell Experimental Forest. Epiphytic lichens (Evernia mesomorpha, a boreal forest indicator species) were collected at S1 Bog outside the experimental enclosures and mounted on Picea mariana branches inside the 10 experimental enclosures and the 2 ambient plots without enclosures using transplant techniques. Lichen transplants were weighed annually, in August of 2013-2016, to measure biomass growth rates as a function of experimental temperature and CO2 treatments.

  19. EXPERIMENTAL ANIMAL WATERING DEVICE

    DOEpatents

    Finkel, M.P.

    1964-04-01

    A device for watering experimental animals confined in a battery of individual plastic enclosures is described. It consists of a rectangular plastic enclosure having a plurality of fluid-tight compartments, each with a drinking hole near the bottom and a filling hole on the top. The enclosure is immersed in water until filled, its drinking holes sealed with a strip of tape, and it is then placed in the battery. The tape sealing prevents the flow of water from the device, but permits animals to drink by licking the drinking holes. (AEC)

  20. Design and construction of a 76m long-travel laser enclosure for a space occulter testbed

    NASA Astrophysics Data System (ADS)

    Galvin, Michael; Kim, Yunjong; Kasdin, N. Jeremy; Sirbu, Dan; Vanderbei, Robert; Echeverri, Dan; Sagolla, Giuseppe; Rousing, Andreas; Balasubramanian, Kunjithapatham; Ryan, Daniel; Shaklan, Stuart; Lisman, Doug

    2016-07-01

    Princeton University is upgrading our space occulter testbed. In particular, we are lengthening it to 76m to achieve flightlike Fresnel numbers. This much longer testbed required an all-new enclosure design. In this design, we prioritized modularity and the use of commercial off-the-shelf (COTS) and semi-COTS components. Several of the technical challenges encountered included an unexpected slow beam drift and black paint selection. Herein we describe the design and construction of this long-travel laser enclosure.

  1. Multispectral imaging system for contaminant detection

    NASA Technical Reports Server (NTRS)

    Poole, Gavin H. (Inventor)

    2003-01-01

    An automated inspection system for detecting digestive contaminants on food items as they are being processed for consumption includes a conveyor for transporting the food items, a light sealed enclosure which surrounds a portion of the conveyor, with a light source and a multispectral or hyperspectral digital imaging camera disposed within the enclosure. Operation of the conveyor, light source and camera are controlled by a central computer unit. Light reflected by the food items within the enclosure is detected in predetermined wavelength bands, and detected intensity values are analyzed to detect the presence of digestive contamination.

  2. Influence of container shape on scaling of turbulent fluctuations in convection

    NASA Astrophysics Data System (ADS)

    Foroozani, Najmeh; Niemela, Joseph J.; Armenio, Vincenzo; Sreenivasan, Katepalli R.

    2014-11-01

    We perform large-eddy simulations of turbulent convection in a cubic enclosure for Rayleigh numbers 1 ×106 <= Ra <= 1 ×1010 and molecular Prandtl number, Pr = 0 . 7 . The simulations were carried out using a second-order-accurate finite-difference method in which subgrid-scale fluxes of momentum and heat were parametrized using a Lagrangian dynamic Smagorinsky model. The scalings of root-mean-square fluctuations of density and velocity in the cell center with Ra differ significantly from those in cylindrical containers, and are in agreement with laboratory observations by, also using a cell with square cross-section. We find that the time-averaged spatial distributions of the local heat flux and temperature fluctuations are inhomogeneous in the horizontal plane, associated with the forced orientation of the mean wind along either one or the other diagonal. Larger values of the steady-state density (temperature) gradients occur at the mid-plane corners of the diagonal opposite to that of the mean wind, due to the presence of strong counter-rotating circulations.

  3. New Definitions of Electromagnetic Screening of Cases in Front of Radiates Interferences

    NASA Astrophysics Data System (ADS)

    Garcia Perez, Luis Gines

    Electromagnetic shielding enclosures are simulated in this PhD thesis. Metallic enclosures with a frontal aperture have been implemented and shielding effectiveness has been calculated in frequency and time domains. The CST Microwave Studio application has been used, and necessary electromagnetic shielding measurements have been implemented in order to confirm the simulated results. An anechoic chamber and the network vector analyser ZVA 67 R&S have been employed. There were different set-ups that consist on two shielding enclosures with different apertures on their frontal walls, as well as an electric and a magnetic probes, and an external log-periodic antenna. The electromagnetic field shielding of enclosures against radiated interferences, and its study in the frequency and time domains requires to determine specific parameters for the measurement of the shielding effectiveness (SE). With this target recently it has been essayed indicators based on the peak reduction of electric and magnetic fields and the energy density in the time domain. Although many papers have been published with numeric simulations, rarely real measures in laboratory have been published. In the first part of this study, some important theoretical concepts have been explained, as the high intensity penetration of radiated fields in enclosures with apertures, several ways to define the shielding effectiveness, analytic formulations and different parameters among other concepts, in the frequency and time domains. Then, the system is defined, as from the implementations for simulations and calculations in CST Microwave Studio point of view, as from the set-ups implemented in laboratory point of view. In this section the features and utilization of the network vector analyser ZVA 67 R&S;, anechoic chamber design and dimensions, log-periodic antenna features, and all the different probes, enclosures and apertures employed have been detailed. After de system definition simulated and measured results have been obtained for some definitions and used SE indicators for incident plane wave against enclosures in a specific bandwidth. The plane wave has been treated as a reference interference to compare to other electromagnetic interference cases. It has been verified that the laboratory measurements and the simulations are in good agreement. The effects of the electric (dipole) and magnetic (loop) probes presences have been analysed too, as they can modified the results. In this study new SE definitions (new indicators) have been evaluated too, and they have been compared with the classical time-domain SE definitions. These new indicators have been studied as function of several parameters that can be modified in the enclosures as the aperture dimensions or the enclosure dimensions. Finally, in order to get more generic solutions that can be useful to later SE studies, the new SE results have been analysed and interpreted for an aperture size scanning that provide an unique value for the more critical SE indicator and for an specific bandwidth allowing direct SE comparisons with other enclosures.

  4. Evolution of a chemically reacting plume in a ventilated room

    NASA Astrophysics Data System (ADS)

    Conroy, D. T.; Smith, Stefan G. Llewellyn; Caulfield, C. P.

    2005-08-01

    The dynamics of a second-order chemical reaction in an enclosed space driven by the mixing produced by a turbulent buoyant plume are studied theoretically, numerically and experimentally. An isolated turbulent buoyant plume source is located in an enclosure with a single external opening. Both the source and the opening are located at the bottom of the enclosure. The enclosure is filled with a fluid of a given density with a fixed initial concentration of a chemical. The source supplies a constant volume flux of fluid of different density containing a different chemical of known and constant concentration. These two chemicals undergo a second-order non-reversible reaction, leading to the creation of a third product chemical. For simplicity, we restrict attention to the situation where the reaction process does not affect the density of the fluids involved. Because of the natural constraint of volume conservation, fluid from the enclosure is continually vented. We study the evolution of the various chemical species as they are advected by the developing ventilated filling box process within the room that is driven by the plume dynamics. In particular, we study both the mean and vertical distributions of the chemical species as a function of time within the room. We compare the results of analogue laboratory experiments with theoretical predictions derived from reduced numerical models, and find excellent agreement. Important parameters for the behaviour of the system are associated with the source volume flux and specific momentum flux relative to the source specific buoyancy flux, the ratio of the initial concentrations of the reacting chemical input in the plume and the reacting chemical in the enclosed space, the reaction rate of the chemicals and the aspect ratio of the room. Although the behaviour of the system depends on all these parameters in a non-trivial way, in general the concentration within the room of the chemical input at the isolated source passes through three distinct phases. Initially, as the source fluid flows into the room, the mean concentration of the input chemical increases due to the inflow, with some loss due to the reaction with the chemical initially within the room. After a finite time, the layer of fluid contaminated by the inflow reaches the opening to the exterior at the base of the room. During an ensuing intermediate phase, the rate of increase in the concentration of the input chemical then drops non-trivially, due to the extra sink for the input chemical of the outflow through the opening. During this intermediate stage, the concentration of the input chemical continues to rise, but at a rate that is reduced due to the reaction with the fluid in the room. Ultimately, all the fluid (and hence the chemical) that was originally within the room is lost, both through reaction and outflow through the opening, and the room approaches its final steady state, being filled completely with source fluid.

  5. Recovering and Mining Asteroids with a Gas-Sealed Enclosure

    NASA Astrophysics Data System (ADS)

    Jenniskens, P.; Damer, B.; Norkus, R.; Pilotz, S.; Grigsby, B.; Adams, C.; Blair, B. R.

    2015-01-01

    The internal structure of weakly consolidated rubble piles and primitive asteroids can be studied closer to home, and such asteroids can be mined, if it is possible to create a gas-sealed enclosure around the asteroid.

  6. Space use as an indicator of enclosure appropriateness in African wild dogs (Lycaon pictus).

    PubMed

    Hunter, Sally C; Gusset, Markus; Miller, Lance J; Somers, Michael J

    2014-01-01

    A clear understanding of space use is required to more fully understand biological requirements of nonhuman animals in zoos, aid the design of exhibits, and maximize the animals' welfare. This study used electivity indexes to assess space use of two packs of African wild dogs (Lycaon pictus) and the appropriateness of two naturalistic, outdoor enclosures at the San Diego Zoo and Bronx Zoo. The results identified enclosure features that were both underutilized and overutilized. They suggest that replacing underutilized areas with features similar to areas that were overutilized may provide more preferred opportunities for the animals. Assessing space use of animals in human care may serve as an indicator of enclosure appropriateness and could have welfare implications. By looking at the possible reasons for area preferences, animal managers can get an idea of where improvements could be made. Designing future exhibits accordingly thus can provide possible welfare benefits for the animals concerned.

  7. Sound reduction by metamaterial-based acoustic enclosure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, Shanshan; Li, Pei; Zhou, Xiaoming

    In many practical systems, acoustic radiation control on noise sources contained within a finite volume by an acoustic enclosure is of great importance, but difficult to be accomplished at low frequencies due to the enhanced acoustic-structure interaction. In this work, we propose to use acoustic metamaterials as the enclosure to efficiently reduce sound radiation at their negative-mass frequencies. Based on a circularly-shaped metamaterial model, sound radiation properties by either central or eccentric sources are analyzed by numerical simulations for structured metamaterials. The parametric analyses demonstrate that the barrier thickness, the cavity size, the source type, and the eccentricity of themore » source have a profound effect on the sound reduction. It is found that increasing the thickness of the metamaterial barrier is an efficient approach to achieve large sound reduction over the negative-mass frequencies. These results are helpful in designing highly efficient acoustic enclosures for blockage of sound in low frequencies.« less

  8. Isoprene emission rates and fluxes measured above a Mediterranean oak ( Quercus pubescens) forest

    NASA Astrophysics Data System (ADS)

    Simon, V.; Dumergues, L.; Bouchou, P.; Torres, L.; Lopez, A.

    2005-03-01

    The present work, carried out as part of the European fiEld experimentS to COnstrain Models of atmospheric Pollution and Transport of Emissions project (ESCOMPTE), brings a new contribution to the inventory of the main natural hydrocarbons sources that are liable to participate in the production of ozone. The measurement campaign was conducted in Montmeyan, a site close to Marseilles (France), with the aim of quantifying the terpenic emission pattern and the behaviour of Quercus pubescens, an important Mediterranean tree species. Biogenic emissions by Q. pubescens were determined by the enclosure of an intact branch of this tree in a Teflon cuvette. The total monoterpenic emission rates thus recorded were found to reach maximum values ranged between 40 and 350 μg g Dry Weight-1 h -1. Emissions were correlated strongly with leaf temperature and Photosynthetic Active Radiation (PAR). The fluxes were also determined by extrapolating the results of the enclosure method and by using aerodynamic gradient method. They reach around 73 mg m -2 h -1 with the first method and 55 mg m -2 h -1 with the second one. The obtained values fit with a maximal ratio of 2.

  9. Lead toxicity: consequences and interventions in an intensively managed (Gyps coprotheres) vulture colony.

    PubMed

    Naidoo, Vinny; Wolter, Kerri; Espie, Ian; Kotze, Antoinette

    2012-09-01

    The National Zoological Gardens of South Africa (NZG) is involved in the ex situ conservation of Gyps coprotheres, the Cape Griffon vulture (CGV) and houses 24 birds in a 100-yr-old aviary. Following the death of one vulture with high liver lead concentrations, an investigation was launched to ascertain the source(s) and consequences of lead toxicity in this breeding colony. Whole blood from 24 CGV, paint from the enclosure, water, and soil sampled at various locations within the enclosure were evaluated for their lead concentration, and data were gathered from NZG's medical records. The lead concentration in the paint, water, and enclosure soil was 5,100 microg/g, 0.5 microg/dl, and 72.48 +/- 21.83 microg/g, respectively. The whole-blood lead concentrations were 56.58 +/- 11 microg/dl. The breeding history of six pairs within the contaminated enclosure since 2002 showed 45 eggs laid, of which 44% were infertile and 24% successfully reared. The medical records revealed evidence of osteodystrophy despite adequate nutrition. As intervention measures, six birds were treated with Ca2+EDTA and the topsoil inside the enclosure was replaced. As a result, the lead concentration in the enclosure soil dropped to 14.74 +/- 14.39 microg/g, and the whole-blood lead concentrations declined to 42.75 +/- 11.64 microg/dl. It was concluded that lead concentrations in whole blood in excess of 100 microg/dl leads to clinical signs of lead toxicity in the CGV. Lower levels appear to interfere mainly with reproductive potential.

  10. Potential arsenic exposures in 25 species of zoo animals living in CCA-wood enclosures.

    PubMed

    Gress, J; da Silva, E B; de Oliveira, L M; Zhao, Di; Anderson, G; Heard, D; Stuchal, L D; Ma, L Q

    2016-05-01

    Animal enclosures are often constructed from wood treated with the pesticide chromated copper arsenate (CCA), which leaches arsenic (As) into adjacent soil during normal weathering. This study evaluated potential pathways of As exposure in 25 species of zoo animals living in CCA-wood enclosures. We analyzed As speciation in complete animal foods, dislodgeable As from CCA-wood, and As levels in enclosure soils, as well as As levels in biomarkers of 9 species of crocodilians (eggs), 4 species of birds (feathers), 1 primate species (hair), and 1 porcupine species (quills). Elevated soil As in samples from 17 enclosures was observed at 1.0-110mg/kg, and enclosures housing threatened and endangered species had As levels higher than USEPA's risk-based Eco-SSL for birds and mammals of 43 and 46mg/kg. Wipe samples of CCA-wood on which primates sit had dislodgeable As residues of 4.6-111μg/100cm(2), typical of unsealed CCA-wood. Inorganic As doses from animal foods were estimated at 0.22-7.8μg/kg bw/d. Some As levels in bird feathers and crocodilian eggs were higher than prior studies on wild species. However, hair from marmosets had 6.37mg/kg As, 30-fold greater than the reference value, possibly due to their inability to methylate inorganic As. Our data suggested that elevated As in soils and dislodgeable As from CCA-wood could be important sources of As exposure for zoo animals. Published by Elsevier B.V.

  11. Region 9: California Imperial County Adequate Letter Enclosure (5/20/2008)

    EPA Pesticide Factsheets

    This document is the enclosure to the April 16, 2008, letter from EPA provides an adequacy finding for transportation conformity purposes the motor vehicle emissions budgets in the Imperial County 8-hour Ozone Early Progress Plan.

  12. 32 CFR 283.5 - Responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to enclosure 2 of DoD Directive 5118.3. 1 1 Available at http://www.dtic.mil/whs/directives/. (2) If... application pursuant to enclosure 2 of DoD Directive 1342.6. 2 2 Available at http://www.dtic.mil/whs...

  13. 32 CFR 283.5 - Responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to enclosure 2 of DoD Directive 5118.3. 1 1 Available at http://www.dtic.mil/whs/directives/. (2) If... application pursuant to enclosure 2 of DoD Directive 1342.6. 2 2 Available at http://www.dtic.mil/whs...

  14. 32 CFR 283.5 - Responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to enclosure 2 of DoD Directive 5118.3. 1 1 Available at http://www.dtic.mil/whs/directives/. (2) If... application pursuant to enclosure 2 of DoD Directive 1342.6. 2 2 Available at http://www.dtic.mil/whs...

  15. 32 CFR 283.5 - Responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to enclosure 2 of DoD Directive 5118.3. 1 1 Available at http://www.dtic.mil/whs/directives/. (2) If... application pursuant to enclosure 2 of DoD Directive 1342.6. 2 2 Available at http://www.dtic.mil/whs...

  16. 32 CFR 283.5 - Responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to enclosure 2 of DoD Directive 5118.3. 1 1 Available at http://www.dtic.mil/whs/directives/. (2) If... application pursuant to enclosure 2 of DoD Directive 1342.6. 2 2 Available at http://www.dtic.mil/whs...

  17. NorthEast view; Interior view of stair enclosure and stair from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    North-East view; Interior view of stair enclosure and stair from platform to main passenger terminal - North Philadelphia Station, 2900 North Broad Street, on northwest corner of Broad Street & Glenwood Avenue, Philadelphia, Philadelphia County, PA

  18. Testing the effect of increased temperature and river water input on benthic and pelagic metabolism using a large scale experimental pond ecosystem

    NASA Astrophysics Data System (ADS)

    Rodriguez, Patricia; Geibrink, Erik; Vasconcelos, Francisco; Hedström, Per; Byström, Pär; Karlsson, Jan

    2013-04-01

    We performed a large scale experimental study to test the effect of increased temperatures and concentration of allochthonous dissolved organic carbon (DOC) on benthic and pelagic primary production and respiration. The experiment was carried out during one ice-free season (May-October 2012) in a clear-water pond ecosystem divided into 16 enclosures (each 120 m3 and 1.6 m deep) including natural benthic and pelagic habitats and fish as top consumers (40 adult three-spine sticklebacks were introduced at the beginning of the experiment). Treatments included input of brown river water (23 mg/L in DOC) and heating (3° C above ambient temperature) in a factorial design: 4 enclosures were kept as controls (clear-cold), 4 enclosures were heated (clear-hot), 4 received river water (dark-cold) and 4 were both heated and received river water (dark-hot). Physical and chemical variables were monitored weekly meanwhile benthic, pelagic and ecosystems metabolism were estimated from free-water oxygen data and incubation studies. The 3° C difference in temperature between hot and cold enclosures was consistent during the study and DOC concentrations averaged 4 and 8 mg/L in clear water and dark enclosures, respectively; without any interaction effect between temperature and DOC concentration. Vertical light attenuation coefficient (Kd) showed significant differences between treatments with (0.62±0.40 m-1) and without river water (0.24±0.13 m-1). Total nitrogen concentrations ranged between 187 and 300 μg/L, with higher values in the dark-cold enclosures. The same pattern of higher values in dark-cold enclosures was found in phytoplankton chlorophyll a and primary production. Preliminary results show that gross benthic primary production (higher in clear-cold enclosures) largely exceeded phytoplankton production at the beginning of the experiment. Due to high respiration compared to gross primary production the net ecosystem production was in general negative in the pelagic habitat and did not show any effect of temperature or river water treatment. Our results suggest that input of river water may affect relatively shallow lake ecosystems differently compared to what is generally assumed based on studies of deeper systems.

  19. 30 CFR 75.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... receiving power from ungrounded alternating current power systems. 75.701-1 Section 75.701-1 Mineral... receiving power from ungrounded alternating current power systems. For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power...

  20. 30 CFR 75.701-1 - Approved methods of grounding of equipment receiving power from ungrounded alternating current...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... receiving power from ungrounded alternating current power systems. 75.701-1 Section 75.701-1 Mineral... receiving power from ungrounded alternating current power systems. For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power...

  1. 40 CFR Table 8 to Subpart Wwww of... - Initial Compliance With Organic HAP Emissions Limits

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... open molding and centrifugal casting operations a. an organic HAP emissions limit shown in Tables 3 or... method meet the appropriate organic HAP contents. 2. open molding centrifugal casting, continuous... reduction is being claimed, are using direct die injection, and/or wet-area enclosures that meet the...

  2. 40 CFR Table 8 to Subpart Wwww of... - Initial Compliance With Organic HAP Emissions Limits

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... open molding and centrifugal casting operations a. an organic HAP emissions limit shown in Tables 3 or... method meet the appropriate organic HAP contents. 2. open molding centrifugal casting, continuous... reduction is being claimed, are using direct die injection, and/or wet-area enclosures that meet the...

  3. 40 CFR Table 8 to Subpart Wwww of... - Initial Compliance With Organic HAP Emissions Limits

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... open molding and centrifugal casting operations a. an organic HAP emissions limit shown in Tables 3 or... method meet the appropriate organic HAP contents. 2. open molding centrifugal casting, continuous... reduction is being claimed, are using direct die injection, and/or wet-area enclosures that meet the...

  4. 9 CFR 3.11 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., Treatment, and Transportation of Dogs and Cats 1 Animal Health and Husbandry Standards § 3.11 Cleaning... prevent an excessive accumulation of feces and food waste, to prevent soiling of the dogs or cats... water is used to clean the primary enclosure, whether by hosing, flushing, or other methods, dogs and...

  5. 24 CFR 3280.808 - Wiring methods and materials.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... frames where the cable or armor would be less than 11/2 inches from the inside or outside surface of the studs when the wall covering materials are in contact with the studs. Steel plates on each side of the... used when closely routed against frames, and equipment enclosures. (l) The cables or conductors shall...

  6. 9 CFR 3.11 - Cleaning, sanitization, housekeeping, and pest control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., Treatment, and Transportation of Dogs and Cats 1 Animal Health and Husbandry Standards § 3.11 Cleaning... prevent an excessive accumulation of feces and food waste, to prevent soiling of the dogs or cats... water is used to clean the primary enclosure, whether by hosing, flushing, or other methods, dogs and...

  7. 45. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION DDD), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION DDD), VIEW LOOKING EAST. LEAD ENCLOSED PIPING IS DRAIN FROM BOILER CHAMBER No. 1 - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA

  8. 50 CFR 14.161 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Wild Mammals and Birds to the United States Specifications for Other Terrestrial Mammals § 14.161... primary enclosure shall provide adequate space for the animal to stand upright in a normal posture with... lie in a full prone position. Specifications for Birds ...

  9. Plasma digital density determining device

    DOEpatents

    Sprott, Julien C.; Lovell, Thomas W.; Holly, Donald J.

    1976-01-01

    The density of a decaying plasma in an electrically conducting enclosure is determined by applying an excitation to the cavity formed by the enclosure and counting digitally the number of resonant frequencies traversed by the combination of the cavity and the decaying plasma.

  10. 24. LAUNCH CONTROL CAPSULE. ENTRANCE TO ACOUSTICAL ENCLOSURE. SHOCK ISOLATOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. LAUNCH CONTROL CAPSULE. ENTRANCE TO ACOUSTICAL ENCLOSURE. SHOCK ISOLATOR AT FAR LEFT. VIEW TO NORTH. - Minuteman III ICBM Launch Control Facility November-1, 1.5 miles North of New Raymer & State Highway 14, New Raymer, Weld County, CO

  11. Wind fence enclosures for infrasonic wind noise reduction.

    PubMed

    Abbott, JohnPaul; Raspet, Richard; Webster, Jeremy

    2015-03-01

    A large porous wind fence enclosure has been built and tested to optimize wind noise reduction at infrasonic frequencies between 0.01 and 10 Hz to develop a technology that is simple and cost effective and improves upon the limitations of spatial filter arrays for detecting nuclear explosions, wind turbine infrasound, and other sources of infrasound. Wind noise is reduced by minimizing the sum of the wind noise generated by the turbulence and velocity gradients inside the fence and by the area-averaging the decorrelated pressure fluctuations generated at the surface of the fence. The effects of varying the enclosure porosity, top condition, bottom gap, height, and diameter and adding a secondary windscreen were investigated. The wind fence enclosure achieved best reductions when the surface porosity was between 40% and 55% and was supplemented by a secondary windscreen. The most effective wind fence enclosure tested in this study achieved wind noise reductions of 20-27 dB over the 2-4 Hz frequency band, a minimum of 5 dB noise reduction for frequencies from 0.1 to 20 Hz, constant 3-6 dB noise reduction for frequencies with turbulence wavelengths larger than the fence, and sufficient wind noise reduction at high wind speeds (3-6 m/s) to detect microbaroms.

  12. Role of Personality in Behavioral Responses to New Environments in Captive Asiatic Lions (Panthera leo persica)

    PubMed Central

    Quintavalle Pastorino, Giovanni; Viau, Anna; Curone, Giulio; Pearce-Kelly, Paul; Faustini, Massimo; Vigo, Daniele; Preziosi, Richard

    2017-01-01

    Studying personality in captive animals may enable the development of individual-based management decisions, which may improve animal welfare. Asiatic lions at London Zoo represent an opportunity to research an understudied species' response to new environments since they have experienced social and physical changes, such as new enclosures and increased social interaction with humans. This project aimed to investigate the role of personality in behavioral responses to these changes. Lion personality questionnaires completed by keepers and direct focal animal observations were used to create personality profiles. Time budgets and enclosure use were determined and compared between control nights and event nights and between the lions' previous enclosure and their new one. The results showed a lack of difference in time budget and enclosure use between control and social event nights, and the spread of participation index values revealed that the lions use their enclosures unevenly. Personality profiles identified various traits that could assist with individual-based management decisions. As the first study to assess Asiatic lions personality, this research contributes to the creation of consistent and valid methodology for evaluating captive animal personality that may improve husbandry and welfare protocols for individual lions, leading to the improved health and success of the species. PMID:28638674

  13. Environmental structure and energetic consequences in groups of young mice.

    PubMed

    Shelton, Delia S; Meyer, Paul M; Ocasio, Karen M

    2017-08-01

    Microenvironments can have considerable physiological consequences for the inhabitants by influencing the movements of individual members. The microenvironment can permit more diverse aggregation patterns or restrict movements to certain dimensions. Here, we tested whether aspects of the microenvironment that influenced aggregation patterns also influenced the energetics of groups of young animals. We tested the effects of enclosure configuration on the group temperature and respiration of infant mice (Mus musculus). We monitored the huddle temperature and respiration of groups in flat, concave and conical enclosures, which varied in shape and available space, and consequently the types of movements they permitted. We found that the amount of available space (or density) had a stronger effect on the group temperature than did the shape of the enclosure or types of permissible movements. We found no evidence that density or shape of the arena strongly affected the respiration rate of the group, with groups showing similar levels of oxygen consumption in all treatments. The lower density enclosures conveyed a considerable metabolic savings to groups in comparison to those tested in a higher density enclosure. These findings show density can have a large effect on the energetics of young mice, and provide insights on how simple features of the environment will influence physiology in a changing world. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The potential for use of steam at atmospheric pressure to decontaminate or sterilize parenteral filling lines incorporating barrier isolation technology.

    PubMed

    Lysfjord, J P; Haas, P J; Melgaard, H L; Pflug, I J

    1995-01-01

    Barrier isolators that enclose aseptic filling equipment are being proposed as a means of: (1) assisting in achieving a 10(-6) sterility assurance level (SAL) in the filling area and (2) minimizing the clean environment required in the manufacturing area. The need for operator and maintenance access to the interior of the barrier isolators presents difficulties in achieving the above goals. Several methods are available for reducing the microbial level inside the isolation barrier. If the objective is the decontamination of all surfaces inside the enclosure, saturated steam at atmospheric pressure can be used. If the objective is to sterilize the inside of the enclosure, saturated steam at atmospheric pressure with added H2O2 can be used. Test data and practical interface considerations relative to various methodologies will be reviewed.

  15. First Interlaboratory Comparison on Calibration of Temperature-Controlled Enclosures in Turkey

    NASA Astrophysics Data System (ADS)

    Uytun, A.; Kalemci, M.

    2017-11-01

    The number of accredited laboratories in the field of calibration of temperature-controlled enclosures has been increasing in Turkey. One of the main criteria demonstrating the competence of a calibration laboratory is successful participation in interlaboratory comparisons. Therefore, TUBITAK UME Temperature Laboratory organized the first interlaboratory comparison on "Calibration of Temperature-Controlled Enclosures" in Turkey as a pilot laboratory between January and November, 2013. Forty accredited laboratories which provide routine calibration services to the industry in this field participated in the comparison. The standards used during the comparison was a climatic chamber for the measurements at -40 {°}C, -20 {°}C, 40 {°}C and 100 {°}C and an oven for the measurements at 200 {°}C. The protocol of the comparison was prepared considering guide EURAMET cg-20 and BS EN/IEC standards 600068-3-5 and 600068-3-11. During the comparison measurements, each participant had the liberty to choose the most convenient calibration points in terms of their accreditation scope among the values mentioned above and carried out on-site measurements at UME. The details and the results of this comparison are given in the paper. Determination of the statistical consistency of the results with the uncertainties given by the participants can be assessed by the method of En value assessment for each laboratory. En values for all measurement results based on the results of pilot and participating laboratories were calculated.

  16. 9 CFR 3.80 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... injuring themselves; and (xi) Provide sufficient space for the nonhuman primates to make normal postural... maintained so as to provide sufficient space to allow each nonhuman primate to make normal postural... postural adjustments and movements within the primary enclosure. Different species of prosimians vary in...

  17. MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid

    NASA Astrophysics Data System (ADS)

    Armaghani, T.; Esmaeili, H.; Mohammadpoor, Y. A.; Pop, I.

    2018-01-01

    In this paper, the steady mixed convection flow and heat transfer of water-copper oxide nanofluid in an open C-shaped enclosure is investigated numerically. The enclosure is under constant magnetic field. Effects of Richardson number, magnetic and nanofluid volume fraction parameters are studied and discussed. The nanofluid with a cold temperature of T C and a velocity of u c enters the enclosure from the top right corner and exits from the bottom right corner. The vertical wall of the left side is subjected to a hot and constant temperature T h . Also, other walls are insulated. It is found that the heat transfer is increased via increasing the Hartmann and Reynolds numbers. For low Reynolds numbers, the enhances of the Hartman number leads to a slightly increases of the average Nusselt number, but for high Reynolds numbers, the average Nusselt number gets an ascending trend and the increase in the Hartmann number shows its effect more pronounced. Also, with increase in Ri, the effect of nanofluid on the heat transfer increases. Due to practical impotence, the study of mixed convection heat transfer in enclosures and various shaped of cavities has attracted remarkable attentions in the past few decades. Significant applications of the mixed convection flow can be found in atmospheric flows, solar energy storage, heat exchangers, lubrication technology, drying technologies, cooling of the electronic devices, etc. The present results are original and new for the problem of MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid. Comparison of the obtained results with those from the open literature (Mahmoodi et al. [24]) is acceptable.

  18. MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid

    NASA Astrophysics Data System (ADS)

    Armaghani, T.; Esmaeili, H.; Mohammadpoor, Y. A.; Pop, I.

    2018-06-01

    In this paper, the steady mixed convection flow and heat transfer of water-copper oxide nanofluid in an open C-shaped enclosure is investigated numerically. The enclosure is under constant magnetic field. Effects of Richardson number, magnetic and nanofluid volume fraction parameters are studied and discussed. The nanofluid with a cold temperature of T C and a velocity of u c enters the enclosure from the top right corner and exits from the bottom right corner. The vertical wall of the left side is subjected to a hot and constant temperature T h . Also, other walls are insulated. It is found that the heat transfer is increased via increasing the Hartmann and Reynolds numbers. For low Reynolds numbers, the enhances of the Hartman number leads to a slightly increases of the average Nusselt number, but for high Reynolds numbers, the average Nusselt number gets an ascending trend and the increase in the Hartmann number shows its effect more pronounced. Also, with increase in Ri, the effect of nanofluid on the heat transfer increases. Due to practical impotence, the study of mixed convection heat transfer in enclosures and various shaped of cavities has attracted remarkable attentions in the past few decades. Significant applications of the mixed convection flow can be found in atmospheric flows, solar energy storage, heat exchangers, lubrication technology, drying technologies, cooling of the electronic devices, etc. The present results are original and new for the problem of MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid. Comparison of the obtained results with those from the open literature (Mahmoodi et al. [24]) is acceptable.

  19. The Effects of Spatial Enclosure on Social Interaction Between Older Adults With Dementia and Young Children.

    PubMed

    Cerruti, Minyoung S; Shepley, Mardelle M

    2016-04-01

    To examine the impact of spatial enclosures on social interaction between older adults with early stage dementia and young children. Intergenerational interaction through meaningful activities can promote positive affects and behaviors of children and older adults. The development of social interaction is closely related to the physical environment in association with personal competence of older adults with dementia and young children. However, minimal attention has been given to the role of physical environment in influencing intergenerational interaction. A quasi-experiment examined the functional relationship between the amount of spatial enclosure and the types of social behaviors of older adults with dementia and young children. Semi-structured interviews, aided by a photographic simulation, were developed to explore the participants' perceptions of and experiences with the different degrees of spatial enclosure. Findings showed that the semienclosed spatial plan impacted both prosocial and antisocial behaviors of older adults with dementia in their interactions with young children. This apparent discrepancy was associated with two conflicting perceptions: a sense of openness and the lack of control due to distraction created by the loose visual boundary. There was no correlation between the elder-child neutral behaviors and the degrees of spatial enclosure. This study suggests that spaces with moderate openness without visual and acoustic distraction are the most desirable to promote prosocial behaviors of older adults with dementia and young children. Additionally, elder-child prosocial behaviors were likely facilitated by specific design features such as adequate personal space, the perception of openness, and possible spaces that provide both prospect and refuge in relation to spatial enclosure. © The Author(s) 2016.

  20. Caenorhabditis elegans anillin (ani-1) regulates neuroblast cytokinesis and epidermal morphogenesis during embryonic development.

    PubMed

    Fotopoulos, N; Wernike, D; Chen, Y; Makil, N; Marte, A; Piekny, A

    2013-11-01

    The formation of tissues is essential for metazoan development. During Caenorhabditis elegans embryogenesis, ventral epidermal cells migrate to encase the ventral surface of the embryo in a layer of epidermis by a process known as ventral enclosure. This process is regulated by guidance cues secreted by the underlying neuroblasts. However, since the cues and their receptors are differentially expressed in multiple cell types, the role of the neuroblasts in ventral enclosure is not fully understood. Furthermore, although F-actin is required for epidermal cell migration, it is not known if nonmuscle myosin is also required. Anillin (ANI-1) is an actin and myosin-binding protein that coordinates actin-myosin contractility in the early embryo. Here, we show that ANI-1 localizes to the cleavage furrows of dividing neuroblasts during mid-embryogenesis and is required for their division. Embryos depleted of ani-1 display a range of ventral enclosure phenotypes, where ventral epidermal cells migrate with similar speeds to control embryos, but contralateral neighbors often fail to meet and are misaligned. The ventral enclosure phenotypes in ani-1 RNAi embryos suggest that the position or shape of neuroblasts is important for directing ventral epidermal cell migration, although does not rule out an autonomous requirement for ani-1 in the epidermal cells. Furthermore, we show that rho-1 and other regulators of nonmuscle myosin activity are required for ventral epidermal cell migration. Interestingly, altering nonmuscle myosin contractility alleviates or strengthens ani-1's ventral enclosure phenotypes. Our findings suggest that ventral enclosure is a complex process that likely relies on inputs from multiple tissues. © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of direct-exchange areas for a cylindrical enclosure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sika, J.

    1991-11-01

    This paper reports on a method for calculating the radiative heat transfer direct-exchange areas for surface-to-surface, volume-to-surface, and volume-to-volume pairs of zones in axisymmetric cylindrical geometries. With this method the calculation of the direct-exchange areas can be transformed from the original four-, five-, and sixfold integrals in the defining relations to just single and/or double integrals. Gray gas with absorption coefficient K is assumed.

  2. 9 CFR 3.31 - Sanitation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Pigs and Hamsters Animal Health and Husbandry Standards § 3.31 Sanitation. (a) Cleaning and sanitation... foods, or moisture condensation, the guinea pigs or hamsters shall be transferred to clean primary enclosures. (3) Prior to the introduction of guinea pigs or hamsters into empty primary enclosures previously...

  3. 46 CFR 193.15-35 - Enclosure openings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces which are protected by carbon dioxide extinguishing systems provisions... to that space. (b) Where natural ventilation is provided for spaces protected by a carbon dioxide...

  4. 30 CFR 56.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Grounding circuit enclosures. 56.12025 Section 56.12025 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity...

  5. 30 CFR 56.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Grounding circuit enclosures. 56.12025 Section 56.12025 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity...

  6. 30 CFR 56.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Grounding circuit enclosures. 56.12025 Section 56.12025 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity...

  7. 30 CFR 56.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding circuit enclosures. 56.12025 Section 56.12025 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity...

  8. 30 CFR 56.12025 - Grounding circuit enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Grounding circuit enclosures. 56.12025 Section 56.12025 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity...

  9. 46 CFR 193.15-35 - Enclosure openings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces which are protected by carbon dioxide extinguishing... carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the...

  10. 46 CFR 193.15-35 - Enclosure openings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces which are protected by carbon dioxide extinguishing... carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the...

  11. 32 CFR Enclosure 1 - Requirements for Environmental Considerations-Global Commons

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Requirements for Environmental Considerations... ENVIRONMENT ENVIRONMENTAL EFFECTS ABROAD OF MAJOR DEPARTMENT OF DEFENSE ACTIONS Information requirements. Pt. 187, Encl. 1 Enclosure 1—Requirements for Environmental Considerations—Global Commons A. General. This...

  12. 32 CFR Enclosure 1 - Requirements for Environmental Considerations-Global Commons

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Requirements for Environmental Considerations... ENVIRONMENT ENVIRONMENTAL EFFECTS ABROAD OF MAJOR DEPARTMENT OF DEFENSE ACTIONS Information requirements. Pt. 187, Encl. 1 Enclosure 1—Requirements for Environmental Considerations—Global Commons A. General. This...

  13. 9 CFR 3.53 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... used at research facilities when approved by the Institutional Animal Care and Use Committee, and by... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits... enclosures shall be constructed so as to protect the rabbits' feet and legs from injury. Litter shall be...

  14. 9 CFR 3.53 - Primary enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... research facilities when approved by the Institutional Animal Care and Use Committee, and by dealers and... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits... enclosures shall be constructed so as to protect the rabbits' feet and legs from injury. Litter shall be...

  15. 9 CFR 3.53 - Primary enclosures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... used at research facilities when approved by the Institutional Animal Care and Use Committee, and by... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits... enclosures shall be constructed so as to protect the rabbits' feet and legs from injury. Litter shall be...

  16. 9 CFR 3.53 - Primary enclosures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... research facilities when approved by the Institutional Animal Care and Use Committee, and by dealers and... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits... enclosures shall be constructed so as to protect the rabbits' feet and legs from injury. Litter shall be...

  17. 9 CFR 3.53 - Primary enclosures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... used at research facilities when approved by the Institutional Animal Care and Use Committee, and by... WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment and Transportation of Rabbits... enclosures shall be constructed so as to protect the rabbits' feet and legs from injury. Litter shall be...

  18. 9 CFR 112.7 - Special additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... a biological product containing inactivated rabies virus, carton labels, enclosures, and all but... biological product containing modified live rabies virus, the carton labels, enclosures, and all but very... Any Other Animal!” (2) For other vaccines containing modified live rabies virus, the statement “For...

  19. 46 CFR 193.15-35 - Enclosure openings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces which are protected by carbon dioxide extinguishing systems provisions... to that space. (b) Where natural ventilation is provided for spaces protected by a carbon dioxide...

  20. 40 CFR 63.5875 - How do I determine the capture efficiency of the enclosure on my wet-out area and the capture...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lamination/casting operations? 63.5875 Section 63.5875 Protection of Environment ENVIRONMENTAL PROTECTION... lamination/casting operations? (a) The capture efficiency of a wet-out area enclosure is assumed to be 100...

  1. Gas tungsten arc welder

    DOEpatents

    Christiansen, D.W.; Brown, W.F.

    A welder for automated closure of fuel pins by a gas tungsten arc process in which a rotating length of cladding is positioned adjacent a welding electrode in a sealed enclosure. An independently movable axial grinder is provided in the enclosure for refurbishing the used electrode between welds.

  2. 9 CFR 3.28 - Primary enclosures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... for guinea pigs and hamsters shall conform to the following requirements: (a) General. (1) Primary enclosures shall be structurally sound and maintained in good repair to protect the guinea pigs and hamsters... be constructed and maintained so that the guinea pigs or hamsters contained therein have convenient...

  3. 75 FR 52213 - Cold Treatment Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... enclosure as adequate to allow for fruit pulp temperatures to be taken prior to beginning treatment. In... the treatment enclosure, an official authorized by APHIS must take pulp temperatures manually from a... cooled, followed by pulp temperature readings being taken in fruit throughout the pallet. While readings...

  4. Whole-tree canopy enclosures: why cage a tree?

    Treesearch

    Jerome F. Grant; Abdul Hakeem; Paris L. Lambdin; Gregory J. Wiggins; Rusty J. Rhea

    2011-01-01

    The use of whole-tree canopy enclosures (i.e., cages) is not a typical approach to assessing biological parameters and interactions in a forest setting. However, the successful application of this technology may enable researchers to better understand certain types of tree/organismal interactions.

  5. 9 CFR 3.31 - Sanitation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Pigs and Hamsters Animal Health and Husbandry Standards § 3.31 Sanitation. (a) Cleaning and sanitation... foods, or moisture condensation, the guinea pigs or hamsters shall be transferred to clean primary enclosures. (3) Prior to the introduction of guinea pigs or hamsters into empty primary enclosures previously...

  6. 9 CFR 3.31 - Sanitation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Pigs and Hamsters Animal Health and Husbandry Standards § 3.31 Sanitation. (a) Cleaning and sanitation... foods, or moisture condensation, the guinea pigs or hamsters shall be transferred to clean primary enclosures. (3) Prior to the introduction of guinea pigs or hamsters into empty primary enclosures previously...

  7. 9 CFR 3.31 - Sanitation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Pigs and Hamsters Animal Health and Husbandry Standards § 3.31 Sanitation. (a) Cleaning and sanitation... foods, or moisture condensation, the guinea pigs or hamsters shall be transferred to clean primary enclosures. (3) Prior to the introduction of guinea pigs or hamsters into empty primary enclosures previously...

  8. 50 CFR 14.131 - Primary enclosures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... same primary enclosure with an adult marine mammal other than its mother. Socially dependent animals (e... Wild Mammals and Birds to the United States Specifications for Marine Mammals (cetaceans, Sirenians..., harnesses, or other such devices used for body support or restraint when transporting marine mammals such as...

  9. Region 9: California Los Angeles - San Bernadino Counties Adequate Letter Enclosure (5/20/2008)

    EPA Pesticide Factsheets

    This document is the enclosure to the April 16, 2008, letter from EPA provides adequacy finding for transportation conformity purposes the motor vehicle emissions budgets in the Antelope Valley-Western Mojave Desert 8-hour Ozone Early Progress Plan.

  10. Device for accurately measuring mass flow of gases

    DOEpatents

    Hylton, J.O.; Remenyik, C.J.

    1994-08-09

    A device for measuring mass flow of gases which utilizes a substantially buoyant pressure vessel suspended within a fluid/liquid in an enclosure is disclosed. The pressure vessel is connected to a weighing device for continuously determining weight change of the vessel as a function of the amount of gas within the pressure vessel. In the preferred embodiment, this pressure vessel is formed from inner and outer right circular cylindrical hulls, with a volume between the hulls being vented to the atmosphere external the enclosure. The fluid/liquid, normally in the form of water typically with an added detergent, is contained within an enclosure with the fluid/liquid being at a level such that the pressure vessel is suspended beneath this level but above a bottom of the enclosure. The buoyant pressure vessel can be interconnected with selected valves to an auxiliary pressure vessel so that initial flow can be established to or from the auxiliary pressure vessel prior to flow to or from the buoyant pressure vessel. 5 figs.

  11. Analytical study of acoustic response of a semireverberant enclosure with application to active noise control

    NASA Technical Reports Server (NTRS)

    Parrott, T. L.; Schein, D. B.; Gridley, D.

    1985-01-01

    The acoustic response of a semireverberant enclosure with two interacting, velocity-prescribed source distributions was analyzed using standard modal analysis techniques with a view toward a better understanding of active noise control. Different source and enclosure dimensions, source separations, and single-wall admittances were studied over representative frequency bandwidths of 10 Hz with source relative phase as a parameter. Results indicate that power radiated into the enclosure agree qualitatively with the spatial average of the mean square pressure, even though the reverberant field is nondiffuse. Decreases in acoustic power can therefore be used to estimate global noise reduction in a nondiffuse semireverberant environment. As might be expected, parametric studies indicate that maximum power reductions of up to 25 dB can be achieved when secondary and primary sources are compact and closely spaced. Although less success is achieved with increasing frequency and source separation or size, significant suppression of up to 8 dB still occurs over the 1 to 2 Hz bandwidth.

  12. Device for accurately measuring mass flow of gases

    DOEpatents

    Hylton, James O.; Remenyik, Carl J.

    1994-01-01

    A device for measuring mass flow of gases which utilizes a substantially buoyant pressure vessel suspended within a fluid/liquid in an enclosure. The pressure vessel is connected to a weighing device for continuously determining weight change of the vessel as a function of the amount of gas within the pressure vessel. In the preferred embodiment, this pressure vessel is formed from inner and outer right circular cylindrical hulls, with a volume between the hulls being vented to the atmosphere external the enclosure. The fluid/liquid, normally in the form of water typically with an added detergent, is contained within an enclosure with the fluid/liquid being at a level such that the pressure vessel is suspended beneath this level but above a bottom of the enclosure. The buoyant pressure vessel can be interconnected with selected valves to an auxiliary pressure vessel so that initial flow can be established to or from the auxiliary pressure vessel prior to flow to or from the buoyant pressure vessel.

  13. Pressure Control System Design for a Closed Crop Growth Chamber

    NASA Technical Reports Server (NTRS)

    Tsai, K.; Blackwell, C.; Harper, Lynn D. (Technical Monitor)

    1994-01-01

    The Controlled Ecological Life Support System (CELSS) is an area of active research at NASA. CELSS is a plant-based bioregenerative life support system for long term manned space flights where resupply is costly or impractical. The plants in a CELSS will function to convert the carbon dioxide (exhaled by the crew) into oxygen, purify non-potable water into potable quality water, and provide food for the crew. Prior to implementing a CELSS life support system, one must have knowledge on growing plants in a closed chamber under low gravity. This information will come from research to be conducted on the CELSS Test Facility that will operate on the Space Station Freedom. Currently a ground-based CELSS Test Facility is being built at NASA Ames Research Center. It is called the EDU (Engineering Development Unit). This system will allow researchers to identify issues that may cause difficulties in the development of the CELSS Test Facility and aid in the development of new needed technologies. The EDU consists of a 1 m2 crop growth chamber that is surrounded by a containment enclosure. The containment enclosure isolates the system so there is very little mass and thermal exchange with the ambient. The leakage rate is on the order of 1 % of the enclosure's volume per day (with 0.2S psi pressure difference). The thermal leakage is less than 0.5% of the electrical power supplied to the system per degree Celsius difference from the surrounding. The pressure in the containment enclosure is regulated at 62.5 Pa below the ambient by an active controller. The goal is to maintain this set point for a variety of conditions, such as a range of operating temperatures, heat load variations that occur when the lights are turned on and off, and fluctuations in ambient pressure. In addition certain transition tracking performance is required. This paper illustrates the application of some advanced systems control methods to the task of synthesizing the EDU's pressure control system.

  14. Electrode for electrochemical cell

    DOEpatents

    Kaun, T.D.; Nelson, P.A.; Miller, W.E.

    1980-05-09

    An electrode structure for a secondary electrochemical cell includes an outer enclosure defining a compartment containing electrochemical active material. The enclosure includes a rigid electrically conductive metal sheet with perforated openings over major side surfaces. The enclosure can be assembled as first and second trays each with a rigid sheet of perforated electrically conductive metal at major side surfaces and normally extending flanges at parametric margins. The trays can be pressed together with moldable active material between the two to form an expandable electrode. A plurality of positive and negative electrodes thus formed are arranged in an alternating array with porous frangible interelectrode separators within the housing of the secondary electrochemical cell.

  15. Electrode for electrochemical cell

    DOEpatents

    Kaun, Thomas D.; Nelson, Paul A.; Miller, William E.

    1981-01-01

    An electrode structure for a secondary electrochemical cell includes an outer enclosure defining a compartment containing electrochemical active material. The enclosure includes a rigid electrically conductive metal sheet with perforated openings over major side surfaces. The enclosure can be assembled as first and second trays each with a rigid sheet of perforated electrically conductive metal at major side surfaces and normally extending flanges at parametric margins. The trays can be pressed together with moldable active material between the two to form an expandable electrode. A plurality of positive and negative electrodes thus formed are arranged in an alternating array with porous frangible interelectrode separators within the housing of the secondary electrochemical cell.

  16. Thermoluminescence dosimeter

    DOEpatents

    Zendle, R.

    1983-11-03

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  17. Particle capture device

    DOEpatents

    Jayne, John T.; Worsnop, Douglas R.

    2016-02-23

    In example embodiments, particle collection efficiency in aerosol analyzers and other particle measuring instruments is improved by a particle capture device that employs multiple collisions to decrease momentum of particles until the particles are collected (e.g., vaporized or come to rest). The particle collection device includes an aperture through which a focused particle beam enters. A collection enclosure is coupled to the aperture and has one or more internal surfaces against which particles of the focused beam collide. One or more features are employed in the collection enclosure to promote particles to collide multiple times within the enclosure, and thereby be vaporized or come to rest, rather than escape through the aperture.

  18. Heat treatment furnace

    DOEpatents

    Seals, Roland D; Parrott, Jeffrey G; DeMint, Paul D; Finney, Kevin R; Blue, Charles T

    2014-10-21

    A furnace heats through both infrared radiation and convective air utilizing an infrared/purge gas design that enables improved temperature control to enable more uniform treatment of workpieces. The furnace utilizes lamps, the electrical end connections of which are located in an enclosure outside the furnace chamber, with the lamps extending into the furnace chamber through openings in the wall of the chamber. The enclosure is purged with gas, which gas flows from the enclosure into the furnace chamber via the openings in the wall of the chamber so that the gas flows above and around the lamps and is heated to form a convective mechanism in heating parts.

  19. Thermoluminescence dosimeter

    DOEpatents

    Zendle, Robert

    1985-01-01

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  20. Life raft stabilizer

    NASA Technical Reports Server (NTRS)

    Radnofsky, M. I.; Barnett, J. H., Jr.; Harrison, F. L.; Marak, R. J. (Inventor)

    1973-01-01

    An improved life raft stabilizer for reducing rocking and substantially precluding capsizing is discussed. The stabilizer may be removably attached to the raft and is defined by flexible side walls which extend a considerable depth downwardly to one another in the water. The side walls, in conjunction with the floor of the raft, form a ballast enclosure. A weight is placed in the bottom of the enclosure and water port means are provided in the walls. Placement of the stabilizer in the water allows the weighted bottom to sink, producing submerged deployment thereof and permitting water to enter the enclosure through the port means, thus forming a ballast for the raft.

  1. 46 CFR 111.60-11 - Wire.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...

  2. 46 CFR 111.60-11 - Wire.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD... Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be component insulated. (c) Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and...

  3. Heat Entrapment Effects Within Liquid Acquisition Devices

    NASA Technical Reports Server (NTRS)

    Duval, W. M. B.; Chato, D. J.; Doherty, M. P.

    2010-01-01

    We introduce a model problem to address heat entrapment effects or the local accumulation of thermal energy within liquid acquisition devices. We show that the parametric space consists of six parameters, namely the Rayleigh and Prandtl numbers, the aspect ratio, and heat flux ratios for the bottom, side, and top boundaries of the enclosure. For the range of Ra considered 1 to 10(sup 9), beyond Ra on the order of 10(sup 5), convective instability is the dominant mode of convection in comparison to natural convection. The flow field transitions to asymmetric modes at Ra on the order of 10(sup 7). Direct numerical simulation of a large geometric length scale prototype for Ra on the order of 10(sup 9) shows that the flow field evolves from small wavelength instability which gives rise to nonlinear growth of thermals, propagation of the instability occurs via growth of secondary and tertiary modes, and a travelling wave mode occurs prior to asymmetry. The effect of a large aspect ratio is to increase the number of modes in the vertical direction. Due to the slow diffusion of heat in the prototype, asymptotic states are not readily attained, we show that dynamical similarity can be used for a model which allows the attainment of asymptotic states and that transition to a chaotic state occurs for Ra on the order of 10(sup 9) via a broadband power spectrum. These dynamical events show that for the baseline condition in which heat is absorbed from background laboratory environment, higher heat flux is absorbed at the top and bottom boundaries of the enclosure than a nominal value of 34.9 ergs per square centimeter -second.

  4. Role of habitat complexity in predator-prey dynamics between an introduced fish and larval Long-toed Salamanders (Ambystoma macrodactylum)

    USGS Publications Warehouse

    Kenison, Erin K; Litt, Andrea R.; Pilliod, David S.; McMahon, Tom E

    2016-01-01

    Predation by nonnative fishes has reduced abundance and increased extinction risk for amphibian populations worldwide. Although rare, fish and palatable amphibians have been observed to coexist where aquatic vegetation and structural complexity provide suitable refugia. We examined whether larval long-toed salamanders (Ambystoma macrodactylum Baird, 1849) increased use of vegetation cover in lakes with trout and whether adding vegetation structure could reduce predation risk and nonconsumptive effects (NCEs), such as reductions in body size and delayed metamorphosis. We compared use of vegetation cover by larval salamanders in lakes with and without trout and conducted a field experiment to investigate the influence of added vegetation structure on salamander body morphology and life history. The probability of catching salamanders in traps in lakes with trout was positively correlated with the proportion of submerged vegetation and surface cover. Growth rates of salamanders in enclosures with trout cues decreased as much as 85% and the probability of metamorphosis decreased by 56%. We did not find evidence that adding vegetation reduced NCEs in experimental enclosures, but salamanders in lakes with trout utilized more highly-vegetated areas which suggests that adding vegetation structure at the scale of the whole lake may facilitate coexistence between salamanders and introduced trout.

  5. Volatile Organic Compound Emissions by Agricultural Crops

    NASA Astrophysics Data System (ADS)

    Ormeno, E.; Farres, S.; Gentner, D.; Park, J.; McKay, M.; Karlik, J.; Goldstein, A.

    2008-12-01

    Biogenic Volatile Organic Compounds (BVOCs) participate in ozone and aerosol formation, and comprise a substantial fraction of reactive VOC emission inventories. In the agriculturally intensive Central Valley of California, emissions from crops may substantially influence regional air quality, but emission potentials have not been extensively studied with advanced instrumentation for many important crops. Because crop emissions may vary according to the species, and California emission inventories are constructed via a bottom-up approach, a better knowledge of the emission rate at the species-specific level is critical for reducing uncertainties in emission inventories and evaluating emission model performance. In the present study we identified and quantified the BVOCs released by dominant agricultural crops in California. A screening study to investigate both volatile and semivolatile BVOC fractions (oxygenated VOCs, isoprene, monoterepenes, sesquiterpenes, etc.) was performed for 25 crop species (at least 3 replicates plants each), including branch enclosures of woody species (e.g. peach, mandarin, grape, pistachio) and whole plant enclosures for herbaceous species (e.g. onion, alfalfa, carrot), through a dynamic cuvette system with detection by PTRMS, in-situ GCMS/FID, and collection on carbon-based adsorbents followed by extraction and GCMS analysis. Emission data obtained in this study will allow inclusion of these crops in BVOC emission inventories and air quality simulations.

  6. 78 FR 54951 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-06

    .... The subject cars and their type, capacities, reporting marks, and other features are listed in an enclosure with the petition letter. Also included in the enclosure are the design, type, components, or... tourist attractions and historical purposes and will not be interchanged in regular freight operations...

  7. 30 CFR 75.819 - Motor-starter enclosures; barriers and interlocks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Motor-starter enclosures; barriers and interlocks. 75.819 Section 75.819 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High...

  8. 10 CFR 431.383 - Enforcement process for electric motors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... general purpose electric motor of equivalent electrical design and enclosure rather than replacing the... equivalent electrical design and enclosure rather than machining and attaching an endshield. ... sample of up to 20 units will then be randomly selected from one or more subdivided groups within the...

  9. 30 CFR 7.302 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... conduit box when specified. A motor assembly is comprised of one or more explosion-proof enclosures. Plane.... A metallic enclosure used as a winding compartment, conduit box, or a combination of both that... portions. Stuffing box. An entrance with a recess filled with packing material for cables extending through...

  10. 30 CFR 7.302 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... conduit box when specified. A motor assembly is comprised of one or more explosion-proof enclosures. Plane.... A metallic enclosure used as a winding compartment, conduit box, or a combination of both that... portions. Stuffing box. An entrance with a recess filled with packing material for cables extending through...

  11. 30 CFR 7.302 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... conduit box when specified. A motor assembly is comprised of one or more explosion-proof enclosures. Plane.... A metallic enclosure used as a winding compartment, conduit box, or a combination of both that... portions. Stuffing box. An entrance with a recess filled with packing material for cables extending through...

  12. 46 CFR 95.15-35 - Enclosure openings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  13. 46 CFR 76.15-35 - Enclosure openings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Carbon Dioxide Extinguishing Systems, Details § 76.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  14. 46 CFR 95.15-35 - Enclosure openings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  15. 46 CFR 76.15-35 - Enclosure openings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Carbon Dioxide Extinguishing Systems, Details § 76.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  16. 46 CFR 76.15-35 - Enclosure openings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Carbon Dioxide Extinguishing Systems, Details § 76.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  17. 46 CFR 95.15-35 - Enclosure openings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  18. 46 CFR 76.15-35 - Enclosure openings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Carbon Dioxide Extinguishing Systems, Details § 76.15-35 Enclosure openings. (a) Where mechanical ventilation is provided for spaces other than cargo and similar spaces which are protected by a carbon dioxide... protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively...

  19. Enclosure from DOE letter dated 7/20/07 - Table 5-2, Isotopic Compositions of Rocky Flats Plutonium and Uranium

    EPA Pesticide Factsheets

    This enclosure from a DOE letter to EPA regarding a waste container disposed at the WIPP from the Advanced Mixed Waste Treatment Project includes Table 5-2, Isotopic Compositions of Rocky Flats Plutonium and Uranium.

  20. 40 CFR 86.156-98 - Calculations; refueling test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of the net hydrocarbon mass change and methanol mass change (if applicable) in the enclosure is used... methanol (if applicable) concentrations in ppm carbon, initial and final enclosure ambient temperatures... standard shall be computed by dividing the total refueling mass emissions by the total gallons of fuel...

Top